Culligan Hd 202 Users Manual Hi Flo 55 Filters
HD-242 Hi-Flo55
2015-02-05
: Culligan Culligan-Hd-202-Users-Manual-533599 culligan-hd-202-users-manual-533599 culligan pdf
Open the PDF directly: View PDF .
Page Count: 19
Download | |
Open PDF In Browser | View PDF |
More Culligan® Heavy Duty Commercial Filters apartments assisted living facilities cafeterias casinos corporate campuses educational facilities food service government grocery health clubs hotel/ hospitality institutions laundry manufacturing facilities theme parks travel centers vehicle wash Culligan’s Hi-Flo® 55e Commercial Filters Standard Features • 24 Volt Culligan’s MVP™ Controller – Field programmable with a back-lit LCD display and UL listed 120v/24v transformer. • Single, Duplex, Triplex, or Quad Configurations • Regeneration initiation by choice of time clock, meter or differential pressure switch. • Carbon Filters – For reduction of organics (flow rates up to 39gpm), or chlorine (flow rates up to 77gpm). Trust The Water Experts® • Depth Filters – Flow rates up to 193gpm. • Top-Mounted Control Valve – Keeps plumbing connections simple and adaptable. Full flow porting with rounded orifices and wide-open cartridges promote good flow characteristics and low pressure fluctuations. • Corrosion resistant tanks – Made of low carbon steel with epoxy interior lining and finish coat painted exterior. Culligan’s Hi-Flo® 55e Commercial Filters • Light Industry Processes—Reduces particulate matter. • Pretreatment—For softeners, RO’s and DI systems. • Vehicle Wash—Turbidity reduction. Applications and Benefits • Food and Beverage–Superior taste and increased cost savings. • Drinking Water–Reduces turbidity and chlorine; improves taste and clarity. • Boilers—Turbidity reduction, minimize sludge blowdown. Options Warranty Culligan’s Hi-Flo 55e water filters are backed by a limited 1-year warranty against defects in material, workmanship and corrosion. In addition, tanks carry a limited 5-year warranty.* • Patented Progressive FlowCulligan’s MVP™ controller can monitor flow demands, bringing additional tanks on-line or off-line as flows increase or decrease. • Differential Pressure Switch • A.S.M.E. Code Tanks • Sample cocks and pressure gauges • Separate source regeneration kits • Skid mounting • Flow meter Pressure: 30–100 psig 207–690 kPa 120 VAC/24 VAC 50/60 Hz 40–120°F 4–49°C Power: Temperature: * See printed warranty for details. Culligan will provide a copy of the warranty upon request. Water Quality High** Flow Rate Pressure (GPM) Loss (PSI) Utility*** Flow Rate Pressure (GPM) Loss (PSI) Backwash Flow Rate (GPM) Valve Size (inches) Depth Filters Superior* Flow Rate Pressure (GPM) Loss (PSI) HD-202 HD-242 HD-302 HD-362 HD-423 22 32 50 71 97 2 2 4 5 3 33 48 74 107 145 3 5 7 11 6 44 63 99 142 193 5 7 12 19 9 30 45 70 100 135 2 2 2 2 3 Carbon Filters Model System Specifications HR-202 HR-242 HR-302 HR-362 HR-422 191 131 201 291 391 01 11 21 21 31 14 19 30 42 58 1 1 1 4 5 182 262 402 572 772 22 22 32 62 82 20 30 45 70 100 2 2 2 2 2 * Superior – Best quality water with lowest pressure loss. Recommended for influent suspended solid loads up to and greater than 300 ppm. High – Very good quality water with increased pressure loss. Recommended for influent suspended solid loads less than 300 ppm. Utility – Satisfactory quality water with greatest pressure loss. Shorter on line time between backwashing. Recommended for influent suspended solid loads less than 150 ppm. 1 For Sediment and organic removal use the flow rates from the superior water quality column. 