Controlled Entry Distributors SAM1000 ACCESS CONTROLS User Manual

Controlled Entry Distributors, Inc. ACCESS CONTROLS

USERS MANUAL

Download: Controlled Entry Distributors SAM1000 ACCESS CONTROLS User Manual
Mirror Download [FCC.gov]Controlled Entry Distributors SAM1000 ACCESS CONTROLS User Manual
Document ID907105
Application IDAyoO8Y5wxJqcW2YJVJYSXA==
Document DescriptionUSERS MANUAL
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize14.95kB (186837 bits)
Date Submitted2008-02-27 00:00:00
Date Available2008-02-27 00:00:00
Creation Date2008-02-22 13:58:56
Producing SoftwareAcrobat Distiller 7.0 (Windows)
Document Lastmod2008-02-22 13:58:56
Document TitleMicrosoft Word - User Manual.doc
Document CreatorPScript5.dll Version 5.2
Document Author: new

SEBURY
SAM-1000
Digital Keypad
Introduction
The SAM-1000 uses the latest microprocessor technology to operate door strikes
and security systems that require a momentary (timed) or latching dry contact
closure.
All programming is done through the keypad. Codes and operating parameters are
stored within the microprocessor and can not be lost due to power failure.
The SAM-1000 can store 1000 prox cards and user 4 digit codes. Each 4 digit code
has 10,000 possible combinations. The unit has one relay with 5 Amp contacts.
CONTENTS
Page
Introduction ……………………………………………………………. 2
Product Specifications …………………………………………………. 3
Intramural Interface Circuit…………………………………………….
Mounting & PCB Diagram ……………………………………………. 4
Wiring Diagram ………………………………………………………. 4-5
Engineer Programming Information and Notes …………………….. 5
Engineer Programming
Factory Default Setting ………………………………………….. 6
Changing Master & User Codes………………………………….. 7
Setting Functions of Master & User ……………………………. 7
Set Door Relay Strike ……………………………………………… 7
Set Door Open Detection Time …………………………………. 8
Security Arrangement ……………………………………………. 9
Exit Engineer Programming Mode ……………………………… 9
Resetting Non Volatile Memory ………………………………………. 9
Installer Information & Notes …………………………………………… 9
Technical Specifications ….…………………………………………… 10
Specifications
1.
Programmable Functions
Relay latching or momentary
Relay activate independently or together
Change Codes 1 master, 1000 users & prox cards
Door open detection
2.
Programmable Timers
Door relay time 00-99 seconds
Door open detection 00-99 seconds
Alarm time 00-99 minutes
3.
Wiring Connections
Electric lock
External bell
External Push Switch
Magnetic Contacts
Alarm
4.
Keypad:
12 keys
5.
Programming memory:
Non volatile Eeprom memory
IMPORTANT INFORAMTION
There are no user serviceable parts contained within the SAM-1000 access control
keypad.
If holes are to be drilled before mounting onto a wall, check for hidden cables and/or
pipes before drilling. Use safety goggles when drilling or hammering in cable clips.
Every effort has been made to provide accurate information, however slight variations
can occur. We also reserve the right to make changes for product improvement at
any time
NOTE
PLEASE READ THESE INSTRUCTIONS CAREFULLY BEFORE ATTEMPTING TO
INSTALL THE SAM-1000
Intramural Interface Circuit
1. Alarm output interface (See Figure 1)
2. Electric lock interface (See Figure 2)
Figure 1
Figure 2
Mounting
1. Attach the rear plate to a single or double gang electrical box or secure to the
wall firmly with at least three flat head screws.
2.
When wiring has been completed, attach the front cover to the rear plate.
Figure 3
Figure 4
The front cover can be permanently secured by using the short screw supplied
SAM-1000 Printed Circuit Board
Wiring
1. Unplug the cable harness and connect the necessary cables, (See Figure 5).
2. Tape any wires that are unused.
3. Plug the cable harness , (See Figure 5)
4. Attach the front cover, (See Figure 3).
Terminal Wire Connector 1 Function
10
Bell1
Bell2
12V
GND
COM
NO
NC
D_IN
OPEN
ALARM
White
White
Red
Black
Orange
Blue
Green
Brown
Yellow
Grey
Bell Push Button
Bell Push Button
(+) 12Vdc Positive Regulated Power Input
(-) Negative Regulated Power Input
Door Strike Relay Com
Door Strike Relay N/O
Door Strike Relay N/C
To Door Contact Then To Door In
To Door Remote Control Button Then Negative
Alarm
Warning! Do not plug adaptor our transformer into mains until all
wiring has been completed and the front cover secured.
Figure 5
Power Up
1.
After all wiring is complete and the unit face plate is attached to the back plate,
apply 12Vdc power to the unit. Accept LED(the yellow LED) flashing.
Engineer Programming Mode
To enter programming mode
Press:
* 9999 #
within 5 seconds, Ready(the green LED) and Accept LED
illuminated, Open LED flashing.
Note
Press: # to save changes and exit engineer programming, when all programming
has been completed otherwise changes will not be saved.
Changing Master & User Codes
In engineer programming mode:
To change Master code
Press: 0 new master code # re-enter new master code #
Upon acceptance Open LED illuminates and stops flashing. Press
after
changing the master code, otherwise unit will disregard the new code and revert back
to the factory default code.
Note: the master code must be 4-8 digit number.
Adding User Codes & Cards
To Add User cards & codes
Press: 1 read card user identification #
