GRYPHON™ M SERIES QUICK REFERENCE DATALOGIC S.p.A. Via Candini 2 40012 - Lippo di Calderara di Reno Bologna - Italy GRYPHON™ M Series Ed.: 11/2005 ALL RIGHTS RESERVED Datalogic reserves the right to make modifications and improvements without prior notification. Datalogic shall not be liable for technical or editorial errors or omissions contained herein, nor for incidental or consequential damages resulting from the use of this material. Product names mentioned herein are for identification purposes only and may be trademarks and or registered trademarks of their respective companies. © Datalogic S.p.A. 2001-2005 Preliminary CONTENTS Updates and Language Availability.....................................................................iv Using GRYPHON™ M ........................................................................................ 1 Charging the Batteries ........................................................................................ 2 GRYPHON™ M Configuration ............................................................................ 3 Using Multiple Readers with Same Cradle.......................................................... 5 GRYPHON™ M Default Configuration................................................................ 6 Technical Features.............................................................................................. 7 Warranty.............................................................................................................. 8 Services And Support ......................................................................................... 8 Patents ................................................................................................................ 8 Compliance ......................................................................................................... 9 Reading Diagrams ............................................................................................ 11 Numeric Table................................................................................................... 12 iii UPDATES AND LANGUAGE AVAILABILITY UK/US The latest drivers and documentation updates for this product are available on Internet. Log on to : www.datalogic.com Su Internet sono disponibili le versioni aggiornate di driver e documentazione di questo prodotto. Questo manuale è disponibile anche nella versione italiana. Collegarsi a : www.datalogic.com Les versions mises à jour de drivers et documentation de ce produit sont disponibles sur Internet. Ce manuel est aussi disponible en version française. Cliquez sur : www.datalogic.com Im Internet finden Sie die aktuellsten Versionen der Treiber und Dokumentation von diesem Produkt. Die deutschsprachige Version dieses Handbuches ist auch verfügbar. Adresse : www.datalogic.com En Internet están disponibles las versiones actualizadas de los drivers y documentación de este producto. También está disponible la versión en español de este manual. Dirección Internet : www.datalogic.com iv GRYPHON™ M SERIES USING GRYPHON™ M SERIES READERS The Gryphon™ M series reader, paired with an OM-Gryphon™ cradle, builds a Cordless Reading System for the collection, decoding and transmission of barcoded data. Gryphon™ M readers automatically scan barcodes at a distance. Simply aim and pull the trigger. Code scanning is performed along the center of the light bar emitted from the reading window. This bar must cover the entire code. READING ANGLE Successful scanning is obtained by tilting the reader with respect to the barcode to avoid direct reflections which impair the reading performance, see the figure below. Successful reading is obtained by an audible tone plus a good-read green spot. Good read LED Good read spot OK Not Advised To start using your Gryphon™ M reading system you must: 1. Connect an OM-Gryphon™ cradle to the Host. For installation and connection information see the OM-Gryphon™ Quick Reference Manual. 2. Charge the Gryphon™ M battery using an OM-Gryphon™ / C-Gryphon™ charger as described in this Quick Reference manual. A full charge takes 3.5 hours with NiMh battery models. 