Frequency Range
AMPS/TDMA 800
LMR/iDEN 800
CDMA 800
SMR 900
GSM 900
Paging 900
GSM 1800
CDMA 1800
TDMA 1900
GSM 1900
CDMA 1900
Dual Band GSM 900/GSM 1800
Dual Band E-GSM 900/GSM 1800
Dual Band iDEN/LMR 800/PCS 1900
Daul Band SMR 900/PCS 1900
Dual Band Cellular 800/PCS 1900
Dual Band Paging 900/PCS 1900
Uplink
824-849
806-824
824-849
896-902
890-915
899-902
1710-1785
1710-1785
1850-1910
1850-1910
1850-1910
890-915/1710-1785
880-915/1710-1785
806-824/1850-1910
896-902/1850-1910
824-849/1850-1910
899-902/1850-1910
Downlink
869-894
851-869
869-894
935-941
935-960
928-941
1805-1880
1805-1880
1930-1990
1930-1990
1930-1990
935-960/1805-1880
925-960/1805-1880
851-869/1930-1990
935-941/1930-1990
869-894/1930-1990
928-941/1930-1990
Specifications
SC/APC Jumper
Local Power Supply
Remote Power supply -
Fully Redundant, Rackmount
Remote Power supply -
Fully Redundant, Rackmount
Remote Power supply -
Fully Redundant, Rackmount
Remote Power supply -
Wallmount
1m
3m
15m
24W 110/220V
150W 110/220V
500W 110/220V
1000W 110/220V
200W 110/220V
SCAPC-DJ-1
SPAPC-DJ-3
SCAPC-DJ-15
LPS-24-1A
RPS-150-R-48
RPS-500-R-48
RPS-1000-R-48
RPS-200-N-48
Order Code
BW
30 KHz
25 KHz
1.25MHz
25 KHz
200 KHz
200 KHz
1.25MHz
30 KHz
200 KHz
1.25MHz
Ordering Information
Product
Single Band Family
9A110 = AMPS/TDMA 800
9A112 = LMR/iDEN 800
9A130 = CDMA 800
9A212 = SMR 900
9A220 = GSM 900
9A240 = Paging 900
9A320 = GSM 1800
9A330 = CDMA 1800
9A410 = TDMA 1900
9A420 = GSM 1900
9A430 = CDMA 1900
Dual Band Family
9B320 = Dual Band GSM 900/GSM 1800
9B322 = Dual Band E-GSM 900/GSM1800
9B412 = Dual Band iDEN/LMR 800/PCS1900
9B422 = Dual Band SMR 900/PCS1900
9B430 = Dual Band Cellular 800/PCS1900
9B440 = Dual Band Paging 900/PCS1900
Reserved
Part
R4U = RHU 4 Antenna Ports
R1U = RHU 1 Antenna Port
B4U = Base Unit Four Ports
B8U = Base Unit Eight Ports
9XXXX - XXX - XX
Supported Services
Available Accessories
E-mail: sales@foxcomwireless.com
For Indoor use only.
All specifications are subject to change without prior notice.
The Litenna™, fiberoptic based distribution system, enables wireless service operators and
integrators to provide seamless coverage and enhanced cellular capacity for In-building applications.
Comprised of a Base Unit that connects up to eight Remote Hub Units (driving up to four antennas
each), the fiberoptic technology based system is modular and expandable to a wide variety of
structure sizes and configurations. The Litenna supports wireless voice and data applications,
offering a cost-effective and flexible solution for coverage enhancement.
Compliant with all existing wireless voice and data services: TDMA, CDMA, GSM
Supports GPRS, EDGE, CDPD and WAP technologies
Easily upgrad
e
able from single band to multi band and future services
-
3G
Single infrastructure for multiple services
/ multiple operators
Built-in alarms
and
monitor
ing
for all
links
Singlemode fiberoptic cables connect between the system units
Easy to design, install and maintain
Standard
Service
Mechanical Dimensions
Remote Hub Unit
19”
12”
1U
Base Unit
Base Unit Front Panel
Base Unit Back Panel
11
8”
Remote Hub Unit Front Panel
RF In RF OutAlarm
Optical In/Out
Optical In/Out
Antenna Ports
2”
* 1 antenna port Remote Hub Unit is also available.
