Datalogic 0015 RADIO STAR-MODULE 910 User Manual Gryphon M Eng

Datalogic SpA RADIO STAR-MODULE 910 Gryphon M Eng

Gryphon User Guide

      GRYPHON™ M SERIES  QUICK REFERENCE
               DATALOGIC S.p.A. Via Candini 2 40012 - Lippo di Calderara di Reno Bologna - Italy    GRYPHON™ M Series  Ed.: 11/2005                   ALL RIGHTS RESERVED Datalogic reserves the right to make modifications and improvements without prior notification.  Datalogic shall not be liable for technical or editorial errors or omissions contained herein, nor for incidental or consequential damages resulting from the use of this material.  Product names mentioned herein are for identification purposes only and may be trademarks and or registered trademarks of their respective companies.  © Datalogic S.p.A. 2001-2005  Preliminary
  iii  CONTENTS  Updates and Language Availability.....................................................................iv Using GRYPHON™ M ........................................................................................ 1 Charging the Batteries ........................................................................................ 2 GRYPHON™ M Configuration ............................................................................ 3 Using Multiple Readers with Same Cradle.......................................................... 5 GRYPHON™ M Default Configuration................................................................ 6 Technical Features.............................................................................................. 7 Warranty.............................................................................................................. 8 Services And Support ......................................................................................... 8 Patents ................................................................................................................ 8 Compliance ......................................................................................................... 9 Reading Diagrams ............................................................................................ 11 Numeric Table................................................................................................... 12
 iv   UPDATES AND LANGUAGE AVAILABILITY     UK/US  The latest drivers and documentation updates for this product are available on Internet. Log on to : www.datalogic.com    I  Su Internet sono disponibili le versioni aggiornate di driver e documentazione di questo prodotto. Questo manuale è disponibile anche nella versione italiana. Collegarsi a : www.datalogic.com    F  Les versions mises à jour de drivers et documentation de ce produit sont disponibles sur Internet. Ce manuel est aussi disponible en version française. Cliquez sur : www.datalogic.com    D  Im Internet finden Sie die aktuellsten Versionen der Treiber und Dokumentation von diesem Produkt. Die deutschsprachige Version dieses Handbuches ist auch verfügbar. Adresse : www.datalogic.com    E  En Internet están disponibles las versiones actualizadas de los drivers y documentación de este producto. También está disponible la versión en español de este manual. Dirección Internet : www.datalogic.com
GRYPHON™ M SERIES  1   USING GRYPHON™ M SERIES READERS  The Gryphon™ M series reader, paired with an OM-Gryphon™ cradle, builds a Cordless Reading System for the collection, decoding and transmission of barcoded data. Gryphon™ M readers automatically scan barcodes at a distance. Simply aim and pull the trigger. Code scanning is performed along the center of the light bar emitted from the reading window. This bar must cover the entire code.   READING ANGLE  Successful scanning is obtained by tilting the reader with respect to the barcode to avoid direct reflections which impair the reading performance, see the figure below.  Successful reading is obtained by an audible tone plus a good-read green spot.                OK  Not Advised   To start using your Gryphon™ M reading system you must:  1.  Connect an OM-Gryphon™ cradle to the Host. For installation and connection information see the OM-Gryphon™ Quick Reference Manual.  2.  Charge the Gryphon™ M battery using an OM-Gryphon™ / C-Gryphon™ charger as described in this Quick Reference manual. A full charge takes 3.5 hours with NiMh battery models.  3.  Configure the reader as described in this Quick Reference manual.  4.  Configure the OM-Gryphon™ cradle. See OM-Gryphon™ Configuration in the “OM-Gryphon™ Quick Reference”.  Good read spotGood read LED
