Corbin Russwin 80 9380 8003 152 DC8210 X Unitrol

User Manual: Corbin Russwin DC8210 x Unitrol Wiring Diagrams and Instructions

Open the PDF directly: View PDF PDF.
Page Count: 5

Universal Door Closers with
Unitrol
IMPORTANT: An improperly installed or incorrectly adjusted door closer may cause
or and will void product warranty.
To avoid personal injury,
property
damage personal injury;
DO NOT DISASSEMBLE THIS DOOR CLOSER BODY.
Door closers must be securely fastened to a properly reinforced door and frame
with fasteners provided.
Door closers withaHOLD OPEN ARM (A12) are not permitted to be installed in fire
door assemblies.
Door and frame must be specifically templated for 85°, 90°, 95°, 100°, 105° or
110° door swing.
TO DETERMINE
HAND OF
YOUR DOOR:
LEFT
HAND
DOOR
RIGHT
HAND
DOOR
Size of Door&Door Closer
Type
of
Installation Interior Exterior
In -swinging
Exterior
Out -swinging
Recommended
Closer Size
**Max.
Opening
Force
lbs/f
2 4
2 6
3 0
3 6
4 0
4 6
' "
' "
' "
' "
' "
' "
2 6
3 0
3 6
4 0
' "
' "
' "
' "
8
14
16
22
24
26
1
2
3
4
5
6
**NOTE: These forces are for standard templating with bearing type hinges and do not account for pressure differentials and draft.
Parallel
Arm
RHR LHR
80-9380-8003-152 Rev. 07/09
DC8210 Series
Multi-Sized1thru 6
A11 - Non-Hold Open Arm
STANDARD APPLICATION
WITH 615F58 BRACKET
DEEP REVEAL APPLICATION WITH
M103 OPTION(615F59 CLAMP KIT)
FLUSH PARTITION APPLICATION WITH
M104 OPTION (615F60 BRACKET)
A12-Hold Open Arm
As Easy As
AC
BF
Installation Instructions
1
® Arms (by Norton)
80-9380-8003-152 Rev. 07/09
bmaJdnarooDkraM (for arm bracket).(for QUIK-INSTALL bracket)
®
Templates
85°
90°
95°
100°
105°
110°
90°
95°
100°
105°
110°
115°
5-3/4 (146)
5-1/4 (133)
4-3/4 (121)
4-3/8 (111)
4 (102)
3-3/4 (95)
HOLD
OPEN DEAD
STOP
9-3/4 (248)
9-1/4 (235)
8-3/4 (222)
8-3/8 (213)
8 (203)
7-3/4 (197)
9-7/8 (251)
9-3/8 (238)
8-7/8 (225)
8-1/2 (216)
8-1/8 (206)
7-7/8 (200)
8-1/8 (206)
7-5/8 (194)
7-1/8 (181)
6-5/8 (168)
6-1/4 (159)
6 (152)
11-7/8 (302)
11-3/8 (289)
10-7/8 (276)
10-3/8 (264)
10 (254)
9-3/4 (248)
12 (305)
11-1/2 (292)
11 (279)
10-1/2 (267)
10-1/8 (257)
9-7/8 (251)
10-1/4 (260)
9-3/4 (248)
9-1/8 (232)
8-1/2 (216)
8 (203)
7-5/8 (194)
14-1/4 (362)
13-3/4 (349)
13-1/8 (333)
12-1/2 (318)
12 (305)
11-5/8 (295)
14-3/8 (365)
13-7/8 (352)
13-1/4 (337)
12-5/8 (346)
12-1/8 (308)
11-3/4 (298)
Dim. A Dim. B *Dim. C
Opening
DOORS 28 TO 32" ” DOORS 33 TO 41" ” DOORS 42 TO 48" ”
Dim. A Dim. B *Dim. C Dim. A Dim. B *Dim. C
Frame Reveals 1-7/8 to 4-5/8
(48mm to 117mm)
" "
Reveal
Door
615F58
BRACKET
NOTES:
FRAME TEMPLATE 1A
(Standard Application with 615F58 Bracket)
Door Template is Typical for
all Frame Templates
, , and
615F52 NHO ARM (A11)
615F51 HO ARM (A12)
615F54 NHO ARM (A11)
615F53 HO ARM (A12)
615F56 NHO ARM (A11)
615F55 HO ARM (A12)
*Dimension “C” is only used for Flush Partition application (Frame Template ).