Alarm Specifications
Base Unit Alarms
The Litenna™ Base Unit alarms are Dry Contacts and Open Collector types. The Dry Contacts opens when the alarm is active. The Open Collector will sink up to 30mA
under alarm condition. All alarms are connected to the Base Unit rear panel 25 pin D type connectors.
Alarm
Optical Link
Function
Indicates that the optical link between Base Unit and Remote Hub Unit are not functioning
LED Specifications
Base Unit LEDs
The Base Unit has three types of LEDs. One type indicates the power status. One type indicates that the lasers are functioning. One type indicates the status of link
operations between the Base Unit and the RHU-one LED for every RHU. All LEDs should be on when the unit is in operation.
LED Name
Channel 1..8
Lasers 1..4
Lasers 5..8
DC
LED Function
Indicates that both directions of the optical link, between Base Unit and Remote Hub Unit,
is functioning - one LED for every RHU link.
Indicates that laser circuitry for RHU 1-4 is functioning correctly.
Indicates that laser circuitry for RHU 5-8 is functioning correctly.
Indicates that the power is on.
Remote Hub Unit LEDs
On the Front Panel of the RHU there are two LEDs. Both LEDs should be on when the unit is in operation.
LED Name LED Function
Indicates that the Received Optical Power is functioning within specifications.
Indicates that the power is on.
Opt.
DC
Litenna Base Unit
Fiberoptic
Tx #1
Fiberoptic
Tx #8
Fiberoptic
Rx #1
Fiberoptic
Rx #8
Down Link
Up Link
RF Out
(Sector 1)
RF Out
(Sector 2 Opt.)
RF In
(Sector 1)
RF In
(Sector 2 Opt.)
Litenna™ Block Diagram
Litenna RHU #8
Fiberoptic
Rx #8
Fiberoptic
Tx #8
PA
LNA
Diplexer
RF
RF
Litenna RHU #1
Fiberoptic
Rx #1
Fiberoptic
Tx #1
PA
LNA
Diplexer
RF
RF
Absolute Maximum Rating
Specifications
Total Input RF Power - No Damage (dBm)
Power Supply (VDC)
Operating Temperature (ºC)1
Storage Temperature (ºC)
Base Unit Remote Hub Unit
1. For extended temperature range (-20 to 60ºC) contact Foxcom Wireless.
20 (Down Link)
60
0 to +50
-20 to +85
10 (Up Link)
60
0 to +50
-20 to +85
Fiber Optic Specifications
3.0
1.5
0.5 maximum
SC/APC
9/125 single mode
1310±10
Optical Specifications
Optical output power (mW)
Max. Optical budget (dB)
Optical loss per mated pair connectors (dB)
Optical Connector
Fiber type
Wavelength (nm)
(1) Distance increases with correlation to cable diameter.
For distance graeter than 2000m contact Foxcom Wireless.
General Specifications
Specifications Base Unit Remote Hub Unit
20-48VDC - DC input
or: 27-48VDC - fed through composite cable
18 W max. Singleband
24 W max. Dualband
11”W x 8”L x 2”H
N Type Female, Impedance 50
1.2
Power
Dimensions
RF Connector
Weight(Kg)
Other Specifications
Distance between BU and RHU (m)
DC power is supplied via composite cable @19AWG(1)
DC power is supplied via copper @ 12AWG(1)
MTBF (Hrs.) @ 25(ºC)
20-48VDC
10W max. Base Unit 8 ports
5W max. Base Unit 4 ports
19” x 1U Wallmount / Rackmount
N Type Female, Impedance 50
2.3
500 @ 48VDC
2000 @ 48VDC
366,855 for 1 Link (1 Bu+1 RHU)
Standards and Approvals
Europe
U.S.A
Canada
CE 0681 / ETS 300 609-4 (GSM 11.26), ETS 300 342-3, EN 60950 / EN 60825-2
FCC 47 CFT Part 22, 24, 90
IC
Alarm Specifications
Base Unit Alarms
The Litenna™ Base Unit alarms are Dry Contacts and Open Collector types. The Dry Contacts opens when the alarm is active. The Open Collector will sink up to 30mA
under alarm condition. All alarms are connected to the Base Unit rear panel 25 pin D type connectors.
