Crestron Electronics CWD6894 2-Way RF Transceiver Module User Manual Manual CWD6894 Doc7180A

Crestron Electronics Inc 2-Way RF Transceiver Module Manual CWD6894 Doc7180A

Manual

Crestron CWD6894 Two-Way RF Transceiver Module Operations Guide
  This document was prepared and written by the Technical Documentation department at:   Crestron Electronics, Inc. 15 Volvo Drive Rockleigh, NJ 07647 1-888-CRESTRON   Regulatory Compliance      Federal Communications Commission (FCC) Compliance Statement This device complies with part 15 of the FCC Rules.  Operation is subject to the following conditions: (1) This device may not cause harmful interference and (2) this device must accept any interference received, including interference that may cause undesired operation.  CAUTION:  Changes or modifications not expressly approved by the manufacturer responsible for compliance could void the user’s authority to operate the equipment.  NOTE: This equipment has been tested and found to comply with the limits for a Class B device, pursuant to part 15 of the FCC Rules.  These limits are designed to provide reasonable protection against harmful interference in a residential installation.  This equipment generates, uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.  However, there is no guarantee that interference will not occur in a particular installation.  If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more if the following measures:   Reorient or relocate the receiving antenna  Increase the separation between the equipment and receiver  Connect the equipment into an outlet on a circuit different from that to which the receiver is connected  Consult the dealer or an experienced radio/TV technician for help       Industry Canada (IC) Compliance Statement Operation is subject of the following two conditions: 1. This device may not cause interference, and 2. This device must accept any interference, including interference that may cause undesired operation of the device.       To satisfy RF exposure requirements, this device and its antenna must operate with a separation distance of at least 20 centimeters from all persons and must not be colocated or operating in conjunction with any other antenna or transmitter.          All brand names, product names and trademarks are the property of their respective owners. ©2011 Crestron Electronics, Inc.
Crestron CWD6894  Two-Way RF Transceiver Module Operations Guide - DOC. 7180A  Contents    i Contents Two-Way RF Transceiver Module: CWD6922 .............................................. 1Functions and Features .............................................................................................................. 1Specifications ............................................................................................................................. 2Physical Description .................................................................................................................. 2Setup .......................................................................................................................................... 5Labeling ..................................................................................................................................... 5Documentation ........................................................................................................................... 6
Crestron CWD6894  Two-Way RF Transceiver Module Operations Guide - DOC. 7180A  Two-Way RF Transceiver Module: CWD6894    1  2.4 GHz frequency band, IEEE 802.15.4 specification  Range from 3 feet to 550 ft.  Operates on one of sixteen available channels to establish optimal signal quality Two-Way RF Transceiver Module: CWD6894 Functions and Features The CWD6894 (hereafter referred to as “module”) is a two-way radio frequency (RF) module that utilizes the 2.4 GHz frequency band to communicate with other devices. The module operates according to the IEEE 802.15.4 specification and can be configured to minimize the possibility of interference with other devices.  The module receives RF signals from one or more Crestron devices and can transmit these signals over the air for further processing (depending on the application).  Functional Summary
