Corning Optical Communication VECELLPCSFB VE CELL PCS FULL BAND DISTRIBUTED ANTENNA SYSTEM User Manual EnCOVER Dual Band
Corning Optical Communication Wireless VE CELL PCS FULL BAND DISTRIBUTED ANTENNA SYSTEM EnCOVER Dual Band
Users Manual
User Manual MobileAccessVE Dual-Band Instant Coverage Solution User Manual P/N: 709C004904 REV: A01 Date: JUNE 2011 Preface Material MobileAccess 8391 Old Courthouse Road, Suite 300, Vienna, VA 22182 Tel: +1(866)436-9266, +1(703)848-0200 TAC: +1(800)787-1266, Fax: +1(703)848-0280 http://www.MobileAccess.com Dual-Band MobileAccessVE Instant Coverage Solution User Manual II Preface Material Preface Material © Copyright 2011, MobileAccess. All Rights Reserved. This document contains confidential and proprietary information of MobileAccess and may not be copied, transmitted, stored in a retrieval system or reproduced in any format or media, in whole or in part, without the prior written consent of MobileAccess. Information contained in this document supersedes any previous manuals, guides, specifications, data sheets or other information that may have been provided or made available to the user. This document is provided for informational purposes only, and MobileAccess does not warrant or guarantee the accuracy, adequacy, quality, validity, completeness or suitability for any purpose of the information contained in this document. MobileAccess reserves the right to make updates, improvements and enhancements to this document and the products to which it relates at any time without prior notice to the user. MobileAccess makes no warranties, express or implied, including, without limitation, those of merchantability and fitness for a particular purpose, with respect to this document or any information contained herein. Policy for Warrantee and Repair MobileAccess tests and inspects all its products to verify their quality and reliability. MobileAccess uses every reasonable precaution to ensure that each unit meets their declared specifications before shipment. Customers should advise their incoming inspection, assembly, and test personnel about the precautions required in handling and testing our products. Many of these precautions can be found in this manual. The products are covered by the following warranties: General Warranty MobileAccess warrants to the original purchaser all standard products sold by MobileAccess to be free of defects in material and workmanship for one (1) year from date of shipment from MobileAccess. During the warranty period, MobileAccess will repair or replace any product that MobileAccess proves to be defective. This warranty does not apply to any product that has been subject to alteration, abuse, improper installation or application, accident, electrical or environmental over-stress, negligence in use, storage, transportation or handling. Specific Product Warranty Instructions All MobileAccess products are warranted against defects in workmanship, materials and construction, and to no further extent. Any claim for repair or replacement of units found to be defective on incoming inspection by a customer must be made within (30) days of receipt of shipment, or within (30) days of discovery of a defect within the warranty period. This warranty is the only warranty made by MobileAccess and is in lieu of all other warranties, expressed or implied. MobileAccess sales agents or representatives are not authorized to make commitments on warranty returns. Dual-Band MobileAccessVE Instant Coverage Solution User Manual III Preface Material Returns In the event that it is necessary to return any product against above warranty, the following procedure shall be followed: 1. Return authorization is to be received from MobileAccess prior to returning any unit. Advise MobileAccess of the model, serial number, and discrepancy. The unit may then be forwarded to MobileAccess, transportation prepaid. Devices returned collect or without authorization may not be accepted. 2. Prior to repair, MobileAccess will advise the customer of our test results and any charges for repairing customer-caused problems or out-of-warranty conditions etc. 3. Repaired products are warranted for the balance of the original warranty period, or at least 90 days from date of shipment. Limitations of Liabilities MobileAccess's liability on any claim, of any kind, including negligence for any loss or damage arising from, connected with, or resulting from the purchase order, contract, quotation, or from the performance or breach thereof, or from the design, manufacture, sale, delivery, installation, inspection, operation or use of any equipment covered by or furnished under this contact, shall in no case exceed the purchase price of the device which gives rise to the claim. EXCEPT AS EXPRESSLY PROVIDED HEREIN, MOBILEACCESS MAKES NO WARRANTY, EXPRESSED OR IMPLIED, WITH RESPECT TO ANY GOODS, PARTS AND SERVICES PROVIDED IN CONNECTION WITH THIS AGREEMENT INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. MOBILEACCESS SHALL NOT BE LIABLE FOR ANY OTHER DAMAGE INCLUDING, BUT NOT LIMITED TO, INDIRECT, SPECIAL OR CONSEQUENTIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH FURNISHING OF GOODS, PARTS AND SERVICE HEREUNDER, OR THE PERFORMANCE, USE OF, OR INABILITY TO USE THE GOODS, PARTS AND SERVICE. Reporting Defects The units were inspected before shipment and found to be free of mechanical and electrical defects. Examine the units for any damage that may have been caused in transit. If damage is discovered, file a claim with the freight carrier immediately. Notify MobileAccess as soon as possible. Note: Keep all packing material until you have completed the inspection Safety Warnings To comply with FCC RF exposure compliance requirement, adhere to the following warnings: Warning! The Access Pod with its built-in antenna must be installed with a separation distance of at least 20cm from all persons and must not be located in conjunction with any other antenna. Warning! The outside antenna must be installed with a separation of at least 20cm from all persons and must not be located in conjunction with any other antenna. Warning! Use of this Access Pod with antennas other than those illustrated could be hazardous. Before using other antennas, contact MobileAccess Support. Caution: Double pole/neutral fusing (two fuses in the appliance inlet) Approved Antennas for use with the MobileAccessVE Solution The gain of external antennas connected to the VAPs should not exceed 10 dBi. Dual-Band MobileAccessVE Instant Coverage Solution User Manual IV Preface Material Compliance with RF Safety Requirements MobileAccess products have no inherent significant RF radiation. The RF level on the down link is very low at the downlink ports. Therefore, there is no dangerous RF radiation when the antenna is not connected. Certification and Compliance to Standards Category Standards Safety: IEC 60950-1: 2003; UL-60950-1:2003; CAN/CSA – C22.2 No 60950-1-03 EN 301489-8 V1.2.1:2002; EN 301489-1 V1.5.1:2004; EN 61000 V4.6:2005 EMC: Radio: EN 55022 V4.2:2001 / FCC Part 15; VCCI Class A for VCU and Class B for VAP GSM/DCS EN-301502 V8.1.2: 2001; EN-301908 v3.2.1:2006; EN 300 609-4 V8.02:2000 CELL/PCS FCC Part 24 UMTS SAR Body Testing EN 301 908-11 EN 50385 & FCC OET65C:2001 Dual-Band MobileAccessVE Instant Coverage Solution User Manual Preface Material About This Guide This guide provides essential product functionality with all the information necessary for proper installation and configuration of the MobileAccessVE system. List of Acronyms Abbreviation Description DB Dual-Band PoE Power Over Ethernet STP Shielded Twisted Pair UTP Unshielded Twisted Pair VAP VE Access Pod VCU VE Control Unit UMTS Universal Mobile Telecommunications System EGSM Extended Global System for Mobile Communications PCS Personal Communications Service DCS Digital Cellular System Dual-Band MobileAccessVE Instant Coverage Solution User Manual VI Table of Contents Overview .............................................................................................................................1 1.1 Key Features and Capabilities ....................................................................................................... 2 1.2 System Architecture ..................................................................................................................... 3 1.3 System Elements ......................................................................................................................... 4 1.3.1 VE Control Unit (VCU) ......................................................................................................... 4 1.3.1.1 VCU Front Panel ..................................................................................................... 4 1.3.1.2 VCU Rear Panel ...................................................................................................... 6 1.3.2 VE Access Pod (VAP) .......................................................................................................... 6 1.4 System Monitoring and Management............................................................................................. 8 1.4.1 Integration with an External Fault Management System ........................................................ 8 Installation Workflow .........................................................................................................9 Infrastructure Requirements and Layout Planning........................................................10 3.1 General Information on Location and Connections ....................................................................... 10 3.2 Infrastructure Requirements ....................................................................................................... 11 3.3 Coverage and Installation Planning ............................................................................................. 12 3.3.1 Types of Environments ..................................................................................................... 12 3.3.1.1 Standard Environment .......................................................................................... 13 3.3.1.2 Open Environment ............................................................................................... 13 3.3.1.3 Dense Environment: ............................................................................................. 13 3.3.1.4 Combination of Environments ............................................................................... 14 3.4 Planning VAP Layout .................................................................................................................. 14 3.4.1 RF Coverage Factors ......................................................................................................... 14 3.4.2 Mapping Locations ............................................................................................................ 14 3.4.3 Optional Directional Antennas ........................................................................................... 15 3.4.4 Installation Plan Example .................................................................................................. 15 VCU Unit Installation and Provisioning ..........................................................................17 4.1 VCU Kit Contents ....................................................................................................................... 17 4.2 VCU Physical Installation ............................................................................................................ 18 4.2.1 Master VCU Installation..................................................................................................... 18 4.2.1.1 Master VCU Alarm Output Connections .................................................................. 19 4.2.2 Slave VCUs Installation ..................................................................................................... 20 Dual-Band MobileAccessVE Instant Coverage Solution User Manual VII Table of Contents 4.3 Ethernet Cable Connections to VAPS ........................................................................................... 22 4.3.1 Shifting Relevant Ethernet LAN Connections ....................................................................... 22 4.3.2 Operation with LAN Utilizing Power over Ethernet (PoE) ..................................................... 23 4.4 Provisioning the VE Control Unit.................................................................................................. 24 4.4.1 Configure the Computer IP Parameters .............................................................................. 24 4.4.2 Provisioning the Master VCU Unit ...................................................................................... 25 4.4.3 Provisioning the Slave VCUs .............................................................................................. 32 VAP Installation and Provisioning ..................................................................................34 5.1 VAP Installation ......................................................................................................................... 34 5.2 Desk and Wall Mount VAP Installations ....................................................................................... 35 5.2.1.1 VAP Kit Contents .................................................................................................. 35 5.2.1.2 Desk Mount Installation ........................................................................................ 36 5.2.1.3 Wall Mount Installation ......................................................................................... 37 5.2.2 Horizontal Ceiling Mount VAP Installations ......................................................................... 38 5.2.2.1 VAP Kit Contents .................................................................................................. 38 5.2.2.2 Lowered Ceiling Installation .................................................................................. 39 5.2.2.3 Concrete/Wood Ceiling Installation ........................................................................ 40 5.2.3 Vertical Ceiling Mount VAP Installations ............................................................................. 42 5.2.3.1 VAP Kit Contents .................................................................................................. 42 5.2.3.2 Lowered Ceiling Installation .................................................................................. 43 5.2.3.3 Concrete/Wood Ceiling Installation ........................................................................ 44 5.3 Verifying Coverage ..................................................................................................................... 