OWNER'S MANUAL MODEL NO. 580.327140 RAFTSMAN° PORTABLIE GENERATOR, CUSTOMER HELPLINIE 120-240 VOLT/4200 WATT 12-VOLT D-C BATTERY CHARGER DELUXE PORTABLE GENERATOR HOURS: Mon.- Frl. 8 a.m. to 5 p.m • Assembly • Operation CAUTION: Read and Follow • Customer Responsibilities ell Safety Rules end Instructions • Service and Adjustment Before Operating This Equipment • Repair Parts (CST) SEARS, PanNo. B2552 ROEBUCK Rev-I (3/27/98) and CO., Hoffman Estates, IL 60179 U.S.A. CRAFTSMAN° OWNER'S MANUAL 120/240 VOLTS / 4200 WATT A-C 12 VOLTS D-C BATTERY CHARGER DELUXE PORTABLE GENERATOR MODEL No. 580.32714O Each Portable Generator has its own model number. Each engine has its own part number. The model number for your Portable Generator will be found on a decal attached to the unit. IF YOU NEED REPAIR SERVICE The part number for your engine will be found on the Blower Housing of the engine adjacent to the spark plug. All parts listed herein may be ordered through Seam, Roebuck and Co. Service Centers and most Retail Stores. OR PARTS WHEN ORDERING REPAIR LOWING INFORMATION: FOR REPAIR SERVICE CALL THIS TOLL FREE NUMBER PARTS, ALWAYS • PRODUCT-- PORTABLE • MODEL NUMBER--580.327140 • PART NUMBER • PART DESCRIPTION GIVE THE FOL- GENERATOR 1"800"4" REPAIR (1-800-473-7247) FOR REPLACEMENT PARTS INFORMATION AND ORDERING, CALL THIS TOLL FREE NUMBER: 1-800-FON-PART (1-800-366-7278) Your Sears merchandise has added value when you consider that Sears has service units nationwide staffed with Sears trained technicians....professional technicians specifically trained on Sears products, having the )arts, tools and the equipment to ensure that we meet our pledge to you, we service what we sell. SEARS ROEBUCK and CO., Hoffman Estates, IL 60179 U.S.A. SAFETY RULES CAUTION: ALWAYS DISCONNECT SPARK PLUG WIRE AND PLACE WIRE WHERE IT CANNOT CONTACT SPARK PLUG, TO PREVENT ACCIDENTAL STARTING WHEN SET'rING UP, TRANSPORTING, ADJUSTING OR MAKING REPAIRS TO YOUR GENERATOR. IMPORTANT THIS GENERATOR IS DESIGNED FOR OUTDOOR USE ONLY. USING THIS GENERATOR INSIDE ANY BUILDING OR ENCLOSURE INCLUDING THE GENERATOR COMPARTMENT OF A RECREATIONAL VEHICLE (RV), IS DANGEROUS. FIRE OR AN EXPLOSION MAY RESULT. NO USER PERFORMED MOD F CAT ONS, NCLUD NG VENTING OF EXHAUST AND/OR COOLING VENTILATION, WILL ELIMINATE THE DANGER. • If this unit is used for backup power in the event of a utility power failura, take the followingsteps: BEFORECONNECTING THE GENERATOR TO AN ELECTRICAL SYSTEM OPEN THE MAIN CIRCUIT BREAKER OR MAIN SWITCH SERVING THE SYSTEM TO ISOLATE THE GENERATOR SYSTEM FROM THE ELECTRIC UTILITY. FAILURE TO ISOLATE THE GENERATOR AND UTILITY SYSTEMS MAY RESULT IN DAMAGE TO THE GENERATOR AND MAY ALSO RESULT IN INJURY OR DEATH TO ELECTRIC UTILITY WORKERS DUE TO BACKFEED OF ELECTRICAL ENERGY. • This generator supplies dangerously high electrical voltages. Use care to prevent extremely hazardous and possibly lethal electrical shock. Never permit any unqualified person(s) to operate or service the unit. • DO NOT operate this equipment in the rain, while standing in water, while barefoot, or while hands or feet are wet. Dangerous electrical shock will result. The spark arrestor muffler can become extremely hot. DO NOT operate this equipment in areas where combustible material such as grass, leaves or paper products can come in contact with the muffler. Maintain all wiring, extension cords, etc., in good condition. Worn, bare, frayed, or otherwise damaged wiring and cord sets may cause dangerous electrical shock and may also result in damage to equipment and/or property. The National Electrical Code requires that the generator be properly connected to an approved earth ground. Local electrical codes may also require proper grounding of the unit. See ASSEMBLY section for mere grounding information. Wire gauge sizes of wiring and cord sets must be large enough to handle the maximum electrical load to which they will be subjected. Most devices require cord sets rated 125 AC volts at 20 to 30 amperes or 250 AC volts at 20 amps (or greater). Some devices may require a higher or lower rating. Refer to the Owner's manual of the electrical device for the manufacturer's recommendations. Cord sets that are too small in diameter or too long will overheat, become damaged and may cause property damage and/or electrical shock. The generator engine consumes oxygen and gives off DEADLY carbon monoxide gas through its exhaust system. This dangerous gas if breathed in surf c ent concentrations, can cause unconsciousness or even death. Operate this equipment out- • • • • • doors only, in well ventilated areas where exhaust gases cannot accumulate and endanger people or animals. • • • • • • • • • Gasoline is extremely FLAMMABLE and its vapors are EXPLOSIVE. Comply with all laws regulating the storage and handling of gasoline. DO NOT permit smoking, open flames, sparks or heat in the vicinity while handling gasoline. Avoid spilling gasoline on a hot engine. DO NOT fill fuel tank: while engine is running or hot. Clean off any spilled gasoline before starting engine. DO NOT fill fuel tank completely full. Allow room at top of tank for fuel expansion or fuel may expand and overflow onto a hot engine. Drain all gasoline from tank before transporting your generator inside your car or other vehicle. DO NOT store the generator with fuel in tank where gasoline vapors might reach an open flame, spark, or pilot light, as on a fumace, water.heater, dryer, etc. FIRE or an EXPLOSION might result. DO NOT insert any object or tool through cooling air slots or openings of the engine or generator, even if the eng=ne is not running. Damage to the unit or personal injury may result. DO NOT attempt to change the engine govemed speed.. Factory settings are correct when you racalve the unit. Excessively high engine speeds may result in injury or damage to equipment. DO NOT use the unit if it has been damaged. Repair or replace all damaged or defective components before you run the unit. DO NOT permit children to operate or service the generator. Read your Owner's Manual carefully. Only persons who are familiar with these safety rules and have been properly instructed in the use of this product should be permitted to use the product. LOOK FOR THIS SYMBOL TO POINT OUT IMPORTANT SAFETY PRECAUTIONS. MEANS "ATTENTIONII! BECOME ALERTI!! YOUR SAFETY IS INVOLVED." IT I I CONGRATULATIONS on your pumheae of a Sears Craftsman Generator. It has been designed, engineered and manufactured to give you the best possible dependability and performance. Should you experience any problem you cannot easily remedy, please contact your nearest Sears Service Center/Department or call the 1-800 number listed on the front of this manual. We have competent, well-trained technicians and the proper tools to service or repair this unit. Please read and retain this manual The instructions will enable you to assemble and maintain your generator properly, Always observe the 'SAFETY RULES." PRODUCT SPECIFICATIONS Generator Specifications RATED MAXIMUM POWER 4200 Watts (4.2 kW) RATED VOLTAGE 120/240 Volts a-c RATED MAXIMUM LOAD CURRENT 35/17.5 a-c amperes RATED FREQUENCY 60 Hz at 3600 rpm PHASE Single Phase BA'I-FERY CHARGE MODEL NUMBER Amps: Volts: 10 DC Amps 12 volts DC 580.327140 Engine Specifications SERIAL NUMBER DATE OF PURCHASE. RATED HORSEPOWER 7.8 at 3600 rpm DISPLACEMENT 220cc SPARK PLUG: Type: Champion RC12YC or or equivalent 0.030 inch !0.76ram) Set Gap to: THE MODEL AND SERIAL NUMBERS WILL BE FOUND ON A DECAL A'I-T'ACHED TO THE GENERATOR STATOR CAN. YOU SHOULD RECORD BOTH SERIAL NUMBER AND DATE OF PURCHASE AND KEEP IN A SAFE PLACE FOR FUTURE REFERENCE. GASOLINE CAPACITY 4 U.S. gallons OIL (620ml) SAE 30 Oil SAAE10W- 30) E 5W-20 or 5W-30 summer winter MAINTENANCE AGREEMENT A Sears Maintenance Agreement is available on this product, Contact your nearest Sears store for details. CUSTOMER NOTE: Your generator is equipped with a spark arrestor muffler. The spark arrestor must be maintained in effective working order by the owner/operator. In the State of California a spark arrestor is required by law (Section 4442 of the California Public Resources Code). Other states may have similar laws. Federal laws apply on federal lands. RESPONSIBILITIES • Read and observe the safety rules. • Follow regular schedule inmaintaining, caring for and using your generator, • Followtheinstructionsunder'Maintenance"and age" sections of this Owner's Manual. "Stor- TABLE OF CONTENTS SAFETY RULES .................................. MAINTENANCE PRODUCT CONTENTS AGREEMENT SPECIFICATIONS OF HARDWARE INSIDE COVER RECOMMENDATIONS. ............................. 1 SERVICE ....................................... 1 STORAGE 3 TROUBLESHOOTING 3 WIRING DIAGRAM ......................................... ..................... ...................................... MAINTENANCE AND ADJUSTMENTS ................................... ASSEMBLY .......................................... OPERATION SERVICE ....................................... 4-8 9-10 11 .................. 12 .................................................................... 12 POINTS ...................... 13 14 REPAIR PARTS ....................................................... 16-21 WARRANTY 22-24 ............................................................ PARTS ORDERING. .................... BACK COVER Index -AAir Cleaner... ......... Assembly ................ -R- -H4, 10 3 Head boils .............. 11 Receptacles .............. Retorque head bolts ....... 3 11 -I- -BBefore Starting ............ Battery Charging ........... Battery Safety ............. Idle Control ............... 5 7 6 6 -LLow Oil Shutdown .......... 8 Lubrication .............. -CCarburetor. .............. Circuit Breakers .......... Cord Sets ................ Customer Responsibilites .... --M-11 3,5 3 1 -EEngine Carburetoradjustment ........ 5,9 11 Ot/level .................... 11 Speed ..................... 11 Electrical Loads ........... 8 Maintenance Agreement .................. Cleaning generator............ Engine maintenance........... General Recommendations..... Generator Maintenance ........ -O9 Operation ............... 4-8 8 -p- Gasoline ................. 5 Grounding Lug ............ 3 Parts, repair ........... 2 Safety Rules ...... inside cover Service and Adjustments... 11 Service Recommendations . 12 Specifications ............. Starting Engine ............ Stopping Engine ........... Storage ................. 1 5 6 12 -TTroubleshooting .......... 13 -W- OilLevel ................. Overloading .............. -G- 1 9 9 9 9 -S- 16-21 Warranty .............. 22-24 Wattage Reference Guide... Widng Diagram ........... 8 14 ASSEMBLY Your AC generator was completely assembled at the factory. It is ready for use after it has been propedy serviced with the recommended lubricating oil and fuel. R.,RCI--I/_ED 3NtlRE COI_ IF YOU HAVE ANY PROBLEMS WITH THE ASSEMBLY OF YOUR GENERATOR, PLEASE CALL THE GENERATOR HELPLINE AT 1-800-222-3136. IMPORTANT: ANY ATTEMPT TO RUN THE ENGINE BEFORE IT HAS BEEN SERVICED WITH THE RECOMMENDED OIL WILL RESULT IN AN ENGINE FAILURE. TO REMOVE GENERATOR FROM Set the carton on a flat rigid surface with 'qHIS SIDE UP" arrows pointing upward. • • Carefully open the top flaps of shipping carton. Cut down corners at one end of shipping carton and lay that side of carton down flat. • Remove packing material, carton fillers, etc. • Remove generator from shipping carton. SHIPPED LOOSE WITH ; ; i:i , N_JIWAL(N) GROUND(G) CARTON • PARTS 120 V_3 FIG. 2 _vd Set UNIT • • Battery Charge Cables Spark Plug Wrench and Screw Driver • • EngineOil Wheel Kit F)Tc-_d (c-re_) FIG. 3 GROUNDING THE GENERATOR CORD SETS AND CONNECTOR PLUGS 120 VOLTS DUPLEX RECEPTACLE Use only high quality, ! well-insulated, extension i cords with the 120-volt "duplex"type electrical receptacles (Fig. 1). All cord sets used should be rated 125 volts at 15 a-c amps or greater for most electrical devices. FIG. 1 Keep extension cords as short as possible, preferably less than 15 feet long to prevent voltage drop and wires from overheating. 120 VOLTS, 30 AMP RECEPTACLE The National Electrical Code requires that the frame and external electrically conductive parts of this generator be properly connected to an approved earth ground. Local electrical codes may also require proper grounding of the unit. For that purpose, a GROUNDING WING NUT is provided on the base of the cradle (Fig. 4). Generally, connecting a No. 12 AWG (American Wire Gauge) stranded copper wire to the grounding lug and to an earth-driven copper or brass grounding rod (electrode) provides adequate protection against electrical shock. Be sure to keep ground wire attached when you connect electrode. However, local codes may vary widely. Consult with a local electrician for grounding requirements in your area. Proper grounding of generator will help prevent electricel shock in the event of a ground fault condition in the generator or in connected electrical devices. Proper grounding also helps dissipate static electricity, which often builds up in ungrounded devices. For 120 volts, 30 amp locking type NEMA L5-30R receptacle, a well-insulated cord set with a NEMA L5-30P locking type connector plug (Fig. 2) must be properly connected to the receptacle and the desired 120 volts, single phase, 60 Hz, a-c load. The cord set should be rated 30 a-c amperes at 125 volts (or greater) for most electrical devices. #12 AWG STRANDED COPPER WIRE 120/240 VOLTS, 20 AMP RECEPTACLE A 120/240 volts, 20 amp, locking type type mating connector plug (Rg. 3) is required when using this receptacle (L14-2OR). A 4-wire cord set, rated 20 a-c amperes at 250 volts (or greater), is required and must be connected to the plug and to the desired loads. 