INSTALLATION & SERVICE MANUAL
QUANTUM SERIES

IMI CORNELIUS INC.
www.cornelius.com

Part Number- 720901120
Revision B - November 23, 2004

TABLE OF CONTENTS
UNIT SPECIFICATIONS.................................................................... 1
PREINSTALLATION ...........................................................................2
Receiving ..............................................................................................................2
Unpacking ............................................................................................................. 2
Counter Location .................................................................................................. 2

installation specifications ............................................................... 3
Water Supply ........................................................................................................ 3
Electrical ................................................................................................................3
Space ................................................................................................................... 3
Connecting Water Supply .....................................................................................3
Filling Unit with Water ........................................................................................... 3
Flushing and Sanitizing on Start Up ..................................................................... 4
Programming Portion Control (optional) ...............................................................4
Cancel/Pour Button .............................................................................................. 4

Concentrate loading and brixing .................................................... 5
Placing Concentrate Products on Dispensing Platform........................................ 5
Changing Concentrate Flavor ............................................................................... 5
Pump Priming ....................................................................................................... 5
Brix Setting ........................................................................................................... 5

Cleaning and sanitizing procedures ............................................... 6
Daily: System Flush Procedure ............................................................................
Daily: Part Washing ..............................................................................................
Weekly: Sanitizing Procedure...............................................................................
Weekly: Check Brix Setting ..................................................................................
Semi-Annual: General Cleaning ...........................................................................
Yearly: Replace Pump Tubing..............................................................................

6
6
6
7
7
7

Trouble-shooting guide ................................................................. 11

Quantum Series Installation and Service Manual

UNIT SPECIFICATIONS
Clearance Recommended: 12” (30.48 cm) on top and 4” (10.16 cm) required in back for air circulation if sides are blocked off. If sides are open only 2” (5.08) are required in back. Space between
bottom of unit and counter cannot be obstructed in foot print area.
Electrical Connection: 6ft. long (1.83m) power cord with 3-prong plug attached to dispenser.
Export models have line cord less plug.
Power Supply: 15 amps at 120 volts or 10 amps at 220 volts.
Water Connection: 3/8” (0.95 cm) SAE male flare fitting on dispenser.
Water Supply Requirements: 80 psi (5.5 bar) maximum static pressure. 20 psi (1.4 bar) minimum
dynamic pressure; i.e., flowing pressure measured at dispenser water inlet with 3.0 ounces
(88.7ml) per second water flow.

-1-

720901120

Quantum Series Installation and Service Manual

PREINSTALLATION
RECEIVING
Each unit is completely tested and inspected before shipment. At time of shipment, the carrier
accepts the unit and any claim for damage must be made with the carrier.
Upon receiving from the carrier, please, inspect the carton for visible damage. If damage exists,
have the carrier make a note on the bill of lading and file a claim with the carrier.

UNPACKING
•
•
•
•
•
•
•

Remove staples securing carton to pallet.
Lift carton up and off of unit.
Remove top insert and shipping bag.
Open the upper cabinet door and remove installation kit.
Remove bolts securing unit to pallet.
Lift unit off of pallet.
Open the package, take legs and secure them to the bottom of the unit.
NOTE: Do not lay the unit on sides or on the back.

•
•

Tilt the unit only when securing legs.
If the unit is to be transported from the place where it was unpacked, do not remove the unit
from the pallet. Transport it on the pallet to the installation site.

COUNTER LOCATION
•

Select location in well ventilated area, close to grounded electrical outlet. If possible do not
place the unit close to hot and/or steaming machines.

720901120

-

2-

Quantum Series Installation and Service Manual

INSTALLATION
SPECIFICATIONS
W ATER SUPPLY
The Quantum Juice Dispensing machine is designed to dispense juice at a high flow rate. It is very
important that the incoming water line is dedicated for the unit, or at least does not have other
machines connected which could cause a water surge; i.e., a dishwashing machine.
NOTE: For increased cooling capacity the unit should be connected to a remote
recirculating cooling unit. If the location is equipped with a dedicated beverage water supply system the juice dispenser should be connected to it.
NOTE: The water supply should be consistent with proper water quality standard
(neutral ph of 7.0 to 8.0), and should not be connected to a water softener. The water cooling coil is Copper, and may be affected by poor water conditions (i.e. severe
corrosion and pitting).
Water connections shall be sized, installed, and maintained according to Federal, State, and Local
Laws.

ELECTRICAL
A minimum of 15 amps electrical service is needed for 120V power supply or 10 amps for 220V
supply.

SPACE
The minimum clearance is: 4” (10.16cm) in back and 12” (30.48cm) on top and open to the front if
sides are blocked off. If the sides are open then only 2” (5.08cm) is required in the back. Space
between the bottom of the unit and the counter cannot be obstructed.
NOTE: Condenser air is drawn from the bottom and discharged out the back. Failure to maintain clearance space will reduce capacity of the unit and cause premature compressor failure.

CONNECTING W ATER S UPPLY
1.

Secure 3/8” (0.95cm) flexible hose to the unit water inlet. Make sure that the seal washer is
used (hose and seal washer are included with the installation kit).

2.

When securing flare nut use backup wrench on male side of the fitting (unit side) to prevent
twisting of the copper tube inside the unit and/or possible damage to the water strainer/solenoid. A water shut off outside the unit is recommended.

FILLING U NIT

WITH

W ATER

To properly prime the unit with water, without air pockets in the system, push the dispensing
switches simultaneously for a few seconds each. Repeat above until a steady flow of water is
observed.
NOTE: Water splashing may occur during the purge cycle.

-3-

720901120

Quantum Series Installation and Service Manual

FLUSHING

AND

SANITIZING ON START UP

Follow standard sanitizing and flushing procedure.

PROGRAMMING PORTION CONTROL ( OPTIONAL)
The portion control supplied with your orange juice dispenser has been programmed to pour 7, 12,
and 16 ounce drinks. The “XL” size has also been programmed to pour 16 ounces. Should pour
size adjustments be required, please follow the instructions below:
1.

Simultaneously, press and hold “S” (small) and “XL” (extra large) push button switches on the
Portion Control Module until the led “REFILL” light in the corner of the module starts blinking.
Release the switches. The blinking led indicates the programming mode is active.

2.

Place the cup under the white mixing valve nozzle and push the selected size button (small,
medium, large, or extra large). Hold the button in until the cup fills to the desired portion, then
release the button repeat the above procedure for the remaining sizes.

3.

After programming all the drink sizes, press and release the “cancel/pour” switch to return the
Portion Control to the operational mode. The blinking led light will go out.
If at a future date, it is decided to change the portion size of the drinks, the individual sizes
can be adjusted by the above procedure. It is not necessary to reprogram every size.
The portion control has a full memory retention in case of a power failure.

CANCEL/POUR B UTTON
•
•

Push and release the cancel/pour button to stop the valve from dispensing.
Push and hold for a continuous pour.

