Pegaso™
Industrial PDA
with Windows® CE
Falcon/Pegaso P40-2001
Pegaso
Pegaso in Dock
Quick Reference Guide
Datalogic Mobile, Inc
1505 Westec Dr.
Eugene, Oregon 97402
Telephone: (541) 743-4800
Fax: (541) 743-4900
An Unpublished Work - All rights reserved. No part of the contents of this documentation or the procedures
described therein may be reproduced or transmitted in any form or by any means without prior written permission of Datalogic Mobile, Inc. or its affiliates or subsidiaries ("Datalogic" or “Datalogic Mobile”) . Owners
of Datalogic products are hereby granted a non-exclusive, revocable license to reproduce and transmit this
documentation for the purchaser's own internal business purposes. Purchaser shall not remove or alter
any proprietary notices, including copyright notices, contained in this documentation and shall ensure that
all notices appear on any reproductions of the documentation.
Should future revisions of this manual be published, you can acquire printed versions by contacting your
Datalogic representative. Electronic versions may either be downloadable from the Datalogic Mobile website (www.mobile.datalogic.com) or provided on appropriate media. If you visit our website and would
like to make comments or suggestions about this or other Datalogic publications, please let us know via the
“Contact Datalogic” page.
Disclaimer
Datalogic has taken reasonable measures to provide information in this manual that is complete and accurate, however, Datalogic reserves the right to change any specification at any time without prior notice.
Datalogic is a registered trademark of Datalogic S.p.A. and the Datalogic logo is a trademark of Datalogic
S.p.A. all licensed to Datalogic Mobile, Inc. All other trademarks and trade names referred to herein are
property of their respective owners.
Falcon® is a registered trademark of Datalogic Mobile, Inc. and of its wholly owned subsidiaries.
Microsoft Windows®, Windows® 2000, Windows® CE, Windows® NT, and Windows® XP are registered
trademarks of Microsoft Corporation.
Patents
This product may be covered by one or more of the following patents:
4,861,972 • 4,866,257 • 4,879,456 • 5,198,649 • 5,208,449 • 5,212,372 • 5,247,161 • 5,311,000 • 5,440,110 • 5,481,098 •
5,493,108 • 5,508,505 • 5,664,231 • 5,671,374 • 5,686,716 • 6,041,374 • 6,412,698 • 6,415,978 • 6,454,168 • 6,478,224 •
6,513,714 • 6,536,670 • 6,561,427 • 6,585,157 • 6,923,377 • 7,108,170 • D377345 • CA2,188,399 • Other U.S. and Foreign
Patents Pending.
Table of Contents
Pegaso™ Industrial PDA with Windows® CE ................................ 3
Overview ............................................................................................ 3
Features ....................................................................................... 3
Getting Started ................................................................................... 5
Powering the Pegaso ............................................................................ 5
Battery Pack ................................................................................. 5
Installing the Battery Pack .............................................................. 6
Battery Power .................................................................................... 7
System Tray Battery Status Indicators ............................................. 7
Charging the Batteries ................................................................... 8
Charging with the Dock .................................................................. 9
Charging with a Battery Charger .................................................... 10
Backup Battery ........................................................................... 11
Setting Up the Mobile Computer .......................................................... 11
Touchscreen Calibration ............................................................... 11
Getting Connected ....................................................................... 11
Setting the Date and Time ............................................................ 13
Using the Stylus .......................................................................... 13
Ambient Light Sensor ................................................................... 14
Navigating the Display ....................................................................... 14
Keypad ............................................................................................ 17
Scanning Bar Codes ........................................................................... 20
Laser Scanning ........................................................................... 20
Persistent Memory ............................................................................. 22
Context Sensitive Help ....................................................................... 22
Resetting the Pegaso .......................................................................... 22
Warm Reset ................................................................................ 23
Cold Reset .................................................................................. 24
Maintaining the Pegaso ....................................................................... 25
Troubleshooting ................................................................................ 25
RF Connectivity Troubleshooting .................................................... 28
Technical Support .............................................................................. 29
Datalogic Mobile Website Support .................................................. 29
Datalogic Mobile Website TekForum ............................................... 29
Reseller Technical Support ............................................................ 29
Telephone Technical Support ......................................................... 29
Resources ......................................................................................... 29
Appendix A: Datalogic Mobile Pegaso™ Windows® CE
End User License Agreement ..................................................... 31
Appendix B: Microsoft® Windows® CE
End User License Agreement ..................................................... 36
Quick Reference Guide
Appendix C: Datalogic Mobile Pegaso Windows® CE
Product Warranty.......................................................................38
Appendix D. Safety and Regulatory Information .........................40
Laser Safety Label .............................................................................. 40
Advisory Statement ...................................................................... 40
Regulatory Statements ....................................................................... 40
Industry Canada statement: .......................................................... 42
Appendix E: Laser Safety ...........................................................43
English ....................................................................................... 43
French ........................................................................................ 43
German ...................................................................................... 44
Italian ........................................................................................ 44
Danish ........................................................................................ 45
Dutch ......................................................................................... 45
Swedish ...................................................................................... 46
Finnish ....................................................................................... 46
Norwegian .................................................................................. 47
Portuguese .................................................................................. 47
Spanish ...................................................................................... 48
Chinese ...................................................................................... 49
Japanese .................................................................................... 50
Pegaso™ Industrial PDA with Windows® CE
Pegaso™
Industrial PDA
with Windows® CE
Overview
The Datalogic™ Pegaso industrial PDA combines the flexibility of Windows®
CE with the power of the Intel XScale processor, WiFi wireless technology, a
large color display, and laser scanning in an ergonomic PDA. The Pegaso is a
rugged device suitable for both Commercial and Industrial environments, as
well as Retail-in-Store inventory management applications (back room inventory management and shipping/receiving, shelf inventory management, price
lookup, and relabeling applications). The Pegaso will handle 5’ / 1.5M drops to
concrete, and has an IP64 environmental rating.
The Falcon Management Utility (FMU) and Falcon Desktop Utility (FDU) are
included with every unit, providing remote management and configurability.
Features
•
•
•
•
•
•
•
•
End user configurable keypad with custom overlay available
Best in class Full VGA 3.6” Display for indoor and outdoor use
Ergonomic design
2200 mAHr battery or 3300 mAh extended battery
Bluetooth direct to Host PC (no dock necessary), 802.11b/g available
User accessible SDIO slot on top
No tools required for attachables & expansion
High power output (500mA) on base connector, allows multiple attachables or tethered/powered scanners
• Single piece quick-replace battery/cover
• 64 or 128 MB RAM, 128 MB Flash
Quick Reference Guide
Overview
Figure 1. Pegaso Front & Rear Views
LED Scanning/
Charging Indicators
Speaker
Power Key
Belt Clip
Handstrap
Stylus
Touchscreen
Display
Battery Pack
Handle (Optional)
Keypad
SD Door
Top View
Scan
Triggers
Scanner Aperture
Antenna
(GPRS only)
2.5 mm
Headset Jack
USB/Serial Connector
For a complete description of each key on the Pegaso, refer to page 17 in this
manual. Also refer to the Pegaso Windows® CE Product Reference Guide (PRG),
available on the Pegaso Product CD that came with your device, or from the
Datalogic Mobile web site at www.mobile.datalogic.com.
Pegaso™ Industrial PDA with Windows® CE
Getting Started
Getting Started
Before using the Pegaso for the first time, you must install the Battery Pack into
the unit, then charge both the Battery Pack and the Backup Battery. See Installing the Battery Pack on page 6 for instructions.
CAUTION
You must charge the battery pack and backup battery in a dock or
with a power cable prior to your first use of the Pegaso. The initial
charge time is approximately 4 hours. See Charging the Batteries on
page 8 for more information.
Powering the Pegaso
Battery Pack
The battery pack in the Pegaso is a 3.7 V, 2200
mAh or 3300 mAh Lithium Ion battery pack. A
message dialog box will appear when the battery
pack reaches a low state.
After charging the first time, a complete charge
takes about four (4) hours depending on the battery pack’s state and the recharging method. A
sample battery pack label is shown at right. The
label on your unit may vary from the illustration.
®
US
LISTED
NWGQ7 2Z78
Li-Ion 3.7V 2200mAh (High Capacity 3300mAh)
CAUTION: Do not short circuit, disassemble,
incinerate or mutilate pack.
Datalogic Mobile, Inc
Made in China
P/N: xxxx-xxxx (High Capacity P/N: xxxx-xxxx)
S/N: xxxxxx
You must charge the battery pack and backup battery in a dock or
with a power cable prior to your first use of the Pegaso. The initial
charge time is approximately 4 hours.
If you remove the battery pack or it fails, there is a 30-minute window
CAUTION in which to insert a charged battery pack before the backup battery
fails. If your backup battery fails, the contents of the RAM memory
will be lost. If your back-up battery is less than fully charged, there is
a smaller window of time available. Usage time will be reduced, also.
Always charge within temperature range of 32°–113°F (0°–40°C).
Use only the authorized power supplies, battery packs, chargers, and
docks supplied by your Datalogic reseller. The use of other power
supplies can damage the unit and void your warranty. Refer to the
PRG for the correct power supplies and Accessories.
Quick Reference Guide
Powering the Pegaso
Lithium-ion battery packs may get hot, explode, ignite, or/and cause
serious injury if exposed to abusive conditions.
•
Do not place the battery in or near fire, direct sunlight, or other
high temperature locations, or heat the battery.
•
Do not connect the positive terminal and negative terminal of the
WARNING
battery to each other with any metal object (such as wire or coin).
•
Do not expose the battery to liquids, or allow to get wet.
•
Do not disassemble, modify, or pierce the battery. The battery contains safety and protection devices, which, if damaged, may cause
the battery to generate heat, explode or ignite.
In the event the battery leaks and the fluid gets into your eye, do not
rub the eye. Rinse well with water and immediately seek medical care.
If left untreated, the battery fluid could cause damage to the eye.
Datalogic recommends annual replacement of rechargeable battery
packs to ensure maximum performance.
Installing the Battery Pack
When you first remove the Pegaso from the box, you must charge
both the battery pack and the backup battery for a minimum of 4
hours.
The Pegaso’s Battery and its cover are integrated — they do not come apart.
Complete the following instructions to install the battery pack:
1.
Loosen the elastic handstrap by releasing it from the bottom of the unit
(refer to the PRG).
2.
Orient the battery pack with the latch facing toward the top of the Pegaso
(refer to Figure 2 on page 7).
3.