45 5.4 Naming the VAPs, Verifying Connections, and Monitoring ............................................................. 46 Navigating the Web Access Application ........................................................................49 6.1 Opening a Session and Authentication Levels .............................................................................. 49 6.2 About the MobileAccessVE Web Access Window........................................................................... 50 6.3 Configuration Tab ...................................................................................................................... 51 6.3.1 Network Topology Tree .................................................................................................... 52 6.3.1.1 Removing Network Element from Baseline ............................................................. 53 6.3.2 Configuration Display Area ................................................................................................ 54 6.4 Management Tab ....................................................................................................................... 55 VCU Monitoring and Configuration.................................................................................56 7.1 Viewing VCU General Information ............................................................................................... 56 7.2 Viewing VCU Alarms ................................................................................................................... 57 7.3 Master VCU RF Parameters ......................................................................................................... 58 Dual-Band MobileAccessVE Instant Coverage Solution User Manual VIII Table of Contents VAP Monitoring and Configuration .................................................................................60 8.1 Viewing VAP General Information ............................................................................................... 60 8.2 Viewing VAP Alarms ................................................................................................................... 61 8.3 VAP RF Parameters .................................................................................................................... 62 Administrative Operations...............................................................................................64 9.1 Changing Password .................................................................................................................... 64 9.2 Retrieving VCU IP Address .......................................................................................................... 65 9.3 IP Settings ................................................................................................................................ 67 9.4 SNMP Configuration Parameters ................................................................................................. 68 9.5 Upgrading (or Downgrading) VCU and VAP Software ................................................................... 69 9.5.1 Upgrading the VAP SW ..................................................................................................... 70 9.5.2 Upgrading the VCU SW ..................................................................................................... 72 10 Troubleshooting ...............................................................................................................73 10.1 Finding a Specific VAP in the Building .......................................................................................... 73 10.2 Wireless Service is Not Available ................................................................................................. 75 10.3 PoE is Not Working .................................................................................................................... 75 10.4 Ethernet Service is Degraded ...................................................................................................... 76 10.5 No Service from Connected Access Pod ....................................................................................... 76 10.6 VCU Cannot be Monitored via SNMP ............................................................................................ 78 Appendix A - Traps .................................................................................................................79 VE Control Unit (VCU) Traps .............................................................................................................. 79 VE Access Pod (VAP) Traps ................................................................................................................ 79 Appendix B – MobileAccess VE Dual Band MIB Tree Structure (Version 1.8)....................80 MobileAccess Version 1.8 MIBs/OID Descriptions ................................................................................ 83 Dual-Band MobileAccessVE Instant Coverage Solution User Manual IX 1 Overview The MobileAccessVE Dual-Band solution provides enhanced, cost effective, in-building coverage of two services (from a range of available service combinations) for any (small-to-large) sized enterprise environment. This solution is quickly and easily deployed using the existing Ethernet cabling infrastructure, without affecting existing LAN services or performance. The VE solution converges wireless services from the service provider’s equipment and Ethernet services from the corporate LAN, via a VE Control Unit located in the communication closet. The converged services are routed to VE Access Pods (VAPs) installed throughout the enterprise. The VAPs are distributed on each floor and plug into existing standard Ethernet jacks. The VAPs provide wireless services coverage via integrated internal antennas (or optional external antennas). The VAPs also provide Ethernet connectivity to the LAN terminals (that were previously connected to the jacks). They are powered via Power over Ethernet (PoE) technology and managed via the VCU located in the floor’s IDF/Telco closet. For site coverage that requires more than one VCU, several VCUs can be aggregated under a single Master VCU. The Master VCU provides the interface to the carrier’s capacity sources and management. MobileAccessVE seamlessly coexists with the Enterprise LAN and does not consume LAN capacity. This enhanced Dual-Band coverage solution can be quickly and easily installed with minimal disturbance to the enterprise. In less than a few hours and with no additional cables being required, a scalable and flexible solution is provided at a significantly lower total installation cost. Currently, the VE Dual-Band system is available for the following band combinations: • EGSM-UMTS • CELL-PCS Full Band • DCS-UMTS The following figures illustrate single-tier and multi-tier VE installations. In a single-tier installation the VCU is connected to both the service provider’s equipment and the Ethernet switch, and distributes Ethernet and mobile services to up to 12 VAPs distributed over one more adjacent floors. Dual-Band MobileAccessVE Instant Coverage Solution User Manual Overview Figure 1-1. Single-Tier VE Installation Multi-tier installation includes the Master VCU that supports up to 12 Slave VCUs. In this type of installation the provider’s services are fed to the Master VCU through which the Slave VCUs are controlled and managed. Figure 1-2. Multi-Tier VE Installation 1.1 Key Features and Capabilities • Supports the following frequency ranges: • EGSM: 925 – 960; UMTS: 2110 - 2170 • DCS: 1805 – 1880; UMTS: 2110 - 2170 • Full Band CELL: 869 – 894; Full Band PCS: 1930 - 1990 • Simple installation - Deployed in only a few hours, with minimum disturbance to the enterprise. • VAPs connect over existing CAT-5e/6 cabling infrastructure and utilize existing Ethernet jacks. • VAPs are remotely powered using Power-over-Ethernet (PoE). Local power is not required. • Minimum macro-network impact with low power distributed coverage. • Seamlessly coexists with the Enterprise LAN and does not consume LAN capacity. • Connects to all types of capacity sources: BTS, Picocells, Femtocells and BDAs. • VAPs can be easily relocated for coverage modifications as needed. • Ease of expansion provides “pay as you grow” scalability. • Support of connected IP devices (Wi-Fi APs, IP Phones, etc) with Ethernet/IP pass through and PoE maximizes placement flexibility. • Baseline feature that clearly shows VAPs and VCUs in which communication has been lost and generates corresponding alarms. • Remote end-to-end system monitoring, management, and configuration via a single connection to the master VCU using a standard web browser and SNMP. Dual-Band MobileAccessVE Instant Coverage Solution User Manual Overview 1.2 System Architecture Main Elements - The MobileAccessVE solution is based on the following main elements: • VE Control Unit (VCU) – installed in the communication room or shaft. Converges the Ethernet and RF signals and provides secure, central management to up to 12 VAPs or (Slave) VCUs in any combination. The same unit model can be configured either as Master or Slave depending on the installation topology: • Master VE Control Unit (Master VCU) – Installed in the main communication IDF/Telco closet, interfaces to the service provider’s RF equipment, and provides secure, central management to up to twelve VCUs and VAP devices in any combination. • Slave VE Control Unit (Slave VCU) – Used to expand coverage to additional floors. Installed in the IDF/Telco closet of the relevant floor. Each Slave VCU interfaces the Master VCU and up to twelve VAPs and twelve Ethernet connections. The Master and Slave VCUs are connected using dedicated CAT-6/7 cables. VCUs distribute wireless service signals to each VAP along with PoE and where relevant Ethernet signals from the Ethernet switch, throughout the existing CAT-5e/6 infrastructure. • VE Access Pod (VAP) – These are pluggable antennas distributed at strategic locations on the floor to provide Ethernet connection to an IP device and wireless coverage of the service via integrated internal (or external) antennas. Power to VAPs is provided via PoE from the VCU. Up to twelve VAPs can be connected to a single VCU using LAN cables (CAT-5e or higher). Note: If the total number of VAPs in the deployment exceeds 72, consult with MobileAccess support. The following figure shows the Multi-tier Dual-Band VE solution architecture. Note: If the Master VCU supports VAPs (in addition to VCUs), the relevant Ethernet ports are also connected to an Ethernet switch. Figure 1-3. VE Multi-Tier Basic Architecture Note: Connecting both VAPs and slave VCUs to the master VCU simultaneously is supported only with VE network elements running SW version 2.6 and above Dual-Band MobileAccessVE Instant Coverage Solution User Manual Overview 1.3 System Elements This section describes the interfaces of the VE Control Units and Access Pods. 1.3.1 VE Control Unit (VCU) The VCU can operate as either Master/Standalone or Slave. The front panel supports all the RF, control and optic interfaces, while the rear panel contains the power and alarms interfaces. 1.3.1.1 VCU Front Panel The VCU front panel provides interfaces to RF, management VAP, and VCU interfaces. The type of RF interfaces may vary depending on the VCU model. Below are two models: the top model supports only Duplex N-type interface, while the bottom model supports both Simplex and Duplex QMA connections. Web Management VAPs status Master Port Duplex connectors (N-type) 1 per service VAP Ports Ethernet Ports Figure 1-4. Example of VCU with Duplex RF Connectors Duplex QMA connectors Simplex QMA connectors (2 per service) Figure 1-5: Example of VCU with both Simplex and Duplex RF Connectors Dual-Band MobileAccessVE Instant Coverage Solution User Manual Overview Interfaces Description RF Source RF connections to the RF source: simplex or duplex, N-type or QMA depending on the model. Management VE Access Pod Ports 1-12 Relevant only for Master or Standalone VCU. RJ45 WEB management connection to Master or Standalone VCU. VAP and or VCU connections (in any combination): Master VCU – Connections to Slave VCUs or VAPs. Slave VCU – Connections to VAPs. Ethernet Ports 1-12 Ethernet switch connections. Relevant for VCUs with connected VAPs. Connect according to corresponding VAP connections. Master Relevant for Slave VCUs. Connection towards Master VCU VE Access Pod Ports. Reset N/A in current version. Interfaces Description PWR - VCU power source: Green - Power OK Disabled - No power received by VCU ACT VCU activity LED: Solid Green – During initialization Blinking Green – Normal operation Fast Blinking Green – User activated VCU Identify on this VCU Status of the corresponding unit (VAP or VCU) Blinking Green – Unit is initializing Solid Green – Normal operation of unit Solid Orange – Unit is faulty, or unmanaged. This can be due to mismatch type, VoIP phone, etc. Fast Blinking Green – User selected “Identify” command on the unit Off – No VAP or VCU connected to this port. Status of connected RF capacity source: Green – Master VCU only. Normal RF level Orange – Master VCU only. RF level is either too low, too high, or service has been turned off by the user. Off – VCU is Slave. Status of the connection to the Master VCU: Off – Master mode (not connected to VCU) Blinking Green – During attachment process with Master VCU Solid green – Slave (IF-IF) mode and connected to Master PWR and ACT LEDs VAP Status (One LED per Port) RF (One LED per Service) Master Table 1-1: VCU Ports Description Dual-Band MobileAccessVE Instant Coverage Solution User Manual Overview 1.3.1.2 VCU Rear Panel The rear panel includes the following: power switch, AC input, AUX alarms, and service personnel connections. Console Connector AUX Alarms Figure 1-6. VCU Rear Panel PWR On/Off Switch AC Connector Table 1-2: VCU Rear Panel Description Connector Description Console RS232 local connection for service personnel (D-Type 9) AUX Alarms Connections – (See section 4.2.1.1). In Master/Slave configuration Alarms - relevant only for Master VCU. Power Input 1.3.2 Standard 3-pins AC power connector equipped with an ON/OFF switch. 