Cross Match Technologies SENTRY1 Mobile Biometric Device User Manual Sentry A4

Cross Match Tecnologies, Inc. Mobile Biometric Device Sentry A4

Users Manual

Download: Cross Match Technologies SENTRY1 Mobile Biometric Device User Manual Sentry  A4
Mirror Download [FCC.gov]Cross Match Technologies SENTRY1 Mobile Biometric Device User Manual Sentry  A4
Document ID2576957
Application IDXFn4LkG5mbp6oJRjobI7AA==
Document DescriptionUsers Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize257.63kB (3220401 bits)
Date Submitted2015-04-07 00:00:00
Date Available2015-04-07 00:00:00
Creation Date2015-04-06 15:58:27
Producing SoftwareAcrobat Distiller 10.1.13 (Windows)
Document Lastmod2015-04-06 16:27:42
Document TitleSentry (A4).book
Document CreatorFrameMaker 12.0
Document Author: linda.garneau

Crossmatch™
®
Verifier Sentry
Operator Manual
Part Number 870391 V1.0
© Copyright, 2014 Cross Match Technologies, Inc. All rights reserved. Specifications are subject to change without prior notice.
Verifier is a registered trademark, and Crossmatch is a trademark, of Cross Match Technologies, Inc. All other trademarks are the
property of their respective owners. No portion of this guide may be reproduced in any form without the express written permission
of Cross Match Technologies, Inc.
Contents
Introduction
H o w t h i s b o o k i s a r r a n g e d . . . . . . . . .. . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . .. . . . . . . . . . . .
S t a n d a r d s . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . .. . . . . . . . . . . .
G l o s s a r y . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . .. . . . . . . . . . . .
S p e c i f ic a t i o n s f or t h e S e n t r y . . . . .. . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . .. . . . . . . . . . . .
A c c e s s o r i e s f o r t h e S e n t r y . . . . . . . .. . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . .. . . . . . . . . . . .
F C C S t at e m e n t . . . . . . . . .. . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . .. . . . . . . . . . . .
I n d u s t r y C a n a d a . . . . . .. . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . .. . . . . . . . . . . .
C e r t i f i c a t i o n i d e n t i f i e r s f o r w i r e l e s s m o d u l e s . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . .. . . . . . . . . . . .
R e c y c l i n g i n f o r m a t i on . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . .. . . . . . . . . . . .
B a t t e r y d i s p o s a l .. . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . .. . . . . . . . . . . . .
W E E E D i r e c t i v e . . . . . . . .. . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . .. . . . . . . . . . . .
Description
The
The
The
The
The
The
f r o n t o f t h e S e n t r y . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . .. . . . . . . . . . . . 6
l e f t s i d e o f t h e S e n t r y . . . . . . . . .. . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . .. . . . . . . . . . . . 7
r i g h t s i d e o f t h e S e n t r y . . . . . . .. . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . .. . . . . . . . . . . . 8
b a c k o f t h e S e n t r y . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . .. . . . . . . . . . . . 9
t o p o f t h e S e n t r y . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . .. . . . . . . . . . . 1 0
b o t t o m o f t h e S e n t r y . . . . . . . . . . .. . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . .. . . . . . . . . . . 1 0
Use the Sentry
S t a r t t h e S e n t r y . . . . . .. . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . .. . . . . . . . . . .
S t o p t h e S e n t r y . . . . . . .. . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . .. . . . . . . . . . .
S c a n a C o n t a c t C a r d .. . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . .. . . . . . . . . . .
S c a n a C o n t a c t le s s C a r d . . . . . . . . . . . .. . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . .. . . . . . . . . . .
R e a d a n e P a s s p o r t . . .. . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . .. . . . . . . . . . .
C a p t u r e a n d v e r i f y t h e b i o m e t r i c s . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . .. . . . . . . . . . .
C a p t u r e a p h o t o g r a p h . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . .. . . . . . . . . . .
R e a d a b a r c o d e . . . . . . .. . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . .. . . . . . . . . . .
11
12
13
14
16
17
18
18
Maintenance
R e m o v e t h e b a t t e r y . .. . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . .. . . . . . . . . . .
I n s t a l l t h e b a t t e r y . . .. . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . .. . . . . . . . . . .
I n s e r t a S A M c a r d . . . .. . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . .. . . . . . . . . . .
R e m o v e a S A M c a r d .. . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . .. . . . . . . . . . .
I n s e r t t h e S I M c a r d . .. . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . .. . . . . . . . . . .
R e m o v e t h e S I M c ar d . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . .. . . . . . . . . . .
I n s e r t t h e M i c r o S D c ar d . . . . . . . . . . .. . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . .. . . . . . . . . . .
R e m o v e t h e M i c r o S D c a r d . . . . . . . . .. . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . .. . . . . . . . . . .
F i n d t h e P r o d u c t L a b e l . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . .. . . . . . . . . . .
R e p l a c e t h e f i n g e r p r i n t s e n s o r . . .. . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . .. . . . . . . . . . .
21
22
22
22
23
23
23
24
24
24
Customer Care
T e c h n i c a l S u p p o r t . . . .. . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . .. . . . . . . . . . . 2 5
Contents
E - m a i l . . .. . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . .. . . . . . . . . . .
T e l e p h o n e a n d f a c s i m i l e . . . . . . . . . . . .. . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . .. . . . . . . . . . .
R e t u r n a n d r e p a i r o f t h e S e n t r y . .. . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . .. . . . . . . . . . .
D e l i v e r y c o s t s . . . . . . . . .. . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . .. . . . . . . . . . .