NOTE:
Dim A B
Dim A C
See chart to select degree of door opening and Door width for your door. Then,
determine frame condition: STANDARD & DEEP REVEAL (use ’s. & )
or FLUSH PARTITION (use ’s & ).
MINIMUM TOP RAIL for Standard Application: 5 (127)
MINIMUM TOP RAIL for Drop Plate Application: 2 (51)
3 Options of Frame Templates:
Standard Application, This Page ( )
Deep Reveal, Page
Flush Partition, Page 1/2
(13)
FRAME STOP
TOP OF DOOR
C
L
HINGE
OR
PIVOT
DOOR
FRAME STOP
2-3/4
(70) 3/8
(10)
2
(51)
7/16
(11)
B
TYP.
1-1/4
(32)
3/4
(19)
REVEAL 615F58
BRACKET
615F58
BRACKET
A
QUIK-INSTALL
BRACKET 754F18
10
(254)
1-1/8
(29)
3/8
(10)
3
(76)
4-3/4
(121)
3
(76)
3/8
(10)
11/16
(17)
3-1/4
(79)
1
(25)
DC8210 x A11 or A12 Parallel Arm Installation Instructions
A
A1
A2
A3
A1
2
2
3
3
A
C
B E
D
This&Next
Page
Following Pages(,,)
3 4 5
Check hand of door, see page .
Right Hand Application Shown
Left Hand Opposite
Dimensions given in inches (mm).
Do Not Scale Drawing.
Closer must be installed inatrue
horizontal plane to ensure proper
closer performance.
2
A2 A3A1
A3
DROP PLATE
Mounting Holes (4)
754F25
L
3/8
(10) 1/4-20 THREAD
Drill thru 9/32 (7) Enlarge to
3/8 (10) Dia. This Side Only
(4 Places)
MOUNTING SCREW SPECIFICATIONS
ARM AND BRACKETQUIK-INSTALL
}
or{Sex nuts, furnished
when ordered
#12-14 self-drilling screw.
1/8 (3) diameter pilot hole
required for Wood
DOOR
THICKNESS
SEX NUT
LENGTH “L”
1-3/8 (35)
1-3/4 (44)
& OVER
1-9/32 (33)
1-21/32 (42)
F
Applications.
1/2
(13)
C
L
HINGE
OR
PIVOT
DOOR
FRAME STOP
2-3/4
(70)
3/8
(10)
2
(51)
7/16
(11)
B
TYP.
REVEAL
5/16
(8)
2-1/8
(54)
4-3/8
(111)
615F59
CLAMP (TYP)
rooD
rooD
Clamps with Spacer
Clamps Only
SPACER
DEEP REVEAL APPLICATION with M103 OPTION (615F59 CLAMP KIT)FRAME TEMPLATE
FLUSH PARTITION APPLICATION with M104 OPTION (615F60 BRACKET)FRAME TEMPLATE
1-1/2
(38)
1/2
(13)
2-1/2
(64)
1-3/4
(44)
3/4
(19) CFrame Reveals 0 to 1/8 (0mm to 3mm)" "
Reveal
Frame Reveals Over 4-5/8 (117mm)
"
DoorFrame
Reveal
Reveal
CLAMP
FRAME
FRAME
CLAMP
615F60
BRACKET
80-9380-8003-152 Rev. 07/09
#12-24 x 5/8 FHMS (4)
C
Mount
Bracket
QUIK-INSTALL
B
DC8210 x A11 or A12 Parallel Arm Installation Instructions
3
A2
A3
A
C
B E
D
This P ageFollowing Pages
(,)
4 5
Mount Closer Body to
BracketQUIK-INSTALL
Start the four mounting screws into the four closer mounting holes.
Place the closer onto the bracket with the four
mounting screws inserted into the four bracket slots.
QUIK-INSTALL
QUIK-INSTALL
Tighten the four mounting screws to fasten the closer body to the
bracket.QUIK-INSTALL
#12-14X1-1/2 FH SELF-DRILLING (4)
OR
1/4-20 X 3/4 FHMS W/ SEX NUTS (4)
F
80-9380-8003-152 Rev. 07/09
Rotate
To Decrease
Hold Open
Force
To Increase
Hold Open
Force
Hold Open
“On” Hold Open Force
HOLD OPEN ADJUSTMENTS - A12 ARMS ONLY
Hold Open
“Off”
ALL ANGLES SHOWN ARE APPROXIMATE
Connect Arm To Closer
Using 1/8" hex wrench provided, close (turn clockwise)
CLOSING SPEED VALVE (see page for location on
closer). DO NOT OVER TIGHTEN.
