Datalogic 0003 OM-GRYPHON Series Radio Cradle User Manual a OMGryphon Master

Datalogic SpA OM-GRYPHON Series Radio Cradle a OMGryphon Master

manual

OM-GRYPHON SERIESRADIO CRADLEQuick ReferenceInstallazione RapidaManuel d'Installation RapideSchnellinstallationManual De Instalación Rápida
DATALOGIC S.p.A.,Via Candini, 240012 - Lippo di CalderaraBologna - Italydichiara chedeclares that thedéclare que lebescheinigt, daß das Gerätdeclare que elOM-GRYPHON, Base Chargere tutti i suoi modelliand all its modelset tous ses modèlesund seine modelley todos sus modelossono conformi alle Direttive del Consiglio Europeo sottoelencate:are in conformity with the requirements of the European Council Directives listed below:sont conformes aux spécifications des Directives de l'Union Européenne ci-dessous:den nachstehenden angeführten Direktiven des Europäischen Rats entsprechen:cumple con los requisitos de las Directivas del Consejo Europeo, según la lista siguiente:1999/5/EEC R&TTEQuesta dichiarazione è basata sulla conformità dei prodotti alle norme seguenti:This declaration is based upon compliance of the products to the following standards:Cette déclaration repose sur la conformité des produits aux normes suivantes:Diese Erklärung basiert darauf, daß das Produkt den folgenden Normen entspricht:Esta declaración se basa en el cumplimiento de los productos con las siguientes normas:EN 60950, October 1996:SAFETY OF INFORMATION TECHNOLOGY EQUIPMENT,  INCLUDINGELECTRICAL BUSINESS EQUIPMENTETS 300 683, June 1997:RADIO  EQUIPMENT AND SYSTEMS  (RES); ELECTROMAGNETICCOMPATIBILITY  (EMC)  STANDARD FOR SHORT  RANGE  DEVICES(SRD)  OPERATING ON FREQUENCIES BETWEEN 9 KHZ AND 25GHZETS 300 220-1, November 1997:ELECTROMAGNETIC COMPATIBILITY AND RADIO SPECTRUMMATTERS  (ERM); SHORT  RANGE  DEVICES; TECHNICALCHARACTERISTICS AND TEST METHODS FOR RADIO EQUIPMENT TOBE USED IN THE 25 MHZ TO 1000 MHZ FREQUENCY RANGE WITHPOWER LEVELS RANGING UP TO 500 MW; PART  1: PARAMETERSINTENDED FOR REGULATORY PURPOSESLippo di Calderara, 13.03.2001Ruggero CacioppoQuality Assurance SupervisorDatalogic reserves the right to make modifications and improvements without prior notification.Product names mentioned herein are for identification purposes only and may be trademarks and orregistered trademarks of their respective companies.© - 2001 Datalogic S.p.A.PRELIMINARY
iiiCONTENTSServices Available at Our Website .................................................................2Using OM-GRYPHON Radio Cradle...............................................................3System Connections ......................................................................................4Connecting / Disconnecting the OM-GRYPHON  Interface Cable.............................4RS232 Connection .................................................................................5Pen Connection......................................................................................5Wedge Connection.................................................................................6OM-GRYPHON Configuration ........................................................................7Wedge Keyboard Nationality........................................................................11Operating Test .............................................................................................12OM-GRYPHON Default Configuration ..........................................................13Information to the Users ...............................................................................13Warranty ......................................................................................................14Technical Features.......................................................................................14INDICEDisponibili nel Nostro Sito Web ....................................................................16Base Radio OM-GRYPHON – Descrizione e Uso ........................................17Sistema Radio - Collegamenti ......................................................................18Cavo Interfaccia – Collegamento e Scollegamento...............................................18RS232 ..................................................................................................19Pen ......................................................................................................19Wedge..................................................................................................20Configurazione dell’OM-GRYPHON .............................................................21Nazionalità della Tastiera .............................................................................25Test di Funzionamento.................................................................................26OM-GRYPHON - Configurazione Di Default.................................................27Avvertenze ...................................................................................................27Garanzia ......................................................................................................28Caratteristiche Tecniche...............................................................................28SOMMAIREDisponibles dans Notre Site Web .................................................................30Utilisation de la Base Radio OM-GRYPHON ................................................31Connexion Systeme .....................................................................................32Connexion / Deconnexion du Cable d'Interface pour OM-GRYPHON...........32Connexion RS232 ................................................................................33Emulation Crayon.................................................................................33Connexion Interclavier..........................................................................34Configuration OM-GRYPHON ......................................................................35Nationalite du Clavier ...................................................................................39Test de Foctionnement.................................................................................40OM-GRYPHON - Configuration par Defaut...................................................41Precautions ..................................................................................................41Garantie .......................................................................................................42Caracteristiques Techniques ........................................................................42
