Concealite Life Safety SS2000 Sensor Control Switch User Manual SpaceStation2000 Installation Final3
Concealite Life Safety Products Sensor Control Switch SpaceStation2000 Installation Final3
Users Manual
TM Phone: 605.542.4444 concealite.com Installation Instructions SpaceStation Occupancy Lighting Control System Please Save These Instructions Important Safeguards Read and Follow All Safety Instructions SpaceStation TM Do not use outdoors. þ þ Do not let power supply cords touch hot surfaces. þ Do not mount units where they will be exposed to direct sunlight, radiators, gas or electric heaters. Prolonged exposure to temperatures exceeding 95 degrees Fahrenheit may reduce battery life and void warranty. þ Equipment should be mounted securely in locations and at heights where it will not be readily subjected to tampering by unauthorized personnel. þ The use of accessory equipment not recommended by the MANUFACTURER may cause an unsafe condition. þ The AC voltage rating of this equipment is specified on the product label. Do not connect equipment to any other voltage. þ Do not use this equipment for other than its intended purpose. þ Servicing of this equipment should be performed by qualified service personnel. TECHNICAL DATA Model: Ac Supply Voltage: Maximum Load: Operating Voltage: Switched Power: Standby Power: Hold Time: Daylight Threshold Sensor Principle: Microwave Frequency: Microwave Power: Detection Range: Detection Angle: Mounting Height: Operating Temperature: IP Rating: SS2000 120/277 Volts (+/- 10%) 120v/400w 230v/1000w 277v/1200w Maximum Ballast Load 50/60hz, 120-277v +/- 10% 400w/1000w/1200w 0.6w (standby), 1.2w (operation) 10 / 30 / 50 / 75 100%, Can Be Customized 5s / 30s / 180s /300s /15min / 25min, Can Be Customized OPTIONAL: 20FC - 300FC Daylight / Twilight / Darkness, Can Be Customized Microwave Motion Detector 5.8 Ghz +/- 75mhz <1mw Max. (0 X H): 8m X 10m 02° 150° 0.5 - 100m -35°c `- +70°c IP 20 (mounting inside a lamp); IP 65 (mounting in special box) Copyright© Concealite Life Safety Products. All Rights Reserved. Specifications Subject to Change. GREENTECHNOLOGY SpaceStation sensors can be configured to operate with any number of sensors and control any number of lighting circuits as one system for any sized room application. Index Important Safeguards Sensor Mounting Sensor Adjustments New Construction/Retrofit Single Wiring Multiple Wiring Adjustable Remote Mounting (ARM) Troubleshooting Limited Warranty All Concealite fixtures are tested and are guaranteed to be free from defective materials and workmanship for a period of three years from date of shipment under normal operations and proper use. Correction of all defects shall be by replacement or repair (at our discretion) and shall constitute fulfillment of all manufacturer's obligations. We will not allow any charge for labor, materials, etc. that does not have our written approval before the work is begun. Damage incurring in handling or in transit are not covered by this guarantee. Any other warranty, expressed or implied, is hereby void. Modifications to the product or failure to follow installation instructions will void the warranty. v.092611–SS TM Instructions SpaceStation Phone: 605.542.4444 INSTALLATION | Sensor Mounting WARNING: to avoid fire, shock/electrocution, or injury – TURN OFF POWER at circuit breaker or fuse and test to ensure that power is off before wiring. Remove and discard the packaging materials. Failure to follow published installation instructions or any modifications to the product may damage the unit and will void the warranty. Area Sensitivity Adjustment (SpaceStation Centered in Room) Note: Maximum 60' Height Provides Maximum Range Coverage to 50 x 50 Feet ROOM WIDTH ROOM LENGTH Ceiling Height 8 Feet 10 Feet 12 Feet Adjustable Range Control Panels (RCP) controls exact cut off range of each room Room Area Range Coverage at Sensitivity % Setting 10% 35% 50% 75% 100% 7' 8' 9' 12' 7' 8' 9' 12' 20' 9' 10' 13' 17' 22' 9' 10' 13' 17' 22' 8' 9' 12' 20' 25' 8' 9' 12' 20' 25' 20' Step 1: Sensor Mounting A. Determine mounting location within room or area to be covered. Center the sensor within the center of the room/area when possible. Loosen front knobs. Loosen Front Knobs to Slide Panels B. Slide to adjust the four (4) room control