720901120

-

4-

Quantum Series Installation and Service Manual

CONCENTRATE
LOADING AND BRIXING
PLACING C ONCENTRATE P RODUCTS

ON

D ISPENSING PLATFORM

To engage the concentrate container, place it in the desired position and press down into bottle
adapter opening on dispensing platform tray (inside the cabinet).
NOTE: Make sure o-ring seal on the container adapter is lubricated; otherwise, you
may experience difficulties with container replacement.
NOTE: Concentrate in the containers must be completely thawed and be within the
temperature range of 35°F - 40°F (1.6°C - 4.4°C). Failing to supply concentrate inside
the recommended temperature range, especially below 35°F (1.6°C), will cause an
out of brix drink.
It is recommended the concentrate be thawed in a refrigerated (35°F - 40°F) (1.6°C - 4.4°C) compartment for 36 to 48 hours before use.
It is recommended that the thawed concentrate be thoroughly shaken before use.

CHANGING CONCENTRATE F LAVOR
1.

Perform flush cycle

2.

Move valve handle to “Dispense” position

3.

Replace concentrate container

PUMP PRIMING
1.

Follow instructions in paragraph “Placing Concentrate Products on the Dispensing Platform”

2.

Close the door (or unit will not activate)

3.

Depress the push button until concentrate appears at the dispensing nozzle.

BRIX SETTING
1.

Make two (2) full clockwise turns of the corresponding brix knob from the “all the way out” position (factory set). These two turns will bring you within one turn of proper brix setting. (Refer
to brix table located on the inside of the refrigerated compartment door).

2.

Dispense 1/2 cup of juice and discard.

3.

Dispense 1/2 cup of juice and use refractometer to check brix level.

4.

Clockwise rotation of the knob decreases brix level for example from 13% to 11.5%. Counterclockwise will increase brix level for example from 11.5% to 13%.

If a brix problem is experienced, refer to troubleshooting guide.

-5-

720901120

Quantum Series Installation and Service Manual

CLEANING AND
SANITIZING
PROCEDURES
DAILY: S YSTEM F LUSH P ROCEDURE
1.

A 1 quart (0.95 liters) (32 fluid oz. minimum) empty container is needed. Place the empty container on the drip tray grill under the nozzle of the dispensing station to be flushed.

2.

Open the cabinet door.

3.

Choose the valve handle that corresponds with dispensing station to be flushed.

4.

Move chosen handle from “dispense” position to the “flush” position.

5.

Close the door.

6.

Depress and hold push button corresponding with dispensing station to be flushed, until clear
water is dispensed from the nozzle.

7.

Move the handle to the “dispense” position.

8.

Depress the push button for approximately 0.5 sec. and release. This will release water pressure from the pump system.
It is recommended to use one or more quarts of water to flush a single dispensing station.

DAILY: P ART W ASHING
1.

Remove and wash dispensing nozzle, static mixer, splash plate, drip pan, bracket, and grille
in a mild detergent solution. Rinse thoroughly.

W EEKLY: S ANITIZING P ROCEDURE
1.

Remove juice concentrate container from unit and place in separate refrigerated compartment.

2.

Perform flush procedure.

3.

Fill a clean empty concentrate container with one quart of extremely hot tap water, approximately 140°F (60°C) and place into unit. Run the hot water completely through unit into a large
container. When complete remove concentrate container.

4.

Remove nozzles and static mixers from unit and rinse under hot tap water to remove excess
pulp.

5.

Place nozzles and static mixers in separate container with 1 quart (0.95 liter) of sanitizing solution and agitate vigorously, using brush (P/N 07932) to remove any excess pulp or concentrate (allow to soak for 2 minutes).

6.

Clean bottle adaptor’s inlet area along with dispensing platform tray with brush and sanitizing
solution to remove concentrate and pulp.

7.

Clean valve mixing chambers with brush and sanitizing solution. (This is the cavity from which
the nozzle is removed).

8.

Replace nozzles and static mixers into proper location.

720901120

-

6-

Quantum Series Installation and Service Manual

9.

Fill a clean empty concentrate container with 2 quarts (1.9 liters) of sanitizing solution, place
on dispensing platform, and insert bottle fitting into bottle adapter.
NOTE: Do not reuse the same sanitizing solution used to clean nozzles, static mixers, etc.

10. Place handle in dispense position and close door.
11. Run dispensing station for 90 seconds then stop; allow sanitizing solution to remain in lines
for 5 minutes.
12. Dispense remaining sanitizing solution (approximately 90 seconds).
13. Replace sanitizing solution container with a concentrate container, and close door.
14. Depress and hold push buttons until juice appears at outlet of dispensing nozzle.
15. Dispense and discard two 8 oz. cups (236.6 ML) of juice.
NOTE: Wipe internal and external surfaces of cabinet with a clean damp cloth.

W EEKLY: C HECK BRIX SETTING
Tools: Hydrometer or Refractometer
1.

Dispense required ounces of juice per brix testing device instructions.

2.

Test concentrate to water ratio of dispensed juice per brix testing device instructions.

3.

Clockwise rotation of knob decreases brix level (i.e. from 13% to 11.5%). Counterclockwise
rotation of knob increases brix level (i.e. from 11.5% to 13%).
NOTE: If brix problem persists, refer to trouble shooting guide.

SEMI-A NNUAL: G ENERAL C LEANING
1.

Remove access port of Y-shaped water solenoid located on water inlet in lower cabinet, clean
stainless steel strainer and reinstall.

2.

Clean condenser fins.

3.

Clean air inlet grille located in base of unit.

4.

Clean lower cabinet interior.

5.

Wipe fan blade clean.

YEARLY: R EPLACE P UMP T UBING
Removal of Platform (see figure 1):
1.

Remove concentrate container from the dispenser and place in a refrigerator.

2.

Remove the product shelf.

3.

Depress the button on the water line quick disconnect and lift the water line away from the
platform.

4.

Unplug the platform electrical connector at the inside rear of the cabinet.

5.

Release the catch at the front of the platform by pulling the tab towards yourself with on finger.

-7-

720901120

Quantum Series Installation and Service Manual

6.

Remove the nozzle and static mixers.

7.

Carefully lift and pull the platform from the dispenser and place it in a clean and well lit area
for service.

Replacement of Pump Hose (see figure 2):
1.

Remove platform as described above in removal of platform instructions.

2.

Remove the two white plastic hose clamps from the pump tube connections. Remove the two
stainless steel concentrate delivery tubes from the hose ends.

3.

Loosen and remove the four thumb screws from the pump body.

4.

Remove the rear half (only) of the pump body to reveal the hose and rollers.

5.

Remove the old hose from the pump body. If the rollers come out with the hose, place in back
into the housing being sure to align the roller assembly shaft keyway to the motor shaft key
so that the two interlock (see figure 3 for step by step pictorial instructions).

6.