Alarm
Optical Link
Function
Indicates that the optical link between Base Unit and Remote Hub Unit are not functioning
LED Specifications
Base Unit LEDs
The Base Unit has three types of LEDs. One type indicates the power status. One type indicates that the lasers are functioning. One type indicates the status of link
operations between the Base Unit and the RHU-one LED for every RHU. All LEDs should be on when the unit is in operation.
LED Name
Channel 1..8
Lasers 1..4
Lasers 5..8
DC
LED Function
Indicates that both directions of the optical link, between Base Unit and Remote Hub Unit,
is functioning - one LED for every RHU link.
Indicates that laser circuitry for RHU 1-4 is functioning correctly.
Indicates that laser circuitry for RHU 5-8 is functioning correctly.
Indicates that the power is on.
Remote Hub Unit LEDs
On the Front Panel of the RHU there are two LEDs. Both LEDs should be on when the unit is in operation.
LED Name LED Function
Indicates that the Received Optical Power is functioning within specifications.
Indicates that the power is on.
Opt.
DC
Litenna Base Unit
Fiberoptic
Tx #1
Fiberoptic
Tx #8
Fiberoptic
Rx #1
Fiberoptic
Rx #8
Down Link
Up Link
RF Out
(Sector 1)
RF Out
(Sector 2 Opt.)
RF In
(Sector 1)
RF In
(Sector 2 Opt.)
Litenna™ Block Diagram
Litenna RHU #8
Fiberoptic
Rx #8
Fiberoptic
Tx #8
PA
LNA
Diplexer
RF
RF
Litenna RHU #1
Fiberoptic
Rx #1
Fiberoptic
Tx #1
PA
LNA
Diplexer
RF
RF
Absolute Maximum Rating
Specifications
Total Input RF Power - No Damage (dBm)
Power Supply (VDC)
Operating Temperature (ºC)1
Storage Temperature (ºC)
Base Unit Remote Hub Unit
1. For extended temperature range (-20 to 60ºC) contact Foxcom Wireless.
20 (Down Link)
60
0 to +50
-20 to +85
10 (Up Link)
60
0 to +50
-20 to +85
Fiber Optic Specifications
3.0
1.5
0.5 maximum
SC/APC
9/125 single mode
1310±10
Optical Specifications
Optical output power (mW)
Max. Optical budget (dB)
Optical loss per mated pair connectors (dB)
Optical Connector
Fiber type
Wavelength (nm)
(1) Distance increases with correlation to cable diameter.
For distance graeter than 2000m contact Foxcom Wireless.
General Specifications
Specifications Base Unit Remote Hub Unit
20-48VDC - DC input
or: 27-48VDC - fed through composite cable
18 W max. Singleband
24 W max. Dualband
11”W x 8”L x 2”H
N Type Female, Impedance 50
1.2
Power
Dimensions
RF Connector
Weight(Kg)
Other Specifications
Distance between BU and RHU (m)
DC power is supplied via composite cable @19AWG(1)
DC power is supplied via copper @ 12AWG(1)
MTBF (Hrs.) @ 25(ºC)
20-48VDC
10W max. Base Unit 8 ports
5W max. Base Unit 4 ports
19” x 1U Wallmount / Rackmount
N Type Female, Impedance 50
2.3
500 @ 48VDC
2000 @ 48VDC
366,855 for 1 Link (1 Bu+1 RHU)
Standards and Approvals
Europe
U.S.A
Canada
CE 0681 / ETS 300 609-4 (GSM 11.26), ETS 300 342-3, EN 60950 / EN 60825-2
FCC 47 CFT Part 22, 24, 90
IC
frontback
In-Building RF Distribution System
©Sadna 5/2000
© Foxcom Wireless 2000.
