Davis Instruments DWW6361 Soil Moisture Station, 6361 User Manual 6361 SMT Station FCC

Davis Instruments Soil Moisture Station, 6361 6361 SMT Station FCC

Manual

Download: Davis Instruments DWW6361 Soil Moisture Station, 6361 User Manual 6361 SMT Station FCC
Mirror Download [FCC.gov]Davis Instruments DWW6361 Soil Moisture Station, 6361 User Manual 6361 SMT Station FCC
Document ID165278
Application IDvQVCulIyuBUqlw0ypLTlRw==
Document DescriptionManual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize48.42kB (605190 bits)
Date Submitted2001-08-20 00:00:00
Date Available2001-08-20 00:00:00
Creation Date2001-08-07 08:13:30
Producing SoftwareAcrobat Distiller 5.0 for Macintosh
Document Lastmod2001-08-07 08:13:30
Document Title6361 SMT Station FCC
Document CreatorFrameMaker 5.5: AdobePS 8.7.2 (104)
Document Author: Davis

WIRELESS
SOIL MOISTURE/
TEMPERATURE STATION
INSTALLATION MANUAL
The Wireless Soil Moisture/Temperature Station, referred to in this document
at the Soil Moisture Station, is for use with Wireless Vantage ProTM Weather Stations.
Components
The Soil Moisture Station includes the following components and mounting
hardware:
Shelter
Temperature Probe
with 15" (4.6 m) of cable
Soil Moisture Sensor
with 15" (4.6 m) of cable
8" Cable Ties
4" Cable Ties
3-Volt Lithium Battery
Components
Product # 6361
U-Bolts
1/4" Flat Washers
1/4" x 1-1/2"
Lag Screws
1/4" Lock Washers
1/4" Hex Nuts
Mounting Hardware
Tools for Setup
In addition to the components shown, you will need some or all of the following materials:
✦ Adjustable wrench or 7/16" wrench
✦ Ballpoint pen or paper clip (small pointed object of some kind)
✦ Drill and 3/16" (5 mm) drill bit (if mounting on a vertical surface)
✦ Stepped Sensor Installation Tool
Installation Steps
For ease of installation, please follow steps in the order presented.
✦ Prepare the Soil Moisture station, page 3
✦ Insert the battery, page 3
✦ Set the transmitter ID, page 3
✦ Set ID on the Soil Moisture Station using DIP switches, page 3
✦ Set the console to recognize the signals, page 5
✦ View current temperature, page 5
✦ (If you don’t see temperature from the correct Station No., put the
transmitter in TEST mode, page 5)
✦ Choose a location for the Soil Moisture Station, page 6
✦ Test transmission from the proposed mounting location, page 7
✦ Mount the Soil Moisture Station, page 8
✦ A note on securing cables, page 10
For Technical Support, please see “Contacting Davis Technical Support” on
page 10.
Page 2
Wireless Soil Moisture/ Temperature Station
Preparing the Soil Moisture Station
The illustration below shows the location of the DavisTalk transmitter DIP
Switches, the battery mounting location, and the terminal blocks used to
connect the soil moisture sensors and temperature probes.
Insert the 3-volt lithium battery into the battery holder, matching the “+”
sign on the battery with the “+” sign on the SIM.
3-Volt
Lithium Battery
DIP
Switches
Terminal
Blocks
Sensor Interface Module on Soil Moisture Station
Note the location of the DIP switches. You will work with them during the
next installation step.
Setting the Transmitter ID
Each wireless transmitting station must be set to one of eight DavisTalk transmitter IDs. DIP switches #1, 2 and 3 on the SIM allow you to control the ID —
the “channel” the station will transmit on. (DIP switch #4 is used for transmission testing, not for transmitter ID.)
A DavisTalk transmitter and receiver communicate with each other only when
both are set to the same ID.
Preparing the Soil Moisture Station
Page 3
The factory default transmitter ID is ‘1’. Looking at the table below, you can
see that means the DIP switches are in the OFF position when each
transmitting station leaves the factory. This is true for all of Davis’ wireless
equipment.
