Datalogic 0015 RADIO STAR-MODULE 910 User Manual OM Dragon Eng

Datalogic SpA RADIO STAR-MODULE 910 OM Dragon Eng

OM Dragon User Guide

Download: Datalogic 0015 RADIO STAR-MODULE 910 User Manual OM Dragon Eng
Mirror Download [FCC.gov]Datalogic 0015 RADIO STAR-MODULE 910 User Manual OM Dragon Eng
Document ID613085
Application IDSuwT2SnLiKIbCAdaUpYfbw==
Document DescriptionOM Dragon User Guide
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize146.11kB (1826353 bits)
Date Submitted2005-12-20 00:00:00
Date Available2005-12-20 00:00:00
Creation Date2005-11-16 17:49:43
Producing SoftwareAcrobat Distiller 6.0.1 (Windows)
Document Lastmod2005-11-16 17:49:43
Document TitleMicrosoft Word - OM-Dragon_Eng.doc
Document CreatorPScript5.dll Version 5.2
Document Author: ESchino

OM-DRAGON™ SERIES
QUICK REFERENCE
DATALOGIC S.p.A.
Via Candini 2
40012 - Lippo di Calderara di Reno
Bologna - Italy
OM-DRAGON™
Ed.: 11/2005
ALL RIGHTS RESERVED
Datalogic reserves the right to make modifications and improvements without prior
notification.
Datalogic shall not be liable for technical or editorial errors or omissions contained herein,
nor for incidental or consequential damages resulting from the use of this material.
Product names mentioned herein are for identification purposes only and may be
trademarks and or registered trademarks of their respective companies.
© Datalogic S.p.A. 2002-2005
Preliminary
CONTENTS
Updates and Language Availability.....................................................................iv
Using OM-DRAGON™ Radio Cradle.................................................................. 1
Installation ........................................................................................................... 2
System Connections ........................................................................................... 5
Connecting and Disconnecting the OM-DRAGON™ Interface Cable................. 5
OM-DRAGON™ Configuration ........................................................................... 7
Wedge Keyboard Nationality............................................................................. 11
Operating Test .................................................................................................. 13
OM-DRAGON™ Default Configuration ............................................................. 14
Technical Features............................................................................................ 15
Warranty............................................................................................................ 16
Services And Support ....................................................................................... 16
Compliance ....................................................................................................... 16
iii
UPDATES AND LANGUAGE AVAILABILITY
UK/US
The latest drivers and documentation updates for this product are available on
Internet.
Log on to : www.datalogic.com
Su Internet sono disponibili le versioni aggiornate di driver e documentazione di
questo prodotto. Questo manuale è disponibile anche nella versione italiana.
Collegarsi a : www.datalogic.com
Les versions mises à jour de drivers et documentation de ce produit sont
disponibles sur Internet. Ce manuel est aussi disponible en version française.
Cliquez sur : www.datalogic.com
Im Internet finden Sie die aktuellsten Versionen der Treiber und Dokumentation
von diesem Produkt. Die deutschsprachige Version dieses Handbuches ist
auch verfügbar.
Adresse : www.datalogic.com
En Internet están disponibles las versiones actualizadas de los drivers y
documentación de este producto. También está disponible la versión en
español de este manual.
Dirección Internet : www.datalogic.com
iv
OM-DRAGON™
USING OM-DRAGON™ RADIO CRADLE
The OM-DRAGON™ cradle, paired with one or more DRAGON™ M series
laser guns, builds a Cordless Reading System for the collection, decoding and
transmission of barcoded data.
It can be connected to a Host PC through an RS232, Wedge or Pen cable and
is suited for both single-cradle and multi-cradle layouts.
It can also be connected to a C-Box and therefore integrated into a fixed
scanner application.
To setup your OM-DRAGON™ cradle you must:
1.
Physically install the cradle.
2.
Make all system connections.
3.
Configure the OM-DRAGON™ cradle.
DATALOGIC
INSTALLATION
The OM-DRAGON™ can be mounted for portable or fixed desktop usage, or it
can be fixed to a wall. In all cases, the mounting base must be used.
