Data Critical 02DR-10110 WMTS OPENNET LAN User Manual 06 10001003 004 B
Data Critical Corporation WMTS OPENNET LAN 06 10001003 004 B
Contents
- 1. Manual admin guide
- 2. Manual user guide
- 3. Installer note
Manual admin guide
WMTS OPENNET LAN PROGRAMMING AND DIAGNOSTICS WMTS OPENNET LAN PROGRAMMING AND DIAGNOSTICS Note: The information in this section is only applicable for Wireless Medical Telemetry Service (WMTS) version of PatientNet. About this Section This section includes instructions for the following tasks: • defining the Device Master (page 103) • viewing OpenNet diagnostics (page 116) • configuring the OpenNet LAN (page 104) • setting Access Point parameters (page 106) • assigning transceivers (page 135) Accessing the OpenNet LAN screen To access the OpenNet LAN screen: 1. Access the Service Screen (page 63). 2. Click the Service button on the System Setup screen. 3. Click the OpenNet button on the Service screen to open the OpenNet LAN screen. If the OpenNet LAN is not enabled on your system, then the OpenNet Status screen (page 136) will display instead of the OpenNet LAN screen. Fig. 60. OpenNet LAN Screen 4. Click the Exit button to close the OpenNet LAN screen and return to the Service screen. PatientNet Administrator’s Guide, v1.04, 10001003-004, Revision B 101 All information contained herein is subject to the rights and restrictions on the title page. WMTS OPENNET LAN PROGRAMMING AND DIAGNOSTICS Description of Buttons and Functions The following section describes the buttons and functions of the OpenNet LAN Screen. Subsequent sections will discuss each function in detail. 102 Button Function Master Designates the system as the Device Master, which controls the user defined parameters on systems throughout the OpenNet LAN (page 103). Diagnostics Displays the OpenNet Diagnostics screen (page 116). System Displays the OpenNet System Configuration screen (page 104). Assign TX Displays the Assign Transceiver screen. (page 135) Program AT Displays the Ambulatory Transceiver (AT), programming screen. (page 123). See the Programming Transceivers (page 122) section for details. Program IT Displays the Instrument Transceiver (IT), programming screen. (page 129). See Programming Transceivers (page 122) for details. Print DM Prints the Device Master report, which displays the global, as well as individual, parameters for each Access Point. LAN Displays the OpenNet LAN Configuration screen, which is allows you to set the OP Band, Ext Sync, and update Access Points (page 104). • This button is only available on the Device Master system. Access Point Displays the Access Point Settings screen, which allows you to configure the Access Point settings (page 106). • This button is only available on the Device Master system. RF Module Displays the RF Module screen, which allows you to configure the RF Module settings (page 111). • This button is only available on the Device Master system. PatientNet Administrator’s Guide, v1.04, 10001003-004, Revision B All information contained herein is subject to the rights and restrictions on the title page. WMTS OPENNET LAN PROGRAMMING AND DIAGNOSTICS Designating a Device Master The Device Master is the system on the OpenNet LAN that controls the user defined parameters. To designate the system as the Device Master: 1. Click the Master button to toggle between Enabled and Disabled (see fig. 60 on page 101). • Selecting Enabled defines the system as the Device Master. Note: Only one Device Master is allowed on the network at one time. To enable a new Device Master, you must first disable the original Device Master, then enable the new Device Master. • Selecting Disabled defines the system as not being the Device Master. 2. Click the Exit button to close the OpenNet LAN screen and return to the Service screen. Printing the Device Master Report The Device Master Report displays the global, as well as individual, parameters for each Access Point. To print the Device Master Report: 1. Click the Print DM button on the OpenNet LAN screen to print the Device Master Report. 2. Click the Exit button to close the OpenNet LAN screen and return to the Service screen. PatientNet Administrator’s Guide, v1.04, 10001003-004, Revision B 103 All information contained herein is subject to the rights and restrictions on the title page. WMTS OPENNET LAN PROGRAMMING AND DIAGNOSTICS Configuring the Device Master You can configure global parameters for the Device Master in the OpenNet LAN Configuration screen. To configure the OpenNet LAN parameters: Note: In order to view the LAN button, the Central Station must be designated as the device master (see “Designating a Device Master” on page 103). 