The default setting on a Wireless Vantage Pro console is “ON (ISS).” The ISS
is included with every Wireless Vantage Pro, so the console/receiver is set to
find the ISS on DavisTalk channel 1.
Verify the DavisTalk channel used by your ISS, as well as any other
DavisTalk channels already in use by your Vantage Pro Weather Station
Configure the Soil Moisture Station to a DavisTalk channel not already in
use.
Use a ballpoint pen or paper clip to toggle DIP switches #1, 2, and 3. The
settings for transmitter IDs 1 – 8 are shown in the table below:
ID CODE
SWITCH 1
SWITCH 2
SWITCH 3
#1 (default)
#2
#3
#4
#5
#6
#7
#8
off
off
off
off
ON
ON
ON
ON
off
off
ON
ON
off
off
ON
ON
off
ON
off
ON
off
ON
off
ON
Use this table to ensure that each wireless transmitting station in your
system is broadcasting on its own transmitter ID.
Battery Holder
ON
DIP Switches
DIP Switches in Top-right Corner of SIM (Illustration has been enlarged for clarity)
Page 4
Wireless Soil Moisture/ Temperature Station
Setting Console/Receiver(s) to Same ID
1. Put your console into Setup Mode — press and hold the DONE key and press the
DOWN arrow key.
The console will show you Screen 1: Transmitters. You should see the words:
“RECEIVING FROM...” and “STATION NO.” followed by the transmitter
IDs that your console detects. One of these should be the ID number you just
set on the Soil Moisture Station transmitter. If you don’t see it, make sure the
console is within 10' of the transmitter, and verify that you set the DIP
switches correctly. If you still don’t see it, go to “TEST mode” on the next
page.
2. Press the DONE key to move on to Screen 2: Selecting Transmitters.
Setup Mode – Screen 2 is where you will set the console to recognize signals
on that ID as coming from a Soil Moisture Station.
3. Press the LEFT or RIGHT arrow key, or the STATION key, to scroll through transmitter
IDs.
When you see the ID you chose for the Soil Moisture Station, use the UP or
DOWN arrow keys to activate reception of that ID code. Make sure the
screen shows “ON”.
4. Press the GRAPH key to change the type of station assigned to that transmitter ID.
Press the GRAPH key until the word “TEMP” appears.
5. To exit Setup Mode, press and hold the DONE key.
(See the Vantage Pro User’s Manual & Setup Guide: “Setup Mode – Screen 2:
Selecting Transmitters.”)
Viewing Current Soil Moisture and Temperature
Press the TEMP key until you see “SOIL MOIST” displayed on the console
screen where the inside temperature is usually displayed. If you see SOIL
MOIST and no number, you are seeing the moisture and temperature
readings for sensor pair #1. If you continue to press the TEMP key, you will
see the readings for sensor pairs #2, #3, and #4. If no sensors are installed the
reading will be dashed out. This confirms communication between your Soil
Moisture Station and the console — go on to “Choosing a Location for the
Soil Moisture Station & Sensors” on page 6.
If You Do Not See Current Values from the Correct Station No.
First, verify that the console/receiver is powered and is not in Setup Mode (exit
Setup Mode by pressing DONE key and holding it for a moment). Then, on the
Soil Moisture Station, check that the battery is properly installed. Walk around
the room with the console, standing for a few moments in various locations to
see if you are picking up signals.
If you don’t see readings no matter where you stand with the console, put
the transmitter in TEST mode.
Setting the Transmitter ID
Page 5
TEST mode
DIP switch #4 on the SIM (see illustration on page 4) is the TEST DIPswitch. Switch it to the ON position using a ball-point pen or paper clip.
This puts the transmitter in Test Mode. An LED indicator light will flash each
time it transmits:
✦ The LED will immediately flash once to show that the light itself func-
tions.
