Deister Electronic MINI RFID KEY CABINET User Manual PC Software for APR200 300
Deister Electronic GmbH RFID KEY CABINET PC Software for APR200 300
Users Manual
mini Wiring & Installation Instructions V06/05/08 proxSafe mini © Copyright 2008 by deister electronic GmbH All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted, in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise, without prior written permission of deister electronic GmbH. deister electronic GmbH reserves the right to make changes to any and all parts of this documentation without obligation to notify any person or entity of such changes. May 2008 JR/IO/BF deister electronic GmbH Hermann-Bahlsen Str. 11 30890 Barsinghausen Germany Phone: +49 (0) 51 05 - 51 61 11 Fax: +49 (0) 51 05 - 51 62 17 E-Mail: info@deister-gmbh.de Web: www.deister.com ps_mini_wi_en 29/05/08 proxSafe mini mini Contents 1. Technical data ........................................................ 4 1.1 1.2 1.3 1.3.1 1.3.2 1.4 1.5 Electrical characteristics..................................................................................4 Housing .......................................................................................................4 Customer interfaces .......................................................................................5 Communication ............................................................................................5 Power...........................................................................................................6 Relay............................................................................................................6 Battery..........................................................................................................7 2. Wiring diagram ...................................................... 7 2.1 2.2 2.3 Signalisation .................................................................................................7 Configuration ...............................................................................................7 Air interface ..................................................................................................7 3. General .................................................................. 8 4. Implementing hints ................................................ 9 5. Shutter is blocked................................................... 9 6. Emergency unlock ................................................ 10 7. Regulatory notices................................................ 13 7.1 7.2 Europe .......................................................................................................13 FCC Digital Device Limitations......................................................................13 V29/05/08 ps_mini_wi_en proxSafe mini 1. Technical data 1.1 Electrical characteristics UB: In: Imax: 1.2 12-13,8V/DC* 50mA (Standby) 2,3A (during closing or opening, if no other components activated) Housing Width: 440mm without mounting angle 484mm with mounting angle Height: 133mm Depth: 173mm keyRing Seal keyTag proxCylinder * 13,8 V needed if a battery is connected and needs to be charged 12 V if no battery charging is required. This refers to all voltages in the manual. ps_mini_wi_en 29/05/08 proxSafe mini mini 1.3 Customer interfaces Figure 1: interfaces 1.3.1 Communication RS485 deBus, 9600 Baud, 1 startbit, no parity, 1 stopbit, 8 bits RJ45 Connector Connect TERMINAL of the multiplexer to HOST (e.g. via SNG3) Pin V29/05/08 Description nc nc GND GND +UB (13ss,8V) +UB (13,8V) RS485 B RS485 A ps_mini_wi_en proxSafe mini MUX IN: Data line from previous multiplexer Pin Description nc nc GND GND +UB (13,8V) +UB (13,8V) RS485 B RS485 A MUX OUT: Data line to next multiplexer Pin Description nc nc GND GND +UB (13,8V) +UB (13,8V) RS485 B RS485 A 1.3.2 Power 3-PinConnector, green RM5 POWER IN: Power line from previous multiplexer or from power supply Pin Description nc 13,8V GND 3-Pin Connector, green RM5 POWER OUT: Power line to next multiplexer Pin 1.4 Description nc 13,8V GND Relay 3-Position