1. Click the LAN button to open the OpenNet LAN Configuration screen (fig. 61). Fig. 61. OpenNet LAN Configuration Screen 2. Click the Ext Sync button to toggle the Access Point synchronization source between Yes and No. • Selecting Yes will designate an external source for providing the synchronization of each Access Point. • Selecting No will designate a single Access Point the task of providing its own synchronization. Note: 104 You can only set the Ext Sync to No for a single Access Point system. PatientNet Administrator’s Guide, v1.04, 10001003-004, Revision B All information contained herein is subject to the rights and restrictions on the title page. WMTS OPENNET LAN PROGRAMMING AND DIAGNOSTICS 3. Click the OP Band button to set the operating band that will be used by the Access Point. • Typically, the 608.5-613.0 OP Band is selected. However, where the PatientNet System operates in the same hospital as another system (or systems) that also use(s) the 608-614 MHz WMTS band, it will be necessary to select one of the sub-bands. The sub-band should coordinate with the hospital’s spectrum policy. • Additional sub-bands include: 608.5-609.7, 609.6-610.8, 610.7-611.9, and 611.8-613.0 WARNING: All transceivers must be programmed to the same OP Band as the Access Points. This is an administrative procedure only. Do not attempt to program the transceivers with the selected OP Band. 4. Click the Update All Access Points button to update any allocated Access Points on the OpenNet LAN with the current configuration data from the Device Master. WARNING: Selecting Update All Access Points will re-configure all Access Points on the network and will affect proper system operation. Do not activate this button on a live system. 5. Click the Exit button to close the OpenNet LAN Configuration screen and return to the OpenNet LAN screen. PatientNet Administrator’s Guide, v1.04, 10001003-004, Revision B 105 All information contained herein is subject to the rights and restrictions on the title page. WMTS OPENNET LAN PROGRAMMING AND DIAGNOSTICS Setting Access Point Parameters You can view and edit the settings for all Access Points on the network with the Access Point Settings screen. To view and edit Access Point settings: Note: In order to view the Access Point button, the system must be designated as the device master (see “Designating a Device Master” on page 103). 1. Click the Access Point button on the OpenNet LAN screen to open the Access Point Settings screen (fig. 62). Fig. 62. Access Point Settings Screen 2. Click the Pg Up, Pg Dn, and arrow buttons to select each Access Point and view its current settings. 3. Click the Edit button to open the Access Point Configuration screen (see “Configuring Access Point Parameters” on page 108). This will allow you to change the selected Access Point’s parameters. 4. Click the Add AP button to open the Access Point Configuration screen and configure the settings for the next available Access Point in sequence (see “Configuring Access Point Parameters” on page 108). 5. Click the Remove button to remove a selected Access Point from the Access Point Settings screen and the OpenNet LAN. • A warning popup will display requesting you to click either Yes, which will remove the selected Access Point, or No, which will close the popup and leave the Access Point unchanged. 106 PatientNet Administrator’s Guide, v1.04, 10001003-004, Revision B All information contained herein is subject to the rights and restrictions on the title page. WMTS OPENNET LAN PROGRAMMING AND DIAGNOSTICS 6. Click the Exit button to close the Access Point Settings screen and return to the OpenNet LAN screen. The columns in the Access Point Settings screen are described below AP displays the access point for each configured RF Module on the OpenNet LA. Note: An asterix (*) next to the AP number indicates that the Access Point is active in the Device Master. displays the 24 bit ID number for the RF Module that is located in the first slot of the Access Point displays the 24 bit ID number for the RF Module that is located in the Slot 2 second slot of the Access Point IP Address displays the IP address for an Access Point Slot 1 Location displays each Access Point’s location. PatientNet Administrator’s Guide, v1.04, 10001003-004, Revision B 107 All information contained herein is subject to the rights and restrictions on the title page. WMTS OPENNET LAN PROGRAMMING AND DIAGNOSTICS Configuring Access Point Parameters You can configure the parameters for each Access Point on the OpenNet LAN with the Access Point Configuration screen. This screen also allows you to configure the parameters for Access Points that have been added to the network. To configure Access Point parameters: Note: In order to view the Access Point button, the system must be designated as the device master (see “Designating a Device Master” on page 103). 1. Click the Access Point button on the OpenNet LAN screen to open the Access Point Settings screen (see fig. 62 on page 106). 2. Select the Access Point that you would like to configure and click the Edit button to open the Access Point Configuration screen (fig. 63). Note: Clicking the Add AP button on the Access Point Settings screen displays the Access Point Configuration screen for the next available, currently unassigned, Access Point on the system. This allows you to configure and add the new AP to the system. Fig. 63. Access Point Configuration Screen 3. Select the desired Access Point number by clicking the up and down arrows, which will cycle through the available Access Points and update the fields with settings for each selected Access Point. 