panels to the distance indicated to match the distance in feet between the sensor and each of the room wall (to allow activation from any movement within that room area). Slide All Four Panels to the Match the Distance in Feet Between Sensor and Room Walls v.092611–SS i TM Instructions SpaceStation Phone: 605.542.4444 INSTALLATION | Sensor Adjustments WARNING: to avoid fire, shock/electrocution, or injury – TURN OFF POWER at circuit breaker or fuse and test to ensure that power is off before wiring. Remove and discard the packaging materials. Failure to follow published installation instructions or any modifications to the product may damage the unit and will void the warranty. STEP 2: SENSOR ADJUSTMENTS A. Detection Area Detection are can be reduced by selecting the combination on the DIP switches to fit precisely for each specific application. B. Hold Time Hold-time means the time period you would like to keep the lamp on after the person has left the detected area. C. Daylight Sensor (Remote Option Only) The sensor contains a daylight sensor in order to allow a function only below a defined brightness threshold. Sensor Adjustments DETECTION AREA II III IV 100% 75% 50% 30% 10% ON HOLD TIME II 180 S III 300 S IV 15 MIN V II III IV VI BRIGHTNESS THRESHOLD SETUP – DAYLIGHT SENSOR 5S 30 S DAYLIGHT: The lamp works always, even during daylight. 2O FC 5O FC 200 FC 300 FC DISABLE Note: Three switches should be put in OFF position when remote day light sensor is not installed. 25 MIN ON ON v.092611–SS TM Instructions SpaceStation Phone: 605.542.4444 INSTALLATION | New Construction & Retrofit WARNING: to avoid fire, shock/electrocution, or injury – TURN OFF POWER at circuit breaker or fuse and test to ensure that power is off before wiring. Remove and discard the packaging materials. Failure to follow published installation instructions or any modifications to the product may damage the unit and will void the warranty. Accessible Ceiling Installation: T-Bar Option - Suspended Accessible Ceilings Note: Use optional T-bar bracket for support mounting to inverted T-grid lay in suspended ceilings. Inccessible Ceiling Installation: ARM Option - Gypsum Board and Other Inaccessible Ceilings Note: Use Optional arm bracket for support mounting to structural blocking or stud also for retrofit installation through existing ceiling hole (see page 8 also). ARM Adjustable Remote Mounting to structural / blocking to secure SpaceStation v.092611–SS i TM Instructions Power Connections Phone: 605.542.4444 INSTALLATION | Single Wiring Control Wiring Diagram WARNING: to avoid fire, shock/electrocution, or injury – TURN OFF POWER at circuit breaker or fuse and test to ensure that power is off before wiring. Remove and discard the packaging materials. Failure to follow published installation instructions or any modifications to the product may damage the unit and will void the warranty. Red - Line Output to Load White - Neutral Black - Line Input STEP #3: Provide Power Connections Branch circuit: building power only connections. Provide 120 VAC or 277 VAC uninterrupted power connections to terminate within the ceiling mounted bracket junction box. A Option (OR) Single Lighting Circuit Control Wiring Diagram A – Optional B – Optional C – Load Information Optional: Override FDP Concealed Wall Switch Line Input Black Neutral Load Output Line Black Neutral White Load Red Blue Yellow Option (RDS) Optional: Remote Daylight Sensor SpaceStation Occupancy Sensor C Load Load must not exceed 800 watts @ 120 VAC. Load must not exceed 1200 watts @ 277 VAC. Loads in excess must use the Command Module option for higher wattage. Note: Dimming ballast circuits must be controlled by the Command Module option. v.092611–SS i TM Instructions Power Connections Phone: 605.542.4444 INSTALLATION | Multiple Wiring Control Wiring Diagram WARNING: to avoid fire, shock/electrocution, or injury – TURN OFF POWER at circuit breaker or fuse and test to ensure that power is off before wiring. Remove and discard the packaging materials. Failure to follow published installation instructions or any modifications to the product may damage the unit and will void the warranty. Multiple Lighting Circuit Control Wiring Diagram *Required for two or more circuits A – Optional B – Optional C – Load