C o n t a c t i n f o r m a t i o n .. . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . .. . . . . . . . . . .
25
25
26
26
26
Warranty
L I M I T E D W A R R A N T Y .. . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . .. . . . . . . . . . . 2 7
Index
ii
Verifier ® Sentry Operator Manual 870391 V1.0
Figures
Figure
Figure
Figure
Figure
Figure
Figure
Figure
1:
2:
3:
4:
5:
6:
7:
The
The
The
The
The
The
T he
front of the Sentry ............................................................................. 6
left side of the Sentry ........................................................................ 7
right side of the Sentry ...................................................................... 8
back of the Verifier ® Sentry ............................................................... 9
top of the Verifier ® Sentry ................................................................. 10
bottom of the Veri fi er ® Sentry ........................................................... 10
Sen try b attery com p artment (battery re moved) .................................... 21
iii
Figures
iv
Verifier ® Sentry Operator Manual 870391 V1.0
Tables
T abl e
T abl e
T abl e
T a bl e
T a bl e
T a bl e
T a bl e
T a bl e
T a bl e
T a bl e
T abl e
T abl e
T abl e
1 : Glossary ................................................................................................... 2
2 : S p e c i f i c a t i ons ........................................................................................... 2
3 : Biometric / Credential Capture .................................................................... 2
4 : A p p l i c a t i o n s .............................................................................................. 3
5 : Accessories ............................................................................................... 3
6 : The front of the Sentry ............................................................................... 6
7 : The left side of the Sentry .......................................................................... 7
8 : The right side of the Sentry ......................................................................... 8
9 : The back of the Sentry ............................................................................... 9
1 0 : The top of the Verifier ® Sentry ................................................................. 10
1 1 : The bottom of the Veri fi er ® Sentry ............................................................ 10
1 2 : Items on the Sentry desktop ..................................................................... 11
1 3 : Items in the Sentry bat tery compartment ................................................... 21
Table 10: The bottom of the Sentry
17
Tables
vi
Verifier ® Sentry Operator Manual 870391 V1.0
Introduction
H o w t h i s b o o k i s a r ra n g e d
•
•
•
•
•
“Introduction” describes this book and its contents.
“Description” describes the Verifier® Sentry and its features. You learn how to start the device.
“Use the Sentry” describes how to use the Verifier® Sentry to capture the biometric information.
“Maintenance” how to perform normal maintenance on the Verifier® Sentry.
“Customer Care” contains the information about technical assistance for the Verifier® Sentry and lists the
contact numbers for Crossmatch.
• “Warranty” contains the Crossmatch warranty for the Verifier® Sentry.
S t a n d a rd s
The following standards are used in this book:
•Bold UPPERCASE text, bold lowercase text or tilted text identify important information. Special information
can appear in a Note, Caution or Warning.
Note
A Note contains additional information. To ignore a note can cause a delay, There is no mechanical damage or personal
injury.
Caution
A Caution contains a method to prevent the loss of data or damage to equipment.
Warning
A Warning indicates that the loss of data or personal injury can occur.
Introduction
Glossary
Table 1
Glossary
Term
3G
Definition
The third generation of cellular mobile phone and data communication standards, featuring
higher bandwidth for web-based applications and video.
Note
In the Sentry, the 3G cellular modem transmits data. The Sentry does not transmit
voice.
A Crossmatch technology that captures an acceptable fingerprint without action from the user.
Auto Capture
Bluetooth
Flat fingerprint
GPS
Platen
USB
User
Wi-Fi
A short-range radio technology that makes easy the following types of communications:
• The communications between internal devices
• The communications between devices and the Internet
• The synchronization of data between internal devices and other computers
A name for a fingerprint captured with the fingertip pressed on the platen. The Sentry captures
flat fingerprints.
The Global Positioning System of satellites that can accurately find a GPS transceiver.
The surface where you put the fingers to capture the fingerprints.
The Universal Serial Bus (USB) is a standard method to connect electronic devices.
The user captures the biometric and personal information. Another name is the operator.
Wireless local area network technology using the 802.11 standard.
The Verifier Sentry can not be the access point for a Wi-Fi hotspot. One network connection
(Wi-Fi or Cellular) is allowed. When the primary connection is active, the secondary connection
is not active
Specifications for the Sentry
Table 2
Specifications
Category
Description
Main Processor
Operating System
Memory
Weight
Dimensions
Operating Temperature
Humidity Range
Power
Ruggedized standards
ARM®
External interfaces
Wireless Communications
USB-OTG (On The Go), Docking Station and Accessory.
Display
Table 3
Cortex-A9™ based iMX6 by Freescale™
Android® 4.2.2
8GB Storage + 1GB DDR RAM; Internal eMMC slot to expand memory
4lbs (630g)
7 in (208 mm) by 3.7 in (94 mm) by 1.25in (32 mm)
14°F to 122 °F (-10 °C to 50 °C)
10% to 90% non-condensing; Splash-resistant, IP65
Removable battery, 8-hour operation
MIL-STD-810G
Bluetooth® 4.0, Wireless LAN 802.11b/g/n;
Cellular Connectivity 3G
4.3 in, 800x480 WVGA display with projective capacitive touch panel
Biometric / Credential Capture
Category
Fingerprint
Camera
Description
500 ppi, FAP 30 PIV-certified single finger sensor
5MP Auto Focus, Auto Flash
Verifier® Sentry Operator Manual 870391 V1.0
Introduction
Table 3
Biometric / Credential Capture
Category
Smart Card (contact or contactless)
Bar Code Reading
ePassport
Table 4
Description
ISO / IEC 7801 (CAC, PIV, TWIC,14443-A, 14443-B, 15693, NFCIP-1,
NFCIP-2, MIFARE, FeliaCa)
1D / 2D (PDF 417, Code 39)
ICAO 9303 - MRZ, NFC
Applications
Category
SDK’s
Description
Verifier Sentry Essentials
Accessories for the Sentry
Table 5
Accessories
Accessory
Docking Station
Description
The Docking Station can charge two batteries, one in the Sentry and
one in the battery charger compartment. The docking station has one
Ethernet connector and four USB connectors.
