Corbin Russwin ED3600 & ED3600A Series Mortise Exit Device FM36305 15

ED3600 & ED3600A Series Mortise Exit Device FM363 Installation Instructions

User Manual: Corbin Russwin ED3600 & ED3600A Series Mortise Exit Device Wiring Diagrams and Instructions

Open the PDF directly: View PDF PDF.
Page Count: 5

®
ASSA ABLOY
In U.S.:
Corbin Russwin, Inc.
225 Episcopal Road
Berlin, CT 06037 USA
www.corbinrusswin.com
In Canada:
ASSA ABLOY Door Security Solutions Canada
160 Four Valley Drive
Vaughan, Ontario, Canada L4K4T9
www.assaabloy.ca
Technical Product Support: Phone: 888-607-5703
Installation Instructions
1 of 5
Copyright © 2015 Corbin Russwin Inc., an ASSA ABLOY Group company.
All rights reserved. Reproduction in whole or in part without the express written
permission of Corbin Russwin, Inc. is prohibited.
ED3600 & ED3600A Series
Mortise Exit Device
FM363 (05/15)
FM363 (05/15)
Inactive Case
Cover
Dogging Key
Active Case
Chassis
Active Case
Cover
Crossbar Mortise
Lock
Inactive Case
Chassis
Plug
Locking
Screw
Locking
Screw
LHR
Left Hand Reverse
Hinges Left
Open Outward
RHR
Right Hand Reverse
Hinges Right
Open Outward
Check Application For Proper Hand
And Function. If Required, Adjust Exit
Device As Follows: Plug
Tools Required
1. Measuring tape
2. Power drill
3. Drill bits:
3/32",1/4",11/32", 3/8", #25
4. Taps:#10-24
5. Screwdrivers: Phillips #2 and #3
To view helpful video installation tips, scan the Microsoft® Tags with your
mobile phone. Download the free mobile app at http://getscanlife.com.
®
ASSA ABLOY
ED3600 & ED3600A Series Mortise Exit Device
2 of 5 Copyright © 2015 Corbin Russwin Inc., an ASSA ABLOY Group company.
All rights reserved. Reproduction in whole or in part without the express written
permission of Corbin Russwin, Inc. is prohibited.
FM363 (05/15)
A. Active Case Template
1. Measure 2-11/16" backset from center of door
edge and draw vertical centerline ("A").
2. Measure 43-1/8" above finished floor and draw
horizontal line for active case template.
3. Align template (T31204, LHR or T31205, RHR)
for active case with centerline and tape.
4. Measure 38-5/8" above finished floor and draw
horizontal line for inactive case template.
5. Using crossbar hole centers for measuring, draw
vertical centerline of inactive case.
6. Align template (T31206) for inactive case with
centerline and tape.
Tape
Horizontal C
of Inactive Case
Holes
38-5/8" Above
Finished Floor
LVertical C of Active Case - "A"
L
L
2-3/4"
Inside Face
of Door
Vertical
C of Inactive Case
TEMPLA
TE
T31204
TEMPLA
TE
Locate T
emplates This Distance Apart
43-1/8" Above
Finished Floor
1. Slide lockbody into mortise pocket of door.
2. Fasten mortise lock in place.
B. Mortise Lock
TEMPLA
TE
T31206
Metal:
#12-24 x 1/2"
Phillips Flat
Under Cut
(Total 2)
Lock Mounting Screws - Actual Size
Lock Mounting Screws - Actual Size
Wood:
#12 x 1"
Phillips Flat
Head
(Total 2)
3 of 5
Copyright © 2015 Corbin Russwin Inc., an ASSA ABLOY Group company.
All rights reserved. Reproduction in whole or in part without the express written
permission of Corbin Russwin, Inc. is prohibited.
®
ASSA ABLOY
ED3600 & ED3600A Series Mortise Exit Device
1. Remove cover from active case chassis.
2. Depress arm and tighten with dogging key (provided)
until held in down position (See 2a-2b).
3. Position active case chassis against door so that the
center case lever rests underneath the bottom of the
mortise lockbody (See 3).
4. Lift active case chassis upward until the latchbolt is
completely retracted.
5. With chassis in this position, mark hole locations for the
top of the chassis.
6. Remove chassis from door then drill and tap top holes.
Dogging Key
Active Case
Chassis
Active Case
Cover 1
2a
2b
Center
Case
Lever
3
Latchbolt
NOTE: Center case lever must
engage with rear lever of
lockbody for latchbolt to retract.
C. Active Case
7. Undog arm by loosening with dogging key (provided), until arm rotates freely.
8. Align chassis with holes on door.
9. Screw in top two holes of active case chassis and mount to door.
10. Mark bottom hole locations on active case chassis.
11. Remove chassis from door.
12. Drill and tap bottom holes.
13. Position chassis on door and screw in top and bottom holes.
14. Verify latchbolt arm retracts.
Dogging Key
Active Case
Chassis
Metal:
#10-24 x 3/4"
Phillips Flat
Under Cut
(Total 4)
Active Case Mounting Screws - Actual Size
Active Case Mounting Screws - Actual Size
Wood:
#10 x 1-1/4"
Phillips
Flat Head
(Total 4)
FM363 (05/15)
®
ASSA ABLOY
ED3600 & ED3600A Series Mortise Exit Device
4 of 5 Copyright © 2015 Corbin Russwin Inc., an ASSA ABLOY Group company.
All rights reserved. Reproduction in whole or in part without the express written
permission of Corbin Russwin, Inc. is prohibited.
FM363 (05/15)
D. Inactive Case Template
1. Center punch mounting holes for inactive case
on door.
2. Drill and tap holes in door. Tape
Horizontal C
of Inactive Case
Holes
38-5/8" Above
Finished Floor
L
L
Inside Face
of Door
Vertical
C of Inactive Case
Locate Templates This Distance Apart
E. Inactive Case
1. Remove cover.
2. Mount chassis to door.
Inactive Chassis
TEMPLATE
T31206
Inactive Case Mounting Screws - Actual Size
Metal:
#10-24 x 3/4"
Phillips Flat
Under Cut
(Total 4)
Inactive Case Mounting Screws - Actual Size
Active Case
Chassis
Wood:
#10 x 1-1/4"
Phillips
Flat Head
(Total 4)
®
ASSA ABLOY
ED3600 & ED3600A Series Mortise Exit Device
H. Crossbar
1. Attach covers to both chassis and secure .
1. Slide crossbar into active chassis arm.
2. Slide crossbar into inactive chassis arm.
3. Insert plugs and secure to bar with locking screws.
4. Depress the crossbar to confirm the latchbolt retracts.
1. Slide thrubolt screws thru inside chassis and door.
2. Install cylinder (if applicable).
3. Align outside trim with exposed thrubolt screws and
secure.
4. Tighten cylinder set screw (if applicable).
G. Covers
Cylinder
Set
Screw
Cylinder
Cross Bar
Arm
Plug
Locking
Screw
Inactive Chassis Active Chassis
5 of 5
Copyright © 2015 Corbin Russwin Inc., an ASSA ABLOY Group company.
All rights reserved. Reproduction in whole or in part without the express written
permission of Corbin Russwin, Inc. is prohibited.
F. Attach Outside Trim
1/4 -20 x
2-3/8" Phillips
Flat Head
(Total 2)
Outside Trim Mounting Screws - Actual Size
Cover Mounting Screws - Actual Size
Crossbar Mounting Screws - Actual Size
#10-24 x 3/4"
Socket Head
Cap Screw
(Total 2)
#8-32 x 7/32"
Phillips Oval
Head
(Total 8)
FM363 (05/15)