2 For chlorine removal only, use the flow rates from the utility water quality column. ** *** All pressure drop figures are based on new filter media and a water temperature of 60°F. Depth filters are capable of 10 micron effluent water quality, whereas all other filter types are capable of 40 micron effluent water quality. “Hey Culligan Man!”® www.culligan.com™ 1-800-CULLIGAN ©2003 Culligan International Co. Printed in USA (12/03) MOORE PART NO. 47601 ISO 9001 Certification Products manufactured and marketed by Culligan International Company (Culligan) and its affiliates are protected by patents issued or pending in the United States and other countries. Culligan reserves the right to change the specifications referred to in this literature at any time, without prior notice. , Brunermatic, Hey Culligan Man, Culligan Man, Culligan Commercial @ Work, www.culligan.com and Culligan Service Network are trademarks of Culligan International Company or its affiliates. HI-FLO® DEPTH FILTERS FOR SEDIMENT REDUCTION SPECIFICATIONS AND OPERATING DATA Hi-Flo 55 MODEL NUMBER Hi-Flo 50 HD-202 HD-242 HD-302 HD-362 HD-423 HD-483 HD-544 HD-604 HD-726 HD-846 Peak Service Flow @ Pressure Drop gpm 30 45 75 100 150 190 240 300 440 600 @ psi @3 @4 @7 @ 10 @6 @ 10 @8 @ 10 @ 10 @ 10 L/min 114 170 284 379 568 719 908 1,140 1,670 2,270 @ 21 @ 28 @ 42 @ 69 @ 41 @ 69 @ 55 @ 69 @ 69 @ 69 15 20 35 50 70 90 110 140 200 270 @ psi @1 @1 @2 @3 @2 @3 @3 @2 @2 @2 L/min 57 76 132 189 265 340 420 530 750 1,020 @ 14 @ 21 @ 14 @ 20 @ 20 @ 14 @ 14 @ 14 400 540 @ kPa Normal Service Flow @ Pressure Drop gpm @ kPa Backwash Flow @ 6.9 @ 6.9 gpm 30 45 70 100 135 188 210 270 L/min 114 170 265 379 511 712 795 1,020 in 20 24 30 36 42 48 54 60 mm 510 610 760 910 1,070 1,220 1,370 1,520 in 48 48 48 54 54 60 60 60 1,220 1,220 1,220 1,370 1,370 1,520 1,520 1,520 1,510 2,040 Tank Size Diameter Sideshell mm 72 84 1,830 2,130 60 60 1,520 1,520 Pipe Size Inlet/Outlet in 2 2 2 2 3 3 4 4 6 6 Media Volume ft3 5 8 12 17 23 32 40 49 70 97 0.142 0.227 0.340 0.481 0.651 0.906 1.13 1.39 1.98 2.75 lb 870 1,150 1,750 2,530 3,550 7,000 8,800 10,800 18,500 25,000 kg 390 520 790 1,150 1,610 3,175 4,000 3 m Ship Weight, Approx. 4,900 8,390 11,340 NOTES: 1 Service flow rates are based on 7 gpm/ft2 (26 L/m2/min) for Normal and 15 gpm/ft2 (57 L/m2/min) for Peak Flow rates. Actual service rate can vary from 2 to 20 gpm/ft2 (8 - 76 L/m2/min) depending upon the application and the raw water. 2 Backwash flow rates are based on 12-14 gpm/ft2 (45-53 L/m2/min) using 50° F (10° C) water. A different backwash rate may be required depending upon water temperature or the type of carbon used. 3 Operational, maintenance and replacement requirements are essential for this product to perform as advertised. Service is available through independently operated Culligan dealerships. Commercial Systems ©2000 Culligan 1-800-CULLIGAN www.culligan.com Printed in USA Rev. 4/00 DCO 992587 SL-0070 Moore Part No. 46924 HI-FLO® CULLAR® AUTOMATIC FILTERS FOR DECHLORINATION AND ORGANIC ADSORPTION SPECIFICATIONS AND OPERATING DATA Hi-Flo 55 Hi-Flo 50 HR-422 HR-4825 HR-543 HR-603 HR-724 HR-844 HR-202 HR-242 HR-302 HR-362 HR-423 MODEL NUMBER Dechlorination Service Flow @ Pressure Drop gpm 20 30 50 70 100 125 160 200 280 380 @ psi @2 @2 @4 @8 @ 13 @ 16 @ 18 @ 13 @ 12 @ 16 L/min 76 114 189 265 379 473 606 757 1,060 1,440 @ 14 @ 14 @ 28 @ 55 @ 90 @ 90 @ 83 @ 110 10 15 25 35 50 65 80 100 140 200 @ psi @1 @1 @2 @3 @4 @4 @6 @4 @5 @6 L/min 38 57 95 132 189 246 303 379 530 757 @ 14 @ 21 @ 28 @ 28 @ 41 @ 28 @ 34 @ 41 @ kPa @ 110 @ 124 Organics Adsorption Service Flow @ Pressure Drop gpm @ kPa Backwash Flow @ 6.9 @ 6.9 gpm 20 30 45 70 100 136 160 210 270 400 L/min 76 114 170 265 379 515 606 795 1,020 1,510 in 20 24 30 36 42 48 54 60 72 84 mm 510 610 760 910 1,070 1,220 1,370 1,520 1,830 2,130 in 48 48 48 54 54 60 60 60 60 60 1,220 1,220 1,220 1,370 1,370 1,520 1,520 1,520 1,520 1,520 Tank Size Diameter Sideshell mm Pipe Size Inlet/Outlet in 2 2 2 2 2 2.5 3 3 4 4 Media Volume ft3 6 8 12 18 24 32 40 48 70 96 0.170 0.227 0.340 0.510 0.680 0.910 1.13 1.36 1.98 2.72 lb 530 670 1,000 1,420 2,000 5,200 6,500 8,000 12,500 17,000 kg 240 300 450 640 910 2,400 2,900 3,600 3 m Ship Weight, Approx. 5,700 7,700 NOTES: 1 Service flow rates are based on 5 gpm/ft2 (19 L/m2/min) for Organic Adsorption and 10 gpm/ft2 (38 L/m2/min) for Dechlorination. Actual flow rate may vary depending upon the application and the raw water. 2 Backwash flow rates are based on 10 gpm/ft2 (38 L/m2/min) using 50° F (10° C) water. A different backwash rate may be required depending upon water temperature or the type of carbon used. 3 Operational, maintenance and replacement requirements are essential for this product to perform as advertised. Service is available through independently operated Culligan dealerships. Commercial Systems ©2000 Culligan 1-800-CULLIGAN www.culligan.com Printed in USA Rev. 4/00 DCO 992587 SL-0071 Moore Part No. 46925 HI-FLO® CULLSORB® AUTOMATIC FILTERS FOR IRON AND MANGANESE REDUCTION SPECIFICATIONS AND OPERATING DATA Hi-Flo 55 HG-202 HG-242 HG-302 HG-362 HG-423 HG-4825 HG-5425 HG-6025 HG-723 HG-844 MODEL NUMBER Service Flow @ Pressure Drop gpm 10 15 25 35 50 65 80 100 140 190 @ psi @3 @3 @4 @4 @4 @4 @6 @4 @5 @6 L/min 38 57 97 132 190 250 300 380 530 720 @ 21 @ 21 @ 28 @ 28 @ 20 @ 28 @ 41 @ 28 @ 34 @ 41 gpm 30 45 70 100 135 160 210 240 350 480 L/min 110 170 270 380 510 610 800 910 1,330 1,820 in 20 24 30 36 42 48 54 60 72 84 mm 510 610 760 910 1,070 1,220 1,370 1,520 1,830 2,130 in 48 48 48 54 54 60 60 60 60 60 1,220 1,220 1,220 1,370 1,370 1,520 1,520 1,520 1,520 1,520 @ kPa Backwash Flow Hi-Flo 50 Tank Size Diameter Sideshell mm Pipe Size Inlet/Outlet in 2 2 2 2 3 2.5 2.5 2.5 3 4 Media Volume ft3 5 8 12 19 25 34 43 53 76 104 0.156 0.212 0.340 0.538 0.708 0.962 1.22 1.50 2.15 2.94 lb 850 1,150 1,790 2,680 3,720 7,200 9,100 11,600 17,500 27,000 kg 385 522 812 1,220 1,690 3,300 4,100 3 m Ship Weight, Approx. 5,300 7,900 12,000 NOTES: 1 Service flow rates are based on 5 gpm/ft2 (19 L/m2/min). Actual flow rate may vary depending upon the application and the raw water. 2 Backwash flow rates are based on 12-14 gpm/ft2 (45-53 L/m2/min) using 50° F (10° C) water. A different backwash rate may be required depending upon water temperature or other water conditions. 3 Operational, maintenance and replacement requirements are essential for this product to perform as advertised. Service is available through independently operated Culligan dealerships. Commercial Systems ©2000 Culligan 1-800-CULLIGAN www.culligan.com Printed in USA Rev. 4/00 DCO 992587 SL-0071 Moore Part No. 46925 More Softeners Introducing the Culligan® MVP Electronic Controller • Hi-Flo ® 2E • CSM • Hi-Flo ® 55E • Hi-Flo ® 50 Filters • Hi-Flo ® 2E • Hi-Flo ® 42 • CSM • Hi-Flo ® 55E • Hi-Flo ® 50 Trust The Water Experts® M V P Multifunctional Sequences the regeneration process of water softeners or filtration systems Time, Volume, Aqua-Sensor®*or external device Can be used as a simple timer or more complex system integrator Versatile Patented Progressive Flow** feature permits smaller systems to provide greater flow rates and treatment capacities Will adapt to