ivINHALTSVERZEICHNISVerfügbar auf Unserem Web Site.................................................................44Funktion der OM-GRYPHON Funk - Und Ladestation ..................................45Systemanschluß...........................................................................................46Ein- und Ausstecken der Anschlußkabel ......................................................46RS232 - Schnittstelle............................................................................47Lesestiftschnittstelle .............................................................................47Tastaturschnittstelle .............................................................................48OM-GRYPHON Konfiguration ......................................................................49Tastaturnationalität.......................................................................................53Codes für Testzwecke..................................................................................54OM-GRYPHON Grundeinstellung ................................................................55Hinweise ......................................................................................................55Gewährleistung ............................................................................................56Technische Daten ........................................................................................56INDICEServicios Disponibles en Nuestras Web Site................................................58Utilización de la Base Radio OM-GRYPHON ...............................................59Conexión del Sistema ..................................................................................60Conexión / Desconexión del Cable de Interfazpara OM-GRYPHON ....................................................................................60Conexión RS232 ..................................................................................61Emulación Lápiz...................................................................................61Emulación Teclado...............................................................................62Configuración OM-GRYPHON .....................................................................63Nacionalidad del Teclado .............................................................................67Test Operativo..............................................................................................68OM-GRYPHON - Configuración Predefinida ................................................69Advertencias ................................................................................................69Garantia .......................................................................................................70Características Técnicas ..............................................................................70
OM-GRYPHONRADIO CRADLEQuick Reference
English2SERVICES AVAILABLE AT OUR WEB SITE:By completing the electronic form at our website,www.datalogic.com/hhd/gryphon_utilities.htm, you have free access todownload the following items:• WinSetPlus™WinSetPlus™ is a Windows-based utility program which allows deviceconfiguration using a PC. It provides RS232 interface configuration aswell as configuration barcode printing.• Loader:The Loader utility program is necessary to load the application software(upgrades) onto your reader.• Software Upgrades:Future software upgrades allow  your reader to be updated with thelatest improvements.These items are also available from your local Datalogic distributor.
English3USING OM-GRYPHON RADIO CRADLEThe OM-GRYPHON cradle, paired with one Gryphon™ series reader, buildsa Cordless Reading System for the collection, decoding and transmission ofbarcoded data.It can be connected to a Host PC through an RS232, Wedge or Penemulation cable and is suited for a single-cradle layout.Once it is powered, the yellow LED goes on. It will blink, only when the cradlereceives data from the gun. The red LED indicates the battery is charging.Once the battery is charged, the green LED on the cradle goes on.To setup your OM-GRYPHON cradle you must:1.  Make all system connections.2.  Configure the OM-GRYPHON cradle.Power on / Data(yellow LED)Reconditioning batterybuttonCharging(red LED)Charge completed(green LED)
English4SYSTEM CONNECTIONSCAUTIONConnections should always be made with power OFF!You can connect the OM-GRYPHON cradle to the Host through the dedicatedconnector, using the cable corresponding to the desired interface type.CONNECTING / DISCONNECTING THE OM-GRYPHONINTERFACE CABLEThe OM-GRYPHON can be connected to a Host by means of an RS232,Wedge or Pen emulation cable which must be simply plugged into the Hostconnector, placed on the base of the cradle. In addition the cradle must beconnected to an external power supply, see the figure below.Figure 1 – OM-GRYPHON - Bottom viewTo disconnect the cable, insert a paper clip or other similar object into the holecorresponding to the Host connector on the body of the cradle. Push down onthe clip while unplugging the cable. Refer to the following figure:Figure 2 – OM-GRYPHON - Disconnecting the cable.Power SupplyHost InterfaceCable
English5RS232 CONNECTIONPEN CONNECTION
English6WEDGE CONNECTION
