Corning Optical Communication HXCPL70MAM HX HIGH POWER DAS REMOTE UNIT MIMO User Manual MbileAccessHX 2W UM
Corning Optical Communication Wireless HX HIGH POWER DAS REMOTE UNIT MIMO MbileAccessHX 2W UM
Contents
- 1. Users Manual
- 2. User Manual
Users Manual
MobileAccessHX™ DAS System Installation and Configuration Guide P/N: 709C006801 REV: A0 Date: FEB, 2012 Preface Corning MobileAccess 8391 Old Courthouse Road, Suite 300, Vienna, VA 22182 Tel: +1(866)436-9266, +1(703)848-0200 TAC: +1(800)787-1266, Fax: +1(703)848-0280 www.corning.com/mobileaccess MobileAccessHX and MobileAccess are trademarks of Corning MobileAccess, Inc. Corning MobileAccess is a trademark of Corning Incorporated. Corning MobileAccess Inc. is a wholly-owned affiliate of Corning Incorporated. MobileAccessHX Installation and Configuration Guide II Preface P r e fa c e Ma t e r ia l © Copyright 2011, MobileAccess All Rights Reserved. This document may contain confidential and proprietary information of Corning MobileAccess, Inc. (“MobileAccess”) and may not be copied, transmitted, stored in a retrieval system or reproduced in any format or media, in whole or in part, without the prior written consent of MobileAccess. Information contained in this document supersedes any previous manuals, guides, specifications, data sheets or other information that may have been provided or made available to the user. This document is provided for informational purposes only, and Corning MobileAccess does not warrant or guarantee the accuracy, adequacy, quality, validity, completeness or suitability for any purpose of the information contained in this document. Corning MobileAccess reserves the right to make updates, improvements and enhancements to this document and the products to which it relates at any time without prior notice to the user. CORNING MOBILEACCESS MAKES NO WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, WITHOUT LIMITATION, THOSE OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, WITH RESPECT TO THIS DOCUMENT OR ANY INFORMATION CONTAINED HEREIN. Policy for Warrantee and Repair Corning MobileAccess tests and inspects all its products to verify their quality and reliability. Corning MobileAccess uses every reasonable precaution to ensure that each unit meets their declared specifications before shipment. Customers should advise their incoming inspection, assembly, and test personnel about the precautions required in handling and testing our products. Many of these precautions can be found in this manual. The products are covered by the following warranties: General Warranty Corning MobileAccess warrants to the original purchaser all standard products sold by Corning MobileAccess to be free of defects in material and workmanship for one (1) year from date of shipment from Corning MobileAccess. During the warranty period, MobileAccess will repair or replace any product that Corning MobileAccess proves to be defective. This warranty does not apply to any product that has been subject to alteration, abuse, improper installation or application, accident, electrical or environmental over-stress, negligence in use, storage, transportation or handling. Specific Product Warranty Instructions All Corning MobileAccess products are warranted against defects in workmanship, materials and construction, and to no further extent. Any claim for repair or replacement of units found to be defective on incoming inspection by a customer must be made within 30 days of receipt of shipment, or within 30 days of discovery of a defect within the warranty period. This warranty is the only warranty made by MobileAccess and is in lieu of all other warranties, expressed or implied. Corning MobileAccess sales agents or representatives are not authorized to make commitments on warranty returns. Returns In the event that it is necessary to return any product against above warranty, the following procedure shall be followed: 1. Return authorization is to be received from MobileAccess prior to returning any unit. Advise Corning MobileAccess of the model, serial number, and discrepancy. The unit may then be forwarded to Corning MobileAccess, transportation prepaid. Devices returned collect or without authorization may not be accepted. 2. Prior to repair, Corning MobileAccess will advise the customer of our test results and any charges for repairing customer-caused problems or out-of-warranty conditions etc. MobileAccessHX Installation and Configuration Guide III Preface 3. Repaired products are warranted for the balance of the original warranty period, or at least 90 days from date of shipment. Limitations of Liabilities Corning MobileAccess's liability on any claim, of any kind, including negligence for any loss or damage arising from, connected with, or resulting from the purchase order, contract, quotation, or from the performance or breach thereof, or from the design, manufacture, sale, delivery, installation, inspection, operation or use of any equipment covered by or furnished under this contact, shall in no case exceed the purchase price of the device which gives rise to the claim. EXCEPT AS EXPRESSLY PROVIDED HEREIN, MOBILEACCESS MAKES NO WARRANTY, EXPRESSED OR IMPLIED, WITH RESPECT TO ANY GOODS, PARTS AND SERVICES PROVIDED IN CONNECTION WITH THIS AGREEMENT INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. MOBILEACCESS SHALL NOT BE LIABLE FOR ANY OTHER DAMAGE INCLUDING, BUT NOT LIMITED TO, INDIRECT, SPECIAL OR CONSEQUENTIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH FURNISHING OF GOODS, PARTS AND SERVICE HEREUNDER, OR THE PERFORMANCE, USE OF, OR INABILITY TO USE THE GOODS, PARTS AND SERVICE Reporting Defects The units were inspected before shipment and found to be free of mechanical and electrical defects. Examine the units for any damage that may have been caused in transit. If damage is discovered, file a claim with the freight carrier immediately. Notify Corning MobileAccess as soon as possible. NOTE: Keep all packing material until you have completed the inspection RF Safety NOTE: Keep all packing material until you have completed the inspection WARNING: To comply with FCC RF exposure compliance requirements, antennas used for this product must be fixed mounted on indoor permanent structures, providing a separation distance of more than 115 cm from all persons during normal operation. WARNING: Antenna gain should not exceed 10 dBi. WARNING: Each individual antenna used for this transmitter must be installed to provide a separation distance greater than 115 cm or more from all persons and must not be co-located with any other antenna for meeting RF exposure requirements. WARNING: The design of the antenna installation needs to be implemented in such a way so as to ensure RF radiation safety levels and non-environmental pollution during operation. MobileAccessHX Installation and Configuration Guide IV Preface ATTENTION: COMPLIANCE WITH RF SAFETY REQUIREMENTS: CORNING MOBILEACCESS PRODUCTS HAVE NO INHERENT SIGNIFICANT RF RADIATION. THE RF LEVEL ON THE DOWN LINK IS VERY LOW AT THE DOWNLINK PORTS. THEREFORE, THERE IS NO DANGEROUS RF RADIATION WHEN THE ANTENNA IS NOT CONNECTED. Laser Safety FIBER OPTIC PORTS OF THE MOBILEACCESSHX EMIT INVISIBLE LASER RADIATION AT THE 1310/1550 NM WAVELENGTH WINDOW . TO AVOID EYE INJURY NEVER LOOK DIRECTLY INTO THE OPTICAL PORTS, PATCHCORDS OR OPTICAL CABLES. DO NOT STARE INTO BEAM OR VIEW DIRECTLY WITH OPTICAL INSTRUMENTS. ALWAYS ASSUME THAT OPTICAL OUTPUTS ARE ON. ONLY TECHNICIANS FAMILIAR WITH FIBER OPTIC SAFETY PRACTICES AND PROCEDURES SHOULD PERFORM OPTICAL FIBER CONNECTIONS AND DISCONNECTIONS OF THE MOBILEACCESSHX MODULES AND THE ASSOCIATED CABLES. THE MOBILEACCESS HX COMPLIES WITH CDRH21 CFR 1040.10 AND 1040.11 EXCEPT FOR DEVIATIONS PURSUANT TO LASER NOTICE NO. 50 (JULY 26, 2001) & IEC 60825-1, AMENDMENT 2 (JAN. 2001) & EN 60825-1. Care of Fiber Optic Connectors DO NOT REMOVE THE PROTECTIVE COVERS ON THE FIBER OPTIC CONNECTORS UNTIL A CONNECTION IS READY TO BE MADE. DO NOT LEAVE CONNECTORS UNCOVERED WHEN NOT CONNECTED. THE TIP OF THE FIBER OPTIC CONNECTOR SHOULD NOT COME INTO CONTACT WITH ANY OBJECT OR DUST. REFER TO THE CLEANING PROCEDURE FOR INFORMATION ON THE CLEANING OF THE FIBER TIP. MobileAccessHX Installation and Configuration Guide Preface Safety Instructions Installation Safety Guidelines Follow all safety regulations when installing the HX system Only qualified personnel are authorized to install and maintain the HX system The equipment is intended for installation in restricted access locations only • • • RF Safety WARNING! To comply with FCC RF exposure compliance requirements, antennas used for this product must be fixed mounted on indoor permanent structures, providing a separation greater than 115 cm from all persons during normal operation. 1. Each individual antenna used for this transmitter must be installed to provide a separation distance greater than 115 cm or more from all persons and must not be co-located with any other antenna for meeting RF exposure requirements. 