Corbin Russwin ED3200/ED3200A Series Rim Type Exit Device FM36205 15
ED3200/ED3200A Series Rim Type Exit Device CorbinFM362 Installation Instructions
User Manual: Corbin Russwin ED3200/ED3200A Series Rim Type Exit Device Wiring Diagrams and Instructions
Open the PDF directly: View PDF .
Page Count: 6
Download | |
Open PDF In Browser | View PDF |
® Installation Instructions ED3200/ED3200A Series Rim Exit Device In U.S.: Corbin Russwin, Inc. 225 Episcopal Road Berlin, CT 06037 USA www.corbinrusswin.com ASSA ABLOY In Canada: ASSA ABLOY Door Security Solutions Canada 160 Four Valley Drive Vaughan, Ontario, Canada L4K4T9 www.assaabloy.ca Technical Product Support: Phone: 888-607-5703 FM362 (05/15) To view helpful video installation tips, scan the Microsoft® Tags with your mobile phone. Download the free mobile app at http://getscanlife.com. Inactive Case Chassis Inactive Case Cover Tools Required 1. Measuring tape 2. Power drill 3. Drill bits: 3/32",1/4",11/32", 3/8", #25 4. Taps:#10-24 5. Screwdrivers: Phillips #2 and #3 Active Case Chassis Hex Dogging Key Plug Active Case Cover Locking Screw Crossbar Check Application For Proper Hand And Function. If Required, Adjust Exit Device As Follows: LHR Left Hand Reverse Hinges Left Open Outward FM362 (05/15) Locking Screw RHR Right Hand Reverse Hinges Right Open Outward Copyright © 2015 Corbin Russwin Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Corbin Russwin, Inc. is prohibited. 1 of 6 ® ED3200/ED3200A Series Rim Exit Device ASSA ABLOY To Change Hand Pivot A Unscrew Pivot and Remove Spring Support Assembly B Unscrew Pivot - Remove Latch Bolt and Reassemble It On Opposite Side C Reassemble Spring Support Assembly On Opposite Side (Make Sure Spring Rides On Latch Bolt Tail) RHRB SHOWN Identify Type of Installation Identify type of installation to determine location of vertical C L Single Door (Non-Fire Rated) Door For Standard strike Dim. “A” = 2-1/4" For S04 strike Dim. “A” = 1-3/4" Vertical reference line (CL of chassis) Double Door with 900 Mullion Door Double Doors With No Mullion Vertical Centerline of Active Case Door DOOR Standard Strike Vertical reference line (CL of chassis) 2-1/4" 2 of 6 Copyright © 2015 Corbin Russwin Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Corbin Russwin, Inc. is prohibited. Use Strike S02 FM362 (05/15) ® ED3200/ED3200A Series Rim Exit Device ASSA ABLOY A. Template Vertical CL of Inactive Case Horizontal CL of Inactive Case Holes TE MP T3 LAT 12 E 06 Tape Vertical CL of Active Case 38-5/8" Above Finished Floor TE M T3 PLA 12 TE 07 37-5/8" Above Finished Floor Lo ca te Inside Face of Door Te m pla tes Th is Di sta nc eA pa rt 1. Draw vertical centerline of active case based on types of installation. 2. Measure 37-5/8" above finished floor and draw horizontal line for active case template. 3. Align template (T31207) for active case with centerline and tape. 4. Using crossbar hole centers for measuring, draw vertical centerline of inactive case. FM362 (05/15) 5. Measure 38-5/8" above finished floor and draw horizontal line for inactive case template (1" higher than the active case). 6. Align template (T31206) for inactive case with centerline and tape. 7. Pin punch mounting holes for active and inactive cases on door. 8. Drill and tap holes in door, per the template (T31207). Copyright © 2015 Corbin Russwin Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Corbin Russwin, Inc. is prohibited. 3 of 6 ® ED3200/ED3200A Series Rim Exit Device ASSA ABLOY B. Active Case 1. Press in latchbolt and remove cover from active case chassis. 2. Mount chassis to door as indicated in Figures 1 and 2. 3. Depress the chassis arm to confirm the latchbolt retracts. Active Case Side (Away from Door Hinge) Hinge Side Figure 1 Active Case Mounting Screws - Actual Size Wood: #10 x 1-1/4" Phillips Flat Head (Total 4) Active Case Mounting Screws - Actual Size Metal: #10-24 x 3/4" Phillips Flat Under Cut (Total 4) Chassis Arm Figure 2 C. Inactive Case Inactive Case Side (Near Door Hinge) 1. Remove cover. 