3 GROUNO4NGROD FIG. 4 OPERATION KNOW YOUR GENERATOR READ THIS OWNER'S MANUAL AND SAFETY RULES BEFORE OPERATING YOUR GENERATOR. Compare the illustrationswith your generator, to familiarize yourself with the locationsof variouscontrolsand adjustments. Save the manualfor future reference. FUELTANK 120-VOLTA.C. 30 AMP RECEPTACLE 120-VOLTA.C. DUPLEXRECEPTACLE 120/240-VOLT A.C. 20 AMP RECEPTACLE AIR CLEANER IDLECONTROLSWlTCl RECOILSTARTER 12-VOLTD.C. RECEPTACLE CIRCUITBREAKERS 120-VOLT A.C. "DUPLEX" RECEPTACLES -- May be used to supply electrical Ix}wer for the operation of 120 volts at 15 amps A.C., single phase, 60 Hz, AC electrical lighting, appliance, tool and motor loads. 120-VOLT A.C., 30 AMP RECEPTACLE -- May be used to supply electrical power for the operation of 120 volts at 30 amps A.C, single phase, 60 Hz, A.C. electrical lighting, appliance, tool and motor loads. 120/240-VOLT A.C., 20 AMP RECEPTACLE -- May be used to supply electrical power for the operation of 120 and/or 240 volts at 20 amps A.C., single phase, 60 Hz, AC electrical lighting, appliance, tool and motor loads. RECOIL STARTER GN engine. -- (not shown) Used for starting the RUN/STOP SWITCH -- (not shown) Set this switch to =RUN" before using recoil starter. Set switch to "STOP" to switch OFF engine. Located on engine block. IDLE CONTROL SWITCH -- With this switch set to ON, printed circuit board in control panel automatically reduces engine speed when no load is connected and increases engine to proper speed when load is applied. However, be sure switch is OFF when starting engine. CIRCUIT BREAKERS (A.C.) -- Each receptacle is provided with a circuit breaker to protect the generator against electrical overload. Breakers are =push to reset" type. SPARK ARRESTOR MUFFLER -- Exhaust muffler lowers engine noise and is equipped with a spark arrestor screen. AIR CLEANER -- Uses a dry type filter element and foam pre-cleaner to limit the amount of dirt and dust that gets in the engine. FUEL TANK --Capacity CHOKE SWITCH of four U.S. gallons (15.2 liters). -- Used when starting a cold engine. 12-VOLT D.C. RECEPTACLE -- Recharge a discharged 12 voltsautomotivetype batterythrough this receptacle. 4 OPERATION IF YOU HAVE ANY PROBLEMS GENERATOR, PLEASE CALL HELPLINE AT 1-800-222-3136. BEFORE STARTING OPERATING YOUR THE GENERATOR • Locate the Idle Control On/Off switch on control panel and set it to OFF position. • Locate the Run/Stop switch (Fig. 6) next to the engine cylinder head and set it to RUN. ENGINE \ ADD OIL: Place generator on a level surface and remove one of .the y..ellowOil .FillCaps (Rg. 5) and add engine oil unti! levm is at point owovernowmg. Check engine oil levee before starting each time thereafter. If oil level is below point of overflowing, fill to proper level. The recommended oils include (during summer months) SAE 30 oil. SAE 10W-30 is an acceptable substitute. During winter months use SAE 5W-20 or 5W-30. DO NOT USE lOW-40. Crankcase oil capacity is about 720ml with oil filter. CAUTION: ANY AI"rEMPT TO CRANK OR START THE ENGINE BEFORE IT HAS BEEN PROPERLY SERVICED WITH THE RECOMMENDED OIL RESULTS IN AN ENGINE FAILURE. FIG. 6 • Close the choke to FULL position (Fig. 7) by sliding it to far position in direction indicated by arrow on air cleaner housing. FULL RUN FIG. 5 ADD GASOLINE: • Use regular UNLEADED gasoline with the generator engine. Regular leaded gasoline may also be used if UNLEADED is not available. Fuel tank capacity is 4 U.S. gallons. _1= CAUTION: DO NOT OVERFILL THEEXPANSION. FUEL TANK. ALWAYS ALLOW ROOM FOR FUEL WARNING: THE CAUTION: ENGINE NEVER START, OR STOP, THE EN- GINE-GENERATOR WITH ELECTRICAL LOADS CONNECTED TO THE RECEPTACLES WITH THE CONNECTED DEVICES TURNED ON. • • • Grasp the starter grip and pull slowly until you feel resistance. Then pull rapidly. Repeatif necessarywith choke opened slightly. • When engine starts, open choke gradually. CONNECTING Start, store and fuel the unit in a level position. Open fuel shut-off valve. ELECTRICAL LOADS • Let engine stabilize and warm up for about five minutes after starting. • Plug in and turn on the desired 120 or 240 volts, single phase, 60 Hertz, a-c electrical loads. • DO NOT connect 240 volts to 120 volts duplex receptacles. • DO NOT connect 3-phase loads to panel receptacles. • DO NOT connect any 50 Hz loads to the generator. • Add up the rated watts of all lights tool appliance and motor loads you are powering at one time. This total should NOT be greater than (a) generator's rated wattage. capac!_ or (b) circuit breaker rating of the receptac=e suoplymg the power. NEVER FILL FUEL TANK INDOORS. NEVER RLL FUEL TANK WHEN ENGINE IS RUNNING OR HOT. DO NOT UGHT A CIGARET OR SMOKE WHEN FILUNG FUEL TANK. TO START FIG. 7 OPERATION STOPPING • • THE ENGINE IDLE CONTROL Disconnect all electrical loads and let engine run at no-load for about five minutes to stablize internal tomperatures of engine and generator. BOLT JAM NUT BRACKET Tum off the engine by moving the Run/Stop switch to STOP position. OPERATING AUTOMATIC IDLE CONTROL An Automatic Idle Control system provides greatly improved fuel economy by operating the unit at its normal high govemed speed only when electrical loads are plugged in and tumed ON. The system consists of (a) an Idle Control Circuit Board, (b) a Sensing Transformer, (c) an Electromagnet, and (d) an Idle Control Switch located on the control panel (Fig. 8). IDLE CONTROL FIG.9 Carburetor "Microadjusting": Once the idle control has been preset, you can use the carburetor's idle screw to make further =microadjustments" to the speed of the angine-generator idle control. • FIG. 8 Engine-generator runs at high governed speed with Idle Control Switch ON only when an electrical load is connected to the generator and turned on. When the electrical load is disconnected, an Electromagnet is energized to pull the engine throttle control against its idle stop. Engine then runs at reduced (idle) speed. NOTE: Engine speeds of less than 38 Hz. could cause the engine to stall if you apply sudden block loads. BA'I-rERY SAFETY The Electromagnet cannot be energized with Idle Control Switch OFF, since its power circuit is open. Engine runs at high govemed speed (about 3600 rpm) whether load(s) are connected or not. ADJUSTING A AND SETTING IDLE CONTROL You will need a volt-ohmmeter to adjust the idle control. You can set and adjust the Idle Control on the Deluxe Generator as follows: With the unit running and warmed up, tum the idle control bolt clockwise (faster speed), or counterclockwise (slower speed) until the engine speed is between 25 and 35 Hz. (1500 - 2100 rpm). See Fig. 9. • Lock the Idle Control Jam nut against the idle control bracket, while the engine is still running at a range of 25 to 35 Hz. WARNING: STORAGE BAI"rERIES GIVE OFF EXPLOSIVE HYDROGEN GAS WHILE CHARGING. AN EXPLOSWE MIXTURE WILL REMAIN AROUND BATTERY FOR A LONG 11MEAFTER IT HAS BEEN CHARGED. THE SUGHTESTSPARK CAN IGNITE GAS AND CAUSE AN EXPLOSION. SUCH AN EXPLOSION CAN SHATTER BATTERY AND CAUSE BLINDNESS OR OTHER SERIOUS INJURY. WARNING: DO NOT PERMIT SMOKING, OPEN FLAME, SPARKS OR ANY OTHER SOURCE OF HEAT AROUND A BAI"rERY. DO NOT USE A UGHTER OR OTHER FLAME FOR CHECKING BATfERY FLUID LEVELS. WEAR PROTECTIVE Presetting Idle Control: Refer to the Idle Control Assembly when you make the initial adjustment oi the idle Control. • Turn the carburetor's idle screw clockwise (faster _4Oez ed ) until the engine speed is between 38 and 40 (2280 - 2400 rpm). GOGGLES, RUBBER APRON AND RUBBER GLOVES WHEN WORKING AROUND A BATrERY. BATTERY ELECTROLYTE FLUID IS AN EXTREMELY CAUSTIC SULFURIC ACID SOLUTION THAT CAN CAUSE SEVERE BURNS. DO NOT PERMIT FLUID CONTACT WITH EYES, SKIN, CLOTHING, ETC. IF SPILL OCCURS, FLUSH AREA WITH CLEAR WATER IMMEDIATELY. 6 OPERATION CHARGING Connectbattery charge cable clamp with red handle to A BA1TERY battery post or terminal indicated by a POSITIVE, or(*). Your generator has the capability of recharging a discharged, 12-volt automotive or utility style storage battery. Do not use the unit to charge any 6-volt batteries. Do not use the unit to crank an engine having a discharged battery. To recharge 12-volt battedas, proceed as follows: • Check fluid level in all battery cells. If necessary, add ONLY distilled water to sever separators in battery cells. DO NOT USE TAP WATER. • If the battery is equipped with vent caps, make sure they are installed and are tight. • If necessary, clean battery posts or terminals. • Connect battery charge cable connector plug to panel recaptacle (Fig. 10). identified by the words =12-VOLT D.C. POS • Connect battery charge cable clamp with black handle to battery post or terminal indicated by a NEGATIVE, NEG, or (--). . Start en.g=ne(see =Starting the Engine" on Page 5). Let the engine run while battery recharges. • When battery has charged, shut down engine (see =Stopping the Engine" on this page). NOTE: Use an automotive hydrometer to test battery state of charge and condition. Follow the hydrometer manufacturer's instruc_onscarefully Generally, a battery is considered to be at 100% state of charge when speQtic gravityof its flu_ (as measured by hydrometer)is 1 260. LOW OIL PRESSURE SHUTDOWN SYSTEM The engine is equipped w_tha low od pressure sensor that shuts down the engine automatically when the oil pressure drops below 6 psi. If the engine shuts down by itself and the fuel tank has enough gasoline, check engine oil level. INITIAL STARTUP A delay built m the shutdown system allows oil pressure to build dunng starting. The delay allows the engine to run for about 10 seconds before sensing oil pressure. SENSING LOW PRESSURE If the system senses low oil pressure during operation, the eng=ne shuts down. As the system shuts down, the low oil light comes ON. However, once the engine has stopped rotating, this light will go OFF. RESTARTING If you try to restart the eng=ne within 5 seconds after it shuts down, the engine may NOT start. The system needs 5 to 10 seconds to reset. FIG. 10 If you do restart the engine after such a shutdown and have not corrected the low oil pressure, the engine runs for about 10 seconds as described above and then stops. 7 OPERATION DON'T OVERLOAD Some electric motors, such as induction types, require about two-and-a-half times more watts of power for s_rtin_ than for running. This surge of power lasts for omy a few seconds when starting such motors. Be sure you allow ;or this high starting wattage when selecting electrical devices to connect to your generator. First figure the watts needed to start largest motor. Add to that figure running watts of all other connected loads. THE GENERATOR Overloading a generator in excess of its rated wattage capacity can result in damage to generator and to connected electrical devices. Observe the following, to prevent overloading the unit: • Add up the total wattage of all electrical devices to be connected at one time. This total should NOT be greater than the generator's wattage capacity. • The rated wattage of lights can be taken from light bulbs. The rated wattage of tools, appliances and motors can usual!y be found on a data plate or decal affixed to the device. • If the appliance, tool or motor does not give wattage, mulitply !20 volts Umas ampere rating to detarmnne watts (volts x amps = watts). WATTAGE The GUIDE below is provided to assist you in determining how many items your generator can operate at one time. REFERENCE GUIDE RUNNING RUNNING WA'I-rS WATTS *Air Conditioner (12,000 Btu) .................................... 1700 Impact Wrench ........................................................... Battery Charger (20 amp) .......................................... 500 *Jet Pump ................................................................... 800 Belt Sander (3") ......................................................... 1000 Lawn Mower .............................................................. 1200 Chain Saw ................................................................. 1200 Microwave Oven ......................................................... 700 *Milk Cooler ............................................................... 1100 Cimular Saw (6-12/') ..................................... 800 to 1000 500 Coffee Maker ............................................................. 1000 Oil Burner on Fumaca ................................................ 300 "Compressor (1 HP) .................................................. 2000 Oil Fired Space Heater (140,000 Btu) ........................ 400 *Compressor (3/4 HP) ............................................... 1800 Oil Fired Space Heater (85,000 Btu) .......................... 225 *Compressor (1/2 HP) ............................................... 1400 Oil Fired Space Heater (30,000 Btu) .......................... 150 Curling Iron ................. ................................................ 700 *Paint Sprayer, Airless (1/3 HP) ................................. 600 "Deep Freeze ............................................................. 500 Paint Sprayer, Aidess (handhelu) ............................... 150 Disc Sander (9") ........................................................ 1200 Edge Trimmer ............................................................. 500 "Refrigerator ............................................................... 600 Electric Nail Gun ....................................................... 1200 Slow Cooker ............................................................... 200 Electric Range (one element) .................................... 