Crestron Electronics HR310 Zigbee Handheld Remote User Manual DO Guide HR 310

Crestron Electronics Inc Zigbee Handheld Remote DO Guide HR 310

User manual

DO GUIDEHR-310 Handheld RemoteJoining an inNET EX Network1. Press the ACQUIRE button on the inNET EX gateway to enter Acquire mode, or enterAcquire mode from Crestron Toolbox™ software. For more information, refer to theCEN-GWEXER Installation Guide (Doc. 7723), the DIN-AP3MEX Installation Guide (Doc.7492), or the MC3 DO Guide (Doc. 7774) at www.crestron.com/manuals.NOTE:  In an environment where there are multiple gateways installed, only one gatewayshould be placed in Acquire mode at any time.2. Quickly press the      (Home) button on the HR-310 three times, and then press and hold the      button (press, press, press, press + hold) until the backlight on the remote blinks once. (This process can take up to 10 seconds.)3. Release the      button to start the acquire process. The backlight blinks slowly to show that the remote is actively scanning the inNET EX network.4. Conrm the status of the acquire process: • If the HR-310 is acquired by the inNET EX network, the backlight turns on for veseconds. • If the HR-310 is not acquired by the inNET EX network, the backlight rapidly blinks.Press the      button to cancel the acquire process. Ensure the gateway is in Acquiremode and that the HR-310 is in range before attempting the acquire process again.5. After the acquire process is complete, remove the gateway from Acquire mode asdescribed by the gateway’s documentation.NOTE:  Firmware updates can only be performed by connecting the HR-310 to Crestron Toolbox via USB. Remove the battery cover on the rear of the HR-310 to locate the micro USB port, and then connect the remote to the computer using a micro USB to USB A cable (not included). For more information on performing rmware updates in Crestron Toolbox, refer to the embedded Crestron Toolbox help le.Leaving an inNET EX NetworkTo leave an inNET EX network, put the HR-310 into Acquire mode as described in “Joining an inNET EX Network” when no gateway has been placed in Acquire mode.DO Install the Battery PackThe Crestron® HR-310 ships with three AAA alkaline batteries that must be installed prior to operating the remote. Use the following procedure to install the battery pack.1. Locate the battery cover on the rear of the HR-310. Gently push on the battery cover whilesliding it down and away from the remote until the tabs connecting the cover to the remotedisengage.2. Install the included AAA batteries as shown in the illustration following step 3. Observe thecorrect polarity when inserting the batteries into the compartment.3. Reattach the battery cover by aligning the tabs on the top and bottom of the cover withtheir respective slots on the bottom of the HR-310, and then gently push the cover upwarduntil the tabs snap into place.DO Acquire the RemoteThe HR-310 must be acquired by an inNET EX® wireless gateway or by a control system with a  built-in inNET EX gateway (both not included) before it can be used with a Crestron control system. Supported devices with inNET EX gateways currently include the Crestron CEN-GWEXER, DIN-AP3MEX, and MC3. Use the procedures outlined in this section to join or leave an inNET EX network and to verify communications between the device and the control system.DO Check the BoxQTY PRODUCT PART NUM.1Batteries, AAA Alkaline, x3 2022558Battery coverAAA batteries (3):positive (+) terminalsHR-310(rear view)PRELIMINARY
DO GUIDE DOC. 8228A (2049525) 11.17Specications subject to change without notice.Verifying Communication StatusTo check the communication status of the HR-310, quickly press the      button three times, and then press and hold the      button for up to two seconds. The backlight blinks to indicate the current communication status as described in the table below. DO Set the Device RFIDIf required, use the following procedure to set the RFID (radio-frequency identication) of the  HR-310.NOTE:  The HR-310 RFID is set to “01” by default.NOTE:  The HR-310 must be kept awake to maintain communications while setting the device RFID via a wireless connection. After completeing the below procedure, press any button on the HR-310 to wake the remote so that it receives the change ID command from the gateway.1.  Ensure that the HR-310 has been acquired to the inNET EX wireless gateway as described in the “DO Acquire the Remote” section above.2.  