Replace the battery door by inserting the bottom tab into the unit, then
clicking the latch into place. If the battery pack is installed incorrectly, it
will not seat properly.
4.
Replace the handstrap at the bottom of the unit.
Pegaso™ Industrial PDA with Windows® CE
Battery Power
Figure 2. Installing the Battery Pack
Battery Pack
Battery Latch
(push in to release)
Seat this
end first
Battery Power
If you remove the battery pack or the battery fails, you have about 30
minutes to swap in a new battery pack or charge the battery pack
before the backup battery fails (if the backup battery has been fully
charged).
System Tray Battery Status Indicators
The System Tray displays icons to show the status of some battery conditions,
as shown in Table 1.
Table 1. System Tray Battery Status Indicators
Battery Status Icons
Battery
Status
Icon
Backup
Battery Low
Condition
no icon
Description
The battery status is updated in the control panel, but no icon is
displayed.
Backup
Battery Very
Low
Condition
When the backup battery is very low, the system tray contains a
very low backup battery CAUTION icon. In addition, a dialog box
pops up and alerts you that the backup battery is very low and
needs to be charged. The dialog comes up every five minutes until
you charge the backup battery.
Battery
Charging
Condition
This icon indicates that the battery pack is currently charging.
Quick Reference Guide
Battery Power
Battery Status Icons
Battery
Status
Icon
Description
Battery Low
Condition
This icon indicates that the battery pack is low.
Battery Very
Low
Condition
When the battery pack is very low, the system tray shows a very
low battery CAUTION icon. Also, a dialog box pops up and alerts
you to charge the battery pack. A battery warning dialog will pop up
every five minutes until you charge the battery.
Battery
Power
Gauge
Discharged
Battery
Condition
Main batteries
Remaining power:
no icon
100
The Power control applet displays a battery
power gauge.
Start > Settings > Control Panel > Power.
When the battery is totally discharged, the battery sensor initiates a
shutdown of all applications, and closes the RF Network connection. If the battery pack has completely discharged, when the battery pack is charged or replaced, the unit will resume as before
after a cold reset.
Refer to Persistent Memory on page 22 regarding the data loss of
applications and data stored in RAM.
Charging the Batteries
There are several methods for charging the battery pack and backup battery.
LEDs on the Pegaso, the Single-Slot Dock, and the Four-Slot Battery Charger
give visual indication of the charge state. Table 2 on page 8 gives an overview of
all the LEDs and what they indicate.
Table 2. Battery Charging Methods and Indications
Charging
Location:
Charging
Duration
Pegaso
Pegaso connected
seated in a
to an external
Dock (Single
power supply
or Four-Slot)
4-6 hours
4-6 hours
Charging slot of
Dock (Single or
Four-Slot)
Pegaso
Four-Slot
Battery
Charger
3-5 hours
> 3 hours
Pegaso™ Industrial PDA with Windows® CE
Battery Power
Charging
Location:
Battery Pack
Charge
Indication:
Pegaso Charge
LED
Pegaso
Pegaso connected
seated in a
to an external
Dock (Single
power supply
or Four-Slot)
Charging:
RED
Fully
Charged:
GREEN
Charging slot of
Dock (Single or
Four-Slot)
Pegaso
Four-Slot
Battery
Charger
Charging: RED
Fully Charged:
GREEN
N/A
N/A
Charging:
Charging
LEDs are RED
Fully charged:
Ready LEDs
are GREEN
Error: AMBER
NO
Dock or
Charger
Battery Charge
LED(s)
No effect
No effect
Charging:
Solid RED
Fully charged:
GREEN
*Fault:
Flashing RED
Simultaneously
Charges
Backup Battery
YES
YES
NO
Charging with the Dock
A Single-Slot Dock powered by an external power supply (AC adaptor) is available for the Pegaso. Pegasos communicate with the host PC using Microsoft
ActiveSync protocol via either a USB or serial port.
Two methods exist for charging a battery pack using a Single-Slot Dock. Refer
to Table 2 on page 8. The amber light on the Dock will blink when a battery is
inserted, to indicate a successful connection. For more information on the dock,
refer to the Instructions that come with each dock.
Quick Reference Guide
Battery Power
Figure 3. Charging the Battery Pack in a Dock
Tilt Forward to Remove
USB/Serial Connector
LEDs
Battery Pack in
Charger
Refer to Table 2 on page 8 for a list of LED indicators and their purpose. Refer
to the PRG for more info on storage and disposal of batteries.
Charging with a Battery Charger
The Pegaso is available with a Four-Slot Battery Charger. Use the Battery
Charger to charge batteries independently of the unit.
Figure 4. Four-Slot Battery Charger
LEDs
10
Pegaso™ Industrial PDA with Windows® CE
Setting Up the Mobile Computer
Backup Battery
The rechargeable 3.7V Lithium Backup Battery receives its charge from the Battery Pack. To retain date, time, data, and other settings for the Pegaso, maintain
at least a minimal charge on the Battery Pack.
When the backup battery is low, an icon will display on the status bar (see
Table 1 on page 7), and a dialog box will open to alert you.
Setting Up the Mobile Computer
At first use or cold reset, the unit will go through an initial bootup sequence:
1.
Touchscreen Calibration on page 11.
2.
Getting Connected on page 11.
3.
Network Setup on page 12.
4.
Setting the Date and Time on page 13.
Touchscreen Calibration
Figure 5. Touchscreen Calibration
Follow the on-screen directions to calibrate
the touchscreen.
For more information on touchscreen calibration, refer to the PRG.
Getting Connected
Bluetooth Setup
1.
Open the Bluetooth control panel at Start > Settings > Control Panel >
Bluetooth Device Properties.
2.
Tap Scan Device to search for available Bluetooth Devices.
Quick Reference Guide
11
Setting Up the Mobile Computer
3.
Double tap the listing for the device you want to activate. Specify the
device as Trusted, and authenticate if needed.
4.
Double tap again and select Active to activate the device.
For more detailed instructions, refer to the Pegaso Windows CE PRG.
Connecting to a PC
In order for the Pegaso to communicate with a host PC, Microsoft® ActiveSync
must be installed on the computer. You can install it from the Product CD
included with your unit, or go to www.microsoft.com/downloads/ for information. Reference the Pegaso PRG for detailed instructions.
Network Setup
1.
Select Start > Settings > Network and Dialup Connections.
2.
Double-tap on the item (varies based on the radio installed and the number of connections).
3.
Complete the two tabs (shown in Figure 6):
Figure 6. Modifying Network Connection Settings.
• IP Address: Select DHCP or set static IP settings.
• Name Servers: If using static IP, set DNS and WINS servers.
12
Pegaso™ Industrial PDA with Windows® CE
Setting Up the Mobile Computer
Setting the Date and Time
1.
From the Start menu, select Settings >
Control Panel > Date/Time. Use the arrows to
navigate or change the time or date.
2.
Change the year by backspacing, or entering a new year.
3.
Select the month to open a pull-down list
of months.
4.
Tap the checkbox to Automatically adjust
clock for daylight savings time, if desired.
Using the Stylus
Never use a pen, pencil, or other sharp object on the Pegaso’s
touchscreen display. Use only the supplied stylus or plastictipped pens intended for use with a touch-sensitive display. Contact your reseller to replace a missing stylus.
The stylus is located next to the scanning pod as illustrated in Figure 7. The stylus on the Pegaso is the equivalent of the mouse on a PC. Use the stylus to:
• Navigate the touchscreen display.
• Select characters in the soft input panel (SIP).
• Select applications from the desktop or system tray.
• Select tabs, fields and text within applications and dialog boxes.
Figure 7. Back View of a Pegaso with a Stylus
Stylus Holder
Scanner Aperture
Stylus
Replace the stylus into the holder after each use so you don’t misplace it.
Quick Reference Guide
13
Navigating the Display
Ambient Light Sensor
The ambient light sensor is used by the Pegaso to automatically adjust the intensity of the backlight on the display and keypad in response to changes in lighting conditions. It is located on the keypad. Reference the Pegaso PRG for
information on enabling or disabling this feature.
Screen Protector
A Screen Protector is available for the Pegaso. Reference the Pegaso PRG for
information on installation.
Navigating the Display
There are several navigation areas on your display, including the command bar,
and task bar. Each of these navigation areas have sub-areas of navigation as well.
Take the time to familiarize yourself with these features to save yourself valuable
time.
The Command Bar
Use the Command bar at the top of the screen to perform tasks in programs, such
as opening a file, saving a file, or editing a file. Refer to Figure 8.
14
Pegaso™ Industrial PDA with Windows® CE
Navigating the Display
Figure 8. Application Navigation
Command Bar (Top)
Desktop
Application
Icons
Soft Input
Panel
System Tray
Network Connection
AC Power Indicator
Task Bar (Bottom)
Active Application Window
Start Button
Extras Menu Button (Open Applications)
The Task Bar
The Task bar at the bottom of the screen displays the start menu icon, an icon
for the active program, the current time, and system icons for utilities loaded in
memory, including the keyboard icon, which opens and closes the soft input
panel (SIP).
Start Button — Click the Start button to open the Start menu. The Start menu
includes access to Programs, Favorites, Documents, Settings, Help, and the Run
command. From Settings you can access the Control Panel, Network and Dial-up
Connections, and the Taskbar and Start Menu.
System Tray — The System Tray contains icons for key presses, utilities and
applets running in the background. Click the small arrow(s) in the System Tray
to view icons for current input mode(s), keypress, power management, and network connections.
Extras Menu — Tap Extras Menu at the far right of the Task bar to select from
open applications or to access the desktop while leaving a program open.
Quick Reference Guide
15
Navigating the Display
Soft Keypad/Input Panel
In applications that accept keyed input, the soft input panel (SIP) can be used to
enter data using the stylus. The SIP is a digital, QWERTY-style keyboard.
Figure 9. Soft Input Panel
Keyboard Icons
Soft Input Panel
To open the SIP: — Tap the Keyboard icon to open the menu and select Keyboard from the pop-up menu to open the keyboard.
To close the SIP: — Tap the Keyboard icon to open the menu and select Hide
Input Panel to close the keyboard.
Use the stylus to select letters, numbers, or symbols from the Soft Input Panel for
the current application. Tap the
key to show international letters.
Transcriber
Select Transcriber to provide keyboard input using handwriting and gestures on
the touchscreen. You can use the stylus to write words, numbers or symbols
directly on the screen, and the result will be sent to the current application. A
help screen will appear upon first use.
