Dell Networking N2000 Series Users Manual User's Guide

2015-01-05

: Dell Dell-Dell-Networking-N2000-Series-Users-Manual-136323 dell-dell-networking-n2000-series-users-manual-136323 dell pdf

Open the PDF directly: View PDF PDF.
Page Count: 1460

DownloadDell Dell-Dell-Networking-N2000-Series-Users-Manual- Networking N2000 Series User's Guide  Dell-dell-networking-n2000-series-users-manual
Open PDF In BrowserView PDF
Dell Networking
N2000, N3000, and N4000
Series Switches

User’s Configuration
Guide

Regulatory Models: N2024, N2024P,
N2038,N2048P, N3024, N3024F, N3024P,
N3048, N3048P, N4032, N4032F, N4064,
N4064F

Notes and Cautions
NOTE: A NOTE indicates important information that helps you make better use of
your computer.
CAUTION: A CAUTION indicates potential damage to hardware or loss of data if
instructions are not followed.

____________
Information in this publication is subject to change without notice.
© 2014 Dell Inc. All rights reserved.
Reproduction of these materials in any manner whatsoever without the written permission of Dell Inc.
is strictly forbidden.
Trademarks used in this text: Dell™, the DELL logo, EqualLogic™, and OpenManage™ are
trademarks of Dell Inc. Microsoft®, Windows®, Windows Server®, MS-DOS®, and Windows Vista®
are either trademarks or registered trademarks of Microsoft Corporation in the United States and/or
other countries. sFlow® is a registered trademark of InMon Corporation. Cisco® is a registered
trademark of Cisco Systems. Mozilla® and Firefox® are registered trademarks of the Mozilla
Foundation.
Other trademarks and trade names may be used in this publication to refer to either the entities claiming
the marks and names or their products. Dell Inc. disclaims any proprietary interest in trademarks and
trade names other than its own.
Regulatory Models: N2024, N2024P, N2038,N2048P, N3024, N3024F, N3024P, N3048, N3048P, N4032, N4032F, N4064, N4064F

January 2014

Rev. A01

Contents
1

Introduction .

. . . . . . . . . . . . . . . . . . . . . .

About This Document
Audience .

. . . . . . . . . . . . . . . . . .

51

. . . . . . . . . . . . . . . . . . . . . . . .

52

Document Conventions

. . . . . . . . . . . . . . . . .

Additional Documentation .

2

. . . . . . . . . . . . . . .

Switch Feature Overview
System Management Features

53

55

. . . . . . . . . . . . .

56

. . . . . . . . . .

56

. . . . . . . . . . . .

56

. . . . . . . . . . . . . . . . . . .

57

System Time Management .
Log Messages

52

. . . . . . . . . . . .

Multiple Management Options .

Integrated DHCP Server

. . . . . . . . . . . . . .
. . .

57
58

. . . . . . . . . . . . . . .

58

. . . . . . . . . . . . . . . . .

58

IPv6 Management Features
Dual Software Images
File Management .

57

. . . . . . . . . . . .

Management of Basic Network Information .

. . . .

58

. . . . . .

59

. . . . . . . . . . . . . . . . . . . . . . . .

59

Switch Database Management Templates .
Automatic Installation of Firmware and
Configuration . . . . . . . . . . . . . .
sFlow

51

SNMP Alarms and Trap Logs .

. . . . . . . . . . .

CDP Interoperability through ISDP .

60

. . . . . . . . . . . .

60

. . . . . . . . . . . . . . . . . . . .

61

Remote Monitoring (RMON)
Stacking Features

60

. . . . . . . .

High Stack Count .

. . . . . . . . . . . . . . . . .

Contents

61

3

Single IP Management

. . . . . . . . . . . . . . .

Master Failover with Transparent Transition .
Nonstop Forwarding on the Stack . . . . . .

. . .

62
62

. . . . . . . . . . .

62

. . . . . . . . . . . . . . . . . . . .

63

Hot Add/Delete and Firmware
Synchronization . . . . . . . .
Security Features

Configurable Access and Authentication
Profiles . . . . . . . . . . . . . . . . . .

63

. . . .

63

. . . . . . . . . .

63

TACACS+ Client .

. . . . . . . . . . . . . . . . . .

63

RADIUS Support

. . . . . . . . . . . . . . . . . .

64

. . . . . . . . . . . . . . . . . . . . . .

64

Strong Password Enforcement .

SSH/SSL .

Inbound Telnet Control

. . . . . . . . . . . . . . .

64

. . . . . . . . . . . . . . . . . .

64

Port Protection

. . . . . . . . . . . . . . . . . . .

64

Captive Portal .

. . . . . . . . . . . . . . . . . . .

65

Denial of Service

Dot1x Authentication (IEEE 802.1X) .

. . . . . . . .

66

MAC-Based 802.1X Authentication .

. . . . . . . .

66

. . . . . . . . . . . . . . . .

66

Dot1x Monitor Mode

MAC-Based Port Security

. . . . . . . . . . . . .

66

Access Control Lists (ACL)

. . . . . . . . . . . . .

67

. . . . . . . . . . . . . . . . .

67

Time-Based ACLs .

. . . . . . . . . . . . . .

67

. . . . . . . . . . . . . . . . . .

68

IP Source Guard (IPSG) .
DHCP Snooping .

Dynamic ARP Inspection

. . . . . . . . . . . . . .

68

. . . . . . . . . . . . . . .

69

. . . . . . . . . . . . . . . .

69

Green Technology Features
Energy Detect Mode

68

. . . . . . .

Protected Ports (Private VLAN Edge).

Energy Efficient Ethernet

. . . . . . . . . . . . . .

Power Utilization Reporting .

Contents

. . .

. . . . .

Password-Protected Management Access

4

61

. . . . . . . . . . . .

69
69

Power over Ethernet (PoE) Plus Features .
Power Over Ethernet (PoE) Plus
Configuration . . . . . . . . . .

. . . . . . . . . .

70
70

. . . . . . . . . . . . . . . . . . .

71

. . . . . . . .

71

. . . . . . . . .

71

Flow Control Support (IEEE 802.3x) .
Head of Line Blocking Prevention

. . . . . . . .

71

. . . . . . . . . . . . . .

71

Alternate Store and Forward (ASF).
Jumbo Frames Support .

Auto-MDI/MDIX Support .

. . . . . . . . . . . . .

72

. . . . . . . . . . . . . .

72

. . . . . . . . . . . . . . . . . .

72

Back Pressure Support .
Auto Negotiation

. . . . . . . . . . . . .

73

. . . . . . . . . . . . . . . . . . .

73

Broadcast Storm Control .

. . . . .

73

. . . . . . .

74

Static and Dynamic MAC Address Tables
Link Layer Discovery Protocol (LLDP)

Link Layer Discovery Protocol (LLDP) for
Media Endpoint Devices . . . . . . . . .
Connectivity Fault Management
(IEEE 802.1ag) . . . . . . . . . .

. . . . .

74

. . . . . . . . . .

74

Priority-based Flow Control (PFC)

. . . . . . . . .

Data Center Bridging Exchange (DBCx)
Protocol . . . . . . . . . . . . . . . . .

. . . . . .

75

. . . . . . . . .

75
76

. . . . . . . . . . . . . . . .

76

Cisco Protocol Filtering .
DHCP Layer 2 Relay .

74

. . . . . . . . . . . . . .

Enhanced Transmission Selection

Virtual Local Area Network Supported Features .
VLAN Support .

72

. . . . . . .

VLAN-Aware MAC-based Switching .

Port Mirroring .

70

. . . . . . . . . . . . . . . . . .

PoE Plus Support
Switching Features

. . . . . . .

. . .

77

. . . . . . . . . . . . . . . . . . .

77

Port-Based VLANs

. . . . . . . . . . . . . . . . .

IP Subnet-based VLAN .
MAC-based VLAN

77

. . . . . . . . . . . . . .

77

. . . . . . . . . . . . . . . . .

77

IEEE 802.1v Protocol-Based VLANs

. . . . . . . .

Contents

77

5

GARP and GVRP Support .
Voice VLAN

. . . . . . . . . . . . .

78

. . . . . . . . . . . . . . . . . . . . .

78

Guest VLAN .

. . . . . . . . . . . . . . . . . . . .

Double VLANs .

. . . . . . . . . . . . . . . . . . .

Spanning Tree Protocol Features

. . . . . . . . . . . .

. . . . . . . . . . . .

79

. . . . . . . . . . . . . . . .

79

Multiple Spanning Tree .

. . . . . . . . . . . . . .

79

. . . . .

80
80

RSTP-PV and STP-PV .

. . . . . . . . . . . . . . .

80

Link Aggregation Features .

. . . . . . . . . . . . . . .

81

. . . . . . . . . . . . . . . . . .

81

Bridge Protocol Data Unit (BPDU) Guard .
BPDU Filtering . . . . . . . . . . . . . .

Link Aggregation

. . . . . .

81
81

. . . . . . . . . . . . . . . . . . . .

82

Multi-Switch LAG (MLAG)
Routing Features .

Address Resolution Protocol (ARP) Table
Management . . . . . . . . . . . . . . .
VLAN Routing .

. . . . .

82

. . . . . . . . . . . . . . . . . . .

82

IP Configuration .

. . . . . . . . . . . . . . . . . .

Open Shortest Path First (OSPF)
BOOTP/DHCP Relay Agent
IP Helper and UDP Relay .

82

. . . . . . . . . .

82

. . . . . . . . . . . . .

83
83

. . . . . . . . . . . . .
. . . . . . . . . . .

83

. . . . . . . . . . . . . . . . . .

83

. . . . . . . . . . . . . . . . . . . .

83

Routing Information Protocol .
Router Discovery
Routing Table

. . . . .

. . . . . . . . . . . . .

Link Aggregate Control Protocol (LACP)

Virtual Router Redundancy Protocol (VRRP) .

. . .

84

. . . . . . . . . .

84

. . . . . . . . . . . . . . . . . .

85

Tunnel and Loopback Interfaces
IPv6 Routing Features

IPv6 Configuration

Contents

79
79

Spanning Tree Port Settings

6

78

. . . . . . . . . . .

Spanning Tree Protocol (STP)
Rapid Spanning Tree

78

. . . . . . . . . . . . . . . . .

85

IPv6 Routes .

. . . . . . . . . . . . . . . . . . . .

85

OSPFv3

. . . . . . . . . . . . . . . . . . . . . . .

85

DHCPv6

. . . . . . . . . . . . . . . . . . . . . . .

85

Quality of Service (QoS) Features .

. . . . . . . . . . .
. . . . . . . . .

86

. . . . . . . . . . . . . . .

86

Differentiated Services (DiffServ)
Class Of Service (CoS)

Auto Voice over IP (VoIP) .

. . . . . . . . . . . . .

Internet Small Computer System Interface
(iSCSI) Optimization . . . . . . . . . . . . .
Layer 2 Multicast Features

87

. . . . . . . . . . . . . . .

87

. . . . . . . . . . . . . .

87

. . . . . . . . . . . . . . . . . .

87

. . . . . . . . . . . . . .

88

. . . . . . . . . . . . . . . . . . .

88

IGMP Snooping Querier
MLD Snooping

. . . . . . . . . . .

88

. . . . . . . . . . . . . . .

89

Multicast VLAN Registration .
Layer 3 Multicast Features

. . .

89

. . . . . .

89

. . . . . . . . . . . . . . . . . . . .

89

Distance Vector Multicast Routing Protocol .
Internet Group Management Protocol .
IGMP Proxy .

Protocol Independent Multicast—
Dense Mode . . . . . . . . . . . .

. . . . . . . .

89

Protocol Independent Multicast—
Sparse Mode . . . . . . . . . . . .

. . . . . . . .

90

Protocol Independent Multicast—
Source Specific Multicast . . . . .

. . . . . . . .

90

Protocol Independent Multicast IPv6 Support .

. .

90

. . . . . . . . . .

90

. . . . . . . . . . . . . . . .

91

MLD/MLDv2 (RFC2710/RFC3810)

3

86

. . . .

MAC Multicast Support.
IGMP Snooping .

86

Hardware Overview .

Dell Networking N2000 Series Switch Hardware
N2000 Series Front Panel .

. . .

91

. . . . . . . . . . . . .

91

Contents

7

N2000 Series Back Panel .

. . . . . . . . . . . . .

N2000 LED Definitions . . . . . . . . . . . .
Power Consumption for N2000 Series PoE
Switches . . . . . . . . . . . . . . . . . .

100

. . . . . . . .

102

N3000 Series Front Panel .

. . . . . . . . . . . .

102

N3000 Series Back Panel .

. . . . . . . . . . . .

106

. . .

109

. . .

113

. . . . . . . .

115

. . . . . . . . . . . . . . . . . . . .

115

LED Definitions . . . . . . . . . . . . . . .
Power Consumption for N3000 Series PoE
Switches . . . . . . . . . . . . . . . . . .
Dell Networking N4000 Series Switch
Hardware . . . . . . . . . . . . . . . .
Front Panel

N4000 Back Panel .
LED Definitions

. . . . . . . . . . . . . . . .

119

. . . . . . . . . . . . . . . . . .

121

Switch MAC Addresses

. . . . . . . . . . . . . . . .

Using Dell OpenManage Switch
Administrator . . . . . . . . . . . . . .

. . . . . .

About Dell OpenManage Switch Administrator.
Starting the Application

. . . . . . . . . . . . . . . .

128

. . . . . . . . . . . . .

129

. . . . .

131

. . . . . . . . . . . . . . . . . . . .

132

Understanding the Device View .

. . . . . . . . . . .

Using the Device View Port Features .

Contents

127
127

Using the Switch Administrator Buttons and
Links . . . . . . . . . . . . . . . . . . . . .
Defining Fields .

125

. . .

Understanding the Interface .

8

97

. . .

Dell Networking N3000 Series Switch
Hardware . . . . . . . . . . . . . . . .

4

. . . .

95

. . . . . .

132
132

Using the Device View Switch Locator
Feature . . . . . . . . . . . . . . . . .

5

Using the Command-Line Interface .
Accessing the Switch Through the CLI

135
135

. . . . . . . . . . . . . . . .

135

. . . . . . . . . . . . . . . . .

136

Understanding Command Modes
Entering CLI Commands

. . .

. . . . . . . . .

Console Connection
Telnet Connection

133

. . . . . .

. . . . . . . . . . . .

137

. . . . . . . . . . . . . . . . .

139

. . . . . . .

139

. . . . . . . . . . . .

140

Using the Question Mark to Get Help
Using Command Completion

Entering Abbreviated Commands
Negating Commands

. . . . . . . . .

140

. . . . . . . . . . . . . . . .

140

Command Output Paging .

141

. . . . . . . . . . . . .

Understanding Error Messages

141

. . . . . . . . . .
. . .

141

. . . . . . . . . . . . . . . . . . . . . . . . . . .

142

Recalling Commands from the History Buffer

6

Default Settings .

7

Setting the IP Address and Other
Basic Network Information . . . . .

. . . . . . . . . . . . . . . . . .

. . . . .

IP Address and Network Information Overview

143

147

. . . .

147

. . . . .

147

Why Is Basic Network Information
Needed? . . . . . . . . . . . . . .

. . . . . . . .

148

How Is Basic Network Information
Configured? . . . . . . . . . . . . .

. . . . . . . .

149

What Is the Basic Network Information?

Contents

9

What Is Out-of-Band Management and
In-Band Management? . . . . . . . . .
Default Network Information

. . . . .

149

. . . . . . . . . . . . .

151

Configuring Basic Network Information (Web) .
Out-of-Band Interface

. . .

152

. . . . . . . . . . . . . .

152

IP Interface Configuration (Default VLAN IP
Address). . . . . . . . . . . . . . . . . . .

. . .

153

Route Entry Configuration (Switch Default
Gateway) . . . . . . . . . . . . . . . . . .

. . .

155

. . . . . . . . . .

157
158
159
160

Domain Name Server . . . . .
Default Domain Name . . . .
Host Name Mapping . . . . .
Dynamic Host Name Mapping

. . . . . . . . . .
. . . . . . . . . .
. . . . . . . . . .

Configuring Basic Network Information (CLI) .

. . . .
. . .

161

. . . .

161

. . . . . . . . . . . . .

162

Enabling the DHCP Client on the OOB Port .
Enabling the DHCP Client on the Default
VLAN . . . . . . . . . . . . . . . . . . .
Managing DHCP Leases

Configuring Static Network Information on
the OOB Port . . . . . . . . . . . . . . . .
Configuring Static Network Information on
the Default VLAN . . . . . . . . . . . . . .

. . .

163

. . .

163

Configuring and Viewing Additional Network
Information . . . . . . . . . . . . . . . . . .

10

Contents

161

. .

164

Basic Network Information Configuration
Example . . . . . . . . . . . . . . . . . .

8

Managing QSFP Ports

9

Managing a Switch Stack
Stacking Overview

166

. . . . . . .

. . . . . . . . . . . . . .

. . . . . . . . . . .

169
171

. . . . . . . . . . . . . . . . . . .

Dell Networking N2000, N3000, and N4000
Stacking Compatibility . . . . . . . . . . .

. . . .

174

. . . . . . . .

175

. . . . . . . . . . .

176

How is the Stack Master Selected?
Adding a Switch to the Stack .

Removing a Switch from the Stack .

. . . . . . . .
. . .

177
178

What is Nonstop Forwarding?

. . . . . . . . . . .

Switch Stack MAC Addressing and Stack
Design Considerations . . . . . . . . . . .

. . . .

181
181

. . . . . . . . . . . . .

182

. . . . . . . . . . . . . . . .

182

Why is Stacking Needed?

Managing and Monitoring the Stack (Web).

. . . . . .

184

. . . . . . . . . . . . . . . . .

184

. . . . . . . . . . . . . . . . . .

185

Unit Configuration
Stack Summary .

178

. . . . . . .

NSF Network Design Considerations

Default Stacking Values .

177

. . . . . . . . . . . .

How is the Firmware Updated on the Stack?
What is Stacking Standby? .

171

Stack Firmware Synchronization .

. . . . . . . . .

186

Supported Switches

. . . . . . . . . . . . . . . .

187

Stack Port Summary

. . . . . . . . . . . . . . . .

188

Stack Port Counters

. . . . . . . . . . . . . . . .

189

. . . . . . . . . . . . . .

189

. . . . . . . . . . . . . . . . . . .

190

Stack Port Diagnostics .
NSF Summary .

Checkpoint Statistics .

. . . . . . . . . . . . . . .

Contents

191

11

Managing the Stack (CLI)

. . . . . . . . . . . . . . .

Configuring Stack Member, Stack Port, and
NSF Settings . . . . . . . . . . . . . . . .

. . .

192

. . . . .

194

. . . . . . . . .

195

. . . . . . . . . . . . . . . . . .

195

Viewing and Clearing Stacking and NSF
Information . . . . . . . . . . . . . . .
Stacking and NSF Usage Scenarios .
Basic Failover .

Preconfiguring a Stack Member

. . . . . . . . .

NSF in the Data Center . . . . . . . . .
NSF and VoIP . . . . . . . . . . . . . .
NSF and DHCP Snooping . . . . . . . .
NSF and the Storage Access Network .
NSF and Routed Access

. . . . .

. . . . . . . . . . . . .

204

. . . . .
. . . . .
. . . . .

. . . . . . .

207

AAA Overview

. . . . . . . . . . . . . . . . . . . . .

207

Methods .

. . . . . . . . . . . . . . . . . . . . .

208

. . . . . . . . . . . . . . . . . . .

209

. . . . . . . . . . . . . . . . . . . . .

211

Access Lines
Authentication

. . . . . . . . . . . . . . .

211

. . . . . . . . . . . . . . . . . . . . .

212

Authentication Types
Authorization .

. . . . . . . . .

212

. . . . . . . . . . . . . . . . . . . . . .

214

Exec Authorization Capabilities .
Accounting .

Authentication Examples

. . . . . . . . . . . . . . .

Local Authentication Example

. . . . . . . . . .

RADIUS Authentication Example .

215
215

. . . .

217
218

. . . . . . . .

225

TACACS+ Authentication Example . . . .
Public Key SSH Authentication Example .

Contents

197
199
200
201
202

10 Configuring Authentication,
Authorization, and Accounting

12

192

. . . .

Authorization Examples

. . . . . . . . . . . . . . . . .

Local Authorization Example—Direct
Login to Privileged EXEC Mode . . . .

. . . . . . .

TACACS+ Authorization Example—Direct
Login to Privileged EXEC Mode . . . . . .
TACACS+ Authorization Example—
Administrative Profiles . . . . . . .

227

. . . . . . . .

228

. . . .

229

. . . . . . . .

230

RADIUS Authorization Example—Direct
Login to Privileged EXEC Mode . . . . . .
RADIUS Authorization Example—
Administrative Profiles . . . . . .

227

. . . . .

TACACS+ Authorization Example—Custom
Administrative Profile . . . . . . . . . . . .
TACACS+ Authorization Example—
Per-command Authorization . . . .

227

. . . . .

231

. . . . . . . . .

232

Using RADIUS Servers to Control Management
Access . . . . . . . . . . . . . . . . . . . . . .
How Does RADIUS Control Management
Access? . . . . . . . . . . . . . . . . . .

. . . .

232

. . . . .

232

Which RADIUS Attributes Does the Switch
Support? . . . . . . . . . . . . . . . . . .

. . . .

234

How Are RADIUS Attributes Processed on
the Switch? . . . . . . . . . . . . . . . . .

. . . .

236

Using TACACS+ Servers to Control Management
Access . . . . . . . . . . . . . . . . . . . . . . .

. . .

237

Which TACACS+ Attributes Does the Switch
Support? . . . . . . . . . . . . . . . . . . .

. . .

238

. . . . . . . . . . . . . . . . .

239

. . . . . . . . . . . . . . . . . . . .

239

Default Configurations .
Method Lists

Access Lines (AAA)

. . . . . . . . . . . . . . . .

Access Lines (Non-AAA) .
Administrative Profiles

239

. . . . . . . . . . . . .

240

. . . . . . . . . . . . . . .

240

Contents

13

11 Monitoring and Logging System
Information . . . . . . . . . . . . . . . .
System Monitoring Overview

. . . . . .

243

. . . . . . . . . . . . .

243

. . . .

243

. . . . . .

244

. . . . . . . .

244

What System Information Is Monitored? .
Why Is System Information Needed? .
Where Are Log Messages Sent? .

. .

245

. .

245

. . . . . . .

246

What Are the Severity Levels? . . . . . . . .
What Are the System Startup and Operation
Logs? . . . . . . . . . . . . . . . . . . . . .
What Is the Log Message Format? .

What Factors Should Be Considered When
Configuring Logging? . . . . . . . . . . . .
Default Log Settings

. . .

247

. . . . . . . . . . . . . . . . . .

248

Monitoring System Information and Configuring
Logging (Web) . . . . . . . . . . . . . . . . . .
Device Information

. . .

249

. . . . . . . . . . . . . . . .

249

. . . .

251
252
253
254
255

. . . . . . . . . . . . . . . .

257

. . . . . . . . . . . . . . . . . . . . .

258

System Health . . . . . . . . . . . . . . .
System Resources . . . . . . . . . . . .
Unit Power Usage History . . . . . . . .
Integrated Cable Test for Copper Cables .
Optical Transceiver Diagnostics . . . . .
Log Global Settings
RAM Log

Log File . . . .
Syslog Server .

. . . .
. . . .

. . . . . . . . . . . . . . . . . .
. . . . . . . . .

Email Alert Subject Configuration

262

. . . . . .

262
264

Email Alert To Address Configuration.
Email Alert Statistics

259
259

. . . . . . . .

Email Alert Mail Server Configuration

Contents

. . . .

. . . . . . . . . . . . . . . . . .

Email Alert Global Configuration

14

. . . .

. . . . . .

265

. . . . . . . . . . . . . . .

266

Monitoring System Information and Configuring
Logging (CLI) . . . . . . . . . . . . . . . . . . . .
Viewing System Information and Enabling
the Locator LED . . . . . . . . . . . . . . .

. . .

267

. . . .

267

Running Cable Diagnostics .

. . . . . . . . . . . .

268

Configuring Local Logging .
Configuring Remote Logging

. . . . . . . . . . . .
. . . . . . . . . . . .

269
270

Configuring Mail Server Settings . . . . . .
Configuring Email Alerts for Log Messages
Logging Configuration Examples

. . . .

271
272

. . . . . . . . . . . .

274

. . . . . .

274

. . . . . . . . . . . . .

276

Configuring Local and Remote Logging
Configuring Email Alerting

12 Managing General System Settings
System Settings Overview .

. . . .

. . .

. . . . . . . . . . . . . . .

Why Does System Information Need to
Be Configured? . . . . . . . . . . . . .
What Are SDM Templates? .
How Does SNTP Work?

279

. . . . . .

281

. . . . . . . . . . . .

281

. . . . . . . . .

283

. . . . . . . . . . . . . .

283

Why is the System Time Needed?

What Configuration Is Required for Plug-In
Modules? . . . . . . . . . . . . . . . . . .

. . . .

What Are the Key PoE Plus Features for the
N2024P/N2048P and N3024P/N3048P
Switches? . . . . . . . . . . . . . . . . . . .
Default General System Information

284

. . .

285

. . . . . . . . . .

286

. . .

287

. . . . . . . . . . . . . . . .

287

Configuring General System Settings (Web) .
System Information .

279

CLI Banner . . . . . . . . .
SDM Template Preference .
Clock . . . . . . . . . . . .
SNTP Global Settings . . . .

. . . . . . . . . . . .
. . . . . . . . . . . .
. . . . . . . . . . . .
. . . . . . . . . . . .

Contents

290
291
292
293

15

SNTP Authentication
SNTP Server . . . .

. . . . . . . . . . . . . . .
. . . . . . . . . . . . . . .

Summer Time Configuration
Time Zone Configuration . .

. . . . . . . . . . .
. . . . . . . . . . .

. .
. .

304

. .

305

. . . . . . . . . .

307

Configuring System Information

Viewing Slot Information (N4000 Series
Only) . . . . . . . . . . . . . . . . . . .

General System Settings Configuration
Examples . . . . . . . . . . . . . . . . .

307

. . . .

308
309

. . . .

309

. .

311

. .

312

. . . . .

313

Configuring PoE Settings (N2024P/N2048P
and N3024P/N3048P Only) . . . . . . . . .

. . .

313

. . . . . . .

315

. .

315

. . . . . . . . .
. . . . . . . . .

319
321

. . . . . . . . . . . . . . . .

323

. . . . . . . . . . . . . . . . . . . .

323

Configuring System and Banner Information .
Configuring SNTP . . . . . . . .
Configuring the Time Manually .

13 Configuring SNMP .
What Is SNMP? .
Contents

. .

. . . .

Setting the System Time and Date Manually .
Configuring the Expansion Slots (N3000
Series Only) . . . . . . . . . . . . . . . . . .

16

. .

. . . . . . . . .

Configuring the Banner . . . . . . . . . .
Managing the SDM Template . . . . . . .
Configuring SNTP Authentication and an
SNTP Server . . . . . . . . . . . . . . .

SNMP Overview

299
300
301
302
303

Card Configuration . . . . . . . . . . . . . .
Slot Summary . . . . . . . . . . . . . . . . .
Supported Cards . . . . . . . . . . . . . . .
Power Over Ethernet Global Configuration
(N2024P/N2048P and N3024P/N3048P Only) .
Power Over Ethernet Interface Configuration
(N2024P/N2048P and N3024P/N3048P Only) .
Configuring System Settings (CLI) .

294
296

. . . . . . . . . . . . . . . . .

323

What Are SNMP Traps?

. . . . . . . . . . . . . .

324

Why Is SNMP Needed?

. . . . . . . . . . . . . .

325

. . . . . . . . . . . . . . . . . .

325

Default SNMP Values

Configuring SNMP (Web)

SNMP Global Parameters

327

. . . . . . . . . . . . .

. . . . . . .

328
330
332
335
337
338

. . . . . . . . . . . . . . . . . . . . .

340

SNMP View Settings . . . . . . . . .
Access Control Group . . . . . . . .
SNMPv3 User Security Model (USM)
Communities . . . . . . . . . . . . .
Notification Filter . . . . . . . . . . .
Notification Recipients . . . . . . . .
Trap Flags .

327

. . . . . . . . . . . . . . . .

. . . . . . .
. . . . . . .
. . . . . . .
. . . . . . .
. . . . . . .

OSPFv2 Trap Flags

. . . . . . . . . . . . . . . . .

341

OSPFv3 Trap Flags

. . . . . . . . . . . . . . . . .

342

. . . . . . . . . . . . . . . . . . . . . .

343

Trap Log .

Configuring SNMP (CLI)

345

. . . . . . . . . . . . . . . . .

Configuring the SNMPv3 Engine ID
Configuring Communities .

. .

346

. . . . . . . . . . . . .

349

Configuring SNMP Notifications (Traps and
Informs) . . . . . . . . . . . . . . . . . . . .
SNMP Configuration Examples

. . .

351

. . . . . . . . . . . . .

354

. . . . . . . .

354

. . . . . . . . . . . . . . . .

355

Configuring SNMPv1 and SNMPv2.
Configuring SNMPv3

345

. . . . . . . .

Configuring SNMP Views, Groups, and Users .

14 Managing Images and Files

. . . . . . . . .

Image and File Management Overview .
What Files Can Be Managed?

359

. . . . . . . .

359

. . . . . . . . . . .

359

Why Is File Management Needed?.

. . . . . . . .

Contents

361

17

What Methods Are Supported for File
Management? . . . . . . . . . . . . .

. . . . . .

What Factors Should Be Considered When
Managing Files?. . . . . . . . . . . . . . .

. . .

364

How Is the Running Configuration Saved? .

. . .

366

. . . . . . . . . .

367

. . . . . . . . . . . . . . . . . . . .

367

Managing Images and Files (Web)
File System

Active Images . .
USB Flash Drive .
File Download . .
File Upload . . .
Copy Files . . . .

. . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . .

Managing Images and Files (CLI)

. . . . . . . . . . .

Downloading and Activating a New Image
(TFTP) . . . . . . . . . . . . . . . . . . . .

375

. . .

375

. . . . .

. . . . .

377
379
379

. . . . .

380

. . . . .

Managing Configuration Scripts (SFTP)
File and Image Management Configuration
Examples . . . . . . . . . . . . . . . . . . .

. . . . .

381

. . . . . . . . . . . . .

381

Managing Configuration Scripts

. . . . . . . . .

Managing Files by Using the USB Flash
Drive . . . . . . . . . . . . . . . . . . .

. . . . .

15 Automatically Updating the Image
and Configuration . . . . . . . . . . . . .
Auto Configuration Overview

384
386

. . . .

389

. . . . . . . . . . . . .

389

What Is USB Auto Configuration?

. . . . . . . .

What Files Does USB Auto Configuration
Use? . . . . . . . . . . . . . . . . . . . .
Contents

368
369
370
372
374

Managing Files in Internal Flash . . . .
Managing Files on a USB Flash Device
Uploading a Configuration File (SCP) . .

Upgrading the Firmware

18

363

. . . .

390
390

How Does USB Auto Configuration Use the
Files on the USB Device? . . . . . . . . . .
What Is the Setup File Format? .

. . . .

391

. . . . . . . . . .

392

What Is the DHCP Auto Configuration
Process? . . . . . . . . . . . . . . .

. . .

399

. . . . . . . . . . .

400

Managing Auto Configuration (Web)
Auto-Install Configuration

398

. . . .

What Are the Dependencies for DHCP Auto
Configuration? . . . . . . . . . . . . . . . .
Default Auto Configuration Values

393

. . . . . . .

Monitoring and Completing the DHCP Auto
Configuration Process . . . . . . . . . . .

. . . . . . . . . .

401

. . . . . . . . . . . . .

401

Managing Auto Configuration (CLI)

. . . . . . . . . . .

402

Managing Auto Configuration

. . . . . . . . . . .

402

. . . . . . . . . . . . . .

403

Auto Configuration Example .

Enabling USB Auto Configuration and Auto
Image Download . . . . . . . . . . . . . .

Enabling DHCP Auto Configuration and Auto
Image Download . . . . . . . . . . . . . . .
Easy Image Upgrade via USB

16 Monitoring Switch Traffic
Traffic Monitoring Overview

405
406

. . . . . . . . . . .

407
407

. . . . . . . . . . . .

407

. . . . . . . . . . . . . . . . . .

410

What is Port Mirroring?.

. . . . . . . . . . . . . .

Port Mirroring Behaviors .
Remote Capture.

. . .

. . . . . . . . . . .

. . . . . . . . . . . . . .

What is sFlow Technology?.
What is RMON? .

403

. . . .

411

. . . . . . . . . . . . .

412

. . . . . . . . . . . . . . . . . .

413

Why is Traffic Monitoring Needed?

. . . . . . . .

Contents

413

19

Default Traffic Monitoring Values .

. . . . . . . . . .

414

. . . . . . . . . . .

414

. . . . . . . . . . . . . .

414

Monitoring Switch Traffic (Web)
sFlow Agent Summary

sFlow Receiver Configuration .
sFlow Sampler Configuration . .
sFlow Poll Configuration . . . .
Interface Statistics . . . . . . .
Etherlike Statistics . . . . . . .
GVRP Statistics . . . . . . . . .
EAP Statistics . . . . . . . . . .
Utilization Summary . . . . . . .
Counter Summary . . . . . . . .
Switchport Statistics . . . . . .
RMON Statistics . . . . . . . .
RMON History Control Statistics
RMON History Table
RMON Event Control
RMON Event Log . .
RMON Alarms . . . .
Port Statistics . . . .
LAG Statistics . . . .
Port Mirroring . . . .

. . . . . . . . .
. . . . . . . . .
. . . . . . . . .
. . . . . . . . .
. . . . . . . . .
. . . . . . . . .
. . . . . . . . .
. . . . . . . . .
. . . . . . . . .
. . . . . . . . .
. . . . . . . . .
. . . . . . . . .

. . . . . . . . . . . . . . .
. . . . . . . . . . . . . . .
. . . . . . . . . . . . . . .
. . . . . . . . . . . . . . .
. . . . . . . . . . . . . . .
. . . . . . . . . . . . . . .
. . . . . . . . . . . . . . .

Monitoring Switch Traffic (CLI)

439

. . . . . . . . . . . . . . . .

439

Configuring RMON

. . . . . . . . . . . . . . . .

441

Viewing Statistics .

. . . . . . . . . . . . . . . .

443

Configuring Port Mirroring
Configuring RSPAN . . . .

. . . . . . . . . . . .
. . . . . . . . . . . .

Traffic Monitoring Configuration Examples .
Configuring sFlow .

444
445

. . . . .

447

. . . . . . . . . . . . . . . .

447

Configuring RMON . . . . .
Configuring Remote Capture
Configuring RSPAN . . . . .
Contents

429
430
432
433
435
436
437

. . . . . . . . . . . .

Configuring sFlow .

20

416
417
418
419
420
421
422
423
424
425
426
427

. . . . . . . . . . .
. . . . . . . . . . .
. . . . . . . . . . .

449
450
455

17 Configuring iSCSI Optimization .
iSCSI Optimization Overview

. . . . . .

459

. . . . . . . . . . . . . .

What Does iSCSI Optimization Do?.
How Does the Switch Detect iSCSI
Traffic Flows? . . . . . . . . . . . .

459

. . . . . . . .

460

. . . . . . . .

460

How Is Quality of Service Applied to iSCSI
Traffic Flows? . . . . . . . . . . . . . . . .
How Does iSCSI Optimization Use ACLs?

. . . .

460

. . . . .

461

What Information Does the Switch Track in
iSCSI Traffic Flows?. . . . . . . . . . . . .
How Does iSCSI Optimization Interact With
Dell EqualLogic Arrays? . . . . . . . . . .
What Occurs When iSCSI Optimization Is
Enabled or Disabled? . . . . . . . . . . . .

. . . .

462

. . . .

463

. . . .

463

How Does iSCSI Optimization Interact with
DCBx? . . . . . . . . . . . . . . . . . . . .

. . . .

464

How Does iSCSI Optimization Interact with
Dell Compellent Arrays? . . . . . . . . . .

. . . .

464

iSCSI CoS and Priority Flow Control/Enhanced
Transmission Selection Interactions . . . . . .
Default iSCSI Optimization Values

. .

465

. . . . . . . . . . .

466

Configuring iSCSI Optimization (Web)

. . . . . . . . .

467

. . . . . . . . . . . . .

467

. . . . . . . . . . . . . .

468
469
470

iSCSI Global Configuration
iSCSI Targets Table . . .
iSCSI Sessions Table . .
iSCSI Sessions Detailed

. . . . . . . . . . . . . .
. . . . . . . . . . . . . .

Configuring iSCSI Optimization (CLI)

. . . . . . . . . .

iSCSI Optimization Configuration Examples

. . . . . .

Configuring iSCSI Optimization Between
Servers and a Disk Array . . . . . . . . .

. . . . .

Contents

471
473
473

21

18 Configuring Port Characteristics .
Port Overview

. . . . .

477

. . . . . . . . . . . . . . . . . . . . .

477

What Physical Port Characteristics Can
Be Configured? . . . . . . . . . . . . .
What is Link Dependency?

. . . . .

477

. . . . . . . . . . . .

479

What Interface Types are Supported? .
What is Interface Configuration Mode?

. . . . .

481
481

What Are the Green Ethernet Features?

. . . . .

483

. . . . . . . . . . . . . . . . . .

485

Default Port Values .

Configuring Port Characteristics (Web) .
Port Configuration.

. . . . . . .

486

. . . . . . . . . . . . . . . .

486

Link Dependency Configuration
Link Dependency Summary .

. . . . . . . . .

489

. . . . . . . . . . .

491

. . . . . . . .

492

. . . . . . . . . .

493

Port Green Ethernet Configuration
Port Green Ethernet Statistics

Port Green Ethernet LPI History

. . . . . . . . .

Configuring Port Characteristics (CLI) .
Configuring Port Settings .

. . . . . . . .

496
496

. . . . . . . . .

497

. . . . . . . . . . .

498

. . . . . . . . . . . . .

500

Configuring Green Features
Port Configuration Examples

Configuring Port Settings .

. . . . . . . . . . . .

19 Configuring Port and System
Security . . . . . . . . . . . . . . . . .

501

. . . . . . . .

503

Port-based Security—IEEE 802.1X and Port
MAC Locking . . . . . . . . . . . . . . . . .

Contents

500

. . . . .

Configuring a Link Dependency Groups

22

495

. . . . . . . . . . . .

Configuring Link Dependencies

IEEE 802.1X

. . . . .

. . . . .

503

. . . . . . . . . . . . . . . . . . . .

504

Port Security (Port-MAC Locking)
Captive Portal

. . . . . . . . .

539

. . . . . . . . . . . . . . . . . . . . . .

543

Captive Portal Overview

. . .

548
550
568
574

. . . . . . . . . . . . . . . .

578

. . . . . . . . . . . . . . . . . . . . . .

578

Authentication Manager .
Overview

802.1X Interaction .

. . .
. . .

. . . . . . . . . . . . . . .

579
579

Authentication Priority

579

. . . . . . . . . . . . . . .
. . . .

580

. . . . . . . . . . . . . . . . . . . .

582

Configuration Example—802.1X and MAB .
Denial of Service

. . .

. . . . . . . . . . . . . . . . .

Authentication Restart

20 Configuring Access Control Lists
ACL Overview

543

. . . . . . . . . . . . . .

Default Captive Portal Behavior and Settings
Configuring the Captive Portal (Web) . . . .
Configuring Captive Portal (CLI) . . . . . . .
Captive Portal Configuration Example . . . .

. . . . .

583

. . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . .

584

. . . . . . . . . . . . . . . . .

585

What Are MAC ACLs?
What Are IP ACLs?

583

. . . . . . . .

585

. . . . . . . . .

585

. . . . . . . . . . . . . . . .

586

What Is the ACL Redirect Function?
What Is the ACL Mirror Function?
What Is ACL Logging

What Are Time-Based ACLs? .

. . . . . . . . . . .

What Are the ACL Limitations? .
ACL Configuration Details .

. . . . . . . . . .

587

. . . . . . . . . . . . . . .

591

. . . . . . . . . . . .

591

. . . . . . . . . . . . . . . .

591

How Are ACLs Configured? .
Editing Access Lists

586

Preventing False ACL Matches .

. . . . . . . . . .

Using IP and MAC Address Masks .

. . . . . . . .

Contents

591
593

23

Policy Based Routing
Overview

. . . . . . . . . . . . . . . . .

594

. . . . . . . . . . . . . . . . . . . . .

594

Limitations .
Examples

. . . . . . . . . . . . . . . . . . . .

596

. . . . . . . . . . . . . . . . . . . . .

598

Configuring ACLs (Web)

. . . . . . . . . . . . . . . .

IP ACL Configuration

. . . . . . . . . . . . . . .

IP ACL Rule Configuration
MAC ACL Configuration . .

. . . . . . . . . . . .
. . . . . . . . . . . .

MAC ACL Rule Configuration .
IPv6 ACL Configuration . . . .
IPv6 ACL Rule Configuration .

. . . . . . . . . .
. . . . . . . . . .
. . . . . . . . . .

ACL Binding Configuration . . .
Time Range Entry Configuration
Configuring ACLs (CLI) .

612

. . . . . . . . . . . . .

612

. . . . . . . . . . . .

. . . . . . . . . . . . .

628

. . . . . . . . . . . . . . . . . . . .

628

Advanced Examples

. . . . . . . . . . . .
. . . . . . . . . . . .

. . . . . . . . . . . . . .

629

. . . . . . . . . . . . .

629

. . . . . . . . . . . . . . .

633

Complete ACL Example .

Policy Based Routing Examples

. . . . . . . . .

640

. . . . . . . . . . . . . . . .

645

. . . . . . . . . . . . . . . . . . . .

645

21 Configuring VLANs .

. . . . . . . . . . . . . . . .

648

. . . . . . . . . . . . . . . . . .

649

. . . . . . . . . . . . . . . . . . . . . . .

650

Switchport Modes
VLAN Tagging .

Contents

. . . . . . . . .

618
623
626

Internal System ACLs .

24

605
606
607

. . . . . . . . . . . . . . . .

ACL Configuration Examples.

GVRP

601
603

609
610

Configuring a MAC ACL . .
Configuring an IPv6 ACL .
Configuring a Time Range.

VLAN Overview

599

. . . . . . . . .

Configuring an IPv4 ACL

Basic Rules

599

Double-VLAN Tagging
Voice VLAN .

. . . . . . . . . . . . . . .

651

. . . . . . . . . . . . . . . . . . . .

652

Private VLANs

. . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . .

660

. . . . . . . . . . . . . . . . .

661

Additional VLAN Features
Default VLAN Behavior

Configuring VLANs (Web)
VLAN Membership

. . . . . . . . . . . . . . . .

663

. . . . . . . . . . . . . . . . .

663

VLAN Port Settings .
VLAN LAG Settings .

. . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . .

Bind MAC to VLAN . . .
Bind IP Subnet to VLAN
GVRP Parameters.
Protocol Group . .

. . . . . . . . . . . . . .
. . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . .

Adding a Protocol Group

. . . . . . . . . . . . . .

668
669
671
672
673
675
676

. . . . . . .

678
679
681

. . . . . . . . . . . . . . . .

682

. . . . . . . . . . . . . . . . . .

682

Double VLAN Global Configuration . .
Double VLAN Interface Configuration
Voice VLAN . . . . . . . . . . . . . .
Configuring VLANs (CLI) .
Creating a VLAN

654

Configuring a Port in Access Mode
Configuring a Port in Trunk Mode

. . . . . . .

. . . . . . . .

682

. . . . . . . . .

683

. . . . . . .

686
688
689
691
692
693
695
697

. . . . . . . . . . . . .

698

Configuring a Port in General Mode .
Configuring VLAN Settings for a LAG
Configuring Double VLAN Tagging . .
Configuring MAC-Based VLANs . . .
Configuring IP-Based VLANs . . . . .
Configuring a Protocol-Based VLAN .
Configuring GVRP . . . . . . . . . . .
Configuring Voice VLANs . . . . . . .
VLAN Configuration Examples

. . . . . . .

. . . . . . .
. . . . . . .
. . . . . . .
. . . . . . .
. . . . . . .
. . . . . . .
. . . . . . .

Configuring VLANs Using Dell OpenManage
Administrator . . . . . . . . . . . . . . . . .

. . .

Contents

701

25

Configure the VLANs and Ports on Switch 2

. . .

705

. . . . . . . .

706

. . . . . . . . . . . .

710

Configuring VLANs Using the CLI .
Configuring a Voice VLAN

22 Configuring the Spanning Tree
Protocol . . . . . . . . . . . . . . . . . .
STP Overview

. . . . . . .

715

. . . . . . . . . . . . . . . . . . . . .

715

What Are Classic STP, Multiple STP, and
Rapid STP? . . . . . . . . . . . . . . . .
How Does STP Work?.

. . . .

715

. . . . . . . . . . . . . .

716

. . .

717
721
722

. . . . . . . . . . . . . . . . . . . . . . . .

724

How Does MSTP Operate in the Network? .
MSTP with Multiple Forwarding Paths . . .
What are the Optional STP Features? . . .
RSTP-PV

DirectLink Rapid Convergence

727

. . . .

729

. . . .

729

. . . . . . . . . . . . .

734

. . . . . . . . . . . . . . . . . .

735

Configuration Examples .

Configuring Spanning Tree (Web)

. . . . . . . . . . .

736

STP Global Settings .

. . . . . . . . . . . . . . .

736

STP Port Settings . .
STP LAG Settings . .
Rapid Spanning Tree

. . . . . . . . . . . . . . .

738
740
741

. . . . . . . . . . . . . . .
. . . . . . . . . . . . . . .

MSTP Settings . . . . .
MSTP Interface Settings

Contents

725

. . . .

Interoperability With IEEE Spanning Tree
Protocols . . . . . . . . . . . . . . . . .

26

. . .

. . . . . . . . . .

IndirectLink Rapid Convergence Feature .
Interoperability Between STP-PV and
RSTP-PV Modes . . . . . . . . . . . . .

Default STP Values .

. . .

. . . . . . . . . . . . .
. . . . . . . . . . . . .

743
745

Configuring Spanning Tree (CLI) .

746

. . . . . . . . . . . .
. . . . . .

746

Configuring Optional STP Features .

. . . . . . . .

747

Configuring STP Interface Settings

. . . . . . . .

748

Configuring Global STP Bridge Settings

. . . . . . .

749
750

. . . . . . . . . . . . . .

751

Configuring MSTP Switch Settings. .
Configuring MSTP Interface Settings
STP Configuration Examples

STP Configuration Example .

. . . . . . .

MSTP Configuration Example

753

. . . . . . . . . . .

RSTP-PV Access Switch Configuration
Example . . . . . . . . . . . . . . . . .

23 Discovering Network Devices .
Device Discovery Overview .

751

. . . . . . . . . . . .

756

. . . . . .

. . . . . . .

761

. . . . . . . . . . . . . .

761

What Is ISDP?

. . . . . . . . . . . . . . . . . . .

761

What is LLDP?

. . . . . . . . . . . . . . . . . . .

761

What is LLDP-MED?

. . . . . . . . . . . . . . . .

Why are Device Discovery Protocols
Needed? . . . . . . . . . . . . . . .
Default IDSP and LLDP Values

. . . . . . .

762

. . . . . . . . . . . . .

763

Configuring ISDP and LLDP (Web).

. . . . . . . . . . .

765

. . . . . . . . . . . . .

765

. . . . . . . . . . . . . . . . .

766

ISDP Global Configuration
ISDP Cache Table .

762

ISDP Interface Configuration . . . . .
ISDP Statistics . . . . . . . . . . . .
LLDP Configuration . . . . . . . . . .
LLDP Statistics . . . . . . . . . . . .
LLDP Connections . . . . . . . . . .
LLDP-MED Global Configuration . . .
LLDP-MED Interface Configuration .
LLDP-MED Local Device Information

. . . . . . .
. . . . . . .
. . . . . . .
. . . . . . .
. . . . . . .
. . . . . . .
. . . . . . .
. . . . . . .

Contents

767
768
769
771
772
774
775
776

27

LLDP-MED Remote Device Information
Configuring ISDP and LLDP (CLI)

. . . . .

776

. . . . . . . . . . .

777

Configuring Global ISDP Settings .

. . . . . . . .

Enabling ISDP on a Port . . . . . . . .
Viewing and Clearing ISDP Information
Configuring Global LLDP Settings. . .
Configuring Port-based LLDP Settings

. . . . .

. . . . . .
. . . . . .

779
779
780
781
782

. . . . . . . . .
. . . . . .

782

Configuring ISDP

. . . . . . . . . . . . . . . . .

782

Configuring LLDP

. . . . . . . . . . . . . . . . .

783

24 Configuring Port-Based Traffic
Control . . . . . . . . . . . . . . . . . . .

. . . . . . .

787

. . . . . . . . .

787

. . . . . . . . . . . . . .

788

Port-Based Traffic Control Overview
What is Flow Control? .

What is Storm Control? .

. . . . . . . . . . . . .

What are Protected Ports?

. . . . . . . . . . . .

788
789

What is Link Local Protocol Filtering?

. . . . . .

789

Default Port-Based Traffic Control Values

. . . . . .

790

Configuring Port-Based Traffic Control (Web)

. . . .

791

. . . . .

791

. . . . . . . . . .

792
794
796

Flow Control (Global Port Parameters) .
Storm Control . . . . . . . . .
Protected Port Configuration .
LLPF Configuration . . . . . .

. . . . . . . . . .
. . . . . . . . . .

Configuring Port-Based Traffic Control (CLI)

. . . . .

Configuring Flow Control and Storm Control

Contents

778
778

. . . . .

Device Discovery Configuration Examples

28

777

. . . . . . . . .

Viewing and Clearing LLDP Information
Configuring LLDP-MED Settings
Viewing LLDP-MED Information

. . . . .

. . .

798
798

Configuring Protected Ports
Configuring LLPF

. . . . . . . . . . . .

799

. . . . . . . . . . . . . . . . . .

800

Port-Based Traffic Control Configuration Example .

25 Configuring L2 Multicast Features
L2 Multicast Overview .

801

. .

. . . .

803

. . . . . . . . . . . . . . . . .

Multicast Flooding and Forwarding

. . . . . . . .

803

. . . .

804

. . . . . . . . . . .

804

. . . . . . . . . . . . .

805

. . . . . . . . . . . . . .

807

What Are the Multicast Bridging Features?
What Is L2 Multicast Traffic? .
What Is IGMP Snooping? .
What Is MLD Snooping?

803

What Is Multicast VLAN Registration? .

. . . . . .

809

. . . . . . . . . . .

810

. . . . . . . . . . . . .

812

What Are GARP and GMRP? .
Snooping Switch Restrictions .

808

. . . .

When Are L3 Multicast Features Required?

Partial IGMPv3 and MLDv2 Support

. . . . . . . .

MAC Address-Based Multicast Group .

. . . . . .

812
812

IGMP/MLD Snooping in a Multicast Router

. . . .

812

Topologies Where the Multicast Source Is
Not Directly Connected to the Querier . . .

. . . .

813

Using Static Multicast MAC Configuration .

. . . .

813

. . . . . . . . . . . .

813

. . . . . . . . . . . . . .

814

IGMP Snooping and GMRP .
Default L2 Multicast Values .

. . . . . . .

816

Multicast Global Parameters .

. . . . . . . . . . .

816

Bridge Multicast Group . . . .
MRouter Status . . . . . . . .
General IGMP Snooping . . .
Global Querier Configuration .
VLAN Querier . . . . . . . . .

. . . . . . . . . . .

817
820
821
824
825

Configuring L2 Multicast Features (Web) .

. . . . . . . . . . .
. . . . . . . . . . .
. . . . . . . . . . .
. . . . . . . . . . .

Contents

29

VLAN Querier Status . . . . . . . . . . . . .
MFDB IGMP Snooping Table . . . . . . . . .
MLD Snooping General . . . . . . . . . . . .
MLD Snooping Global Querier Configuration .
MLD Snooping VLAN Querier . . . . .
MLD Snooping VLAN Querier Status .
MFDB MLD Snooping Table . . . . .
MVR Global Configuration . . . . . .
MVR Members . . . . . . . . . . . .
MVR Interface Configuration . . . . .

. .
. .

. . . . . .
. . . . . .
. . . . . .
. . . . . .
. . . . . .
. . . . . .

832
834
835
836
837
838

. . . . . . . . . . . . . . . .

840
841
843

MFDB GMRP Table

. . . . . . . . . . . . . . . .

845

. . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . .

Configuring Layer 2 Multicasting .

. . . . . . .

846

. . . . . . . .

846

. . . . .

847

. . . . . . .

848

Configuring IGMP Snooping on VLANs .
Configuring IGMP Snooping Querier

Configuring MLD Snooping on VLANs

. . . . . .

849

. . . . . . .

850

. . . . . . . . . . . . . . . . .

851

Configuring MLD Snooping Querier
Configuring MVR

Configuring GARP Timers and GMRP .

. . . . . .

Case Study on a Real-World Network Topology
Multicast Snooping Case Study

Dot1ag Overview .

853

. . .

854

. . . . . . . . .

854

26 Configuring Connectivity Fault
Management . . . . . . . . . . . . . .

. . . . . . .

859

. . . . . . . . . . . . . . . . . . .

859

How Does Dot1ag Work Across a Carrier
Network? . . . . . . . . . . . . . . . . .
What Entities Make Up a Maintenance
Domain? . . . . . . . . . . . . . . . . .
Contents

. .

827
828
829
831

MVR Statistics . .
GARP Timers . . .
GMRP Parameters

Configuring L2 Multicast Features (CLI) .

30

. .

. . . .

860

. . . . .

861

What is the Administrator’s Role?
Default Dot1ag Values .

. . . . . . . . .

863

. . . . . . . . . . . . . . . . .

864

Configuring Dot1ag (Web) .

865

. . . . . . . . . . . . . . .
. . . . . . . . . . . .

865

Dot1ag MD Configuration.

. . . . . . . . . . . . .

865

Dot1ag MA Configuration.

. . . . . . . . . . . . .

866

Dot1ag MEP Configuration

. . . . . . . . . . . . .

867

Dot1ag MIP Configuration

. . . . . . . . . . . . .

868

. . . . . . . . . . . . . .

869

. . . . . . . . . . . . . . . . . . .

870

Dot1ag Global Configuration

Dot1ag RMEP Summary
Dot1ag L2 Ping

Dot1ag L2 Traceroute .
Dot1ag Statistics

870

. . . . . . . . . . . . . . .
. . . . . . . . . . .

871

. . . . . . . . . . . . . . . . . .

872

Dot1ag L2 Traceroute Cache .

Configuring Dot1ag (CLI) .

873

. . . . . . . . . . . . . . . .

Configuring Dot1ag Global Settings and
Creating Domains . . . . . . . . . . . .

. . . . . .

873

. . . . . . . . . . .

874

. . . . . . . . . . . .

875

. . . . . . . . . . . . .

876

Configuring MEP Information .
Dot1ag Ping and Traceroute
Dot1ag Configuration Example

27 Snooping and Inspecting Traffic .
Traffic Snooping and Inspection Overview .
What Is DHCP Snooping?. . . . . . .
How Is the DHCP Snooping Bindings
Database Populated? . . . . . . . . .
What Is IP Source Guard? . . . . . .
What is Dynamic ARP Inspection? . .

. . . . .

879

. . . . . .

879

. . . . . . .

880

. . . . . . .

881
883
884

. . . . . . .
. . . . . . .

Why Is Traffic Snooping and Inspection
Necessary? . . . . . . . . . . . . . . .

. . . . . .

Contents

885

31

Default Traffic Snooping and Inspection Values
Configuring Traffic Snooping and
Inspection (Web) . . . . . . . . .

. . .

885

. . . . . . . . . . .

887

DHCP Snooping Configuration

. . . . . . . . . .

DHCP Snooping Interface Configuration .
DHCP Snooping VLAN Configuration . . .
DHCP Snooping Persistent Configuration
DHCP Snooping Static Bindings
Configuration . . . . . . . . . . . . . . .
DHCP Snooping Dynamic Bindings
Summary . . . . . . . . . . . . . . . . .
DHCP Snooping Statistics . . . . . . . .
IPSG Interface Configuration . . . . . . .
IPSG Binding Configuration . . . . . . . .

. . . .

888
890
891

. . . .

892

. . . .

893
894
895
895

. . . .
. . . .

. . . .
. . . .
. . . .

. . . . . . . . . . .

896
897
898
900
901
901

. . . . . . . . . . . . . . . . . . .

902

IPSG Binding Summary . . .
DAI Global Configuration . .
DAI Interface Configuration
DAI VLAN Configuration . .
DAI ACL Configuration . . .
DAI ACL Rule Configuration .
DAI Statistics

. . . . . . . . . . .
. . . . . . . . . . .
. . . . . . . . . . .
. . . . . . . . . . .
. . . . . . . . . . .

Configuring Traffic Snooping and
Inspection (CLI). . . . . . . . . .

. . . . . . . . . . .

904

Configuring DHCP Snooping

. . . . . . . . . . .

904

Configuring IP Source Guard .

. . . . . . . . . .

Configuring Dynamic ARP Inspection

. . . . . .

Traffic Snooping and Inspection Configuration
Examples . . . . . . . . . . . . . . . . . . . . .
Configuring IPSG

Contents

906
907

. . .

910

. . . . . . . . . . .

910

. . . . . . . . . . . . . . . . .

912

Configuring DHCP Snooping

32

887

28 Configuring Link Aggregation
Link Aggregation .
Overview

. . . . . . . .

. . . . . . . . . . . . . . . . . . . .

913

. . . . . . . . . . . . . . . . . . . . . .

913

Default Link Aggregation Values .

917

. . . . . . . . .

Configuring Link Aggregation (Web) . . .
Configuring Link Aggregation (CLI) . . . .
Link Aggregation Configuration Examples

. . . . .

918
925
929

. . . . . . . . . . . . . . .

932

. . . . . . . . . . . . . . . . . . . . . .

932

Multi-Switch LAG (MLAG) .
Overview

913

Deployment Scenarios . .
Definitions . . . . . . . .
Configuration Consistency
Operation in the Network .
L2 Configuration Steps . .

. . . . . . . . . . . . .

939
942

. . . . . . . . . . . . .
. . . . . . . . . . . . .
. . . . . . .

945

. . . . . . . .

946

. . . . . . . . . . . . . .

953

Basic Configuration Example .

. . . . . . . . . . .

959

. . . . . . . . . . . . . . . .

966

29 Configuring Data Center Bridging
Features . . . . . . . . . . . . . . . . . . . .
Data Center Bridging Technology Overview

. . . .

983

. . . . . .

983

. . . . . . . . . . . . . . . .

984

. . . . . . . . . . . . . . . . . .

985

Default DCB Values .
Priority Flow Control .

933
935
936

. . . . . . . . . . . . .

Static Routing on MLAG Interfaces

A Complete Example

. . . . .

. . . . . . . . . . . . .

Switch Firmware Upgrade Procedure
Caveats and Limitations

. . . . .

PFC Operation and Behavior

. . . . . . . . . . . .

Configuring PFC Using the Web Interface

. . . . .

986

. . . . . . . . . . .

988

. . . . . . . . . . . .

990

Configuring PFC Using the CLI
PFC Configuration Example .

985

Contents

33

DCB Capability Exchange

. . . . . . . . . . . . . . .
. . . . . . . . .

993

. . . . . . . . . . . . . . .

993

Interoperability with IEEE DCBx
DCBx and Port Roles

Configuration Source Port Selection
Process . . . . . . . . . . . . . . . .
Disabling DCBX .

. . . . . .

995

. . . . . . . . . . . . . . . . .

996

Configuring DCBx .

. . . . . . . . . . . . . . . .

Enhanced Transmission Selection.

999

. . . . . . . . . . . . . . . . . .

999

. . . . . . . . . . . . . . . . . . . .

1002

. . . . . . . . . . .

1003

. . . . . . . . . . . . .

1009

ETS Configuration Example .
ETS Theory of Operation

30 Managing the MAC Address Table
MAC Address Table Overview .

. . .

. . . . . . . . . . . .

How Is the Address Table Populated?

. . . . . .

What Information Is in the MAC Address
Table? . . . . . . . . . . . . . . . . . . .

. . . .

How Is the MAC Address Table Maintained
Across a Stack? . . . . . . . . . . . . . . .
Default MAC Address Table Values

Contents

1015
1015
1015
1016

. . .

1016

. . . . . . . . . .

1016

Managing the MAC Address Table (Web) .

34

997

. . . . . . . . . .

ETS Operation .
Commands

992

. . . . . .

1017

Static Address Table

. . . . . . . . . . . . . . .

1017

Global Address Table

. . . . . . . . . . . . . . .

1019

Managing the MAC Address Table (CLI) .

. . . . . . .

1020

Managing the MAC Address Table .

. . . . . . .

1020

31 Configuring Routing Interfaces .
Routing Interface Overview .

. . . . . . . . . . . . .

. . . . . . . . .

1022

. . . . . . . . . .

1023

Why Are Routing Interfaces Needed?
Default Routing Interface Values

. . . . . .

1024

. . . . . . . . . . .

1026

Configuring Routing Interfaces (Web) .

. . . . . . . .

1027

. . . . . . . . . . . .

1027

. . . . . . . . . . . . .
. . . . . . . . . . . . .

1028
1028

. . . . . . . . . . . . . . .

1029

. . . . . . . . . . . . . . . .

1030

IP Interface Configuration
DHCP Lease Parameters
VLAN Routing Summary
Tunnel Configuration

Loopbacks Configuration .
Loopbacks Summary . . .

. . . . . . . . . . . .
. . . . . . . . . . . .

Configuring Routing Interfaces (CLI)

. . . . . . . . .

Configuring Loopback Interfaces.
Configuring Tunnels . . . . . . .

. . . . . . . .

1035
1036

. . . . . . . .

.

. . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . .

What are DHCP Options? .

. . . . . . . . . . . .

How is DHCP Option 82 Used?

1033
1033

32 Configuring DHCP Server and Relay
Settings . . . . . . . . . . . . . . . . . . . . . . .
How Does DHCP Work?

1031
1032

. .

Configuring VLAN Routing Interfaces (IPv4) .

DHCP Overview

1021
1021

What Are Loopback Interfaces?
What Are Tunnel Interfaces? .

1021

. . . . . .

What Are VLAN Routing Interfaces? .

Tunnels Summary .

. . . . .

. . . . . . . . . .

What Additional DHCP Features Does the
Switch Support? . . . . . . . . . . . . . .

. . .

1037
1037
1038
1038
1039
1041

Contents

35

Default DHCP Server Values .

. . . . . . . . . . . . .

Configuring the DHCP Server (Web) .

. . . . . . . . .
. . . . . . . .

1043
1045

Address Pool Options .
DHCP Bindings

. . . . . . . . . . . . . .

1049

. . . . . . . . . . . . . . . . . .

1051

DHCP Server Reset Configuration

. . . . . . . .

DHCP Server Conflicts Information .
DHCP Server Statistics

1052

. . . . . . . . . . . . . .

1053

. . . . . . . . . .
. . . .

1054
1055

. . . . . . . .

1056

Configuring a Dynamic Address Pool .
Configuring a Static Address Pool

Monitoring DHCP Server Information
DHCP Server Configuration Examples .

. . . . . .

1057

. . . . . . . .

1058

. . . . . .

1058

. . . . . . . .

1060

Configuring a Dynamic Address Pool .
Configuring a Static Address Pool

33 Configuring IP Routing .

. . . . . . . . . . . .

. . . . . . . . . . . . . . . . .

Default IP Routing Values

1063
1065

. . . . . . . . . . . . . . . . . . . . . . .

1066

IP Configuration .

. . . . . . . .

1067

. . . . . . . . . . . . . . . . .

1067

IP Statistics . . . . . . . . . . .
ARP Create . . . . . . . . . . .
ARP Table Configuration . . . .
Router Discovery Configuration

Contents

1063

. . . . . . . . . . . . . . .

Configuring IP Routing Features (Web)

36

1054

. . . . . .

Configuring Global DHCP Server Settings

IP Routing Overview .

1052

. . . . . . .

Configuring the DHCP Server (CLI)

ARP Table.

1043

. . . . . . . . . . . . . . . . . . .

DHCP Server Network Properties
Address Pool

1042

. . . . . . . . .
. . . . . . . . .
. . . . . . . . .
. . . . . . . . .

1068
1069
1070
1071

Router Discovery Status . . . . .
Route Table . . . . . . . . . . . .
Best Routes Table . . . . . . . .
Route Entry Configuration . . . .
Configured Routes . . . . . . . .
Route Preferences Configuration

. . . . . . . .

1072
1073
1074
1075
1077
1078

Configuring IP Routing Features (CLI) .

. . . . . . . .

1079

. . . . . . . .
. . . . . . . .
. . . . . . . .
. . . . . . . .
. . . . . . . .

Configuring Global IP Routing Settings .

. . . . .

Adding Static ARP Entries and Configuring
ARP Table Settings . . . . . . . . . . . . .
Configuring Router Discovery (IRDP) . . . .
Configuring Route Table Entries and Route
Preferences . . . . . . . . . . . . . . . . .
IP Routing Configuration Example

. . .

1080
1081

. . .

1082

. . . . . . . . . .

1084

Configuring Dell Networking Switch A .
Configuring Dell Networking Switch B .

34 Configuring L2 and L3 Relay
Features . . . . . . . . . . . . . . .
L2 and L3 Relay Overview

1079

. . .

. . . . .
. . . . .

. . . . . . . .