many types of water softeners, filters or dealkalizers As many as 6 controls may be linked together, allowing for simple, future expansion Operates on 24 VAC Programmable Time based regeneration schedule can be interval of days or hours or specific day of week Programmable trip point allows multiple units to be brought online or offline as flow demand increases or decreases Two auxilliary outputs and one input can be programmed to be active or deactive at any point of the regeneration process. Culligan® MVP Designed With The Ease of 24-volt Operation. Time of Day Displays time in 12 hour (AM/PM) or 24 hour formats. corporate campuses educational facilities Screen Blanking Allows the screen to go blank once programming is complete (After 5 minutes of no keypad activity). EEPROM Saves programmed and statistical functions. Power Source Electrical power required for the control is 24-volt 50/60 Hz AC current. A plug-in transformer (120v/24v) is provided. food service grocery hotel/hospitality One-Touch Program Update Update multiple controls through the touch of a button on the primary control. laundry vehicle wash Program Beeper Emits an audible beep when key pads are depressed to help identify valid (short beep) or invalid (3 short beeps) key pad touches. Can be enabled or disabled as desired. Lock/Unlock Allows the control to be easily locked out from inadvertent program changes or abuse. Multi-Unit Communication Input/Output (RS485) The communication input/output feature routinely recognizes when another controller within a multiple controller system is in a regeneration sequence, prohibiting the chance of multiple units regenerating simultaneously. Additional MVP Features • Battery Backup - The optional battery backup will maintain the time of day for a minimum of 4 weeks using a 3.6V 1/2AA-lithium type battery as supplied by Culligan. • Auxillary Input - capable of accepting a remote signal from a dry contact device such as an operator push-button for the purpose of initiating the regeneration sequence. • Regeneration Start Delay - A user determined number of hours (up to 9) can be input for the purpose of increasing time between multiple regeneration initiations. • Segmented Brine Draw/Rinse Cycle - Brine Reclaim Capability - allows the user to configure the system for brine reclaim with a minimum of additional valves and/or other types of hardware. ® “Hey Culligan Man!” * Aqua-Sensor: Patent # US 5,699,272 ** Progressive Flow: Patent # US 5,060,167 , # US 5,351,199 www.culligan.com 1-800-CULLIGAN ©2003 Culligan International Co. Printed in USA (5/03) MOORE PART NO. 46968 MVP Controller ISO 9001 Certification Check for compliance with state and local laws and regulations. Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system. Systems certified for cyst reduction may be used on disinfected waters that may contain filterable cysts. , Aqua-Sensor, www.culligan.com and Hey Culligan Man are trademarks of Culligan International Company. More TM THE XLF FLOW SENSOR PACKAGE For use with IQS Electronic Water Treatment Equipment Controller REGENERATION CONTROLS Product Description XLF Flow Sensor Iron Saddle The XLF flow sensor package is an input device for the IQS type controller used to measure treated water flow. Flow data then provides one or all of the following functions: •repeatedly measure and deliver a specified volume of treated water. •digital instantaneous flow rate. •digital instantaneous total treated water usage. Packages are available for use in treated water pipe sizes from 1 inch through 6 inch. A wide variety of