90264V AC, 47-63 Hz AC; 350W power consumption maximum. VE Access Pod (VAP) Each VAP supports: • Internal antennas and two interfaces for external antennas. By default, the VAP is set to transmit through the integrated internal antennas. To use the external antennas connectors, select the “External Antenna” option in VAP Config-Service RF tab of the VE Web GUI application (See section 8.3). • An Ethernet port for physical Ethernet connection to devices such as a computer, IP phone or Wi-Fi Access Point. • Two LED status indictors. The VAP can be mounted on the wall or placed on a flat surface. Brackets are provided for each type of installation. Dual-Band MobileAccessVE Instant Coverage Solution User Manual Overview The following figure shows the desktop VAP. Front View Blue LED (Activity and Identify) Green LED (Power) External Antenna Connectors Figure 1-7. VE Access Pod-Front Table 1-3: VAP LEDs LED Description Solid Green Off Off Power Activity - Power supplied to VAP - No power supplied to VAP - No power supplied to VAP or Overall Status of VAP is faulty Blinking Blue - Power on, VAP is initializing (connecting to VCU) Solid Blue - Power on, unit operating normally Fast Blinking Blue - User invoked “Identify” command on corresponding VAP The following figure shows the desktop VAP rear side and the underside view with the CAT-5e/6 patch-cord cable. Rear View RJ-45 Connector to LAN Terminal RJ-45 Connector to Figure 1-8. VE Access Pod Dual-Band MobileAccessVE Instant Coverage Solution User Manual Overview 1.4 System Monitoring and Management The MobileAccessVE system (Master VCU, Slave VCUs, and VAPs) is centrally managed via a single Web connection to the Master VCU. The basic screen in the GUI is the Config tab, which enables the user to view the system topology and setup parameters, control units, and all Access Pods connected to the control units. Note: When locally connecting to a specific Slave VCU, only the VAPs connected to this VCU can be monitored. When connected to the Master, the entire deployment can be monitored. The following figure shows the Master VCU with a single Slave VCU and its nine VAPs. The session is opened by a connection to the Master VCU. 1.4.1 Integration with an External Fault Management System The MobileAccessVE system can be seamlessly integrated into any existing Fault Management (FM) system that supports SNMP events. The Master VCU generates a SNMP event for each relevant system alarm and forwards this trap to the pre-configured IP address of the external Fault Management system. Dual-Band MobileAccessVE Instant Coverage Solution User Manual Installation Workflow Installation Workflow The following figure summarizes the main steps of the installation procedure: Installation Workflow 1. Infrastructure Preparation 2. Installation Procedure Plan the floor coverage and VAP locations according to the type/density of the site. Install the Master VCU in the IDF/telco shaft. Check that Ethernet jacks are available in all planned VAP locations. Determine the communication rooms to which the VAP infrastructure is connected (locations for the Slave VCUs). Verify that all infrastructure requirements are met (includes verifying that the jacks are wired to the patch panel in the communication rooms). Open a local session to the Master VCU and configure the system parameters (IP, and service parameters: Central Frequency , Max expected Pin). Install the RF signal sources, connect them to the master VCU (through passive interfaces) and check that the RF signals are received by the VCU (i.e. that the RF LEDs are green). Install the Slave VCUs and connect them to the Master VCU (verify that the VCU/VCH LED is green, and RF LEDs turned OFF). Connect the VCU VAP ports to the patch panel, and the Ethernet Switch to the VCU Ethernet ports. Install the VAPs and connect them to the Ethernet jacks. Connect the Ethernet appliance (if exists) to the VAP. Check that the VAP is operational (Blue LED lit). Check that Ethernet connection is OK. Perform a “walk test” and verify coverage around the floor. Met Coverage? No Change VAPs locations or add VAPs Yes Complete Dual-Band MobileAccessVE Instant Coverage Solution User Manual Infrastructure Requirements and Layout Planning Infrastructure Requirements and Layout Planning 3.1 General Information on Location and Connections • Service provider’s RF equipment (Macrocell, Microcell, Picocell, Femtocell, BDA, etc.) connects to the VCU through a passive interface. • VCUs: • Master VCU installed at the main IDF/Telco cabinet and connected to all VCUs. • Slave VCUs installed at the IDF/Telco cabinet of each covered floor and connected to the Master VCU, the Ethernet switch, and the VAPs through the cabling patch panel. • Wireless service signals from Master VCU to VCUs – Routed through dedicated Ethernet CAT-6/7 cabling. • Wireless service signals from VCUs to the VAPs – Routed through existing Ethernet CAT5e/6 cabling infrastructure. • VAP location and mounting – Wall or desk mounting. Connection to existing Ethernet jack and external antenna if required. • VAP power source - No power connections required. VAPs are power fed from VCU using PoE (Power over Ethernet) technology. Note: If the Master VCU supports VAPs in addition to VCUs, the relevant Ethernet ports are also connected to an Ethernet switch. Figure 3-1. VE Multi-Tier Basic Architecture Dual-Band MobileAccessVE Instant Coverage Solution User Manual 10 Infrastructure Requirements and Layout Planning 3.2 Infrastructure Requirements Ethernet standards specify that the maximum distance between an Ethernet switch and an appliance (computer, WLAN AP etc) should not exceed 100m (300ft). Therefore, when VE shares the IT LAN, the maximum distance for a given cable run cannot be longer than 100m (300ft) between the Ethernet switch and appliance, including all patch cords (from switch to VCU, from VCU to patch panel, from RJ-45 outlet to VAP, and from VAP to appliance). Typically the horizontal cabling system will be connected to patch-panels in the communication rooms. The entire cabling system, including the patch panels and patch cords, should adhere to the CAT-5e/6 standard. Specifically all pairs of the CAT-5e cable should be wired in the patch panels (and patch cords). 1. IDF/Telco closet space for one or more VCUs depending on the number and locations of the installed VCUs: (48.3cm x 51.3cm x 8.88cm) per VCU. Note: When planning the IDF/Telco shaft, take the RF equipment (picocell/microcell or BDA) and the VCU into consideration. 2. 350 Watts of AC power to the VCU IDF/Telco closet. 3. Building infrastructure: • CAT-5e/6 cabling, Shielded Twisted Pair (STP) • 24 AWG minimum diameter for CAT-5e cabling • Dedicated CAT-6/7 STP cable from Master VCU to Slave VCUs with run lengths NOT exceeding 100m (300ft) and no shorter than 10m (33ft). • CAT-5e/6 STP cable from VCU to each VAP with run lengths NOT exceeding 100m (300ft) and no shorter than 10m (33ft). VAPs can be connected over existing CAT-5e/6 cabling infrastructure and existing Ethernet jacks without affecting the LAN. Note: Verify with IT department that the existing cables can support the VE installation. If available, review the infrastructure documentation to determine cable types and lengths. If documentation is not available, attempt to visually identify the cable type. Depending on the cable vendor, the cable type may be listed on the cable sheath. Its’ recommended to use a Fluke cable tester to measure the cable length of the most remote VAPs. 4. Master VCU Cable Connections: • (2) N-type female, 50 ohm interfaces to carrier equipment or • (6) QMA connectors for MIMO1 and MIMO2 Simplex and Duplex connections to carrier equipment – CELL/PCS Full-Band VCUs only • Up to (12) RJ-45 interfaces to Slave VCUs and/or VAPs • (1) RJ-45 interface to Management • (1) D-Type 9 pins RS-232 interface for local craft • (1) D-Type 15 pins interface for External Alarms (dry contacts) 5. Slave VCU Cable Connections • (1) RJ-45 interface to Master VCU (not used in small single-tier deployments) • (12) RJ-45 interfaces to VAPs Dual-Band MobileAccessVE Instant Coverage Solution User Manual 11 Infrastructure Requirements and Layout Planning • (12) RJ-45 interfaces to Ethernet Switch for LAN service • (1) D-Type 9 pins RS-232 interface for local craft 3.3 Coverage and Installation Planning Note: The following section provides information required for planning the VAP installation on a single floor. In a multi-tier installation, this procedure is performed for each individual floor. The maximal coverage area of each VAP is affected by the density and type of environment being covered. Therefore, it is recommended to determine the location in two phases: • Plan the ideal location of each VAP in order to achieve complete coverage of the floor. • Select the exact location according to the location feasibility, where each VAP unit may be wall or desk mounted and an option for an external antenna is available. The supplied services (wireless only or Ethernet and wireless) depend on the jack to which the VAP is connected: • If the jack supports an active Ethernet connection, the VAP will distribute LAN traffic along with the wireless service. (See section 4.3). • If the jack is not currently active (not connected to an Ethernet switch), the VAP will distribute only the wireless services. This section provides information on coverage criteria in various types of environments (Open, Standard, Dense, and Merged) and provides rules-of-thumb for various installations of the VAPs. Note: See section 3.4, which provides a detailed example of installation planning in various types of environment. It is recommended to review this example after reading this section. 3.3.1 Types of Environments This section describes the different types of installation environments and provides guidelines for best coverage of each type of space. The coverage guidelines in this section are conservative “rule of thumb” estimates of RF coverage per VAP, meant to be used in scenarios in which detailed designs are not performed. When the coverage layout is designed, the coverage per VAP is expected to increase by up to 33%. Coverage estimates in this section assume 25% overlap between the coverage areas of neighboring VAPs to ensure robust, full coverage throughout the enterprise with no “dead zones”. The coverage guidelines in the following tables are provided for the higher frequency bands (UMTS & PCS). The lower frequency bands (DCS, EGSM & CELL) are omitted from the tables since coverage in these bands will be better than that of the higher frequency bands. The coverage of a dual-band system will be determined by the higher frequency band (i.e. PCS for CELL/PCS and UMTS for EGSM/UMTS and DCS/UMTS). Dual-Band MobileAccessVE Instant Coverage Solution User Manual 12 Infrastructure Requirements and Layout Planning 3.3.1.1 Standard Environment A standard environment is a traditional office environment with offices, hallways, and scattered cubicles. Table 3-1: Standard Environment Installation Distances Band PCS PCS UMTS Technology CDMA or GSM WCDMA WCDMA Downlink Frequency 1900 MHz 1900 MHz 2100 MHz Signal Propagation from VAP 67 feet (20.5 m) 64 feet (19.5 m) 57.5 feet (17.5 m) Recommend Spacing Between VAPs 134 feet (41 m) 128 feet (39 m) 115 feet (35 m) Recommended Maximum Distance 67 feet (20.5 m) 64 feet (19.5 m) 57.5 feet (17.5 m) of VAPs from Outer Walls Coverage Area per VAP 14,250 sqft (1,324 sqm) 12,750 sqft (1,185 sqm) 10,425 sqft (969 sqm) 3.3.1.2 Open Environment An open environment is an environment with minimal obstacles (e.g. walls). This type of space can be a large conference or meeting room, cubical areas, lobby, or an atrium. Table 3-2: Open Environment Installation Distances Band Technology Downlink Frequency Signal Propagation from VAP Recommend Spacing Between VAPs Recommended Maximum Distance of VAPs from Outer Walls Coverage Area per VAP 3.3.1.3 PCS CDMA or GSM 1900 MHz 90 feet (27 m) 180 feet (55 m) PCS WCDMA 1900 MHz 82.5 feet (25 m) 165 feet (50 m) UMTS WCDMA 2100 MHz 67 feet (20.5 m) 134 feet (41 m) 90 feet (27.5 m) 83 feet (25 m) 67 feet (20.5 m) 25,425 sqft (2,362 sqm) 21,350 sqft (1,983.5 sqm) 14,250 sqft (1,324 sqm) Dense Environment: A dense environment consists of a relatively large amount of walls, offices, equipment, tall file cabinets, bookshelves, and other items that could potentially impact the wireless signal. Examples include dense offices, hospitals, and manufacturing spaces. Table 3-3: Dense Environment Installation Distances Band PCS PCS UMTS Technology CDMA or GSM WCDMA WCDMA Downlink Frequency 1900 MHz 1900 MHz 2100 MHz Signal Propagation from VAP 64 feet (19.5 m) 60 feet (18 m) 45 feet (13.5 m) Recommend Spacing Between VAPs 128 feet (39 m) 120 feet (36 m) 90 feet (27.5 m) Recommended Maximum Distance 64 feet (19.5 m) 60 feet (18 m) 45 feet (13.5 m) of VAPs from Outer Walls Coverage Area per VAP 12,750 sqft (1,185 sqm) 11,250 sqft (1,045 sqm) 6,300 sqft (585 sqm) Dual-Band MobileAccessVE Instant Coverage Solution User Manual 13 Infrastructure Requirements and Layout Planning 3.3.1.4 Combination of Environments In areas with a combination of environments, place VAPs on the border between the different environment types slightly closer to the denser area. For example, in a cubical area with the outside wall having offices, simply locate the VAPs a little closer to the outside offices to provide coverage through the office walls. (See VAPs 11 and 13 in the floor plan map in section 3.4.3.). To ensure maximal coverage, VAPs can be re-located or added until coverage gaps are filled. 3.4 Planning VAP Layout The following section describes the steps of planning VAPs along the covered floor. At the end of this section an example of a planning map is provided. Note: It is highly recommended to use a floor plan when planning the VAPs locations. 3.4.1 RF Coverage Factors It is important to note the type of factors that can severely impact RF coverage, and should be avoided: • Metallic Structures such as elevators, high file cabinets, and some moveable metallic partitions severely degrade RF signals. All efforts should be made to locate VAPs in front of, or above metallic objects (desks, filing cabinets) to allow the signal to propagate. • Wall Materials such as concrete, tile, and cinderblock, as well as bathroom fixtures typically have fairly high signal attenuation and should be considered as dense spaces. • Types of Glass that have metallic coatings can affect RF coverage, typically exterior or mirrored. However this issue is not normally encountered inside a building. 3.4.2 Mapping Locations To Map the VAP Locations 1. Map out the available Ethernet jack locations and mark all CAT-5e/6 drop locations on the floor plan map. TIP: The size and number of the ceiling tiles can be used to measure distances. 2. Using the floor plan and the VAPs coverage guidelines (Provided in section 3.4.3), mark approximately where you would like to place each VAP in the facility. VAPs may be added or removed at anytime for optimal coverage. 3. For each jack being used to connect a VAP, check if the jack is already connected to the Ethernet switch. . 4. Connect the Ethernet cables corresponding to the selected jacks according to section 4.3. 