2. The design of the antenna installation needs to be implemented in such a way so as to ensure RF radiation safety levels and non-environmental pollution during operation. Compliance with RF safety requirements: • Corning MobileAccess products have no inherent significant RF radiation. • The RF level on the downlink is very low at the downlink ports. Therefore, there is no dangerous RF radiation when the antenna is not connected. Power Requirements for DC Inputs WARNING! • Only use a special DC supply cable with four connectors • Always keep DC IN connectors connected during the product operation • Disconnect all power from the equipment by means of an external circuit breaker before connecting or disconnecting the DC IN connectors. MobileAccessHX Installation and Configuration Guide VI Preface Standards and Certification Corning MobileAccess products have met the approvals of the following certifying organizations: Company Certification ISO ISO 9001: 2000 and ISO 13485: 2003 Product Certifications US Europe Radio Equipment and Systems FCC 47 CFR part 22 – for CELL Frequency Band FCC 47 CFR part 24 – for PCS Frequency Band FCC 47 CFR part 27 – for 700 LTE and AWS Frequency Bands EMC FCC 47 CFR part 15 Subpart B NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: - Reorient or relocate the receiving antenna. - Increase the separation between the equipment and receiver. -Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -Consult the dealer or an experienced radio/TV technician for help. Warning! Changes or modifications to this equipment not expressly approved by Mobile Access could void the user’s authority to operate the equipment. Radio Equipment Systems EN 301502 – for GSM/EGSM Frequency Bands EN 300609 – for DCS Frequency Band EN 301908 – for UMTS Frequency Band EMC EN 301 489 Safety EN 60950; UL 60950 CAN/CSA-C22.2 No.60950 Laser Safety CDRH 21 CFR 1040.10, 1040.11 (Except for deviations per notice No.50, July 26, 2001) IEC 60825-1, Amendment 2 (January 2001) EN 60825-1 MobileAccessHX Installation and Configuration Guide VII Preface About this Guide and Other Relevant Documentation This user guide describes how to perform the physical installation of the MobileAccessHX Indoor and Outdoor units. The installation procedures of other units (e.g. RIU, SC-450) relevant to the system are detailed in their user manuals (see Additional Relevant Documentation below). Additional Relevant Documents The following documents are required if the corresponding units are included in your system. Document Name RIU Installation and Configuration Guide SC-450 Installation and Configuration Guide MA Software Version Update Tool List of Acronyms BDA Bi-Directional Amplifier BTS Base Transceiver Station BTSC Base Transceiver Station Conditioner BU Base Unit DL Downlink HX High Power Transmission RIU Radio Interface Unit UL Uplink MobileAccessHX Installation and Configuration Guide VIII Table of Contents Preface Material .......................................................................................................................III Policy for Warrantee and Repair ......................................................................................................... III Safety Instructions ............................................................................................................................ VI Standards and Certification ............................................................................................................... VII About this Guide and Other Relevant Documentation ........................................................................ VIII List of Acronyms ............................................................................................................................. VIII Table of Contents.............................................................................................................................. IX Introduction to HX System ................................................................................................1 1.1 Features and Capabilities .............................................................................................................. 2 1.2 System Architecture ..................................................................................................................... 3 1.3 Application Topologies ................................................................................................................. 4 1.4 System Monitoring and Management............................................................................................. 4 1.5 HX Unit Interfaces ....................................................................................................................... 5 1.5.1 HX Indoor Interfaces .......................................................................................................... 5 1.5.1.1 HX Indoor SISO Internal and Front Panel Interfaces ................................................. 5 1.5.1.2 HX Indoor MIMO Internal and Front Interfaces ........................................................ 7 1.5.2 HX Outdoor Unit Interfaces ................................................................................................. 9 System Installation ..........................................................................................................10 2.1 HX Indoor Installation ................................................................................................................ 10 2.1.1 Unpacking and Inspection ................................................................................................. 10 2.1.2 Grounding ........................................................................................................................ 11 2.1.3 Mounting ......................................................................................................................... 11 2.1.3.1 Wallmount Installation .......................................................................................... 11 2.1.3.2 Rack Mount Installation ........................................................................................ 12 Rack Brackets .........................................................................................................................13 2.1.4 Connections ..................................................................................................................... 14 2.1.4.1 HX Indoor SISO Connections................................................................................. 14 2.1.4.2 HX Indoor MIMO Connections ............................................................................... 16 2.2 HX Outdoor Installation .............................................................................................................. 17 2.2.1 Unpacking and Inspection ................................................................................................. 17 2.2.2 Mounting ......................................................................................................................... 19 2.2.2.1 Wall Mount Installation ......................................................................................... 19 2.2.2.2 Pole Mount Installation ......................................................................................... 21 2.2.3 Connections ..................................................................................................................... 24 MobileAccessHX Installation and Configuration Guide IX Preface Commissioning MA Head-End ........................................................................................25 3.1 Initial Controller Setup ............................................................................................................... 25 3.1.1 Open a Session to the Controller ....................................................................................... 25 3.1.2 IP Address Configuration .................................................................................................. 27 3.2 Configure Controller Settings ...................................................................................................... 29 3.3 Device Configuration and Preparation.......................................................................................... 29 3.4 RIU Configuration ...................................................................................................................... 31 3.4.1 Configuration for all BTSCs (other than LTE 700) ................................................................ 31 3.4.2 BTSC LTE 700 MHz ........................................................................................................... 32 3.5 Base Unit Configuration Dialog.................................................................................................... 35 Provisioning the MobileAccessHX..................................................................................37 4.1 Accessing HX Management Options............................................................................................. 37 4.2 Basic Setup Procedure ................................................................................................................ 38 Appendix A: System Specifications ......................................................................................43 Appendix B: Ordering Information ........................................................................................47 Appendix C: Part Numbers for HX Outdoor Weather Resistant Connectors ......................50 Connector ................................................................................................................................50 Manufacturer Name.................................................................................................................50 Manufacturer P/N ....................................................................................................................50 Description ..............................................................................................................................50 Appendix D: Site Preparation.................................................................................................51 Installation Requirements .................................................................................................................. 51 Coaxial Cable Connections ................................................................................................................. 51 Power Consumption, Connections and Power Supplies ........................................................................ 53 Installation Conventions .................................................................................................................... 