FCC Statement
FCC ID#: Q9YSENTRY1
This device has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the
FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the
equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency
energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to
radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which
case the user will be required to correct the interference at this own expense.
Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This
device must accept any interference received, including interference that may cause undesired operation.
FCC RF exposure requirements:
Warning: Changes or modifications not expressly approved by the manufacturer, could void the user's authority to
operate the equipment.
Industry Canada
IC: 7944B_SENTRY1
This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two
conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including
interference that may cause undesired operation of the device.
“Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio exempt du licence.
L’exploitation est autorisée aux deux conditions suivantes: (1) l’appareil ne doit pas produire de brouillage, et (2)
l’utilisateur de l’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en
compromettre le fonctionnement.”
Introduction
C e r t i f i c a t i o n i d e n t i f i e r s f o r w i re l e s s m o d u l e s
Wi-Fi/Bluetooth : TiWi-BLE
FCC ID: Q9YSENTRY2
IC ID: 7944B-SENTRY2
Cellular: PHS8-P
(USA) FCC ID#: Q9YSENTRY3
(Canada) IC ID#: 7944B-SENTRY3
R e cy c l i n g i n f o r m a t i o n
Crossmatch recommends that customers dispose of their used computer hardware, monitors,
printers and other peripherals in an environmentally sound manner. Potential methods include
reuse of parts or whole products and recycling products, components and/or materials.
Battery disposal
Batteries should be recycled in accordance with the laws governed by your Country, State or County.
In the US, please refer to the EPA guidelines for guidelines for the disposal of hazardous waste material at http://
www.epa.gov/epawaste/hazard/index.htm.
Take batteries to your local Hazardous Waste Collection Facility for disposal. To find the nearest recycling facility in
the US, go to http//earth911.com and enter your postal ZIP code.
• DO NOT EXPOSE TO FIRE OR HIGH TEMPERATURES (140 °F/60 °C)
• DO NOT DISASSEMBLE• DO NOT SHORT THE TERMINALS
W E E E D i re c t i ve
The following is the test of the Waste Electrical and Electronic Equipment (WEEE) Directive.
In the European Union, this label indicates that this product should not be disposed of with household
waste. It should be deposited at an appropriate facility to enable recovery and recycling.
The Crossmatch WEEE Registration number is 60744969.
Verifier® Sentry Operator Manual 870391 V1.0
Description
T HIS CHAPTER DESCRIBES THE V ERIFIER ® S ENTRY AND THE FEATURES THAT YOU CAN USE TO CAPTURE THE
BIOMETRIC INFORMATION .
The Verifier® Sentry is a portable identification and verification device that provides many methods to capture
personal and biometric information. Strong design, small size and light weight makes the device easy to use in the
field. The device can scan CAC/PIV, Contact and Contactless smart cards. The Verifier® Sentry can read the Machine
Readable Zone (MRZ) on an ePassport and read the chip embedded in the passport.
Introduction
Description
T h e f ro n t o f t h e S e n t r y
Figure 1
The front of the Sentry
The front of the Sentry contains the features that allow the operator to monitor the state of the device. The following
table describes the features.
Table 6
The front of the Sentry
Description
The finger is pressed on the platen surface to capture the fingerprint.
The speaker.
The Capacitive Touch Screen is sensitive to contact by a finger or a capacitive stylus.
When the battery accepts a charge, the Charge indicator illuminates.
• A Red light indicates 500 mA of electricity is supplied to the Sentry. This current the amount required to
operate the Sentry, but less than the amount required to charge the Sentry.
• An Amber light indicates 1500 mA of electricity is supplied to the Sentry.
• A Green light indicates the Sentry is supplied the correct amount of electricity by the Docking Station.
This arrangement allows the device to operate and accept the fastest rate of charge.
The microphone.
The Status indicator. The Android hardware API controls this LED.
Verifier® Sentry Operator Manual 870391 V1.0
Description
The left side of the Sentry
Figure 2
The left side of the Sentry
The following table describes the left side of the Sentry.
Table 7
The left side of the Sentry
Description
®
The top-end of the Verifier Sentry.
The mounting points for accessories.
During normal operation, this port allows the Sentry to be a memory or camera device to a host
computer.
When the On The Go (OTG) adapter is used, the USB connector allows the Sentry to be a host
computer for an external USB device.
The connector can be a charge point.
When connected to a laptop, the connector is a device endpoint.
The attached cover for the USB connector is shown open.
This is the data connection for an accessory.
Introduction
Description
The right side of the Sentry
Figure 3
The right side of the Sentry
The following table describes the features on the right side of the Sentry.
Table 8
The right side of the Sentry
Description
®
The top-end of the Verifier Sentry.
The button to increase the output from the speaker or from the earphones.
The button to decrease the output from the speaker or from the earphones.
The Start button.
The connection point for earphones and a microphone. The jack is one eighth of an inch in
diameter.