Firmly press the new hose into the pump body around the roller assembly, being sure to keep
the protruding ends even with each other. Once the hose is in place, replace the outer half of
the pump body. Hold the tubing in place inside pump housing with one hand, capture the lower
part of the tubing with the outer housing, then proceed to capture the shaft of the roller assembly and push the housing straight onto the pump/motor portion of the assembly. Make sure to
capture the hose within the body and not pinch it between the halves. Do not use any tool
other than your finger tips to manipulate the hose into the housing or damage to the hose will
result.

7.

While holding the pump halves together by hand, reinsert the four thumb screws and tighten
them in a criss-cross pattern until the two halves are pressed together.

8.

Insert the two stainless tubes into the hose ends and fasten them with new clamps using pliers
to tighten the clamps.

Replace platform in unit, reinstall nozzles and static mixers, connect water, install product
shelf and concentrate, and reconnect power to unit.

720901120

-

8-

Quantum Series Installation and Service Manual

-9-

720901120

Quantum Series Installation and Service Manual

720901120

-

10 -

Quantum Series Installation and Service Manual

TROUBLE-SHOOTING
GUIDE
The following pages contain trouble-shooting charts designed to aid an experienced serviceman in
diagnosing any operating problems that may be experienced. In order to gain maximum benefit
from the charts, please note:
1.

Start at the beginning of the chart and supply the appropriate answer to each question.

2.

Do not skip any section, unless instructed to do so. You may miss the solution to your problem.

3.

Evaluate the possible problem causes in the sequence in which they are presented. In general, they began with the most likely and/or easiest to check, and proceed to the less likely
and/or more complicated.

4.

If, after checking all indicated causes, the problem is not resolved, it is recommended that you
try a second time. Evaluate symptoms carefully and modify your answers as necessary.

5.

If you are unable to resolve a problem after several attempts, contact customer service department at (1-800-238-3600) for assistance.
PROBLEM
Totally Inoperative

No cooling

PROBABLE CAUSE

REMEDY

No power to dispenser due
to tripped circuit
breaker.

Reset circuit breaker. Confirm that
breaker is correct size and no
other equipment is operating on
the same circuit. Also confirm
that supply voltage is +10% of
nameplate specifications.

Loose or broken power supply connection inside
dispenser.

Repair connection

Line voltage is not within
+10% of nameplate
specifications causing
compressor overload to
trip

Contact an electrician

Both thermostats in OFF
position

Turn ON thermostats and recalibrate the temperatures to 34 o F
-40 o F (1.1 o C –4.5 o C).

Defective compressor overload or start capacitor

- 11 -

Replace

720901120

Quantum Series Installation and Service Manual

No cooling (con’t)

No water dispensed,
concentrate only.

720901120

Defective start relay located
on upper rear shelf
inside dispenser

There should be line voltage on the
black wire of the relay when
there is line voltage present on
the orange OR yellow wire.
Replace relay if it fails this test.

Compressor starts but
hums and trips overload

Seized or shorted compressor,
replace.

Compressor starts but does
not switch off of start
winding

Relay or compressor is defective.
Test and replace faulty item.

Compressor short cycles on
overload

Excessively high discharge pressure due to restricted condenser or inoperative
condenser fan motor

Refrigerant leak

Repair leak. Evacuate and
recharge system.

No water to dispenser

Restore water

Water supply line inside
refrigerated cabinet disconnected from pump
platform

Reconnect

Water solenoid located on
pump platform clogged
or defective

Disassemble and clean solenoid.
Replace if necessary.

Main water solenoid/
strainer located at base
of dispenser is clogged,
binding or defective

Remove and clean strainer. Confirm 28VDC is present at solenoid during dispense. Confirm
solenoid coil is not open. Disassemble and clean solenoid.

Water supply pressure is
greater than 80 psi (5.5
bar)

Add external regulator and lower
pressure to 50 psi (3.5 bar)

-

12 -

Quantum Series Installation and Service Manual

No water dispensed,
concentrate only
(con’t).

Freeze-up of water coil or
concentrate chamber

Unplug dispenser and allow 2-4
hours to thaw. Water or concentrate thermostat set too low,
recalibrate to 34oF -40 oF (1.1
oC

- 4.5 o C).

Defective water or concentrate
thermostat, replace.
Refrigerant solenoid stuck open
or not closing fully. Evacuate
system, replace solenoid valve
and recharge
No water and no concentrate, refrigeration is
working

No water and no concentrate, refrigeration is
working

Service switch located
under drip tray in OFF
position

Turn on switch

Door switch open

Door switch must be closed in
order to operate pump. Check
switch operation and replace if
necessary

6.25 amp Fuse inside front
electrical box blown

Replace with 6.25 amp, 250VAC
slow blow fuse and test

No output from Transformer
located on rear upper
shelf

Confirm transformer output by
measuring for 26VAC at fuse.
Replace transformer if necessary

Defective voltage regulator
board (VRB) located
inside front electrical
box

Measure across the blue and black
wire located in the upper left
corner of the board. There
should be 28VDC present when
the dispense button is pressed.
Replace VRB if necessary

Defective portion control
board

Disconnect wire harness from rear
of portion control, close door
switch and short the orange
and black wires together on the
harness. If unit dispenses portion control board is defective. If
it does not dispense the voltage
regulator board is defective.

- 13 -

720901120

Quantum Series Installation and Service Manual

No concentrate dispensed, water only

Excessive remnant left
in empty concentrate pouch

Concentrate refill light
comes on prematurely

Concentrate refill light
does not come on at
all

720901120

Dispense tube not fully
engaged into receptacle on concentrate
pouch

Refer to Concentrate Loading section of this manual

Dispense tube disconnected from mixing
chamber

Refer to Concentrate Loading section of this manual

Slide block on pump in
open position

Close and lock the slide block.
Refer to Concentrate Loading
section of this manual

Switch on pump platform in
FLUSH position

Move switch to RUN position

Concentrate too cold, not
properly thawed

Concentrate should be 34o F -40 o F

Defective pump motor

Replace pump motor

Concentrate pouch improperly thawed

Concentrate should be 34o F -40 o F

Concentrate pouch and/or
dispense tube improperly installed

Refer to Concentrate Loading section of this manual

Concentrate pouch improperly thawed

Concentrate should be 34o F -40 o F

Concentrate pouch and/or
dispense tube improperly installed

Refer to concentrate loading section of this manual

Loose wiring

Check wiring connections between
the pump motor and the VRB
board

Bad VRB board

Replace VRB board

Bad pump motor

Replace pump motor

Pump improperly locked or
pump is open

Close and lock Pump

Run/flush switch is in the
FLUSH position

Move switch to the RUN position

-

14 -

(1.1 o C –4.5 o C) prior to loading

(1.1 o C –4.5 o C) prior to loading

(1.1 o C –4.5 o C) prior to loading.

