Deister Electronic PRD5SWH4100 Inductive Reader User Manual SWH 4100 install guide black
Deister Electronic GmbH Inductive Reader SWH 4100 install guide black
Users Manual
Model SWH-4100 Contactless Multi-Technology 125 KHz and 13.56 MHz Reader Installation Guide Version A1 Part Number UM-090 February 2005 co CONTENTS Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Installation Considerations. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Installation Notes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Model SWH-4100 Technical Specifications . . . . . . . . . . . . . . . . . . . . . . .11 FCC Digital Device Limitations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 UL Standards Compliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 CE Marking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 co INTRODUCTION The SWH-4100 Contactless reader will read Prox and Smart Cards at frequencies of both 125 kHz and 13.56 MHz. The reading capability includes, for Smart Cards, both unencrypted serial numbers and encrypted programmed sectors. Refer to Table 1 for a complete list of compatible standards and data. TABLE 1. Compatible Credential Formats - Model SWH-4100 HID® 26 Bit ISO 14443A (MIFARE®) Sector HID® Corporate 1000 ISO 14443B Serial Number HID® 36 Bit Wiegand ISO 15693 Serial Number HID® 37 Bit Wiegand MIFARE® Sector SmartFrame® TNumber Other HID pass through formats DESFire® Serial Deister Prox SmartFrame® iCLASS® F Serial Number O Others - Future Expansion CASI-RUSCO® Prox Lite co FEATURES Universal compatibility with most 125 kHz Prox (including all HID® Prox formats) and with all ISO 15693 and ISO 14443A credentials (badges, disk tags and key fobs). Reads both 125 kHz and 13.56 MHz credentials in the same reader. Electrical protection (reverse polarity diode protection on power lines) Data lines: high-speed transient voltage suppressor diodes IP65-rated sealed electronics for deployment in both interior and exterior environments Integrated reader tamper protection co MOUNTING Mount the single-gang backplate (with tamper magnet installed) onto the wall. FIGURE 1. Model SWH-4100 Backplate otamper switchReader (includes magnet) Ty NOTE Mounting holes fit standard U.S. single-width electrical box and standard European (EMEA) electrical box hole patterns. Mount the reader module directly to the backplate and then snap the front cover in place as indicated in Figure 2. O Assembly FIGURE 2. C Mounting (including 1ooptional isolation spacer) INSTALLATION CONSIDERATIONS An isolation spacer (available from Software House, part number SWH-ISOSPC) may be used to improve the read range distance when mounting the reader to a metal surface. To optimize reader range use the number of backplates as indicated in Table 2. Use of Isolation Spacers is optional and not required for non-metal mounting surfaces. TABLE 2. Isolation spacer recommendation for mounting the SWH-4100 reader on metal. Distance Reading Distance No metal plate 100% 4.5 cm 100% 2.7 cm (3 tamper plates) 85% 1.8 cm (2 tamper plates) 70% 0.9 cm (1 tamper plate) 50% 0 cm 10% Installation of two SWH-4100 readers T side-by-side and back-to-back F distance between two Read range is not affected if the center-to-center readers is greater than or equal toC four (4) inches (101.6 mm). Two readers o badge or tag if the distance between the can simultaneously read the same two readers is less than T4 inches, center-to-center. If the distance between the two readers is less than four inches, field interference between the two readers may result in a double-badge read. NOTE If two readers are being placed back-to-back on a wall less than 4 inches thick, maximum performance can be achieved by using a metal separation plate and then using isolation spacers as necessary. WIRING The Model SWH-4100 has twelve terminals as noted in Table 3. The terminal strip is removable for easy installation and wiring. When attaching wires to the connector, strip off only the minimum insulation required (approx. 1/8'') and push the wire into the connector until the insulation is flush or inside the connector body. This is particularly critical for outdoor readers. While the reader itself is designed and protected to IP65 standards, the cable wires can potentially corrode and short together if not carefully mounted and tightly fastened in the connector body. TABLE 3. Connector Pins for Model SWH-4100 Ground Power (8 to 16 VDC) D1 Wiegand co D0 Wiegand Reserved for Future Use External Green LED Control External Red LED Control A - RS485 - used for Flash upgrade 10 B - RS485 - used for Flash upgrade 11 Tamper (Normally Closed) 12 Tamper (Normally Closed) PIN # Description External Beeper Control Table 4 indicates maximum wiring distances per Wiegand standard with the three most common gauges of cable. TABLE 4. Maximum cable distance for 18, 20, or 22 AWG wire Wire Gauge 18 AWG 20AWG 22 AWG Cable Distance 500 feet (152 meters) 300 feet (91 meters) 200 feet (61 meters) INSTALLATION NOTES Unless otherwise specified in this manual, please follow these guidelines: Oa power source with limited power 3. The unit needs to be operatedC with consumption according too EN 60950-1 (2003) paragraph 2.5. 4. Use of a pull-up resistor Ty may be required by some controllers. Consult 1. Shielded cable is recommended in electrically noisy environments. 2. You can use a local power supply for the reader. If so, don’t connect the power supply from the controller to the reader. The ground line of the local power supply must be connected to the power supply of the controller. your controller manual. 5. For tamper wiring, connect Pins 11 and 12 to a normally closed supervised input, as shown in Figure 3. FIGURE 3. Normally Closed Wiring for Reader Tamper TROUBLESHOOTING If the operation of a component is in doubt, substitute a known good component and retry the system. Always verify wiring against the provided wiring information before powering up the reader. TABLE 5. Error Conditions and Possible Solutions Condition Possible Solutions None of the LEDs are on. Check the following: The door does not open and the green LED does not light when a qualified credential is presented. The green LED does not light but the door strike unlocks the door when a valid credential is presented. 