Doc. No. 42-13-002-20-B
E-mail: salesna@foxcomwireless.com
Website: www.foxcomwireless.com
8150 Leesburg Pike
Suite 600
Vienna, Virginia 22182
Tel: 703-848-0200
Fax: 703-848-0280
Foxcom Wireless Inc.
Ofek One Center - Building B
Northern Industrial Zone
Lod, Israel 71293
Tel: +972-8-918-3888
Fax: +972-8-918-3844
Foxcom Wireless Ltd.
Frequency Range
AMPS/TDMA 800
LMR/iDEN 800
CDMA 800
SMR 900
GSM 900
Paging 900
GSM 1800
CDMA 1800
TDMA 1900
GSM 1900
CDMA 1900
Dual Band GSM 900/GSM 1800
Dual Band E-GSM 900/GSM 1800
Dual Band iDEN/LMR 800/PCS 1900
Daul Band SMR 900/PCS 1900
Dual Band Cellular 800/PCS 1900
Dual Band Paging 900/PCS 1900
Uplink
824-849
806-824
824-849
896-902
890-915
899-902
1710-1785
1710-1785
1850-1910
1850-1910
1850-1910
890-915/1710-1785
880-915/1710-1785
806-824/1850-1910
896-902/1850-1910
824-849/1850-1910
899-902/1850-1910
Downlink
869-894
851-869
869-894
935-941
935-960
928-941
1805-1880
1805-1880
1930-1990
1930-1990
1930-1990
935-960/1805-1880
925-960/1805-1880
851-869/1930-1990
935-941/1930-1990
869-894/1930-1990
928-941/1930-1990
Specifications
SC/APC Jumper
Local Power Supply
Remote Power supply -
Fully Redundant, Rackmount
Remote Power supply -
Fully Redundant, Rackmount
Remote Power supply -
Fully Redundant, Rackmount
Remote Power supply -
Wallmount
1m
3m
15m
24W 110/220V
150W 110/220V
500W 110/220V
1000W 110/220V
200W 110/220V
SCAPC-DJ-1
SPAPC-DJ-3
SCAPC-DJ-15
LPS-24-1A
RPS-150-R-48
RPS-500-R-48
RPS-1000-R-48
RPS-200-N-48
Order Code
BW
30 KHz
25 KHz
1.25MHz
25 KHz
200 KHz
200 KHz
1.25MHz
30 KHz
200 KHz
1.25MHz
Ordering Information
Product
Single Band Family
9A110 = AMPS/TDMA 800
9A112 = LMR/iDEN 800
9A130 = CDMA 800
9A212 = SMR 900
9A220 = GSM 900
9A240 = Paging 900
9A320 = GSM 1800
9A330 = CDMA 1800
9A410 = TDMA 1900
9A420 = GSM 1900
9A430 = CDMA 1900
Dual Band Family
9B320 = Dual Band GSM 900/GSM 1800
9B322 = Dual Band E-GSM 900/GSM1800
9B412 = Dual Band iDEN/LMR 800/PCS1900
9B422 = Dual Band SMR 900/PCS1900
9B430 = Dual Band Cellular 800/PCS1900
9B440 = Dual Band Paging 900/PCS1900
Reserved
Part
R4U = RHU 4 Antenna Ports
R1U = RHU 1 Antenna Port
B4U = Base Unit Four Ports
B8U = Base Unit Eight Ports
9XXXX - XXX - XX
Supported Services
Available Accessories
E-mail: sales@foxcomwireless.com
For Indoor use only.
All specifications are subject to change without prior notice.
The Litenna™, fiberoptic based distribution system, enables wireless service operators and
integrators to provide seamless coverage and enhanced cellular capacity for In-building applications.
Comprised of a Base Unit that connects up to eight Remote Hub Units (driving up to four antennas
each), the fiberoptic technology based system is modular and expandable to a wide variety of
structure sizes and configurations. The Litenna supports wireless voice and data applications,
offering a cost-effective and flexible solution for coverage enhancement.