The slot for a contact card. An application is required to display the data on the screen. When the
operator inserts the card, the gold contacts on the top surface of card must be visible. See “Scan a
Contact Card” on page 13.
Verifier® Sentry Operator Manual 870391 V1.0
Description
The back of the Sentry
The back of the Verifier® Sentry
Figure 4
The following table describes the features on the back of the Sentry.
Table 9
The back of the Sentry
Description
The camera and camera lens.
The light source for the bar code scanner.
The release latch for the battery cover.
The cover for the battery compartment.
Contactless card Reader area. The card can be outside the hand strap. See “Scan a
Contactless Card” on page 14.
The attachment bars for the hand strap.
Alignment slots for the docking station.
The photo light source provides illumination for photos captured with the camera. The light is
disabled until the camera is enabled.
Introduction
Description
The top of the Sentry
Figure 5
The top of the Verifier® Sentry
The following table explains the features on the top of the Verifier® Sentry.
Table 10
The top of the Verifier® Sentry
Description
The bezel around the platen.
The slot allows a tool provided by Crossmatch to release the sensor from the Verifier® Sentry. See
“Replace the fingerprint sensor” on page 24.
The top attachment bar for the hand strap. The hand strap is not shown.
The bottom of the Sentry
Figure 6
The bottom of the Verifier® Sentry
The following table describes the features of the bottom of the device.
Table 11
The bottom of the Verifier® Sentry
Description
10
The connection point for the optional docking station.
Two slots that fit over two tabs on the optional docking station to correctly align the Verifier® Sentry.
The bottom attachment bar for the hand strap.
Verifier® Sentry Operator Manual 870391 V1.0
Use the Sentry
THIS CHAPTER DESCRIBES HOW TO START AND STOP THE SENTRY. THE CHAPTER ALSO DESCRIBES THE TASKS THE
OPERATOR CAN PERFORM WITH THE SENTRY.
Start the Sentry
Follow the procedure to turn on the Sentry.
1 Press and hold the Start button. The Status indicator illuminates.
2 Release the Start button. The start sequence begins. The Sentry desktop appears. The Sentry is started.
The illustration shows the Sentry desktop. The desktop is a normal Android desktop. A tutorial is available on the
Internet for the Android JB operating system.
Table 12
Items on the Sentry desktop
Description
The Apps icon. Touch this icon to see one or more screens that contain the icons for applications installed on
the Sentry.
11
Introduction
Use the Sentry
Stop the Sentry
Use the following steps to stop the Sentry.
1 Press and hold the Start button until the Mode menu appears.
2 Select Power off. The Power off menu appears.
3 Select OK to turn off the Sentry or select Cancel to return to the desktop.
The following sections describe the procedures that the operator can do with the Sentry. The illustrations in the
following procedures show a Crossmatch demonstration application. The actions for the procedures are the normal for
similar applications.
1 Start the application.
2 Sign into the application
3 The Home window appears with the Main menu for the application displayed. The main menu for other
applications can contain different selections.
12
Verifier® Sentry Operator Manual 870391 V1.0
Use the Sentry
S c a n a C o n t a c t C a rd
The following procedure shows how to scan data from a Contact card and verify the data with the Sentry. The
application in the illustration is a Crossmatch demonstration application. Your application can appear different.
1 Start the application.
2 Sign into the application The Home window appears with the Main menu for
the application displayed. The application in the illustration is a Crossmatch
demonstration application. Your application can be different.
Touch to select Contact Card. The instruction to insert the card and enter a PIN
appears.
Enter the PIN
Insert the card, with the picture visible, into the slot in the right-side of the
Sentry. See “The right side of the Sentry” on page 8.
Enter the PIN.
Touch the Submit button.
8 The Sentry scans the card and the application displays the data from the card on
the screen. The workflow in the example application requires the operator to
verify the fingerprint.
13
Introduction
Use the Sentry
9 Touch the Verify Fingerprint button. The Fingerprint Capture window appears
10 Tell the person to press the correct finger on the platen of the Sentry. The
fingerprint appears in the window. The Sentry captures the fingerprint. The
application compares the fingerprint to the fingerprint stored on the card.
If the fingerprint matches, a green line appears above and below the fingerprint
and a message appears in the window.
If the fingerprint does not match, a red line above and below the fingerprint and
a message appears in the window.
11 Take the action required by the procedures for the organization.
S c a n a C o n t a c t l e s s C a rd
The following procedure shows how to scan the data from a Contactless card and
verify the data with the Sentry. The application in the illustration is a Crossmatch
demonstration application. Your application can appear different.
1 Touch to select Contactless Card. The instruction to scan the card appears.
2 Put the card near the Contactless Card Reader area on the back of the Sentry. See
“The back of the Sentry” on page 9.
14
Verifier® Sentry Operator Manual 870391 V1.0
Use the Sentry
3 The Sentry scans the card and the application displays the data from the card on
the screen. If the scanner does not read the card, a message appears. The
workflow requires the operator to verify the fingerprint.
4 Touch the Verify Fingerprint button. The Fingerprint Capture window appears
5 Tell the person to press the correct finger on the platen of the Sentry. The
fingerprint appears in the window. The Sentry captures the fingerprint and the
application compares the fingerprint to the fingerprint stored on the card.
If the fingerprint matches, a green line appears above and below the fingerprint
and a message appears in the window.
If the fingerprint does not match, a red line above and below the fingerprint and
a message appears in the window.
6 Take the action required by the procedures for the organization.
15
Introduction
Use the Sentry
R e a d a n e Pa s s p o r t
The following procedure shows how to scan the data from an ePassport with the Sentry.