Note: the user identification must be 3 digit number, if adding more than 1 card, read
the next card after inputting the 3 digit code for the previous card, when you have
finished adding all cards press the # key. 1st card must be 000 up to 999.
Then the SAM-1000 control station added a user card it was auto added a user code
with 1234.
Delete User Card or Cards
There are 3 options to delete a user card or cards, in engineering mode.
a.) Press:
b.) Press:
c.) Press:
0 0 0 0 # to delete all user cards
read card # to delete individual user card
user identification number # to delete individual user card
User Operation Mode
There are 3 different options for user operation mode, card only, card and password,
valid code. The optioned used is common to all users.
Press:
Press:
Press:
00
01
02
valid card only
valid card and password
valid card or password
Setting Door Relay Strike Time
The door relay output can be operated as either normally opened or normally closed,
a maximum current of 10 ampere can pass through the relay if used as normally
opened or 5 ampere if normally closed. The door relay time can be set from 0
seconds to a maximum of 99 seconds. The factory default setting is 6 seconds and
can be changed through the keypad.
Press:
new time from 00-99 seconds
Setting Alarm Signal Output Time
Press:
new time from 00-99 minutes
Setting Door Open Detection
Press:
Press:
6 00
6 01
to disable this function (factory setting)
to enable this function.
In order for this feature to work, door contacts must be connected. There are 2
programming functions that work together in this mode.
a.) If door not closed after opening, keypad buzzer sounds.
b.) If door forced open, keypad buzzer sounds and sends alarm signal.
Setting Security Arrangement
There are two levels of keypad security available for the SAM-1000.
Press: 7 0 1
# to read 10 invalid cards or valid cards, then enter 4 wrong
passwords in succession, the keypad is locked for 10 minutes.
Press: 7 0 2
# to read 10 invalid cards or valid cards, then enter 4 wrong
passwords in succession, the keypad activates and alarm signal.
To disable this feature:
Press: 7 0 0 # factory default setting.
Resetting To Factory Default Setting
To revert all settings to the factory default values then the Non Volatile Memory
(Eeprom) must be reset.
Reset Non Volatile Memory by switching of the power and placing the jumper
connector onto the pins 1 & 2 as per figure 2. After switching power on remove
jumper, the SAM-1000 will give a beep and is now reset to factory default values.
Changing User Password Code
The factory default setting for each user password code 1234, this can be modified so
that each user has a unique individual 4 digit code.
Press: * read user card
new password #
user passoword
new password
re-enter
Using Password Code to release the door
Press: user passoword #
Technical Specification
DC Supply Voltage:
Current Consumption:
Door Relay:
Low voltage input 12 ±10% Vdc unregulated
100mA @ quiescent maximum
5Amp 12Vdc
Alarm output load:
Tamper Protection:
Codes :
Keypad:
Card Types:
Induction Distance:
Wiring Connections:
150mA pull current
Negative loop, normally closed
1 Master, 1000 cards and 1000 codes .
12 keys, 3 LED status indicators
EM or EM compatible
5-8cm
Electric lock
Remote door control
Door open detection
External door bell
External Alarm
Memory:
Operating Temperature:
Keypad Housing:
Dimensions:
Weight:
Non volatile eeprom memory
0°C to 60°C (32°F to 140°F)
Metal
128mm x 82mm x 28mm
500g
Package Listing
Name
Model no.
Quantity
Digital Keypad
SAM-1000
User Manual
SAM-1000
Flat Head Screws
Pastern Stopper
Self Tapping Screws
Remark
Φ3mm×6mm
Used for front case and back case
Φ6mm×27 mm
Used for fixing
Φ3.5mm×27 mm
Used for fixing
FCC WARNING
This device complies with Part 15 of the FCC Rules. Operation is
subject to the following
two conditions: (1) this device may not cause harmful interference,
and (2) this device must
accept any interference received, including interference that may cause
undesired operation.
The antenna provided is a unique antenna. By installation of
unauthorized antenna to this equipment. Such unauthorized
installation could void the user's authority to opearte the equipment.
NOTE: The manufacturer is not responsible for and radio or TV
interference caused by unauthorized modifications to this equipment.
Such modifications could void the user’s authority to operate the
equipment.
10

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
XMP Toolkit                     : 3.1-701
Producer                        : Acrobat Distiller 7.0 (Windows)
Creator Tool                    : PScript5.dll Version 5.2
Modify Date                     : 2008:02:22 13:58:56+08:00
Create Date                     : 2008:02:22 13:58:56+08:00
Format                          : application/pdf
Title                           : Microsoft Word - User Manual.doc
Creator                         : new
Document ID                     : uuid:b93410b0-1ad9-4fc1-8c4a-b1579335f813
Instance ID                     : uuid:60d959c3-19f2-4930-8b45-e6e063fa90c8
Page Count                      : 10
Author                          : new
EXIF Metadata provided by EXIF.tools
FCC ID Filing: SU7SAM1000

Navigation menu