54 MobileAccessHX Installation and Configuration Guide 1 Introduction to HX System MobileAccessHX is a high power, Distributed Antenna System (DAS) solution for indoors or outdoors (future option). It is a fiber-fed, compact, scalable multi-service platform designed to provide complete RF open space coverage for large scale public venues, such as campuses, stadiums, convention centers, hotels, airports, and train stations. HX supports multiple wireless technologies and operator services over a single broadband infrastructure. Using low loss fiber optic cabling, remote units can cover distances of up to 2Km from the BTS signal sources at the head-end. Front-end wireless RF services are routed over optic fibers to HX series remote units, which are securely located at each remote location. These modular service aggregation platforms precisely combine multiple wireless service signals for simultaneous distribution over a common broadband infrastructure. The solution can be deployed in new sites or alongside existing MobileAccess1000 (MA1000) and/or MobileAccess2000 (MA2000) systems, sharing a common head-end and element management system (EMS). Alongside MA1000/MA2000 deployments, MobileAccessHX provides a comprehensive indoor and outdoor coverage solution for varying site requirements, supporting everything from high-rise buildings and campus topologies, to stadiums and airports. HX Remote Unit – Outdoor Model HX Remote Unit – Indoor Model Figure 1-1. HX Indoor Model and HX Outdoor Model MobileAccessHX Installation and Configuration Guide Introduction to HX System 1.1 Features and Capabilities Features and Capabilities • Multi-Service Platform: Accommodates GSM, UMTS, HSPA, LTE, EDGE, EV-DO, AWS, and more. Provides MIMO configuration for LTE700, AWS, and UMTS band. • Cost-Effective High Power: Optimizes and reduces the number of antennas required to cover open areas by offering up to 33dBm (2W) composite power per frequency band. • Indoor Models: Supports either SISO or MIMO service in a single compact enclosure. • Outdoor Models: The outdoor model enclosures are compliant with IP65/NEMA standards. • Carrier-Grade Operation: Advanced signal handling and management ensures carriergrade performance in multi-operator deployments. • Design and Deployment Flexibility: Remote unit supports both SM and MM fiber connections, and are available in AC or DC power supply options. Antenna splitting schemes are possible due to the higher power output capability. • Backwards Compatible: Connects to an existing MobileAccess1000 or MobileAccess2000 deployment and shares a common head-end and Element Management System (EMS) in a single deployment. MobileAccessHX Installation and Configuration Guide Introduction to HX System 1.2 System Architecture System Architecture MobileAccessHX provides a complete solution consisting of HX remote units at the remote locations, and head-end elements, which are shared with any existing or new MA1000/MA2000 deployment. In the downlink, at the head-end, the BTS or BDA signal is conditioned by the RIU, ensuring a constant RF level. The conditioned signal is then converted by the Base Unit to an optical signal for transport over single or multi-mode fiber to the HX remote units, which are located at the remote locations. In the uplink, the process is reversed. The SC-450 Controller enables local and remote management, as well as controls all MA1000, MA2000, and HX elements from a single, centralized location. The MobileAccessHX Remote Unit (indoor-SISO/MIMO and outdoor-SISO models) consists of a compact enclosure that houses the RF module, power elements, and the required interfaces. The RF module supports three bands (GSM, DCS, and UMTS) and two types of quad bands (Type 1: LTE700, CELL, PCS, and AWS or Type 2: CELL, EGSM, DCS, or UMTS) All mobile services are combined and distributed through a single antenna port over antennas installed at the remote locations. MobileAccessHX architecture including existing MA2000 / MA1000, with a common head-end. Figure 1-2. System Architecture MobileAccessHX Installation and Configuration Guide Introduction to HX System 1.3 Application Topologies Application Topologies MobileAccessHX can be installed in various site topologies, where the setup procedure varies accordingly: • • • 1.4 High power coverage via a single antenna - used for open area, stadium, parking lots, etc. RF signal is distributed over several antennas via splitters Special coverage requirements using directional antennas System Monitoring and Management The MobileAccessHX Remote Unit is centrally managed via the MobileAccess SC-450 Controller. Note that MobileAccessHX is not connected directly to the controller. It is connected to the Base Unit (that is connected to the controller). Thus, the controller monitors views and manages the HX via the Base Unit to which the HX is connected. The following shows the Config(uration) tab of the selected HX unit. The system configuration and management is described in Chapter 4. Figure 1-3: Example of HX (Indoor SISO) Configuration Tab MobileAccessHX Installation and Configuration Guide Introduction to HX System 1.5 HX Unit Interfaces HX Unit Interfaces The HX antenna port is located externally. All other interfaces such as F/O connections, power connections, etc. are located inside the cabinet and are accessed by opening the cabinet door. 1.5.1 HX Indoor Interfaces 1.5.1.1 HX Indoor SISO Internal and Front Panel Interfaces The HX Indoor antenna port is located externally. All other interfaces such as F/O connections, power connections, etc. are located inside the cabinet and are accessed by opening the cabinet door. The HX Model Components: • • • • • Quad-band Service Module – Connects to the Base Unit using a single fiber pair and supports up to (4) services External Amplifier Blade – (2) External Amplifiers are mounted on each of the (2) blades and provide the additional amplification on the DL signals coming from the Quad-band Service Module to the Multiplexer 8:1 Multiplexer – Combines UL and DL signals of the (4) bands, while providing the proper filtering, into a single duplexed antenna port Power Supply – Local AC or Remote DC power feed (model depended) Duplexed Antenna Port – Interface to RF antennas Note: More information on the components and LEDs is provided in the tables in the next page. Fiber optic port MobileAccess Quad-band Service Module (supports up to four services) RS-232 local craft Duplexed antenna port External Amplifiers blade 8:1 Multiplexer Power connection (model dependent) Figure 1-4. Example of Indoor HX Remote Unit Open (Front view) MobileAccessHX Installation and Configuration Guide Introduction to HX System HX Unit Interfaces The HX Indoor rear panel includes the grounding lug and ventilation holes. The figure below illustrates a rear panel of a unit on which wall mount brackets are already assembled. (Each unit is provided with both wall- and rack-mount brackets. Note: The rear interfaces are the same for both HX Indoor SISO and MIMO cabinets. Wall Mount Brackets Fans Holes Grounding Lug Figure 1-4. Example of Indoor HX Remote Unit (Rear View) The following tables provide a description of the HX indoor type connectors and LEDs. Connector Description F/O SC/APC fiber-optic connector for either SM or MM fibers Antenna N-Type female 50Ω duplexed connector for RF antenna AC PWR 110/220 VAC power feed DC Direct 48VDC power feed RS-232 Local craft connector Grounding Grounding lug Table 1-1. Connector Descriptions Name Power Comm Link Description Device is powered Color GREEN Status Steady On Power not supplied to the unit When connected and discovered by an OPTM (BU) When device is powered on but no external communication is received No Optical link is present Low optical link level from OPTM Normal optical link level from OPTM GREEN GREEN Off Blink per communication attempt Steady Slow Blink GREEN GREEN GREEN GREEN Off Blink Steady On Table 1-2. LED Descriptions MobileAccessHX Installation and Configuration Guide Introduction to HX System 1.5.1.2 HX Unit Interfaces HX Indoor MIMO Internal and Front Interfaces The HX Indoor antenna ports (2) are located externally. All other interfaces such as F/O connections, power connections, etc. are located inside the cabinet and are accessed by opening the cabinet door. The HX Indoor MIMO model includes the following main components: • • • • • • RF Modules: • Quad-band Service Module – connects to the Base Unit using a single fiber pair and supports up to four services (SISO/MIMO1) • Additional RF module providing support for two MIMO2 services – connects to the Base Unit using a single fiber pair External Amplifiers blade – 2 External Amplifiers are mounted on each of the 2 blades and provide the additional amplification on the DL signals coming from the Quad-band Service Module top the Multiplexer 8:1 Multiplexer – combines UL & DL signals of the 4 bands, while providing the proper filtering, into a duplexed antenna port Duplexer - combines UL & DL signals of the 2 additional MIMO2 bands, while providing the proper filtering, into the MIMO2 duplexed antenna port Power supply – local AC or Remote DC power feed (model dependent) Duplexed antenna ports (MIMO1 and MIMO2) – interface to RF antennas Note: More information on the components and LEDs is provided in the tables in the next page. Quad-Band RF Module Fiber optic port Fiber optic port MobileAccess RF Module supporting MIMO services Duplexer 4:1 RS-232 local craft (MIMO1) MobileAccess Quad-band Service Module (supports up to four services) Duplexed antenna port RS-232 local craft (MIMO2) External Amplifiers blade 8:1 Multiplexer AC power DC power location (for relevant models) Figure 1-5. Example of HX Indoor MIMO Remote Unit Internal View (Front) MobileAccessHX Installation and Configuration Guide Introduction to HX System HX Unit Interfaces The following tables provide a description of the HX indoor type connectors and LEDs. Connector Description F/O SC/APC fiber-optic connector for either SM or MM fibers (1 for each RF service module) Antenna N-Type female 50Ω duplexed connector for RF antenna (MIMO1 and MIMO2) AC PWR 110/220 VAC power feed DC Direct 48VDC power feed RS-232 Local craft connector Table 1-3. Connector Descriptions Name Description Color Status Power Device is powered GREEN Steady On Power not supplied to the unit GREEN Off When connected and discovered by an OPTM (BU) GREEN Blink per communication attempt When device is powered on but no external communication is received GREEN Steady Slow Blink No Optical link is present GREEN Off Low optical link level from OPTM GREEN Blink Normal optical link level from OPTM GREEN Comm Link Steady On Note: LEDs the same for each RF module. Table 1-4. LED Descriptions MobileAccessHX Installation and Configuration Guide Introduction to HX System 1.5.2 HX Unit Interfaces HX Outdoor Unit Interfaces The HX Outdoor interfaces are located on the underside panel of the unit (facing down when unit is mounted). The unit interfaces include the RF, power and optical link connectors. The power, RS232 and F/O connectors are special weather resistant connectors. You may either order ready cables from MobileAccess or refer to the manufacturer Part Numbers for generating the required cables (Appendix C). RS232 port F/O UL PWR LED AC/DC Power (model dependent) F/O DL RF antenna Connectors located on underside panel Figure 1-6: HX Outdoor Interfaces – Underside Panel The following tables provide a description of the HX Outdoor type connectors and LEDs. Connector Description Antenna N-Type female 50Ω duplexed connector for RF antenna F/O Uplink and Downlink SC/APC fiber-optic connector for either SM or MM fibers AC or DC PWR Local Power (AC) or Remote DC Power feed options: 90-264 V AC or 36-75V DC Max Power Consumption: 350W RS-232 Local craft connector Table 1-5. Connector Descriptions Name Description Color Status Power Device is powered GREEN Steady On Power not supplied to the unit GREEN Off Table 1-6: HX Outdoor PWR LED MobileAccessHX Installation and Configuration Guide System Installation HX Indoor Installation System Installation This chapter describes the installation procedure for the MobileAccessHX Indoor and Outdoor Remote Units. The installation procedure differs according to the type of enclosure. 