DIGI SINGAPORE IB3500 RF BS COMBO User Manual
Teraoka Weigh-System Pte Ltd. RF BS COMBO
User manual
SERVICE MANUAL IB-3500 RF BASE STATION IB-3500 Tentative Edition COPYRIGHT © 2005 TERAOKA WEIGH-SYSTEM PTE LTD Table of Content i) Notice .....................................................................................................................1 ii) Safety Information ..................................................................................................2 iii) Safety Regulations .................................................................................................2 1. General .............................................................................................................................5 1.1 Model Specification ................................................................................................5 1.2 Operating Specification ..........................................................................................6 2. Dimension ........................................................................................................................7 3. IB-3500 Station Setup Diagram & Spec Setting ............................................................8 3.1 Setup Diagram ........................................................................................................8 3.2 RF Station Setup ....................................................................................................9 4. Revision Records .......................................................................................................... 11 i) Notice DIGI® The material contained in this document is proprietary and for information only and is subject to change without notice. Teraoka Weigh-System assumes no responsibility for any errors or damages arising from misinterpretation of any procedure. Screen displays, operating procedures and supporting features might vary with different software version releases. This document shall not be reproduced whether in part or whole without the written consent from Teraoka Weigh-System Pte Ltd. Teraoka Weigh-System Pte Ltd 4, Leng Kee Road #06-01 SIS Building Singapore 159088 ii) Safety Information The operator of the equipment shall comply with the safety and warning indications and procedures outlined in this document. Teraoka Weigh-System Pte Ltd assumes no responsibility or liability for failure to comply with these requirements. • Repair and servicing of product, shall only be carried out by trained and qualified personnel. Disclaimer: Specifications are subject to change without notice. All dimensions shown are approximate. Please be aware that Teraoka has indicated that its hardware and software used in the product may require additional updates in the future as our product is continually under development. The need for such updates most likely applies to the Printer software. CAUTIONS: FOR PLUGGABLE EQUIPMENT, THAT THE SOCKET-OUTLET SHALL BE INSTALLED NEAR THE EQUIPMENT AND SHALL BE EASILY ACCESSIBLE. POUR LE MATÉRIEL RACCORDÉ PAR PRISE DE COURANT, LE SOCLE DE PRISE DE COURANT DOIT ÊTRE INSALLÉ À PROXIMITÉ DU MATÉRIEL ET DOIT ÊTRE AISÉMENT ACCESSIBLE. FOR CONTINUED PROTECTION AGAINST RISK OF FIRE, REPLACE ONLY WITH SAME TYPE AND RATING OF FUSE. POUR NE PAS COMPROMETTRE LA PROTECTION CONTRE LES RISQUES D’INCENDIE, REMPLACER PAR UN FUSIBLE DE MÊME TYPE ET DE MÊME CARACTÉRISTIQUES NOMINALES. DANGER OF EXPLOSION IF BATTERY IS INCORRECTLY REPLACED. REPLACE ONLY WITH THE SAME OR EQUIVALENT TYPE RECOMMENDED BY THE MANUFACTURER. DISCARD USED BATTERIES ACCORDING TO THE MANUFACTURER’S INSTRUCTIONS IL Y A DANGER D’EXPLOSION S’IL Y A REMPLACEMENT INCORRECT DE LA BATTERIE. REMPLACER UNIQUEMENT AVEC UNE BATTERIE DU MÊME TYPE OU D’UN TYPE RECOMMANDÉ PAR LE CONSTRUCTEUR. METTRE AU RÉBUT LES BATTERIES USAGÉES CONFORMÉMENT AUX INSTRUCTIONS DU FABRICANT. iii) Safety Regulations Federal Communication Commission Interference Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. IMPORTANT NOTE: FCC Radiation Exposure Statement: This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. IDA Compliance Statement: (Singapore) This equipment registered to comply with IDA (Info-Communications Development Authority of Singapore) Standard under Dealer’s Class License. Actual size 9mm (H) x 17mm (W) Industry Canada statement: This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. IMPORTANT NOTE: Radiation Exposure Statement: This equipment complies with IC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body. Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement. Déclaration d'exposition aux radiations: Cet équipement est conforme aux limites d'exposition aux rayonnements IC établies pour un environnement non contrôlé. Cet équipement doit être installé et utilisé avec un minimum de 20 cm de distance entre la source de rayonnement et votre corps. For Taiwan 警語: 經型式認證合格之低功率射頻電機,非經許可,公司、商號或使用者均不得擅自變更頻率、加 大功率或變更原設計之特性及功能。 低功率射頻電機之使用不得影響飛航安全及干擾合法通信;經發現有干擾現象時,應立即停 用,並改善至無干擾時方得繼續使用。前項合法通信,指依電信法規定作業之無線電通信。低 功率射頻電機須忍受合法通信或工業、科學及醫療用電波輻射性電機設備之干擾 IB-3500 Base Station Service Manual 1. General 1.1 Model Specification Model IB-3500 Dimensions (in mm) Body Casing Dimension With Upright Antenna - 230(L) x 210(W) x 51(H) - 230(L) x 210(W) x 205.5(H) Color White LED (x4) Red Green Orange Red Reset Button 1 x Mechanical Switch Antenna (x4) Antenna Color (White) 2 x Transmit Data (TX) 2 x Receive Data (RX) Weight 1500g approx. Operating System Linux Power Source Ethernet Cable from POE Switch Port (48 Volt DC) Voltage & Current DC 48V, 0.35A Operating Temperature Ranges 10ºC to +40ºC Operating Humidity 85% Max. Non-condensing I/O Interface Ethernet 10/100 Base T Housing Material Powder Coated SPCC Metal Sheet Power Indicator Data Transmit Indicator Data Receive Indicator System Busy Indicator IB-3500 Base Station Service Manual 1.2 DC Specification Power Source External : Internal Operating Temperature 10ºC to +40ºC Humidity 85% Max. Non-condensing 1.3 Ethernet Cable from POE Switch Port (48 Volt DC) NA RF Specification RF Standard FCC ARIB STD-T66 NCC, C-TICK, IC, CE Modulation GFSK, MSK Frequency Band 2.402GHz to 2.475GHz Channel list 73 Channels Transmit Power 16.35dBm (GFSK) 8.58dBm (MSK) Receiver Sensitivity -90dBm (typical), PER = 1% IB-3500 Base Station Service Manual 2. Dimension “R”ound projection denotes “Receiver” Antenna 210 230 51 205.5 “R”ound projection denotes “Receiver” Antenna IB-3300 Base Station Service Manual 3. IB-300 Station Setup Diagram & Spec Setting 3.1 Setup Diagram Front View Top View ANTENNA TX LED RX LED Power LED Reset Button Reset LED Ethernet (POE Port) LED / BUTTON Power LED (Red) • Power On Indicator. Descriptions TX LED (Green) • The indicator light will be stay ‘On’ or ‘Blinking’, when Transmit Data communication is connected. RX LED (Orange) • The indicator light will be stay ‘Toggle’, when Receive Data communication is connected. Reset LED (Red) • The indicator light will be on a time when press the reset switch. The indicator light will be “on off” or “off on” when data busy. • Reset Button • To reset the program when programming running error is appear. Ethernet (POE Port) • For RF Station power input voltage go through Ethernet LAN cable. Transmit/Receive the data with Info Server (CT-3100) • IB-3300 Base Station Service Manual 3.2 RF Station Setup Ethernet Straight Cable Ethernet Straight Cable POE Switch PC RF Station PROCEDURE PICTURE 1) Double click open the [Internet Explorer] icon. 2) In the Web Browser, key in the RF Station IP address [192.168.50.49] accesses to RF Station Setting main screen. Note: 192.168.50.49 is Default IP Address 3) In the RF Station Setting main screen, keying the new “IP Address” and “Network Mask”. After that click [Submit] to save change the setting. Example New IP Address: 192.168.50.XXX Note: Click [Reset] will cancel the setting changed. 4) After finish new setting changed need to plug out the Ethernet cable from POE switches and then plug in again to implement the new setting. Ethernet Cable IB-3300 Base Station Service Manual 5) Repeat the Step 2, and keying the new IP Address to checking the setting is changed. Note: Ensure the PC IP Address is also change to under same network. (Example: 192.168.50.123) 10 IB-3100 Base Station Service Manual 4. Revision Records Serial No. Date Edition Status 001 DEC ‘13 00 First Release NA 002 JAN’13 00 Update IC statements NA Description of Changes 11 Software Version Remarks
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : Yes Encryption : Standard V4.4 (128-bit) User Access : Print, Extract Author : OngSG Create Date : 2014:01:21 15:04:10+08:00 Modify Date : 2014:01:21 15:04:14+08:00 Subject : Tagged PDF : Yes XMP Toolkit : Adobe XMP Core 5.4-c005 78.147326, 2012/08/23-13:03:03 Metadata Date : 2014:01:21 15:04:14+08:00 Creator Tool : Acrobat PDFMaker 11 Word 版 Document ID : uuid:b7a60775-966f-430e-a8ef-73d6c8fb7d06 Instance ID : uuid:a381c9a9-5d45-4569-8e65-b7e4c4e6f7ca Format : application/pdf Title : Description : Creator : OngSG Producer : Adobe PDF Library 11.0 Keywords : Source Modified : D:20140121070115 Company : Sporton Page Layout : OneColumn Page Count : 13EXIF Metadata provided by EXIF.tools