1500 *Submersible Pump (1-1/2 HP) ................................. 2800 Electdc Skillet. .......................................................... 1250 *Submersible Pump (1 HP) ....................................... 2000 *Furnace Fan (1/3 HP) .............................................. 1200 *Submersible Pump (1/2 HP) .................................... 1500 Hair Dryer .................................................................. 1200 Sump Pump ................................................................ Hand Drill (1") ............................................................ 1100 *Table Saw (10") ......................................... Television ........................................................ Hand Drill (1/2') ............................................ Radio ................................................................ 750 to 1000 50 to 200 600 1750 to 2000 .200 to 500 Hand Drill (3/8") .......................................................... 500 Weed Trimmer ............................................................ Hand Ddll (1/4') ........................................................... 250 Hedge Trimmer .......................................................... 450 * Allow 2-1/2 times the listed watts for starting these devices. 8 500 MAINTENANCE GENERAL Change oil while engine is still warm from running, as follows: RECOMMENDATIONS The Owner/Operator is responsible for making sure that all periodic maintenance tasks are completed on a timely basis; that all discrepancies are corrected; and that the unit is kept ctean and property stored. Never operate a damaged or defective generator. GENERATOR • Clean area around oil drain plug, remove plug (Fig. 11) and drain oil completely into a suitable container. MAINTENANCE Generator maintenance consists of keeping the unit clean and dry. Operate and store the unit in a clean dry enviorment where it will not be exposed to exceesive dust, dirt, moisture or any corrosive vapors. Cooling air slots in the generator must not become dogged with snow, leaves or any other foreign material. OIL FILTER I Check the cleenliness of the generator fraquentiy and clean when dust, dirt, oil, moisture or other foreign substances are visible on its exterior surface. A NOTE: We DO NOT recommend using a garden hose to clean the generator. Water can enter the engine fuel system and cause problems. In addition, if water entem the generator through coolingair slots,some of the water will be retained in voids and cracks of the rotor and stator winding insulation. Water and dirt buildup on the generator internal windings will eventually decrease the insulationresistanceof these windings. FIG. 11 • When oil has drained, install and tighten oil drain plug. • Remove oil fill plug and insert a clean fill funnel into plug opening. Fill engine crankcase with recommended oil until oil level is at point of overflowing. Do not overfill above the point of overflowing. About 21 ounces (620ml) is required. POUR SLOWLY. • When engine crankcase is filled to proper level. Install and tighten oil fill plug. TO CLEAN THE GENERATOR: • Use a damp cloth to wipe exterior surfaces clean. • Use a soft, bristle brush to loosen caked on dirt, oil, etc. • A vacuum cleaner may be used to pick up loose dirt and debris. Replace Oil Filter: Replace the engine oil filter after first 8 hours of operation, every 50 operating hours thereafter. Low pressure air (not to exceed 25 psi) may be used to blow away dirt. Inspect cooling air slots and opening on the generator. These openings must be kept clean and unobstructed. CAUTION: NEVER INSERT ANY OBJECT OR TOOL THROUGH THE AIR COOLING SLOTS, EVEN IF THE ENGINE IS NOT RUNNING. DAMAGE TO THE UNIT OR PERSONAL INJURY MAY RESULT. • Coat gasket of new filter with engine oil. • Turn the new filter clockwise until its gasket contacts tightly with the filter adaptor. Then tighten by hand an additional 3/4 to one turn. HEAD BOLTS After 50 hours of operation, retorque the head bolts for the GN engine to 4.0 kg/m (29 foot-pounds). OIL LEVEL • See OPERATION sectionon Page 4 for informationon checking oil level. Oil level should be checked before each use or at least every eight hours of operation. Keep oil level maintained. CHANGING Turn oil filter counterclockwise to remove (Figure 11). RETORQUE ENGINE MAINTENANCE CHECKING • The torque sequence is A, B, C, D, E (star pattern). See Fig 12. O B OIL AND OIL FILTER Change oil after first 8 hours of operation. Change oil every 50 hours thereafter. If you are using your generator under dirty or dusty conditions, or in extremely hot weather, change oil more often. J ,_ FROM SPARK PLUG AND KEEP IT AWAY FROM SPARK PLUG. DO THIS EVERYTIME YOU PERFORM ANY MAINTENANCE ON THE PLUG ENGINE OR CAUTION: DISCONNECT SPARK WIRE THE GENERATOR, E C FIG. 12 9 MAINTENANCE SERVICE AIR CLEANER REPLACE Your engine will not run properly and may be damaged if you run it using a dirty air cleaner. SPARK PLUG Change the spark plug every 100 hours of operation or once each year, whichever comes first. This will help your engine to start easier and run better. Replace with Champion RC12YC or equivalent type spark plug. Set spark plug gap (Fig. 14) 0.030 inch (0.76mm). Clean or replace the air cleaner paper filter (Fig. 13) once every 25 hours of operation or once a year, whichever comes first. Clean or replace mere often if operating under dusty or dirty conditions. Clean foam pre-filter every 25 hours of operation or sooner under dusty conditions. / "_.030" FEELER GAUGE /_ A I (0.76mm) COMPLETE AIR CLEANER SYSTEM INSTALLED ON THE ENGINE. THIS COULD RESULT IN PRECAUTION: NEVER RUN THIS UNIT WITHOUT THE MATURE WEAR TO THE ENGINE. FIG. 14 CLEAN SPARK ARRESTOR SCREEN The engine exhaust muffler has a spark arrestor screen. Inspect and clean the screen every 100 hours of operation or once each year, whichever comes first. p PRECLEANER PAPER FILTER A WORKING ON IT. CONTACT WITH A HOT MUFWARNING: LET THE MUFFLER COOL BEFORE I FLER OR ENGINE CAN CAUSE SEVERE BURNS. NOTE: If you use your generator on any forest-covered, brush° covered or grass-coveredunimprovedland, it must have a spark arrestor. The spark arrestormustbe maintainedin goodcondition by the owner/operator. FIG. 13 • Clean and inspect the spark arrestor as follows: • To remove the heat shield from the muffler (Fig. 15), remove the nine screws that connect the shield to the muffler. To clean or replace foam pre-filter: MUFFLER * Remove air cleaner cover, then foam pre-tilter. • Wash pre-filter in soap water. Squeeze pre-c eaner dry in clean cloth (DO NOTTWlST). Saturata pre-c eaner in clean engine oil and then wrap pre-ti tern clean dry cloth to squeeze out excess oil (DO NOT TWIST). • SPARK ARRESTOR SCREEN Clean air cleaner cover before installing it. To clean or replace paper air filter: • Remove air cleaner cover; then remove foam pre-fi ter Iservice if necessary) and remove paper tilter. , Clean air filter by tapping it gently on a solid surface. If the filter is too durty replace it with a new one. D spose of the o d f Iter properly. b Clean air cleaner cover then insert pre-filter into cover. Next insert new paper filter into cover to hod pre-filter in place and assemble all of them to the base of the air cleaner. Heat Shield FIG. 15 Remove four screws screen. that attach the spark arrestor Inspect screen and replace if tom, perforated or otherwise oamaged. DO NOT USE a defective screen. If the screen is not damaged, clean it with a commercial solvent. • 10 Reattach the screen and the heat shield. SERVICE AND ADJUSTMENTS ENGINE SPEED CAUTION: ENGINE SPEED WAS PROPERLY ADJUSTED AT THE FACTORY AND SHOULD REQUIRE NO ADDITIONAL ADJUSTMENT. DO NOT AI"rEMPT TO CHANGE ENGINE SPEED. IF YOU BEUEVE THE ENGINE IS RUNNING TOO FAST OR TOO SLOW, TAKE YOUR GENERATOR TO AUTHORIZED SERVICE CENTER FOR REPAIR ANO ADJUSTMENT. CHANGING ENGINE GOVERNED SPEED WILL VOID ENGINE WARRANTY. FEELER ALLEN 0 GAUGE _LOOSEN JAM NUT Your generator runs at • constant speed. This constant operating speed is maintained by a mechanical, flyweight type, fixed speed governor. DO NOT try to adjust the govemed speed setting for the following reasons: • High engine speeds are dangerous and increase the dsk of personal injury or damage to equipment. • Low engine speeds impose a heavy load on the engine when sufficient engine power is not available and may shorten engine life. • The generator will supply correct rated AC frequency and voltage only at the proper speed. Some connected electrical devices could be damaged by incorrect frequency and/or voltage. ADJUSTING FIG. 16 THE CARBURETOR The carburetor of your generator set is preset at the factory. DO NOT TAMPER WITH THE CARBURETOR as this will void the warranty for the emission control system. If your generator is to be used at an altitude above 5,000 feet, consult with a Sears Authorized Service Facility regarding high altitude jetting changes. ADJUSTING "F_jhten]am nut to 65-85 inch-pounds ("/-10 N-m). VALVE CLEARANCE After the first 50 hours of operation, you should adjust the valve clearance in the engine. When adjusting valve clearanca, the engine room temperature and the piston should be Center ('rDC) of its compression stroke closed). Correct clearance is 0.05-0.1mm. clearance as follows: should be at at Top Dead (both valves Adjust valve • Loosen the rocker arm jam nut. Use an allen wrench to turn the pivot ball stud while checking clearance between the rocker arm and the valve stem with a feeler gauge (Fig. 16). • When valve clearance is correct, hold pivot bell stud with allen wrench and tighten rocker arm jam nut with a crows foot. Tighten the jam nut to 65-85 =nch-pounds torque. After tightenin_,l the jam nut, recheck valve clearance to make sure it did not change (Fig. 17). FIG. 17 1! SERVICE RECOMMENDATIONS MAINTENANCE OPERATION Every 8 Hours or 25 Hours or Every SOHours or Every 100 Hours or Every NOTE 1: Change oil and oil filterafter first 8 hours of operation and then every 50 hours thereafter. Change sooner when operating under heavy load or in dusty or dirtyenvironmentor in high ambient temperature. NOTE 2: Clean more often when operatingthe unit under dirty or dusty conditions. STORAGE The generator should be started at least once every seven days and allowed to run at least 30 minutes. If this cannot be done and you must store the unit for more than 30 days, use the following information as a guide to prepare it for storage. STORAGE INSTRUCTIONS WARNING: NEVER STORE ENGINE WITH FUEL IN THE TANK INDOORS OR IN ENCLOSED, POORLY ,_ VENTILATED AREAS, WHEREORFUMES CAN REACH AN OPEN FLAME SPARK PILOT LIGHT AS ON A FURNACE, WATER HEATER, CLOTHES DRYER OR OTHER GAS FURNACE. • Remove spark plug and pour about 1/2 ounce (15ml) of engine oil into cylinder. Crank slowly to distribute oil I _ CAUTION: SPRAY FROMSLOWLY. SPARK PLUG HOLE WHENAVOID CRANKING ENGINE • Install spark plug. Do not connect spark plug wire. • Clean dirt, oil and grease from cylinder, cylinder head, fins, blower housing, rotating screen and muffler area. • Close fuel shut-off valve, located beneath the fuel tank. GENERATOR • Clean the generator as outlined on Page 5 ("To Clean the Generator'). ENGINE • Check that cooling air slots and openings on generator are open and unobstructed. • Run engine for about five minutes to warm it. NOTE: If you did use =gasohol,"drain fuel tank, then run engine until engine stops from lack of fuel. OTHER _ TAINER OUTDOORS, AWAY FROM OPEN FLAME; WARNING: DRAIN FUEL INTO APPROVED CON- I] BE SURE ENGINE IS COOL J TIPS Do not store gasoline from one season to another. • NOTE: Using a fuel additive such as Sears Craftsman® Fuel Stabilizer, or an equivalent, will prevent gum depositsfrom forming in the generator's fuel system. • STORAGE • While engine is still warm, drain oil from crankcase. Refill with fresh oil. See BEFORE STARTING ENGINE on Page 2 for oil recommendations. Replace your gasoline can if it starts to rust. Rust and/or dirt in your gasoline can cause problems when you use it with this unit. Store in clean and dry area. _k 12 DANGER: STORAGE COVER IS FLAMMABLE. DO NOT PLACE THE STORAGE COVER OVER A HOT GENERATOR. LETTHE UNIT COOL FOR A SUFFICIENT TIME BEFORE PLACING THE COVER ON THE UNIT. IF YOU PLACE THE COVER ON THE UNIT BEFORE GENERATOR IS COOL, THE COVER COULD START ON RRE. TROUBLESHOOTING PROBLEM Engine is running, 10utno AC output is available. POINTS CORRECTION CAUSE 1. One of the circuitbreakers is open. 1. Reset circuitbreaker. 2. Fault in generator. 3. Poor connectionor defective cord set. 4. Connected device is bad. 2. Contact Sears Service DepadmenL 3. Check and repair. 4. Connect another device that is in good condition. Engine runs good at no-load but "bogs down"when loads are connected 2. Engine speed istoo slow. 3. Generator is overloaded. 1. Disconnectshorted electrical load. 2. Contact Sears Service Department. 3. See "Don't Ovedoad the Generator Shoded generatorcircuit. on Page 6. 4, ContactSears Service Department. Short circuitin a connected load. 1. 4. Engine will not start;or starts and runs rough. 12. 13. 14. 6. 7. 8. 9. 10. 11. 12. 13. 14. Replace spark plug. Drain gas tank; till with fresh fuel. Open choke fully and crank engine. Contact Sears Service Department. Contact Sears Service Department. Contact Sears Service Department. Contact Sears Service Department. Contact Sears Service Department. Replace battery. 1. 2. Out of gasoline. Low oil level. 1. 2. Fill fuel tank. . 7. 8. 9. 10. 11. Engine shuts down dunng operation Engine lacks power. 1. Load is too high. 2. Dirtyair filter. Engine "hunts" or faltera. 1. Choke is opened too soon. 2. Carburetoris runningtoo rich or too lean. 13 1. 