Compliant with all existing wireless voice and data services: TDMA, CDMA, GSM
Supports GPRS, EDGE, CDPD and WAP technologies
Easily upgrad
e
able from single band to multi band and future services
-
3G
Single infrastructure for multiple services
/ multiple operators
Built-in alarms
and
monitor
ing
for all
links
Singlemode fiberoptic cables connect between the system units
Easy to design, install and maintain
Standard
Service
Mechanical Dimensions
Remote Hub Unit
19”
12”
1U
Base Unit
Base Unit Front Panel
Base Unit Back Panel
11
8”
Remote Hub Unit Front Panel
RF In RF OutAlarm
Optical In/Out
Optical In/Out
Antenna Ports
2”
* 1 antenna port Remote Hub Unit is also available.
µ ∂A
Dual Band - RF SpecificationsSingle Band - RF Specifications
* Specifications for PCS: CDMA / TDMA & GSM 1900.
** Specifications for Cellular: CDMA / TDMA 800.
800/1900 900/1900 900/1900 900/1800
Uplink
Link Specifications
800/1900
GSM
20
65
18
67
4.0
-2
-7
±2.5
±1.8
Paging
20
18
4.0
-2
-7
±2.0
±1.5
PCS*
20
71
18
72
4.0
-2
-7
±2.5
±1.8
SMR
20
71
18
72
4.0
-2
-7
±2.0
±1.5
PCS*
20
71
18
72
4.0
-2
-7
±2.5
±1.8
Cellular**
20
71
18
72
4.0
-2
-7
±2.0
±1.5
PCS*
20
71
18
72
4.0
-2
-7
±2.5
±1.8
iDEN/LMR
20
71
18
72
4.0
-2
-7
±2.0
±1.5
PCS*
20
71
18
72
4.0
-2
-7
±2.5
±1.8
GSM/EGSM
20
65
18
67
4.0
-2
-7
±2.0
±1.5
Four Antenna Ports RHU Spcifications
Max. NF (dB)
SFDR
One Antenna Port RHU Spcifications
Max. NF (dB)
SFDR
Common Spcifications
Nominal Gain (dB)
Min. Input IP3 (dBm)
Output 1dB Compression Point (dBm)
Gain Flatness (dB)
Over Band
Over Block
Uplink
Four Antenna Ports RHU Spcifications
Max. NF (dB)
SFDR
One Antenna Ports RHU Spcifications
Max. NF (dB)
SFDR
Common Spcifications
Nominal Gain (dB)
Min. Input IP3 (dBm)
Output 1dB Compression Point (dBm)
Gain Flatness (dB)
Over Band
Over Block
800
16
62
14
63
4.0
-2
-7
±2.0
±1.5
Link Specifications CDMA GSM Paging
1800
17
62
15
63
4.0
-2
-7
±2.5
±1.8
1900
17
62
15
63
4.0
-2
-7
±2.5
±1.8
900
16
67
14
69
4.0
-2
-7
±2.0
±1.5
1800
17
67
15
69
4.0
-2
-7
±2.5
±1.8
1900
17
67
15
69
4.0
-2
-7
±2.5
±1.8
TDMA
900
16
14
4.0
-2
-7
±2.0
±1.5
800
16
73
14
74
4.0
-2
-7
±2.0
±1.5
1900
17
73
15
74
4.0
-2
-7
±2.5
±1.8
LMR/iDEN SMR
800
16
74
14
75
4.0
-2
-7
±2.0
±1.5
900
16
74
14
75
4.0
-2
-7
±2.0
±1.5
800/1900 900/1900 900/1900 900/1800
-13
25
-13
25
-13
25
-13
25
Downlink
Four Antenna ports RHU Spcifications
Nominal Output Power at Antenna Port
Per Carrier Per Band (dBm)
Composite (1 Carrier)
2 carriers
4 carriers
10 carriers
Nominal Gain (dB)
One Antenna port RHU Spcifications
Nominal Output Power at Antenna Port
Per Carrier Per Band (dBm)
Composite (1 Carrier)
2 carriers
