Danfoss A S TYPE-CFR Wireless Floor Heating Control System User Manual Vi 88 R1 03
Danfoss A/S Wireless Floor Heating Control System Vi 88 R1 03
Contents
- 1. Users Guide
- 2. Installation Instructions
Users Guide

Room Thermostat
User Guide
Typ CFR
Temperature setting
Set room temperature on the thermostat dial.
On the right-hand side of the thermostat is a
function switch with 3 possible settings:
The room temperature will be as set
on the thermostat.
Used only if the zone regulator is en-
gaged. The temperature will be as set
on the room thermostat, but in accor-
dance with the consumption pattern
entered.
The consumption pattern in the zone
regulator can be overridden by moving
the switch to or .
The room temperature will be as set
on the thermostat - minus 5°C.
Limitation of the setting range
Behind the button for temperature setting are two
lock-rings. These can be moved as shown if the
thermostat setting range is to be narrowed.
¹
Warning: Changes or modifications to this unit not
expressly approved by the party responsible for
compliance could void the user’s authority to operate
the equipment.
“This device complies with RSS-210 of Industry Ca-
nada. Operation is subject to the following two condit-
ions: (1) this device may not cause interference, and (2)
this device must accept any interference, including
interference that may cause undesired operation of the
device.”
FCC ID: XXXTYPE.CFR
This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) This device must accept any interference received,
including interference that may cause undesired opera-
tion.

2
3
1
Li 3,6V/1,9Ah
088R0223 DKCD 01/00 VI.88.R1.02
Registration field in
master regulator
Room Thermostat
Instructions for Installation
Typ CFR
Registration of room thermostat with output(s)
- Connect the room thermostat (fig. 1) and the CFM mas-
ter regulator via the black installation cable. The first va-
cant output in the registration field will flash. Other va-
cant outputs will be lit. Outputs already registered are
not on (fig. 2).
- If OK is pressed briefly, the room thermostat has been
registered with the output and the LED goes off (fig. 2).
- If the room thermostat is to be registered with more than
one output, go to these outputs by means of the +/- keys
and confirm by pressing OK briefly.
- When the installation cable is removed, the red LED un-
derneath the battery cover (fig. 1) will flash for at least
one minute (Test mode).
Unregistration of room thermostat
The room thermostat and the master regulator may not
be connected.
-Press OK for 5 sec.; the first LED in the row for regis-
tered room thermostats will flash (fig. 2). Other LEDs for
registered room thermostats will flash.
- Use the +/- keys to go to the room thermostat to be un-
registered (it will flash).
- Confirm unregistration by pressing OK for 5 sec.. The
LED goes off.
Test of room thermostat
If a defect in a room thermostat is suspected, the follow-
ing test may be carried out:
- Set the thermostat to the highest temperature (EC).
- Move the function switch on the side of the room ther-
mostat to a new position.
- If the LED underneath the battery cover (fig. 1) flashes
quickly for at least one minute, the room thermostat is in
order.