3. Configure the reader as described in this Quick Reference manual. 4. Configure the OM-Gryphon™ cradle. See OM-Gryphon™ Configuration in the “OM-Gryphon™ Quick Reference”. DATALOGIC CHARGING THE BATTERIES By placing the reader onto the OM-Gryphon™ cradle or C-Gryphon™ battery charger it is possible to charge the Gryphon™ M batteries. Make sure the charging LED goes on. The LEDs positioned on the cradle signal the charge status, as described in the following table: LED STATUS Yellow On = OM-Gryphon™ is powered. Power on / Yellow Blinking = OM-Gryphon™ receives data and Data commands from the Host or the reader. Red On = the battery charge is in progress. Charging Red Blinking = the battery reconditioning is in progress. Charge Green On = the battery is completely charged. completed Charging + Red and Green Blinking together = the reader is not Charge correctly placed onto the reader. completed Reconditioning battery button Charging (red LED) Charge completed (green LED) SCH RGE DI Power on / Data (yellow LED) After many recharging cycles NiMh and NiCd batteries may tend to lose their operating autonomy. This condition can be overcome by positioning the Gryphon™ M onto the OM-Gryphon™ / C- Gryphon™ charger and pressing the “battery reconditioning” button. GRYPHON™ M SERIES When the above procedure is no longer effective, the batteries must be changed. To change the batteries of your reader, unscrew the battery cover screw, replace the old batteries with new ones, then insert the cover in the handle and screw it back into place. (See the following figures). CAUTION Dispose of the batteries as required by the relevant laws in force. GRYPHON™ M CONFIGURATION When the OM-Gryphon™ cradle is connected and powered, configure the Gryphon™ M by reading the following codes in the given sequence and follow the instructions. Note: 1. 2. for the numeric code selection of step 3, use the table at the end of this Quick Reference. Restore Gryphon™ M default Ì$+$*oÎ Enter configuration Ì$+;Î Set Radio Address 3. ÌRF8Î four digits for the Gryphon™ M Address (from 0000 to 1999). All readers used in the same area must have different addresses. DATALOGIC Exit and Save configuration 4. 5. Ì$-?Î Read the Bind code to pair the Gryphon™ M to the OM-Gryphon™ cradle. The reader is dedicated to the cradle. Any previously bound reader will be excluded. To connect several readers to the same cradle see the following section "Using Multiple Readers with Same Cradle". Bind Ì$+RN0$-IÎ The green LED on the Gryphon™ M will blink: the reader is ready to be positioned onto the cradle. 6. Firmly position the reader onto the cradle within 10 seconds, a beep will be emitted, signaling that the OM-Gryphon™ cradle has been paired to the Gryphon™ M, and the green LED on the reader will go off. Green LED YOUR READER IS NOW CONFIGURED TO READ BARCODES USING THE DEFAULT VALUES. 7. Configure the OM-Gryphon™ cradle, refer to the “OM-Gryphon™ Quick Reference”. GRYPHON™ M SERIES USING MULTIPLE CRADLE READERS WITH SAME If you want to use several readers associated with the same cradle, you must first Bind the cradle with one of the readers (see previously described configuration procedure). Successive readers can be associated with the same cradle by following the configuration procedure substituting the Bind command with Join. Join 5. Ì$+RN1$-NÎ The green LED on the Gryphon™ M will blink: the reader is ready to be positioned onto the cradle. Complete step 6. If the cradle is not Bound to a reader, its address assumes a random value which can cause conflicts and malfunctions to other cradles within its range. CAUTION DATALOGIC GRYPHON™ M DEFAULT CONFIGURATION DATA FORMAT code identifier disabled (enabled for POS terminals), field adjustment disabled, code length tx not transmitted, character replacement disabled. POWER SAVE scan rate 270 scans/s. READING PARAMETERS operating mode hand-held, hardware trigger, trigger active level, no timeout, Flash On = 1 sec, Flash Off = 0.6 sec, one read per cycle, safety time 0.5 sec, beeper intensity high, tone 2, beeper type monotone, beeper length short, good read spot duration medium DECODING