Datalogic S r l 0018 Mobile Computer User Manual R3Integration Guide

Datalogic ADC S.r.l. Mobile Computer R3Integration Guide

Integration Guide

Download: Datalogic S r l 0018 Mobile Computer User Manual R3Integration Guide
Mirror Download [FCC.gov]Datalogic S r l 0018 Mobile Computer User Manual R3Integration Guide
Document ID937188
Application IDLdvY/0Lg0tPEv8xQh3KEkg==
Document DescriptionIntegration Guide
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize5.55kB (69380 bits)
Date Submitted2008-05-06 00:00:00
Date Available2008-05-06 00:00:00
Creation Date2008-03-25 09:32:25
Producing SoftwareGPL Ghostscript 8.15
Document Lastmod2008-03-25 09:32:25
Document TitleMicrosoft Word - R3Integration Guide.doc
Document CreatorPScript5.dll Version 5.2.2
Document Author: MDeGirolami

Rfid Engine R3 Integration Guide
R3Integration Guide.doc
Revision: 1.0
3/25/2008
Signature:
DATALOGIC PROPRIETARY INFORMATIONS
page 1 of 5
Rfid Engine R3 Test
Introduction .................................................................................................................................................................... 3
Block Diagram ................................................................................................................................................................ 3
Comunication Interfaces ................................................................................................................................................ 4
Flex Cable Length........................................................................................................................................................... 4
Mechanical installation .................................................................................................................................................. 4
Regulatory ....................................................................................................................................................................... 5
Caution.......................................................................................................................................................................... 5
Labeling requirements for the End Product .................................................................................................................. 5
Technical Features.......................................................................................................................................................... 5
R3Integration Guide.doc
page 2 of 5
DATALOGIC PROPRIETARY INFORMATIONS
Rfid Engine R3 Test
Introduction
The RF-3 RFID Engine is a dual technology module combining an undecoded laser scan engine
with a multi-standard high frequency RFID engine (requiring an ANSI C library for decoding).
Thus, it provides a single product allowing reading standard barcode symbologies and 13.56 MHz
tags and smart labels.
The Module is physically and electrically compatible with the Motorola SE1200 laser module thus
guaranteeing an easy integration within many Hand-Held barcode readers (Host). In addition,
it integrates an internal small antenna.
The RFID supports the following standards:
•
•
•
•
ISO14443A
ISO14443B
ISO15693
Philips I-Code 1
There are 4 versions available:
• Rfid only
• Rfid only + SE950 barcode reader
• Rfid only – With plastic frame for mounting on Datalogic DLBJET
• Rfid only + SE950 barcode reader – With plastic frame for mounting on Datalogic DLBJET
Block Diagram
3,3V
LDO
HOST
Flat cab.
Level
shifters
ARM7
uP
5,2V
Step Up
•
•
•
RF
modem
RF front
end
Level
shifters
Antenna
Scan
engine
Flat cab.: 10 poles flex cable.
Antenna: Integral 4 turns loop antenna
Scan engine: Optional SE950 Module from Motorola.
R3Integration Guide.doc
page 3 of 5
DATALOGIC PROPRIETARY INFORMATIONS
Rfid Engine R3 Test
Comunication Interfaces
The module can be connected to an host trough a 10 wires flex cable.
The pins are used in different ways based on the fact the host is using the module to read a barcode or an
RFID tag.
In both modes the SCAN_EN signal (pin 5) can be forced low to place the module in sleep state (low-power
mode) and to switch the interface to Barcode Mode.
The module can be switched from barcode mode to RFID mode simply sending a packet on the SPI
interface.
Pins 1 and 10 are used for test and configuration at the factory and should be left unconnected.
Pin #
10
RFID Mode
UART RX
VCC
MOSI
Clock
SCAN_EN
MISO
CS
GND
UART TX
Barcode Mode
UART RX
VCC
AIM
LASER_EN
SCAN_EN
DBP
SOS
GND
GND
UART TX
Please refer to the SE950 Module integration Guide for further details about the Barcode Interface.
Please use the Datalogic RF-3 communication library software to interface to the Module when in RFID
mode.
Flex Cable Length
The maximum allowed/tested flex cable length is 75 mm.
Mechanical installation
There are two types of contrains to take into account when installing the module. The first types relate to the
Barcode reader function: to perform according to the specifications the integrated SE950 scan engine
requires a laser beam window with specific size, orientation and materials. Please refer to the SE950
intergration guide for details on this matter.
The second type of requirement is about metal parts located near the RFID antenna. Such parts could modify
the antenna resonance frequency and lead to reduced antenna effectiveness. Please keep metallic parts as
far as possible from the antenna to prevent malfunctioning.
R3Integration Guide.doc
page 4 of 5
DATALOGIC PROPRIETARY INFORMATIONS
Rfid Engine R3 Test
Regulatory
FCC Statement
This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions:
(1) this device my not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired
operation.
Caution
Modifications or changes to this equipment without the expressed written approval of Datalogic Scanning
Group S.r.l. would void the authority to use the equipment.
Labeling requirements for the End Product
Any device incorporating this module must be labeled with the following informations:
Contains FCC ID: U4F0018
This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions:
(1) this device my not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired
operation.
Technical Features
Electical Features
Power Supply
Max. Input Current
Max. Stand-by current
Radio Features
RF Frequency
Max. SPI Clock Frequency
RFID reading distance
Environmental Features
Operating Temperature
Storage Temperature
Shock resistance
Physical Features
Mechanical dimensions
Weight
From 3,13 Vdc to 5,25 Vdc
600mA
500uA
13.56 Mhz
100 Kbit/s
Up to 10 cm depending on tag.
-20 a +60’C
-40 a +70 ’C
2000 g
39.5 x 20 x 28 mm
19g (with SE950)
R3Integration Guide.doc
page 5 of 5
DATALOGIC PROPRIETARY INFORMATIONS

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
Page Count                      : 5
Producer                        : GPL Ghostscript 8.15
Create Date                     : 2008:03:25 09:32:25
Modify Date                     : 2008:03:25 09:32:25
Title                           : Microsoft Word - R3Integration Guide.doc
Creator                         : PScript5.dll Version 5.2.2
Author                          : MDeGirolami
EXIF Metadata provided by EXIF.tools
FCC ID Filing: U4F0018

Navigation menu