Activity Meter 2 Tester
Quick manual
1 (7)
Table of Contents
Federal Communications Commission (FCC) Statement ......................................................................... 2
Technical data ......................................................................................................................................... 3
Reading meter serial number .................................................................................................................. 4
Batteries .................................................................................................................................................. 5
Replacing batteries .............................................................................................................................. 6
Troubleshooting ...................................................................................................................................... 7
Federal Communications Commission (FCC) Statement
Note: This device complies with Part 15 of the FCC Rules. Operation is subject to the following two
conditions: (1) this device may not cause harmful interference, and (2) this device must accept any
interference received, including interference that may cause undesired operation.
2 (7)
Technical data
Nominal voltage
Battery type
Dimensions
Weight
Ideal environment
Operating temperature*
Recommended storage temperature*
3 (7)
3V DC
AA, 2 pcs
185 x 83 x 33 mm
48 g excluding batteries
119 g including batteries
Indoor
-20 °C to +55 °C
+10 °C to +35 °C
Reading meter serial number
DeLaval Activity Meter 2 Tester allows You to read out the serial number from an Activity Meter 2
unit.
To read the number from the unit, place the AM2 in the bracket as shown in Figure 1.
Note that the AM2 unit needs to be completely inserted in the bracket as shown in Figure 1.
Figure 1
Press the button labeled with Test once. The Tester will begin to search for an AM2 unit and during
this time the following text will be displayed as in Figure 2.
Figure 2: Display during search time.
When an AM2 unit is found, its serial number is displayed as in Figure 3.
Figure 3
The format is 123 XX 45678. The activity meter ID number used in the system is the five-digit number
(45678).
When the AM2 unit has been read, it will enter a so called back-off mode and cannot be read again
for the next 5 minutes.
4 (7)
Note: The shortest interval between two readings of the same AM2 unit is 5 minutes.
The serial number will be displayed during 20 seconds and after that the tester will turn itself off. At
any time during this interval, the Test-button can be pushed again to start a test of a new AM2 unit.
If no AM2 unit is found, the following message in Figure 4 will be displayed and then the tester will
turn itself off.
Figure 4
Batteries
When the lifetime of the batteries is approaching its end, a warning message will be displayed on the
second row of the display as in Figure 5.
Figure 5
The tester will still be operational but its recommended to have spare batteries at hand.
When the battery voltage drops too low, the tester will cease to function and the following message
will be displayed as in Figure 6.
Figure 6
5 (7)
Replacing batteries
In order to replace the batteries, perform the following steps:
1. Remove two Philips screws according to picture. Be aware that there are two rubber
bushings attached to the screws. See Figure 7.
Figure 7
2. Remove the battery lid and replace the two AA batteries. Note so that the direction of the
batteries is according to the sketch inside the battery holder. See Figure 8.
Figure 8
6 (7)
Troubleshooting
No.
Symptom
Tester does not start
Display shows “AM2
not found”
Cause
No/very discharged
batteries
Electrical malfunction
No AM2 unit is
present
AM2 unit is not
inserted properly
AM2 unit is in back-off
mode
Radio interference
AM2 unit is out of
battery or faulty
Tester is faulty
7 (7)
Display shows “Low
battery”
Display shows
“Replace battery!”
Discharged batteries
Low operating
temperature
Very discharged
batteries
Action
Check batteries
Replace the tester
Insert an AM2 in the bracket and press
Test
Make sure the AM2 unit is inserted
according to Figure 1.
Let the AM2 unit rest for at least 5
minutes at a safe distance (>5 m / 17
feet) from any ID-equipment such as sort
gates, ID-readers, feeding stations, etc
and try again.
Wait 5 minutes and try again in an area
with less radio traffic
Replace the AM2 unit
Try with a couple of other AM2 units. If
not working, replace the tester
None needed immediately but batteries
will be needing replacement shortly
Move to a warmer location
Replace batteries

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : No
Page Count                      : 7
Language                        : sv-SE
Tagged PDF                      : Yes
Author                          : Henrik Jonhed
Creator                         : Microsoft® Word 2016
Create Date                     : 2016:01:27 16:50:32+01:00
Modify Date                     : 2016:01:27 16:50:32+01:00
Producer                        : Microsoft® Word 2016
EXIF Metadata provided by EXIF.tools
FCC ID Filing: UCS88620301

Navigation menu