MA 1000 Installation and Configuration Guide  11 2.1.1.1  RHU 1000 Front Panel The RHU 1000 front panel contains the fiber optic connections to the BU, four coax connections to the antennas, power connections and status indicators.  If RHU 1000 and MA 1200 add-on units are installed, then the combined services are fed to the coax infrastructure through the RHU 1000 antenna ports. However, if MA 850 is also installed, the combined data and voice services are fed to the coax infrastructure through the MA 850 antenna ports. NOTE:  To provide alarms, the antenna must supply a DC resistance of up to 5K ohms.  Figure  2-1. RHU 1000 Front Panel Table  2-1. RHU 1000 Front Panel Ports Port  Description From Base To Base  Fiber Optic connections to- and from the Base Unit RS232  Upgrade and service connection (MA service personnel) PWR  DC power connection Port 1-4  Coax connections to antennas  Table  2-2. RHU 1000 Front Panel Indicators LED  Description COMM  Active communication detected LINK  Optical link to BU detected PWR  DC power connected
MA 1000 Installation and Configuration Guide  12 2.1.1.2  RHU 1000 Rear Panel The RHU 1000 rear-panel provides the connections to an MA 1200 add-on unit.   Figure  2-2. RHU 1000 Rear Table  2-3. RHU 1000 Rear Panel Connectors Add-on control  Transmits the control signals from MA 1200 add-on module to the  RHU 1000 module. Connected to the MA 1200 add-on Control From port.  High Band  Connects to the 1200 Add-on High Band port. Provides the interface to the Add-on RF service which is combined with the RHU services and distributed through the common coax infrastructure.  DL, UL  Transmit the RF signals to- and from- the MA 1200 add-on module. These ports are connected to the corresponding ports on the MA 1200 rear panel: DL to DL, UL to UL.
MA 1000 Installation and Configuration Guide  13  2.1.2 RHU 800/900 RHU 800/900 supports iDEN and SMR technologies. The module is available in the following configurations: A) As a stand-alone module similar in its physical description, ports, LEDs and installation procedure to RHU 1000 modules. The standalone module is illustrated below.  B) As a bracket assembly that includes the module and the external filter elements as illustrated below.    Figure  2-3. RHU 800/900 Front View  The following sections provide descriptions of the RHU 800/900 front and rear panel. The installation of each type of module is described in section  4.3.3.  BracketFilter
MA 1000 Installation and Configuration Guide  14 2.1.2.1  RHU 800/900 Front Panel The RHU 800/900 front panel ports and LEDs is the same  as the RHU 1000 front panel. Refer to section  2.1.1.1 for a detailed description of the LEDs and ports.  2.1.2.2  RHU 800/900 Rear Panel The rear panel contains the 1200 add-on and the filter connections.    Figure  2-4. RHU 1000 Rear Table  2-4. RHU 1000 Rear Panel Connectors Port  Description EXT FILTER  Connections to external filter (as illustrated in the following section). In installations without a filter, the two EXT FILTER ports are interconnected with a jumper. Add-on control  Connection to MA 1200 Add-on module.  Transmits the control signals from MA 1200 add-on module to the  RHU 1000 module. Connected to the MA 1200 add-on Control From port.  High Band  Connection to MA 1200 add-on module.  Connects to the 1200 Add-on High Band port. Provides the interface to the Add-on RF service which is combined with the RHU services and distributed through the common coax infrastructure.  DL, UL  Connection to MA 1200 add-on module.  Transmit the RF signals to- and from- the MA 1200 add-on module. These ports are connected to the corresponding ports on the MA 1200 rear panel: DL to DL, UL to UL.
