Deister Electronic PRD5SWH4100 Inductive Reader User Manual SWH 4100 install guide black

Deister Electronic GmbH Inductive Reader SWH 4100 install guide black

Users Manual

1Tyco CONFIDENTIALModel SWH-4100Contactless Multi-Technology125 KHz and 13.56 MHz ReaderInstallation GuideVersion A1Part Number UM-090February 2005
2Tyco CONFIDENTIALCONTENTSIntroduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  3Features  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  4Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  5Installation Considerations. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  6Wiring  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  8Installation Notes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  9Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  10Model SWH-4100 Technical Specifications . . . . . . . . . . . . . . . . . . . . . . .11FCC Digital Device Limitations  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  13UL Standards Compliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  14CE Marking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  15
3Tyco CONFIDENTIALINTRODUCTIONThe SWH-4100 Contactless reader will read Prox and Smart Cards at frequencies of both 125 kHz and 13.56 MHz. The reading capability includes, for Smart Cards, both unencrypted serial numbers and encrypted programmed sectors. Refer to Table 1 for a complete list of compatible standards and data.TABLE 1. Compatible Credential Formats - Model SWH-4100HID® 26 Bit ISO 14443A (MIFARE®) SectorHID® Corporate 1000 ISO 14443B Serial NumberHID® 36 Bit Wiegand ISO 15693 Serial NumberHID® 37 Bit Wiegand MIFARE® Sector SmartFrame®Other HID pass through formats DESFire® Serial NumberDeister Prox SmartFrame® iCLASS® Serial NumberCASI-RUSCO® Prox Lite Others - Future Expansion
4Tyco CONFIDENTIALFEATURESUniversal compatibility with most 125 kHz Prox (including all HID® Prox formats) and with all ISO 15693 and ISO 14443A credentials (badges, disk tags and key fobs). Reads both 125 kHz and 13.56 MHz credentials in the same reader.Electrical protection (reverse polarity diode protection on power lines)Data lines: high-speed transient voltage suppressor diodesIP65-rated sealed electronics for deployment in both interior and exterior environmentsIntegrated reader tamper protection
5Tyco CONFIDENTIALMOUNTINGMount the single-gang backplate (with tamper magnet installed) onto the wall.FIGURE 1. Model SWH-4100 Reader Backplate (includes tamper switch magnet)NOTEMounting holes fit standard U.S. single-width electrical box and standard European (EMEA) electrical box hole patterns.
6Tyco CONFIDENTIALMount the reader module directly to the backplate and then snap the front cover in place as indicated in Figure 2.FIGURE 2. Mounting Assembly (including 1 optional isolation spacer)INSTALLATION CONSIDERATIONSAn isolation spacer (available from Software House, part number SWH-ISOSPC) may be used to improve the read range distance when mounting the reader to a metal surface. To optimize reader range use the number of backplates as indicated in Table 2. Use of Isolation Spacers is optional and not required for non-metal mounting surfaces.
7Tyco CONFIDENTIALInstallation of two SWH-4100 readers side-by-side and back-to-backRead range is not affected if the center-to-center distance between two readers is greater than or equal to four (4) inches (101.6 mm). Two readers can simultaneously read the same badge or tag if the distance between the two readers is less than 4 inches, center-to-center. If the distance between the two readers is less than four inches, field interference between the two readers may result in a double-badge read.NOTEIf two readers are being placed back-to-back on a wall less than 4 inches thick, maximum performance can be achieved by using a metal separation plate and then using isolation spacers as necessary.TABLE 2. Isolation spacer recommendation for mounting the SWH-4100 reader on metal.Distance Reading DistanceNo metal plate 100%4.5 cm 100%2.7 cm (3 tamper plates) 85%1.8 cm (2 tamper plates) 70%0.9 cm (1 tamper plate) 50%0 cm 10%
8Tyco CONFIDENTIALWIRINGThe Model SWH-4100 has twelve terminals as noted in Table 3. The terminal strip is removable for easy installation and wiring. When attaching wires to the connector, strip off only the minimum insulation required (approx. 1/8'') and push the wire into the connector until the insulation is flush or inside the connector body. This is particularly critical for outdoor readers. While the reader itself is designed and protected to IP65 standards, the cable wires can potentially corrode and short together if not carefully mounted and tightly fastened in the connector body.TABLE 3.  Connector Pins for Model SWH-4100PIN # Description1 External Beeper Control2 Ground3 Power (8 to 16 VDC)4 D1 Wiegand5 D0 Wiegand6 Reserved for Future Use7 External Green LED Control8 External Red LED Control9 A - RS485 - used for Flash upgrade10 B - RS485 - used for Flash upgrade11 Tamper (Normally Closed)12 Tamper (Normally Closed)
9Tyco CONFIDENTIALTable 4 indicates maximum wiring distances per Wiegand standard with the three most common gauges of cable.INSTALLATION NOTESUnless otherwise specified in this manual, please follow these guidelines:1. Shielded cable is recommended in electrically noisy environments.2. You can use a local power supply for the reader. If so, don’t connect the power supply from the controller to the reader. The ground line of the local power supply must be connected to the power supply of the controller.3. The unit needs to be operated with a power source with limited power consumption according to EN 60950-1 (2003) paragraph 2.5.4. Use of a pull-up resistor may be required by some controllers. Consult your controller manual.5. For tamper wiring, connect Pins 11 and 12 to a normally closed supervised input, as shown in Figure 3.FIGURE 3. Normally Closed Wiring for Reader TamperTABLE 4. Maximum cable distance for 18, 20, or 22 AWG wireWire Gauge 18 AWG 20AWG 22 AWGCable Distance500 feet (152 meters)300 feet(91 meters)200 feet(61 meters)