4. Click the RF Modules button to toggle the RF Module setting between 1 and 2. The RF Module setting defines the number of RF Modules that reside in the selected Access Point. 5. Click the IP Address button to open a keypad with which you can set the IP address for the selected Access Point. 108 PatientNet Administrator’s Guide, v1.04, 10001003-004, Revision B All information contained herein is subject to the rights and restrictions on the title page. WMTS OPENNET LAN PROGRAMMING AND DIAGNOSTICS 6. Click the Location button to open the Location popup (fig. 64), which allows you to enter the Access Point’s location Fig. 64. Access Point Default Location Popup 7. Click the Defaults button to return the selected Access Point’s settings to the system default configuration. 8. Click the Mod Config button to open the RF Module Configuration screen (see “Configuring RF Module Parameters” on page 113), which allows you to configure the RF Module for the selected Access Point. 9. Click the Update AP button to update the selected Access Point device with the new configuration data. Note: During the Update process, the Access Point will not be active. 10. Click the Next button to display the Access Point Configuration Page 2 screen (page 110). 11. Click the Exit button to close the Access Point Configuration screen and return to the Access Point Settings screen. PatientNet Administrator’s Guide, v1.04, 10001003-004, Revision B 109 All information contained herein is subject to the rights and restrictions on the title page. WMTS OPENNET LAN PROGRAMMING AND DIAGNOSTICS Configuring Access Point Parameters - Part 2 The second page of the Access Point Configuration screen allows you to configure additional Access Point parameters. 1. Click the Next button on the Access Point Configuration screen (see “Access Point Configuration Screen” on page 108) to open the Access Point Configuration Page 2 screen (page 110). Fig. 65. Access Point Configuration Screen - Part 2 2. Select the desired Access Point number by clicking the up and down arrows, which will cycle through the available Access Points and update the fields with settings for each selected Access Point. 3. Click the Default Gateway button to open a keypad that allows you to set a valid gateway address for the selected Access Point. This button is for administrative purposes only. Do not attempt to set the Default Gateway. 4. Click the Subnet Mask button to open a keypad with which you can enter the OpenNet LAN subnet mask for the system. This button is for administrative purposes only. Do not attempt to set the Subnet Mask. 5. Click the Multicast TTL button to open a keypad that allows you to set a valid Mulitcast Time to Live (TTL) for the selected Access Point. Valid values are between 1 and 255. Set the Multicast TTL to 1 unless instructed to do otherwise. This button is for administrative purposes only. Do not attempt to set the Multicast TTL. 6. Click the Prev button to return to the Access Point Configuration screen (page 108). 7. Click the Exit button to close the Access Point Configuration screen and return to the Access Point Settings screen. 110 PatientNet Administrator’s Guide, v1.04, 10001003-004, Revision B All information contained herein is subject to the rights and restrictions on the title page. WMTS OPENNET LAN PROGRAMMING AND DIAGNOSTICS Configuring RF Modules You can view the current RF Module configurations for each Access Point on the network with the RF Module Settings screen. To view RF Module settings: 1. Access the OpenNet LAN screen (page 101). 2. Click the RF Module button to open the RF Module Settings screen (fig. 66), or you can click the Mod Config button on the Access Point Configuration screen (see “Configuring Access Point Parameters” on page 108). Fig. 66. RF Module Settings 3. Click the Status button to open the RF Module Status screen (see fig. 67 on page 112), which allows you to view the current status of each RF Module in the blackboard. 4. Click the Remove button to remove a selected RF Module from the RF Module Settings screen and the OpenNet LAN. • A warning popup will display requesting you to click either Yes, which will remove the selected RF Module, or No, which will close the popup and leave the RF Module unchanged. 5. Click the Exit button to close the RF Module Settings screen and return to the OpenNet LAN screen. PatientNet Administrator’s Guide, v1.04, 10001003-004, Revision B 111 All information contained herein is subject to the rights and restrictions on the title page. WMTS OPENNET LAN PROGRAMMING AND DIAGNOSTICS Viewing RF Module Status Clicking the Settings and Status buttons will allow you to toggle between the RF Module Settings and RF Module Status screens. The RF Module Status screen allows you to view the current status of each RF Module on the RF Module Settings blackboard. To view the status of each RF Module: 1. Access the RF Module Settings screen (see “Configuring RF Modules” on page 111). 2. Click the Status button on the RF Module Settings screen to open the RF Module Status screen (fig. 67). Fig. 67. RF Module Status Screen 3. Click the Settings button to return to the RF Module Settings screen. 