MA 1000 Installation and Configuration Guide  15  2.1.2.3  RHU 800/900 View of Filter Connection The following figures illustrate the RHU 800/900 views with and without a filter. NOTE:  Note that the filter port connections are interconnected with a jumper in installations without a filter.  Figure  2-5. Rear View of RHU 800/900 with Filter   Figure  2-6. Rear View of RHU 800/900 without Filter  Filter connections Shorted filter connections since no filter is installed
MA 1000 Installation and Configuration Guide  16  2.1.3  MA 1200 Add-on The MobileAccess 1200 Add-on module is a high power module, supporting a single frequency band (low or high). It is designed to be integrated with a host RHU 1000 module. The RHU 1000 module provides the following functionality for both units: • Optical interface (to the BU) and conversion • RF interface (to antennas) and conversion • Control signals  In addition, MA 850 services can also be combined with MA 1200 add-on and RHU 1000 services. (However, in this type of configuration the combined services interface to the coax infrastructure through the MA 850 ports.) NOTE:  The units are integrated through simple external cable connections between corresponding ports. 2.1.3.1  MA 1200 Front Panel The RHU 1200 front panel contains the power connection and status LEDs. (The RS-232 connector is reserved for MA service personnel).     Figure  2-7. RHU 1200 Front panels Table  2-5. MobileAccess 1200 Front Panel Indicators LED  Description RUN  When blinking, indicates that the RHU is in normal operating mode. PWR Power ON  MA service connectorPower connector
MA 1000 Installation and Configuration Guide  17  2.1.3.2  MA 1200 Rear Panel The RHU 1200 rear panel contains the connections to the RHU 1000 and MA 850.    Figure  2-8. RHU 1200 Rear Panel Table  2-6. RHU 1200 Rear Panel Connectors Add-on Control   Transmits the control signals between the MA 1200 module and the MA 850 and RHU 1000 modules.  From – receives control signals from the RHU 1000. Connected to the RHU 1000 Add-on Control connector. To – Future option.  DL, UL  Transmit the RF signals to- and from- the MA 1200 add-on module. These ports are connected to the corresponding ports on the MA 1000 rear panel: DL to DL, UL to UL. High  RF service output port connected to the RHU 1000 rear-panel High port.  2.1.4 MA-850 Module NOTE: This section provides a brief overview of the MA 850 module. For detailed information on installation and connections, refer to the MA 850 Installation and Configuration Guide. MobileAccess 850 provides a secure and centralized connection for 802.11a/b/g Access Points. It significantly expands 802.11 coverage and enables distributing data and voice services over the same coax and antenna infrastructure used by MA 1000 system.  MA 850 may be assembled on top of the RHU 1000 or MA 1200 add-on. It is integrated into the MA 1000 system by interconnecting the appropriate connectors. The combined signals of the MA 1000 system input to the MA 850 module and then distributed through the same coax broadband antenna infrastructure connected to the MA 850. RHU 1000 Add-on controlMA 850 Add-on control To RHU 1000 High, DL and UL connectors.
MA 1000 Installation and Configuration Guide  18 MA 850 may be remotely monitored through the RHU 1000 system to which it is integrated, and remotely configured through a point-to-point Ethernet connection. The MA 850 front and rear panels, connectors and connections are described in detail in the following sections. 2.1.4.1  MA 850 Front Panel The MA 850 front panel contains the antenna ports interfaces, local configuration interface and power connection. NOTE: Whether connected alone or integrated with RHU 1000 modules, the coax infrastructure is connected to the MA 850 coax ports. The following figure shows the MA 850 front panel.    Figure  2-9. MobileAccess 850 Front View  Table  2-7. MA 850 Front Panel Connections Front Panel  Description Mobile Services  Four SMA female connections to which the antenna port of the MA 1000 system are connected.    To be terminated with 50 ohm terminations when not in use. Antenna Ports  Four n-type female antenna connections Local  Local connection for setup DC  Power connection: 20V to 48V from a standard power supply  Antenna ports Connections to corresponding antenna ports of remote unit Local RS232 connection  for configuration Power
MA 1000 Installation and Configuration Guide  19  2.1.4.2  MA 850 Rear Panel The MA 850 rear panel contains the connections to the APs, the Ethernet port for remote configuration and the connection to the MA 1200 add-on control (if an MA 1200 add-on unit is installed)    Figure  2-10. MobileAccess 850 Rear View Table  2-8. MA 850 Reart Panel Connections Rear Panel  Description 802.11b,g APs  Connection to up to four 802.11b/g APs, where associated LED Lite under the following conditions: • Green: indicates where AP should be connected after configuration • Green flickering: Link with AP established but no data is received • Red: AP transmitting data 802.11a APs  Connection to up to four 802.11a APs Connection to control Connection to MA 1200 To connector on the rear panel. Used for viewing antenna status Ethernet port  Connection to network for Web configuration  802.11 b/g APs connectionsEthernet Port 802.11 a APs connections Connection to add-on control
