Datalogic S r l JNGW JOYA TOUCH Basic - Multi-purpose device for retail User Manual 822002101

Datalogic ADC S.r.l. JOYA TOUCH Basic - Multi-purpose device for retail 822002101

Contents

User Manual_quick start guide rev3

Datalogic ADC S.r.l.Via S. Vitalino, 1340012 Lippo di Calderara di RenoBologna - ItalyTelephone: (+39) 051-3147011 Fax: (+39) 051-3147205©2016 Datalogic ADC S.r.l.An Unpublished Work - All rights reserved. No part of the contents of this documentation orthe procedures described therein may be reproduced or transmitted in any form or by anymeans without prior written permission of Datalogic ADC S.r.l. or its subsidiaries oraffiliates ("Datalogic" or “Datalogic ADC”). Owners of Datalogic products are hereby granteda non-exclusive, revocable license to reproduce and transmit this documentation for thepurchaser's own internal business purposes. Purchaser shall not remove or alter anyproprietary notices, including copyright notices, contained in this documentation and shallensure that all notices appear on any reproductions of the documentation.Should future revisions of this manual be published, you can acquire printed versions bycontacting your Datalogic representative. Electronic versions may either be downloadablefrom the Datalogic website (www.datalogic.com) or provided on appropriate media. If youvisit our website and would like to make comments or suggestions about this or otherDatalogic publications, please let us know via the "Contact Datalogic" page.DisclaimerDatalogic has taken reasonable measures to provide information in this manual that iscomplete and accurate, however, Datalogic reserves the right to change any specification atany time without prior notice.Datalogic and the Datalogic logo are registered trademarks of Datalogic S.p.A. in manycountries, including the U.S.A. and the E.U. JOYA TOUCH is a trademark of Datalogic ADC S.r.l. and the JOYA logo is a registeredtrademark of Datalogic ADC S.r.l. in the U.S.A. and the E.U.All other brand and product names may be trademarks of their respective owners.PatentsSee www.patents.datalogic.com for patent list.Reference DocumentationFor further information regarding JOYA TOUCH refer to the SDK Help on-line and to theJOYA TOUCH User’s Manual, downloadable from our website www.datalogic.com.Service and SupportDatalogic provides several services as well as technical support through its website. Pleasecheck our website at www.datalogic.com under “Support & Services”, then “Automatic DataCapture”, and click on the links indicated for further information including:• Downloads•Manuals for the latest versions of user manuals and product guides. •Software & Utilities for the latest firmware release for your product. You can also click on the following link for direct access to this section: www.datalogic.com/products_updates.•Service Program for warranty extensions and maintenance agreements.•Repair Centers for a list of authorised repair centers.•Technical Support Automatic Data Capture email form to contact our technicalsupport.Warranty Terms and ConditionsThe warranty period is 1 year for the device and 90 days for consumables (e.g. battery,power supply, cable etc.) from date of purchase at our company. Multi-Purpose Device for Retail Quick Start Guide822002101               (Rev. A)             Sept. 2016Out of the BoxThe JOYA TOUCH package contains: •JOYA TOUCH (device)• Rechargeable battery•Quick Start Guide•Safety & Regulatory AddendumRemove all the components from their packaging; check their integrityand compare them with all the packing documents.General ViewFront ViewBack ViewCAUTIONKeep the original packaging for use when sending products tothe technical assistance center. Damage caused by improperpackaging is not covered under the warranty.Touch Panel DisplayScan KeyLaser Safety LabelProduct LabelCold Boot ButtonTop ViewSide ViewResetting the JOYA TOUCHWarm BootA “warm boot” terminates an unresponsive application and clears theworking RAM, but preserves both the file system and the registry.To perform a warm boot, tap Start > Programs > Warm Boot.Cold BootA cold boot is a complete reset of the JOYA TOUCH in which allapplications are forcibly closed and RAM is completely