. . . . . . . . . . . . . . .

1085
1086

1087
1087

What Is L3 DHCP Relay?

. . . . . . . . . . . . .

1087

What Is L2 DHCP Relay?

. . . . . . . . . . . . .

1088

What Is the IP Helper Feature? .
Default L2/L3 Relay Values

. . . . . . . . .

1089

. . . . . . . . . . . . . .

1093

Configuring L2 and L3 Relay Features (Web)
DHCP Relay Global Configuration

. . . . .

1094

. . . . . . . .

1094

. . . . . .

1095
1097
1098
1098

. . . . . . . . .

1100

DHCP Relay Interface Configuration .
DHCP Relay Interface Statistics . . .
DHCP Relay VLAN Configuration . . .
DHCP Relay Agent Configuration . . .
IP Helper Global Configuration .

. . . . . .
. . . . . .
. . . . . .

Contents

37

IP Helper Interface Configuration
IP Helper Statistics . . . . . . . .

. . . . . . . .
. . . . . . . .

Configuring L2 and L3 Relay Features (CLI)
Configuring L2 DHCP Relay .

. . . . . .

1105

. . . . . . . . . . .

1105

Configuring L3 Relay (IP Helper) Settings
Relay Agent Configuration Example .

. . . .

1107

. . . . . . . . .

1109

35 Configuring OSPF and OSPFv3 .
OSPF Overview .

. . . . . .

. . . . . . . . . . . . . . . . . . . .

What Are OSPF Areas and Other OSPF
Topology Features? . . . . . . . . . . .
What Are OSPF Routers and LSAs?
How Are Routes Selected? . . . . .

. . . . .

1112
1113
1113

. . . . . . .

1113

. . . . . . . . . . . . . . . . .

1114

. . . . . . . . . . . . . . . . . . . .

1114

. . . . . . . . . . . . .

1116

. . . . . . . . . . . . . . . . . . . .

1117

Static Area Range Cost .
Flood Blocking

. . . . . . . . . . . . . . . . . .

Default OSPF Values .

. . . . . . . . . . . . . . . . .

Configuring OSPF Features (Web) .
OSPF Configuration .

Contents

1118
1120

. . . . . . . . . .

1122

. . . . . . . . . . . . . . .

1122

OSPF Area Configuration . . . .
OSPF Stub Area Summary . . .
OSPF Area Range Configuration
OSPF Interface Statistics . . . .
OSPF Interface Configuration . .
OSPF Neighbor Table . . . . . .
OSPF Neighbor Configuration .
OSPF Link State Database . . .

38

1112

. . . . . .

OSPF Feature Details.

LSA Pacing

1111

. . . . . . .

How Are OSPF and OSPFv3 Different?

Max Metric

1102
1104

. . . . . . . . .
. . . . . . . . .
. . . . . . . . .
. . . . . . . . .
. . . . . . . . .
. . . . . . . . .
. . . . . . . . .
. . . . . . . . .

1123
1126
1127
1128
1129
1130
1131
1132

OSPF Virtual Link Configuration

. . . . . . . . .

OSPF Virtual Link Summary . . . . . . . .
OSPF Route Redistribution Configuration
OSPF Route Redistribution Summary . . .
NSF OSPF Configuration . . . . . . . . .

. . . .

1134
1135
1136
1137

. . . . . . . . .

1138

. . . . . . . . . . . . . .

1138

Configuring OSPFv3 Features (Web)
OSPFv3 Configuration

1132

OSPFv3 Area Configuration .

. . . .
. . . .
. . . .

. . . . . . . . . . .

OSPFv3 Stub Area Summary . . . . . . . .
OSPFv3 Area Range Configuration . . . . .
OSPFv3 Interface Configuration . . . . . .
OSPFv3 Interface Statistics . . . . . . . .
OSPFv3 Neighbors . . . . . . . . . . . . .
OSPFv3 Neighbor Table . . . . . . . . . . .
OSPFv3 Link State Database . . . . . . . .
OSPFv3 Virtual Link Configuration . . . . .
OSPFv3 Virtual Link Summary . . . . . . .
OSPFv3 Route Redistribution Configuration
OSPFv3 Route Redistribution Summary . .
NSF OSPFv3 Configuration . . . . . . . . .
Configuring OSPF Features (CLI)

1139

. . .

1142
1143
1144
1145
1146
1147
1148
1149
1151
1152
1153
1154

. . . . . . . . . . .

1155

Configuring Global OSPF Settings

. . .
. . .
. . .
. . .
. . .
. . .
. . .
. . .
. . .

. . . . . . . .

Configuring OSPF Interface Settings .
Configuring Stub Areas and NSSAs .

. . . . . .
. . . . . .

1155
1158
1160

. . . . .

1162
1164
1166

. . . . . . . . . .

1167

Configuring Virtual Links . . . . . . . .
Configuring OSPF Area Range Settings
Configuring NSF Settings for OSPF . . .
Configuring OSPFv3 Features (CLI)

. . .
. . .

Configuring Global OSPFv3 Settings

. . . . .

. . . . . . .

Configuring OSPFv3 Interface Settings
Configuring Stub Areas and NSSAs . .
Configuring Virtual Links . . . . . .
Configuring an OSPFv3 Area Range

. . . . .

. . . . .
. . . . .

. . . . . . .
. . . . . . .

1167
1169
1171
1173
1174

Contents

39

Configuring OSPFv3 Route Redistribution
Settings . . . . . . . . . . . . . . . . . .
Configuring NSF Settings for OSPFv3 . . .
OSPF Configuration Examples .

. . . .

1175
1176

. . . . . . . . . . . .

1177

Configuring an OSPF Border Router and
Setting Interface Costs . . . . . . . . . .

. . . .

1177

. . . . .

1180

. . . . .

1184

. . . . .
. . . . .

1187
1190

. . . . . . . . . . .

1195

Configuring Stub and NSSA Areas for
OSPF and OSPFv3 . . . . . . . . . . . .
Configuring a Virtual Link for OSPF and
OSPFv3 . . . . . . . . . . . . . . . . .
Interconnecting an IPv4 Backbone and
Local IPv6 Network . . . . . . . . . . .
Configuring the Static Area Range Cost
Configuring Flood Blocking .

36 Configuring RIP
RIP Overview .

. . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . .

How Does RIP Determine Route
Information? . . . . . . . . . . .
What Is Split Horizon?

Default RIP Values

1201
1201

. . . . . . . . . . . . . .

1202

. . . . . . .

1202

. . . . . . . . . . . . . . . . . . .

1203

Configuring RIP Features (Web) .
RIP Configuration

. . . . . . . . . . .

1204

. . . . . . . . . . . . . . . . .

1204

RIP Interface Configuration . . . . . . .
RIP Interface Summary . . . . . . . . .
RIP Route Redistribution Configuration .
RIP Route Redistribution Summary . . .
Configuring RIP Features (CLI) .

. . . . .

1205
1206
1207
1208

. . . . . . . . . . . .

1209

Configuring Global RIP Settings

. . . . .
. . . . .
. . . . .

. . . . . . . . .

Configuring RIP Interface Settings

Contents

1201

. . . . . . . . .

What RIP Versions Are Supported?

40

. . . .

. . . . . . . .

1209
1210

Configuring Route Redistribution Settings .
RIP Configuration Example

37 Configuring VRRP
VRRP Overview

. . .

1211

. . . . . . . . . . . . . .

1213

. . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . .

How Does VRRP Work? .

. . . . . . . . . . . . .

What Is the VRRP Router Priority?
What Is VRRP Preemption? .

1217
1217

. . . . . . . .

1218

. . . . . . . . . . .

1218

What Is VRRP Accept Mode?

. . . . . . . . . .

What Are VRRP Route and Interface
Tracking? . . . . . . . . . . . . . . .
Default VRRP Values .

1217

1219

. . . . . .

1219

. . . . . . . . . . . . . . . . .

1221

Configuring VRRP Features (Web) .
VRRP Configuration .

. . . . . . . . . .

1222

. . . . . . . . . . . . . . .

1222

. . . . .

1223
1224
1225
1226
1228

. . . . . . . . . . .

1230

. . . . . . . . . . . .

1230

VRRP Configuration Example

. . . . . . . . . . . . .

1232

VRRP with Load Sharing

. . . . . . . . . . . . .

1232

. . . . . . . . . . . . . .

1235

VRRP Virtual Router Status . . . . . . .
VRRP Virtual Router Statistics . . . . .
VRRP Router Configuration . . . . . . .
VRRP Route Tracking Configuration . .
VRRP Interface Tracking Configuration
Configuring VRRP Features (CLI)
Configuring VRRP Settings

Troubleshooting VRRP

. . . . .
. . . . .
. . . . .
. . . . .

VRRP with Route and Interface Tracking .

. . . .

1236

Contents

41

38 Configuring IPv6 Routing .
IPv6 Routing Overview .

. . . . . . . . . .

. . . . . . . . . . . . . . . .

How Does IPv6 Compare with IPv4?

. . . . . . .

. . . . . . . . . . . . . .

1243

. . . . . .

1245

. . . . . . . . . . . . . . .

1245

Interface Configuration . . . . .
Interface Summary . . . . . . .
IPv6 Statistics . . . . . . . . . .
IPv6 Neighbor Table. . . . . . .
DHCPv6 Client Parameters . . .
DHCPv6 Client Statistics . . . .
IPv6 Router Entry Configuration
IPv6 Route Table . . . . . . . .
IPv6 Route Preferences . . . . .
Configured IPv6 Routes . . . . .

. . . . . . . . .
. . . . . . . . .
. . . . . . . . .
. . . . . . . . .
. . . . . . . . .
. . . . . . . . .
. . . . . . . . .
. . . . . . . . .
. . . . . . . . .
. . . . . . . . .

Configuring IPv6 Routing Features (CLI) .

. . . . . . .

Configuring IPv6 Interface Settings .
Configuring IPv6 Neighbor Discovery

Contents

1256

. . . . .

1256
1257
1258

. . . . . .

Configuring IPv6 Route Table Entries and
Route Preferences . . . . . . . . . . . .
IPv6 Show Commands

1246
1247
1248
1249
1250
1251
1252
1253
1254
1255

. . . . . .

Configuring Global IP Routing Settings .

42

1242
1242

Configuring IPv6 Routing Features (Web) .
Global Configuration

1241

. . . . . .

How Are IPv6 Interfaces Configured?
Default IPv6 Routing Values

1241

. . . .

1260

. . . . . . . . . . . . . .

1262

IPv6 Static Reject and Discard Routes

. . . . . . . .

39 Configuring DHCPv6 Server and
Relay Settings . . . . . . . . . . . . . .
DHCPv6 Overview

. . . . .

. . . . . . . . . . . . . . . . . . .

What Is a DHCPv6 Pool?

. . . . . . . . . . . . .

What Is a Stateless Server?

. . . . . . . . . . .

What Is the DHCPv6 Relay Agent
Information Option? . . . . . . . .
What Is a Prefix Delegation? .

1265
1266
1266

. . . . . . . .

1266
1266

. . . . . .

Configuring the DHCPv6 Server and Relay (Web) .

1267

. .

1268

. . . . . . . . . .

1268

DHCPv6 Pool Configuration . . . . .
Prefix Delegation Configuration . .
DHCPv6 Pool Summary . . . . . . .
DHCPv6 Interface Configuration . .
DHCPv6 Server Bindings Summary
DHCPv6 Statistics. . . . . . . . . .

. . . . . . .
. . . . . . .
. . . . . . .
. . . . . . .
. . . . . . .
. . . . . . .

Configuring the DHCPv6 Server and Relay (CLI)
Configuring Global DHCP Server and
Relay Agent Settings . . . . . . . . .

1269
1271
1272
1273
1275
1276

. . .

1277

. . . . . .

1277

Configuring a DHCPv6 Pool for Stateless
Server Support . . . . . . . . . . . . . .
Configuring a DHCPv6 Pool for Specific
Hosts . . . . . . . . . . . . . . . . . .

. . . .

1277

. . . . .

1278

. . .

1279

. . . . . . . . .

1280

. . . . . . . . . . .

1281

Configuring DHCPv6 Interface Information
Monitoring DHCPv6 Information
DHCPv6 Configuration Examples

1265

. . . . . . . . . .

Default DHCPv6 Server and Relay Values .

DHCPv6 Global Configuration

1263

Configuring a DHCPv6 Stateless Server

. . . . .

1281

Contents

43

Configuring the DHCPv6 Server for Prefix
Delegation . . . . . . . . . . . . . . . . .
Configuring an Interface as a DHCPv6
Relay Agent . . . . . . . . . . . . . .

. . . .

1282

. . . . . .

1283

40 Configuring Differentiated Services
DiffServ Overview

. .

. . . . . . . . . . . . . . . . . . .

How Does DiffServ Functionality Vary Based
on the Role of the Switch? . . . . . . . . . .
What Are the Elements of DiffServ
Configuration? . . . . . . . . . . . . . . . .
Default DiffServ Values

1286

. .

1286

. . . . . . . . . . . . . . . .

1287

Configuring DiffServ (Web)

. . . . . . . . . . . . . .

1288

DiffServ Configuration

. . . . . . . . . . . . . .

1288

. . . . . . . . . . . . . . .

1289
1290

. . . . . . . . . . . . . . .

. . . . . . . . . . . .

1292
1294
1297
1298
1299

. . . . . . . . . . . . . . .

1300

Policy Configuration . . .
Policy Class Definition . .
Service Configuration . . .
Service Detailed Statistics
Flow-Based Mirroring . .
Configuring DiffServ (CLI)

. . . . . . . . . . . .
. . . . . . . . . . . .
. . . . . . . . . . . .
. . . . . . . . . . . .

DiffServ Configuration (Global) .

. . . . . . . . .

1300

DiffServ Class Configuration for IPv4 .

. . . . . .

1300

DiffServ Class Configuration for IPv6 .

. . . . . .

1302

. . . . . . . . . . . . .

1303

DiffServ Policy Creation.

DiffServ Policy Attributes Configuration

. . . . .

1304

. . . . . . . . . .

1306

. . . . . . . . . . .

1307

DiffServ Service Configuration
DiffServ Configuration Examples

Providing Subnets Equal Access to
External Network . . . . . . . . . .
Contents

1285

. .

Class Configuration .
Class Criteria . . . .

44

1285

. . . . . . .

1307

DiffServ for VoIP

. . . . . . . . . . . . . . . . .

41 Configuring Class-of-Service
CoS Overview

. . . . . . .

. . . . . . . . . . . . . . . . . . . . .

What Are Trusted and Untrusted Port
Modes? . . . . . . . . . . . . . . . .

. . . . . .

How Is Traffic Shaping Used on Egress
Traffic? . . . . . . . . . . . . . . . . .

. . . . .

How Are Traffic Queues Defined? . . . .
Which Queue Management Methods Are
Supported? . . . . . . . . . . . . . . . .

1313
1313
1314
1314

. . . .

1315

. . . .

1315

. . . . . . . . . . . . . . . .

1316

. . . . . . . . . . . . . . . . . .

1316

CoS Queue Usage
Default CoS Values

1310

Configuring CoS (Web)

. . . . . . . . . . . . . . . .

Mapping Table Configuration .

. . . . . . . . . .

1318

. . . . . . .

1320
1321

. . . . . . .

1322

. . . . . . . . . . . . . . . . .

1324

Interface Configuration . . . . . . .
Interface Queue Configuration . . .
Interface Queue Drop Precedence
Configuration . . . . . . . . . . . .
Configuring CoS (CLI)

1318

Mapping Table Configuration .

. . . . . . .

. . . . . . . . . .
. . . .

1325

. . . . . . . . .

1325

CoS Interface Configuration Commands .
Interface Queue Configuration .

1324

Configuring Interface Queue Drop
Probability . . . . . . . . . . . .

. . . . . . . .

1327

Contents

45

CoS Configuration Example

42 Configuring Auto VoIP
Auto VoIP Overview

. . . . . . . . . . . . . .

. . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . .

1332

. . . . . . . . . . . . .

Auto VoIP Global Configuration .

. . . . . . . . .

Auto VoIP Interface Configuration
Configuring Auto VoIP (CLI)

1333
1333

. . . . . . . . . . . . . .

1335

. . .

. . . . . . . . . . . . . . . .

What Is IP Multicast Traffic?

. . . . . . . . . . .

What Multicast Protocols Does the Switch
Support?. . . . . . . . . . . . . . . . . . .
What Are the Multicast Protocol Roles? . .
When Is L3 Multicast Required on the
Switch? . . . . . . . . . . . . . . . .
What Is the Multicast Routing Table?

. . .
. . .

1337
1337
1338
1339
1339

. . . . . .

1340
1341

What Is IGMP?

. . . . . . . . . . . . . . . . . .

1341

What Is MLD? .

. . . . . . . . . . . . . . . . . .

1342

What Is PIM? . .
What Is DVMRP?

. . . . . .

. . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . .

Default L3 Multicast Values

Contents

1333

. . . . . . . .

43 Managing IPv4 and IPv6 Multicast

46

1331
1332

Configuring Auto VoIP (Web)

L3 Multicast Overview .

1331

. . . . . . . .

How Does Auto-VoIP Use ACLs? .
Default Auto VoIP Values

1328

. . . . . . . . . . . . . .

1343
1353
1355

Configuring General IPv4 Multicast
Features (Web) . . . . . . . . . . . .

. . . . . . . . .

1357

Multicast Global Configuration .

. . . . . . . . .

1357

Multicast Interface Configuration . . . .
Multicast Route Table . . . . . . . . . .
Multicast Admin Boundary Configuration
Multicast Admin Boundary Summary . .
Multicast Static MRoute Configuration .
Multicast Static MRoute Summary .

. . . .

1358
1359
1360
1361
1361

. . . . . . .

1362

Configuring IPv6 Multicast Features (Web) .
IPv6 Multicast Route Table .

. . . .
. . . .

1363

. . . . . . . . . . .

1363

. . . . . .

1364

. . . . . . . . . . .

1364

IGMP Interface Configuration
IGMP Interface Summary . .
IGMP Cache Information . . .

. . . . . . . . . .
. . . . . . . . . .
. . . . . . . . . .

IGMP Interface Source List Information .
IGMP Proxy Interface Configuration . . .
IGMP Proxy Configuration Summary . . .
IGMP Proxy Interface Membership Info .
Detailed IGMP Proxy Interface
Membership Information . . . . . . . . .

1365
1366
1366

. . . .

1368
1369
1370
1371

. . . .

1372

. . . . . . .

1373

. . . . . . . . . . . .

1373

Configuring MLD and MLD Proxy (Web)
MLD Global Configuration

. . . .

. . . . .

Configuring IGMP and IGMP Proxy (Web)
IGMP Global Configuration .

. . . .

. . . .
. . . .
. . . .

MLD Routing Interface Configuration . . .
MLD Routing Interface Summary. . . . . .
MLD Routing Interface Cache Information .

. . .
. . .
. . .
.

1376

. . . . . . .

. . . . . . .

1377
1378
1379

. . . . . . .

1380

. . . . . . .

1381

MLD Routing Interface Source List Information
MLD Traffic . . . . . . . . . . . . .
MLD Proxy Configuration . . . . . .
MLD Proxy Configuration Summary
MLD Proxy Interface Membership
Information . . . . . . . . . . . . .
Detailed MLD Proxy Interface
Membership Information . . . . . .

1374
1375
1375

. . . . . . .

Contents

47

Configuring PIM for IPv4 and IPv6 (Web)
PIM Global Configuration .

. . . . . . .

1382

. . . . . . . . . . . .

1382

PIM Global Status . . . . . . .
PIM Interface Configuration .
PIM Interface Summary . . .
Candidate RP Configuration .
Static RP Configuration . . . .
SSM Range Configuration . .
BSR Candidate Configuration .
BSR Candidate Summary . . .
Configuring DVMRP (Web) .

. . . . . . . . . .

1383
1384
1385
1386
1388
1390
1392
1393

. . . . . . . . . . . . . .

1394

DVMRP Global Configuration .

. . . . . . . . . .
. . . . . . . . . .
. . . . . . . . . .
. . . . . . . . . .
. . . . . . . . . .
. . . . . . . . . .
. . . . . . . . . .

. . . . . . . . . .

DVMRP Interface Configuration
DVMRP Configuration Summary
DVMRP Next Hop Summary . .
DVMRP Prune Summary . . . .
DVMRP Route Summary . . . .

. . . . . . . . .
. . . . . . . . .
. . . . . . . . .
. . . . . . . . .
. . . . . . . . .

Configuring L3 Multicast Features (CLI) .

. . . . . . .

Configuring and Viewing IPv4 Multicast
Information . . . . . . . . . . . . . . .

. . . . .

. . . . .

1401
1402
1404
1405
1406

. . . . . .

1407

. . . . .
. . . . .
. . . . .

Configuring and Viewing PIM-SM for IPv4
Multicast Routing . . . . . . . . . . . . . .
Configuring and Viewing PIM-SM for IPv6
Multicast Routing . . . . . . . . . . . . . .

Contents

1399
1399

Configuring and Viewing PIM-DM for IPv6
Multicast Routing . . . . . . . . . . . . . .

48

1395
1396
1397
1398
1398

. . . . .

Configuring and Viewing IPv6 Multicast
Route Information . . . . . . . . . . . .
Configuring and Viewing IGMP . . . . .
Configuring and Viewing IGMP Proxy .
Configuring and Viewing MLD . . . . .
Configuring and Viewing MLD Proxy . .
Configuring and Viewing PIM-DM for
IPv4 Multicast Routing . . . . . . . .

1394

. . .

1408

. . .

1410

. . .

1412

Configuring and Viewing DVMRP
Information . . . . . . . . . . . .

. . . . . . . .

1416

L3 Multicast Configuration Examples .

. . . . . . . .

1417

Configuring Multicast VLAN Routing With
IGMP and PIM-SM . . . . . . . . . . . . .
Configuring DVMRP

. . .

1417

. . . . . . . . . . . . . . .

1421

A Feature Limitations and Platform
Constants . . . . . . . . . . . . . . . . . . . . .

. . . .

1423

. . . . . . . .

1433

. . . . . . . . . . . . . . . . . . . . . . . . . . . . .

1441

B System Process Definitions
Index

Contents

49

50

Contents

1

Introduction

The switches in the Dell Networking N2000/N3000/N4000 series are stackable
Layer 2 and 3 switches that extend the Dell Networking LAN switching
product range. These switches include the following features:
•

1U form factor, rack-mountable chassis design.

•

Support for all data-communication requirements for a multi-layer switch,
including layer 2 switching, IPv4 routing, IPv6 routing, IP multicast,
quality of service, security, and system management features.

•

High availability with hot swappable stack members.

The Dell Networking N2000/N3000/N4000 includes 13 switch models:
N2024, N2024P, N2038,N2048P, N3024, N3024F, N3024P, N3048, N3048P,
N4032, N4032F, N4064, N4064F.
NOTE: Switch administrators are strongly advised to maintain Dell Networking
switches on the latest version of the Dell Networking Operating System (DNOS).
Dell Networking continually improves the features and functions of DNOS based
on feedback from you, the customer. For critical infrastructure, prestaging of the
new release into a non-critical portion of the network is recommended to verify
network configuration and operation with any new version of DNOS switch
firmware.

About This Document
This guide describes how to configure, monitor, and maintain Dell
Networking N2000/N3000/N4000 switches by using web-based Dell
OpenManage Switch Administrator utility or the command-line interface
(CLI).

Introduction

51

Audience
This guide is for network administrators in charge of managing one or more
Dell Networking series switches. To obtain the greatest benefit from this
guide, you should have a basic understanding of Ethernet networks and local
area network (LAN) concepts.

Document Conventions
Table 1-1 describes the typographical conventions this document uses.
Table 1-1.

Document Conventions

Convention

Description

Bold

Page names, field names, menu options, button names, and
CLI commands and keywords.

courier font

Command-line text (CLI output) and file names

[]

In a command line, square brackets indicate an optional
entry.

{}

In a command line, inclusive brackets indicate a selection of
compulsory parameters separated by the | character. One
option must be selected. For example: spanning-tree mode
{stp|rstp|mstp} means that for the spanning-tree mode
command you must enter either stp, rstp, or mstp

Italic

In a command line, indicates a variable.



Any individual key on the keyboard.

CTRL + Z

A keyboard combination that involves pressing the Z key
while holding the CTRL key.

52

Introduction

Additional Documentation
The following documents for the Dell Networking series switches are
available at support.dell.com/manuals:
•

Getting Started Guide—provides information about the switch models in
the series, including front and back panel features. It also describes the
installation and initial configuration procedures.

•

CLI Reference Guide—provides information about the command-line
interface (CLI) commands used to configure and manage the switch. The
document provides in-depth CLI descriptions, syntax, default values, and
usage guidelines.

Introduction

53

54

Introduction

Switch Feature Overview

2

This section describes the switch user-configurable software features.
NOTE: Before proceeding, read the release notes for this product. The release
notes are part of the firmware download.
The topics covered in this section include:
•

System Management
Features

•

Spanning Tree Protocol
Features

•

Stacking Features

•

Link Aggregation Features

•

Security Features

•

Routing Features

•

Green Technology Features

•

IPv6 Routing Features

•

Power over Ethernet (PoE)
Plus Features

•

Quality of Service (QoS)
Features

•

Switching Features

•

Layer 2 Multicast Features

•

Virtual Local Area Network
Supported Features

•

Layer 3 Multicast Features

Switch Feature Overview

55

System Management Features
Multiple Management Options
You can use any of the following methods to manage the switch:
•

Use a web browser to access the Dell OpenManage Switch Administrator
interface. The switch contains an embedded Web server that serves
HTML pages.

•

Use a Telnet client, SSH client, or a direct console connection to access
the CLI. The CLI syntax and semantics conform as much as possible to
common industry practice.

•

Use a network management system (NMS), like the Dell OpenManage
Network Manager, to manage and monitor the system through SNMP. The
switch supports SNMP v1/v2c/v3 over the UDP/IP transport protocol.

Nearly all switch features support a preconfiguration capability, even when
the feature is not enabled or the required hardware is not present.
Preconfigured capabilities become active only when enabled (typically via an
admin mode control) or when the required hardware is present (or both). For
example, a port can be preconfigured with both trunk and access mode
information. The trunk mode information is applied only when the port is
placed into trunk mode and the access mode information is only applied
when the port is placed into access mode. Likewise, OSPF routing can be
configured in the switch without being enabled on any port. This capability is
present in all of the management options.

System Time Management
You can configure the switch to obtain the system time and date through a
remote Simple Network Time Protocol (SNTP) server, or you can set the time
and date locally on the switch. You can also configure the time zone and
information about time shifts that might occur during summer months. If
you use SNTP to obtain the time, you can require communications between
the switch and the SNTP server to be encrypted.
For information about configuring system time settings, see "Managing
General System Settings" on page 279.

56

Switch Feature Overview

Log Messages
The switch maintains in-memory log messages as well as persistent logs. You
can configure remote logging so that the switch sends log messages to a
remote SYSLOG server. You can also configure the switch to email log
messages to a configured SMTP server. This allows you to receive the log
message in an e-mail account of your choice. Switch auditing messages, CLI
command logging, Web logging, and SNMP logging can be enabled or
disabled.
For information about configuring system logging, see "Monitoring and
Logging System Information" on page 243.

Integrated DHCP Server
Dell Networking series switches include an integrated DHCP server that can
deliver host-specific configuration information to hosts on the network. The
switch DHCP server allows you to configure IPv4 address pools (scopes), and
when a host’s DHCP client requests an address, the switch DHCP server
automatically assigns the host an address from the pool.
For information about configuring the DHCP server settings, see
"Configuring DHCP Server and Relay Settings" on page 1037.

Management of Basic Network Information
The DHCP client on the switch allows the switch to acquire information such
as the IPv4 or IPv6 address and default gateway from a network DHCP server.
You can also disable the DHCP client and configure static network
information. Other configurable network information includes a Domain
Name Server (DNS), hostname to IP address mapping, and a default domain
name.
If the switch detects an IP address conflict on the management interface, it
generates a trap and sends a log message.
For information about configuring basic network information, see "Setting
the IP Address and Other Basic Network Information" on page 147.

Switch Feature Overview

57

IPv6 Management Features
Dell Networking series switches provide IPv6 support for many standard
management features including HTTP, HTTPS/SSL, Telnet, SSH, SNMP,
SNTP, TFTP, and traceroute on both the in-band and out-of-band
management ports.

Dual Software Images
Dell Networking series switches can store up to two software images. The dual
image feature allows you to upgrade the switch without deleting the older
software image. You designate one image as the active image and the other
image as the backup image.
For information about managing the switch image, see "Managing Images
and Files" on page 359.

File Management
You can upload and download files such as configuration files and system
images by using HTTP (web only), TFTP, Secure FTP (SFTP), or Secure
Copy (SCP). Configuration file uploads from the switch to a server are a good
way to back up the switch configuration. You can also download a
configuration file from a server to the switch to restore the switch to the
configuration in the downloaded file.
You can also copy files to and from a USB Flash drive that is plugged into the
USB port on the front panel of the switch or automatically upgrade a switch
by booting it with a newer firmware image on a USB drive plugged in to the
switch.
For information about uploading, downloading, and copying files, see
"Managing Images and Files" on page 359.

Switch Database Management Templates
Switch Database Management (SDM) templates enable you to reallocate
system resources to support a different mix of features based on your network
requirements. Dell Networking series switches support the following three
templates:

58

•

Dual IPv4 and IPv6 (default)

•

IPv4 Routing

Switch Feature Overview

•

IPv4 Data Center

For information about setting the SDM template, see "Managing General
System Settings" on page 279.

Automatic Installation of Firmware and Configuration
The Auto Install feature allows the switch to upgrade or downgrade to a
newer software image and update the configuration file automatically during
device initialization with limited administrative configuration on the device.
If a USB device is connected to the switch and contains a firmware image
and/or configuration file, the Auto Install feature installs the image or
configuration file from USB device. Otherwise, the switch can obtain the
necessary information from a DHCP server on the network.
NOTE: Automatic migration of the startup configuration to the next version of
firmware from the current and previous versions of firmware is supported; the
syntax is automatically updated when it is read into the running-config. Check
the release notes to determine if any parts of the configuration cannot be
migrated. Save the running-config to maintain the updated syntax. Migration of
configuration is not assured on a firmware downgrade. When upgrading or
downgrading firmware, check your configuration to ensure that it implements the
desired configuration. Meta-configuration data (stack-port and slot
configuration) is always reset to the defaults on a downgrade on each stack unit.
As an example, Ethernet ports configured as stacking ports default back to
Ethernet mode on a downgrade.
For information about Auto Install, see "Automatically Updating the Image
and Configuration" on page 389.

sFlow
sFlow is the standard for monitoring high-speed switched and routed
networks. sFlow technology is built into network equipment and gives
complete visibility into network activity, enabling effective management and
control of network resources. The Dell Networking series switches support
sFlow version 5.
For information about configuring managing sFlow settings, see "Monitoring
Switch Traffic" on page 407.

Switch Feature Overview

59

SNMP Alarms and Trap Logs
The system logs events with severity codes and timestamps. The events are
sent as SNMP traps to a trap recipient list.
For information about configuring SNMP traps and alarms, see "Configuring
SNMP" on page 323.

CDP Interoperability through ISDP
Industry Standard Discovery Protocol (ISDP) allows the Dell Networking
switch to interoperate with Cisco devices running the Cisco Discovery
Protocol (CDP). ISDP is a proprietary Layer 2 network protocol which interoperates with Cisco network equipment and is used to share information
between neighboring devices (routers, bridges, access servers, and switches).
For information about configuring ISDP settings, see "Discovering Network
Devices" on page 761.

Remote Monitoring (RMON)
RMON is a standard Management Information Base (MIB) that defines
current and historical MAC-layer statistics and control objects, allowing realtime information to be captured across the entire network.
For information about configuring managing RMON settings, see
"Monitoring Switch Traffic" on page 407.

60

Switch Feature Overview

Stacking Features
For information about creating and maintaining a stack of switches, see
"Managing a Switch Stack" on page 171.

High Stack Count
The Dell Networking N2000, N3000, and N4000 series switches include a
stacking feature that allows up to 12 switches to operate as a single unit. The
N2000 and N3000 series switches have two fixed mini-SAS stacking
connectors at the rear. N2000 series switches will stack with other N2000
series switches and Dell Networking N3000 series switches stack with other
N3000 series switches.
Dell Networking N4000 series switches stack with other Dell Networking
N4000 series switches over front panel ports configured for stacking.

Single IP Management
When multiple switches are connected together through the stack ports, they
operate as a single unit with a larger port count. The stack operates and is
managed as a single entity. One switch acts as the master, and the entire stack
is managed through the management interface (Web, CLI, or SNMP) of the
stack master.

Switch Feature Overview

61

Master Failover with Transparent Transition
The stacking feature supports a standby or backup unit that assumes the

stack master role if the stack master fails. As soon as a stack master failure is
detected, the standby unit initializes the control plane and enables all other
stack units with the current configuration. The standby unit maintains a
synchronized copy of the running configuration for the stack.

Nonstop Forwarding on the Stack
The Nonstop Forwarding (NSF) feature allows the forwarding plane of stack
units to continue to forward packets while the control and management
planes restart as a result of a power failure, hardware failure, or software fault
on the stack master and allows the standby switch to quickly takeover as the
master.

Hot Add/Delete and Firmware Synchronization
You can add and remove units to and from the stack without cycling the
power. When you add a unit, the Stack Firmware Synchronization feature, if
enabled, automatically synchronizes the firmware version with the version
running on the stack master. The synchronization operation may result in
either an upgrade or a downgrade of firmware on the mismatched stack
member. Once the firmware is synchronized on a member unit, the runningconfig on the member is updated to match the master switch. The startupconfig on the standby and member switches is not updated to match the
master switch due to configuration changes on the master switch. Saving the
startup config on the master switch also saves it to the startup config on all
the other stack members.The hardware configuration of every switch is
updated to match the master switch (unit number, slot configuration, stack
member number, etc.).

62

Switch Feature Overview

Security Features
Configurable Access and Authentication Profiles
You can configure rules to limit access to the switch management interface
based on criteria such as access type and source IP address of the
management host. You can also require the user to be authenticated locally or
by an external server, such as a RADIUS server.
For information about configuring access and authentication profiles, see
"Configuring Authentication, Authorization, and Accounting" on page 207.

Password-Protected Management Access
Access to the Web, CLI, and SNMP management interfaces is password
protected, and there are no default users on the system.
For information about configuring local user accounts, see "Configuring
Authentication, Authorization, and Accounting" on page 207.

Strong Password Enforcement
The Strong Password feature enforces a baseline password strength for all
locally administered users. Password strength is a measure of the effectiveness
of a password in resisting guessing and brute-force attacks. The strength of a
password is a function of length, complexity and randomness. Using strong
passwords lowers overall risk of a security breach.
For information about configuring password settings, see "Configuring
Authentication, Authorization, and Accounting" on page 207.

TACACS+ Client
The switch has a TACACS+ client. TACACS+ provides centralized security
for validation of users accessing the switch. TACACS+ provides a centralized
user management system while still retaining consistency with RADIUS and
other authentication processes.
For information about configuring TACACS+ client settings, see
"Configuring Authentication, Authorization, and Accounting" on page 207.

Switch Feature Overview

63

RADIUS Support
The switch has a Remote Authentication Dial In User Service (RADIUS)
client and can support up to 32 named authentication and accounting
RADIUS servers. The switch also supports RADIUS Attribute 4, which is the
configuration of a NAS-IP address. You can also configure the switch to
accept RADIUS-assigned VLANs.
For information about configuring RADIUS client settings, see "Configuring
Authentication, Authorization, and Accounting" on page 207.

SSH/SSL
The switch supports Secure Shell (SSH) for secure, remote connections to
the CLI and Secure Sockets Layer (SSL) to increase security when accessing
the web-based management interface. The SSH server can be enabled or
disabled using the ip ssh command.
For information about configuring SSH and SSL settings, see "Configuring
Authentication, Authorization, and Accounting" on page 207.

Inbound Telnet Control
By default, the switch allows access over Telnet. The administrator can enable
or disable the Telnet server using the ip telnet command. Additionally, the
Telnet port number is configurable using the same command.
For information about configuring inbound Telnet settings, see "Configuring
Authentication, Authorization, and Accounting" on page 207.

Denial of Service
The switch supports configurable Denial of Service (DoS) attack protection
for eight different types of attacks.
For information about configuring DoS settings, see "Configuring Port and
System Security" on page 503.

Port Protection
A port may be put into the diagnostically disabled state for any of the
following reasons:

64

Switch Feature Overview

•

BPDU Storm Protection: By default, if Spanning Tree Protocol (STP)
bridge protocol data units (BPDUs) are received at a rate of 15pps or
greater for three consecutive seconds on a port, the port will be
diagnostically disabled. The threshold is not configurable.

•

DHCP Snooping: If DHCP packets are received on a port at a rate that
exceeds 15 pps, the port will be diagnostically disabled. The threshold is
configurable up to 300 pps for up to 15s long using the ip dhcp snooping
limit command. DHCP snooping is disabled by default. The default
protection limit is 15 pps.

•

Dynamic ARP Inspection: By default, if Dynamic ARP Inspection packets
are received on a port at a rate that exceeds 15 pps for 1 second, the port
will be diagnostically disabled. The threshold is configurable up to 300 pps
and the burst is configurable up to 15s long using the ip arp inspection
limit command.

•

Spanning tree: Spanning tree will diagnostically disable an interface when
it is unable to update the internal state of the interface for more than 90
seconds or when the internal message buffer for an interface overflows.

•

SFP+ transceivers: SFP+ transceivers are not compatible with SFP slots
(M3024F front panel ports). To avoid damage to SFP+ transceivers
mistakenly inserted into SFP ports, the SFP port is diagnostically disabled
when an SFP+ transceiver is detected.

•

ICMP storms: Ports on which ICMP storms are detected are diagnostically
disabled. The rate limit and burst sizes are configurable separately for IPv4
and IPv6.

A port that is diagnostically disabled may be returned to service using the no
shut command.

Captive Portal
The Captive Portal feature blocks clients from accessing the network until
user verification has been established. When a user attempts to connect to
the network through the switch, the user is presented with a customized Web
page that might contain username and password fields or the acceptable use
policy. You can require users to be authenticated by a local or remote RADIUS
database before access is granted.
For information about configuring the Captive Portal features, see "Captive
Portal" on page 543.
Switch Feature Overview

65

Dot1x Authentication (IEEE 802.1X)
Dot1x authentication enables the authentication of system users through a
local internal server or an external server. Only authenticated and approved
system users can transmit and receive frames over the port. Supplicants are
authenticated using the Extensible Authentication Protocol (EAP). PEAP,
EAP-TTL, EAP-TTLS, and EAP-TLS are supported for remote authentication
servers. Local (IAS) authentication supports EAP-MD5 only.
For information about configuring IEEE 802.1X settings, see "Configuring
Port and System Security" on page 503.

MAC-Based 802.1X Authentication
MAC-based authentication allows multiple supplicants connected to the
same port to each authenticate individually. For example, a system attached
to the port might be required to authenticate in order to gain access to the
network, while a VoIP phone might not need to authenticate in order to send
voice traffic through the port.
For information about configuring MAC-based 802.1X authentication, see
"Configuring Port and System Security" on page 503.

Dot1x Monitor Mode
Monitor mode can be enabled in conjunction with Dot1x authentication to
allow network access even when the user fails to authenticate. The switch logs
the results of the authentication process for diagnostic purposes. The main
purpose of this mode is to help troubleshoot the configuration of a Dot1x
authentication on the switch without affecting the network access to the
users of the switch.
For information about enabling the Dot1X Monitor mode, see "Configuring
Port and System Security" on page 503.

MAC-Based Port Security
The port security feature limits access on a port to users with specific MAC
addresses. These addresses are manually defined or learned on that port.
When a frame is seen on a locked port, and the frame source MAC address is
not tied to that port, the protection mechanism is invoked.
For information about configuring MAC-based port security, see "Configuring
Port and System Security" on page 503.
66

Switch Feature Overview

Access Control Lists (ACL)
Access Control Lists (ACLs) ensure that only authorized users have access to
specific resources while blocking off any unwarranted attempts to reach
network resources. ACLs are used to provide traffic flow control, restrict
contents of routing updates, decide which types of traffic are forwarded or
blocked, and above all provide security for the network. The switch supports
the following ACL types:
•

IPv4 ACLs

•

IPv6 ACLs

•

MAC ACLs

For all ACL types, you can apply the ACL rule when the packet enters or exits
the physical port, LAG, or VLAN interface.
ACLs can be used to implement policy-based routing (PBR) to implement
packet routing according to specific organizational policies.
For information about configuring ACLs and PBR, see "Configuring Access
Control Lists" on page 583.

Time-Based ACLs
With the Time-based ACL feature, you can define when an ACL is in effect
and the amount of time it is in effect.
For information about configuring time-based ACLs, see "Configuring Access
Control Lists" on page 583.

IP Source Guard (IPSG)
IP source guard (IPSG) is a security feature that filters IP packets based on
the source ID. The source ID may either be source IP address or a source IP
address source MAC address pair as found in the local DHCP snooping
database. IPSG depends on DHCP Snooping to associate IP address with
MAC addresses.
For information about configuring IPSG, see "Snooping and Inspecting
Traffic" on page 879.

Switch Feature Overview

67

DHCP Snooping
DHCP Snooping is a security feature that monitors DHCP messages between
a DHCP client and DHCP server. It filters harmful DHCP messages and
builds a bindings database of (MAC address, IP address, VLAN ID, port)
tuples that are specified as authorized. DHCP snooping can be enabled
globally and on specific VLANs. Ports within the VLAN can be configured to
be trusted or untrusted. DHCP servers must be reached through trusted ports.
For information about configuring DHCP Snooping, see "Snooping and
Inspecting Traffic" on page 879.

Dynamic ARP Inspection
Dynamic ARP Inspection (DAI) is a security feature that rejects invalid and
malicious ARP packets. The feature prevents a class of man-in-the-middle
attacks, where an unfriendly station intercepts traffic for other stations by
poisoning the ARP caches of its unsuspecting neighbors. The malicious
station sends ARP requests or responses mapping another station's IP address
to its own MAC address.
Dynamic ARP Inspection relies on DHCP Snooping.
For information about configuring DAI, see "Snooping and Inspecting Traffic"
on page 879.

Protected Ports (Private VLAN Edge)
Private VLAN Edge (PVE) ports are a Layer 2 security feature that provides
port-based security between ports that are members of the same VLAN. It is
an extension of the common VLAN. Traffic from protected ports is sent only
to the uplink ports and cannot be sent to other ports within the VLAN.
For information about configuring IPSG, see "Configuring Port-Based Traffic
Control" on page 787.

68

Switch Feature Overview

Green Technology Features
For information about configuring Green Technology features, see
"Configuring Port Characteristics" on page 477.

Energy Detect Mode
When the Energy Detect mode is enabled and the port link is down, the PHY
automatically goes down for short period of time and then wakes up
periodically to check link pulses. This mode reduces power consumption on
the port when no link partner is present.

Energy Efficient Ethernet
The switch supports the IEEE 802.3az Energy Efficient Ethernet (EEE)
Lower Power Idle Mode, which enables both the send and receive sides of the
link to disable some functionality for power savings when the link is lightly
loaded.
EEE and energy detect are supported on the N2000 and N3000 1G copper
ports. EEE is supported on the N4000 10G copper ports and energy detect is
supported on the N4000 10G and 40G copper ports.
EEE and energy detect are disabled by default on the N2000 and N3000
copper ports. Energy detect is enabled by default on the N4000 switches. EEE
is disabled by default on the N4000 10G copper ports.

Power Utilization Reporting
The switch displays the current power consumption of the power supply (or
power supplies). This information is available from the management
interface.

Switch Feature Overview

69

Power over Ethernet (PoE) Plus Features
NOTE: The Dell Networking N2024P/N2048P and N3024P/N3048P switches
support PoE Plus. The PoE Plus features do not apply to the other models in the
Dell Networking N2000/N3000/N4000 series.
For information about configuring PoE Plus features, see "Managing General
System Settings" on page 279."

Power Over Ethernet (PoE) Plus Configuration
The Dell Networking N2024P/N2048P and N3024P/N3048P switches support
PoE Plus configuration for power threshold, power priority, SNMP traps, and
PoE legacy device support. PoE can be administratively enabled or disabled
on a per-port basis. Power can also be limited on a per-port basis.

PoE Plus Support
The Dell Networking N2024P/N2048P and N3024P/N3048P switches
implement the PoE Plus specification (IEEE 802.1at), in addition to the
IEEE 802.3AF specification). This allows power to be supplied to Class 4 PD
devices that require power greater than 15.4 Watts. Each port is capable of
delivering up to 34.2W of power. Real-time power supply status is also
available on the switch as part of the PoE Plus implementation.

70

Switch Feature Overview

Switching Features
Flow Control Support (IEEE 802.3x)
Flow control enables lower speed switches to communicate with higher speed
switches by requesting that the higher speed switch refrain from sending
packets for a limited period of time. Transmissions are temporarily halted to
prevent buffer overflows.
For information about configuring flow control, see "Configuring Port-Based
Traffic Control" on page 787.

Head of Line Blocking Prevention
Head of Line (HOL) blocking prevention prevents traffic delays and frame
loss caused by traffic competing for the same egress port resources. HOL
blocking queues packets, and the packets at the head of the queue are
forwarded before packets at the end of the queue.

Alternate Store and Forward (ASF)
NOTE: This feature is available on the N4000 series switches only.
The Alternate Store and Forward (ASF) feature reduces latency for large
packets. When ASF is enabled, the memory management unit (MMU) can
forward a packet to the egress port before it has been entirely received on the
Cell Buffer Pool (CBP) memory.
AFS, which is also known as cut-through mode, is configurable through the
command-line interface. For information about how to configure the AFS
feature, see the CLI Reference Guide available at support.dell.com/manuals.

Jumbo Frames Support
Jumbo frames enable transporting data in fewer frames to ensure less
overhead, lower processing time, and fewer interrupts.
For information about configuring the switch MTU, see "Configuring Port
Characteristics" on page 477.

Switch Feature Overview

71

Auto-MDI/MDIX Support
Your switch supports auto-detection between crossed and straight-through
cables. Media-Dependent Interface (MDI) is the standard wiring for end
stations, and the standard wiring for hubs and switches is known as MediaDependent Interface with Crossover (MDIX). Auto-negotiation must be
enabled for MDIX to detect the wiring configuration.

VLAN-Aware MAC-based Switching
Packets arriving from an unknown source address are sent to the CPU and
added to the Hardware Table. Future packets addressed to or from this
address are more efficiently forwarded.

Back Pressure Support
On half-duplex links, a receiver may prevent buffer overflows by jamming the
link so that it is unavailable for additional traffic. On full-duplex links, a
receiver may send a PAUSE frame indicating that the transmitter should
cease transmission of frames for a specified period.
When flow control is enabled, the Dell Networking series switches will
observe received PAUSE frames or jamming signals, but will not issue them
when congested.

Auto Negotiation
Auto negotiation allows the switch to advertise modes of operation. The auto
negotiation function provides the means to exchange information between
two switches that share a point-to-point link segment, and to automatically
configure both switches to take maximum advantage of their transmission
capabilities.
Dell Networking series switches enhance auto negotiation by providing
configuration of port advertisement. Port advertisement allows the system
administrator to configure the port speeds that are advertised.
For information about configuring auto negotiation, see "Configuring Port
Characteristics" on page 477.

72

Switch Feature Overview

Broadcast Storm Control
When Layer 2 frames are forwarded, broadcast, unknown unicast, and
multicast frames are flooded to all ports on the relevant virtual local area
network (VLAN). The flooding occupies bandwidth, and loads all nodes
connected on all ports. Storm control limits the amount of broadcast,
unknown unicast, and multicast frames accepted and forwarded by the
switch.
For information about configuring Broadcast Storm Control settings, see
"Configuring Port-Based Traffic Control" on page 787.

Port Mirroring
Port mirroring monitors and mirrors network traffic by forwarding copies of
incoming and outgoing packets from multiple source ports to a monitoring
port. Source ports may be VLANs, physical interfaces, port-channels, or the
CPU port. The switch also supports flow-based mirroring, which allows you to
copy certain types of traffic to a single destination port. This provides
flexibility—instead of mirroring all ingress or egress traffic on a port the
switch can mirror a subset of that traffic. You can configure the switch to
mirror flows based on certain kinds of Layer 2, Layer 3, and Layer 4
information.
Dell Networking switches support RSPAN destinations where traffic can be
tunneled across the operational network. RSPAN does not support
configuration of the CPU port as a source.
For information about configuring port mirroring, see "Monitoring Switch
Traffic" on page 407.

Static and Dynamic MAC Address Tables
You can add static entries to the switch’s MAC address table and configure
the aging time for entries in the dynamic MAC address table. You can also
search for entries in the dynamic table based on several different criteria.
For information about viewing and managing the MAC address table, see
"Managing the MAC Address Table" on page 1015.

Switch Feature Overview

73

Link Layer Discovery Protocol (LLDP)
The IEEE 802.1AB defined standard, Link Layer Discovery Protocol (LLDP),
allows the switch to advertise major capabilities and physical descriptions.
This information can help you identify system topology and detect bad
configurations on the LAN.
For information about configuring LLDP, settings see "Discovering Network
Devices" on page 761.

Link Layer Discovery Protocol (LLDP) for Media Endpoint Devices
The Link Layer Discovery Protocol for Media Endpoint Devices (LLDPMED) provides an extension to the LLDP standard for network configuration
and policy, device location, Power over Ethernet management, and inventory
management.
For information about configuring LLDP-MED, settings see "Discovering
Network Devices" on page 761.

Connectivity Fault Management (IEEE 802.1ag)
NOTE: This feature is available on the N4000 series switches only.
The Connectivity Fault Management (CFM) feature, also known as Dot1ag,
supports Service Level Operations, Administration, and Management
(OAM). CFM is the OAM Protocol provision for end-to-end service layer
instance in carrier networks. The CFM feature provides mechanisms to help
you perform connectivity checks, fault detection, fault verification and
isolation, and fault notification per service in a network domain.
For information about configuring IEEE 802.1ag settings, see "Configuring
Connectivity Fault Management" on page 859.

Priority-based Flow Control (PFC)
NOTE: This feature is available on the N4000 switches only.
The Priority-based Flow Control feature allows the switch to pause or inhibit
transmission of individual priorities within a single physical link. By
configuring PFC to pause a congested priority (priorities) independently,
protocols that are highly loss sensitive can share the same link with traffic that
74

Switch Feature Overview

has different loss tolerances. Priorities are differentiated by the priority field
of the 802.1Q VLAN header. The N4000 switches support lossless transport of
frames on up to two priority classes.
NOTE: An interface that is configured for PFC is automatically disabled for 802.3x
flow control.
For information about configuring the PFC feature, see "Configuring Data
Center Bridging Features" on page 983.

Data Center Bridging Exchange (DBCx) Protocol
NOTE: This feature is available on the N4000 switches only.
The Data Center Bridging Exchange Protocol (DCBx) is used by DCB
devices to exchange configuration information with directly connected peers.
The protocol is also used to detect misconfiguration of the peer DCB devices
and, optionally, for configuration of peer DCB devices. For information about
configuring DCBx settings, see "Configuring Data Center Bridging Features"
on page 983. DCBx is a link-local protocol and operates only on individual
links.

Enhanced Transmission Selection
NOTE: This feature is available on the N4000 switches only.
Enhanced Transmission Selection (ETS) allows the switch to allocate
bandwidth to traffic classes and share unused bandwidth with lower-priority
traffic classes while coexisting with strict-priority traffic classes. ETS is
supported on the Dell Networking N4000 series switches and can be
configured manually or automatically using the auto configuration feature.
For more information about ETS, see "Enhanced Transmission Selection" on
page 999.

Switch Feature Overview

75

Cisco Protocol Filtering
The Cisco Protocol Filtering feature (also known as Link Local Protocol
Filtering) filters Cisco protocols that should not normally be relayed by a
bridge. The group addresses of these Cisco protocols do not fall within the
IEEE defined range of the 802.1D MAC Bridge Filtered MAC Group
Addresses (01-80-C2-00-00-00 to 01-80-C2-00-00-0F).
For information about configuring LLPF, settings see "Configuring PortBased Traffic Control" on page 787.

DHCP Layer 2 Relay
This feature permits Layer 3 Relay agent functionality in Layer 2 switched
networks. The switch supports L2 DHCP relay configuration on individual
ports, link aggregation groups (LAGs) and VLANs.
For information about configuring L2 DHCP Relay settings see "Configuring
L2 and L3 Relay Features" on page 1087.

76

Switch Feature Overview

Virtual Local Area Network Supported Features
For information about configuring VLAN features see "Configuring VLANs"
on page 645.

VLAN Support
VLANs are collections of switching ports that comprise a single broadcast
domain. Packets are classified as belonging to a VLAN based on either the
VLAN tag or a combination of the ingress port and packet contents. Packets
sharing common attributes can be groups in the same VLAN. The Dell
Networking series switches are in full compliance with IEEE 802.1Q VLAN
tagging.

Port-Based VLANs
Port-based VLANs classify incoming packets to VLANs based on their ingress
port. When a port uses 802.1X port authentication, packets can be assigned
to a VLAN based on the result of the 802.1X authentication a client uses
when it accesses the switch. This feature is useful for assigning traffic to
Guest VLANs or Voice VLANs.

IP Subnet-based VLAN
This feature allows incoming untagged packets to be assigned to a VLAN and
traffic class based on the source IP address of the packet.

MAC-based VLAN
This feature allows incoming untagged packets to be assigned to a VLAN and
traffic class based on the source MAC address of the packet.

IEEE 802.1v Protocol-Based VLANs
VLAN classification rules are defined on data-link layer (Layer 2) protocol
identification. Protocol-based VLANs are used for isolating Layer 2 traffic for
differing Layer 3 protocols.

Switch Feature Overview

77

GARP and GVRP Support
The switch supports the Generic Attribute Registration Protocol (GARP).
GARP VLAN Registration Protocol (GVRP) relies on the services provided by
GARP to provide IEEE 802.1Q-compliant VLAN pruning and dynamic
VLAN creation on 802.1Q trunk ports. When GVRP is enabled, the switch
registers and propagates VLAN membership on all ports that are part of the
active spanning tree protocol topology.
For information about configuring GARP timers see "Configuring L2
Multicast Features" on page 803.

Voice VLAN
The Voice VLAN feature enables switch ports to carry voice traffic with
defined priority. The priority level enables the separation of voice and data
traffic coming onto the port. Voice VLAN is the preferred solution for
enterprises wishing to deploy voice services in their network.

Guest VLAN
The Guest VLAN feature allows a switch to provide a distinguished service to
unauthenticated users. This feature provides a mechanism to allow visitors
and contractors to have network access to reach external network with no
ability to browse information on the internal LAN.
For information about configuring the Guest VLAN see "Configuring Port
and System Security" on page 503.

Double VLANs
The Double VLAN feature (IEEE 802.1QinQ) allows the use of a second tag
on network traffic. The additional tag helps differentiate between customers
in the Metropolitan Area Networks (MAN) while preserving individual
customer’s VLAN identification when they enter their own 802.1Q domain.

78

Switch Feature Overview

Spanning Tree Protocol Features
For information about configuring Spanning Tree Protocol features, see
"Configuring the Spanning Tree Protocol" on page 715.

Spanning Tree Protocol (STP)
Spanning Tree Protocol (IEEE 802.1D) is a standard requirement of Layer 2
switches that allows bridges to automatically prevent and resolve L2
forwarding loops.

Spanning Tree Port Settings
The STP feature supports a variety of per-port settings including path cost,
priority settings, Port Fast mode, STP Root Guard, Loop Guard, TCN Guard,
and Auto Edge. These settings are also configurable per-LAG.

Rapid Spanning Tree
Rapid Spanning Tree Protocol (RSTP) detects and uses network topologies to
enable faster spanning tree convergence after a topology change, without
creating forwarding loops. The port settings supported by STP are also
supported by RSTP.

Multiple Spanning Tree
Multiple Spanning Tree (MSTP) operation maps VLANs to spanning tree
instances. Packets assigned to various VLANs are transmitted along different
paths within MSTP Regions (MST Regions). Regions are one or more
interconnected MSTP bridges with identical MSTP settings. The MSTP
standard lets administrators assign VLAN traffic to unique paths.
The switch supports IEEE 802.1Q-2005, which is a version of corrects
problems associated with the previous version, provides for faster transitionto-forwarding, and incorporates new features for a port (restricted role and
restricted TCN).

Switch Feature Overview

79

Bridge Protocol Data Unit (BPDU) Guard
Spanning Tree BPDU Guard is used to disable the port in case a new device
tries to enter the already existing topology of STP. Thus devices, which were
originally not a part of STP, are not allowed to influence the STP topology.

BPDU Filtering
When spanning tree is disabled on a port, the BPDU Filtering feature allows
BPDU packets received on that port to be dropped. Additionally, the BPDU
Filtering feature prevents a port in Port Fast mode from sending and receiving
BPDUs. A port in Port Fast mode is automatically placed in the forwarding
state when the link is up to increase convergence time.

RSTP-PV and STP-PV
Dell Networking switches support both Rapid Spanning Tree Per VLAN
(RSTP-PV) and Spanning Tree Per VLAN (STP-PV). RSTP-PV is the IEEE
802.1w (RSTP) standard implemented per VLAN. A single instance of rapid
spanning tree (RSTP) runs on each configured VLAN. Each RSTP instance
on a VLAN has a root switch. STP-PV is the IEEE 802.1s (STP) standard
implemented per VLAN.

80

Switch Feature Overview

Link Aggregation Features
For information about configuring link aggregation (port-channel) features,
see "Configuring Link Aggregation" on page 913.

Link Aggregation
Up to eight ports can combine to form a single Link Aggregation Group
(LAG). This enables fault tolerance protection from physical link disruption,
higher bandwidth connections and improved bandwidth granularity.
Per IEEE 802.1AX, only links with the same operational characteristics, such
as speed and duplex setting, may be aggregated. Dell Networking switches
aggregate links only if they have the same operational speed and duplex
setting, as opposed to the configured speed and duplex setting. This allows
operators to aggregate links that use auto negotiation to set values for speed
and duplex or to aggregate ports with SFP+ technology operating at a lower
speed, e.g., 1G. Dissimilar ports will not become active in the LAG if their
operational settings do not match those of the first member of the LAG.

Link Aggregate Control Protocol (LACP)
Link Aggregate Control Protocol (LACP) uses peer exchanges across links to
determine, on an ongoing basis, the aggregation capability of various links,
and continuously provides the maximum level of aggregation capability
achievable between a given pair of systems. LACP automatically determines,
configures, binds, and monitors the binding of ports to aggregators within the
system.

Multi-Switch LAG (MLAG)
Dell Networking switches support the MLAG feature to extends the LAG
bandwidth advantage across multiple Dell Networking switches connected to
a LAG partner device. The LAG partner device is oblivious to the fact that it
is connected over a LAG to two peer Dell Networking switches; instead, the
two switches appear as a single switch to the partner. When using MLAG, all
links can carry data traffic across a physically diverse topology and, in the case
of a link or switch failure, traffic can continue to flow with minimal
disruption.

Switch Feature Overview

81

Routing Features
Address Resolution Protocol (ARP) Table Management
You can create static ARP entries and manage many settings for the dynamic
ARP table, such as age time for entries, retries, and cache size.
For information about managing the ARP table, see "Configuring IP Routing"
on page 1063.

VLAN Routing
Dell Networking series switches support VLAN routing. You can also
configure the software to allow traffic on a VLAN to be treated as if the VLAN
were a router port.
For information about configuring VLAN routing interfaces, see "Configuring
Routing Interfaces" on page 1021.

IP Configuration
The switch IP configuration settings to allow you to configure network
information for VLAN routing interfaces such as IP address and subnet mask,
and ICMP redirects. Global IP configuration settings for the switch allow you
to enable or disable the generation of several types of ICMP messages and
enable or disable the routing mode.
For information about managing global IP settings, see "Configuring IP
Routing" on page 1063.

Open Shortest Path First (OSPF)
NOTE: This feature is not available on N2000 switches.
Open Shortest Path First (OSPF) is a dynamic routing protocol commonly
used within medium-to-large enterprise networks. OSPF is an interior
gateway protocol (IGP) that operates within a single autonomous system.
For information about configuring OSPF, see "Configuring OSPF and
OSPFv3" on page 1111.

82

Switch Feature Overview

BOOTP/DHCP Relay Agent
The switch BootP/DHCP Relay Agent feature relays BootP and DHCP
messages between DHCP clients and DHCP servers that are located in
different IP subnets.
For information about configuring the BootP/DHCP Relay agent, see
"Configuring L2 and L3 Relay Features" on page 1087.

IP Helper and UDP Relay
The IP Helper and UDP Relay features provide the ability to relay various
protocols to servers on a different subnet.
For information about configuring the IP helper and UDP relay features, see
"Configuring L2 and L3 Relay Features" on page 1087.

Routing Information Protocol
Routing Information Protocol (RIP), like OSPF, is an IGP used within an
autonomous Internet system. RIP is an IGP that is designed to work with
moderate-size networks.
For information about configuring RIP, see "Configuring RIP" on page 1201.

Router Discovery
For each interface, you can configure the Router Discovery Protocol (RDP) to
transmit router advertisements. These advertisements inform hosts on the
local network about the presence of the router.
For information about configuring router discovery, see "Configuring IP
Routing" on page 1063.

Routing Table
The routing table displays information about the routes that have been
dynamically learned. You can configure static and default routes and route
preferences. A separate table shows the routes that have been manually
configured.
For information about viewing the routing table, see "Configuring IP
Routing" on page 1063.

Switch Feature Overview

83

Virtual Router Redundancy Protocol (VRRP)
NOTE: This feature is not available on N2000 switches.
VRRP provides hosts with redundant routers in the network topology without
any need for the hosts to reconfigure or know that there are multiple routers.
If the primary (master) router fails, a secondary router assumes control and
continues to use the virtual router IP (VRIP) address.
VRRP Route Interface Tracking extends the capability of VRRP to allow
tracking of specific route/interface IP states within the router that can alter
the priority level of a virtual router for a VRRP group.
For information about configuring VRRP settings, see "Configuring VRRP"
on page 1217.

Tunnel and Loopback Interfaces
NOTE: This feature is not available on N2000 switches.
Dell Networking series switches support the creation, deletion, and
management of tunnel and loopback interfaces. Tunnel interfaces facilitate
the transition of IPv4 networks to IPv6 networks. A loopback interface is
always expected to be up, so you can configure a stable IP address that other
network devices use to contact or identify the switch.
For information about configuring tunnel and loopback interfaces, see
"Configuring Routing Interfaces" on page 1021.

84

Switch Feature Overview

IPv6 Routing Features
NOTE: This feature is not available on N2000 switches.

IPv6 Configuration
The switch supports IPv6, the next generation of the Internet Protocol. You
can globally enable IPv6 on the switch and configure settings such as the IPv6
hop limit and ICMPv6 rate limit error interval. You can also control whether
IPv6 is enabled on a specific interface. The switch supports the configuration
of many per-interface IPv6 settings including the IPv6 prefix and prefix
length.
For information about configuring general IPv6 routing settings, see
"Configuring IPv6 Routing" on page 1241.

IPv6 Routes
Because IPv4 and IPv6 can coexist on a network, the router on such a network
needs to forward both traffic types. Given this coexistence, each switch
maintains a separate routing table for IPv6 routes. The switch can forward
IPv4 and IPv6 traffic over the same set of interfaces.
For information about configuring IPv6 routes, see "Configuring IPv6
Routing" on page 1241.

OSPFv3
OSPFv3 provides a routing protocol for IPv6 networking. OSPFv3 is a new
routing component based on the OSPF version 2 component. In dual stack
IPv6, you can configure and use both OSPF and OSPFv3 components.
For information about configuring OSPFv3, see "Configuring OSPF and
OSPFv3" on page 1111.

DHCPv6
DHCPv6 incorporates the notion of the “stateless” server, where DHCPv6 is
not used for IP address assignment to a client, rather it only provides other
networking information such as DNS, Network Time Protocol (NTP), and/or
Session Initiation Protocol (SIP) information.

Switch Feature Overview

85

For information about configuring DHCPv6 settings, see "Configuring
DHCPv6 Server and Relay Settings" on page 1265.

Quality of Service (QoS) Features
NOTE: Some features that can affect QoS, such as ACLs and Voice VLAN, are
described in other sections within this chapter.

Differentiated Services (DiffServ)
The QoS Differentiated Services (DiffServ) feature allows traffic to be
classified into streams and given certain QoS treatment in accordance with
defined per-hop behaviors. Dell Networking series switches support both IPv4
and IPv6 packet classification.
For information about configuring DiffServ, see "Configuring Differentiated
Services" on page 1285.

Class Of Service (CoS)
The Class Of Service (CoS) queueing feature lets you directly configure
certain aspects of switch queuing. This provides the desired QoS behavior for
different types of network traffic when the complexities of DiffServ are not
required. CoS queue characteristics, such as minimum guaranteed
bandwidth and transmission rate shaping, are configurable at the queue (or
port) level.
For information about configuring CoS, see "Configuring Class-of-Service" on
page 1313.

Auto Voice over IP (VoIP)
This feature provides ease of use for the user in setting up VoIP for IP phones
on a switch. This is accomplished by enabling a VoIP profile that a user can
select on a per port basis.
For information about configuring Auto VoIP, see "Configuring Auto VoIP" on
page 1331.