2. Mount chassis to door as indicated in Figures 3 and 4. Hinge Side Figure 3 Inactive Case Mounting Screws - Actual Size Wood: #10 x 1-1/4" Phillips Flat Head (Total 4) Inactive Case Mounting Screws - Actual Size Metal: #10-24 x 3/4" Phillips Flat Under Cut (Total 4) 4 of 6 Copyright © 2015 Corbin Russwin Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Corbin Russwin, Inc. is prohibited. Figure 4 FM362 (05/15) ® ED3200/ED3200A Series Rim Exit Device ASSA ABLOY D. Attach Outside Trim 1. Slide thrubolt screws thru inside chassis. 2. Thread cylinder into outside trim (if applicable). 3. Align outside trim with exposed thrubolt screws and secure. NOTE: For Nightlatch function, secure cylinder to chassis. This method allows cylinder to be removed at a later date for rekeying without taking device off door. Outside Trim Mounting Screws - Actual Size Cylinder Mounting Screws - Actual Size #10-24 x 2" Phillips Oval Head Machine Screw (Total 2) 1/4 -20 x 2-3/8" Phillips Flat Head (Total 2) E. Covers 1. Attach covers to both chassis and secure. Inactive Chassis Active Chassis Cover Mounting Screws - Actual Size #8-32 x 7/32" Phillips Oval Head (Total 8) FM362 (05/15) Copyright © 2015 Corbin Russwin Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Corbin Russwin, Inc. is prohibited. 5 of 6 ® ED3200/ED3200A Series Rim Exit Device ASSA ABLOY F. Crossbar 1. Slide crossbar into active chassis arm. 2. Slide crossbar into inactive chassis arm. Arm 3. Insert plugs and secure to bar with locking screws. 4. Depress the crossbar to confirm proper operation. Plug 5. Test for full latch retraction when dogged. Crossbar Mounting Screws - Actual Size Locking Screw Cross Bar #10-24 x 3/4" Socket Head Cap Screw (Total 2) G. Strike 1. Align strike onto door frame and adjust for proper position. 2. Center punch mounting holes. 3. Drill and tap holes in frame. 4. Secure strike in place. 5. Standing inside the room, close door and confirm latchbolt fully engages. Note: If latchbolt does not fully engage, review installation measurements of active and inactive chassis, and strike. 6 of 6 Copyright © 2015 Corbin Russwin Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Corbin Russwin, Inc. is prohibited. FM362 (05/15)
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : No Profile CMM Type : Lino Profile Version : 2.1.0 Profile Class : Display Device Profile Color Space Data : RGB Profile Connection Space : XYZ Profile Date Time : 1998:02:09 06:49:00 Profile File Signature : acsp Primary Platform : Microsoft Corporation CMM Flags : Not Embedded, Independent Device Manufacturer : IEC Device Model : sRGB Device Attributes : Reflective, Glossy, Positive, Color Rendering Intent : Perceptual Connection Space Illuminant : 0.9642 1 0.82491 Profile Creator : HP Profile ID : 0 Profile Copyright : Copyright (c) 1998 Hewlett-Packard Company Profile Description : sRGB IEC61966-2.1 Media White Point : 0.95045 1 1.08905 Media Black Point : 0 0 0 Red Matrix Column : 0.43607 0.22249 0.01392 Green Matrix Column : 0.38515 0.71687 0.09708 Blue Matrix Column : 0.14307 0.06061 0.7141 Device Mfg Desc : IEC http://www.iec.ch Device Model Desc : IEC 61966-2.1 Default RGB colour space - sRGB Viewing Cond Desc : Reference Viewing Condition in IEC61966-2.1 Viewing Cond Illuminant : 19.6445 20.3718 16.8089 Viewing Cond Surround : 3.92889 4.07439 3.36179 Viewing Cond Illuminant Type : D50 Luminance : 76.03647 80 87.12462 Measurement Observer : CIE 1931 Measurement Backing : 0 0 0 Measurement Geometry : Unknown Measurement Flare : 0.999% Measurement Illuminant : D65 Technology : Cathode Ray Tube Display Red Tone Reproduction Curve : (Binary data 2060 bytes, use -b option to extract) Green Tone Reproduction Curve : (Binary data 2060 bytes, use -b option to extract) Blue Tone Reproduction Curve : (Binary data 2060 bytes, use -b option to extract) Page Count : 6 Create Date : 2015:05:12 15:51:10-04:00 Modify Date : 2015:05:12 15:51:10-04:00 Producer : Corel PDF Engine Version 16.1.0.843 Author : Owner Creator : CorelDRAW X6 Title : Untitled-1EXIF Metadata provided by EXIF.tools