Quantum Series Installation and Service Manual

Concentrate refill light
does not come on at
all (con’t)

Improperly loaded tube

Refer to concentrate loading section of this manual

Bad VRB board

Replace VRB board

Bad portion control

Replace portion control

Incoming water supply too
warm

Optimum performance is achieved
when the dispenser utilizes
water from a pre-cooler

Ambient air too warm

Relocate dispenser

Excessive demand on dispenser

Add water pre-cooler or second
dispenser

Dirty condenser coil

Clean condenser coil

Inoperative condenser fan

Replace condenser fan motor

Defective water thermostat

Replace thermostat

Loss of refrigerant charge
due to leak in system

Repair leak and recharge system

Water continuously drips
from nozzle when in
OFF mode

Main water solenoid at base
of unit or water solenoid
on pump platform not
shutting off tightly

Clean solenoid(s), replace parts as
necessary

No Flush Cycle

Run/Flush switch on pump
platform in Run mode

Move switch to Flush position

Defective Run/Flush switch
on pump platform (concentrate continues to
dispense while in Flush
mode)

Replace Run/Flush switch

Concentrate thermostat is
turned off or not calibrated properly

Calibrate to be 34o F -40 o F (1.1 o C

Concentrate thermostat
defective (stuck open)

Replace thermostat and calibrate

Defective start relay located
on upper rear shelf
inside dispenser

There should be line voltage on the
black wire of the relay when
there is line voltage present on
the orange OR yellow wire.
Replace relay if it fails this test.

Warm Drink

Concentrate warm,
water cold

- 15 -

–4.5 o C)

to 34 o F -40 o F (1.1 o C –4.5 oC)

720901120

Quantum Series Installation and Service Manual

Concentrate warm,
water cold (con’t)

Loss of refrigerant charge
due to leak in system

Repair leak and recharge system

Brix Problem

Water supply pressure too
low, less than 20 psi (1.4
bar) flowing or water
pressure fluctuates
sharply

Correct water supply problem to
ensure a constant 40 psi (3 bar)
flowing to the dispenser

Water flow control binding
or spring is defective

Clean and/or replace parts as necessary

Improperly thawed concentrate. Brix changes as
the concentrate temperature changes (concentrate becomes thinner
as temperature rises)

Concentrate should 34 o F -40 o F

Check that the rollers on the
pump are spinning
freely with no tube in
place

If they are sticky or locked up see
platform removal and cleaning
procedure.

Pump motor defective

28VDC should be present at pump
motor during dispense. If voltage is present and motor does
not start, replace pump motor

No power to transformer or
no 28VAC output from
transformer

Confirm transformer has line voltage present on primary side. If
no 28VAC output from the secondary replace transformer

Defective voltage regulator
board (VRB) located
inside front electrical
box

Measure across the blue and black
wire located in the upper left
corner of the board. There
should be 28VDC present when
the dispense button is pressed.
Replace VRB if necessary

Defective portion control
board

Disconnect wire harness from rear
of portion control, close door
switch and short the orange
and black wires together on the
harness. If unit dispenses portion control board is defective. If
it does not dispense the voltage
regulator board is defective.

Pump Inoperative

720901120

-

16 -

(1.1 o C –4.5 o C) prior to loading

Quantum Series Installation and Service Manual

Machine continues to
dispense after dispense button is
released or dispenses without
operator input

Sold Out light illuminates when concentrate no longer
passes through the
pump.

Portion control pad stuck in
on position

Disconnect the wire harness from
the rear of the portion control
and close the door. If unit does
not dispense on its own the portion control is bad (stuck on)

Relay on voltage regulator
board (VRB) stuck on.

Disconnect the 4-wire harness
from the lower right corner of
the VRB. If the unit continues to
dispense on its own the VRB is
defective (relay stuck on)

The concentrate is improperly thawed. The temperature is not
maintained between
34×F - 40×F(1.1-4.5×C)

Assure proper thawing procedures
have been followed per the
Minute Maid company instructions.
Check that McDonald’s walk-in
cooler temperature is on the
proper set point.
Check the dispenser cabinet temperature is at 34×F - 40×F(1.14.5×C).

High Brix readings result in
a poor, pulsating/splashing dispense, erratic
pump amp draw, and
consequently erratic
sold-out indications.

- 17 -

Check drink brix in procedure
described on equipment P.M.
card using the hydrometer provided.
Check the drink flow rate under
normal operating conditions.
The dispenser should pour a
drink at a flow rate of approximately 1.5 oz. Per second or
greater. If the flow rate is less, a
check described in the Sold Out
section should be completed.

720901120

Quantum Series Installation and Service Manual

Sold Out light illuminates when concentrate no longer
passes through the
pump.(con’t)

Improper loading procedures will usually result
in low brix conditions
and thus erratic sold out
indications.

Check that the pouch of juice is
properly loaded in the pouch
holder. Tube fitting should be
located at the bottom of the
pouch holder and the tube
should be approximately centered in the bottom portion of
the opening of the holder.
Check that the tube is correctly
loaded in the pump and the
pump is fully locked (top and
bottom slide pins should be
fully engaged into the pump
body).

Sold Out light fails to
reset itself after door
is opened and
closed (Sold Out
light stays illuminated)

720901120

Tube has been stretched
through pump when it
was loaded. Pouch may
not be seated correctly.

Adjust pouch. If pouch is loaded
correctly there should be ample
tube to reach the mixing chambers without stretching the
tube.

Check that the rollers on the
pump are spinning
freely with no tube in
place.

If the rollers are sticky or locked up
see the platform removal and
cleaning procedure.

Check the operation of the
reset switch located at
the bottom left hand
side of the door.

Adjust Switch.

-

18 -

IMI Cornelius Inc.
One Cornelius Place
Anoka, MN 55303-1592
U.S.A.

Total Systems Commitment

IMI CORNELIUS INC.
One Cornelius Place
Anoka, MN. 55303–6234
Telephone 1-800-238-3600
Facsimile 1-800-258-0255
www.cornelius.com

ILLUSTRATED PARTS LIST

QUANTUM SERIES JUICE DISPENSER

MODEL NO.
45200001
45200002
45200003
45200004
45200101
45200102
45200103
45200104
45400001
45400002
45400101
45400102
45400103
45400104
45500001
45500002
45500101
45500102
45650001
45650003
45650101
45650103
45650104
45650105

QUANTUM SERIES

1 of 16
Rev A

Manual Part No. 720901120IPL
4-25-2001 Rev: 12-3-01
IMI Cornelius Co., 2001

IMI CORNELIUS INC.
One Cornelius Place
Anoka, MN. 55303–6234
Telephone 1-800-238-3600
Facsimile 1-800-258-0255
www.cornelius.com