86

Switch Feature Overview

Internet Small Computer System Interface (iSCSI) Optimization
The iSCSI Optimization feature helps network administrators track iSCSI
traffic between iSCSI initiator and target systems. This is accomplished by
monitoring, or snooping traffic to detect packets used by iSCSI stations in
establishing iSCSI sessions and connections. Data from these exchanges may
optionally be used to create classification rules to assign the traffic between
the stations to a configured traffic class. This affects how the packets in the
flow are queued and scheduled for egress on the destination port.
For information about configuring iSCSI settings, see "Configuring iSCSI
Optimization" on page 459.

Layer 2 Multicast Features
For information about configuring L2 multicast features, see "Configuring L2
Multicast Features" on page 803.

MAC Multicast Support
Multicast service is a limited broadcast service that allows one-to-many and
many-to-many connections. In Layer 2 multicast services, a single frame
addressed to a specific multicast address is received, and copies of the frame
to be transmitted on each relevant port are created.

IGMP Snooping
Internet Group Management Protocol (IGMP) Snooping is a feature that
allows a switch to forward multicast traffic intelligently on the switch.
Multicast traffic is traffic that is destined to a host group. Host groups are
identified by the destination MAC address, i.e. the range 01:00:5e:00:00:00 to
01:00:5e:7f:ff:ff:ff for IPv4 multicast traffic or 33:33:xx:xx:xx:xx for IPv6
multicast traffic. Based on the IGMP query and report messages, the switch
forwards traffic only to the ports that request the multicast traffic. This
prevents the switch from broadcasting the traffic to all ports and possibly
affecting network performance.

Switch Feature Overview

87

IGMP Snooping Querier
When Protocol Independent Multicast (PIM) and IGMP are enabled in a
network with IP multicast routing, the IP multicast router acts as the IGMP
querier. However, if it is desirable to keep the multicast network Layer 2
switched only, the IGMP Snooping Querier can perform the query functions
of a Layer 3 multicast router.

MLD Snooping
In IPv4, Layer 2 switches can use IGMP Snooping to limit the flooding of
multicast traffic by dynamically configuring Layer 2 interfaces so that
multicast traffic is forwarded to only those interfaces associated with IP
multicast address.
In IPv6, MLD snooping performs a similar function. With MLD snooping,
IPv6 multicast data is selectively forwarded to a list of ports intended to
receive the data (instead of being flooded to all of the ports in a VLAN). This
list is constructed by snooping IPv6 multicast control packets.

Multicast VLAN Registration
The Multicast VLAN Registration (MVR) protocol, like IGMP Snooping,
allows a Layer 2 switch to listen to IGMP frames and forward the multicast
traffic only to the receivers that request it. Unlike IGMP Snooping, MVR
allows the switch to listen across different VLANs. MVR uses a dedicated
VLAN, which is called the multicast VLAN, to forward multicast traffic over
the Layer 2 network to the various VLANs that have multicast receivers as
members.

88

Switch Feature Overview

Layer 3 Multicast Features
For information about configuring L3 multicast features, see "Managing IPv4
and IPv6 Multicast" on page 1337.
NOTE: This feature is not available on N2000 switches.

Distance Vector Multicast Routing Protocol
Distance Vector Multicast Routing Protocol (DVMRP) exchanges probe
packets with all DVMRP-enabled routers, establishing two way neighboring
relationships and building a neighbor table. It exchanges report packets and
creates a unicast topology table, which is used to build the multicast routing
table. This multicast route table is then used to route the multicast packets.

Internet Group Management Protocol
The Internet Group Management Protocol (IGMP) is used by IPv4 systems
(hosts and routers) to report their IP multicast group memberships to any
neighboring multicast routers. Dell Networking series switches perform the
“multicast router part” of the IGMP protocol, which means it collects the
membership information needed by the active multicast router.

IGMP Proxy
The IGMP Proxy feature allows the switch to act as a proxy for hosts by
sending IGMP host messages on behalf of the hosts that the switch
discovered through standard IGMP router interfaces.

Protocol Independent Multicast—Dense Mode
Protocol Independent Multicast (PIM) is a standard multicast routing
protocol that provides scalable inter-domain multicast routing across the
Internet, independent of the mechanisms provided by any particular unicast
routing protocol. The Protocol Independent Multicast-Dense Mode (PIMDM) protocol uses an existing Unicast routing table and a Join/Prune/Graft
mechanism to build a tree. PIM-DM creates source-based shortest-path
distribution trees, making use of reverse path forwarding (RPF).

Switch Feature Overview

89

Protocol Independent Multicast—Sparse Mode
Protocol Independent Multicast-Sparse Mode (PIM-SM) is used to efficiently
route multicast traffic to multicast groups that may span wide area networks,
and where bandwidth is a constraint. PIM-SM uses shared trees by default
and implements source-based trees for efficiency. This data threshold rate is
used to toggle between trees.

Protocol Independent Multicast—Source Specific Multicast
Protocol Independent Multicast—Source Specific Multicast (PIM-SSM) is a
subset of PIM-SM and is used for one-to-many multicast routing
applications, such as audio or video broadcasts. PIM-SSM does not use shared
trees.

Protocol Independent Multicast IPv6 Support
PIM-DM and PIM-SM support IPv6 routes.

MLD/MLDv2 (RFC2710/RFC3810)
MLD is used by IPv6 systems (listeners and routers) to report their IP
multicast addresses memberships to any neighboring multicast routers. The
implementation of MLD v2 is backward compatible with MLD v1.
MLD protocol enables the IPv6 router to discover the presence of multicast
listeners, the nodes that want to receive the multicast data packets, on its
directly attached interfaces. The protocol specifically discovers which
multicast addresses are of interest to its neighboring nodes and provides this
information to the multicast routing protocol that make the decision on the
flow of the multicast data packets.

90

Switch Feature Overview

3

Hardware Overview

This section provides an overview of the switch hardware. It is organized by
product type:
•

Dell Networking N2000 Series Switch Hardware

•

Dell Networking N3000 Series Switch Hardware

•

Dell Networking N4000 Series Switch Hardware

•

Switch MAC Addresses

Dell Networking N2000 Series Switch Hardware
This section contains information about device characteristics and modular
hardware configurations for the N2000 series switches.

N2000 Series Front Panel
Then N2000 series front panel includes the following features:
•

Switch Ports

•

Console Port

•

USB Port

•

Reset Button

•

SFP+ Ports

•

Port and System LEDs

•

Stack Master LED and Stack Number Display

The following images show the front panels of the switch models in the
N2000 series.

Hardware Overview

91

Figure 3-1. N2048 Switch with 48 10/100/1000BASE-T Ports (Front Panel)
Console Port

48 10/100/1000BASE-T Ports

USB Port

SFP+ Ports

In addition to the switch ports, the front panel of each model in the N2000
series includes the following ports:
•

Console port

•

USB port

Figure 3-2. N2024 Close-up

The N2024 front panel, shown in Figure 3-2, has status LEDs for overtemperature alarm, internal power, and status on the top row. The bottom
row of status LEDs displays stack master, redundant power supply (RPS)
status and fan alarm status.

92

Hardware Overview

Figure 3-3. N2024P Close-up

The N2024P front panel, shown in Figure 3-3, has status LEDs for overtemperature alarm, internal power and status on the top row. The bottom row
of status LEDs displays stack master, modular power supply (MPS) status and
fan alarm status.
Switch Ports

The N2024/N2024P front panel provides 24 Gigabit Ethernet
(10/100/1000BASE-T) RJ-45 ports that support auto-negotiation for speed,
flow control, and duplex. The N2024/N2024P models support two SFP+ 10G
ports. Dell-qualified SFP+ transceivers are sold separately.
The N2048/N2048P front panel provides 48 Gigabit Ethernet (10BASE-T,
100BASE-TX, 1000BASE-T) RJ-45 ports that support auto-negotiation for
speed, flow control, and duplex. The N2048/N2048P support two SFP+ 10G
ports. Dell-qualified SFP+ transceivers are sold separately.
The front-panel switch ports have the following characteristics:
•

The switch automatically detects the difference between crossed and
straight-through cables on RJ-45 ports and automatically chooses the MDI
or MDIX configuration to match the other end.

•

SFP+ ports support Dell-qualified transceivers. The default behavior is to
log a message and generate an SNMP trap on insertion or removal of an
optic that is not qualified by Dell. The message and trap can be suppressed
by using the service unsupported-transceiver command.
Hardware Overview

93

•

RJ-45 ports support full-duplex mode 10/100/1000 Mbps speeds on
standard Category 5 UTP cable.

•

SFP+ ports support SFP+ transceivers and SFP+ copper twin-ax
technology operating at 10G or 1G plus SFP transceivers operating at 1G.

•

The N2024P/N2048P front panel ports support PoE (15.4W) and PoE+
(34.2W).

Console Port

The console port provides serial communication capabilities, which allows
communication using RS-232 protocol. The serial port provides a direct
connection to the switch and allows access to the CLI from a console
terminal connected to the port through the provided serial cable (with RJ45
YOST to female DB-9 connectors).
The console port is separately configurable and can be run as an asynchronous
link from 1200 baud to 115,200 baud.
The Dell CLI only supports changing the speed. The defaults are 9600 baud
rate, 8 data bits, No Parity, 1 Stop Bit, No Flow Control.
USB Port

The Type-A, female USB port supports a USB 2.0-compliant flash memory
drive. The Dell Networking switch can read or write to a flash drive with a
single partition formatted as FAT-32. You can use a USB flash drive to copy
switch configuration files and images between the USB flash drive and the
switch. You can also use the USB flash drive to move and copy configuration
files and images from one switch to other switches in the network. The
system does not support the deletion of files on USB flash drives.
The USB port does not support any other type of USB device.
Reset Button

The reset button is accessed through the pinhole and allows you to perform a
hard reset on the switch. To use the reset button, insert an unbent paper clip
or similar tool into the pinhole. When the switch completes the boot process
after the reset, it resumes operation with the most recently saved
configuration. Any changes made to the running configuration that were not
saved to the startup configuration prior to the reset are lost.

94

Hardware Overview

Port and System LEDs

The front panel contains light emitting diodes (LEDs) that indicate the
status of port links, power supplies, fans, stacking, and the overall system
status. See "N2000 LED Definitions" on page 97 for more information.
Stack Master LED and Stack Number Display

When a switch within a stack is the master unit, the stack master LED, which
is labeled M, is solid green. If the M LED is off, the stack member is not the
master unit. The Stack No. panel displays the unit number for the stack
member. If a switch is not part of a stack (in other words, it is a stack of one
switch), the M LED is illuminated, and the unit number is displayed.

N2000 Series Back Panel
The following images show the back panels of the N2000 switches.
Figure 3-4. N2000 Back Panel

Fan Vents

AC Power Receptacle

Figure 3-5. N2024P/N2048P Back Panel

The term mini-SAS refers to the stacking port cable connections shown in
Figure 3-6. See "Managing a Switch Stack" on page 171 for information on
using the mini-SAS ports to connect switches.

Hardware Overview

95

Figure 3-6. N2048 Mini-SAS Stacking Ports and Fans

Mini-SAS stacking ports

Power Supplies

N2024 and N2048

N2024 and N2048 series switches have an internal 100-watt power supply.
The additional redundant power supply (Dell Networking RPS720) provides
180 watts of power and gives full redundancy for the switch.
N2024P and N2048P

N2024P and N2048P switches have an internal 1000-watt power supply
feeding up to 24 PoE devices at full PoE+ power (850W). An additional
external power supply (MPS1000) provides 1000 watts and gives full power
coverage for all 48 PoE devices (1800W).
NOTE: PoE power is dynamically allocated. Not all ports will require the full PoE+

power.

CAUTION: Remove the power cable from the power supplies prior to removing
the power supply module itself. Power must not be connected prior to insertion in
the chassis.
Ventilation System

Two fans cool the N2000 switches.
Information Tag

The back panel includes a slide-out label panel that contains system
information, such as the Service Tag, MAC address, and so on.

96

Hardware Overview

N2000 LED Definitions
This section describes the LEDs on the front and back panels of the switch.
Port LEDs

Each port on an N2000 switch includes two LEDs. One LED is on the left
side of the port, and the second LED is on the right side of the port. This
section describes the LEDs on the switch ports.
100/1000/10000Base-T Port LEDs

Each 100/1000/10000Base-T port has two LEDs. Figure 3-20 illustrates the
100/1000/10000Base-T port LEDs.
Figure 3-7. 100/1000/10000Base-T Port LEDs

Link/SPD

Activity

Hardware Overview

97

Table 3-16 shows the 100/1000/10000Base-T port LED definitions.
Table 3-1.

100/1000/10000Base-T Port Definitions

LED

Color

Link/SPD LED Off

Definition
There is no link.

Solid yellow

The port is operating at 10/100 Mbps.

Solid green

The port is operating at 1000 Mbps.

Activity LED
(on non-PoE
switches)

Off

There is no current transmit/receive activity.

Blinking green

The port is actively transmitting/receiving.

Activity/PoE
LED (on PoE
switches)

Off

There is no current transmit/receive activity
and PoE power is off.

Blinking green

The port is actively transmitting/receiving and
PoE power is off.

Blinking yellow

The port is actively transmitting/receiving and
PoE power is on.

Solid yellow

There is no current transmit/receive activity
and PoE power is on.

Stacking Port LEDs
Table 3-2.

Stacking Port LED Definitions

LED

Color

Definition

Link LED

Off

There is no link.

Solid green

The port is actively transmitting/receiving.

Off

There is no current transmit/receive activity.

Blinking green

The port is actively transmitting/receiving.

Activity LED

98

Hardware Overview

Table 3-3.

Console Port LED Definitions

LED

Color

Definition

Link/SPD LED Off

There is no link.

Solid green

A link is present.

System LEDs

The system LEDs, located on the back panel, provide information about the
power supplies, thermal conditions, and diagnostics.
Table 3-21 shows the System LED definitions for the N2000 series switches.
Table 3-4.

System LED Definitions

LED

Color

Definition

Status

Solid green

Normal operation.

Blinking green

The switch is booting

Solid red

A critical system error has occurred.

Blinking red

A noncritical system error occurred (fan or power
supply failure).

Off

There is no power or the switch has experienced a
power failure.

Solid green

Power to the switch is on.

Blinking green

The switch locator function is enabled.

Power

RPS (on Off
non-PoE
Solid green
switches)
Solid red

There is no redundant power supply (RPS).

EPS (on Off
PoE
Solid green
switches)
Solid red

There is no external power supply (EPS).

Fan

Power to the RPS is on.
An RPS is detected but it is not receiving power.
Power to the EPS is on.
An EPS is detected but it is not receiving power.

Solid green

The fan is powered and is operating at the expected
RPM.

Solid red

A fan failure has occurred.

Hardware Overview

99

Table 3-4.

System LED Definitions (Continued)

LED

Color

Definition

Stack
master

Off

The switch is in stand-alone mode.

Solid green

The switch is master for the stack.

Temp

Solid green

The switch is operating below the threshold
temperature.

Solid red

The switch temperature exceeds the threshold of 75°C.

Stack No. –

Switch ID within the stack.

Power Consumption for N2000 Series PoE Switches
Table 3-5 shows power consumption data for the PoE-enabled switches.
Table 3-5.

Power Consumption

Model

Input
Voltage

Power Supply
Configuration

Max Steady
Current
Consumption (A)

Max Steady
Power (W)

N2024P

100V

Main PSU+EPS PSU

8.9

890.0

110V

Main PSU+EPS PSU

8.3

913.0

120V

Main PSU+EPS PSU

7.6

912.0

220V

Main PSU+EPS PSU

4.0

880.0

240V

Main PSU+EPS PSU

3.6

873.6

100V

Main PSU+EPS PSU

17.8

1780.0

110V

Main PSU+EPS PSU

15.8

1740.2

120V

Main PSU+EPS PSU

14.5

1740.0

220V

Main PSU+EPS PSU

7.7

1687.4

240V

Main PSU+EPS PSU

7.1

1704.0

N2048P

The PoE power budget for each interface is controlled by the switch firmware.
The administrator can limit the power supplied on a port or prioritize power
to some ports over others. Table 3-6 shows power budget data.

100

Hardware Overview

Table 3-6.

N2000 Series PoE Power Budget Limit
One PSU Support

Two PSUs Support

Model
Name

System Power
Max. PSU
POE+ Power
Max. Dissipation Output Ability Turn-on Limitation

Max. PSUs
POE+ Power
Output Ability Turn-on Limitation

N2024P

90W

2000W

1000W

Power budget is
850W:
The total POE
supplied power
must not exceed
850W.

N2048P

110W

1000W

Power budget is
850W:
The total POE
supplied power
must not exceed
850W.

Power budget is
1700W:
All PoE+ ports can
supply maximum
power.

2000W

Power budget is
1700W:
All PoE+ ports can
supply maximum
power.

Hardware Overview

101

Dell Networking N3000 Series Switch Hardware
This section contains information about device characteristics and modular
hardware configurations for the N3000 series switches.

N3000 Series Front Panel
The N2000 series front panel includes the following features:
•

Switch Ports

•

Console Port

•

Out-of-Band Management Port

•

USB Port

•

SFP+ Ports

•

Reset Button

•

Port and System LEDs

•

Stack Master LED and Stack Number Display

The following images show the front panels of the switch models in the
N3000 series.
Figure 3-8.

N3024F with 24 10/100/1000BASE-T Ports (Front Panel)

10/100/1000BASE-T Auto-sensing
Full Duplex RJ-45 Ports

Combo
Ports

SFP+
Ports

The N3000 series switch includes two combo ports. The combo ports are SFP
on the N3000 series and 1000BaseT on the N3024F switch.

102

Hardware Overview

Figure 3-9. N3048 with 48 10/100/1000BASE-T Ports (Front Panel)

10/100/1000BASE-T Auto-sensing
Full Duplex RJ-45 Ports

Combo
Ports

SFP+
Ports

The additional ports are on the right side of the front panel, as shown in
Figure 3-9 and Figure 3-10 on page 103.
Figure 3-10.

Additional N3000 Series Ports

Console Port

Out-of-Band Management Port

USB Port

Reset Button

Combo Ports

SFP+ Ports

The N3000 front panel above also contains a reset button (pinhole) and
several status LEDs. See Figure 3-10.

Hardware Overview

103

The N3000 front panel also displays status LEDs for over-temperature alarm,
internal power supply 1 and switch status on the top row. The bottom row of
status LEDs displays stack master, internal power supply 2 and fan alarm.
Switch Ports

The N3024/N3024P front panel provides 24 Gigabit Ethernet
(10/100/1000BASE-T) RJ-45 ports that support auto-negotiation for speed,
flow control, and duplex. The N3024P models support two SFP+ 10G ports.
Dell-qualified SFP+ transceivers are sold separately.
The N3024F front panel provides 24 Gigabit Ethernet 100BASEFX/1000BASE-X SFP ports plus 2 1000BASE-T combo ports. Dell-qualified
SFP transceivers are sold separately.
The N3048/N3048P front panel provides 48 Gigabit Ethernet (10BASE-T,
100BASE-TX, 1000BASE-T) RJ-45 ports that support auto-negotiation for
speed, flow control, and duplex. The N3048/N3048P support two SFP+ 10G
ports. Dell-qualified SFP+ transceivers are sold separately.
The front-panel switch ports have the following characteristics:

104

•

The switch automatically detects the difference between crossed and
straight-through cables on RJ-45 ports and automatically chooses the MDI
or MDIX configuration to match the other end.

•

SFP+ ports support Dell-qualified transceivers. The default behavior is to
log a message and generate an SNMP trap on insertion or removal of an
optic that is not qualified by Dell. The message and trap can be suppressed
by using the service unsupported-transceiver command.

•

RJ-45 ports support full-duplex mode 10/100/1000 Mbps speeds on
standard Category 5 UTP cable.

•

SFP+ ports support SFP+ transceivers and SFP+ copper twin-ax
technology operating at 10G/1G plus SFP transceivers operating at 1G.

•

The N3024P/N3048P front panel ports support PoE (15.4W) and PoE+
(34.2W).

Hardware Overview

Console Port

The console port provides serial communication capabilities, which allows
communication using RS-232 protocol. The serial port provides a direct
connection to the switch and allows access to the CLI from a console
terminal connected to the port through the provided serial cable (with RJ45
YOST to female DB-9 connectors).
The console port is separately configurable and can be run as an asynchronous
link from 1200 baud to 115,200 baud.
The Dell CLI only supports changing the speed.
The defaults are 9600 baud rate, 8 data bits, No Parity, 1 Stop Bit, No Flow
Control.
Out-of-Band Management Port

The Out-of-Band (OOB) management port is a 10/100/1000BASE-T
Ethernet port dedicated to remote switch management. Traffic on this port is
segregated from operational network traffic on the switch ports and cannot be
switched or routed to or from the operational network.
USB Port

The Type-A, female USB port supports a USB 2.0-compliant flash memory
drive. The Dell Networking switch can read or write to a flash drive with a
single partition formatted as FAT-32. You can use a USB flash drive to copy
switch configuration files and images between the USB flash drive and the
switch. You can also use the USB flash drive to move and copy configuration
files and images from one switch to other switches in the network. The
system does not support the deletion of files on attached USB flash drives.
The USB port does not support any other type of USB device.
Reset Button

The reset button is accessed through the pinhole and allows you to perform a
hard reset on the switch. To use the reset button, insert an unbent paper clip
or similar tool into the pinhole. When the switch completes the boot process
after the reset, it resumes operation with the most recently saved
configuration. Any changes made to the running configuration that were not
saved to the startup configuration prior to the reset are lost.

Hardware Overview

105

Port and System LEDs

The front panel contains light emitting diodes (LEDs) that indicate the
status of port links, power supplies, fans, stacking, and the overall system
status.
For information about the status that the LEDs indicate, see the User’s

Configuration Guide.

Stack Master LED and Stack Number Display

When a switch within a stack is the master unit, the stack master LED, which
is labeled M, is solid green. If the M LED is off, the stack member is not the
master unit. The Stack No. panel displays the unit number for the stack
member. If a switch is not part of a stack (in other words, it is a stack of one
switch), the M LED is illuminated, and the unit number is displayed.

N3000 Series Back Panel
The following images show the back panels of the N3000 switches.
Figure 3-11. N3000 Back Panel
Fan Vents

Dual 10G Slots for SFP+ or
10GBASE-T Modules

Figure 3-12. N3024P/N3048P Back Panel

106

Hardware Overview

AC Power
Receptacle

Figure 3-13.

N3048 Mini-SAS Stacking Ports Close-up

Mini-SAS stacking ports

The term mini-SAS refers to the stacking port cable connections shown in
Figure 3-13. See "Managing a Switch Stack" on page 171 for information on
using the mini-SAS ports to connect switches.
Expansion Slots for Plug-in Modules

One expansion slot is located on the back of the N3000 models and can
support the following modules:
•

10GBASE-T module

•

SFP+ module

Each plug-in module has two ports. The plug-in modules include hot-swap
support, so you do not need to reboot the switch after you install a new
module.
Power Supplies

N3024, N3024F and N3048

N3024 series, N3024F and N3048 switches support two 200-watt Field
Replaceable Unit (FRU) power supplies which give full power redundancy for
the switch. The N3024, N3024F, and N3048 switches offer the V-lock feature
for users desiring the need to eliminate accidental power disconnection. The
V-lock receptacle on the Power Supply Unit (PSU) allows for the use of a
power cord that has the V-lock feature to create an integral secure locking
connection.

Hardware Overview

107

N3024P and N3048P

Dell Networking N3024P and N3048P switches support one or two 1100-watt
FRU power supplies. The N3024P switch is supplied with a single 715-watt
power supply (the default configuration) and supports an additional
1100-watt supply. For the N3048P switch, a single 1100-watt power supply is
supplied and another 1100 watt power supply can be added.
A single 1100-watt power supply can feed up to 24 PoE devices at full PoE+
power (950W). Dual-equipped switches will feed up to 48 PoE devices at full
PoE+ power (1800W), as well as provide power supply redundancy.
NOTE: PoE power is dynamically allocated by default. Not all ports will require the
full PoE+ power.
CAUTION: Remove the power cable from the power supplies prior to removing
the power supply module itself. Power must not be connected prior to insertion in
the chassis.
Ventilation System

Two fans cool the N3000 switches. The N3000 switches additionally have a
fan in each internal power supply. The N3000 fan is a FRU.
Information Tag

The back panel includes a slide-out label panel that contains system
information, such as the Service Tag, MAC address, and so on.

108

Hardware Overview

LED Definitions
This section describes the LEDs on the front and back panels of the switch.
Port LEDs

Each port on an N3000 series switch includes two LEDs. One LED is on the
left side of the port, and the second LED is on the right side of the port. This
section describes the LEDs on the switch ports.
100/1000/10000Base-T Port LEDs

Each 100/1000/10000Base-T port has two LEDs. Figure 3-20 illustrates the
100/1000/10000Base-T port LEDs.
Figure 3-14.

100/1000/10000Base-T Port LEDs

Link/SPD

Activity

Hardware Overview

109

Table 3-16 shows the 100/1000/10000Base-T port LED definitions.
Table 3-7.

100/1000/10000Base-T Port Definitions

LED

Color

Link/SPD LED Off

Definition
There is no link.

Solid yellow

The port is operating at 10/100 Mbps.

Solid green

The port is operating at 1000 Mbps.

Activity LED
(on non-PoE
switches)

Off

There is no current transmit/receive activity.

Blinking green

The port is actively transmitting/receiving.

Activity/PoE
LED (on PoE
switches)

Off

There is no current transmit/receive activity
and PoE power is off.

Blinking green

The port is actively transmitting/receiving and
PoE power is off.

Blinking yellow

The port is actively transmitting/receiving and
PoE power is on.

Solid yellow

There is no current transmit/receive activity
and PoE power is on.

Module Bay LEDs

The following tables describe the purpose of each of the module bay LEDs
when SFP+ and 10GBaseT modules are used.
Table 3-8.

SFP+ Module LED Definitions

LED

Color

Link/SPD LED Off

Activity LED

110

Definition
There is no link.

Solid green

The port is operating at 10 Gbps.

Solid amber

The port is operating at 1000 Mbps.

Off

There is no current transmit/receive activity.

Blinking green

The port is actively transmitting/receiving.

Hardware Overview

Table 3-9.

10GBase-T Module LED Definitions

LED

Color

Link/SPD LED Off

Activity LED

Definition
There is no link.

Solid green

The port is operating at 10 Gbps.

Solid amber

The port is operating at 100/1000 Mbps.

Off

There is no current transmit/receive activity.

Blinking green

The port is actively transmitting/receiving.

Table 3-10. Stacking Port LED Definitions
LED

Color

Definition

Link LED

Off

There is no link.

Solid green

The port is actively transmitting/receiving.

Off

There is no current transmit/receive activity.

Blinking green

The port is actively transmitting/receiving.

Activity LED

Table 3-11. OOB Port LED Definitions
LED

Color

Link/SPD LED Off

Activity LED

Definition
There is no link.

Solid green

The port is actively transmitting/receiving at
1000 Mbps.

Solid amber

The port is actively transmitting/receiving at
10/100 Mbps.

Off

There is no current transmit/receive activity.

Blinking green

The port is actively transmitting/receiving.

Hardware Overview

111

Table 3-12. Console Port LED Definitions
LED

Color

Definition

Link/SPD LED Off

There is no link.

Solid green

A link is present.

System LEDs

The system LEDs, located on the back panel, provide information about the
power supplies, thermal conditions, and diagnostics.
Table 3-21 shows the System LED definitions for the N3000 series switches.
Table 3-13. System LED Definitions
LED

Color

Definition

Status

Solid green

Normal operation.

Blinking green

The switch is booting

Solid red

A critical system error has occurred.

Blinking red

A noncritical system error occurred (fan or power
supply failure).

Off

There is no power or the switch has experienced a
power failure.

Solid green

Power to the switch is on.

Blinking green

The switch locator function is enabled.

Solid green

The fan is powered and is operating at the expected
RPM.

Solid red

A fan failure has occurred.

Stack
master

Off

The switch is in stand-alone mode.

Solid green

The switch is master for the stack.

Temp

Solid green

The switch is operating below the threshold
temperature.

Solid red

The switch temperature exceeds the threshold of 75°C.

Power 1,
Power 2

Fan

Stack No. –

112

Hardware Overview

Switch ID within the stack.

Power Consumption for N3000 Series PoE Switches
Table 3-14 shows power consumption data for the PoE-enabled switches.
Table 3-14. N3000 Series Power Consumption
Model

Input
Voltage

Power Supply
Configuration

Max Steady
Current
Consumption (A)

Max Steady
Power (W)

N3024P

100V

PSU1+PSU2

13.1

1310.0

110V

PSU1+PSU2

11.7

1287.0

120V

PSU1+PSU2

10.6

1272.0

220V

PSU1+PSU2

5.6

1232.0

240V

PSU1+PSU2

5.2

1240.8

100V

PSU1+PSU2

21.8

2180.0

110V

PSU1+PSU2

19.5

2145.0

120V

PSU1+PSU2

17.8

2136.0

220V

PSU1+PSU2

9.31

2048.2

240V

PSU1+PSU2

8.6

2064.0

N3048P

The PoE power budget for each interface is controlled by the switch firmware.
The administrator can limit the power supplied on a port or prioritize power
to some ports over others. Table 3-15 shows the power budget data.

Hardware Overview

113

Table 3-15. N3000 Series PoE Power Budget Limit
One PSU Support

Two PSUs Support

Model
Name

System Power
Max. PSU
POE+ Power
Max. Dissipation Output Ability Turn-on Limitation

Max. PSUs
POE+ Power
Output Ability Turn-on Limitation

N3024P

110W

715W

715W

Power budget is
550W:
The total POE
supplied power
must not exceed
550W.

N3048P

140W

1100W

Power budget is
950W:
The total POE
supplied power
must not exceed
950W.

114

Hardware Overview

Power budget is
1100W:
All PoE+ ports can
supply maximum
power.

2200W

Power budget is
1900W:
All PoE+ ports can
supply maximum
power.

Dell Networking N4000 Series Switch Hardware
NOTE: PowerConnect 8100 has been renamed N4000. Both PowerConnect 8100
and N4000 can run firmware versions 6.1 and beyond. N4000 cannot run firmware
prior to version 6.1.
This section contains information about device characteristics and modular
hardware configurations for the N4000 series switches.

Front Panel
The N4000 series front panel includes the following features:
•

Switch ports

•

Module bay that supports the following modules:
–

2 x 40 Gig QSFP (each QSFP may be configured as 4 x 10 Gig ports)

–

4 x SFP+ module

–

4 x 10GBaseT module

See "Hot-Pluggable Interface Modules" on page 117 for more information.
•

USB port

•

Reset button

•

Port and system LEDs

•

Stack LED

The N4032 front panel provides 32 x 10GbE copper ports that support up to
100M of CAT-6A UTP cabling. The N4032F provides 32 SFP+ ports
supporting SFP+ and SFP transceivers.

Hardware Overview

115

Figure 3-15. N4024 Front Panel

10GbE Copper Ports

Module bay
USB port

Figure 3-16. N4024F Front Panel

10GbE Fiber Ports

Module bay
USB port

N4032 and N4032F switches can be stacked with other N4000 switches using
10G or 40G SFP+ or QSFP modules in the module bay.
The N4064 front panel provides 64 x 10GbE copper ports and two fixed
QSFP ports, each supporting 4 x 10G or 1 x 40G connections. The N4064F
front panel provides 64 SFP+ ports supporting SFP+ and SFP transceivers
plus two fixed QSFP ports, each supporting 4 x 10G or 1 x 40G connections.

116

Hardware Overview

Figure 3-17.

N4064 Front Panel
Module bay

10GbE Copper Ports

Figure 3-18.

USB port

Fixed QSFP
ports

N4064F Front Panel
Module bay

10GbE Fiber Ports

USB port

Fixed QSFP
ports

The N4064 and N4064F switches can be stacked with other N4000 switches
using the 10G or 40G SFP+ or QSFP modules in the module bay or fixed
QSFP ports.
Hot-Pluggable Interface Modules

The N4032, N4032F, N4064, and N4064F switches support the following hotpluggable interface modules:
•

N4000-QSFP — 2 x 40G QSFP port module - defaults to 2 x 40G

•

N4000-SFP+ — 4 x SFP+ port module - defaults to 4 x 10G mode

•

N4000-10GBT — 4 x 10GBase-T ports module - defaults to 4 x 10G mode

•

Blank module — defaults to 10G mode
Hardware Overview

117

A reboot is necessary when a hot-pluggable module is replaced with a module
of different type. Specifically, changing from a 40G module to a 10G module
or from a 10G module to a 40G module requires a reboot. Plug-in modules
with any port configured as a stacking port are not hot-swappable. Remove
the stack-port configuration from a slot before plugging in a module.
You must execute a no slot or clear config command prior to inserting the
new module. Note that changing the role of a port from stacking to Ethernet
or vice-versa also requires a switch reboot.
If a no slot command is not issued prior to inserting a module, a message
such as the following will appear:
Card Mismatch: Unit:1 Slot:1 Inserted-Card: Dell 2
Port QSFP Expansion Card Config-Card: Dell 4 Port
10GBase-T Expansion Card
The following sections provides details on each module.
Quad-Port SFP (QSFP) Uplink Module

The QSFP module supports features four ports that support 10G SFP+
transceivers. The QSFP module supports the following features:
•

Four 10G ports with quad-breakout/QBO cable or one 40G port

•

Front-panel port status LEDs

The QSFP interfaces can be used for stacking. Stacking is supported at
distances of up to 100M.
Quad-Port SFP+ Uplink Module

The N4000-SFP+ module features four SFP+ ports, each providing the
following features:
•

SFP+ optical interfaces

•

SFP+ copper twinax interface

•

Front-panel port status LEDs

The SFP+ connections can be used for stacking. Stacking is supported at
distances of up to 100M.

118

Hardware Overview

10GBase-T Copper Uplink Module

The 10GBase-T copper module features four copper ports that can support
10GbE/1GbE/100MbE switching and provides following features:
•

Complies with IEEE802.3z, IEEE 802.3, IEEE802.3u, IEEE802.3ab,
IEEE802.3az, IEEE802.3an

•

Four 10GBase-T/1GBase-T/100MBase-T copper ports.

•

Front panel port status LEDs

USB Port

The Type-A, female USB port supports a USB 2.0-compliant flash memory
drive. The N4000 switch can read or write to a flash drive with a single
partition formatted as FAT-32. You can use a USB flash drive to copy switch
configuration files and images between the USB flash drive and the switch.
You can also use the USB flash drive to move and copy configuration files and
images from one switch to other switches in the network. Deletion of files on
the USB drive is not supported.
The USB port does not support any other type of USB device.
Port and System LEDs

The front panel contains light emitting diodes (LEDs) to indicate port status.
For information about the status that the LEDs indicate, see "LED
Definitions" on page 121.
SFP+ and QSFP+ Ports

SFP+ and QSFP+ ports support Dell-qualified transceivers. The default
behavior is to log a message and generate an SNMP trap on insertion or
removal of an optic that is not qualified by Dell. This message and trap can be
suppressed by using the service unsupported-transceiver command.

N4000 Back Panel
The N4000 series back panel has the following features:
•

Console port

•

Out-of-band management port

•

Power Supplies

Hardware Overview

119

•

Ventilation System

The following image show the back panel of the N4000 series switches.
Figure 3-19. N4000 Series Back Panel
RJ-45 serial console port

AC power

OOB Ethernet port

Fans

AC power

Console Port

The console port is for management through a serial interface. This port
provides a direct connection to the switch and allows you to access the CLI
from a console terminal connected to the port through the provided serial
cable (RJ-45 to female DB-9 connectors).
The console port supports asynchronous data of eight data bits, one stop bit, no
parity bit, and no flow control. The default baud rate is 9600 bps.
Out-of-Band Management Port

The Out-of-Band (OOB) management port is a 10/100/1000BASE-T
Ethernet port dedicated to remote switch management. Traffic on this port is
segregated from operational network traffic on the switch ports and cannot be
switched or routed to or from the operational network.
Power Supplies

Each N4000 series switch has two power supplies for redundant or
loadsharing operation. Each power supply can support 300W.

120

Hardware Overview

CAUTION: Remove the power cable from the modules prior to removing the
module itself. Power must not be connected prior to insertion in the chassis.
Ventilation System

The N4000 series switches have two fans. Each switch also has four thermal
sensors and a fan speed controller, which can be used to control FAN speeds.
You can verify operation by observing the LEDs.

LED Definitions
This section describes the LEDs on the front and back panels of the switch.
Port LEDs

Each port on a N4000 series switch includes two LEDs. One LED is on the
left side of the port, and the second LED is on the right side of the port. This
section describes the LEDs on the switch ports.
100/1000/10000Base-T Port LEDs

Each 100/1000/10000Base-T port has two LEDs. Figure 3-20 illustrates the
100/1000/10000Base-T port LEDs.
Figure 3-20.

100/1000/10000Base-T Port LEDs

Link

Activity

Hardware Overview

121

Table 3-16 shows the 100/1000/10000Base-T port LED definitions.
Table 3-16. 100/1000/10000Base-T Port Definitions
LED

Color

Definition

Link LED

Off

There is no link.

Solid green

The port is operating at 10 Gbps.

Solid amber

The port is operating at 100/1000 Mbps.

Off

There is no current transmit/receive activity.

Blinking green

The port is actively transmitting/receiving.

Activity LED

Module Bay LEDs

The following tables describe the purpose of each of the module bay LEDs
when SFP+, 10GBase-T, and QSFP modules are used.
Table 3-17. SFP+ Module LED Definitions
LED

Color

Definition

Link LED

Off

There is no link.

Solid green

The port is operating at 10 Gbps.

Solid amber

The port is operating at 100/1000 Mbps.

Off

There is no current transmit/receive activity.

Blinking green

The port is actively transmitting/receiving.

Activity LED

Table 3-18. 10GBase-T Module LED Definitions
LED

Color

Definition

Link LED

Off

There is no link.

Solid green

The port is operating at 10 Gbps.

Solid amber

The port is operating at 100/1000 Mbps.

Off

There is no current transmit/receive activity.

Blinking green

The port is actively transmitting/receiving.

Activity LED

122

Hardware Overview

Table 3-19. QSFP Module LED Definitions
LED

Color

Definition

Link LED

Off

There is no link.

Solid green

The port is operating at 40 Gbps.

Solid amber

The port is operating at other speeds.

Off

There is no current transmit/receive activity.

Blinking green

The port is actively transmitting/receiving.

Activity LED

Out-of-Band Ethernet Management Port LEDs

Table 3-20 shows the LED definitions for the OOB Ethernet management
port.
Table 3-20. OOB Ethernet Management Port LED Definitions
LED

Color

Definition

Link LED

Off

There is no link.

Solid green

The port is operating at 1000 Mbps.

Solid amber

The port is operating at 10/100 Mbps.

Off

There is no current transmit/receive activity.

Blinking green

The port is actively transmitting/receiving.

Activity LED

System LEDs

The system LEDs, located on the back panel, provide information about the
power supplies, thermal conditions, and diagnostics.

Hardware Overview

123

Table 3-21 shows the System LED definitions for the N4000 series switches.
Table 3-21. System LED Definitions—N4000 Series Switches
LED

Color

Definition

System

Blinking blue

The switch is booting

Solid red

A critical system error has occurred.

Blinking red

A noncritical system error occurred (fan or power
supply failure).

Off

The switch is operating at normal temperature.

Solid amber

The thermal sensor’s system temperature threshold of
75°C has been exceeded.

Off

The switch is operating normally

Blinking green

A diagnostic test is running.

Solid green

The fan is powered and is operating at the expected
RPM.

Solid red

A fan failure has occurred.

Solid blue

The switch is in stacking master mode.

Solid amber

The switch is in stacking slave mode.

Off

The switch is in stand-alone mode.

Blinking green

The locator function is enabled.

Solid green

The locator function is disabled.

Temp

Diag
Fan

Stack

Locator

124

Hardware Overview

Switch MAC Addresses
The switch allocates MAC addresses from the Vital Product Data information
stored locally in flash. MAC addresses are used as follows:
Table 3-22. MAC Address Use
Base

switch address, Layer 2

Base + 1

Out-of-band port (not available on N20xx switches)

Base + 3

Layer 3

Shown below are three commands that display the MAC addresses used by
the switch:
console#show system
System Description: Dell Ethernet Switch
System Up Time: 0 days, 00h:05m:11s
System Contact:
System Name:
System Location:
Burned In MAC Address: 001E.C9F0.004D
System Object ID: 1.3.6.1.4.1.674.10895.3042
System Model ID: N4032
Machine Type: N4032
Temperature Sensors:
Unit

Description

---1
1
1
1

----------MAC
CPU
PHY (left side)
PHY (right side)

Temperature
(Celsius)
----------32
31
26
29

Status
-----Good
Good
Good
Good

Fans:
Unit
---1
1
1
1
1
1

Description
----------Fan 1
Fan 2
Fan 3
Fan 4
Fan 5
Fan 6

Status
-----OK
OK
OK
OK
OK
No Power

Power Supplies:
Unit

Description

----

-----------

Status

-----------

Average
Power
(Watts)
----------

Current
Power
(Watts)
--------

Since
Date/Time
-------------------

Hardware Overview

125

1
1
1

System
Main
Secondary

OK
OK
No Power

42.0
N/A
N/A

43.4
N/A
N/A

04/06/2001 16:36:16
01/01/1970 00:00:00

USB Port Power Status:
---------------------Device Not Present
console#show ip interface out-of-band
IP Address.....................................
Subnet Mask....................................
Default Gateway................................
Configured IPv4 Protocol.......................
Burned In MAC Address..........................

10.27.21.29
255.255.252.0
10.27.20.1
DHCP
001E.C9F0.004E

console#show ip interface vlan 1
Routing Interface Status.......................
Primary IP Address.............................
Method.........................................
Routing Mode...................................
Administrative Mode............................
Forward Net Directed Broadcasts................
Proxy ARP......................................
Local Proxy ARP................................
Active State...................................
MAC Address....................................
Encapsulation Type.............................
IP MTU.........................................
Bandwidth......................................
Destination Unreachables.......................
ICMP Redirects.................................

126

Hardware Overview

Down
1.1.1.2/255.255.255.0
Manual
Enable
Enable
Disable
Enable
Disable
Inactive
001E.C9F0.0050
Ethernet
1500
10000 kbps
Enabled
Enabled

Using Dell OpenManage Switch
Administrator

4

This section describes how to use the Dell OpenManage Switch
Administrator application. The topics covered in this section include:
•

About Dell OpenManage Switch Administrator

•

Starting the Application

•

Understanding the Interface

•

Using the Switch Administrator Buttons and Links

•

Defining Fields

About Dell OpenManage Switch Administrator
Dell OpenManage Switch Administrator is a web-based tool to help you
manage and monitor a Dell Networking N2000, N3000, and N4000 series
switches. Table 4-1 lists the web browsers that are compatible with Dell
OpenManage Switch Administrator. The browsers have been tested on a PC
running the Microsoft Windows operating system.
Table 4-1.

Compatible Browsers

Browser

Version

Internet Explorer

v9

Mozilla Firefox

v14

Safari

v5.0

Chrome

v21

NOTE: Additional operating systems and browsers might be compatible but have
not been explicitly tested with Dell OpenManage Switch Administrator.

Using Dell OpenManage Switch Administrator

127

Starting the Application
To access the Dell OpenManage Switch Administrator and log on to the
switch:
1 Open a web browser.
2 Enter the IP address of the switch in the address bar and press .
For information about assigning an IP address to a switch, see "Setting the
IP Address and Other Basic Network Information" on page 147.
3 When the Login window displays, enter a user name and password.
Passwords are both case sensitive and alpha-numeric.
Figure 4-1. Login Screen

NOTE: The switch is not configured with a default user name or password.
You must connect to the CLI by using the console port to configure the initial
user name and password. For information about connecting to the console,
see "Console Connection" on page 135. For information about creating a user
and password, see "Configuring Authentication, Authorization, and
Accounting" on page 207.
4 Click Submit.
128

Using Dell OpenManage Switch Administrator

5 The Dell OpenManage Switch Administrator home page displays.
The home page is the Device Information page, which contains a
graphical representation of the front panel of the switch. For more
information about the home page, see "Device Information" on page 249.

Understanding the Interface
The Dell OpenManage Switch Administrator interface contains the following
components:
•

Navigation panel — Located on the left side of the page, the navigation
pane provides an expandable view of features and their components.

•

Configuration and status options — The main panel contains the fields
you use to configure and monitor the switch.

•

Page tabs — Some pages contain tabs that allow you to access additional
pages related to the feature.

•

Command buttons — Command buttons are located at the bottom of the
page. Use the command buttons to submit changes, perform queries, or
clear lists.

•

Save, Print, Refresh, and Help buttons — These buttons appear on the
top-right side of the main panel and are on every page.

•

Support, About, and Logout links — These links appear at the top of every
page.

Using Dell OpenManage Switch Administrator

129

Figure 4-2. Switch Administrator Components
Navigation Panel

Page Tabs

Links

Configuration and Status Options

130

Using Dell OpenManage Switch Administrator

Save, Print, Refresh, Help

Command Button

Using the Switch Administrator Buttons and Links
Table 4-2 describes the buttons and links available from the Dell
OpenManage Switch Administrator interface.
Table 4-2.

Button and Link Descriptions

Button or Link

Description

Support

Opens the Dell Support page at support.dell.com

About

Contains the version and build number and Dell copyright
information.

Log Out

Logs out of the application and returns to the login screen.

Save

Saves the running configuration to the startup configuration.
When you click Apply, changes are saved to the running
configuration. When the system boots, it loads the startup
configuration. Any changes to the running configuration that were
not saved to the startup configuration are lost across a power cycle.

Print

Opens the printer dialog box that allows you to print the current
page. Only the main panel prints.

Refresh

Refreshes the screen with the current information.

Help

Online help that contains information to assist in configuring and
managing the switch. The online help pages are context sensitive.
For example, if the IP Addressing page is open, the help topic for
that page displays if you click Help.

Apply

Updates the running configuration on the switch with the changes.
Configuration changes take effect immediately.

Clear

Resets statistic counters and log files to the default configuration.

Query

Queries tables.

Left arrow and
Right arrow

Moves information between lists.

NOTE: A few pages contain a button that occurs only on that page. Page-specific
buttons are described in the sections that pertain to those pages.

Using Dell OpenManage Switch Administrator

131

Defining Fields
User-defined fields can contain 1–159 characters, unless otherwise noted on
the Dell OpenManage Switch Administrator web page.
All characters may be used except for the following:
•

\

•

/

•

:

•

*

•

?

•

<

•

>

•

|

Understanding the Device View
The Device View shows various information about switch. This graphic
appears on the OpenManage Switch Administrator Home page, which is the
page that displays after a successful login. The graphic provides information
about switch ports and system health.
Figure 4-3. Dell Networking N3048 Device View

Using the Device View Port Features
The switching-port coloring indicates if a port is currently active. Green
indicates that the port has a link, red indicates that an error has occurred on
the port, and blue indicates that the link is down. Each port image is a
hyperlink to the Port Configuration page for the specific port.

132

Using Dell OpenManage Switch Administrator

Using the Device View Switch Locator Feature
The Device View graphic includes a Locate button and a drop-down menu of
timer settings. When you click Locate, the switch locator LED on the back
panel of the switch blinks for the number of seconds selected from the timer
menu. The green, blinking LED on the back of the switch can help you or a
technician near the switch identify the physical location of the switch within
a room or rack full of switches. After you click the Locate button it turns
green and remains green while the LED is blinking.
NOTE: You can also issue the locate command from the CLI to enable the
locator LED.

Using Dell OpenManage Switch Administrator

133

134

Using Dell OpenManage Switch Administrator

5

Using the Command-Line Interface

This section describes how to use the Command-Line Interface (CLI) on a
Dell Networking N2000, N3000, and N4000 series switches.
The topics covered in this section include:
•

Accessing the Switch Through the CLI

•

Understanding Command Modes

•

Entering CLI Commands

Accessing the Switch Through the CLI
The CLI provides a text-based way to manage and monitor the Dell
Networking N2000, N3000, and N4000 series switches. You can access the
CLI by using a direct connection to the console port or by using a Telnet or
SSH client.
To access the switch by using Telnet or Secure Shell (SSH), the switch must
have an IP address, and the management station you use to access the device
must be able to ping the switch IP address.
For information about assigning an IP address to a switch, see "Setting the IP
Address and Other Basic Network Information" on page 147.

Console Connection
Use the following procedures to connect to the CLI by connecting to the
console port. For more information about creating a serial connection, see the
Getting Started Guide available at support.dell.com/manuals.
1 Connect the DB-9 connector of the supplied serial cable to a management
station, and connect the RJ-45 connector to the switch console port.
On N2000 and N3000 series switches, the console port is located on the
right side of the front panel and is labeled with the |O|O| symbol. On the
N4000 series switches, it is located on the back panel above the OOB
Ethernet port.

Using the Command-Line Interface

135

NOTE: For a stack of switches, be sure to connect to the console port on the
Master switch. The Master LED (M) is illuminated on the stack Master.

2 Start the terminal emulator, such as Microsoft HyperTerminal, and select
the appropriate serial port (for example, COM 1) to connect to the
console.
3 Configure the management station serial port with the following settings:
•

Data rate — 9600 baud.

•

Data format — 8 data bits

•

Parity — None

•

Stop bits — 1

•

Flow control — None

4 Power on the switch (or stack).
After the boot process completes, the console> prompt displays, and
you can enter commands.
NOTE: By default, no authentication is required for console access.
However, if an authentication method has been configured for console port
access, the User: login prompt displays.

Telnet Connection
Telnet is a terminal emulation TCP/IP protocol. ASCII terminals can be
virtually connected to the local device through a TCP/IP protocol network.
Telnet connections are enabled by default, and the Telnet port number is 23.
The switch supports up to four simultaneous Telnet sessions. All CLI
commands can be used over a Telnet session.
NOTE: SSH, which is more secure than Telnet, is disabled by default.
To connect to the switch using Telnet, the switch must have an IP address,
and the switch and management station must have network connectivity. You
can use any Telnet client on the management station to connect to the
switch.
136

Using the Command-Line Interface

You can also initiate a Telnet session from the OpenManage Switch
Administrator. For more information, see "Initiating a Telnet Session from the
Web Interface" on page 288.

Understanding Command Modes
The CLI groups commands into modes according to the command function.
Each of the command modes supports specific software commands. The
commands in one mode are not available until you switch to that particular
mode, with the exception of the User EXEC mode commands. You can
execute the User EXEC mode commands in the Privileged EXEC mode.
To display the commands available in the current mode, enter a question
mark (?) at the command prompt. In each mode, a specific command is used
to navigate from one command mode to another.
The main command modes include the following:
•

User EXEC — Commands in this mode permit connecting to remote
devices, changing terminal settings on a temporary basis, performing basic
tests, and listing system information.

•

Privileged EXEC — Commands in this mode permit you to view all switch
settings and to enter the global configuration mode.

•

Global Configuration — Commands in this mode manage the device
configuration on a global level and apply to system features, rather than to
a specific protocol or interface.

•

Interface Configuration — Commands in this mode configure the settings
for a specific interface or range of interfaces.

•

VLAN Configuration — Commands in this mode create and remove
VLANs and configure IGMP/MLD Snooping parameters for VLANs.

The CLI includes several additional command modes. For more information
about the CLI command modes, including details about all modes, see the
CLI Reference Guide.
Table 5-1 describes how to navigate between CLI Command Mode and lists
the prompt that displays in each mode.

Using the Command-Line Interface

137

Table 5-1.

Command Mode Overview

Command Mode

Access Method

Command Prompt

User EXEC

The user is
console>
automatically in
User EXEC
mode unless the
user is defined as
a privileged user.

Exit or Access
Previous Mode
logout

Privileged EXEC From User
console#
EXEC mode,
enter the enable
command

Use the exit
command, or press
Ctrl-Z to return to
User EXEC mode.

Global
Configuration

From Privileged console(config)#
EXEC mode, use
the configure
command.

Use the exit
command, or press
Ctrl-Z to return to
Privileged EXEC
mode.

Interface
Configuration

From Global
Configuration
mode, use the
interface
command and
specify the
interface type
and ID.

To exit to Global
Configuration
mode, use the exit
command, or press
Ctrl-Z to return to
Privileged EXEC
mode.

138

console(configif)#

Using the Command-Line Interface

Entering CLI Commands
The switch CLI uses several techniques to help you enter commands.

Using the Question Mark to Get Help
Enter a question mark (?) at the command prompt to display the commands
available in the current mode.
console(config-vlan)#?
exit
help
ip
ipv6
protocol
vlan

To exit from the mode.
Display help for various special keys.
Configure IP parameters.
Configure IPv6 parameters.
Configure the Protocols associated with
particular Group Ids.
Create a new VLAN or delete an existing
VLAN.

Enter a question mark (?) after each word you enter to display available
command keywords or parameters.
console(config)#vlan ?


protocol

<1-4093> - separate non-consecutive IDs
with ',' and no spaces; Use '-' for
range.
Configure Protocol Based VLAN
parameters.

If the help output shows a parameter in angle brackets, you must replace the
parameter with a value.
console#telnet ?


Enter the valid host IP
address or Host Name.

Using the Command-Line Interface

139

If there are no additional command keywords or parameters, or if additional
parameters are optional, the following message appears in the output:


Press enter to execute the command.

You can also enter a question mark (?) after typing one or more characters of a
word to list the available command or parameters that begin with the letters,
as shown in the following example:
console#show po?
policy-map

port

ports

Using Command Completion
The CLI can complete partially entered commands when you press the
 or  key.
console#show run
console#show running-config
If the characters you entered are not enough for the switch to identify a single
matching command, continue entering characters until the switch can
uniquely identify the command. Use the question mark (?) to display the
available commands matching the characters already entered.

Entering Abbreviated Commands
To execute a command, you need to enter enough characters so that the
switch can uniquely identify a command. For example, to enter Global
Configuration mode from Privileged EXEC mode, you can enter conf instead
of configure.
console#conf
console(config)#

Negating Commands
For many commands, the prefix keyword no is entered to cancel the effect of
a command or reset the configuration to the default value. Many
configuration commands have this capability.

140

Using the Command-Line Interface

Command Output Paging
Lines are printed on the screen up to the configured terminal length limit
(default 24). Use the space bar to show the next page of output or the carriage
return to show the next line of output. Setting the terminal length to zero
disables paging. Command output displays until no more output is available.

Understanding Error Messages
If you enter a command and the system is unable to execute it, an error
message appears. Table 5-2 describes the most common CLI error messages.
Table 5-2.

CLI Error Messages

Message Text

Description

% Invalid input
detected at '^'
marker.

Indicates that you entered an incorrect or
unavailable command. The carat (^) shows
where the invalid text is detected. This message
also appears if any of the parameters or values are
not recognized.

Command not found /
Incomplete command.
Use ? to list
commands.

Indicates that you did not enter the required
keywords or values.

Ambiguous command

Indicates that you did not enter enough letters to
uniquely identify the command.

If you attempt to execute a command and receive an error message, use the
question mark (?) to help you determine the possible keywords or parameters
that are available.

Recalling Commands from the History Buffer
Every time a command is entered in the CLI, it is recorded in an internally
managed Command History buffer. By default, the history buffer is enabled
and stores the last 10 commands entered. These commands can be recalled,
reviewed, modified, and reissued. This buffer is not preserved after switch
resets.

Using the Command-Line Interface

141

Table 5-3.

History Buffer Navigation

Keyword

Source or Destination

Up-arrow key

Recalls commands in the history buffer, beginning with the most
recent command. Repeats the key sequence to recall successively
older commands.