cleared. You willlose any applications and data which are not stored in persistent flashmemory.To perform a cold boot, lightly press with a metallic clip inside the circlehole on the back for 10 seconds.Clean BootA clean boot is a complete restore to factory default and backup foldercontent erase of the JOYA TOUCH. You will loose any applications anddata. To perform a clean boot:1. Execute a cold boot while keeping pressed the Scan key.2. A pop-up will ask you to confirm, confirm by pressing and releasing the Scan key for three times, or wait for 3 seconds to cancel.Data Capture WindowPistol ModelsHandheld ModelsMicro USB PortPistol TriggerSee the Regulatory Addendumincluded with your product foradditional regulatory, safety andlegal information..©2016 Datalogic ADC S.r.l. • All rightsreserved. Datalogic and the Datalogic logo areregistered trademarks of Datalogic S.p.A.in many countries, including the U.S.A.and the E.U. JOYA TOUCH is a trademarkof Datalogic ADC S.r.l. and the JOYA logois a registered trademark of DatalogicADC S.r.l. in the U.S.A. and the E.U.www.datalogic.com
Battery InstallationTo install the battery pack, follow the steps below:1.2.3.4.NOTERequired torque of the screws is 35 cNm.Handheld Models Gun ModelsHandheld Models Gun ModelsHandheld Models Gun ModelsHandheld Models Gun ModelsCharging InstructionsThe battery pack is not initially fully charged. After installing the battery, charge it with the 3-slotcradle.There are two options to connect the cradle to the power supply: fast charge and standard charge.Fast ChargeThe fast charge connection allows to power one cradle with one power supply. Plug the power supply cable into the power connector on the back of the cradle as shown in the figurebelow:Standard ChargeThe standard charge connection allows to power two cradles with one power supply. To connect a second cradle use the JOYA TOUCH Cradle Power Jumper, available as optional accessory(P/N 91ACC0049).1. Connect the first cradle to the second cradle using the power jumper.2. Connect the power supply to the first cradle.Synchronize Your Device with the PCSet up Synchronization using Windows Mobile® Device CenterWindows Mobile® Device Center can be downloaded from Microsoft website www.microsoft.com. It isonly compatible with Windows Vista and Windows 7; if you run Windows XP or earlier, you have todownload Microsoft ActiveSync.You can establish a connection to your JOYA TOUCH through the USB. To establish a partnership between the JOYA TOUCH and a host PC, start Windows Mobile® DeviceCenter and follow the steps below:1. Select the "ENABLE DIRECT CONNECTION TO THE DESKTOP COMPUTER" from the JOYA TOUCH PC connection menu.2. Connect the JOYA TOUCH to the host PC. Windows Mobile® Device Center configures itself and then opens.3. On the license agreement screen, click Accept.4. On the Windows Mobile Device Center’s Home screen, click Set up your device.5. Select the information types that you want to synchronize, then click Next.6. Enter a device name and click Set Up.When you finish the setup wizard, Windows Mobile Device Center synchronizes the deviceautomatically.NOTECharge the battery for a minumum of 4 hours.NOTEFor further information on the JOYA TOUCH 3-Slot Cradle, refer to the JOYA TOUCH 3-SlotCradle Quick Start Guide, included in the cradle’s box, and to the JOYA TOUCH 3-Slot CradleInstallation Guide, downloadable from our website www.datalogic.com.Visible Display High DensityScanning and ImagingImager Data CaptureRelative Size and Location of Aiming System PatternRadio Technologies and Frequency BandsJOYA TOUCH incorporates the following radio technologies and supports the correspondingfrequencies, as specified below for Plus and Basic Variants:LINEAR BARCODE 2D MATRIX SYMBOLRadio Technology Frequency BandsPlus VariantsFCC ID: U4GJNGWBIC: 3862E-JNGWBBasic VariantsFCC ID: U4GJNGWIC: 3862E-JNGWWLAN IEEE 802.11a/b/g/n, 20MHz channels bandwidth (HT-20)2.4GHz Frequency Bands: 2.412 – 2.472 MHz (EU / Japan) 2.412 – 2.462 MHz (USA) 5GHz Frequency Bands: 5.180 – 5.240 MHz 5.260 – 5.320 MHz 5.500 – 5.700 MHz 5.735 – 5.825 MHz (USA)XXBluetooth® V4.0 – Dual-Mode  2402-2480Mhz  XWireless Charging (Receiver) 130kHz X X

Navigation menu