DT Research 800G Medical Cart Computer User Manual DT59X users manual for FCCCE

DT Research, Inc. Medical Cart Computer DT59X users manual for FCCCE

User Manual

Download: DT Research 800G Medical Cart Computer User Manual DT59X users manual for FCCCE
Mirror Download [FCC.gov]DT Research 800G Medical Cart Computer User Manual DT59X users manual for FCCCE
Document ID2936142
Application IDI93MDRNW8xMQs+G5BBJrEQ==
Document DescriptionUser Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize31.06kB (388312 bits)
Date Submitted2016-03-21 00:00:00
Date Available2016-03-22 00:00:00
Creation Date2016-03-18 09:18:54
Producing SoftwareAcrobat Distiller 9.0.0 (Windows)
Document Lastmod2016-03-18 09:19:09
Document TitleMicrosoft Word - DT59X users manual for FCCCE
Document CreatorPScript5.dll Version 5.2.2
Document Author: Jinn-pc_2

DT590B/ DT592B/DT594B
BASIC OPERATION GUIDE
ENGLISH
INTRODUCTION
Thank you for acquiring DT Research’s medical cart computer medical cart computer. With a 19-inch,
22-inch or 24-inch TFT display and powered by the Intel Core™ i7 processor, the medical cart computer
offers optimal combinations of performance and power savings. With fully-integrated point-of-care modules
within an elegant, space-saving design, the medical cart computer is the optimum solution to enhance
workflow and service.
Please take a few moments to review the contents of this document to ensure that the setup and startup
proceed smoothly. The medical cart computer medical cart computer is ready for use, out of the box, in its
default configuration when powered by the power source provided. The following discussion offers guidance
on the hardware elements and features of the computer. Please refer to your device provider for information
pertaining to the software operating system or software applications.
Package Contents
One DT590B, DT592B or DT594B
Three DR202 Li-ion batteries (optional)
AC-DC power adapter with power cord
Basic operation guide
DT590B/ DT592B/ DT594B
I/O Ports:
The medical cart computer has a comprehensive set of I/O ports. The following ports are located along the lower rear
edge of the display unit.
Cleaning the Screen:
• A screen cleaning solution that is non-alcohol and non-abrasive can be used to clean the touch screen.
• We suggest cleaning with a micro-fiber cloth.
• Please spread the solution on to the cloth and then clean the touch screen.
Cleaning the Anti-microbial Enclosure:
• Use a soft/non‐abrasive cloth moistened with water to clean the enclosure.
• If using a cleaner, an alcohol‐free and oxide‐free cleaning liquid is recommended.
• To prevent scratching the anti‐microbial coating, please wipe gently.
ENGLISH
DT590B/ DT592B/ DT594B
Precautions:
Always exercise care when operating • and handling the medical cart computer.
•
Never disassemble any portion of the enclosure, as this will void any product warranty on the medical cart computer.
•
Do not use any AC/DC adapter other than the one provided with the device or a replacement acquired from the
manufacturer.
•
In the unlikely event that smoke, abnormal noise or strange odor is present, immediately power down the medical
cart computer and disconnect all power sources. Please report the problem to your device provider immediately.
Basic Features
The medical cart computer integrates a bright 19”, 22” or 24” display with optional capicitive touch, USB ports, and is
complemented by a smart card reader option for comprehensive point-of-care applications.
Powering ON and OFF
If your medical cart computer comes with the battery packs, please open the battery slot caps and then put in the battery
packs one by one. If not, please use the AC-DC adapter with the medical cart computer for the power supply. To activate
the medical cart computer, push and quickly release the Power Button and the display will come on in a few seconds. To
put in Standby mode, push and quickly release the Power Button. To turn off for extended storage, power off the device
safely using any software function that “shuts down computer” provided in the software operating system.
NOTE:
The battery packs shipped with your device may be low in power—please use the AC-DC adapter with
the medical cart computer when setting up the device for the first time to fully charge the internal battery
packs.
NOTE:
When the battery pack(s) is (are) charging, the blue-colored Battery LED should blink slowly. If plugging
in the AC-DC adapter does not trigger this blinking activity and the LED stays dark, the battery pack(s)
may have been drained substantially. Try unplugging/ replugging the AC-DC adapter to the medical cart
computer a few times to activate the charging process.
NOTE:
To conserve power, use (push and quick release) the Power Button to put the device in “Standby”mode
while not in use. Pushing briefly on the same button will wake up the system within seconds.
NOTE:
Avoid using the Power Button (“hold 4+ seconds” feature) to turn off the device—this form of hardware
shutdown is intended to be a means of recovery from device lockups, and not as normal operation.
ENGLISH
DT590B/ DT592B/ DT594B
Power/Battery LED Status
• Blue indicates the battery is 25% to 100% charged
• Blinking blue indicates the battery is charging
• Orange indicates that the battery is between 11% to 25%
• Blinking Orange indicates that the battery is below 10%
Wireless Networking
Wireless LAN
The medical cart computer is often delivered with an embedded (user-inaccessible) 802.11ac WLAN adapter equipped
with a hidden custom antenna.
•
Through the support of typical WLAN adapters, the medical cart computer should be able to detect all 802.11