DATALOGIC 2   CHARGING THE BATTERIES  By placing the reader onto the OM-Gryphon™ cradle or C-Gryphon™ battery charger it is possible to charge the Gryphon™ M batteries. Make sure the charging LED goes on.  The LEDs positioned on the cradle signal the charge status, as described in the following table:   LED  STATUS  Power on / Data Yellow On = OM-Gryphon™ is powered. Yellow Blinking = OM-Gryphon™ receives data and commands from the Host or the reader. Charging  Red On = the battery charge is in progress. Red Blinking = the battery reconditioning is in progress. Charge completed  Green On = the battery is completely charged. Charging + Charge completed Red and Green Blinking together = the reader is not correctly placed onto the reader.         DISCHARGE  After many recharging cycles NiMh and NiCd batteries may tend to lose their operating autonomy. This condition can be overcome by positioning the Gryphon™ M onto the OM-Gryphon™ / C- Gryphon™ charger and pressing the “battery reconditioning” button. Power on / Data (yellow LED) Reconditioning battery button Charging (red LED) Charge completed (green LED)
GRYPHON™ M SERIES  3   When the above procedure is no longer effective, the batteries must be changed. To change the batteries of your reader, unscrew the battery cover screw, replace the old batteries with new ones, then insert the cover in the handle and screw it back into place. (See the following figures).        CAUTION Dispose of the batteries as required by the relevant laws in force.   GRYPHON™ M CONFIGURATION  When the OM-Gryphon™ cradle is connected and powered, configure the Gryphon™ M by reading the following codes in the given sequence and follow the instructions.  Note:  for the numeric code selection of step 3, use the table at the end of this Quick Reference.  Restore Gryphon™ M default 1. Ì$+$*oÎ   Enter configuration 2. Ì$+;Î   Set Radio Address 3.  ÌRF8Î + four digits for the Gryphon™ M Address (from 0000 to 1999).  All readers used in the same area must have different addresses.  +
DATALOGIC 4   Exit and Save configuration 4. Ì$-?Î   5. Read the Bind code to pair the Gryphon™ M to the OM-Gryphon™ cradle. The reader is dedicated to the cradle. Any previously bound reader will be excluded. To connect several readers to the same cradle see the following section "Using Multiple Readers with Same Cradle".  Bind Ì$+RN0$-IÎ    The green LED on the Gryphon™ M will blink: the reader is ready to be positioned onto the cradle.   6. Firmly position the reader onto the cradle within 10 seconds, a beep will be emitted, signaling that the OM-Gryphon™ cradle has been paired to the Gryphon™ M, and the green LED on the reader will go off.      YOUR READER IS NOW CONFIGURED TO READ BARCODES USING THE DEFAULT VALUES.  7. Configure the OM-Gryphon™ cradle, refer to the “OM-Gryphon™ Quick Reference”.   Green LED
GRYPHON™ M SERIES  5   USING MULTIPLE READERS WITH SAME CRADLE  If you want to use several readers associated with the same cradle, you must first  Bind  the cradle with one of the readers (see previously described configuration procedure).  Successive readers can be associated with the same cradle by following the configuration procedure substituting the Bind command with Join.   5. Join Ì$+RN1$-NÎ   The green LED on the Gryphon™ M will blink: the reader is ready to be positioned onto the cradle. Complete step 6.    CAUTION If the cradle is not Bound to a reader, its address assumes a random value which can cause conflicts and malfunctions to other cradles within its range.