16
Pegaso™ Industrial PDA with Windows® CE
Keypad
Figure 10. Transcriber
Keypad
The Pegaso is available with a 19-key keypad. Refer to the PRG for information
on configuring the keypad.
Table 3. Keypad Overview - Special Keys
Key Name
Function/Description

Press  to access upper case alpha characters and symbols on the
19-key keypad.
Numeric
Keys
In Normal mode, use the numeric keys to enter numbers. In Alpha mode
these keys can be used to type uppercase letters or punctuation.

Press  to enter the FN input state. Use FN mode to access additional
features and operations.
A customizable keypad overlay will be available for order, allowing you to
remap the Keypad to your specifications.

Press Power to put the Pegaso into sleep (suspend) mode if it is currently
running, and wake up (resume) the unit if it was in sleep mode. Press and
hold it briefly to turn off the unit.

Press  to activate the laser scanner.
Press the edge of the 4-way rocker key to move the cursor or highlighted text
entry during a menu/list selection. In a text window:
4-Way
Rocker
Key
The  arrow moves the cursor up one line.
The  arrow moves the cursor to the right one character.
The  arrow moves the cursor down one line.
The  arrow moves the cursor to the left one character.
 Used to initiate or end Data Connection .
Quick Reference Guide
17
Keypad
System Tray Keyboard Indicators
The System Tray Keyboard Indicators are located at the bottom of the display.
The most recently activated state is to the left if more than one state is active.
Scroll between icons to view the active modes.
Table 4. Input States and their System Tray Indicators
Icon
State
Function
Alpha
Mode
Press  to enter uppercase alpha characters and symbols. When
in Alpha mode, the current alpha character is displayed by a system tray
keyboard indicator.
Alpha mode is persistent, which means that the system stays in Alpha
mode until you press  again.
Fn Mode
Press  to enter FN mode.  is independent of the  key.
Use FN mode to access the features and operations on the keypad.
19-Key Keypad
The Pegaso keypad is organized like a cell phone, with multi-tap access to
uppercase alpha characters on numeric keys (see Figure 11). Use the alphanumeric keys and the  key to type letters, numbers, and symbols listed in
Table 5 on page 19.
Figure 11. Pegaso Keypad
Send/End
Scan
Esc/ Menu
ESC
BkSp/Tab
Fn
Alpha
2 ABC
3 DEF
TAB
4 GHI
5 JKL
6 MNO
FN
7 PQRS
8 TUV
9 WXYZ
AZ
Period/*
4-Way Rocker
Alpha-numeric
keys
Enter/#
0/Space
Key Functions — Most of the keys on the keypad of the Pegaso have more
than one function. To access the secondary features and functions, you must
first press another key to obtain the desired input state.
Numeric Keys — Press the keys in Table 5 once, twice, or more to cycle
through the alpha letters and symbols until the desired character appears in the
system tray. After the last character in the sequence for that key, the next keypress will generate the first letter or symbol in the sequence.
18
Pegaso™ Industrial PDA with Windows® CE
Keypad
Table 5. 19-Key Keypad Alpha Characters and Symbols
Normal
Mode
Key

<1>
<2>
<3>
<4>
<5>
<6>
<7>
<8>
<9>
Alpha Mode
First
Keypress
Second
Keypress
Third
Keypress
Fourth
Keypress
Fifth
Keypress
Table 6. 19-Key Keymap
Normal
Fn
Alpha
Fn + Alpha
F1
F1
F2
abc
F2
F3
def
F3
F4
ghi
F4
F5
jkl
F5
F6
mno
F6
F7
pqrs
F7
F8
tuv
F8
F9
wxyz
F9
F10
Space
F10
Period
Period
F11
F11
Enter
Enter
F12
F12
Quick Reference Guide
19
Scanning Bar Codes
Normal
Fn
Alpha
Fn + Alpha
Bksp
Bksp
Del
Tab
Del
Esc
Esc
Pause
Menu
Pause
Up
Up
PgUp
Up
PgUp
Down
Down
PgDn
Down
PgDn
Left
Left
Home
Left
Home
Right
Right
End
Right
End
Alpha
Alpha
Start
Alpha
Start
The FN+ALPHA state defaults to equivalent operation as the FN state.
Scanning Bar Codes
Laser Scanning
To use the scanning function on units containing a laser scanning module, complete the following steps:
1.
Select and open a data capture application, such as Microsoft® WordPad.
20
Pegaso™ Industrial PDA with Windows® CE
Scanning Bar Codes
Figure 12. Scanning a Bar Code
Press a Scan key or the Scan
Trigger (on handle) to initiate a
scan with the Pegaso.
2.
Aim the scan window at the bar code as shown in Figure 12.
3.
Press the  key or trigger. The laser scans as long as you hold the
button or trigger, or for 10 seconds, or until a good scan is obtained.
4.
Aim the laser beam at the center of the bar code.
• Position the unit close to bar code when scanning small bar codes.
• Position it at a distance when scanning larger bar codes.
• The laser is disabled after you release the key or after 10 seconds, or
once a good scan is obtained.
Figure 13. Laser Beam Positions
Correct Scanning Positions
Ideal positioning
A bit high, will read correctly
A bit angled, will read correctly
Incorrect Scanning Positions
Positioned too far to the right. Will
not read entire bar code.
Quick Reference Guide
Too angled;
entire
cannot read the
bar code.
Bar code will not read. The
scanner should be positioned perpendicular to
the bar code bars.
21
Persistent Memory
5.
The device beeps and the green LED indicator comes on until the trigger
is released. The green LED and the beep tone indicate a good read.
If the bar code scan failed, adjust the reading angle or distance. Make
sure that the laser beam scans across all bars of the bar code. Refer
to Figure 13.
6.
The bar code data is entered in the current application.
7.
Once a bar code is read successfully, the scanner turns off automatically.
Refer to Scanner Configuration in the PRG to modify the default settings.
Persistent Memory
In addition to the RAM-based storage standard on Windows CE terminals, the
Pegaso is equipped with persistent memory flash application and file storage
area. Refer to the PRG for more information.
The persistent storage memory persists across all reset (warm/cold
reboot) conditions and software / firmware updates.
Because of this, Datalogic very strongly recommends installing all
applications, applets, programs, and important data files to the persistent disk of the Pegaso.
If an application or a data file is only installed or saved in RAM, a hard
reset may result in the loss of that application or data file.
Context Sensitive Help
Microsoft Windows CE context sensitive help is available where ever “?”
appears in the upper right hand corner of the window. Press “?” to open the
context help window. Select/tap the desired item from the list of hot links.
Resetting the Pegaso
There are two reset methods for the Pegaso.
• A warm reset terminates an unresponsive application and clears the working RAM, but preserves the file system.
• A cold reset forces all applications to close and clears working RAM and
files not resident on the persistent flash memory.
22
Pegaso™ Industrial PDA with Windows® CE
Resetting the Pegaso
Datalogic recommends that you always attempt a warm reset before
initiating a cold reset. Once you initiate a cold reset, all applications
are forcibly closed and working RAM and files are cleared.
It is a good idea to store important data in flash (persistent) storage
for this reason. Refer to Persistent Memory on page 22. More informaCAUTION
tion can be found in the Pegaso PRG.
Warm Reset
A warm reset is a transition from the on or idle condition that closes all applications, clears the working RAM, but preserves the file system. If an application
“hangs,” initiate a warm reset to terminate the application.
Procedure to Warm Reset — The first two keys of the sequence can be
pressed in any order, but the unit will not reset until they both are held down
and then the third key () is pressed. All three keys must be held down for
the unit to reset. Refer to Figure 14 for the location of the reset keys.
19-Key Pegaso — Press and hold: ++.
Figure 14. Warm Reset
ESC
2 ABC
DEF
TAB
GHI
JKL
6 MNO
FN
7 PQRS
TUV
AZ
WXYZ
After Warm Reset
• The splash screen will appear briefly.
• The desktop appears with the application shortcuts on the screen.
• RF Network PC Card (if present) connects to the network system
The custom settings in the registry are persistent.
Quick Reference Guide
23
Resetting the Pegaso
Cold Reset
A cold reset is a complete reset of the Pegaso in which all applications are forcibly closed and working RAM is cleared.
Datalogic recommends that you always attempt a warm reset before
initiating a cold reset. Once you initiate a cold reset, all applications
are forcibly closed and working RAM and files are cleared.
Any applications, files, or data in RAM will be lost on cold reset. Only
CAUTION applications and files in persistent memory are preserved. Refer to
Persistent Memory on page 22 for information on preserving applications and files with persistent flash storage memory.
Reason to Cold Reset — Press the  button inside the Battery com-
partment when the Windows CE operating system locks up and the warm reset
command does not work.
Procedure to Cold Reset — To perform a cold reset, remove the Battery
Pack and use the Stylus to press the  button inside the Battery Compartment, shown in Figure 15 on page 24. Reinstall the Battery Pack, and press the
 button.
Figure 15. Cold Reset
Cold Reset Button
After Cold Reset
Cold reset clears the working RAM and initializes the file system. You will lose
any applications and data which are not stored in persistent flash memory (refer
to the PRG for more information).
• The splash screen will appear after a short period.
• Recalibrate the touch screen.
• The desktop appears with the application shortcuts on the screen.
24
Pegaso™ Industrial PDA with Windows® CE
Maintaining the Pegaso
• RF Network PC Card (if present) connects to the network system.
The custom settings in the registry are persistent.
Maintaining the Pegaso
With normal use, the Pegaso, Dock, and Four-Slot Battery Charger require no
maintenance. For trouble-free service, observe the following tips:
• To prolong its life and avoid problems, keep the Pegaso clean. Use a
clean, soft cloth dampened with a mild, dilute cleanser.
• Clean the display with a lens cloth or other soft cloth dampened with a
mild, dilute cleaning solution.
Never use a pen, pencil, or other sharp object on the display/touch
screen. Use only the supplied stylus or plastic-tipped pens intended
for use with a touch-sensitive screen.
Do not immerse the Pegaso, dock, or battery charger in liquid.
CAUTION Do not use abrasive paper/cloth or abrasive/corrosive cleaners to
clean the unit.
WARNING
Do not use a sharp object to Reset; use the Stylus. A sharp object
can puncture the button, disabling the reset function, rupturing the
industrial seal, and voiding your warranty. Refer to Resetting the
Pegaso on page 2-22
Troubleshooting
Refer to the Pegaso PRG for more information.
Table 7. Troubleshooting Problems, Causes, and Solutions
Problem
The Pegaso does
not turn on.