Note
Some ePassports can contain levels of data encryption that the application cannot read.
1 Touch ePassport from the main menu. The ePassport Scan window appears. The
application in the illustration is a Crossmatch demonstration application. Your
application can appear different.
2 Touch Scan Passport MRZ. The Sentry camera turns on and displays a white
box.
3 Adjust the image of the MRZ area to appear inside the white box. The Sentry
scans the MRZ and displays the information in a screen
4 Touch Accept to keep the information, or touch Re-scan to scan the MRZ area again.
5 The Date of Birth, the Expiration Date and the Passport Number appear in the ePassport Scan screen.
Note
The operator can enter the required information in the ePassport information boxes. When the operator touches an
information box, the keyboard appears for data entry.
16
Verifier® Sentry Operator Manual 870391 V1.0
Use the Sentry
6 Put the page of the passport that contains the chip near the Contactless Card
Reader on the back of the Sentry. See “The back of the Sentry” on page 9. The
Sentry reads the chip and the application displays the data from the chip on the
screen.
Note
When the application does not read the encrypted data on the chip, a message appears
on the screen.
7 To complete the ePassport process, the operator takes the actions described in the
procedures for the organization.
C a p t u re a n d ve r i f y t h e b i o m e t r i c s
An application is required to capture and save the biometrics for comparison to database records. The following steps
describe how to capture a fingerprint with a Crossmatch demonstration program. Your application can appear
different. The required steps are the same.
1 Start the application to capture the biometrics.
2 Sign into the application. The Home window appears.
3 Select Search to begin the fingerprint capture process.
17
Introduction
Use the Sentry
4 Follow the instructions on the screen to capture the fingerprints.
Follow the procedure to capture a face photo of the person.
The demonstration application puts a box on the screen.
Put the face of the person into the box. The application captures the photo.
Touch the Use button. The application compares the biometrics to a database and reports the results of the
comparison.
9 To complete the process, the operator takes the actions described in the procedures for the organization.
C a p t u re a p h o t o g ra p h
An application is required to capture a photograph and save the photograph in a record.
Start the Sentry.
Start the application to save the photograph.
Sign into the application.
Select the camera from the desktop.
Take the photograph.
Follow the instructions to save the photograph in the record.
R e a d a b a rc o d e
An application is required to read a barcode and save the data in a record. The application shown here is a Crossmatch
demonstration application.
1 Start the Sentry.
2 Start the application to scan the barcode. The camera starts and displays red cross hairs over the image.
3 If more light is required, touch the button that turns on the light.
18
Verifier® Sentry Operator Manual 870391 V1.0
Use the Sentry
4 Adjust the Sentry to center the cross hairs in the barcode.
The cross hairs turn green and green brackets appear to frame the barcode image. The application captures the data in
the barcode. The barcode information appears on the Sentry screen.
5 Follow the work flow instructions to save the barcode information.
19
Introduction
Use the Sentry
20
Verifier® Sentry Operator Manual 870391 V1.0
Maintenance
THIS DOCUMENT DESCRIBES THE MAINTENANCE THAT THE OPERATOR CAN PERFORM ON THE SENTRY.
Figure 7
The Sentry battery compartment (battery removed)
Table 13
Items in the Sentry battery compartment
The cover latch for the battery compartment. The latch slides to release the cover. The latch automatically returns to
the closed position.
The socket for the SIM card accepts a normal size SIM card (recommended). An adapter tray is required for smaller
SIM cards.
The latch that indicates that the battery is installed. The battery compresses the latch and the installation is
recorded in the log. When the battery is removed, the latch is released and the removal of the battery is recorded.
The socket for a SAM card. There are two sockets.
The product label for the Sentry.
The Micro SD card socket.
The battery connection points for the Sentry.
R e m ov e t h e b a t t e r y
Use the following procedure to remove the battery.
Press and hold the Start switch to turn off the Sentry.
Hold the Sentry with the back of the device visible.
Loosen the hand strap.
Slide and hold the latch for the cover in the open position.
Apply enough pressure to slide the cover away from the latch until it stops.
Release the latch and lift the cover from the Sentry.
Lift the bottom of the battery and remove the battery from the battery compartment.
21
Introduction
Maintenance
Install the battery
Remove the old battery, if necessary. See “Remove the battery” on page 21.
Hold the battery with the label visible.
Put the connection points on the battery against the connection points (7) in the battery compartment.
Press to install the battery.
Put the cover in position over the battery compartment.
Note
If the cover does not fit correctly over the battery compartment, check the position of the seal assembly inside the cover.
The assembly must extend under the hook for the cover latch. If necessary, slide the assembly toward the hook. When in
the correct position, the assembly stops.
6 Apply enough pressure to slide the cover toward the latch. When the cover closes, you hear the cover latch reset.
7 Tighten the hand strap.
I n s e r t a S A M c a rd
Use the following procedure to insert a SAM card. There are two SAM card connectors in the battery compartment,
next to the Sentry label.
1 Remove the battery. See “Remove the battery” on page 21.
2 Select an empty SAM connector.
3 Use a fingernail to unlock and move the SAM cover toward the center of the
Sentry.
4 Open the SAM cover until the cover stops.
5 Insert the SAM card into the cover. The card inserts with the chamfer on the card
as shown in the illustration.
6 Close and lock the SAM cover.
7 Insert the battery. See “Install the battery” on page 22.
R e m ov e a S A M c a rd
Use the following procedure to remove a SAM card. There are two SAM card connectors in the battery compartment,
next to the Sentry label.