DATALOGIC 6   GRYPHON™ M DEFAULT CONFIGURATION  DATA FORMAT code identifier disabled (enabled for POS terminals), field adjustment disabled, code length tx not transmitted, character replacement disabled. POWER SAVE scan rate 270 scans/s. READING PARAMETERS operating mode hand-held, hardware trigger, trigger active level, no timeout, Flash On = 1 sec, Flash Off = 0.6 sec, one read per cycle, safety time 0.5 sec, beeper intensity high, tone 2, beeper type monotone, beeper length short, good read spot duration medium DECODING PARAMETERS ink spread enabled, overflow control enabled, interdigit control enabled, Puzzle Solver™ disabled, decoding safety = one read CODE SELECTION Enabled codes •  Code PDF417 (only Gryphon™ M200) •  EAN 8/EAN 13 / UPC A/UPC E without ADD ON check digit transmitted, no conversions •  Interleaved 2/5 check digit control and transmission, variable length code; 4-99 characters •  Standard Code 39 no check digit control, variable length code; 1-99 characters •  Code 128 variable length code; 1-99 characters Disabled codes for M100 only: EAN 128, ISBT128, Code 93, Codabar, pharmaceutical codes, MSI, Plessey, Telepen, Delta IBM, Code 11, Code 16K, Code 49, RSS Codes Disabled codes for M200 only: EAN 128, ISBT128, Code 93, Codabar, pharmaceutical codes, RSS Codes ADVANCED FORMATTING PARAMETERS concatenation disabled, no advanced formats defined RADIO PARAMETERS radio protocol timeout = 2 seconds, power-off timeout = 4 hours, single store disabled, beeper control for radio response = normal
GRYPHON™ M SERIES  7   TECHNICAL FEATURES  Electrical Features Battery Type  2 AA NiMh* batteries 1.2 V – 1400 mAh Time of recharge NiMh  3.5 hours Operating autonomy (typ. continuous reading)  25,000 reads - NiMh Indicators  LED, Good Read Spot, Beeper Max scan rate  270 scans/sec Optical Features Sensor  CCD solid state (3648 pixels) Illuminator LED array Wavelength  630 ~ 670 nm Max. LED Output Power  0.33 mW Reading field  see reading diagram (p.48) Max. resolution  0.076 mm, 3 mils PCS minimum  15% (Datalogic Test Chart) Radio Features  European Models  USA Models Working frequency  433.92 Mhz  910 MHz Bit rate  19200 baud  36800 baud Range (in open air)  30 m.  15 m. System Configuration  OM-GRYPHON™  STARGATE™ Maximum number of devices per base stations  16 255 Max. number of devices in the same reading area  2000 Environmental Features Working Temperature  0°to + 40 °C / 32° to 104 °F Storage Temperature (without battery)  -20°to + 70 °C / - 4° to 158 °F Humidity  90% non condensing Drop resistance  IEC 68-2-32 Test ED Protection class  IP30 Mechanical Features Weight (with batteries)  about 280 g. / 9.87 oz Dimensions  179 x 81 x 98 mm / 7.04 x 3.18 x 3.85 in Material  ABS and Polycarbonate molded with rubber   *  It is possible to employ also NiCd or non-chargeable Alkaline AA batteries.
DATALOGIC 8   WARRANTY  Datalogic warranties this product against defects in workmanship and materials, for a period of 24 months from the date of shipment, provided that the product is operated under normal and proper conditions.  Datalogic has the faculty to repair or replace the product, these provisions do not prolong the original warranty term. The warranty does not apply to any product that has been subject to misuse, accidental damage, unauthorized repair or tampering.    SERVICES AND SUPPORT  Datalogic provides several services as well as technical support through its website. Log on to www.datalogic.com and click on the links indicated for further information including: •  PRODUCTS Search through the links to arrive at your product page where you can download specific Manuals and Software & Utilities including: - DL Sm@rtSet™ a Windows-based utility program which allows device configuration using a PC. It provides RS232 interface configuration as well as configuration barcode printing. •  SERVICES & SUPPORT - Datalogic  Services - Warranty Extensions and Maintenance Agreements -  Authorised Repair Centres •  CONTACT US E-mail form and listing of Datalogic Subsidiaries   PATENTS  This product is licensed by one or more of the following U.S. patents:  4,894,523; 5,021,642; and 6,158,661  This product is covered by one or more of the following patents:  U.S. patents  5,992,740; 6,305,606 B1; 6,631,846 B2; 6,517,003 B2; and 6,712,271 B2 European patents  851,378 B1; 895,175 B1; 962,880 B1; 997,760 B1; and 1,128,315 B1  Additional patents pending.