4 carriers
10 carriers
Nominal Gain (dB)
Common Spcifications
Nominal Input Power at Antenna Port
Per Carrier Per Band (dBm)
Composite (1 Carrier)
2 carriers
4 carriers
10 carriers
Gain Flatness (dB)
Over Band
Over Block
Max. Intermodulation Distortion (dBm)
Output 1dB Compression Point (dBm)
Spectral Regrowth (CDMA only)
Link Specifications
800/1900
GSM
11
8
5
7
14
11
8
10
4
1
-2
±2.5
±1.8
-30
25
Paging
20
17
14
10
14
24
21
18
14
18
6
3
0
-4
±2.0
±1.5
PCS*
14 / 17
10 / 14
8 / 11
– / 7
10
18 / 21
14 / 18
12 / 15
– / 12
14
4 / 7
0 / 4
-2 / 1
– / -3
±2.5
±1.8
SMR
20
17
14
10
14
24
21
18
14
18
6
3
0
-4
±2.0
±1.5
PCS*
14 / 17
10 / 14
8 / 11
– / 7
10
18 / 21
14 / 18
12 / 15
– / 12
14
4 / 7
0 / 4
-2 / 1
– / -3
±2.5
±1.8
Cellular**
14 / 20
10 / 17
8 / 14
– / 10
14
18 / 24
14 / 21
12 / 18
– / 14
18
0 / 6
-4 / 3
-6 / 0
– / -4
±2.0
±1.5
PCS*
14 / 17
10 / 14
8 / 11
– / 7
10
18 / 21
14 / 18
12 / 15
– / 12
14
4 / 7
0 / 4
-2 / 1
/ -3
±2.5
±1.8
iDEN/LMR
20
17
14
10
14
24
21
18
14
18
6
3
0
-4
±2.0
±1.5
PCS*
14 / 17
10 / 14
8 / 11
– / 7
10
18 / 21
14 / 18
12 / 15
– / 12
14
4 / 7
0 / 4
-2 / 1
– / -3
±2.5
±1.8
GSM/E-GSM
11
8
5
7
14
11
8
10
4
1
-2
±2.0
±1.5
-36
25
IS - 95 , J-STD - 008
Downlink
Link Specifications
CDMA GSM LMR/iDEN TDMA
1900
17
14
11
7
10
21
18
15
11
14
7
4
1
-3
±2.5
±1.8
-13
25
800
20
17
14
10
14
24
21
18
14
18
6
3
0
-4
±2.0
±1.5
-13
25
800
20
17
14
10
14
24
21
18
14
18
6
3
0
-4
±2.0
±1.5
-13
25
1900
17
14
11
7
10
21
18
15
11
14
7
4
1
-3
±2.5
±1.8
-13
25
1800
11
8
5
1
7
14
11
8
10
4
1
-2
-6
±2.5
±1.8
-30
25
900
11
8
5
1
7
14
11
8
10
4
1
-2
-6
±2.0
±1.5
-36
25
1900
14
10
8
10
18
14
12
14
4
0
-2
±2.5
±1.8
-13
25
1800
14
10
8
10
18
14
12
14
4
0
-2
±2.5
±1.8
-13
25
800
14
10
8
14
18
14
12
18
0
-4
-6
±2.0
±1.5
-13
25
SMR
900
20
17
14
10
14
24
21
18
14
18
6
3
0
-4
±2.0
±1.5
-13
25
Paging
900
20
17
14
10
14
24
21
18
14
18
6
3
0
-4
±2.0
±1.5
-13
25
IS - 95 , J-STD - 008
Four Antenna ports RHU Spcifications
Nominal Output Power at Antenna Port
Per Carrier (dBm)
Composite (1 Carrier)
2 carriers
4 carriers
10 carriers
Nominal Gain (dB)
One Antenna Port RHU Spcifications
Nominal Output Power at Antenna Port
Per Carrier (dBm)
Composite (1 Carrier)
2 carriers
4 carriers
10 carriers
Nominal Gain (dB)
Common Spcifications
Nominal Input Power at Antenna Port
Per Carrier (dBm)
Composite (1 Carrier)
2 carriers
4 carriers
10 carriers
Gain Flatness (dB)
Over Band
Over Block
Max. Intermodulation Distortion (dBm)
Output 1dB Compression Point (dBm)
Spectral Regrowth (CDMA only)
µ ∂A
Dual Band - RF SpecificationsSingle Band - RF Specifications
* Specifications for PCS: CDMA / TDMA & GSM 1900.