1 Remove the battery. See “Remove the battery” on page 21.
2 Select SAM card to remove.
3 Use a fingernail to unlock and slide the SAM cover toward the center of the
22
Sentry.
Open the SAM cover until the cover stops.
Slide the SAM card out of the cover.
Close and lock the SAM cover.
Insert the battery. See “Install the battery” on page 22.
Verifier® Sentry Operator Manual 870391 V1.0
Maintenance
I n s e r t t h e S I M c a rd
Use the following procedure to insert a SIM card into the Sentry. The SIM card connector is in the side of the battery
compartment next to the battery contacts.
1 Remove the battery. See “Remove the battery” on page 21.
2 Insert the SIM card into the SIM slot and press until the card stays in the slot.
3 Insert the battery. “Install the battery” on page 22.
R e m ov e t h e S I M c a rd
Use the following procedure to remove a SIM card from the Sentry. The SIM card connector is in the side of the
battery compartment next to the battery contacts.
Remove the battery. See “Remove the battery” on page 21.
Press the SIM card into the SIM slot until the card releases from the slot.
Remove the SIM card.
Insert the battery. See “Install the battery” on page 22.
I n s e r t t h e M i c ro S D c a rd
Use the following procedure to insert the Micro SD card into the Sentry. The Micro SD card connector is in the floor of
the battery compartment, next to the battery contacts.
1 Remove the battery. See “Remove the battery” on page 21.
2 Use a fingertip to slide the Micro SD cover toward the Sentry label and unlock
the cover.
Open the cover.
Insert the Micro SD card into the cover.
Close the cover on the Micro SD card connector.
Insert the battery. See “Install the battery” on page 22.
23
Introduction
Maintenance
R e m ov e t h e M i c ro S D c a rd
Use the following procedure to remove the Micro SD card from the Sentry. The Micro SD card connector is in the floor
of the battery compartment, next to the battery contacts.
1 Remove the battery. See “Remove the battery” on page 21.
2 Use a fingertip to slide the Micro SD cover toward the Sentry label and unlock
the cover.
Open the cover.
Remove the Micro SD card.
Close and lock the cover on the Micro SD card connector.
Insert the battery. See “Install the battery” on page 22.
F i n d t h e P ro d u c t L a b e l
Use the following procedure to find the product label for the Sentry.
1 Remove the battery. See “Remove the battery” on page 21.
2 The product label is visible in the battery compartment near the two SAM card connectors.
3 Insert the battery. See “Install the battery” on page 22.
Replace the fingerprint sensor
If the fingerprint sensor must be changed, Crossmatch provides a Sensor Replacement kit. The part number of the kit is
8880125-001. The kit includes a sensor, a special tool and complete instructions to replace the sensor.
24
Verifier® Sentry Operator Manual 870391 V1.0
Customer Care
THIS CHAPTER DESCRIBES THE TECHNICAL ASSISTANCE AVAILABLE FOR THE SENTRY AND PROVIDES CONTACT INFORMATION.
Tec h n i c a l S u p p o r t
Technical support from the Customer Care department is available for the Sentry.
E-mail
Crossmatch Customer Care provides free technical support on-line during the warranty period, in the order that the
requests are received.
Global
CustomerCare@crossmatch.comGlobal
If the warranty has expired, use the telephone or facsimile to contact the Customer Care department.
Tel e p h o n e a n d f a c s i m i l e
The Customer Care is available at the following telephone numbers:
Global
Monday- Friday 8 am to 6 pm EST
Customer Care
Tel: 1.866.276.7761 (Toll Free)
Tel: 1.561.622.9210 (International)
Fax: 1.561.622.8769
Technical support is available for the Sentry during the warranty period at zero charge (see “Warranty” for Warranty
Terms). After the warranty has expired, technical support is available at a given cost per hour. Contact the Customer
Care department.
The Customer Care for the software products and the services purchased from Crossmatch is not included in the
warranty. The Customer Care for other products is available at a given cost to the customer.
When you contact the Customer Care department, make sure that you can provide the following information:
• Company name
• Contact person
• The Sentry serial number
• The error messages that appear on the screen
25
Introduction
Customer Care
R e t u r n a n d re p a i r o f t h e S e n t r y
You must receive an RMA number to return the Sentry for repair or replacement. Contact the Customer Care
department to request and receive an RMA number. Put the RMA number on the outside of the box and on the label.
North and South America
Crossmatch
3960 RCA Boulevard, Suite 6001
Palm Beach Gardens, Florida
33410
USA
RMA: Rnnnn.nnnn
The product is sent to the correct department for service or replacement, then returned to the customer. Any product
sent to Crossmatch without an RMA number is returned.
D e l i ve r y c o s t s
The product is in the warranty period
• The customer accepts all charges to send the product to Crossmatch for service.
• Crossmatch accepts all charges to return the product to the customer.
The product is not in the warranty period
• The customer accepts all charges.
Note
You must return a product in the original boxes. If the original boxes are not available,
contact the Customer Care department for instructions.
Contact information
Corporate Headquarters
Crossmatch
3950 RCA Boulevard, Suite 5001
Palm Beach Gardens, FL 33410
USA
T: +1 (561) 622-1650
F: +1 (561) 622-9938
T: (866) 725-3926 (Toll Free)
General Mailbox: info@crossmatch.com
Sales Department: sales@crossmatch.com
Customer Care: CustomerCare@crossmatch.com
Corporate Web Page: www.crossmatch.com
26
Verifier® Sentry Operator Manual 870391 V1.0
Warranty
THIS CHAPTER CONTAINS THE CROSSMATCH WARRANTY FOR THE SENTRY.