During boot, the
terminal beeps
twice and stays
blank.
Possible Cause
Solution
The battery pack is
Ensure the battery is installed properly.
not installed properly.
System failure.
Perform a cold reset. Refer to Resetting the
Pegaso on page 2-22.
Firmware persistent
flash memory has
been corrupted.
Re-download the firmware using the FUU in
bootload mode. Refer to the PRG.
Quick Reference Guide
25
Troubleshooting
Problem
Rechargeable
battery pack did
not charge.
Possible Cause
Battery failure.
Solution
Replace the battery. If the terminal still does
not work, do a warm reset, then a cold reset;
refer to Resetting the Pegaso on page 2-22.
The unit was removed Insert the Pegaso in dock and begin charging.
The battery pack and backup battery require 4
from the dock while
battery was charging. hours to fully charge.
The Pegaso is not
Press .
Characters are not powered on.
visible on the
The ambient room
The Ambient Light Sensor may not be functiondisplay.
light is too dark or low. ing properly.
No sound is
audible.
Adjust the sound by going to Start > Settings
Volume setting is low
> Control Panel > Volume & Sounds --OR -or turned off.
Scan a bar code from the PRG.
The Pegaso turns
itself off.
The Pegaso is inactive.
The Pegaso turns off after a period of inactivity.
You can set duration from 1-30 minutes. Refer
to the PRG.
The Pegaso was
removed from dock or
Replace the terminal in the dock or replace the
unplugged from host
serial cable, and retransmit.
During data
PC during communicommunication, no cations.
data was
Incorrect cable configtransmitted, or
See your System Administrator.
uration.
transmitted data
Communication softwas incomplete.
ware was incorrectly
Perform setup as described in the PRG.
installed or configured.
The scan window is
dirty.
Carefully wipe the scanning window with a soft,
clean cloth. Do not use abrasives.
The scanning applica- Verify unit is loaded with a scanning application is not loaded.
tion. See your System Administrator.
Unreadable bar code. Be sure the symbol is not defaced.
The Pegaso does
not accept scan
input.
Distance from scan
window to bar code is Be sure you are in proper scanning range.
incorrect.
The Pegaso is not
programmed for a
symbology.
26
Be sure the terminal is programmed to accept
the type of bar code you are scanning. Try
using FF3A to turn on maximum defaults, as
described in “Programming Parameters” in the
PRG.
Pegaso™ Industrial PDA with Windows® CE
Troubleshooting
Problem
Possible Cause
Solution
If you don’t hear a beep, check that the appliThe Pegaso is not
programmed to gener- cation is set to generate a beep on good
decode.
ate a beep.
The Pegaso does
not accept scan
input (cont.)
Battery is low.
The UPC/EAN
Laser beam only
extension
crosses over base of
(supplemental
label) is not always UPC/EAN label.
scanned.
Time-out fault: the
spare battery pack
charging has
exceeded the maximum time-out period.
If the scanner stops emitting a laser beam
when you press the trigger, check your battery
level. Refer to the PRG.
Note: If the scanner is still not reading
symbols, contact your distributor or
Datalogic Mobile, Inc.
Set the Read Verification for extensions
(parameter 0528) to a value lower than the
Read Verification for the base label. See the
PRG.
In either case, if the Spare Battery LED is
flashing red, do the following:
1. Disconnect the AC adapter from the dock.
2. Remove the spare battery pack and the
Pegaso from the dock.
3. Connect the AC adapter to the dock.
The Spare Battery
LED on the dock is Over-voltage fault: the
flashing RED.
spare battery pack
charging has
exceeded the maximum charge voltage
of the battery.
Quick Reference Guide
4. If the Spare Battery LED is flashing red,
there is a problem with the dock. Disconnect
the AC adapter from the dock and contact a
service technician.
5. If the Spare Battery LED is off, insert a different spare battery pack in the dock.
6. Otherwise, there is a problem with the first
spare battery pack. Discontinue use of the first
spare battery pack. Refer to the PRG for
instructions on battery disposal.
27
Troubleshooting
RF Connectivity Troubleshooting
Gather facts:
•
Falcon type
•
AP & RF card brand (ensure latest version of firmware installed)
•
Host type
•
Software type
•
Software version (ensure latest version is installed)
•
Frequency and duration of issue
START
Does the Falcon
respond to a PING
command from
a PC?
YES
Does the Falcon
display an error during the
boot process?
NO
Contact Tech Support.
NO
YES
Does the Falcon
associate with the AP
NO
Potential Problems:
• Security Issue – Check
SSID, WEP, LEAP settings
• Range Issue
YES
Potential Problems:
Ping Falcon from
host or use tracert to
determine the location
YES
of the breakdown in
communication.
Does the Falcon
connect to the host
YES
RF connectivity
obtained. See your
software manual for
further information or
contact Datalogic technical support.
NO
Can you ping the
Falcon from the AP
NO
NO
Can you ping the
host from a PC on same
subnet ?
Potential Problems:
• IP Address Issue
• Check security settings
Potential Problems:
• Host unavailable
YES
Potential Problems:
• IP address issue (duplicate address on Falcon). Tu rn off the Falcon and
attempt PING again
• Run t r ac ert command to determine location of breakdown of connectivity.
(For more information on the Ping command, go to the command prompt on the PC and type PING. For more information on the
trace route command, go to the command prompt on the PC and type tracert.)
28
Pegaso™ Industrial PDA with Windows® CE
Technical Support
Technical Support
Datalogic Mobile Website Support
The Datalogic Mobile website (www.mobile.datalogic.com) is the complete source for technical support and information for Datalogic products. The
site offers the Datalogic TekForum, product support, product registration, warranty information, product manuals, product tech notes, software updates,
demos, and instructions for returning products for repair.
Datalogic Mobile Website TekForum
Search for information on the TekForum on the Datalogic home page. Browse
the TekForum to find answers to your questions about common technical
issues.
Reseller Technical Support
An excellent source for technical assistance and information is an authorized
Datalogic reseller. A reseller is acquainted with specific types of businesses,
application software, and computer systems and can provide individualized
assistance.
Telephone Technical Support
If you do not have internet or email access, you may contact Datalogic technical
support at (541) 743-4802.
Resources
Check the Datalogic Mobile website at www.mobile.datalogic.com for the latest
updates for manuals, software and information about your product.
Quick Reference Guide
29
Resources
NOTES
30
Pegaso™ Industrial PDA with Windows® CE
Appendix A: Datalogic Mobile
Pegaso™ Windows® CE
End User License Agreement
Notice to End User: The Datalogic Product you have acquired contains Software, which is
integral to the product’s operation. This Software is being provided to you under license, subject to the terms and conditions of this Agreement. If you use the Datalogic Product, you will
be deemed to have accepted the terms and conditions of this Agreement. If you do not intend
to be bound to the terms of this Agreement, Datalogic is not willing to license the Software to
you, you may not use the Datalogic Product or the Software, and you must contact the party
from whom you acquired the Datalogic Product for instructions.
This End User Software License Agreement (“Agreement”) is a legally binding agreement
governing the licensing of the Software and Documentation by Datalogic Mobile, Inc. and its
wholly owned subsidiaries and affiliates (“Datalogic”) to the entity or person who has purchased or otherwise acquired a Datalogic Product (“End User”). For purposes of this Agreement, any software that is associated with a separate end-user license agreement is licensed
to you under the terms of that license agreement. Datalogic and End User hereby agree as
follows:
1. Definitions.
1.1 “Documentation” means materials such as user’s guides, program reference guides,
quick reference guides, manuals, or similar materials associated with or related to the Datalogic Product, whether in printed, “online”, or other form.
1.2 “Proprietary Information” means: (a) source code, object code, software, documentation,
and any related internal design, system design, data base design, algorithms, technology,
technical data or information, implementation techniques, and trade secrets related to the
Software, (b) any other trade secrets marked appropriately or identified as proprietary or confidential, and (c) any information that End User, under the circumstances, should recognize
as confidential. Proprietary Information does not include any information that the receiving
party can establish was (1) in the public domain, (2) already in the receiving party’s possession or rightfully known prior to receipt, (3) rightfully learned from a third party not in violation
of any other's proprietary rights, or (4) independently developed without access to Proprietary
Information.
1.3 “Datalogic Product” means Datalogic Mobile’s Pegaso Windows® CE .NET Series,
including all preloaded Software in or provided in connection with the Datalogic Product and
all Documentation related to such product, which has been purchased or otherwise acquired
by End User, whether obtained directly or indirectly from Datalogic.
1.4 “Software” means any software or computer programs of Datalogic or its third party licensors in machine readable form which is either preloaded in or provided in connection with the
Datalogic Product, whether obtained directly or indirectly from Datalogic, including any
related update or upgrade such as enhancements or modifications.
2. Scope Of License Granted.
2.1 Datalogic grants to End User a non-exclusive, non-transferable, perpetual license to use
the Software, solely on a Datalogic Product, in machine-readable form only, solely for End
Quick Reference Guide
31
User's internal business purposes. This Agreement does not convey ownership of the Software to End User. Title to the Software shall be and remain with Datalogic or the third party
from whom Datalogic has obtained a licensed right. As used in this Agreement, the term “purchase” or its equivalents when applied to the Software shall mean “acquire under license.”
2.2 End User shall not copy, modify, decompile, disassemble, reverse engineer, or otherwise
reproduce or remanufacture the Software, whether modified or unmodified, nor sell, assign,
sublicense, distribute, lend, rent, give, or otherwise transfer the Software to any other person
or organization, for purposes other than as expressly provided in this Agreement, or to the
extent specifically allowed under foreign law solely for the purposes of interoperability, without
Datalogic’s prior written consent.
3. Transfers, Support.
3.1 Any copying, installing, reproduction, remanufacture, reverse engineering, electronic
transfer, or other use of the Software on other than a Datalogic Product will be a material
breach of this Agreement.
3.2 End User shall not sell, assign, sublicense, distribute, lend, rent, give, or otherwise transfer a Datalogic Product containing Software to any third party unless such third party agrees
with Datalogic in writing to be bound by the terms and conditions of this Agreement. Any such
transfer of a Datalogic Product absent such agreement shall be null and void.
3.3 End User may obtain support for Software from Datalogic at Datalogic’s standard support
fees and under Datalogic’s standard support terms and conditions in effect at the time the
support is requested.