2.1 HX Indoor Installation 2.1.1 Unpacking and Inspection Unpack and inspect the cartons according to the following procedure 1. Open the shipping carton and carefully unpack each unit from the protective packing material. 2. Verify that all the parts have been received: Description Qty HX Indoor Cabinet For AC power models - AC power cord Item Note: Image shown here is for example only For rack mount installations– 19” rack brackets (and cabinet assembly screws) 2 (R/L) For wall mount installations – wall bracket (and cabinet assembly screws). 2 (R/L) 3. Check for signs of external damage. If there is any damage, call your MobileAccess service representative. MobileAccessHX Installation and Configuration Guide 10 System Installation 2.1.2 HX Indoor Installation Grounding Grounding for: • • AC Cabinets - Mandatory DC Cabinets - Recommended Connect the grounding cable to the HX cabinet via the grounding lug located on the rear of the unit. The cable can be connected to the grounding source after the unit is mounted either in the communication rack or on the wall. Grounding lug Figure 2-1: Rear View of HX Indoor Unit 2.1.3 Mounting The HX indoor model installation requires two people and can be installed either on the wall or in a 19” communication rack. Each type of installation requires a different pair of brackets (both types supplied). General Installation Instructions ATTENTON ! The Indoor type HX Remote Units should be installed in a communication room that provides access only to authorized personnel. The units are maintenance free. In the event of failure, only authorized personnel should handle the units. 2.1.3.1 • Environmental Data - Maximum ambient operating temperature: 50° C • Maximum ambient temperature in a rack: 45° C Wallmount Installation The EXAMPLE is for CONCRETE walls (requires anchors McMaster-Carr catalogue number 92403A200, or equivalent). To mount HX on wall 1. Assemble the WALL MOUNT BRACKETS (2) to the REAR PANEL of the HX cabinet using the supplied screws (4 for each bracket). 2. Using the bracket holes as a guide, drill four holes (2 for each bracket) for concrete anchors. MobileAccessHX Installation and Configuration Guide 11 System Installation HX Indoor Installation 3. Insert the anchors in the wall and hang the HX cabinet. Holes for hanging HX unit on anchors Figure 2-2. HX Indoor Unit with Assembled Wallmount Brackets 2.1.3.2 Rack Mount Installation Rack Installation General Safety Instructions Review the following guidelines to help ensure your safety and protect the equipment from damage during the installation. • Only trained and qualified personnel should be allowed to install or replace this equipment. • Verify that ambient temperature of the environment does not exceed 50°C (122°F) • To maintain a low center of gravity, ensure that heavier equipment is installed near the bottom of the rack and load the rack from the bottom to the top. • Ensure that adequate airflow and ventilation within the rack and around the installed components so that the safety of the equipment is not compromised. It is recommended to allow for at least about 2 cm of airspace between devices in the rack. NOTE: The cabinet requires a clearance of 10 cm above the unit. If a heating source is installed beneath the HC cabinet, a buffer must be placed between the cabinet and the surface. MobileAccessHX Installation and Configuration Guide 12 System Installation HX Indoor Installation To install HX unit in rack NOTE: Plan the location of the unit in the rack. If there is a heat emmitting device located below the unit, place a heat absorbent buffer between the HX cabinet and heat emitting device. 1. Assemble the Rack Mount Brackets to the Side Panels of the HX cabinet using the supplied screws. 2. Mount in the 19” rack and secure with the supplied screws. 10 cm Clearance above HX Cabinet Rack Brackets Location of Heat Absorbing Buffer (Not Supplied) Figure 2-3. Example of Similar Indoor Cabinet with Rack Brackets and Heat Buffer 3. If there is a heat emitting device located below the unit, place a Heat Absorbing Buffer (Not supplied) beneath the HX cabinet. MobileAccessHX Installation and Configuration Guide 13 System Installation HX Indoor Installation 2.1.4 Connections 2.1.4.1 HX Indoor SISO Connections The HX main connections consist of the following: • • • RF antenna Fiber Optic connection Power connections Connect the HX Indoor unit as follows 1. Connect broadband ANTENNA coax to HX cabinet DUPLEXED ANTENNA port (external): 2. OPEN cabinet door. Fiber optic port on HX RHU module Duplexed RF antenna port Location of DC power AC power Figure 2-4. HX Indoor Connections - SISO 3. Connect F/O cables to RHU optic port (internal) – 1 F/O connection for SISO models and 2 F/O connections for MIMO models. NOTE: Keep in mind the rules for handling and connecting F/O cables. The F/O cables will be connected to the associated BU in the communication room at a later phase. • • • Install splice box near Remote Cabinet. Connect fiber optic cable to splice box and the SC/APC pigtails to the HX RHU module. Downlink: Connect the fiber optic cable pigtails from splice box, which comes from the BU port, to the corresponding RU port. Route the optic fibers so they will fit through the top opening in the door. MobileAccessHX Installation and Configuration Guide 14 System Installation • HX Indoor Installation Uplink: Connect the fiber optic cable pigtails from splice box, which comes from the RU, to the uplink port that connects to the BU. Route the optic fibers so they will fit through the top opening in the door. Note: The internal power connections and other connections should already be connected. 4. Connect AC (cable supplied) or DC power according to your MODEL. (Unit should power-ON). Important! For DC models, see Power Requirements for DC Inputs (in Preface MaterialSafety Instructions). 5. Verify that the RHU LEDs are GREEN: • PWR and Link: Steady Green • COMM: Blinking Green If the LEDs are not as described above, refer to HX Unit Interfaces for troubleshooting. 6. Route the fiber optic cables toward the TOP of the cabinet and the power cable towards the bottom. Routed fiber optic cable Route power cable from under Figure 2-5. Closed HX Cabinet with Routed Cables 7. Connect the grounding cable (previously connected to unit – see section 2.1.2) to the grounding source. 8. Close the cabinet door, routing the corresponding cables through the top and bottom openings and lock the door. MobileAccessHX Installation and Configuration Guide 15 System Installation 2.1.4.2 HX Indoor Installation HX Indoor MIMO Connections Connect the HX Indoor unit as follows 1. Connect broadband ANTENNA coax to HX cabinet MIMO1 and MIMO2 DUPLEXED ANTENNA ports (external): 2. OPEN cabinet door. RHU Fiber Optic ports MIMO1 and MIMO2 Antenna ports RHU LEDs for MIMO2 services Quad-band RHU LEDs Power* Figure 2-6. HX Indoor MIMO F/O, RF and Power Connection and LEDs 3. Connect SC/APC cables to each of the RHUs optic ports. 4. Connect AC (cable supplied) or DC power according to your MODEL. (Unit should power-ON). *The power is either AC or DC (model dependant), whereas: Power Model Max. Consumption Local Power (AC): 500W Connector Image 90-264V AC Remote DC: 36-75V DC 500W 5. Verify that the RHU LEDs are GREEN: • PWR and Link: Steady Green • COMM: Blinking Green 6. Route F/O cables through TOP of the cabinet and Power cable towards the bottom. MobileAccessHX Installation and Configuration Guide 16 System Installation HX Outdoor Installation Routed Fiber Optic cables from RHU optic ports Power cable routed from underside Figure 2-7. Closed HX MIMO Cabinet with Routed F/O and Power Cables 2.2 HX Outdoor Installation IMPORTANT The HX Outdoor unit includes non-standard fiber optic, power and communication connectors that require one of the following options: 1) Ordering the appropriate cables from MobileAccess OR 2) Referring to the connectors descriptions’ and manufacturers’ P/N for the proper wiring information-see Appendix C. 2.2.1 Unpacking and Inspection Unpack and inspect the cartons according to the following procedure 1. Open the shipping carton and carefully unpack each unit from the protective packing material. 2. Verify that all the items have been received. 3. Check for signs of external damage. If there is any damage, call your MobileAccess service representative. MobileAccessHX Installation and Configuration Guide 17 System Installation HX Outdoor Installation Description Qty HX Outdoor Enclosure Item Bracket Screws, bolts and nuts For pole mount installations MobileAccessHX Installation and Configuration Guide 18 System Installation HX Outdoor Installation 2.2.2 Mounting 2.2.2.1 Wall Mount Installation Note: The brackets required for mounting the unit on the wall are integrated in to the rear panel – no required assembly. 1. Select the wall mount location according to the following criteria: • • • General surroundings Shielded, ventilated, and easy-to-reach area (for maintenance and on-site inspection) Proximity to the antenna in order to minimize cable loss Figure 2-8: HX Unit Dimensions 2. MEASURE AND MARK the location of the mounting holes (outer side) on the wall according to the Wall Mount Brackets assembled on the unit (see Figure 2-9). MobileAccessHX Installation and Configuration Guide 19 System Installation HX Outdoor Installation 3. DRILL x4 holes (x2 for each bracket) and insert and secure the appropriate BOLTS - allowing them to protrude enough to hang the unit). Drill holes in wall and insert bolts according to these locations Figure 2-9: Bracket Holes for Wall Mount 4. Hang the HX unit on the bolts inserted in the wall – requires TWO people. 