The OM-DRAGON™ package contains the following:
OM-DRAGON™
This Quick Reference Manual
2 adhesive strips
4 rubber feet
3 screws
3 threaded dowels
1 alignment plate
1 Antenna
Figure 1 - OM-DRAGON™ Mounting Base bottom view
PORTABLE DESKTOP USE
For desktop use, the OM-DRAGON™ is already correctly positioned on the
base.
1.
2.
3.
Referring to Figure 1, carefully clean the rubber feet seat of the base to
remove any impurities that could reduce adhesion.
Remove the protective plastic from the rubber feet and stick them onto the
bottom surface of the base.
Insert the antenna in the appropriate hole on the body of the cradle and
screw it clockwise until tight.
OM-DRAGON™
FIXED DESKTOP USE
For fixed desktop installation use the adhesive strips referring to Figure 1.
1.
2.
3.
4.
5.
If you are installing several cradles and you desire to align them, you can
use the alignment plate (see Alignment Plate Installation), otherwise
continue with step 2.
Carefully clean the adhesive strip seat of the base to remove any
impurities that could reduce adhesion.
Remove the protective plastic from one side of the adhesive strips and
stick them onto the base surface.
Remove the plastic from the other side of the strips and affix the base to
the table.
Insert the antenna in the appropriate hole on the body of the cradle and
screw it clockwise until tight.
WALL MOUNTING
Since the OM-DRAGON™ is mounted on its base when delivered, before
performing the following operation, unscrew the fixing screw and detach the
cradle from the base by holding the base tight and pushing the cradle
backwards.
Figure 2- OM-DRAGON™ top view
DATALOGIC
For wall mounting, the cradle is positioned as shown in Figure 3:
Figure 3 - OM-DRAGON™ Base
1.
2.
3.
4.
5.
6.
7.
8.
If you are installing several cradles and you desire to align them, you can use
the alignment plate (see Alignment Plate Installation), otherwise continue
with step 2.
Using the mounting holes on the base as a pattern mark the wall where
you desire to mount the OM-DRAGON™.
Drill three appropriate size holes.
Insert the threaded dowels into the holes.
Position the base on the wall and affix it by means of the three screws.
Reattach the cradle body by sliding it along the mounting tabs until aligned.
Fix the cradle to the base by means of the fixing screw. (See Figure 2).
Insert the antenna in the appropriate hole on the body of the cradle and
screw it clockwise until tight.
ALIGNMENT PLATE
1.
2.
Referring to Figure 1 and Figure 4, snap the Alignment Plate into the holes
provided on the base so that the plate remains extended from the side of
the base.
Snap the next base onto the remaining pins of the Alignment Plate.
Figure 4 - Alignment Plate
OM-DRAGON™
SYSTEM CONNECTIONS
Connections should always be made with power off!
CAUTION
You can connect the OM-DRAGON™ cradle to the Host through the dedicated
connector, using the cable corresponding to the desired interface type.
CONNECTING AND DISCONNECTING
OM-DRAGON™ INTERFACE CABLE
THE
The OM-DRAGON™ can be connected to a Host by means of an RS232, Wedge
or Pen cable which must be simply plugged into the Host connector, visible on the
rear panel of the cradle.
To disconnect the cable, insert a paper clip or other similar object into the hole
corresponding to the Host connector on the body of the cradle. Push down on the
clip while unplugging the cable. Refer to the following figure:
Power
Multi-standard interface
RS232, WEDGE, or PEN
Emulation to Host
Figure 5 – Connecting/Disconnecting the cable.
DATALOGIC
RS232 CONNECTION
WEDGE CONNECTION
PEN CONNECTION
OM-DRAGON™
C-BOX CONNECTION
OM-DRAGON™ CONFIGURATION
The OM-DRAGON™ configuration can be performed in three ways: by using
the DL Sm@rtSet software configuration program, by sending configuration
strings from the Host PC via the RS232 interface or by reading configuration
barcodes with the DRAGON™ M reader.
DL SM@RTSET
DL Sm@rtSet is a Windows-based utility program providing a quick and userfriendly configuration method via the RS232 interface.
It also allows upgrading the software of the connected device (see the DL
Sm@rtSet User's Manual for more details).
SERIAL CONFIGURATION
By connecting the OM-DRAGON™ to a PC through an RS232 interface cable it
is possible to send configuration strings from the PC to OM-DRAGON™.