4. Use the Pg Up, Pg Dn, and arrow buttons to select a RF Module to configure. 5. Once you have highlighted (selected) a RF Module, click the Select button to open the RF Module Configuration screen (see “Configuring RF Module Parameters” on page 113). The blackboard reflects the current RF Module configurations. 6. Click the Remove button to remove a selected RF Module from the RF Module Settings screen and the OpenNet LAN. • A warning popup will display requesting you to click either Yes, which will remove the selected RF Module, or No, which will close the popup and leave the RF Module unchanged. 7. Click the Reset button to return the status blackboard values to zero. 8. Click the Exit button to close the RF Module Status screen and return to the OpenNet LAN screen. 112 PatientNet Administrator’s Guide, v1.04, 10001003-004, Revision B All information contained herein is subject to the rights and restrictions on the title page. WMTS OPENNET LAN PROGRAMMING AND DIAGNOSTICS Configuring RF Module Parameters You can configure the parameters for each RF Module on each Access Point that is on the OpenNet Network with the RF Module Configuration screen. To configure RF Module parameters: 1. Access the OpenNet LAN screen (page 101). 2. Access the RF Module Settings screen (page 111), highlight the RF Module that you would like to configure, and click the Select button on the RF Module Status screen to open the RF Module Configuration screen (fig. 68). • From the Access Point Configuration screen (page 108), click the Mod Config button to access the RF Module Configuration screen (fig. 68). Fig. 68. RF Module Configuration Screen 3. Select the desired Access Point number by clicking the up and down arrows, which will cycle through the available Access Points and update the fields with the settings for each Access Point. 4. Click the Module ID button to open a keypad that allows you to set the RF Module’s 24 bit identification number. 5. Click the Hop Table button to define the hop table for the RF Module. The available values are 0 to 31. 6. Click Antenna 1 button to cycle through the available antenna types for the first RF Module. The available antennas consist of the following: • Omni (always select Omni) • Patch (future release) • Peanut (future release) PatientNet Administrator’s Guide, v1.04, 10001003-004, Revision B 113 All information contained herein is subject to the rights and restrictions on the title page. WMTS OPENNET LAN PROGRAMMING AND DIAGNOSTICS 7. Click Antenna 2 button to cycle through the available antenna types for the RF Module. The available antennas consist of the following: • Omni (always select) • Patch (future release) • Peanut (future release) 8. Click the Diversity button to define the diversity setting for both antenna 1 and 2. The available settings consist of the following: a. Antenna 1 Auto Ant A1 Ant A2 b. Antenna 2 Auto Ant B1 Ant B2 Note: Select Auto unless instructed to do otherwise. 9. Click the Network Key button to open a keypad that allows you to set the network key for the RF Module. The Network key values can be set from 0 to 255. WARNING: All Access Points must be programmed to the same Network Key as the transceivers. This is an administrative procedure only. Do not attempt to program the Access Points with the Network Key. Note: The Network key can be configured for each module slot. 10. Click the Load Defaults button to return the RF Module parameters to their default values. 11. Click the Neighbors button to open the RF Module Neighbors Configuration screen (see “Configuring RF Module Neighbors” on page 115). 12. Click the Exit button to close the RF Module Configuration screen and return to the RF Module Status screen. 114 PatientNet Administrator’s Guide, v1.04, 10001003-004, Revision B All information contained herein is subject to the rights and restrictions on the title page. WMTS OPENNET LAN PROGRAMMING AND DIAGNOSTICS Configuring RF Module Neighbors You can configure up to eight neighbors for each RF Module in each configured Access Point on the OpenNet LAN. To configure the neighbors of a RF Module: 1. Access the RF Module Configuration screen (page 113). 2. Click the Neighbors button on the RF Module Configuration screen to open the RF Module Neighbors Configuration screen (fig. 69). Fig. 69. RF Module Neighbors Configuration Screen 3. To assign a neighbor to the currently selected Access Point, type in the number of the Neighbor Access Point with the displayed keypad. The Neighbor Access Point number will then appear in the blackboard under the Access Point column. 4. Use the up and down arrows to highlight and select the Access Point Neighbor that you would like to configure. 5. Click the Neighbor Slot button to define the desired slot, either 1 or 2, of the selected access point’s neighbor. • Only Access Point slots that have already been configured on the OpenNet LAN can be selected as a Neighbor slot. Only Neighbor Slot 1 is currently available. 6. Click the up and down arrows under the Configure Access Point heading to define which Access Point is currently selected. • Only Access Point that have already been configured on the OpenNet LAN can be selected. 