5. After hanging the unit, REACH UNDER and BEHIND the bracket and further TIGHTEN the WALL BOLTS using the appropriate wrench. After hanging the unit, tighten bolts from behind bracket (between bracket and unit). Figure 2-10: HX Unit Mounted on Wall MobileAccessHX Installation and Configuration Guide 20 System Installation 2.2.2.2 HX Outdoor Installation Pole Mount Installation The pole mount installation requires using the supplied pole mount brackets (see section 2.2.1). Overview • • • • Position TOP bracket pair on pole. Hang the unit on the top bracket and secured tightly. Position the BOTTOM bracket pair on the pole according to the unit. Secure tightly. Top pole bracket set Pre-assembled HX bracket Bottom pole bracket set Pre-assembled HX bracket Figure 2-11: Pole Mounted HX – Side View Figure 2-12: Pole Mounted HX – Rear View Pole Mount Installation Procedure 1. Select the appropriate location according to the following criteria: • • Accessibility Antenna location and distance 2. Position and hold an OUTER TOP bracket in on the pole. MobileAccessHX Installation and Configuration Guide 21 System Installation HX Outdoor Installation 3. Insert supplied washer and bolt in the bracket and momentarily support it with your hands. Washer Bolt head Pole Bracket Pole Figure 2-13: Outer Pole Bracket with Inserted Bolts 4. Fit the inner brackets through the bolts. Outer Bracket TOP bracket pair Inner Bracket Figure 2-14: Brackets on pole – Top View Figure 2-15: Brackets on pole – Side View 5. Raise the HX Unit, either manually using two people or a crane lifting from the top ring (optional), and fit the two top holes onto the top bracket bolts. MobileAccessHX Installation and Configuration Guide 22 System Installation HX Outdoor Installation 6. Reach under and secure as shown below. Ring for CRANE (optional) Reach under and Tighten Insert TOP bracket bolts Figure 2-16: Bracket Holes through which the Pole Bracket Bolts are Inserted Figure 2-17: Assembled Pole Brackets and HX Unit 7. Position the BOTTOM brackets pair on the pole, align with the bottom holes on the HX unit and secure tightly. Pre-assembled HX Bracket Tighten nuts from behind Nut Figure 2-18: Top view of Pole Mounted HX Unit MobileAccessHX Installation and Configuration Guide 23 System Installation 2.2.3 HX Outdoor Installation Connections The connections are performed from the underside of the HX unit after it has been mounted. PWR RF Antenna LED F/O UL F/O DL Power Input (model dependent) Figure 2-19: HX Underside Interfaces 1. Perform the following connections using the appropriate cables: Note: If not ordered from MobileAccess, refer to section Appendix C for connectors’ information required for wiring. • • • RF Antenna Uplink and Downlink fiber optic connections Power – AC or DC power feed options: Local Power (AC): 90-264 V AC Remote DC Power: 36-75V DC. For DC Power Source installation: For ‘+’ Source: Connect ‘+’ link with ‘+’ source Connect ‘-‘ link with ground For ‘-‘ Source: Connect ‘+’ link with ground Connect ‘-‘ link with ‘-‘ source 2. Verify that Power LED Shows GREEN MobileAccessHX Installation and Configuration Guide 24 Commissioning MA Head-End Initial Controller Setup Commissioning MA Head-End This section is relevant for installations in which an MA1000/2000 architecture is NOT already installed at the site. This section provides a description of how to configure the head-end units required for HX operation which include the SC-450 Controller, RIU and Base Unit. NOTE: This section does NOT describe the physical installation of the head-end units. The physical installation is described in the corresponding Quick Installation Sheets or User Manuals. 3.1 Initial Controller Setup NOTE: The available tabs and options may vary depending on the access level used to open your session. This section provides the details on the basic setup and configuration of the SC-450 management interface. It is to be completed after the physical installation of the controller and connections to the relevant devices has been completed. 3.1.1 Open a Session to the Controller 1. Verify you computer is configured for a DHCP server: NOTE: The procedure may differ depending on your specific Windows OS. a. In the Local Area Connections choose Properties. b. Select Internet Protocol (TCP/IP) Connection, choose Properties and define for DHCP and automatic DNS server address acquisition as shown in following figure. Click OK. 2. Connect the PC directly to the SC-450 LOCAL port via the supplied cross-cable cable as illustrated below. Warning!!! Do NOT connect the SC-450 LOCAL port to a network as its DHCP server can disrupt LAN IP addressing. Supplied Ethernet cross-cable Figure 3-1. Connect PC to the SC-450 Local Port MobileAccessHX Installation and Configuration Guide 25 Commissioning MA Head-End Initial Controller Setup 3. Open a Web browser and enter the SC-450 default address: 10.1.1.1. Figure 3-2:SC-450 Default Address The SC-450 has been optimized for use on IE 6.0 and Firefox 3.0 or higher. For proper display on IE 8.0 use compatibility mode by selecting Tools -> Compatibility View Options and Add the SC-450 website 10.1.1.1. The Login dialog appears. Figure 3-3: SC-450 Login Dialog 4. To open a session with configuration privileges, enter: a. User Name: ‘engineer’ b. Default Password: ‘eng’ MobileAccessHX Installation and Configuration Guide 26 Commissioning MA Head-End 3.1.2 Initial Controller Setup IP Address Configuration Set the SC-450 LAN port for remote control via static or dynamic IP address.. NOTE: Local setup and troubleshooting is performed via the SC-450 LOCAL port. In addition, the Local port can be assigned a static IP address and connected to the customer LAN for remote access capability. To Configure SC-450 for Remote or Local Management 1. Access the GUI interface of the SC-450. 2. Select the Management tab and then click IP Settings on the side bar menu. LOCAL Port Configuration Area LAN Port Configuration Area Figure 3-4: SC-450 Management Tab 3. To change the LAN Port network settings, click the Modify button in the LAN Port Configuration Area. The following dialog appears. Figure 3-5: Modify IP Settings LAN Port Dialog MobileAccessHX Installation and Configuration Guide 27 Commissioning MA Head-End To Define… Initial Controller Setup Do This… Set DHCP as None. Static IP Address Enter the IP Address, Subnet and Gateway. Click OK. Dynamic IP Address Set DHCP as Client and click OK. 4. To change the LOCAL Port network settings, click the Modify button in the LOCAL Port Configuration Area. The following dialog appears. The LOCAL Port configuration settings are displayed on the SC-450 LCD. To Define… Static IP Address Do This… Set DHCP as None. Enter the IP Address and Subnet. Click OK. Set DHCP as Server and click OK. DHCP Server WARNING!!! When using this setting, connect ONLY directly to the PC – NOT to a network. MobileAccessHX Installation and Configuration Guide 28 Commissioning MA Head-End 3.2 Configure Controller Settings Configure Controller Settings In the Network Topology, double-click on the controller item. The controller General tab is displayed, where the Controller Mode is displayed as shown below. Figure 3-6: SC-450 General Tab Configure as follows: 1. In the General tab: • Assign the controller a recognizable Name indicating its location or other. • Verify that the correct Time and Date are set for the controller since events for devices under this controller will be received with the set time and date. • Set the Controller Type according to your system. • Click the Base Line button. This sets all of the MobileAccess devices currently displayed in the Network Topology pane as a reference and will continue displaying them (in gray) even if communication is lost with a device. 3.3 Device Configuration and Preparation This procedure consists of two phases: configuration and preparation phase and adjustment procedure. NOTE: The available tabs and options in the SC-450 Web GUI may vary depending on the access level used to open your session. Phase I 1. Log-in to the SC-450. Refer to section 3.1.1 for details. 2. Verify that the Base Unit, RIU and HX units are displayed in the Network Topology tree. NOTE: HX units are hosted by the BU and are detected every time the BU is powered-up or reset from the Web GUI application. Verify that all the elements are displayed in the Network Topology pane under their corresponding hosts, and are colored green, red, or yellow. Any of these colors are acceptable before the adjustment procedure has been performed (following sections). MobileAccessHX Installation and Configuration Guide 29 Commissioning MA Head-End Device Configuration and Preparation Controller Element BTSC Modules OPTM (BU) Modules Figure 3-7: Example of Network Topology 3. Verify that the BU is set to operate with RIU: • Click on the BU item in the Network Topology Tree Select RF Parameters Tab from the Work Area Interface Type to MA RIU • Optional: Assign the BU an identifiable name by Modifying the Name parameter in the Module Info tab 4. Using a Fiber Optic Tester, verify that the UL Optical Link Level of the fiber connected to the BU is >0 • Set the Fiber Optic Tester to a wavelength of 1310nm • Unplug the UL fiber connection from the BU and test to make sure it is at a level >0 • If the level is not >0, clean the fiber and retest 5. Set up CW signal to be connected to the signal conditioner (BTSC/BDAC). The 700 MHz LTE conditioner does not need an external CW signal (See Section 3.4.2). • BTSC acceptable input power range = +10 to +36dBm • BDAC acceptable input power range = -16 to +10 dBm • Acceptable frequency range depends upon the RF service 6. Adjust the signal conditioner (BTSC/BDAC) with the CW signal. The 700 MHz LTE conditioner does not need an external CW signal. (See Section 3.4.2). • Connect the CW signal to the BTSC/BDAC DL Port or Duplex port located on the rear of the RIU associated with the slot that the signal conditioner (BTSC/BDAC) is inserted into • Click on the conditioner in the Network Topology Tree Select RF Parameters Tab from the Work Area Adjust Max Input Power by clicking on the Adjust button in the DL Power section Select Use Current Input Power • After a few moments, verify that the Target Max Input Power and the Current Input Power are equivalent 7. Repeat Step 6 for each signal conditioner 8. Perform a Quality and Integrity Check of the installed system as per the RF Design and Statement of Work. Contact a MobileAccess Project Manager for more instructions. MobileAccessHX Installation and Configuration Guide 30 Commissioning MA Head-End RIU Configuration Phase II These Phase II steps should only be performed after completing Phase I of the commissioning process. NOTE: Please consult a MobileAccess certified installer on the details of these steps or access the MobileAccess Partner Portal for more information. 