PARAMETERS ink spread enabled, overflow control enabled, interdigit control enabled, Puzzle Solver™ disabled, decoding safety = one read CODE SELECTION Enabled codes • Code PDF417 (only Gryphon™ M200) • EAN 8/EAN 13 / UPC A/UPC E without ADD ON check digit transmitted, no conversions • Interleaved 2/5 check digit control and transmission, variable length code; 4-99 characters • Standard Code 39 no check digit control, variable length code; 1-99 characters • Code 128 variable length code; 1-99 characters Disabled codes for M100 only: EAN 128, ISBT128, Code 93, Codabar, pharmaceutical codes, MSI, Plessey, Telepen, Delta IBM, Code 11, Code 16K, Code 49, RSS Codes Disabled codes for M200 only: EAN 128, ISBT128, Code 93, Codabar, pharmaceutical codes, RSS Codes ADVANCED FORMATTING PARAMETERS concatenation disabled, no advanced formats defined RADIO PARAMETERS radio protocol timeout = 2 seconds, power-off timeout = 4 hours, single store disabled, beeper control for radio response = normal GRYPHON™ M SERIES TECHNICAL FEATURES Electrical Features Battery Type Time of recharge NiMh Operating autonomy (typ. continuous reading) Indicators Max scan rate Optical Features Sensor Illuminator Wavelength Max. LED Output Power Reading field Max. resolution PCS minimum Radio Features Working frequency Bit rate Range (in open air) System Configuration Maximum number of devices per base stations Max. number of devices in the same reading area Environmental Features Working Temperature Storage Temperature (without battery) Humidity Drop resistance Protection class Mechanical Features Weight (with batteries) Dimensions Material 2 AA NiMh* batteries 1.2 V – 1400 mAh 3.5 hours 25,000 reads - NiMh LED, Good Read Spot, Beeper 270 scans/sec CCD solid state (3648 pixels) LED array 630 ~ 670 nm 0.33 mW see reading diagram (p.48) 0.076 mm, 3 mils 15% (Datalogic Test Chart) European Models USA Models 433.92 Mhz 19200 baud 30 m. 910 MHz 36800 baud 15 m. OM-GRYPHON™ STARGATE™ 16 255 2000 0°to + 40 °C / 32° to 104 °F -20°to + 70 °C / - 4° to 158 °F 90% non condensing IEC 68-2-32 Test ED IP30 about 280 g. / 9.87 oz 179 x 81 x 98 mm / 7.04 x 3.18 x 3.85 in ABS and Polycarbonate molded with rubber It is possible to employ also NiCd or non-chargeable Alkaline AA batteries. DATALOGIC WARRANTY Datalogic warranties this product against defects in workmanship and materials, for a period of 24 months from the date of shipment, provided that the product is operated under normal and proper conditions. Datalogic has the faculty to repair or replace the product, these provisions do not prolong the original warranty term. The warranty does not apply to any product that has been subject to misuse, accidental damage, unauthorized repair or tampering. SERVICES AND SUPPORT Datalogic provides several services as well as technical support through its website. Log on to www.datalogic.com and click on the links indicated for further information including: • PRODUCTS Search through the links to arrive at your product page where you can download specific Manuals and Software & Utilities including: - DL Sm@rtSet™ a Windows-based utility program which allows device configuration using a PC. It provides RS232 interface configuration as well as configuration barcode printing. • SERVICES & SUPPORT - Datalogic Services Agreements Warranty Extensions and Maintenance - Authorised Repair Centres • CONTACT US E-mail form and listing of Datalogic Subsidiaries PATENTS This product is licensed by one or more of the following U.S. patents: 4,894,523; 5,021,642; and 6,158,661 This product is covered by one or more of the following patents: U.S. patents 5,992,740; 6,305,606 B1; 6,631,846 B2; 6,517,003 B2; and 6,712,271 B2 European patents 851,378 B1; 895,175 B1; 962,880 B1; 997,760 B1; and 1,128,315 B1 Additional patents pending. GRYPHON™ M SERIES COMPLIANCE This device must be opened by qualified personnel only. The batteries must be removed before opening the device. CLASS 1 LED PRODUCT EN60825-1:(2001) SEE PACKAGE FOR PATENT LISTING Contains FCC ID: OMJ0015 This device complies with PART 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference,and (2) this device must accept any interference received, including interference which may cause undesired operation. LED CLASS CLASS 1 LED PRODUCT EN60825-1:(2001) SEE PACKAGE FOR PATENT LISTING Gryphon™ M100/M200 USA Gryphon™ M100/M200 EU Class 1 LED product. FCC COMPLIANCE Modifications or changes to this equipment without the expressed written approval of Datalogic could void the authority to use the equipment. This device complies with PART 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference which may cause undesired operation. This device contains FCC ID OMJ0015. DATALOGIC RADIO COMPLIANCE Contact the competent authority responsible for the management of radio frequency devices of your country to verify the eventual necessity of a user license. Refer to the web site http://europa.eu.int/comm/enterprise/rtte/spectr.htm for further information. WEEE COMPLIANCE 10 GRYPHON™ M SERIES READING DIAGRAMS GRYPHON™ M100 (STANDARD) M100 (STD) - Reading Zones (10° skew angle) 15 0.13 mm (5 mils) 10 CODE 39 0.076 mm (3 mils) CODE 39 0.13 mm (5 mils) EAN13 M=1 0.33 mm (13 mils) CODE 39 0.50 mm (20 mils) -5 -10 -15 10 15 20 25 30 35 (cm) GRYPHON™ M200 (PDF) M200 (PDF) - Reading Zones (10° skew angle) 10 0.13 mm (5 mils) CODE39 CODE39 0.076 mm 0.13 mm (3 mils) (5 mils) EAN13 M=1 0.33 mm (13 mils) CODE39 0.50 mm (20 mils) -5 -10 10 15 20 25 30 35 (cm) M200 (PDF) - PDF417 codes, Reading Zones (10° skew angle) PDF417 Aspect Ratio 3:1 0.17 mm (6.6mils) 0.38 mm (15mils) -2 -4 -6 0.25 mm (10mils) -8 10 12 14 16 (cm) 11 DATALOGIC NUMERIC TABLE Ì01Î Ì12Î Ì23Î Ì34Î Ì45Î Ì56Î Ì67Î Ì78Î Ì89Î Ì9:Î 12 DATALOGIC S.p.A., Via Candini, 2 40012 - Lippo di Calderara Bologna - Italy 05 dichiara che declares that the déclare que le bescheinigt, daß das Gerät declare que el GRYPHON M100, Cordless Bar Code Reader GRYPHON M200, Cordless Bar Code Reader e tutti i suoi modelli and all its models et tous ses modèles und seine modelle y todos sus modelos sono conformi alla Direttiva del Consiglio Europeo sottoelencata: are in conformity with the requirements of the European Council Directive listed below: sont conformes aux spécifications de la Directive de l'Union Européenne ci-dessous: der nachstehenden angeführten Direktive des Europäischen Rats entsprechen: cumple con los requisitos de la Directiva del Consejo Europeo, según la lista siguiente: 1999/5/EEC R&TTE Questa dichiarazione è basata sulla conformità dei prodotti alle norme seguenti: This declaration is based upon compliance of the products to the following standards: Cette déclaration repose sur la conformité des produits aux normes suivantes: Diese Erklärung basiert darauf, daß das Produkt den folgenden Normen entspricht: Esta declaración se basa en el cumplimiento de los productos con las siguientes normas: ETSI EN 301 489-3 v.1.4.1, AUGUST 2002: ELECTROMAGNETIC COMPATIBILITY AND RADIO SPECTRUM MATTERS (ERM); ELECTROMAGNETIC COMPATIBILITY (EMC) STANDARD FOR RADIO EQUIPMENT AND SERVICES; PART 3: SPECIFIC CONDITIONS FOR SHORT-RANGE DEVICES (SRD) OPERATING ON FREQUENCIES BETWEEN 9 KHZ AND 40 GHZ ETSI EN 300 220 v.1.1.1, SEPTEMBER 2004: ELECTROMAGNETIC COMPATIBILITY AND RADIO SPECTRUM MATTERS (ERM); SHORT RANGE DEVICES (SRD); RADIO EQUIPMENT TO BE USED IN THE 25 MHZ TO 1000 MHZ FREQUENCY RANGE WITH POWER LEVELS RANGING UP TO 500 MW; PART 3: HARMONIZED EN COVERING ESSENTIAL REQUIREMENTS UNDER ARTICLE 3.2 OF THE R&TTE DIRECTIVE EN 60950-1, December 2001: INFORMATION TECHNOLOGY EQUIPMENT – SAFETY – PART 1: GENERAL REQUIREMENTS Lippo di Calderara, September 8th, 2005 Ruggero Cacioppo Quality Assurance Laboratory Manager
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.3 Linearized : No Page Count : 17 XMP Toolkit : XMP toolkit 2.9.1-13, framework 1.6 About : uuid:fcd1963c-d259-4b28-89c5-8de850608fd4 Producer : Acrobat Distiller 6.0.1 (Windows) Creator Tool : PScript5.dll Version 5.2 Modify Date : 2005:11:17 15:59:40+01:00 Create Date : 2005:11:17 15:59:40+01:00 Document ID : uuid:ea996c58-24fd-40ee-bc45-db56891e3248 Format : application/pdf Title : Microsoft Word - Gryphon M_Eng.doc Creator : ESchino Author : ESchinoEXIF Metadata provided by EXIF.tools