CONFIGURATION BARCODES
Once you have performed system connection and DRAGON™ M reader
configuration, you can configure the OM-DRAGON™ cradle by reading
configuration barcodes. Apply power to the OM-DRAGON™.
For the DRAGON™ M configuration refer to the “DRAGON™ M Quick
Reference”.
To configure the OM-DRAGON™ using the DRAGON™ M reader (the one paired
to the cradle with the Bind command), follow the given sequence and the
instructions.
DATALOGIC
1.
Read the OM-DRAGON™ restore default code, then read the interface
selection code for your application:
RESTORE OM-DRAGON™ DEFAULT
Ì$+RX0$-qÎ
2.
Among the following interface selection codes, read only the code that
suits your application:
RS232 INTERFACE
Ì$+CP0$-$Î
PEN INTERFACE
Ì$+CP6$-BÎ
WEDGE INTERFACE
IBM AT or PS/2 PCs
Ì$+CP500$-aÎ
IBM XT
Ì$+CP503$-vÎ
PC Notebook
Ì$+CP505$-ÈÎ
IBM SURE1
Ì$+CP506$-$Î
IBM Terminal 3153
Ì$+CP504$-}Î
OM-DRAGON™
WEDGE INTERFACE (CONTINUED)
IBM Terminals 31xx, 32xx, 34xx, 37xx:
To select the interface for these IBM Terminals, read the correct key
transmission code. Select the keyboard type if necessary (default = advanced
keyboard).
KEY TRANSMISSION MODE
make-only keyboard
Ì$+CP502$-oÎ
make-break keyboard
Ì$+CP501$-hÎ
KEYBOARD TYPE
advanced keyboard
Ì$+FK1$-ÉÎ
typewriter keyboard
Ì$+FK0$-ÄÎ
ALT MODE
The following interface selection allows barcodes sent to the PC to be
interpreted correctly independently from the Keyboard Nationality used. You
do not need to make a Keyboard Nationality selection.
(default = Num Lock Unchanged)
Make sure the Num Lock key on your keyboard is ON.
IBM AT - ALT mode
Ì$+CP507$-+Î
PC Notebook - ALT mode
Ì$+CP508$-2Î
DATALOGIC
WEDGE INTERFACE (CONTINUED)
WYSE TERMINALS
ANSI Keyboard
Ì$+CP509$-9Î
PC Keyboard
Ì$+CP510$-gÎ
ASCII Keyboard
Ì$+CP511$-nÎ
VT220 style Keyboard
Ì$+CP514$-ÇÎ
DIGITAL TERMINALS
VT2xx/VT3xx/VT4xx
Ì$+CP512$-uÎ
APPLE
APPLE ADB Bus
Ì$+CP513$-|Î
10
OM-DRAGON™
WEDGE KEYBOARD NATIONALITY
If you selected the Wedge interface, you should also read among the following
codes the one that matches your Keyboard Nationality:
Belge
Ì$+FJ7$-8Î
Deutsch
Ì$+FJ3$-$Î
English
Ì$+FJ4$-)Î
Español
Ì$+FJ6$-3Î
Français
Ì$+FJ2$-ÊÎ
Italiano
Ì$+FJ1$-ÅÎ
Svenskt
Ì$+FJ5$-.Î
USA
Ì$+FJ0$-|Î
11
DATALOGIC
The following Keyboard Nationality selections are only valid for IBM AT
compatible PCs:
Japanese
Ì$+FJ8$-=Î
Russian (Latin)
Ì$+FJ9$-BÎ
Russian (Cyrillic)
Ì$+FJA$-jÎ
Hungarian
Ì$+FJB$-oÎ
Yugoslavian
Ì$+FJC$-tÎ
Romanian
Ì$+FJD$-yÎ
Czechoslovakian
Ì$+FJE$-~Î
12
OM-DRAGON™
OPERATING TEST
Read the TEST codes below.
EAN-8
1234 5670
EAN-13
1 234567 000992
Code 39 (Normal)
Code 128
Interleaved 2 of 5
0123456784
PDF417
DATALOGIC PDF417 Test Code
YOUR SYSTEM IS NOW READY TO READ CODES AND TO SEND THE
DATA TO THE HOST.
