SEBURY SAM-1000 Digital Keypad Introduction The SAM-1000 uses the latest microprocessor technology to operate door strikes and security systems that require a momentary (timed) or latching dry contact closure. All programming is done through the keypad. Codes and operating parameters are stored within the microprocessor and can not be lost due to power failure. The SAM-1000 can store 1000 prox cards and user 4 digit codes. Each 4 digit code has 10,000 possible combinations. The unit has one relay with 5 Amp contacts. CONTENTS Page Introduction ……………………………………………………………. 2 Product Specifications …………………………………………………. 3 Intramural Interface Circuit……………………………………………. Mounting & PCB Diagram ……………………………………………. 4 Wiring Diagram ………………………………………………………. 4-5 Engineer Programming Information and Notes …………………….. 5 Engineer Programming Factory Default Setting ………………………………………….. 6 Changing Master & User Codes………………………………….. 7 Setting Functions of Master & User ……………………………. 7 Set Door Relay Strike ……………………………………………… 7 Set Door Open Detection Time …………………………………. 8 Security Arrangement ……………………………………………. 9 Exit Engineer Programming Mode ……………………………… 9 Resetting Non Volatile Memory ………………………………………. 9 Installer Information & Notes …………………………………………… 9 Technical Specifications ….…………………………………………… 10 Specifications 1. Programmable Functions Relay latching or momentary Relay activate independently or together Change Codes 1 master, 1000 users & prox cards Door open detection 2. Programmable Timers Door relay time 00-99 seconds Door open detection 00-99 seconds Alarm time 00-99 minutes 3. Wiring Connections Electric lock External bell External Push Switch Magnetic Contacts Alarm 4. Keypad: 12 keys 5. Programming memory: Non volatile Eeprom memory IMPORTANT INFORAMTION There are no user serviceable parts contained within the SAM-1000 access control keypad. If holes are to be drilled before mounting onto a wall, check for hidden cables and/or pipes before drilling. Use safety goggles when drilling or hammering in cable clips. Every effort has been made to provide accurate information, however slight variations can occur. We also reserve the right to make changes for product improvement at any time NOTE PLEASE READ THESE INSTRUCTIONS CAREFULLY BEFORE ATTEMPTING TO INSTALL THE SAM-1000 Intramural Interface Circuit 1. Alarm output interface (See Figure 1) 2. Electric lock interface (See Figure 2) Figure 1 Figure 2 Mounting 1. Attach the rear plate to a single or double gang electrical box or secure to the wall firmly with at least three flat head screws. 2. When wiring has been completed, attach the front cover to the rear plate. Figure 3 Figure 4 The front cover can be permanently secured by using the short screw supplied SAM-1000 Printed Circuit Board Wiring 1. Unplug the cable harness and connect the necessary cables, (See Figure 5). 2. Tape any wires that are unused. 3. Plug the cable harness , (See Figure 5) 4. Attach the front cover, (See Figure 3). Terminal Wire Connector 1 Function 10 Bell1 Bell2 12V GND COM NO NC D_IN OPEN ALARM White White Red Black Orange Blue Green Brown Yellow Grey Bell Push Button Bell Push Button (+) 12Vdc Positive Regulated Power Input (-) Negative Regulated Power Input Door Strike Relay Com Door Strike Relay N/O Door Strike Relay N/C To Door Contact Then To Door In To Door Remote Control Button Then Negative Alarm Warning! Do not plug adaptor our transformer into mains until all wiring has been completed and the front cover secured. Figure 5 Power Up 1. After all wiring is complete and the unit face plate is attached to the back plate, apply 12Vdc power to the unit. Accept LED(the yellow LED) flashing. Engineer Programming Mode To enter programming mode Press: * 9999 # within 5 seconds, Ready(the green LED) and Accept LED illuminated, Open LED flashing. Note Press: # to save changes and exit engineer programming, when all programming has been completed otherwise changes will not be saved. Changing Master & User Codes In engineer programming mode: To change Master code Press: 0 new master code # re-enter new master code # Upon acceptance Open LED illuminates and stops flashing. Press after changing the master code, otherwise unit will disregard the new code and revert back to the factory default code. Note: the master code must be 4-8 digit number. Adding User Codes & Cards To Add User cards & codes Press: 1 read card user identification # Note: the user identification must be 3 digit number, if adding more than 1 card, read the next card after inputting the 3 digit code for the previous