2. 3. 4. 5. Set switch to RUN. Run/Stop Switchset to STOP. Dirty air cleaner Out of gasoline. Stale gasoline. Spark plug wire not connected to spark plug. Bad spark plug. Water in gasoline. Overchoking. Excessivelyrichfuel mixture. Intake valve stuckopen or dosed. Engine has lost compression. Intake valve stuck opan or closed. Engine compressionlost. Failed battery. 1. 2. 3. 4. 5. Clean or replace air cleaner. Fill fuel tank. Drain gas tank; fillwith fresh fuel. Connect wire to spark plug. Fill crankcase to properlevel. 1. See "Don't Overload the Generator" on Page 6. 2. Replace air filter. 1, Move choke to halfway positionuntil engine runs smoothly. 2. Contact Sears Service Department. W_[RZNG D| AGRAH BtTTERy I_CT]F JER CRAFTSMAN 4200 WATT DELUXE AC GENERATOR 8 REPAIR PARTS 580.327140 8 7 \ 23 "-17 10 3 ITEM 1 2 3 4 5 PARTNO. 83976 83975 66818 66821 68867C 6 6S868C 7 8 g 10 11 12 75207A 75207G 82538 84134 83514 83970 DESCRIPTION ITEM PART NO. CONTROL PANEL (1 REQ.) CONTROL BOX (1 REQ,) 120 VOLTS AC OUTLET 2(REQ.) 12 VOLTS DC OUTLET (1 REQ.) 120/240 VOLTS, 20 AMP TWISTLOCK OUTLET (1 REQ.) 120 VOLTS, 30 AMP (1 REQ.) TWISTLOCK OUTLET (1 REQ.) 30 A CIRCUIT BREAKER (1 REQ.) AMP CIRCUIT BREAKER (2 REQ.) ON/OFF ROCKER SWITCH (1 REQ.) RUBBER GROMMET (1 REQ.) 10 A CIRCUIT BREAKER (1 REQ.) SYSTEM CONTROL BRD. (1 REQ.) 13 84028 14 15 16 17 18 19 67022 85584 84534A 84534(3 84198 84197 21 22 23 24 25 26 75476 22264 51715 84534B 84335 82542 15 OESCRIPTION IDLE CONTROL TRANSFORMER (1 REQ) RUBBER GROMMET (1 REQ) BUS BAR (1 REQ) 3.0 X 12MM SCREW (2 REQ) 3.5 X 18MM SCREW (4 REQ) CIRCUIT BREAKER SHIELD (3 REQ) CIRCUIT BREAKER RETAINING BAR (1 REQ) 4.0 X 16MM SCREW (2 REQ) M4 LOCK WASHER (4 REQ) M3 HEX NUT (8 REQ) 3.5 X 12MM SCREW (10 REQ) WIRE HARNESS (1 REQ) DC OUTLET RETAINING BAR (1 REQ) I)rawin 8 No.87407 CRAFTSMAN 4200XL DELUXE PORTABLE GENERATOR 580.327140 REPAIR PARTS 7O 56 '41 71 _5 66 49 50 "_ DETNL " X " ,€6 'Jr/ 3 52 73 I0 35 69 11 3O 68 22- 14 16 CRAFTSMAN rn M PART 1 2 3 4 5 6 7 8 9 10 11 12 13 14 16 17 18 19 20 21 22 23 25 26 27 30 32 33 34 35 36 37 38 B2551 84021 ENGA1386 66365 84141J 83540J -65791 67451 22129 86307 47480 84508 52858 83208 66476 89476 70644 84346 40976 83083 83071 81917 66825B 85652 45771 74908 86308 65795 66849A 67022 84132 66386 66849 4200 WATr DELUXE AC GENERATOR CSY. 1 1 1 1 1 1 1 1 2 4 1 2 8 1 2 1 1 3 2 1 1 1 1 2 2 4 4 1 1 2 1 1 2 CRADLE, 4200 W SUPPORT, Engine ENGINE, 7.8 HP HOUSING, Engine Adapter ROTOR, Assembly STATOR, Assembly BEARING WASHER, M8 Rat WASHER, M8 Lock HHMS, 5/16- 24 x 3/4 Long HHCS, 5/16 - 24 x 7" Long MOUN_, Vi_ 45° NU'I_,M8 _ BRACKE'_,Muffler SCREV_, M6 - 1.00 x 12 GASK_, Exhaust PPHMS, M8- 1.25 x 20 Long PPHMS, M8 x 35 Long SCREV_, M8 - 1.25 x 20 SCREEN, Spark An'estor MUFFLER PIN, Roll M4 x 10 BEARING, Rear Carrier MOUN_, Vibra'don NLrI_,M8 Hex TAPTITE, M5 - 0.8 x 10 Long BOLT,M6 - 1.0 x 115 Stator RECTIFIER, Batten]Charge TAFT]'iE, M5 - 0.8 x 20 Long GROMME-'I_,Rubber MODULE, Drive ASSY., Brush Holder TAPTTTE,M5 -0.7x 16 Long 17 580.327140 REPAIR PARTS tTEM PARTNO. Q_. 39 41 42 43 44 46 47 46 49 50 51 52 53 54 55 56 58 60 61 62 64 66 67 68 59 70 71 72 73 74 75 67025 86494 .86292 77395 83465 78831B 80270 78299 85134 83311 84042 84687 85000 14353621 23762 26850 57593 B2550 92982 B2549 77026 93826 96409 77816 B1432 B1779 B2347 B2555 51757 52857 46476 1 1 5 4 4 4 1 1 1 1 1 1 1 1 1 2 1 1 1 2 1 1 1 1 1 2 2 1 2 2 2 DESCRIPTIO__._._._N COVER, Bearing Carrier SCREW, M6 - 1.0 x 16 Lg. Wing HHCS, 10 - 16 x Self DdU NU'E M6 Range Lock GROMMET, Tank HHMS, M6 - 1.0 x 60 (black) VALVE, Tank BUSHLNG, Pla_c Tank CAP, Fuel TANK, Fuel SHIELD, Heat INSULATION, #2 1/4"Thick CLIP, Insula'don WIRE, Ground SHAKEPROOF, #10 SHAKEPROOF, M6 -RE, Cable Mount DECAL, Codm_lPanel DECAL, Danger DECAL, Heat Shield DECAL, Data DECAL, Start Instructions DECAL, 1-800# DECAL, MufflerVVaming ASSEMBLY, ControlPanel COVER, Hinge END C_, Tube HANDLE HHCS, M6- 1.0 x45 NLr_, M6 - 1.0 Loddng CAP PLUG, 1"Square Drawing No.B2554 REPAIR PARTS CRAFTSMAN 4200 WATT DELUXE AC GENERATOR 580.327140 36 3B 7 7 46 4O 1|A-lIB _12 9 47 13 2 t8 ITEM PART NO. 1 2 3 4 5 6 7 6 9 10 11 12 13 14 15 16 17 18 19 2O 21 22 23 24 25 26 78621 76389 88411 89665A 77168 88057 76390 83337A 78658 78659 21857A 76354 81695 76359 78645 76365 72683 98752 89096 88156 21704 78691 76367 76362 78692 786O6 DESCRIPTION Control Rod Assembly (1 req,) Piston Pin (1 mq.) Piston Ring Set (1 req.) Gear Cover Assembly (1 reg.) M8 x 52mm Head Bolt {5 req.) Piston (1 req.) Pin Retainer Ring (2 req,) CrankshaftAssembly(1 req.) Governor"R" Pin (1 req,) Govern_ ArmThrt_ Washer{1 req.) Crankcase Assembly (1 req.) GovernorArm (1 req,) Oil Seal (1 req.) GovernorGear Assembly(1 req.) GovernorGear C-Ring (1 req.) GovernorSpool (1 req.) 1/8"NPT Pipe Plug (1 req.) Camshaft Assembly (1 req.) Crankcase Gasket (1 req.) Valve Stem Seal (1 req.) Cylinder Head Gasket (1 req.) Oil PressureRelief Cover (1 req,) Oil Pressure Spring(1 req.) 5/16" Ball (1 req.) M5 Form Screw (1 req,) M6-1.0 x 12ram Screw (4 req.) ITEM 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 /8 PART NO. 76361 89230 99922 86293 88401 84186 83192 86254 76349 21705B 90082 90081 88396A 83235 80336 88397 77161 77160 76307 88403 72657 88412 76329 21942 DESCRIPTION GovomorGearThrustWasher(1 req.) M8-1.25 x 35ram Screw (6 req.) Spring Washer (1 req.) Valve Spring Retainer (1 req.) ValveSpring (2 req.) Va_e Sp_g Wear Washer(2 re¢) Gerotar Set (1 mq.) "o" Ring(1 req.) Searing (1 req.) CylinderHead Assembly(1 req.) ExhaustValve (1 req.) Intake Valve (1 req.) Push Rod (1 req.) Tappet (2 req.) Oil Pick-upAssembly(1 req.) RockerCover Gasket (1 req.) Pivot Ball Stud (2 req.) GN-t90/220 RockerArm (2 req.) Rocker Arm Jam Nut (2 req.) Push Rod Guide Plate (t req.) 1/4" NPT Pipe Plug(1 req.) Rocker Cover Assembly(1 req.) Plastic Oil Fill Plug (1 req.) Complete Long Block CRAFTSMAN 4200 WAn" DELUXE AC GENERATOR 580.327140 CARBURETORANDAll CLEANER REPAIR PARTS MUFFLER 73 31 45 47 48 / 36 39 -./7 49 44 50 41 ITEM PART NO. 31 32 35 36 39 90947 90051 80316 9O948 91846 41 42 80303 78631 43 44 45 46 47 48 49 97747 78607 66476 59635 78601 78602 83504 ITEM 73 74 75 76 DESCRIPTION 1 1 2 1 1 Breather Hose Manifold Head Gasket M6 x 30mm Screw Intake Manifold Carburetor/Air Box Gasket Canal Cover Carburetor Manifold Gasket PART NO. 89476 40976 88688 66476 83038 DESCRIPTION Muffler Gasket (1 req.) M8 x 20mm Capscrew (2 req,) Small Muffler (1 req.) M6 x 12 HHFS (2 req.) Spark Arrestor (not shown) 79A 79B Carburetor (220cc) Air Cleaner Base 1 1 1 1 M6 x 12mm Capscrew #8 x 3/8" Plastite Screw Air Filter Precleaner Choke Knob j FLYWHEEL 9O / 81 19 ITEM PART NO. DESCRIPTION 78 79A 80 81 90 82774 77182T 83312 81810 A2482 Woodruff Key (1 req.) Flywheel (1 req.) Conical Washer (1 req.) M16 Hex Nut (1 req.) Recoil Cup (1 req.) 8O CRAFTSMAN 4200 WA_" DELUXE AC GENERATOR 580.327140 REPAIR PARTS 8 25, I0 12 26 23 24 _ L.O.S. WITH ENGINE \ 27 20 29 28 30 PART NO. QTY. 20 72347 21 86962 84195 L.E.D. Assembly (1 req.) Low Oil Shutdown Decal (1 req.) Spar k Plug= (1 req.) Governor Lever (1 req.) 22 85953 Wear Washer (1 re(].) 10 85620 Black Sleeving 23 83502 Adjust Screw (1 req.) 12 84329 3-pin Male Connector 24 83512 M8x 13 00185271 Housing (1 req.) White Wire Assembly (1 req.) 25 78604 Governor Spring (1 req.) 14 22097 M6 Lock Washer (2 req.) 26 66476 M6 x 12ram Capscrew (1 req.) 15 82891 M6 x 30mm Screw (2 req.) 27 83503 MS Lock Nut (1 req.) 16 81675 Ignition Coil (1 req.) 28 83781 Governor Bracket (1 req.) 17 84274 Tinnerman 29 86384 Governor Rod (1 req.) 18 87221A Low Oil Shutdown 30 86037 Anti-lash Spring (1 req.) ITEM ITEM PART NO. DESCRIPTION 7 78653 Run/Stop Switch (1 [eq.) 8 85272 9 Module 19 45756 (1 req.) DESCRIPTION 15mm Taptite Screw (1 req.) Clamp (1 req.) (1 req.) M6 x 10ram Screw (1 req.) 20 CRAFTSMAN 4200 WAn" DELUXE AC GENERATOR 580.327140 REPAIR PARTS RECOIL STARTER OIL SWITCH AND OIL FILTER 91 / 82 2 6 86 WITH OIL FILTER ITEM 1 2_ 3 4 5 6 88 4 PART NO. DESCRIPTION 94820 91848 84892 92978 99236 70185 EXPANSION PLUG (1 REQ.) OIL FILTER GASKET (1 REQ.) OIL FILTER ADAPTER (1 REQ.) M6 x 20ram SCREW (2 REQ.) OIL PRESSURE SWITCH (1 REQ,) OIL FILTER (1 REQ.) 21 ITEM 82 83 84 85 86 87 88 89 90 91 PART NO. DESCRIPTION 92984 45756 78609 78608B 90695A 89739 66476 A2799 A2842 78651C TOP WRAPPER (1 REQ.) M6 x 10ram SCREW (4 REQ.) COVER BOLT (2 REQ.) SEARS AIR BOX COVER (1 REQ.) BLOWER HOUSING (1 REQ.) LOWER WRAPPER (1 REQ.) M6 x 12ram CAPSCREW (9 REQ.) RECOIL ASSEMBLY (1 REQ,) RECOIL CUP (I REQ.) BACKPLATE (1 REQ.) FOR CALIFORNIA RESIDENTS ONLY WHEN SEEKING SERVICE IN CALIFORNIA CALIFORNIA EMISSION CONTROL WARRANTY STATEMENT YOUR WARRANTY RIGHTS AND OBLIGATIONS The California Air Resources Board and Sears Roebuck and Co., USA (Sears), are pleased to explain the emissions control system warranty on your 1995 and later lawn and garden equipment engine. In California new utility and lawn and garden equipment engines must be designed, built, and equipped to meet the State's stringent anti-smog standards. Sears must warrant the emission control system on your lawn and garden equipment engine for the periods of time listed below provided there has been no abuse, neglect, or improper maintenance of your lawn and garden equipment engine. Your emission control system includes parts such as the carburetor and the ignition system. Where a warrantable condition exists, Sears will repair your lawn and garden equipment engine at no cost to you. Expenses covered under warranty include diagnosis, parts, and labor. MANUFACTURER'S WARRANTY COVERAGE The 1995 and later utilityand lawn and garden equipment engines are warranted for two years. If any emission related part on your engine (as listedbelow) is defective,the part will be repaired or replaced by Sears. OWNER'S WARRANTY RESPONSIBILITIES As the lawn and garden equipment engine owner, you are responsiblefor the performance of the required maintenancelistedin yourOwner'sManual. Sears recommendsthatyou retainall receiptscovering maintenance on your lawn and garden equipmentengine, but Sears cannotdeny warranty solelyfor the lack of receiptsorfor your failure to ensure the performance of all scheduledmaintenance. As the lawn and garden equipment engine owner, you should be aware that Sears may deny you warranty coverage if your lawn and garden equipment engine or a part of it has failed due to abuse, neglect, improper maintenance, unapproved modifications, or the use of parts not made or approved by the original equipment manufacturer. You are responsible for presenting your lawn and garden equipment engine to a Sears authorized repair center as soon as a problem exists. Warranty repairs should be completed in a reasonable amount of time, not to exceed 30 days. If you have any questionsregardingyour warranty rightsand responsibilities,you should contact your nearest authorized service center or call Sears at 1-800-473-7247. WARRANTY COMMENCEMENT DATE The warranty period beginsonthedate the lawnand gardenequipment engineisdelivered tothe original,end-use purchaser. LENGTH OF COVERAGE Sears warrantsto the initialownerand each subsequentpurchaserthat theengine isfree from defectsin materials and workmanshipwhichcause the failure of a warranted part for a period of two years. 22 WHAT IS COVERED REPAIR OR REPLACEMENT OF PARTS • Repair or replacement of any warranted part will be performed at not charge to the owner at an approved Sears servicing center. • If you have any questions regarding your warranty rights and responsibilities, you should contact your nearest authorized service center or call Sears at 1-800-473-7247. WARRANTY PERIOD Any warranted part which is not scheduled for replacement as required maintenance, or which is scheduled only for regular inspection to the effect of =repair or replace as necessary" shall be warranted for 2 yearS. Any warranted part which is scheduled for replacement as required maintenance shall be warranted for the period of time up to the first scheduled replacement point for that part. DIAGNOSIS The owner shall not be charged for diagnostic labor which leads to the determination that a warranted part is defective if the diagnostic work is performed at an approved Sears servicing center. CONSEQUENTIAL DAMAGES Sears may be liable for damages to other engine components caused by the failure of a warranted part still under warranty. WHAT IS NOT COVERED All failures caused by abuse, neglect, or improper maintenance are not covered. ADD-ON OR MODIFIED PARTS The use of add-on or modified parts can be grounds for disallowing a warranty claim. Sears is not liable to cover failures of warranted parts caused by the use of add-on or modified parts. HOW TO FILE A CLAIM If you have any questionsregardingyour warranty rightsand responsibilities,you should contact your nearest authodzed service center or call Sears at 1-800-473-7247. WHERE TO GET WARRANTY SERVICE Warranty services or repairs shall be provided at all Sears authorized service centers. MAINTENANCE, REPLACEMENT AND REPAIR OF EMISSION RELATED Any Sears approved replacement part used in the performance of any warranty maintenance related parts will be provided without charge to the owner if the part is under warranty. PARTS or repair on emission EMISSION CONTROL WARRANTY PARTS LIST 1. Carburetor Assembly 2. Ignition System a. Spark Plug, covered up to maintenance schedule. b. Ignition Module 3. Crankcase Breather Tube 4. Exhaust Manifold MAINTENANCE STATEMENT The owner is responsible for the performance of all required maintenance as defined in the owners manual. 