5. It is also recommended to check the area where each VAP will be installed to ensure that the installation is feasible. Dual-Band MobileAccessVE Instant Coverage Solution User Manual 14 Infrastructure Requirements and Layout Planning 3.4.3 Optional Directional Antennas Each VAP has an integrated internal antenna that provides isotropic radiation. To prevent interference and improve coverage, connect directional antennas to VAPs installed near outer walls. The VAP antenna parameter must be set accordingly via the Web GUI. (See section 8.3). 3.4.4 Installation Plan Example The Following figure shows a floor plan map with all required marks: Figure 3-2. Floor Plan Example Notes: • The red VAP coverage circles have an approximate radius of 45, 60 and 70 foot (14, 18 and 21 meters) for the small, medium and large circles respectively. Diagram is drawn according to the guidelines for UMTS service, given in section 3.3.1. • VAP 3 is surrounded by the bathroom and stairwell, which are considered dense objects and would reduce coverage in that area by the other VAPs. • VAP 5 is an example of a unit that provides good coverage down the hallways in an Open Environment. • VAPs 11 and 13 are placed closer to the offices to provide better coverage to them, but on the open side will actually cover a much greater area. This is why the coverage is larger and shown here more as an oval than a circle. • The area between VAPs 7 and 14 would probably be the lowest coverage spot in the building because of the bathrooms and stairwell on either side. If after the system is installed, this area is still a little low on coverage, a VAP can be added, but it may also be covered by VAP 14. Dual-Band MobileAccessVE Instant Coverage Solution User Manual 15 Infrastructure Requirements and Layout Planning Note: The plan can be modified at any time by moving the units around or by adding units. The following figure depicts an actual measured quantified coverage of a floor area planned according to the above rules. Figure 3-3. Distributed VAPs propagation, 12dBm output power @ 1.8 GHz Dual-Band MobileAccessVE Instant Coverage Solution User Manual 16 VCU Unit Installation and Provisioning VCU Unit Installation and Provisioning This chapter describes the installation and basic configuration procedures for VE Control Units (VCU) located on each floor. In addition, this chapter describes the how to shift the relevant Ethernet connections required for the VAPs. These should be performed only after planning the floor coverage and installation locations, as described in the previous sections. 4.1 VCU Kit Contents The VE VCU Kit includes: Item Description Image Dual-Band VE Control Unit (VCU) Kit Note: The image shown here is only an example. The supplied unit may differ in connectors. Power Cord VE SW CD Local Configuration Cable (Crossed RJ-45 cable) Brackets for securing the VCU to a 19” rack (Shipped assembled to the VCU) Table 4-1: VCU Kit Dual-Band MobileAccessVE Instant Coverage Solution User Manual 17 VCU Unit Installation and Provisioning 4.2 VCU Physical Installation This section describes the physical installation and connections of the Master VCU, Slave VCUs, and the VAP Ethernet connections to the relevant VCUs. 4.2.1 Master VCU Installation The VE Control Unit can be installed as a Master VCU and control up to (12) Slave VCUs and/or VAPs and is installed in the main IDF/Telco closet. This section describes the Master VCU installation procedures. Note: When Master VCU only supports Slaves (no VAPs), the control units’ Ethernet Ports are not relevant and are not in use. 1. Install the Master VCU in the main IDF/Telco closet. The Master VCU can be installed in a rack, placed on a shelf, or secured using the supplied bracket. 2. Apply power to the Master VCU and verify that the PWR LED is lit. Also verify that the unit ACT LED completes initialization (blinking light) and shows a solid green light. 3. Connect (or request the service provider’s service personnel to connect) the provider’s signal source (Macrocell, Microcell, Picocell, or BDA etc.) to the Master VCU front panel RF ports (through passive interface). Power on the signal sources. Note 1: CELL/PCS Full-Band VCUs can be connected to the RF source through simplex or duplex connections. Note 2: Verify that the Master VCU source LED (See following figure) is GREEN, indicating an RF signal according to Max Expected Pin. If after connecting the capacity source, the LED remains RED, verify that the Max Expected Pin is configured properly and service is enabled. 4. To connect VCU Slaves to the Master VCU, connect the Master VCU VAP ports to the Slave VCUs VCU/VCH ports via the patch-panel that feeds the dedicated CAT-6/7 cabling system. VAP Status LEDs RF Ports* ACT LED VAP Ports 1-12 Figure 4-1. Master VCU Connections Dual-Band MobileAccessVE Instant Coverage Solution User Manual 18 VCU Unit Installation and Provisioning *NOTE: RF ports differ depending on the VCU model. For example, Full-Band CELL/PCS VCU models include QMA RF connectors supporting both simplex and duplex connections. 5. To connect Auxiliary alarms refer to section 4.2.1.1. Note: The connector is located on the controller rear panel. 6. According to VAPs layout plan (as explained in section 3.4.2) connect the Ethernet switch cables (See section 4.3 for a more detailed explanation). • If the requested jack is already in use, disconnect it from the Ethernet switch and reconnect it to the corresponding Ethernet port in the Slave VCU front panel. Note: After the Slave VCUs are connected (according to section 4.2.2) and the VAPs (according to chapter 5 ), verify that that the Master VCU VAP Status LEDs which correspond to the connected Slave VCUs and VAPs, complete initialization (blinking light) and show a solid green light. 4.2.1.1 Master VCU Alarm Output Connections Note: For Master/Slave VCU configuration, the Alarms are relevant only for the Master VCU. The controller can provide Major and Minor Output Alarms. These alarms can be connected directly to either the auxiliary input of the Base Station, or to any additional dry-contact application. The auxiliary connections are performed through the Master VCU rear panel Alarms port as shown below. Alarms Port for Auxiliary Connections Figure 4-2. Master VCU Alarms Connections A Major Alarm is generated when there is an alarm condition in one or more VCUs, while a Minor Alarm is generated when there is an alarm condition in one or more of the VAPs. Note: If only one alarm is required (Minor or Major) an external connection of a wire jumper between pins 8 and 13 is necessary (normally closed). Dual-Band MobileAccessVE Instant Coverage Solution User Manual 19 VCU Unit Installation and Provisioning Connect the relevant alarms according to the connector pinout: Major Alarm Minor Alarm Table 4-2. Alarms Connector – used pins 8 – Major Error Signal (Normally closed) 4.2.2 7 – Minor Error Signal (Normally open) 11 – Major COM 12 – Minor COM 15 –Major Error Signal (Normally open) 13 – Minor Error Signal (Normally closed) Slave VCUs Installation 1. Install the Slave VE Control Unit (VCU) in the IDF/Telco closet corresponding to the floor being covered. The Slave VCU can be installed in the rack using the supplied bracket in the IDF/Telco closet. Apply power to the Slave VCUs and note that the VCU PWR LED is lit. Note that the unit ACT LED completes initialization (solid light) and shows a blinking green light. (See Figure 4-3). PWR LED RF Source LEDs (One per Service) Master LED Figure 4-3. VCU PWR, RF and Master LEDs (Example above shows EGSM-UMTS unit) 2. Connect the Slave VCU front panel Master port to the Master VCU VAP port via the patch panel using dedicated CAT-6 cables. Verify that the Master LED completes initialization (blinking light) and shows a solid green light. The RF LEDs (of both services) should turn OFF. Dual-Band MobileAccessVE Instant Coverage Solution User Manual 20 VCU Unit Installation and Provisioning Figure 4-4. Master and Slave VCU Connections NOTE: When control unit functions as Master VCU the VCU VAP ports also serve as Slave VCU connection ports. 3. Connect the Slave VCU VAP ports to the patch-panel that feeds the existing structured CAT5e/6 cabling system. 4. According to VAPs layout plan (as explained in section 3.4.2), connect the Ethernet switch cables (See section 4.3 for more detailed explanation). • If the requested jack is already in use, disconnect it from the Ethernet switch and reconnect it to the corresponding Ethernet port in the Slave VCU front panel. Dual-Band MobileAccessVE Instant Coverage Solution User Manual 21 VCU Unit Installation and Provisioning 4.3 Ethernet Cable Connections to VAPS This section describes the how to perform the relevant Ethernet LAN connections to the VAPs from the VCUs via the Ethernet switch (See section 4.3.1) and provides a description of the PoE transferred between the VCU and the VAPs (See section 4.3.2). 4.3.1 Shifting Relevant Ethernet LAN Connections For VAPs installed on currently ACTIVE Ethernet ports, shift the relevant Ethernet LAN connections to the Ethernet ports on the Master or Slave VCU. Dual-Band MobileAccessVE Instant Coverage Solution User Manual 22 VCU Unit Installation and Provisioning For VAPs installed on currently INACTIVE Ethernet ports, connect as follows. Note: After the Slave VCUs are installed and connected to the correct ports in the patch panels, please proceed with the VAP installation as described in chapter 5 . However, it is recommended to complete the VCU provisioning first (See section 4.4) because when installing the VAPs they will instantly provide the wireless service (and the installer will be able to check the coverage). 4.3.2 Operation with LAN Utilizing Power over Ethernet (PoE) Power over Ethernet (PoE) is a technology that enables passing electrical power over the Ethernet cabling. Power can either come from a PoE-enabled Ethernet device (e.g. switch) or from a “mid-span” device built specifically for "injecting" power into the Ethernet cabling. PoE can operate over two different pairs in a CAT-5e/6 cable. These two methods are referred to as “alternative a” and ”alternative b”. All PoE compatible appliances, such as WLAN APs and IP Phones, support both alternatives and automatically detect and use the power on the appropriate pairs (alternative a or b). MobileAccessVE supports sharing LAN infrastructures that use either 802.3af PoE or 802.3at PoE. In the current release MobileAccessVE supports operation with “alternative a” PoE. Note: Future enhancements will support coexistence with “alternative b” PoE. If this is currently required, consult MobileAccess. Dual-Band MobileAccessVE Instant Coverage Solution User Manual 23 VCU Unit Installation and Provisioning 4.4 Provisioning the VE Control Unit This section describes how to set the basic parameters required for operation and remote management of the Master VCU using the Web GUI. The configuration dialogs are fully described in Chapter 6 . The Master or Slave mode is automatically detected according to the VCU's physical connection. If a connection to another VCU is detected, the VCU will be identified as a Slave, otherwise it will assume the role of a Master. Notes: 1. The initial configuration of the Master VCU is performed via local connection using a crosscable and connecting to VCUs default IP address. After performing the initial configuration and assigning the Master VCU an IP address, the system can be connected, monitored, and configured via a remote management connection. 2. The configuration and management of all of the system units (VCUs and VAPs) is performed via local or remote connection to the Master VCU unit. 4.4.1 Configure the Computer IP Parameters Configure the computer local LAN connection to operate in the same subnet as the default VCU IP address. Note that the procedure may vary slightly depending on the operating system installed on your computer. The following procedure is for Windows XP. To Configure the Computer’s IP Parameters: 1. Click the Start menu and choose Control Panel. 2. In the Control Panel, click Network and Internet Connections. 3. Click Network Connections and then double-click Local Area Connection. The Local Area Connections Properties dialog box appears with the General tab displayed by default. 4. In the Items list, select “Internet Protocol (TCP*IP)” and click the Properties button. 5. The “Internet Protocol (TCP/IP) Properties” dialog appears. Dual-Band MobileAccessVE Instant Coverage Solution User Manual 24 VCU Unit Installation and Provisioning Note: The Master VCU is supplied with the default IP address 192.168.1.1. • In order to communicate with the unit, it is necessary to assign your computer a Static IP address in the same subnet: 192.168.1.2 to 192.168.1.250. (i.e. 192.168.1.9 as shown in the example). • Define the subnet mask as shown: 255.255.255.0 6. Click OK. 7. The computer communication parameters are now defined and you can open a session to the Master VCU and provision the unit. 4.4.2 Provisioning the Master VCU Unit 1. Perform a local connection to the Master VCU unit by connecting the Master VCU front panel Management port and a laptop computer. 2. Open a web browser and type the Master VCU IP address in the address bar (Default: 192.168.1.1). Note: If you have forgotten the VCU IP address (or want to change it) it can be retrieved via the IP Recovery Tool application provided on the Setup CD. See section 9.2. Dual-Band MobileAccessVE Instant Coverage Solution User Manual 25 VCU Unit Installation and Provisioning The Login window appears. 3. Type the User Name “engineer” and enter the Password “eng”. The MobileAccessVE Web GUI appears. Main Menu Bar Network Topology Sub-tabs Corresponding to Selected Main Tab 4. To remotely access Master VCU via Ethernet, configure the VCU IP address as follows: • Choose the Management tab in the main menu bar • Click the IP Settings tab on the side bar. IP Settings Modify Button Dual-Band MobileAccessVE Instant Coverage Solution User Manual 26 VCU Unit Installation and Provisioning Note: See section 6.4 for a description of the Management tab. • Click the Modify button to define the STATIC IP Address according to existing LAN. • Set the Static IP address parameter (DHCP is not currently available) Default definitions: • The Default IP Address : 192.168.1.1 • The Default Subnet Mask: 255.255.255.0 • The Default Gateway: 192.168.1.254 • Click OK. 5. Log out and then log in again with the new IP settings. 