ILLUSTRATED PARTS LIST

QUANTUM SERIES JUICE DISPENSER

3
29

36
2

20

41

13

31

17
11

27

42

39

28

12

22

4
36
30

35
16

14

21

34
32

36

9
39
25
41
41
2
6

2

3
3
38
36
23

37
15
1
40

10
8

7
36

19

33
36

24

26
36

36

5
35

18

36

FIGURE 1. GENERAL ASSEMBLY

Manual Part No. 720901120IPL
4-25-2001 Rev: 12-3-01
IMI Cornelius Co., 2001

2 of 16
Rev A

QUANTUM SERIES

IMI CORNELIUS INC.
One Cornelius Place
Anoka, MN. 55303–6234
Telephone 1-800-238-3600
Facsimile 1-800-258-0255
www.cornelius.com

ILLUSTRATED PARTS LIST

QUANTUM SERIES JUICE DISPENSER
Item
No.
1
2
3

Part No.
0720405
0730202
0706903
07061002

4
5

07344
45366

6
7

0733904
45107

8

9

10
11

12

7245669
45408
45159001
45667100
45459100
45003
31525037
45123
48808001
470725
45354
45241
45390
45470
7245550
45296006
45394005
45481006

13

14
15
16
17

309852000
77060900
49034
45439

45115
45215
45215001
45315

18

45129001
45129100
45678100
45430100

QUANTUM SERIES

Item
No.

Name
Nut 1/4-20
Washer No. 10 Split Lock
Screw No. 10-32 x 1/2” TH SS
115V 60HZ
Screw No. 10 x 5/8” HHWF
230V 50HZ
Bushing Snap 3000 and 4000 Series
Brkt and Tube Drain
3000 and 4000 Series
Bushing Snap
Cover Elec Box 1000 and 2000
Series
Cover Elec Box 3000 Series
Cover Elec Box 4000 Series
Panel Splash 1000 and 2000 Series
Panel Splash 3000 Series
Panel Splash 4000 Series
Nozzle Mixer O-Ring Asy
O-Ring .739 I.D.
Mixer Static
Nozzle Mixing
Plug Butn
DoorAsy 1000 Series(SeeFigure8)
DoorAsy 2000 Series(SeeFigure8)
DoorAsy 3000 Series(SeeFigure8)
DoorAsy 4000 Series(SeeFigure8)
Cover Asy 1000 Series
(See Figure 10)
Cover Asy 2000 Series
(See Figure 10)
Cover Asy 3000 Series
(See Figure 10)
Cover Asy 4000 Series
(See Figure 10)
Clamp 1000, 2000 and 3000 Series
Fitg T-Brb 3/8 1000, 2000 and 3000
Series
Tube 1000, 2000 and 3000 Series
Washer Nylon
Refrigeration Asy (See Figure 2)
Cabinet Asy (See Figure 3)
Platform Asy 1000 Series (See
Figure 4)
Platform Asy 115V 60HZ, 2000 and
4000 Series (See Figure 4)
Platform Asy 230V 50HZ, 2000 and
4000 Series (See Figure 4)
Platform Asy 115V 60HZ, 3000
Series (See Figure 4)
Drip Tray, 1000 Series
Drip Tray, 2000 Series
Drip Tray, 3000 Series
Drip Tray, 4000 Series

3 of 16
Rev A

19

20

21
22
23

24

Part No.
45155001
45255003
45677003
45455003
45158
45117
45317
45417
45444
45151
45666
45451
46546
45152

25

96561
45436

26
27
28
29
30
31
32

7245443
49154
45165100
49155
309852000
49157
45199
45659
45445
45125
7245665
45425
7245765
7245763
7245764
07115001
0704106
45088
45087
0702901
45164
45032
45464
0730104
0720406

33

34

35
36
37
38
39
40

41
42
43

Name
Cup Rest, 1000 Series
Cup Rest, 2000 Series
Cup Rest, 3000 Series
Cup Rest, 4000 Series
Shelf, 1000 Series
Shelf, 2000 Series
Shelf, 3000 Series
Shelf, 4000 Series
Strap
Electrical Box Asy (See Figure 12)
Brkt Water Coil 1000 and 2000
Series
Brkt Water Coil 3000 Series
Brkt Water Coil 4000 Series
Arm Asy
Brkt Asy Drip Tray 1000 Series
(Not Shown)
Plate Door Support 1000 Series
Plate Door Support 2000, 3000 and
4000 Series
Panel RH Side
Plate Hinge Upper
Coil Wtr Asy
Hinge Bolt Shoulder
Clamp
Bushing Upper Hinge
Panel Top 1000 and 2000 Series
Panel Top 3000 Series
Panel Top 4000 Series
Panel Back 1000 and 2000 Series
Panel Back 3000 Series
Panel Back 4000 Series
Brkt Cabinet 1000 and 2000 Series
Brkt Cabinet 3000 Series
Brkt Cabinet 4000 Series
Screw TF 08-32 TRPH 12
Screw 8-32 x 1/4” THMS
Cover Botm Hinge
Cover Top Hinge
Screw 8-32 x 3/8” FHM
Brkt Flavor Strip 2000 Series
Holder Flavor Label 3000 Series
Holder Flavor Label 4000 Series
Washer Plain Flat 10
Nut No. 10-32
Item Not Used

Manual Part No. 720901120IPL
4-25-2001 Rev: 12-3-01
IMI Cornelius Co., 2001

IMI CORNELIUS INC.
One Cornelius Place
Anoka, MN. 55303–6234
Telephone 1-800-238-3600
Facsimile 1-800-258-0255
www.cornelius.com

ILLUSTRATED PARTS LIST

QUANTUM SERIES JUICE DISPENSER

11

1

10
9

2

8
7

3
5

6

4
15

19
20
21
13
12
14
16
17
18
22

FIGURE 2. REFRIGERATION AND FRAME ASSEMBLY
Manual Part No. 720901120IPL
4-25-2001 Rev: 12-3-01
IMI Cornelius Co., 2001

4 of 16
Rev A

QUANTUM SERIES

IMI CORNELIUS INC.
One Cornelius Place
Anoka, MN. 55303–6234
Telephone 1-800-238-3600
Facsimile 1-800-258-0255
www.cornelius.com

ILLUSTRATED PARTS LIST

QUANTUM SERIES JUICE DISPENSER
(SEE FIGURE 2)
Item
No.

Part No.

Name

Item
No.

Refrigeration and Frame Ass’y
1

10

729011105

Kit Compressor, 120V 60HZ

729011106

Kit Compressor, 230V 50HZ

11

2

08474

Clip Spring

12

3

07301046

4
5

Part No.

Name

45373010

Solenoid Valve 120V 60HZ

45373020

Solenoid Valve 230V 50/60HZ
Box Elec Asy (See Figure 11)

45105100

Frame (1000 and 2000 Series)

Washer Ft .468 I.D.