MA 1000 Installation and Configuration Guide  20   2.2 Radio Interface Unit (RIU) The RIU is an operator dedicated unit that interfaces to up to three BTS sources and automatically adjusts the signal output according to changing environmental conditions in order to provide optimal coverage for the site. The RIU is remotely monitored and managed. Each RIU can support up to three BTS Conditioner (BTSC) sub-modules, where each sub-module provides interface to a BTS or BDA of the same type of service.   Each RIU can be connected to four 8-port Base Units (real panel connections) or to eight 4-port Base Units.   Additional BUs can be supported by using splitters and combiners connected to the front panel Expansion connectors.  The following figures shows an RIU with three BTSC sub-modules.    Figure  2-11. RIU  Note: All connections are via RG223 coax cables with 1/2" N-type male connectors  ATTENTION The RIU is factory set to 0dB gain on the uplink and downlink. In order to operate properly, an ADJUSTMENT process is required in the field. Any unused input and output connectors MUST be terminated with 50 ohms – otherwise the ADJUSMENT procedure results may be affected.
MA 1000 Installation and Configuration Guide  21  2.2.1.1 RIU Front Panel The RIU front panel contains the indicators and expansion connectors for the connection of additional BUs.      Figure  2-12.  RIU Front Panel Table  2-9.  RIU Front Panel Indicators LED Description P.S UNIT PWR  ON – input signal is at the required level. BTS CONDITIONER RUN  Flashing -- CPU is running and software loaded BTS CONDITIONER DL OVERLOAD Continuous Red – RF switch is disconnected to protect the system. This may be due to:  • Unpredicted power rise for which the attenuation response was insufficient to compensate and reduce the power to the required level.   • Software problem detected. Flashing:  When the BTSC DL output power is more than 3dB of the calibrated value. BTS CONDITIONER DL LOW Continuous Red – if the BTSC DL power is at least 15dB lower than the calibrated BTSC max power level.  This condition also triggers an event.  Power Supply  BTS Conditioners Expansion connectors - for connecting additional BUs
MA 1000 Installation and Configuration Guide  22 2.2.1.2  RIU Rear Panel The rear-panel provides all the connections on the BTS side and on the BU side as well as connections to the MobileAccess 410/430 controller and the power connection. Two types of BTS side connections are available for each BTS conditioner: simplex and duplex.     Figure  2-13. RIU Rear Panel showing the RF Connection 2.3 MA Base Units  The BUs (Base Units) perform RF to optical conversion of the signal on the BTS/BDA side. Each can support up to two services (provided by the same operator). Two models of MA BUs are available: four-port unit – supporting four RHUs, and eight-port unit supporting up to eight RHUs.  The RHU models correspond to the services supplied through the BUs.   The BU (and all the corresponding remote units) may be remotely monitored and managed via the MA NMS (Network Management System).  The BUs are usually installed in the telecom room adjacent to the BTS/BDA signal source. RF ports on the rear panel provide interface to the BTS side (through connection to RIU or passive interface), while optic ports on the front panel provide interface to the RHUs (Remote Units). This following sections describe the MA BU front and rear panels, including indicators and connectors. BU connections; one UL and one DL connection for every group of four ports (single OPTM) on the BU.   Power MA Controller connection BTS/BDA simplex  connections BTS/BDA duplex connections
MA 1000 Installation and Configuration Guide  23 2.3.1.1  MA BU Front Panel The front panel contains the optical connections and indicators. The BU is available in two configurations: Four-port - and Eight-port BUs. The eight-port BU consists of two four-port elements where each four-port element has a dedicated set of indicators (PWR, LSR and Link 1 to Link 4 or Link 5 to Link 8).   Figure  2-14. Eight-Port MA BU Front Panel   Figure  2-15. Four-Port BU Front Panel Table  2-10. MA BU Front Panel Indicators LED  Description PWR  Power input detected for the corresponding unit. LSR  ON - laser circuitry for the corresponding element (group of four ports) is functioning correctly. Link 1-4, 5-8  ON - the optical link to/from the connected remote functions within the specifications in both directions.  Blinking - optical power from remote is lower than expected by at least 2 dBm  Four ports and corresponding indicators Four ports and corresponding indicators