23 TWO YEAR LIMITED WARRANTY FOR DELUXE PORTABLE GENERATORS SEARS warrantsto the Odginal purchaserthat the aHernatorand engine for itsportablegeneratorwillbe free from defectsin rnstedaisor workmanshipfor the itemsand periodset forth below fromthe date of odginalpurchase.This warrantyis not _ransferableand appliesonlyto portablegeneratorsdriven bythe GN-SeriesSears warrantedengine. Altemstor Engine CONSUMER* 2 years (2nd year parts only) 2 years (2nd year parts only) COMMERCIAL* I year I year ' NOTE: For the purpose of this warranty "Consumer Use" means personal residential householdend emergency use k)yoriginal purchaser, not to be used as • pdmary source of power. "Commercial Use" means ell other uses, Including rental, €onstnJCtlon,commerclst,primary source of realdentfalhousehold power end income producing purposes. Dnco a generator has exbedenced commercial use, It shall thereafter be considered a commercial use generator for lhe purpose of this warranty. :)udngsaid warrantyperiod,SEARS will, at its option,repairor replaceany part which,upon examinationby SEARS, is =oundto be defectiveunder normaluse and service**. Startingbatfadesare notwarrantedby SEARS. All transportation ;osts underwarranty,includingreturnto the factory if necessary,are to be bome by the purchaserand prepaidby him. This tvarmnty does not cover normalmaintenanceand service and does not apply to a generatorset, alternatoror engine,or )arts whichhave been subjectedto improperor unauthorizedinstallationor alteration,misuse,negligence,accident,overoeding,overapseding,impropermaintenance,repairor storage so as, in SEARS'sjudgment,to adverselyaffect itsperformance and reliability. ** NORMALWEAR: As with all mechanical devlcea, engines need periodic parts service and replacement to perform well. This warranty will not cover repair when normal use has exhausted the life of a pert or engine. THERE IS N(_ OTHER EXPRESS WARRANTY. SEARS HEREBY DISCLAIMSANY AND ALL IMPLIED WARRANTIES, INCLUDING BUT NOT LIMITED TO THOSE OF MERCHANTABILITYAND FITNESS FOR A PARTICULARPURPOSE TO THE EXTENT PERMITTED BY LAW. THE DURATIONOF ANY IMPLIEDWARRANTIES WHICH CANNOT BE DISCLAIMED IS LIMITED TO THE TIME PERIOD AS SPECIFIED IN THE EXPRESS WARRANTY. LIABILITY FOR CONSEQUENTIAL INCIDENTAL OR SPECIAL DAMAGES UNDER ANY AND ALLWARRANTIES IS EXCLUDED. Somestates de not allow limitationson how long an impliedwarrantylasts,or the exclusionor limitationof incidentalor consequential damages,so the above limitationsor exclusionsmay not applyto you. Thiswarrantygivesyou specific legal rightsand you may also have otherrights,whichvery from state to state. Forservice, see yournearest SEARS authorizedwarrantyservice facility.Warrantyservicecan be performedonlyby e SEARS authorizedservicefacility. This warrantywill not apply to service at any otherfacility. At the time of requestingwarranty service,evidenceof originalpurchasedate mustbe presented. SEARS, ROEBUCK AND CO., Hoffman Estates, IL 60179 U.S.A 24 WHEEL KIT ASSEMBLY INSTRUCTIONS Tools Required: 1. 15/16" box or open end wrench (or socket wrench). 2. 2 13mm wrench, metric box wrench or open end wrench (or socket wrench). Parts in Wheel Kit Box: 1. 87005A 2 2. B1760 2 Retaining Pin 10" Diameter Wheel 3. 93728C 2 Axle Stud 4. 94222Q 2 5/8-18 Lock Jam Nut 5. 49808 4 Flat Washer 6. B1764 1 Mounting Leg / 4 6 USE EXISTING FASTENERS TO SECURE: ITE:H #6 Assembly Instructions: 1. 2. Place the bottom of the generator cradle on a flat, even surface. Place axle stud through wheel retainer on cradle frame. 4. 5. Use wrench to secure the axle stud to frame with 5/8-18 jam nut. Install the other axle stud in the same manner. NOTE: Be sure to install the wheel with raised hub inboard. 6. Place flat washer over axle stud, tip unit and install the wheel. 7. Retain wheel on axle stud with flat washer and retaining pin. Install other wheel on remaining axle shaft in the same manner. 8. Remove two front nuts and lock washers from vibration mounting with 13mm wrench. Use these nuts to retain the mounting leg. 2_ SE/AR8 MANUAL DEL PROPIETARIO MODELO NO. 580,327140 CRAFTSMAN° 120/240 VOLTIOS / 4200 VATIOS C-A 12 VOLTIOS C-D CARGAS DE BATERIA GENERADOR HORAS: Lun. - Vie. 8 a.m. a 5 p.m (TCE) PRECAUCION: Lea y Slga las Reglas de Segurldad • Instrucciones Antes de Operar Este Equlpo SEARS, NTo. deParteB2552 ROEBUCK Rev-I (3/27/98) PORTATIL DE LUJO • Ensamble • Operaci6n • Responsabilidades • Servicio y Ajuste • Partes de Recambio and CO., del Cliente Hoffman Estates, IL 60179 U.S.A. SE/A/R MANUAL DEL PROPIETARIO CRAFTSMAN° 120/240 VOLTIOS/4200 12 VOLTIOS C-D CARGAS DE BATERIA GENERADOR MODEL NO. 580.327140 VATIOS C-A Cada Maquina modelo. PORTATIL DE LUJO Lavadora de Alta Presi6n tiene su propio nt_mero de El ndmero de modelo de su maquina lavadora de presi6n serd encontmdo en la calcomania adherida a la unided. Todas las partes enlistadas aqui adelante pueden ser ordenadas a trav6s de los Centros de Servicio de Sears, Roebuck and Co. y la mayoria de las Almacenes de Venta al Detal. Sl NECESITA REPARACIONES O PARTES PARA SERVICIO REPARACION ESTE NUMERO SIEMPRE PROPORCIONE LA SIGUIENTE INFORMACION CUANDO ESTE ORDENANDO PARTES DE REEMPLAZO: • PRODUCTO PRESION m MAQUINA • NUMERO DE MODELO-- • NUMERO DE LA PARTE • DESCRIPCION LAVADORA DE ALTA DE LLAME A 580.327140 DE LLAMADA GRATUITA 1-800-4,REPAIR (1-800-473-7247) PARA INFORMACION ACERCA DE PARTES DE RECAMBIO Y ORDENES, LLAME A SETE NUMERO DE LLAMADA GRATUITA: 1-800-FON-PART DE LA PARTE A su mercancia de Sears se le ha afiadid valor debido a que Sears tiene unidades de servicio en toda la naci6n equipades con t6chnicos entrenados por Sears...tdcnicos profesionales entranados especificamente en los productos de Sears, poseyendo las partes, la herramientas y los equipos neceesarieos para asegurale que vamos a satisfacer nuestro comprosio con usted, le damos servicio a Io que vendemos. (1-800-366-7278) SEARS, ROEBUCK and CO., Hoffman Estates, IL 60179 U.S.A. Impre_ en les I_.U.A. REGLAS DESEGURIDAD HACER CONTACTO CON DESCONECTE LA BUJIA Y ASIELPREVENIR ACCIDENTALES CUANDO ESTA A PRECAUCION: SIEMPRE CABLE DEENCENDIDO6 LA BUJIA Y COLOQUELO DONDE NO PUEDA k INSTALANDO, TRANSPORTANDO, AJUSTANDO O HACIENDO REPARACIONES EN SU GENERADOR. IMPORTANTE ESTE GENERADOR ESTA DISEI_IADOUNICAMENTE PAPA SER UTILIZADO EN EXTERIORES. ES PELIGROSO UTILIZAR ESTE GENEPADOR DENTRO DE CUALQUIER EDIFICACION O RECINTO, INCLUYENDO EL COMPARTIMIENTO PARA GENERADOR DE UN VEHICULO RECREACIONAL (VR). PUEDE OCURRIR EXPLOSION. I.AS MODIFICACIONES REALIZADAS POR EL USUARIO, INCLUYENDO VENTILACION DEL ESCAPE Y/O VENTILACION DE ENFRIAMIENTO NO ELIMINARAN EL PELIGRO. dat_arse,y pueden causar daSo a la propiedady/o des• Siesta unidad es ulJlizadacomo fuente de energla de carga eldctdca. reserva en ca.sode que falle el sorvlclo de energia, siga los siguientespasos: ANTES DE CONECTAR EL GEN• Elmotor_ gperador consumeoxygen? yproducegas ERADOR A UN SISTEMA ELECTRICO, ABRA EL INoe monoxioooe carbonoMORTAL a traves oe susistema TERRUPTOR AUTOMATICO PRINCIPAL DE CIRde escape. Este gas es deligroso, si es respirado en CUITO O EL INTERRUPTOR PRINCIPAL QUE ACTIVA concentraciones suflcientes puede causar I_rdida del EL SISTEMA PAPA AISLAR EL SISTEMA DEL GENcor_c,im_entoy a_n la muerte. Unicamento operar este EPADOR DEL SERVICIO ELECTRICO. LA FALLA AL equtpoen extertores, en dreas bien ventiladasdonde los AISLAR EL GENEPADOR Y LQS SISTEMAS DE SERV_s_s del escape no se puedan acumular y poner en ICIOS PUEDE CAUSAR DANO AL GENERADOR Y ro la gente o los animales. PUEDEN TAMBIEN RESULTAR EN LESION O • La gasolina es extmmadarnente INFLAMABLE y sus MUERTE DE LOS TRABAJADORES DEL SERVICIO vapores son EXPLOSIVOS. Cumpla todas las leyes que ELECTRICO DEBIDOA LA RETROALIMENTACION DE regulan el almacenaje y manejo de la gasolina. NO LA ENERGIA ELECTRICA permda que se fume, llamas abiertas chispaso calor a su alrededor mientras estd manejando gasoPna. Evitar derramar gasolina sobre un motor caliente. NO Ilene el tanque del combustible mientras el motor estd funclonando o est_ caliente. Limpie cualquier derrame de gasolinaantes de encender el motor. • NO Ilene compJetamenteel tanque de combusbble.Deje algo de espac_oen la parte supertordel tanque para la expansi(_ndel combusbble,de otra forma el combustible se puede expandiry derramarse sobre el motorcaliente. • Este generador summistravoltajes elfJctncosaltospeh• Drene toda la gasohna del tanque antes de transportar grosos. Sea cuidadoso para prevenir descargas el_ctnsu generador dentro de su carro u otro vehiculo. cas extremaclamentepeligrosas y posiblemente letales. • NO almacene el generador con combustible dentro del Nunca permtta que persona(s) no cahficada(s) opere o tanquedonde los vaporesde lagasolinapuedan alcanzar de serv_ctoa la untdad una llama abterta, una chispa, o una luz de piloto,como • NO opere este equipobajo la Iluvia,sobre superftciescon en un homo, un calentador de agua, una secadora etc. agua, cuando est_ descalzo, o cuando tonga las manos Puede resultar en FUEGO o EXPLOSION. o los pies hdmedos. Ocurrird una descarga eldctnca • NO inserte ningdn objeto o herramientaa _avds de las pehgrosa ranuras del atre de enfnamiento o de las aperturas del • El sdenciador contrachtspas puede calentarse excesP motor o del generador, a_n cuando el motor no est6 vamente. NO opere este equipo en dreas donde materifuncionando.Puede resultar en da_o a la untdad o en ales combusbbles como pasto hojas o productos de lesk_npersonal. pape puedan entrar en contacto con el silencJador. • NO mtente cambiar la velocidad de r6giman del motor. • Mantonga todas las conexiones el_ctricas, cables de Los valoresde fdbrtcason correctoscuando usted recibe extensibn, etc., en buenas cond_cJones.Las conexiones la unldad Las velocidades del motor excestvamente eldctricas o juegos de cables gastados gastados, altas pueden resultaren lesi6no da_o al equipo. deshilachados, o daRadosde otra torma pueden causar • NO utthcela unidad si est_ da_ada. Repare o reemplaos descarga eldctrica peSgrosay tambi_n puede ocas_onar todos los componentesdaSades o defectuososantes de daRoal equtpo y/o la propmdad. hacer funcionar la unidad. • El Cbdigo EI6ctnco Nactonel requiem que el generador • NO permitaque n_5osoperen o den serv_ctoel generador. estd conectado correctamente a tierra fis_caaprobada. Los cbdlgos eldctncos locales tarnbl_n pueden requenr • Lea culdadosamente su Manual del Propietario. Uniuna aproplada conex_(_na tierra de la unidad Vea la camente se debe perm_tirel uso de este producto a secci6n de MONTAJE para mds mformactbn en la con_aarSOnas que conozcan estas reglas de seguddady que exl_)na tierra. yan sido mstruidascorrectamente en la utilizaci(_nde este producto • Los calibres de los cables de los juegos de conex_ones eldctdcasy cables deben set Io suficmntementegrandes para manejar la carga eldcldca mdxima alas cuares ellos serdn sujetos La mayorta de dJspositNosnecesdan de juegos de cables clasificadosen 125 voltiosCA de 20 a 30 amperios o 250 volttosCA a 20 ampenos (o mayor) Algunos disposltivospueden requerir una clasificact6n mayor o menor. Refidrase al manual del Propietario de disposilJvoel6ctricopara las recomendecionesdel fabd_apte..Los jue.gosde cables que son muy peque_os en larnetro o muy largosse sobrecalentardn, para despuds I _ ESTO SIGNIFICA "iATENClONtttt iMANTENGASE ALTERA!!!PRECAUCIONES SU SEGURIOAO DE ESTA EN PELIBUSQUE ESTE SlMBOLO PARA SEI_IALAR IMPORTANTES SEGURIDAD. GRO." I I FELICITACIONES per su compra del Generador Sears Craftsman. Este ha sido disettado, concebido y fabricado para brlndade la mejor conflabilidad y el mejor desempei'lo posible. si _iene cualquier problema qua no pueda solucionar con factlidad, por favor contacte su Centro/Departamento de Servicio Sears mds cercano o Ilame al ndmem 1-800 indicado en la cubiarta de esta manual. Tenamos t_nicos competentes y bien entrenados y las herramientas apropiadas para darle servicio y reparar esta unidad. Por favor lea y conserve este manual. Las instrucciones Io capacitardn para ensamblar y rnantener apropiadamante su generador. Siempre siga la "REGLAS DE SEGURIDAD." ESPECIFICACIONES Especiflcaclones del Generador POTENCIA NOMINAL MAXIMA 4200 Watts (4,2 kW) VOLTAJE NOMINAL 120/240 Voltios AC CORRIENTE DE CARGA NOMINAL MAXIMA 35/17.5 AC amperes FRECUENCIA 60 Hz at 3600 rpm NOMINAL FASE Uno Fase CARGA LA BATERIA Amps: 10 DC amperes Vohtos: 12 Voltios DC Especlflcaclones NUMERO DEL MODELO NUMERO 580.327140 del Motor MOOELO DEL MOTOR GN-220 DESPLAZAIMENTO 220cc BUJIA: Tipo: DE SERIE Espacio Establecido TIEMPO DE OPERACION MAXIMO CON EL TANQUE LLENO (hrs) FECHA DE COMPRA LOS NUMERO DEL MODELO Y DE SERIE SE ENCUENTRAN EN I.A CALCOMANIA ADHERIDA AL GENERADOR DEBE REGISTRAR EL NUMERO DE SERIE Y LA FECHA DE COMPRA Y MANTENERLOS EN UN LUGAR SEGURO PARA REFERENCIAS FUTURAS. ACUERDO DEL PRODUCTO DE MANTENIMIENTO Estd disponible en este producto un Acuerdo de Mantenimiento Sears. Contacte su almac6n Sears mds cercano para detalles. REPONSABILIDADES DELCLIENTE • Lea y siga las reglas de seguridad. • Siga una programacibn de mantenimiento regular, cuidado y utilizaci6n de su generador. • Siga las instrucciones de las secciones de "Mantenimiento" y =Almacenaje" de este Manual del Propietado. CAPACIDAD DE GASOLINA , Champion RC12YC or equivalent 0.030 inch (0.78mm) carga completa 3 carga 1/2 5 4 gallones U.S. ACEITE (mesos de verano) (mesos de invierno) SAE 30 SAE 5W20 o 5W30 CAPAICIDAD 870ml (confinrode aceite) 620ml (sinfiltro deaceite) DE ACEITE NOTA: Este generador estd equipado con un silenciador contrachispas. El contrachispas debe ser mantenido funcionando correctamente pot el propietado/operador. Es requerido por ley un contrachispas en el estado de California (Secci6n 4442 del C6digo de Recursos Pt_blicos de California). Otros estados pueden tener leyes similares. Las leyes federales se aplican en tierras federales. TABLA DE CONTENIDOS REGLAS DE SEGURIDAD ......... PARTE INTERNA ACUERDO DE MANTENIMIENTO RESPONSABILIDADES ESPECIFICACIONES DE LA CUBIERTA ................................. DEL CLIENTE ......................... DEL PRODUCTO ....................... MONTAJ E ....................................................................... OPERACION ................................................................ MANTENIMIENTO ..................................................... SERVICIO Y AJUSTES ................................................ 11 RECOMENDACIONE8 12 DE SERVICIO 1 ALMACENAJE 1 PUNTOS DEL DIAGNOSTICO 1 DIAGRAMA DE CONEXION 3 4-8 ........................ .............................................................. 12 DE AVERIAS .............. 13 ........................................ 14 PIEZAS DE RECAMBIO .......................................... 15-22 GARANTIA ............................................................... 23-26 9-10 Indlce -AAlmacenaje .............. Antes de Encender ......... 12 5 Apagado de Presi6n ........ Baja de Aceite ............ 8 5 Carga de la Bater'B ......... Cargas El_ctricas .......... 7 5 5 -O- -J- Operaci6n............... 4-8 4 -LParado del Motor .......... Lubdcaci6n ............... 5 -M4,10 13 14 -EEncendido del Motor ........ 5 Especificaciones ........... 1 23-26 5 8 Partes, mparaci6n ...... 6 15-22 °R- Mantenimiento Acuerdo .................... 1 Recomendaciones de Servicio .............. Limpieza del Generador ....... Mantenimientodel motor....... RecomendacionesGenemles... Maintenimiento del Generador 9 9 9 9 Reglas de Seguridad .... dentrode la cublelta Responsabilidedes del Cliente ................... 1 Medidas de Seguridad para la Baterla ................. 6 oS- Montaje .................. Motor -GGaranfia .............. Gasolina ................. Guta de Referencia ......... Nivel de Aceite ............ 4 -p11 -DDepurador de Aim ....... Diagn6stico de Avedas ..... Diagrama do Conexi6n ..... Interruptores Automdticos de Circuito ................ Juegos de Cables .......... -CCarburador .............. -N- -J= Ajuste del carburador......... Nivel de aceite ............... Velocidad .................. 3 11 5 11 Servicio y Ajuses ......... Sistema de Enfriamiento..... Sobrecarga ............... 12 11 9 8 -TTerminal de Conexi6n a Tierra .................. Tomas ................... 3 3 , MONTAJE Su generadorCA fue ensambladocompletamenteen la fi'dbrica. Se encuentralistopara ser utilizadodespu_sde haber recibido el servicio apropiado con el aceite lubricante y combustible recomendado. CORDONESDE 3 ALAMBRES SI TIENE PROBLEMAS CON EL MONTAJE DE SU GENERADOR POR FAVOR LLAME A LA LINF_ADE AYUDA DE AL GENERADOR AL 1-800-222-3136. IMPORTANTE: CUALQUIER INTENTO DE HACER FUNCIONAR EL MOTOR ANTES DE HABER RECIBIDO SERVICIO CON EL ACEITE RECOMENDADO RESULTARA EN FALLADEL MOTOR. _ TIERRA PARA RETIRAR EL GENERADOR DE LA CAJA • Coloque la caja sobre una superficieplana y rfgida las fiechas =THISSIDE UP"apuntandohacia arriba. • Abra cuidadosamente las tapas superiores de la caja de envfo. • Corte las esquinas en una de las terminacionesde la caja de envioy acuestela caja porese lado. • Retireel materialde empaque, re,enos de la caja, etc. • Retireel generadorde la caja de envfo. .A--L NEOTRO FIG. 2 CORDONES DE l_]ot y_ _k_ j'J X (cargado) _l_cargado) "_ " TIERRA (verde) JUEGOS DE CABLES Y ENCHUFES CONECTORES FIG. 3 TOMA DOBLE DE 120 VOLTIOS CONECTANDO A TIERRA EL GENERADOR Utilice 0nicamente cables de extensi6n de alta calidad y con buen aislamiento de las tomas el_ctdcastipo "doble" de 120 voltios. Todos los juegos de cables utilizadosdeben ser clasificados como de 125 voltios a 15 CA amperios o mayores para la mayorfade los FIG. 1 dispositivos el6ctricos. Conserve los cables de extensi6ntan cortoscomo sea posible, preferiblementemenosde 15 pies de Iongitud para prevenircaidas de voltajesy sobrecalentamiento de los cables. TOMAS DE 120 VOLTIOS, 30 AM Para la toma NEMA L5-30R con traba por giro 30 amp de 120 voltios, un juego de cables con buen aislamiento con un enchufe conector con treba de giro NEMA L5-30P debe ser apropiadamenteconectadoa la toma y a la carga deseada CA 60 Hz monof&sicade 120 voltios.El juego de cables debe ser clasificadocomo de 30 CA amperios a 125 voltios (o mayor) para la mayorfa de los dispositivosel_tricos (Fig. 2). El Cx_igo El_,ctricoNacionalrequiemque el marcoy las partes conductorasel_:,ctdcas extemas de este generadorestbnconectadas apmpiadamentea una tierra fisica aprobada.Los c6digos eldctricoslocalestambi_npueden requeriruna conexi6na tierra apropiadade la unidad. Pare tal prop6sitoes propomionadoun TERMINAL DE CONEXION A TIERRA en la base del bastidor (Fig.4). Generalmenteconectandoun alambrede cobretrenzado No. 12 AWG (Calibrede AlambreAmericano)al terminalde conexibn a tierra y a un barra (electrodo)dirigida a tierra de cobre o lat6n, propomionauna proteccibnadecuada en contra de descargael6ctrica.Sin embargo,los cbdigoslocalespueden variar bastante.Consultecon un electricistalocal para requisitosde conexi(_na tierraen su_rea. La conexi6n a tierra apropiada del generador le ayudard a previnir descargas eldctricas en el caso que se presente un condici6nde averfa que se descarguea tierra en el generadoro en los dispositivose!_ctricosconectados.La conexiona tierra apropiadatambidn ayuda a disipar la electricidad estdtica, la cual comfinmentese acumulaen los dispositivosno conectados a tierra. ALAMBRE DE COBRE TRENZADO NO. 12 AWG TOMA DE 120/240 VOLTIOS, 20 AMP Es necesario un enchufe conector complementadotipo traba por giro de 120/240 voltios,30 amp cuando estdutilizandoesta toma. Es necesarioun juego de cables de 4 alambres,clasificado en 30 CA amperios a 250 voltios (o mayor) y debe ser conectado al enchufe y alas cargas deseadas. Orden NEMA tipoL14-30P. BARRA (ELECTRODO) 3 FIG. 4 OPERACION CONOZCA SU GENERADOR LEA ESTE MANUAL DEL PROPIETARIO Y LAS REGLAS DE SEGURIDAD ANTES DE HACER FUNCIONAR SU GENERADOR. Compare las ilustraciones con su generador para familiadzarse con las Iocalizaciones de los controles y ajustes. Guarde este manual pare referencias futuras. TANQUEDECOMBUSTIE TOMADE120-VOLTIOS 30AMP DEPURADOR DEAIRE TOMADE 1201240-VOLTIOS _TOMASDOBLES DE12-VOLTIOS INTERRUPTORES AUTOMATICOS DE ClRCUITO TOMAS =DOBLES" DE 120 VOLTIOS - Pueden ser ut=lizadas para summistrar energia el_ctnca para el funcJonamlento de CA de 120 volt=osa 20 amps, monofds=ca, 60 Hz, cargas de =lum=naci6n electnca de CA, electrodom6sticos y motores. TOMA DE 120 VOLTIOS, 30 AMP - Puede ser ut=l,zada para suministrar energta el_=_ctricapara el funcionamiento de CA de La conexi6n a tierra apropiada del generador le ayudard a prevenireldctrica de CA, electrodomdsticos, herremientas y motores. Los conectores de c_erre por g=roson necesarios cuando utlhce esta toma. TOMA DE 120/240 VOLTIOS - Puede ser utilizada para suministrar energia el6ctrica para el funcionamJento de CA de hasta 240 voltios a 30 amps, monofdsica, 60 Hz, cargas de iluminaci6n eldctrica de CA, electrodomdsticos, her- ram=entas y motores. Los conectores de cierre por giro son necesanos cuando utilice esta toma. INTERRUPTORES AUTOMATICOS DE CIRCUITO CA Protege el generador contra la sobrecarga eldctrica. Los mterruptores automdt_cos son del t_po=pulsar para act=vaf' para cargas de 15 amp, 20 amp y 30 amp. SILENCIADOR CONTRACHISPAS - El silenciador del escape t,ene una pantalla contrachispas. INTERRUPTOR RUN/STOP DEL MOTOR - Debe ser colocado en RUN para encender el motor. Coloque el interruptor en STOP para detener el motor. MEDIDOR DEL NIVEL DE COMBUSTIBLE - Indica el nivel del combustible en el tanque de combustible. OPERACION ANTES DE ENCENDER Agmgue EL MOTOR Aceite de Motor Antes del Arranque Inlclal: Quite una de las Tapas Amadllas de Llenado del Aceite (Figura 2 en la Pagina3) y agregue aceite de motor hasta que el nivel del aceite est6 en el punk) de rebose. Examine el nivel de aceite del motor antes de arrancar de ahora en mds. Si el nivel del aceite estd debajo del punto de rebose, Ilene hasta el nivel apropiado (Fig. 5). Los aceites recomendados rank) los meses de verano: sustituto aceptable. Durante 20 o 5W-30. NO USE SAE incluyen los siguientes: DuSAE 30. SAE 10W-30 es un los moses inviemo: SAE 5W10W-40. La capacidad de aceite del critter es unos 720ml. aditivos especiales. I SI SE OPERA EL GENERAl)OR EN LA LLUVIA, EL I USARIO PODRIA RECIBIR UN CHOQUE ELEC-I ADVERTENCIA! TRICO Y LA HUMEDAD SE DEBE PODRIA EL GENERADOR DA_IAR LOSSECO. COM- I PONENTES DEL GENERADOR. C6mo arrancar el motor:. Desconnecte todas las cargas el6ctricas del generador, • Localice el interrupter de Encender/Apagar (On/Off) del Control de Marcha en VacJo en el tablero de control y p6ngalo en la posicibn OFF. • Localice el interruptor de Funcionar/Parar (RUN/STOP) ala par de la base del depurador de aim y p6ngalo en RUN(Figura 6). No use I FUNCIONAM clonar o arramcar el motor antes de hacede el PRECAUCION: Cualquler tentative de hater funservlclo suite en fella aproplado del motor. con et acelte recomendado re- ! I .---T SEMI-ABIERTO FIG. 6 FIG. 7 • C ierre el estrangulador en la posici6n FULL (TOTAL) deslizdndolo a]a posici6n ala)eda en la direcci6n indicada por una flecha en la caja del depurader de aire (Figura 7). Agarre la empuSaclura del arrancador y jale lentamente hasta que se sienta resistencia. Entoncesjale rdpidamente. Repita el procedimiento si fuera necesario con el estrangulador (choke) ligeramente abierto. FIG. 5 Agregue gasoline: Llene el tanque de combustible con gasolina UNLEADED (SIN PLOMO) fresca y limpia. Tambidn puede utilizar gasolina grade REGULAR con plomo. NO UTILICE GASOL[NA PREMIUM. SEA CUIDADOSO DE NO LLENAR EN EXCESO EL TANQUE DE COMBUSTIBLE. Cuando el motor arranca, abra el estrangulador gradualmente. CONEXION PRECAUCION: No Ilene exceso el tanque de cornbustlble. Slempre deJe espaclo pare la expansl6n del combustible. ADVERTENCIA: NUNCA LLENE EL TANQUE DE COMBUSTIBLE DENTRO DE UNA INSTALACION. NUNCA LLENE EL TANQUE DE COMBUSTIBLE CUANDO EL MOTOR ESTA FUNClONANDO O CALIENTE NO ENClENDA UN ClGARRILLO O FUME MIENTRAS ESTA LLENDAND EL TANQUE DEL COMBUSTIBLE. COMO OPERAR EL GENERADOR generador con dls.posltlvos o apmtos en modo de I funclonamlento ON" cusndo esten conectadas PRECAUCION! Nunca arranque, o pare, el motor-a J los tomacorrientes del _lenerador. 5 DE CARGAS ELECTRICAS • Utilizer este generador para operar cargas de 120/240 voltios, monofdsicas, 60 Hz, =luminaci6n CA, electrodom_sticos, herramientas y motores. • Conecte y encienda las cargas el_ctricas de 120 o 240 voltios, monofdsicas, de 60 Hertz que se deseen. • NO conecte 240 voltios alas voltios, 120 voltios, 30 amp. • NO conecte panel. • NO conecte ninguna carga de 50 Hz al generador. • Sume los vatios clasificados de todas las cargas de las luces, herramientas, electrodom6sticos y motores alas _)ue. le estd suministrando energta en un momento. icno total NO deDe ser mayor a (a) la capacidad de va!iaje clasificado del genemdor, o (b) la clasificact6n eel interruptor automdtico del cimuito de la tome que estd suministrando energia. Vea "NO Sobrecarge el Generador" en la Pdgina 8. tomas dobles de 120 ninguna carga trif_sica alas tomas del OPERACION PARADO DEL MOTOR • PERNO DE CONTROL EN VACIO Desconecte todas las cargas el6ctdcas de las tomas del panel del generador. Nunca encienda o detenga el motor con los dispositivos el6ctricos conectados y encendidos. • Deje funcionar el motor sin cargas por vados minutos pare estabilizar las temperaturas internes del motor y el generador. • Coloque el Interruptor Run/Stop en STOP. Espere que el motor se detegna completamente (Fig. 6). • Cierre la Vdlvula de Corte de Combustible. COMO OPERAR EL CONTROL DE MARCHA EN VAC|O Este provee econom'm en la operecibn de la unidad dando mds rendimiento del combustible cuando estd operando la misma a niveles de velocidad mdximos y norrnales. Teniendo en cuenta que 6ste ahorro se obtiene solamente cuando los aparetos estan conectados al generador. AUTOMATICO FIG. 9 CONTROL DE MARCHA EN VACIO • Asequre la Contretuerca del Control Libre contra la mdnsula del control libre mientras que el motor est_ funcionando dentro de un rango de 25 a 35 Hz. "Micro Ajuste" del Carburador: Una vez al control libre ha sido precalibrado puede utilizer el tomillo del libredel carburedor para realizar "micro ajustes" adicionales ala velocidad del control libre del motor-generador. • FIG. 8 El sistema consiste de (a) un Tablero de Circuito de Control de Marcha en Vacio, (b) un Transformador Detector, (c) un Electromagneto, y (d) un Interruptor de Control de Marcha en Vacio Iocalizado en el tablero de control (Figura 8). El motor-generador funciona a una velocidad alta regulada con el Interruptor de Control de Maroha en Vacio en ON cuando una carga el6ctdca se conecta el generador. Cuando la carga eldctrica se desconecta, se activa un Electromagneto para jalar el Choke del motor contra el paro del sistema de marcha en vacio. El motor entonces funciona a una velocidad (marcha en vacto) reducida. El electromagneto no puede ser activado con el Interruptor de Control de Maroha en Vacio en OFF, puesto que el circuito de potencia estd abierto. El motor funciona a una velocidad alta regulada (a unas 3000 rpm) si la(s) carga(s) estd(n) conectada(s) o no. AJUSTE Y CALIBRATION MENSULA DEL CONTROL LIBRE Necesitard un volti-metro-ohmimetor para ajustar el control libre. Puede colocar y ajustar el Control Libre en el Generador De Lujo como se describe a continuaci6n: Precalibraci6n de Control Libre: Refi_rase al