Danfoss A S TYPE-CFR Wireless Floor Heating Control System User Manual Vi 88 R1 03

Danfoss A/S Wireless Floor Heating Control System Vi 88 R1 03

Contents

Users Guide

Room ThermostatUser GuideTyp CFRTemperature settingSet room temperature on the thermostat dial.On the right-hand side of the thermostat is afunction switch with 3 possible settings:The room temperature will be as seton the thermostat.Used only if the zone regulator is en-gaged. The temperature will be as seton the room thermostat, but in accor-dance with the consumption patternentered.The consumption pattern in the zoneregulator can be overridden by movingthe switch to     or     .The room temperature will be as seton the thermostat - minus 5°C.Limitation of the setting rangeBehind the button for temperature setting are twolock-rings. These can be moved as shown if thethermostat setting range is to be narrowed.¹Warning:  Changes or modifications to this unit notexpressly approved by the party responsible forcompliance could void the user’s authority to operatethe equipment.“This device complies with RSS-210 of Industry Ca-nada.  Operation is subject to the following two condit-ions: (1) this device may not cause interference, and (2)this device must accept any interference, includinginterference that may cause undesired operation of thedevice.”FCC ID:  XXXTYPE.CFRThis device complies with Part 15 of the FCC Rules.Operation is subject to the following two conditions:(1) This device may not cause harmful interference, and(2) This device must accept any interference received,including interference that may cause undesired opera-tion.
231Li 3,6V/1,9Ah 088R0223     DKCD 01/00 VI.88.R1.02Registration field inmaster regulatorRoom ThermostatInstructions for InstallationTyp CFRRegistration of room thermostat with output(s)- Connect the room thermostat (fig. 1) and the CFM mas-ter regulator via the black installation cable. The first va-cant output in the registration field will flash. Other va-cant outputs will be lit. Outputs already registered arenot on (fig. 2).- If OK is pressed briefly, the room thermostat has beenregistered with the output and the LED goes off (fig. 2).- If the room thermostat is to be registered with more thanone output, go to these outputs by means of the +/- keysand confirm by pressing OK briefly.- When the installation cable is removed, the red LED un-derneath the battery cover (fig. 1) will flash for at leastone minute (Test mode).Unregistration of room thermostatThe room thermostat and the master regulator may notbe connected.-Press OK for 5 sec.; the first LED in the row for regis-tered room thermostats will flash (fig. 2). Other LEDs forregistered room thermostats will flash.- Use the +/- keys to go to the room thermostat to be un-registered (it will flash).- Confirm unregistration by pressing OK for 5 sec.. TheLED goes off.Test of room thermostatIf a defect in a room thermostat is suspected, the follow-ing test may be carried out:- Set the thermostat to the highest temperature (EC).- Move the function switch on the side of the room ther-mostat to a new position.- If the LED underneath the battery cover (fig. 1) flashesquickly for at least one minute, the room thermostat is inorder.

Navigation menu