6. Select the Config tab in the main menu bar. Note: See section 6.3 for a complete description of the Config tab. Dual-Band MobileAccessVE Instant Coverage Solution User Manual 27 VCU Unit Installation and Provisioning 7. The Master VCU appears in the Network Topology Tree as VCU-M. Select the Master VCU by clicking on it. Config Tab Master 8. Before configuring the Master VCU please give the unit an identifiable name. To assign the Master VCU an identifiable name: • Select the Module Info Tab and click the Modify button. Click Dual-Band MobileAccessVE Instant Coverage Solution User Manual 28 VCU Unit Installation and Provisioning • Type the unit name (up to 17 alpha-numeric characters) in the Controller Name dialog and click OK. 9. Uplink Cable Compensation – enable this parameter ONLY if the bonded cable lengths vary between the VCU and VAPs (reduces noise). It is NOT recommended to enable this option for similar cable lengths between the VCU and the connected VAPs. 10. Set the RF parameters for each connected service (up to two). Select the Service RF tab (Service1 RF / Service2 RF) of the service being configured (each service is configured through its’ corresponding tab): Modify Figure 4-5. Service RF Tab - Example Shows Service RF Tab for UMTS Service • For EGSM/DCS and EGSM/UMTS services (see figure above) - Click Modify and enter the DL central frequency for each service according to the following ranges: • EGSM: 925 – 960 MHz • UMTS: 2110 – 2170 MHz • DCS: 1805 – 1880 MHz Dual-Band MobileAccessVE Instant Coverage Solution User Manual 29 VCU Unit Installation and Provisioning • For CELL-PCS Full Band – Select BTS Connection (Simplex/Duplex). Figure 4-6: Service RF Tab – Example for CELL Full Band Note 1: CELL-PCS Full Band DL CF is Read Only. Note 2: The Service DL CF dialog displays the relevant range for each service. The figure above shows an example for the UMTS band. • Click OK. • Define Max expected power of BTS (0-33dBm). • Define UL system gain for each service (5 to -15dB). Notes: 1. Max expected Pin and Service CF parameters are service dependent and can be obtained from your service provider. Dual-Band MobileAccessVE Instant Coverage Solution User Manual 30 VCU Unit Installation and Provisioning 2. The remaining parameters are predefined to their default values. (Service Bandwidth is set to 15 MHz for EGSM, UMTS and CELL and to 20 MHz for DCS and PCS). 3. Any updates of the service Central Frequency definition is sent to all connected VAPs. 11. To verify proper operation of the system, refer to the Alarms sub-tab (in the Config tab). (See following figure). 12. Verify that all the alarms are GREEN. Refer to section 7.2 for alarm descriptions. Note: To briefly check the VCU status, click on the VCU name in the Topology Tree. The VCU icon will appear, showing the LEDs status. Master VCU Icon Dual-Band MobileAccessVE Instant Coverage Solution User Manual 31 VCU Unit Installation and Provisioning 13. Mask irrelevant alarm conditions to avoid having them reflected to the overall status of the unit. For Example If the Dual-Band system is currently only being used to provide one service, while the other service is disabled, the “Service Off” alarm can be masked (Disabled). In the example below, the left dialog shows the alarm response if the Service 2 alarm is NOT masked (enabled). In that case the Overall Status will be RED indicating a fault. If the Service 2 alarm is MASKED (Disabled), then the LED for the alarm will be RED; but, the Overall Status will be GREEN – showing NO Fault. Service2 Service Off Alarm Masked (Disabled) Service2 Service Off Alarm Unmasked (Enabled) Overall Status GREEN Overall Status RED Figure 4-7. Service2 Service Off Alarm – Not Masked Figure 4-8. Service2 Service Off Alarm –Masked In Figure 4-9, the alarm condition for “Service 2 Service Off” actually exists, while the masking prevents this condition from affecting the overall status of the system and therefore the Overall Status led below is green. 4.4.3 Provisioning the Slave VCUs Note: The Slave VCUs management and configuration is performed through a remote connection to the Master VCU, via the Web Management application. Before provisioning the Slave VCUs verify that the Master VCU unit, to which it is connected, has been provisioned (See section 4.4.1). The Slave VCU RF parameters are set via the Master VCU, therefore there is no need to configure the RF parameters individually for each connected Slave VCU. It is recommended to assign each Slave VCU an identifiable name. Dual-Band MobileAccessVE Instant Coverage Solution User Manual 32 VCU Unit Installation and Provisioning To assign a name to a Slave VCU: 1. Connect to the Master VCU unit (either locally as explained in section 4.4.1 or remotely) and select the Slave VCU to be provisioned from the Network Topology Tree. Selected Slave VCU- Each VCU has a default name of the form “VCUPx-name”, where: • Px - Master VCU port number to which the Slave VCU is connected • Name - User-defined name 2. To assign the Slave VCU an identifiable name: • Select the Module Info Tab • Click the Modify button • Type the unit name (up to 17 alpha-numeric characters) and click OK. 3. Uplink Cable Compensation – enable this parameter ONLY if the bonded cable lengths vary between the VCU and VAPs (reduces noise). It is NOT recommended to enable this option for similar cable lengths between the VCU and the connected VAPs. Dual-Band MobileAccessVE Instant Coverage Solution User Manual 33 VAP Installation and Provisioning VAP Installation and Provisioning This section provides a description of the VE Access Pods (VAPs) installation, verification, and monitoring procedures. 5.1 VAP Installation The VAPs installation procedure consists of connecting each VAP to an Ethernet jack in the appropriate location to provide optimal coverage (See sections 3.4 and 4.3). It is recommended to install the VAPs in places located high up so as to maximize the provided coverage per VAP. Note: Mounting a VAP beneath a desk or in another secluded location (e.g. office corner) decreases the effective coverage of the VAP increasing the need for a higher number of VAPs to cover the same area. There are three main types of VAP mounting installations: • Desk Mount – Used for VAPs mounted on locations such as desks, cubical walls, and filing cabinets. (See section 5.2.1.2). • Wall Mount – Used for VAPs mounted on walls (Recommended). (See section 5.2.1.3). • Ceiling Mount – Used for VAPs being installed in the ceiling. Two types of ceiling mount installations: • Horizontal – ONLY relevant for VAPs to which EXTERNAL antennas are connected. (See section 5.2.2). • Vertical – Applicable for VAPs working either with INTERNAL or EXTERNAL antennas. (See section 5.2.35.2.3). VAP Installation Considerations • Placing units in an open area. • Availability of CAT-5e/6 infrastructure. • The VAPs plug into standard (RJ-45) Ethernet connection jacks. • If the jack being used is already connected to Ethernet switch. For more information see sections 3.4.2 and 4.3. • Aesthetics of the VAP location. Dual-Band MobileAccessVE Instant Coverage Solution User Manual 34 VAP Installation and Provisioning 5.2 Desk and Wall Mount VAP Installations 5.2.1.1 VAP Kit Contents The Dual-Band VE Access Pod (VAP) Kit includes: Note: VAPs are provided with two mounting options: Desk Mount and Wall Mount Table 5-1: VAP Kit Kit Items Unit VE Access Pod (VAPs) Wall Mount Adaptor (Features double-sided sticky tape located on rear for fast installation) Front Rear – showing Desk Mount Adaptor (8) Screws: o (4) Short Screws – Used to secure adaptor to pod o (4) Long Screws – Used to secure wall mount adaptor to the wall (“anti-theft” installation) Long screws Short screws RJ-45 Jumper Cable Dual-Band MobileAccessVE Instant Coverage Solution User Manual 35 VAP Installation and Provisioning 5.2.1.2 Desk Mount Installation Note: All components (adaptor, screws, and cables) are included in the VAP Kit. • Place the VAP on the Desk Mount. • Secure the Desk Mount adaptor to the VE Access Pod using the (4) short screws. • Connect the RJ-45 jumper cable (CAT-5e/6) to the VAP’s RJ-45 connector. • Place the VAP on a flat surface according to the planned location. • Plug the other end of the cable into the VCUs (RJ-45) Ethernet jack. • When using an external antenna, connect the Ext. Antenna SMA connector(s) to the external antenna(s). This option must be SW configured via the web GUI. (Note: Internal antenna is enabled by default). Note: The maximum external antenna gain should not exceed 10 dBi. • Verify that the VAP receives power and connects to the VCU via the LEDs on the unit, both the GREEN LED and the BLUE LED should be lit. Assembly - Rear View Assembly - Front View Access Pod Activity – Blue LED Desk Mount Adaptor Ext. Antenna SMA Connectors Dual-Band MobileAccessVE Instant Coverage Solution User Manual Pwr – Green LED RJ-45 to VCU RJ-45 to LAN 36 VAP Installation and Provisioning 5.2.1.3 Wall Mount Installation Note: All components (adaptor, screws, and cables) are included in the VAP Kit. • Attach the VAP’s Wall Mount adaptor to the wall in the planned location, using the double sided sticky tape located on the rear or secure it using the longer screws. • Place the VAP on the Wall Mount. • Secure the Wall Mount adaptor to the VE Access Pod using the (4) short screws. • Connect the RJ-45 jumper cable via CAT-5e/6 to the VAP’s RJ-45 connector. • Plug the other end of the cable into the VCUs (RJ-45) Ethernet jack. • When using an external antenna, connect the Ext. Antenna SMA connector(s) to the external antenna(s). This option must be SW configured via the web GUI. (Note: Internal antenna is enabled by default). Note: The maximum external antenna gain should not exceed 10 dBi. • Verify that the VAP receives power and connects to the VCU via the LEDs on the unit, both the GREEN LED and the BLUE LED should be lit. Blue LED Green LED Access Pod Wall Mount Dual-Band MobileAccessVE Instant Coverage Solution User Manual Assembly 37 VAP Installation and Provisioning 5.2.2 Horizontal Ceiling Mount VAP Installations Note: This type of installation is ONLY relevant for VAPs to which EXTERNAL antennas are connected. The Horizontal installation procedure varies depending on the type of ceiling: • Lowered ceilings. • Concrete/Wood ceilings (See section 5.2.2.3). 5.2.2.1 VAP Kit Contents Please verify that the VAP Ceiling Mount Installation kit (P/N AK-VAP-CEILING-MT-H) includes the items listed below. Kit Items Description Unit Mounting Brackets “Twist on” Track Light Clip assembly Used for installation on lowered ceilings. A) Track Light Clip B) Screw, Bolt, and Washer (3) Flat Head Screws 100', 4/40 x 1/4 [NEROSTA] Used for assembling brackets (4) Self Screws 3dim L=8 ,Flat HD 90 [Steel zinc] A) Ceiling Bracket B) Locke Bracket Used for securing bracket assembly to VAP Dual-Band MobileAccessVE Instant Coverage Solution User Manual 38 VAP Installation and Provisioning 5.2.2.2 Lowered Ceiling Installation To Install VAP on a Lowered Ceiling 1. Loosely assemble the two brackets (Ceiling and Locke) using the provided Flat Head screws. The assembly will be secured at a later stage. 2. Assemble the Track Light Clip to the Ceiling Bracket (top side) using the provided washer and bolt. 3. Hook the assembly onto the VAP rear panel grid and fit to the bottom of VAP. 4. Secure the assembled brackets to the bottom of the VAP using the Self Screws. 5. Adjust the bracket assembly to firmly fit the VAP and tighten the three screws securing the assembly. 6. Mount the VAP on the lowered ceiling as follows: • Enlarge large flanges over opposite sides of T-bar. Note: Apply slight pressure as Twist Clip is made of spring steel. Dual-Band MobileAccessVE Instant Coverage Solution User Manual 39 VAP Installation and Provisioning • Twist flanges clockwise until small flanges snap over edges. The Twist Clip is now in position. • Place stud through 1/2" knock-out. Use washer-nut combination and tighten securely. 5.2.2.3 Concrete/Wood Ceiling Installation To Install VAP in Lowered Ceiling 1. Mark the location of the (4) screws on the ceiling according to the (4) larger holes on the bracket assembly. 2. Drill the screws in to the marked locations on the ceiling. 3. Align the (3) screw holes of each of the brackets (Ceiling and Locke) as shown in the adjacent figure and using the supplied Flat Head screws, loosely assemble the brackets. Note: To be adjusted at a later stage. Dual-Band MobileAccessVE Instant Coverage Solution User Manual 40 VAP Installation and Provisioning 4. Fit the assembled brackets on to the VAP by inserting the (5) hooks in corresponding top rear grid of the VAP and fit the other side on to the underside of the VAP. 5. Secure the assembled brackets to the bottom of the VAP using the Self Screws. 6. Adjust the bracket to the VAP and tighten the assembly screws. 7. Hang the VAP (using the (4) larger screw holes) on to the (4) screws located on the ceiling. Dual-Band MobileAccessVE Instant Coverage Solution User Manual 41 VAP Installation and Provisioning 5.2.3 Vertical Ceiling Mount VAP Installations Note: This type of installation option is applicable for VAPs working with either the INTERNAL antennas or the EXTERNAL antennas (internal antennas are designed to provide uniform coverage when aligned vertically on desk, wall or from ceiling). The Vertical installation procedure varies depending on the type of ceiling: • Lowered ceilings (See section 0). • Concrete/Wood ceilings (See section 5.2.3.3). 5.2.3.1 VAP Kit Contents Please verify that the VAP Ceiling Mount Installation kit (P/N AK-VAP-CEILING-MT-V) includes the items listed below. Kit Items Description Unit Mounting Brackets A) Ceiling Bracket B) Locke Bracket “Twist on” Track Light Clip Assembly (3) Flat Head Screws 100', 4/40 x ¼ [NEROSTA] A) Track Light Clip B) Screw, Bolt, and Washer Used for assembling brackets together (4) Self Screws 3dim L=8 ,Flat HD 90 [Steel zinc] Used for securing bracket assembly to VAP Dual-Band MobileAccessVE Instant Coverage Solution User Manual 42 VAP Installation and Provisioning 5.2.3.2 Lowered Ceiling Installation To Install VAP in Lowered Ceiling 1. Loosely assemble the (2) brackets using the provided Flat Head screws. (The assembly will be secured at a later stage.) 2. Assemble the Track Light Clip to the Large Horizontal Bracket (top side) using the provided washer and bolt. 3. Hook the assembly onto the VAP rear panel bottom grid and fit to underside of the VAP. 4. Secure the assembled brackets to the bottom of the VAP using the Self Screws. 5. Adjust the bracket to firmly fit the VAP and tighten the (3) bracket assembly screws. 6. Mount the VAP on the lowered ceiling as follows: • Enlarge large flanges over opposite sides of T-bar. Note: Apply slight pressure as Twist Clip is made of spring steel. Dual-Band MobileAccessVE Instant Coverage Solution User Manual 43 VAP Installation and Provisioning • Twist flanges clockwise until small flanges snap over edges. The Twist Clip is now in position. • Place stud through 1/2" knock-out. Use 4WN washer-nut combination and tighten securely. 5.2.3.3 Concrete/Wood Ceiling Installation To Install VAP in Lowered Ceiling 1. Mark the location of the (4) screws on the ceiling according to the (4) larger holes on the bracket assembly. 2. Drill the screws in to the marked locations on the ceiling. 