Controlled Entry Distributors REATSHE CARD READER User Manual
Controlled Entry Distributors, Inc. CARD READER Users Manual
Users Manual
4. Specifications Name Standalone Proximity Reader Infrared remote control Manager card Short Pin User manual Self Tapping Screws Specification W2 One for add, one for delete Used for factory default setting W2 3.5*27mm Quantity 4/2 2.Description The W2 is fully waterproof Proximity stand alone access Reader, which uses advanced microprocessor, equipped with large capacity Flash memory, supports up to 10 000 cards. It is so easy to add or delete card users by using the master card, besides, with Infrared remote control programmer, the user can set the features by themselves, including Alarm, Self-protection, interlock and Antisubmarine back Function. In additional, with infrared remote control programmer, you can add or delete cards directly by inputting card number The W2 not only has the features of low power consumption, automatic selection of lock ,anti vandal alarm and exit button, but also has the protective functions against input over voltage and outputs short-circuit. These features make the W2 safe , reliable and easy in operation. It is an idea choice for door access. Can be used as salve reader 2 pcsW2 can be interconnected/ interlocked Can be used as controller by connection slave reader Anti-submarine back Function Alarm signal output, Door open detection Full of 10000 users,recognizing speed <15ms. W2 D0 Green D1 White Drill holes on the wall or prepare the cassette. Wire through the hole, and blanket the unused cable in case of short circuit. Fix the back cover firmly on the cassette or the wall. Attach the reader to the back cover. OPEN Yellow Brown +12V Red GND VSS L- L+ ALARM+ Orange 4-low level 5-high level when alarm, the I/O outputs high level. L+ D6 ALARML- I/O I/O R7 Q6 R8 Q2 R20 R19 Figure 1 Note: The above diagrams show the output interface circuits. Do not power on until all wiring has been completed No 10 Color Green White Grey Yellow Brown Red Black Blue Purple Orange J1 Function D0 D1 ALARM+ OPEN D_IN 12V GND VSS LL+/Alarm+ Description Wiegand output, input signal wire D0 Wiegand output, input signal wire D1 connecting to the negative pole of the alarm equipment To connect to one part of Exit Button Door Contact input (+) 12Vdc Positive Regulated Power Input (-) Negative Regulated Power Input the negative pole of the controller, connect to the other part of Exit button and door contact Connect to the negative pole of the Lock Connect to the positive pole of the lock and alarm equipment Operation status Reset to factory default setting Sleeping mode Operation successful Enter into programming mode Enter into setting Exist from programming mode Operation failed Open the door Alarm D0 Green D1 White ALARM- Yellow D_IN Brown +12V Red GND Black LL+ ALARM+ LED Orange Red shines slow Red shines Orange shines Red shines slow Green shines Red shines fast Buzzer Two short ring Short ring Short ring Short ring Short ring Three short ring Short ring Alarm 10.1User settings There are 2 ways to add and delete users: B - By remote control A - By Manager card(The most convenient way) 8.To Reset to Factory Default and Manager Card setting Remarks: Reset to factory default setting, the users' information enrolled is still retained. When reset to Factory setting, the two Manager cards must be re-enrolled. .4. Manager add card Read user card Manager To Add user by Manager Card To Delete User by Manager Card Alarm DC12V/3A + - add card Cards can be added continuously. Manager delete card Read user card Manager Delete ca rd Cards can be deleted continuously. door detecting switch Blue Purple Orange Special Power Supply * Manager Password # 888888 is the default factory master code Remarks: All the steps below must be done after enter into programming mode To change the master code 0 New Password # Repeat New Password # The master code must be 6 8 digit number. To add a card user (Method 1) This is the faster way to enter cards using ID number auto generation. The card can be either be presented or input the 8 digit card number from the card can be manually entered 1 Read Card # or 1 Input Card number (8 digit) # Card can be added continuously without exiting programming mode. The card number is the last 8 digits of the number printing on the card. To add a card user(Method 2) This is the alternative way to enter cards using User ID Allocation. In this method a User ID is allocated to a card. Only one user ID can be allocated to a single card. 1 ID number # Read Card # or 1 ID number # the Card number (8 digits) # To delete a card user by card Number. Note users canbe deleted continuously without exiting programming mode Read Card # or Card number # 0000 To delete ALL users. (Note: This option will delete all users but Manager Cards. Be careful with use) Enter into the programming mode firstly B- By Remote control .5. PUSH NC COM NO Grey OPEN VSS Exit button .3. 