4. Intellectual Property.
End User acknowledges that the Software constitutes valuable trade secrets of Datalogic or
Datalogic’s third party licensors and that the Software is protected by intellectual property
laws and treaties. The license set forth in this Agreement does not transfer to End User any
ownership of Datalogic’s or its third party licensors' copyrights, patents, trademarks, service
marks, trade secrets, or other intellectual property rights and End User shall have no right to
commence any legal actions to obtain such rights. End User shall not remove, modify, or take
any other action that would obscure any copyright, trademark, patent marking, or other intellectual property notices contained in or on the Datalogic Product.
5. Proprietary Information.
5.1 End User acknowledges that Proprietary Information is the confidential, proprietary, and
trade secret property of Datalogic and Datalogic’s third party licensors and End User acquires
no right or interest in any Proprietary Information.
5.2 End User shall not disclose, provide, or otherwise make available the Proprietary Information of Datalogic or its third party licensors to any person other than End User’s authorized
employees or agents who are under confidentiality agreement, and End User shall not use
the Proprietary Information other than in conjunction with use of the Datalogic Product exclusively for End User’s internal business purposes. End User shall take steps to protect the Proprietary Information no less securely than if it were End User's own intellectual property.
5.3 The provisions of this Proprietary Information Section shall survive and continue for five
(5) years after the termination of this Agreement.
6. Limited Warranty.
6.1 Datalogic warrants that, under normal use and operation, the Datalogic Product will conform substantially to the applicable Documentation for the period specified in the Documenta-
32
Pegaso PDA with Windows® CE
tion. During this period, for all reproducible nonconformities for which Datalogic has been
given written notice, Datalogic will use commercially reasonable efforts to remedy nonconformities verified by Datalogic. End User agrees to supply Datalogic with all reasonably
requested information and assistance necessary to help Datalogic in remedying such nonconformities. For all defects reported to Datalogic within the warranty period, Datalogic’s liability is limited to providing End User with one copy of corrections or responding to End User's
problem reports according to Datalogic's standard assistance practices. Datalogic does not
warrant that the product will meet End User's requirements or that use of the product will be
uninterrupted or error free, or that Datalogic's remedial efforts will correct any nonconformance. This limited warranty does not cover any product that has been subjected to damage
or abuse, whether intentionally, accidentally, or by neglect, or to unauthorized repair or unauthorized installation, and shall be void if End User modifies the product, uses the product in
any manner other than as established in the Documentation, or if End User breaches any of
the provisions of this Agreement.
6.2 EXCEPT AS PROVIDED IN THIS AGREEMENT, THE DATALOGIC PRODUCT IS PROVIDED “AS IS” AND DATALOGIC MAKES NO WARRANTIES OF ANY KIND, EXPRESS OR
IMPLIED, WRITTEN OR ORAL, WITH RESPECT TO THE PRODUCT, AND SPECIFICALLY
DISCLAIMS THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A
PARTICULAR PURPOSE.
7. Infringement.
7.1 Datalogic will defend End User against any claim in a lawsuit that the Datalogic Product
furnished hereunder infringes a United States patent or copyright of a third party and Datalogic will pay any damages finally awarded against End User by a court of competent jurisdiction that are attributable to such claim or will pay End User’s part of any settlement that is
attributable to such claim, provided, that 1) End User notifies Datalogic promptly in writing of
the claim, 2) Datalogic controls the defense or settlement of the claim, and 3) End User cooperates fully with Datalogic in such defense or settlement. All notices of a claim should be sent
to Datalogic Mobile, Inc., 1505 Westec Drive, Eugene, OR 97402.
7.2 In the defense or settlement of any such claim, Datalogic may, at its option, 1) procure for
End User the right to continue using the Datalogic Product, 2) modify the Datalogic Product
so that it becomes non-infringing, 3) replace the Datalogic Product with an equivalent product
not subject to such claim, or 4) provide End User an opportunity to return the Datalogic Product and receive a refund of the purchase price paid, less a reasonable allowance for use.
7.3 Datalogic shall have no liability to End User for claims of infringement based upon 1) the
use of any Datalogic Product in combination with any product which Datalogic has not either
furnished or authorized for use with such Datalogic Product 2) the use of any Datalogic Product designed, manufactured, or modified to the specifications of End User, or 3) End User’s
modification of the Datalogic Product without written authorization from Datalogic.
7.4 THE FOREGOING STATES DATALOGIC’S COMPLETE AND ENTIRE OBLIGATION
CONCERNING CLAIMS OF PATENT, COPYRIGHT, OR OTHER INTELLECTUAL PROPERTY INFRINGEMENT, CANCELS AND SUPERCEDES ANY PRIOR AGREEMENTS,
WHETHER ORAL OR WRITTEN, BETWEEN THE PARTIES CONCERNING SUCH
CLAIMS, AND WILL NOT BE MODIFIED OR AMENDED BY ANY PAST, CONTEMPORANEOUS, OR FUTURE AGREEMENTS OR DEALINGS BETWEEN THE PARTIES, WHETHER
ORAL OR WRITTEN, EXCEPT AS SET FORTH IN A FUTURE WRITING SIGNED BY BOTH
PARTIES.
8. Limitation Of Liability.
EXCEPT AS PROVIDED IN SECTION 7, DATALOGIC SHALL NOT BE LIABLE FOR ANY
CLAIMS AGAINST END USER BY ANY OTHER PARTY. IN NO EVENT SHALL DATA-
Quick Reference Guide
33
LOGIC'S LIABILITY FOR DAMAGES, IF ANY, WHETHER BASED UPON CONTRACT,
TORT (INCLUDING NEGLIGENCE), PRODUCT LIABILITY, STRICT LIABILITY, WARRANTY, OR ANY OTHER BASIS, EXCEED THE PRICE OR FEE PAID BY END USER FOR
THE DATALOGIC PRODUCT. UNDER NO CIRCUMSTANCES SHALL DATALOGIC BE LIABLE TO END USER OR ANY THIRD PARTY FOR LOST PROFITS, LOST DATA, INTERRUPTION OF BUSINESS OR SERVICE, OR FOR ANY OTHER SPECIAL,
CONSEQUENTIAL, CONTINGENT, INDIRECT, INCIDENTAL, PUNITIVE, EXEMPLARY, OR
OTHER SIMILAR DAMAGES, EVEN IF DATALOGIC HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES.
9. Government Restricted Rights; International Use.
9.1 Use, duplication, or disclosure of the Software by the U.S. Government is subject to the
restrictions for computer software developed at private expense as set forth in the U.S. Federal Acquisition Regulations at FAR 52.227-14(g), or 52.227-19 or in the Rights in Technical
Data and Computer Software clause at DFARS 252.227-7013(c)(1)(ii), whichever is applicable.
9.2 If End User is using the Datalogic Product outside of the United States, End User must
comply with the applicable local laws of the country in which the Datalogic Product is used,
with U.S. export control laws, and with the English language version of this Agreement. The
provisions of the “United Nations Convention on International Sale of Goods” shall not apply
to this Agreement.
10. Termination.
10.1 Either party may terminate this Agreement or any license granted under this Agreement
at any time upon written notice if the other party breaches any provision of this Agreement.
10.2 Upon termination of this Agreement, End User immediately shall cease using any nonpreloaded software and shall return to Datalogic or destroy all non-preloaded software covered by this Agreement, and shall furnish Datalogic with a certificate of compliance with this
provision signed by an officer or authorized representative of End User. For preloaded software, End User agrees to sign a waiver prepared by Datalogic concerning further use of the
preloaded Software. End User’s resumed or continued use of the preloaded Software after
termination shall constitute End User’s agreement to be bound by the terms and conditions of
this Agreement for such use.
11. General Provisions.
11.1 Entire Agreement; Amendment. This document contains the entire agreement between
the parties relating to the licensing of the Software and supersedes all prior or contemporaneous agreements, written or oral, between the parties concerning the licensing of the Software. This Agreement may not be changed, amended, or modified except by written
document signed by Datalogic.
11.2 Notice. All notices required or authorized under this Agreement shall be given in writing,
and shall be effective when received, with evidence of receipt. Notices to Datalogic shall be
sent to the attention of the Legal Department, General Counsel, Datalogic Mobile, Inc., 1505
Westec Drive, Eugene, OR 97402, or such other address as may be specified by Datalogic in
writing.
11.3 Waiver. A party’s failure to enforce any of the terms and conditions of this Agreement
shall not prevent the party’s later enforcement of such terms and conditions.
11.4 Governing Law; Venue: This Agreement and the rights of the parties hereunder shall be
governed by and construed in accordance with the laws of the State of Oregon U.S.A, without
regard to the rules governing conflicts of law. The state or federal courts of the State of Ore-
34
Pegaso PDA with Windows® CE
gon located in either Multnomah or Lane counties shall have exclusive jurisdiction over all
matters regarding this Agreement, except that Datalogic shall have the right, at its absolute
discretion, to initiate proceedings in the courts of any other state, country, or territory in which
End User resides, or in which any of End User's assets are located.
11.5 Attorneys’ Fees. In the event an action is brought to enforce the terms and conditions of
this Agreement, the prevailing party shall be entitled to reasonable attorneys’ fees, both at
trial and on appeal.
- END -
Quick Reference Guide
35
Appendix B: Microsoft® Windows®
CE End User License Agreement
Datalogic is contractually obligated by Microsoft® to include the following information as part
of our software end user license agreement:
You have acquired a device (“DEVICE”) that includes software licensed by Datalogic from
Microsoft Licensing Inc. or its affiliates (“MS”). Those installed software products of MS origin,
as well as associated media, printed materials, and “'online” or electronic documentation
(“SOFTWARE”) are protected by international intellectual property, laws and treaties. The
SOFTW.ARE is licensed, not sold. All rights reserved.
IF YOU DO NOT AGREE TO THIS END USER LICENSE AGREEMENT (“EULA”), DO NOT
USE THE DEVICE OR COPY THE SOFTWARE, INSTEAD, PROMPTLY CONTACT DATALOGIC FOR INSTRUCTIONS ON RETURN OF THE UNUSED DEVICE(S) FOR A REFUND.
ANY USE OF THE SOFTWARE, INCLUDIING BUT NOT LIMITED TO USE ON THE
DEVICE, WILL CONSTITUTE YOUR AGREEMENT TO THIS EULA (OR RATIFICATION OF
ANY PREVIOUS CONSENT).
GRANT OF SOFTWARE LICENSE, This EULA grants you the following license:
•
You may use the SOFTWARE only on the DEVICE.