3. Align the (3) screw holes of each of the brackets (Ceiling and Locke) as shown in the adjacent figure and using the Flat Head screws, loosely assemble the brackets. Note: To be adjusted at a later stage. 4. Fit the assembled brackets on to the VAP by inserting the (3) hooks in corresponding bottom rear grid of the VAP and fit the other side on to the underside of the VAP. 5. Secure to the underside of the VAP using the (4) supplied Self Screws. Dual-Band MobileAccessVE Instant Coverage Solution User Manual 44 VAP Installation and Provisioning 6. Tightly adjust the bracket to the VAP and secure the bracket assembly. 7. Hang the VAP on to the (4) screws located on the ceiling, and secure the screws. 8. Hang the VAP using the (4) larger screw holes on to the (4) screws located on the ceiling. 5.3 Verifying Coverage Verify coverage in the areas, adding and moving VAPs for optimal coverage according to the principles described in 3.3. Dual-Band MobileAccessVE Instant Coverage Solution User Manual 45 VAP Installation and Provisioning 5.4 Naming the VAPs, Verifying Connections, and Monitoring The VAPs are auto-discovered by the VCU and can be monitored via a remote or a local connection (to the Master VCU). The VAPs are auto-configured by the VCU without user intervention (no configuration procedure is required). However, if you wish, you may assign each VAP an identifiable name corresponding to its physical location. Note: See section 6 for full explanation about navigating the MobileAccessVE Web GUI application. 1. If a session in not already open to the MobileAccessVE Web management application, open a session to the Master VCU according to section 4.4.1. 2. Select a VAP from the Network Topology Tree. Each VAP has a default name of the form VAP Px-name where: • Px – Number of Slave VCU port to which the VAP is connected • Name - User-defined name 3. In the Network Topology Tree under the Control Unit, verify that a GREEN (or RED) circle is displayed for each connected VAP. Connected VAP • If a VAP is not green, select the VAP from the network topology tree. Then select the Config tab. Refer to the Alarms tab work area. The alarms for the selected VAP are displayed. Dual-Band MobileAccessVE Instant Coverage Solution User Manual 46 VAP Installation and Provisioning Note: VAP alarm mask is saved in the VCU, associated with the port to which the VAP is connected. In case you replace the VAP, the newly installed VAP will automatically be set with same alarm mask. 4. Refer to the Config Module info tab. 5. Assign each VAP a name as follows: Click Modify button to assign name • Click the Modify button • Type the unit name (up to 17 alpha-numeric characters) and click OK Dual-Band MobileAccessVE Instant Coverage Solution User Manual 47 VAP Installation and Provisioning 6. When required to transmit the RF signal through a connected external antenna: • Refer to the Service 1 RF and/or Service 2 RF tabs • Enable the External Antenna option Antenna option Note: If the external antenna option is not enabled, the signal will be transmitted via the integrated internal antenna, by default. 7. Verify the system connections according to the following section (See section 6 ). Dual-Band MobileAccessVE Instant Coverage Solution User Manual 48 Navigating the Web Access Application Navigating the Web Access Application The MobileAccessVE Web management application is accessed through any standard web browser connected to the Master VCU via a network within the same subnet as the Master VCU or a different subnet which is routable. 6.1 Opening a Session and Authentication Levels After the initial configuration (as explained in 4.4.1) the MobileAccessVE system can be accessed via the network. To Access the System: 1. Open a web browser. In the address bar type the Master VCU’s IP address as you set it in the Master VCU configuration operation (See section 4.4.1). 2. The Login pane appears. Enter your User Name and password. The following authentication levels are available: Level operator engineer Default Password oper eng admin ma98 Access This user has Read Only access. This user has access to basic configuration options. This user has Field Engineer permissions, in addition to access to changing passwords. Dual-Band MobileAccessVE Instant Coverage Solution User Manual 49 Navigating the Web Access Application 6.2 About the MobileAccessVE Web Access Window The MobileAccessVE Web window includes six main tabs that provide access to the applications’ main options. Here the Config tab is displayed by default. Note: The Monitor, Events, Setup, and Help tab are future options. The appearance of the each screen varies according to the tab displayed. The Main Menu Bar tabs are: • Config(uration) – Displayed by default upon login. Provides the selected units’ configuration parameters and alarms • Management - Provides upgrade, IP configuration and security options Both of these tabs are described in detail in the following sections Menu Bar Sub-tabs Corresponding to Menu Bar Options Dual-Band MobileAccessVE Instant Coverage Solution User Manual 50 Navigating the Web Access Application 6.3 Configuration Tab The Configuration tab provides the general information and service RF parameters for configuration of the units appearing in the Network Topology tree. To Access a VCU Configuration Tab On the left hand side of the window select a Master VCU/Slave VCU from the network topology tree. Select the Configuration tab from the menu-bar. The information and parameters displayed in the Configuration sub-tabs vary depending on whether a VCU or VAP is selected in the topology tree. The Configuration tab is divided in to three main areas: • Network Topology Tree – Displays the system units (Master VCU, Slave VCUs and VAPs) and their status. • Display Area – Displays the icon of the selected unit including the LED statuses. • Work Area – Displays the Module Info, alarms, and RF tabs corresponding to the unit selected in the topology tree (Master VCU, Slave VCU or VAP). Configuration Tab Selected VCU VCU Icon display Dual-Band MobileAccessVE Instant Coverage Solution User Manual 51 Navigating the Web Access Application 6.3.1 Network Topology Tree The Configuration Network Topology Tree appears on the left hand side when the Config tab is selected. Connected Slave VCUs and VAPs are automatically detected and displayed in the topology. The VE Web Access Application includes a Baseline feature providing an indication on network elements (VCUs/VAPs), which were disconnected from the VE network. Connected VCUs and VAPs are automatically added to the Baseline upon detection, and will appear in the topology as grayed out in case they are disconnected. The network elements are displayed in two levels: • First Level – Up to 12 VCUs • Second Level – Up to 12 VAPs connected to each VCU Note: The root is MobileAccessVE. Root Master VCU – First Level VAP – Second Level Disconnected Unit Each unit is assigned a Type Px-name: • Type – VCU-M, VCU or VAP (for Master VCU, Slave VCU or VE Access Pod) • Px - VCU port number • Name – User defined Each unit is displayed with a colored bullet that indicates its’ status: Color Green Red Gray Indicates OK Alarm Condition Disconnected unit (e.g. faulty connection). Generates RED Baseline alarm in Alarms tab (see 7.2). The root (the entire MobileAccessVE site) is also associated with a colored bullet that indicates the overall status of the deployment: Color Green Red Indicates OK Alarm Condition in one or more VCUs or VAPs Dual-Band MobileAccessVE Instant Coverage Solution User Manual 52 Navigating the Web Access Application 6.3.1.1 Removing Network Element from Baseline The Baseline automatically detects the connected units (VCUs and VAPs) and when for some reason a unit is disconnected or the connection with it is no longer detected it will not disappear from the topology but will appear in gray. In addition, the Baseline alarm in the Alarm tab will appear in Red. In order to remove a unit from the baseline so that it no longer appears in the network topology, it must be done via the GUI from either the Topology Tree or unit icon. To Remove a Unit from the Baseline 1. Click on the unit in the Topology Tree or on the unit icon (for example, VAP). The following dialog appears: 2. Click OK. The unit will no longer be displayed in the Network Topology Tree and the Baseline Alarm will show Green. Dual-Band MobileAccessVE Instant Coverage Solution User Manual 53 Navigating the Web Access Application 6.3.2 Configuration Display Area When selecting an element (Master VCU/Slave VCU or VAP) in the network topology tree, an icon representing the unit is displayed in the Configuration tab display area. Icon Display Area Dual-Band MobileAccessVE Instant Coverage Solution User Manual 54 Navigating the Web Access Application 6.4 Management Tab The Management tab provides user administrative management options and includes the submenu tabs: • Firmware – Used for upgrading/downgrading SW to VCUs. • Distribute – Used for distributing the upgrade/downgrade SW files to the VAPs. • Security – Used for changing user passwords. • SNMP Config – Used for defining the SNMP communities and trap destinations. • IP Settings – Used for viewing and modifying the network parameters. • Sys(tem) Log – N/A The following figure shows the Management screen with the menu options on left. Dual-Band MobileAccessVE Instant Coverage Solution User Manual 55 VCU Monitoring and Configuration VCU Monitoring and Configuration 7.1 Viewing VCU General Information The VCUs general information, such as unit name and SW versions, can be viewed in the Config Module Info sub-tab. To View VCU General Information • Click the Config tab from the main menu and select the VCU from the network topology tree. The Module Info sub-tab is displayed by default. The following information is displayed: Field Name Description User defined name for system element (up to 17 characters) Serial Number Factory set ID number Product Revision Revision number of VCU/VAP SW Active Version Version of the SW currently being used to manage and monitor the system SW Inactive Version Version of other system SW version not in use Restart VCU Button SW reset of the unit Uplink Cable Compensation Used to minimize interference that may be caused by bonded cables that vary in length Identify Enabling this option enables finding the physical location of the selected element (See section 10.1). When this option is set to ON, the LEDs on the corresponding VAP/VCU flickers. Dual-Band MobileAccessVE Instant Coverage Solution User Manual 56 VCU Monitoring and Configuration 7.2 Viewing VCU Alarms The alarms displayed in the Alarms tab correspond to the VCU (Master/Slave) selected in the topology tree. When a VCU element is selected in the topology tree, the Alarm tab displays the main alarms in the unit. To View VCU Alarms In the Topology Tree select the Control Unit (VCU) then click the Config(uration) tab in the menu bar located at the top of the window. Refer to the VCU Alarms and Mask sub tab. If one or more alarms occur, the corresponding Status indicator will be illuminated in RED. If the VCU is OK and no fault occurs, the Overall Status indicator will show GREEN. Alarm Description VCU Faulty RED - VCU fault. Remove and re-apply power to VCU. If problem persists, replace VCU. Over Temperature Temperature of unit exceeds normal range. Mismatch Red – Mismatch of services (e.g. CELL/PCS VAP connected to EGSM/UMTS VCU, VCU connected to slave VCU etc.). Service 1 DL RF Pwr Low RED - DL RF Power is lower by 15dBm (or more) from the Max Expected Pin. Service 1 DL RF Pwr High RED - the input power exceeds the maximum expected Pin by more than 3 dB. Service 1 Service Off User has disabled Service 1. Dual-Band MobileAccessVE Instant Coverage Solution User Manual 57 VCU Monitoring and Configuration 7.3 Alarm Description Service 2 DL RF Pwr Low RED - DL RF Power is lower by 15dB (or more) from the Max Expected Pin. Service 2 DL RF Pwr High RED - the input power exceeds the maximum expected Pin by more than 3 dB. Service 2 Service Off User has disabled Service 2. VCUs in Baseline RED – Communication lost with VCU defined in baseline VAPs in Baseline RED - Communication lost with VAP defined in baseline Overall Status Indicates Fault (RED) level or GREEN if there are no faults. Master VCU RF Parameters Note: The RF parameters are not displayed for control units functioning as Slave VCUs. To Access the Service RF Tab Click the Config tab from the main menu bar and then select the Master control unit from the network topology and click the Service RF tab. The parameters displayed in Service RF tabs correspond to the selected element. Figure 7-1. Service RF Tab for UMTS Service (similar for EGSM and DCS) Dual-Band MobileAccessVE Instant Coverage Solution User Manual 58 VCU Monitoring and Configuration Figure 7-2. Service RF Tab for CELL/PCS The following table provides a description of the RF parameters displayed in the Service RF tabs. Parameter Description Type Set (read only) according to unit type (e.g. EGSM / UMTS) BTS Connection* Type of BTS RF connection (Simplex/Duplex) DL Center frequency (from BTS): DL CF • **For EGSM/DCS/UMTS - User defined, according to connected service • For CELL/PCS – Read Only UL CF UL center frequency (from BTS) – corresponding to defined DL Center Frequency. Automatically assigned by the system according to the DL frequency Max Exp Pin** Maximum expected input power from the BTS. Used for adjustment procedure. Range: 0-33 dBm. User defined. Pin Actual measured Pin (read only) UL System Gain Used for adjusting the UL system gain. Range: -15dB to +5dB Service Control Enables (On)/Disables (Off) the service * Appears in CELL/PCS Full Band GUI only. ** Required parameters to be provisioned by the user. Dual-Band MobileAccessVE Instant Coverage Solution User Manual 59 VAP Monitoring and Configuration VAP Monitoring and Configuration 8.1 Viewing VAP General Information The VAPs general information, such as unit name and SW versions, can be viewed in the Config Module Info sub-tab. To View VAP General Information Click the Config tab in the main menu and select the VAP from the network topology tree. The Module Info sub-tab will be displayed by default. The following information is displayed: Field Name Serial Number Product Revision SW Active Version SW Inactive Version Restart VAP Button Identify Button Description User defined name for system element (up to 17 characters) Factory set ID number Revision number of VCU/VAP Version of the SW currently being used to manage and monitor the system Version of other system SW version not in use SW reset of the unit Enabling this option enables finding the physical location of the selected element (See section 10.1). When this option is set to ON, the LEDs on the corresponding Access POD/VCU flickers. Dual-Band MobileAccessVE Instant Coverage Solution User Manual 60 VAP Monitoring and Configuration Note: VAP Name is saved in the VCU associated to the port to which the VAP is connected, such that in case you replace a VAP, the new one will be associated with the same name. In case you do not want to keep the configuration of the replaced VAP, remove it from the topology baseline before connecting the new VAP. 8.2 Viewing VAP Alarms When a VAP element is selected in the topology tree, the Alarm tab displays the main alarms in the unit. To Access VAP Alarms Tab Click the Config tab in the main menu and select the VAP from the network topology tree. Select the VAP Alarms sub tab. If one or more alarms occur, the corresponding Status indicator will be illuminated in RED. If the VAP is OK and no fault occurs, the Overall Status indicator will show GREEN. Alarm Description Service 1/2 Off User has disabled the service DL Adjustment Cable (between VCU to VAP) is too long (over 100m/300ft) VAP Faulty A fault has been detected in the VAP Overall Temperature Temperature of unit exceeds normal range Overall Status Indicates Fault (RED) level or GREEN if there are no faults Dual-Band MobileAccessVE Instant Coverage Solution User Manual 61 VAP Monitoring and Configuration Note: DL adjustment alarm is raised when a VAP is connected over a cable exceeding system cable length limitation. In such cases, the system continues to provide the wireless services, but you should check the coverage of the VAP (as output power may be degraded due to excess cable loss) and check the Ethernet connection (as Ethernet standard maximum cable length has probably been exceeded). 