+

Down-arrow key + 142 Returns to more recent commands in the history buffer after recalling commands with the up-arrow key. Repeating the key sequence recalls more recent commands in succession. Using the Command-Line Interface 6 Default Settings This section describes the default settings for many of the software features on the Dell Networking series switches. Table 6-1. Default Settings Feature Default IP address None Subnet mask None Default gateway None DHCP client Enabled on out-of-band (OOB) interface. VLAN 1 Members All switch ports SDM template Dual IPv4 and IPv6 routing Users None Minimum password length 8 characters IPv6 management mode Enabled SNTP client Disabled Global logging Enabled Switch auditing Disabled CLI command logging Disabled Web logging Disabled SNMP logging Disabled Console logging Enabled (Severity level: debug and above) RAM logging Enabled (Severity level: debug and above) Persistent (FLASH) logging Disabled DNS Enabled (No servers configured) SNMP Enabled (SNMPv1) Default Settings 143 Table 6-1. Default Settings (Continued) Feature Default SNMP Traps Enabled Auto Configuration Enabled Auto Save Disabled Stacking Enabled Nonstop Forwarding on the Stack Enabled sFlow Enabled ISDP Enabled (Versions 1 and 2) RMON Enabled TACACS+ Not configured RADIUS Not configured SSH/SSL Disabled Telnet Enabled Denial of Service Protection Disabled Captive Portal Disabled Dot1x Authentication (IEEE 802.1X) Disabled MAC-Based Port Security All ports are unlocked Access Control Lists (ACL) None configured IP Source Guard (IPSG) Disabled DHCP Snooping Disabled Dynamic ARP Inspection Disabled Protected Ports (Private VLAN Edge) None Energy Detect Mode Disabled EEE Lower Power Mode Disabled PoE Plus (POE switches) Auto Flow Control Support (IEEE 802.3x) Enabled Head of Line Blocking Prevention Disabled Maximum Frame Size 1500 bytes 144 Default Settings Table 6-1. Default Settings (Continued) Feature Default Auto-MDI/MDIX Support Enabled Auto Negotiation Enabled Advertised Port Speed Maximum Capacity Broadcast Storm Control Disabled Port Mirroring Disabled LLDP Enabled LLDP-MED Disabled MAC Table Address Aging 300 seconds (Dynamic Addresses) Cisco Protocol Filtering (LLPF) No protocols are blocked DHCP Layer 2 Relay Disabled Default VLAN ID 1 Default VLAN Name Default GVRP Disabled GARP Timers Leave: 60 centiseconds Leave All: 1000 centiseconds Join: 20 centiseconds Voice VLAN Disabled Guest VLAN Disabled RADIUS-assigned VLANs Disabled Double VLANs Disabled Spanning Tree Protocol (STP) Enabled STP Operation Mode IEEE 802.1w Rapid Spanning Tree Optional STP Features Disabled STP Bridge Priority 32768 Multiple Spanning Tree Disabled Link Aggregation No LAGs configured LACP System Priority 1 Default Settings 145 Table 6-1. Default Settings (Continued) Feature Default Routing Mode Disabled OSPF Admin Mode Enabled OSPF Router ID 0.0.0.0 IP Helper and UDP Relay Enabled RIP Enabled VRRP Disabled Tunnel and Loopback Interfaces None IPv6 Routing Disabled DHCPv6 Disabled OSPFv3 Enabled DiffServ Enabled Auto VoIP Disabled Auto VoIP Traffic Class 6 PFC Disabled; no classifications configured. DCBx version Auto detect iSCSI Enabled MLD Snooping Enabled IGMP Snooping Enabled IGMP Snooping Querier Disabled GMRP Disabled IPv4 Multicast Disabled IPv6 Multicast Disabled 146 Default Settings Setting the IP Address and Other Basic Network Information 7 This chapter describes how to configure basic network information for the switch, such as the IP address, subnet mask, and default gateway. The topics in this chapter include: • IP Address and Network Information Overview • Default Network Information • Configuring Basic Network Information (Web) • Configuring Basic Network Information (CLI) • Basic Network Information Configuration Example IP Address and Network Information Overview What Is the Basic Network Information? The basic network information includes settings that define the Dell Networking N2000, N3000, and N4000 series switches in relation to the network. Table 7-1 provides an overview of the settings this chapter describes. Table 7-1. Basic Network Information Feature Description IP Address On an IPv4 network, the a 32-bit number that uniquely identifies a host on the network. The address is expressed in dotted-decimal format, for example 192.168.10.1. Subnet Mask Determines which bits in the IP address identify the network, and which bits identify the host. Subnet masks are also expressed in dotted-decimal format, for example 255.255.255.0. Setting Basic Network Information 147 Table 7-1. Basic Network Information (Continued) Feature Description Default Gateway Typically a router interface that is directly connected to the switch and is in the same subnet. The switch sends IP packets to the default gateway when it does not recognize the destination IP address in a packet. DHCP Client Requests network information from a DHCP server on the network. Domain Name System (DNS) Server Translates hostnames into IP addresses. The server maintains a domain name databases and their corresponding IP addresses. Default Domain Name Identifies your network, such as dell.com. If you enter a hostname and do not include the domain name information, the default domain name is automatically appended to the hostname. Host Name Mapping Allows you to statically map an IP address to a hostname. Additionally, this chapter describes how to view host name-to-IP address mappings that have been dynamically learned by the system. Why Is Basic Network Information Needed? Dell Networking series switches are layer 2/3 managed switches. To manage the switch remotely by using a web browser or Telnet client, the switch must have an IP address, subnet mask, and default gateway. You must also configure a username and password to be able to log into the switch from a remote host. For information about configuring users, see "Configuring Authentication, Authorization, and Accounting" on page 207. If you manage the switch only by using the console connection, configuring an IP address and user is not required. In this case, disabling the Telnet server using the no ip telnet command is recommended. NOTE: The configuration example in this chapter includes commands to create an administrative user with read/write access. 148 Setting Basic Network Information Configuring the DNS information, default domain name, and host name mapping help the switch identify and locate other devices on the network and on the Internet. For example, to upgrade the switch software by using a TFTP server on the network, you must identify the TFTP server. If you configure the switch to use a DNS server to resolve hostnames into IP addresses, you can enter the hostname of the TFTP server instead of the IP address. It is often easier to remember a hostname than an IP address, and if the IP address is dynamically assigned, it might change from time-to-time. How Is Basic Network Information Configured? You must use a console-port connection to perform the initial switch configuration. When you boot the switch for the first time and the configuration file is empty, the Dell Easy Setup Wizard starts. The Dell Easy Setup Wizard is a CLI-based tool to help you perform the initial switch configuration. If you do not respond to the Dell Easy Setup Wizard prompt within 60 seconds, the console> prompt appears, and you enter User Configuration mode. For more information about performing the initial switch configuration by using the wizard, see the Getting Started Guide at support.dell.com/manuals. If you do not use the wizard to prompt you for the initial configuration information, you can enable the DHCP client on the switch to obtain network information from a DHCP server on your network, or you can statically assign the network information. After you configure the switch with an IP address and create a user account, you can continue to use the console connection to configure basic network information, or you can log on to the switch by using a Telnet client or a web browser. You can change the IP address information and configure additional network information from the remote system. What Is Out-of-Band Management and In-Band Management? The Dell Networking 3000 and 4000 series switches have an external port intended solely for management of the switch. This port is the out-of-band (OOB) management port. Traffic received on the OOB port is never switched or routed to any in-band port and is not rate limited. Likewise, traffic received on any in-band port is never forwarded or routed over the OOB port. The only applications available on the OOB port are protocols required to manage the Setting Basic Network Information 149 switch, for example Telnet, SSH, DHCP client, and TFTP. If using the out-ofband management port, it is strongly recommended that the port be connected only to a physically isolated secure management network. Alternatively, network administrators may choose to manage their network via the production network. This is in-band management. Because in-band management traffic is mixed in with production network traffic, it is subject to all of the filtering rules usually applied on a switched/routed port, such as ACLs and VLAN tagging, and is rate limited to protect against DoS attacks. You can assign an IP address or IPv6 addresses to the OOB management port and to any VLAN. By default, all ports are members of VLAN 1. If you assign an IP address to VLAN 1, you can connect to the switch management interface by using any of the front-panel switch ports. This is required to manage the N2000 switches over an Ethernet port. Dell recommends that you use the OOB port for remote management. The following list highlights some advantages of using OOB management instead of in-band management: • Traffic on the OOB port is passed directly to the switch CPU, bypassing the switching silicon. The OOB port is implemented as an independent NIC, which allows direct access to the switch CPU from the management network. • If the production network is experiencing problems, you can still access the switch management interface and troubleshoot issues. • Because the OOB port is intended to be physically isolated from the production network or deployed behind a firewall, configuration options are limited to just those protocols needed to manage the switch. Limiting the configuration options makes it difficult to accidentally cut off management access to the switch. DHCP can be enabled on the OOB interface and VLAN interfaces simultaneously, or you can configure static information. To configure static address information on the default VLAN, set the IP address and subnet mask on the VLAN interface and configure a global default gateway for the switch. Adjusting the Management Interface MTU When logging in to the Dell Networking switch using TCP, the switch negotiates the TCP Maximum Segment Size (MSS) using the minimum of the requested MSS or the MTU setting of the port. TCP packets are 150 Setting Basic Network Information transmitted from the switch with the DF (Don't Fragment) bit set in order to receive notification of fragmentation from any transit routers. Upon receiving an ICMP Destination Unreachable, Fragmentation needed but DF set notification, the switch will reduce the MSS. However, many firewalls block ICMP Destination Unreachable messages, which causes the destination to request the packet again until the connection times out. To resolve this issue, you can reduce the MSS setting to a more appropriate value on the local host or alternatively, you can set system MTU to a smaller value. Default Network Information NOTE: N2000 switches do not have an out-of-band interface. By default, no network information is configured. The DHCP client is enabled on the OOB interface by default on N3000 and N4000 switches. The DHCP client is enabled on VLAN 1 by default on the N2000 switches. DNS is enabled, but no DNS servers are configured. VLAN 1 does not have an IP address, subnet mask, or default gateway configured on N3000 and N4000 switches. Setting Basic Network Information 151 Configuring Basic Network Information (Web) This section provides information about the OpenManage Switch Administrator pages for configuring and monitoring basic network information on the Dell Networking N2000, N3000, and N4000 series switches. For details about the fields on a page, click at the top of the page. Out-of-Band Interface NOTE: N2000 switches do not have an out-of-band interface. Use the Out of Band Interface page to assign the out-of-band interface IP address and subnet mask or to enable/disable the DHCP client for address information assignment. DHCP is enabled by default on the OOB interface. The OOB interface must be configured on a subnet separate from the frontpanel port routing interfaces. The system default gateway must not share an address range/subnet with the OOB interface. The out-of-band interface may also be assigned an IPv6 address, either statically or via DHCP. In addition, the out-of-band port may be assigned an IPv6 address via the IPv6 auto-configuration process. To display the Out of Band Interface page, click System → IP Addressing → Out of Band Interface in the navigation panel. 152 Setting Basic Network Information Figure 7-1. Out of Band Interface To enable the DHCP client and allow a DHCP server on your network to automatically assign the network information to the OOB interface, select DHCP from the Protocol menu. If you statically assign the network information, make sure the Protocol menu is set to None. IP Interface Configuration (Default VLAN IP Address) Use the IP Interface Configuration page to assign the default VLAN IP address and subnet mask, the default gateway IP address, and to assign the boot protocol. To display the IP Interface Configuration page, click Routing → IP → IP Interface Configuration in the navigation panel. Setting Basic Network Information 153 Figure 7-2. IP Interface Configuration (Default VLAN) Assigning Network Information to the Default VLAN To assign an IP Address and subnet mask to the default VLAN: 1 From the Interface menu, select VLAN 1. 2 From the Routing Mode field, select Enable. 3 From the IP Address Configuration Method field specify whether to assign a static IP address (Manual) or use DHCP for automatic address assignment. 4 If you select Manual for the configuration method, specify the IP Address and Subnet Mask in the appropriate fields. 5 Click Apply. 154 Setting Basic Network Information NOTE: You do not need to configure any additional fields on the page. For information about VLAN routing interfaces, see "Configuring Routing Interfaces" on page 1021. Route Entry Configuration (Switch Default Gateway) Use the Route Entry Configuration page to configure the default gateway for the switch. The default VLAN uses the switch default gateway as its default gateway. The switch default gateway must not be on the same subnet as the OOB management port, as the OOB management port cannot route packets received on the front-panel ports. To display the Route Entry Configuration page, click Routing → Router → Route Entry Configuration in the navigation panel. Figure 7-3. Route Configuration (Default VLAN) Setting Basic Network Information 155 Configuring a Default Gateway for the Switch: To configure the switch default gateway: 1 Open the Route Entry Configuration page. 2 From the Route Type field, select Default. Figure 7-4. Default Route Configuration (Default VLAN) 3 In the Next Hop IP Address field, enter the IP address of the default gateway. 4 Click Apply. For more information about configuring routes, see "Configuring IP Routing" on page 1063. 156 Setting Basic Network Information Domain Name Server Use the Domain Name Server page to configure the IP address of the DNS server. The switch uses the DNS server to translate hostnames into IP addresses. To display the Domain Name Server page, click System → IP Addressing → Domain Name Server in the navigation panel. Figure 7-5. DNS Server To configure DNS server information, click the Add link and enter the IP address of the DNS server in the available field. Figure 7-6. Add DNS Server Setting Basic Network Information 157 Default Domain Name Use the Default Domain Name page to configure the domain name the switch adds to a local (unqualified) hostname. To display the Default Domain Name page, click System → IP Addressing → Default Domain Name in the navigation panel. Figure 7-7. Default Domain Name 158 Setting Basic Network Information Host Name Mapping Use the Host Name Mapping page to assign an IP address to a static host name. The Host Name Mapping page provides one IP address per host. To display the Host Name Mapping page, click System → IP Addressing → Host Name Mapping. Figure 7-8. Host Name Mapping To map a host name to an IP address, click the Add link, type the name of the host and its IP address in the appropriate fields, and then click Apply. Figure 7-9. Add Static Host Name Mapping Use the Show All link to view all configured host name-to-IP address mappings. Setting Basic Network Information 159 Dynamic Host Name Mapping Use the Dynamic Host Name Mapping page to view dynamic host entries the switch has learned. The switch learns hosts dynamically by using the configured DNS server to resolve a hostname. For example, if you ping www.dell.com from the CLI, the switch uses the DNS server to lookup the IP address of dell.com and adds the entry to the Dynamic Host Name Mapping table. To display the Dynamic Host Name Mapping page, click System → IP Addressing → Dynamic Host Name Mapping in the navigation panel. Figure 7-10. View Dynamic Host Name Mapping 160 Setting Basic Network Information Configuring Basic Network Information (CLI) This section provides information about the commands you use to configure basic network information on the Dell Networking N2000, N3000, and N4000 series switches. For more information about these commands, see the Dell Networking N2000, N3000, and N4000 Series Switches CLI Reference Guide at support.dell.com/manuals. Enabling the DHCP Client on the OOB Port NOTE: N2000 switches do not have an out-of-band interface. Beginning in Privileged EXEC mode, use the following commands to enable the DHCP client on the OOB port. Command Purpose configure Enter Global Configuration mode. interface out-of-band Enter Interface Configuration mode for the OOB port. ip address dhcp Enable the DHCP client. CTRL + Z Exit to Privileged EXEC mode. show ip interface out-of- Display network information for the OOB port. band Enabling the DHCP Client on the Default VLAN Beginning in Privileged EXEC mode, use the following commands to enable the DHCP client on the default VLAN, which is VLAN 1. As a best practice, it is recommended that a separate VLAN other than one used for client traffic be used for in-band management of the switch. In general, using VLAN 1, or any other VLAN carrying client traffic, for in-band management introduces a security vulnerability. Command Purpose configure Enter Global Configuration mode. interface vlan 1 Enter Interface Configuration mode for VLAN 1. ip address dhcp Enable the DHCP client. ipv6 address dhcp Enable the DHCPv6 client. Setting Basic Network Information 161 Command Purpose CTRL + Z Exit to Privileged EXEC mode. show ip interface vlan 1 Display network information for VLAN 1. Managing DHCP Leases Beginning in Privileged EXEC mode, use the following commands to manage and troubleshoot DHCP leases on the switch. Command Purpose show dhcp lease interface [interface] Display IPv4 addresses leased from a DHCP server. show ipv6 dhcp interface Display information about the IPv6 DHCP information vlan [interface] for all interfaces or for the specified interface. debug dhcp packet Display debug information about DHCPv4 client activities and to trace DHCPv4 packets to and from the local DHCPv4 client. debug ipv6 dhcp Display debug information about DHCPv6 client activities and to trace DHCPv6 packets to and from the local DHCPv6 client. ipv6 address {[prefix/prefixlien] | autoconfig | dhcp} Set the IPv6 address of the management interface or enables autoconfiguration or DHCP. ipv6 gateway ipv6- Set the IPv6 default gateway address. ipv6 enable Enable IPv6 functionality on the interface. address show ipv6 interface out- Show settings for the interface. of-band 162 Setting Basic Network Information Configuring Static Network Information on the OOB Port NOTE: N2000 switches do not have an out-of-band interface. Beginning in Privileged EXEC mode, use the following commands to configure a static IP address, subnet mask, and default gateway on the OOB port. If no default gateway is configured, then the zero subnet (0.0.0.0) is used. In this configuration, the OOB port can reach hosts in the local subnet only, because the OOB port will not be able to issue ARP requests to the default gateway. Configuring a default gateway address on the OOB port allows the OOB port to issue ARPs and address traffic to hosts on other subnets. The OOB port subnet may not overlap with any in-band VLAN subnet. Command Purpose configure Enter Global Configuration mode. interface out-of-band Enter Interface Configuration mode for the OOB port. ip address ip_address subnet_mask [gateway_ip] Configure a static IP address and subnet mask. Optionally, you can also configure a default gateway. ipv6 address prefix/prefix- Configure an IPv6 prefix for the OOB port ipv6 address enable Enable IPv6 addressing on the OOB port ipv6 address autoconfig Enable IPv6 auto-configuration for the OOB port ipv6 address dhcp Enable DHCP address assignment for the OOB port. CTRL + Z Exit to Privileged EXEC mode. length show ip interface out-of-band Verify the network information for the OOB port. NOTE: The out-of-band port also supports IPv6 address assignment, including IPv6 auto-configuration and an IPv6 DHCP client. Configuring Static Network Information on the Default VLAN Beginning in Privileged EXEC mode, use the following commands to configure a static IP address, subnet mask, and default gateway on the default VLAN. Alternatively, a DHCP server may be used to obtain a network address. The switch also supports IPv6 address auto-configuration. Setting Basic Network Information 163 Static IP subnets on inband ports (configured on switch VLANs) may not overlap with the OOB port subnet. If configuring management access on the front-panel ports, it is recomended that: • A VLAN other than the default VLAN be used to avoid attack vectors enabled by incorrect cabling. • Both ACLs and Management ACLs be utilized to reduce the possibility of DoS attacks or intruders gaining access to the switch management console. The advantage of the management ACL is that it can also protect the OOB port, whereas ACLs can only protect access via an in-band port. Command Purpose configure Enter Global Configuration mode. interface vlan 1 Enter Interface Configuration mode for VLAN 1. ip address ip_address subnet_mask Enter the IP address and subnet mask. ipv6 address prefix/prefix-length [eui64] Enter the IPv6 address and prefix. ipv6 enable Enable IPv6 on the interface. exit Exit to Global Configuration mode ip default-gateway ip_address Configure the default gateway.ipv6 gateway Configure the default gateway for IPv6. ipv6 gateway ip_address Configure the default gateway for IPv6. exit Exit to Privileged Exec mode. show ip interface vlan 1 Verify the network information for VLAN 1. show ipv6 interface vlan 1 Verify IPv6 network information for VLAN 1. Configuring and Viewing Additional Network Information Beginning in Privileged EXEC mode, use the following commands to configure a DNS server, the default domain name, and a static host name-toaddress entry. Use the show commands to verify configured information and to view dynamic host name mappings. 164 Setting Basic Network Information Command Purpose configure Enter Global Configuration mode. ip domain-lookup Enable IP DNS-based host name-to-address translation. ip name-server Enter the IP address of an available name server to use to resolve host names and IP addresses. ip_address You can specify up to six DNS servers. The first server you configure is the primary DNS server. ip domain-name name Define a default domain name to complete unqualified host names. ip host name ip_address Use to configure static host name-to-address mapping in the host cache. ip address-conflictdetect run Trigger the switch to run active address conflict detection by sending gratuitous ARP packets for IPv4 addresses on the switch. CTRL + Z Exit to Privileged EXEC mode. show ip interface vlan 1 Verify the network information for VLAN 1. show hosts Verify the configured network information and view the dynamic host mappings. show ip address-conflict View the status information corresponding to the last detected address conflict. clear ip address-conflict- Clear the address conflict detection status in the switch. detect Setting Basic Network Information 165 Basic Network Information Configuration Example In this example, an administrator at a Dell office in California decides not to use the Dell Easy Setup Wizard to perform the initial switch configuration. The administrator configures a Dell Networking N2000, N3000, and N4000 series switches to obtain its information from a DHCP server on the management network and creates the administrative user with read/write access. The administrator also configures the following information: • Primary DNS server: 10.27.138.20 • Secondary DNS server: 10.27.138.21 • Default domain name: sunny.dell.com The administrator also maps the administrative laptop host name to its IP address. The administrator uses the OOB port to manage the switch. To configure the switch: 1 Connect the OOB port to the management network. DHCP is enabled by on the switch OOB interface by default on N3000 and N4000 switches. DHCP is enabled on VLAN 1 on the N2000 switches. If the DHCP client on the switch has been disabled, use the following commands to enable the DHCP client on the OOB port. console#configure console(config)#interface out-of-band console(config-if)#ip address dhcp console(config-if)#exit 2 Configure the administrative user. console(config)#username admin password secret123 level 15 3 Configure the DNS servers, default domain name, and static host mapping. console(config)#ip name-server 10.27.138.20 10.27.138.21 console(config)#ip domain-name sunny.dell.com console(config)#ip host admin-laptop 10.27.65.103 console(config)#exit 166 Setting Basic Network Information 4 View the network information that the DHCP server on the network dynamically assigned to the switch. console#show ip interface out-of-band IP Address........................ 10.27.22.153 Subnet Mask...................... 255.255.255.0 Default Gateway.................. 10.27.22.1 Protocol Current................. DHCP Burned In MAC Address............ 001E.C9AA.AA08 5 View additional network information. console#show hosts Host name: Default domain: sunny.dell.com dell.com Name/address lookup is enabled Name servers (Preference order): 10.27.138.20, 10.27.138.21 Configured host name-to-address mapping: Host Addresses ----------- -----------------------------------admin-laptop 10.27.65.103 cache: TTL (Hours) Host Total Elapsed Type Addresses --------- ------- ------- --------- --------No hostname is mapped to an IP address 6 Verify that the static hostname is correctly mapped. console#ping admin-laptop Pinging admin-laptop with 0 bytes of data: Reply From 10.27.65.103: icmp_seq = 0. time <10 msec. Reply From 10.27.65.103: icmp_seq = 1. time <10 msec. Setting Basic Network Information 167 168 Setting Basic Network Information 8 Managing QSFP Ports QSFP ports available on N4000 series switches can operate in 1 x 40G mode or in 4 x 10G mode. Appropriate cables must be used that match the selected mode. When changing from one mode to another, a switch reboot is required. The QSFP ports also support stacking over the interfaces in either 1 x 40G or 4 x 10G mode. Changing from Ethernet mode to stacking mode and viceversa requires a reboot as well. The ports on a QSFP plugin module are named Fo1/1/1-2 in 40-gigabit mode and Te1/1/1-8 in 10-gigabit mode. On the N4064, the fixed QSFP ports are named Fo1/0/1-2 in 40-gigabit mode and Te1/0/49-56 in 10-gigabit mode. All of the possible populated or configured interfaces will show in the show interfaces status command regardless of the port mode, i.e. 40-gigabit or 10-gigabit. Unpopulated or unconfigured interfaces for plug in modules do not show in the show interfaces status command. The default setting for a 40-gigabit Ethernet interface is nonstacking, 40-gigabit Ethernet (1 x 40G). The commands to change 1 x 40G and 4 x 10G modes are always entered on the 40-gigabit interfaces. The commands to change the Ethernet/stack mode are entered on the appropriate interface (tengigabitethernet or fortygigabitethernet). It is possible to configure some of the 10G ports in a 40G interface as stacking and not others. To reconfigure a QSFP port, select the 40-gigabit port to change in Interface Config mode and enter the hardware profile portmode command with the selected mode. For example, to change a 1 x 40G port to 4 x 10G mode, enter the following commands on the forty-gigabit interface: console(config)#interface fo1/1/1 console(config-if-Fo1/1/2)#hardware profile portmode 4x10g This command will not take effect until the switch is rebooted. console(config-if-Fo1/1/2)#do reload Are you sure you want to reload the stack? (y/n) Managing QSFP Ports 169 To change a 4 x 10G port to 1 x 40G mode, enter the following commands on the 40-gigabit interface: console(config)#interface Fo2/1/1 console(config-if-Fo2/1/1)#hardware profile portmode 1x40g This command will not take effect until the switch is rebooted. console(config-if-Fo1/1/2)#do reload Are you sure you want to reload the stack? (y/n) Attempting to change the port mode on the tengigabit interface will give the error “An invalid interface has been used for this function.” 170 Managing QSFP Ports Managing a Switch Stack 9 This chapter describes how to configure and manage a stack of switches. The topics covered in this chapter include: • Stacking Overview • Default Stacking Values • Managing and Monitoring the Stack (Web) • Managing the Stack (CLI) • Stacking and NSF Usage Scenarios Stacking Overview The Dell Networking N2000, N3000, and N4000 and series switches include a stacking feature that allows up to 12 switches to operate as a single unit. The N2000 and N3000 series switches have two fixed mini-SAS stacking connectors at the rear. N2000 series switches will stack with other N2000 series switches and Dell Networking 3000 series switches stack with other 3000 series switches. Dell Networking 4000 series switches stack with other Dell Networking 4000 series switches over front panel ports configured for stacking. A stack of twelve 48-port N2000 or N3000 switches has an aggregate throughput capacity of 576 Gigabits. Dell Networking N2000/N3000 stacking links operate at 21 Gbps or 4.3% of total aggregate throughput capacity of a full stack; therefore, it is recommended that operators provision large stacking topologies such that it is unlikely that a significant portion of the stack capacity will transit stacking links. One technique for achieving this is to distribute uplinks evenly across the stack vs. connecting all uplinks to a single stack unit or to adjacent stacking units. Dell Networking N4000 series switches support high performance stacking over front panel ports, allowing increased capacity to be added as needed, without affecting network performance and providing a single point of management. Up to twelve Dell Networking N4000 series switches can be Managing a Switch Stack 171 stacked using any port as long as the link bandwidth for parallel stacking links is the same. In other words, all the port types on the N4000 series switches can be used for stacking. Additional stacking connections can be made between adjacent switch units to increase the stacking bandwidth provided that all redundant stacking links have the same port speed. It is strongly recommended that the stacking bandwidth be kept equal across all stacking connections; that is, avoid mixing single and double stacking connections within a stack. Up to eight redundant stacking links operating at the same speed can be configured on an N4000 stack unit (four in each direction). A stack of twelve N4000 series switches has an aggregate front panel capacity of 5.760 terabits (not including the 40G ports). Provisioning for 5% interstack capacity requires 280 gigabits of bandwidth dedicated to stacking or all four 40G ports plus another twelve 10G ports. Therefore, it is recommended that operators provision large stacking topologies such that it is unlikely that a significant portion of the stack capacity will transit stacking links. One technique for achieving this is to distribute downlinks and transit links evenly across the stack vs. connecting all downlinks/transit links to a single stack unit or to adjacent stacking units. If Priority Flow Control (PFC) is enabled on any port in an N4000 series stack, stacking is supported at distances up to 100 meters on the stacking ports. If PFC is not enabled, stacking is supported up to the maximum distance supported by the transceiver on the stack links. Note that PFC cannot be enabled on stacking ports — the system handles the buffering and flow control automatically. A single switch in the stack manages all the units in the stack (the stack master), and you manage the stack by using a single IP address. The IP address of the stack does not change, even if the stack master changes. A stack is created by daisy-chaining stacking links on adjacent units. If available, up to eight links per stack unit can be used for stacking (four in each direction). A stack of units is manageable as a single entity when the units are connected together. If a unit cannot detect a stacking partner on any port enabled for stacking, the unit automatically operates as a standalone unit. If a stacking partner is detected, the switch always operates in stacking mode. One unit in the stack is designated as the stack master. The master manages all the units in the stack. The stack master runs the user interface 172 Managing a Switch Stack and switch software, and propagates changes to the member units. To manage a stack using the serial interface, you must connect to the stack master via the connect command or by physically connecting the cable to the stack master. A second switch is designated as the standby unit, which becomes the master if the stack master is unavailable. You can manually configure which unit is selected as the standby, or the system can select the standby automatically. When units are in a stack, the following activities occur: • All units are checked for software version consistency. • The switch Control Plane is active only on the master. The Control Plane is a software layer that manages system and hardware configuration and runs the network control protocols to set system configuration and state. • The switch Data Plane is active on all units in the stack, including the master. The Data Plane is the set of hardware components that forward data packets without intervention from a control CPU. • The running configuration is propagated to all units and the application state is synchronized between the master and standby during normal stacking operation. The startup configuration and backup configuration on the stack members are not overwritten with the master switch configuration. Dell strongly recommends connecting the stack in a ring topology so that each switch is connected to two other switches. Connecting switches in a ring topology allows the stack to utilize the redundant communication path to each switch. If a switch in a ring topology fails, the stack can automatically establish a new communications path to the other switches. Switches not stacked in a ring topology may split into multiple independent stacks upon the failure of a single switch or stacking link. Additional stacking connections can be made between adjacent switch units to increase the stacking bandwidth, provided that all redundant stacking links have the same bandwidth. It is strongly recommended that the stacking bandwidth be kept equal across of all stacking connections; that is, avoid mixing single and double stacking connections within a stack. Up to eight redundant stacking links can be configured on a stacking unit (four in each direction). Figure 9-1 shows a stack with three switches as stack members connected in a ring topology. Managing a Switch Stack 173 Figure 9-1. Connecting a Stack of Switches Unit 1 Unit 2 Unit 3 The stack in Figure 9-1 has the following physical connections between the switches: • The lower stacking port on Unit 1 is connected to the upper stacking port on Unit 2. • The lower stacking port on Unit 2 is connected to the upper stacking port on Unit 3. • The lower stacing port on Unit 3 is connected to the upper stacking port on Unit 1. Dell Networking N2000, N3000, and N4000 Stacking Compatibility Dell Networking N2000, N3000, and N4000 series switches do not stack with different Dell Networking series switches or Dell PowerConnect series switches. Dell Networking N2000 series switches only stack with other N2000 174 Managing a Switch Stack series switches. Likewise, Dell Networking N3000 series switches only stack with other Dell N3000 series switches. Dell Networking N4000 series switches stack with other Dell Networking N4000 series switches. How is the Stack Master Selected? A stack master is elected or re-elected based on the following considerations, in order: 1 The switch is currently the stack master. 2 The switch has the higher MAC address. 3 A unit is selected as standby by the administrator, and a fail over action is manually initiated or occurs due to stack master failure. In most cases, a switch that is added to an existing stack will become a stack member, and not the stack master. When you add a switch to the stack, one of the following scenarios takes place regarding the management status of the new switch: • If the switch has the stack master function enabled but another stack master is already active, then the switch changes its configured stack master value to disabled. • If the stack master function is unassigned and there is another stack master in the system then the switch changes its configured stack master value to disabled. • If the stack master function is enabled or unassigned and there is no other stack master in the system, then the switch becomes stack master. • If the stack master function is disabled, the unit remains a non-stack master. If the entire stack is powered OFF and ON again, the unit that was the stack master before the reboot will remain the stack master after the stack resumes operation. You can manually set the unit number for the switch. To avoid unit-number conflicts, one of the following scenarios takes place when you add a new member to the stack: • If the switch has a unit number that is already in use, then the unit that you add to the stack changes its configured unit number to the lowest unassigned unit number. Managing a Switch Stack 175 • If the switch you add does not have an assigned unit number, then the switch sets its configured unit number to the lowest unassigned unit number. • If the unit number is configured and there are no other devices using the unit number, then the switch starts using the configured unit number. • If the switch detects that the maximum number of units already exist in the stack making it unable to assign a unit number, then the switch sets its unit number to unassigned and does not participate in the stack. Adding a Switch to the Stack When adding a new member to a stack, make sure that only the stack cables, and no network cables, are connected before powering up the new unit. Stack port configuration is stored on the member units. If stacking over Ethernet ports (N4000 only), configure the ports on the unit to be added to the stack as stacking ports and power the unit off prior to connecting the stacking cables. Make sure the links are not already connected to any ports of that unit. This is important because if STP is enabled and any links are UP, the STP reconvergence will take place as soon as the link is detected. After the stack cables on the new member are connected to the stack, you can power up the new units, beginning with the unit directly attached to the currently powered-up unit. Always power up new stack units closest to an existing powered unit first. Do not connect a new member to the stack after it is powered up. Also, do not connect two functional, powered-up stacks together. Hot insertion of units into a stack is not supported. If a new switch is added to a stack of switches that are powered and running and already have an elected stack master, the newly added switch becomes a stack member rather than the stack master. Use the boot auto-copy-sw command on the stack master to enable automatic firmware upgrade of newly added switches. If a firmware mismatch is detected, the newly added switch does not fully join the stack and holds until it is upgraded to the same firmware version as the master switch. After firmware synchronization finishes, the running configuration of the newly added unit is overwritten with the stack master configuration. Stack port configuration is always stored on the local unit and may be updated with preconfiguration information from the stack master when the unit joins the stack. 176 Managing a Switch Stack You can preconfigure information about a stack member and its ports before you add it to the stack. The preconfiguration takes place on the stack master. If there is saved configuration information on the stack master for the newly added unit, the stack master applies the configuration to the new unit; otherwise, the stack master applies the default configuration to the new unit. Removing a Switch from the Stack Prior to removing a member from a stack, check that other members of the stack will not become isolated from the stack due to the removal. Check the stack-port error counters to ensure that a stack configured in a ring topology can establish a communication path around the member to be removed. The main point to remember when you remove a unit from the stack is to disconnect all the links on the stack member to be removed. Also, be sure to take the following actions: • Remove all the STP participating ports and wait to stabilize the STP. • Remove all the member ports of any Port-Channels (LAGs) so there will not be any control traffic destined to those ports connected to this member. • Statically re-route any traffic going through this unit. When a unit in the stack fails, the stack master removes the failed unit from the stack. The failed unit reboots with its original running-config. If the stack is configured in a ring topology, then the stack automatically routes around the failed unit. If the stack is not configured in a ring topology, then the stack may split, and the isolated members will reboot and re-elect a new stack master. No changes or configuration are applied to the other stack members; however, the dynamic protocols will try to reconverge as the topology could change because of the failed unit. If you remove a unit and plan to renumber the stack, issue a no member unit command in Stack Configuration mode to delete the removed switch from the configured stack member information. How is the Firmware Updated on the Stack? When you add a new switch to a stack, the Stack Firmware Synchronization feature automatically synchronizes the firmware version with the version running on the stack master per the configuration on the master switch. The synchronization operation may result in either upgrade or downgrade of firmware on the mismatched stack member. Managing a Switch Stack 177 Upgrading the firmware on a stack of switches is the same as upgrading the firmware on a single switch. After you download a new image by using the File Download page or copy command, the downloaded image is distributed to all the connected units of the stack. For more information about downloading and installing images, see "Managing Images and Files" on page 359. What is Stacking Standby? A standby unit is preconfigured in the stack. If the current stack master fails, the standby unit becomes the stack master. If no switch is pre-configured as the standby unit, the software automatically selects a standby unit from the existing stack units. When the failed master resumes normal operation, it joins the stack as a member (not a master) if the new stack master has already been elected. The stack master copies its running configuration to the standby unit whenever it changes (subject to some restrictions to reduce overhead). This enables the standby unit to take over the stack operation with minimal interruption if the stack master becomes unavailable. Operational state synchronization also occurs: • when you save the running configuration to the startup configuration on the stack master. • when the backup unit changes. What is Nonstop Forwarding? Networking devices, such as the Dell Networking series switches, are often described in terms of three semi-independent functions called the forwarding plane, the control plane, and the management plane. The forwarding plane forwards data packets and is implemented in hardware. The control plane is the set of protocols that determine how the forwarding plane should forward packets, deciding which data packets are allowed to be forwarded and where they should go. Application software on the stack master acts as the control plane. The management plane is application software running on the stack master that provides interfaces allowing a network administrator to configure the device. The Nonstop Forwarding (NSF) feature allows the forwarding plane of stack units to continue to forward packets while the control and management planes restart as a result of a power failure, hardware failure, or software fault 178 Managing a Switch Stack on the stack master. This type of operation is called nonstop forwarding. When the stack master fails, only the switch ASICs on the stack master need to be restarted. To prevent adjacent networking devices from rerouting traffic around the restarting device, the NSF feature uses the following three techniques: 1 A protocol can distribute a part of its control plane to stack units so that the protocol can give the appearance that it is still functional during the restart. 2 A protocol may enlist the cooperation of its neighbors through a technique known as graceful restart. 3 A protocol may simply restart after the failover if neighbors react slowly enough that they will not normally detect the outage. The NSF feature enables the stack master unit to synchronize the runningconfig within 60 seconds after a configuration change has been made. However, if a lot of configuration changes happen concurrently, NSF uses a back-off mechanism to reduce the load on the switch. The show nsf command output includes information about when the next running-config synchronization will occur. Initiating a Failover The NSF feature allows you to initiate a failover using the initiate failover command, which causes the former stack master to reboot (cold start), and the new master to perform a warm restart. Initiating a failover reloads the stack master, triggering the backup unit to take over. Before the failover, the stack master pushes application data and other important information to the backup unit. Although the handoff is controlled and causes minimal network disruption, some application state is lost, such as pending timers and other pending internal events. Checkpointing Switch applications (features) that build up a list of data such as neighbors or clients can significantly improve their restart behavior by remembering this data across a warm restart. This data can either be stored persistently, as DHCP server and DHCP snooping store their bindings database, or the stack master can checkpoint this data directly to the standby unit. Persistent Managing a Switch Stack 179 storage allows an application on a standalone unit to retain its data across a restart, but since the amount of storage is limited, persistent storage is not always practical. The NSF checkpoint service allows the stack master to communicate certain data to the backup unit in the stack. When the stack selects a backup unit, the checkpoint service notifies applications to start a complete checkpoint. After the initial checkpoint is done, applications checkpoint changes to their data. NOTE: The switch cannot guarantee that a backup unit has exactly the same data that the stack master has when it fails. For example, the stack master might fail before the checkpoint service gets data to the backup if an event occurs shortly before a failover. Table 9-1 lists the applications on the switch that checkpoint data and describes the type of data that is checkpointed. Table 9-1. Applications that Checkpoint Data Application Checkpointed Data ARP Dynamic ARP entries Auto VOIP Calls in progress Captive Portal Authenticated clients DHCP server Address bindings (persistent) DHCP snooping DHCP bindings database DOT1Q Internal VLAN assignments DOT1S Spanning tree port roles, port states, root bridge, etc. DOT1X Authenticated clients DOT3ad Port states IGMP/MLD Snooping Multicast groups, list of router ports, last query data for each VLAN IPv6 NDP Neighbor cache entries iSCSI Connections LLDP List of interfaces with MED devices attached 180 Managing a Switch Stack Table 9-1. Applications that Checkpoint Data Application Checkpointed Data OSPFv2 Neighbors and designated routers OSPFv3 Neighbors and designated routers Route Table Manager IPv4 and IPv6 dynamic routes SIM The system's MAC addresses. System up time. IP address, network mask, default gateway on each management interface, DHCPv6 acquired IPv6 address. Voice VLAN VoIP phones identified by CDP or DHCP (not LLDP) Switch Stack MAC Addressing and Stack Design Considerations The switch stack uses the MAC addresses assigned to the stack master. NOTE: Each switch is assigned four consecutive MAC addresses. A stack of switches uses the MAC addresses assigned to the stack master. If the backup unit assumes control due to a stack master failure or warm restart, the backup unit continues to use the original stack master’s MAC addresses. This reduces the amount of disruption to the network because ARP and other L2 entries in neighbor tables remain valid after the failover to the backup unit. Stack units should always be connected with a ring topology (or other biconnected topology), so that the loss of a single stack link does not divide the stack into multiple stacks. If a stack is partitioned such that some units lose all connectivity to other units, then both parts of the stack start using the same MAC addresses. This can cause severe problems in the network. If you move the stack master to a different place in the network, make sure you power down the whole stack before you redeploy the stack master so that the stack members do not continue to use the MAC address of the redeployed switch. NSF Network Design Considerations You can design your network to take maximum advantage of NSF. For example, by distributing a LAG's member ports across multiple units, the stack can quickly switch traffic from a port on a failed unit to a port on a Managing a Switch Stack 181 surviving unit. When a unit fails, the forwarding plane of surviving units removes LAG members on the failed unit so that it only forwards traffic onto LAG members that remain up. If a LAG is left with no active members, the LAG goes down. To prevent a LAG from going down, configure LAGs with members on multiple units within the stack, when possible. If a stack unit fails, the system can continue to forward on the remaining members of the stack. If your switch stack performs VLAN routing, another way to take advantage of NSF is to configure multiple “best paths” to the same destination on different stack members. If a unit fails, the forwarding plane removes Equal Cost Multipath (ECMP) next hops on the failed unit from all unicast forwarding table entries. If the cleanup leaves a route without any next hops, the route is deleted. The forwarding plane only selects ECMP next hops on surviving units. For this reason, try to distribute links providing ECMP paths across multiple stack units. Why is Stacking Needed? Stacking increases port count without requiring additional configuration. If you have multiple Dell Networking switches, stacking them helps make management of the switches easier because you configure the stack as a single unit and do not need to configure individual switches. Default Stacking Values Stacking is always enabled on Dell Networking series switches. On the N4000 switches, by default, the 10G SFP+ ports are in Ethernet mode and must be configured to be used as stacking ports. Ports that are configured in stacking mode show as “detached” in the output of the show interfaces status command. Configuring an Ethernet port as a stacking port changes the default configuration of the port. The port stacking configuration does not show in the running-config. To determine the stacking configuration of a port, use the show switch stack-ports command. On the N2000/N3000 switches, there are 182 Managing a Switch Stack two fixed stacking ports in the rear of the switch. Stacking on Ethernet ports is not supported. The fixed stacking ports show as TwentygigabitStacking and are abbreviated Tw. NSF is enabled by default. You can disable NSF to redirect the CPU resources consumed by data checkpointing. Checkpointing only occurs when a backup unit is elected, so there is no need to disable the NSF feature on a standalone switch. When a new unit is added to the stack, the new unit takes the configuration of the stack, including the NSF setting. OSPF implements a separate graceful restart control that enables NSF for OSPF. OSPF graceful restart is not enabled by default. Managing a Switch Stack 183 Managing and Monitoring the Stack (Web) This section provides information about the OpenManage Switch Administrator pages for configuring and monitoring stacking on a Dell Networking N2000, N3000, and N4000 series switches. For details about the fields on a page, click at the top of the page. NOTE: The changes you make to the Stacking configuration pages take effect only after the device is reset. Unit Configuration Use the Unit Configuration page to change the unit number and unit type (Management, Member, or Standby). To display the Unit Configuration page, click System → Stack Management → Unit Configuration in the navigation panel. Figure 9-2. Stack Unit Configuration 184 Managing a Switch Stack Changing the ID or Switch Type for a Stack Member To change the switch ID or type: 1 Open the Unit Configuration page. 2 Click Add to display the Add Unit page. Figure 9-3. Add Remote Log Server Settings 3 Specify the switch ID, and select the model number of the switch. 4 Click Apply. Stack Summary Use the Stack Summary page to view a summary of switches participating in the stack. To display the Stack Summary page, click System → Stack Management → Stack Summary in the navigation panel. Figure 9-4. Stack Summary Managing a Switch Stack 185 Stack Firmware Synchronization Use the Stack Firmware Synchronization page to control whether the firmware image on a new stack member can be automatically upgraded or downgraded to match the firmware image of the stack master. To display the Stack Firmware Synchronization page, click System → Stack Management → Stack Firmware Synchronization in the navigation panel. Figure 9-5. Stack Firmware Synchronization 186 Managing a Switch Stack Supported Switches Use the Supported Switches page to view information regarding each type of supported switch for stacking, and information regarding the supported switches. To display the Supported Switches page, click System → Stack Management → Supported Switches in the navigation panel. Figure 9-6. Supported Switches Managing a Switch Stack 187 Stack Port Summary Use the Stack Port Summary page to configure the stack-port mode and to view information about the stackable ports. This screen displays the unit, the stackable interface, the configured mode of the interface, the running mode as well as the link status and link speed of the stackable port. NOTE: By default the ports are configured to operate as Ethernet ports. To configure a port as a stack port, you must change the Configured Stack Mode setting from Ethernet to Stack. To display the Stack Port Summary page, click System → Stack Management → Stack Port Summary in the navigation panel. Figure 9-7. Stack Port Summary 188 Managing a Switch Stack Stack Port Counters Use the Stack Port Counters page to view the transmitted and received statistics, including data rate and error rate. To display the Stack Port Counters page, click System → Stack Management → Stack Point Counters in the navigation panel. Figure 9-8. Stack Port Counters Stack Port Diagnostics The Stack Port Diagnostics page is intended for Field Application Engineers (FAEs) and developers only. Managing a Switch Stack 189 NSF Summary Use the NSF Summary page to change the administrative status of the NSF feature and to view NSF information. NOTE: The OSPF feature uses NSF to enable the hardware to continue forwarding IPv4 packets using OSPF routes while a backup unit takes over stack master responsibility. To configure NSF on a stack that uses OSPF or OSPFv3, see "NSF OSPF Configuration" on page 1137 and "NSF OSPFv3 Configuration" on page 1154. To display the NSF Summary page, click System → Stack Management → NSF Summary in the navigation panel. Figure 9-9. NSF Summary To cause the maser unit to failover to the standby unit, click Initiate Failover. The failover results in a warm restart of the stack master. Initiating a failover reloads the stack master, triggering the backup unit to take over. 190 Managing a Switch Stack Checkpoint Statistics Use the Checkpoint Statistics page to view information about checkpoint messages generated by the stack master. To display the Checkpoint Statistics page, click System → Stack Management → Checkpoint Statistics in the navigation panel. Figure 9-10. Checkpoint Statistics Managing a Switch Stack 191 Managing the Stack (CLI) This section provides information about the commands you use to manage the stack and view information about the switch stack. For more information about these commands, see the Dell Networking N2000, N3000, and N4000 Series Switches CLI Reference Guide at support.dell.com/manuals. Configuring Stack Member, Stack Port, and NSF Settings Beginning in Privileged EXEC mode, use the following commands to configure stacking and NSF settings. Command Purpose configure Enter Global Configuration mode. switch current_ID renumber new_ID Change the switch ID number. The valid range is 1-10. NOTE: Changing the ID number causes all switches in the stack to be reset to perform stack master renumbering. The running configuration is cleared when the units reset. stack Enter Global Stack Configuration mode. initiate failover Move the management switch functionality from the master switch to the standby switch. standby unit Specify the stack member that will come up as the master if a stack failover occurs. set description unit Configure a description for the specified stack member. 192 Managing a Switch Stack Command Purpose member unit SID Add a switch to the stack and specify the model of the new stack member. • unit - The switch unit ID • SID - The index into the database of the supported switch types, indicating the type of the switch being preconfigured. Note: Member configuration displayed in the running config may be learned from the physical stack. Member configuration is not automatically saved in the startupconfig. Save the configuration to retain the current member settings. To view the SID associated with the supported switch types, use the show supported switchtype command in Privileged EXEC mode. stack-port Set the mode of the port to either Ethernet or stacking tengigabitethernet (N4000 only). unit/slot/port {ethernet | stack} nsf Enable nonstop forwarding on the stack. exit Exit to Global Config mode. boot auto-copy-sw Enable the Stack Firmware Synchronization feature. boot auto-copy-sw allow- Allow the firmware version on the newly added stack downgrade member to be downgraded if the firmware version on manager is older. Config migration is not assured for firmware downgrade. exit Exit to Privileged EXEC mode. show auto-copy-sw View the Stack Firmware Synchronization settings for the stack. reload unit If necessary, reload the specified stack member. NOTE: The OSPF feature uses NSF to enable the hardware to continue forwarding IPv4 packets using OSPF routes while a backup unit takes over stack master responsibility. Additional NSF commands are available in OSPF and OSPFv3 command modes. For more information, see "NSF OSPF Configuration" on page 1137 and "NSF OSPFv3 Configuration" on page 1154 Managing a Switch Stack 193 Viewing and Clearing Stacking and NSF Information Beginning in Privileged EXEC mode, use the following commands to view stacking information and to clear NSF statistics. Command Purpose show switch [stack- member-number] View information about all stack members or the specified member. show switch stackstandby View the ID of the switch that will assume the role of the stack master if it goes down. show switch stack-ports View information about the stacking ports. show switch stack-ports counters View the statistics about the data the stacking ports have transmitted and received. show switch stack-ports stack-path View the path that packets take from one stack member to another. show supported switchtype View the Dell Networking models that are supported in the stack and the switch index (SID) associated with each model. show nsf View summary information about the NSF feature. show checkpoint statistics View information about checkpoint messages generated by the stack master. clear checkpoint statistics Reset the checkpoint statistics counters to zero. 194 Managing a Switch Stack Stacking and NSF Usage Scenarios Only a few settings are available to control the stacking configuration, such as the designation of the standby unit or enabling/disabling NSF. The examples in this section describe how the stacking and NSF feature act in various environments. This section contains the following examples: • Basic Failover • Preconfiguring a Stack Member • NSF in the Data Center • NSF and VoIP • NSF and DHCP Snooping • NSF and the Storage Access Network • NSF and Routed Access Basic Failover In this example, the stack has four members that are connected in a ring topology, as Figure 9-11 shows. Figure 9-11. Basic Stack Failover Managing a Switch Stack 195 When all four units are up and running, the show switch CLI command gives the following output: console#show switch SW Management Status Standby Status --1 2 3 4 --------Stack Member Stack Member Mgmt Switch Stack Member ------- Preconfig PluggedModel ID in Model ID -------- --------N3048 N3048 N3048 N3048 N3048 N3048 N3048 N3048 Switch Code Status Version ------- -------OK 6.0.0.0 OK 6.0.0.0 OK 6.0.0.0 OK 6.0.0.0 At this point, if Unit 2 is powered off or rebooted due to an unexpected failure, show switch gives the following output: console#show switch SW Management Status Standby Preconfig Plugged- Switch Status Model ID in Model Status ID --- --------------- -------- ------------------1 Stack Member N3048 N3048 OK 2 Unassigned N3048 Not Present 3 Mgmt Switch N3048 N3048 OK 4 Stack Member N3048 N3048 OK Code Version -------6.0.0.0 0.0.0.0 6.0.0.0 6.0.0.0 When the failed unit resumes normal operation, the previous configuration that exists for that unit is reapplied by the stack master. To permanently remove the unit from the stack, enter into Stack Config Mode and use the member command, as the following example shows. console#configure console(config)#stack console(config-stack)#no member 2 console(config-stack)#exit console(config)#exit console#show switch 196 Managing a Switch Stack SW Management Status Standby Preconfig Plugged- Switch Status Model ID in Model Status ID --- --------------- -------- ------------------1 Stack Member N3048 N3048 OK 3 Mgmt Switch N3048 N3048 OK 4 Stack Member N3048 N3048 OK Code Version -------6.0.0.0 6.0.0.0 6.0.0.0 Preconfiguring a Stack Member To preconfigure a stack member before connecting the physical unit to the stack, use the show support switchtype command to obtain the SID of the unit to be added. The example in this section demonstrates pre-configuring a Dell Networking switch on a stand-alone Dell Networking switch. To configure the switch: 1 View the list of SIDs to determine which SID identifies the switch to preconfigure. The following is the output on N3000 and N2000 series switches. console#show supported switchtype SID --1 2 3 4 5 6 7 8 9 Switch Model ID -------------------------------N3024 N3024F N3024P N3048 N3048P N2024 N2024P N2048 N2048P NOTE: N2000 and N3000 switches cannot be stacked together. Managing a Switch Stack 197 2 Preconfigure the switch (SID = 2) as member number 2 in the stack. console#configure console(config)#stack console(config-stack)#member 2 2 console(config-stack)#exit console(config)#exit 3 Confirm the stack configuration. Some of the fields have been omitted from the following output due to space limitations. console#show switch Management Standby SW Status Status --- ---------- --------1 Mgmt Sw 198 Preconfig Model ID ------------N3048 Managing a Switch Stack Plugged-in Model ID ------------N3048 Switch Status ------------OK Code Version ----------6.0.0.0 NSF in the Data Center Figure 9-12 illustrates a data center scenario, where the stack of two Dell Networking switches acts as an access switch. The access switch is connected to two aggregation switches, AS1 and AS2. The stack has a link from two different units to each aggregation switch, with each pair of links grouped together in a LAG. The two LAGs and link between AS1 and AS2 are members of the same VLAN. Spanning tree is enabled on the VLAN. Assume spanning tree selects AS1 as the root bridge. Assume the LAG to AS1 is the root port on the stack and the LAG to AS2 is discarding. Unit 1 is the stack master. If unit 1 fails, the stack removes the Unit 1 link to AS1 from its LAG. The stack forwards outgoing packets through the Unit 2 link to AS1 during the failover. During the failover, the stack continues to send BPDUs and LAG PDUs on its links on Unit 2. The LAGs stay up (with one remaining link in each), and spanning tree on the aggregation switches does not see a topology change. Figure 9-12. Data Center Stack Topology Managing a Switch Stack 199 NSF and VoIP Figure 9-13 shows how NSF maintains existing voice calls during a stack master failure. Assume the top unit is the stack master. When the stack master fails, the call from phone A is immediately disconnected. The call from phone B continues. On the uplink, the forwarding plane removes the failed LAG member and continues using the remaining LAG member. If phone B has learned VLAN or priority parameters through LLDP-MED, it continues to use those parameters. The stack resumes sending LLDPDUs with MED TLVs once the control plane restarts. Phone B may miss an LLDPDU from the stack, but should not miss enough PDUs to revert its VLAN or priority, assuming the administrator has not reduced the LLDPDU interval or hold count. If phone B is receiving quality of service from policies installed in the hardware, those policies are retained across the stack master restart. Figure 9-13. NSF and VoIP 200 Managing a Switch Stack NSF and DHCP Snooping Figure 9-14 illustrates an L2 access switch running DHCP snooping. DHCP snooping only accepts DHCP server messages on ports configured as trusted ports. DHCP snooping listens to DHCP messages to build a bindings database that lists the IP address the DHCP server has assigned to each host. IP Source Guard (IPSG) uses the bindings database to filter data traffic in hardware based on source IP address and source MAC address. Dynamic ARP Inspection (DAI) uses the bindings database to verify that ARP messages contain a valid sender IP address and sender MAC address. DHCP snooping checkpoints its bindings database. Figure 9-14. NSF and DHCP Snooping If the stack master fails, all hosts connected to that unit lose network access until that unit reboots. The hardware on surviving units continues to enforce source filters IPSG installed prior to the failover. Valid hosts continue to communicate normally. During the failover, the hardware continues to drop data packets from unauthorized hosts so that security is not compromised. Managing a Switch Stack 201 If a host is in the middle of an exchange with the DHCP server when the failover occurs, the exchange is interrupted while the control plane restarts. When DHCP snooping is enabled, the hardware traps all DHCP packets to the CPU. The control plane drops these packets during the restart. The DHCP client and server retransmit their DHCP messages until the control plane has resumed operation and messages get through. Thus, DHCP snooping does not miss any new bindings during a failover. As DHCP snooping applies its checkpointed DHCP bindings, IPSG confirms the existence of the bindings with the hardware by reinstalling its source IP address filters. If Dynamic ARP Inspection is enabled on the access switch, the hardware traps ARP packets to the CPU on untrusted ports. During a restart, the control plane drops ARP packets. Thus, new traffic sessions may be briefly delayed until after the control plane restarts. If IPSG is enabled and a DHCP binding is not checkpointed to the backup unit before the failover, that host will not be able to send data packets until it renews its IP address lease with the DHCP server. NSF and the Storage Access Network Figure 9-15 illustrates a stack of three Dell Networking switches connecting two servers (iSCSI initiators) to a disk array (iSCSI targets). There are two iSCSI connections as follows: Session A: 10.1.1.10 to 10.1.1.3 Session B: 10.1.1.11 to 10.1.1.1 An iSCSI application running on the stack master (the top unit in the diagram) has installed priority filters to ensure that iSCSI traffic that is part of these two sessions receives priority treatment when forwarded in hardware. 202 Managing a Switch Stack Figure 9-15. NSF and a Storage Area Network When the stack master fails, session A drops. The initiator at 10.1.1.10 detects a link down on its primary NIC and attempts to reestablish the session on its backup NIC to a different IP address on the disk array. The hardware forwards the packets to establish this new session, but assuming the session is established before the control plane is restarted on the backup unit, the new session receives no priority treatment in the hardware. Session B remains established and fully functional throughout the restart and continues to receive priority treatment in the hardware. Managing a Switch Stack 203 NSF and Routed Access Figure 9-16 shows a stack of three units serving as an access router for a set of hosts. Two LAGs connect the stack to two aggregation routers. Each LAG is a member of a VLAN routing interface. The stack has OSPF and PIM adjacencies with each of the aggregation routers. The top unit in the stack is the stack master. Figure 9-16. NSF and Routed Access If the stack master fails, its link to the aggregation router is removed from the LAG. When the control plane restarts, both routing interfaces come back up by virtue of the LAGs coming up. OSPF sends grace LSAs to inform its OSPF neighbors (the aggregation routers) that it is going through a graceful restart. NOTE: The graceful restart feature for OSPF is disabled by default. For information about the web pages and commands to configure NSF for OSPF or OSPFv3, see "Configuring OSPF and OSPFv3" on page 1111. The grace LSAs reach the neighbors before they drop their adjacencies with the access router. PIM starts sending hello messages to its neighbors on the aggregation routers using a new generation ID to prompt the neighbors to quickly resend multicast routing information. PIM neighbors recognize the new generation ID and immediately relay the group state back to the restarting router. IGMP sends queries to relearn the hosts' interest in multicast groups. IGMP tells PIM the group membership, and PIM sends 204 Managing a Switch Stack JOIN messages upstream. The control plane updates the driver with checkpointed unicast routes. The forwarding plane reconciles L3 hardware tables. The OSPF graceful restart finishes, and the control plane deletes any stale unicast routes not relearned at this point. The forwarding plane reconciles L3 multicast hardware tables. Throughout the process, the hosts continue to receive their multicast streams, possibly with a short interruption as the top aggregation router learns that one of its LAG members is down. The hosts see no more than a 50 ms interruption in unicast connectivity. Managing a Switch Stack 205 206 Managing a Switch Stack 10 Configuring Authentication, Authorization, and Accounting This chapter describes how to control access to the switch management interface using authentication and authorization. It also describes how to record this access using accounting. Together the three services are referred to by the acronym AAA. The topics covered in this chapter include: • AAA Overview • Authentication • Authorization • Accounting • Authentication Examples • Authorization Examples • Using RADIUS Servers to Control Management Access • Using TACACS+ Servers to Control Management Access • Default Configurations AAA Overview AAA is a framework for configuring management security in a consistent way. Three services make up AAA: • Authentication—Validates the user identity. Authentication takes place before the user is allowed access to switch services. • Authorization—Determines which services the user is allowed to access. • Accounting—Collects and sends security information about users and commands. Configuring Authentication, Authorization, and Accounting Each service is configured using method lists. The method lists define how each service is to be performed by specifying the methods available to perform a service. The first method in a list is tried first. If the first method returns an error, the next method in the list is tried. This continues until all methods in the list have been attempted. If no method can perform the service, then the service fails. A method may return an error due to lack of network access, misconfiguration of a server, and other reasons. If there is no error, the method returns success if the user is allowed access to the service and failure if the user is not. AAA gives the user flexibility in configuration by allowing different method lists to be assigned to different access lines. In this way, it is possible to configure different security requirements for the serial console than for Telnet, for example. Methods A method performs the configured service. Not every method is available for every service. Some methods require a username and password and other methods only require a password. Table 10-1 summarizes the various methods: Table 10-1. AAA Methods Method Username? Password? Can Return an Error? enable no yes yes ias yes yes no line no yes yes local yes yes yes none no no no radius yes yes yes tacacs yes yes yes 208 Configuring Authentication, Authorization, and Accounting Methods that never return an error cannot be followed by any other methods in a method list. • The enable method uses the enable password. If there is no enable password defined, then the enable method will return an error. • The ias method is a special method that is only used for 802.1X. It uses an internal database (separate from the local user database) that acts like an 802.1X authentication server. This method never returns an error. It will always pass or deny a user. • The line method uses the password for the access line on which the user is accessing the switch. If there is no line password defined for the access line, then the line method will return an error. • The local method uses the local user database. If the user password does not match, then access is denied. This method returns an error if the user name is not present in the local user database. • The none method does not perform any service, but instead always returns a result as if the service had succeeded. This method never returns an error. If none is configured as a method, the user will always be authenticated and allowed to access the switch. • The radius and tacacs methods communicate with servers running the RADIUS and TACACS+ protocols, respectively. These methods can return an error if the switch is unable to contact the server. Access Lines There are five access lines: console, Telnet, SSH, HTTP, and HTTPS. HTTP and HTTPS are not configured using AAA method lists. Instead, the authentication list for HTTP and HTTPS is configured directly (authorization and accounting are not supported). The default method lists for both the HTTP and HTTPS access lines consist of only the local method. Each of the other access lines may be assigned method lists independently for the AAA services. The SSH line has built-in authentication beyond that configured by the administrator. In the SSH protocol itself, there are multiple methods for authentication. These are not the authentication methods configured in AAA, but are internal to SSH itself. When an SSH connection is attempted, the challengeresponse method is specified in the connection request. Configuring Authentication, Authorization, and Accounting 209 The methods available for authentication are: host-based authentication, public key authentication, challenge-response authentication, and password authentication. Authentication methods are tried in the order specified above, although SSH-2 has a configuration option to change the default order. Host-based authentication operates as follows: If the host from which the user logs in is listed in a specific file (/etc/hosts.equiv or /etc/ssh/shosts.equiv) on the remote host, and the user names are the same on both hosts, or if the files ~/.rhosts or ~/.shosts exist in the user's home directory on the remote host and contain a line containing the name of the client machine and the name of the user on that machine, the user is considered for login. Additionally, the server must be able to verify the client's host key for login to be permitted. This authentication method closes security holes due to IP spoofing, DNS spoofing, and routing spoofing. This authentication method is not implemented by DNOS. Public key authentication operates as follows: The administrator first generates a pair of encryption keys, the "public" key and the "private" key. Messages encrypted with the private key can only be decrypted by the public key, and vice-versa. The administrator keeps the private key on his/her local machine, and loads the public key on to the switch. When the administrator attempts to log into the switch, the protocol sends a brief message, encrypted with the public key. If the switch can decrypt the message (and can send back some proof that it has done so) then the response proves that switch must possess the private key, and user is authenticated without giving a username/password. This method is implemented in DNOS. If the user does not present a certificate, it is not considered an error, and authentication will continue with challenge-response authentication. Challenge-response authentication works as follows: The switch sends an arbitrary "challenge" text and prompts for a response. SSH-2 allows multiple challenges and responses; SSH-1 is restricted to one challenge/response only. Examples of challenge-response authentication include BSD Authentication. Finally, if all other authentication methods fail, SSH prompts the user for a password. 210 Configuring Authentication, Authorization, and Accounting Authentication Authentication is the process of validating a user's identity. During the authentication process, only identity validation is done. There is no determination made of which switch services the user is allowed to access. This is true even when RADIUS is used for authentication; RADIUS cannot perform separate transactions for authentication and authorization. However, the RADIUS server can provide attributes during the authentication process that are used in the authorization process. Authentication Types There are three types of authentication: • Login— Login authentication grants access to the switch if the user credentials are validated. Access is granted only at privilege level one. • Enable—Enable authentication grants access to a higher privilege level if the user credentials are validated for the higher privilege level. When RADIUS is used for enable authentication, the username for this request is always $enab15$. The username used to log into the switch is not used for RADIUS enable authentication. • Dot1x—Dot1x authentication is used to grant an 802.1X supplicant access to the network. For more information about 802.1X, see "Configuring Port and System Security" on page 503. Table 10-2 shows the valid methods for each type of authentication: Table 10-2. Valid Methods for Authentication Types Method Login Enable Dot1x enable yes yes no ias no no yes line yes yes no local yes no no none yes yes yes radius yes yes yes tacacs yes yes no Configuring Authentication, Authorization, and Accounting 211 Authorization Authorization is used to determine which services the user is allowed to access. For example, the authorization process may assign a user’s privilege level, which determines the set of commands the user can execute. There are three kinds of authorization: commands, exec, and network. • Commands: Command authorization determines which CLI commands the user is authorized to execute. • Exec: Exec authorization determines what the user is authorized to do on the switch; that is, the user’s privilege level and an administrative profile. • Network: Network authorization enables a RADIUS server to assign a particular 802.1X supplicant to a VLAN. For more information about 802.1X, see "Configuring Port and System Security" on page 503. Table 10-3 shows the valid methods for each type of authorization: Table 10-3. Authorization Methods Method Commands Exec Network local no yes no none yes yes no radius no yes yes tacacs yes yes no Exec Authorization Capabilities Dell Networking switches support two types of service configuration with exec authorization: privilege level and administrative profiles. Privilege Level By setting the privilege level during exec authorization, a user can be placed directly into Privileged EXEC mode when they log into the command line interface. 