L I M I T E D WAR R A N T Y
Cross Match Technologies, Inc. (“Crossmatch”) warrants that the Crossmatch Equipment you have purchased will be
free from defects in material and workmanship in normal service and under normal conditions for a period of one year
from the date of shipment. Normal service and normal conditions are defined in the documentation. This Limited
Warranty is subject to the terms and conditions set forth below.
Repair or replacement: Unless otherwise stated herein, the sole obligation of Crossmatch and your exclusive remedy
and recourse under this Limited Warranty is for Crossmatch, at its sole election, to either (i) repair the suspected
defective Equipment and return the same to you or (ii) replace the suspected defective Equipment, all on the terms set
forth below. The repair or replacement will provide you with Equipment, which in Crossmatch’s opinion, performs
consistently with its age and usage.
If you become aware that your Crossmatch Equipment is defective in material or workmanship in normal service and
under normal conditions during its one year Limited Warranty period, then you must promptly contact Crossmatch’s
Customer Care Center between Monday through Friday, 8:00am to 6:00pm EST, excluding Crossmatch holidays,
describe the suspected defect in detail and request a Return Merchandise Authorization (“RMA”) number prior to
sending the affected Equipment for repair or requesting a replacement. Please see your equipment manual for more
information on RMA’s. You will pay the freight to send the Equipment to Crossmatch’s designated Service Center,
and Crossmatch will pay the freight to return the repaired Equipment to you. Each repaired or replacement Equipment
is warranted (as set forth herein) for the remaining portion of the original one-year Limited Warranty.
THE FOREGOING CONSTITUTES YOUR SOLE AND EXCLUSIVE REMEDY AND CROSSMATCH’S SOLE
AND EXCLUSIVE LIABILITY IN CONNECTION WITH YOUR CROSSMATCH EQUIPMENT, AND IS IN
LIEU OF ANY AND ALL OTHER REMEDIES WHICH MAY BE AVAILABLE TO YOU.
Limitations: This limited warranty does not cover visits to repair the Crossmatch Equipment at your premises, or the
commissioning of the Equipment on site. This Limited Warranty is not a warranty, guarantee or promise that your
Crossmatch Equipment will conform to its specification or will not fail.
Crossmatch shall incur no liability under this Limited Warranty and this Limited Warranty is voidable by Crossmatch
if in Crossmatch’s sole reasonable opinion: (a) the Equipment is used other than under normal use and under proper
environmental and/or electrical conditions, as specified in the manual; (b) the Equipment is not maintained as specified
in the equipment manual; (c) the Equipment is subject to abuse, misuse, neglect, accident, flooding, storm, lightning,
power surges, dirty power, third-party errors or omissions, or acts of God; (d) the Equipment is modified or altered
(unless expressly authorized in writing by Crossmatch); (e) the Equipment is installed or used in combination or in
assembly with equipment or other products not supplied or authorized by Crossmatch; (f) there is a failure to follow
specific restrictions or operating instructions; (g) database recovery, (h) Crossmatch on-site support, (i) remedial
customer training; (j) user or virus caused software reloads; (k) data migration to new platform; or (l) payment for the
Equipment has not been timely made.
The Limited Warranty does not cover nondurable consumable items including, but not limited to, batteries, paper,
silicon pads, cleaning solution, towels, printer cartridges and cables. Replacement supplies of these items may be
ordered by contacting Crossmatch Sales at 866-725-3926 (toll free in the US) or 561-622-9722. This Limited
Warranty does not cover third party peripheral equipment (such as laptops and printers) that is not connected or
otherwise used in conjunction with the Crossmatch Equipment. Customers should contact the manufacturer of such
third party equipment regarding suspected defects in such equipment.
Crossmatch’s obligations hereunder are contingent upon your providing the Equipment serial number as proof-ofpurchase, and upon Crossmatch’s determination that the suspected malfunction is actually due to defects in material or
workmanship.
THIS LIMITED WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES RELATED TO THE
CROSSMATCH EQUIPMENT, WHETHER EXPRESS, IMPLIED, OR STATUTORY, INCLUDING THE
WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, ALL OF
WHICH ARE HEREBY EXPRESSLY DISCLAIMED BY CROSSMATCH. THIS LIMITED WARRANTY
IS NOT TRANSFERABLE OR ASSIGNABLE TO ANY THIRD PARTY AND SHALL BE FOR THE SOLE
AND EXCLUSIVE BENEFIT OF THE ORIGINAL OEM OF THE CROSSMATCH EQUIPMENT
27
Introduction
Warranty
COVERED HEREUNDER; ANY ATTEMPTED TRANSFER OR ASSIGNMENT HEREOF SHALL BE
VOID AB INITIO.
Crossmatch reserves the right to improve/modify equipment at any time, at its sole discretion, as it deems necessary.
Out of warranty repairs: When warranty coverage for your Crossmatch Equipment lapses, or for repairs or
replacements not covered by Crossmatch’s warranty, (i) you will pay for all repairs at Crossmatch’s then-prevailing
hourly labor rate (with a one hour minimum) plus parts and shipping, (ii) you will pay Crossmatch’s then-current price
for all replacement Equipment plus shipping, and (iii) you will pay Crossmatch’s then-prevailing hourly labor rate
(with a one hour minimum after the first 15 minutes) for telephone support in 15 minute increments.