** Specifications for Cellular: CDMA / TDMA 800.
800/1900 900/1900 900/1900 900/1800
Uplink
Link Specifications
800/1900
GSM
20
65
18
67
4.0
-2
-7
±2.5
±1.8
Paging
20
18
4.0
-2
-7
±2.0
±1.5
PCS*
20
71
18
72
4.0
-2
-7
±2.5
±1.8
SMR
20
71
18
72
4.0
-2
-7
±2.0
±1.5
PCS*
20
71
18
72
4.0
-2
-7
±2.5
±1.8
Cellular**
20
71
18
72
4.0
-2
-7
±2.0
±1.5
PCS*
20
71
18
72
4.0
-2
-7
±2.5
±1.8
iDEN/LMR
20
71
18
72
4.0
-2
-7
±2.0
±1.5
PCS*
20
71
18
72
4.0
-2
-7
±2.5
±1.8
GSM/EGSM
20
65
18
67
4.0
-2
-7
±2.0
±1.5
Four Antenna Ports RHU Spcifications
Max. NF (dB)
SFDR
One Antenna Port RHU Spcifications
Max. NF (dB)
SFDR
Common Spcifications
Nominal Gain (dB)
Min. Input IP3 (dBm)
Output 1dB Compression Point (dBm)
Gain Flatness (dB)
Over Band
Over Block
Uplink
Four Antenna Ports RHU Spcifications
Max. NF (dB)
SFDR
One Antenna Ports RHU Spcifications
Max. NF (dB)
SFDR
Common Spcifications
Nominal Gain (dB)
Min. Input IP3 (dBm)
Output 1dB Compression Point (dBm)
Gain Flatness (dB)
Over Band
Over Block
800
16
62
14
63
4.0
-2
-7
±2.0
±1.5
Link Specifications CDMA GSM Paging
1800
17
62
15
63
4.0
-2
-7
±2.5
±1.8
1900
17
62
15
63
4.0
-2
-7
±2.5
±1.8
900
16
67
14
69
4.0
-2
-7
±2.0
±1.5
1800
17
67
15
69
4.0
-2
-7
±2.5
±1.8
1900
17
67
15
69
4.0
-2
-7
±2.5
±1.8
TDMA
900
16
14
4.0
-2
-7
±2.0
±1.5
800
16
73
14
74
4.0
-2
-7
±2.0
±1.5
1900
17
73
15
74
4.0
-2
-7
±2.5
±1.8
LMR/iDEN SMR
800
16
74
14
75
4.0
-2
-7
±2.0
±1.5
900
16
74
14
75
4.0
-2
-7
±2.0
±1.5
800/1900 900/1900 900/1900 900/1800
-13
25
-13
25
-13
25
-13
25
Downlink
Four Antenna ports RHU Spcifications
Nominal Output Power at Antenna Port
Per Carrier Per Band (dBm)
Composite (1 Carrier)
2 carriers
4 carriers
10 carriers
Nominal Gain (dB)
One Antenna port RHU Spcifications
Nominal Output Power at Antenna Port
Per Carrier Per Band (dBm)
Composite (1 Carrier)
2 carriers
4 carriers
10 carriers
Nominal Gain (dB)
Common Spcifications
Nominal Input Power at Antenna Port
Per Carrier Per Band (dBm)
Composite (1 Carrier)
2 carriers
4 carriers
10 carriers
Gain Flatness (dB)
Over Band
Over Block
Max. Intermodulation Distortion (dBm)
Output 1dB Compression Point (dBm)
Spectral Regrowth (CDMA only)
Link Specifications