Information D – Command Module Information Line Input Neutral White Line Black Neutral White Neutral Blue Yellow A Option (OR) Optional: Override FDP Concealed Wall Switch Option (RDS) Optional: Remote Daylight Sensor Load Output Red SpaceStation Occupancy Sensor C Load Load must not exceed 800 watts @ 120 VAC. Load must not exceed 1200 watts @ 277 VAC. Loads in excess must use the Command Module option for higher wattage. Module (CM) – # of poles D Command i.e. CM04 - 4 lighting circuit poles ATTENTION! Verify line voltage is compatible with electrically held coil voltage (120 VAC or 277 VAC) § Dimming ballast circuits must be controlled by the Command Module option. TWO OR MORE SENSORS OPERATING TOGETHER § Parallel connect multiple (two or more) sensors for areas Specified: # of 20 AMP Circuits exceeding range coverage of one lighting sensor. v.092611–SS i TM Instructions Power Connections Phone: 605.542.4444 INSTALLATION | Adjustable Remote Mounting (ARM) WARNING: to avoid fire, shock/electrocution, or injury – TURN OFF POWER at circuit breaker or fuse and test to ensure that power is off before wiring. Remove and discard the packaging materials. Failure to follow published installation instructions or any modifications to the product may damage the unit and will void the warranty. ARM – Adjustable Remote Mounting Provide flexible conduit connections to existing Lighting Branch Circuit Existing Ceiling Opening ARM Adjustable Remote Mounting to structural / blocking to secure SpaceStation The minimum size opening is 4 inches in diameter for insertion of SpaceStation into an inaccessible ceiling opening Lighting Branch Circuit Lighting Branch Circuit Space Station Sensor Existing Light Fixture, J Box or Access panel Existing Ceiling Note: Dimming ballast circuits must be controlled by the Command Module option. v.092611–SS TM Instructions Troubleshooting Phone: 605.542.4444 Troubleshooting Time Delay IMPORTANT START-UP INFORMATION The first time the sensor is powered-up the load will flash ON then OFF once, then there will be 10 seconds while the sensor warms-up. The SpaceStation automatically turns OFF the load after the coverage area has been vacant for the amount of time set in the time delay. The minimum setting is 10 seconds, maximum is 30 minutes. TROUBLESHOOTING Quick Test: Turn the time delay to minimum. Move out of the sensor's view. Lights should turn OFF after 10 seconds. Move into the sensor's view. The lights should turn ON. Lights do not turn OFF: 1. If there is no motion in the set coverage area, reduce the sensitivity varying room panel adjusted positions. 2. Verify room panel adjustment positions. 3. Verify time delay and that there is no movement within the sensor's view for that time period. FCC NOTICE This device complies with part 15 of the FCC Rules, Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Warranty All Concealite fixtures are tested and are guaranteed to be free from defective materials and workmanship for a period of three years from date of shipment under normal operations and proper use. Correction of all defects shall be by replacement or repair (at our option) and shall constitute fulfillment of all manufacturer's obligations. We will not allow any charge for labor, materials, etc that does not have our written approval before the work is begun. Damage incurring in handling or in transit are not covered by this guarantee. Any other warranty, expressed or implied, is hereby void. Modifications or changes to the product or failure to follow installation instructions will void the warranty. v.092611–SS
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : Yes Encryption : Standard V2.3 (128-bit) User Access : Print, Extract, Print high-res Page Count : 8 XMP Toolkit : XMP toolkit 2.9.1-13, framework 1.6 About : uuid:e7844bd5-8f0d-4eac-ab8e-14a40dd50e63 Producer : Corel PDF Engine Version 14.0.0.701 Create Date : 2011:09:28 10:20:56-05:00 Creator Tool : CorelDRAW Modify Date : 2012:01:05 09:38:08-08:00 Metadata Date : 2012:01:05 09:38:08-08:00 Document ID : uuid:7f9771ee-1813-45e5-b09a-6ef46cee66b6 Instance ID : uuid:6de69c56-54f9-43c4-8274-b1318dd771ee Format : application/pdf Creator : Concealite Title : SpaceStation2000 Installation Final3 Author : ConcealiteEXIF Metadata provided by EXIF.tools