10Tyco CONFIDENTIALTROUBLESHOOTINGIf the operation of a component is in doubt, substitute a known good component and retry the system. Always verify wiring against the provided wiring information before powering up the reader.TABLE 5.  Error Conditions and Possible SolutionsCondition Possible SolutionsNone of the LEDs are on.Check the following:Power connections to the reader.Reader supply voltage at connector pin 3 and that the ground connection pin 2 is secure and well connected.The door does not open and the green LED does not light when a qualified credential is presented.Verify that the door strike and the green LED are wired correctly. Verify that the access credential has been entered and that the reader has been properly configured in the host system.The green LED does not light but the door strike unlocks the door when a valid credential is presented.Verify that the door strike is wired correctly. Refer to the appropriate wiring diagram in your controller manual.Disconnect the wire from pin 7 (green LED) and connect pin 7 to pin 2 (ground). If the green LED is now on, the reader is good and the connection to the reader is defective. If the green LED does not light, replace the reader.
11Tyco CONFIDENTIALMODEL SWH-4100 TECHNICAL SPECIFICATIONSCable Recommendations:  4 core (minimum), shielded, 22 AWG (minimum) cable.Connectors:  12 position, 3.5 mm Screw Terminals - Plug-InCertifications:  FCC Part 15, CE and UL 294Open Standards Compliance:ISO 14443AISO 14443B (Depending on specific implementation)ISO 15693 (including some partially compliant credentials)Other Standards Compliance:Deister SmartFrame® in both 125 kHz and 13.56 MHz implementations HID® Prox at 125 kHz (All Formats)Standard Color:  Black (other colors available; contact your Software House representative)Dimensions with backplate (height/width/depth): 4.37" × 3.31" × 1.10" (110.99 × 84.07 × 27.94 mm)Power Supply  8-16 VDC 125 mA maximum current @ 12 VDCEnvironments:  Meets UL 294 standards for Outdoor Use.Humidity:  5 to 100% (non-condensing)Operating Temperature:  -31º F to 151º F (-35º to 67º C)
12Tyco CONFIDENTIALIndex of Protection:  IP 65 (IEC 529)Read Range:  1 to 5 inches depending on credential technology and environment.Note: Read range for credentials of identical technologies may vary greatly depending on the tuning and antenna structure of each individual credential.Standard Wiegand Output including:ID Pass-Through OptionSerial Number ReadFixed Wiegand bit stream optionSmartFrame® encrypted mifare Sector read and conversion to WiegandConsult your Software House representative for available reconfiguration cards for your reader.Upgrade Complete upgrade capability using RS485 port for reflashing of internal ROM.RS485 output option Available for compatible controllers.
13Tyco CONFIDENTIALFCC DIGITAL DEVICE LIMITATIONSRadio and Television Interference This equipment has been tested and found to comply with the limits for a digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at his own expense. This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. In order to maintain compliance with FCC regulations, shielded cables must be used with this equipment. Operation with non-approved equipment or unshielded cables is likely to result in interference to radio and television reception. Caution: Changes or modifications not expressly approved by the manufacturer could void the user’s authority to operate this equipment.
14Tyco CONFIDENTIALCANADIAN RADIO EMISSIONS REQUIREMENTSThis digital apparatus does not exceed the Class A limits for radio noise emissions from digital apparatus set out in the Radio Interference Regulations of the Canadian Department of Communications.Le present appareil numerique n'emet pas de bruits radioelectriques depassant les limites applicables aux appareils numeriques de la class A prescrites dans le Reglement sur le brouillage radioelectrique edicte par le ministere des Communications du Canada.UL STANDARDS COMPLIANCEThis reader has been tested by Underwriters Laboratories, Inc. for standard UL 294, Access Control System Units, but has not been tested for compliance with any particular model of controller.
15Tyco CONFIDENTIALCE MARKINGHereby, Software House declares that this equipment, if used according to the instructions, is in compliance with the essential requirements and other relevant provisions of the RTTE Directive 1999/5/EC. For use in all countries of the EU. A Declaration of Conformity exists for the following Software House Multi-technology readers: To obtain a copy, contact Software House and request the “Declaration of Conformity” document for Multi-technology readers.Software House70 Westview StreetLexington, MA 02421 U.S.A.In case of alteration of the product, not agreed to by us, this declaration will lose its validity.SWH-4100 SWH-2100 SWH-1100 SWH-2000SWH-5100 SWH-4200 SWH-3100SWH-1000 SWH-3000 SWH-5000This symbol indicates proof of conformity to applicable European Economic Community Council directives and harmonized standards published in the official journal of the European Communities.
Software House70 Westview StreetLexington, MA 02421http://www.swhouse.comFax: 781-466-9550 Phone: 781-466-666016Tyco CONFIDENTIALCopyrights and TrademarksThis document contains proprietary information of Tyco International, Inc. and is furnished to its customer solely to assist in the installation, testing, operation and maintenance of the equipment described. This document may not be reproduced in whole or in part without the written approval of Tyco International.Copyright 2005 Tyco InternationalAll rights reserved.Printed in Germany.Software House is a trademark of Sensormatic Electronics Corporation.  MIFARE, SmartFrame, HID, DesFire, iCLASS, and CASI-RUSCO are registered trademarks of other companies not affiliated with Sensormatic.

Navigation menu