45671100

Frame (3000 Series)

08467

Grommet Compressor

45405100

Frame (4000 Series)

45163001

Mtr Asy and Cond 115V 60HZ (See
Figure 9)

13

07115001

Screw TF 08-32 TRPH 12

14

60342002

Insert Thd 3/8-16

45163002

Mtr Asy and Cond 230V 50/60HZ
(See Figure 9)

15

2124713

Fitg Stght 3/8MF x 3/8MPT

6

7240691

Grommet

16

45091001

Valve Water Solenoid 24V

7

45148

Baffle Cond (1000 and 2000 Series)

17

03824001

Nut Jam 7/8-14

45670

Panel Baffle Cond (3000 Series)

18

30041001

Fitg Bulkhead

45448

Panel Baffle Cond (4000 Series)

19

04442

Spacer

8

289521

Screw No. 8-32 xy 3/8” HHS

20

0702609

Screw MA 8-32 BDPH 24

9

45073

Dryer

21

7221320

Strain Relief

22

46384

Cord Serv 115V 60HZ

46384001

Cord Serv 220V 50HZ

QUANTUM SERIES

5 of 16
Rev A

Manual Part No. 720901120IPL
4-25-2001 Rev: 12-3-01
IMI Cornelius Co., 2001

IMI CORNELIUS INC.
One Cornelius Place
Anoka, MN. 55303–6234
Telephone 1-800-238-3600
Facsimile 1-800-258-0255
www.cornelius.com

ILLUSTRATED PARTS LIST

QUANTUM SERIES JUICE DISPENSER

3

5

16

12
2
14

11
13
1
10

4
15

9
6
8

FIGURE 3. UPPER CABINET ASSEMBLY
Manual Part No. 720901120IPL
4-25-2001 Rev: 12-3-01
IMI Cornelius Co., 2001

6 of 16
Rev A

QUANTUM SERIES

IMI CORNELIUS INC.
One Cornelius Place
Anoka, MN. 55303–6234
Telephone 1-800-238-3600
Facsimile 1-800-258-0255
www.cornelius.com

ILLUSTRATED PARTS LIST

QUANTUM SERIES JUICE DISPENSER
(SEE FIGURE 3)
Item
No.

Part No.

Name

45027001

Bushing

7

11761

Harn Door (1000 Series: Not
Shown)

11762

Harn Door (2000 Series: Not
Shown)

11763

Harn Door (3000 Series: Not
Shown)

11823

Harn Door (4000 Series: Not
Shown)

Stud Latch No. 10-32

2

45119

Gasket Liner (1000 and 2000
Series)

5

Name

6

45051

4

Part No.

Upper Cabinet Asy
1

3

Item
No.

45662

Gasket Liner (3000 Series)

45419

Gasket Liner (4000 Series)

45141

Wrap Front (1000 and 2000 Series)

45657

Wrap Front (3000 Series)

45441

Wrap Front (4000 Series)

8

0704105

Screw No. 8-32 x 1/2” THMS

45142

Panel Botm Front (1000 Series)

9

0704101

Screw MA No. 8-32 TRPH 12

45207

Panel Botm Front (2000 Series)

10

04441

Spacer Lower

45664

Panel Botm Front (3000 Series)

11

0702609

Screw MA No. 8-32 BDPH 24

45407

Panel Botm Front (4000 Series)

12

46366

Bushing Hinge

45167

Liner Inner Asy (1000 Series)

13

45132

Brkt Conn Platform (1000 Series)

45220

Liner Inner Asy (2000 Series)

45232

Brkt Conn Platform (2000 and 4000
Series)

45654100

Liner Inner Asy (3000 Series)

45632

Brkt Conn Platform (3000 Series)

45420100

Liner Inner Asy (4000 Series)

14

0704001

Screw No. 8 x 3/8”

15

47121004

Magnet Door Seal

16

47121005

Magnet Door Seal (1000 and 2000
Series)

47121006

Magnet Door Seal (3000 Series)

QUANTUM SERIES

7 of 16
Rev A

Manual Part No. 720901120IPL
4-25-2001 Rev: 12-3-01
IMI Cornelius Co., 2001

IMI CORNELIUS INC.
One Cornelius Place
Anoka, MN. 55303–6234
Telephone 1-800-238-3600
Facsimile 1-800-258-0255
www.cornelius.com

ILLUSTRATED PARTS LIST

QUANTUM SERIES JUICE DISPENSER
27
7
19
21

25
2
22

20

27

23

26

24

18
12
4

6
9
27
11
8
10
27

1
3
16
17
15
5
13
14
18

27

28

FIGURE 4. PLATFORM ASSEMBLY
Manual Part No. 720901120IPL
4-25-2001 Rev: 12-3-01
IMI Cornelius Co., 2001

8 of 16
Rev A

QUANTUM SERIES

IMI CORNELIUS INC.
One Cornelius Place
Anoka, MN. 55303–6234
Telephone 1-800-238-3600
Facsimile 1-800-258-0255
www.cornelius.com

ILLUSTRATED PARTS LIST

QUANTUM SERIES JUICE DISPENSER
(SEE FIGURE 4)
Item
No.

Part No.

Name

Item
No.

Part No.

Name

45115

Platform Asy (1000 Series)

14

45047

Guide Latch

45215

Platform Asy (2000 and 4000
Series)

15

45048

Washer Latch

16

720800077

Rivet Latch

45315

Platform Asy (3000 Series)

17

45114

Platform (1000 Series)

1

0704101

Screw MA 8-32 TRPH 12

45214

Platform (2000 and 4000 Series)

2

71822081

Washer Holdown

45314

Platform (3000 Series)

3

309852000

Clamp

18

07032001

Screw No. 8-18 x 7/16”

4

45026

Adapter Bottle Asy (See Figure 5)

19

45173

Tube Asy Suction (1000 Series)

5

45033

Support Bottle Right

45276

6

45034

Support Bottle Left

Tube Asy Suction (2000 and 4000
Series)

7

45391001

Adapter Caddy Support (1000
Series)

45068003

Tube Asy Suction (3000 Series)

45069

45391002

Adapter Caddy Support (2000 and
4000 Series)

Line Discharge Asy (1000 and 3000
Series)

45273

45391003

Adapter Caddy Support (3000
Series)

Tube Asy Discharge (2000 and 4000
Series)

45160

Brkt Botl Adapter (1000 Series)

45137

Panel Splash Platform (1000 Series)

7245262

45236

Panel Splash Valves (2000 and
4000 Series)

Brkt Support Botl Adap (2000 and
4000 Series)

45339

Brkt Caddy Support (3000 Series)

45345004

Cover Platform (2000 and 4000
Series)

22

398033000

O-Ring .239 I.D.