installation fittings are available to assure compatibility with many commonly used plumbing materials: •Threaded galvanized •Copper sweat •PVC; CPVC •Iron •Steel The XLF flow sensor package is comprised of: •One (1) paddlewheel insertion type flow sensor element sized for the specified pipe diameter •One (1) installation fitting for the specified pipe type and size. How It Works Copper/Bronze Tees Iron Tee The solid state paddlewheel flow sensor works on a simple, but precise, electromechanical principle. A magnetic rotor positioned in the flow stream spins past a solid state switch which in turn pulses a low voltage DC current proportional to the rate of flow. The rotor design ensures an accurate, repeatable output throughout the sensor's entire operating range with negligible head loss and no cavitation. Features & Benefits PVC Tee Bronze Brazolet •Flow range; 0.3 ft/s to 20 ft/s •Low cost. •Low pressure loss. •Ease of installation and service. •Excellent resistance to corrosion and wear •High accuracy and repeatability. •Compatible with most types of piping materials – PVC, copper, brass, galvanized iron and steel. •Wide range of temperature pressure and flow characteristics. •Low voltage operation. •Tested to NIST standards (National Institute of Standards and Techonology). FLOW SENSOR APPLICATION DATA To select the flow sensor package that best fits your requirements, consider these application parameters: 1. Determine Installation Fitting Type – fittings are available for a variety of piping materials. Installation Fitting Pipe Size – (Inches) 2. Determine Installation Fitting Size – identify the HIGHEST anticipated flow rate which would occur regularly thru EACH tank of a single/multiple tank network. Match this value against those in the MINIMUM and MAXIMUM FLOW column of the Flow Rate Range Table to find the corresponding installation Fitting Pipe Size. 3. Verify Temperature/Pressure Operating Range – the maximum operating pressure for the XLF series flow sensor is dependent on the measured fluid temperature and type of installation fitting. Refer to the Temperature/Pressure Graph for operating range. Refer to OPTIONS paragraph for applications requiring a higher temperature/pressure rating. For Temperature/Pressure Conditions beyond Operating Range of XLF Sensors see OPTIONS Pressure (PSIG) Operating Range Flow Sensors And Installation Fittings up in.10 50 0 500F 1000F We ldo-l ets 2.5 to 8 Iron Saddles 2 to 8 in. les add nS Iro nd sa -let ld-o We tal Me 100 in. /M eta l in. Br on ze 1500F 2000F Cv Factor ■ Flow Rate Range – (GPM) Minimum ▲ Maximum 1 ** 11/4 ** 11/2 ** 39.0 56.0 84.0 0.7 1.2 1.7 44.0 80.0 110.0 2 ** 21/2 *** 3 *** 157.0 273.0 483.0 2.8 4.5 6.9 187.0 298.0 460.0 4 *** 5 *** 6 *** 977.0 1750.0 2846.0 11.9 18.7 27.0 793.0 1247.0 1800.0 8 *** 10 *** 5773.0 10,660.0 47.0 74.0 3118.0 4915.0 ( 200 Me tal Te es 0.5 to 2 ▲ ▲ Choose the Installation Fitting Pipe Size principally on the MINIMUM flow rate that would occur REGULARLY in the treated water stream of each water treatment tank. DO NOT OVERSIZE THE INSTALLATION FITTING! ■ C = flow rate (GPM) @ 1.0 psi head loss; 60°F water temperature. V includes worst case requirement of 50 pipe diameters before and 5 pipe diameters following the flow sensor location assuring minimum flow turbulence. Temperature/Pressure Relationship Table 150 ** Threaded Tee Sch 40 Galv. Pipe *** Cast Iron Saddle Sch 40 Pipe Flow Rate Range Table Flow Sensor Selection 2500F Operating Temperature *Number of pipe Specifications diameters required Pressure Loss @ maximum rated flow: Less adjacent to flow than 3.5 psig. See formula † sensor location • includes head loss of required straight length dependent on source of pipe both before and after flow sensor of upstream turbulence: location.