Installation Instructions
ED3600 & ED3600A Series
Mortise Exit Device

ASSA ABLOY

In U.S.:
Corbin Russwin, Inc.
225 Episcopal Road
Berlin, CT 06037 USA
www.corbinrusswin.com

In Canada:
ASSA ABLOY Door Security Solutions Canada
160 Four Valley Drive
Vaughan, Ontario, Canada L4K4T9
www.assaabloy.ca

Technical Product Support: Phone: 888-607-5703

FM363 (05/15)

To view helpful video installation tips, scan the Microsoft® Tags with your
mobile phone. Download the free mobile app at http://getscanlife.com.

Inactive Case
Chassis
Inactive Case
Cover
Tools Required
1. Measuring tape
2. Power drill
3. Drill bits:
3/32",1/4",11/32", 3/8", #25
4. Taps:#10-24
5. Screwdrivers: Phillips #2 and #3

Dogging Key

Active Case
Chassis

Active Case
Cover

Plug
Locking
Screw

Mortise
Lock

Crossbar
Check Application For Proper Hand
And Function. If Required, Adjust Exit
Device As Follows:

LHR
Left Hand Reverse
Hinges Left
Open Outward

FM363 (05/15)

Locking
Screw

Plug

RHR
Right Hand Reverse
Hinges Right
Open Outward
Copyright © 2015 Corbin Russwin Inc., an ASSA ABLOY Group company.
All rights reserved. Reproduction in whole or in part without the express written
permission of Corbin Russwin, Inc. is prohibited.

1 of 5

®

ED3600 & ED3600A Series Mortise Exit Device
ASSA ABLOY
A. Active Case Template
Vertical
CL of Inactive Case

Tape
Vertical CL of Active Case - "A"

TE

Horizontal CL
of Inactive Case
Holes

M
T3 PLA
12 TE
06

2-3/4"

38-5/8" Above
Finished Floor

TE

M
T3 PLA
12 TE
04

1. Measure 2-11/16" backset from center of door
edge and draw vertical centerline ("A").

43-1/8" Above
Finished Floor

2. Measure 43-1/8" above finished floor and draw
horizontal line for active case template.
3. Align template (T31204, LHR or T31205, RHR)
for active case with centerline and tape.

E
AT

PL

M
TE

Lo

Inside Face
of Door
ca

te

Te
m

4. Measure 38-5/8" above finished floor and draw
horizontal line for inactive case template.

pla

tes

Th

is

5. Using crossbar hole centers for measuring, draw
vertical centerline of inactive case.

Di

sta

nc

eA

pa

rt

6. Align template (T31206) for inactive case with
centerline and tape.

B. Mortise Lock

1. Slide lockbody into mortise pocket of door.
2. Fasten mortise lock in place.

Lock Mounting Screws - Actual Size

Lock Mounting Screws - Actual Size

Wood:
#12 x 1"
Phillips Flat
Head
(Total 2)

2 of 5

Copyright © 2015 Corbin Russwin Inc., an ASSA ABLOY Group company.
All rights reserved. Reproduction in whole or in part without the express written
permission of Corbin Russwin, Inc. is prohibited.

Metal:
#12-24 x 1/2"
Phillips Flat
Under Cut
(Total 2)

FM363 (05/15)

®

ED3600 & ED3600A Series Mortise Exit Device
ASSA ABLOY
C. Active Case

4. Lift active case chassis upward until the latchbolt is
completely retracted.

1. Remove cover from active case chassis.
2. Depress arm and tighten with dogging key (provided)
until held in down position (See 2a-2b).

5. With chassis in this position, mark hole locations for the
top of the chassis.

3. Position active case chassis against door so that the
center case lever rests underneath the bottom of the
mortise lockbody (See 3).

6. Remove chassis from door then drill and tap top holes.

Active Case
Chassis
Dogging Key

Active Case
Cover

2b

Latchbolt

1
3

NOTE: Center case lever must
engage with rear lever of
lockbody for latchbolt to retract.

Center
Case
Lever

2a

7. Undog arm by loosening with dogging key (provided), until arm rotates freely.
8. Align chassis with holes on door.
9. Screw in top two holes of active case chassis and mount to door.

Dogging Key

Active Case
Chassis

10. Mark bottom hole locations on active case chassis.
11. Remove chassis from door.
12. Drill and tap bottom holes.
13. Position chassis on door and screw in top and bottom holes.
14. Verify latchbolt arm retracts.

Active Case Mounting Screws - Actual Size
Wood:
#10 x 1-1/4"
Phillips
Flat Head
(Total 4)
FM363 (05/15)

Active Case Mounting Screws - Actual Size
Metal:
#10-24 x 3/4"
Phillips Flat
Under Cut
(Total 4)
Copyright © 2015 Corbin Russwin Inc., an ASSA ABLOY Group company.
All rights reserved. Reproduction in whole or in part without the express written
permission of Corbin Russwin, Inc. is prohibited.

