Cooper Lighting 2CL60WXSW Wireless Wall Switch User Manual 14 0074 Exhibit Cover

Cooper Lighting Wireless Wall Switch 14 0074 Exhibit Cover

Manual

5015 B.U. Bowman Drive Buford, GA 30518 USA Voice: 770-831-8048 Fax: 770-831-8598Certification ExhibitFCC ID: 2AC542CL60WXSWIC: 4706H-2CL60WXSWFCC Rule Part: 15.247IC Radio Standards Specification: RSS-247ACS Project Number: 14-0074Manufacturer: Cooper LightingModel: WOSW, WVSW
Installation Instructions INTERNAL ONLY GreengateWOSW & WVSWGeneral Information Read all instructions on both sides of this sheet first For indoor use only Install in accordance with ALL local codes Supports up to 64 paired wireless devices, 16K Groups Occupancy and Vacancy models available  Wireless solution for meeting basic ASHRAE 2010 and CA Title 24 occupancy detection Easy installation and setupAgency Listing and ComplianceMODEL: WOSW/WVSWFCC ID: 2AC542CL60WXSWIC: 4706H-2CL60WXSWThis device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesirable operation: Warning: Changes or modifications to this device not expressly approved by Eaton Lighting systems could void the user’s authority to operate the equipment.This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help.This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device.Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio exempts de licence. L’exploitation est autorisée aux deux conditions suivantes : (1) l’appareil ne doit pas produire de brouillage, et (2) l’utilisateur de l’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en compromettre le fonctionnement.
2Specificationswww.eaton.com/lightingsystemsRF Exposure: This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator and your body. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.Cet équipement est conforme aux limites FCC d’exposition aux radiations définies pour un incontrôlée environnement. Cet équipement doit être installé et utilisé à distance minimum de 20cm entre le radiateur et votre corps. Cet émetteur ne doit pas être co-localisées ou opérant en conjointement avec une autre antenne ou émetteur.SpecificationsModel WOSW/WVSWTechnology IEEE 802.11b/g/n WirelessFrequency Band2.4GHzNetworking and SecurityWPA-PSK and WPA2-PSKChannels 11 channelsWireless LAN Standard:802.11b/g/n at 2.4 GHzData Rates:802.11b: 1,2,5.5, 11 Mbps802.11g: 6, 9, 12, 18, 24, 36, 48, 54 Mbps802.11n: 7.2, 14.4, 21.7, 28.9, 43.3, 57.8, 65, 72 MbpsModulation:802.11b: CCK, DSSS802.11g: OFDM with BPSK, QPSK, 16-QAM, 64-QAM802.11n: OFDMInternet Protocol:IPv6Electrical Ratings120 VACIncandescent/ELV/MLV: 1680WLED/Electronic Ballast: 10AMLV: 1680VAMotor Load: ½ HP  277 VACLED/Electronic Ballast: 5AMLV: 1385VAMotor Load: ½ HPOperating EnvironmentTemperature: 32° to 104°F (0° to 40°C)Relative Humidity: 20% to 90%, non-condensingIndoor use only Housing Durable injection molded housing.  Resin com-plies with UL 94V-0Size Mounting Plate/Strap Dimensions:4.2”H x 1.8”W (106.5mm x 46mm)Product housing Dimensions: 2.87”H x 1.6”W x 1.42”D (72.8mm x 40.7mm x 36mm)LED Indicators Blue LED for operations status indication
3Product Descriptionwww.eaton.com/lightingsystemsProduct DescriptionThe Greengate Wireless Wall Switch Controller is a wireless control device that combines simple and secure user setup with robust communication offered by its industry leading 802.11 based architecture. The Wireless Wall Switch is used with companion WOAC-P Series Occupancy Sensors for energy savings and convenienceWiringCAUTION: Before installing or performing any service on a Greengate system, the power MUST be turned OFF at the branch circuit breaker.  According to NEC 240-83(d), if the branch circuit breaker is used as the main switch for a fluorescent lighting circuit, the circuit breaker should be marked “SWD”.  All installations should be in compliance with the National Electric Code and all state and local code.  NOTE REGARDING COMPACT FLUORESCENT LAMPS: The life of some compact fluorescent lamps (CFLs) is shortened by frequent automatic or manual switching. Check with CFL and ballast manufacturer to determine the effects of cycling.1.   Make sure power is turned OFF at the branch circuit breaker.2.  Wire units as shown in wiring diagrams per applicable voltage requirements.3.  Mount unit to Wall Box.4.  Turn power back ON at the branch circuit breaker and wait 30seconds for the unit to stabilize.5.  Make any necessary adjustments.6.  Install Wall Switch plate.
Eaton1000 Eaton BoulevardCleveland, OH 44122United StatesEaton.comEatonLighting systems203 Cooper CirclePeachtree City, GA 30269www.eaton.com/lightingsystems© 2015 EatonAll Rights ReservedPrinted in USAP/N: 9850-000450-00October 21, 2015Eaton is a registered trademark.All trademarks are property  of their respective owners. INTERNAL ONLYWARRANTIES AND LIMITATION OF LIABILITYPlease refer to www.eaton.com/lightingsystems under the Legal section for our terms and conditions.