•
NOT FAULT TOLERANT. THE SOFTWARE IS NOT FAULT TOLERANT. DATALOGIC
HAS INDEPENDENTLY DETERMINED HOW TO USE THE SOFTWARE IN THE
DEVICE, AND MS HAS RELIED UPON DATALOGIC TO CONDUCT SUFFICIENT
TESTING TO DETERMINE THAT THE SOFTWARE IS SUITABLE FOR SUCH USE.
•
NO WARRANTIES FOR THE SOFTWARE. THE SOFTWARE is provided “AS IS” and
with all faults. THE ENTIRE RISK AS TO SATISFACTORY QUALITY, PERFORMANCE,
ACCURACY, AND EFFORT (INCLUDING LACK OF NEGLIGENCE) IS WITH YOU.
ALSO, THERE IS NO WARRANTY AGAINST INTERFERENCE WITH YOUR ENJOYMENT OF THE SOFTWARE OR AGAINST INFRINGEMENT, IF YOU HAVE
RECEIVED ANY WARRANTIES REGARDING THE DEVICE OR THE SOFTWARE,
THOSE WARRANTIES DO NOT ORIGINATE FROM, AND ARE NOT BINDING ON,
MS.
•
Note on Java Support. The SOFTWARE may contain support for programs written in
Java. Java technology is not fault tolerant and is not designed, manufactured, or
intended for use or resale as online control equipment in hazardous environments
requiring fail-safe performance, such as in the operation of nuclear facilities, aircraft navigation or communication systems, air traffic control, direct life support machines, or
weapons systems, in which the failure of Java technology could lead directly to death,
personal injury, or severe physical or environmental damage. Sun Microsystems, Inc.
has contractually obligated MS to make this disclaimer.
•
No Liability for Certain Damages. EXCEPT AS PROHIBITED BY LAW, MS SHALL
HAVE NO LIABILITY FOR ANY INDIRECT, SPECIAL, CONSEQUENTIAL OR INCIDENTAL DAMAGES ARISING FROM OR IN CONNECTION WITH THE USE OR PERFORMANCE OF THE SOFTWARE. THIS LIMITATION SHALL APPLY EVEN IF ANY
REMEDY FAILS OF ITS ESSENTIAL PURPOSE. IN NO EVENT SHALL MS BE LIABLE FOR ANY AMOUNT IN EXCESS OF U.S. TWO HUNDRED FIFTY DOLLARS
(U.S. $250.00).
•
Limitations on Reverse Engineering, Decompilation, and Disassembly, You may not
reverse engineer, decompile, or disassemble the SOFTWARE, except and only to the
36
Pegaso PDA with Windows® CE
extent that such activity is expressly permitted by applicable law notwithstanding this
limitation.
•
SOFTWARE TRANSFER ALLOWED BUT WITH RESTRICTIONS. You may permanently transfer rights under this EULA only as part of a permanent sale or transfer of the
Device, and only if the recipient agrees to this EULA. If the SOFTWARE is an upgrade,
any transfer must also include all prior versions of the SOFTWARE.
•
EXPORT RESTRICTIONS, You acknowledge that SOFTWARE is of US-origin. You
agree to comply with all applicable international and national laws that apply to the
SOFTWARE, including the U.S. Export Administration Regulations, as well as end-user,
end-use and country destination restrictions issued by U.S. and other governments. For
additional information on exporting the SOFTWARE, see http://www.microsoft.com/
exporting/.
Quick Reference Guide
37
Appendix C: Datalogic Mobile
Pegaso Windows® CE
Product Warranty
Warranty
Pegaso products are guaranteed against defects in materials and workmanship for the period
specified at the time of sale. This warranty shall apply to Pegaso PDAs, Base Stations for the
Pegaso and Chargers for the Pegaso. Cables, mounts and other accessory items are specifically warranted for a period of 90-days from product purchase. Customer must notify Datalogic of the claimed defect before the expiration of the Warranty period and obtain from
Datalogic a return authorization number for return of the product to designated Datalogic service center. If Datalogic determines Customer’s claim is valid, Datalogic will repair or replace
product without additional charge for parts and labor. Customer shall be responsible for packaging and shipping the product to the designated Datalogic service center, with shipping
charges prepaid. Datalogic shall pay for the return of the product to Customer if the shipment
is to a location within the country in which the Datalogic service center is located. Customer
shall be responsible for paying all shipping charges, duties, taxes, and any other charges for
products returned to any other locations.
Warranty is subject to the limitations and exclusions set forth in the paragraphs that follow.
WARRANTY SET FORTH ABOVE IS IN LIEU OF ANY OTHER WARRANTIES, EXPRESS
OR IMPLIED, INCLUDING MERCHANTABILITY AND FITNESS.
Exclusions
Warranty coverage shall not apply to any claimed defect, failure or damage which Datalogic
determines was caused by: abuse, neglect, improper use of product; failure to provide product maintenance, including but not limited to cleaning of the display in accordance with product reference guide; installation or service of product by other than Datalogic representatives;
use of product with any other instrument, equipment or apparatus; modification or alteration
of product or units with Warranty Void labels that have been tampered with. External cables
and replacement of upper window/cartridge due to scratching, stains or other degradation will
not be covered under the Warranty. External power supplies returned for service must be
accompanied by the original product for performance of service.
Returned products that Datalogic has determined are not covered by Warranty, will be
charged Datalogic standard repair rates then in effect for repair of product. Replacement of
display due to scratching, stains or other degradation will not be covered under Warranty. If a
product is determined to be not repairable customer will be notified and product may be
returned to customer at their request. A minimum repair fee may be charged.
Limitation of Liability
DATALOGIC's REPAIR OR REPLACEMENT OF DEFECTIVE PRODUCT AS SET FORTH
ABOVE IS THE CUSTOMER’S SOLE AND EXCLUSIVE REMEDY ON ACCOUNT OF
CLAIMS OF BREACH OF WARRANTY OR PRODUCT DEFECT. UNDER NO CIRCUMSTANCES WILL DATALOGIC BE LIABLE TO CUSTOMER OR ANY THIRD PARTY FOR
ANY LOST PROFITS, OR ANY INCIDENTAL, CONSEQUENTIAL IN-DIRECT, SPECIAL OR
CONTINGENT DAMAGES REGARDLESS OF WHETHER DATALOGIC HAD ADVANCE
NOTICE OF THE POSSIBILITY OF SUCH DAMAGES.
38
Falcon® P20/P40 with Windows® CE
Assignment
Customer may not assign or otherwise transfer its rights or obligations under Warranty except
to a purchaser or transferee of product. No attempted assignment or transfer in violation of
this provision shall be valid or binding upon Datalogic.
Risk of Loss
Customer shall bear risk of loss or damage for product in transit to Datalogic. Datalogic shall
assume risk of loss or damage for product in Datalogic's possession or product being
returned to Customer by Datalogic, except such loss or damage as may be caused by the
negligence of Customer, its agents or employees. In the absence of specific written instructions for the return of product to Customer, Datalogic will select the carrier, but Datalogic shall
not thereby assume any liability in connection with the return shipment.
Quick Reference Guide
39
Appendix D. Safety and Regulatory
Information
Laser Safety Label
Figure 16. Laser Safety Label
CLASS 2 LASER PRODUCT 1.0mW
Max Output: 645 to 660nM
Complies with 21 CFR
1040.10 and1040.11
EN60825 1+A2:2001
This figure illustrates an example of a laser safety
label, which is located on the scanning pod of
laser-based Pegaso units. The label on your unit
may appear different or have different information. Please refer to your unit for specific laser
safety requirements.
The Advanced Long Range Laser is rated Class
3R per EN60825-1 and Class II per CFR 1040.
Models with the Linear Imager are rated LED
Class 1 per IEC 60 825-1:2001, only.
Advisory Statement
Use of controls, adjustments, or performance of procedures
other than those specified herein may result in hazardous
CAUTION visible or invisible laser light exposure.
Regulatory Statements
Federal Communication Commission
Interference Statement
This equipment has been tested and found to comply with the limits for a Class
B digital device, pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment off and on, the
user is encouraged to try to correct the interference by one of the following measures:
•
Reorient or relocate the receiving antenna.
•
Increase the separation between the equipment and receiver.
40
Pegaso PDA with Windows® CE
•
Connect the equipment into an outlet on a circuit different from that to
which the receiver is connected.
•
Consult the dealer or an experienced radio/TV technician for help.
FCC Caution: Any changes or modifications not expressly approved by the
party responsible for compliance could void the user's authority to operate this
equipment.
This device complies with Part 15 of the FCC Rules. Operation is subject to the
following two conditions: (1) This device may not cause harmful interference,
and (2) this device must accept any interference received, including interference
that may cause undesired operation.
The availability of some specific channels and/or operational frequency bands
are country dependent and are firmware programmed at the factory to match
the intended destination. The firmware setting is not accessible by the end user.
Table 8. Pegaso Family Radio Configurations
FALCON
CLASS
MODEL
NUMBER
FCC ID:
U4SPA
IC: 3862C-PA
P20-1001
802.11g
P40-0001
FCC ID:
U4SPB
IC:3862C-PB
FCC ID:
FCC ID:
U4SPC
U4SPD
IC: 3862C-PC IC: 3862C-PD
Bluetooth
P40-1001
P40-2001
Bluetooth
and 802.11g
Bluetooth,
802.11g, and
GSM
IMPORTANT NOTE:
Radiation Exposure Statement:
This equipment complies with FCC radiation exposure limits set forth for an
uncontrolled environment. End users must follow the specific operating instructions for satisfying RF exposure compliance. To maintain compliance with FCC
RF exposure compliance requirements, please follow operation instruction as
documented in this manual.
For body worn operation, this device has been tested and meets the FCC RF
exposure guidelines when used with Datalogic accessories supplied or designated for this product. Use of other accessories may not ensure compliance with
FCC RF exposure guidelines.
Quick Reference Guide
41
Industry Canada statement:
This device complies with RSS-210 of the Industry Canada Rules. Operation is
subject to the following two conditions: (1) This device may not cause harmful
interference, and (2) this device must accept any interference received, including
interference that may cause undesired operation.
IMPORTANT NOTE:
Radiation Exposure Statement:
This equipment complies with IC radiation exposure limits set forth for an
uncontrolled environment. End users must follow the specific operating instructions for satisfying RF exposure compliance. To maintain compliance with IC
RF exposure compliance requirements, please follow operation instruction as
documented in this manual.
For information about the disposal of Waste Electrical and
Electronic Equipment (WEEE), please refer to the Datalogic
Mobile website at www.mobile.datalogic.com.