Open Crestron Toolbox and select the InNetEx Diagnostic Tool. The tool scans the inNET EX network for the wireless gateway and all acquired devices.3.  Once the gateway has been discovered, locate the HR-310 in the Connected Devices table. 4.  Right click on the HR-310’s entry in the Connected Devices table, and then click inNET(EX) ID.5.  Select a new RFID from the provided drop-down menu, and then click Apply to send the new RFID to the device. Click OK to exit.Alternatively, the device RFID can also be set through the Text Console tool in Crestron Toolbox. Remove the battery cover on the rear of the HR-310 to locate the micro USB port, and then connect the remote to the computer using a micro USB to USB A cable. Open the Text Console tool in Crestron Toolbox, and then issue the M N ETID  [x x]  command, where xx is the desired RFID. The HR-310 remains awake when connected to a USB host.DO Customize the Hard ButtonsThe HR-310 ships with a default set of nine congurable hard buttons installed. Custom-engraved buttons can be created and ordered using Crestron Studio® software to replace the default button set. For more information on installing the custom hard buttons, refer to the HR-310-BTN Installation Guide (Doc. 8224) at www.crestron.com/manuals.DO Learn MoreVisit the website for additional information and the latest rmware updates. To learn more about this product, use a QR reader application on your mobile device to scan the QR image.Crestron Electronics 15 Volvo Drive, Rockleigh, NJ 07647 888.CRESTRON | www.crestron.comAs of the date of manufacture, the product has been tested and found to comply with specications for CE marking.  Federal Communications Commission (FCC) Compliance Statement This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.CAUTION:  Changes or modications not expressly approved by the manufacturer responsible for compliance could void the user’s authority to operate the equipment.NOTE:  This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help.Industry Canada (IC) Compliance Statement CAN ICES-3(B)/NMB-3(B)This equipment should be installed and operated with a minimum distance 20cm between the radiator and your body Cet équipement doit être installé et utilisé à une distance minimale de 20 cm entre le radiateur  et votre corps.This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio exempts de licence. L’exploitation est autorisée aux deux conditions suivantes : (1) l’appareil ne doit pas produire de brouillage, et (2) l’utilisateur de l’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en compromettre le fonctionnement.Crestron product development software is licensed to Crestron dealers and Crestron Service Providers (CSPs) under a limited non-exclusive, non-transferable Software Development Tools License Agreement. Crestron product operating system software is licensed to Crestron dealers, CSPs, and end-users under a separate End-User License Agreement. Both of these Agreements can be found on the Crestron website at www.crestron.com/legal/software_license_agreement.The specic patents that cover Crestron products are listed at www.crestron.com/legal/patents.The product warranty can be found at www.crestron.com/legal/sales-terms-conditions-warranties.Certain Crestron products contain open source software. For specic information, visit www.crestron.com/legal/open-source-software. Crestron, the Crestron logo, Crestron Studio, Crestron Toolbox, inNET EX, and the inNET EX logo are either trademarks or registered trademarks of Crestron Electronics, Inc. in the United States and/or other countries. Other trademarks, registered trademarks, and trade names may be used in this document to refer to either the entities claiming the marks and names or their products. Crestron disclaims any proprietary interest in the marks and names of others. Crestron is not responsible for errors in typography or photography.This document was written by the Technical Publications department at Crestron. ©2017 Crestron Electronics, Inc.BACKLIGHT BEHAVIOR COMMUNICATION STATUSThe backlight turns on for ve seconds. The HR-310 is communicating with the control system.The backlight blinks three times.The HR-310 is communicating with the control system, but the gateway is not communicating with the control system.The backlight blinks twice. The HR-310 was previously joined to the network but is no longer communicating with the gateway.The backlight blinks once. The HR-310 is not joined to the network.PRELIMINARY

Navigation menu