access points in the vicinity for you to select the access point of your choice for connection.
•
The SSID and WEP/WPA/WPA2 (if enabled) parameters on the medical cart computer and the access points have
to match. The SSID is case-sensitive and it is recommended that you enable WEP/WPA/WPA2 encryption (or
advanced alternatives) for secure access.
•
When WEP/WPA/WPA2 is enabled, you may need to consult your network administrator or your networking
equipment literature to properly configure associated settings such as Authentication mode, etc.
•
Refer to the access point operating manuals for setting up the 802.11 access points.
Bluetooth
The medical cart computer features a built-in Bluetooth adapter that operates on the Microsoft Windows Bluetooth
protocol. The Bluetooth configuration application is invoked from the System Tray or from the Control Panel. Follow the
instructions and options provided within the application to configure and invoke Bluetooth connectivity with the
corresponding peripherals.
NOTE:
Bluetooth devices or accessories that are not compatible with the Microsoft Windows Bluetooth protocol
may not work with the medical cart computer.
ENGLISH
DT590B/ DT592B/ DT594B
SPECIFICATIONS:
Iten
CPU
RAM
Storage
Operating
System
Display
Display
Resolution
Touch Screen
Network
Interface
Bluetooth
Control Buttons
Speaker
DT590B
DT592B
DT594B
Intel® Core™ i7, 2.4GHz
Intel® Core™ i7, 2.4GHz
Intel® Core™ i7, 2.4GHz
4GB to 16GB
4GB to 16GB
4GB to 16GB
64GB to 256GB Flash
64GB to 256GB Flash
64GB to 256GB Flash
Microsoft® Windows® 7 Professional 或 Windows® 8.1 Pro Industry
19" TFT-LCD
21.5" TFT-LCD
23.6" TFT-LCD
1280 X 1024
1920 X 1080
1920 X 1080
Optional capacitive touch
Optional capacitive touch
Optional capacitive touch
Ethernet 10/ 100/ 1000 MB Base-T LAN; Wi-Fi 802.11ac, 2.4GHz/ 5GHz dual band;
Bluetooth 4.0 LE
Bluetooth 4.0 LE
Bluetooth 4.0 LE
5 side buttons: 1 power and 4 functional
5 side buttons: 1 power and 4 functional
5 side buttons: 1 power and 4 functional
buttons
buttons
buttons
Built-in speaker
Built-in speaker
Built-in speaker
2 (USB 2.0),4 (USB 3.0)
2 (USB 2.0),4 (USB 3.0)
2 (USB 2.0),4 (USB 3.0)
RJ45 connector for Ethernet x 1
RJ45 connector for Ethernet x 1
RJ45 connector for Ethernet x 1
DR202 Li-ion battery; 10.9V, 7800mA x 3
DR202 Li-ion battery; 10.9V, 7800mA x 3
DR202 Li-ion battery; 10.9V, 7800mA x 3
(optional)
(optional)
(optional)
Input: 100 – 240V AC;
Input: 100 – 240V AC;
Input: 100 – 240V AC;
I/O Ports
USB Port
COM Port
HDMI (1.4a)
Microphone-in
Audio-out
Ethernet
DC-in
Mechanical and Environmental
Battery Pack
AC/DC Adapter
Enclosure
Dimensions
(H x W x D)
Weight
Temperature
Humidity
Output: 19V DC, 6.31A
Output: 19V DC, 6.31A
Output: 19V DC, 6.31A
ABS + PC plastics, anti-microbial plastics
ABS + PC plastics, anti-microbial plastics
ABS + PC plastics, anti-microbial plastics
14.9 x 17.7 x 2.2 in/ 380 x 450 x 65mm
12.5 x 20.8 x 2.3 in/ 318 x 529 x 58 mm
14.2 x 22.9 x 2.3 in/ 361 x 582 x 57 mm
14.3 lbs/ 6.5 kg
20.5 lbs/ 9.3 kg
15.4 lbs/ 7kg
Operation: 0°C – 40°C; Storage: -20°C – 60°C
0% – 90% non-condensing
DT Research, Inc.
2000 Concourse Drive, San Jose, CA 95131
http://www.dtresearch.cn
Copyright © 2015, DT Research, Inc. All Rights Reserved.
ENGLISH
BOG08241559XEN
FCC Regulations:
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1)
This device may not cause harmful interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
This device has been tested and found to comply with the limits for a Class B digital device, pursuant to Part
15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in
a residential installation. This equipment generates, uses and can radiated radio frequency energy and, if not
installed and used in accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not occur in a particular installation If
this equipment does cause harmful interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of
the following measures:
‐Reorient or relocate the receiving antenna.
‐Increase the separation between the equipment and receiver.
‐Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
‐Consult the dealer or an experienced radio/TV technician for help.
Changes or modifications not expressly approved by the party responsible for compliance could void the user‘s
authority to operate the equipment.
RF Exposure Warning
This equipment must be installed and operated in accordance with provided instructions and the antenna(s)
used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons
and must not be co‐located or operating in conjunction with any other antenna or transmitter. End‐users and
installers must be provide with antenna installation instructions and transmitter operating conditions for
satisfying RF exposure compliance.

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : Yes
Author                          : Jinn-pc_2
Create Date                     : 2016:03:18 09:18:54+08:00
Modify Date                     : 2016:03:18 09:19:09+08:00
XMP Toolkit                     : Adobe XMP Core 4.2.1-c041 52.342996, 2008/05/07-20:48:00
Format                          : application/pdf
Creator                         : Jinn-pc_2
Title                           : Microsoft Word - DT59X users manual for FCCCE
Creator Tool                    : PScript5.dll Version 5.2.2
Metadata Date                   : 2016:03:18 09:19:09+08:00
Producer                        : Acrobat Distiller 9.0.0 (Windows)
Document ID                     : uuid:dc0a4bb7-baf8-4f4c-a18f-ed212ab2912f
Instance ID                     : uuid:970051b8-f6c2-4e7b-8685-77debbfa29b1
Page Count                      : 7
EXIF Metadata provided by EXIF.tools
FCC ID Filing: YE3800G

Navigation menu