To change the defaults refer to the "Dragon™ Reference Manual", part number
90ACC1855, or to the DL Sm@rtSet™ Configuration program, both
downloadable from the website.
13
DATALOGIC
OM-DRAGON™ DEFAULT CONFIGURATION
RS232 DEFAULT SETTINGS
9600 baud, parity disabled, 8 data bits, 1 stop bit, handshaking disabled,
ack/nack protocol disabled, FIFO enabled, delay disabled, 5 sec. rx timeout
WEDGE DEFAULT SETTINGS
USA keyboard, Caps Lock Auto-Recognition enabled, num lock unchanged,
inter-character and intercode delay disabled, control character emulation =
Ctrl+Shift+key
PEN DEFAULT SETTINGS
Interpret operating mode, conversion to code 39 enabled, output level normal, idle
level normal, minimum output pulse 600µs, overflow medium, interblock delay
disabled
DATA FORMAT
no header, terminator: RS232 = CR-LF; WEDGE = CR, gun and cradle address
stamping and address stamping delimiter disabled
RADIO PARAMETERS
Battery Type: Auto-detect
NETWORK PARAMETERS
RS485 network disabled
14
OM-DRAGON™
TECHNICAL FEATURES
OM-DRAGON™
Electrical Features
Supply voltage
Power consumption
Indicators
Time of recharge
Radio Features
9..28 Vdc
max. 8 W (charging) *
Charger on LED (red)
Charge completed LED (green)
Power / Data LED (yellow)
NiMh / NiCd batteries: 2 hours
European Models
USA Models
Working Frequency
433.92 MHz
910 MHz
Bit rate
19200 baud
36800 baud
50 m
30 m
OM-DRAGON™
STARGATE™
32
255
Range (in open air)
System Configuration
Max number of devices per base
station
Max number of devices in the
same reading area
Max number of base stations in
network
2000
16 (including cradle Master)
Environmental Features
Working temperature
-10° to +40 °C / +14° to +104 °F
Storage temperature
-20° to +60 °C / -4° to +140 °F
Humidity
90 % non condensing
Protection
IP40
Mechanical Features
Weight with mounting support
about 600 g. / 21.12 oz
Dimensions (without antenna)
185 x 115 x 104 mm / 7.2 x 4.5 x 4 in
Material
ABS
Having a switching regulator inside, the OM-DRAGON™ draws the same
power, regardless of the supply voltage. i.e. as the input voltage increases
the current drawn decreases.
NOTE
After many recharging cycles NiMh and NiCd batteries may
tend to lose their operating autonomy.
To limit this effect avoid inserting the DRAGON™ M into the
OM-DRAGON™ cradle frequently. This condition can be
overcome by inserting the laser reader into the
OM-DRAGON™ cradle and pressing the "battery
reconditioning" button (see DRAGON™ M Series Quick
Reference Manual).
15
DATALOGIC
WARRANTY
Datalogic warranties this product against defects in workmanship and materials,
for a period of 24 months from the date of shipment, provided that the product is
operated under normal and proper conditions.
Datalogic has the faculty to repair or replace the product, these provisions do
not prolong the original warranty term. The warranty does not apply to any
product that has been subject to misuse, accidental damage, unauthorized
repair or tampering.
SERVICES AND SUPPORT
Datalogic provides several services as well as technical support through its
website. Log on to www.datalogic.com and click on the links indicated for
further information including:
•
PRODUCTS
Search through the links to arrive at your product page where you can
download specific Manuals and Software & Utilities including:
- DL Sm@rtSet™ a Windows-based utility program which allows device
configuration using a PC. It provides RS232 interface configuration as
well as configuration barcode printing.
•
SERVICES & SUPPORT
- Datalogic Services
Agreements
Warranty
Extensions
and
Maintenance
- Authorised Repair Centres
•
CONTACT US
E-mail form and listing of Datalogic Subsidiaries
COMPLIANCE
POWER SUPPLY
This device is intended to be supplied by a UL Listed or CSA Certified Direct
Plug-in Power Unit marked "Class 2" output rated 9-28 V DC, minimum 0.8 A
and having a cable length <3 m.
This device must be opened by qualified personnel only.
