Corbin Russwin ED3200/ED3200A Series Rim Type Exit Device FM36205 15
ED3200/ED3200A Series Rim Type Exit Device CorbinFM362 Installation Instructions
User Manual: Corbin Russwin ED3200/ED3200A Series Rim Type Exit Device Wiring Diagrams and Instructions
Open the PDF directly: View PDF .
Page Count: 6
®
ASSA ABLOY
In U.S.:
Corbin Russwin, Inc.
225 Episcopal Road
Berlin, CT 06037 USA
www.corbinrusswin.com
In Canada:
ASSA ABLOY Door Security Solutions Canada
160 Four Valley Drive
Vaughan, Ontario, Canada L4K4T9
www.assaabloy.ca
Technical Product Support: Phone: 888-607-5703
Installation Instructions
1 of 6
Copyright © 2015 Corbin Russwin Inc., an ASSA ABLOY Group company.
All rights reserved. Reproduction in whole or in part without the express written
permission of Corbin Russwin, Inc. is prohibited.
ED3200/ED3200A Series
Rim Exit Device
FM362 (05/15)
FM362 (05/15)
Inactive Case
Cover
Hex Dogging Key
Active Case
Chassis
Active Case
Cover
Crossbar
Inactive Case
Chassis
Plug
Locking
Screw
Locking
Screw
LHR
Left Hand Reverse
Hinges Left
Open Outward
RHR
Right Hand Reverse
Hinges Right
Open Outward
Check Application For Proper Hand
And Function. If Required, Adjust Exit
Device As Follows:
Tools Required
1. Measuring tape
2. Power drill
3. Drill bits:
3/32",1/4",11/32", 3/8", #25
4. Taps:#10-24
5. Screwdrivers: Phillips #2 and #3
To view helpful video installation tips, scan the Microsoft® Tags with your
mobile phone. Download the free mobile app at http://getscanlife.com.
®
ASSA ABLOY
2 of 6 Copyright © 2015 Corbin Russwin Inc., an ASSA ABLOY Group company.
All rights reserved. Reproduction in whole or in part without the express written
permission of Corbin Russwin, Inc. is prohibited.
ED3200/ED3200A Series Rim Exit Device
To Change Hand
AUnscrew Pivot and
Remove Spring
Support Assembly
Pivot
BUnscrew Pivot - Remove Latch
Bolt and Reassemble It On
Opposite Side
CReassemble Spring Support
Assembly On Opposite Side
(Make Sure Spring Rides On
Latch Bolt Tail)
RHRB SHOWN
FM362 (05/15)
Identify type of installation to
determine location of vertical C
L
Single Door (Non-Fire Rated)
Door
Vertical reference line
(C of chassis)
L
For Standard strike Dim. “A” = 2-1/4"
For S04 strike Dim. “A” = 1-3/4"
Double Door with 900 Mullion
Door Door
Vertical reference
line (C of chassis)
L
Standard Strike
Double Doors With No Mullion
Vertical Centerline of Active Case
2-1/4"
DOOR
Use Strike S02
Identify Type of Installation
®
ASSA ABLOY
ED3200/ED3200A Series Rim Exit Device
A. Template
38-5/8" Above
Finished Floor
1. Draw vertical centerline of active case based on types of
installation.
2. Measure 37-5/8" above finished floor and draw horizontal
line for active case template.
3. Align template (T31207) for active case with centerline
and tape.
4. Using crossbar hole centers for measuring, draw vertical
centerline of inactive case.
5. Measure 38-5/8" above finished floor and draw horizontal
line for inactive case template (1" higher than the active
case).
6. Align template (T31206) for inactive case with centerline
and tape.
7. Pin punch mounting holes for active and inactive cases
on door.
8. Drill and tap holes in door, per the template (T31207).
Tape
Horizontal C
of Inactive Case
Holes
L
L
L
Inside Face
of Door
Vertical C of Inactive Case
TEMPLATE
TEMPLATE
Locate Templates This Distance Apart
37-5/8" Above
Finished Floor
Vertical C of Active Case
T31206
T31207
3 of 6
Copyright © 2015 Corbin Russwin Inc., an ASSA ABLOY Group company.