✦ Then it will flash each time the transmitter broadcasts a signal, which
should be every 10 seconds.
If the LED flashes only once and then remains dark, there is a problem with
the transmitter. See “Contacting Davis Technical Support” on page 10.
If the LED flashes repeatedly but your console isn’t picking up a signal
anywhere in the room, it could be related to one of the following causes:
1. The DIP switches were not correctly set on the transmitter.
Review the procedure on page 3.
2. The ID was not correctly set on the console/receiver.
Review the procedure on page 5.
3. Reception is being disrupted by RF (radio frequency) interference.
4. There is a problem with the console/receiver.
See “Contacting Davis Technical Support” on page 10.
Note: Remember to turn the Test DIP switch OFF when you’re finished testing wireless transmission. If it is left ON, the blinking LED will reduce battery life significantly.
Choosing a Location for the Soil Moisture Station & Sensors
The Watermark soil moisture sensors should be located at root depth for best
results. Shallow rooted crops with a root depth of less than 12” may only
require one soil moisture sensor. Deeper rooted row crops, small grains, vines
and trees generally require sensors located in at least two depths. The basic
principal is that the sensors must be located within the effective root system of
the crop. Guidelines on proper depths for specific crops and conditions can be
obtained from your local farm advisor.
While not absolutely necessary for operation, we also recommend that a temperature probe be installed with each soil moisture sensor. This allows the soil
moisture sensor’s readings to be temperature compensated for better accuracy.
Range of Wireless Transmission
The range of wireless transmission depends on many factors. For the best
reception, position the transmitter shelter and your console/receiver as close
together as possible.
Page 6
Wireless Soil Moisture/ Temperature Station
Range is up to 400' (125 m) in the line of sight, under optimal conditions.
Typical range under most conditions is 100' to 200' (45 to 150 m), but this may
be reduced by walls, ceilings, trees, or foliage. Radio-frequency interference
(RF) can also reduce transmission distance. Cordless phones and ham radios
are common examples of RF interference.
A metal roof or other large metal structure can interfere with the signal
(aluminum siding, a furnace with metal ducts, and your refrigerator are
examples). Sometimes transmission between wireless units is obscured by
something you cannot identify, or by some obstacle that you can’t work
around. If necessary, consider using Wireless Repeater #7624 or #7625 to
strengthen the signal or increase the distance between the transmitter and
the console/receiver.
Testing Transmission from Proposed Location
It is very important to test reception from the proposed location before permanently mounting the Soil Moisture Station.
Place the shelter at the intended mounting site, or have someone hold it
there, so you can walk around with the console/receiver for a few minutes.
Rotating the antenna may help to improve reception.
Test wireless reception anywhere you might want to use or mount your
console/receiver now or in the future. Take your time. If you aren’t picking
up strong signals where you intend to place your console, better to move the
shelter now than after it has been mounted. Experiment.
If you have irregular terrain in the area, it may interfere with the signal. For
example, if the transmitter is mounted downhill from the console/receiver,
the ground may block a wide angle of the transmitted signal.
Testing Transmission from Proposed Location
Page 7
Mounting the Soil Moisture Station
Mounting on a Pole
1. While holding the shelter against the pole, place a U-bolt around the pole and
through the two holes on at the top of the shelter.
2. Place a flat washer, a lock washer and a hex nut on each of the bolt ends.
Hex
Lock
Flat Washer Nut
Washer
U-Bolt
Mounting Soil Moisture Station on a Pole
3. Using an adjustable wrench or 7/16" wrench, tighten the nuts.
4. Place the second U-bolt around the pole and through the two holes at the bottom of
the shelter.
Put a flat washer, a lock washer, and a hex nut on each bolt end, and tighten
the hex nuts.
Page 8
Wireless Soil Moisture/ Temperature Station
Mounting on a Vertical Surface
1. With a 3/16" (5 mm) drill bit, drill two holes approximately 2" (50 mm) apart. Use a
carpenter’s level to ensure the holes will be level.