Ensamble del Control Libre cuando realice el ajuste inicial del Control Libre. Con la unidad funcionando y caliente, gire en sentido de las manecillas del reloj el pemo del control libre (velocidad mds rdpida), o en sentido contrario de las manecillas del reloj (velocidad n_s lenta) haste que la velocidad del motor est6 entre 25 y 35 Hz (1500-2100 rpm). Vea la Figure 9. Gire en sentido de las manecillas del reloj el tomillo de ajuste del libre del carburador (velocidad mds rdpida) hasta que la velocidad del motor est_ entre 38 y 40 Hz. (2280-2400 rpm). NOTA: Las velocidades del motor de menos de 38 Hz, poddan causar que el motor se apague si aplica inesperadamente cargas muy grandes. MEDIDAS DE SEGURIDAD DE LA BATERIA GAS DE HIDROGENO EXPLOSIVO PRECAUClON: El almacenar lie batedas hace que ellis produzcan gas de hldr6geno EXPLOSIVO mientras se estdn cargando. Una mezcla explosive permanecerst alrededor de la bateda por largo tiempo despu_s que ha sldo cargada. La m4s mfnlma chlspa puede encender el gas y causer una explosl6n. Dicha explosl(_n puede destrulr la bateda y causer ceguera u otras leslones serlas. PRECAUCION: NO permita que se fume, IlamM, abiertas, chispas o cualquier fuente de calm" elrededor de una bateda. NO utillce nlnguna clise de encendedor u otra clase de llama pare Ilumlnar y reviser el nlvel del liquido de la bater_a. Use anteojoe de protecci6n, delantal de caucho y guantce de caucho cuando trabaje alrededor de la bater_a. ACIDO SULFURICO CAUSTICO PRECAUClON: El I[quido electrolftico de la bat=de es una solucl6n de dcldo sulf0dco extremadamente c_ustJca que puede causer quemaduru severse. NO permita que el I_quido entre en contacto con ojos, plel, vestldos, etc. Sl sucede un derrame, I_vese con ague Umpla inmedlatamente. OPERAClON CARGANDO UNA BATERIA Su generador tiene la capacided de recargar una bate(m de autorn6vil de 12 voltios descargada o una bater'm para almacenar tipo servicio. No u_lice la unidad pare cargar batefias de 6 voltios. No utilios la unidad para hacer girar un motor que tenga una batefia descargada. Para recargar las bate(ms do 12 voltios, proceda como se describe a contJnuaci6n: • Revise el nivel del rquido en todas las celdas de la bator'B. Si es neossario, afiada UNICAMENTE agua destJlada para cubrir los separadores de las celdas de la batsrta. NO UTILICE AGUA DE GRIFO. • Si la bater'm estd equipada con tapes de ventilaci6n, asegurese que estdn instaladas y apretadas. • Si es necesado, limpie los bomes de la bateria o los terminalesenerador. • Conecte el enchufe del conector del cable de carga de la bateria a la toma del panel (Fig. 10) indentificado con las palabras =12-VOLT D.C." • Conecte la abrazadera del cable de carga de la bateria con la agarradera negra al bomo de la bateda o terminal marcado con un NEGATIVO, NEG o (-). • Encienda el motor (vea "Encendido del Motor" en la Pagina 5). Deje funcionar el motor mientras la bats(== se recarga. • Cuando la batefia se ha cargado, apague el motor (vea "Parado del Motor" en esta pdgina). NOTA: Utilice un hidrbmeter para autorn6viles pare prober el estado de carga y condici6n de la baterla. Siga cuidadosmente las instrucciones del fabricante del hidr6meter. En general, se considera qua una bater'm estd en el 100% de estado de carga cuando la gravedad especifica de su liquido (medido por el hidrbmeter) es de 1.260. SISTEMA DE APAGUE DEL ACEITE DE PRESION BAJA El motor viene equipado con un detector de prasi6n baja aceite qua apaga el motor automdticamen_,e cuando la presi6n del aceite cae debajo de 0.422 Kg/cm =. Si el motor se apaga por si mismo y el tanque de combustible tiene suficiente gasolina, examine el nivel del aceite del motor. Arranque Inciah Un retraso incorporado en el sistema de apague permite que la presi6n se acumule durante el arranque. El retraso permite que el motor funciona por unos 10 segundos antes de detecter la presi6n del aceite. 12 VOLTIOS D.C. C6mo Se Detecta la Presfon Baja: Si el sistema detecta presi6n baja del acaite duranto la operaci6n, el motor se apaga. AI apagarse el motor, el indicador de bajo nivel de aceite se enciende (ON). Sin embargo, una vez qua el motor ha parado de girar, esta luz se apaga (OFF). C6mo Volver e Arrancar: Si intenta volver a arrancar el motor en 5 segundos despu6s de que se apaga, el motor puede NO arrancar. El sistema necesita de 5 a 10 segundos para restablecerse. PO RECEPTACULOs__- Si usted vuelve a arrancar el motor despu6s de este de apague y no ha corregido la presi6n baja del aceite, el motor funciona por unos 10 segundos como se descrlb|6 anteriormente y Iuego se para. BATERIA DE 12 VOLTIOS FIG. 10 ? OPERACION Si el electrodomt_sUco o el motor no tlenen el vatlaje, multiplique 220 voltios por la potancia de amperlo para detarminar los vaUos (voltios x amps = vatios). NO SOBRERECARGEELGENERADOR Este generador est_ equipedo con dos interruptores automdticos del cimuito de 15 amp, uno de 20 amp y otro de 30 amp, los cuales protegen la unidad en contra de sobrecarga el_ctdca. El sobrecargar un generador en exceso de su capacidad clasificada de vatiaje puede resultar en da5o al generador y a los dispositivos el6ctricos conectados al mismo. Siga Io siguiente para prevenir sobrecarga la unidad. • Algunos motores ek_ctricos, tales como los de tipo de inducci6n, requieren como dos veces y media rnds de vatios de potancia para arrancar que para funcionar. Esta sobracarga momentanea de enorgta dura solarnente por unos pocos segundos cuando se arrancan dichos motores. Cerci6rese de dar tiompo para este vatiajo alto do arranquo cuando se eligen los aparatos elt_ctricos para conectar a sus _.enerador. Primero calcule los vatios que se neces=tan para arrancar el motor rods grande. Agregue a esa cifra los vaUos de funcionamiento de todas las otras cargas conectadas. • La GUIA a continuaci6n se provee para asistido en determinar cuantas piezas su ganerador puede operar al mismo tiempo. Sume el vatiaje total de todos los aparatos que se van a conectar al mismo Uempo. Este total NO debe sor mayor que la capacidad de vatiaje del generador. El vatiaje nominal de las luces pueden tomarse de las bombillas eldctricas. El vatiaje nominal de las herramientas, electrodomdsticos y rnotoros pueden usualmenta encontrarse en una placa de datos o calcomania pegada en el aparato. GUIAS DE REFERENCIA DEL VATIAJE FUNCIONAMIENTO VATIOS Aire Acondicionado (12,000 Btu) .............................. 1700 Cargador de Bater'_a(20 amp) ..................................... 500 Recortadora Razante ................................................... 450 1000 Llave de Impacto ......................................................... 500 1200 *Bomba de Chorro ..................................................... 800 800 a 1000 Segadora de C_sped ................................................. 1200 Arenador de Correa (3") ........................................... Sierra de Cadena ...................................................... Sierra Circular (6-12/') ............................ FUNCIONAMIENTO VATIOS Cafetora .................................................................... 1000 *Compresor 2000 (1 HP) ................................................ *Compresor (3/4 HP) ................................................ Rizador de Pelo ................................................. 1800 700 *Congolador ................................................................ 500 Arenador do Disco (9") .............................................. 1200 Recortadora de Bordes ............................................... 500 Bombillo .................................................................... 100 Homo Micro Ondas ...................................................... 700 *Enfriadora de Leche ................................................. 1100 Quemador de Aceite del Homo ................................... 300 Calentador de Ambiente de Aceite Quemado ( 140,000 Btu) .............................................................. Calentador de Ambiente de Aceite Quemado (30,000 Btu) .......................................................... 400 150 Pistola Eldctdca de Clavos .................................. 1200 Cocina Eldctnca (un elemento) ............................... 1500 Atom=zador do Pmtura, Sin Aire (de mano) ................. 150 Sarten Eldctnco ................................................... 1250 Rad=o ................................................................. *Ventilador de Homo (1/3 HP) ........................ 1200 *Refngerador ............................................................... Secador de Pelo ............................................ 1200 Taladro de Mano (1 ") ............................................... 1100 Taladro de Mano (1/2") .............................. 750 a 1000 Taladro de Mano (3/8") ............................................ 500 *Atomizador de Pmtura, Sm Aira (1/3 HP) ................... 600 50 a 200 * Asigne 2-1/2 veces la cantidad de vatios de la lista para arrancar estos aparatos. Rec=piente de Cocci6n Lenta200 600 MAINTENIMIENTO RECOMENDACIONES GENERALES El Propietado/Operador es responsable de asegurarse que todos los trabajce de mantenimiento pedddicos sean terminados a tiempo; que todos Ice problemas sean corregidos; y que la unidad se mantenga limpia y almacenade apropiadamente. Nunca opera un genarador dafiado o defectuosos. Siga las recomendacionas de la tabla de RECOMENDACIONES DE SERVICIO. C0mo Camblar el Ace#e: Cambie el aceite despuds de las pdmeras ocho horas de operaci6n. Carnbie el aceite cade 50 horas de aqut en adelante. Si se estd usando el ganerador bajo condiciones de suciedad o polvo, o en clima extremadamente caliente, cambie el aceite con rnds frecuencia. Cambie el aceite mientras el motor estd todav'sacaliente despul_s de haber funcionado, de la siguiente manera: PRECAUCION: I _IL _k coloquelo donde no entre an contacto con la buJla PRECAUCION: Desconec_ el cable de la buJla y I antes de trabajar en su generador. MANTENIMIENTO DEL GENERADOR • El mantenimiento del generador consiste en conservar la unided limpia y seca. Opera y almacene la unidad an un ambiente limpio y seco donde no serd axpuesta al polvo, suciedad, humedad o vapores corrosivos. Las ranuras del aim de enfriamianto del ganerador no deben estar tapadas con nieve, hojas, o cualquiar otro material extrafio. Desconecte el cable de la bujfa y I =mperelodelabujfa. Sigaesteprocedlmientocada _loU realize manten mientos en el motor o gen- Limpie el drea alrededor del talx_n drenaje del aceite, quite el tap6n (Rgura 11)y drene el aceite completamente an un rec=piente adecuado. Coloque Revise frecuentementa la limpieza del generadory Iimpielo cuando est6 con polvo, sucio, con aceite, humedad, o cuando otras substancias extrafias sean visibles en su superficie exterior. NOTA: NO recomendamce utilizar la manguera del jardin para limpiar el ganerador. El agua puede entrar al sistema de combustible del motor y causar problemas. Ademds, si el agua entra al genarador a trav6s de las ranuras dal aira de enfriamianto, parte del agua serd retenida en los huecce y desquabrajaduras del aislamiento del devanado del rotor y el estator. La acumulaci6n de agua y suciedad en los devanados internos dal generador eventualmente disminuird la resistencia al aislamiento de esos devanados. PARA LIMPIAR Utilice un patio hOmedo para dejar limpias las superficies extenores. • Puede utilizar un cepillo de cerdas suaves para recoger la suciedad y los restos sueltos. • Pueda ser utilizada una aspiradora para recoger la suciedad y las particulas. • Puede utilizar aira a baja presi6n (no exceder de 25 psi) para soplar la suciedad. Inspeccione las ranuras del aire de enfriammiento del generador. Estas aperturas se deben mantener limpras y sin obstrucciones. ,_ • Cuando el aceite ha sido drenado, instale y apriete el tap6n de drenaje del aceite. • Quite el tap_n de drenaje del aceite meta un embudo de Ilendado limpio an la abertura de tap6n. Llene el critter del motor con el aceite recomandado hasta que el nivel del aceite Ilegua al punto de rebose. No liana axcesivamente por encima del punto de rebose. Se requieren unos 720ml. VIERTAL LENTAMIENTE. • Cuando el cdrter del motor se Ilena hasta el nivel adecuado, instale y apriete el tap(_n de Ilenado del aceite. EL GENERADOR: • I FIG. ll JETO O HERRAMIENTA A TRAVES DE LAS I RANURAS DE AIRE DE ENFRIAMIENTO AUN Sl EL J MOTOR NO ESTA EN FUNClONAMIENTO. PUEDE I PRECAUCION: INSERTE NINGUN PEROB-I OCURRIR DAI_IONUNCA A LA UNIDAD O LESION SONAL. MANTENIMIENTO DEL MOTOR C6mo Examinar el Nlvel del Aceite: V6ase ANTES DE ARRANCAR EL MOTOR en la Pagina 3 para la informaci6n sobre c6mo examinar el nivel del aceite. El nivel del aceite deba axaminarse antes de cada uso o por Io mence cada ocho horas de operaci6n. Mantenga el nivel del aceite bien servido. Servicio para el Depurador de Aim: Su motor no funcionar& adecuadamente y se puede dafiar si Io hace funcionar usando un depurador de aire sucio. Limpie o reemplace el filtro de papel de depurador de aim una vez cada 25 horas de operaci6n o una vez al afio, Io que primero que tenga lugar (Figura 12 en los Pagina 11). Limpie o reemplace mds a menudo si se opera bajo condiclones polvorientas o sucias. Limpie el pra-filtro de espuma cada 25 horas de funcionamiento o antes bajo condiciones polvorientas. J _k sin tener Instalado el sistema cornpleto del depu- J PRECAUCION: Nunca haga funclonar esta unklad ] rador de aire en el motor. Esto puede resultar en I un degaste prematuro del motor. Para limpiar o reemplazar el pre-filtro de espuma: • Quite la cubierta del depurador de aire, luego el pre-filtro espuma. MANTENIMIENTO REEMPLAZO DE LA BUJ|A