To obtain out-of-warranty service, you must obtain an RMA number and send the affected Equipment, at your expense,
to the designated Crossmatch Service Center for inspection. You will be contacted with an estimated price and time of
repair or replacement after analysis. No repairs or replacements will be made until Crossmatch receives a Purchase
Order or credit card number from you. You shall pay return freight charges, which will be added to the invoice, for the
return of the repaired or replaced Equipment.
In the event you decide not to have a unit repaired or replaced after receiving a repair estimate, there will be a one hour
labor charge at the prevailing hourly rate for evaluation plus return freight charges.
At your request, Crossmatch will, for a premium, ship a refurbished unit to you in exchange for the failed unit.
Crossmatch will contact you with a price for the exchange after receipt of the failed unit. The shipment will be made
when Crossmatch receives a Purchase Order or credit card number from you. You will pay return freight charges,
which will be added to the invoice, for the exchange unit. The original returned Equipment will become the property
of Crossmatch and will not be returned to you. The refurbished unit will retain the remaining warranty term of the
original returned Equipment.
28
Verifier® Sentry Operator Manual 870391 V1.0
Index
accessories for the Sentry 3
alignment slots for the docking station 9 , 10
applications 3
attachment bars for the hand strap 9
Auto Capture™ 2
glossary 2
Auto Capture™ 2
bluetooth 2
flat fingerprint 2
GPS 2
USB 2.0 2
user 2
Wi-Fi 2
back of the Sentry 9
battery compartment cover 9
battery cover release latch 9
battery disposal 4
bezel cover release 10
biometric / credential capture 2
bluetooth 2
bottom attachment for the hand strap 10
bottom of the Sentry 10
button to decrease the volume 8
camera and camera lens 9
capture a photograph 17 , 18
capture and verify the biometrics 17
change the battery 21
charge light 6
charge point 7
company
sales number 26
contact card slot 8
contact information 26
corporate headquarters 26
contactless card reader 9
corporate headquarters 26
corporate web page 26
Crossmatch WEEE registration number 4
data connection for an accessory 7
delivery costs 26
desktop for the Sentry 11
device endpoint 7
docking station alignment slots 9
docking station connection 10
e-mail 25
e-mail, see contact information
FCC RF exposure requirements 3
FCC statement 3
flat fingerprints 2
flats 2
freight guidelines 26
not under warranty 26
under warranty 26
front of the Sentry 6
hand strap attachment 10
help 25
technical 25
how this book is arranged 1
how to use the Sentry 11 , 21 , 25 , 27
Industry Canada statement 3
insert a micro sd card 23
insert a sam card 22
insert a simm card 23
insert the Micro SD card 23
insert the SIM card 23
install the battery 22
left side of the Sentry 7
licenses
the Cellular License information for Gemalto M2M
GmbH 4
Wi-Fi/Bluetooth License from LS Research 4
light source for the bar code reader 9
microphone 6
not under warranty 26
photo light source 9
platen 2
platen bezel 10
platen surface 6
product in warranty period 26
product label for the Sentry 24
product not in warranty period 26
read a barcode 18
read a contact card 18
read an epassport 16
recycling information 4
remove a SAM card 22
remove the battery 21
remove the Micro SD card 24
remove the SIM card 23
Index-1
Index
return and repair of the Avenger 26
returns and repair 26
right side of the Sentry 8
right side of the sentry 8
rma number 26
scan a contact card 13
scan a contactless card 14
Sentry
accessories 3
attachment for the hand strap 10
back 9
battery compartment cover 9
bezel around the platen 10
bottom 10
bottom attachment for the hand strap 10
button to decrease the volume 8
button to increase the volume 8
camera and camera lens 9
capture a photograph 18
capture and verify the biometrics 17
charge light 6
charge point 7
connection point for the optional docking station 10
cover for the battery compartment 9
data connection for an accessory 7
desktop 11
docking station alignment slots 10
front 6
left side 7
light source for photos 9
light source for the bar code reader 9
microphone 6
platen surface 6
read a barcode 18
reader for a contactless card 9
release for the bezel cover 10
release latch for the battery cover 9
right side 8
scan a contact card 13
scan a contactless card 14
slot for a contact card 8
speaker 6
Index-2
start 11
start button 8
tasks 25
top 10
touch screen 6
USB connector 7
USB connector cover 7
speaker 6
specifications 2
standards 1
start button 8
start the Sentry 11
supplies 26
tasks with the Sentry 25
technical help 25
technical support 25
e-mail
returns and repair 26
telephone and fax 25
telephone and facsimile 25
terms
platen 2
top of the Sentry 10
touch screen 6
under warranty 26
USB 2.0 2
USB connector 7
USB connector cover 7
user 2
volume buttons 8
web page 26
WEEE directive 4
WEEE registration number 4
WiFi 2
Verifier® Sentry Operator Manual 870391 V1.0

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : Yes
Author                          : linda.garneau
Create Date                     : 2015:04:06 15:58:27Z
Modify Date                     : 2015:04:06 16:27:42-04:00
Language                        : en
XMP Toolkit                     : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04
Format                          : application/pdf
Creator                         : linda.garneau
Title                           : Sentry (A4).book
Creator Tool                    : FrameMaker 12.0
Metadata Date                   : 2015:04:06 16:27:42-04:00
Producer                        : Acrobat Distiller 10.1.13 (Windows)
Document ID                     : uuid:9363d76a-e027-4c1b-98b0-99b22aaaa9bc
Instance ID                     : uuid:02e35649-a24d-49f4-bf4b-ed1a8e93f2ad
Page Mode                       : UseOutlines
Page Count                      : 38
EXIF Metadata provided by EXIF.tools
FCC ID Filing: Q9YSENTRY1

Navigation menu