7245036

Panel Splash Valves (3000 Series)

23

48195006

Clamp Hose

45345003

Cover Platform (3000 Series)

24

481950062

Clamp

9

45185

Pump and Mtr Asy (See Figure 7)

25

45275

Tube Asy Discharge (2000 and 4000
Series)

10

7245174

Manifold Asy Water (1000 Series)

26

45068001

Line Suct Asy (3000 Series)

45274

Manifold Asy Water (2000 and 4000
Series)

45277

Tube Asy Suction (2000 and 4000
Series)

45041

Manifold Asy Water (3000 Series)

45068002

11

45283

Bushing

Tube Asy Center Suction (3000
Series)

12

45045

Block Valve Asy

27

0704001

Screw No. 8-x 3/8”

13

45046

Latch

28

0704105

Screw No. 8-32 x 1/2” THMS

8

QUANTUM SERIES

20

21

9 of 16
Rev A

Manual Part No. 720901120IPL
4-25-2001 Rev: 12-3-01
IMI Cornelius Co., 2001

IMI CORNELIUS INC.
One Cornelius Place
Anoka, MN. 55303–6234
Telephone 1-800-238-3600
Facsimile 1-800-258-0255
www.cornelius.com

ILLUSTRATED PARTS LIST

QUANTUM SERIES JUICE DISPENSER
13
7
28

5
23

4
9

12
27

6
3

22
10
21
20
2
24

25
26

23

8

23
28
11
15

16

19

1

17

14

18
23

FIGURE 5. VALVE BLOCK ASSEMBLY
Item
No.

Part No.

Name

Item
No.

Part No.

Name

45045

Block Valve Asy

15

45180

Spring Acutuator

1

45177

Holder Poppet Seal

16

45189

Poppet

2

0720406

Nut No. 10-32

17

45179

Support Diaphram

3

71815321

Ring Retaining

18

45195

Plate Front Valve Block

4

7215323

Armature

19

45186

Spring

5

18070002

Gasket Rubber Valve Block

20

48520001

Coil Asy 24V DC

6

18367

Spring Armature

21

48978

Flo Cntl Bonnet Asy

7

19695001

Guide

22

48979103

Sleeve and Piston Asy Water

8

31525021

O-Ring 1.114 I.D.

60281001

Sleeve Syrup Ceramic

9

18071

Seat Armature

23

07032001

Screw No 8-18 x 7/16

10

48258005

Spring Syrup

24

16779003

Frame Solenoid

11

45192

Valve Body Mixing

25

49612

Port Valve Water

12

45193

Valve Body Water

26

31525020

O-Ring .176 I.D.

13

45029

Plate Coil Retainer

27

31525060

O-Ring .459 I.D.

14

47011

Diaph Valve

28

48378

Brkt Support Valve

Manual Part No. 720901120IPL
4-25-2001 Rev: 12-3-01
IMI Cornelius Co., 2001

10 of 16
Rev A

QUANTUM SERIES

IMI CORNELIUS INC.
One Cornelius Place
Anoka, MN. 55303–6234
Telephone 1-800-238-3600
Facsimile 1-800-258-0255
www.cornelius.com

ILLUSTRATED PARTS LIST

QUANTUM SERIES JUICE DISPENSER
Item
No.

11

Part No.

Name
1

45026

Adapter Bottle Asy

1

45060001

Adapter Caddy Top

2

45060002

Adapter Caddy Run and Flush

3

45060003

Adapter Caddy Bottom

4

31525062

O-Ring .118 I.D.

5

31525014

O-Ring .489 I.D.

6

31525061

O-Ring 1.489 I.D.

7

07015001

Screw No. 8-18 x 3/4”

8

45043

Pin Sensor Soldout

9

31525064

O-Ring .488 I.D.

10

60068021

Switch Snap Portion Control

11

45076

Pin Actuator

12

60067086

Screw No. 2-56 x 7/16”

13

45084001

Plate Support Bottle

8
12
5
10
6

2
9

6
4
3
7
13

FIGURE 6. BOTTLE ADAPTER ASSEMBLY
6
5
3
1

7
2
7

4

8

FIGURE 7. PUMP AND MOTOR ASSEMBLY
Item
No.

Part No.

Name

45185

Pump and Motor Asy

1

45016001

Motor Pump

2

45728001

Rotor Asy

3

45050

Block Asy Mtg Pump and Motor

4

45017001

Screw Thumb Pump

5

0702905

Screw No. 8-32 x 3/4” FHMS

QUANTUM SERIES

Item
No.

11 of 16
Rev A

Part No.

Name

6

45037001

Tubg Neoprene .250 I.D. (Sold by
the Foot)

7

45727

Body Pump Asy

8

45283

Bushing

9

45098

Kit Pump Tube Replacement

Manual Part No. 720901120IPL
4-25-2001 Rev: 12-3-01
IMI Cornelius Co., 2001

IMI CORNELIUS INC.
One Cornelius Place
Anoka, MN. 55303–6234
Telephone 1-800-238-3600
Facsimile 1-800-258-0255
www.cornelius.com

ILLUSTRATED PARTS LIST

QUANTUM SERIES JUICE DISPENSER
Item
No.

Part No.
45241
45390

Name
4

Door Asy Back (1000 and 2000
Series)
Door Asy Back (3000 Series)

3

45470

Door Asy Back (4000 Series)

1

45281

Panel Rear Door (1000 and 2000
Series)

2

45386

Panel Rear Door (3000 Series)

45477

Panel Rear Door (4000 Series)

2

7233023

Switch Safety

3

7245120

Gasket Door Mag (1000 and 2000
Series)

45320

Gasket Door Mag (3000 Series)

45431

Gasket Door Mag (4000 Series)

7245780

Frame Door Gasket (1000 and 2000
Series)

7245781

Frame Door Gasket (3000 Series)

7245782

Frame Door Gasket (4000 Series)

5

7245779

Rivet .236 Dia.

6

45432

Switch Rocker

1

4

5

6

FIGURE 8. REAR DOOR ASSEMBLY
Item
No.

1

Part No.

Name

45175001

Motor Asy Fan 9W 120V 60HZ

45175002

Motor Asy Fan 9W 230V 50/60HZ

0726802

Nut Tinnerman

2

45159

Panel Splash

3

41757

Washer

4

48004

Motor Fan 9W 120V 60HZ

48013

Motor Fan 9W 230V 50/60HZ

5

45168

Blade Fan

6

96285001

Screw No. 8-36 x 3/8”

7

45161

Cond Coil

1
3
2

7

5

4

6

FIGURE 9. CODENSER MOTOR ASSEMBLY
Manual Part No. 720901120IPL
4-25-2001 Rev: 12-3-01
IMI Cornelius Co., 2001

12 of 16
Rev A

QUANTUM SERIES

IMI CORNELIUS INC.
One Cornelius Place
Anoka, MN. 55303–6234
Telephone 1-800-238-3600
Facsimile 1-800-258-0255
www.cornelius.com

ILLUSTRATED PARTS LIST

QUANTUM SERIES JUICE DISPENSER

1

4
9

3
6
2
5
7

FIGURE 10. DOOR COVER ASSEMBLY
Item
No.

Part No.