English7OM-GRYPHON CONFIGURATIONThe OM-GRYPHON configuration can be performed in two ways: either byreading configuration barcodes with the Gryphon™ reader or by sendingconfiguration strings from the Host via the RS232 interface.Once you have performed system connection and Gryphon™ readerconfiguration, you can configure the OM-GRYPHON cradle. Apply power tothe OM-GRYPHON.For the Gryphon™ configuration refer to the “Gryphon™ Quick Reference”.To configure the OM-GRYPHON using the Gryphon™ reader (the one paired tothe cradle with the Bind command), follow the given sequence and theinstructions.Read the OM-GRYPHON restore default code:1.Restore OM-GRYPHON defaulti39Rki39Rki39RkAmong the following interface selection codes, read only the codethat suits your application:2.RS232 Interfacei$1ki$1ki$1kPEN Interfacei$1#ki$1#ki$1#k
English8WEDGE InterfaceIBM AT or PS/2 PCsi$1Bki$1Bki$1BkIBM XTi$1Wki$1Wki$1WkPC Notebooki$1eki$1eki$1ekIBM SURE1i$1ki$1ki$1kIBM Terminal 3153i$1^ki$1^ki$1^k
English9WEDGE Interface (continued)IBM TerminalsIBM Terminals 31xx, 32xx, 34xx, 37xx:read the correct Key Transmission code:make-only keyboardi$1Pki$1Pki$1Pkmake-break keyboardi$1Iki$1Iki$1Ikread the Keyboard Type code, if necessary:advanced keyboardi',fki',fki',fktypewriter keyboardi',aki',aki',akThe following interface selection allows barcodes sent to the PC to beinterpreted correctly independently from the Keyboard Nationality used.You do not need to make a Keyboard Nationality selection.(default = Num Lock Unchanged)Make sure the Num Lock key on your keyboard is ON.IBM AT - ALT modei$1ki$1ki$1kPC Notebook - ALT modei$1ki$1ki$1k
English10WEDGE Interface (continued)Wyse TerminalsANSI Keyboardi$1ki$1ki$1kPC Keyboardi$1Hki$1Hki$1HkASCII Keyboardi$1Oki$1Oki$1OkVT220 style Keyboardi$1dki$1dki$1dkDigital TerminalsVT2xx/VT3xx/VT4xxi$1Vki$1Vki$1VkAPPLEAPPLE ADB Busi$1]ki$1]ki$1]k
English11WEDGE KEYBOARD NATIONALITYIf you selected the Wedge interface, you should also read among thefollowing codes the one that matches your Keyboard Nationality:Englishi'+ki'+ki'+kDeutschi'+ki'+ki'+kSvenskti'+ki'+ki'+kFrançaisi'+gki'+gki'+gkItalianoi'+bki'+bki'+bkUSAi'+]ki'+]ki'+]kEspañoli'+ki'+ki'+kBelgei'+ki'+ki'+k
English12OPERATING TESTRead the TEST codes belowEAN-8  1234  5670   EAN-131  234567 000992    Code 39 (Normal)17162Code 128testInterleaved 2 of 50123456784PDF417DATALOGIC PDF417 Test CodeYOUR SYSTEM IS NOW READY TO READ BARCODES ACCORDING TOTHE DEFAULT CONFIGURATION AND TO SEND THE DATA TO THEHOST.
English13OM-GRYPHON DEFAULT CONFIGURATIONRS232 DEFAULT SETTINGS9600 baud, parity disabled, 8 data bits, 1 stop bit, handshaking disabled,delay disabled, 5 sec. rx timeoutPEN DEFAULT SETTINGSoutput level normal, idle level normal, minimum output pulse 600µs, overflowmediumWEDGE DEFAULT SETTINGSUSA keyboard, caps lock off, num lock off, delays disabledCRADLE OPERATING PARAMETERSNo header, terminator: RS232 = CR-LF; WEDGE = CRINFORMATION TO THE USERSDC supply voltage in the range 9 to 28 V DC, intended to be powered by aClass 2 power unit with a cable length <3 m.This device must be opened by qualified personnel only.Modifications or changes to this equipment without the expressed writtenapproval of Datalogic could void the authority to use the equipment.This device complies with PART 15 of the FCC Rules. Operation is subjectto the following two conditions: (1) This device may not cause harmfulinterference, and (2) this device must accept any interference received,including interference which may cause undesired operation.This equipment has been tested and found to comply with the limits for a Class B digitaldevice, pursuant to part 15 of the FCC Rules. These limits are designed to providereasonable protection against harmful interference in a residential installation. Thisequipment generates, uses and can radiate radio frequency energy and, if not installedand used in accordance with the instructions, may cause harmful interference to radiocommunications. However, there is no guarantee that interference will not occur in aparticular installation. If this equipment does cause harmful interference to radio ortelevision reception, which can be determined by turning the equipment off and on, theuser is encouraged to try to correct the interference by one or more of the followingmeasures:- Reorient or relocate the receiving antenna.- Increase the separation between the equipment and receiver.- Connect the equipment into an outlet on a circuit different from that to which thereceiver is connected.- Consult the dealer or an experienced radio/TV technician for help.Contact the competent authority responsible for the management of radiofrequency devices of your country to verify the eventual necessity of a userlicense.Refer to the web site http://europa.eu.int/comm/enterprise/rtte/spectr.htm  forfurther information.
English14WARRANTYDatalogic warranties this product against defects in workmanship andmaterials, for a period of 24 months from the date of shipment, provided thatthe product is operated under normal and proper conditions.Datalogic has the faculty to repair or replace the product, these provisions donot prolong the original warranty term.The warranty does not apply to any product that has been subject to misuse,accidental damage, unauthorized repair or tampering.TECHNICAL FEATURESOM-GRYPHONElectrical FeaturesSupply voltage 9..28 VdcPower consumption max. 8 W (charging) *Indicators Battery charging (red)Charge completed (green)Power / Data (yellow)Time of recharge NiMh / NiCd batteries: 3 hours maxRadio Features European Models USA MODELSWorking Frequency 433.92 Mhz 910 MhzBit rate 19200 baud 36800 baudEffective Radiated Power <10 mW <1 mWRange (in open air) 30 m. 15 m.RF Modulation FSKMax number of devices in the samereading area 2000Environmental FeaturesWorking temperature 0 to +40 °CStorage temperature -20 to +70 °CHumidity 90 % non condensingProtection class IP30Mechanical FeaturesWeight about 250 g.Dimensions 208 x 107 x 55.5 mmMaterial ABS* Having a switching regulator inside, the OM-GRYPHON draws the samepower, regardless of the supply voltage, i.e. as the input voltage increasesthe current drawn decreases.