MA 1000 Installation and Configuration Guide  24  2.3.1.2  BU Rear Panel The BU rear panel contains the RF, Alarms, NMS and power connections. Note that there are two uplink and two downlink RF connections to the BTS side (to an Interface Box or RIU) - each individual uplink and downlink connection corresponds to a four-port BU element. For a four-port BU, one uplink and one downlink port is connected; for an eight-port BU, two uplink and two downlink ports are connected.  For systems that include MA 430 controllers, the RS 485 port is connected to the MA 410/430 controller to enable remote monitoring and management of the BU from a central location. For systems without remote management, the Alarms dry-contact connector pins can be connected to the BTS to provide alarms functionality.    Figure  2-16. MA BU Rear Panel (RF Connections) Table  2-11. MobileAccess 1000 Rear Panel Connections Connector  Description Uplink output  Uplink connectors to be connected on BTS side. Downlink input  Downlink connectors to be connected on the BTS side.  Com Port RS485  Connection to MobileAccess 410/430 controller.  PWR   Power connection Alarms Dry-contact connections to BTS/BDA (normally closed). Relevant only for system without MA 410/430 controllers.   Pair of uplink and downlink RF  connections for interface to BTS  Alarms dry-contact tMA 410/430 Power
MA 1000 Installation and Configuration Guide  25  2.4 MobileAccess NMS System NOTE: This section provides general information on the MobileAccess 410/430 Controller.  For detailed information on the controller, configuration and connections refer to the Mobile Access NMS User’s Guide. The MobileAccess controllers enable managing and controlling the MobileAccess system elements.  All the monitoring and control operations can be performed from the Master’s location.  Two MobileAccess controller configurations are provided: MobileAccess 410 and MobileAccess 430.  The models differ in their remote access capabilities: • MobileAccess 410 provides point-to-point connectivity implemented via either direct RS232 connection or via connection to a DSPN phone line • MobileAccess 430 provides client/server management capability over TCP/IP network with enhanced monitoring and control capabilities (in addition to the connectivity options provided by MobileAccess 410).   NOTE: The MobileAccess 430 front panel is differentiated from the MobileAccess 410 front panel by the SNMP Agent Card that provides TCP/IP management capabilities.   Controller Front Panel      Figure  2-17. MobileAccess 410 Front Panel    Figure  2-18. MobileAccess 430 Front Panel Local RS232 connection (for IP address setup) LCD alarm display corresponding to Major and Minor LEDs  Major, Minor LED indicators Master/Slave configurationRun and  Power LEDs TCP/IP connectionLocal RS232 connection to Laptop  (MA 300  for Remote controller)
MA 1000 Installation and Configuration Guide  26  Controller Rear Panel Note:  The rear panels for the MobileAccess 410 and MobileAccess 430 are the same.      Figure  2-19. MobileAccess 410/430 Rear Panel DC InputGeneral purpose alarms input (MA 300).BTS alarms output  MA BU and RIU inputs Slave controller connections
   27 33  SSiittee  PPrreeppaarraattiioonn    3.1 Infrastructure Preparation This following installation rules are based on the assumption that site survey and installation planning (including power requirements) have been completed.  3.2 Installation Requirements The infrastructure preparation consists of two main phases: A. Floor Planning: Planning the distribution of the antennas on each floor to provide the required coverage.  B. Telecom Closet Planning: Planning the layout of the devices and cables in the telecom closet or shaft. This includes the MA 850, 802.11 Access Points, cabling and other voice service distribution systems that are relevant to the specific installation. 3.3 Coaxial Cable Connections 3.3.1  General Cable Installation Procedures Observe the general cable installation procedures that meet with the building codes in your area. The building code requires that all cabling be installed above ceiling level (where applicable). Each length of cable from the risers to each antenna must be concealed above ceiling.  The cable must be properly supported and maintained straight using tie-wraps,  cable trays and clamps or hangers every 10 feet (where practical above ceiling level). Where this is not practical, the following should be observed: • The minimum bending radius of the supplied ½” coax cable should be 7”. • Cable that is kinked or has a bending radius smaller than 7” must be replaced. • Cable runs that span less than two floors should be secured to suitably located mechanical structures. • The cables should be supported only from the building structure.