Field Wiring Connector, green RM3.5 (see Figure 1) ps_mini_wi_en 29/05/08 proxSafe mini mini 1.5 Battery 2-Pin Field Wiring Connector, Battery Pin Description ACCU + GND 2. Wiring diagram The deBus supports a maximum of 32 devices. The amount of necessary power supplies is depending on the application (e.g. if shutters are used or not). In this example an SNG3 adapter is used to connect the data line to the HOST. TERMINAL MUX IN MUX MUX OUT Power supply 12-13,8V/DC, 3A POWERIN POWEROUT MUX TERMINAL Local MUX MUX IN proxSafe MUX OUT USB SN POWERIN POWEROUT HOST 2.1 Signalisation Beeper Red LED Green LED Yellow LED internal internal internal internal 2.2 Configuration Only device address is configurable (see deBus description). Possible device addresses: 0x22,0x23,0x25...0x2F,0x41...0x4F,0x51,0x52 0x21 is standard address on delivery. 2.3 Air interface Frequency: 125KHz Bitrate: 4Kbit V29/05/08 ps_mini_wi_en proxSafe mini 3. General proxSafe mini is part of a keyTag management system. With proxSafe mini you can handle up to 8 proxCylinders in one device. Connection of the proxCylinders is done by RJ45 connectors. Each proxCylinder contains of the following devices: Relay for keyTag release Coil for keyTag identification Red LED for optical signalisation End switch for detecting, if the proxCylinder is occupied • • • • UB: 13,8V/DC proxSafe has a serial interface for communication: RS485, 9600 Baud, no parity, 1 stopbit, 8 bits Protocol: deBus The following parts of the proxSafe can be controlled by the host: Beeper Yellow LED Red LED main board Red LEDs proxCylinders Relay proxCylinders Lock Motor • • • • • • • Following states are controlled by the main board: Tamper Low voltage Device alert (shutter blocked) Status lock Status cabinet (open, closed, in move or undefined) Status end switch top Status end switch bottom Voltage on antenna of the proxCylinders (only after reset or after command “Get Image”) • • • • • • • • ps_mini_wi_en 29/05/08 proxSafe mini mini 4. Implementing hints You will find the implementing hints in the debus protocol for the proxsafe mini (available on request). 5. Shutter is blocked If the terminal gives a signal to the multiplexer to close the shutter and the shutter is blocked, the multiplexer tries closing the shutter for three times. If the third attempt failed, the shutter remains in this position. The device alert flag is set (see error codes in debus protocol description). The beeper of the multiplexer is activated regularly for a short time. The beeper can be deactivated by sending a “Set Output”-command with TIM = 0x00 and StdIo = virtual beeper. The device alert flag is not influenced by this command. The device alert flag is reset by sending the “Reset Status”-command or if the next closing of the shutter succeeds. V29/05/08 ps_mini_wi_en proxSafe mini 6. Emergency unlock If normal operation failed (e.g. processor does not work) to get keys out, an emergency unlock is integrated. The components for emergency unlock are at the backside of the proxSafe mini. Jack for unlocking the shutter Pin1: GND The first step is to open the shutter. The shutter is protected against opening by hand. For this reason in case of emergency the jack (red marked in the picture above) must be connected to the emergency opening box with the 2-pole cable (enclosed) as follows in order to unlock the shutter: Pin Connection GND 12-13,8V/DC While the jack is connected and the switch of the emergency opening box is being pressed constantly, the shutter can be opened by hand using a tool (for example a screw driver). 