42
Pegaso PDA with Windows® CE
Appendix E: Laser Safety
International Caution Statements for CLASS
11, 22, 3R3, II4, and IIA5 Laser Devices
English
Datalogic scanners are certified in the U.S. to conform to the requirements of DHHS/
CDRH 21CFR Subchapter J and to the requirements of IEC/EN 60825-1:1998-2001.
Class 1, 2, 3R, Class II, and IIA products are not considered to be hazardous. The scanner contains internally a Visible Laser Diode (VLD) whose emissions do not exceed the
maximum limits as set forth in the above regulations. The scanner is designed so that
there is no human access to harmful laser light during normal operation, user maintenance or during prescribed service operations.
CAUTION
If the scan pattern is a single dot when depressing the trigger, discontinue operation and
return the scanner to Datalogic.
CAUTION
Do not attempt to open or otherwise service any components in the optics cavity. Opening or servicing any part of the optics cavity by unauthorized personnel may violate laser
safety regulations. The optics system is a factory only repair item.
CAUTION
Use of optical systems with the scanner will increase eye hazard. Optical instruments
include binoculars, microscopes and magnifying glasses. This does not include eye glasses
worn by the user.
French
Ce scanneurs du Datalogic sont certifié conforme à la norme DHHS/CDRH 21CFR
sous-chapitre J et à la norme IEC/EN 60825-1:1998-2001.
Les produits de class 1, 2, 3R, class II, et de IIA ne sont pas considérés dangereux. Le
scanneur contient une diode laser visible (VLD) dont les émissions ne dépassent pas les
limites prescrites dans les normes précitées. Le scanneur est conçu de façon à ce qu’il ne
soit pas possible d’accéder à la lumière laser pendant l’utilisation normale, l’entretien par
l’utilisateur et les fonctions de maintenance prescrites.
1.
2.
3.
4.
5.
Class 1 applies to IEC/EN STD (Europe).
Class 2 applies to IEC/EN STD (Europe).
Class 3R applies to the Falcon 44xx using ALR (Advanced Long Range) Laser, only.
Class II applies to CDRH STD (US/Canada).
Class IIA applies to CDRH STD (US/Canada).
Quick Reference Guide
43
ATTENTION
Si, quand la fonction de balayage est lancée, le diagramme de balayage est constitué d’un
seul point, cesser d’utiliser le scanneur et le retourner à Datalogic.
ATTENTION
Ne pas essayer d’ouvrir ou de réparer les composants de la cavité optique. L’ouverture de
la cavité optique ou la réparation de ses composants par une personne non qualifiée peut
entraîner le non-respect des règles de sécurité relatives au laser. Le système optique ne
peut être réparé qu’en usine.
ATTENTION
L’utilisation d’instruments optiques avec le scanneur augmente le danger pour les yeux.
Les instruments optiques comprennent les jumelles, les microscopes et les verres grossissants. Ils ne comprennent pas les lunettes portées par l’utilisateur.
German
Dieser Scanner ist den in den Vereinigten Staaten geltenden Vorschriften des DHHS/
CDRH 21 CFR Subchapter J und den Vorschriften der IEC/EN 60825-1:1998-2001
entsprechend bescheinigt.
Produkte der Klasse 1, 2, 3R, Klasse II oder der IIA sind als ungefährlich eingestuft. Im
Inneren des Scanners befindet sich eine VLD (Visible Laser Diode), deren Ausstrahlung
die in den oben genannten Vorschriften angeführten Höchstgrenzen nicht überschreitet.
Die Konstruktion des Scanners garantiert, daß bei normalem Betrieb, bei Wartung durch
den Benutzer oder im Laufe planmäßiger Wartungsarbeiten kein Zugang zu schädlichem
Laserlicht besteht.
VORSICHT:
Sollte das Abtastbild bei gedrücktem Auslöser aus einem einzigen Punkt bestehen, muß
der Betrieb eingestellt und der Scanner an Datalogic zurückgesendet werden.
VORSICHT:
Unter keinen Umständen darf versucht werden, die Komponenten im Optikhohlraum
zu öffnen oder auf irgendwelche andere Weise zu warten. Das Öffnen bzw. Warten der
Komponenten im Optikhohlraum durch unbefugtes Personal verstößt gegen die LaserSicherheitsbestimmungen. Das Optiksystem darf nur werkseitig repariert werden.
VORSICHT:
Die Verwendung von Optiksystemen mit diesem Scanner erhöht die Gefahr einer
Augenbeschädigung. Zu optischen Instrumenten gehören unter anderem Ferngläser,
Mikroskope und Vergrößerungsgläser, nicht aber die von Benutzern getragenen Brillen.
Italian
È stato certificato che questo scanner si conforma ai requisiti della sezione J della normativa DHHS/CDRH 21CFR, e anche ai requisiti di IEC/EN 60825-1:1998-2001.
I prodotti di Classe 1, 2, 3R, Classe II, o IIA non sono considerati pericolosi. Lo scanner
contiene al suo interno un Visible Laser Diode (VLD), diodo laser visibile, le cui emissioni non eccedono i limiti stabiliti dalle normative sunnominate. Lo scanner è progettato in modo che non ci sia alcun accesso alla luce dannosa del laser nel corso di uso
normale, di manutenzione da parte dell’utente o durante la manutenzione periodica stabilita.
44
Pegaso PDA with Windows® CE
ATTENZIONE
Se, quando si preme l’azionamento, il pattern di scansione è un punto singolo, interrompere l’operazione e riportare lo scanner a Datalogic .
ATTENZIONE
Non tentare di accedere allo scomparto contenete i componenti ottici o di farne la
manutenzione. L’apertura dello scomparto, o la manutenzione di qualsiasi parte ottica da
parte di personale non autorizzato, potrebbe violare le norme della sicurezza. Il sistema
ottico può essere riparato solamente alla fabbrica.
ATTENZIONE
L’uso di strumenti ottici assieme allo scanner può aumentare il pericolo di danno agli
occhi. Tali strumenti ottici includono cannocchiali, microscopi e lenti di ingrandimento.
Essi non includono gli occhiali indossati dall’utente.
Danish
Denne scanner opfylder de amerikanske krav stillet i "DHHS/CDRH 21CFR Subchapter J" og opfylder også de krav, der stilles i IEC/EN 60825-1:1998-2001.
Klasse 1, 2, 3R, klasse II eller klasse IIA produkter anses for at være sikre. Scanneren
indeholder en Visible Laser Diode (VLD), der ikke overskrider maksimumgrænserne,
som beskrevet i ovenstående reglement. Scanneren er konstrueret, så der ikke er nogen
menneskelig kontakt medskadelige niveauer af laserbestråling under normal brug, normal vedligeholdelse eller under foreskrevet servicering.
ADVARSEL
Hvis scanningmønsteret er et enkelt punkt, når triggeren indtrykkes, skal betjening
ophøre og scanneren returneres til Datalogic.
ADVARSEL
Forsøg ikke at åbne eller reparere komponenter i det optiske hulrum. Uautoriseret åbning
eller reparation af komponenter i det optiske hulrum kan være en overtrædelse af lasersikkerhedsregulativer. Det optiske system må udelukkende repareres as Datalogic.
ADVARSEL
Anvendelse af optiske systemer med scanneren øger risikoen for øjenskader. Optiske
instruments omfatter kikkerter, mikroskoper og lupper. Det omfatter ikke anvendelse af
almindelige briller.
Dutch
Deze scanner is in de V.S. goedgekeurd en voldoet aan de vereisten van DHHS/CDRH
21CFR Subchapter J een aan de vereisten van IEC/EN 60825-1:1998-2001.
Producten van klasse 1 ,2, 3R, klasse II en IIA worden niet geacht gevaarlijk te zijn.
De scanner bevat een inwendige Visible Laser Diode (VLD) waarvan de emissies de maximumgrenzen van bovenstaande reglementen niet overschrijden.
De scanner is zo ontworpen dat men bij normaal gebruik, onderhoud of tijdens het
uitvoeren van de voorgeschreven onderhoudswerkzaamheden niet aan schadelijke niveaus
wordt blootgesteld.
Quick Reference Guide
45
WAARSCHUWING
Als het scanpatroon bij het overhalen van de trekker een enkele stip is, stop dan onmiddellijk en stuur de scanner terug naar Datalogic.
WAARSCHUWING
Probeer niet om onderdelen in de opticaruimte te openen of er onderhoud aan uit te
voeren. Het openen of onderhouden van delen in de opticaruimte door onbevoegd personeel kan een inbreuk vormen op de laserveiligheidsreglementen. Het opticasysteem
mag alleen in de fabriek worden gerepareerd.
WAARSCHUWING
Het gebruik van optische systemen samen met de scanner vergroot het risico voor de
ogen. Optische instrumenten zijn onder andere binoculairs, microscopen en vergrootglazen, maar niet de bril die de gebruiker draagt.
Swedish
Denna scanner uppfyller de amerikanska kraven DHHS/CDRH 21CFR Subchapter J
samt kraven i IEC/EN 60825-1:1998-2001.
Produkter i Klass 1, 2, 3R, Klass II och IIA anses ej farliga. Scannern är utrustad med en
intern, synlig laserdiod (Visible Laser Diode - VLD) vars emission inte överstiger max.
värdena i ova stående säkerhetsföreskrifter. Scannern har konstruerats så att personer vid
normal användning, bruksunderhåll och föreskriven service inte utsätts för skadlig laserstrålning.
VAR FÖRSIKTIG
Om scanningsmönstret är en enda punkt när du trycker på avtryckaren, ska du avbryta
användningen och ta scannerna tillbaka till Datalogic.
VAR FÖRSIKTIG
Försök inte öppna eller reparera komponenter i den optiska kamaren. Om icke auktoriserad personal öppnar eller reparerar delar i den optiska kammaren, kan detta strida mot
säkerhetsföreskrifterna för laserutrustning. Det optiska systemet får endast repareras på
fabriken.
VAR FÖRSIKTIG
Användning av optiska system med scannern ökar risken för ögoskada. Optiska instrument inkluderar kikare, mikroskop och förstoingsglas, men inte användarens glasögon.
Finnish
Tämä tutkain on hyväksytty Yhdysvalloissa vastaamaan DHHS/CDRH 21CFR Subchapter J luokka 60825-1:1998-2001 IEC/EN-vaatimuksia.
Luokka 1, 2, 3R, Luokka II tai IIAtuotteiden ei katsota olevan vaarallisia. Tutkain sisältää
sisäisen näkyvän laserdiodin (Visible Laser Diode (VLD), jonka päästöt eivät ylitä yllä
olevien säädösten asettamia maksimirajoja. Tutkain on suunniteltu siten, etteivät ihmiset
altistu vaaralliselle lasersäteilylle normaalikäytön, käyttäjän suorittaman huollon tai
ohjeiden mukaisten huoltotoimenpiteiden aikana.