212 Configuring Authentication, Authorization, and Accounting Administrative Profiles The Administrative Profiles feature allows the network administrator to define a list of rules that control the CLI commands available to a user. These rules are collected in a “profile.” The rules in a profile can define the set of commands, or a command mode, to which a user is permitted or denied access. Within a profile, rule numbers determine the order in which the rules are applied. When a user enters a CLI command, rules within the first profile assigned to the user are applied in descending order until there is a rule that matches the input. If no rule permitting the command is found, then the other profiles assigned to the user (if any) are searched for rules permitting the command. Rules may use regular expressions for command matching. All profiles have an implicit “deny all” rule, such that any command that does not match any rule in the profile is considered to have been denied by that profile. A user can be assigned to more than one profile. If there are conflicting rules in profiles, the “permit” rule always takes precedence over the “deny” rule. That is, if any profile assigned to a user permits a command, then the user is permitted access to that command. A user may be assigned up to 16 profiles. A number of profiles are provided by default. These profiles cannot be altered by the switch administrator. See "Administrative Profiles" on page 240 for the list of default profiles. If the successful authorization method does not provide an administrative profile for a user, then the user is permitted access based upon the user's privilege level. This means that, if a user successfully passes enable authentication or if exec authorization assigns a privilege level, the user is permitted access to all commands. This is also true if none of the administrative profiles provided are configured on the switch. If some, but not all, of the profiles provided in the authentication are configured on the switch, then the user is assigned the profiles that exist, and a message is logged that indicates which profiles could not be assigned. Configuring Authentication, Authorization, and Accounting 213 Accounting Accounting is used to record security events, such as a user logging in or executing a command. Accounting records may be sent upon completion of an event (stop-only) or at both the beginning and end of an event (startstop). There are three types of accounting: commands, Dot1x, and exec. • Commands—Sends accounting records for command execution. • Dot1x—Sends accounting records for network access. • Exec—Sends accounting records for management access (logins). For more information about the data sent in accounting records, see "Which RADIUS Attributes Does the Switch Support?" on page 234 and "Using TACACS+ Servers to Control Management Access" on page 237. Table 10-4 shows the valid methods for each type of accounting: Table 10-4. Accounting Methods Method Commands Dot1x Exec radius no yes yes tacacs yes no yes 214 Configuring Authentication, Authorization, and Accounting Authentication Examples It is important to understand that during authentication, all that happens is that the user is validated. If any attributes are returned from the server, they are not processed during authentication. In the examples below, it is assumed that the default configuration of authorization—that is, no authorization—is used. Local Authentication Example Use the following configuration to require local authentication when logging in over a Telnet connection: aaa authentication login “loc” local line telnet login authentication loc exit enable password PaSSW0rd username guest password password passwords strength minimum numeric-characters 2 passwords strength minimum character-classes 4 passwords strength-check username admin password paSS1&word2 privilege 15 passwords lock-out 3 The following describes each line of this code: • The aaa authentication login “loc” local command creates a login authentication list called “loc” that contains the method local. • The line telnet command enters the configuration mode for the Telnet line. • The login authentication loc command assigns the loc login authentication list to be used for users accessing the switch via Telnet. • The enable password allows Telnet and SSH users access to privileged exec mode. It is required that an enable password be configured to allow local access users to elevate to privileged exec level. • The username guest password password command creates a user with the name “guest” and password “password”. A simple password can be configured here, since strength-checking has not yet been enabled. Configuring Authentication, Authorization, and Accounting 215 • The passwords strength minimum numeric-characters 2 command sets the minimum number of numeric characters required when password strength checking is enabled. This parameter is enabled only if the passwords strength minimum character-classes parameter is set to something greater than its default value of 0. • The passwords strength minimum character-classes 4 command sets the minimum number of character classes that must be present in the password. The possible character classes are: upper-case, lower-case, numeric and special. • The passwords strength-check command enables password strength checking. • The username admin password paSS1&word2 privilege 15 command creates a user with the name “admin” and password “paSS1&word2”. This user is enabled for privilege level 15. Note that, because password strength checking was enabled, the password was required to have at least two numeric characters, one uppercase character, one lowercase character, and one special character. • The passwords lock-out 3 command locks out a local user after three failed login attempts. This configuration allows either user to log into the switch. Both users will have privilege level 1. If no enable password was configured, neither user would be able to successfully execute the enable command, which grants access to Privileged EXEC mode, because there is no enable password set by default (the default method list for Telnet enable authentication is only the “enable” method). NOTE: It is recommend that the password strength checking and password lockout features be enabled when configuring local users. 216 Configuring Authentication, Authorization, and Accounting TACACS+ Authentication Example Use the following configuration to require TACACS+ authentication when logging in over a Telnet connection: aaa authentication login “tacplus” tacacs aaa authentication enable “tacp” tacacs tacacs-server host 1.2.3.4 key “secret” exit line telnet login authentication tacplus enable authentication tacp exit The following describes each line in the above configuration: • The aaa authentication login “tacplus” tacacs command creates a login authentication list called “tacplus” that contains the method tacacs. If this method returns an error, the user will fail to login. • The aaa authentication enable “tacp” tacacs command creates an enable authentication list called “tacp” that contains the method tacacs. If this method fails, then the user will fail to execute the enable command. • The tacacs-server host 1.2.3.4 command is the first step in defining a TACACS+ server at IP address 1.2.3.4. The result of this command is to place the user in tacacs-server mode to allow further configuration of the server. • The key “secret” command defines the shared secret. This must be the same as the shared secret defined on the TACACS+ server. • The line telnet command enters the configuration mode for the Telnet line. • The login authentication tacplus command assigns the tacplus login authentication method list to be used for users accessing the switch via Telnet. • The enable authentication tacp command assigns the tacp enable authentication method list to be used for users executing the enable command when accessing the switch via Telnet. Configuring Authentication, Authorization, and Accounting 217 NOTE: A user logging in with this configuration would be placed in User EXEC mode with privilege level 1. To access Privileged EXEC mode with privilege level 15, use the enable command. Public Key SSH Authentication Example The following is an example of a public key configuration for SSH login. Using a tool such as putty and a private/public key infrastructure, one can enable secure login to the Dell Networking switch without a password. Instead, a public key is used with a private key kept locally on the administrator's computer. The public key can be placed on multiple devices, allowing the administrator secure access without needing to remember multiple passwords. It is strongly recommended that the private key be protected with a password. This configuration requires entering a public key, which can be generated by a tool such as PuTTYgen. Be sure to generate the correct type of key. In this case, we use an RSA key with the SSH-2 version of the protocol. Switch Configuration username "admin" password f4d77eb781360c5711ecf3700a7af623 privilege 15 encrypted aaa authentication login "NOAUTH" line aaa authentication enable "NOAUTH" line crypto key generate rsa crypto key pubkey-chain ssh user-key "admin" rsa key-string row AAAAB3NzaC1yc2EAAAABJQAAAIBor6DPjYDpSy8Qcji68xrS/4Lf8c9Jq4xXKIZ5 Pvv20AkRFE0ifVI9EH4jyZagR3wzH5Xl9dyjA6bTuqMgN15C1xJC1l59FU88JaY7 ywGdRppmoaJrNRPM7RZtQPaDVIunzm3eMr9PywwQ0umsHWGNexUrDYHFWRIAmJp6 89AAxw== exit line ssh login authentication defaultList exit ip ssh server ip ssh pubkey-auth ip ssh protocol 2 The following describes each line of the above configuration: The username command creates a switch administrator. The aaa authentication lines set the login and enable methods for line to NOAUTH. The crypto key generate command generates an internal RSA key. This step is not required if an internal RSA key has been generated before on this switch. 218 Configuring Authentication, Authorization, and Accounting The crypto key pubkey-chain ssh command sets SSH to use a public key for the specified administrator login. The user login is specified by the username command, not the ias-user command. The key-string command enters the public key obtained from a key authority or from a tool such as PuTTyGen. This command is entered as a single line, not as four lines as it appears in the text above. The line ssh command sets the line method to SSH. The login authentication command configures the authentication method to the defaultList. The defaultList contains a single method — none — which is equivalent to no authentication. Since the authentication is provided by the public key, a second layer of authentication is not required. The last three lines enable the SSH server, configure it to use public key authentication, and specify use of the SSH-2 protocol. The following shows the configured authentication methods: console(config)#show authentication methods Login Authentication Method Lists --------------------------------defaultList : none networkList : local NOAUTH : line Enable Authentication Method Lists ---------------------------------enableList : enable none enableNetList : enable NOAUTH : line Line ------Console Telnet SSH HTTPS HTTP DOT1X Login Method List ----------------defaultList networkList defaultList Enable Method List -----------------enableList enableList enableList :local :local : Configuring Authentication, Authorization, and Accounting 219 PUTTY Configuration Main Screen On the following screen, the IP address of the switch is configured and SSH is selected as the secure login protocol. 220 Configuring Authentication, Authorization, and Accounting On the next screen, PUTTY is configured to use SSH-2 only. This is an optional step that accelerates the login process. Configuring Authentication, Authorization, and Accounting 221 The following screen is the key to the configuration. It is set to display the authentication banner, disable authentication with Pageant, disable keyboardinteractive authentication (unless desired), disable attempted changes of user name, and select the private key file used to authenticate with the switch. 222 Configuring Authentication, Authorization, and Accounting The following screen configures the user name to be sent to the switch. A user name is always required. Alternatively, leave Auto-login name blank and the system will prompt for a user name. Configuring Authentication, Authorization, and Accounting 223 After configuring Putty, be sure to save the configuration. The following screen shows the result of the login process. The user name is entered automatically and the switch confirms that public key authentication occurs. 224 Configuring Authentication, Authorization, and Accounting Authenticating Without a Public Key When authenticating without the public key, the switch prompts for the user name and password. This is a SSH function, not a switch function. If the user knows the administrator login and password, then they are able to authenticate in this manner. RADIUS Authentication Example Use the following configuration to require RADIUS authentication to login over a Telnet connection: aaa authentication login “rad” radius aaa authentication enable “raden” radius radius-server host 1.2.3.4 key “secret” exit line telnet login authentication rad enable authentication raden exit The following describes each line in the above configuration: Configuring Authentication, Authorization, and Accounting 225 226 • The aaa authentication login “rad” radius command creates a login authentication list called “rad” that contains the method radius. If this method returns an error, the user will fail to login. • The aaa authentication enable “raden” radius command creates an enable authentication list called “raden” that contains the method radius. If this method fails, then the user will fail to execute the enable command. • The radius-server host 1.2.3.4 command is the first step in defining a RADIUS server at IP address 1.2.3.4. The result of this command is to place the user in radius-server mode to allow further configuration of the server. • The key “secret” command defines the shared secret. This must be the same as the shared secret defined on the RADIUS server. • The line telnet command enters the configuration mode for the Telnet line. • The login authentication rad command assigns the rad login authentication method list to be used for users accessing the switch via Telnet. • The enable authentication raden command assigns the raden enable authentication method list to be used for users executing the enable command when accessing the switch via Telnet. Configuring Authentication, Authorization, and Accounting Authorization Examples Authorization allows the administrator to control which services a user is allowed to access. Some of the things that can be controlled with authorization include the user's initial privilege level and which commands the user is allowed to execute. When authorization fails, the user is denied access to the switch, even though the user has passed authentication. The following examples assume that the configuration used in the previous examples has already been applied. Local Authorization Example—Direct Login to Privileged EXEC Mode Apply the following configuration to use the local user database for authorization, such that a user can enter privileged EXEC mode directly: aaa authorization exec “locex” local line telnet authorization exec locex exit With the users that were previously configured, the guest user will still log into user EXEC mode, since the guest user only has privilege level 1 (the default). The admin user will be able to login directly to privileged EXEC mode since his privilege level was configured as 15. TACACS+ Authorization Example—Direct Login to Privileged EXEC Mode Apply the following configuration to use TACACS+ for authorization, such that a user can enter privileged EXEC mode directly: aaa authorization exec “tacex” tacacs line telnet authorization exec tacex exit Configure the TACACS+ server so that the shell service is enabled and the priv-lvl attribute is sent when user authorization is performed. For example: shell:priv-lvl=15 The following describes each line in the above configuration: Configuring Authentication, Authorization, and Accounting 227 • The aaa authorization exec “tacex” tacacs command creates an exec authorization method list called tacex which contains the method tacacs. • The authorization exec tacex command assigns the tacex exec authorization method list to be used for users accessing the switch via Telnet. Notes: • If the privilege level is zero (that is, blocked), then authorization will fail and the user will be denied access to the switch. • If the privilege level is higher than one, the user will be placed directly in Privileged EXEC mode. Note that all commands in Privileged EXEC mode require privilege level 15, so assigning a user a lower privilege level will be of no value. • A privilege level greater than 15 is invalid and treated as if privilege level zero had been supplied. • The shell service must be enabled on the TACACS+ server. If this service is not enabled, authorization will fail and the user will be denied access to the switch. TACACS+ Authorization Example—Administrative Profiles The switch should use the same configuration as for the previous authorization example. The TACACS+ server should be configured such that it will send the “roles” attribute. For example: shell:roles=router-admin The above example attribute will give the user access to the commands permitted by the router-admin profile. NOTE: If the priv-lvl attribute is also supplied, the user can also be placed directly into privileged EXEC mode. 228 Configuring Authentication, Authorization, and Accounting TACACS+ Authorization Example—Custom Administrative Profile This example creates a custom profile that allows the user to control user access to the switch by configuring a administrative profile that only allows access to AAA related commands. Use the following commands to create the administrative profile: admin-profile aaa rule 99 permit command “^show aaa .*” rule 98 permit command “^show authentication .*” rule 97 permit command "^show authorization .*” rule 96 permit command “^show accounting .*” rule 95 permit command “^show tacacs .*” rule 94 permit command “^aaa .*” rule 93 permit command “^line .*” rule 92 permit command “^login .*” rule 91 permit command “^authorization .*” rule 90 permit command “^accounting .*” rule 89 permit command “^configure .*” rule 88 permit command “^password .*” rule 87 permit command “^username .*” rule 86 permit command “^show user.*" rule 85 permit command “^radius-server .*” rule 84 permit command “^tacacs-server .*” rule 83 permit mode radius-auth-config rule 82 permit mode radius-acct-config rule 81 permit mode tacacs-config exit The following describes each line in the above configuration: • The admin-profile aaa command will create an administrative profile call aaa and place the user in admin-profile-config mode. • Each rule number permit command regex command allows any command that matches the regular expression. • Each rule number permit mode mode-name command allows all commands in the named mode. • The command rules use regular expressions as implemented by Henry Spencer's regex library (the POSIX 1003.2 compliant version). In the regular expressions used in this example, the caret (^) matches the null Configuring Authentication, Authorization, and Accounting 229 string at the beginning of a line, the period (.) matches any single character, and the asterisk (*) repeats the previous match zero or more times. • To assign this profile to a user, configure the TACACS+ server so that it sends the following “roles” attribute for the user: shell:roles=aaa If it is desired to also permit the user access to network-operator commands (basically, all the command in User EXEC mode), then the “roles” attribute would be configured as follows: shell:roles=aaa,network-operator TACACS+ Authorization Example—Per-command Authorization An alternative method for command authorization is to use the TACACS+ feature of per-command authorization. With this feature, every time the user enters a command, a request is sent to the TACACS+ server to ask if the user is permitted to execute that command. Exec authorization does not need to be configured to use per-command authorization. Apply the following configuration to use TACACS+ to authorize commands: aaa authorization commands “taccmd” tacacs line telnet authorization commands taccmd exit The following describes each line in the above configuration: • The aaa authorization commands “taccmd” tacacs command creates a command authorization method list called taccmd that includes the method tacacs. • The authorization commands taccmd command assigns the taccmd command authorization method list to be used for users accessing the switch via Telnet. The TACACS+ server must be configured with the commands that the user is allowed to execute. If the server is configured for command authorization as “None”, then no commands will be authorized. If both administrative 230 Configuring Authentication, Authorization, and Accounting profiles and per-command authorization are configured for a user, any command must be permitted by both the administrative profiles and by percommand authorization. RADIUS Authorization Example—Direct Login to Privileged EXEC Mode Apply the following configuration to use RADIUS for authorization, such that a user can enter privileged exec mode directly: aaa authorization exec “rad” radius line telnet authorization exec rad exit Configure the RADIUS server so that the RADIUS attribute Service Type (6) is sent with value Administrative. Any value other than Administrative is interpreted as privilege level 1. The following describes each line in the above configuration: • The aaa authorization exec “rad” radius command creates an exec authorization method list called “rad” that contains the method radius. • The authorization exec rad command assigns the rad exec authorization method list to be used for users accessing the switch via Telnet. Notes: • If the privilege level is zero (that is, blocked), then authorization will fail and the user will be denied access to the switch. • If the privilege level is higher than one, the user will be placed directly in Privileged EXEC mode. Note that all commands in Privileged EXEC mode require privilege level 15, so assigning a user a lower privilege level will be of no value. • A privilege level greater than 15 is invalid and treated as if privilege level zero had been supplied. Configuring Authentication, Authorization, and Accounting 231 RADIUS Authorization Example—Administrative Profiles The switch should use the same configuration as in the previous authorization example. The RADIUS server should be configured such that it will send the Cisco AV Pair attribute with the “roles” value. For example: shell:roles=router-admin The above example attribute gives the user access to the commands permitted by the router-admin profile. Using RADIUS Servers to Control Management Access The RADIUS client on the switch supports multiple RADIUS servers. When multiple authentication servers are configured, they can help provide redundancy. One server can be designated as the primary and the other(s) will function as backup server(s). The switch attempts to use the primary server first. if the primary server does not respond, the switch attempts to use the backup servers. A priority value can be configured to determine the order in which the backup servers are contacted. How Does RADIUS Control Management Access? Many networks use a RADIUS server to maintain a centralized user database that contains per-user authentication information. RADIUS servers provide a centralized authentication method for: • Telnet Access • Web Access • Console to Switch Access • Access Control Port (802.1X) Like TACACS+, RADIUS access control utilizes a database of user information on a remote server. Making use of a single database of accessible information—as in an Authentication Server—can greatly simplify the authentication and management of users in a large network. One such type of Authentication Server supports the Remote Authentication Dial In User Service (RADIUS) protocol as defined by RFC 2865. 232 Configuring Authentication, Authorization, and Accounting For authenticating users prior to access, the RADIUS standard has become the protocol of choice by administrators of large accessible networks. To accomplish the authentication in a secure manner, the RADIUS client and RADIUS server must both be configured with the same shared password or “secret”. This “secret” is used to generate one-way encrypted authenticators that are present in all RADIUS packets. The “secret” is never transmitted over the network. RADIUS conforms to a secure communications client/server model using UDP as a transport protocol. It is extremely flexible, supporting a variety of methods to authenticate and statistically track users. RADIUS is also extensible, allowing for new methods of authentication to be added without disrupting existing functionality. As a user attempts to connect to the switch management interface, the switch first detects the contact and prompts the user for a name and password. The switch encrypts the supplied information, and a RADIUS client transports the request to a pre-configured RADIUS server. Figure 10-1. RADIUS Topology Backup RADIUS Server Dell Networking Switch Primary RADIUS Server Management Network ` Management Host The server can authenticate the user itself or make use of a back-end device to ascertain authenticity. In either case a response may or may not be forthcoming to the client. If the server accepts the user, it returns a positive result with attributes containing configuration information. If the server Configuring Authentication, Authorization, and Accounting 233 rejects the user, it returns a negative result. If the server rejects the client or the shared secrets differ, the server returns no result. If the server requires additional verification from the user, it returns a challenge, and the request process begins again. If you use a RADIUS server to authenticate users, you must configure user attributes in the user database on the RADIUS server. The user attributes include the user name, password, and privilege level. NOTE: To set the privilege level, it is recommended to use the Service-Type attribute instead of the Cisco AV pair priv-lvl attribute. Which RADIUS Attributes Does the Switch Support? Table 10-5 lists the RADIUS attributes that the switch supports and indicates whether the 802.1X feature, user management feature, or Captive Portal feature supports the attribute. You can configure these attributes on the RADIUS server(s) when utilizing the switch RADIUS service. Table 10-5. Supported RADIUS Attributes Type RADIUS Attribute Name 802.1X User Manager Captive Portal 1 USER-NAME Yes Yes No 2 USER-PASSWORD Yes Yes No 4 NAS-IP-ADDRESS Yes No No 5 NAS-PORT Yes Yes No 6 SERVICE-TYPE No Yes No 11 FILTER-ID Yes No No 12 FRAMED-MTU Yes No No 15 LOGIN-SERVICE No Yes 18 REPLY-MESSAGE Yes Yes No 24 STATE Yes Yes No 25 CLASS Yes No No 26 VENDOR-SPECIFIC No Yes Yes 27 SESSION-TIMEOUT Yes No Yes 234 Configuring Authentication, Authorization, and Accounting Table 10-5. Supported RADIUS Attributes (Continued) Type RADIUS Attribute Name 802.1X User Manager Captive Portal 28 IDLE-TIMEOUT No No Yes 29 TERMINATION-ACTION Yes No No 30 CALLED-STATION-ID Yes No No 31 CALLING-STATION-ID Yes No No 32 NAS-IDENTIFIER Yes Yes No 40 ACCT-STATUS-TYPE Set by RADIUS client for Accounting Yes No 42 ACCT-INPUT-OCTETS Yes No No 43 ACCT-OUTPUT-OCTETS Yes No No 44 ACCT-SESSION-ID Set by RADIUS client for Accounting Yes No 46 ACCT-SESSION-TIME Yes Yes No 49 ACCT-TERMINATECAUSE Yes No No 52 ACCTINPUTGIGAWORDS Yes No No 53 ACCTOUTPUTGIGAWORDS Yes No No 61 NAS-PORT-TYPE Yes No No 64 TUNNEL-TYPE Yes No No 65 TUNNEL-MEDIUM-TYPE Yes No No 79 EAP-MESSAGE Yes No No 80 MESSAGEAUTHENTICAT Set by OR RADIUS client for Accounting Yes No 81 TUNNELPRIVATEGROUP-ID No No Yes Configuring Authentication, Authorization, and Accounting 235 How Are RADIUS Attributes Processed on the Switch? The following attributes are processed in the RADIUS Access-Accept message received from a RADIUS server: 236 • NAS-PORT—ifIndex of the port to be authenticated. • REPLY-MESSAGE—Trigger to respond to the Access-Accept message with an EAP notification. • STATE-RADIUS—Server state. Transmitted in Access-Request and Accounting-Request messages. • SESSION-TIMEOUT—Session timeout value for the session (in seconds). Used by both 802.1X and Captive Portal. • TERMINATION-ACTION—Indication as to the action taken when the service is completed. • EAP-MESSAGE—Contains an EAP message to be sent to the user. This is typically used for MAB clients. • VENDOR-SPECIFIC—The following Cisco AV Pairs are supported: – shell:priv-lvl – shell:roles • FILTER-ID—Name of the filter list for this user. • TUNNEL-TYPE—Used to indicate that a VLAN is to be assigned to the user when set to tunnel type VLAN (13). • TUNNEL-MEDIUM-TYPE—Used to indicate the tunnel medium type. Must be set to medium type 802 (6) to enable VLAN assignment. • TUNNEL-PRIVATE-GROUP-ID—Used to indicate the VLAN to be assigned to the user. May be a string which matches a preconfigured VLAN name or a VLAN id. If a VLAN id is given, the string must only contain decimal digits. Configuring Authentication, Authorization, and Accounting Using TACACS+ Servers to Control Management Access TACACS+ (Terminal Access Controller Access Control System) provides access control for networked devices via one or more centralized servers. TACACS+ simplifies authentication by making use of a single database that can be shared by many clients on a large network. TACACS+ uses TCP to ensure reliable delivery and a shared key configured on the client and daemon server to encrypt all messages. If you configure TACACS+ as the authentication method for user login and a user attempts to access the user interface on the switch, the switch prompts for the user login credentials and requests services from the TACACS+ client. The client then uses the configured list of servers for authentication, and provides results back to the switch. Figure 10-2 shows an example of access management using TACACS+. Figure 10-2. Basic TACACS+ Topology Backup TACACS+ Server Dell Networking Switch Primary TACACS+ Server Management Network ` Management Host You can configure the TACACS+ server list with one or more hosts defined via their network IP address. You can also assign each a priority to determine the order in which the TACACS+ client will contact them. TACACS+ contacts the server when a connection attempt fails or times out for a higher priority server. Configuring Authentication, Authorization, and Accounting 237 You can configure each server host with a specific connection type, port, timeout, and shared key, or you can use global configuration for the key and timeout. The TACACS+ server can do the authentication itself, or redirect the request to another back-end device. All sensitive information is encrypted and the shared secret is never passed over the network; it is used only to encrypt the data. Which TACACS+ Attributes Does the Switch Support? Table 10-6 lists the TACACS+ attributes that the switch supports and indicates whether the authorization or accounting service supports sending or receiving the attribute. The authentication service does not use attributes. You can configure these attributes on the TACACS+ server(s) when utilizing the switch TACACS+ service. Table 10-6. Supported TACACS+ Attributes Attribute Name Exec Authorization Command Authorization Accounting cmd both (optional) sent sent cmd-arg sent elapsed-time priv-lvl sent received protocol sent roles both (optional) service=shell both sent sent start-time sent stop-time sent 238 Configuring Authentication, Authorization, and Accounting Default Configurations Method Lists The method lists shown in Table 10-7 are defined by default. They cannot be deleted, but they can be modified. Using the “no” command on these lists will return them to their default configuration. Table 10-7. Default Method Lists AAA Service (type) List Name List Methods Authentication (login) defaultList none Authentication (login) networkList local Authentication (enable) enableList enable none Authentication (enable) enableNetList enable Authorization (exec) dfltExecAuthList none Authorization (commands) dfltCmdAuthList none Accounting (exec) dfltExecList tacacs (start-stop) Accounting (commands) dfltCmdList tacacs (stop-only) Access Lines (AAA) Table 10-8 shows the method lists assigned to the various access lines by default. Table 10-8. Default AAA Methods AAA Service (type) Console Telnet SSH Authentication (login) defaultList networkList networkList Authentication (enable) enableList enableNetList enableNetList Authorization (exec) dfltExecAuthList dfltExecAuthList dfltExecAuthList Authorization (commands) dfltCmdAuthList dfltCmdAuthList dfltCmdAuthList Configuring Authentication, Authorization, and Accounting 239 Table 10-8. Default AAA Methods (Continued) AAA Service (type) Console Telnet SSH Accounting (exec) none none none Accounting (commands) none none none Access Lines (Non-AAA) Table 10-9 shows the default configuration of the access lines that do not use method lists. Table 10-9. Default Configuration for Non-AAA Access Lines Access Line Authentication Authorization HTTP local n/a HTTPS local n/a 802.1X none none Administrative Profiles The administrative profiles shown in Table 10-10 are system-defined and may not be deleted or altered. To see the rules in a profile, use the show adminprofiles name profile name command. Table 10-10. Default Administrative Profiles Name Description network-admin Allows access to all commands. network-security Allows access to network security features such as 802.1X, Voice VLAN, Dynamic ARP Inspection and IP Source Guard. router-admin Allows access to Layer 3 features such as IPv4 Routing, IPv6 Routing, OSPF, RIP, etc. multicast-admin Allows access to multicast features at all layers, this includes L2, IPv4 and IPv6 multicast, IGMP, IGMP Snooping, etc. dhcp-admin Allows access to DHCP related features such as DHCP Server and DHCP Snooping. 240 Configuring Authentication, Authorization, and Accounting Table 10-10. Default Administrative Profiles (Continued) Name Description CP-admin Allows access to the Captive Portal feature. network-operator Allows access to all User EXEC mode commands and show commands. Configuring Authentication, Authorization, and Accounting 241 242 Configuring Authentication, Authorization, and Accounting 11 Monitoring and Logging System Information This chapter provides information about the features you use to monitor the switch, including logging, cable tests, and email alerting. The topics covered in this chapter include: • System Monitoring Overview • Default Log Settings • Monitoring System Information and Configuring Logging (Web) • Monitoring System Information and Configuring Logging (CLI) • Logging Configuration Examples System Monitoring Overview What System Information Is Monitored? The CLI and web-based interfaces provide information about physical aspects of the switch, such as system health and cable diagnostics, as well as information about system events, such as management login history. The switch also reports system resource usage. The system logging utility can monitor a variety of events, including the following: • System events — System state changes and errors that range in severity from Emergency to Debug • Audit events — Attempts to login or logout from the switch and attempts to perform any operations with files on the flash drive • CLI commands — Commands executed from the CLI • Web page visits — Pages viewed by using OpenManage Switch Administrator • SNMP events — SNMP set operations Monitoring and Logging System Information 243 Why Is System Information Needed? The information the switch provides can help you troubleshoot issues that might be affecting system performance. The cable diagnostics test help you troubleshoot problems with the physical connections to the switch. Auditing access to the switch and the activities an administrator performed while managing the switch can help provide security and accountability. Where Are Log Messages Sent? The messages the switch generates in response to events, faults, errors, and configuration changes can be recorded in several locations. By default, these messages are stored locally on the switch in the RAM (cache). This collection of log files is called the RAM log or buffered log. When the RAM log file reaches the configured maximum size, the oldest message is deleted from the RAM when a new message is added. If the system restarts, all messages are cleared. In addition to the RAM log, you can specify that log files are sent to the following sources: 244 • Console — If you are connected to the switch CLI through the console port, messages display to the screen as they are generated. Use the terminal monitor command to control logging of messages to the console when connected via Telnet or SSH. • Log file — Messages sent to the log file are saved in the flash memory and are not cleared when the system restarts. • Remote server — Messages can be sent to a remote log server for viewing and storage. • Email — Messages can be sent to one or more email addresses. You must configure information about the network Simple Mail Transport Protocol SMTP) server for email to be successfully sent from the switch. Monitoring and Logging System Information What Are the Severity Levels? For each local or remote log file, you can specify the severity of the messages to log. Each severity level is identified by a name and a number. Table 11-1 provides information about the severity levels. Table 11-1. Log Message Severity Severity Keyword Severity Level Description emergencies 0 The switch is unusable. alerts 1 Action must be taken immediately. critical 2 The switch is experiencing critical conditions. errors 3 The switch is experiencing error conditions. warnings 4 The switch is experiencing warning conditions. notification 5 The switch is experiencing normal but significant conditions. informational 6 The switch is providing non-critical information. debugging 7 The switch is providing debug-level information. When you specify the severity level, messages with that severity level and higher are sent to the log file. For example, if you specify the severity level as critical, messages with a severity level of alert and emergency are also logged. When you specify the severity level in a CLI command, you can use the keyword or the numerical level. What Are the System Startup and Operation Logs? Two types of log files exist in flash (persistent) memory: • The first log type is the system startup log. The system startup log stores the first 32 messages received after system reboot. The log file stops when it is full. • The second log type is the system operation log. The system operation log stores the last 1000 messages received during system operation. The oldest messages are overwritten when the file is full. A message is only logged in one file. On system startup, if the Log file is enabled, the startup log stores messages up to its limit. Then the operation log begins to store the messages. Monitoring and Logging System Information 245 To view the log messages in the system startup and operational log files, you must download the log files to an administrative host. The startup log files are named slogX.txt and the operation log files are named ologX.txt. When enabled, the system stores the startup and operation log files for the last three switch boots. The current log files have a zero (0) in the file name (replacing the X in the name as shown above), the prior log files contain a one (1) in the name, and the oldest log files contain a two (2) in the name. For more information about downloading files, see "Managing Images and Files" on page 359. What Is the Log Message Format? The first part of the log message up to the first left bracket is fixed by the Syslog standard (RFC 3164). The second part up to the two percent signs is standardized for all Dell Networking logs. The variable text of the log message follows. The log message is limited to 96 bytes. Each log message uses the following format: 246 • PRI—This consists of the facility code (see RFC 3164) multiplied by 8 and added to the severity. The log messages use the local7 facility code (23). This implies that a message of severity 0 will have a priority of 184 and a message of severity 7 will have a priority of 191. • Timestamp—This is the system up time. For systems that use SNTP, this is UTC. When time zones are enabled, local time will be used. • Host IP address—This is the IP address of the local system. Monitoring and Logging System Information • Stack ID —This is the assigned stack ID. For the Dell Networking N2000, N3000, and N4000 series switches, the stack ID number is always 1. The number 1 is used for systems without stacking ability. The top of stack is used to collect messages for the entire stack. • Component name—The component name for the logging component. Component “UNKN” is substituted for components that do not identify themselves to the logging component. • Thread ID—The thread ID of the logging component. • File name —The name of the file containing the invoking macro. • Line number —The line number which contains the invoking macro. • Sequence number —The message sequence number for this stack component. Sequence numbers may be skipped because of filtering but are always monotonically increasing on a per-stack member basis. • Message — Contains the text of the log message. What Factors Should Be Considered When Configuring Logging? Dell recommends that network administrators deploy a syslog server in their network and configure all switches to log messages to the syslog server. Switch administrators should also consider enabling persistent logging on the switch. When managing logs on a stack of switches, the RAM log and persistent log files exist only on the top of stack platform. Other platforms in the stack forward their messages to the top of stack log. Monitoring and Logging System Information 247 Default Log Settings System logging is enabled, and messages are sent to the console (severity level: warning and above), and RAM log (severity level: informational and above). Switch auditing, CLI command logging, Web logging, and SNMP logging are disabled. By default, no messages are sent to the log file that is stored in flash, and no remote log servers are defined. Email alerting is disabled, and no recipient email address is configured. Additionally, no mail server is defined. If you add a mail server, by default, no authentication or security protocols are configured, and the switch uses TCP port 25 for SMTP. After you enable email alerting and configure the mail server and recipient email address, log messages with a severity level of emergency and alert are sent immediately with each log message in a separate mail. The email subject is “Urgent Log Messages.” Log messages with a severity level of critical, error, and warning are sent periodically in a single email. The email subject is “Non Urgent Log Messages.” Messages with a severity level of notice and below are not sent in an email. 248 Monitoring and Logging System Information Monitoring System Information and Configuring Logging (Web) This section provides information about the OpenManage Switch Administrator pages to use to monitor system information and configure logging on the Dell Networking N2000, N3000, and N4000 series switches. For details about the fields on a page, click at the top of the page. Device Information The Device Information page displays after you successfully log on to the switch by using the Dell OpenManage Switch Administrator. This page is a virtual representation of the switch front panel. Use the Device Information page to view information about the port status, or system status, and the switch stack. Click on a port to access the Port Configuration page for the selected port. To display the Device Information page, click Home in the navigation panel. Figure 11-1. Device Information Click the Stack View link to view front panel representations for all units in the stack. Monitoring and Logging System Information 249 Figure 11-2. Stack View For more information about the device view features, see "Understanding the Device View" on page 132. 250 Monitoring and Logging System Information System Health Use the Health page to view status information about the switch power and ventilation sources. To display the Health page, click System → General → Health in the navigation panel. Figure 11-3. Health Monitoring and Logging System Information 251 System Resources Use the System Resources page to view information about memory usage and task utilization. To display the System Resources page, click System → General → System Resources in the navigation panel. Figure 11-4. System Resources 252 Monitoring and Logging System Information Unit Power Usage History Use the Unit Power Usage History page to view information about switch power consumption. To display the Unit Power Usage History page, click System → General → Unit Power Usage History in the navigation panel. Figure 11-5. Unit Power Usage History Monitoring and Logging System Information 253 Integrated Cable Test for Copper Cables Use the Integrated Cable Test for Copper Cables page to perform tests on copper cables. Cable testing provides information about where errors occurred in the cable, the last time a cable test was performed, and the type of cable error which occurred. The tests use Time Domain Reflectometry (TDR) technology to test the quality and characteristics of a copper cable attached to a port. Cables up to 120 meters long can be tested. Cables are tested when the ports are in the down state, with the exception of the Approximated Cable Length test. SFP, SFP+, and QSFP cables with passive copper assemblies are not capable of performing TDR tests. NOTE: Cable diagnostics may give misleading results if any green Ethernet modes are enabled on the port. Disable EEE or energy-detect mode prior to running any cable diagnostics. To display the Integrated Cable Test for Copper Cables page, click System → Diagnostics → Integrated Cable Test in the navigation panel. Figure 11-6. Integrated Cable Test for Copper Cables 254 Monitoring and Logging System Information To view a summary of all integrated cable tests performed, click the Show All link. Figure 11-7. Integrated Cable Test Summary Optical Transceiver Diagnostics Use the Transceiver Diagnostics page to perform tests on Fiber Optic cables. To display the Transceiver Diagnostics page, click System → Diagnostics → Transceiver Diagnostics in the navigation panel. NOTE: Optical transceiver diagnostics can be performed only when the link is present. Monitoring and Logging System Information 255 Figure 11-8. Transceiver Diagnostics To view a summary of all optical transceiver diagnostics tests performed, click the Show All link. Figure 11-9. Transceiver Diagnostics Summary 256 Monitoring and Logging System Information Log Global Settings Use the Global Settings page to enable logging globally, to enable other types of logging. You can also specify the severity of messages that are logged to the console, RAM log, and flash-based log file. The Severity table lists log messages from the highest severity (Emergency) to the lowest (Debug). When you select a severity level, all higher levels are automatically selected. To prevent log messages from being sent to the console, RAM log, or flash log file, clear all check boxes in the Severity column. To display the Global Settings page, click System → Logs → Global Settings in the navigation panel. Figure 11-10. Global Settings Monitoring and Logging System Information 257 RAM Log Use the RAM Log page to view information about specific RAM (cache) log entries, including the time the log was entered, the log severity, and a description of the log. To display the RAM Log, click System → Logs → RAM Log in the navigation panel. Figure 11-11. 258 RAM Log Table Monitoring and Logging System Information Log File The Log File contains information about specific log entries, including the time the log was entered, the log severity, and a description of the log. To display the Log File, click System → Logs → Log File in the navigation panel. Figure 11-12. Log File Syslog Server Use the Remote Log Server page to view and configure the available syslog servers, to define new syslog servers, and to set the severity of the log events sent to the syslog server. To display the Remote Log Server page, click System → Logs → Remote Log Server. Monitoring and Logging System Information 259 Figure 11-13. Remote Log Server Adding a New Remote Log Server To add a syslog server: 1 Open the Remote Log Server page. 2 Click Add to display the Add Remote Log Server page. 3 Specify the IP address or hostname of the remote server. 4 Define the UDP Port and Description fields. 260 Monitoring and Logging System Information Figure 11-14. Add Remote Log Server 5 Select the severity of the messages to send to the remote server. NOTE: When you select a severity level, all higher (numerically lower) severity levels are automatically selected. 6 Click Apply. Click the Show All link to view or remove remote log servers configured on the system. Figure 11-15. Show All Log Servers Monitoring and Logging System Information 261 Email Alert Global Configuration Use the Email Alert Global Configuration page to enable the email alerting feature and configure global settings so that system log messages can be sent to from the switch to one or more email accounts. To display the Email Alert Global Configuration page, click System → Email Alerts → Email Alert Global Configuration in the navigation panel. Figure 11-16. Email Alert Global Configuration Email Alert Mail Server Configuration Use the Email Alert Mail Server Configuration page to configure information about the mail server the switch uses for sending email alert messages. To display the Email Alert Mail Server Configuration page, click System → Email Alerts → Email Alert Mail Server Configuration in the navigation panel. 262 Monitoring and Logging System Information Figure 11-17. Email Alert Mail Server Configuration Adding a Mail Server To add a mail server: 1 Open the Email Alert Mail Server Configuration page. 2 Click Add to display the Email Alert Mail Server Add page. 3 Specify the hostname of the mail server. Figure 11-18. Add Mail Server 4 Click Apply. 5 If desired, click Configuration to return to the Email Alert Mail Server Configuration page to specify port and security settings for the mail server. Click the Show All link to view or remove mail servers configured on the switch. Monitoring and Logging System Information 263 Figure 11-19. Show All Mali Servers Email Alert Subject Configuration Use the Email Alert Subject Configuration page to configure the subject line for email alerts that are sent by the switch. You can customize the subject for the message severity and entry status. To display the Email Alert Subject Configuration page, click System → Email Alerts → Email Alert Subject Configuration in the navigation panel. Figure 11-20. Email Alert Subject Configuration To view all configured email alert subjects, click the Show All link. 264 Monitoring and Logging System Information Figure 11-21. View Email Alert Subjects Email Alert To Address Configuration Use the Email Alert To Address Configuration page to specify where the email alerts are sent. You can configure multiple recipients and associate different message severity levels with different recipient addresses. To display the Email Alert To Address Configuration page, click System → Email Alerts → Email Alert To Address Configuration in the navigation panel. Figure 11-22. Email Alert To Address Configuration To view configured recipients, click the Show All link. Monitoring and Logging System Information 265 Figure 11-23. View Email Alert To Address Configuration Email Alert Statistics Use the Email Alert Statistics page to view the number of emails that were successfully and unsuccessfully sent, and when emails were sent. To display the Email Alert Statistics page, click System → Email Alerts → Email Alert Statistics in the navigation panel. Figure 11-24. 266 Email Alert Statistics Monitoring and Logging System Information Monitoring System Information and Configuring Logging (CLI) This section provides information about the commands you use to configure information you use to monitor the Dell Networking N2000, N3000, and N4000 series switches. For more information about these commands, see the Dell Networking N2000, N3000, and N4000 Series Switches CLI Reference Guide at support.dell.com/manuals. Viewing System Information and Enabling the Locator LED Beginning in Privileged EXEC mode, use the following commands to view system health and resource information and to enable the switch locator LED. Command Purpose show system Display various system information. show system power Displays the power supply status. show system temperature Displays the system temperature and fan status. show memory cpu Displays the total and available RAM space on the switch. show process cpu Displays the CPU utilization for each process currently running on the switch. locate [switch unit] [time time] Enable the switch locator LED located on the back panel of the switch. Optionally, you can specify the unit to identify within a switch stack and the length of time that the LED blinks. Command Purpose show system Display various system information. show system power Displays the power supply status. show system temperature Displays the system temperature and fan status. show memory cpu Displays the total and available RAM space on the switch. Monitoring and Logging System Information 267 Command Purpose show process cpu Displays the CPU utilization for each process currently running on the switch. Running Cable Diagnostics Beginning in Privileged EXEC mode, use the following commands to run the cable diagnostic tests. NOTE: Cable diagnostics may give misleading results if green mode is enabled on the port. Disable green mode prior to running any cable diagnostics. Command Purpose test copper-port tdr Perform the Time Domain Reflectometry (TDR) test to diagnose the quality and characteristics of a copper cable attached to the specified port. SFP, SFP+, and QSFP cables with passive copper assemblies are not capable of performing TDR tests. interface CAUTION: Issuing the test copper-port tdr command will bring the interface down. NOTE: To ensure accurate measurements, disable all Green Ethernet modes (EEE or energy-detect mode) on the port before running the test. The interface is specified in unit/slot/port format. For example 1/0/3 is GbE interface 3 on unit 1 of the stack. show copper-ports tdr [interface] Display the diagnostic information collected by the test copper-port tdr command for all copper interfaces or a specific interface. show fiber-ports optical- Display the optical transceiver diagnostics for all fiber transceiver [interface] ports. Include the interface option to show information for the specified port. 268 Monitoring and Logging System Information Configuring Local Logging Beginning in Privileged EXEC mode, use the following commands to configure the type of messages that are logged and where the messages are logged locally. Command Purpose configure Enter Global Configuration mode. logging on Globally enables logging. logging audit Enable switch auditing. logging cli-command Enable CLI command logging logging web-sessions Enable logging of the switch management Web page visits. logging snmp Enable logging of SNMP set commands. terminal monitor Enable display of system messages on the console for Telnet/SSH sessions. logging Enable logging to the specified file. Optionally, you can {buffered|console| file} define a logging discriminator to help filter log messages [severity] and set the severity of the messages to log. • buffered — Enables logging to the RAM file (cache). If the switch resets, the buffered logs are cleared. • console — Enables logging to the screen when you are connected to the CLI through the console port. • file — Enables logging to the startup and operational log files on the flash. • discriminator disc-name — (Optional) Include a message discriminator to help filter log messages. The disc-name can contain up to eight alphanumeric characters. Spaces are not permitted. • severity — (Optional) Enter the number or name of the desired severity level. For information about severity levels, see Table 11-1. logging facility facility- type CTRL + Z Set the facility for logging messages. Permitted facilitytype values are local0, local1, local2, local3, local4, local5, local 6, local7 Exit to Privileged EXEC mode. Monitoring and Logging System Information 269 Command Purpose show logging Displays the state of logging and the syslog messages stored in the internal buffer. show logging file View information about the flash (persistent) log file. clear logging Use to clear messages from the logging buffer. Configuring Remote Logging Beginning in Privileged EXEC mode, use the following commands to define a remote server to which the switch sends log messages. Command Purpose configure Enter Global Configuration mode. logging {ip-address| hostname} Define a remote log server and enter the configuration mode for the specified log server. description description Describe the log server. Use up to 64 characters. If the description includes spaces, surround it with quotation marks. level severity Specify the severity level of the logs that should be sent to the remote log server. For information about severity levels, see Table 11-1. port udp-port Specify the UDP port to use for sending log messages. The range is 1 to 65535, and the default is 514. CTRL + Z Exit to Privileged EXEC mode. show syslog-servers Verify the remote log server configuration. 270 Monitoring and Logging System Information Configuring Mail Server Settings Beginning in Privileged EXEC mode, use the following commands to configure information about the mail server (SMTP host) on the network that will initially receive the email alerts from the switch and relay them to the correct recipient. Command Purpose configure Enter Global Configuration mode. mail-server ip-address Specify the IP address of the SMTP server on the network and enter the configuration mode for the mail server. security {tlsvl|none} (Optional) Specify the security protocol to use with the mail server. port {25|465} Configure the TCP port to use for SMTP, which can be 25 (SMTP) or 465 (SMTP over SSL). username username If the SMTP server requires authentication, specify the username to use for the switch. The same username and password settings must be configured on the SMTP host. password password If the SMTP server requires authentication from clients, specify the password to associate with the switch username. CTRL + Z Exit to Privileged EXEC mode. show mail-server all config View mail server configuration information for all configured mail servers. Monitoring and Logging System Information 271 Configuring Email Alerts for Log Messages Beginning in Privileged EXEC mode, use the following commands to configure email alerts so that log messages are sent to the specified address. Command Purpose configure Enter Global Configuration mode. logging email [severity] Enable email alerting and determine which non-critical log messages should be emailed. Including the severity value sets the lowest severity for which log messages are emailed. These messages are collected and sent in a single email at the configured log duration. severity — (Optional) Enter the number or name of the severity level for non-critical messages. Log messages at or above this severity level are emailed. For information about severity levels, see Table 11-1. Log messages below the specified level are not emailed. logging email urgent {severity | none} Determine which log messages are critical and should be sent in a single email as soon as they are generated. severity — (Optional) Enter the number or name of the severity level for critical messages. For information about severity levels, see Table 11-1. logging email logtime Specify how often to send the non-critical email alerts that have been collected. . The valid range is 30 - 1440 minutes. logging email messagetype {urgent | nonurgent | both} to-addr Specify the email address of the recipient for log messages. minutes email-address logging email from-addr Specify the email address of the sender, which is the switch. email-address logging email messagetype {urgent | nonurgent | both} subject Specify the text that will appear in the subject line of email alerts sent by the switch. subject 272 Monitoring and Logging System Information Command Purpose logging email test message-type {urgent | non-urgent | both} message-body body Send a test email to the configured recipient to verify that the feature is properly configured. CTRL + Z Exit to Privileged EXEC mode. show logging email config View the configured settings for email alerts. show logging email statistics View information about the number of emails sent and the time they were sent. clear logging email statistics Clear the email alerting statistics. Monitoring and Logging System Information 273 Logging Configuration Examples This section contains the following examples: • Configuring Local and Remote Logging • Configuring Email Alerting Configuring Local and Remote Logging This example shows how to enable switch auditing and CLI command logging. Log messages with a severity level of Notification (level 5) and above are sent to the RAM (buffered) log. Emergency, Critical, and Alert (level 2) log messages are written to the log file on the flash drive. All log messages are displayed on the console and sent to a remote syslog server. To configure the switch: 1 Enable switch auditing and CLI command logging. console#configure console(config)#logging audit console(config)#logging cli-command 2 Specify where the logs are sent locally and what severity level of message is to be logged. You can specify the severity as the level number, as shown in the first two commands, or as the keyword, shown in the third command. console(config)#logging buffered 5 console(config)#logging file 2 console(config)#logging console debugging 3 Define the remote log server. console(config)#logging 192.168.2.10 console(Config-logging)#description "Syslog Server" console(Config-logging)#level debug console(Config-logging)#exit console(config)#exit 274 Monitoring and Logging System Information 4 Verify the remote log server configuration. console#show syslog-servers IP Address/Hostname Port ------------------------- -----192.168.2.10 514 Severity Description -------------- ---------debugging Syslog Server 5 Verify the local logging configuration and view the log messages stored in the buffer (RAM log). console#show logging Logging is enabled Console Logging: level debugging. Console Messages: 748 Dropped. Buffer Logging: level notifications. Buffer Messages: 79 Logged, File Logging: level critical. File Messages: 973 Dropped. CLI Command Logging : enabled Switch Auditing : enabled Web Session Logging : disabled SNMP Set Command Logging : disabled Syslog server 192.168.2.10 logging: debug. Messages: 0 dropped 412 Messages dropped due to lack of resources. Buffer Log: <186> FEB 02 05:53:03 0.0.0.0-1 UNKN[1073741088]: bootos.c(232) 1 %% Event(0xaaaaaaaa) <189> FEB 02 05:53:03 0.0.0.0-1 UNKN[1073741088]: bootos.c(248) 2 %% Starting code... BSP initialization complete, starting application. --More-- or (q)uit Monitoring and Logging System Information 275 Configuring Email Alerting The commands in this example define the SMTP server to use for sending email alerts. The mail server does not require authentication and uses the standard TCP port for SMTP, port 25, which are the default values. Only Emergency messages (severity level 0) will be sent immediately as individual emails, and messages with a severity of alert, critical, and error (levels 1-3) will be sent in a single email every 120 minutes. Warning, notice, info, and debug messages are not sent in an email. The email the administrator will in the inbox has a format similar to the following: Figure 11-25. Email Alert Message Format For emergency-level messages, the subject is LOG MESSAGE EMERGENCY. For messages with a severity level of alert, critical, and error, the subject is LOG MESSAGE. To configure the switch: 1 Specify the mail server to use for sending messages. console#configure console(config)#mail-server ip-address 192.168.2.34 276 Monitoring and Logging System Information 2 Configure the username and password that the switch must use to authenticate with the mail server. console(Mail-Server)#username switchN3048 console(Mail-Server)#password passwordN3048 console(Mail-Server)#exit 3 Configure emergencies and alerts to be sent immediately, and all other messages to be sent in a single email every 120 minutes. console(config)#logging email error console(config)#logging email urgent emergency console(config)#logging email logtime 120 4 Specify the email address of the sender (the switch). console(config)#logging email from-addr N3048_noreply@dell.com 5 Specify the address where email alerts should be sent. console(config)#logging email message-type both to-addr administrator@dell.com 6 Specify the text that will appear in the email alert Subject line. console(config)#logging email message-type urgent subject "LOG MESSAGES - EMERGENCY" console(config)#logging email message-type nonurgent subject "LOG MESSAGES" 7 Verify the configuration. console#show mail-server all config Mail Servers Configuration: No of mail servers configured.................. 1 Email Email Email Email Email Alert Alert Alert Alert Alert Mail Server Address................ Mail Server Port................... SecurityProtocol................... Username........................... Password........................... 192.168.2.34 25 none switchN3048 passwordN3048 console#show logging email config Monitoring and Logging System Information 277 Email Alert Logging............................ Email Alert From Address....................... N3048_noreply@dell.com Email Alert Urgent Severity Level.............. Email Alert Non Urgent Severity Level.......... Email Alert Trap Severity Level................ Email Alert Notification Period................ enabled 0 3 6 120 min Email Alert To Address Table: For Msg Type..........................1 Address1..............................administrator@dell.com For Msg Type..........................2 Address1..............................administrator@dell.com Email Alert Subject Table : For Msg Type 1, subject is............LOG MESSAGES - EMERGENCY For Msg Type 2, subject is............LOG MESSAGE 278 Monitoring and Logging System Information 12 Managing General System Settings This chapter describes how to set system information, such as the hostname, and time settings, and how to select the Switch Database Management (SDM) template to use on the switch. For the N2000 and N3000 series switches, this chapter also describes how to configure the Power over Ethernet (PoE) settings. For the N3000 series switches, this chapter also describes how to view backpanel expansion slot information. The topics covered in this chapter include: • System Settings Overview • Default General System Information • Configuring General System Settings (Web) • Configuring System Settings (CLI) • General System Settings Configuration Examples System Settings Overview The system settings include the information described in Table 12-1. This information helps identify the switch. Table 12-1. System Information Feature Description System Name The switch name (host name). If you change the system name, the CLI prompt changes from console to the system name. System contact Identifies the person to contact for information regarding the switch. System location Identifies the physical location of the switch. Asset tag Uniquely identifies the switch. Some organizations use asset tags to identify, control, and track each piece of equipment. Managing General System Settings 279 Table 12-1. System Information (Continued) Feature Description CLI Banner Displays a message upon connecting to the switch or logging on to the switch by using the CLI. SDM Template Determines the maximum resources a switch or router can use for various features. For more information, see "What Are SDM Templates?" on page 281 The switch can obtain the time from a Simple Network Time Protocol (SNTP) server, or you can set the time manually. Table 12-2 describes the settings that help the switch keep track of time. Table 12-2. Time Settings Feature Description SNTP Controls whether the switch obtains its system time from an SNTP server and whether communication with the SNTP server requires authentication and encryption. You can configure information for up to eight SNTP servers. The SNTP client on the switch can accept updates from both IPv4 and IPv6 SNTP servers. Real time clock (RTC) If SNTP is disabled, you can manually enter the system time and date. Time Zone Allows you to specify the offset from Coordinated Universal Time (UTC), which is also known as Greenwich Mean Time (GMT). Summer Time In some regions, the time shifts by one hour in the fall and spring. In the United States, this is called daylight saving time. The Dell Networking N2024P/N2048P and N3024P/N3048P switch ports are IEEE 802.1at-2009-compliant (PoE Plus) and can provided up to 34.2W of power per port. For more information about PoE Plus support, see "What Are the Key PoE Plus Features for the N2024P/N2048P and N3024P/N3048P Switches?" on page 285 280 Managing General System Settings Why Does System Information Need to Be Configured? Configuring system information is optional. However, it can be helpful in providing administrative information about the switch. For example, if you manage several standalone Dell Networking series switches and have Telnet sessions open with several different switches, the system name can help you quickly identify the switch because the host name replaces console as the CLI command prompt. The Banner can provide information about the switch status. For example, if multiple users connect to the switch, the message of the day (MOTD) banner might alert everyone who connects to the switch about a scheduled switch image upgrade. What Are SDM Templates? An SDM template is a description of the maximum resources a switch or router can use for various features. Different SDM templates allow different combinations of scaling factors, enabling different allocations of resources depending on how the device is used. In other words, SDM templates enable you to reallocate system resources to support a different mix of features based on your network requirements. Dell Networking series switches support the following three templates: • Dual IPv4 and IPv6 (default) • IPv4 Routing • IPv4 Data Center Table 12-3 describes the parameters that are scaled for each template and the per-template maximum value of the parameter. Table 12-3. SDM Template Parameters and Values Parameter Dual IPv4/IPv6 Dual IPv4/IPv6 IPv4 Only Data Center IPv4 Data Center N2000 1024 0 1024 0 N3000 4096 4096 6144 0 N4000 4096 4096 6144 4096 ARP entries Managing General System Settings 281 Table 12-3. SDM Template Parameters and Values (Continued) Parameter Dual IPv4/IPv6 Dual IPv4/IPv6 IPv4 Only Data Center IPv4 Data Center N2000 256 0 512 0 N3000 8160 8160 12288 0 N4000 8160 8160 12288 8160 N2000 512 0 0 0 N3000 2560 2560 0 0 N4000 1024 1024 0 0 N2000 128 0 0 0 N3000 4096 4096 0 0 N4000 4096 4096 0 0 N2000 1 0 1 0 N3000 4 16 16 0 N4000 4 4 16 16 N2000 0 0 0 0 N3000 1536 1536 2048 0 N4000 512 512 1024 2048 N2000 0 0 0 0 N3000 512 512 0 0 N4000 256 256 0 0 IPv4 unicast routes IPv6 Neighbor Discovery Protocol (NDP) entries IPv6 unicast routes ECMP next hops IPv4 multicast routes IPv6 multicast routes 282 Managing General System Settings SDM Template Configuration Guidelines When you configure the switch to use an SDM template that is not currently in use, you must reload the switch for the configuration to take effect. NOTE: If you attach a unit to a stack and its template does not match the stack's template, then the new unit will automatically reboot using the template used by the management unit. To avoid the automatic reboot, you may first set the template to the template used by the management unit. Then power off the new unit, attach it to the stack, and power it on. If the IPv4 Routing or IPv4 Data Center template is currently in use and you attempt to configure IPv6 routing features without first selecting the Dual IPv4-IPv6 Routing template, the IPv6 commands do not take effect. IPv6 features are not available when an IPv4-only template is active. Why is the System Time Needed? The switch uses the system clock to provide time stamps on log messages. Additionally, some show commands include the time in the command output. For example, the show users login-history command includes a Login Time field. The system clock provides the information for the Login Time field. How Does SNTP Work? SNTP assures accurate switch clock time synchronization. Time synchronization is performed by a network SNTP server. Time sources are established by Stratums. Stratums define the accuracy of the reference clock. The higher the stratum (where zero is the highest), the more accurate the clock. The switch is at a stratum that is one lower than its time source. For example, if the SNTP server in an internal network is a Stratum 3 device, the switch is a Stratum 4 device. You can configure the switch to request the time from an SNTP server on the network, or you can allow the switch to receive SNTP broadcasts. Requesting the time from a unicast SNTP server is more secure. Use this method if you know the IP address of the SNTP server on your network. If you allow the switch to receive SNTP broadcasts, any clock synchronization information is accepted, even if it has not been requested by the device. This method is less secure than polling a specified SNTP server. Managing General System Settings 283 To increase security, you can require authentication between the configured SNTP server and the SNTP client on the switch. Authentication is provided by Message Digest 5 (MD5). MD5 verifies the integrity of the communication and authenticates the origin of the communication. What Configuration Is Required for Plug-In Modules? The N3000/N4000 series switches support several different plug-in modules (also known as cards) for the expansion slots located on the back of the switch. For information about the slots and the supported modules, see "Hardware Overview" on page 91. You can preconfigure the card type prior to inserting it into the switch. Hot-swap is supported on the N3000/N4000 switch modules. However, the switch must be rebooted for the new module to be recognized after it is inserted. Before inserting a new module into the expansion slot that was previously occupied by a different type of module, issue a no slot command from the CLI so that the switch can recognize the new module. Once a module hs been recognized by the switch, its configuration is stored locally on the switch as the switch default. The module configuration appears in the running-config for informational purposes. 284 Managing General System Settings What Are the Key PoE Plus Features for the N2024P/N2048P and N3024P/N3048P Switches? Table 12-4 describes some of the key PoE Plus features the switches support. Table 12-4. PoE Plus Key Features Feature Description Global Usage Threshold Provides the ability to specify a power limit as a percentage of the maximum power available to PoE ports. Setting a limit prevents the PoE switch from reaching an overload condition. Per-Port Power Prioritization Provides the ability to assign a priority to each PoE port. When the power budget of the PoE switch has been exhausted, the higher-priority ports are given preference over the lower-priority ports. Lower priority ports are automatically stopped from supplying power in order to provide power to higher-priority ports. Per-Port Power Limit Configurable power limit for each PoE-Plus port. Power Management Modes Supports two power-management modes: • Static—Allows you to reserve a guaranteed amount of power for a PoE port. This is useful for powering up devices which draw variable amount of power and provide them an assured power range to operate within. • Dynamic—Power is not reserved for a given port at any point of time. The power available with the PoE switch is calculated by subtracting the instantaneous power drawn by all the ports from the maximum available power. Thus more ports can be powered at the same time. This feature is useful to efficiently power up more number of devices when the available power with the PoE switch is limited Power Detection Mode Allows you to set the mode to legacy or 4-point 802.3AF detection. Enabling an additional high-power setting will allow the detection of 802.1at devices. Managing General System Settings 285 Table 12-4. PoE Plus Key Features (Continued) Feature Description Powered Device (PD) Disconnection Detection Mode Configurable setting to set the method that determines when a PD has disconnected from a port: • AC Disconnect—Assumes that when a valid PD is connected to a port, the AC impedance measured on its terminals is significantly lower than in the case of an open port (disconnected PD) • DC Disconnect—Measures current consumption to determine when a PD stops consuming current. Default General System Information By default, no system information or time information is configured, and the SNTP client is disabled. The default SDM Template applied to the switch is the Dual IPv4-IPv6 template. The following table shows the default PoE Plus settings for the Dell Networking N2024P /N2048P and N3024P/N3048P switches. Table 12-5. PoE Plus Key Features (N2024P, N2048P, N3024P, N3048P Only) Feature Description Global Usage Threshold 0% Per-Port Admin Status Auto Per-Port Power Prioritization Enabled (globally, per-port priority is Low Per-Port Power Limit None Power Management Mode Dynamic Power Detection Mode 802.3af Only Powered Device (PD) Disconnection Detection Mode AC Power Pairs alternative-a 286 Managing General System Settings Configuring General System Settings (Web) This section provides information about the OpenManage Switch Administrator pages for configuring and monitoring general system settings on the Dell Networking N2000, N3000, and N4000 series switches. For details about the fields on a page, click at the top of the page. System Information Use the System Information page to configure the system name, contact name, location, and asset tag. NOTE: From the System Information page, you can also initiate a Telnet session to the switch. To display the System Information page, click System → General → System Information in the navigation panel. Figure 12-1. System Information Managing General System Settings 287 Initiating a Telnet Session from the Web Interface NOTE: The Telnet client feature does not work with Microsoft Windows Internet Explorer 7 and later versions. Initiating this feature from any browser running on a Linux operating system is not supported. To launch a Telnet session: 1 From the System → General → System Information page, click the Telnet link. 2 Click the Telnet button. Figure 12-2. Telnet 3 Select the Telnet client, and click OK. Figure 12-3. Select Telnet Client 288 Managing General System Settings The selected Telnet client launches and connects to the switch CLI. Figure 12-4. Telnet Session Managing General System Settings 289 CLI Banner Use the CLI Banner page to configure a message for the switch to display when a user connects to the switch by using the CLI. You can configure different banners for various CLI modes and access methods. To display the CLI Banner page, click System → General → CLI Banner in the navigation panel. Figure 12-5. CLI Banner 290 Managing General System Settings SDM Template Preference Use the SDM Template Preference page to view information about template resource settings and to select the template that the switch uses. If you select a new SDM template for the switch to use, you must reboot the switch before the template is applied. To display the SDM Template Preference page, click System → General → SDM Template Preference in the navigation panel. Figure 12-6. SDM Template Preference Managing General System Settings 291 Clock If you do not obtain the system time from an SNTP server, you can manually set the date and time on the switch on the Clock page. The Clock page also displays information about the time settings configured on the switch. To display the Clock page, click System → Time Synchronization → Clock in the navigation panel. Figure 12-7. Clock NOTE: The system time cannot be set manually if the SNTP client is enabled. Use the SNTP Global Settings page to enable or disable the SNTP client. 292 Managing General System Settings SNTP Global Settings Use the SNTP Global Settings page to enable or disable the SNTP client, configure whether and how often the client sends SNTP requests, and determine whether the switch can receive SNTP broadcasts. To display the SNTP Global Settings page, click System → Time Synchronization → SNTP Global Settings in the navigation panel. Figure 12-8. SNTP Global Settings Managing General System Settings 293 SNTP Authentication Use the SNTP Authentication page to enable or disable SNTP authentication, to modify the authentication key for a selected encryption key ID, to designate the selected authentication key as a trusted key, and to remove the selected encryption key ID. NOTE: The SNTP server must be configured with the same authentication information to allow time synchronization to take place between the two devices. Click System → Time Synchronization → SNTP Authentication in the navigation panel to display the SNTP Authentication page. Figure 12-9. SNTP Authentication Adding an SNTP Authentication Key To configure SNTP authentication: 1 Open the SNTP Authentication page. 2 Click the Add link. The Add Authentication Key page displays: 294 Managing General System Settings Figure 12-10. Add Authentication Key 3 Enter a numerical encryption key ID and an authentication key in the appropriate fields. 4 If the key is to be used to authenticate a unicast SNTP server, select the Trusted Key check box. If the check box is clear, the key is untrusted and cannot be used for authentication. 5 Click Apply. The SNTP authentication key is added, and the device is updated. To view all configured authentication keys, click the Show All link. The Authentication Key Table displays. You can also use the Authentication Key Table to remove or edit existing keys. Figure 12-11. Authentication Key Table Managing General System Settings 295 SNTP Server Use the SNTP Server page to view and modify information about SNTP servers, and to add new SNTP servers that the switch can use for time synchronization. The switch can accept time information from both IPv4 and IPv6 SNTP servers. To display the SNTP Server page, click System → Time Synchronization → SNTP Server in the navigation panel. If no servers have been configured, the fields in the following image are not displayed. Figure 12-12. SNTP Servers Defining a New SNTP Server To add an SNTP server: 1 Open the SNTP Servers page. 2 Click Add. The Add SNTP Server page displays. 296 Managing General System Settings Figure 12-13. Add SNTP Server 3 In the SNTP Server field, enter the IP address or host name for the new SNTP server. 4 Specify whether the information entered in the SNTP Server field is an IPv4 address, IPv6 address, or a hostname (DNS). 5 If you require authentication between the SNTP client on the switch and the SNTP server, select the Encryption Key ID check box, and then select the key ID to use. To define a new encryption key, see "Adding an SNTP Authentication Key" on page 294. NOTE: The SNTP server must be configured with the same authentication information to allow time synchronization to take place between the two devices. Managing General System Settings 297 To view all configured SNTP servers, click the Show All link. The SNTP Server Table displays. You can also use the SNTP Server Table page to remove or edit existing SNTP servers. Figure 12-14. 