8.3 VAP RF Parameters The Service1 and Service2 tabs provide the configurable RF parameters corresponding to the VAP element selected in the network topology tree. Up to two service RF tabs are displayed, one for each service. The displayed RF parameters are similar for both service tabs. To View the VAP RF Parameters Click the Config tab from the main menu bar and then select the VAP from the network topology and click the Service RF tab. The parameters displayed in Service RF tabs correspond to the selected element. Selected VAP Dual-Band MobileAccessVE Instant Coverage Solution User Manual 62 VAP Monitoring and Configuration The following table provides a description of the RF parameters displayed in the Service RF tabs. Parameter Type Service Control DL Pout Level DL Pout Antenna Description Set according to unit type (e.g. EGSM /UMTS) Used to Disable (Off) or Enable (On) the service for the specific VAP Normal – Pout from the VAP at normal level (according to the service) Low – Pout from VAP is attenuated by 5 dB Presents the measured output power Select External only if an external antenna is connected to this VAP. Otherwise, the option should be set to Internal (default) Note: VAP RF settings (Service Control, DL Pout Level, Antenna) are saved in the VCU associated to the port to which the VAP is connected, such that in case you replace a VAP all parameters are automatically set to the new VAP. In case you do not want to keep the configuration of the replaced VAP, remove it from the topology baseline before connecting the new VAP. Dual-Band MobileAccessVE Instant Coverage Solution User Manual 63 Administrative Operations Administrative Operations This chapter describes the following Administrative operations: • Changing a password • IP configuration parameters • SNMP Configuration parameters • Unit software upgrade and software management procedures 9.1 Changing Password The Management - Security tab provides password change options. To Set the Application Password or Change an Existing Password 1. Select the Security option of the Management tab at the top of the window. 2. Click the Modify button beside the User Name whose password is being modified. 3. Enter the New Password and re-enter in the Confirm New Password field. 4. Click OK. Note: Passwords can only be changed when connected as an administrator. Dual-Band MobileAccessVE Instant Coverage Solution User Manual 64 Administrative Operations 9.2 Retrieving VCU IP Address The IP Recovery Tool enables viewing and/or changing the VCU IP address. To Install IP Recovery Tool 1. Install the IP Recovery Tool application, which is provided by MobileAccess on the Setup CD, on the computer to which the VCU is to be connected. 2. Double-click on the Recovery Tool Setup and follow the prompts – standard installation procedure. To Retrieve the VCU IP Address 1. Connect the computer, on which the Recovery Tool is installed, to the VCU RS-232 Console port located on the rear panel (See section 1.3.1.2). 2. Run the IP Recovery Tool application from the computer Start menu. The Connection dialog appears. 3. Select the Comm. Port corresponding to the connection on the computer. 4. Enter the password Eng and click Connect. Dual-Band MobileAccessVE Instant Coverage Solution User Manual 65 Administrative Operations The current IP parameters dialog appears showing the VCI IP address. 5. To modify the current IP Parameters: click Change. The Change IP Parameters dialog appears: Enter the new parameter value and click OK and Exit. Dual-Band MobileAccessVE Instant Coverage Solution User Manual 66 Administrative Operations 9.3 IP Settings The IP Settings tab is used for viewing and modifying the network parameters. The default parameter settings are as follows: • IP Address: 192.168.1.1 • Subnet Mask: 255.255.255.0 • Default Gateway: 192.168.1.254 Click Modify button to change settings Dual-Band MobileAccessVE Instant Coverage Solution User Manual 67 Administrative Operations 9.4 SNMP Configuration Parameters The SNMP Config tab is used for defining the SNMP communities in which the devices and management station belongs and to where the traps are sent. The SNMP default communities are: • Read - public • Write - private • The Community Names can be modified by clicking the Modify button in the SNMP Configuration display area. • Additional Trap Destinations can be added by clicking the Add New button in the Trap Destination List display area: Dual-Band MobileAccessVE Instant Coverage Solution User Manual 68 Administrative Operations 9.5 Upgrading (or Downgrading) VCU and VAP Software Note: Before you start, verify that the VCU and VAPs upgrade files are located in an accessible location (i.e. on your computer). The software for each VCU and its hosted VAPs can be upgraded through access to the VCU, where the VAPs must be upgraded first and only then the VCU. Note: In installations with Slave VCUs, a session should be opened to the IP address of the Slave VCU in order to upgrade the SW of the Slave VCU and associated VAPs. Two types of files are stored on the VCU and on individual VAPs: Active software on which the unit operates, and Standby software. The Active and Standby software can be swapped on each individual unit. In addition, the VCU holds two software images for VAPs to be used in download process to VAPs. The upgrade procedure consists of the following main phases: 1. Uploading the new VCU and VAP software to the host VCU. 2. Setting the new software as the Active software. 3. Downloading the new software to selected VAPs and activating it as the Active software on those VAPs. 4. Activating the new VCU software on the VCU. The procedure is performed via two screens: • Distribute Screen – Used to download the VAP software version to selected VAPs. • Firmware Screen – Used to manage the software files stored on the VCU. Dual-Band MobileAccessVE Instant Coverage Solution User Manual 69 Administrative Operations 9.5.1 Upgrading the VAP SW To Upgrade the VAPs SW Version: 1. Upload the VAP upgrade files from your storage location to the VCU as follows: • Click the Management menu tab and then select the Firmware sub-menu option located on the left side. • In the Load New Firmware display area, click the Browse button. • Browse for the file to be loaded from your computer location. The Download button appears and the progress bar will show the download status. Load New Firmware Display Area • After the download is complete, the downloaded SW version will appear in the Standby Bank column of the VAP display area. Notes: 1. Locate the Firmware files on your local hard-drive prior to the download process. 2. During the download process DO NOT disconnect the Web GUI connection to the VCU. 2. To distribute the new software to selected VAPs: • Select the Distribute sub-menu option found on the left side. Dual-Band MobileAccessVE Instant Coverage Solution User Manual 70 Administrative Operations Management Tab Distribute Sub-tab 3. Download the new version to the selected VAPs (Note: The downloaded version is stored as Inactive in the VAPs until a Swap procedure is performed.) • In the VAP Distribute Table display area, checkmark the VAPs to be upgraded. The Active and Inactive SW versions for each VAP are listed in the relevant columns. • Click the Distribute button to download the new software to the selected VAPs. The software is stored as the Inactive version in the VAPs. • Set the new software as the Active version in the selected VAPs by clicking the Swap button. • The VAP upgrade procedure is complete. Notes: 1. As during the distribution process service may be interrupted, it is advised to perform the SW download and distribution in a maintenance window scheduled at off-peak hours (e.g. nights and/or weekends). 2. During the distribution process DO NOT perform configuration changes, connect or disconnect VAPs, and/or disconnect the web GUI. 3. After the distribution process is complete and swapping between VAP SW images, the VCU will restart automatically. After restart, the VAP firmware distribution table will be empty. Within several seconds it will re-populate as the VCU re-discovers connected VAPs. Dual-Band MobileAccessVE Instant Coverage Solution User Manual 71 Administrative Operations 9.5.2 Upgrading the VCU SW To Upgrade the VCU SW Version: 1. Upload the VCU upgrade files from your storage location to the VCU as follows: • Click the Management menu tab and then select the Firmware sub-menu option found on the left side. Firmware Sub-tab Management Tab • In the Load New Firmware display area, click the Browse button. • Select the file to be loaded from your computer location. The Download button appears and the progress bar will show the download status. • After the download is complete the downloaded SW version will appear in the Standby Bank column of the VCU display area. 2. Define the downloaded version as the Active version (to be used for upgrade) as follows: • In the VCU display area, click Swap. The downloaded version appears in the Active Bank column and the Controller is automatically restarted. • The VCU Upgrade procedure is complete. Dual-Band MobileAccessVE Instant Coverage Solution User Manual 72 Troubleshooting 10 Troubleshooting 10.1 Finding a Specific VAP in the Building It is recommended to assign each VAP an identifiable name corresponding to its physical location, as explained in section 5.4. If a name was not configured, or for some other reason a specific VAP cannot be physically located, identify the VAP according to the instructions in the following example. To Locate a VAP 1. Select the Config tab from the main menu bar and then select the VAP to be located from the topology tree. Selected VAP Module Info 2. Click the Module Info sub-tab. Dual-Band MobileAccessVE Instant Coverage Solution User Manual Identify On/Off 73 Troubleshooting 3. Set Identify to ON. The Activity LED (Blue) on the corresponding Access Pod will start blinking fast. (You will need to physically locate the VAP to see the blinking LED). Blue LED (Activity) Green LED (PWR) 4. Locate the Access Pod. 5. It is advisable to assign it an identifiable name via the Access Pod Module Info tab, as described in section 5.4 (e.g. floor 3, room 2) and set the Identify field to Off again. Dual-Band MobileAccessVE Instant Coverage Solution User Manual 74 Troubleshooting 10.2 Wireless Service is Not Available 1. Verify that the Master VCU is connected to the BTS, powered up, and configured. 2. Verify that the Max Expected Power setting is correct by either: • Viewing the actual VCU Power Measurement (DL Pin) in the VCU Service RF tab (See below). Config Tab DL Pin • Measuring the actual BTS output using a Spectrum Analyzer. 3. Verify correct settings of Frequencies and UL Gain (See DL/UL CF and UL System Gain parameters in Service RF sub-tab displayed above). 4. Verify that the RF cables are properly connected to the VCU. 5. View the VCU Alarms (above image) and verify that the VCU is working properly. 10.3 PoE is Not Working Verify that the PoE used is “alternative a”. The MobileAccessVE system currently only supports this alternative. Verify that all pairs are wired in the patch panels and jumper cords. Note: Future enhancements will support “alternative b”. Consult MobileAccess if you currently require support for “alternative b.” Dual-Band MobileAccessVE Instant Coverage Solution User Manual 75 Troubleshooting 10.4 Ethernet Service is Degraded Ethernet standards specify that 100m (300ft) is the maximum distance between an Ethernet switch and appliance (computer, WLAN AP, etc). This is relevant when MobileAccessVE shares the IT LAN. The distance includes all patch cords (from switch to VCU, from VCU to patch panel, from RJ-45 outlet to VAP, and from VAP to appliance). 1. Review the IT documentation, which may be available from your IT department, to determine cable types and lengths. 2. Check the lengths of the patch cords being used and verify the end-to-end distance does not exceed 100m (300ft). 3. A Fluke cable tester can be used to measure cable length. 10.5 No Service from Connected Access Pod This requires physically accessing the Access Pod to check the LEDs, and accessing the Access Pod through the Web GUI to verify the Access Pod configuration. 1. Physically view the Access Pod and confirm that both LEDs on the Access Pod are lit: • Power LED (Green) is OFF – Either no connectivity to the VCU or the VAP is faulty. Try replacing the VAP. Try connecting the VAP directly to the VCU if the Power LED is lit check the cable and the patch cords. • Activity LED is constantly blinking – The Access Pod cannot initialize due to exceeded cable length. Try using the closest free RJ-45 jack fed with a different cable. Blue LED (Activity) Green LED (PWR) 2. Check other Access Pods connected to the same VCU. 3. Verify that the VAP configuration as follows: • Connect to the VCU using the MobileAccessVE Web GUI application (See section 6.1) and select the VAP from the topology tree. Dual-Band MobileAccessVE Instant Coverage Solution User Manual 76 Troubleshooting Config Tab Selected VAP • In the Config tab, click on the relevant Service RF sub-tab and verify that the Service Control parameter is set to On. • Confirm that the VCU port is functioning (VAP status LED associated with this Pod is green). • In case external antennas are connected – verify the VAP was configured to use the external antennas (See Antenna parameter in VAP Service RF sub-tab, shown above). Dual-Band MobileAccessVE Instant Coverage Solution User Manual 77 Troubleshooting 10.6 VCU Cannot be Monitored via SNMP VE traps are not received by the external Fault Monitoring system. 