2. Drill two more holes 7-1/32" below the upper holes.
Flat
Washer
Lag
Screw
Mounting Soil Moisture Station on a Vertical Surface
3. Insert the 1/4" x 1-1/2" lag screws through the flat washers, and through the holes at
the top of the shelter into the post.
Using an adjustable wrench or 7/16" wrench, tighten the lag screws.
4. Insert the 1/4" x 1-1/2" lag screws through the flat washers, and through the holes at
the bottom of the shelter into the post.
Using an adjustable wrench or 7/16" wrench, tighten the lag screws.
Mounting the Soil Moisture Station
Page 9
A Note on Securing Cables
To prevent fraying or cutting of cables, secure them so they will not whip
about in the wind. Secure a cable to a metal pole by wrapping electrical tape
around them both. Make sure cables are secure by placing clips or ties
approximately every 3 – 5' (1 – 1.6 m).
Cable Clip
Cable Tie
Note: Do not use metal staples or a staple gun to secure cables. Metal staples—especially when
installed with a staple gun—have a tendency to cut the cables.
Contacting Davis Technical Support
If you have questions about your Soil Moisture Station, or encounter problems
installing or operating the station, please contact Davis Technical Support.
Note: Please do not return items to the factory for repair without prior authorization.
(510) 732-7814 – Monday – Friday, 7:00 a.m. – 5:30 p.m. Pacific Time.
(510) 732-9229 – For callers outside the USA or Canada.
(510) 670-0589 – Fax .
www.davisnet.com – Copies of User Manuals are available on the “Support”
page. Watch for FAQs and other updates. Subscribe to the e-newsletter.
support@davisnet.com – E-mail to Technical Support.
info@davisnet.com – General e-mail.
Page 10
Wireless Soil Moisture/ Temperature Station
Specifications
✦ Temperature range: –40 to 140° Fahrenheit (–40 to 60° Celsius)
✦ Primary power input: Solar power – Davis solar charger
✦ Secondary (backup) power: CR-123A 3-volt lithium battery
✦ Wireless transmission frequency: 916.5 MHz
✦ 868.35 MHz for overseas version – Product # includes “XA”
✦ Transmitter ID codes: 8 user-selectable
✦ License: low power (less than 1 mW), no license required
Specifications
Page 11
FCC Part 15 Class B Registration Warning
This equipment has been tested and found to comply with the limits for a class B digital device, pursuant to Part 15 of
the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential
installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation.
If this equipment does cause harmful interference to radio or television reception, which can be determined by turning
the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following
measures:
✦ Reorient or relocate the receiving antenna.
✦ Increase the separation between the equipment and receiver.
✦ Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
✦ Consult the dealer or an experienced radio/TV technician for help.
Changes or modifications not expressly approved in writing by Davis Instruments may void the user's authority to operate this equipment.
Product Numbers: 6361
Davis Instruments Part Number: 7395.145
Wireless Soil Moisture/ Temperature Station
Draft Rev A. Manual (8/7/01)
This product complies with the essential protection requirements of the EC EMC Directive 89/336/EC.
Copyright © 2001 Davis Instruments Corp. All rights reserved.
3465 Diablo Avenue, Hayward, CA 94545-2778
510-732-9229 • Fax: 510-732-9188
E-mail: info@davisnet.com • www.davisnet.com

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.3
Linearized                      : No
Create Date                     : 2001:08:07 08:13:30-07:00
Modify Date                     : 2001:08:07 08:13:30-07:00
Page Count                      : 12
Creation Date                   : 2001:08:07 15:13:30Z
Mod Date                        : 2001:08:07 15:13:30Z
Producer                        : Acrobat Distiller 5.0 for Macintosh
Author                          : Davis
Metadata Date                   : 2001:08:07 15:13:30Z
Creator                         : Davis
Title                           : 6361 SMT Station FCC
EXIF Metadata provided by EXIF.tools
FCC ID Filing: IR2DWW6361

Navigation menu