10. W2 Detailed Programming Guide A - By manager card; Power off, use the supplied Contact Pin to short out the 2P socket on the mainboard, then power on, if successful, the beeper will beep twice, the LED shines in orange, remove the Short Pin, then read any two EM cards, after that the LED turns in red, means reset to factory default setting successfully. Of the two EM cards read, the first one is Manager add card, the second one is Manager delete card. Lock 40mm 9. Sound and Light indication +12V Blue Purple To Enter the programming mode By programme setting, I/O switch between low level and high level. Black .2. Alarm Interface Principle: Lock Interface Principle: DC12V/3A Grey D_IN 6. Wiring .1. 7. Interface Circuits Alarm door detecting switch Shielded cables Exit button ALARM- 5. Installation Common Power Supply J1 Fail-safe lock Standalone Card Reader Use capacity: 10,000 Card interface: 125KHZ EM card Remote control for programming With Manager cards for fast add and delete users Wiegand26 input/output 20% 98% Max20A Max20A Two 103*48*23mm Fail-securelock 3.Features Connection Diagram Humidity Lock output load Alarm output load Manager card Dimensions DC12V 10% <15mA 125KHZ EM card 5 10cm Wiegand 26 -20 60 61mm 1. Packing List Supply Voltage Sleeping Current Card type Card Reading Distance Wiegand interface Temperature 95.5mm W2 - Waterproof Standalone Proximity Reader .6. 10.2 Door setting Lock Power Setting Fail secure (Unlocked when power on) 4 0 99 # 0-99 is to setthe door relay time0-99 seconds. Fail safe (unlocked whenpower is off) This is the factorydefault, 5 seconds: 5 0 99 # 0-99 is to setthe door relay time0-99 seconds. Reader Lockout 7 1 Alarm Output 7 2 Anti-submarine Disabled 3 0 # Anti-submarine Master Mode: 3 1 # Antisubmarine Auxiliary Mode 3 2 # Door interlock disabled 8 0 To enable door open detection Advanced application ) . Read er Lockout & Alarm Output options. If there are 10 invalid cards in a 10 minute period, the Reader will lockout for 10 minutes or the alarm will operate for 10 minutes, depending on the option selected below. Normal status (No lockout or alarm) 7 0 8 1 9 0~3 # (Factory default setting) Power indoor White Toremove the doorforced open warning Read valid card or Master Code # To remove the door open too long warning Close the door or Read valid card J1 Green D0 White D1 D1 White White D1 ALARM- Grey D_IN D_IN Brown +12V Red Red GND Black Black GND VSS Blue Blue VSS Purple L- Orange L+ ALARM+ Exit button Orange Lock W2 controller 1 Yellow Alarm 2 Alarm 1 door detecting switch 1 Exit button 2 Exit button 1 Grey ALARM- Yellow OPEN Brown D_IN Red +12V door detecting switch 2 GND Black Black GND VSS Blue Blue VSS Purple L- Orange L+ ALARM+ L- Purple J1 Green +12V L- D0 Red L+ ALARM+ Door 2 D0 Brown +12V Power DC12V/3A Door 1 Green Alarm door detecting switch Purple Orange Lock L+ ALARM+ Purple Orange J1 D0 Green D0 D1 White D1 GND Controller Powerful supply Grey ALARM- Yellow OPEN Brown D_IN Red +12V Black GND Blue VSS Purple Orange Controller with wiegand 26 input LL+ ALARM+ figure 2 W2 .8. W2 controller 2 W2 controller 1 J1 OPEN Brown Blue +12V 4. Two W2 units interconnected & interlocked for 2 doors In this mode two W2 units are used for a two doors which are then interconnected and interlocked. In this mode the doors can be interlocked so that when door 1 is open, door 2 cannot be opened, and vise versa. The interlocked function is mainly used in banks, prisons, and other places where a higher level of security is required. See figure 4 ALARM- D_IN Black VSS Alarm door detecting switch Exit button Read user card (Note that Manager Card can't be used to unlock the door.) 1. W2 operating as a Controller In this mode the W2 supports a Wiegand 26 bit input so an external Wiegand device with a 26 bit output can be connected to the Wiegand input terminals on the W2. Either an ID card reader (125 KHZ) or an IC card reader (13.56MHZ) can be connected to the W2. Cards are required to be added at the external reader, except where an external EM reader is used, in this case cards can be added at either reader. See figure 1 OPEN Yellow 2. W2 operating as a Wiegand Output Reader In this mode the W2 supports a Wiegand 26 bit output so the Wiegand data lines can be connected to any controller which supports a Wiegand 26 bit input. See figure 2 or Master Code # To Unlock the door Yellow Grey OPEN D0 reader plug To Unlock the door Grey ALARM- GND figure 1 DC12V/3A J1 D1 outdoor Brown Red D1 Yellow +12V L- .7. 