(maximum requirement –55 diameters) Electrical Output: C Factor:■ See Flow Range *Requires DC Current V Table from IQS/3;+5VDC @ 10 ma. Flow Rate Range: 0.3 thru 20 feet per second fluid velocity Environmental: Ambient temperature Output Linearity: ± 1% of maximum Relative Humidity: range Accuracy: ± 1% of maximum range Repeatability: ± 0.5% of full range Wetted Materials: Polypropylene, Viton, Titanium, PVDF † PRESSURE LOSS FORMULA (S.G.=1.0) Flow (GPM) ( Actual ) = Pressure Loss @ Actual Flow C Factor ■ (PSI) (GPM) V Options Installation Fitting Service Plug: Allows resumption of flow after depressurization and removal of flow sensor element. Wet Tap Assembly: Provides a safe and fast method of removing a flow sensor element without shutting off flow and pressure. (Maximum Pressure – 100 psig @ 680F; Maximum Temperature – 140°F @ 25 psig) ) *Maximum Temperature: 185°F @ 25 psig *Maximum Pressure: 180 psig @ 680F Installation Requirements: *Maximum wire length 200 ft. –contact between sensor and factory for greater IQS/3 Controller distance requirements 15 minimum/ 55 maximum Open Collector, transistor, sinking -40F to 1220F 0% to 100% Non-condensing Dimensions: X: 1/2" thru 4" = 3.50" 5" thru 8" = 5.00" 10" up = 7.75" *Refer to table for temperature/pressure/ installation fitting relationships. High Temperature/Pressure Applications: Contact factory for pressures up to 1,500 psig and temperatures up to 300°F for stainless steel flow sensors. TM Commercial Systems ©2000 Culligan International Co. 1-800-CULLIGAN www.culligan.com DCO 992196 Printed in USA 01/00 SL-0064 Moore Part No. 49004 Limited WARRANTY Culligan® Hi-Flo® 2 and 2e Series, Hi-Flo® 52 series, Hi-Flo® 42 Series, Hi-Flo® 55e Series, CSM Series and Hi-Flo® 50 Series You have just purchased one of the finest water conditioners made. As an expression of our confidence in Culligan International Company products, this product is warranted to the original end-user, when installed in accordance with Culligan specifications, against defects in material and workmanship from the date of original installation, as follows: For a period of ONE YEAR The entire conditioner. For a period of TWO YEARS The control valve internal parts. The brine valve and its component parts. The salt storage container internal components. For a period of FIVE YEARS The The The The For a period of TWELVE YEARS The conditioner tank, if it contains a plastic liner. control valve body, excluding internal parts. fiberglass wound container(s), if so equipped*. salt storage container(s), if so equipped. epoxy-lined steel conditioner tank(s), if so equipped. * The tank must be protected by a vacuum breaker device as described in the unit's operating manual. Damage to the tank caused by vacuum is not covered by this warranty. The unit must be used in operating conditions that conform to Culligan's recommended design guidelines. This warranty will not apply if the unit has been modified, repaired or altered by someone not authorized by Culligan. If a part described above is found defective within the specified period, you should notify your independently operated Culligan dealer and arrange a time during normal business hours for the dealer to inspect the water conditioner on your premises. Any part found defective within the terms of this warranty will be repaired or replaced by the dealer. You pay only freight from