1. Verify that the VCU is powered ON. 2. Verify that the SNMP traps destination address is configured correctly. 3. Verify the IP connectivity to the Fault Monitoring server using “ping.” 4. Verify that SNMP port is not blocked or fire-walled in the IP network. 5. Initiate an Alarm and confirm the trap is received by external Fault Monitoring server. For example: • Access the VAP Service RF sub-tab (See section 8.3). Service Control • Verify that the alarm is unmasked. • Set the Service Control parameter to Off. • Confirm the trap is received by external Fault Monitoring server. Dual-Band MobileAccessVE Instant Coverage Solution User Manual 78 Appendix A - Traps This section lists the MobileAccessVE Dual-Band Controller and Access Pod Traps. VE Control Unit (VCU) Traps Trap Name Trap Description vcuChannel_1_DLPowerLow (Major) Alert for low RF in VCU for Service 1: 15dB less than max expected power vcuChannel_1_DLPowerHigh (Minor) Alert for High RF in VCU for Service 1: 3dB more than max expected power vcuChannel_1_ServiceOff (Major) User set Service 1 to off vcuChannel_2_DLPowerLow (Major) Alert for low RF in VCU for Service 2: 15dB less than max expected power vcuChannel_2_DLPowerHigh (Minor) Alert for High RF in VCU for Service 2: 3dB more than max expected power vcuChannel_2_ServiceOff (Major) User set Service 2 to off vcuFault (Major) HW failure in VCU vcuOverTemperature (Minor) VCU temperature is too high vcuMismatchType (Minor) When VCU services types is different than VAP services types vcuAdjustment (Major) When adjustment (for Slave VCU) has failed (cable too long) VE Access Pod (VAP) Traps Trap Name Trap Description vapAdjustment (Major) Cable is too long (over 100m/300ft) vapChannel_1_ServiceOff (Minor) User set service 1 to Off vapChannel_2_ServiceOff (Minor) User set service 2 to Off vapFaulty (Major) The Access Pod is faulty vapOverTemperature (Minor) VAP temperature is too high Dual-Band MobileAccessVE Instant Coverage Solution User Manual 79 Appendix B – MobileAccess VE Dual Band MIB Tree Structure (Version 1.8) Appendix B – MobileAccess VE Dual Band MIB Tree Structure (Version 1.8) The following MIB is used for managing the MobileAccess VE VCU and VAPs across the network infrastructure. This MIB Structure and OIDs are specifically related to MIB Release 1.8 with the expectation that New OIDs will be added with the release of future Firmware Versions. MIB Tree Structure is on the following pages. Dual-Band MobileAccessVE Instant Coverage Solution User Manual 80 Appendix B – MobileAccess VE Dual Band MIB Tree Structure (Version 1.8) Dual-Band MobileAccessVE Instant Coverage Solution User Manual 81 Appendix B – MobileAccess VE Dual Band MIB Tree Structure (Version 1.8) Dual-Band MobileAccessVE Instant Coverage Solution User Manual 82 Appendix B – MobileAccess VE Dual Band MIB Tree Structure (Version 1.8) MobileAccess Version 1.8 MIBs/OID Descriptions Module Node Name OID String Description MaVEMIB enterprises .1.3.6.1.4.1 Enterprise MaVEMIB mobileAccess .1.3.6.1.4.1.15921 MobileAccess MaVEMIB maVE .1.3.6.1.4.1.15921.11 MobileAccess VE MaVEMIB maVEVCU .1.3.6.1.4.1.15921.11.1 MobileAccess VE VCU MaVEMIB maVEVCUTable .1.3.6.1.4.1.15921.11.1.1 VCU Table MaVEMIB maVEVCUEntry .1.3.6.1.4.1.15921.11.1.1.1 VCU Table Entries MaVEMIB vcuLocationLevelIndex1 .1.3.6.1.4.1.15921.11.1.1.1.1 1 for Master VCU and 2 to 13 are the Slave VCUs MaVEMIB vcuName .1.3.6.1.4.1.15921.11.1.1.1.2 MA VCU NAME MaVEMIB vcuSerialNumber .1.3.6.1.4.1.15921.11.1.1.1.3 MA VCU Serial Number MaVEMIB vcuProductRevision .1.3.6.1.4.1.15921.11.1.1.1.4 MA VCU Product revision MaVEMIB vcuSWVersionActive .1.3.6.1.4.1.15921.11.1.1.1.5 MA VCU Active Software Version MaVEMIB vcuSWVersionInactive .1.3.6.1.4.1.15921.11.1.1.1.6 MA VCU Inactive Software Version MaVEMIB vcuReset .1.3.6.1.4.1.15921.11.1.1.1.7 MA VCU RESET MaVEMIB vcuIdentify .1.3.6.1.4.1.15921.11.1.1.1.8 MA VCU Indetify MaVEMIB vcuChannel1ServiceType .1.3.6.1.4.1.15921.11.1.1.1.9 MA VCU Service Type MaVEMIB vcuChannel1DLCF .1.3.6.1.4.1.15921.11.1.1.1.10 MA VCU First channel DL CF in 100Khz MaVEMIB vcuChannel1ULCF .1.3.6.1.4.1.15921.11.1.1.1.11 MA VCU First channel UL CF in 100Khz .1.3.6.1.4.1.15921.11.1.1.1.12 MA VCU First channel Max Expected Input Power - in dBm ;when vcuChannel1ServiceType >50(In WiMAX/PHS)the value is (dBm value + 100)) MaVEMIB vcuChannel1MaxExpectedPin Dual-Band MobileAccessVE Instant Coverage Solution User Manual 83 Appendix B – MobileAccess VE Dual Band MIB Tree Structure (Version 1.8) Module Node Name OID String Description MaVEMIB vcuChannel1ActualPin .1.3.6.1.4.1.15921.11.1.1.1.13 MA VCU First channel Actual Input Power In - in 0.1 dBm means: (when vcuChannel1ServiceType <50 the value is (dBm value *10) ; when vcuChannel1ServiceType >50(In WiMAX/PHS) the value is (dBm value + 100)*10 MaVEMIB vcuChannel1ULSystemGain .1.3.6.1.4.1.15921.11.1.1.1.14 MA VCU First channel UL System Gain MaVEMIB vcuChannel1ServiceControl .1.3.6.1.4.1.15921.11.1.1.1.15 MA VCU First channel Service control (N/A in MIMO/SISO services) MaVEMIB vcuChannel2ServiceType .1.3.6.1.4.1.15921.11.1.1.1.16 MA VCU Service Type MaVEMIB vcuChannel2DLCF .1.3.6.1.4.1.15921.11.1.1.1.17 MA VCU Second channel DL CF in 100Khz (in MIMO refer to relevant leaf at channel 1) MaVEMIB vcuChannel2ULCF .1.3.6.1.4.1.15921.11.1.1.1.18 MA VCU Second channel UL CF in 100Khz (in MIMO refer to relevant leaf at channel 1) MaVEMIB vcuChannel2MaxExpectedPin .1.3.6.1.4.1.15921.11.1.1.1.19 MA VCU Second channel Max Expected Input Power - in dBm (in MIMO refer to relevant leaf at channel 1) MaVEMIB vcuChannel2ActualPin .1.3.6.1.4.1.15921.11.1.1.1.20 MA VCU Second channel Actual Input Power - in 0.1 dBm means: (when vcuChannel2ServiceType <50 the value is (dBm value *10) ; when vcuChannel2ServiceType >50 the value is (dBm value + 100)*10 MaVEMIB vcuChannel2ULSystemGain .1.3.6.1.4.1.15921.11.1.1.1.21 MA VCU Second channel UL System Gain (in MIMO refer to relevant leaf at channel 1) MaVEMIB vcuChannel2ServiceControl .1.3.6.1.4.1.15921.11.1.1.1.22 MA VCU Second channel Service control (N/A in MIMO/SISO services) MaVEMIB vcuServiceMode .1.3.6.1.4.1.15921.11.1.1.1.23 MA VCU Service mode ; set is relevant for values of MIMO/SISO/OFF .1.3.6.1.4.1.15921.11.1.1.1.24 MA VCU Alarms; Bits are as follow: vcuChannel1ServiceType <50: 1 - VCU Faulty; 2 - Over Temperature; 4 - Type Mismatch; 8 - Channel1 RF DL low; 16 Channel1 RF DL High; 32 - Channel1 RF Off; 64 - Channel2 RF DL low; 128 - Channel2 RF DL High; 256 - Channel2 Off ; vcuChannel1ServiceType >50: 1 - VCU Faulty; 2 - Over Temperature; 4 - Type Mismatch; 8 - service Off; 16 - Channel1 RF DL low; 32 - Channel1 RF DL High; ; 64 Channel2 RF DL low; 128 - Channel2 RF DL High; 256 - Channel2 Off MaVEMIB vcuAlarms Dual-Band MobileAccessVE Instant Coverage Solution User Manual 84 Appendix B – MobileAccess VE Dual Band MIB Tree Structure (Version 1.8) Module Node Name OID String Description MaVEMIB vcuAlarmMask .1.3.6.1.4.1.15921.11.1.1.1.25 MA VCU Alarm Mask; Bits refer to alarms bits described above MaVEMIB vcuOverallStatus .1.3.6.1.4.1.15921.11.1.1.1.26 MA VCU Overall Status MaVEMIB vcuMACaddress .1.3.6.1.4.1.15921.11.1.1.1.27 MA VCU MAC Address MaVEMIB vcuIPAddress .1.3.6.1.4.1.15921.11.1.1.1.28 MA VCU IP Address MaVEMIB vcuSubnetMask .1.3.6.1.4.1.15921.11.1.1.1.29 MA VCU Subnet Mask MaVEMIB vcuDefaultGateway .1.3.6.1.4.1.15921.11.1.1.1.30 MA VCU Default Gateway MaVEMIB vcuTrapDestinationIP1 .1.3.6.1.4.1.15921.11.1.1.1.31 MA VCU Trap Destination Ip address 1 MaVEMIB vcuTrapDestinationIP2 .1.3.6.1.4.1.15921.11.1.1.1.32 MA VCU Trap Destination Ip address 2 MaVEMIB vcuTrapDestinationIP3 .1.3.6.1.4.1.15921.11.1.1.1.33 MA VCU Trap Destination Ip address 3 MaVEMIB maVEVAP .1.3.6.1.4.1.15921.11.2 MobileAccess VE VAP MaVEMIB maVEVAPTable .1.3.6.1.4.1.15921.11.2.1 VAP Table MaVEMIB maVEVAPEntry .1.3.6.1.4.1.15921.11.2.1.1 VAP Table Entries MaVEMIB vapLocationLevelIndex1 .1.3.6.1.4.1.15921.11.2.1.1.1 1 to 12 the VAP port itself (single tier), or 2 to 13 for the Slave VCU port index MaVEMIB vapLocationLevelIndex2 .1.3.6.1.4.1.15921.11.2.1.1.2 MaVEMIB vapName .1.3.6.1.4.1.15921.11.2.1.1.3 MA VAP NAME MaVEMIB vapSerialNumber .1.3.6.1.4.1.15921.11.2.1.1.4 MA VAP Serial Number MaVEMIB vapProductRevision .1.3.6.1.4.1.15921.11.2.1.1.5 MA VAP Product revision MaVEMIB vapSWVersionActive .1.3.6.1.4.1.15921.11.2.1.1.6 MA VAP Active Software Version MaVEMIB vapSWVersionInactive .1.3.6.1.4.1.15921.11.2.1.1.7 MA VAP Inactive Software Version MaVEMIB vapReset .1.3.6.1.4.1.15921.11.2.1.1.8 MA VAP RESET Dual-Band MobileAccessVE Instant Coverage Solution User Manual 1 to 12 - for the VAP port index 85 Appendix B – MobileAccess VE Dual Band MIB Tree Structure (Version 1.8) Module Node Name OID String Description MaVEMIB vapIdentify .1.3.6.1.4.1.15921.11.2.1.1.9 MA VAP Indetify MaVEMIB vapChannel1ServiceType .1.3.6.1.4.1.15921.11.2.1.1.10 MA VAP Service Type MaVEMIB vapChannel1ServiceControl .1.3.6.1.4.1.15921.11.2.1.1.11 MA VAP First channel Service control (N/A in WiMAX) MaVEMIB vapChannel1DLPoutLevel .1.3.6.1.4.1.15921.11.2.1.1.12 MA VAP first channel DL output attenuation Level MaVEMIB vapChannel1DLPoutActual .1.3.6.1.4.1.15921.11.2.1.1.13 MA VAP First channel DL Actual Output Power - in 0.1 dBm means: (when vapChannel1ServiceType <50 the value is (dBm value *10) ; when vapChannel1ServiceType >50 the value is (dBm value + 100)*10 MaVEMIB vapChannel1AntennaType .1.3.6.1.4.1.15921.11.2.1.1.14 MA VAP First channel Antenna Type internal - external MaVEMIB vapChannel2ServiceType .1.3.6.1.4.1.15921.11.2.1.1.15 MA VAP Service Type MaVEMIB vapChannel2ServiceControl .1.3.6.1.4.1.15921.11.2.1.1.16 MA VAP Second Band Service control(N/A in MIMO/SISO) MaVEMIB vapChannel2DLPoutLevel .1.3.6.1.4.1.15921.11.2.1.1.17 MA VAP Second channel DL output attenuation Level MaVEMIB vapChannel2DLPoutActual .1.3.6.1.4.1.15921.11.2.1.1.18 MA VAP Second channel DL Actual Output Power - in 0.1 dBm means: (when vapChannel2ServiceType <50 the value is (dBm value *10) ; when vapChannel2ServiceType>50 the value is (dBm value + 100)*10 MaVEMIB vapChannel2AntennaType .1.3.6.1.4.1.15921.11.2.1.1.19 MA VAP Second channel Antenna Type internal - external MaVEMIB vapAlarms .1.3.6.1.4.1.15921.11.2.1.1.20 MA VAP Alarms; Bits are as follow: For non SISO/MIMO services: 1 - Channel1 Off ; 2 Channel2 Off ; 4- DL Adjustment ; 8 - VAP Faulty ; 16 - Over Temperature when SISO/MIMO services: 1 - DL Adjustment ; 2 - Over Temperature; 4 - VAP Faulty MaVEMIB vapAlarmMask .1.3.6.1.4.1.15921.11.2.1.1.21 MA VAP Alarm Mask MaVEMIB vapOverallStatus .1.3.6.1.4.1.15921.11.2.1.1.22 MA VAP Overall Status MaVEMIB maVEEvents .1.3.6.1.4.1.15921.11.9 MobileAccess VE Events Dual-Band MobileAccessVE Instant Coverage Solution User Manual 86 Appendix B – MobileAccess VE Dual Band MIB Tree Structure (Version 1.8) Module Node Name OID String Description MaVEMIB maVEEventsParams .1.3.6.1.4.1.15921.11.9.1 MobileAccess VE Events Parameters MaVEMIB maVETrapDeviceType .1.3.6.1.4.1.15921.11.9.1.1 Device Type MaVEMIB maVETrapDeviceSerial .1.3.6.1.4.1.15921.11.9.1.2 MaVEMIB maVETrapDeviceName .1.3.6.1.4.1.15921.11.9.1.3 Name of the Trap MaVEMIB maVETrapDeviceIndex .1.3.6.1.4.1.15921.11.9.1.4 Master VCU port MaVEMIB maVETrapDevicePortIndex .1.3.6.1.4.1.15921.11.9.1.5 the unit itself or Slave VCU port MaVEMIB maVETrapEventText .1.3.6.1.4.1.15921.11.9.1.6 Event description MaVEMIB maVETrapSeverity .1.3.6.1.4.1.15921.11.9.1.7 Trap Severity MaVEMIB maVENotify .1.3.6.1.4.1.15921.11.9.2 MobileAccess VE Notify MaVEMIB maVETraps .1.3.6.1.4.1.15921.11.9.2.0 MobileAccess VE Traps MaVEMIB vcuChannel1DLPowerLow .1.3.6.1.4.1.15921.11.9.2.0.1 The input RF power is 15 dB lower than max expected power (or no signal) MaVEMIB vcuChannel1DLPowerHigh .1.3.6.1.4.1.15921.11.9.2.0.2 when input RF power is above the defined max expected power MaVEMIB vcuChannel2DLPowerLow .1.3.6.1.4.1.15921.11.9.2.0.3 when input RF power is 15 dB lower than max expected power (or no signal) MaVEMIB vcuChannel2DLPowerHigh .1.3.6.1.4.1.15921.11.9.2.0.4 when input RF power is above the defined max expected power MaVEMIB vcuChannel1ServiceOff .1.3.6.1.4.1.15921.11.9.2.0.5 when service is off MaVEMIB vcuChannel2ServiceOff .1.3.6.1.4.1.15921.11.9.2.0.6 when service is off MaVEMIB vcuFaulty .1.3.6.1.4.1.15921.11.9.2.0.7 when VCU HW is faulty MaVEMIB vcuOverTemperature .1.3.6.1.4.1.15921.11.9.2.0.8 when VCU temperature is above threshold MaVEMIB vcuMismatchType .1.3.6.1.4.1.15921.11.9.2.0.9 When VCU services types is different than VAP services types MaVEMIB vcuAdjustment .1.3.6.1.4.1.15921.11.9.2.0.10 when VCU adjustment has failed (or cable too long) Dual-Band MobileAccessVE Instant Coverage Solution User Manual Serial Number 87 Appendix B – MobileAccess VE Dual Band MIB Tree Structure (Version 1.8) Module Node Name OID String Description MaVEMIB vapAdjustment .1.3.6.1.4.1.15921.11.9.2.0.11 when VAP adjustment has failed (or cable too long) MaVEMIB vapChannel1ServiceOff .1.3.6.1.4.1.15921.11.9.2.0.12 when VAP service is off MaVEMIB vapChannel2ServiceOff .1.3.6.1.4.1.15921.11.9.2.0.13 when VAP service is off MaVEMIB vapFaulty .1.3.6.1.4.1.15921.11.9.2.0.14 when VAP HW is faulty MaVEMIB vapOverTemperature .1.3.6.1.4.1.15921.11.9.2.0.15 when VAP temperature is above threshold MaVEMIB vcuHeartbeat .1.3.6.1.4.1.15921.11.9.2.0.16 system keep alive notification MaVEMIB vcuConnected .1.3.6.1.4.1.15921.11.9.2.0.17 VCU connected MaVEMIB vcuDisconnected .1.3.6.1.4.1.15921.11.9.2.0.18 VCU disconnected MaVEMIB vapConnected .1.3.6.1.4.1.15921.11.9.2.0.19 VAP connected MaVEMIB vapDisconnected .1.3.6.1.4.1.15921.11.9.2.0.20 VAP disconnected Dual-Band MobileAccessVE Instant Coverage Solution User Manual 88
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : Yes Page Count : 97 Page Layout : OneColumn XMP Toolkit : XMP toolkit 2.9.1-13, framework 1.6 About : uuid:c0d24345-978e-44b5-a476-fa6918fa11b7 Producer : Adobe PDF Library 9.0 Source Modified : D:20110622092256 Modify Date : 2011:07:27 16:01:21+02:00 Create Date : 2011:06:22 13:16:48+03:00 Metadata Date : 2011:07:27 16:01:21+02:00 Creator Tool : Acrobat PDFMaker 9.0 for Word Document ID : uuid:d19d5df4-9ddf-4d48-9c0a-d9084fa73ed1 Instance ID : uuid:760ac888-c064-473a-9826-8d5ff4e4fe4a Subject : 1 Format : application/pdf Title : EnCOVER Dual-Band Creator : to-the-POINT Tagged PDF : Yes Author : to-the-POINTEXIF Metadata provided by EXIF.tools