298 SNTP Servers Table Managing General System Settings Summer Time Configuration Use the Summer Time Configuration page to configure summer time (daylight saving time) settings. To display the Summer Time Configuration page, click System → Time Synchronization → Summer Time Configuration in the navigation panel. Figure 12-15. Summer Time Configuration NOTE: The fields on the Summer Time Configuration page change when you select or clear the Recurring check box. To use the preconfigured summer time settings for the United States or European Union, select the Recurring check box and specify USA or EU from the Location menu. Managing General System Settings 299 Time Zone Configuration Use the Time Zone Configuration to configure time zone information, including the amount time the local time is offset from UTC and the acronym that represents the local time zone. To display the Time Zone Configuration page, click System → Time Synchronization → Time Zone Configuration in the navigation panel. Figure 12-16. 300 Time Zone Configuration Managing General System Settings Card Configuration Use the Card Configuration page to control the administrative status of the rear-panel expansion slots (Slot 1 or Slot 2) and to configure the plug-in module to use in the slot. To display the Card Configuration page, click Switching → Slots → Card Configuration in the navigation panel. Figure 12-17. Card Configuration Managing General System Settings 301 Slot Summary Use the Slot Summary page to view information about the expansion slot status. To display the Slot Summary page, click Switching → Slots → Summary in the navigation panel. Figure 12-18. 302 Slot Summary Managing General System Settings Supported Cards Use the Supported Cards page to view information about the supported plug-in modules for the switch. To display the Supported Cards page, click Switching → Slots → Supported Cards in the navigation panel. Figure 12-19. Supported Cards Managing General System Settings 303 Power Over Ethernet Global Configuration (N2024P/N2048P and N3024P/N3048P Only) Use the PoE Global Configuration page to configure the PoE settings for the switch. To display the PoE Global Configuration page, click System → General → Power over Ethernet → Global Configuration in the navigation panel. Figure 12-20. 304 PoE Global Configuration Managing General System Settings Power Over Ethernet Interface Configuration (N2024P/N2048P and N3024P/N3048P Only) Use the PoE Interface Configuration page to configure the per-port PoE settings. From this page, you can also access the PoE Counters table and PoE Port Table. The PoE Port table allows you to view and configure PoE settings for multiple ports on the same page. To display the PoE Interface Configuration page, click System → General → Power over Ethernet → Interface Configuration in the navigation panel. Figure 12-21. PoE Interface Configuration Managing General System Settings 305 To view PoE statistics for each port, click Counters. Figure 12-22. PoE Counters Table To view the PoE Port Table, click Show All. Figure 12-23. PoE Port Table If you change any settings for one or more ports on the PoE Port Table page, click Apply to update the switch with the new settings. 306 Managing General System Settings Configuring System Settings (CLI) This section provides information about the commands you use to configure system information and time settings on the Dell Networking N2000, N3000, and N4000 series switches. For more information about these commands, see the Dell Networking N2000, N3000, and N4000 Series Switches CLI Reference Guide at support.dell.com/manuals. Configuring System Information Beginning in Privileged EXEC mode, use the following commands to configure system information. Command Purpose configure Enter Global Configuration mode. hostname name Configure the system name. The CLI prompt changes to the host name after you execute the command. name snmp-server contact Configure the name of the switch administrator. If the name contains a space, use quotation marks around the name. snmp-server location Configure the switch location. tag asset-tag [unit unit_id] Configure the asset tag for the switch. Use the unit keyword to configure the asset tag for each unit in a stack of switches. CTRL + Z Exit to Privileged EXEC mode. show system [id] Display system information. Include the id keyword to display additional system information. location Managing General System Settings 307 Configuring the Banner Beginning in Privileged EXEC mode, use the following commands to configure the MOTD, login, or User EXEC banner. The switch supports the following banner messages: • MOTD—Displays when a user connects to the switch. • Login—Displays after the MOTD banner and before the login prompt. • Exec—Displays immediately after the user logs on to the switch. Command Purpose configure Enter Global Configuration mode. banner Configure the banner message that displays when you {motd|login|exec} text connect to the switch (motd and login) or enter User EXEC mode (exec). Use quotation marks around a message if it includes spaces. line {telnet|ssh|console} Enter the terminal line configuration mode for Telnet, SSH, or the console. motd-banner Specify that the configured MOTD banner displays. To prevent the banner from displaying, enter no motdbanner. exec-banner Specify that the configured exec banner displays. To prevent the banner from displaying, enter no exec-banner. login-banner Specify that the configured login banner displays. To prevent the banner from displaying, enter no login-banner. CTRL + Z Exit to Privileged EXEC mode. show banner Display the banner status on all line terminals. 308 Managing General System Settings Managing the SDM Template Beginning in Privileged EXEC mode, use the following commands to set the SDM template preference and to view information about the available SDM templates. Command Purpose configure Enter Global Configuration mode. sdm prefer {dual-ipv4and-ipv6 default| ipv4routing {data-center | default}} Select the SDM template to apply to the switch after the next boot. CTRL + Z Exit to Privileged EXEC mode. show sdm prefer [template] View information about the SDM template the switch is currently using. Use the template variable to view the parameters for the specified template. Configuring SNTP Authentication and an SNTP Server Beginning in Privileged EXEC mode, use the following commands to require the SNTP client to use authentication when communicating with the SNTP server. The commands also show how to configure an SNTP server. Requiring authentication is optional. However, if you configure authentication on the switch SNTP client, the SNTP server must be configured with the same authentication information to allow time synchronization to take place between the two devices. Command Purpose configure Enter Global Configuration mode. sntp authentication-key Define an authentication key for SNTP. The variables are: key_id md5 key_word • key_id— The encryption key ID, which is a number from 1–4294967295. • key_word—The authentication key, which is a string of up to eight characters. Managing General System Settings 309 Command Purpose sntp trusted-key key_id Specify the authentication key the SNTP server must include in SNTP packets that it sends to the switch. The key_id number must be an encryption key ID defined in the previous step. sntp authenticate Require authentication for communication with the SNTP server. A trusted key must be configured before this command is executed. sntp server {ip_address | Define the SNTP server. hostname} [priority • ip_address—The IP address (or host name) of the SNTP priority] [key key_id] server to poll. The IP address can be an IPv4 or IPv6 address. • priority—(Optional) If multiple SNTP servers are defined, this number determines which server the switch polls first. The priority is 1–8, where 1 is the highest priority. If you do not specify a priority, the servers are polled in the order that they are entered. • key_id—(Optional) Enter an authentication key to use. The key must be previously defined by the sntp authentication-key command. sntp {unicast|broadcast} client enable This command enables the SNTP client and allows the switch to poll configured unicast SNTP servers for updates or receive broadcasts from any SNTP server. sntp client poll timer Specify how often the SNTP client requests SNTP packets from the configured server(s). seconds seconds—The poll interval can be 64, 128, 256, 512, or 1024 seconds. CTRL + Z Exit to Privileged EXEC mode. show sntp configuration Verify the SNTP configuration. show sntp status 310 View information about the SNTP updates. Managing General System Settings Setting the System Time and Date Manually Beginning in Privileged EXEC mode, use the following commands to configure the time and date, time zone, and summer time settings. Command Purpose clock set {mm/dd/yyyy Configure the time and date. You can enter the time first and then the date, or the date and then the time. hh:mm:ss} | {hh:mm:ss • hh:mm:ss —Time in hours (24-hour format, from 01-24), mm/dd/yyyy minutes (00-59), and seconds (00-59). • mm/dd/yyyy — Two digit month (1-12), two-digit date of the month (01-31), and four-digit year. clock timezone hours- Configure the time zone settings. offset hours-offset • hours-offset — Hours difference from UTC. (Range: –12 to [minutes minutes+13) offset] [zone acronym] • minutes-offset — Minutes difference from UTC. (Range: 0–59) • acronym — The acronym for the time zone. (Range: Up to four characters) clock summer-time recurring {usa | eu | {week day month hh:mm week day month hh:mm}} [offset offset] [zone acronym] Use this command if the summer time starts and ends every year based on a set pattern. For switches located in the United States or European Union, use the usa or eu keywords to use the preconfigured values. Otherwise, configure the start and end times by using the following values: • week — Week of the month. (Range: 1–5, first, last) • day — Day of the week. (The first three letters by name) • month — Month. (The first three letters by name; jan, for example.) • hh:mm — Time in 24-hour format in hours and minutes. (Range: hh: 0–23, mm: 0–59) • offset — Number of minutes to add during the summertime. (Range:1–1440) • acronym — The acronym for the time zone to be displayed when summertime is in effect. (Up to four characters) Managing General System Settings 311 Command Purpose clock summer-time date {date month | month date} year hh:mm {date month | month date} year hh:mm [offset offset] [zone acronym] Use this command if the summer time does not start and end every year according to a recurring pattern. You can enter the month and then the date, or the date and then the month. • date— Day of the month. (Range: 1-31.) • month — Month. (Range: The first three letters by name) • hh:mm — Time in 24-hour format in hours and minutes. (Range: hh: 0–23, mm: 0–59) • offset — Number of minutes to add during the summertime. (Range:1–1440) • acronym — The acronym for the time zone to be displayed when summertime is in effect. (Range: Up to four characters) CTRL + Z Exit to Privileged EXEC mode. show clock [detail] View information about the time. Include the detail keyword to view information about the time zone and summer time. Configuring the Expansion Slots (N3000 Series Only) Beginning in Privileged EXEC mode, use the following commands to configure and view information about the expansion slots and plug-in modules (cards). Command Purpose configure Enter Global Configuration mode. slot unit/slot cardindex Configured the specified slot (1–2) to use the plug-in module identified by the cardindex number (CID). To view the CID associated with each plug-in module, use the show supported cardtype command. CTRL + Z Exit to Privileged EXEC mode. show slot Display status information about the expansion slots. show supported cardtype Display information about the plug-in modules the switch supports. 312 Managing General System Settings Viewing Slot Information (N4000 Series Only) Use the following commands to view information about Slot 0 and its support. Command Purpose show slot Display status information about the expansion slots. show supported cardtype Display information about the modules the switch supports. Configuring PoE Settings (N2024P/N2048P and N3024P/N3048P Only) Beginning in Privileged EXEC mode, use the following commands to configure PoE information. Command Purpose configure Enter Global Configuration mode. power inline usagethreshold threshold Specify the maximum usage for PoE power on the system. The threshold variable (range: 1–99%) is a percentage of total system power. power inline management {class | static | dynamic} Set the power-management mode for the switch. power inline detection {dot3af | dot3af+legacy} Set the power-management mode for the switch. interface interface Enter interface configuration mode for the specified port. The interface variable includes the interface type and number, for example gigabitethernet 1/0/3. power inline {auto | never} Set the PoE device discovery admin mode. • 802.3af-only—IEEE 802.3af detection scheme is used. • 802.3af+legacy—IEEE 802.3af 4point detection scheme is used and when it fails to detect a connected PD, legacy capacitive detection is used. • auto — Enables the device discovery protocol and, if found, supplies power to the device. • never — Disables the device discovery protocol and stops supplying power to the device. Managing General System Settings 313 Command Purpose power inline priority {critical | high | low} Configures the port priority level for the delivery of power to an attached device. power inline high-power Configure the port high power mode for connected-device compatibility. power inline limit user-defined limit Set the per-port power limit. power inline powereddevice type Provide a description to represent the type of device connected to the port. power inline reset (Optional) Reset the port. You might use this command if the port is stuck in an Error state. CTRL + Z Exit to Privileged EXEC mode. show power inline Display PoE information for the switch. show power inline Display PoE information for the specified interface. interface 314 • user-defined limit—Allows the port to draw up to user defined configured value. The range of limit is 3000–32000 milliwatts. Managing General System Settings General System Settings Configuration Examples This section contains the following examples: • Configuring System and Banner Information • Configuring SNTP • Configuring the Time Manually Configuring System and Banner Information In this example, an administrator configures the following system information: • System name: N2048 • System contact: Jane Doe • System location: RTP100 • Asset tag: 006429 The administrator then configures the MOTD banner to alert other switch administrators of the connected topology. To configure the switch: 1 Configure the hosts name. console#configure console(config)#hostname N2048 2 Configure the contact, location, and asset tag. Notice that the prompt changed to the host name. N2048(config)#snmp-server contact “Jane Doe” N2048(config)#snmp-server location RTP100 N2048(config)#asset-tag 006429 3 Configure the message that displays when a user connects to the switch. N2048(config)#banner motd “This switch connects users in cubicles C121-C139.” N2048(config)#exit 4 View system information to verify the configuration. N2048#show system System Description: Dell Ethernet Switch System Up Time: 0 days, 19h:36m:36s Managing General System Settings 315 System Contact: Jane Doe System Name: N2048 System Location: RTP100 Burned In MAC Address: 001E.C9AA.AA07 System Object ID: 1.3.6.1.4.1.674.10895.3035 System Model ID: N2048 Machine Type: Dell Networking N2048 Temperature Sensors: Unit Temperature (Celsius) Status ----------------------------1 43 OK Power Supplies: Unit Description Status Source ----------------------------1 Main OK AC 1 Secondary Error DC Temperature Sensors: Unit Description ---1 1 1 1 ----------CPU MAC Left PHY Right PHY Temperature (Celsius) ----------33 39 32 33 Fans: Unit ---1 1 1 316 Description ----------Fan 1 Fan 2 Fan 3 Status -----OK OK OK Managing General System Settings Status -----Good Good Good Good Power Supplies: Unit Description ---- ---------1 System 1 Main 1 Secondary Status -------OK Failure OK Average Current Since Power Power Date/Time (Watts) (Watts) ---------- -------- -----------5.0 97.8 97.6 97.8 01/10/2031 15:59:05 5 View additional information about the system. N2048#show system id Service Tag: Chassis Service Tag: N/A Serial Number: 7048NX1011 Asset Tag: unit-1 Unit Service tag Chassis Serv tag ---- ----------- ---------------1 N/A Serial number ------------70498NX1011 Asset tag --------unit-1 Service Tag: 0000000 Chassis Service Tag: Serial Number: TW282987BK0002 Asset Tag: 111222 Unit Service tag Chassis Serv tag Serial number Asset tag ---- ------------ ---------------- ------------- ---------1 0000000 TW282987BK0002 111222 6 Initiate a new Telnet session to verify the MOTD. Managing General System Settings 317 Figure 12-24. 318 Verify MOTD Managing General System Settings Configuring SNTP The commands in this example configure the switch to poll an SNTP server to synchronize the time. Additionally, the SNTP sessions between the client and server must be authenticated. To configure the switch: 1 Configure the authentication information. The SNTP server must be configured with the same authentication key and ID. console#configure console(config)#sntp authentication-key 23456465 md5 sntpkey console(config)#sntp trusted-key 23456465 console(config)#sntp authenticate 2 Specify the IP address of the SNTP server to poll and include the authentication key. This command automatically enables polling and sets the priority to 1. console(config)#sntp server 192.168.10.30 key 23456465 console(config)#sntp unicast client enable 3 Verify the configuration. console#show sntp configuration Polling interval: 512 seconds MD5 Authentication keys: 23456465 Authentication is required for synchronization. Trusted keys: 23456465 Unicast clients: Enable Unicast servers: Server Key Polling Priority ---------------------- --------- -------192.168.10.30 23456465 Enabled 1 Managing General System Settings 319 4 View the SNTP status on the switch. console#show sntp status Client Mode: Last Update Time: Unicast MAR 01 09:12:43 2010 Unicast servers: Server Status Last response --------------- ------------ --------------------192.168.10.30 Other 09:12:43 Mar 1 2011 320 Managing General System Settings Configuring the Time Manually The commands in this example manually set the system time and date. The time zone is set to Eastern Standard Time (EST), which has an offset of -5 hours. Summer time is enabled and uses the preconfigured United States settings. To configure the switch: 1 Configure the time zone offset and acronym. console#configure console(config)#clock timezone -5 zone EST 2 Configure the summer time (daylight saving time) to use the preconfigured settings for the United States. console(config)#clock summer-time recurring us 3 Set the local time and date. console(config)#clock set 16:13.06 03/01/2010 4 Verify the time settings. console#show clock detail 00:27:19 EST(UTC-5:00) Feb 3 2039 No time source Time zone: Acronym is EST Offset is UTC-5:00 Summertime: Acronym not configured Recurring every year (USA) Begins on second Sunday of Mar at 02:00 Ends on first Sunday of Nov at 02:00 Offset is +60 minutes Managing General System Settings 321 322 Managing General System Settings Configuring SNMP 13 The topics covered in this chapter include: • SNMP Overview • Default SNMP Values • Configuring SNMP (Web) • Configuring SNMP (CLI) • SNMP Configuration Examples SNMP Overview Simple Network Management Protocol (SNMP) provides a method for managing network devices. The Dell Networking series switches support SNMP version 1, SNMP version 2, and SNMP version 3. What Is SNMP? SNMP is a standard protocol that enables remote monitoring and management of a device through communication between an SNMP manager and an SNMP agent on the remote device. The SNMP manager is typically part of a Network Management System (NMS) that runs on an administrative host. The switch software includes Management Information Base (MIB) objects that the SNMP agent queries and modifies. The switch uses standard public MIBs and private MIBs. A MIB acts as a structured road map for managed objects. A managed object is any feature or setting that can be configured or monitored on the switch. An Object Identifier (OID) is the unique number assigned to an object defined in a MIB. An OID is written as a sequence of subidentifiers in decimal notation. Configuring SNMP 323 The SNMP agent maintains a list of variables that are used to manage the switch. The variables are defined in the MIB. The MIB presents the variables controlled by the agent. The SNMP agent defines the MIB specification format, as well as the format used to access the information over the network. Access rights to the SNMP agent are controlled by access strings. SNMP v3 also applies access control and a new traps mechanism to SNMPv1 and SNMPv2 PDUs. In addition, the User Security Model (USM) is defined for SNMPv3 and includes: • Authentication — Provides data integrity and data origin authentication. • Privacy — Protects against disclosure of message content. Cipher-BockChaining (CBC) is used for encryption. Either authentication is enabled on an SNMP message, or both authentication and privacy are enabled on an SNMP message. However privacy cannot be enabled without authentication. • Timeliness — Protects against message delay or message redundancy. The SNMP agent compares incoming message to the message time information. • Key Management — Defines key generation, key updates, and key use. Authentication or Privacy Keys are modified in the SNMPv3 User Security Model (USM). What Are SNMP Traps? SNMP is frequently used to monitor systems for fault conditions such as temperature violations, link failures, and so on. Management applications can monitor for these conditions by polling the appropriate OIDs with the get command and analyzing the returned data. This method has its drawbacks. If it is done frequently, significant amounts of network bandwidth can be consumed. If it is done infrequently, the response to the fault condition may not occur in a timely fashion. SNMP traps avoid these limitations of the polling method. An SNMP trap is an asynchronous event indicating that something significant has occurred. This is analogous to a pager receiving an important message, except that he SNMP trap frequently contains all the information needed to diagnose a fault. 324 Configuring SNMP You can configure various features on the switch to generate SNMP traps that inform the NMS about events or problems that occur on the switch. Traps generated by the switch can also be viewed locally by using the web-based interface or CLI. Why Is SNMP Needed? Some network administrators prefer to use SNMP as the switch management interface. Settings that you view and configure by using the web-based Dell OpenManage Switch Administrator and the CLI are also available by using SNMP. If you do not use NMS software to manage or monitor other devices on your network, it might not be necessary to configure SNMP on the switch. Default SNMP Values By default, SNMPv2 is automatically enabled on the device. SNMPv1 and SNMPv3 are disabled. To enable SNMPv3, you must define a local engine ID for the device. The local engineID is by default set to the switch MAC address, however when the switch operates in a stacking mode, it is important to manually configure the local engineID for the stack. This local engineID must be defined so that it is unique within the network. It is important to do this because the default engineID in a stack is the MAC address of the master unit, which may change if the master unit fails and another unit takes over the stack. Table 13-1 summarizes the default values for SNMP. Table 13-1. SNMP Defaults Parameter Default Value SNMPv1 Disabled SNMPv2 Enabled SNMPv3 Disabled SNMP traps Enabled SNMP trap receiver None configured Switch traps Enabled Configuring SNMP 325 Table 13-1. SNMP Defaults Parameter Default Value QoS traps Enabled Multicast traps Disabled Captive Portal traps Disabled OSPF traps Disabled Table 13-2 describes the two views that are defined by default. Table 13-2. SNMP Default Views View Name OID Subtree View Type Default iso Included snmpVacmMIB Excluded usmUser Excluded snmpCommunityTable Excluded iso Included DefaultSuper By default, three groups are defined. Table 13-3 describes the groups. The Read, Write, and Notify values define the preconfigured views that are associated with the groups. Table 13-3. SNMP Default Groups Group Name Security Level Read Write Notify DefaultRead No Auth No Priv Default – Default DefaultWrite No Auth No Priv Default Default Default DefaultSuper No Auth No Priv DefaultSuper DefaultSuper DefaultSuper 326 Configuring SNMP Configuring SNMP (Web) This section provides information about the OpenManage Switch Administrator pages for configuring and monitoring the SNMP agent on a Dell Networking N2000, N3000, and N4000 series switches. For details about the fields on a page, click at the top of the page. NOTE: For some features, the control to enable or disable traps is available from a configuration page for that feature and not from the Trap Manager pages that this chapter describes. SNMP Global Parameters Use the Global Parameters page to enable SNMP and Authentication notifications. To display the Global Parameters page, click System → SNMP → Global Parameters in the navigation panel. Figure 13-1. SNMP Global Parameters Configuring SNMP 327 SNMP View Settings Use the SNMP View Settings page to create views that define which features of the device are accessible and which are blocked. You can create a view that includes or excludes OIDs corresponding to interfaces. To display the View Settings page, click System → SNMP → View Settings in the navigation panel. Figure 13-2. SNMP View Settings Adding an SNMP View To add a view: 1 Open the View Settings page. 2 Click Add. The Add View page displays: 328 Configuring SNMP Figure 13-3. Add View 3 Specify a name for the view and a valid SNMP OID string. 4 Select the view type. 5 Click Apply. The SNMP view is added, and the device is updated. Click Show All to view information about configured SNMP Views. Configuring SNMP 329 Access Control Group Use the Access Control Group page to view information for creating SNMP groups, and to assign SNMP access privileges. Groups allow network managers to assign access rights to specific device features or features aspects. To display the Access Control Group page, click System → SNMP → Access Control in the navigation panel. Figure 13-4. SNMP Access Control Group Adding an SNMP Group To add a group: 1 Open the Access Control Configuration page. 2 Click Add. The Add an Access Control Configuration page displays: 330 Configuring SNMP Figure 13-5. Add Access Control Group 3 Specify a name for the group. 4 Select a security model and level 5 Define the context prefix and the operation. 6 Click Apply to update the switch. Click Show All to view information about existing access control configurations. Configuring SNMP 331 SNMPv3 User Security Model (USM) Use the User Security Model page to assign system users to SNMP groups and to define the user authentication method. NOTE: You can also use the Local User Database page under Management Security to configure SNMPv3 settings for users. For more information, see "Configuring Authentication, Authorization, and Accounting" on page 207. To display the User Security Model page, click System → SNMP → User Security Model in the navigation panel. Figure 13-6. SNMPv3 User Security Model Adding Local SNMPv3 Users to a USM To add local users: 1 Open the User Security Model page. 2 Click Add Local User. The Add Local User page displays: 332 Configuring SNMP Figure 13-7. Add Local Users 3 Define the relevant fields. 4 Click Apply to update the switch. Click Show All to view the User Security Model Table, which contains information about configured Local and Remote Users. Adding Remote SNMPv3 Users to a USM To add remote users: 1 Open the SNMPv3 User Security Model page. 2 Click Add Remote User. The Add Remote User page displays: Configuring SNMP 333 Figure 13-8. Add Remote Users 3 Define the relevant fields. 4 Click Apply to update the switch. Click Show All to view the User Security Model Table, which contains information about configured Local and Remote Users. 334 Configuring SNMP Communities Access rights for SNMPv1 and SNMPv2 are managed by defining communities Communities page. When the community names are changed, access rights are also changed. SNMP Communities are defined only for SNMP v1 and SNMP v2. To display the Communities page, click System → SNMP → Communities in the navigation panel. Figure 13-9. SNMP Communities Adding SNMP Communities To add a community: 1 Open the Communities page. 2 Click Add. The Add SNMPv1,2 Community page displays: Configuring SNMP 335 Figure 13-10. Add SNMPv1,2 Community 3 Specify the IP address of an SNMP management station and the community string to act as a password that will authenticate the management station to the SNMP agent on the switch. 4 Select the access mode. 5 Click Apply to update the switch. Click Show All to view the communities that have already been configured. 336 Configuring SNMP Notification Filter Use the Notification Filter page to set filtering traps based on OIDs. Each OID is linked to a device feature or a feature aspect. The Notification Filter page also allows you to filter notifications. To display the Notification Filter page, click System → SNMP → Notification Filters in the navigation panel. Figure 13-11. SNMP Notification Filter Adding a Notification Filter To add a filter: 1 Open the Notification Filter page. 2 Click Add. The Add Filter page displays: Configuring SNMP 337 Figure 13-12. Add Notification Filter 3 Specify the name of the filter, the OID for the filter. 4 Choose whether to send (include) traps or informs to the trap recipient or prevent the switch from sending (exclude) the traps or informs. 5 Click Apply to update the switch. Click Show All to view information about the filters that have already been configured. Notification Recipients Use the Notification Recipients page to view information for defining filters that determine whether traps are sent to specific users, and the trap type sent. SNMP notification filters provide the following services: • Identifying Management Trap Targets • Trap Filtering • Selecting Trap Generation Parameters • Providing Access Control Checks To display the Notification Recipients page, click System → SNMP → Notification Recipient in the navigation panel. 338 Configuring SNMP Figure 13-13. SNMP Notification Recipient Adding a Notification Recipient To add a recipient: 1 Open the Notification Recipient page. 2 Click Add. The Add Recipient page displays: Configuring SNMP 339 Figure 13-14. Add Notification Recipient 3 Specify the IP address or hostname of the host to receive notifications. 4 Select whether to send traps or informs to the specified recipient 5 Define the relevant fields for the SNMP version you use. 6 Configure information about the port on the recipient. 7 Click Apply to update the switch. Click Show All to view information about the recipients that have already been configured. Trap Flags The Trap Flags page is used to specify which traps you want to enable or disable. When the condition identified by an active trap is encountered by the switch, a trap message is sent to any enabled SNMP Trap Receivers, and a message is written to the trap log. 340 Configuring SNMP To access the Trap Flags page, click Statistics/RMON → Trap Manager → Trap Flags in the navigation panel. Figure 13-15. Trap Flags OSPFv2 Trap Flags The OSPFv2 Trap Flags page is used to specify which OSPFv2 traps you want to enable or disable. When the condition identified by an active trap is encountered by the switch, a trap message is sent to any enabled SNMP Trap Receivers, and a message is written to the trap log. To access the OSPFv2 Trap Flags page, click Statistics/RMON → Trap Manager → OSPFv2 Trap Flags in the navigation panel. Configuring SNMP 341 Figure 13-16. OSPFv2 Trap Flags OSPFv3 Trap Flags The OSPFv3 Trap Flags page is used to specify which OSPFv3 traps you want to enable or disable. When the condition identified by an active trap is encountered by the switch, a trap message is sent to any enabled SNMP Trap Receivers, and a message is written to the trap log. To access the OSPFv3 Trap Flags page, click Statistics/RMON → Trap Manager → OSPFv3 Trap Flags in the navigation panel. 342 Configuring SNMP Figure 13-17. OSPFv3 Trap Flags Trap Log The Trap Log page is used to view entries that have been written to the trap log. To access the Trap Log page, click Statistics/RMON → Trap Manager → Trap Log in the navigation panel. Configuring SNMP 343 Figure 13-18. Trap Logs Click Clear to delete all entries from the trap log. 344 Configuring SNMP Configuring SNMP (CLI) This section provides information about the commands you use to manage and view SNMP features on the switch. For more information about these commands, see the Dell Networking N2000, N3000, and N4000 Series Switches CLI Reference Guide at support.dell.com/manuals. Configuring the SNMPv3 Engine ID To use SNMPv3, the switch must have engine ID. You can specify your own ID or use the default string that is generated using the MAC address of the switch. If the SNMPv3 engine ID is deleted, or if the configuration file is erased, then SNMPv3 cannot be used. Since the EngineID should be unique within an administrative domain, Dell recommends that you use the default keyword to configure the Engine ID. the following guidelines are recommended: • For standalone switches use the default keyword to configure the Engine ID. • For a stack of switches, configure your own EngineID, and verify that is unique within your administrative domain. Changing the value of SNMP EngineID has important side-effects. A user's password (entered on the command line) is converted to an MD5 or SHA security digest. This digest is based on both the password and the local engine ID. The command line password is then destroyed, as required by RFC 2274. Because of this deletion, if the local value of engineID changes, the security digests of SNMPv3 users will be invalid, and the users will have to be reconfigured. Beginning in Privileged EXEC mode, use the following commands to configure an engine ID for SNMP. Command Purpose configure Enter Global Configuration mode Configuring SNMP 345 Command Purpose snmp-server engineID local {engineid-string | default} Configure the SNMPv3 Engine ID. • engineid-string — The character string that identifies the engine ID. The engine ID is a concatenated hexadecimal string. Each byte in hexadecimal character strings is two hexadecimal digits. Each byte can be separated by a period or colon. (Range: 6-32 characters) • default — The engineID is created automatically, based on the device MAC address. exit Exit to Privileged EXEC mode. show snmp engineid View the local SNMP engine ID. Configuring SNMP Views, Groups, and Users Beginning in Privileged EXEC mode, use the following commands to define SNMP views, and SNMP groups, and local and remote SNMPv3 users. Command Purpose configure Enter Global Configuration mode snmp-server view view- Configure the SNMP view. When you configure groups, name oid-tree {included users, and communities, you can specify a view to associate | excluded} with the group, user, or community • view-name — Specifies the name of the view. (Range: 130 characters.) • oid-tree — Specifies the object identifier of the ASN.1 subtree to be included or excluded from the view. To identify the subtree, specify a text string consisting of numbers, such as 1.3.6.2.4, or a word, such as system. Replace a single subidentifier with the asterisk (*) wildcard to specify a subtree family; for example 1.3.*.4. • included — Indicates that the view type is included. • excluded — Indicates that the view type is excluded. 346 Configuring SNMP Command Purpose snmp-server group groupname {v1 | v2 | v3 {noauth | auth | priv} [notify view-name]} [context view-name] [read view-name] [write view-name] Specify the identity string of the receiver and set the receiver timeout value. • groupname — Specifies the name of the group. (Range: 1-30 characters.) • v1 — Indicates the SNMP Version 1 security model. • v2 — Indicates the SNMP Version 2 security model. • v3 — Indicates the SNMP Version 3 security model. • noauth — Indicates no authentication of a packet. Applicable only to the SNMP Version 3 security model. • auth — Indicates authentication of a packet without encrypting it. Applicable only to the SNMP Version 3 security model. • priv — Indicates authentication of a packet with encryption. Applicable only to the SNMP Version 3 security model. • view-name — Specifies the view (defined in the previous step) to use for the context, notification, read, and write privileges for the group. Configuring SNMP 347 Command Purpose snmp-server user Configure a new SNMPv3 user. username groupname • username — Specifies the name of the user on the host [remote engineid-string] that connects to the agent. (Range: 1-30 characters.) [{auth-md5 password | • groupname — Specifies the name of the group to which auth-sha password | the user belongs. (Range: 1-30 characters.) auth-md5-key md5-key | auth-sha-key sha-key} • engineid-string — Specifies the engine ID of the remote [priv-des password | SNMP entity to which the user belongs. The engine ID is priv-des-key des-key]] a concatenated hexadecimal string. Each byte in the hexadecimal character string is two hexadecimal digits. The remote engine id designates the remote management station, and should be defined to enable the device to receive acknowledgements to "informs." (Range: 5-32 characters.) • auth-md5 — The HMAC-MD5-96 authentication level. • auth-sha — The HMAC-SHA-96 authentication level. • password — A password. (Range: 1 to 32 characters.) • auth-md5-key — The HMAC-MD5-96 authentication level. Enter a pregenerated MD5 key. • auth-sha-key — The HMAC-SHA-96 authentication level. Enter a pregenerated SHA key. • md5-key — Character string—length 32 hex characters. • sha-key — Character string—length 48 characters. • priv-des — The CBC-DES Symmetric Encryption privacy level. Enter a password. • priv-des-key — The CBC-DES Symmetric Encryption privacy level. The user should enter a pregenerated MD5 or SHA key depending on the authentication level selected. • des-key — The pregenerated DES encryption key. Length is determined by authentication method selected—32 hex characters if MD5 Authentication is selected, 48 hex characters if SHA Authentication is selected. exit Exit to Privileged EXEC mode. show snmp views View SNMP view configuration information. 348 Configuring SNMP Command Purpose show snmp group [group_name] View SNMP group configuration information. show snmp user [user_name] View SNMP user configuration information. Configuring Communities Beginning in Privileged EXEC mode, use the following commands to configure access rights for SNMPv1 and SNMPv2. Command Purpose configure Enter Global Configuration mode snmp-server community Configure the community string and specify access criteria string [ro | rw | su] for the community. [view view-name] • community-string — Acts as a password and is used to [ipaddress ip_address] authenticate the SNMP management station to the switch. The string must also be defined on the NMS in order for the NMS to access the SNMP agent on the switch (Range: 1-20 characters) • ro — Indicates read-only access • rw — Indicates read-write access. • view-name — Specifies the name of a previously defined MIB view. • ip_address — Specifies the IP address of the management station. If no IP address is specified, all management stations are permitted Configuring SNMP 349 Command Purpose snmp-server community- Map the internal security name for SNMP v1 and SNMP group community-string v2 security models to the group name. group-name [ipaddress • community-string — Community string that acts like a ip-address] password and permits access to the SNMP protocol. (Range: 1-20 characters) • group-name — Name of a previously defined group. The group defines the objects available to the community. (Range: 1-30 characters) • ip-address — Management station IP address. Default is all IP addresses. exit Exit to Privileged EXEC mode. show snmp View SNMP settings and verify the configuration 350 Configuring SNMP Configuring SNMP Notifications (Traps and Informs) Beginning in Privileged EXEC mode, use the following commands to allow the switch to send SNMP traps and to configure which traps are sent. Command Purpose configure Enter Global Configuration mode snmp-server enable traps [acl | all | auto-copy-sw | captive-portal cp-type | dot1q | dvrmp | link | maclock | multipleusers | ospf ospftype | ospfv3 ospfv3type | pim | poe | snmp authentication | spanning-tree | stack | vrrp] Specify the traps to enable. The captive portal, OSPF and OSPFv3 traps include several different traps that can be enabled. For more information, use the CLI command help or see the CLI Command Reference. snmp-server filter filter- Configure a filter for SNMP traps and informs based on name oid-tree {included OIDs. Each OID is linked to a device feature or a feature | excluded} aspect. • filter-name — Specifies the label for the filter record that is being updated or created. The name is used to reference the record. (Range: 1-30 characters.) • oid-tree — Specifies the object identifier of the ASN.1 subtree to be included or excluded from the view. To identify the subtree, specify a text string consisting of numbers, such as 1.3.6.2.4, or a word, such as system. Replace a single subidentifier with the asterisk (*) wildcard to specify a subtree family; for example, 1.3.*.4. • included — Indicates that the filter type is included. • excluded — Indicates that the filter type is excluded. Configuring SNMP 351 Command Purpose snmp-server host host- For SNMPv1 and SNMPv2, configure the system to receive addr [informs [timeout SNMP traps or informs. seconds] [retries retries] • host-addr — Specifies the IP address of the host (targeted | traps version {1 | 2}]] recipient) or the name of the host. (Range:1-158 community-string [udpcharacters). port port] [filter • informs — Indicates that SNMPv2 informs are sent to filtername] this host • timeout seconds — Number of seconds to wait for an acknowledgment before resending informs. The default is 15 seconds. (Range: 1-300 characters.) • retries — Maximum number of times to resend an inform request. The default is 3 attempts. • traps — Indicates that SNMP traps are sent to this host – version 1 — Indicates that SNMPv1 traps will be used – version 2 — Indicates that SNMPv2 traps will be used • community-string — Specifies a password-like community string sent with the notification operation. (Range: 1-20 characters) • port — UDP port of the host to use. The default is 162. (Range: 1-65535 characters.) • filtername — A string that is the name of the filter that defines the filter for this host. If unspecified, does not filter anything (Range: 1-30 characters.) 352 Configuring SNMP Command Purpose snmp-server v3-host {ip- For SNMPv3, configure the system to receive SNMP traps or informs. address | hostname} username {traps | • ip-address — Specifies the IP address of the host informs} [noauth | auth (targeted recipient). | priv] [timeout • hostname — Specifies the name of the host. (Range: 1seconds] [retries retries] 158 characters.) [udpport port] [filter filtername] • username — Specifies user name used to generate the notification. (Range: 1-25 characters.) • traps — Indicates that SNMP traps are sent to this host. • informs — Indicates that SNMPv2 informs are sent to this host. • noauth — Specifies sending of a packet without authentication. • auth — Specifies authentication of a packet without encrypting it • priv — Specifies authentication and encryption of a packet. • seconds — Number of seconds to wait for an acknowledgment before resending informs. This is not allowed for hosts configured to send traps. The default is 15 seconds. (Range: 1-300 seconds.) • retries — Maximum number of times to resend an inform request. This is not allowed for hosts configured to send traps. The default is 3 attempts. (Range: 0-255 retries.) • port — UDP port of the host to use. The default is 162. (Range: 1-65535.) • filter-name — Specifies the optional filter (defined with the snmp-server filter command) to use for the host. (Range: 1-30 characters.) exit Exit to Privileged EXEC mode. show trapflags View the status of the configurable SNMP traps. Configuring SNMP 353 SNMP Configuration Examples This section contains the following examples: • Configuring SNMPv1 and SNMPv2 • Configuring SNMPv3 Configuring SNMPv1 and SNMPv2 This example shows how to complete a basic SNMPv1/v2 configuration. The commands enable read-only access from any host to all objects on the switch using the community string public, and enable read-write access from any host to all objects on the switch using the community string private. This example also shows how to allow the switch to generate traps for all features that produce traps. The traps are sent to the host with an IP address of 192.168.3.65 using the community string public. To configure the switch: 1 Configure the public community string. console#configure console(config)#snmp-server community public ro 2 Configure the private community string. console(config)#snmp-server community private rw 3 Enable all traps and specify the IP address of the host where the traps should be sent. console(config)#snmp-server enable traps all console(config)#snmp-server host 192.168.3.65 public console(config)#exit 4 View the current SNMP configuration on the switch. console#show snmp Community-String -------------------private public 354 Configuring SNMP Community-Access ---------------Read/Write Read Only View Name IP Address --------- ------Default All Default All Community-String ----------------private public Group Name -------------DefaultWrite DefaultRead IP Address -----------All All Traps are enabled. Authentication trap is enabled. Version 1,2 notifications Target Addr. Type Community Version UDP Filter TO Port Name Sec ------------ ---- --------- -------- ----- --192.168.3.65 Trap public 1 162 Version 3 notifications Target Addr. Type Username Security UDP Filter TO Level Port Name Sec ------------ ---- --------- ------- ----- ----- --- Retries ------- Retries ------- System Contact: System Location: Configuring SNMPv3 This example shows how to complete a basic SNMPv3 configuration. The commands create a view that includes objects from the internet MIB subtree (OID 1.3.6.1), which includes all objects on the switch. The user named admin has read-write privileges to all objects within the view (in other words, all objects on the switch) after supplying the appropriate authentication credentials (secretkey). To configure the switch: 1 Configure the view. view_snmpv3 and specify the objects to include. console#configure console(config)#snmp-server view view_snmpv3 internet included 2 Create the group group_snmpv3 and allow read-write access to the view configured in the previous step. console(config)#snmp-server group group_snmpv3 v3 auth read view_snmpv3 write view_snmpv3 Configuring SNMP 355 3 Create the user admin, assign the user to the group, and specify the authentication credentials. console(config)#snmp-server user admin group_snmpv3 auth-md5 secretkey 4 Specify the IP address of the host where traps are to be sent. Packet authentication using MD5-SHA is enabled for the traps. console(config)#snmp-server v3-host 192.168.3.35 admin traps auth console(config)#exit 5 View the current SNMP configuration on the switch. The output includes the SNMPv1/2 configuration in the previous example. console#show snmp Community-String -------------------private public Community-Access ---------------Read/Write Read Only Community-String ----------------private public Group Name -------------DefaultWrite DefaultRead View Name IP Address --------- ------Default All Default All IP Address -----------All All Traps are enabled. Authentication trap is enabled. Version 1,2 notifications Target Addr. Type Community Version UDP Filter TO Port Name Sec ------------ ---- --------- -------- ----- --192.168.3.65 Trap public 1 162 Version 3 notifications Target Addr. Type Username Security Level ------------ ---- --------- ------192.168.3.35 Trap admin Auth-NoP System Contact: System Location: 356 Configuring SNMP UDP Filter TO Port Name Sec ----- ----- --162 15 Retries ------- Retries ------3 console#show snmp views Name -----------------Default Default Default Default view_snmpv3 DefaultSuper OID Tree -----------------------iso snmpVacmMIB usmUser snmpCommunityTable internet iso Type -----------Included Excluded Excluded Excluded Included Included console#show snmp group Name Context Model Prefix ------------ -------- -----DefaultRead "" V1 DefaultRead "" V2 DefaultSuper "" V1 DefaultSuper "" V2 DefaultWrite "" V1 DefaultWrite "" V2 group_snmpv3 "" V3 Security Level -------NoAuthNoPriv NoAuthNoPriv NoAuthNoPriv NoAuthNoPriv NoAuthNoPriv NoAuthNoPriv AuthNoPriv Read Views Write -------- -----Default "" Notify Default Default "" DefaultSuDefault per Super DefaultSuDefault per Super Default Default Default ------Default Default Super Default Super Default Default Default view_snmpview_sn "" v3 mpv3 console#show snmp user Name Group Name --------admin ----------group_snmpv3 Auth Meth ----MD5 Priv Meth ----- Remote Engine ID ---------------800002a203001ec9aaaa07 Configuring SNMP 357 358 Configuring SNMP Managing Images and Files 14 This chapter describes how to upload, download, and copy files, such as firmware images and configuration files, on the switch. The topics covered in this chapter include: • Image and File Management Overview • Managing Images and Files (Web) • Managing Images and Files (CLI) • File and Image Management Configuration Examples NOTE: For information about the Auto Configuration feature that enables the switch to automatically upgrade the image or load a new configuration file during the boot process, see Automatically Updating the Image and Configuration. Image and File Management Overview What Files Can Be Managed? Dell Networking series switches maintain several different types of files on the flash file system. Table 14-1 describes the files that you can manage. The table also lists the type of action you can take on the file, which is one or more of the following: • Download the file to the switch from a remote system (or USB flash drive). • Upload the file from the switch to a remote system (or USB flash drive). • Copy the file from one location on the file system to another location. Managing Images and Files 359 Table 14-1. Files to Manage File Action Description image Download Upload Copy Firmware for the switch. The switch can maintain two images: the active image and the backup image. startup-config Download Upload Copy Contains the software configuration that loads during the boot process. running-config Download Upload Copy Contains the current switch configuration. backup-config Download Upload Copy An additional configuration file that serves as a backup. Configuration script Download Upload Text file with CLI commands. When you activate a script on the switch, the commands are executed and added to the running-config. Log files Upload Provides various information about events that occur on the switch. For more information, see Monitoring and Logging System Information. SSH key files Download Contains information to authenticate SSH sessions. The switch supports the following files for SSH: • SSH-1 RSA Key File • SSH-2 RSA Key File (PEM Encoded) • SSH-2 Digital Signature Algorithm (DSA) Key File (PEM Encoded) 360 Managing Images and Files Table 14-1. Files to Manage File Action Description SSL certificate files Download Contains information to encrypt, authenticate, and validate HTTPS sessions. The switch supports the following files for SSL: • SSL Trusted Root Certificate File (PEM Encoded) • SSL Server Certificate File (PEM Encoded) • SSL Diffie-Hellman Weak Encryption Parameter File (PEM Encoded) • SSL Diffie-Hellman Strong Encryption Parameter File (PEM Encoded) IAS Users Download List of Internal Authentication Server (IAS) users for IEEE 802.1X authentication. For more information, see What is the Internal Authentication Server? Why Is File Management Needed? This section provides some reasons why you might choose to manage various files. Image Files The switch can store two firmware images, but only one is active. The other image file is a backup image. By default, the switch has only one image. You might copy an image or download an image to the switch for the following reasons: • To create a backup image • To upgrade the firmware as new images become available The Dell Networking series switches are named as follows: v.stk Where the switch name is: N4000 — Dell Networking 4000 series switch firmware for: Managing Images and Files 361 • N4032, N4032F, N4064, N4064F N3000_N2000 — Dell Networking 2000/3000 series switch firmware for: • N2024, N2048, N2024P, N2048P, N3024, N3024P, N3024F, N3048, N3048P And the version number is: Version Numbering Convention Version number 6 0 0 Description 1 Four part version number Denotes the build number. Denotes a scheduled maintenance release of the firmware. Denotes a minor release of the firmware. Denotes a major release of the firmware. • Major release numbers start at 6. • Minor release numbers start at 0. • Maintenance release numbers start at 0. • Build numbers start at 1. Examples: • N3000_N2000v6.0.1.3.stk — N3000/N2000 series switch firmware version 6.0.1.3. This is the third build for the first maintenance release for the 6.0 major release. • N4000v6.1.0.1.stk — N4000 series switch firmware version 6.1.0.1. This is the first build for the first minor release after the 6.0 major release, i.e., release 6.1. Configuration Files Configuration files contain the CLI commands that change the switch from its default configuration. The switch can maintain three separate configuration files: startup-config, running-config, and backup-config. The switch loads the startup-config file when the switch boots. Any configuration changes that take place after the boot process completes are written to the 362 Managing Images and Files running-config file. The backup-config file does not exist until you explicitly create one by copying an existing configuration file to the backup-config file or downloading a backup-config file to the switch. You can also create configuration scripts, which are text files that contains CLI commands. NOTE: You must use the CLI to manage configuration scripts. The configuration scripting feature is not available from the web interface. When you apply (run) a configuration script on the switch, the commands in the script are executed in the order in which they are written as if you were typing them into the CLI. The commands that are executed in the configuration script are added to the running-config file. You might upload a configuration file from the switch to a remote server for the following reasons: • To create a backup copy • To use the configuration file on another switch • To manually edit the file You might download a configuration file from a remote server to the switch for the following reasons: • To restore a previous configuration • To load the configuration copied from another switch • To load the same configuration file on multiple switches Use a text editor to open a configuration file and view or change its contents. SSH/SSL Files If you use OpenManage Switch Administrator to manage the switch over an HTTPS connection, you must copy the appropriate certificate files to the switch. If you use the CLI to manage the switch over an SSH connection, you must copy the appropriate key files to the switch. What Methods Are Supported for File Management? You can use any of the following protocols to download files from a remote system to the switch or to upload files from the switch to a remote system: Managing Images and Files 363 • TFTP • SFTP • SCP • FTP • HTTP (Web only) • HTTPS (Web only) You can also copy files between the file system on the internal flash and a USB flash drive that is connected to the external USB port. What Factors Should Be Considered When Managing Files? Uploading and Downloading Files To use TFTP, SFTP, SCP, or FTP for file management, you must provide the IP address of the remote system that is running the appropriate server (TFTP, SFTP, SCP or FTP). Make sure there is a route from the switch to the remote system. You can use the ping command from the CLI to verify that a route exists between the switch and the remote system. If you are downloading a file from the remote system to the switch, be sure to provide the correct path to the file and the correct file name. Managing Images When you download a new image to the switch, it overwrites the backup image, if it exists. To use the new image, you must activate it and reload the switch. The image that was previously the active image becomes the backup image after the switch reloads. If you upgrade to a newer image and find that it is not compatible with your network, you can revert to the original image. If you activate a new image and reload the switch, and the switch is unable to complete the boot process due to a corrupt image or other problem, you can use the boot menu to activate the backup image. You must be connected to the switch through the console port to access the boot menu. The image files may contain firmware for the PHY processors on the switch. The PHY firmware may be updated to the firmware version supported by the switch firmware during the boot process or, in the case of switches that support the hot swap of cards, when the card is inserted into the switch. 364 Managing Images and Files Editing and Downloading Configuration Files Each configuration file contains a list of executable CLI commands. The commands must be complete and in a logical order, as if you were entering them by using the switch CLI. When you download a startup-config or backup-config file to the switch, the new file replaces the previous version. To change the running-config file, you execute CLI commands either by typing them into the CLI or by applying a configuration script with the script apply command. The startup-config and backup-config files can also be applied to the running-config by using the script apply command. Creating and Applying Configuration Scripts When you use configuration scripting, keep the following considerations and rules in mind: • The application of scripts is partial if the script fails. For example, if the script executes four of ten commands and the script fails, the script stops at four, and the final six commands are not executed. • Scripts cannot be modified or deleted while being applied. • Validation of scripts checks for syntax errors only. It does not validate that the script will run. • The file extension must be .scr. • A maximum of seven scripts are allowed on the switch. • The combined size of all script files on the switch cannot exceed 2 MB. • The maximum number of configuration file command lines is 2000. You can type single-line annotations in the configuration file to improve script readability. The exclamation point (!) character flags the beginning of a comment. The comment flag character can begin anywhere within a single line, and all input following this character to the end of the line is ignored. Any line in the file that begins with the “!” character is recognized as a comment line and ignored by the parser. The following example shows annotations within a file (commands are bold): ! Script file for displaying management access show telnet !Displays the information about remote connections Managing Images and Files 365 ! Display information about direct connections show serial ! End of the script file Managing Files on a Stack Image files downloaded to the master unit of a stack are automatically downloaded to all stack members. If you activate the backup image on the master, it is activated on all units as well so that when you reload the stack, all units use the same image. The running-config, startup-config, and backup-config files, as well as all keys and certificates are synchronized across the stack when the running-config file is saved to the startup-config file. Configuration scripts are not distributed across the stack and only exist on the unit that is the master unit at the time of the file download. Uploading Configuration Files by Using SNMP When you use SNMP to upload a configuration file to a TFTP server, the agentTransferUploadFileName object must be set to the local filename, which is either startup-config or backup-config. How Is the Running Configuration Saved? Changes you make to the switch configuration while the switch is operating are written to the running-config. These changes are not automatically written to the startup-config. When you reload the switch, the startup-config file is loaded. If you reload the switch (or if the switch resets unexpectedly), any settings in the running-config that were not explicitly saved to the startup-config are lost. You must save the running-config to the startupconfig to ensure that the settings you configure on the switch are saved across a switch reset. To save the running-config to the startup-config by using the web-based interface, click (the save icon), which is available at the top of each page. To save the running-config to the startup-config from the CLI, use the write command. 366 Managing Images and Files Managing Images and Files (Web) This section provides information about the OpenManage Switch Administrator pages to use to manage images and files on a Dell Networking N2000, N3000, and N4000 series switches. For details about the fields on a page, click at the top of the page. File System Use the File System page to view a list of the files on the device and to modify the image file descriptions. To display the File System page, click System → File Management → File System in the navigation panel. Figure 14-1. File System Managing Images and Files 367 Active Images Use the Active Images page to set the firmware image to use when the switch boots. If you change the boot image, it does not become the active image until you reset the switch. On the N4000 series switches, the images are named active and backup. NOTE: To display the Active Images page, click System → File Management → Active Images in the navigation panel. Figure 14-2. Active Images 368 Managing Images and Files USB Flash Drive Use the USB Flash Drive page to view information about a USB flash drive connected to the USB port on the front panel of the switch. The page also displays information about the files stored on the USB flash drive. A USB flash drive must be un-mounted by the operator before removing it from the switch. If a new USB flash drive is installed without un-mounting the previous drive, the new flash drive may not be recognized. If a USB flash drive is removed without un-mounting it, un-mount the flash drive (i.e., use the command unmount usb) and remove and reinstall the USB flash drive in the switch. To display the USB Flash Drive page, click System → File Management → USB Flash Drive in the navigation panel. Figure 14-3. USB Flash Drive Managing Images and Files 369 File Download Use the File Download page to download image (binary) files, SSH and SSL certificates, IAS User files, and configuration (ASCII), files from a remote server to the switch. To display the File Download page, click System → File Management → File Download in the navigation panel. Figure 14-4. File Download Downloading Files To download a file to the switch: 1 Open the File Download page. 2 Select the type of file to download to the switch. 3 Select the transfer mode. 370 Managing Images and Files If you select a transfer mode that requires authentication, additional fields appear in the Download section. If you select HTTP as the download method, some of the fields are hidden. NOTE: If you are using HTTPS to manage the switch, the download method will be HTTPS. 4 To download using HTTP, click Browse and select the file to download, then click Apply. 5 To download using any method other than HTTP, enter the IP address of the server that contains the file to download, the name of the file and the path on the server where it is located. For SFTP and SCP, provide the user name and password. 6 Click Apply to begin the download. NOTE: After you start a file download, the page refreshes and a transfer status field appears to indicate the number of bytes transferred. The web interface is blocked until the file download is complete. Figure 14-5. File Download in Progress 7 The file is downloaded to the switch. Managing Images and Files 371 File Upload Use the File Upload to Server page to upload configuration (ASCII), image (binary), IAS user, operational log, and startup log files from the switch to a remote server. To display the File Upload to Server page, click System → File Management → File Upload in the navigation panel. Figure 14-6. File Upload Uploading Files To upload a file from the switch to a remote system: 1 Open the File Upload page. 2 Select the type of file to download to the remote server. 3 Select the transfer mode. If you select a transfer mode that requires authentication, additional fields appear in the Upload section. If you select HTTP as the upload method, some of the fields are hidden. 372 Managing Images and Files NOTE: If you are using HTTPS to manage the switch, the download method will be HTTPS. 4 To upload by using HTTP, click Apply. A dialog box opens to allow you to open or save the file. Figure 14-7. File Upload 5 To upload by using any method other than HTTP, enter the IP address of the server and specify a name for the file. For SFTP and SCP, provide the user name and password. 6 Click Apply to begin the upload. NOTE: For some file uploads and methods, the page refreshes and a transfer status field appears to indicate the number of bytes transferred. The web interface is blocked until the file upload is complete. 7 The file is uploaded to the specified location on the remote server. Managing Images and Files 373 Copy Files Use the Copy Files page to: • Copy the active firmware image to the switch. one or all members of a stack. • Copy the running, startup, or backup configuration file to the startup or backup configuration file. • Restore the running configuration to the factory default settings. To display the Copy Files page, click System → File Management → Copy Files in the navigation panel. Figure 14-8. Copy Files 374 Managing Images and Files Managing Images and Files (CLI) This section provides information about the commands you use to upload, download, and copy files to and from the Dell Networking N2000, N3000, and N4000 series switches. For more information about these commands, see the Dell Networking N2000, N3000, and N4000 Series Switches CLI Reference Guide at support.dell.com/manuals. It also describes the commands that control the Auto Configuration feature. NOTE: Upload, download, and copy functions use the copy command. The basic syntax for the command is copy source destination. This section shows several different ways to use the copy command. Downloading and Activating a New Image (TFTP) Beginning in Privileged EXEC mode, use the following commands to download a new firmware image to the switch and to make it the active image. This example shows how to use TFTP to download the image. Command Purpose copy tftp://{ip-address| hostname}/path/filename image Use TFTP to download the firmware image at the specified source to the non-active image. If the image file is in the TFTP file system root (download path), you do not need to specify the path in the command. On N4000 series switches, use the following command: copy tftp://{ip-address| hostname}/path/file-name {active | backup} show version View information about the currently active image. filedescr {image1 | image2} description Add a description to the image files. On N4000 series switches, use the following command: filedescr {active | backup} description Managing Images and Files 375 Command Purpose boot system {image1 | image2} Set the image to use as the boot (active) image after the switch resets. Images on the N4032/N4064 are named active and backup. For N4000 series switches, use the following command: boot system {active | backup} reload Reboot the switch to make the new image the active image. You are prompted to verify that you want to continue. 376 Managing Images and Files Managing Files in Internal Flash Beginning in Privileged EXEC mode, use the following commands to copy, rename, delete and list the files in the internal flash. Command Purpose dir List the files in the flash file system. copy flash://filename usb://filename Copy a file from the internal flash to a USB flash drive. Use the dir command to see a list of the files that can be copied from the internal flash. Make sure a flash drive has been inserted in the USB port on the front panel before executing the command. rename current_name new_name Rename a file in flash. delete filename Remove the specified file. erase {startup-config | Erase the startup configuration, the backup configuration backup-image | backup- or the backup image. config} copy startup-config backup-config Save the startup configuration to the backup configuration file. copy running-config startup-config Copy the current configuration to the startup configuration. This saves the current configuration to NVRAM. show startup-config View the contents of the startup-config file show running-config View the contents of the running-config file Command Purpose dir List the files in the flash file system. rename current_name new_name Rename a file in flash. delete filename Remove the specified file. erase {startup-config | Erase the startup configuration, the backup configuration backup-image | backup- or the backup image. config} Managing Images and Files 377 Command Purpose copy startup-config backup-config Save the startup configuration to the backup configuration file. copy running-config startup-config Copy the current configuration to the startup configuration. This saves the current configuration to NVRAM. show startup-config View the contents of the startup-config file show running-config View the contents of the running-config file 378 Managing Images and Files Managing Files on a USB Flash Device Beginning in Privileged EXEC mode, use the following commands to manage files that are on a USB device that is plugged into the USB flash port on the front panel of the switch. Command Purpose show usb device Display USB flash device details dir usb Display USB device contents and memory statistics copy usb://filename Copy the specified file from the USB flash device to the {backup-config | image specified file in internal flash. | running-config | script filename| startup-config | filename unmount usb Make the USB flash device inactive. Uploading a Configuration File (SCP) Beginning in Privileged EXEC mode, use the following commands to upload a configuration file from the switch to a remote system by using SCP. Command Purpose copy file scp://user@{ip- Adds a description to an image file. address|hostname}/path The file can be one of the following files: /file-name • backup-config • image • operational-log • running-config • script file-name • startup-config • startup-log Password entry After you enter the copy command, the CLI prompts you for the password associated with the username. Managing Images and Files 379 Managing Configuration Scripts (SFTP) Beginning in Privileged EXEC mode, use the following commands to download a configuration script from a remote system to the switch, validate the script, and activate it. NOTE: The startup-config and backup-config files are essentially configuration scripts and can be validated and applied by using the commands in this section. Command Purpose Downloads the specified script from the remote server to copy sftp://user@{ipaddress|hostname}/path the switch. /file-name script dest- name Password entry After you enter the copy command, the CLI prompts you for the password associated with the username. script validate script- Checks the specified script for syntax errors. name The script is automatically validated when you download it to the switch. You can validate again with this command. script list View the list of available scripts. name script activate script- Executes the commands within the script in order. The configuration changes in the script are applied to the running configuration. script show script-name View the contents of the specified script. 380 Managing Images and Files File and Image Management Configuration Examples This section contains the following examples: • Upgrading the Firmware • Managing Configuration Scripts Upgrading the Firmware This example for a N4032 shows how to download a firmware image to the switch and activate it. The TFTP server in this example is PumpKIN, an open source TFTP server running on a Windows system. • TFTP server IP address: 10.27.65.103 • File path: \image • File name: dell_0308.stk Use the following steps to prepare the download, and then download and upgrade the switch image. 1 Check the connectivity between the switch and the TFTP server. console#ping 10.27.65.103 Pinging 10.27.65.103 with 0 bytes of data: Reply Reply Reply Reply From From From From 10.27.65.103: 10.27.65.103: 10.27.65.103: 10.27.65.103: icmp_seq icmp_seq icmp_seq icmp_seq = = = = 0. 1. 2. 3. time time time time <10 <10 <10 <10 msec. msec. msec. msec. ----10.27.65.103 PING statistics---4 packets transmitted, 4 packets received, 0% packet loss round-trip (msec) min/avg/max = <10/<10/<10 2 Copy the image file to the appropriate directory on the TFTP server. In this example, the TFTP root directory is C:\My Documents\Other\Downloads\TFTP., so the file path is images. Managing Images and Files 381 Figure 14-9. Image Path 3 View information about the current image. console#show version Image Descriptions image1 :default image image2 : Images currently available on Flash ------- ------------ ------------ --------------- -------------unit image1 image2 current-active next-active ------- ------------ ------------ --------------- -------------1 4.1.0.7 5.0.0.8 image1 image1 4 Download the image to the switch. After you execute the copy command, you must verify that you want to start the download. The downloaded image replaces the currently inactive image, which may be image1 or image2.Use either the active or backup keyword to have the image to replace the specified image type (which takes effect only after a reboot). In the following example, the active image is replaced. console#copy tftp://10.27.65.103/images/dell_0308.stk imageactive Mode........................................... TFTP 382 Managing Images and Files Set TFTP Server IP............................. TFTP Path...................................... TFTP Filename.................................. Data Type...................................... Destination Filename........................... 10.27.65.103 images/ dell_0308.stk Code image Management access will be blocked for the duration of the transfer Are you sure you want to start? (y/n)y 5 Activate the new image (image2) so that it becomes the active image after the switch resets. Use either the active or backup keyword, depending on which file type you selected for replacement in step 4. console#boot system activeimage2 Activating image activeimage2.. 6 View information about the current image. console#show bootvar Image Descriptions image1 : image2 : Images currently available on Flash ------- ------------ ------------ --------------- -------------unit image1 image2 current-active next-active ------- ------------ ------------ --------------- -------------1 4.1.0.7 5.0.0.8 image1 image2 7 Copy the running configuration to the startup configuration to save the current configuration to NVRAM. console#copy running-config startup-config This operation may take a few minutes. Management interfaces will not be available during this time. Are you sure you want to save? (y/n)y Managing Images and Files 383 Configuration Saved! 8 Reset the switch to boot the system with the new image. console#reload Are you sure you want to continue? (y/n)y Reloading all switches... Managing Configuration Scripts This example shows how to create a configuration script that adds three hostname-to-IP address mappings to the host table. To configure the switch: 1 Open a text editor on an administrative computer and type the commands as if you were entering them by using the CLI. Figure 14-10. Create Config Script 2 Save the file with an *.scr extension and copy it to the appropriate directory on your TFTP server. 3 Download the file from the TFTP server to the switch. 384 Managing Images and Files console#copy tftp://10.27.65.103/labhost.scr script labhost.scr Mode........................................... Set TFTP Server IP............................. TFTP Path...................................... TFTP Filename.................................. Data Type...................................... Destination Filename........................... TFTP 10.27.65.103 ./ labhost.scr Config Script labhost.scr Management access will be blocked for the duration of the transfer 4 After you confirm the download information and the script successfully downloads, it is automatically validated for correct syntax. Are you sure you want to start? (y/n) y 135 bytes transferred Validating configuration script... configure exit configure ip host labpc1 192.168.3.56 ip host labpc2 192.168.3.58 ip host labpc3 192.168.3.59 Configuration script validated. File transfer operation completed successfully. 5 Run the script to execute the commands. console#script apply labhost.scr Are you sure you want to apply the configuration script? (y/n)y configure exit configure ip host labpc1 192.168.3.56 Managing Images and Files 385 ip host labpc2 192.168.3.58 ip host labpc3 192.168.3.59 Configuration script 'labhost.scr' applied. 6 Verify that the script was successfully applied. console#show hosts Host name: test Name/address lookup is enabled Name servers (Preference order): 192.168.3.20 Configured host name-to-address mapping: Host Addresses ------------------------ -----------------------labpc1 192.168.3.56 labpc2 192.168.3.58 labpc3 192.168.3.59 Managing Files by Using the USB Flash Drive In this example, the administrator copies the backup image to a USB flash drive before overwriting the backup image on the switch with a new image. The administrator also makes a backup copy of the running-config by uploading it to a USB flash drive. After the backups are performed, the administrator downloads a new image from the USB flash drive to the switch to prepare for the upgrade. This example assumes the new image is named new_img.stk and has already been copied from an administrative host onto the USB flash drive. To configure the switch: 1 Insert the USB flash drive into the USB port on the front panel of the switch. The USB flash drive is automatically mounted. 2 Copy the backup image from the switch to the USB flash drive. console#copy image usb://img_backup.stk Mode................................... unknown 386 Managing Images and Files Data Type.............................. Code Management access will be blocked for the duration of the transfer Are you sure you want to start? (y/n) y 3 Copy the running-config to the USB flash drive. console#copy running-config usb://rc_backup.scr Mode............................. unknown Data Type........................ Config Script Source Filename.................. temp-config.scr Management access will be blocked for the duration of the transfer Are you sure you want to start? (y/n) y 4 Download the new image from the USB flash drive to the switch. The image overwrites the image that is not currently active. console#copy usb://new_image.stk image Mode................................... unknown Data Type.............................. Code Management access will be blocked for the duration of the transfer Are you sure you want to start? (y/n) y 5 To activate the new image after it has been successfully downloaded to the switch, follow the procedures described in Upgrading the Firmware, starting with step 5. Managing Images and Files 387 388 Managing Images and Files 15 Automatically Updating the Image and Configuration The topics covered in this chapter include: • Auto Configuration Overview • What Are the Dependencies for DHCP Auto Configuration? • Default Auto Configuration Values • Managing Auto Configuration (Web) • Managing Auto Configuration (CLI) • Auto Configuration Example Auto Configuration Overview The Auto Configuration feature can automatically update the firmware image and obtain configuration information when the switch boots. Auto Configuration begins the automatic download and installation process when the switch or stack master is initialized and no configuration file (startupconfig) is found, or when the switch boots and loads a saved configuration that has Auto Configuration enabled. Auto Configuration is enabled by default. Allow downgrade is also enabled by default. The Auto Configuration feature includes two components: • USB Auto Configuration • DHCP Auto Install If no configuration file is found and the Auto Configuration feature is enabled (which it is by default), the Auto Configuration process begins. If a USB device is connected to the Dell Networking switch USB port and contains the appropriate file, the switch uses the USB Auto Configuration feature to update the configuration or image. If the USB Auto Configuration Auto Image and Configuration Update 389 fails - either because it is disabled, no USB storage device is present, or no configuration or images files are present on the USB storage device, the switch uses the DHCP Auto Install process. NOTE: Neither USB Configuration nor Auto Install is invoked if a valid configuration file is on the switch. What Is USB Auto Configuration? You can use the USB Auto Configuration feature to configure or upgrade one or more switches that have not been previously configured, such as when you deploy new switches. Before you deploy the switch, you perform the following steps: 1 Create a text file that contains IP addresses (and/or MAC addresses) and file names that are parsed and used by this feature. The optional MAC address used to identify the switch is the MAC address of the base MAC address of the switch, although the feature will accept any of the switch MAC addresses (see "Switch MAC Addresses" on page 125 for further information). The IP address is a required field in the configuration file. Refer to the example below for an explanation of the file format. 2 Copy the file onto a USB device, along with any desired switch firmware and configuration files. 