800/1900
GSM
11
8
5
7
14
11
8
10
4
1
-2
±2.5
±1.8
-30
25
Paging
20
17
14
10
14
24
21
18
14
18
6
3
0
-4
±2.0
±1.5
PCS*
14 / 17
10 / 14
8 / 11
– / 7
10
18 / 21
14 / 18
12 / 15
– / 12
14
4 / 7
0 / 4
-2 / 1
– / -3
±2.5
±1.8
SMR
20
17
14
10
14
24
21
18
14
18
6
3
0
-4
±2.0
±1.5
PCS*
14 / 17
10 / 14
8 / 11
– / 7
10
18 / 21
14 / 18
12 / 15
– / 12
14
4 / 7
0 / 4
-2 / 1
– / -3
±2.5
±1.8
Cellular**
14 / 20
10 / 17
8 / 14
– / 10
14
18 / 24
14 / 21
12 / 18
– / 14
18
0 / 6
-4 / 3
-6 / 0
– / -4
±2.0
±1.5
PCS*
14 / 17
10 / 14
8 / 11
– / 7
10
18 / 21
14 / 18
12 / 15
– / 12
14
4 / 7
0 / 4
-2 / 1
/ -3
±2.5
±1.8
iDEN/LMR
20
17
14
10
14
24
21
18
14
18
6
3
0
-4
±2.0
±1.5
PCS*
14 / 17
10 / 14
8 / 11
– / 7
10
18 / 21
14 / 18
12 / 15
– / 12
14
4 / 7
0 / 4
-2 / 1
– / -3
±2.5
±1.8
GSM/E-GSM
11
8
5
7
14
11
8
10
4
1
-2
±2.0
±1.5
-36
25
IS - 95 , J-STD - 008
Downlink
Link Specifications
CDMA GSM LMR/iDEN TDMA
1900
17
14
11
7
10
21
18
15
11
14
7
4
1
-3
±2.5
±1.8
-13
25
800
20
17
14
10
14
24
21
18
14
18
6
3
0
-4
±2.0
±1.5
-13
25
800
20
17
14
10
14
24
21
18
14
18
6
3
0
-4
±2.0
±1.5
-13
25
1900
17
14
11
7
10
21
18
15
11
14
7
4
1
-3
±2.5
±1.8
-13
25
1800
11
8
5
1
7
14
11
8
10
4
1
-2
-6
±2.5
±1.8
-30
25
900
11
8
5
1
7
14
11
8
10
4
1
-2
-6
±2.0
±1.5
-36
25
1900
14
10
8
10
18
14
12
14
4
0
-2
±2.5
±1.8
-13
25
1800
14
10
8
10
18
14
12
14
4
0
-2
±2.5
±1.8
-13
25
800
14
10
8
14
18
14
12
18
0
-4
-6
±2.0
±1.5
-13
25
SMR
900
20
17
14
10
14
24
21
18
14
18
6
3
0
-4
±2.0
±1.5
-13
25
Paging
900
20
17
14
10
14
24
21
18
14
18
6
3
0
-4
±2.0
±1.5
-13
25
IS - 95 , J-STD - 008
Four Antenna ports RHU Spcifications
Nominal Output Power at Antenna Port
Per Carrier (dBm)
Composite (1 Carrier)
2 carriers
4 carriers
10 carriers
Nominal Gain (dB)
One Antenna Port RHU Spcifications
Nominal Output Power at Antenna Port
Per Carrier (dBm)
Composite (1 Carrier)
2 carriers
4 carriers
10 carriers
Nominal Gain (dB)
Common Spcifications
Nominal Input Power at Antenna Port
Per Carrier (dBm)
Composite (1 Carrier)
2 carriers
4 carriers
10 carriers
Gain Flatness (dB)
Over Band
Over Block
Max. Intermodulation Distortion (dBm)
Output 1dB Compression Point (dBm)
Spectral Regrowth (CDMA only)

Navigation menu