10 Power connections to the reader. Reader supply voltage at connector pin 3 and that the ground connection pin 2 is secure and well connected. Verify that the door strike andN the green LED are Ethe access credential wired correctly. VerifyIthat Fthat the reader has been has been entered and properly configured O in the host system. co TVerify that the door strike is wired correctly. Refer to the appropriate wiring diagram in your controller manual.Disconnect the wire from pin 7 (green LED) and connect pin 7 to pin 2 (ground). If the green LED is now on, the reader is good and the connection to the reader is defective. If the green LED does not light, replace the reader. MODEL SWH-4100 TECHNICAL SPECIFICATIONS Cable Recommendations: 4 core (minimum), shielded, 22 AWG (minimum) cable. Connectors: 12 position, 3.5 mm Screw Terminals Plug-In Certifications: FCC Part 15, CE and UL 294 Open Standards Compliance: ISO 14443A ISO 14443B (Depending on specific implementation) ISO 15693 (including some partially compliant credentials) Other Standards Deister SmartFrame® ID in both 125 kHz and Compliance: 13.56 MHzF implementations N at 125 kHz (All Formats) HID® Prox C (other colors available; contact your Standard Color: Black c Software House representative) Dimensions with backplate 4.37" × 3.31" × 1.10" (110.99 × 84.07 × (height/width/depth): 27.94 mm) Power Supply 8-16 VDC 125 mA maximum current @ 12 VDC Environments: Meets UL 294 standards for Outdoor Use. Humidity: 5 to 100% (non-condensing) Operating Temperature: -31º F to 151º F (-35º to 67º C) 11 Index of Protection: IP 65 (IEC 529) Read Range: 1 to 5 inches depending on credential technology and environment. Note: Read range for credentials of identical technologies may vary greatly depending on the tuning and antenna structure of each individual credential. Standard Wiegand Output including: ID Pass-Through Option Serial Number Read Fixed Wiegand bit stream option SmartFrame® encrypted mifare Sector read and conversion to Wiegand F capability using RS485 Upgrade Complete upgrade port O for reflashing of internal ROM. RS485 output option coAvailable for compatible controllers. Consult your Software House representative for available reconfiguration cards for your reader. 12 FCC DIGITAL DEVICE LIMITATIONS Radio and Television Interference This equipment has been tested and found to comply with the limits for a digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at his own expense. E Operation is This device complies with Part 15 of the FCC rules. subject to the following two conditions: F (1)ID This device may not cause harmful interference, and (2) this device must accept any interference ON received, including interferenceC that may cause undesired operation. co with FCC regulations, shielded cables In order to maintain compliance must be used with this equipment. Operation with non-approved equipment or unshielded cables is likely to result in interference to radio and television reception. Caution: Changes or modifications not expressly approved by the manufacturer could void the user’s authority to operate this equipment. 13 CANADIAN RADIO EMISSIONS REQUIREMENTS This digital apparatus does not exceed the Class A limits for radio noise emissions from digital apparatus set out in the Radio Interference Regulations of the Canadian Department of Communications. Le present appareil numerique n'emet pas de bruits radioelectriques depassant les limites applicables aux appareils numeriques de la class A prescrites dans le Reglement sur le brouillage radioelectrique edicte par le ministere des Communications du Canada. E Inc. for standard This reader has been tested by Underwriters Laboratories, UL 294, Access Control System Units, butF has not been tested for compliance with any particular model Oof controller. co UL STANDARDS COMPLIANCE 14 CE MARKING Hereby, Software House declares that this equipment, if used according to the instructions, is in compliance with the essential requirements and other relevant provisions of the RTTE Directive 1999/5/EC. For use in all countries of the EU. A Declaration of Conformity exists for the following Software House Multi-technology readers: SWH-4100 SWH-2100 SWH-1100 SWH-5100 SWH-4200 SWH-3100 SWH-1000 SWH-3000 SWH-5000 SWH-2000 Software House 70 Westview Street Lexington, MA 02421 U.S.A. o not agreed to by us, this declaration will In case of alteration of the c product, lose its validity. To obtain a copy, contact Software House and request the “Declaration of Conformity” document for Multi-technology readers. This symbol indicates proof of conformity to applicable European Economic Community Council directives and harmonized standards published in the official journal of the European Communities. 15 Copyrights and Trademarks This document contains proprietary information of Tyco International, Inc. and is furnished to its customer solely to assist in the installation, testing, operation and maintenance of the equipment described. This document may not be reproduced in whole or in part without the written approval of Tyco International. Copyright 2005 Tyco International All rights reserved. Printed in Germany. Software House is a trademark of Sensormatic Electronics Corporation. MIFARE, SmartFrame, HID, DesFire, iCLASS, and CASI-RUSCO are registered trademarks of other companies not affiliated with Sensormatic. co Software House 70 Westview Street Lexington, MA 02421 http://www.swhouse.com Fax: 781-466-9550 Phone: 781-466-6660 16
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.3 Linearized : No Modify Date : 2005:02:07 14:16:58Z Create Date : 2004:05:05 13:08:27Z Page Count : 16 Creation Date : 2004:05:05 13:08:27Z Mod Date : 2005:02:07 14:16:58Z Producer : Acrobat Distiller 5.0.5 (Windows) Author : lturmel Metadata Date : 2005:02:07 14:16:58Z Creator : lturmel Title : SWH-4100 install guide-black.fm Page Mode : UseOutlinesEXIF Metadata provided by EXIF.tools