3 Insert the USB device into the front-panel USB port on the Dell Networking switch. When the Auto Configuration process starts and no startup-config file is present on the switch, the feature automatically searches a plugged-in USB device for information. What Files Does USB Auto Configuration Use? The USB Auto Configuration feature uses the following file types: • *.setup file for initial switch configuration • *.text file for configuration information • *.stk file for software image installation The Auto Configuration file searches the USB device for a file with a *.setup extension. If only one .setup file is present, the switch uses the file. When multiple *.setup files are present, the switch uses only the dellswitch.setup 390 Auto Image and Configuration Update file. If no dellswitch.setup file is available, the switch checks for a file with a *.text configuration file and a *.stk image file. If multiple .text files exist, the switch uses the dellswitch.text file. If multiple *.stk files are present, the switch uses the image with the highest (most recent) version. Finally, if no *.setup, *.text, or *.stk files are found, the switch proceeds to the DHCP Auto Configuration process. How Does USB Auto Configuration Use the Files on the USB Device? The *.setup file can include the following information: • MAC address of the switch (optional) • Configuration file name (optional) • Image file name (optional) • IP address (mandatory) MAC Address Lookup The MAC address should be on the same line as the configuration file and/or image file name to allow a specific switch (identified by its MAC address) to be associated with a specific config file or image. If an IP address also exists on the line, this indicates a previous binding and requires this IP address to be configured for the management IP address. IP Address Lookup If the switch MAC address is not found within the .setup text file, the first line that contains an IP address and no MAC address and is not marked in-use will be used by the switch to assign the management IP address/netmask. The IP address line should include the configuration filename and/or image filename for the switch. This method allows a group of IP addresses to be handed out without regard to the specific switch identified by the MAC address. A switch will mark a line as invalid if it is read and failed to properly parse if, for example, it contains an invalid configuration, a duplicate IP address or an image file name that is not available. Once a switch selects an IP address from the file, it adds its MAC address to the line, marks the line as inuse, and updates the file on the USB device. If the *.setup file contains IP addresses but no file names, the management IP address will be assigned, and then the feature will search the USB device for files with the .text and .stk extensions, which indicates that all switches will Auto Image and Configuration Update 391 be using the same configuration file and/or image on the USB device. This method allows different IP addresses to be assigned, but the same configuration file or image is downloaded to multiple switches. After the current switch has been configured and/or upgraded and the completion message is displayed on the switch, the current line in the *.setup text file will be marked as used. This allows you to use the *.setup file for additional switches without manually changing the file. You can then remove the USB device and insert it into the next switch to begin the process again. Also, the switch MAC address of the switch that has been automatically configured is added to the beginning of the line (if no MAC address was specified in the file) for lines using the IP address lookup method so that the MAC and IP address combinations are recorded within the *.setup file for future use bindings. At the start of the next USB auto download, if all lines in the *.setup file are marked as already “in-use” or “invalid,” and there is no MAC address match for a switch, the process will halt, and a message similar to the following is displayed on the console: <###> APR 22 08:32:43 Error: Auto Configuration has terminated due to there being no more lines available for use within the USB file “XXXXX.setup”. Configuration File The *.text configuration file identified in the *.setup file contains the running-config to be loaded on to the switch. The configuration file specified in the *.setup file should exist on the USB device. For information about the format and contents of the *.text file, see Editing and Downloading Configuration Files. Image File If the Auto Configuration process includes a switch image upgrade, the name of the image file should be included in the *.setup file. The specified image file should exist on the USB device. What Is the Setup File Format? The setup file must have a *.setup extension or this part of the feature will never begin. If there are multiple .setup files located on the USB device, the dellswitch.setup file will take precedence. 392 Auto Image and Configuration Update The general format of the configuration file lines is as follows. The IP address and subnet mask are required. The MAC address, configuration file, and image file name entries are optional. MAC_address IP_Address Subnet_Mask Config_File Image_File The following example shows a *.setup example for two switches: 2180.c200.0010 192.168.0.10 255.255.255.0 switch-A.text N2000vR.5.4.1.stk 3380.c200.0011 192.168.0.11 255.255.255.0 switch-B.text N2000vR.5.4.1.stk After a line has been read and implemented by the Auto Configuration feature, it automatically adds “in-use” to the end of the line to ensure that the information is not used for the next switch. To replicate the entire USB auto configuration process, the “in-use” statements from the .setup file need to be removed. Then, if the process is restarted, the MAC address/IP address combinations will be ensured for any switch that has previously attempted upgrade and all other switch upgrades can take place as if for the first time. What Is the DHCP Auto Configuration Process? If the USB Auto Configuration fails or is not used, the switch can use a DHCP server to obtain configuration information from a TFTP server. DHCP Auto Configuration is accomplished in three phases: 1 Assignment or configuration of an IP address for the switch 2 Assignment of a TFTP server 3 Obtaining a configuration file for the switch from the TFTP server Auto Configuration is successful when an image or configuration file is downloaded to the switch or stack master from a TFTP server. NOTE: The downloaded configuration file is not automatically saved to startupconfig. You must explicitly issue a save request (copy running-config startupconfig) in order to save the configuration. Auto Image and Configuration Update 393 Obtaining IP Address Information DHCP is enabled by default on the Out-of-Band (OOB) interface on N3000 and N4000 switches. DHCP is enabled by default on VLAN 1 on the N2000 switches. If an IP address has not been assigned, the switch issues requests for an IP address assignment. A network DHCP server returns the following information: • IP address and subnet mask to be assigned to the interface • IP address of a default gateway, if needed for IP communication After an IP address is assigned to the switch, if a hostname is not already assigned, Auto Configuration issues a DNS request for the corresponding hostname. This hostname is also displayed as the CLI prompt (as in response to the hostname command). Obtaining Other Dynamic Information The following information is also processed and may be returned by a BOOTP or DHCP server: • Name of configuration file (the file field in the DHCP header or option 67) to be downloaded from the TFTP server. • Identification of the TFTP server providing the file. The TFTP server can be identified by name or by IP address as follows: – hostname: DHCP option 66 or the sname field in the DHCP header) – IP address: DHCP option 150 or the siaddr field in the DHCP header When a DHCP OFFER identifies the TFTP server more than once, the DHCP client selects one of the options in the following order: sname, option 66, option 150, siaddr. If the TFTP server is identified by hostname, a DNS server is required to translate the name to an IP address. The DHCP client on the switch also processes the name of the text file (option 125, the V-I vendor-specific Information option) which contains the path to the image file. 394 Auto Image and Configuration Update Obtaining the Image Auto Configuration attempts to download an image file from a TFTP server only if no configuration file was found in the internal flash or a USB drive, or even with a saved configuration file that has Auto Configuration enabled. The network DHCP server may return a DHCP OFFER message with option 125. When configuring the network DHCP server for image downloads, you must include Option 125 and specify the Dell Enterprise Number, 674. Within the Dell section of option 125, sub option 5 must specify the path and name of a file on the TFTP server. This file is not the image file itself, but rather a text file that contains the path and name of the image file. Upon receipt of option 125, the switch downloads the text file from the TFTP server, reads the name of the image file, and downloads the image file from the TFTP server. After the switch successfully downloads and installs the new image, it automatically reboots. The download or installation might fail for one of the following reasons: • The path or filename of the image on the TFTP server does not match the information specified in DHCP option 125. • The downloaded image is the same as the current image. • The validation checks, such as valid CRC Checksum, fails. If the download or installation was unsuccessful, a message is logged. NOTE: In stack of switches, the downloaded image is pushed to all members attached to the stack at the time of download. For members who join the stack after the download, the Stack Firmware Synchronization feature will push the latest image to all members. Obtaining the Configuration File If the DHCP OFFER identifies a configuration file, either as option 67 or in the file field of the DHCP header, the switch attempts to download the configuration file. NOTE: The configuration file is required to have a file type of *.cfg. Auto Image and Configuration Update 395 The TFTP client makes three unicast requests. If the unicast attempts fail, or if the DHCP OFFER did not specify a TFTP server address, the TFTP client makes three broadcast requests. If the DHCP server does not specify a configuration file or download of the configuration file fails, the Auto Configuration process attempts to download a configuration file with the name dell-net.cfg. The switch unicasts or broadcasts TFTP requests for a network configuration file in the same manner as it attempts to download a host-specific configuration file. The default network configuration file consists of a set of IP address-tohostname mappings, using the command ip host hostname address. The switch finds its own IP address, as learned from the DHCP server, in the configuration file and extracts its hostname from the matching command. If the default network configuration file does not contain the switch's IP address, the switch attempts a reverse DNS lookup to resolve its hostname. A sample dell-net.cfg file follows: config ... ip host switch1 192.168.1.10 ip host switch2 192.168.1.11 ... exit Once a hostname has been determined, the switch issues a TFTP request for a file named hostname.cfg , where hostname is the first thirty-two characters of the switch's hostname. If the switch is unable to map its IP address to a hostname, Auto Configuration sends TFTP requests for the default configuration file host.cfg. 396 Auto Image and Configuration Update Table 15-1 summarizes the config files that may be downloaded and the order in which they are sought. Table 15-1. Configuration File Possibilities Order Sought File Name Description Final File Sought 1 bootfile.cfg Host-specific config file, ending in a *.cfg file extension Yes 2 dell-net.cfg Default network config file No 3 hostname.cfg Host-specific config file, associated with hostname. Yes 4 host.cfg Default config file Yes Table 15-2 displays the determining factors for issuing unicast or broadcast TFTP requests. Table 15-2. TFTP Request Types TFTP Server Address Available Host-specific Switch Config Filename Available TFTP Request Method Yes Yes Issue a unicast request for the host-specific router config file to the TFTP server Yes No Issue a unicast request for a default network or router config file to the TFTP server No Yes Issue a broadcast request for the hostspecific router config file to any available TFTP server No No Issue a broadcast request for the default network or router config file to any available TFTP server Auto Image and Configuration Update 397 Monitoring and Completing the DHCP Auto Configuration Process When the switch boots and triggers an Auto Configuration, a message displays on the console screen to indicate that the process is starting. After the process completes, the Auto Configuration process writes a log message. When Auto Configuration has successfully completed, you can execute a show running-config command to validate the contents of configuration. Saving a Configuration The Auto Configuration feature includes an AutoSave capability that allows the downloaded configuration to be automatically saved; however, AutoSave is disabled by default. If AutoSave has not been enabled, you must explicitly save the downloaded configuration in nonvolatile memory on the stack master. This makes the configuration available for the next reboot. In the CLI, this is performed by issuing a write command or copy running-config startup-config command and should be done after validating the contents of saved configuration. Stopping and Restarting the Auto Configuration Process You can terminate the Auto Configuration process at any time before the image or configuration file is downloaded. This is useful when the switch is disconnected from the network. Termination of the Auto Configuration process ends further periodic requests for a host-specific file. The Auto Configuration process automatically starts after a reboot if the configuration file is not found on the switch. The configuration file will not be found if it has never been saved on the switch, or if you issue a command to erase the configuration file (clear config or erase startup-config). Managing Downloaded Config Files The configuration files downloaded by Auto Configuration are stored in the nonvolatile memory as .scr files. The files may be managed (viewed or deleted) along with files downloaded by the configuration scripting utility. A file is not automatically deleted after it is downloaded. The file does not take effect upon a reboot unless you explicitly save the configuration (the saved configuration takes effect upon reboot). If you do not save the configuration downloaded by the Auto Configuration feature, the Auto Configuration process occurs again on a subsequent reboot. This may result in one of the previously downloaded files being overwritten. 398 Auto Image and Configuration Update What Are the Dependencies for DHCP Auto Configuration? The Auto Configuration process from TFTP servers depends upon the following network services: • A DHCP server must be configured on the network with appropriate services. • An image file and a text file containing the image file name for the switch must be available from a TFTP server if DHCP image download is desired. • A configuration file (either from bootfile (or) option 67 option) for the switch must be available from a TFTP server. • The switch must be connected to the network and have a Layer 3 interface that is in an UP state. • A DNS server must contain an IP address to hostname mapping for the TFTP server if the DHCP server response identifies the TFTP server by name. • A DNS server must contain an IP address to hostname mapping for the switch if a .cfg file is to be downloaded. • If a default gateway is needed to forward TFTP requests, an IP helper address for TFTP needs to be configured on the default gateway. Auto Image and Configuration Update 399 Default Auto Configuration Values Table 15-3 describes the Auto Configuration defaults. Table 15-3. Auto Configuration Defaults Feature Default Description Auto Install Mode Enabled When the switch boots and no saved configuration is found, the Auto Configuration automatically begins. Retry Count 3 When the DHCP or BootP server returns information about the TFTP server and bootfile, the switch makes three unicast TFTP requests for the specified bootfile. If the unicast attempts fail or if a TFTP server address was not provided, the switch makes three broadcast requests to any available TFTP server for the specified bootfile. AutoSave Disabled If the switch is successfully auto-configured, the running configuration is not saved to the startup configuration. AutoReboot Enabled After an image is successfully downloaded during the Auto Configuration process, the switch automatically reboots and makes the downloaded image the active image. 400 Auto Image and Configuration Update Managing Auto Configuration (Web) This section provides information about the OpenManage Switch Administrator pages to use to manage images and files on a Dell Networking N2000, N3000, and N4000 series switches. For details about the fields on a page, click at the top of the page. Auto-Install Configuration Use the Auto-Install Configuration page to allow the switch to obtain network information (such as the IP address and subnet mask) and automatically download a host-specific or network configuration file during the boot process if no startup-config file is found. To display the Auto Configuration page, click System → General → AutoInstall Configuration in the navigation panel. Figure 15-1. Auto-Install Configuration Auto Image and Configuration Update 401 Managing Auto Configuration (CLI) This section provides information about the commands you manage the Auto-Install Configuration feature on the switch. For more information about these commands, see the Dell Networking N2000, N3000, and N4000 Series Switches CLI Reference Guide at support.dell.com/manuals. Managing Auto Configuration Beginning in Privileged EXEC mode, use the following commands to manually activate the Auto Configuration process and download a configuration script from a remote system to the switch, validate the script, and activate it. NOTE: The Auto Configuration feature begins automatically when the switch is booted and no startup-config file is found or if the system boots and finds the boot host dhcp command in the startup-config file. Command Purpose configure Enter Global Configuration mode. boot host dhcp Enable Auto Configuration for the next reboot cycle. The command does not change the current behavior of Auto Configuration, but it does save the command to NVRAM. boot host auto-save Allow the switch to automatically save the configuration file downloaded to the switch by the Auto Configuration feature. boot host retry-count Specify the number of attempts to download the file (by sending unicast TFTP requests, and if unsuccessful, broadcast TFTP requests) specified in the response from the DHCP server. retries The range for retries is 1–3. boot host auto-reboot Allow the switch to automatically reboot when the image is successfully downloaded through the Auto Configuration feature. exit Exit to Privileged Exec mode. show boot Displays the current status of the Auto Configuration process. 402 Auto Image and Configuration Update Auto Configuration Example A network administrator is deploying three Dell Networking switches and wants to quickly and automatically install the latest image and a common configuration file that configures basic settings such as VLAN creation and membership, RADIUS server settings, and 802.1X information. The configuration file also contains the command boot host autosave so that the downloaded configuration is automatically saved to the startup config. This section describes two ways to enable automatic configuration file download: • Enabling USB Auto Configuration and Auto Image Download • Enabling DHCP Auto Configuration and Auto Image Download Enabling USB Auto Configuration and Auto Image Download This example describes how to deploy three switches and automatically install a custom configuration file on the switch and upgrade each switch with the latest software image by using the USB Auto Configuration feature. The switches have the following MAC addresses: • Switch A: 001E.C9AA.AC17 • Switch B: 001E.C9AA.AC20 • Switch C: 001E.C9AA.AC33 To configure each switch with a static IP address, you can include the IP address in the .setup file or in the configuration file (.text) for the switch. Otherwise, the switch can obtain an IP address from a DHCP server on the network. To use USB auto configuration: 1 Create a default config file for each switch. The configuration files are named switchA.txt, switchB.txt, and switchC.txt. For information about creating configuration files, see Managing Images and Files. 2 Copy the configuration files to a USB device. 3 Copy the image file to the device. In this example, the image file that each switch will download is named N2000vR.5.4.1.stk. Auto Image and Configuration Update 403 4 Create a setup file named dellswitch.setup. The setup file contains the following lines: 001E.C9AA.AC17 switchA.txt N2000vR.5.4.1.stk 001E.C9AA.AC20 switchB.txt N2000vR.5.4.1.stk 001E.C9AA.AC33 switchC.txt N2000vR.5.4.1.stk NOTE: This .setup file does not provide the switch with a static IP address. However, the switchA.txt, switchB.txt, and switchC.txt files can contain the commands required to configure a static IP address on each switch. Otherwise, the switch will use DHCP to attempt to acquire an IP address. 5 Copy the dellswitch.setup file to the USB device. 6 Connect the USB device to Switch A. 7 Connect Switch A to the network. Make sure that a port (OOB port for out-of-band management or any switch port for in-band management) is connected to the network and that a DHCP server is accessible on the network. 8 Insert the USB device into the USB port on the front panel of Switch A. 9 Power on Switch A. If no startup-config file is found, the Easy Startup wizard will begin. Press N to skip the Easy Startup wizard and the USB Auto Configuration process will begin. If necessary, delete the startupconfig file and reboot the switch. The configuration in switchA.txt file is downloaded to the switch, and the management interface acquires network information. After the process completes, a message displays to indicate the status. The dellswitch.setup file is updated to add the term in-use to the end of the line. The N2000vR.5.4.1.stk image is also downloaded to the switch. 10 Remove the USB device from Switch A and insert it into Switch B. 11 Repeat the process to connect a port to the network. Power on the switch to begin the USB Auto Configuration process on Switch B. 12 Remove the USB device from Switch B after the process completes, and repeat the steps to perform the USB Auto Configuration process on Switch C. 404 Auto Image and Configuration Update Enabling DHCP Auto Configuration and Auto Image Download If no USB device is connected to the USB port on the Dell Networking switch and no configuration file is found during the boot process, the Auto Configuration feature uses the DHCP Auto Configuration process to download the configuration file to the switch. This example describes the procedures to complete the configuration. To use DHCP auto configuration: 1 Create a default config file for the switches named host.cfg. For information about creating configuration files, see Managing Images and Files. 2 Upload the host.cfg file to the TFTP server. 3 Upload the image file to the TFTP server. 4 Configure an address pool on the DHCP server that contains the following information: a The IP address (yiaddr) and subnet mask (option 1) to be assigned to the interface b The IP address of a default gateway (option 3) c DNS server address (option 6) d Name of config file for each host e Identification of the TFTP server by hostname (DHCP option 66 or the sname field in the DHCP header) or IP address (DHCP option 150 or the siaddr field in the DHCP header) f Name of the text file (option 125, the V-I vendor-specific Information option) that contains the path to the image file. 5 Connect a port (OOB port for out-of-band management or any switch port for in-band management) on each switch to the network. 6 Boot the switches. Auto Image and Configuration Update 405 Easy Image Upgrade via USB If a USB device is detected during bootup and there is an image on the USB device, and the switch has no startup config file, then the image version is checked against the active image version. If a newer image version is found on the USB device, the image is copied to the switch and the switch reloads using the new image. 1 Copy the startup-config file to the backup-config,; e.g., copy startupconfig backup-config. 2 Delete the startup-config file; e.g., del startup-config. 3 Put the new image on a cleanly formatted USB stick and insert the USB stick into the stack master. 4 Reboot the stack master and skip the Easy Startup configuration wizard by pressing N when prompted. 5 After the upgrade completes, copy the backup-config to the startup-config, remove the USB stick, and reload the stack. The startup configuration is migrated to the new syntax when loaded into the running-config. Check the running-config, make and necessary adjustments, and then save the running-config into the startup-config. 406 Auto Image and Configuration Update Monitoring Switch Traffic 16 This chapter describes sFlow features, Remote Monitoring (RMON), and Port Mirroring features. The topics covered in this chapter include: • Traffic Monitoring Overview • Default Traffic Monitoring Values • Monitoring Switch Traffic (Web) • Monitoring Switch Traffic (CLI) • Traffic Monitoring Configuration Examples Traffic Monitoring Overview The switch maintains statistics about network traffic that it handles. It also has embedded technology that collects and sends information about traffic to other devices. Dell Networking series switches include support for flow-based monitoring through sFlow and Remote Network Monitoring (RMON) agents. What is sFlow Technology? sFlow is an industry standard technology for monitoring high-speed switched and routed networks. Dell Networking N2000, N3000, and N4000 series switches software has a built-in sFlow agent that can monitor network traffic on each port and generate sFlow data to an sFlow receiver (also known as a collector). sFlow helps to provide visibility into network activity, which enables effective management and control of network resources. sFlow is an alternative to the NetFlow network protocol, which was developed by Cisco Systems. The switch supports sFlow version 5. As illustrated in Figure 16-1, the sFlow monitoring system consists of sFlow Agents (such as Dell Networking series switches) and a central sFlow receiver. sFlow Agents use sampling technology to capture traffic statistics from Monitoring Switch Traffic 407 monitored devices. sFlow datagrams forward sampled traffic statistics to the sFlow Collector for analysis. You can specify up to eight different sFlow receivers to which the switch sends sFlow datagrams. Figure 16-1. sFlow Architecture The advantages of using sFlow are: 408 • It is possible to monitor all ports of the switch continuously, with no impact on the distributed switching performance. • Minimal memory/CPU is required. Samples are not aggregated into a flowtable on the switch; they are forwarded immediately over the network to the sFlow receiver. • The sFlow system is tolerant to packet loss in the network because statistical modeling means the loss is equivalent to a slight change in the sampling rate. • sFlow receiver can receive data from multiple switches, providing a realtime synchronized view of the whole network. • The receiver can analyze traffic patterns based on protocols found in the headers (e.g., TCP/IP, IPX, Ethernet, AppleTalk…). This alleviates the need for a layer 2 switch to decode and understand all protocols. Monitoring Switch Traffic sFlow Sampling The sFlow Agent in the Dell Networking software uses two forms of sampling: • Statistical packet-based sampling of switched or routed Packet Flows • Time-based sampling of counters Packet Flow Sampling and Counter Sampling are performed by sFlow Instances associated with individual Data Sources within an sFlow Agent. Both types of samples are combined in sFlow datagrams. Packet Flow Sampling creates a steady, but random, stream of sFlow datagrams that are sent to the sFlow Collector. Counter samples may be taken opportunistically to fill these datagrams. To perform Packet Flow Sampling, an sFlow Sampler Instance is configured with a Sampling Rate. Packet Flow sampling results in the generation of Packet Flow Records. To perform Counter Sampling, an sFlow Poller Instance is configured with a Polling Interval. Counter Sampling results in the generation of Counter Records. sFlow Agents collect Counter Records and Packet Flow Records and send them as sFlow datagrams to sFlow Collectors. Packet Flow Sampling Packet Flow Sampling, carried out by each sFlow instance, ensures that any packet observed at a Data Source has an equal chance of being sampled, irrespective of the Packet Flow(s) to which it belongs. Packet Flow Sampling is accomplished as follows: • A packet arrives on an interface. • The Network Device makes a filtering decision to determine whether the packet should be dropped. • If the packet is not filtered (dropped) a destination interface is assigned by the switching/routing function. • A decision is made on whether or not to sample the packet. The mechanism involves a counter that is decremented with each packet. When the counter reaches zero a sample is taken. • When a sample is taken, the counter indicating how many packets to skip before taking the next sample is reset. The value of the counter is set to a random integer where the sequence of random integers used over time is the Sampling Rate. Monitoring Switch Traffic 409 Counter Sampling The primary objective of Counter Sampling is to efficiently, periodically export counters associated with Data Sources. A maximum Sampling Interval is assigned to each sFlow instance associated with a Data Source. Counter Sampling is accomplished as follows: • sFlow Agents keep a list of counter sources being sampled. • When a Packet Flow Sample is generated the sFlow Agent examines the list and adds counters to the sample datagram, least recently sampled first. Counters are only added to the datagram if the sources are within a short period, 5 seconds say, of failing to meet the required Sampling Interval. • Periodically, say every second, the sFlow Agent examines the list of counter sources and sends any counters that must be sent to meet the sampling interval requirement. The set of counters is a fixed set. What is RMON? Like sFlow, RMON is a technology that enables the collection and analysis of a variety of data about network traffic. Dell Networking N2000, N3000, and N4000 series switches software includes an RMON probe (also known as an RMON agent) that collect information and analyze packets. The data that is collected is defined in the RMON MIB, RFC 2819. RMON is defined in an Internet Engineering Task Force (IETF) specification and is an extension of the SNMP MIB. You can view the RMON information locally on the switch or by using a generic RMON console on a network management station (NMS). SNMP does not need to be configured on the switch to view the RMON data locally. However, if you use a management station to view the RMON data that the switch collects and analyzes, you must configure the following SNMP settings: • Set up the SNMP community string to be used by the SNMP manager at a given IP address. • Specify the network management system IP address or permit management access from all IP addresses. For more information about configuring SNMP, see "Configuring SNMP" on page 323. 410 Monitoring Switch Traffic The RMON agent in the switch supports the following groups: • Group 1—Statistics. Contains cumulative traffic and error statistics. • Group 2—History. Generates reports from periodic traffic sampling that are useful for analyzing trends. • Group 3 —Alarm. Enables the definition and setting of thresholds for various counters. Thresholds can be passed in either a rising or falling direction on existing MIB objects, primarily those in the Statistics group. An alarm is triggered when a threshold is crossed and the alarm is passed to the Event group. The Alarm requires the Event Group. • Group 9 —Event. Controls the actions that are taken when an event occurs. RMON events occur when: – A threshold (alarm) is exceeded – There is a match on certain filters. NOTE: The switch supports RMON1. What is Port Mirroring? Port mirroring is used to monitor the network traffic that a port sends and receives. The Port Mirroring feature creates a copy of the traffic that the source port handles and sends it to a destination port. The source port is the port that is being monitored. The destination port is where you would connect a network protocol analyzer to learn more about the traffic that is handled by the source port. Dell Networking switches support RSPAN destinations where traffic can be tunneled across the operational network. A port monitoring session includes one or more source ports that mirror traffic to a single destination port. Sources can include VLANs, physical interfaces, port-channels, the internal CPU port, or IP or MAC ACL flows. Certain sources are not supported; i.e., physical members of a port-channel, VLANs that contain a LAG member, etc. Destination ports, once configured, no longer participate in spanning tree, IGMP/MLD snooping, or GVRP; do not learn MAC addresses (learned MAC addresses are purged); do not participate in routing (route entries are purged); and do not utilize any static filter configuration. Configuration of a destination port is restored when the port is no longer configured as a destination port. Monitoring Switch Traffic 411 For each source port, you can specify whether to mirror ingress traffic (traffic the port receives, or RX), egress traffic (traffic the port sends, or TX), or both ingress and egress traffic. NOTE: You can create a DiffServ policy class definition or an ACL that mirrors specific types of traffic to a destination port. For more information, see "Configuring Differentiated Services" on page 1285 or "Configuring Access Control Lists" on page 583. The packet that is copied to the destination port is in the same format as the original packet on the wire. This means that if the mirror port is copying a received packet, the copied packet is VLAN tagged or untagged as it was received on the source port. If the mirror is copying a transmitted packet, the copied packet is VLAN tagged or untagged as it is being transmitted on the source port. Destinations include physical interfaces and RSPAN VLANs. After you configure the port mirroring session, you can enable or disable the administrative mode of the session to start or stop the probe port from receiving mirrored traffic. Port Mirroring Behaviors The following behaviors are applicable to monitor ports: 412 • The destination port loses its VLAN configuration when port mirroring is enabled. The VLAN configuration is restored when the port is no longer configured for a monitor session. The mirrored source and the transit ports retain their VLAN configuration. Transit ports must be members of the RSPAN VLAN. • When port mirroring is enabled, all MAC address entries associated with destination ports are purged. This prevents transmitting packets out of the port that are not seen on the mirrored port. If spanning tree is enabled, this is treated as a topology change. • The spanning tree protocol is disabled on destination ports such that frames are always received from or transmitted out of the port as soon as the port is up (spanning tree status is forwarding and role is disabled). This is analogous to always setting the spanning tree state of the port to forwarding. When a port is no longer configured to be the destination port, spanning tree is re-enabled for that port, if configured. Note that the Monitoring Switch Traffic disabling of spanning tree on a destination port means that administrators must only connect the destination port to directly attached probes to avoid the possibility of a network loop. • GVRP is disabled on destination ports such that GVRP PDUs are never received from or transmitted to the port. Dynamic registrations are not allowed on a destination port. The GVRP configuration at the port is maintained and is reapplied when the port is no longer part of the SPAN. • All static filters, both source and destination, are disabled on destination ports. • If routing is enabled on a destination port or an RSPAN VLAN, all route entries associated with that port are purged. From a routing perspective, the interface is marked as down. • Generally, the configuration of the source port is undisturbed so that its behavior remains the same as if it was not mirrored. • Packets locally generated by the switch and transmitted over a source port are not copied in a mirroring session. • The internal CPU port is allowed as a source port for local monitoring sessions only (not allowed for RSPAN). If the internal CPU port is mirrored, packets received and generated by the CPU for all ports are mirrored. Remote Capture The Remote Capture feature enables mirrorring packets transmitted and received by the switch CPU to a remote client for packet analysis using the Wireshark tool. This feature can be used to help diagnose switch behavior or monitor traffic sent to the switch CPU. The capture feature can also be configured to capture to a local file or to an in-memory buffer. Why is Traffic Monitoring Needed? Monitoring the traffic that the switch handles, as well as monitoring all traffic in the network, can help provide information about network performance and utilization. This information can be useful in network planning and resource allocation. Information about traffic flows can also help troubleshoot problems in the network. Monitoring Switch Traffic 413 Default Traffic Monitoring Values The sFlow agent is enabled by default, but sampling and polling are disabled on all ports. Additionally, no sFlow receivers (collectors) are configured. Table 16-1 contains additional default values for the sFlow feature. Table 16-1. sFlow Defaults Parameter Default Value Receiver timeout for sampling 0 Receiver port 6343 Receiver Maximum Datagram Size 1400 bytes Maximum header size 128 bytes RMON is enabled by default, but no RMON alarms, events, or history statistic groups are configured. Port mirroring is disabled, and no ports are configured as source or destination ports. After you configure a port mirroring session, the administrative mode is disabled until you explicitly enable it. Monitoring Switch Traffic (Web) This section provides information about the OpenManage Switch Administrator pages to use to monitor network traffic on a Dell Networking N2000, N3000, and N4000 series switches. For details about the fields on a page, click at the top of the page. sFlow Agent Summary Use the sFlow Agent Summary page to view information about sFlow MIB and the sFlow Agent IP address. To display the Agent Summary page, click System → sFlow → Agent Summary in the navigation panel. 414 Monitoring Switch Traffic Figure 16-2. sFlow Agent Summary Monitoring Switch Traffic 415 sFlow Receiver Configuration Use the sFlow Receiver Configuration page to configure settings for the sFlow receiver to which the switch sends sFlow datagrams. You can configure up to eight sFlow receivers that will receive datagrams. To display the Receiver Configuration page, click System → sFlow → Receiver Configuration in the navigation panel. Figure 16-3. sFlow Receiver Configuration Click Show All to view information about configured sFlow receivers. 416 Monitoring Switch Traffic sFlow Sampler Configuration Use the sFLow Sampler Configuration page to configure the sFlow sampling settings for switch ports. To display the Sampler Configuration page, click System → sFlow → Sampler Configuration in the navigation panel. Figure 16-4. sFlow Sampler Configuration Click Show All to view information about configured sampler data sources. Monitoring Switch Traffic 417 sFlow Poll Configuration Use the sFLow Poll Configuration page to configure how often a port should collect counter samples. To display the Sampler Configuration page, click System → sFlow → Sampler Configuration in the navigation panel. Figure 16-5. sFlow Poll Configuration Click Show All to view information about the ports configured to collect counter samples. 418 Monitoring Switch Traffic Interface Statistics Use the Interface Statistics page to display statistics for both received and transmitted packets. The fields for both received and transmitted packets are identical. To display the page, click Statistics/RMON → Table Views → Interface Statistics in the navigation panel. Figure 16-6. Interface Statistics Monitoring Switch Traffic 419 Etherlike Statistics Use the Etherlike Statistics page to display interface statistics. To display the page, click Statistics/RMON → Table Views → Etherlike Statistics in the navigation panel. Figure 16-7. Etherlike Statistics 420 Monitoring Switch Traffic GVRP Statistics Use the GVRP Statistics page to display switch statistics for GVRP. To display the page, click Statistics/RMON → Table Views → GVRP Statistics in the navigation panel. Figure 16-8. GVRP Statistics Monitoring Switch Traffic 421 EAP Statistics Use the EAP Statistics page to display information about EAP packets received on a specific port. For more information about EAP, see "Configuring Port and System Security" on page 503. To display the EAP Statistics page, click Statistics/RMON → Table Views → EAP Statistics in the navigation panel. Figure 16-9. EAP Statistics 422 Monitoring Switch Traffic Utilization Summary Use the Utilization Summary page to display interface utilization statistics. To display the page, click Statistics/RMON → Table Views → Utilization Summary in the navigation panel. Figure 16-10. Utilization Summary Monitoring Switch Traffic 423 Counter Summary Use the Counter Summary page to display interface utilization statistics in numeric sums as opposed to percentages. To display the page, click Statistics/RMON → Table Views → Counter Summary in the navigation panel. Figure 16-11. 424 Counter Summary Monitoring Switch Traffic Switchport Statistics Use the Switchport Statistics page to display statistical summary information about switch traffic, address tables, and VLANs. To display the page, click Statistics/RMON → Table Views → Switchport Statistics in the navigation panel. Figure 16-12. Switchport Statistics Monitoring Switch Traffic 425 RMON Statistics Use the RMON Statistics page to display details about switch use such as packet processing statistics and errors that have occurred on the switch. To display the page, click Statistics/RMON → RMON → Statistics in the navigation panel. Figure 16-13. 426 RMON Statistics Monitoring Switch Traffic RMON History Control Statistics Use the RMON History Control page to maintain a history of statistics on each port. For each interface (either a physical port or a port-channel), you can define how many buckets exist, and the time interval between each bucket snapshot. To display the page, click Statistics/RMON → RMON → History Control in the navigation panel. Figure 16-14. RMON History Control Adding a History Control Entry To add an entry: 1 Open the RMON History Control page. 2 Click Add. The Add History Entry page displays. Monitoring Switch Traffic 427 Figure 16-15. Add History Entry 3 Select the port or LAG on which you want to maintain a history of statistics. 4 Specify an owner, the number of historical buckets to keep, and the sampling interval. 5 Click Apply to add the entry to the RMON History Control Table. To view configured history entries, click the Show All tab. The RMON History Control Table displays. From this page, you can remove configured history entries. 428 Monitoring Switch Traffic RMON History Table Use the RMON History Table page to display interface-specific statistical network samplings. Each table entry represents all counter values compiled during a single sample. To display the RMON History Table page, click Statistics/RMON → RMON → History Table in the navigation panel. Figure 16-16. RMON History Table Monitoring Switch Traffic 429 RMON Event Control Use the RMON Events Control page to define RMON events. Events are used by RMON alarms to force some action when a threshold is crossed for a particular RMON counter. The event information can be stored in a log and/or sent as a trap to a trap receiver. To display the page, click Statistics/RMON → RMON → Event Control in the navigation panel. Figure 16-17. RMON Event Control Adding an RMON Event To add an event: 1 Open the RMON Event Control page. 2 Click Add. The Add an Event Entry page displays. 430 Monitoring Switch Traffic Figure 16-18. Add an Event Entry 3 If the event sends an SNMP trap, specify the SNMP community to receive the trap. 4 Optionally, provide a description of the event and the name of the event owner. 5 Select an event type. 6 Click Apply. The event is added to the RMON Event Table, and the device is updated. Viewing, Modifying, or Removing an RMON Event To manage an event: 1 Open the RMON Event Control page. 2 Click Show All to display the Event Control Table page. 3 To edit an entry: a Select the Edit check box in for the event entry to change. b Modify the fields on the page as needed. 4 To remove an entry, select the Remove check box in for the event entry to remove. 5 Click Apply. Monitoring Switch Traffic 431 RMON Event Log Use the RMON Event Log page to display a list of RMON events. To display the page, click Statistics/RMON → RMON → Events Log in the navigation panel. Figure 16-19. 432 RMON Event Log Monitoring Switch Traffic RMON Alarms Use the RMON Alarms page to set network alarms. Alarms occur when certain thresholds are crossed for the configured RMON counters. The alarm triggers an event to occur. The events can be configured as part of the RMON Events group. For more information about events, see "RMON Event Log" on page 432. To display the page, click Statistics/RMON → RMON → Alarms in the navigation panel. Figure 16-20. RMON Alarms Monitoring Switch Traffic 433 Adding an Alarm Table Entry To add an alarm: 1. Open the RMON Alarms page. 2. Click Add. The Add an Alarm Entry page displays. Figure 16-21. Add an Alarm Entry 3. Complete the fields on this page as needed. Use the help menu to learn more information about the data required for each field. 4. Click Apply. The RMON alarm is added, and the device is updated. To view configured alarm entries, click the Show All tab. The Alarms Table displays. From this page, you can remove configured alarms. 434 Monitoring Switch Traffic Port Statistics Use the Port Statistics page to chart port-related statistics on a graph. To display the page, click Statistics/RMON → Charts → Port Statistics in the navigation panel. Figure 16-22. Ports Statistics To chart port statistics, select the type of statistics to chart and (if desired) the refresh rate, then click Draw. Monitoring Switch Traffic 435 LAG Statistics Use the LAG Statistics page to chart LAG-related statistics on a graph. To display the page, click Statistics/RMON → Charts → LAG Statistics in the navigation panel. Figure 16-23. LAG Statistics To chart LAG statistics, select the type of statistics to chart and (if desired) the refresh rate, then click Draw. 436 Monitoring Switch Traffic Port Mirroring Use the Port Mirroring page to create a mirroring session in which all traffic that is sent or received (or both) on one or more source ports is mirrored to a destination port. To display the Port Mirroring page, click Switching → Ports → Traffic Mirroring → Port Mirroring in the navigation panel. Figure 16-24. Port Mirroring Configuring a Port Mirror Session To configure port mirroring: 1 Open the Port Mirroring page. 2 Click Add. The Add Source Port page displays. 3 Select the port to be mirrored. 4 Select the traffic to be mirrored. Monitoring Switch Traffic 437 Figure 16-25. Add Source Port 5 Click Apply. 6 Repeat the previous steps to add additional source ports. 7 Click Port Mirroring to return to the Port Mirroring page. 8 Enable the administrative mode and specify the destination port. Figure 16-26. Configure Additional Port Mirroring Settings 9 Click Apply. 438 Monitoring Switch Traffic Monitoring Switch Traffic (CLI) This section provides information about the commands you use to manage traffic monitoring features on the switch and to view information about switch traffic. For more information about these commands, see the Dell Networking N2000, N3000, and N4000 Series Switches CLI Reference Guide at support.dell.com/manuals. Configuring sFlow Beginning in Privileged EXEC mode, use the following commands to configure the sFlow receiver and to configure the sampling and polling on switch interfaces. Command Purpose configure Enter Global Configuration mode sflow rcvr_index destination ip-address [port] Configure the address of the sFlow receiver and (optionally) the destination UDP port for sFlow datagrams. • rcvr_index—The index of this sFlow receiver (Range: 1–8). • ip-address—The sFlow receiver IP address. • port —The destination Layer 4 UDP port for sFlow datagrams. (Range: 1–65535). sflow rcvr_index destination owner owner_string timeout timeout sflow rcvr_index maxdatagram size Specify the identity string of the receiver and set the receiver timeout value. timeout—The number of seconds the configuration will be valid before it is automatically cleared. A value of 0 essentiality means the receiver is not configured. Specify the maximum number of data bytes that can be sent in a single sample datagram. The receiver should also be set this value to avoid fragmentation of the sFlow datagrams. (Range: 200–9116 bytes). Monitoring Switch Traffic 439 Command Purpose sflow rcvr-index polling Enable a new sFlow poller instance on an interface range. if_type if_number pollinterval • rcvr-index — The sFlow Receiver associated with the poller (Range: 1–8). • if_type if_number — The list of interfaces to poll. The interface type can be Gigabitethernet (gi) or Tengigabitethernet (te), for example te1/0/3-5 enables polling on ports 3, 4, and 5. • poll-interval — The sFlow instance polling interval. A value of n means once in n seconds a counter sample is generated. (Range: 0–86400). sflow rcvr-index sampling if_type Enable a new sflow sampler instance for the specified interface range. if_number sampling-rate • rcvr-index — The sFlow Receiver for this sFlow sampler [size] to which flow samples are to be sent. • if_type if_number — The list of interfaces to sample. The interface type can be Gigabitethernet (gi) or Tengigabitethernet (te), for example te1/0/3-5 enables polling on ports 3, 4, and 5. • sampling-rate — The statistical sampling rate for packet sampling from this source. A sampling rate of 1 counts all packets. A value of n means that out of n incoming packets, 1 packet will be sampled. (Range: 1024 - 65536). • size — The maximum number of bytes that should be copied from the sampler packet (Range: 20 - 256 bytes). interface interface Enter interface configuration mode for the specified interface. The interface variable includes the interface type and number, for example tengigabitethernet 1/0/3 or te1/0/3. You can also specify a range of interfaces with the interface range command, for example, interface range tengigabitethernet 1/0/8-12 configures interfaces 8, 9, 10, 11, and 12. sflow rcvr-index polling poll-interval 440 Enable a new sFlow poller instance for the interface. Monitoring Switch Traffic Command Purpose sflow rcvr-index sampling Enable a new sflow sampler instance for the interface. sampling-rate [size] CTRL + Z Exit to Privileged Exec mode. show sflow agent View information about the switch sFlow agent. show sflow index destination View information about a configured sFlow receivers. show sflow index polling View information about the configured sFlow poller instances for the specified receiver. show sflow index sampling View information about the configured sFlow sampler instances for the specified receiver. Configuring RMON Beginning in Privileged EXEC mode, use the following commands to configure RMON alarms, collection history, and events. The table also lists the commands you use to view information collected by the RMON probe. Command Purpose configure Enter Global Configuration mode rmon event number [log] [trap community] [description string] [owner string] Configure an RMON event. • number — The event index. (Range: 1–65535) • log — Specify that an entry is made in the log table for each event. • trap community — If the event is an SNMP trap to be sent, it is sent to the SNMP community specified by this octet string. (Range: 0-127 characters) • description string — A comment describing this event. (Range 0-127 characters) • owner string — Enter a name that specifies who configured this event. If unspecified, the name is an empty string. Monitoring Switch Traffic 441 Command Purpose rmon alarm number variable interval Add an alarm entry • number — The alarm index. (Range: 1–65535) {absolute |delta} risingthreshold value [event- • variable — A fully qualified SNMP object identifier that resolves to a particular instance of an MIB object. number] risingthreshold value [event- • interval — The interval in seconds over which the data is number] [startup sampled and compared with the rising and falling direction] [owner string] thresholds. (Range: 1–4294967295) • rising-threshold value — Rising threshold value. (Range: 0–4294967295) • rising-threshold value — Falling threshold value. (Range: 0–4294967295) • event-number — The index of the event that is used when a rising or falling threshold is crossed. (Range: 165535) • delta — The sampling method for the selected variable and calculating the value to be compared against the thresholds. If the method is delta, the selected variable value at the last sample is subtracted from the current value, and the difference compared with the thresholds. • absolute — The sampling method for the selected variable and calculating the value to be compared against the thresholds. If the method is absolute, the value of the selected variable is compared directly with the thresholds at the end of the sampling interval. • startup direction — The type of startup alarm, which can be rising, falling, or rising-falling. • owner string — Enter a name that specifies who configured this alarm. interface interface 442 Enter Interface Configuration mode for the specified port or LAG. Monitoring Switch Traffic Command Purpose rmon collection history index [owner ownername] [buckets bucket-number] [interval seconds] Enable an RMON MIB history statistics group on the interface. NOTE: You must configure RMON alarms and events before RMON collection history is able to display. • index — The requested statistics index group. (Range: 1–65535) • ownername — Records the RMON statistics group owner name. If unspecified, the name is an empty string. • bucket-number — A value associated with the number of buckets specified for the RMON collection history group of statistics. If unspecified, defaults to 50. (Range: 1 - 65535) • seconds — The number of seconds in each polling cycle. If unspecified, defaults to 1800. (Range: 1–3600) CTRL + Z Exit to Privileged EXEC mode. show rmon {alarms |collection history | events | history | log | statistics} View information collected by the RMON probe. Viewing Statistics Use the following commands in Privileged EXEC mode to view statistics about the traffic handled by the switch. Command Purpose show interfaces counters Display the error counters or number of octets and packets [errors][{interface | handled by all interfaces or the specified interface. port-channel}] Display detailed statistics for a specific port or LAG, or for show statistics {switchport | interface} the entire switch. The interface variable includes the interface type and number. Monitoring Switch Traffic 443 Configuring Port Mirroring Use the following commands in Privileged EXEC mode to configure a port mirroring session. Command Purpose configure Enter Global Configuration mode monitor session Configure a source (monitored) port or CPU interface for session_number source a monitor session. interface {interface} [rx • session_number —The monitoring session ID, which is | tx | both] always 1. • interface—The interface to be monitored. • rx | tx — Monitor ingress (rx) or egress (tx) traffic. If no parameter is given, both ingress and egress traffic are monitored. monitor session Configure a destination (probe) port for a monitor session. destination interface • session_number —The monitoring session ID, which is always 1. session_number interface • interface—The Ethernet interface to which the monitored source traffic is copied. monitor session session_number mode Enable the administrative mode for the configured port mirroring session to start sending the traffic from the source port to the destination (probe) port. exit Exit to Privileged EXEC mode. show monitor session 1 View information about the configured port mirroring session. 444 Monitoring Switch Traffic Configuring RSPAN RSPAN is an extension of port mirroring that operates across multiple switches. Use the following commands in Privileged EXEC mode to configure RSPAN. Remember to assign VLANs to physical interfaces (steps not shown). Configuring RSPAN (Source Switch) Command Purpose configure Enter Global Configuration mode. vlan vlan-id Configure an RSPAN VLAN. remote-span Configure the VLAN as a spanning VLAN. exit Exit to Global Configuration mode. interface te1/0/1 Enter interface configuration mode. switchport mode trunk Set the egress span interface to trunk mode. switch trunk allowed vlan vlan-id Restrict the trunk to the spanning VLAN (optional). exit Exit to Global Configuration mode. Configure a source (monitored) port for a monitor session. monitor session session_number source • session_number —The monitoring session ID, which is interface interface [{rx | always 1. tx | both}] • sourceinterface—The interface to be monitored. The internal CPU port may not be configured as an RSPAN source. • rx | tx | both — Monitor ingress (rx) or egress (tx) traffic. If no parameter is given, both ingress and egress traffic are monitored. monitor session Configure a local RSPAN reflector port on the source session_number switch. The reflector port should be configured as a trunk destination remote vlan port. vlan_id reflector-port interface_id monitor session session_number mode Enable the administrative mode for the configured port mirroring session to start sending the traffic from the source port to the destination (probe) port. Monitoring Switch Traffic 445 Command Purpose exit Exit to Privileged EXEC mode. Configuring RSPAN (Transit Switch) Command Purpose configure Enter Global Configuration mode. vlan vlan-id Create an RSPAN VLAN. remote-span Configure the VLAN as a spanning VLAN. exit Exit to Global Configuration mode. interface range te1/0/1-2 Configure the span interfaces. switchport mode trunk Configure the interface to be in trunking mode. switch trunk allowed vlan vlan-id Restrict the trunk to the spanning VLAN (optional). exit Exit to Global Configuration mode. Configuring RSPAN (Destination Switch) Command Purpose configure Enter Global Configuration mode. vlan vlan-id Create an RSPAN VLAN. remote-span Configure the VLAN as a spanning VLAN. exit Exit to Global Configuration mode monitor session Configure a source RSPAN VLAN on the destination monitor session Configure the destination port on the RSPAN destination switch. monitor session Enable the monitor session. session_id source remote switch. vlan vlan_id session_id destination interface interface session_id mode 446 Monitoring Switch Traffic Traffic Monitoring Configuration Examples This section contains the following examples: • Configuring sFlow • Configuring RMON • Configuring Remote Capture • Configuring RSPAN Configuring sFlow This example shows how to configure the switch so that ports 10-15 and port 23 send sFlow datagrams to an sFlow receiver at the IP address 192.168.20.34. The receiver owner is receiver1, and the timeout is 100000 seconds. A counter sample is generated on the ports every 60 seconds (polling interval), and 1 out of every 8192 packets is sampled. Note that sFlow monitoring is not enabled until a receiver owner string is configured. To configure the switch: 1 Configure information about the sFlow receiver. console#configure console(config)#sflow 1 destination 192.168.30.34 console(config)#sflow 1 destination owner receiver1 timeout 100000 2 Configure the polling and sampling information for Tengigabit Ethernet ports 10-20. console(config)#sflow 1 polling te1/0/10-15 60 console(config)#sflow 1 sampling te1/0/10-15 8192 3 Configure the polling and sampling information for Tengigabit Ethernet port 23. console(config)#interface te1/0/23 console(config-if-Te1/0/23)#sflow 1 polling 60 console(config-if-Te1/0/23)#sflow 1 sampling 8192 4 Verify the configured information. console#show sflow 1 destination Receiver Index.................... 1 Monitoring Switch Traffic 447 Owner String...................... Time out.......................... IP Address:....................... Address Type...................... Port.............................. Datagram Version.................. Maximum Datagram Size............. receiver1 99994 192.168.30.34 1 6343 5 1400 console#show sflow 1 polling Poller Data Source ----------Te1/0/10 Te1/0/11 Te1/0/12 Te1/0/13 Te1/0/14 Te1/0/15 Te1/0/23 Receiver Index ------1 1 1 1 1 1 1 Poller Interval ------60 60 60 60 60 60 60 console#show sflow 1 sampling Sampler Data Source ----------Te1/0/10 Te1/0/11 Te1/0/12 Te1/0/13 Te1/0/14 Te1/0/15 Te1/0/23 448 Receiver Index ------1 1 1 1 1 1 1 Monitoring Switch Traffic Packet Sampling Rate ------------8192 8192 8192 8192 8192 8192 8192 Max Header Size ---------128 128 128 128 128 128 128 Configuring RMON This example generates a trap and creates a log entry when the number of inbound packets are undeliverable due to errors increases by 20 or more. First, an RMON event is created. Then, the alarm is created. The event (event 1) generates a trap and creates a log entry. The alarm is configured for the MIB object ifInErrors (OID: 1.3.6.1.2.1.2.2.1.14.1). The OID is the variable. The alarm checks the variable every 30 seconds to compare the MIB counter to the configured rising and falling thresholds. If the rise is equal to or greater than 20, event 1 goes into effect. To configure the switch: 1 Create the event. The trap is sent to the private SNMP community. console#configure console(config)#rmon event 1 description "emergency event" log trap private 2 Create the alarm. console(config)#rmon alarm 1 1.3.6.1.2.1.2.2.1.14.1 30 delta rising-threshold 20 1 falling-threshold 1 3 Verify the configuration. console#show rmon events Index Description Type Community Owner Last time sent ------------------------------------------------------------1 emergency log-trap private 0 days 0h:0m:0s event console#show rmon alarms Index OID Owner ---------------------------------------------1 1.3.6.1.2.1.2.2.1.14.1 Monitoring Switch Traffic 449 Configuring Remote Capture This example configures the switch to mirror packets transmitted and received by the switch CPU to a Wireshark client. This is useful to diagnose switch behavior and to determine if an attached device is sending properly formatted packets with correct information to the switch, or just to monitor traffic sent to the switch CPU. The capture feature can also be configured to capture to a local file in pcap format or to capture to an in-memory buffer (text format). 1 Configure capture for Wireshark remote access on port 2002. console(config)#monitor capture remote console(config)#exit 2 Start the capture enabling capture of both transmitted and received packets. console# monitor capture start all 3 Configure Wireshark for remote capture by selecting Capture > Interfaces from the top tab. (The screens shown in this example are from Wireshark 1.10.1.) 4 On the Capture Interfaces dialog, click Options. 450 Monitoring Switch Traffic 5 On the Capture Options dialog, click Manage Interfaces. Monitoring Switch Traffic 451 6 Add a new interface by giving the switch IP address and the default remote port (2002). First, select the Remote Interfaces tab and click Add. 7 Enter the switch IP address and port (2002). Choose Null authentication (default). 452 Monitoring Switch Traffic 8 Click OK to accept the entry. 9 On the Add new interfaces dialog, click Apply and then click Close. Monitoring Switch Traffic 453 10 From the Wireshark:Capture Options dialog, select the remote switch and click Start. Remote Capture Caveats Remote capture over an in-band port captures the capture packets transmitted to the Wireshark client. Therefore, when using remote capture over an in-band port, it is best to configure remote capture to capture only received packets, to configure remote capture to operate over the out-of-band port, or to configure local capture to capture to the in-memory buffer or a local pcap file. 454 Monitoring Switch Traffic Configuring RSPAN RSPAN supports the transport of mirrored packets across the network to a remote switch. Ports may be configured as source ports, intermediate ports, or destination ports. RSPAN Source Switch This example mirrors interface gi1/0/3 to VLAN 723. VLAN 723 is the selected transit VLAN. Administrators should reserve a VLAN as the RSPAN VLAN when designing their network. The source switch requires a reflector port to carry packets to the transit switch. The reflector port must be configured as trunk port. Untagged packets on the source port are transmitted on the RSPAN VLAN tagged with the RSPAN VLAN. Tagged packets on the source port are transmitted over the RPSAN VLAN double-tagged with the outer tag containing the RSPAN VLAN. The last line in this configuration enables the monitor session. It is recommended that configuration proceed with the destination switch first, followed by the intermediate switches, and then by the source switch. 1 Configure RSPAN on VLAN 723: console#configure console(config)#vlan 723 console(config-vlan723)#remote-span console(config-vlan723)#exit 2 Configure interface te1/0/1 as the reflector port in trunk mode: console(config)#interface te1/0/1 console(config-if-Te1/0/1)#switchport mode trunk console(config-if-Te1/0/1)#switchport trunk allowed vlan 723 console(config-if-Te1/0/1)#exit 3 Configure a mirroring session with a source port gi1/0/3, the destination VLAN 723, and reflector port te1/0/1: console(config)# monitor session 1 source interface gi1/0/3 console(config)# monitor session 1 destination remote vlan 723 reflector-port te1/0/1 Monitoring Switch Traffic 455 4 Enable the monitor session: console(config)#monitor session 1 mode RSPAN cannot use the CPU as a mirror source. Instead, configure remote capture to view packets sent to or from the switch CPU. RSPAN Transit Switch The following is an example of an RSPAN transit switch configuration. The RSPAN VLAN should be configured as a remote-span in order to disable MAC learning on the VLAN. In this case, the transit switch ports are configured as trunk ports (members of all VLANs) and may be used by other traffic. Packets on the transit switch (in this example) are received and transmitted tagged. 1 Configure remote span on a VLAN: console#configure console(config)#vlan 723 console(config-vlan723)#remote-span console(config-vlan723)#exit 2 Configure the transit switch ports in trunk mode: console(config)#interface te1/0/1 console(config-if-Te1/0/1)#switchport mode trunk console(config-if-Te1/0/1)#interface te1/0/2 console(config-if-Te1/0/2)#switchport mode trunk RSPAN Destination Switch The following example shows the configuration of the RSPAN destination switch. The RSPAN mirrored packets are transmitted over the destination port untagged. 1 Configure remote span on VLAN 723: console#configure console(config)#vlan 723 console(config-vlan723)#remote-span console(config-vlan723)#exit 2 Configure interface te1/0/1 as the destination port. console(config)#interface te1/0/1 456 Monitoring Switch Traffic console(config-if-Te1/0/1)#switchport mode trunk console(config-if-Te1/0/1)#switchport trunk allowed vlan 723 console(config-if-Te1/0/1)#exit 3 Configure a mirroring session with the remote VLAN 723 as the source and inteface gi1/0/1 as the destination port: console(config)#monitor session 1 source remote vlan 723 console(config)#monitor session 1 destination interface gi1/0/1 4 Enable the mirroring session: console(config)#monitor session 1 mode Monitoring Switch Traffic 457 458 Monitoring Switch Traffic 17 Configuring iSCSI Optimization NOTE: This feature is not available on N2000 switches. This chapter describes how to configure Internet Small Computer System Interface (iSCSI) optimization, which enables special quality of service (QoS) treatment for iSCSI traffic. The topics covered in this chapter include: • iSCSI Optimization Overview • Default iSCSI Optimization Values • Configuring iSCSI Optimization (Web) • Configuring iSCSI Optimization (CLI) • iSCSI Optimization Configuration Examples iSCSI Optimization Overview iSCSI optimization provides a means of monitoring iSCSI sessions and iSCSI traffic on the switch. This is accomplished by monitoring, or “snooping,” traffic to detect packets used by iSCSI stations to establish iSCSI sessions and connections. Data from these exchanges may optionally be used to create classification rules to assign traffic between the stations to a configured traffic class. The traffic classification affects how the packets in the flow are queued and scheduled for egress on the destination port. Configuring iSCSI Optimization 459 What Does iSCSI Optimization Do? In networks containing iSCSI initiators and targets, iSCSI Optimization helps to monitor iSCSI sessions or give iSCSI traffic preferential QoS treatment. Dynamically-generated classifier rules generated by snooping iSCSI traffic are used to direct iSCSI data traffic to queues that can be given the desired preference characteristics over other data traveling through the switch. This may help to avoid session interruptions during times of congestion that would otherwise cause iSCSI packets to be dropped. However, in systems where a large proportion of traffic is iSCSI, it may also interfere with other network control-plane traffic, such as ARP or LACP. The preferential treatment of iSCSI traffic needs to be balanced against the needs of other critical data in the network. How Does the Switch Detect iSCSI Traffic Flows? The switch snoops iSCSI session establishment (target login) and termination (target logout) packets by installing classifier rules that trap iSCSI protocol packets to the CPU for examination. Devices that initiate iSCSI sessions generally use well-known TCP ports 3260 or 860 to contact targets. When iSCSI optimization is enabled, by default the switch identifies IP packets to or from these ports as iSCSI session traffic. In addition, the switch separately tracks connections associated with a login session (ISID) (dynamically allocated source/destination TCP port numbers). You can configure the switch to monitor traffic for additional port numbers or port number-target IP address combinations, and you can remove the well-known port numbers from monitoring. You can also associate a target name with a configured target TCP port entry. How Is Quality of Service Applied to iSCSI Traffic Flows? The iSCSI CoS mode is configurable and controls whether CoS queue assignment and/or packet marking is performed on iSCSI traffic. When the iSCSI CoS mode is enabled, the CoS policy is applied to packets in detected iSCSI sessions. In addition, if DCBX is enabled (on N4000 switches only), the iSCSI application priority TLV is generated by the switch. When the iSCSI CoS mode is disabled, iSCSI sessions and connections are detected and shown in the status tables, but no CoS policy is applied to packets. 460 Configuring iSCSI Optimization On N4000 switches, when the iSCSI CoS mode is disabled, the DCBX iSCSI Application Priority TLV is not generated by the switch. In either case, if DCBX is enabled and ports are configured as auto-up or auto-down, the Application Priority TLVs received from the configuration source are proxied to the other ports and, on the N4000 series switches, the CoS policy for iSCSI received via DCBX is applied to iSCSI packets. When iSCSI CoS mode is enabled, iSCSI login sessions up to the switch limits are tracked, and data packets for those sessions are given the configured CoS treatment. iSCSI sessions in excess of the switch limits are not given the configured CoS treament; therefore, it is not advisable to exceed the iSCSI session limit. Multiple connections within a session are counted against the session limit, even though they show in the session table as a single session. In the switch, iSCSI connections are aged out using the session aging timer. If the connection has no detected data packets during the timeout period, the connection is deleted from the switch internal session table. When all connections associated with a session age out or disconnect, the session is deleted. You can configure whether the iSCSI optimization feature uses the VLAN priority or IP DSCP mapping to determine the traffic class queue. By default, iSCSI flows are assigned to the highest VLAN priority tag or DSCP value mapped to the highest queue not used for stack management or voice VLAN. Use the classofservice dot1p-mapping command or the Quality of Service → Class of Service → Mapping Table Configuration page to configure the relevant Class of Service parameters for the queue in order to complete the setting. You can configure whether iSCSI frames are remarked to contain the configured VLAN priority tag or IP DSCP when forwarded through the switch. How Does iSCSI Optimization Use ACLs? iSCSI Optimization borrows ACL lists from the global system pool. ACL lists allocated by iSCSI Optimization reduce the total number of ACLs available for use by the network operator. Enabling iSCSI Optimization uses one ACL list to monitor for iSCSI sessions. Each monitored iSCSI session utilizes two rules from additional ACL lists up to a maximum of two ACL lists. This means that the maximum number of ACL lists allocated by iSCSI is three. Configuring iSCSI Optimization 461 What Information Does the Switch Track in iSCSI Traffic Flows? Packets are examined to find the following data, which is used in tracking the session and creating the classifier entries that enable QoS treatment: • Initiator's IP Address • Target's IP Address • ISID (Initiator defined session identifier) • Initiator's IQN (iSCSI Qualified Name) • Target's IQN • Initiator's TCP Port • Target's TCP Port If no iSCSI traffic is detected for a session for a configurable aging period, the session data is cleared. 462 Configuring iSCSI Optimization How Does iSCSI Optimization Interact With Dell EqualLogic Arrays? The iSCSI feature includes auto-provisioning support with the ability to detect directly connected Dell EqualLogic (EQL) SAN storage arrays and automatically reconfigure the switch to enhance storage traffic flows. The Dell Networking series switches use LLDP, a vendor-neutral protocol, to discover Dell EQL devices on the network. LLDP is enabled by default. For more information about LLDP, see "Discovering Network Devices" on page 761. When the switch detects a Dell EQL array, the following actions occur: • An MTU of 9216 is enabled on the system, if it is not already enabled. • Spanning tree portfast is enabled on the EQL-connected interface identified by LLDP. • Unicast storm control is disabled on the EQL-connected interface identified by LLDP. It is advisable to enable spanning tree portfast and disable unicast storm control on ports connected to the initiators as well. If the iSCSI CoS policy feature is enabled on the switch and an EQL array is detected, the switch applies additional iSCSI CoS policies to the EQL interarray traffic on TCP ports 9876 and 25555. If the iSCSI CoS policy is disabled and EQL arrays are present, the additional CoS policy is removed globally. What Occurs When iSCSI Optimization Is Enabled or Disabled? When iSCSI is enabled on the switch, the following actions occur: • Flow control is globally enabled, if it is not already enabled. • iSCSI session snooping is enabled • iSCSI LLDP monitoring starts to automatically detect Dell EqualLogic arrays. If the iSCSI feature is disabled on the switch, iSCSI resources are released and the detection of Dell EqualLogic arrays by using LLDP is disabled. Disabling iSCSI does not remove the MTU, flow control, portfast or storm control configuration applied as a result of enabling iSCSI. iSCSI Optimization is enabled by default. Configuring iSCSI Optimization 463 How Does iSCSI Optimization Interact with DCBx? NOTE: The DCBx feature is available on the N4000 switches only. The Data Center Bridging Exchange (DCBx) component supports the reception, decoding, and transmission of the Application Priority TLV. In general, if the Application Priority TLV has been received from the configuration source, it will be transmitted to the other auto configuration ports. The DCBx component contains a control to generate the Application Priority TLV for iSCSI if it is not already present in the DCBX information. DCBx generates an Application Priority TLV whenever the following conditions are met: • An EqualLogic array has been detected on the port • iSCSI CoS is enabled using a VPT value The generated Application Priority TLV will contain the following values (in addition to any other information contained in the TLV): • AE Selector=14 • AE Protocol=3260 • AE Priority=priority configured for iSCSI PFC by the iscsi cos vpt command (default priority is 4) The existing application priority entries being transmitted, if any, will not be disturbed. NOTE: If it is desired to utilize DCBX to configure lossless transport of iSCSI using PFC, the operator MUST configure a non-default VLAN end-to-end in order to transport the VLAN priority tag and ensure proper COS treatment on every network enabled device, including CNAs and the EQL arrays. How Does iSCSI Optimization Interact with Dell Compellent Arrays? Dell Networking switches support a macro that may be used to configure a port connected to a Dell Compellent storage array. The name of the macro is profile-compellent-nas. The macro takes a single argument: the interface identifier to which the Dell Compellent array is connected. The macro disables unicast storm control and sets the spanning tree configuration on the port to portfast. For an example of how to execute the macro, see 464 Configuring iSCSI Optimization "Configuring iSCSI Optimization Between Servers and a Disk Array" on page 473. iSCSI CoS and Priority Flow Control/Enhanced Transmission Selection Interactions NOTE: The ETS feature is available on the N4000 switches only. When manually or automatically enabling the classification of iSCSI flows on N4000 series switches, enabling iSCSI CoS is not recommended unless required as follows. When using manual configuration of the switch or auto-configuration via DCBX, the iSCSI packets are classified based on the user priority present in the VLAN tag and, in this case, enabling iSCSI CoS classification via the iSCSI command set provides no benefit. The only case for enabling iSCSI CoS prioritization is when using N4000 series switches to originate iSCSI configuration information via DCBX. In this case, enabling iSCSI CoS classification configures the N4000 switch to generate the iSCSI TLV via DCBX in support of configuring directly connected storage and initiator devices. N4000 series switches support both ETS and DCBx and support DCB configuration in conjunction with EQL devices. Configuring iSCSI Optimization 465 Default iSCSI Optimization Values Table 17-1 shows the default values for the iSCSI optimization feature. Table 17-1. iSCSI Optimization Defaults Parameter Default Value iSCSI optimization global status Enabled iSCSI CoS mode Disabled Jumbo frames Disabled Spanning tree portfast Disabled Unicast storm control Disabled Classification iSCSI packets are classified by VLAN instead of by DSCP values. VLAN priority tag iSCSI flows are assigned by default the highest 802.1p VLAN priority tag mapped to the highest queue not used for stack management or the voice VLAN. DSCP When DSCP is selected as the classification, iSCSI flows are assigned by default the highest DSCP tag mapped to the highest queue not used for stack management or the voice VLAN. Remark Not enabled iSCSI session aging time 10 minutes iSCSI optimization target ports iSCSI well-known ports 3260 and 860 are configured as default (with no IP address or name) but can be removed as any other configured target. 466 Configuring iSCSI Optimization Configuring iSCSI Optimization (Web) This section provides information about the OpenManage Switch Administrator pages to use to the iSCSI features on a Dell Networking N2000, N3000, and N4000 series switches. For details about the fields on a page, click at the top of the page. iSCSI Global Configuration Use the Global Configuration page to allow the switch to snoop for iSCSI sessions/connections and to configure QoS treatment for packets where the iSCSI protocol is detected. To access the iSCSI Global Configuration page, click System → iSCSI → Global Configuration in the navigation panel. Figure 17-1. iSCSI Global Configuration Configuring iSCSI Optimization 467 iSCSI Targets Table Use the Targets Table page to view and configure iSCSI targets on the switch. To access the Targets Table page, click System → iSCSI → Targets in the navigation panel. Figure 17-2. iSCSI Targets Table To add an iSCSI Target, click Add at the top of the page and configure the relevant information about the iSCSI target. Figure 17-3. Add iSCSI Targets 468 Configuring iSCSI Optimization iSCSI Sessions Table Use the Sessions Table page to view summary information about the iSCSI sessions that the switch has discovered. An iSCSI session occurs when an iSCSI initiator and iSCSI target communicate over one or more TCP connections. The maximum number of iSCSI sessions is 192. Redundant (MPIO paths) may not be accounted for in the iSCSI sessions table if a separate iSCSI login is not issued during establishment of the session. To access the Sessions Table page, click System → iSCSI → Sessions Table in the navigation panel. Figure 17-4. iSCSI Sessions Table Configuring iSCSI Optimization 469 iSCSI Sessions Detailed Use the Sessions Detailed page to view detailed information about an iSCSI sessions that the switch has discovered. To access the Sessions Detailed page, click System → iSCSI → Sessions Detailed in the navigation panel. Figure 17-5. iSCSI Sessions Detail 470 Configuring iSCSI Optimization Configuring iSCSI Optimization (CLI) This section provides information about the commands you use to configure iSCSI settings on the switch. For more information about the commands, see the Dell Networking N2000, N3000, and N4000 Series Switches CLI Reference Guide at support.dell.com/manuals. Command Purpose configure Enter Global Configuration mode. iSCSI optimization is enabled by default. iscsi target port tcp-port-1 [tcp-port-2...tcp-port-16] [address ip-address] [name targetname] Configure an iSCSI target port and, optionally, address and name. • tcp-port-n—TCP port number or list of TCP port numbers on which the iSCSI target listens to requests. Up to 16 TCP ports can be defined in the system in one command or by using multiple commands. • ip-address—IP address of the iSCSI target. When the no form of this command is used, and the tcp port to be deleted is one bound to a specific IP address, the address field must be present. • targetname—iSCSI name of the iSCSI target. The name can be statically configured; however, it can be obtained from iSNS or from sendTargets response. The initiator must present both its iSCSI Initiator Name and the iSCSI Target Name to which it wishes to connect in the first login request of a new session or connection. Configuring iSCSI Optimization 471 Command Purpose iscsi cos {enable | disable | Optionally set the quality of service profile that will vtp vtp | dscp dscp [remark] be applied to iSCSI flows. • enable—Enables application of preferential QoS treatment to iSCSI frames. On switches that support DCBX, this also enables the generation of the Application Priority TLV for iSCSI. • disable—Disables application of preferential QoS treatment to iSCSI frames. • vpt/dscp—The VLAN Priority Tag or DSCP value to assign received iSCSI session packets. • remark—Mark the iSCSI frames with the configured DSCP value when egressing the switch. iscsi aging time time Optionally set aging time (range: 1–43,200 seconds) for iSCSI connections. When all connections associated with a session are aged out, the session is deleted. exit Exit to Privilege Exec mode. show iscsi Display iSCSI settings. show iscsi sessions Display iSCSI session information. Redundant (MPIO paths) may not be accounted for in the iSCSI sessions table if a separate iSCSI login is not issued during establishment of the session. 