Danfoss A S TYPE-CFR Wireless Floor Heating Control System User Manual Vi 88 R1 03
Danfoss A/S Wireless Floor Heating Control System Vi 88 R1 03
Contents
- 1. Users Guide
- 2. Installation Instructions
Users Guide
Temperature setting Set room temperature on the thermostat dial. Limitation of the setting range Behind the button for temperature setting are two lock-rings. These can be moved as shown if the thermostat setting range is to be narrowed. On the right-hand side of the thermostat is a function switch with 3 possible settings: Room Thermostat User Guide ¹ Typ CFR The room temperature will be as set on the thermostat. Used only if the zone regulator is engaged. The temperature will be as set on the room thermostat, but in accordance with the consumption pattern entered. The consumption pattern in the zone regulator can be overridden by moving the switch to or . The room temperature will be as set on the thermostat - minus 5°C. FCC ID: XXXTYPE.CFR This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. Warning: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. “This device complies with RSS-210 of Industry Canada. Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device.” Li 3,6V/1,9Ah Room Thermostat Instructions for Installation Registration field in master regulator 088R0223 DKCD 01/00 VI.88.R1.02 Typ CFR Registration of room thermostat with output(s) - Connect the room thermostat (fig. 1) and the CFM master regulator via the black installation cable. The first vacant output in the registration field will flash. Other vacant outputs will be lit. Outputs already registered are not on (fig. 2). - If OK is pressed briefly, the room thermostat has been registered with the output and the LED goes off (fig. 2). - If the room thermostat is to be registered with more than one output, go to these outputs by means of the +/- keys and confirm by pressing OK briefly. - When the installation cable is removed, the red LED underneath the battery cover (fig. 1) will flash for at least one minute (Test mode). Unregistration of room thermostat The room thermostat and the master regulator may not be connected. -Press OK for 5 sec.; the first LED in the row for registered room thermostats will flash (fig. 2). Other LEDs for registered room thermostats will flash. - Use the +/- keys to go to the room thermostat to be unregistered (it will flash). - Confirm unregistration by pressing OK for 5 sec.. The LED goes off. Test of room thermostat If a defect in a room thermostat is suspected, the following test may be carried out: - Set the thermostat to the highest temperature (EC). - Move the function switch on the side of the room thermostat to a new position. - If the LED underneath the battery cover (fig. 1) flashes quickly for at least one minute, the room thermostat is in order.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.3 Linearized : No Create Date : 2000:01:27 10:19:20 Producer : Acrobat Distiller 4.0 for Windows Subject : Vi.88.R1.03 Author : F10389 Creator : Adobe PageMaker 6.52 Title : Vi.88.R1.03 Modify Date : 2000:01:27 10:19:21+01:00 Page Count : 2EXIF Metadata provided by EXIF.tools