Open door to approximately 60°
Using wrench on underside of spindle, rotate spindle
approximately 135° toward hinge edge of door.
Install arm on spindle at an approximate 90° angle to door.
Reopen CLOSING SPEED VALVE.
Install and tighten 5/16 Hex Head Arm Washer and Screw assembly.
DOOR
SPINDLE
ARM
CENTERLINE
DOOR
90°
SPINDLE
ROTATED 135°
Rotate 135°
SPINDLE AT REST
60°
DOOR
135°
WRENCH
90°
ARM
DC8210 x A11 or A12 Parallel Arm Installation Instructions
E
4
A
C
B E
D
This
Page
Next
Page ( )
5
Previous
Pages (,)
2 3
4
Mount Arm to Door Frame
D
#12-14 X 1-1/2 FH SELF-DRILLING (6)
F
80-9380-8003-152 Rev. 07/09
Interior Exterior
In
Swing
Exterior
Out
Swing
LATCHING
SPEED VALVE
BACKCHECK
INTENSITY VALVE
CLOSING
SPEED VALVE
SPRING POWER ADJUSTER
(1/4 ALLEN WRENCH)"
Size of Door
(Approx.)
Equivalent
Closer Size
DC8200 SPRING POWER ADJUSTMENT CHART
2 4 (712)
2 6 (764)
3 0 (915)
3 6 (1067)
' "
' "
' "
' "
3
4
5
6
2 6 (764)
3 0 (915)
' "
' "
2 6 (764)
3 0 (915)
3 6 (1067)
4 0 (1219)
' "
' "
' "
' "
Spring Power Adjustment
DC8200 Size1thru 6 Adjustment See Chart
All DC8200 closers are factory set at an approximate
Adjust closer as necessary for door size using this chart.
Readjustment may be required to suit prevailing conditions.
Size 3.
Locate spring power adjuster from Illustration below
Backcheck Intensity Valve
Turn valve COUNTER-CLOCKWISE to reduce backcheck
or CLOCKWISE to increase backcheck. (Backcheck should
be set to give a soft cushioning action, notasudden stop.)
Latching Speed Valve
After closing speed has been obtained, turn latching speed valve
CLOCKWISE to SLOW latching or COUNTER-CLOCKWISE to
SPEED latching for last 2 to 5 of door travel.
NOTE: Set combination of CLOSING and LATCHING speeds to
between3and 7 seconds Use of door by handicapped,
elderly or small children may require even greater
closing time.
" "
Closing Speed Valve
To adjust speed of door closing from fully open to a position
2 to 5 from closed, turn Closing Speed Valve CLOCKWISE
to SLOW closing, COUNTER-CLOCKWISE to SPEED
closing.
" "
Delayed Action Valve
Turn valve CLOCKWISE to SLOW closing, COUNTER-
CLOCKWISE to SPEED closing. Delayed action may be
adjusted from 20 seconds to 90 seconds, depending on
degree of door swing. Delay occurs at the beginning of the
door closing cycle from fully open down to 70°, where the
closing speed valve then begins its control.
Latch
C
l
o
s
i
n
g
S
p
e
e
d
B
a
c
k
c
h
e
c
k
D
e
l
a
y
e
d
A
c
t
i
o
n
Option
M71
Full Cover
(Standard)
(1/8 Allen Wrench Provided)
(1/8 Allen Wrench Provided)
(1/8 Allen Wrench Provided)
OPTION M71
DELAYED
ACTION VALVE
Insert is removable.
Place in unused opening.
2-7
7-11
11-15
15-17
Spring Power
Adjustment
No. Full Turns
Clockwise
DC8210 x A11 or A12 Parallel Arm Installation Instructions
A
C
B F
D
Previous P ages (,,)This
Page
2
Adjust Closer
F
5
3 4
E
Date Stamp
(on end of closer)
MM-YY
MM = Month
YY=Year
Slip cover over closer.
Hold tightly against QUIK-INSTALL® Bracket surface.
Secure on each side with 6-32 x 1/4 PBHMS screws."
Installing Cover
Copyright © 2007, 2009, Corbin Russwin, Inc., an ASSA ABLOY Group company. All
rights reserved. Reproduction in whole or in part without the express written permission
of Corbin Russwin, Inc. is prohibited.

Navigation menu