our factory and local dealer charges. We are not responsible for damage caused by accident, fire, flood, freezing, Act of God, misuse, misapplication, neglect, oxidizing agents (such as chlorine, ozone, chloramines and other related components), alteration, installation or operation contrary to our printed instructions, or by the use of accessories or components which do not meet Culligan specifications, is not covered by this warranty. Refer to the specifications section in the Installation and Operating manual for application parameters. Our product performance specifications are furnished with each water conditioning unit. TO THE EXTENT PERMITTED BY LAW, CULLIGAN DISCLAIMS ALL IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION WARRANTIES OF MERCHANTABILITY AND FITNESS FOR PARTICULAR PURPOSE; TO THE EXTENT REQUIRED BY LAW, ANY SUCH IMPLIED WARRANTIES ARE LIMITED IN DURATION TO THE ONE-YEAR PERIOD SPECIFIED ABOVE FOR THE ENTIRE CONDITIONER. As a manufacturer, we do not know the characteristics of your water supply or the purpose for which you are purchasing this product. The quality of water supplies may vary seasonally or over a period of time, and your water usage rate may vary as well. Water characteristics can also differ considerably if this product is moved to a new location. For these reasons, we assume no liability for the determination of the proper equipment necessary to meet your requirements, and we do not authorize others to assume such obligations for us. Further, we assume no liability and extend no warranties, express or implied, for the use of this product with a nonpotable water source or a water source which does not meet the conditions for use described in the installation and operation manual(s) that accompany the equipment. OUR OBLIGATIONS UNDER THIS WARRANTY ARE LIMITED TO THE REPAIR OR REPLACEMENT OF THE FAILED PARTS OF THE WATER CONDITIONER, AND WE ASSUME NO LIABILITY WHATSOEVER FOR DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, SPECIAL, GENERAL, OR OTHER DAMAGES. Some states do not allow the exclusion of implied warranties or limitations on how long an implied warranty lasts, so the above limitation may not apply to you. Similarly, some states do not allow the exclusion of incidental or consequential damages, so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state. Consult your telephone directory for your local independently operated Culligan dealer, or write Culligan International Company for warranty and service information. CULLIGAN INTERNATIONAL COMPANY One Culligan Parkway Northbrook, Illinois 60062 PN 01016557 Printed in U.S.A. Hi-Flo 55e CAD File: Hi-Flo 55e Depth Single.dwg Hi-Flo 55e CAD File: Hi-Flo 55e Depth Duplex.dwg Hi-Flo 55e CAD File: Hi-Flo 55e Depth Triplex.dwg Hi-Flo 55e CAD File: Hi-Flo 55e Depth Quad.dwg Hi-Flo 55e CAD File: Hi-Flo 55e Carbon Single.dwg Hi-Flo 55e CAD File: Hi-Flo 55e Carbon Duplex.dwg Hi-Flo 55e CAD File: Hi-Flo 55e Carbon Triplex.dwg Hi-Flo 55e CAD File: Hi-Flo 55e Carbon Quad.dwg Hi-Flo 55e - Use for Cullsorb Only CAD File: Filt_HF55.dwg
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : Yes Modify Date : 2004:02:23 14:49:12-06:00 Create Date : 2000:08:07 15:47:07-05:00 Subject : Spring 2004 Page Count : 19 Has XFA : No Page Mode : UseOutlines Page Layout : SinglePage Mod Date : 2004:02:23 14:49:12-06:00 Creation Date : 2000:08:07 15:47:07-05:00 Author : KSR Producer : Acrobat PDFWriter 3.02 for Windows Metadata Date : 2004:02:23 14:49:12-06:00 Title : Hi-Flo 55 Filters Description : Spring 2004 Creator : KSREXIF Metadata provided by EXIF.tools