Cambie la bujia cada 100 horas de operack_ o una vez el ai_o, Io que pdmero tenga lugar. Esto ayudard a que el motor arranque rnds fdcilmente y a que funcione mejor. Reemplace con una bujia Champion RC12YC o un tipo equivalente. Establezca la separaci6n de los electrodos de la bujia a 0.76mm. PRE-FILTRO LIMPIEZA DE LA MALLA DEL APAGACHISPAS El silenciador de escape del motor tiene una malla de apagachispas. Inspeccione y limpie la malla cada 100 horas de operaci6n o una vez al afio, Io que primero tenga lugar. FILTRO DE PAPEI FIG. 12 • • A Limpie el pre-filtro en agua con jab_n. Exprima el pre-limpiador en saco en un trapo mojado (NO TUERZA). Sature el pre-limpiador en aceite de motor limpio y luego arrolle el pre-filtro en un trapo seco limpio para extraer el exceso de aceite (NO TUERZA). Limpie la cubierta del depurador de aire antes de instalado. Para limpiar o reemplazar el filtro de aire del papel: • Quite la cubierta del depurador de aire luego quite el pre-f tro de espuma (hdgale servicio si fuera necesario) y quite el filtro de papel. • Limpie el filtro de aire golp_andolo suavemente en una superficie s61ida. Si el filtro estd demasiado sucio, reempldcelo con uno nuevo. Bote el filtro viejo en forma apropiada. • ClADOR ANTES DE TRABAJAR EN EL NOI TOQUE UN SILENCIADOR O MOTOR CAUENTES I ADVERTENCIA: QUE SE ENFRIE EL SILF.NYA QUE PUEDENDEJE CAUSAR QUEMADURA$ $EV- I] ERAS. I NOTA: Si usa el generador en cualquier terreno descuidade cubierto de bosques, matorral o cdsped, debe tener un apagachispas.El pmpietario/operaderdebe mantener el apagachispas en buenas condiciones. Limpie e inspeccione el apagachispas de la siguente manera: • Para quitar la pantalla tdrmica del silenciador (Fig. 14), quite los nueve tormillos que conectan la pantalla al silenciador. • Quite los cuatro tornillos que unen la malla de ape.qachispas. MALLADE APAGACHISPAS Limpie la cubierta del depurador de aim luego meta el pre-filtro en la cubierta. Seguidamente meta el filtro de papel nuevo en la cubierta para sostener el pre-filtro en su lugar y ensamble todos 6stos en la base del depurado de aire. REAJUSTE DEL PAR LOS PERNOS DE CA- BEZAL SILENCIADOR Tras las primeras 50 horas de funcionamiento, reajustar el par de los pemos de cabezal. deberd • Par-- 4,0 kg.-m (50 libras-pie) • La secuencia del par es la siguiente: A, B, C, D, E (patron de comienzo). Ver la Figura 13. PANTALLA TERMICA D B FIG. 14 E C FIG. 13 10 • Inspeccione la malla y reempldcela si estd desgastada pe_forada o de cualquier manera averiada. NO USE una malla defectuosa. Si la malla no estd dar3ada, limpiela con un solvente comemial. • Vuelva a unir la malla y la pantalla t_rmica. SERVIClO Y AJUSTES VELOCIDAD DEL MOTOR PRECAUCION: La velocided del motor fue ajustada adecuademente en la fdbdca y no debe requerir rnds ajustes. No tmte de cambiar la velocidad del motor. Si usted cree que el motor estd funcionando demasiado rdpido o demasiado despacio, Ileve su generador al centro de servicio autorizado para reparaci6n y ajuste. EL CAMBIO DE LA VELOCIDAD REGULADA DEL MOTOR CANCELARA LA GARANTIA DEL MOTOR. I.as velocidades bajas del motor imponen una carga pesade en el motor cuando no haya sufldente energ_a del motor a la dispoelci6n y puede acortar la durac_)n del motor. • El generador suplird frecuencia y voltaje CA nominales correctos solamente a la velocidad apropiada. AIgunos dispositivos el6ctricos conectaclos podrlan dei_arse con una COMO AJUSTAR EL CARBURADOR El carburador de su generador es ajuste et el manufacturer. NUNCA AJUSTE EL CARBURADOR o cancelara la garantia del sistema de control de emisiones. El rendimiento del motor puede ser afectado en altitudes por encima de 5,000 pies. Si piensa que su carburador necesita ajuste viste a su distribuidor de Sen_icio Generac. Su generador funciona a una velocidad constante. Esta velocidad de funcionamiento constante se mantiene por un regulador mecdnico, de tipo contmpeso, de velocidad fija. NO trate de ajustar el ajuste do la velocidad regulada por las sJguientes razones: - • Las velocidades de motor altas son peligrosas y aumentan el riesgo de darK)s personales o dafios al equipo. RECOMENDAClONES INTERVALO DE SERVIClO DE OPERACION I POR HORA TRABAJO DE MANTENIMIENTO oCADADIARLMENTE8 HORAS CADA 25 HORAS 1. Revise el nivel de aceite. CADA 50 HORAS CADAHoRAS100 X 2. Cambie el aceite del motor. 3. Cambie el filtro del aceite. 4. De servicioal depurador de aire. 5. Umpie la Malla del Apagachispas 6. Reemplace la bujta. 7. Reemplace el filtrode combustibleen I'mea. 8. Prepdrelo para almacenaje.** "*Prepare la unidad para almacenaje si esta permanece sin funcionar por mds de 30 d'las. NOTA 1: Cambie el aceite despu6s de las primeras 8 horas de operaci6n, despu6s cada 50 horas. Cada 25 horas si. funciona bajo carga pesada o altas temperaturas ambientes. NOTA 2: Limpie mds frecuentemente bajo condiciones polvorientas o cuando est6n presentes residuos aerotransportados. 1! ALMACENAJE El genemdor debe arrancarso por Io menos una vez carla slete orbs y dejarlo funcionar pot Io menos 30 minutos. Si esto no so puede hacer y usted debe aimacenar la unidad por mds de 30 dlas, use la informacibn siguiente como una guta para prepararlo el almacenamiento. • I ADVERTENClA: NUNCA ALMACENE EL MOTOR CON COMBUSITIBLE EN ELTANQUE DENTRO DE UN EDIFIClO O AREAS ENCERRADAS, MAL VEN- • _ PRECAUCION: Evltl el rock:) deed• lentament_ el mguJero de Is bu|[a ¢uando so mmmca el motor Instale la bujia. No conecte el aiambre de la bujia. • Limpie la suciedad, el aceite y la graso del cilindro, la cabeza del cilindro, las aietas, la caja del ventilador, la malla giratoria y el drea del silenciador. Generador: TILADAS, EN DONDE VAPORES PUEDEN ALCANZAR UNA CHISPA DE LLAMA VIVA O LUZ DE: PILOTO COMO EN UN HORNO, CALENTADOR DE AGUA, SECADOR DE ROPA O UN HORNO DE GAS. Motor:. • Quite la bujia y vacle como 15ml del aceite del motor en el cilindro. Arranque lentarnente 10am distribuir el aceite. Haga funcionar el motor por unos cinco minutos para calentado. ,, Umpie el generador como so expuso a grandes msgos en la Pdglna 5 ("Chino Limpiar el Generador'). • Examine para ver si las ranuras de aim refrigerants y las aberturas en el generador estdn abiertas y sin obstrucciones. OVal Sugemncias tara AlmaCenllJe: • No almacene gasolina de una estacibn a otra. NOTA: Si us6 "gasohol,"drene tanque de combustible, luego haga funcionar el motor hasta que el motorse pare, pot falta de combustible. ADVERTENClA: DRENE EL COMBUSTIBLE EN I UN REClPIENTE APROPIADO AL AIRE MBRE, LE- Reemplace la gasolina si comienza a oxidarse. [] herrumbre y/o/a suciedad en su gasolina pueden causar problemas cuando so usa con esta unidad. JOS EL MOTOR DE UNAESTE LLAMA FRIO. VIVA. CERClORESE DE QUE Almacene en un drea limpia y seca. Mientras el motor estd todav'ta caliente, drene el aceite del cdrter. Vuelva a Ilenar con aceite fresco. Vdase ESPECIFICACIONES en la Pdgina 1 para las recomendaciones de aceite. 12 PUNTOS DEI. DIAGNOSTICOS DE AVERIAS PROBLEMA El motorest_ funclonandopero no existe saiida de CA disponsible. CAUSA CORRECCION 1, El interruptorautomdticode circuito. est_ abierto. 1. ReposJdoneel Interruuptor. 2. Averta en el generador 2. Contacte el Departmentode ServlctoSears. 3. Conexi6n real o de_ de cables. El motorlunciona bien sin carga pen) "lunciona mar cuando se me contectancargas. del juego 4, El disposittvoconectado estd defiado. 4. Conecte otro dispositJvoque e616 buenes condiclones. 1. Codo circuitoen una de las cargas conectadas. 2. Velocidad del motor es muy lenta. 1. Desco_cte la ca_gaetdclflca en. corto. 2. Contacte el Deparl_nontode Sendelo Seara. 3. El generador estd sobmcarga. 3. Vea =NoSobrecar_ el Generador en la Pagina 7. 4. Contacto el Departmento de Servicio Sears. 4. Circuito del generador en code. El motorno se enciende; o se enblende y fundona mal. 1. InterrupterRun/Stop poscioando en STOP. I. Coloque del interrupteren RUN. 2. Depurador de air sucio. 2. Limpie o reemplace e_depurader de aim. 3. Ll_)netoco(i combustiblefresco. 3. Sin gasolina. 4. Gasolina vieja. 5. El cable de la bujia no estd en males la bujla. 6. Bujia defectuosa. 7. Agua en la gasolina. 8. Sobmcebado. 9. Mezcla de combustible excesivamente dca. El motor se apaga durante el funcionamiento Le falta fuerza al motor. 4. Drene el tanque de gasolina; Ildnolocon combustiblefresco. 5. Conecte el cable a la buj'la. 6. Reemplace la bujta. 7. Drene el tanque de gasolina;. Ildnelo con combustiblefresco. 8. Abm por completo el cebador y haga girar el motor. 9.. Contacte el Deparlmento de Servicio Sears. 10. La vdlvula de entrada estd atascada Servicio Sears. 11. El motor ha perdido compresi_l. 11. Contacte el Departmento de Servicio Sears. 1. 2. 1. 2. Sin gasolina. Nivel de aceite bajo. 1. La carga es muy alta. 2. Depuradorde aim sucio. El motorcambia de dtmo 3. Revise y repare. Llene el tanque de combustible. Llene de caja del cig0ei_al al nivel apropiado. 1. Vea "No Sobrecargue el Generador" la P_tgina7. 2. Reemplace el tiltro de aira. 1. El cebador es abierto muy pronto. 1. Mueva el cebador a la posci6n intermedia hasta qus el motor funcione suavemente. 2. El carbura0or estd funcionandocon 2. Contacto el Departmento de Sen/icio Seara.. una mezcla muy dca o muy pobre 13 TUERCA EN EL I_,(X_IE OIAGRAMA ELECTRIOO O_. MOTOR GENERADOR DE CRAFTSMAN DE 4200 VATIOS CA 580.327140 PARA LISTE DE PARTES VEA LA PA GINA 15 VERSION EN INGLES Dibjuo Nro. 87407 15 REPUESTO$ GENERAl)OR DE CRAFTSMAN DE 4200 VATIOS CA 580.327140 REPUESTO$ 7O 49 5O 71 74 :_ 47 3 64 52 4 35 11 13 DETNL 14 38 16 Dibujo Nro. B2554 16 " Y " GENERADOR DE CRAFTSMAN DE 4200 VATIOS CA 580.327140 REPUESTOS PARA LISTE DE PARTES VEA LA PA GINA 17 VERSION EN INGLES 17 Dibujo Nro. 97193 CRAFTSMAN 4200 WATt DELUXE AC GENERATOR 580.327140 PARA LISTE DE PARTES VEA LA PAGINA 18 VERSION EN INGLES 18 REPAIR PARTS CRAFTSMAN 4200 WATT DELUXE AC GENERATOR 580.327140 PARA LISTE DE PARTES VEA LA PAGINA 19 VERSION EN INGLES 19 REPAIR PARTS CRAFTSMAN 4200 WATr DELUXE AC GENERATOR 580.327140 PARA LISTE DE PARTES VEA LA PAGINA 20 VERSION EN INGLES 2O REPAIR PARTS CRAFTSMAN 4200 WATT DELUXE AC GENERATOR 580.327140 PARA LISTE DE PARTES VEA LA PAGINA 21 VERSION EN INGLES REPAIR'PARTS NOTAS 22 NOTAS 23 GARANTIA LIMrrADA DE DOS ANO DE GENERADOR PORTATILE CRAFTSMAN SEARS garantJzaal compradororiginalque el alternadory el motorpara su generadorport_tilestar_n librosde defectos en los matedaleso la mano de obra para las piezasy el perfodoestablecidoa partirde la fecha de compraoriginal.Esta gamntfa no es tmnsfedbley se aplica dnicamentea los generadoresport_Ulesimpulsadosporel motorgarantizadoGN Seria de Seam. Consumldor* Comerclal* Altemador 2 aP,os 1 afio Motor 2 afios 1 ai_o *Nota: Para el prop6sitode esta gamntfa"Usode Consumidor"quiem deck uso dom6sticode residenciapersonalpor el compmdororiginal."UsoComemial"quiere decirtodoslos otrosusos,incluyendoalquiler,construccibn,comerciely prop&sitosqua produosnganancia.Una vez qua un generadorha experimontadouso comercial,de allf on adelenteserd consideradocomo un generadorde uso comercialpara los pmp6sitosde osta gamntfa. Durante dichoperfodode grant|a,SEARS repamrdo remplazrda su opci6n cualquierpioza la cuel, al ser exarninadepor SEARS, se encuentreque ostd defectiosabajo uso y servicionormales*°. Las baterfasde arranquono estdn garantizadas por SEARS.Todoslos costosde tranportebajo la garantfa, incluyendola devoluci6na la fdbrica si fuom necesario,serdn cargadosal compradory prepagadospor61.Esta grantfano incluyeel mantonimiantoy servicionormal no se aplica a un conjuntode generador,altemador o motor,o las plazas qua han sido sujetasa instelack_na altemci6ninadecuadadso desautodzadas, abuso, negligencia,accidentes,sobrecarga,velocidadaxossiva,mantenimiento, mpamiones o elmacenamientoinadecuados,de modoqua, an la opini6nde SEARS, afecten advorsamantesu mndimionto y confiabilidad. **Degaste Normal: Comocon todos los aparatoselE_ctdcos,los motores necesitanservicioy reemplazoped_lico para qua den buenrendimiento.Esta gamnt='ano cubrir&mpamck_n cuandoel uso normal ha agotadola duraci6nde una pieza o de un motor. No hay ningunaotra garantfaexpresada.SEARS poreste medio desconocecualquioray todas las grantfas[mplicadas, induyendoperono limitdndosea aquellasde mercantibildady adaptaci6npara un propositoparticular,an la pmpomi6n permitadapor la lay.La dumci6nde cualquiergamntl'aimplicadala cual no puede ser desconocida se limitaal perfodode teimposeg_Jnse especificaen la gamntl'aexpresada.La msponsabilidad pordaRosde consequencia,accidontaleso especialesbajo cuelquierao todas las garantl'asse excluye.Algunosestadosno permitenlimitacionassobm c0antotiempo una gamnt|a implicadadura, o la exclusfono limitaci6nde dai_osaccidentaleso de consecuenoia,de manara qua las limitacionoso exclusionosmencionadasanteriormentopuedenno aplicarpara usted.Esta gamntfa le da darechoslegales especificosy ustedtambi6npuedetenor otrosderechos,los cualesvarfan de estado a estado. Para servicio,p6ngaseen contacola instalaci6nde serviciode garantfaautorizadamds cercana de SEARS. El serviciode garantfapuede ser Ilevadoa cabo solamentepor una iostelaci6nde servicioautorizadode SEARS. Esta garantfano se aplica al serviciodado en ningunaotra instalacibn.En el momentode solicitarservicode gmntfa,se debe presentarevidanca de la fecha de compraoriginal. SEARS, ROEBUCK AND CO., D/817 WA, Hoffman Estates, IL 60179 24 NOTAS 25
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.2 Linearized : No Page Count : 56 Page Layout : SinglePage Page Mode : UseNone Producer : Goby Monitor Application version 3, 2, 1, 4 Create Date : Mon Apr 02 21:28:49 2007 Author : Title : Subject :EXIF Metadata provided by EXIF.tools