Datamars GATEMAX RFID Reader User Manual GATE MAX Instruction 045 07

Datamars SA RFID Reader GATE MAX Instruction 045 07

User Maual

Download: Datamars GATEMAX RFID Reader User Manual GATE MAX Instruction 045 07
Mirror Download [FCC.gov]Datamars GATEMAX RFID Reader User Manual GATE MAX Instruction 045 07
Document ID865122
Application IDxnJQOubOyZMqQS12TJDJ9Q==
Document DescriptionUser Maual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize110.72kB (1384020 bits)
Date Submitted2007-11-07 00:00:00
Date Available2007-11-07 00:00:00
Creation Date2007-10-22 18:44:24
Producing SoftwareAcrobat Distiller 7.0.5 for Macintosh
Document Lastmod2007-10-24 08:49:09
Document TitleGATE MAX Instruction-045-07
Document CreatorQuarkXPress: pictwpstops filter 1.0
Document Author: silver

GATE MAX READER
User Manual
This manual describes the use of the GATE MAX reader.
The
GATE MAX reader is a high-performance Radio Frequency Transponder reader.
The
GATE MAX reads all ISO 11784/85 FDX/B Transponders for the electronic
identification of animals. It helps to reunite the animal with its owner.
The
GATE MAX reader and the
Transponders are manufactured
according to ISO Standards 11784 & 11785 for the electronic identification of animals and are
products.
Index
0. Important
1. Introduction
2. GATE MAX Reader System
3. Main Advantages
4. How to Connect
5. Operation (for readers with display)
6. How to Use the GATE MAX Reader
7. Settings and User Interface
7.1.
7.1.1.
7.1.2.
7.2.
7.3.
Main Screen
Reading OFF
Reading ON
Option Menu
Noise Level
8. Reader Connected to a PC
or a Data Recording System
8.1.
PC Commands
9. Cleaning
10. Regulations
0. Important
3. Main Advantages
This product is sensitive to any external radio frequency disturbances due to
the large size of the antennas.
The GATE MAX reader is designed to facilitate pet identification. The main
benefits are automatic recognition of the transponder FDX-B (ISO Standard),
quick detection (normally no need to scan the pet manually), a safer use for
the employees and an automatic process (connection to a database and PC).
Therefore, be aware of its surrounding environment. The following objects
can cause interference with the GATE MAX reader and for this reason it is
recommended to maintain a distance of 2 to 3 meters:
■
■
■
■
Large PC/ TV screen (not flat screens)
Lamps, motors
Metal objects (scales, tables, gates, cages, etc.)
Other RFID handheld readers (e.g. ISO MAX IV)
1. Introduction
The GATE MAX reader has been especially designed for shelters, veterinary
clinics and borders to facilitate the pet identification process. The GATE MAX
system is composed of a reader, a gate antenna and a power supply. The
GATE MAX reader allows a hands free direct identification of the pet when
passing through the antennas. The pet simply goes through the reader, the ID
number gets read automatically and displayed either on the touch screen
(optionally provided) mounted on the antenna or on the computer screen of
the clinic, shelter or border. No manual tipping is necessary, which avoids
human error in typing the 15 digits ID number and eases the process.
4. How to Connect
Before start:
Plug in the RS232 cable from the GATE MAX reader unit connector to the
serial communication COM port of your PC. Optionally, you can plug in a
USB cable and install its software on your PC. Then plug in the power cable.
The reader is automatically powered by using the ON/OFF switch.
Power Cable
RS-232 Cable
USB Cable
5. Operation (for readers with display)
To start reading push the ‘Start’ button on the touch screen (optionally provided).
The reader turns on the transmission and now is ready to detect transponders. The display shows the status of the reader with a blinking text ‘Reading’
and with a blinking button.
2. GATE MAX Reader System
The GATE MAX reader system is in accordance with ISO Standard 11785
and reads the ISO tags FDX-B. The reading range covers the area between
the antennas completely. The reader can be connected to a PC: the ID will
be displayed either on the touch screen mounted on the antenna (optionally
provided) or on the PC screen. The reader includes a RS232 interface for
data transmission (ASCII) and can include, alternatively, a USB interface.
This system can easily be integrated into an Open Office Package for a