3. Two W2 units interconnected for a single door In this mode two W2 units are used for a single door, one for entry and the other for exit. Either device acts as the controller and reader at the same time. Users can be enrolled oneither of the devices. In this mode the user capacity for one door can be up to 20000. The setting of the two W2 units must be the same including the master code. See figure 3 Green +12V DC12V/3A Em card Ic card HID card Grey D_IN L+ ALARM+ .6. D0 Attach: Advanced Application Security Mode Setting Green White ALARM- To remove the alarm D0 D1 OPEN To set the alarm output time (0-3 minutes) Factory default is 1 minute Door open detection Door Open Too Long (DOTL) warning. When used with an optional magnetic contact or built-in magnetic contact of the lock, if the door is opened normally, but not closed after 1 minute, the inside buzzer will beep automatically to remind people to close the door and continue for 1 minute before switching off automatically. Door Forced Open warning. When used with an optional magnetic contact or built in magnetic contact of the lock, if the door is forced open, or if the door is opened after 120 seconds of the electro-mechanical lock not closed properly, the inside buzzer and alarm output will both operate. To disable door open detection. (Factory default) J1 Alarm output time (Factory default) (Note: the detailed wiring diagram and illustrate,please refer to the GND Door Interlock. Door interlock enabled Anti-submarine Settings Power wiegand reader W2 controller Lock 1 Lock 2 5. Anti-submarine function for single door (3 1 #) The connection diagram is as figure 1. Install one Wiegand reader (or a W2 without user information as reader) outside the door, connecting to one W2Controller inside the door, which acts as the Anti-submarine Master unit. Of the two devices, they build up an anti-submarine system for single door. The operation and function is as below: 5.1 Set the needed function and enroll the User Cards on the inside W2 - Antisubmarine Master unit. 5.2 With the valid user card, the user can only enter the door from the outside reader, and exit from the inside W2 Controller. On the other hand, without entering record from the reader, the user can't exit from the controller inside, also, the user can't enter in and exit twice continuously. 6. Anti-submarine function for 2 doors The connection diagram is as Figure 4. Door 1 with one W2, and Door 2 with one W2, set one W2 on Door 1 as the Anti-submarine Auxiliary unit (3 2 #), and set the other W2 on Door 2 as the Anti-submarine Master unit(3 1 #). They build up a two doors anti-submarine system, which is normally used for parking lot......etc The operation and function is as below: 6.1 Set the needed function and enroll the User Cards from W2 - Anti-submarine Master unit on Door 2. W2 controller 2 figure 4 6.2 With the valid user card, the user can only enter in from Door 1, and exit from Door 2. On the other hand, without entering record from the Auxiliary unit, the user can't exit from the Master unit or Auxiliary unit , also, the user can't enter in and exit twice continuously. .10. .11. figure 3 .9. FCC WARNING This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. NOTE 1: Any changes or modifications not expressly approved by the manufacturer could void the userâs authority to operate the equipment. NOTE 2: The manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications to this equipment. Such modifications could void the userâs authority to operate the equipment.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : No XMP Toolkit : 3.1-701 Create Date : 2010:12:11 11:19:49Z Creator Tool : CorelDRAW Version 9.397 Modify Date : 2011:03:03 09:37:46+08:00 Metadata Date : 2011:03:03 09:37:46+08:00 Format : application/pdf Creator : s Title : W2ÖÐÓ¢ÎÄ˵Ã÷Êé´òÓ¡°æ.cdr Producer : Corel PDF Engine Version 9.397 Document ID : uuid:8ff05aa6-baa2-4145-a667-ceb3604c6905 Instance ID : uuid:26f6ee77-c19d-45a2-8d0a-b50580969f87 Page Count : 3 Author : sEXIF Metadata provided by EXIF.tools