Crouzet Hsv User Manual
Hsv HSV HSV datasheet library assets cdn.crouzet-control.com
2017-07-05
User Manual: Crouzet Hsv HSV en datasheet library assets
Open the PDF directly: View PDF .
Page Count: 5
Download | |
Open PDF In Browser | View PDF |
››HSV ››Monitoring Relays ››Speed Monitoring Relays ››DIN Rail Mount 35 mm ››Control of overspeed, underspeed, operating rate, stopping ››Measurement via discrete sensors - 3-wire PNP or NPN, Namur, voltage 0-30V or volt-free contact type ››Works with either NO or NC sensors ››Time between pulses adjustable from 0.05 s to 10 min. ››Power-on inhibit time, adjustable from 0.6 to 60 s ››Inhibit time can be managed via an external contact Specifications Nominal voltage (V) Code 24 →240 V AC/DC 84874320 Power supply Supply voltage Un 24 V →240 V AC/DC Voltage supply tolerance -15 % / +10 % Operating range 20,4 V →264 V AC/DC Polarity with DC voltage No AC supply voltage frequency 50 / 60 Hz ±10 % Galvanic isolation of power supply/measurement No Power consumption at Un 5 VA in AC/3 W in DC Immunity from micro power cuts 50 ms Inputs and measuring circuit Input circuit 3-wire sensors PNP or NPN, 12V, 50 mA max. Input circuit NAMUR sensor 12 V / 1.5 KOhm(s) * Input circuit Contact 12 V / 9.5 KOhm(s) 0 V min. /30 V max. /9.5 KOhm(s) Input circuit Voltage input High state 4.5 V min. Low state 1 V max. Minimum pulse time 5 ms in high and low state Frequency of measured signal 1.5 m Hz minimum, 22 Hz maximum Measurement ranges 0,5 s - 1 s - 5 s - 10 s - 1 mn - 5 mn - 10 mn Threshold adjustment 10 →100 % of the range Fixed hysteresis 5 % of displayed threshold Display precision ±10 % of full scale Repetition accuracy with constant parameters ± 0,5 % Measuring error with voltage drift < 1 % across the whole range Measuring error with temperature drift ± 0,1 % / °C max. I Monitoring Relays I 02 I www.crouzet-control.com Time delays Maximum threshold crossing response time 15 ms Reset time S2 50 ms minimum (in memory mode) Reset time In memory mode (power break) : 1500 ms minimum Inhibit time delay On energisation : 0,6 →60 s (0, +10 % of full scale) Repetition accuracy with constant parameters ± 0,5 % Delay on pick-up 50 ms Display precision ±10 % of full scale Outputs Type of output 1 single pole changeover relay Type of contacts No cadmium Maximum breaking voltage 250 V AC/ DC Max. breaking current 5A AC/DC Min. breaking current 10 mA / 5 V DC Electrical life (number of operations) 1 x 10⁵ Breaking capacity (resistive) 1250 VA AC Maximum rate 360 operations/hour at full load Operating categories acc. to IEC/EN 60947-5-1 AC 12, AC 13, AC 14, AC 15, DC 12, DC 13, DC 14 Mechanical life (operations) 30 x 10⁶ Insulation Nominal insulation voltage IEC/EN 60664-1 250 V Insulation coordination (IEC/EN 60664-1) Overvoltage category III : degree of pollution 3 Rated impulse withstand voltage (IEC/EN 60664-1) 4 KV (1,2 / 50 μs) Dielectric strength (IEC/EN 60664-1) 2 kV AC 50 Hz 1 min Insulation resistance (IEC/EN 60664-1) > 500 MOhm(s) / 500 V DC General characteristics Display power supply Green LED Display relay Yellow LED Inhibit display Yellow LED Casing 35 mm Mounting On 35 mm symmetrical DIN rail, IEC/EN 60715 Mounting position All positions Material : enclosure plastic type VO to UL94 standard Incandescent wire test according to IEC 60695-2-11 & NF EN 60695-2-11 Protection (IEC/EN 60529) Terminal block : IP20 Weight 120 g Connecting capacity IEC/EN 60947-1 Rigid : 1 x 4² - 2 x 2.5² mm² Casing : IP30 1 x 11 AWG - 2 x 14 AWG Flexible with ferrules : 1 x 2.5² - 2 x 1.5² mm² 1 x 14 AWG - 2 x 16 AWG Max. tightening torques IEC/EN 60947-1 0,6 →1 Nm / 5,3 →8,8 Lbf.In Operating temperature IEC/EN 60068-2 -20 →+50 °C Storage temperature IEC/EN 60068-2 -40 →+70 °C Humidity IEC/EN 60068-2-30 2 x 24 hr cycle 95 % RH max. without condensation 55 °C Vibrations according to IEC/EN60068-2-6 10 →150 Hz, A = 0.035 mm Shocks IEC/EN 60068-2-6 5g Standards Marking CE (DBT) 2006/95/EC - EMC 2004/108/EC Product standard NF EN 60255-6 / IECI 60255-6 / UL 508 / CSA C22.2 N°14 I Monitoring Relays I 03 I www.crouzet-control.com Standards Electromagnetic compatibility (EMC) Immunity EN 61000-6-2/IEC 61000-6-2 Emission EN 61000-6-4/EN 61000-6-3 IEC 61000-6-4/IEC 61000-6-3 Emission EN 55022 class B Certifications UL, CSA Conformity with environmental directives RoHS Comments The IEC 60947-5-6/1999-12 NAMUR standard does not impose the operating voltage (open circuit voltage) or the load resistance (source resistance of the control amplifier), but it defines the test conditions for which, using the sensor voltage/current characteristics with high and low impedance, the normal operating zones are specified. The great majority of NAMUR sensors use a 12 V supply voltage. Matching the load resistance to the operating voltage allows the nominal switching distance to be maintained. Dimensions HSV 60 44 23,2 35 90 2,6 45 67,5 3,5 5,5 Curves Connections HSV - Input circuits 2 1 E2 0V 11 Y1 12 V 12 V E1 +/– 24…240 V 50/60 Hz –/+ A2 14 A1 S1 12 R 12 11 14 I Monitoring Relays I 04 I www.crouzet-control.com Connections 2 + – 1 Y1 12 V 12 V E1 0V 11 E2 A2 14 A1 12 R 12 11 14 S1 +/– 24…240 V 50/60 Hz –/+ 2 B BU BK 1 E2 0V 11 Y1 12 V 12 V E1 +/– A2 14 A1 12 R 12 11 14 S1 24…240 V 50/60 Hz –/+ 2 + ℮ – E2 0V 1 11 Y1 12 V 12 V E1 +/– 24…240 V 50/60 Hz –/+ A2 14 A1 S1 12 R 12 11 14 I Monitoring Relays Connections I 05 I www.crouzet-control.com