database which is used in shelters or veterinary clinics.
When a transponder is detected, the ID number is shown on the screen. It
remains displayed until a new transponder is detected or ”Clear ID” is
pressed.
To stop the transmission press ‘Stop’. The display shows the status writing
‘Stand-by’.
6. How to Use the GATE MAX Reader
■
When a pet passes through the antennas, the transponder is automatically detected. If not, make the dog walk slowly 2-3 times through the
antennas. A short stand still of 2 seconds between the antennas may
also help.
■
If a transponder is detected between the antennas, the code is automatically read and sent through the RS232 communication cable once.
At the same time an ID number is written on the screen.
■
If no transponder is present, the read cycle continues. The system
reads 30 times per second.
■
The GATE MAX reader system detects around 80% of the ISO
transponders during the first passage.
■
If the pet’s transponder is still not detected after the 3rd passage, we
recommend using a hand-held multi reader with a large antenna
(example ISO MAX IV) in order to determine or exclude the presence of
an animal identification transponder.
GATE MAX Reader
981094573680810
OK
Display number?
Walk through
NO
if no number
1. Let the pet walk through the reader.
The transponder is automatically detected.
please try again
2. If no number is displayed, please try again.
The reader did not detect a transponder
this time.
NO 3rd time
Verify with handheld
reader
3. If no number is displayed after three times,
please verify that a transponder exists with
a portable reader.
7. Settings and User Interface
7.1
Main Screen
7.1.1 Reading OFF
Test Button: Goes to the noise level screen.
Back Button: Comes back to the main screen.
On the top right corner of the screen there is the company name followed
by the display firmware’s version followed by the reader firmware’s version.
7.3
Noise Level
Start Button: Turns on the transmission and reads continuously.
Option Button: Go to the ‘option’ menu.
7.1.2 Reading ON
This screen shows the noise level detected by the antenna.
The noise level must be low to have the maximum performance.
Back Button: Come back to the Option Menu.
Stop Button: Turns off the transmission and stops the reader.
Clear ID Button: Clears the ID on the display screen to allow an easier
visualization of the next ID. When Single Mode is selected, it reads another
time the same ID.
The ID is shown below the ‘ID:’ text. It is composed of 15 numbers.
The Country Code is written with 3 numbers or 3 characters according to
the ISO 3166 country code table.
7.2
Option Menu
If noise is high, please check the surroundings to detect possible sources of
interference (see under ”Important”)
If noise = 0, there is a transmission problem. Try to restart the GATE MAX
antenna and check the surroundings for possible sources of interference. If
the problem persists, please contact Datamars / After Sales Service.
8. Reader Connected to a PC
or a Data Recording System
The system has a RS232 interface which communicates with the PC via a
serial port (COM) sending all data in ASCII. HyperTerminal can be used as
a communication program.
Start > Programs > Accessories > Communications > Hyper Terminal
Set the communication parameters as follows:
Beep Enable / Disable:
Set the status of the internal beeper. If enabled, a sound of about 1 second
is generated when a new ID is detected
Lamp Enable / Disable:
Set the status of the light. If enabled, a light of 2 seconds is generated when
a new ID is detected
Single / Continuous Mode:
If ‘continuous’, the system sends the ID continuously (about 30 times per
second) to the PC/Display, if ‘single’, it sends the ID only when it is a new
one.
Where ‘Name’ is
a customer choice.
Sleep Mode Enable / Disable:
If enabled, the reading mode is turned off after 5 minutes when no TAG has
been detected. If disabled, the reader is permanently in transmission.
Select the corresponding serial port (COM).
Note: In general, the COM 1 port is the first one and the USB port the last
one in the list.
‘.be1’
Answer
‘.be0’
Answer
‘.li1’
Answer
‘.li0’
Answer
‘.lc1’
Answer
‘.lc0’
Answer
‘.s1’
8.1
PC Commands
To send a command to the reader simply type the following characters:
‘.x’
Answer
Call the status of the reader
STATUS:
Console (C)