7. Click the AP Slot button to select the desired slot of the selected Access Point. Only AP Slot 1 is currently available. 8. Click the Exit button to close the RF Module Neighbors Configuration screen and return to the RF Module Configuration screen. PatientNet Administrator’s Guide, v1.04, 10001003-004, Revision B 115 All information contained herein is subject to the rights and restrictions on the title page. WMTS OPENNET LAN PROGRAMMING AND DIAGNOSTICS Viewing OpenNet LAN Diagnostics You can view, and configure, the OpenNet LAN Diagnostics on the OpenNet Diagnostics screen. To View the OpenNet LAN Diagnostics: 1. Click the Diagnostics button on the OpenNet LAN screen to open the OpenNet Diagnostics screen (fig. 70). Fig. 70. OpenNet Diagnostics Screen 2. Click the Set Log Lvl button to toggle through the valid Set Log Level settings. The set level defines the logging event criteria for the OpenNet LAN diagnostic network for a Central Station. The options are None, Fatal, Error, Warning, Info, and Debug. WARNING: This button is for administrative purposes only. Do not attempt to set the Log Level. Note: This feature is only available for the Admin Administration level. 3. Click the Buf Stats button to check the buffer status by outputting the buffer status to the mlog utility. This button is for administrative purposes only. Note: The Set Log Lvl field must be set to a value other than None in order for the status to be sent. 4. Click the Buf Integ button to check the buffer integrity by outputting the buffer status to the mlog utility. The setting will output the data if the buffer integrity is questionable. This button is for administrative purposes only. Note: 116 The Set Log Lvl field must be set to a value other than None in order for the status to be sent. PatientNet Administrator’s Guide, v1.04, 10001003-004, Revision B All information contained herein is subject to the rights and restrictions on the title page. WMTS OPENNET LAN PROGRAMMING AND DIAGNOSTICS 5. Clicking the VTXP Diag button will open the VTXP Diagnostics screen (fig. 71). Fig. 71. VTXP Diagnostics Screen The columns in the VTXP Diagnostics screen are described below. Ch channel number the number of good VTXP packets that have been received for each channel the number of good VTXP packets that have been transmitted to each TX channel Buffer Last displays the number of bytes that were contained in the last good received VTXP packet for each channel Buffer Avg displays the running average for the received buffer for each channel RX Errors CRC displays the number of VTXP CRC errors detected for each channel Errors FRM displays the number of VTXP frame errors detected for each channel SEQ displays the number of VTXP sequence errors detected for each channel O/R displays the number of over run errors detected for each channel U/R displays the number of under run errors detected for each channel Reset the Reset button will return each statistical value to zero Exit the Exit button returns you to the OpenNet Diagnostics screen PatientNet Administrator’s Guide, v1.04, 10001003-004, Revision B 117 All information contained herein is subject to the rights and restrictions on the title page. WMTS OPENNET LAN PROGRAMMING AND DIAGNOSTICS 6. Clicking the VRTP Diag button will open the VRTP Diagnostics screen for each Central Station (fig. 72). Fig. 72. VRTP Diagnostics Screen The columns in the VRTP Diagnostic screen are described below. Ch channel number RX the number of VRTP packets that have been received for each channel CRC displays the number of VRTP CRC errors detected for each channel FRM displays the number of VRTP frame errors detected for each channel SEQ displays the number of VRTP sequence errors detected for each channel ReXmit Reset displays the number of VRTP re-transmissions that were detected for each channel the Reset button will return each statistical value to zero Exit the Exit button returns you to the OpenNet Diagnostics screen 7. Clicking the AP Diag button will open the Access Point Diagnostic screen for each Central Station (fig. 73). 118 PatientNet Administrator’s Guide, v1.04, 10001003-004, Revision B All information contained herein is subject to the rights and restrictions on the title page. WMTS OPENNET LAN PROGRAMMING AND DIAGNOSTICS Fig. 73. AP Diagnostics Screen The columns on the left side of the AP Diagnostic blackboard screen are described below. displays the Access Point number in the Device Master database that is associated with the data IP Address displays the IP address for a given Access Point Num AP Act displays the Access Point active state: Y = Yes, N = No AP Sync AP Ver displays the Access Point sync state: Y = Yes, N = No sync detected • a dash (-) is displayed when an AP is not active. displays the firmware version for each Access Point RFA Ver displays the RF Module A firmware for each Access Point displays the RF Module B firmware for each Access Point (this function will be available in future software release) displays the number of transceivers that are currently attached to the Xmts Access Point