10 ps_mini_wi_en 29/05/08 proxSafe mini mini After the shutter has been opened this way, in a second step the emergency unlock for the proxCylinders must now be activated separately as follows: Jack for emergency unlock Pin 1: GND To activate this emergency unlock, the jack (red marked in the picture above) must be connected to the emergency opening box with the 4-pole cable (enclosed) as follows: Pin Connection GND 12 -13,8V/DC 12 -13,8V/DC 12 -13,8V/DC While this jack is connected and the switch of the emergency box is being pressed constantly, all keys can be taken out. V29/05/08 ps_mini_wi_en 11 proxSafe mini Emergency-switch Battery status Emergency cable Battery charge Emergency opening box with two different cables (one 2-pole-cable and one 4-pole cable) 12 ps_mini_wi_en 29/05/08 proxSafe mini mini 7. Regulatory notices 7.1 Europe Hereby, deister electronic GmbH declares that this equipment - if used according to the instructions - is in compliance with the essential requirements and other relevant provisions of the RTTE Directive 1999/5/ EC. A complete declaration of conformity can be requested at: info@deister-gmbh.de Approved for use in all European countries. 7.2 FCC Digital Device Limitations Radio and Television Interference This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at his own expense. This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. In order to maintain compliance with FCC regulations, shielded cables must be used with this equipment. Operation with non-approved equipment or unshielded cables is likely to result in interference to radio and television reception. Caution! Changes or modifications not expressly approved by the manufacturer could void the user’s authority to operate this equipment. V29/05/08 ps_mini_wi_en 13 proxSafe mini 7.3 FCC Notice To comply with FCC part 15 rules in the United States, the system must be professionally installed to ensure compliance with the Part 15 certification. It is the responsibility of the operator and professional installer to ensure that only certified systems are deployed in the United States. The use of the system in any other combination (such as co-located antennas transmitting the same information) is expressly forbidden. 7.4 Industry Canada This Class A digital apparatus complies with Canadian ICES-003. Cet appareil numérique de la classe A est conforme à la norme NMB-003 du Canada. 14 ps_mini_wi_en 29/05/08 proxSafe mini mini Notes: V29/05/08 ps_mini_wi_en 15 proxSafe mini Notes: 16 ps_mini_wi_en 29/05/08 proxSafe mini mini Germany: deister electronic GmbH Hermann-Bahlsen Str. 11 30890 Barsinghausen Tel.: +49 (0) 51 05 - 51 61 11 Fax: +49 (0) 51 05 - 51 62 17 info@deister-gmbh.de www.deister.com Belgien & Luxemburg: deister electronic office Business Park E 19 Battelsesteenweg 455/A 2800 Mechelen Tel.: +32 (0) 15 - 28 09 68 Fax: +32 (0) 15 - 28 09 71 info@benelux.deister.com Frankreich: deister electronic france 101 rue Pierre Semard 92320 Chatillon Tel.: +33 (0) 1 47 - 35 78 78 Fax: +33 (0) 1 47 - 35 92 59 info@deister.fr Großbritannien: deister electronic (UK) Ltd. Stapleton Way, Enterprise Park Spalding, Lincolnshire PE11 3YQ Tel.: +44 (0) 1775 - 717100 Fax: +44 (0) 1775 - 717101 info@deister.co.uk Niederlande: deister electronic office Tolnasingel 3 2411 PV Bodegraven Tel.: +31 (0) 1726 - 32970 Fax: +31 (0) 1726 - 32971 info@nl.deister.com V29/05/08 Kanada: Deister Electronics Inc. 1099 Kingston Road, Suite 212 Pickering, ON L1V 1B5 Tel.: +1 905 - 837 5666 Fax: +1 905 - 837 0777 info@deister-electronic.com Japan: deister electronic Japan, LTD. Toshiba Hoshikawa Bldg. 4F 2-4 Kawabe-chô Hodogaya-ku, Yokohama-shi Kanagawa, 240-0001 Tel.: +81 (0) 45 340 1831 Fax: +81 (0) 45 340 1801 info@deister.jp USA: Deister Electronic USA, Inc. 9303 Grant Avenue Manassas, VA 20110 Tel.: +1 703 - 368 2739 Fax: +1 703 - 368 9791 info@deister.com ps_mini_wi_en 17
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No Tagged PDF : Yes XMP Toolkit : Adobe XMP Core 4.0-c316 44.253921, Sun Oct 01 2006 17:14:39 Creator Tool : Acrobat PDFMaker 8.1 für Word Modify Date : 2008:05:29 16:52:57+02:00 Create Date : 2008:05:29 16:52:32+02:00 Metadata Date : 2008:05:29 16:52:57+02:00 Producer : Acrobat Distiller 8.1.0 (Windows) Format : application/pdf Creator : Britta Busche Title : PC Software for APR200/300 Document ID : uuid:bd7dfd7e-efe8-490a-9c53-007080bfb62c Instance ID : uuid:8ada8367-d331-4a8b-ad82-e9b15a2ecb63 Company : Agrident GmbH Source Modified : D:20080529145218 Page Count : 17 Page Layout : OneColumn Author : Britta BuscheEXIF Metadata provided by EXIF.tools