Two-Way RF Transceiver Module  Crestron CWD6894 2    Two-Way RF Transceiver Module: CWD6894  Operations Guide - DOC. 7180A   Specifications The table below is a summary of specifications for the CWD6894.  Specifications of the CWD6894-1 & -2 SPECIFICATION DETAILS Operating Frequency  2400 MHz to 2483.5 MHz (802.15.4 compliant) Operating Ranges*  Minimum Distance   Maximum Distance Outdoors    (without repeater device)  3 ft 550 ft Available Channels  16 (numbered 11 through 26 per 802.15.4)   Power Requirements  0.66 Watts (3.3VDC @ 0.20A) Dimensions (CWD6894-1)  Width:  1.000 in (2.54 cm) Height:  1.075 in (2.73 cm) Depth:  0.313 in (0.8 cm) Dimensions (CWD6894-2)  Width:  1.000 in (2.54 cm) Height:  1.075 in (2.73 cm) Depth:  0.217 in (0.55 cm) Antenna (CWD6894-1)  Gain:  2.0±0.5 dBi max. Type:  Sleeve Dipole Antenna Frequency: 2.4GHz to 2.5 GHz Connector  Type: SMA Plug Reverse Polarity Connector with ¼-36 UNS2B Screw Antenna (CWD6894-2)  Max. Gain: 1.8 dBi  Average Gain: -1.9 dBi  Type: Intended for SMD Mounting  Frequency: 2.4GHz to 2.5 GHz  *  The location and orientation of the module are important factors in the RF performance. With the unit located outside of any metal enclosures, the antenna is adjusted to achieve the best range. The range is dependent on its placement and the building in which it is used. The construction of the building, obstructions, and RF interference from other devices are factors determining the effective range of the unit. To prevent unit-to-unit RF interference, multiple modules operating at the same frequencies should not be installed within 3-5 feet of each other. Physical Description The module, shown after this paragraph, consists of various components attached to a printed circuit board. It is designed with two types of antennas: a dipole antenna (refers to CWD6894-1) and a SMD antenna (refers to CWD6894-2).  An antenna port is located at the edge of the circuit board.   For the CWD6894-1, the antenna port is equipped with a SMA reverse polarity female connector.  For the CWD6894-2, the antenna port is equipped with an U.FL connector.
Crestron CWD6894  Two-Way RF Transceiver Module Operations Guide - DOC. 7180A  Two-Way RF Transceiver Module: CWD6894    3 Physical View of CWD6894-1  CWD6894-1 Detail Views            SIDE               TOP      TOP VIEW. THROUGH BOARD     (ACTUAL SIZE)
Two-Way RF Transceiver Module  Crestron CWD6894 4    Two-Way RF Transceiver Module: CWD6894  Operations Guide - DOC. 7180A   Physical View of CWD6894-2  CWD6894-2 Detail Views            SIDE               TOP      TOP VIEW. THROUGH BOARD     (ACTUAL SIZE)
Crestron CWD6894  Two-Way RF Transceiver Module Operations Guide - DOC. 7180A  Two-Way RF Transceiver Module: CWD6894    5 Power/I-O Edge connectors provide power to the module as well as the communication between the module and wired devices. Refer to the following table for pin assignments of the module interface connector. Power/I-O Pinout Signals Pin #  Signal  Pin #  Signal  Pin #  Signal  Pin #  Signal 1 GND1  7 GPIO1  13  SPICLK  19 GPIO6 2  RXEN 8  RST_N  14  SPI_MOSI  20  GPIO7 3 TXEN 9 PAEN 15 SPI_MISO 21 GND8 4  GPIO4  10  RXTXEN  16  SPI_CE_N  22  GND9 5  GPIO3  11 ATTN_N  17 IRQ_N  23 VCC (+3.3VDC) 6  GPIO2  12  CLKO  18  GPIO5  24 GND7 Setup Refer to the hookup diagram below, which shows the connections made to the module. Complete the connections in any order. NOTE: To prevent unit-to-unit RF interference, multiple modules operating at the same frequencies should not be installed within three to five feet of each other. Hardware Hookup
Two-Way RF Transceiver Module  Crestron CWD6894 6    Two-Way RF Transceiver Module: CWD6894  Operations Guide - DOC. 7180A   Labeling If the FCC identification number is not visible when the module is installed inside another device, then the outside of the device into which the module is installed must also display a label referring to the enclosed module.  This exterior label can use wording such as the following: “Contains Transmitter Module FCC ID: EROCWD6894” or “Contains FCC ID: EROCWD6894.”  Any similar wording that expresses the same meaning may be used. Documentation The OEM integrator has to be aware not to provide information to the end user regarding how to install or remove this RF module in the users manual of the end product.  The users manual for OEM integrators must include the following information in a prominent location  “IMPORTANT NOTE: To comply with FCC RF exposure compliance requirements, the antenna used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter.”
Crestron CWD6894  Two-Way RF Transceiver Module Operations Guide - DOC. 7180A  Two-Way RF Transceiver Module: CWD6894    7                                                                 This page is intentionally left blank.
 Crestron Electronics, Inc.  Operations Guide – DOC. 7180A  15 Volvo Drive   Rockleigh, NJ 07647   Tel: 888.CRESTRON 02.11 Fax: 201.767.7576  Specifications subject to www.crestron.com  change without notice.

Navigation menu