Blackboard displays the transceiver IDs for all transceivers attached to each Access Point. Use the up and down arrows to navigate through the listed IDs RFB Ver The buttons in the AP Diagnostic screen are described below. Refresh Clear AP Error Reset Exit this button will refresh all Access Point active and sync status values with the current values that are received from each Access Point this button will clear the currently active VRTP Protocol error this button clears the blackboard, requests all Access Points to identify themselves, updates their status, and displays the received status information on the blackboard • Allow at least 1 minute for large systems reset the Exit button returns you to the OpenNet Diagnostics screen 8. Click the Exit button to close the OpenNet Diagnostics screen and return to the OpenNet LAN screen. PatientNet Administrator’s Guide, v1.04, 10001003-004, Revision B 119 All information contained herein is subject to the rights and restrictions on the title page. WMTS OPENNET LAN PROGRAMMING AND DIAGNOSTICS Configuring the OpenNet System You can configure the OpenNet LAN parameters that are specific to each WMTS Central Station with the OpenNet System Configuration screen. To configure the OpenNet system: 1. Click the System button on the OpenNet LAN screen to open the OpenNet System Configuration screen (fig. 74). Fig. 74. OpenNet System Configuration Screen 2. Click the IP Address button to open a keypad with which you enter the OpenNet LAN IP address for the system. 3. Click the Subnet Mask button to open a keypad with which you can enter the OpenNet LAN subnet mask for the system. 4. The Default Gateway button will be available in future releases. 5. The Multicast TTL button will be available in future releases. 6. Click the Set AP Defaults button to open the Access Point Default Configuration screen (see “Configuring Access Point Defaults” on page 121). 7. Click the Exit button to close the OpenNet System Configuration screen and return to the OpenNet LAN screen. 120 PatientNet Administrator’s Guide, v1.04, 10001003-004, Revision B All information contained herein is subject to the rights and restrictions on the title page. WMTS OPENNET LAN PROGRAMMING AND DIAGNOSTICS Configuring Access Point Defaults You can configure the default settings for all Access Points in the Access Point Default Configuration screen. To configure Access Point defaults: 1. Access the OpenNet System Configuration screen (page 120). 2. Click the Set AP Defaults button to open the Access Point Default Configuration screen (fig. 75). Fig. 75. Access Point Default Configuration Screen 3. Click the RF Modules button to toggle the RF Module setting between 1 and 2. The RF Module setting defines the default number of RF Modules that reside in each Access Point. 4. Click the IP Address button to open a keypad with which you can set the default IP address for the Access Points. 5. Click the Location button to open the Location popup (see fig. 76 on page 121), which allows you to enter the default location of the Access Points. Fig. 76. Access Point Default Location Popup 6. Click the Exit button to close the Access Point Default Configuration screen and return to the OpenNet System Configuration screen. PatientNet Administrator’s Guide, v1.04, 10001003-004, Revision B 121 All information contained herein is subject to the rights and restrictions on the title page. WMTS OPENNET LAN PROGRAMMING AND DIAGNOSTICS Programming Transceivers You can program DT-4500 and DT-7000/7001 transceivers with a programming cable connected to the I/O board of any Central Station unit. Required Items • 9 V Battery for DT-4500 • Power Supply for DT-7000/DT-7001 transceiver • Programming cable for DT-4500 or DT-7000/7001 Transceivers • DT-4500 or DT-7000/DT-7001 transceivers Attaching Transceiver Programming Cables For the DT-4500 1. Attach the programming cable to the Port 2 connector on the MSIO board on the rear of the unit. 2. Remove the battery from the DT-4500 transceiver. 3. Remove and save the port plug, if in place. Connect the other end of the programming cable to the connector on the DT-4500 transceiver. 4. Place the 9 V battery into the transceiver, with the power contacts facing down into the transceiver. For the DT-7000 1. Attach the programming cable to the Port 3 connector on the MSIO board on the rear of the unit. 2. Connect the other end of the programming cable to Port 1 on the DT-7000/DT-7001 transceiver. 3. Connect the DT-7000/DT-7001 power supply to the DT-7000/DT-7001 Power Connector and to the 120 VAC/60 Hz wall power. Note: 122 The Port numbers listed above are the default ports. If you change the programming port parameter in the software, then you must also connect the programming cable to the appropriate MSIO port based on the selection. PatientNet Administrator’s Guide, v1.04, 10001003-004, Revision B All information contained herein is subject to the rights and restrictions on the title page. WMTS OPENNET LAN PROGRAMMING AND DIAGNOSTICS Programming Ambulatory Transceivers (DT-4500) To program the DT-4500: 1. Access the OpenNet LAN screen (page 101). 