Description
The GE-Interlogix-CASI Model 240 access control badge reader
is an ISO standard compliant, proximity technology badge
reader. The Model 240 reader will read ISO-14443 and ISO15693 badges and key tags. The reader’s aesthetically pleasing
contemporary design and light gray housing will complement
any decor.
Features:
•
•
•
•
•
•
•
•
•
•
•
Compatible with Micro/5 2RP and 8RP controllers (not M/5-2SRP)
Compatible with all Micro/PX(N)-2000 controllers
Sealed electronics, suitable for outdoor installation
Tamper switch protected
Reads ISO-14443 and ISO-15693 access control badges and tags
Reads badge or tag serial number, no memory sector records required
User interface: 3-LEDs and beeper
Fast field maintenance, field wiring plug
Up to 4” read range (badge type and installation conditions dependent)
4-state input supervision of door contact & REX switch: opened, closed, cut, short
Reader supervision: continuously monitored by the microcontroller
Specifications
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Mount: on single width USA or European style electrical box or directly on wall
Material: ASA plastic housing; polyurethane encapsulated electronics
Housing dimensions: 3.34 x 4.40 x 0.96 inch: (85 x 112 x 24.2 mm)
Temperature range: -13 to 140 °F /-25 to +70 °C
Power supply: 8VDC to.30 VDC @ <100 mA
Electrical protection: Reverse polarity diode protection on power lines
Data Lines: high-speed transient voltage suppressor diodes
Protection type: IP 65 (IEC 529). Suitable for outdoor installation
Frequency: 13.56 MHz
Approvals: FCC,CE-EN 300 330
Read distance: up to 2 inches ISO-14443 or up to 4 inches ISO-15693
Microcontroller firmware versions: Picture Perfect 1.7 or greater recommended
Interface: Supervised F/2F
Electrical connection: 12 position plug-in strip connector with screw terminals
Beeper: controlled by SF2F protocol
Red LED: controlled by SF2F protocol
Green LED: controlled by SF2F protocol
Yellow LED: internal controlled
RS-485 for reader firmware maintenance and configuration
Casi pn: 430177001
Page 1 of 4
GE-Interlogix-CASI
Model-240 Proximity Reader
9/17/2002
FCC Cautionary Comment
Modifications to the Model-240 reader not expressly
approved by GE-Interlogix may void the FCC approval.
Model 240 Back plate
Note: Mounting holes fit a standard US single width electrical box and standard
European electrical box hole patterns.
Installation
Page 2 of 4
GE-Interlogix-CASI
Model-240 Proximity Reader
9/17/2002
Installation Considerations
1) Installation of the Model 240 reader on metal
The table below shows the expected read range reduction when a Model 240 reader is
mounted onto a metal plate or wall.
Distance
Reading distance
No metal plate
100 %
1.78 inch (4.5 cm) use 4 Surface
100%
Mount Extension plates
1.06 inch, (2.7 cm) use 3 Surface
85 %
Mount Extension plates
0.70 inch (1.8 cm) use 2 Surface
70 %
Mount Extension plates
0.35 inch (0.9 cm) use 1 Surface
50 %
Mount Extension plate
Reader placed on metal wall
10 %
2) Installation of two Model 240 readers side by side
Read range is not affected if the center-to-center distance between two readers is equal to or
greater than 6-inches (15 cm). If the distance between the two readers is less than 6-inches
(15 cm), field interference between the two readers may result in the creation of a dead spot
in the badge read field.
Attention
Two readers may simultaneously read the same badge or tag if the distance between the two
readers is less than 12-inches (30 cm), center-to-center.
Page 3 of 4
GE-Interlogix-CASI
Model-240 Proximity Reader
9/17/2002
3) Installation of two Model 240 readers back to back
For proper operation, readers installed back-to-back must be separated by at least 3.2 inches
(8cm).
Attention
Two readers may simultaneously read the same badge or tag if the distance between the two
readers is less than 6-inches (15 cm), back-to-back.
When using two readers back-to-back on a wall that will separate the two readers by 6 inches
(15 cm) or less, a metal plate (for example aluminium, 4-inches square (10cm x 10cm) must
be placed between the readers. To obtain the maximum read range, mount each Model 240
reader onto one or more Surface Mount Extension plates. Note the impact on badge read
range performance, as discussed in manual section, “Installation Considerations” (above).
Wiring
Reader 12-position field wiring plug
10
11
12
Microcontroller
Micro control, reader beeper (option)
Ground
Power, 8VDC to 30VDC
Door Contact
Reader data
Exit Request (REX)
Green LED
Micro control, red LED (option)
RS-485-A, reader firmware maintenance
RS-485-B, reader firmware maintenance
Future
Future
Micro/5PX(N)
2RP and 8RP, see
Micro/5 manual.
DO NOT use the
Model 240 reader with
M/5-S2RP
Micro/PX-2000
Micro/PXN-2000
See micro manual
Micro/ReaderJunction Box
See manual
Reader to Micro wiring distance
The maximum reader to micro cable distance is 1,000 feet (305 meters) from the microcontroller
using 4-conductor 22AWG (0.6438mm) shielded cable.
Access Control system compatibility
The Model-240 badge reader will output a 16-digit badge identification (BID) number. As a result,
the Model-240 reader is only compatible with Picture Perfect access control systems. The Model240 reader is not compatible with Secure Perfect, Secure Perfect Enterprise Edition, SP, or SPEnterprise Edition access control systems, (12-digit BID number limitation).
Picture Perfect
A 16-digit BID format must be defined within Picture Perfect. Refer to the Picture Perfect On-line
help for assistance. In brief, go to Access / Badge Formats. Enter a suitable badge format
description, example: “16-digit BID” and define the format: “%16S” (omit the quote characters).
Page 4 of 4

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.2
Linearized                      : No
Create Date                     : 2002:09:17 09:12:50
Producer                        : Acrobat Distiller 4.0 for Windows
Modify Date                     : 2002:09:17 09:12:53+02:00
Page Count                      : 4
EXIF Metadata provided by EXIF.tools
FCC ID Filing: IXLMODEL240

Navigation menu