VAROITUS
Jos skannauskuva on yksittäinen piste laukaisinta painettaessa, keskeytä käyttö ja palauta
tutkain Datalogic:lle.
46
Pegaso PDA with Windows® CE
VAROITUS
Älä yritä avata tai muuten huoltaa mitään rakenneosia optisessa osassa. Valtuuttamattoman henkilöstön suorittaman optisen osan avauksen tai huoltotoimen voidaan katsoa
olevan rikkomus lasersuojaohjeita vastaan. Optisen järjestelmän saa korjata ainoastaan
tehtaalla.
VAROITUS
Mikäli optisia järjestelmiä käytetään tutkainmen kanssa, silmille aiheutuva vaara lisääntyy. Optiset kojeet käsittävät kiikarit, mikroskoopit ja suurennuslasit. Käyttäjän silmälasit
eivät kuulu tähän ryhmään.
Norwegian
Denne skanneren er godkjent i USA i samsvar med retningslinjene for DHHS/CDRH
21CFR, avsnitt J, og til IEC/EN 60825-1:1998-2001.
Produkter i klasse 1 2, 3R, klasse II eller IIA ansees ikke som helsefarlige. Skanneren
inneholder en innvendig, synlig laserdiode (VLD, Visible Laser Diode), som ikke overskrider maksimalgrensene som er fastsatt i retningslinjene ovenfor. Skanneren er konstruert, slik at personer ikke utsettes for farlige doser med laserstråler ved normal drift,
brukers vedlikehold eller ved foreskrevet service.
OBS!
Hvis skanningsmønsteret består av én enkel prikk når utløseren trykkes inn, skal driften
stanses, og skanneren settes tilbake til Datalogic.
OBS!
Prøv ikke å åpne eller på noen måte utføre service på noen av delene i det optiske kammeret. Ved å åpne eller utføre service på noen av delene i det optiske kammeret av uautorisert personell, kan krenke forskriftene for lasersikkerhet. Optikksystemet skal bare
repareres på fabrikken.
OBS!
Bruk av optiske systemer med skanneren kan innebære høyere fare for øynene. Optiske
instrumenter innbefatter, kikkerter, mikroskop og forstørrelsesglass. Dette omfatter ikke
briller som brukeren har
på seg.
Portuguese
Este scanner foi certificado nos EUA para atender os requisitos do subcapítulo J do
DHHS/CDRH 21 CFR e os requisitos do IEC/EN 60825-1:1998-2001.
Os produtos da Classe 1, 2, 3R, Classe II ou IIA não são considerados perigosos. O scanner contém internamente um Diodo de Laser Visível (VLD - Visible Laser Diode) cujas
emissões não ultrapassam os limites definidos nos regulamentos mencionados acima. O
scanner foi projetado de maneira que não exista acesso humano à luz de laser nociva
durante a operação normal, manutenção pelo usuário ou durante as operações
recomendadas de serviço.
CUIDADO
Se ao pressionar o gatilho a luz do laser for um único ponto, interrompa a operação e
devolva o scanner à Datalogic.
Quick Reference Guide
47
CUIDADO
Não tente abrir ou consertar qualquer componente da cavidade óptica. A abertura ou
manutenção de qualquer peça da cavidade óptica por pessoal não autorizado pode infringir os regulamentos de segurança do laser. O sistema óptico só deve ser reparado na
fábrica.
CUIDADO
O uso de instrumentos ópticos com o scanner aumenta o risco para a visão. Incluem-se
entre os instrumentos ópticos os binóculos, microscópios e lentes de aumento. Não se
incluem os óculos usados pelo usuário.
Spanish
Este escáner está certificado en los EE.UU. porque reúne los requisitos DHHS/CDRH
21CFR Sección J y los requisitos de IEC/EN 60825-1:1998-2001.
Los productos de Clase 1, 2, 3R, Clase II, o IIA no se consideran como peligrosos. El
escáner tiene en su interior un Diodo Láser Visible (VLD) cuyas emisiones no exceden
los límites máximos fijados en los reglamentos mencionados anteriormente. El escáner
está diseñado de modo que las personas no tengan acceso a la luz láser peligrosa durante
la operación normal, el mantenimiento por parte del usuario o durante las operaciones de
servicio prescritas.
PRECAUCIÓN
Si al oprimir el interruptor, el patrón de exploración es un solo punto, discontinúe el uso
y devuelva el escáner a Datalogic.
PRECAUCIÓN
No intente abrir o de ninguna manera dar servicio a ninguno de los componentes del
receptáculo óptico. Abrir o dar servicio a las piezas del receptáculo óptico por parte del
personal no autorizado podría ser una violación a los reglamentos de seguridad. El
sistema óptico se puede reparar en la fábrica solamente.
PRECAUCIÓN
El uso de sistemas ópticos con el escáner aumentará el riesgo de daños oculares. Los
instrumentos ópticos incluyen binoculares, microscopios y lupas. Esto no incluye los
lentes recetados usados por el usuario.
48
Pegaso PDA with Windows® CE
Chinese
Datalogic
Quick Reference Guide
49
Japanese
Datalogic
50
Pegaso PDA with Windows® CE
NOTES
Quick Reference Guide
51
NOTES
52
Pegaso PDA with Windows® CE
DECLARATION OF CONFORMITY -
Datalogic hereby declares that the Equipment specified below has been tested
and found compliant to the following Directives and Standards:
EU Directives: 89/336/EEC EMC
73/23/EEC Low Voltage
R&TTE 1999/5/EC
Standards: EN300 328 V1.6.1 (2004-11) - Radio
EN 55022:1998+A1:2000+:2003, Class B - Generic Emission
EN 55024:1998+A1:2001+A2:2003 - Generic Immunity
EN301 489-17:2002/2005 - Radio Immunity
IEC60950-1:2001 - ITE Safety
EN60825-1/A2:2001 - Laser Safety
EN50361:2001 - Human Absorption Rate
EN50371:2002 - Human Exposure
EN 301 489-1 V1.6.1:2005
EN 50392:2004
IEEE 1528-2003
Equipment Type: Portable Data Terminal Equipment
Product Name: Pegaso, Four-Slot Battery Charger, Single Slot Dock Stations
Placed into EU Service: June 2007.
Responsible Manufacturer: Datalogic Mobile, Inc. 1505 Westec Dr., Eugene, OR USA
Declaration of Conformity with Regard to the R&TTE Directive 1999/5/EC
English:
This equipment is in compliance with the essential requirements & other relevant provisions of Directive 1999/5/EC.
Nederlands:
Deze apparatuur voldoet aan de essentiële vereisten en andere relevante voorzieningen
van EU-richtlijn 1999/5/EC.
Suomalainen: Tämä laite noudattaa direktiivin 1999/5/EC keskeisiä vaatimuksia ja sen muita olennaisia
määräyksiä.
Français:
Cet équipement répond aux exigences et provisions de la Directive 1999/5/EC.
Deutsch:
Diese Geräte entsprechen den Anforderungen und anderen relevanten Bestimmungen
der Richtlinie 1999/5/EC.
Italiano:
Questa apparecchiatura rispetta i requisiti essenziali e le altre clausole rilevanti della
Direttiva 1999/5/CE.
Dansk:
Dette utstyret er i samsvar med de grunnleggende kravene og andre relevante forskrifter i
1999/5/EC-direktivet.
Português:
Este equipamento está de acordo com os requisitos essenciais e outras provisões relevantes da Diretiva 1999/5/EC.
Español:
Este equipo cumple con los requisitos esenciales y otras provisiones relevantes de la
Directiva 1999/5/EC.
Svenska:
Denna utrustning uppfyller de väsentliga kraven och andra relevanta förordningar i Direktiv 1999/5/EC.
Norsk:
Dette utstyret er i samsvar med de grunnleggende krav og andre relevante bestemmelser
i EU-direktiv 1999/5/EF
lslenska:
Þetta taeki er samkvaemnt grunnkröfum og öðrum viðeigandi ákvaðum Tilskipunar 1999/
5/CE.
Corporate Headquarters
Datalogic S.p.A.
Via Candini, 2
40012 Lippo di Calderara di Reno
Bologna - Italy
Telephone: +39 051 3147011
Fax: +39 051 726562
www.mobile.datalogic.com
Datalogic Mobile, Inc.
1505 Westec Dr.
Eugene, OR 97402
Telephone: (541) 743-4800
Fax: (541) 743-4900
©2007 Datalogic Mobile, Inc.
R44-2576 (Rev X3a)
05/07

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : No
Encryption                      : Standard V2.3 (128-bit)
User Access                     : Print, Copy, Print high-res
Page Mode                       : UseOutlines
XMP Toolkit                     : 3.1-702
Producer                        : Acrobat Distiller 7.0.5 (Windows)
Create Date                     : 2007:05:14 14:24:51Z
Creator Tool                    : Adobe Illustrator CS3
Modify Date                     : 2008:01:24 21:12:55-08:00
Metadata Date                   : 2008:01:24 21:12:55-08:00
Thumbnail Width                 : 152
Thumbnail Height                : 256
Thumbnail Format                : JPEG
Thumbnail Image                 : (Binary data 10795 bytes, use -b option to extract)
Format                          : application/pdf
Title                           : untitled
Document ID                     : uuid:2cff8218-4377-4a69-b3f4-f3800a32e0c6
Instance ID                     : uuid:7a1b62ec-ccec-4830-a989-29698a781b85
N Pages                         : 1
Has Visible Transparency        : False
Has Visible Overprint           : False
Max Page Size W                 : 396.000000
Max Page Size H                 : 612.000000
Max Page Size Unit              : Points
Font Name                       : Verdana-Bold, Verdana
Font Family                     : Verdana, Verdana
Font Face                       : Bold, Regular
Font Type                       : Open Type, Open Type
Font Version                    : Version 2.40, Version 2.43
Font Composite                  : False, False
Font File Name                  : verdanab.TTF, verdana.TTF
Plate Names                     : Cyan, Magenta, Yellow, Black
Swatch Group Name               : Default Swatch Group
Swatch Group Type               : 0
Has XFA                         : No
Page Count                      : 56
Creator                         : Adobe Illustrator CS3
EXIF Metadata provided by EXIF.tools
FCC ID Filing: U4SPD

Navigation menu