3 of 5

®

ED3600 & ED3600A Series Mortise Exit Device
ASSA ABLOY
D. Inactive Case Template
Vertical
CL of Inactive Case
1. Center punch mounting holes for inactive case
on door.
2. Drill and tap holes in door.

Tape
TE

Horizontal CL
of Inactive Case
Holes

M
T3 PLA
12 TE
06

38-5/8" Above
Finished Floor
Inside Face
of Door

Lo

ca

te

Te
m

pla

tes

Th

is

Di

sta

nc

eA

pa

rt

E. Inactive Case
Inactive Chassis
1. Remove cover.
2. Mount chassis to door.

Active Case
Chassis

Inactive Case Mounting Screws - Actual Size
Wood:
#10 x 1-1/4"
Phillips
Flat Head
(Total 4)

Inactive Case Mounting Screws - Actual Size
Metal:
#10-24 x 3/4"
Phillips Flat
Under Cut
(Total 4)

4 of 5

Copyright © 2015 Corbin Russwin Inc., an ASSA ABLOY Group company.
All rights reserved. Reproduction in whole or in part without the express written
permission of Corbin Russwin, Inc. is prohibited.

FM363 (05/15)

®

ED3600 & ED3600A Series Mortise Exit Device
ASSA ABLOY
F. Attach Outside Trim

1. Slide thrubolt screws thru inside chassis and door.

Cylinder
Set
Screw

2. Install cylinder (if applicable).
3. Align outside trim with exposed thrubolt screws and
secure.

Cylinder

4. Tighten cylinder set screw (if applicable).

Outside Trim Mounting Screws - Actual Size
1/4 -20 x
2-3/8" Phillips
Flat Head
(Total 2)

G. Covers

1. Attach covers to both chassis and secure .

Inactive Chassis

Active Chassis

Cover Mounting Screws - Actual Size
#8-32 x 7/32"
Phillips Oval
Head
(Total 8)

H. Crossbar

1. Slide crossbar into active chassis arm.

Arm

2. Slide crossbar into inactive chassis arm.
3. Insert plugs and secure to bar with locking screws.

Plug

4. Depress the crossbar to confirm the latchbolt retracts.
Crossbar Mounting Screws - Actual Size

Locking
Screw

Cross Bar

#10-24 x 3/4"
Socket Head
Cap Screw
(Total 2)
FM363 (05/15)

Copyright © 2015 Corbin Russwin Inc., an ASSA ABLOY Group company.
All rights reserved. Reproduction in whole or in part without the express written
permission of Corbin Russwin, Inc. is prohibited.

5 of 5



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : No
Profile CMM Type                : Lino
Profile Version                 : 2.1.0
Profile Class                   : Display Device Profile
Color Space Data                : RGB
Profile Connection Space        : XYZ
Profile Date Time               : 1998:02:09 06:49:00
Profile File Signature          : acsp
Primary Platform                : Microsoft Corporation
CMM Flags                       : Not Embedded, Independent
Device Manufacturer             : IEC
Device Model                    : sRGB
Device Attributes               : Reflective, Glossy, Positive, Color
Rendering Intent                : Perceptual
Connection Space Illuminant     : 0.9642 1 0.82491
Profile Creator                 : HP
Profile ID                      : 0
Profile Copyright               : Copyright (c) 1998 Hewlett-Packard Company
Profile Description             : sRGB IEC61966-2.1
Media White Point               : 0.95045 1 1.08905
Media Black Point               : 0 0 0
Red Matrix Column               : 0.43607 0.22249 0.01392
Green Matrix Column             : 0.38515 0.71687 0.09708
Blue Matrix Column              : 0.14307 0.06061 0.7141
Device Mfg Desc                 : IEC http://www.iec.ch
Device Model Desc               : IEC 61966-2.1 Default RGB colour space - sRGB
Viewing Cond Desc               : Reference Viewing Condition in IEC61966-2.1
Viewing Cond Illuminant         : 19.6445 20.3718 16.8089
Viewing Cond Surround           : 3.92889 4.07439 3.36179
Viewing Cond Illuminant Type    : D50
Luminance                       : 76.03647 80 87.12462
Measurement Observer            : CIE 1931
Measurement Backing             : 0 0 0
Measurement Geometry            : Unknown
Measurement Flare               : 0.999%
Measurement Illuminant          : D65
Technology                      : Cathode Ray Tube Display
Red Tone Reproduction Curve     : (Binary data 2060 bytes, use -b option to extract)
Green Tone Reproduction Curve   : (Binary data 2060 bytes, use -b option to extract)
Blue Tone Reproduction Curve    : (Binary data 2060 bytes, use -b option to extract)
Page Count                      : 5
Create Date                     : 2015:05:12 14:55:06-04:00
Modify Date                     : 2015:05:12 14:55:06-04:00
Producer                        : Corel PDF Engine Version 16.1.0.843
Author                          : Owner
Creator                         : CorelDRAW X6
Title                           : Untitled-1
EXIF Metadata provided by EXIF.tools

Navigation menu