2. Click the Program AT button to open the Ambulatory Transceiver Programming screen (fig. 77). Fig. 77. Ambulatory Transceiver Programming screen 3. If the “No response from transceiver” popup appears, check the programming cable connections and the transceiver battery. To re-attempt, wait until the I/O LED on the DT-4500 stops flashing, and then select the Read TX button. 4. Click the Tx Info button to open the Transceiver Information popup (fig. 78), which displays the current information for the attached transceiver. Click OK to close the popup Fig. 78. Transceiver Information popup 5. Click the Read TX button to read the currently programmed information located on the transceiver and update the fields on the Program Transceiver screen. PatientNet Administrator’s Guide, v1.04, 10001003-004, Revision B 123 All information contained herein is subject to the rights and restrictions on the title page. WMTS OPENNET LAN PROGRAMMING AND DIAGNOSTICS 6. Toggle ECG Filter (frequency response) to 0.5 or 0.05 MHz. This determines how fast the ECG lead is adjusted after baseline changes. WARNING: Program the DT-4500 transceiver to 0.05 Hz if you are performing ST analysis. Otherwise, unpredictable and inaccurate analysis will result. You may use 0.5 Hz if you are not using ST analysis. 7. Click the Program Port button to select the MSIO port that will be used for the transceiver programming interface. Clicking the button will cycle through following options: • MSIO 1 • MSIO 2 (DT-4500 default) • MSIO 3 • MSIO 4 • None Note: The Program Port field will only display the ports that are currently available for the system. Thus, if all four ports are selected, and you decide to change ports, none of the ports are available. You must select None on one port in order to make it available (as the ports are mutually exclusive), and then assign the available port to another device. Selecting None prevents Port lockout. 8. Click the Device ID button to open a keypad that allows you to set the transceiver’s device identification number (0 - 1000). 9. Click the Network Key button to open a keypad that allows you to set the transceiver’s network number (0 - 255). WARNING: All transceivers must be programmed to the same Network Key as the Access Points. This is an administrative procedure only. Do not attempt to program the transceivers with the Network Key. 10. Click the LL Threshold button to open a keypad that allows you to set the transceiver’s Loose Lead Threshold value (100-200). Electrode impedance values below this threshold trigger a Lead Off alarm for all leads dependent on the electrode violation. 150 is the default value. 11. Click the QL Threshold button to open a keypad that allows you to set the transceiver’s Quality Lead Threshold value (100 - 200). This parameter defines whether an electrode’s LED on the DT-4500 will illuminate when the Attendant Present buttons are pressed. 156 is the default value. 124 PatientNet Administrator’s Guide, v1.04, 10001003-004, Revision B All information contained herein is subject to the rights and restrictions on the title page. WMTS OPENNET LAN PROGRAMMING AND DIAGNOSTICS Transceiver Impedance Values The DT-4500 Ambulatory Transceivers electrode impedance values, which are displayed on the OpenNet Transceiver Status screen (see fig. 86 on page 136), indicate the quality of the signal connection and are not the actual impedance values that are measured by the system. The electrode impedance values range from 100 to 200 (optimal). The typical values range between 180 and 200. If the electrode’s impedance value is greater than the defined Quality Threshold value, then its LED is illuminated. The DT-4500 stores the Quality Threshold value and uses this value to determine whether or not the electrode LED should be illuminated when the Attendant Present buttons are pressed. See the PatientNet Operator’s Manual for details on the DT-4500 Buttons and LED indicators. Note: A Lead Off alarm will occur when an electrode’s impedance value drops to, or below, the current Loose Lead Threshold value. 12. Click the PA SILENCE button to enable or disable the Procedure Alarm Silence function for the transceiver. See the PatientNet Operator’s Manual for details on the Procedure Alarm Silence function. 13. Click the Program TX button to program a transceiver with the new parameters and read the programmed information back for validation. The transceiver is now programmed. Note: The attached device (AT or IT) is only programmed with the new parameters when the Program TX button is pressed. Simply changing a parameter’s value does not program the device. Programming is a two-step process: (1) modify the desired parameter(s); (2) press the Program TX button. Note: An error message that reads “Programming failure” is displayed when the parameters read back from the transceiver differ from the parameters that were written to the transceiver. 14. Click the F/W Download button to display the Advanced Program Transceiver Firmware Download screen (see fig. 79 on page 126). 15. Click the Advanced RF button to display the Advanced Program Transceiver RF Module screen (see fig. 80 on page 127). 