MA 1000 Installation and Configuration Guide  28  3.3.2  Fiber Optic Rules • Use only single mode fiber for indoor applications. • Use only 8-degree SC/APC connectors (green color). • Use only fusion splice for connecting two fibers. • Use minimum splicing/connectors to achieve minimum losses on the fibers (<0.5dB). • Use precaution while installing, bending, or connecting fiber optic cables. • Use an optical power meter and OTDR for checking the fiber optic cables. • Make sure the environment is clean while connecting/splicing fiber optic cables.  • All fiber optic connections should be cleaned prior to attaching to termination points using a dry cleaning device (i.e. Cletop or equivalent). • Fiber connector protective caps should be installed on all non-terminated fibers and removed just before they are terminated. • Verify the Fiber Optic connections. You may use the Optical Test Procedure described at the end of this manual. • Pay special attention while connecting the SC/APC connectors - you must hear the “click” when the connection is made. 3.3.3 RF Rules • Use coax RG223, 50ohm, male-to-male N-type for RF connections from the BUs to the BTS/RBS and to the RIU. • When using the MobileAccess™ system in an environment in which other indoor coverage systems are installed, it is recommended (where possible) that the antennas are placed at least two meters apart  • When bending coax cables, verify that the bending radius does not exceed the coax specifications. • Use wideband antennas supporting a range of 800Mhz to 2500Mhz  • Use a VSWR meter (i.e. Site Master or equivalent) for checking coax cables, including the antennas. (<2). The VSWR must be measured prior to terminating the RHUs in the remote communication rooms • Terminate all unused RHU and RIU ports with a 50 ohm load
MA 1000 Installation and Configuration Guide  29  3.3.4  Coax Cable Lengths and Losses Use coax ½”, 50ohm, male-to-male N-type, (6-7dB for 1Ghz, 11dB for 2Ghz) for connecting to RHU and RHU ports. Coax Length  coax Loss (900Mhz) connector loss Total Loss 30 0.7  1.5  2.2 40 0.9  1.5  2.4 50 1.1  1.5  2.6 60 1.3  1.5  2.8 70 1.5  1.5  3 80 1.7  1.5  3.2 90 1.9  1.5  3.4 100 2.1  1.5  3.6 110 2.3  1.5  3.8 120 2.5  1.5  4 130 2.7  1.5  4.2 140 2.9  1.5  4.4 150 3.1  1.5  4.6 160 3.3  1.5  4.8 170 3.5  1.5  5 180 3.7  1.5  5.2 190 3.9  1.5  5.4 200 4.1  1.5  5.6
MA 1000 Installation and Configuration Guide  30 3.3.5  Power Consumption, Connections and Power Supplies 3.3.6  Power Safety Instructions    SAFETY WARNINGS • When installing or selecting the power supplies:  • Be sure to disconnect all power sources before servicing. • Battery replacement in units - only the MA 410/430 controller has batteries. MA 410/430 Controller lithium type battery should only be replaced by MobileAccess service personnel. Risk of exploding if battery is replaced by an incorrect type. Dispose of used batteries according to the instructions. • Calculate the required power according to the requirements of the specific installation and then determine the configuration of the power supplies. The required DC cables will then be determined by the selected PS configuration. • Use only UL approved power supplies  • AC and DC power supply cables – use only the power cords supplied with the units  • Install external over-current protective devices for the system according to the requirements described in section  3.3.9.  3.3.7  Power Consumption of Units Table  3-1. MobileAccess™ Power Requirements Unit Type  Voltage Input Typical Power Consumption Maximum Current Consumption Remote Unit 1000  20 to 48VDC  25W  1.25A Add-on Unit 1200  25 to 48VDC  50W  2.0A RIU  20 to 48VDC  12W  0.6A Base Unit  20 to 48VDC  14W  0.7A 410/430 Controller  20 to 48VDC  10W  0.5A MA 850  20 to 48VDC  20W  1.0A