All rights reserved. Reproduction in whole or in part without the express written
permission of Corbin Russwin, Inc. is prohibited.
FM362 (05/15)
ED3200/ED3200A Series Rim Exit Device
C. Inactive Case
1. Remove cover.
2. Mount chassis to door as indicated in
Figures 3 and 4.
1. Press in latchbolt and remove cover from active
case chassis.
2. Mount chassis to door as indicated in Figures 1
and 2.
3. Depress the chassis arm to confirm the latchbolt
retracts.
B. Active Case
Chassis
Arm Figure 2
Hinge
Side
Active Case
Side
(Away from
Door Hinge)
Figure 1
Figure 4
Figure 3
Hinge
Side
Inactive Case
Side
(Near Door
Hinge)
4 of 6 Copyright © 2015 Corbin Russwin Inc., an ASSA ABLOY Group company.
All rights reserved. Reproduction in whole or in part without the express written
permission of Corbin Russwin, Inc. is prohibited.
Active Case Mounting Screws - Actual Size
Wood:
#10 x 1-1/4"
Phillips
Flat Head
(Total 4)
Metal:
#10-24 x 3/4"
Phillips Flat
Under Cut
(Total 4)
Active Case Mounting Screws - Actual Size
Inactive Case Mounting Screws - Actual Size
Metal:
#10-24 x 3/4"
Phillips Flat
Under Cut
(Total 4)
Inactive Case Mounting Screws - Actual Size
Wood:
#10 x 1-1/4"
Phillips
Flat Head
(Total 4)
FM362 (05/15)
®
ASSA ABLOY
ED3200/ED3200A Series Rim Exit Device
1. Slide thrubolt screws thru inside chassis.
2. Thread cylinder into outside trim (if applicable).
3. Align outside trim with exposed
thrubolt screws and secure.
D. Attach Outside Trim
NOTE:
For Nightlatch function, secure cylinder to chassis.
This method allows cylinder to be removed at a later
date for rekeying without taking device off door.
1/4 -20 x
2-3/8" Phillips
Flat Head
(Total 2)
Outside Trim Mounting Screws - Actual Size
#10-24 x 2"
Phillips Oval
Head Machine
Screw
(Total 2)
Cylinder Mounting Screws - Actual Size
5 of 6
Copyright © 2015 Corbin Russwin Inc., an ASSA ABLOY Group company.
All rights reserved. Reproduction in whole or in part without the express written
permission of Corbin Russwin, Inc. is prohibited.
FM362 (05/15)
1. Attach covers to both chassis and secure.
E. Covers
Inactive Chassis Active Chassis
#8-32 x 7/32"
Phillips Oval
Head
(Total 8)
Cover Mounting Screws - Actual Size
®
ASSA ABLOY
ED3200/ED3200A Series Rim Exit Device
1. Slide crossbar into active chassis arm.
2. Slide crossbar into inactive chassis arm.
3. Insert plugs and secure to bar with locking
screws.
4. Depress the crossbar to confirm proper
operation.
5. Test for full latch retraction when dogged. Cross Bar
Arm
Plug
Locking
Screw
Crossbar Mounting Screws - Actual Size
#10-24 x 3/4"
Socket Head
Cap Screw
(Total 2)
FM362 (05/15)
6 of 6 Copyright © 2015 Corbin Russwin Inc., an ASSA ABLOY Group company.
All rights reserved. Reproduction in whole or in part without the express written
permission of Corbin Russwin, Inc. is prohibited.
F. Crossbar
G. Strike
1. Align strike onto door frame and adjust for
proper position.
2. Center punch mounting holes.
3. Drill and tap holes in frame.
4. Secure strike in place.
5. Standing inside the room, close door and
confirm latchbolt fully engages.
Note: If latchbolt does not fully engage, review
installation measurements of active and inactive
chassis, and strike.
®
ASSA ABLOY