1. Perform an Emulated Adjustment 2. Perform UL Noise Mitigation 3.4 RIU Configuration There are two types of RIU configuration procedures: • • 3.4.1 Configuration for all BTSC modules except for LTE 700 Configuration for BTSC 700 module Configuration for all BTSCs (other than LTE 700) Perform this procedure for each RIU module (BTSC/BDAC): 1. Double-click on the BTSC item in the Network Topology. The BTSC configuration dialog appears. Figure 3-8: BTSC Module Info Tab 2. Assign the BTSC an identifiable name (i.e. operator name), by clicking the Modify button and typing the name. 3. Click on the RF Parameters tab. MobileAccessHX Installation and Configuration Guide 31 Commissioning MA Head-End RIU Configuration Figure 3-9: BTSC RF Parameters Tab 4. Verify that Service Control is ON. 5. Set DL AGC Control to ON. (OFF – Disables automatic gain control.) 6. (Do NOT modify the UL Atten. Value – this is factory set and should NOT be modified unless unique conditions exist.) 3.4.2 BTSC LTE 700 MHz To Configure and Control the MobileAccess BTSC LTE 700 MHz 1. Double-click on the LTE BTSC item in the Network Topology. The LTE BTSC configuration dialog appears with the Module Info tab displayed by default. Figure 3-10: BTSC LTE 700NHz Module Info Tab This tab provides general information such as software and hardware versions, type and serial number of the LTE BTSC. 2. Assign the BTSC LTE 700 MHz an identifiable name (i.e. operator name), by clicking the Modify button and typing the name. 3. Click on the RF Parameters tab, the following tab is displayed. This tab shows information on the RF parameters, and provides service and RF signal control options. MobileAccessHX Installation and Configuration Guide 32 Commissioning MA Head-End RIU Configuration Figure 3-11: BTSC LTE 700NHz RF Parameters Tab 4. To control the service supported by this BTSC choose an option in the Service Control field: • ON – Enables Service • OFF – Disables Service 5. Under DL Power section of the tab, click Adjust and select the required value (dBm) and click OK. Figure 3-12: DL Power Adjust Dialog 6. The DL power gain may be set automatically (AGC) or manually (DCA – Digital Control Attenuation). To control the DL gain control, set the DL AGC Status: • ON – Enables automatic gain control to compensate for input power variations. When enabled, gain control is performed automatically. MobileAccessHX Installation and Configuration Guide 33 Commissioning MA Head-End RIU Configuration • OFF – Disables automatic gain control and enables DCA to be set manually (DL DCA Manual Override Value). 7. UL Atten. Value – Controls attenuation on the uplink. This value is set during manufacturing and should be modified only under special circumstances. 8. Sup. Parameters tab – Relevant only for the initial adjustment procedure of the complete system (See LTE addendum document: UMA_MA1000 MA2000_700MHz LTE AO). Otherwise disregard. This option provides an internal signal generation source that can be used during the adjustment procedure instead of connecting an external signal generator. Figure 3-13: BTSC LTE 700NHz Sup. Parameters Tab • ON – Internal signal source activated. • OFF – Internal signal source disabled. MobileAccessHX Installation and Configuration Guide 34 Commissioning MA Head-End 3.5 Base Unit Configuration Dialog Base Unit Configuration Dialog The configuration dialog consists of two tabs: Module Info and RF parameters. The main provided functions are: • • In the Module Info tab - Viewing basic information on the unit and assigning the unit an identifiable name. In the RF Parameters tab - Setting gain control, resetting the Base Unit (required when an RHU is added) and monitoring the downlink signal. To Configure and Control the Base Unit: 1. Double-click on the Base Unit item in the Network Topology. The Base Unit configuration dialog appears. Figure 3-14: Base Unit Module Info Tab 2. In the Module Info tab click the Modify button and assign the BU an identifiable name that indicates the technology to which it interfaces. 3. Click the RF Parameters tab. MobileAccessHX Installation and Configuration Guide 35 Commissioning MA Head-End Base Unit Configuration Dialog Figure 3-15: Base Unit RF Parameters Tab Set the following parameters: • Interface Type – RF Source interface type (i.e. MA RIU, Other) • AGC Status – Sets DL AGC mode: ON – Automatic gain control to compensate for input power variations. When enabled, gain control is performed automatically. OFF - DCA can be set manually (DL DCA Manual Override Value). • UL Atten. Value – Controls attenuation on the uplink. This value is set during manufacturing and should be modified only under special circumstances. MobileAccessHX Installation and Configuration Guide 36 Provisioning the MobileAccessHX Accessing HX Management Options Provisioning the MobileAccessHX Once the required physical connections have been completed, the HX unit is automatically detected (auto-discover) by the SC-450 and can be remotely monitored and managed. The MobileAccessHX Remote Unit is centrally managed via the MobileAccess SC-450 Controller. Note that MobileAccessHX is not connected directly to the controller. It is connected to the Base Unit (that is connected to the controller). Thus, the controller monitors views and manages the HX via the Base Unit to which the HX is connected. Note: The provisioning procedure is similar for both Indoor and Outdoor HX units and consists of two simple steps: assigning the unit name (Module Info tab) and clicking the Adjust button (Adjustment tab). Additional configuration options are available as well. Each HX unit can be managed via several dedicated panes that are accessed by clicking the relevant HX item in the SC-450 Topology Tree. 4.1 Accessing HX Management Options To access the MobileAccessHX management options In the Network Topology tree, expand the relevant Controller item, expand the relevant Base Unit (to which the HX is connected) and click on the HX. The HX alarms and management tabs appear. Controller Host Base Unit HX item HX Alarm status Four management tabs Figure 4-1: Example of HX Unit Module Info Tab (Shows Indoor) The HX Cabinet Alarms are continuously displayed (to the left of the tabs). The monitoring and configuration options are distributed over four tabs: • Module Info - device version and identification definitions MobileAccessHX Installation and Configuration Guide 37 Provisioning the MobileAccessHX • • • 4.2 Basic Setup Procedure RF Parameters – service control options. RF Adjustment – provides the adjustment options. Service Alarms – used for masking redundant alarms Basic Setup Procedure To perform basic setup 1. Verify that the alarms show green in the following tabs: • HX Cabinet Alarms – displays system level alarms Figure 4-2: Example of HX Alarms The following table provides a description of the device alarms shown above. Alarm Description HX General Alarm N/A Optical Link Alarm Low optical level from BU (link level < 56) Fans Alarm* Faulty fans Service 1/2/3/4 Summary of all port x / PA x monitored parameters displayed in the Service Alarms sub-tab Overall status Calculated according to its active alarms corresponds to highest alarm level detected. – *The Fans alarm is only relevant for the HX Indoor unit. The alarm can be masked for HX Outdoor units (see following Step 2 of this section). Table 4-1. HX Alarms Description MobileAccessHX Installation and Configuration Guide 38 Provisioning the MobileAccessHX • Basic Setup Procedure Service Alarms – displays specific alarms for each supported service. Table 4-2. HX Service Alarms Description Alarm Description Service Off Service disabled by the User Adjustment Adjustment for target DL Output Power VSWR Alarm Antenna disconnected (VSWR > 5:1) DL Output Power High DL Output Power > “Target Adjustment value” + 2dB DL Output Power Low DL Output Power < “Target Adjustment value” 1 15dB Over Temperature Ambient temperature inside the HX unit >65°C MobileAccessHX Installation and Configuration Guide 39 Provisioning the MobileAccessHX Basic Setup Procedure 2. Mask irrelevant alarm conditions, in both tabs via the Modify button, to avoid having them reflected overall status of the HX unit (displayed in the HX Alarms area). For Example In the example below, the HX Cabinet Alarms dialog shows the alarm response if the Service 2 DL Output Power Low alarm is NOT masked (enabled). In that case the Service 2 and Overall Status will be RED indicating a fault. RED - Unmasked alarm reflects on corresponding Service alarm and Overall Status Unmasked alarm If the Service 1 alarm is MASKED (Disabled), then the LED for the alarm will be RED; but, the corresponding Service alarm in HX Cabinet Alarms area will be GREEN – showing NO Fault. Note: The Overall Status alarm will only show green if all of the generated alarms are masked (or if all alarms are green). GREEN - Masked DL Output Power Low alarm (for Service 1) alarm does not reflect on corresponding Service alarm in HX Cabinet Alarms area. Masked alarm In the figure above the alarm condition for (Service 1) “DL Output Power Low” actually exists, while the masking prevents this condition from affecting the overall status of the service and therefore the Service 1 led in HX Cabinet Alarms area is green. MobileAccessHX Installation and Configuration Guide 40 Provisioning the MobileAccessHX Basic Setup Procedure 3. Assign the unit a recognizable name (i.e. corresponding to its location): In the Module Info tab, click the Modify button, enter the required text and click OK. The assigned name will be displayed. User assigned name Figure 4-3: HX Module Info Tab 4. Click the RF Paramaters tab. Services enabled Figure 4-4: HX RF Parameters Tab 5. In the DL Adjustment tab: Verify the following: • • All required services (e.g. Cell 800, 700 LTE, etc.) are enabled (Default = On) UL Limiter is enabled (Default = On) NOTE: DL Factory DCA Restore – DO NOT click Restore button unless DL adjustment fails. MobileAccessHX Installation and Configuration Guide 41 Provisioning the MobileAccessHX Basic Setup