16. Click the Exit button to close the Ambulatory Transceiver Programming screen and return to the OpenNet LAN screen. PatientNet Administrator’s Guide, v1.04, 10001003-004, Revision B 125 All information contained herein is subject to the rights and restrictions on the title page. WMTS OPENNET LAN PROGRAMMING AND DIAGNOSTICS Downloading Ambulatory Transceiver (DT-4500) Firmware You can download firmware modules for the DT-4500 and RF Module through the Firmware Download Advanced Program Transceiver screen. To download transceiver firmware: 1. Access the OpenNet LAN screen (page 101). 2. Access the Ambulatory Transceiver Program screen (page 123). 3. Click the F/W Download button to display the Advanced Program Transceiver Firmware Download screen (fig. 79). Fig. 79. Firmware Download Advanced Program Transceiver Screen, AT Note: If no Firmware Download Modules appear in the blackboard, then call your technical support representative to order the appropriate Download Firmware Module Disk. 4. Use the up and down arrows to view the available transceiver firmware download modules in the Download File Description field. Select the appropriate download module for the transceiver type. 5. Click the Download Ambulatory Tx Firmware button to download the DT4500 firmware. The DT-4500 battery voltage is checked and verified prior to downloading. • If the voltage check fails, then the transceiver programming is aborted. • If ample voltage is available, then the DT-4500 is powered off and the downloading popup appears. Click Continue to proceed with downloading the new firmware. Click Cancel to abort the download and the transceiver’s firmware is not modified. 6. Click the Download RF Module Firmware button to download the RF Module’s firmware. Click Continue or Cancel when the downloading popup appears. • Select Continue to proceed with downloading the new RF Module firmware. • Click Cancel to abort the download and the firmware is not modified. 7. Click the Exit button to return to the Ambulatory Transceiver Programming screen. 126 PatientNet Administrator’s Guide, v1.04, 10001003-004, Revision B All information contained herein is subject to the rights and restrictions on the title page. WMTS OPENNET LAN PROGRAMMING AND DIAGNOSTICS Programming RF Modules for Ambulatory Transceivers You can program the RF Modules of Ambulatory Transceivers (AT), DT-4500s, with the RF Module Advanced Program Transceiver screen. To program AT RF Modules: 1. Access the OpenNet LAN screen (page 101). 2. Access the Ambulatory Transceiver Program screen (page 123). 3. Click the Advanced RF button to display the RF Module Advanced Program Transceiver screen (fig. 80). Fig. 80. RF Module Advanced Programming screen, AT 4. Click the Read TX button to read the currently programmed information located on the transceiver and update the fields. 5. Click the Pkt Attempt Limit button to open a keypad that allows you to set the number of packet attempts limit for the selected RF module. The available settings are between 0 and 22. 6. Click the Diversity button to toggle between Ant A, Ant B, or Auto, which sets the transceiver’s diversity setting. 7. Click the Roaming button to toggle between Enabled and Disabled, which sets the transceiver’s roaming capabilities. 8. Click the Roam Threshold button to open a keypad that allows you to enter the transceiver’s roam threshold value. The available settings are between 0 and 255. 9. Click the Channel Mute button to set the transceiver’s Channel Mute frequency. 32 frequencies are available based on the RF Modules hardware. PatientNet Administrator’s Guide, v1.04, 10001003-004, Revision B 127 All information contained herein is subject to the rights and restrictions on the title page. WMTS OPENNET LAN PROGRAMMING AND DIAGNOSTICS 10. Click the OP Band button to set the operating band that will be used by the RF Module. • Typically, the 608.5-613.0 OP Band is selected. However, where the PatientNet System operates in the same hospital as another system (or systems) that also use(s) the 608-614 MHz WMTS band, it will be necessary to select one of the sub-bands. The sub-band should coordinate with the hospital’s spectrum policy. • Additional sub-bands include: 608.5-609.7, 609.6-610.8, 610.7-611.9, and 611.8-613.0 WARNING: All transceivers must be programmed to the same OP Band as the Access Points. This is an administrative procedure only. Do not attempt to program the transceivers with the selected OP Band. 11. Click the Program TX button to program a transceiver and read the programmed information back for validation. The transceiver is now programmed. 12. Click the Exit button to return to the Ambulatory Transceiver Programming screen. 128 PatientNet Administrator’s Guide, v1.04, 10001003-004, Revision B All information contained herein is subject to the rights and restrictions on the title page.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.3 Linearized : No Create Date : 2002:11:26 14:07:28 Producer : Acrobat Distiller 4.05 for Windows Creator : AdobePS5.dll Version 5.1.1 Title : 06-10001003-004_B.fm Modify Date : 2002:11:26 14:07:28-08:00 Page Count : 28EXIF Metadata provided by EXIF.tools