Name

45296006

Cover Asy Merchndsr Push Button
(2000 Series)

45296007

Cover Asy Merchndsr Portion
Control (2000 Series)

45296009

Cover Asy Merchndsr Portion
Control, Illuminated (2000 Series)

45394005

Cover Asy Merchndsr Push Button
(3000 Series)

45394007

Cover Asy Merchndsr Push Button,
Illuminated (3000 Series)

45394008

Cover Asy Merchndsr Portion
Control, Illuminated (3000 Series)

Item
No.
1

Cover Merchndsr (2000 Series)

45224005

Cover Merchndsr Illuminated (2000
Series)

45377004

Cover Merchndsr (3000 Series)

45377005

Cover Merchndsr Illuminated (3000
Series)

45472004

Cover Merchndsr (4000 Series)

45472005

Cover Merchndsr Illuminated (4000
Series)

2

07301029

Washer Ft .125 I.D.

3

0712901

Screw No. 4 x 5/16”

45018001

Board Push Button

49280001

Portion Cntl Board

49230

Overlay Asy Push Button

49231

Overlay Asy Portion Control

7245399

Bezel Push Button

45398

Bezel Portion Control

7

45435

Lock and Keys

8

11771

Jumper Asy Strain Relief
(Not Shown)

9

04037

Clip

Cover Asy Merchndsr Push Button
(3000 Series)

4

45481007

Cover Asy Merchndsr Portion
Control (4000 Series)

5

45481008

Cover Asy Merchandsr Push Button,
Illuminated (4000 Series)

QUANTUM SERIES

6

Cover Asy Merchandsr Portion
Control, Illuminated (4000 Series)

13 of 16
Rev A

Name

45224004

45481006

45481009

Part No.

Manual Part No. 720901120IPL
4-25-2001 Rev: 12-3-01
IMI Cornelius Co., 2001

IMI CORNELIUS INC.
One Cornelius Place
Anoka, MN. 55303–6234
Telephone 1-800-238-3600
Facsimile 1-800-258-0255
www.cornelius.com

ILLUSTRATED PARTS LIST

QUANTUM SERIES JUICE DISPENSER

10

2
14
8

9

3
11
1

5
4
6
7
12
13

FIGURE 11. ELECTRICAL BOX (DC) ASSEMBLY
Item
No.

Part No.

Name

Item
No.

Box Elec Asy
1

07061001

Screw No. 10 x 3/8”

2

0733903

Bushing Snap

3

07115001

Screw TF 8-32 TRPH 12

4

0734801

Rivet Pop

5

59328001

Fuse 6.25 Amp

6

7245059

Fuseholder

7

45106

Box Elec (1000 and 2000 Series)

45673

Box Elec (3000 Series)

45414

Box Elec (4000 Series)

Manual Part No. 720901120IPL
4-25-2001 Rev: 12-3-01
IMI Cornelius Co., 2001

8

14 of 16
Rev A

Part No.

Name

45138

Reg Voltage Asy (1000 Series)

45238

Reg Voltage Asy (2000 and 4000
Series)

45674

Reg Voltage Asy (3000 Series)

9

46306

Thermostat Concentrate

10

46307

Thermostat Water Evap

11

49273

Block Term

12

45432

Switch

13

07061003

Screw No. 10 x 3/8” HHWF

14

348871

Screw No. 8-32 x 1/4”

QUANTUM SERIES

IMI CORNELIUS INC.
One Cornelius Place
Anoka, MN. 55303–6234
Telephone 1-800-238-3600
Facsimile 1-800-258-0255
www.cornelius.com

ILLUSTRATED PARTS LIST

QUANTUM SERIES JUICE DISPENSER
Item
No.

Part No.

6

Name
Box Elec Asy

1

45110

Box Elec (1000 and 2000 Series)

45668

Box Elec (3000 Series)

45410

Box Elec (4000 Series)

2

07061001

Screw No. 10 x 3/8”

3

49273

Block Term

4

46308

Relay Start 115V 60HZ

463081

Relay Start 220V 50HZ

5

0735201

Bushing

6

07061003

Screw No. 10 x 3/8”

7

45028

Transfrmr 115V 60HZ (Not Shown)

45028001

Transfrmr 240V 50HZ (Not Shown)

60600002

Ballast (Not Shown)

8

3
4
2

5
1

FIGURE 12. ELECTRICAL BOX (AC) ASSEMBLY

QUANTUM SERIES

15 of 16
Rev A

Manual Part No. 720901120IPL
4-25-2001 Rev: 12-3-01
IMI Cornelius Co., 2001

IMI CORNELIUS INC.
One Cornelius Place
Anoka, MN. 55303–6234
Telephone 1-800-238-3600
Facsimile 1-800-258-0255
www.cornelius.com

ILLUSTRATED PARTS LIST

QUANTUM SERIES JUICE DISPENSER
Item
No.

4

Part No.

Name

45138

Reg Voltage Asy (1000 Series)

45238

Reg Voltage Asy (2000 and 4000
Series)

45338

Reg Voltage Asy (3000 Series)

45162

Brkt Voltage Regulator

45675

Brkt Voltage Regulator (3000 Series)

2

45056

Support P.C. Board

3

45012002

Board Voltage Regulator

4

45004

Kit Mounting

5

45004001

Insulator Voltage Reg

1

5

1
2
3
4

FIGURE 13. VOLTAGE REGULATOR ASSEMBLY
Item
No.

Part No.

Name

45190

Tank Asy

1

46433

Retainer

2

463571

Tank Ball Check

3

7229192

Gasket Adaptor

4

31525010

O-Ring .737 I.D.

7

5

1836701

Spring Adapter

8

6

7245246

Fitg Adaptor Tank

3
1

7

45260001

Lid Tank

8

45260

Tank

9

45248

Adaptor Asy Tank

9

5
2
4

6

FIGURE 14. TANK ASSEMBLY

Manual Part No. 720901120IPL
4-25-2001 Rev: 12-3-01
IMI Cornelius Co., 2001

16 of 16
Rev A

QUANTUM SERIES



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : No
Page Count                      : 37
XMP Toolkit                     : XMP toolkit 2.9.1-13, framework 1.6
About                           : uuid:1a0a5227-4164-412a-81bc-ec1cf1823974
Producer                        : Acrobat PDFWriter 4.0 for Windows NT
Modify Date                     : 2005:12:12 16:14:45-05:00
Create Date                     : 2004:11:23 10:55:09Z
Metadata Date                   : 2005:12:12 16:14:45-05:00
Creator Tool                    : Adobe FrameMaker - [G:\Publications\Documents\Wilshire\Quantum\720901120 Quantum Manual 11-29-00.fm]
Document ID                     : uuid:abd55e3e-2e67-429a-a48b-4763e3bdf6b5
Format                          : application/pdf
Title                           : G:\Publications\Documents\Wilshire\Quantum\720901120 Quantum Manual 11-29-00.prn.pdf
Creator                         : lisae
Author                          : lisae
EXIF Metadata provided by EXIF.tools

Navigation menu