Procedure 6. Verify that the System UL Gain is set to default configuration (i.e. Normal). See following table for Description of System UL Gain values. Field Value Case Scenario UL Gain (dB) UL Limiter Threshold (dBm) NF Type (dB) Low -30 13 Set in cases where mobile stations are very near to the HX antenna (e.g. in cases where HX unit antenna port is split to multiple lower power antennas to cover standard office building) Normal 11 -40 10 Default – for standard HX installations High 21 -50 Set in cases where mobile stations are located far from the HX antenna (e.g. in a parking lot, where the HX unit is mounted high on a pole). * Max. NF = Typical NF + 4dB 7. In the DL Adjustment tab, perform DL adjustment manually to complete the commissioning procedure. • Set the Target Max Pwr (Target Pout) value according to site planning requirements. Default Target Max Power value is the maximum value per each band (e.g. 33 dBm for 700LTE band). • • • DL Output Power can be adjusted to a lower level (up to 10dB lower) as required. Click the Adjust button. Confirm that the adjustment procedure is successful (Adjust Result shows “Success”) and verify actual readings of Adj. Date and DL Output Pwr . If adjustment procedure fails, refer to the RF Parameters tab, click the Restore button and perform adjustment again. Click to select Target Max Power Click to perform RF adjustment according to Target Max Power Verify successful results Adjustment Date and Actual DL Pwr reading Figure 4-5: HX DL Adjustment Tab THE HX SETUP PROCEDURE IS NOW COMPLETE MobileAccessHX Installation and Configuration Guide 42 Appendix A: System Specifications Supported Services Services Band Frequency Range Uplink Downlink CDMA / WCDMA** / TDMA / GSM CELL800 824-849 869-894 CDMA / WCDMA** / TDMA / GSM PCS1900 1850-1915 1930-1995 WCDMA** / HSPA AWS2100 1710-1755 2110-2155 LTE 700 MHz 698-716 776-787 728-757 GSM / GPRS / WCDMA / HSPA / LTE EGSM900 880-915 925-960 GSM / GPRS / WCDMA / HSPA / LTE* DCS1800 1710-1785 1805-1880 UMTS2100 1920-1980 2110-2170 WCDMA / HSPA / LTE* (*) WCDMA service is based on 3GPP standards, LTE service may be deployed in the future due to frequencies re-farming planned by the Carriers (**) WCDMA service is based on 3GPP2 CDMA2000 standards. MobileAccessHX Installation and Configuration Guide 43 Appendix A: System Specifications RF Parameters per Service MobileAccessHX RF Parameters MobileAccessHX RF Parameter LTE 700 MHz CELL TDMA / CDMA / WCDMA 800 MHz DL Max Output Power: 1 Carrier (Composite) UL DL UL PCS CDMA / WCDMA 1900 MHz DL UL AWS CDMA/ GSM / WCDMA 2100 MHz E-GSM DL UL 900 MHz DL UL DCS UMTS 1800 MHz 2100 MHz DL DL UL 33 33 33 33 29 32 33 2 Carriers 30 30 30 30 26 29 30 4 Carriers 27 27 27 27 23 26 27 8 Carriers 24 24 24 20 23 24 12 Carriers 22 22 22 17 21 22 24 Carriers 19 19 19 14 18 Mean Gain (dB)1 33 Pin (dBm) 1 11 33 11 33 11 33 11 29 11 32 11 33 UL 11 Input IP3 (dBm) AGC ON 16 16 16 16 16 16 16 Input IP3 (dBm) AGC OFF Typical -10 -10 -10 -10 -10 -10 -10 Max Intermod Distortion (dBm) NF (dB) Typical -13** -13* 10 -13* 10 -13* 10 VSWR Gain Flatness/Ripple (dB)2 -36* 10 -30* 10 -13* 10 10 1.5:1 +/-1.03 +/-1.5 +/-2.0 +/-1.5 +/-2.0 * WCDMA compiles with 3GPP TS 25.106 V5.0.0 (2002-03) table 9.4 spectrum emission mask. ** Out of band and spurious emissions compliant to FCC. Factory set mean gain BU-HX without RIU. May be field adjusted using controller system. Gain Flatness/Ripple is specified for the non-duplexed port of the system. Gain Flatness/Ripple at any block of the spectrum. MobileAccessHX Installation and Configuration Guide 44 Appendix A: System Specifications Optical Specifications Optical Output Power <3.0mW Max. Optical Budget 2 dB for fiber + 1 dB for connectors (assumed) = 3 dB total. 300 m Multimode Optical Loss per Mated-pair Connectors 0.5dB (max) Optical Connector SC/APC Single-mode: 9/125um Fiber Type Multi-mode: 50/125 um or 62.5/125um (Minimum qualifications with ANSI/TIA/EIA-568-B series, EN50173-1 or ISO/IEC 11801) Wavelength 1310±10nm Maximum Distance Between Base Unit and Remote Cabinet 2km for SMF 300m for MMF Physical Specifications – MobileAccessHX Remote Unit Indoor Remote Unit Ports Power Physical Dimensions Cooling Feature (1) SC/APC fiber-optic pair connector (1) N-Type female 50Ω connector for antenna (1) Power connector for 110/220VAC power feed or (4) Power connectors for up to (4) direct 48VDC power feeds (1) D-Type 9 pins RS-232 connector for local craft Local Power (AC) or Remote DC power feed options: 90-264 V AC or 36-75V DC Max Power Consumption: 350W Mounting: Wall or Rack Dimensions: 43cm x 38cm x 35cm (16.9” x 14.9” x 13.8”) [X,Y,Z] Weight: (3) Services SISO configuration: 30Kg (66 lb) (4) Services SISO configuration: 32Kg (71 lb) (2) SISO+(2) MIMO Services Configuration: 42Kg (92 lb) Active heat dissipation (Fan) MobileAccessHX Installation and Configuration Guide Outdoor Remote Unit (1) SC/APC fiber-optic pair connector (1) N-Type female 50Ω connector for antenna (1) Power connector for 110/220VAC power feed or (4) Power connectors for up to 4 direct 48VDC power feeds (1) D-Type 9 pins RS-232 connector for local craft Local Power (AC) or Remote DC Power feed options: 90-264 V AC or 36-75V DC Max Power Consumption: 350W Mounting: Wall or Poll Dimensions: 43cm x 63cm x 30cm (16.9” x 24.8” x 11.8”) [X,Y,Z] Weight (4 Services configuration): 52Kg (114 lb) Passive heat dissipation (Heat Sink) 45 Appendix A: System Specifications Environmental Specifications Indoor Remote Unit Outdoor Remote Unit Operating Temperature 0°C to +50°C (32°F to 122°F) -10°C to +50°C (14°F to 122°F) Storage Temperature -20°C to 85°C (-4°F to 185°F) -20°C to 85°C (-4°F to 185°F) Humidity IP65/NEMA Enclosure Protected from Elements and Waterproofing 10% to 95%, non-condensing IP65 * Lower temperature limit is applicable for cold-start. When turned-on at >-20°C the unit will continue to operate at lower temperatures. MobileAccessHX Installation and Configuration Guide 46 Appendix B: Ordering Information NOTE: The information listed below is updated up to the document publishing date. Refer to the MobileAccessHX datasheet for the most updated ordering information. MobileAccessHX Remote Units Indoor Units (SISO & MIMO) Service Supported Part Number Description HX-C85P19L70A17-AC-A MobileAccessHX Quad-service indoor CELL, PCS, AWS, and 700 MHz LTE solution supporting local AC power, SMF and MMF. HX-C85P19L70A17-DC-A MobileAccessHX Quad-service indoor CELL, PCS, AWS, and 700 MHz LTE solution supporting remote DC power, SMF and MMF. HX-C85P19L70MA17M-AC-A MobileAccessHX Quad-service indoor CELL, PCS, AWS MIMO, and 700 MHz LTE MIMO solution supporting local AC power, SMF and MMF. HX-C85P19L70MA17M-DC-A MobileAccessHX Quad-service indoor CELL, PCS, AWS MIMO, and 700 MHz LTE MIMO solution supporting remote DC power, SMF and MMF. HX-C85G91D18U21-AC-A MobileAccessHX Quad-service indoor CELL, GSM Partner, DCS, and UMTS solution supporting local AC power, SMF and MMF. HX-C85G91D18U21-DC-A MobileAccessHX Quad-service indoor CELL, GSM Partner, DCS, and UMTS solution supporting remote DC power, SMF and MMF. HX-G90D18U21-AC-A MobileAccessHX Tri-service indoor GSM, DCS, and UMTS solution supporting local AC power, SMF and MMF. HX-G90D18U21-DC-A MobileAccessHX Tri-service indoor GSM, DCS, and UMTS solution supporting remote DC power, SMF and MMF. HX-G90MD18U21M-AC-A MobileAccessHX Tri-service indoor GSM MIMO, DCS and UMTS MIMO solution supporting local AC power, SMF and MMF. HX-G90MD18 U21M-DC-A MobileAccessHX Tri-service indoor GSM MIMO, DCS and UMTS MIMO solution supporting remote DC power, SMF and MMF. HX-G90D18MU21M-AC-A MobileAccessHX Tri-service indoor GSM, DCS MIMO and UMTS MIMO solution supporting local AC power, SMF and MMF. HX-G90D18MU21M-DC-A MobileAccessHX Tri-service indoor GSM, DCS MIMO and UMTS MIMO solution supporting remote DC power, SMF and MMF. CELL/PCS/700LTE/AWS SISO Services CELL/PCS/700LTEMIMO/AWS-MIMO CELL/GSM/DCS/UMTS SISO Services GSM/DCS/UMTS SISO Services GSM/DCS/UMTS MIMO Services GSM/DCS/UMTS MIMO Services MobileAccessHX Installation and Configuration Guide 47 Appendix B: Ordering Information Service Supported Part Number Description HX-G90MD18MU21-AC-A MobileAccessHX Tri-service indoor GSM MIMO, DCS MIMO and UMTS solution supporting local AC power, SMF and MMF. HX-G90MD18MU21-DC-A MobileAccessHX Tri-service indoor GSM MIMO, DCS MIMO and UMTS solution supporting remote DC power, SMF and MMF. GSM/DCS/UMTS MIMO Services MobileAccessHX Remote Units Outdoor units (SISO services) Service Supported Part Number Description HX-C85P19L70A17-AC-B MobileAccessHX Quad-service outdoor CELL, PCS, AWS, and 700 MHz LTE solution supporting local AC power, SMF and MMF. HX-C85P19L70A17-DC-B MobileAccessHX Quad-service outdoor CELL, PCS, AWS, and 700 MHz LTE solution supporting remote DC power, SMF and MMF. HX-C85G91D18U21-AC-B MobileAccessHX Quad-service outdoor CELL, GSM Partner, DCS, and UMTS solution supporting local AC power, SMF and MMF. HX-C85G91D18U21-DC-B MobileAccessHX Quad-service outdoor CELL, GSM Partner, DCS, and UMTS solution supporting remote DC power, SMF and MMF. HX-G90D18U21-AC-B MobileAccessHX Tri-service outdoor GSM, DCS, and UMTS solution supporting local AC power, SMF and MMF. HX-G90D18U21-DC-B MobileAccessHX Tri-service outdoor GSM, DCS, and UMTS solution supporting remote DC power, SMF and MMF. CELL/PCS/700LTE/AWS SISO Services CELL/GSM/DCS/UMTS GSM/DCS/UMTS MobileAccessHX Installation and Configuration Guide 48 Appendix B: Ordering Information Accessories MobileAccessHX Expansion Kits Part Number Description AK-HX-A17-EXP MobileAccessHX accessory kit supporting AWS service expansion. Compatible with CELL/PCS and CELL/PCS/700LTE remote units. AK-HX-L70-EXP MobileAccessHX accessory kit supporting 700 MHz LTE service expansion. Compatible with CELL/PCS and CELL/PCS/AWS remote units. AK-HX-A17L70-EXP MobileAccessHX accessory kit supporting AWS and 700 MHz LTE services expansion. Compatible with CELL/PCS remote units. AK-HX-C85P19-EXP MobileAccessHX accessory kit supporting CELL and PCS services expansion. Compatible with AWS/700LTE remote units. AK-HX-C85L70-EXP MobileAccessHX accessory kit supporting CELL and 700 MHz LTE services expansion. Compatible with PCS/AWS remote units. AK-HX-U21-EXP MobileAccessHX accessory kit supporting UMTS service expansion. Compatible with GSM/DCS remote units. AK-HX-D18-EXP MobileAccessHX accessory kit supporting DCS service expansion. Compatible with GSM/UMTS