Reading (R)
Beep (BE)
Light (L)
Lock Code (LC)
Sleep Mode (S)
Version (V)
‘.r1’
Answer
‘.r0’
Answer
1.2
Answer
‘.s0’
Answer
‘.c1’
Beeper ON, set the status of the internal beeper (optional).
If enable, a sound of about 1 second is generated when a new
ID is detected
> BEEP ON
Beeper OFF, disable the beep.
> BEEP OFF
Light Indicator on when a TAG is detected. The light stay on for
about 2 s.
> LIGHT INDICATOR ON
Light Indicator off.
> LIGHT INDICATOR OFF
Lock code mode, Lock the same code forever. This will unlock
only when another TAG is read
> LOCK CODE
Unlock code, no lock code. Every code read is send to the PC.
> UNLOCK CODE
Sleep mode ON, turn off the reader after 5 minutes when no
TAG has been detected.
> SLEEP MODE ON
Sleep mode OFF, the reader is permanently in transmission.
> SLEEP MODE OFF
Answer
Console ON, reader answer with the text of the command
which is show on the terminal
> CONSOLE TURNED ON
Console OFF, only the IDs are send by the reader to PC
(no command’s texts)
> CONSOLE TURNED OFF
‘.v’
Answer
Give the firmware version of the Reader
> VERSION: 1.2
‘.cr1’
Answer
‘.cr0’
Answer
Carriage return at the end of the telegram
> WITH CARRIAGE RETURN
No carriage return at the end of the telegram
> NO CARRIAGE RETURN
‘.nl1’
Answer
‘.nl0’
Answer
Line feed (new line) at the end of the telegram
> WITH LINE FEED
No line feed (new line) at the end of the telegram
> NO LINE FEED
‘.rd’
Answer
restore default parameters
> DEFAULT PARAMETERS RESTORED
Answer
‘.c0’
Turn on the transmission and the reading mode
> READING ON
Turn off the reader (stand-by).
> READING OFF
9. Cleaning
10. Regulations
Clean the antennas with a wet cloth. No water contact on the display or any
outer cable.
10.1.
Equipment Modification
Equipment modifications not expressly approved by Datamars SA, CH-6930
Bedano, the party responsible for FCC compliance, are forbidden. Such
modifications could void the user’s warranty and authority to operate the
equipment and cause hazardous conditions.
10.2.
EN 300330-1/-2 (europe)
The GATE MAX reader system is a sending and receiving equipment and is
in accordance with the R & TTE directive EN 300 330-1/-2.
The GATE MAX reader system fulfils the requirements of this regulation.
10.3.
FCC (usa)
To comply with FCC part 15 rules in the United States, the system must be
professionally installed to ensure compliance with the Part 15 certification.
It is the responsibility of the operator and professional installer to ensure
that only certified systems are deployed in the United States. The use of the
system in any other combination (such as co-located antennas transmitting
the same information) is expressly forbidden.
10.4.
CE certification
The system GATE MAX reader is in accordance with the requirements of
protection, which are defined in the regulation concerning the electromagnetic tolerability EN301 489-1, -3, emitted by the council for the
harmonisation of regulations in the member countries. The European
Community regulation for Low Frequency, EN 60950, is respected.
The GATE MAX reader system fulfils the requirements of this regulation.
10.5.
Warranty
© 2007 Datamars SA version 1.0/July 2007
If the reader is opened by not certified personnel by mistake the warranty is
voided and we cannot guarantee the fulfillments of the above-mentioned
regulations.
DATAMARS SA Via ai Prati
6930 Bedano-Lugano
Switzerland
Phone +41 91 935 73 80
Fax +41 91 945 03 30
www.datamars.com

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
XMP Toolkit                     : 3.1-702
Producer                        : Acrobat Distiller 7.0.5 for Macintosh
Create Date                     : 2007:10:22 18:44:24+02:00
Modify Date                     : 2007:10:24 08:49:09+02:00
Creator Tool                    : QuarkXPress: pictwpstops filter 1.0
Metadata Date                   : 2007:10:24 08:49:09+02:00
Format                          : application/pdf
Title                           :  GATE MAX Instruction-045-07
Creator                         : silver
Document ID                     : uuid:a34b5705-7468-4eb4-b822-99a8a213e8db
Instance ID                     : uuid:cfffe035-7d41-487e-adb5-295a8f49b79b
Page Count                      : 7
Author                          : silver
EXIF Metadata provided by EXIF.tools
FCC ID Filing: NDX-GATEMAX

Navigation menu