16
OM-DRAGON™
FCC COMPLIANCE
Modifications or changes to this equipment without the expressed written
approval of Datalogic could void the authority to use the equipment.
This device complies with PART 15 of the FCC Rules. Operation is subject to
the following two conditions: (1) This device may not cause harmful
interference, and (2) this device must accept any interference received,
including interference which may cause undesired operation.
This device contains FCC ID OMJ0015.
This equipment has been tested and found to comply with the limits for a Class
B digital device, pursuant to part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and
on, the user is encouraged to try to correct the interference by one or more of
the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which
the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
RADIO COMPLIANCE
Contact the competent authority responsible for the management of radio
frequency devices of your country to verify the eventual necessity of a user
license.
Refer to the web site http://europa.eu.int/comm/enterprise/rtte/spectr.htm for
further information.
WEEE COMPLIANCE
17
DATALOGIC S.p.A.,
Via Candini, 2
40012 - Lippo di Calderara
Bologna - Italy
05
dichiara che
declares that the
déclare que le
bescheinigt, daß das Gerät
declare que el
OM-DRAGON, RF Base charger
e tutti i suoi modelli
and all its models
et tous ses modèles
und seine modelle
y todos sus modelos
sono conformi alla Direttiva del Consiglio Europeo sottoelencata:
are in conformity with the requirements of the European Council Directive listed below:
sont conformes aux spécifications de la Directive de l'Union Européenne ci-dessous:
der nachstehenden angeführten Direktive des Europäischen Rats entsprechen:
cumple con los requisitos de la Directiva del Consejo Europeo, según la lista siguiente:
1999/5/EEC R&TTE
Questa dichiarazione è basata sulla conformità dei prodotti alle norme seguenti:
This declaration is based upon compliance of the products to the following standards:
Cette déclaration repose sur la conformité des produits aux normes suivantes:
Diese Erklärung basiert darauf, daß das Produkt den folgenden Normen entspricht:
Esta declaración se basa en el cumplimiento de los productos con las siguientes normas:
ETSI EN 301 489-3 v.1.4.1, AUGUST 2002:
ELECTROMAGNETIC COMPATIBILITY AND RADIO SPECTRUM
MATTERS (ERM); ELECTROMAGNETIC COMPATIBILITY (EMC)
STANDARD FOR RADIO EQUIPMENT AND SERVICES; PART 3:
SPECIFIC CONDITIONS FOR SHORT-RANGE DEVICES (SRD)
OPERATING ON FREQUENCIES BETWEEN 9 KHZ AND 40 GHZ
ETSI EN 300 220 v.1.1.1, SEPTEMBER 2004: ELECTROMAGNETIC COMPATIBILITY AND RADIO SPECTRUM
MATTERS (ERM); SHORT RANGE DEVICES (SRD); RADIO
EQUIPMENT TO BE USED IN THE 25 MHZ TO 1000 MHZ
FREQUENCY RANGE WITH POWER LEVELS RANGING UP TO 500
MW; PART 3: HARMONIZED EN COVERING ESSENTIAL
REQUIREMENTS UNDER ARTICLE 3.2 OF THE R&TTE DIRECTIVE
EN 60950-1, December 2001:
INFORMATION TECHNOLOGY EQUIPMENT – SAFETY –
PART 1: GENERAL REQUIREMENTS
Lippo di Calderara, September 8th, 2005
Ruggero Cacioppo
Quality Assurance Laboratory Manager

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.3
Linearized                      : No
Page Count                      : 22
XMP Toolkit                     : XMP toolkit 2.9.1-13, framework 1.6
About                           : uuid:a3514609-c3a4-4340-9d1b-ea88dd060eb8
Producer                        : Acrobat Distiller 6.0.1 (Windows)
Creator Tool                    : PScript5.dll Version 5.2
Modify Date                     : 2005:11:16 17:49:43+01:00
Create Date                     : 2005:11:16 17:49:43+01:00
Document ID                     : uuid:497f001e-a3ff-49fe-89dc-07b762727b23
Format                          : application/pdf
Title                           : Microsoft Word - OM-Dragon_Eng.doc
Creator                         : ESchino
Author                          : ESchino
EXIF Metadata provided by EXIF.tools
FCC ID Filing: OMJ0015

Navigation menu