GRYPHON™ M SERIES  9   COMPLIANCE  This device must be opened by qualified personnel only. The batteries must be removed before opening the device.   LED CLASS  Contains FCC ID: OMJ0015This device complies with PART 15 of theFCC Rules. Operation is subject to thefollowing two conditions:(1) This device may not cause harmfulinterference,and(2) this device must accept anyinterference received, includinginterference which may causeundesired operation.CLASS 1 LED PRODUCTSEE PACKAGE FOR PATENT LISTING Gryphon™ M100/M200 USA CLASS 1 LED PRODUCTSEE PACKAGE FOR PATENT LISTING Gryphon™ M100/M200 EU Class 1 LED product.   FCC COMPLIANCE  Modifications or changes to this equipment without the expressed written approval of Datalogic could void the authority to use the equipment.  This device complies with PART 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference which may cause undesired operation.  This device contains FCC ID OMJ0015.   EN60825-1:(2001)EN60825-1:(2001)
DATALOGIC 10   RADIO COMPLIANCE  Contact the competent authority responsible for the management of radio frequency devices of your country to verify the eventual necessity of a user license. Refer to the web site http://europa.eu.int/comm/enterprise/rtte/spectr.htm for further information.     WEEE COMPLIANCE
GRYPHON™ M SERIES  11   READING DIAGRAMS  GRYPHON™ M100 (STANDARD) 0 5 10 15 20 25 30 35-15-10-5051015M100 (STD) -  Reading Zones  (10° skew angle)(cm)CODE 390.13 mm(5 mils)EAN13 M=10.33 mm(13 mils)CODE 390.50 mm(20 mils)CODE 390.076 mm(3 mils)0.13 mm(5 mils)  GRYPHON™ M200 (PDF) 0 5 10 15 20 25 30 35-10-50510M200 (PDF) -  Reading Zones  (10° skew angle)(cm)CODE390.076 mm(3 mils)CODE390.13 mm(5 mils)EAN13 M=10.33 mm(13 mils)CODE390.50 mm(20 mils)0.13 mm(5 mils)  0246810 12 14 16-8-6-4-202468(cm)M200 (PDF) - PDF417 codes, Reading Zones  (10° skew angle)PDF417 Aspect Ratio 3:10.25 mm(10mils)0.17 mm(6.6mils)0.38 mm(15mils)
DATALOGIC 12   NUMERIC TABLE  Ì01Î    0      Ì12Î   1 Ì23Î    2      Ì34Î   3 Ì45Î    4      Ì56Î   5 Ì67Î    6      Ì78Î   7 Ì89Î    8      Ì9:Î   9
    05 DATALOGIC S.p.A., Via Candini, 2 40012 - Lippo di Calderara Bologna - Italy   dichiara che declares that the déclare que le bescheinigt, daß das Gerät declare que el   GRYPHON M100, Cordless Bar Code Reader GRYPHON M200, Cordless Bar Code Reader    e tutti i suoi modelli   and all its models   et tous ses modèles   und seine modelle   y todos sus modelos  sono conformi alla Direttiva del Consiglio Europeo sottoelencata: are in conformity with the requirements of the European Council Directive listed below: sont conformes aux spécifications de la Directive de l'Union Européenne ci-dessous: der nachstehenden angeführten Direktive des Europäischen Rats entsprechen: cumple con los requisitos de la Directiva del Consejo Europeo, según la lista siguiente: 1999/5/EEC R&TTE  Questa dichiarazione è basata sulla conformità dei prodotti alle norme seguenti: This declaration is based upon compliance of the products to the following standards: Cette déclaration repose sur la conformité des produits aux normes suivantes: Diese Erklärung basiert darauf, daß das Produkt den folgenden Normen entspricht: Esta declaración se basa en el cumplimiento de los productos con las siguientes normas:   ETSI EN 301 489-3 v.1.4.1, AUGUST 2002: ELECTROMAGNETIC  COMPATIBILITY AND RADIO SPECTRUM MATTERS  (ERM); ELECTROMAGNETIC  COMPATIBILITY  (EMC) STANDARD FOR RADIO EQUIPMENT AND SERVICES; PART  3: SPECIFIC CONDITIONS FOR SHORT-RANGE  DEVICES  (SRD) OPERATING ON FREQUENCIES BETWEEN 9 KHZ AND 40 GHZ   ETSI EN 300 220 v.1.1.1, SEPTEMBER 2004:ELECTROMAGNETIC COMPATIBILITY AND RADIO SPECTRUM MATTERS  (ERM); SHORT  RANGE  DEVICES  (SRD); RADIO EQUIPMENT TO BE USED IN THE 25 MHZ TO 1000 MHZ FREQUENCY RANGE WITH POWER LEVELS RANGING UP TO 500 MW; PART  3: HARMONIZED  EN  COVERING ESSENTIAL REQUIREMENTS UNDER ARTICLE 3.2 OF THE R&TTE DIRECTIVE   EN 60950-1, December 2001: INFORMATION TECHNOLOGY EQUIPMENT – SAFETY – PART 1: GENERAL REQUIREMENTS     Lippo di Calderara, September 8th, 2005        Ruggero Cacioppo   Quality Assurance Laboratory Manager

Navigation menu