remote units. AK-HX-G90-EXP MobileAccessHX accessory kit supporting GSM service expansion. Compatible with DCS/UMTS remote units. MobileAccessHX Installation and Configuration Guide 49 Appendix B: Ordering Information Ap p e n d ix C : P a r t Nu m b e r s fo r HX O u t d o o r We a t h e r R e s is t a n t C o n n e c t o r s The following table provides a description of the HX Outdoor RS-232, Power (AC or DC) and F/O connectors. Connector Manufacturer Name Manufacturer P/N Description AC Power KUKDONG KD3100A16S-5P-A02 CONN, 1-20UNEF, PLUG,3 PINS ,SOLDER FOR PANNEL,WATERPROOF DC Power KUKDONG KD3100A16S-01P-A02 CONN, 1-20UNEF, PLUG,8 PINS ,SOLDER FOR PANNEL,WATERPROOF UL and DL Fiber Optic connector MOLEX 1060592032 OPTICAL INDUSTRIAL ADAPTER,INDUSTRIAL SC TO SC SIMPLEX,APC KUKDONG KD3100A14SA10P-A02 CONN, 7/8-20UNEF,PLUG,10 PINS ,SOLDER FOR PANNEL,WATERPROOF RS232 Note: Used for local setup and maintenance by technical personnel Table 4-2: Non-Standard Connectors Descriptions MobileAccessHX Installation and Configuration Guide 50 Appendix B: Ordering Information Ap p e n d ix D: S it e P r e p a r a t io n This following installation rules are based on the assumption that site survey and installation planning (including power requirements) have been completed. Installation Requirements The infrastructure preparation consists of two main phases: A. Floor Planning: Planning the distribution of the antennas on each floor to provide the required coverage. B. Telecom Closet Planning: Planning the layout of the devices and cables in the telecom closet or shaft. Coaxial Cable Connections General Cable Installation Procedures Observe the general cable installation procedures that meet with the building codes in your area. The building code requires that all cabling be installed above ceiling level (where applicable). The length of cable from the risers to each antenna must be concealed above the ceiling. The cable must be properly supported and maintained straight using tie-wraps, cable trays and clamps or hangers every 10 feet (where practical above ceiling level). Where this is not practical, the following should be observed: • The minimum bending radius of the supplied ½” coax cable should be 7”. • Cable that is kinked or has a bending radius smaller than 7” must be replaced. • Cable runs that span less than two floors should be secured to suitably located mechanical structures. • The cables should be supported only from the building structure. MobileAccessHX Installation and Configuration Guide 51 Appendix B: Ordering Information Fiber Optic Rules • Either single mode or multimode fiber can be used with MobileAccess2000M products, while MobileAccess2000 products can only be used with single mode fiber. • Only Multimode fiber, 50/125 or 62.5/125um complying with ANSI/TIA/EIA-568-B series, EN50173-1 or ISO/IEC 11801 can be used. The fiber length can be up to 300 meters assuming the following qualifications: All fiber in a given length of fiber must be of the same core diameter. All Bulkhead adapters must be Single mode SC/APC (Green) adapters. All terminations cross connections or patches must be direct fusion splice or MobileAccess specified patch cords listed below. 900 microns pathcord for splicing, 2 Meters, 2xSC/APC Diamond p/n ENC/1045341 Beige boots, 62.5/125/900 MA# 500001057 Diamond p/n ENC/1045340 Black boots, 50/125/900 MA# 500001058 Zipcord patchcord, 4xSC/APC, 50/125/900/2000/4500 micron Diamond p/n ENC/1045342 Black/Brown boots, 1Meter MA# 50000105 Diamond p/n ENC/1045343 Black/Brown boots, 3 Meter MA# 500001060 Zipcord patchcord, 4xSC/APC, 62.5/125/900/2000/4500 micron Diamond p/n ENC/1045344 Beige/Brown boots, 1 Meter MA# 500001061 Diamond p/n ENC/1045345 Beige/Brown boots, 3 Meter MA# 500001062 • Use only 8-degree SC/APC connectors (green color). • Use only fusion splice for connecting two fibers. • Use minimum splicing/connectors to achieve minimum losses on the fibers (<0.5dB). • Use precaution while installing, bending, or connecting fiber optic cables. • Use an optical power meter and OTDR for checking the fiber optic cables. • Make sure the environment is clean while connecting/splicing fiber optic cables. • All fiber optic connections should be cleaned prior to attaching to termination points using a dry cleaning device (i.e. Cletop or equivalent). • Fiber connector protective caps should be installed on all non-terminated fibers and removed just before they are terminated. • Verify the Fiber Optic connections. You may use the Optical Test Procedure described at the end of this manual. • Pay special attention while connecting the SC/APC connectors - you must hear the “click” when the connection is made. RF Rules • Use coax RG223, 50ohm, male-to-male N-type for RF connections from the BUs to the BTS/RBS and to the RIU. MobileAccessHX Installation and Configuration Guide 52 Appendix B: Ordering Information • • • • • When using the MobileAccess system in an environment in which other indoor coverage systems are installed, it is recommended (where possible) that the antennas are placed at least two meters apart When bending coax cables, verify that the bending radius does not exceed the coax specifications. Use wideband antennas supporting a range of 800Mhz to 2500Mhz Use a VSWR meter (i.e. Site Master or equivalent) for checking coax cables, including the antennas. (<2). The VSWR must be measured prior to terminating the RUs in the remote communication rooms Terminate all unused RU and RIU ports with a 50 ohm load Power Consumption, Connections and Power Supplies Power Safety Instructions SAFETY WARNINGS • When installing or selecting the power supplies: • Be sure to disconnect all power sources before servicing. • SC-450 Controller lithium type battery should only be replaced by MobileAccess service personnel. Risk of exploding if battery is replaced by an incorrect type. Dispose of used batteries according to the instructions. • Calculate the required power according to the requirements of the specific installation and then determine the configuration of the power supplies. The required DC cables will then be determined by the selected PS configuration. • Use only UL approved power supplies • AC and DC power supply cables – only use the power cords supplied with the units • Battery replacement in units - only the SC-450 controller has batteries. These should be replaced (when necessary) only by MA Service Personnel. • Install external over-current protective devices for the system according to the requirements. Power Consumption of Units Table 4-3. MobileAccess Power Requirements Unit Type Voltage Input Power Consumption Maximum Current Consumption HX Remote Unit – Indoor Model Local: 90-264V AC or Remote: 36 to 75V DC 350W (max) HX Remote Unit – Outdoor Model Local: 90-264V AC or Remote: 36 to 75V DC 350W (max) Base Unit 20 to 48V DC 14W 0.7A SC-450 Controller 36 to 60 V DC 10W 0.2A MobileAccessHX Installation and Configuration Guide 53 Appendix B: Ordering Information Circuit Breakers Install fuse protections for the system according to the following criteria: • The following system elements require external fuse protection: RIUs, BUs, and SC450 Controllers. • Referring to Table 4-3, calculate the required fuse protection. • Example: a set of three elements consisting of a BU, RIU and SC-450 controller requires a 2A circuit breaker. Types of Power Supplies MobileAccess supplies various power supplies that can be installed in a rack or mounted on a wall, depending on your configuration. Installation Conventions Some of the basic installation conventions are listed below for the MA 2000 system: • Base Units – are usually concentrated in the same location, most often in the main communication room. • Remote Cabinet/Lite – usually placed in the communication shaft or closet of a corresponding floor so they can be easily located. Each cabinet (or MA2000-Lite) can typically cover a floor of up to 30,000 sq ft. • Fiber optic cable - bundled fibers are terminated into the Base Units in the main communication room. The fibers are then routed to each coverage locations where individual fibers terminate into splice boxes. The splice box couples the installed fiber into the remote units. Enough spare fibers should be installed to take into account future expansion of the system. For example, for three remote units, six fibers are required. However, to allow for future expansion, it is recommended to install additional optic fibers to be connected to additional RUs. Continued on the following page... MobileAccessHX Installation and Configuration Guide 54 Appendix B: Ordering Information The following figure illustrates fiber optic routing to Remote Cabinets. Figure 4-6. Illustration of Fiber Optic Routing • For remote power supply configuration - cable bundles are routed from the main communication room and individual wire pairs are terminated into the power feed of individual units. By providing power from a single distribution point, maintenance can be reduced and UPS backup can be easily provided. The maximum distance from the source to the termination spot is 1000 feet using 18 gauge wires. In many locations local codes do not require power to be run through conduit if 100 watts or less is used. Please consult the regulations in your local jurisdiction prior to deploying remote power. When power cables require distances greater than 1000 feet 14 or 16 gauge wire may be used. • On each floor - the antennas are connected to the Remote Cabinet or MA2000-Lite system using coax cables. MobileAccessHX Installation and Configuration Guide 55
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : Yes Author : Michal David Comments : Updated with Indoor MIMO product Company : to-the-Point Create Date : 2012:02:14 08:06:51+02:00 Modify Date : 2012:02:14 08:07:07+02:00 Source Modified : D:20120214060525 Tag Ad Hoc Review Cycle ID : 2075307393 Tag Author Email : michall@e-glue.com Tag Author Email Display Name : michal livne Tag Email Subject : to Mira... XMP Toolkit : Adobe XMP Core 4.2.1-c041 52.342996, 2008/05/07-20:48:00 Metadata Date : 2012:02:14 08:07:07+02:00 Creator Tool : Acrobat PDFMaker 9.0 for Word Document ID : uuid:225b0afe-b894-47d6-a8ce-30089c893945 Instance ID : uuid:7fddc869-dca3-459a-b9a6-625d7fdbf849 Subject : 9 Format : application/pdf Title : MbileAccessHX 2W UM Creator : Michal David Producer : Adobe PDF Library 9.0 Page Layout : OneColumn Page Count : 65EXIF Metadata provided by EXIF.tools