card, when you have finished adding all cards press the # key. 1st card must be 000 up to 999. Then the SAM-1000 control station added a user card it was auto added a user code with 1234. Delete User Card or Cards There are 3 options to delete a user card or cards, in engineering mode. a.) Press: b.) Press: c.) Press: 0 0 0 0 # to delete all user cards read card # to delete individual user card user identification number # to delete individual user card User Operation Mode There are 3 different options for user operation mode, card only, card and password, valid code. The optioned used is common to all users. Press: Press: Press: 00 01 02 valid card only valid card and password valid card or password Setting Door Relay Strike Time The door relay output can be operated as either normally opened or normally closed, a maximum current of 10 ampere can pass through the relay if used as normally opened or 5 ampere if normally closed. The door relay time can be set from 0 seconds to a maximum of 99 seconds. The factory default setting is 6 seconds and can be changed through the keypad. Press: new time from 00-99 seconds Setting Alarm Signal Output Time Press: new time from 00-99 minutes Setting Door Open Detection Press: Press: 6 00 6 01 to disable this function (factory setting) to enable this function. In order for this feature to work, door contacts must be connected. There are 2 programming functions that work together in this mode. a.) If door not closed after opening, keypad buzzer sounds. b.) If door forced open, keypad buzzer sounds and sends alarm signal. Setting Security Arrangement There are two levels of keypad security available for the SAM-1000. Press: 7 0 1 # to read 10 invalid cards or valid cards, then enter 4 wrong passwords in succession, the keypad is locked for 10 minutes. Press: 7 0 2 # to read 10 invalid cards or valid cards, then enter 4 wrong passwords in succession, the keypad activates and alarm signal. To disable this feature: Press: 7 0 0 # factory default setting. Resetting To Factory Default Setting To revert all settings to the factory default values then the Non Volatile Memory (Eeprom) must be reset. Reset Non Volatile Memory by switching of the power and placing the jumper connector onto the pins 1 & 2 as per figure 2. After switching power on remove jumper, the SAM-1000 will give a beep and is now reset to factory default values. Changing User Password Code The factory default setting for each user password code 1234, this can be modified so that each user has a unique individual 4 digit code. Press: * read user card new password # user passoword new password re-enter Using Password Code to release the door Press: user passoword # Technical Specification DC Supply Voltage: Current Consumption: Door Relay: Low voltage input 12 ±10% Vdc unregulated 100mA @ quiescent maximum 5Amp 12Vdc Alarm output load: Tamper Protection: Codes : Keypad: Card Types: Induction Distance: Wiring Connections: 150mA pull current Negative loop, normally closed 1 Master, 1000 cards and 1000 codes . 12 keys, 3 LED status indicators EM or EM compatible 5-8cm Electric lock Remote door control Door open detection External door bell External Alarm Memory: Operating Temperature: Keypad Housing: Dimensions: Weight: Non volatile eeprom memory 0°C to 60°C (32°F to 140°F) Metal 128mm x 82mm x 28mm 500g Package Listing Name Model no. Quantity Digital Keypad SAM-1000 User Manual SAM-1000 Flat Head Screws Pastern Stopper Self Tapping Screws Remark Φ3mm×6mm Used for front case and back case Φ6mm×27 mm Used for fixing Φ3.5mm×27 mm Used for fixing FCC WARNING This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. The antenna provided is a unique antenna. By installation of unauthorized antenna to this equipment. Such unauthorized installation could void the user's authority to opearte the equipment. NOTE: The manufacturer is not responsible for and radio or TV interference caused by unauthorized modifications to this equipment. Such modifications could void the user’s authority to operate the equipment. 10
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No XMP Toolkit : 3.1-701 Producer : Acrobat Distiller 7.0 (Windows) Creator Tool : PScript5.dll Version 5.2 Modify Date : 2008:02:22 13:58:56+08:00 Create Date : 2008:02:22 13:58:56+08:00 Format : application/pdf Title : Microsoft Word - User Manual.doc Creator : new Document ID : uuid:b93410b0-1ad9-4fc1-8c4a-b1579335f813 Instance ID : uuid:60d959c3-19f2-4930-8b45-e6e063fa90c8 Page Count : 10 Author : newEXIF Metadata provided by EXIF.tools