472 Configuring iSCSI Optimization iSCSI Optimization Configuration Examples iSCSI optimization is enabled by default with the appropriate settings to operate properly is almost all configurations. However, you find it necessary to alter those settings, the following procedure illustrates the configuration steps required. Configuring iSCSI Optimization Between Servers and a Disk Array Figure 17-6 illustrates a stack of three Dell Networking series switches connecting two servers (iSCSI initiators) to a disk array (iSCSI targets). An iSCSI application running on the management unit (the top unit in the diagram) has installed priority filters to ensure that iSCSI traffic that is part of these two sessions receives priority treatment when forwarded in hardware. Figure 17-6. iSCSI Optimization Configuring iSCSI Optimization 473 The following commands show how to configure the iSCSI example depicted in Figure 17-6. Remember that iSCSI optimization is enabled by default. 1 Set the system MTU to 9216 to enable the use of jumbo frames. console#config console(config)#system jumbo mtu 9216 2 Optionally configure the switch to associate CoS queue 5 with detected iSCSI session traffic. console(config)#iscsi cos enable console(config)#exit The default target port and IP address criteria is used to determine which packets are snooped for iSCSI session data (ports 860 and 3260; any IP address). 3 If the array is a Compellent storage array, execute the Compellent macro on the ports attached to the array: console#config console(config)#macro global apply profile-compellent-nas $interface_name te1/0/21 console(config)#macro global apply profile-compellent-nas $interface_name te1/0/22 console(config)#macro global apply profile-compellent-nas $interface_name te1/0/23 To configure a N4000 switch in a lossless DCBX environment where another switch connected to storage arrays supplies the DCBX configuration, perform the following steps starting with a default configuration: 1 Enter global configuration mode and configure the system MTU on the switch. console#configure console(config)#system jumbo mtu 9216 2 Create VLAN 100. This command also enters the VLAN configuration mode for VLAN 100. console(config)#vlan 100 console(config-vlan100)#exit 3 Enable VLAN tagging to allow the CNA ports 1-4 to carry 802.1p priority values through the network. console(config)#interface range te1/0/1-4 474 Configuring iSCSI Optimization console(config-if)#switchport mode trunk 4 Configure the DCBx port role as auto-downstream. This step automatically enables PFC and ETS on the ports using the configuration received from the other switch. console(config-if)#lldp dcbx port-role auto-down console(config-if)#exit 5 Enter interface configuration mode for the switch-facing ports and configure the DCBx port role as auto-up. This step automatically enables PFC and ETS on the ports using the configuration received from the other switch. console(config)#interface range te1/0/16-17 console(config-if)#lldp dcbx port-role auto-up 6 Add the ports to port-channel 1: console(config-if)#channel-group 1 mode active console(config-if)#exit 7 Configure the port-channel to be in trunk mode: console(config)#interface po1 console(config-if)#switchport mode trunk console(config-if)#exit To configure a N4000 switch in a lossless DCBX environment where the switch is directly connected to storage arrays and the CNAs (no other switch is present), perform the following steps starting from a default configuration: 1 Enter global configuration mode and configure the system MTU on the switch. console#configure console(config)#system jumbo mtu 9216 2 Create VLAN 100. This command also enters the VLAN configuration mode for VLAN 100. console(config)#vlan 100 console(config-vlan100)#exit 3 Enable iSCSI CoS. This enables generation of the iSCSI Application Priority TLV required by the CNAs. console(config)#iscsi cos enable 4 Map VLAN priority 4 onto traffic class 4. (config)#classofservice dot1p-mapping 4 4 Configuring iSCSI Optimization 475 5 Enter Interface Configuration mode for CNA connected ports 1-4 and array connected ports 16-17. console(config)#interface range te1/0/1-4,te1/0/16-17 6 Enable VLAN tagging to allow the CNA connected ports to carry 802.1p priority values through the network. console(config-if)#switchport mode trunk 7 Enter datacenter bridging mode to enable PFC on the ports. console(config-if)#datacenter-bridging 8 Enable PFC and configure traffic marked with 802.1p priority 4 to be paused rather than dropped when congestion occurs. console(config-if-dcb)#priority-flow-control mode on console(config-if-dcb)#priority-flow-control priority 4 no-drop console(config-if-dcb)#exit 9 Configure ETS by mapping the lossless traffic onto TC 1 and sharing bandwidth equally between the lossless and lossy traffic classes. console(config-if)#classofservice console(config-if)#classofservice console(config-if)#classofservice console(config-if)#classofservice console(config-if)#classofservice console(config-if)#classofservice traffic-class-group traffic-class-group traffic-class-group traffic-class-group traffic-class-group weight 50 50 0 10 Exit interface configuration mode for the range of interfaces. console(config-if)#exit 476 Configuring iSCSI Optimization 0 1 2 3 4 0 0 0 0 1 18 Configuring Port Characteristics This chapter describes how to configure physical switch port characteristics, including settings such as administrative status and maximum frame sizeGreen Ethernet settings. This chapter also describes the link dependency feature. The topics covered in this chapter include: • Port Overview • Default Port Values • Configuring Port Characteristics (Web) • Configuring Port Characteristics (CLI) • Port Configuration Examples Port Overview A port is a physical interface. Cables physically connect ports on devices such as PCs or servers to ports on the switch to provide access to the network. The number and type of physical ports available on your Dell Networking N2000, N3000, and N4000 series switches depends on the model. What Physical Port Characteristics Can Be Configured? Table 18-1Table 18-2 provides a summary of the physical characteristics that can be configured on the switch ports. Table 18-1. Port Characteristics Feature Description Administrative status Controls whether the port is administratively enabled or disabled. Description Provides a text-based description of the port. Configuring Port Characteristics 477 Table 18-1. Port Characteristics Feature Description Auto negotiation Enables a port to advertise its transmission rate, duplex mode and flow control abilities to its partner. Speed Specifies the transmission rate for frames. Duplex mode Specifies whether the interface supports transmission between the switch and the connected client in one direction at a time (half) or both directions simultaneously (both). Maximum frame size Indicates the maximum frame size that can be handled by the port. Green Ethernet features Green Ethernet features include: • Energy detect mode • Energy Efficient Ethernet (EEE), which enables the low-power idle mode Flow control This is a global setting that affects all ports. For more information about this feature, see "Configuring Port-Based Traffic Control" on page 787. Storm control For more information about this feature, see "Configuring Port-Based Traffic Control" on page 787. Port security For more information about this feature, see "Configuring Port and System Security" on page 503. Protected port For more information about this feature, see "Configuring Port-Based Traffic Control" on page 787. Table 18-2. Port Characteristics Feature Description Administrative status Controls whether the port is administratively enabled or disabled. Description Provides a text-based description of the port. 478 Configuring Port Characteristics Table 18-2. Port Characteristics (Continued) Feature Description Auto negotiation Enables a port to advertise its transmission rate, duplex mode and flow control abilities to its partner. Speed Specifies the transmission rate for frames. Duplex mode Specifies whether the interface supports transmission between the switch and the connected client in one direction at a time (half) or both directions simultaneously (both). Maximum frame size Indicates the maximum frame size that can be handled by the port. Flow control This is a global setting that affects all ports. For more information about this feature, see "Configuring Port-Based Traffic Control" on page 787. Storm control For more information about this feature, see "Configuring Port-Based Traffic Control" on page 787. Port security For more information about this feature, see "Configuring Port and System Security" on page 503. Protected port For more information about this feature, see "Configuring Port-Based Traffic Control" on page 787. What is Link Dependency? The link dependency feature provides the ability to enable or disable one or more ports based on the link state of one or more different ports. With link dependency enabled on a port, the link state of that port is dependent on the link state of another port. For example, if port A is dependent on port B and the switch detects a link loss on port B, the switch automatically brings down the link on port A. When the link is restored to port B, the switch automatically restores the link to port A. Configuring Port Characteristics 479 You can create a maximum of 72 dependency groups16 groups. The ports participating in the Link Dependency can be across all the Stack Units (Manager/Member unit). Link Action The link action specifies the action that the group members will take when the dependent port is down. The group members can transition to the same state as the dependant port, or they can transition to the opposite state. In other words, if the link action is down and the dependent port goes down, the members ports will go down as well. Conversely, when the link action is up and the dependant link goes down, the group member ports are enabled (brought up). Creating a link dependency group with the up link action essentially creates a backup link for the dependent link and alleviates the need to implement STP to handle the fail-over. Link Dependency Scenarios The Link Dependency feature supports the scenarios in the following list. NOTE: Whether the member ports or LAGs are brought up or down depends on the link action. 480 • Port dependent on port — If a port loses the link, the switch brings up/down the link on another port. • Port dependent on LAG — If all ports in a channel-group lose the link, the switch brings up/down the link on another port. • LAG dependent on port — If a port loses the link, the switch brings up/down all links in a channel-group. • Multiple port command — If a group of ports lose their link, the switch brings up/down the link on another group of ports. • Overlapping ports — Overlapping ports on different groups will be brought up/down only if both dependent ports lose the link. Configuring Port Characteristics What Interface Types are Supported? The physical ports on the switch include the out-of-band (OOB) interface (N3000 and N4000 only) and Ethernet switch ports. The OOB interface supports a limited set of features and is for switch management only. The Ethernet switch ports support many logical features that are often supported by logical interfaces. The switch supports the following types of logical interfaces: • Port-based VLANs — For more information, see "Configuring VLANs" on page 645. • VLAN routing interfaces — For more information, see "Configuring Routing Interfaces" on page 1021. • Link Aggregation Groups (LAGs), which are also called port-channels) — For more information, see "Configuring Link Aggregation" on page 913. • Tunnels — For more information, see "Configuring Routing Interfaces" on page 1021. • Loopback interfaces — For more information, see "Configuring Routing Interfaces" on page 1021. The Dell Networking switches includes the following Power over Ethernet (PoE) Plus models: the N2024P, N2048P, N3024P, N3048P. For information about configuring PoE plus features for the ports, see "Managing General System Settings" on page 279. N3000 and N4000 switches have a single expansion slot and can support the following module types: • 10GBaseT module • SFP+ module • QSFP+ module (N4000 only) What is Interface Configuration Mode? When you use the CLI to configure physical or logical characteristics for an interface, you must enter Interface Configuration Mode for that interface. To enter the mode, type the keyword interface followed by the interface type and additional information to identify the interface, such as the interface number. Configuring Port Characteristics 481 To enter Interface Configuration mode for a physical switch port, the following information is required: • Type — For physical switch ports, the type is Gigabit Ethernet (gigabitethernet or gi) for 10/100/1000 Mbps Ethernet ports or 10-Gibabit Ethernet (tengigabitethernet or te) for 10,000 Mbps Ethernet ports. • Stack member number— The unit number within the stack. The range is 1–12. The default unit number for a switch that has not been in a stack is 1. To view the member number assigned to each switch in a stack, use the show switch command. • Module (slot) number—For the N4000, the slot number is always 0.The expansion module slot. The number is 1 for a module inserted in the left slot or 2 when it is in the right slot (when viewing the back panel of the switch). For front-panel ports, the slot number is 0. • Port number—The number assigned to the port. For front-panel ports the port number is written above or below each port. Odd-numbered ports are on the top row, and even-numbered ports are on the bottom row. The port numbers increase from left to right. For ports on the optional modules, the left port is 1, and the right port is 2. For example, to enter Interface Configuration mode for Gigabit Ethernet port 10 on a switch that is not part of a stack, use the following command: console(config)#interface gigabitEthernet 1/0/10 For example, to enter Interface Configuration mode for 10-Gigabit Ethernet port 10, use the following command: console(config)#interface tengigabitEthernet 1/0/10 NOTE: When you enter Interface Configuration mode, the command prompt changes and identifies the interface. In the previous example, the command prompt becomes console(config-if-Te1/0/10)#. To enter Interface Configuration mode for Gigabit Ethernet port 6 on stack member 3, use the following command: console(config)#interface gigabitEthernet 3/0/6 To enter Interface Configuration mode for port 1 on a 10-Gigabit Ethernet module in the left slot, use the following command: console(config)#interface tengigabitEthernet 1/1/1 482 Configuring Port Characteristics For many features, you can configure a range of interfaces. When you enter Interface Configuration mode for multiple interfaces, the commands you execute apply to all interfaces specified in the range. To enter Interface Configuration mode for a range of interfaces, include the keyword range and specify the interfaces to configure. For example, to apply the same configuration to ports 1-10 on a standalone switch, use the following command: console(config)#interface range tengigabitEthernet 1/0/1-10 To enter Interface Configuration mode for ports 3, 4, 5, 12, and 14 on a standalone switch, use the following command: console(config)#interface range tengigabitEthernet 1/0/3-5,1/0/12,1/0/14 NOTE: You can switch to another interface or range of interfaces by entering the interface command while in Interface Configuration mode. It is not necessary to exit Interface Configuration mode to select a different interface. What Are the Green Ethernet Features? The Green Ethernet feature supports two per-port power-saving modes: • Energy-detect Mode • EEE All integrated 1G and module-based 10G copper ports on Dell Networking series switches are capable of utilizing the Energy Detect and EEE modes for reduced power consumption. When the Energy Detect mode is enabled and the port link is down, the PHY automatically goes down for short period of time and then wakes up to check link pulses. This mode reduces power consumption on the port when no link partner is present. EEE enables ports to enter a low-power mode to reduce power consumption during periods of low link utilization. EEE is defined by IEEE 802.3az. EEE enables both the send and receive sides of the link to disable some functionality for power savings when the link is lightly loaded. Configuring Port Characteristics 483 NOTE: Cable diagnostics may give misleading results if green mode is enabled on the port. Disable green mode prior to running any cable diagnostics. 484 Configuring Port Characteristics Default Port Values Table 18-3Table 18-4 lists the default values for the port characteristics that this chapter describes. Table 18-3. Default Port Values Feature Description Administrative status All ports are enabled Description None defined Auto negotiation Enabled Speed Auto-negotiate Duplex mode Auto-negotiate Flow control Enabled Maximum frame size 1518 Energy Detect mode Disabled EEE mode Disabled Link Dependency None configured Table 18-4. Default Port Values Feature Description Administrative status All ports are enabled Description None defined Auto negotiation Enabled Speed Auto negotiate Duplex mode Auto negotiate Flow control Enabled Maximum frame size 1518 Link Dependency None configured Configuring Port Characteristics 485 Configuring Port Characteristics (Web) This section provides information about the OpenManage Switch Administrator pages for configuring and monitoring port characteristics on a Dell Networking N2000, N3000, and N4000 series switches. For details about the fields on a page, click at the top of the page. Port Configuration Use the Port Configuration page to define port parameters. To display the Port Configuration page, click Switching → Ports → Port Configuration in the navigation panel. Figure 18-1. Port Configuration 486 Configuring Port Characteristics Configuring Multiple Ports To configure port settings on multiple ports: 1 Open the Port Configuration page. 2 Click Show All to display the Port Configuration Table page. 3 In the Ports list, select the check box in the Edit column for the port to configure. 4 Select the desired settings. 5 Click Apply. Figure 18-2. Configure Port Settings 6 Select the Copy Parameters From check box, and select the port with the settings to apply to other ports. 7 In the Ports list, select the check box(es) in the Copy To column that will have the same settings as the port selected in the Copy Parameters From field. In the following example, Ports 3, 4, and 5 will be updated with the settings that are applied to Port 1. Configuring Port Characteristics 487 Figure 18-3. Copy Port Settings 8 Click Apply. 488 Configuring Port Characteristics Link Dependency Configuration Use the Link Dependency Configuration page to create link dependency groups. You can create a maximum of 16 dependency groups. The page displays the groups whether they have been configured or not. To display the Link Dependency Configuration page, click Switching → Link Dependency → Configuration in the navigation panel. Figure 18-4. Link Dependency Configuration Creating a Link Dependency Group To create link dependencies: 1 Open the Link Dependency Configuration page. 2 In the Group ID field, select the ID of the group to configure. 3 Specify the link action. 4 To add a port to the Member Ports column, click the port in the Available Ports column, and then click the < button to the left of the Available Ports column. Ctrl + click to select multiple ports. 5 To add a port to the Ports Depended On column, click the port in the Available Ports column, and then click the > button to the right of the Available Ports column. Configuring Port Characteristics 489 In the following example, Group 1 is configured so that Port 3 is dependent on Port 4. Figure 18-5. Link Dependency Group Configuration 6 Click Apply. The Link Dependency settings for the group are modified, and the device is updated. 490 Configuring Port Characteristics Link Dependency Summary Use the Link Dependency Summary page to view all link dependencies on the system and to access the Link Dependency Configuration page. You can create a maximum of 16 dependency groups. The page displays the groups whether they have been configured or not. To display the Link Dependency Summary page, click Switching → Link Dependency → Link Dependency Summary in the navigation panel. Figure 18-6. Link Dependency Summary To configure a group, click the Modify link associated with the ID of the group to configure. Clicking the Modify link takes you to the Link Dependency Configuration page. The Group ID is automatically selected based on the link that was clicked. Configuring Port Characteristics 491 Port Green Ethernet Configuration Use the Green Ethernet Configuration page to enable or disable energysaving modes on each port. To display the Green Ethernet Configuration page, click System → Green Ethernet → Green Ethernet Configuration in the navigation panel. Figure 18-7. Green Ethernet Configuration 492 Configuring Port Characteristics Port Green Ethernet Statistics Use the Green Ethernet Statistics page to view information about per-port energy savings. To display the Green Ethernet Statistics page, click System → Green Ethernet → Green Ethernet Statistics in the navigation panel. Figure 18-8. Green Ethernet Statistics Configuring Port Characteristics 493 To view a summary of energy savings for the switch and all ports, click Summary. Figure 18-9. Green Ethernet Statistics Summary To view a chart that shows the estimated per-port energy savings, click Chart. Figure 18-10. 494 Green Ethernet Statistics Chart Configuring Port Characteristics Port Green Ethernet LPI History Use the Green Ethernet LPI History page to view data about the amount of time the switch has spent in low-power idle (LPI) mode. To display the Green Ethernet LPI History page, click System → Green Ethernet → Green Ethernet LPI History in the navigation panel. Figure 18-11. Green Ethernet LPI History Configuring Port Characteristics 495 Configuring Port Characteristics (CLI) This section provides information about the commands you use to configure port characteristics. For more information about the commands, see the Dell Networking N2000, N3000, and N4000 Series Switches CLI Reference Guide at support.dell.com/manuals. Configuring Port Settings Beginning in Privileged EXEC mode, use the following commands to configure various port settings. Command Purpose configure Enter Global Configuration mode. interface interface Enter interface configuration mode for the specified interface. The interface variable includes the interface type and number, for example tengigabitethernet 1/0/3. You can also specify a range of interfaces with the interface range command, for example, interface range tengigabitethernet 1/0/8-12 configures interfaces 8, 9, 10, 11, and 12. description string Add a description to the port. The text string can be from1-64 characters. shutdown Administratively disable the interface. 496 Configuring Port Characteristics Command Purpose speed {10 Configure the speed of a given Ethernet interface or allow |100|1000|10000 | auto the interface to automatically detect the speed. [100|1000|10000]} If you use the 100, 1000, or 10000 keywords with the auto keyword, the port auto-negotiates only at the specified speeds. Setting the speed without the auto keyword forces the speed to the selected value and disables autonegotiation. It is possible to configure a fiber port for a speed not supported by the transceiver. In this case, the port will not link up. On combo ports, it is possible to configure auto negotiation even if only the fiber interface is active. The auto negotiation settings will be utilized when the copper port is active. Auto negotiation settings are ignored for the fiber ports, as fiber ports alway operate in full-duplex fixed-speed mode. system jumbo mtu size Enable jumbo frames on the switch by adjusting the maximum size of a packet. CTRL + Z Exit to Privileged EXEC mode. show interfaces status Show summary information about all interfaces. show interfaces configuration View a summary of the configuration for all ports. show interfaces advertise View a summary of the speeds that are advertised on each port. show interfaces description View configured descriptions for all ports. show interfaces detail View detailed information about the specified port. interface Configuring Link Dependencies Beginning in Privileged EXEC mode, use the following commands to configure ports that are dependent on the state of other ports. Command Purpose configure Enter Global Configuration mode. Configuring Port Characteristics 497 Command Purpose link-dependency group group_id Enter the link-dependency mode to configure a linkdependency group. add interface Add member ports to the group. The interface variable includes the interface type and number, for example tengigabitethernet 1/0/3. You can also add port-channels (LAGs) as members by using the keyword port-channel followed by an ID. You can also specify a range of interfaces. For example, interface tengigabitethernet 1/0/8-10,1/0/20 configures interfaces 8, 9, 10 and 20. depends-on interface Specify the port(s) upon which the member ports are dependent. For information about the interface variable, see the previous command description. action {down|up} Specifies the action the member ports take when the dependent link goes down. • down—When the dependent link is down, the group members are down (the members are up otherwise). • up—When the dependent link goes down, the group members are brought up (the members are down otherwise) CTRL + Z Exit to Privileged EXEC mode. show link-dependency [group group_id] View link dependency settings for all groups or for the specified group, along with the group state. Configuring Green Features Beginning in Privileged EXEC mode, use the following commands to configure and monitor energy-saving features for the ports and the switch. Command Purpose configure Enter Global Configuration mode. 498 Configuring Port Characteristics Command Purpose interface interface Enter interface configuration mode for the specified interface. The interface variable includes the interface type and number, for example gigabitethernet 1/0/3. You can also specify a range of interfaces with the interface range command, for example, interface range gigabitethernet 1/0/8-12 configures interfaces 8, 9, 10, 11, and 12. green-mode energydetect Enable energy-detect mode on the interface. green-mode eee Enable EEE low power idle mode on the interface. exit Exit to global configuration mode. green-mode eee-lpihistory {samplinginterval seconds | maxsamples max} Configure the global EEE LPI history collection interval and buffer size. exit Exit to Privileged EXEC mode. show green-mode View green mode settings for the specified port. show green-mode eeelpi-history interface View the EEE LPI history statistics for the specified port. interface interface Configuring Port Characteristics 499 Port Configuration Examples This section contains the following examples: • Configuring Port Settings • Configuring a Link Dependency Groups Configuring Port Settings The commands in this example specify the speed and duplex mode for port 1 (gigabitEthernet 1/0/1) and change the system MTU size. To configure the switch: 1 Enter Interface Configuration mode for port 1. console#configure console(config)#interface gigabitEthernet 1/0/1 2 Change the speed and duplex settings for the port. console(config-if-Gi1/0/1)#speed 100 console(config-if-Gi1/0/1)#exit 3 Enable jumbo frame support on the interfaces. console(config)#system jumbo mtu 9216 console(config)#CTRL + Z 4 View summary information about the ports console#show interfaces configuration Port --------Gi1/0/1 Gi1/0/2 Gi1/0/3 Gi1/0/4 Gi1/0/5 Te1/0/1 Te1/0/2 Te1/0/3 Te1/0/4 Te1/0/5 Type ------------Gigabit - Level Gigabit - Level Gigabit - Level Gigabit - Level Gigabit - Level 10G - Level 10G - Level 10G - Level 10G - Level 10G - Level --More-- or (q)uit 500 Configuring Port Characteristics Duplex Speed Neg Admin St. ------ ------- ---- ----Full 100 Off Up N/A Unknown Auto Up N/A Unknown Auto Up N/A Unknown Auto Up N/A Unknown Auto Up N/A Unknown Auto Up N/A Unknown Auto Up N/A Unknown Auto Up N/A Unknown Auto Up N/A Unknown Auto Up Configuring a Link Dependency Groups The commands in this example create two link dependency groups. Group 1 has port 3 as a member port that is dependent on port 4. The group uses the default link action, which is down. This means that if port 4 goes down, port 3 goes down. When port 4 returns to the up state, port 3 is brought back up. In Group 2, port 6 dependent on port-channel (LAG) 1, and the link action is up. If port-channel 1 goes down, port 6 is brought up. This also means that when port-channel 1 is up, port 6 is down. To configure the switch: 1 Enter the configuration mode for Group 1. console#configure console(config)#link-dependency group 1 2 Configure the member and dependency information for the group. console(config-linkDep-group-1)#add tengigabitethernet 1/0/3 console(config-linkDep-group-1)#depends-on tengigabitethernet 1/0/4 console(config-linkDep-group-1)#exit 3 Enter the configuration mode for Group 2 console(config)#link-dependency group 2 console(config-linkDep-group-2)#add tengigabitethernet 1/0/6 console(config-linkDep-group-2)#depends-on portchannel 1 console(config-linkDep-group-2)#action up console(config-linkDep-group-2)#CTRL + Z 4 View the configured link dependency groups. console#show link-dependency GroupId ------1 2 Member Ports ------------Te1/0/3 te/0/6 Ports Depended On ----------------te/0/4 ch1 Link Action ---------Link Down Link Up Configuring Port Characteristics 501 502 Configuring Port Characteristics Configuring Port and System Security 19 This chapter describes how to configure port-based and system security features, which control access to the network through the switch ports, and the denial of service (DoS) feature. The topics covered in this chapter include: • Port-based Security—IEEE 802.1X and Port MAC Locking • Captive Portal • Authentication Manager • Denial of Service Port-based Security—IEEE 802.1X and Port MAC Locking Port-based security includes IEEE 802.1X authentication and port MAC locking. • IEEE 802.1X provides an authentication mechanism to devices connected to the switch. Network access is permitted only to authorized devices (clients). • Port MAC locking is used to enable security on a per-port basis. When a port is locked, only packets with allowable source MAC addresses can be forwarded. All other packets are discarded. Port-MAC locking allows a configurable limit to the number of source MAC addresses that can be learned on a port. NOTE: Port-based security can also be accomplished by using Access Control Lists (ACLs). For information about configuring ACLs, see "Configuring Access Control Lists" on page 583. Configuring Port and System Security 503 IEEE 802.1X What is IEEE 802.1X? The IEEE 802.1X standard provides a means of preventing unauthorized access by supplicants (clients) to the services the switch offers, such as access to the LAN. The 802.1X network has three components: • Supplicant — The client connected to the authenticated port that requests access to the network. • Authenticator — The network device that prevents network access prior to authentication. • Authentication Server — The network server (such as a RADIUS server) that performs the authentication on behalf of the authenticator, and indicates whether the user is authorized to access system services. Figure 19-1 shows the 802.1X network components. Figure 19-1. IEEE 802.1X Network Supplicant Authenticator Authentication Server LAN As shown in Figure 19-1, the Dell Networking N2000, N3000, and N4000 series switches is the authenticator and enforces the supplicant (a PC) that is attached to an 802.1X-controlled port to be authenticated by an 504 Configuring Port and System Security authentication server (a RADIUS server). The result of the authentication process determines whether the supplicant is authorized to access services on that controlled port. Dell Networking switches support authentication using remote RADIUS or TACACS servers and also support authentication using a local authentication service. Supported security methods for communication with remote servers include MD5, PEAP, EAP-TTL, EAP-TTLS, and EAP-TLS. Only EAP-MD5 is supported when using the local authentication server (IAS). For a list of RADIUS attributes that the switch supports, see "Using RADIUS Servers to Control Management Access" on page 232. What are the 802.1X Port States? The 802.1X port state determines whether to allow or prevent network traffic on the port. A port can configured to be in one of the following 802.1X control modes: • Auto (default) • MAC-based • Force-authorized • Force-unauthorized. These modes control the behavior of the port. The port state is either Authorized or Unauthorized. If the port is in the authorized state, the port sends and receives normal traffic without client port-based authentication. When a port is in an unauthorized state, it ignores supplicant authentication attempts and does not provide authentication services to the client. By default, when 802.1X is globally enabled on the switch, all ports are in Auto, which means the port will be unauthorized until a successful authentication exchange has taken place. In addition to authorized, unauthorized, and automode, the 802.1X mode of a port can be MAC based, as the following section describes. NOTE: Only MAC-Based and Automode actually use 802.1X to authenticate. Authorized and Unauthorized modes are manual overrides. Configuring Port and System Security 505 What is MAC-Based 802.1X Authentication? MAC-based authentication allows multiple supplicants connected to the same port to each authenticate individually. For example, a 5-port hub might be connected to a single port on the switch. Each host connected to the hub must authenticate separately in order to gain access to the network. The hosts are distinguished by their MAC addresses. NOTE: By default, all ports are in VLAN Access mode. A port that uses MACbased authentication should be configured to be in General mode. When multiple hosts (for example, a PC, a printer, and a phone in the same office) are connected to the switch on the same port, each of the connected hosts authenticates separately with the RADIUS server. If a port uses MAC-based 802.1X authentication, the option to use MAC Authentication Bypass (MAB) is available. MAB is a supplemental authentication mechanism that allows 802.1X unaware clients – such as printers, fax machines, and some IP phones — to authenticate to the network using the client MAC address as an identifier. The known and allowable MAC address and corresponding access rights of the client must be pre-populated in the authentication server. When a port configured for MAB receives traffic from an unauthenticated client, the switch (Authenticator): • Sends a EAP Request packet to the unauthenticated client • Waits a pre-determined period of time for a response • Retries – resends the EAP Request packet up to three times • Considers the client to be 802.1X unaware client (if it does not receive an EAP response packet from that client) The authenticator sends a request to the authentication server with the MAC address of the client in a hexadecimal format as the username and the MD5 hash of the MAC address as the password. The authentication server checks its database for the authorized MAC addresses and returns an Access-Accept or an Access-Reject response, depending on whether the MAC address is found in the database. MAB also allows 802.1X-unaware clients to be placed in a RADIUS-assigned VLAN or to apply a specific Filter ID to the client traffic. 506 Configuring Port and System Security NOTE: MAB initiates only after the dot1x guest VLAN period times out. If the client responds to any of the EAPOL identity requests, MAB does not initiate for that client. What is the Role of 802.1X in VLAN Assignment? Dell Networking series switches allow a port to be placed into a particular VLAN based on the result of the authentication or type of 802.1X authentication a client uses when it accesses the switch. The authentication server can provide information to the switch about which VLAN to assign the supplicant. When a host connects to a switch that uses an authentication server to authenticate, the host authentication can typically have one of three outcomes: • The host is authenticated. • The host attempts to authenticate but fails because it lacks certain security credentials. • The host is a guest and does not try to authenticate at all (802.1X unaware). You can create three separate VLANs on the switch to handle a host depending on whether the host authenticates, fails the authentication, or is a guest. The RADIUS server informs the switch of the selected VLAN as part of the authentication. Authenticated and Unauthenticated VLANs Hosts that authenticate normally use a VLAN that includes access to network resources. Hosts that fail the authentication might be denied access to the network or placed on a quarantine VLAN with limited network access. Much of the configuration to assign authenticated hosts to a particular VLAN takes place on the 802.1X authenticator server (for example, a RADIUS server). If you use an external RADIUS server to manage VLANs, you configure the server to use Tunnel attributes in Access-Accept messages in order to inform the switch about the selected VLAN. These attributes are defined in RFC 2868, and their use for dynamic VLAN is specified in RFC 3580. The VLAN attributes defined in RFC3580 are as follows: • Tunnel-Type=VLAN (13) Configuring Port and System Security 507 • Tunnel-Medium-Type=802 • Tunnel-Private-Group-ID=VLANID VLANID is 12-bits and has a value between 1 and 4093. Dynamic VLAN Creation If RADIUS-assigned VLANs are enabled though the Authorization Network RADIUS configuration option, the RADIUS server is expected to include the VLAN ID in the 802.1X tunnel attributes of its response message to the switch. If dynamic VLAN creation is enabled on the switch and the RADIUSassigned VLAN does not exist, then the assigned VLAN is dynamically created. This implies that the client can connect from any port and can get assigned to the appropriate VLAN. This gives flexibility for clients to move around the network without much additional configuration required. Guest VLAN The Guest VLAN feature allows a switch to provide a distinguished service to unauthenticated users. This feature provides a mechanism to allow users access to hosts on the guest VLAN. For example, a company might provide a guest VLAN to visitors and contractors to permit network access that allows visitors to connect to external network resources, such as the Internet, with no ability to browse information on the internal LAN. In port-based 802.1X mode, when a client that does not support 802.1X is connected to an unauthorized port that is 802.1X-enabled, the client does not respond to the 802.1X requests from the switch. Therefore, the port remains in the unauthorized state, and the client is not granted access to the network. If a guest VLAN is configured for that port, then the port is placed in the configured guest VLAN and the port is moved to the authorized state, allowing access to the client. However, if the port is in MAC-based 802.1X authentication mode, it will not move to the authorized state. MAC-based mode makes it possible for both authenticated and guest clients to use the same port at the same time. NOTE: MAB and the guest VLAN feature are mutually exclusive on a port. Client devices that are 802.1X-supplicant-enabled authenticate with the switch when they are plugged into the 802.1X-enabled switch port. The switch verifies the credentials of the client by communicating with an 508 Configuring Port and System Security authentication server. If the credentials are verified, the authentication server informs the switch to unblock the switch port and allows the client unrestricted access to the network; i.e., the client is a member of an internal VLAN. Guest VLAN mode can be configured on a per-port basis. If a client does not attempt authentication on a port, and the port is configured for the guest VLAN, the client is assigned to the guest VLAN configured on that port. The port is assigned a guest VLAN ID and is moved to the authorized status. When the guest VLAN is disabled, users authorized by the guest VLAN are removed. What is Monitor Mode? The monitor mode is a special mode that can be enabled in conjunction with 802.1X authentication. Monitor mode provides a way for network administrators to identify possible issues with the 802.1X configuration on the switch without affecting the network access to the users of the switch. It allows network access even in case where there is a failure to authenticate but logs the results of the authentication process for diagnostic purposes. The monitor mode can be configured globally on a switch. If the switch fails to authenticate a user for any reason (for example, RADIUS access reject from RADIUS server, RADIUS timeout, or the client itself is dot1x-unaware), the client is authenticated and is undisturbed by the failure condition(s). The reasons for failure are logged for tracking purposes. Table 19-1 provides a summary of the 802.1X Monitor Mode behavior. Table 19-1. IEEE 802.1X Monitor Mode Behavior Case Sub-case Regular Dot1x Dot1x Monitor Mode RADIUS/IAS Success Success Port State: Permit VLAN: Assigned Filter: Assigned Port State: Permit VLAN: Assigned Filter: Assigned Incorrect NAS Port Port State: Deny Port State: Permit VLAN: Default PVID of the port Invalid VLAN Assignment Port State: Deny Port State: Permit VLAN: Default PVID of the port Configuring Port and System Security 509 Table 19-1. IEEE 802.1X Monitor Mode Behavior (Continued) Case Sub-case Regular Dot1x Dot1x Monitor Mode Invalid Filter-id Port State: Deny Port State: Permit VLAN: Default PVID of the port Bad RADIUS packet Port State: Deny Port State: Permit VLAN: Default PVID of the port Default behavior Port State: Deny Port State: Permit VLAN: Default PVID of the port Unauth VLAN enabled Port State: Permit VLAN: Unauth Port State: Permit VLAN: Unauth Default behavior Port State: Deny Port State: Permit VLAN: Default PVID of the port Unauth VLAN enabled Port State: Deny Port State: Permit VLAN: Unauth EAPOL Timeout Default behavior Port State: Deny Port State: Permit 3 × EAPOL Timeout Guest VLAN enabled Port State: Permit VLAN: Guest Port State: Permit VLAN: Guest MAB Success Case Port State: Permit VLAN: Assigned Filter: Assigned Port State: Permit VLAN: Assigned Filter: Assigned MAB Fail Case Port State: Deny Port State: Permit VLAN: Default PVID of the port Port State: Deny Port State: Deny RADIUS/IAS Failure RADIUS Timeout (Guest VLAN timer expiry or MAB timer expiry) Supplicant Timeout 510 Configuring Port and System Security Table 19-1. IEEE 802.1X Monitor Mode Behavior (Continued) Case Sub-case Port/Client Delete Guest Authenticated VLANID through on Guest VLAN Dot1Q Regular Dot1x Dot1x Monitor Mode Port State: Deny Port State: Permit VLAN: Default PVID of the port How Does the Authentication Server Assign DiffServ Filters? The Dell Networking series switches allow the external 802.1X Authenticator or RADIUS server to assign DiffServ policies to users that authenticate to the switch. When a host (supplicant) attempts to connect to the network through a port, the switch contacts the 802.1X authenticator or RADIUS server, which then provides information to the switch about which DiffServ policy to assign the host (supplicant). The application of the policy is applied to the host after the authentication process has completed. For additional guidelines about using an authentication server to assign DiffServ policies, see "Configuring Authentication Server DiffServ Filter Assignments" on page 535. What is the Internal Authentication Server? The Internal Authentication Server (IAS) is a dedicated database for localized authentication of users for network access through 802.1X. In this database, the switch maintains a list of username and password combinations to use for 802.1X authentication. You can manually create entries in the database, or you can upload the IAS information to the switch. If the authentication method for 802.1X is IAS, the switch uses the locally stored list of username and passwords to provide port-based authentication to users instead of using an external authentication server. Authentication using the IAS supports the EAP-MD5 method only. NOTE: The IAS database does not handle VLAN assignments or DiffServ policy assignments. Default 802.1X Values Table 19-2 lists the default values for the 802.1X features. Configuring Port and System Security 511 Table 19-2. Default Port-Based Security Values Feature Description Global 802.1X status Disabled 802.1X authentication method none Per-port 802.1X status Disabled Port state automode Periodic reauthentication Disabled Seconds between reauthentication attempts 3600 Authentication server timeout 30 seconds Resending EAP identity Request 30 seconds Quiet period 60 seconds Supplicant timeout 30 seconds Max EAP request 2 times Maximum number of supplicants per port 16 for MAC-based authentication mode Guest VLAN Disabled Unauthenticated VLAN Disabled Dynamic VLAN creation Disabled RADIUS-assigned VLANs Disabled IAS users none configured Port security Unlocked Port security traps Disabled Maximum learned MAC addresses 100 (when locked) Monitor mode Disabled Configuring IEEE 802.1X (Web) This section provides information about the OpenManage Switch Administrator pages for configuring and monitoring the IEEE 802.1X features and Port Security on a Dell Networking N2000, N3000, and N4000 512 Configuring Port and System Security series switches. For details about the fields on a page, click the page. at the top of Dot1x Authentication Use the Dot1x Authentication page to configure the 802.1X administrative mode on the switch and to configure general 802.1X parameters for a port. To display the Dot1x Authentication page, click Switching → Network Security → Dot1x Authentication → Authentication in the navigation panel. Figure 19-2. Dot1x Authentication To configure 802.1X authentication on multiple ports: 1 Open the Dot1x Authentication page. Configuring Port and System Security 513 2 Click Show All to display the Dot1x Authentication Table page. 3 In the Ports list, select the check box in the Edit column for the port to configure. 4 Select the desired settings to change for all ports that are selected for editing. Figure 19-3. Configure Dot1x Settings 5 Click Apply. To reauthenticate a port: 1 Open the Dot1x Authentication page. 2 Click Show All. The Dot1x Authentication Table displays. 3 Check Edit to select the Unit/Port to re-authenticate. 4 Check Reauthenticate Now. 5 Click Apply. The authentication process is restarted on the specified port. To reauthenticate multiple ports: 1 Open the Dot1x Authentication page. 2 Click Show All. The Dot1x Authentication Table displays. 3 Check Edit to select the Units/Ports to re-authenticate. 4 To re-authenticate on a periodic basis, set Periodic Re-Authentication to Enable, and specify a Re-Authentication Period for all desired ports. 514 Configuring Port and System Security 5 To re-authenticate immediately, check Reauthenticate Now for all ports to be re-authenticated. 6 Click Apply. The authentication process is restarted on the specified ports (either immediately or periodically). To change the administrative port control: 1 Open the Dot1x Authentication page. 2 Click Show All. The Dot1x Authentication Table displays. 3 Scroll to the right side of the table and select the Edit check box for each port to configure. Change Admin Port Control to Authorized, Unauthorized, or Automode as needed for chosen ports. Only MACBased and Automode actually use 802.1X to authenticate. Authorized and Unauthorized are manual overrides. 4 Click Apply. Admin Port Control is updated for the specified ports, and the device is updated. Authenticated Users The Authenticated Users page is used to display lists of ports that have authenticated users. To display the Authenticated Users page, click Switching → Network Security → Authenticated Users in the navigation panel. Configuring Port and System Security 515 Figure 19-4. Network Security Authenticated Users Port Access Control Configuration Use the Port Access Control Configuration page to globally enable or disable RADIUS-assigned VLANs and to enable Monitor Mode to help troubleshoot 802.1X configuration issues. NOTE: The VLAN Assignment Mode field is the same as the Admin Mode field on the System → Management Security → Authorization Network RADIUS page. To display the Port Access Control Configuration page, click Switching → Network Security → Dot1x Authentication → Monitor Mode → Port Access Control Configuration in the navigation panel. Figure 19-5. Port Access Control Configuration 516 Configuring Port and System Security Port Access Control History Log Summary Use the Port Access Control History Log Summary page to view log messages about 802.1X client authentication attempts. The information on this page can help you troubleshoot 802.1X configuration issues. To display the Port Access Control History Log Summary page, click Port Access Control Configuration page, click Switching → Network Security → Dot1x Authentication → Monitor Mode → Port Access Control History Log Summary in the navigation panel. Figure 19-6. Port Access Control History Log Summary Internal Authentication Server Users Configuration Use the Internal Authentication Server Users Configuration page to add users to the local IAS database and to view the database entries. To display the Internal Authentication Server Users Configuration page, click System → Management Security → Internal Authentication Server Users Configuration in the navigation panel. Configuring Port and System Security 517 Figure 19-7. Internal Authentication Server Users Configuration NOTE: If no users exist in the IAS database, the IAS Users Configuration Page does not display the fields shown in the image. To add IAS users: 1 Open the Internal Authentication Server Users Configuration page. 2 Click Add to display the Internal Authentication Server Users Add page. 3 Specify a username and password in the appropriate fields. Figure 19-8. Adding an IAS User 4 Click Apply. To view the Internal Authentication Server Users Table page, click Show All. To delete an IAS user: 1 Open the Internal Authentication Server Users Configuration page. 518 Configuring Port and System Security 2 From the User menu, select the user to remove, select the user to remove. 3 Select the Remove check box. Figure 19-9. Removing an IAS User 4 Click Apply. Configuring Port and System Security 519 Configuring IEEE 802.1X (CLI) This section provides information about commands you use to configure 802.1X and Port Security settings. For additional information about the commands in this section, see the Dell Networking N2000, N3000, and N4000 Series Switches CLI Reference Guide at support.dell.com/manuals. Configuring Basic 802.1X Authentication Settings Beginning in Privileged EXEC mode, use the following commands to enable and configure 802.1X authentication on the switch. Command Purpose configure Enter Global Configuration mode. aaa accounting dot1x default Sets 802.1X accounting to the default operational mode aaa authentication dot1x default method1 Specify the authentication method to use to authenticate 802.1X clients that connect to the switch. method1—The method keyword can be radius, none, or ias. dot1x system-authcontrol Globally enable 802.1X authentication on the switch. interface interface Enter interface configuration mode for the specified interface. The interface variable includes the interface type and number, for example tengigabitethernet 1/0/3. You can also specify a range of interfaces with the interface range command, for example, interface range tengigabitethernet 1/0/8-12 configures interfaces 8, 9, 10, 11, and 12. 520 Configuring Port and System Security Command Purpose dot1x port-control {force-authorized | force-unauthorized | auto | mac-based} Specify the 802.1X mode for the port. NOTE: For standard 802.1X implementations in which one client is connected to one port, use the dot1x port-control auto command to enable 802.1X authentication on the port. • auto — Enables 802.1X authentication on the interface and causes the port to transition to the authorized or unauthorized state based on the 802.1X authentication exchange between the switch and the client. • force-authorized — Disables 802.1X authentication on the interface and causes the port to transition to the authorized state without any authentication exchange required. The port sends and receives normal traffic without 802.1X-based authentication of the client. • force-unauthorized — Denies all access through this interface by forcing the port to transition to the unauthorized state, ignoring all attempts by the client to authenticate. The switch cannot provide authentication services to the client through the interface. • mac-based — Enables 802.1X authentication on the interface and allows multiple hosts to authenticate on a single port. The hosts are distinguished by their MAC addresses. dot1x mac-auth-bypass If the 802.1X mode on the interface is mac-based, you can optionally use this command to enable MAB on an interface. CTRL + Z Exit to Privileged EXEC mode. show dot1x View the current 802.1X configuration. show dot1x clients {all | View information about 802.1X clients that have successfully authenticated and are connected to the switch. The interface variable includes the interface type and number. interface} show dot1x users [username username] View the 802.1X authenticated users for the switch. Configuring Port and System Security 521 NOTE: To enable 802.1X Monitor Mode to help troubleshoot authentication issues, use the dot1x system-auth-control monitor command in Global Configuration mode. To view 802.1X authentication events and information, use the show dot1x authentication-history { | all} [failed-auth-only] [detail] command in Privileged EXEC mode. To clear the history, use the clear dot1x authenticationhistory command. Configuring Additional 802.1X Interface Settings Beginning in Privileged EXEC mode, use the following commands to configure 802.1X interface settings such as the reauthentication period and switch-to-client retransmission time. Command Purpose configure Enter Global Configuration mode. interface interface Enter interface configuration mode for the specified interface. The interface variable includes the interface type and number, for example tengigabitethernet 1/0/3. You can also specify a range of interfaces with the interface range command, for example, interface range tengigabitethernet 1/0/8-12 configures interfaces 8, 9, 10, 11, and 12. dot1x reauthentication Enable periodic re-authentication of the client. dot1x timeout reauthperiod seconds Set the number of seconds between re-authentication attempts. dot1x timeout servertimeout seconds Set the time that the switch waits for a response from the authentication server. dot1x timeout tx-period Set the number of seconds that the switch waits for a response to an Extensible Authentication Protocol (EAP)request/identity frame from the client before resending the request. seconds dot1x timeout quietperiod seconds 522 Set the number of seconds that the switch remains in the quiet state following a failed authentication exchange (for example, the client provided an invalid password). Configuring Port and System Security Command Purpose dot1x timeout supptimeout seconds Set the time that the switch waits for a response before retransmitting an Extensible Authentication Protocol (EAP)-request frame to the client. dot1x max-req count Set the maximum number of times that the switch sends an Extensible Authentication Protocol (EAP)-request frame (assuming that no response is received) to the client before restarting the authentication process. dot1x max-users users Set the maximum number of clients supported on the port when MAC-based 802.1X authentication is enabled on the port. CTRL + Z Exit to Privileged EXEC mode. dot1x re-authenticate [interface] Manually initiate the re-authentication of all 802.1Xenabled ports or on the specified 802.1X-enabled port. The interface variable includes the interface type and number. dot1x initialize [interface] Start the initialization sequence on all ports or on the specified port. NOTE: This command is valid only if the port-control mode for the specified port is auto or MAC-based. interface] show dot1x [interface View 802.1X settings for the switch or for the specified interface. show dot1x interface View 802.1X statistics for the specified interface. interface statistics Configuring 802.1X Settings for RADIUS-Assigned VLANs Beginning in Privileged EXEC mode, use the following commands to configure 802.1X settings that affect the RADIUS-assigned VLAN. Command Purpose configure Enter Global Configuration mode. aaa authorization network default radius Allow the RADIUS server to assign VLAN IDs to clients. Configuring Port and System Security 523 Command Purpose dot1x dynamic-vlan enable If the RADIUS assigned VLAN does not exist on the switch, allow the switch to dynamically create the assigned VLAN. interface interface Enter interface configuration mode for the specified interface. The interface variable includes the interface type and number, for example tengigabitethernet 1/0/3. You can also specify a range of interfaces with the interface range command, for example, interface range tengigabitethernet 1/0/8-12 configures interfaces 8, 9, 10, 11, and 12. dot1x guest-vlan vlan-id Specify the guest VLAN. dot1x unauth-vlan vlan- Specify the unauthenticated VLAN. The VLAN must already have been created. id CTRL + Z Exit to Privileged EXEC mode. show dot1x advanced View the current 802.1X configuration. interface NOTE: When dynamically creating VLANs, the uplink port should be in trunk mode so that it will automatically participate in all dynamically-created VLANs. Otherwise, the supplicant may be placed in a VLAN that does not go beyond the switch because no other ports are participating. 524 Configuring Port and System Security Configuring Internal Authentication Server Users Beginning in Privileged EXEC mode, use the following commands to add users to the IAS database and to use the database for 802.1X authentication. Command Purpose configure Enter Global Configuration mode. aaa ias-user username Add a user to the IAS user database. This command also changes the mode to the AAA User Config mode. password password [encrypted] Configure the password associated with the user. CTRL + Z Exit to Privileged EXEC mode. show aaa ias-users View all configured IAS users. clear aaa ias-users Delete all IAS users from the database. user IEEE 802.1X Configuration Examples This section contains the following examples: • Configuring 802.1X Authentication • Controlling Authentication-Based VLAN Assignment • Allowing Dynamic VLAN Creation of RADIUS-Assigned VLANs • Configuring Authentication Server DiffServ Filter Assignments Configuring 802.1X Authentication The network in this example requires clients to use 802.1X authentication to access the network through the switch ports. The administrator must configure the following settings on systems other than the switch before configuring the switch: 1 Add the users to the client database on the Authentication Server, such as a RADIUS server with Cisco® Secure Access Control Server (ACS) software. 2 Configure the settings on the client, such a PC running Microsoft® Windows, to require 802.1X authentication. Configuring Port and System Security 525 The switch uses an authentication server with an IP address of 10.10.10.10 to authenticate clients. Port 7 is connected to a printer in the unsecured area. The printer is an 802.1X unaware client, so Port 7 is configured to use MACbased authentication with MAB. NOTE: The printer requires an entry in the client database that uses the printer MAC address as the username. An IP phone is directly connected to Port 8, and a PC is connected to the IP phone. Both devices are authenticated through MAC-based authentication, which allows multiple hosts to authenticate on a single port. The hosts are distinguished by their MAC addresses, and hosts authenticate separately with the RADIUS server. Port 9 is connected to a server in a part of the network that has secure physical access (i.e. the doors to the wiring closet and data center are locked), so this port is set to the Authorized state, meaning that the device connected to this port does not need to authenticate using 802.1X. Port 24 is the uplink to a router and is also in the Authorized state. 526 Configuring Port and System Security Figure 19-10. 802.1X Example Physically Unsecured Devices Clients (Ports 1 and 3) Physically Secured Devices Authentication Server (RADIUS) Dell Networking Switch Clients (Port 8) Printer (Port 7) LAN Uplink (Port 24) LAN Server (Port 9) The following example shows how to configure the example shown in Figure 19-10. 1 Configure the RADIUS server IP address and shared secret (secret). console#configure console(config)#radius-server host 10.10.10.10 console(Config-radius)#exit console(config)#radius-server key secret console(config)#exit 2 Enable 802.1X port-based access control on the switch. console(config)#dot1x system-auth-control 3 Configure ports 9 and 24 to be in the Authorized state, which allows the devices to connect to these ports to access the switch services without authentication. console(config)#interface range Gi1/0/9,Gi1/0/24 Configuring Port and System Security 527 console(config-if)#dot1x port-control forceauthorized console(config-if)#exit 4 Configure Port 7 to require MAC-based authentication with MAB. console(config)#interface gi1/0/7 console(config-if-Gi1/0/7)#dot1x port-control macbased console(config-if-Gi1/0/7)#dot1x mac-auth-bypass 5 Set the port to an 802.1Q VLAN. The port must be in general mode in order to enable MAC-based 802.1X authentication. console(config-if-Gi1/0/7)#switchport mode general console(config-if-Gi1/0/7)#exit 6 Enable MAC-based authentication on port 8 and limit the number of devices that can authenticate on that port to 2. console(config)#interface gi1/0/8 console(config-if-Gi1/0/8)#dot1x port-control macbased console(config-if-Gi1/0/8)#dot1x max-users 2 7 Set Port 8 to switchport mode general. The port must be in general mode in order to enable MAC-based 802.1X authentication. console(config-if-Gi1/0/8)#switchport mode general console(config-if-Gi1/0/8)#exit console(config)#exit 8 View the client connection status. When the clients on Ports 1, 3, and 7(supplicants), attempt to communicate via the switch, the switch challenges the supplicants for 802.1X credentials. The switch encrypts the provided information and transmits it to the RADIUS server. If the RADIUS server grants access, the system sets the 802.1X port state of the interface to authorized and the supplicants are able to access network resources. console#show dot1x clients all Interface...................................... User Name...................................... Supp MAC Address............................... Session Time................................... 528 Configuring Port and System Security Gi1/0/1 aoversmit 0012.1753.031A 756 Filter Id...................................... VLAN Assigned.................................. 1 (Default) Interface...................................... User Name...................................... Supp MAC Address............................... Session Time................................... Filter Id...................................... VLAN Assigned.................................. Gi1/0/3 dflint 0004.5A55.EFAD 826 Interface...................................... User Name...................................... Supp MAC Address............................... Session Time................................... Filter Id...................................... VLAN Assigned.................................. Gi1/0/7 0006.6B33.06BA 0006.6B33.06BA 826 1 (Default) 1 (Default) 9 View a summary of the port status. console#show dot1x Administrative Mode............... Enabled Port Admin Oper Mode Mode ------- ---------------- -----------Gi1/0/1 auto Authorized Gi1/0/2 auto N/A Gi1/0/3 auto Authorized Gi1/0/4 auto N/A Gi1/0/5 auto N/A Gi1/0/6 auto N/A Gi1/0/7 mac-based Authorized Gi1/0/8 mac-based N/A Gi1/0/9 force-authorized Authorized Gi1/0/10 force-authorized Authorized Gi1/0/11 auto N/A --More-- or (q)uit Reauth Reauth Control Period -------- ---------FALSE 3600 FALSE 3600 FALSE 3600 FALSE 3600 FALSE 3600 FALSE 3600 FALSE 3600 FALSE 3600 FALSE 3600 FALSE 3600 FALSE 3600 Configuring Port and System Security 529 10 View 802.1X information about Port 8. console#show dot1x interface Gi1/0/8 Administrative Mode............... Enabled Dynamic VLAN Creation Mode........ Enabled Monitor Mode...................... Disabled Port ------Gi1/0/8 Admin Oper Reauth Reauth Mode Mode Control Period ---------------- ------------ -------- ---------mac-based Authorized FALSE 3600 Quiet Period................................... Transmit Period................................ Maximum Requests............................... Max Users...................................... VLAN Assigned.................................. Supplicant Timeout............................. Guest-vlan Timeout............................. Server Timeout (secs).......................... MAB mode (configured).......................... MAB mode (operational)......................... 60 30 2 2 1 (Default) 30 90 30 Disabled Disabled Controlling Authentication-Based VLAN Assignment The network in this example uses three VLANs to control access to network resources. When a client connects to the network, it is assigned to a particular VLAN based on one of the following events: • It attempts to contact the 802.1X server and is authenticated. • It attempts to contact the 802.1X server and fails to authenticate. • It does not attempt to contact the 802.1X server. The following table describes the three VLANs: VLAN ID VLAN Name VLAN Purpose 100 Authorized Data from authorized clients 200 Unauthorized Data traffic from clients that fail the authentication with the RADIUS server 300 Guest Data traffic from clients that do not attempt to authenticate with the RADIUS server 530 Configuring Port and System Security NOTE: Dynamic VLAN creation applies only to authorized ports. The VLANs for unauthorized and guest users must be configured on the switch and cannot be dynamically created based on RADIUS-based VLAN assignment. The commands in this example show how to configure the switch to control VLAN assignment for the example network. This example also contains commands to configure the uplink, or trunk, port (a port connected to a router or the internal network), and to configure the downlink, or access, ports (ports connected to one or more hosts). Ports 1–23 are downstream ports. Port 24 is an uplink port. An external RADIUS server handles the VLAN assignment. NOTE: The configuration to control the VLAN assignment for authorized users is done on the external RADIUS server. Configuring Port and System Security 531 To configure the switch: 1 Create the VLANs and configure the VLAN names. console(config)#vlan 100 console(config-vlan100)#name Authorized console(config-vlan100)#exit console(config)#vlan 200 console(config-vlan200)#name Unauthorized console(config-vlan200)#exit console(config)#vlan 300 console(config-vlan300)#name Guest console(config-vlan300)#exit 2 Configure information about the external RADIUS server the switch uses to authenticate clients. The RADIUS server IP address is 10.10.10.10, and the shared secret is qwerty123. console(config)#radius-server key qwerty123 console(config)#radius-server host 10.10.10.10 console(Config-auth-radius)#exit 3 Enable 802.1X on the switch. console(config)#dot1x system-auth-control 4 Create a default authentication login list and use the RADIUS server for port-based authentication for connected clients. console(config)#aaa authentication dot1x default radius 5 Allow the switch to accept VLAN assignments by the RADIUS server. console(config)#aaa authorization network default radius 6 Enter interface configuration mode for the downlink ports. console(config)#interface range Gi1/0/1-23 7 Set the downlink ports to the access mode because each downlink port connects to a single host that belongs to a single VLAN. console(config-if)#switchport mode access 532 Configuring Port and System Security 8 Enable periodic reauthentication of the client on the ports and set the number of seconds to wait between reauthentication attempts to 300 seconds. Reauthentication is enabled to increase security. If the client information is removed from the RADIUS server after it has been authenticated, the client will be denied access when it attempts to reauthenticate. console(config-if)#dot1x reauthentication console(config-if)#dot1x timeout re-authperiod 300 9 Set the unauthenticated VLAN on the ports to VLAN 200 so that any client that connects to one of the ports and fails the 802.1X authentication is placed in VLAN 200. console(config-if)#dot1x unauth-vlan 200 10 Set the guest VLAN on the ports to VLAN 300. This command automatically enables the Guest VLAN Mode on the downlink ports. Any client that connects to the port and does not attempt to authenticate is placed on the guest VLAN. console(config-if)#dot1x guest-vlan 300 console(config-if)#exit 11 Enter Interface Configuration mode for port 24, the uplink (trunk) port. console(config)#interface Gi1/0/24 12 Disable 802.1X authentication on the interface. This causes the port to transition to the authorized state without any authentication exchange required. This port does not connect to any end-users, so there is no need for 802.1X-based authentication. console(config-if-Gi1/0/24)#dot1x port-control force-authorized 13 Set the uplink port to trunk mode so that it accepts tagged traffic and transmits it to the connected device (another switch or router). console(config-if-Gi1/0/24)#switchport mode trunk Configuring Port and System Security 533 Allowing Dynamic VLAN Creation of RADIUS-Assigned VLANs The network in this example uses a RADIUS server to provide VLAN assignments to host that connect to the switch. In this example, the VLANs are not configured on the switch. Instead, the switch is configured to allow the dynamic creation of VLANs when a RADIUS-assigned VLAN does not already exist on the switch. In this example, Ports 1–23 are configured as downlink, or access, ports, and Port 24 is the trunk port. As a trunk port, Port 24 is automatically added as a member to all VLANs that are statically or dynamically configured on the switch. However, the network administrator in this example has determined that traffic in VLANs 1000–2000 should not be forwarded on the trunk port, even if the RADIUS server assigns a connected host to a VLAN in this range, and the switch dynamically creates the VLAN. NOTE: The configuration to control the VLAN assignment for hosts is done on the external RADIUS server. To configure the switch: 1 Configure information about the external RADIUS server the switch uses to authenticate clients. The RADIUS server IP address is 10.10.10.10, and the shared secret is qwerty123. console(config)#radius-server key qwerty123 console(config)#radius-server host 10.10.10.10 console(Config-auth-radius)#exit 2 Enable 802.1X on the switch. console(config)#dot1x system-auth-control 3 Create a default authentication login list and use the RADIUS server for port-based authentication for connected clients. console(config)#aaa authentication dot1x default radius 4 Allow the switch to accept VLAN assignments by the RADIUS server. console(config)#aaa authorization network default radius 534 Configuring Port and System Security 5 Allow the switch to dynamically create VLANs when a RADIUS-assigned VLAN does not exist on the switch. console(config)#dot1x dynamic-vlan enable 6 Enter interface configuration mode for the downlink ports. console(config)#interface range Gi1/0/1-23 7 Set the downlink ports to the access mode because each downlink port connects to a single host that belongs to a single VLAN. console(config-if)#switchport mode access console(config-if)#exit 8 Enter Interface Configuration mode for port 24, the uplink (trunk) port. console(config)#interface Gi1/0/24 9 Disable 802.1X authentication on the interface. This causes the port to transition to the authorized state without any authentication exchange required. This port does not connect to any end-users, so there is no need for 802.1X-based authentication. console(config-if-Gi1/0/24)#dot1x port-control force-authorized 10 Set the uplink port to trunk mode so that it accepts tagged traffic and transmits it to the connected device (another switch or router). console(config-if-Gi1/0/24)#switchport mode trunk 11 Forbid the trunk from forwarding traffic that has VLAN tags for any VLAN from 1000–2000, inclusive. console(config-if-Gi1/0/24)#switchport trunk allowed vlan remove 1000-2000 console(config-if-Gi1/0/24)#exit Configuring Authentication Server DiffServ Filter Assignments To enable DiffServ filter assignment by an external server, the following conditions must be true: • The port that the host is connected to must be enabled for MAC-based port access control by using the following command in Interface Config mode: dot1x port-control mac-based Configuring Port and System Security 535 • The RADIUS or 802.1X server must specify the policy to assign. For example, if the DiffServ policy to assign is named internet_access, include the following attribute in the RADIUS or 802.1X server configuration: Filter-id = “internet_access” • The DiffServ policy specified in the attribute must already be configured on the switch, and the policy names must be identical. For information about configuring a DiffServ policy, see "DiffServ Configuration Examples" on page 1307. The example "Providing Subnets Equal Access to External Network" on page 1307, describes how to configure a policy named internet_access. If you use an authentication server to assign DiffServ policies to an authenticated user, note the following guidelines: • If the policy specified within the server attribute does not exist on the switch, authentication will fail. • Do not delete policies used as the filter ID in the RADIUS server while 802.1X is enabled. • Do not use the DiffServ service-policy command to apply the filter to an interface if you configure the RADIUS server or 802.1X authenticator to assign the DiffServ filter. In the following example, Company XYZ uses IEEE 802.1X to authenticate all users. Contractors and temporary employees at Company XYZ are not permitted to have access to SSH ports, and data rates for Web traffic is limited. When a contractor is authenticated by the RADIUS server, the server assigns a DiffServ policy to control the traffic restrictions. The network administrator configures two DiffServ classes: cl-ssh and cl-http. The class cl-ssh matches all incoming SSH packets. The class cl-http matches all incoming HTTP packets. Then, the administrator configures a traffic policy called con-pol and adds the cl-ssh and cl-http. The policy is configured so that that SSH packets are to be dropped, and HTTP data rates are limited to 1 MB with a burst size of 64 Kbps. HTTP traffic that exceeds the limit is dropped. The host ports, ports 1–23, are configured to use MAC-based dot1x authentication to allow the DiffServ policy to be applied. Finally, the administrator configures the RADIUS server with the attribute Filter-id = “con-pol”. 536 Configuring Port and System Security To configure the switch: 1 Configure the DiffServ traffic class that matches SSH traffic. console#configure console(config)#class-map match-all cl-ssh console(config-classmap)#match srcl4port 23 console(config-classmap)#exit 2 Configure the DiffServ traffic class that matches HTTP traffic. console(config)#class-map match-all cl-http console(config-classmap)#match srcl4port 80 console(config-classmap)#exit 3 Configure the DiffServ policy. console(config)#policy-map con-pol in console(config-policy-map)#class cl-ssh console(config-policy-classmap)#drop console(config-policy-classmap)#exit console(config-policy-map)#class cl-http console(config-policy-classmap)#police-simple 1000000 64 conform-action transmit violate-action drop console(config-policy-classmap)#exit console(config-policy-map)#exit 4 Enable DiffServ on the switch. console(config)#diffserv 5 Configure information about the external RADIUS server the switch uses to authenticate clients. The RADIUS server IP address is 10.10.10.10, and the shared secret is qwerty123. console(config)#radius-server key qwerty123 console(config)#radius-server host 10.10.10.10 console(Config-auth-radius)#exit 6 Enable 802.1X on the switch. console(config)#dot1x system-auth-control 7 Create a default authentication login list and use the RADIUS server for port-based authentication for connected clients. Configuring Port and System Security 537 console(config)#aaa authentication dot1x default radius 8 Enter Interface Configuration mode for ports 1–23 and enable MACbased authentication. console(config)#interface range Gi1/0/1-23 console(config-if)#dot1x port-control mac-based 9 Set the ports to an 802.1Q VLAN. The ports must be in general mode in order to enable MAC-based 802.1X authentication. console(config-if)#switchport mode general console(config-if)#exit console(config)#exit 538 Configuring Port and System Security Port Security (Port-MAC Locking) The Port Security feature allows you to limit the number of source MAC addresses that can be learned on a port. If a port reaches the configured limit, any other addresses beyond that limit are not learned and the frames are discarded. Frames with a source MAC address that has already been learned will be forwarded. The purpose of this feature, which is also known as port-MAC locking, is to help secure the network by preventing unknown devices from forwarding packets into the network. For example, to ensure that only a single device can be active on a port, you can set the number of allowable dynamic addresses to one. After the MAC address of the first device is learned, no other devices will be allowed to forward frames into the network. When link goes down on a port, all of the dynamically locked addresses are cleared from the source MAC address table the feature maintains. When the link is restored, that port can once again learn addresses up to the specified limit. The port can learn MAC addresses dynamically, and you can manually specify a list of static MAC addresses for a port. Default 802.1X Values Table 19-2 lists the default values for the Port Security feature. Table 19-3. Default Port Security Values Feature Description Port security Unlocked Port security traps Disabled Maximum learned MAC addresses 100 (when locked) Monitor mode Disabled Configuring Port Security Configuration (Web) This section provides information about the OpenManage Switch Administrator pages for configuring and monitoring the IEEE 802.1X features and Port Security on a Dell Networking N2000, N3000, and N4000 series switches. For details about the fields on a page, click at the top of the page. Configuring Port and System Security 539 Port Security Use the Port Security page to enable MAC locking on a per-port basis. When a port is locked, you can limit the number of source MAC addresses that are allowed to transmit traffic on the port. To display the Port Security page, click Switching → Network Security → Port Security in the navigation panel. Figure 19-11. Network Security Port Security Configuring Port Security Settings on Multiple Ports To configure port security on multiple ports: 1 Open the Port Security page. 2 Click Show All to display the Port Security Table page. 3 In the Ports list, select the check box in the Edit column for the port to configure. 4 Select the desired settings for all ports that are selected for editing. 540 Configuring Port and System Security Figure 19-12. Configure Port Security Settings 5 Click Apply. Configuring Port and System Security 541 Configuring Port Security (CLI) Beginning in Privileged EXEC mode, use the following commands to enable port security on an interface to limit the number of source MAC addresses that can be learned. Command Purpose configure Enter Global Configuration mode. interface interface Enter interface configuration mode for the specified interface. The interface variable includes the interface type and number, for example tengigabitethernet 1/0/3. You can also specify a range of interfaces with the interface range command, for example, interface range tengigabitethernet 1/0/8-12 configures interfaces 8, 9, 10, 11, and 12. port security [discard] [trap seconds] Enable port security on the port. This prevents the switch from learning new addresses on this port after the maximum number of addresses has been learned. • discard — Discards frames with unlearned source addresses. This is the default if no option is indicated. • trap seconds — Sends SNMP traps and defines the minimal amount of time in seconds between two consecutive traps. (Range: 1–1000000) port security max max- addr Set the maximum number of MAC addresses that can be learned on the port while port security is enabled. CTRL + Z Exit to Privileged EXEC mode. show ports security [interface] View port security settings on all interfaces or the specified interface. show ports security addresses [interface] View the current MAC addresses that have been learned on all ports or the specified port. 542 Configuring Port and System Security 19 Captive Portal This section describes how to configure the Captive Portal feature. The topics covered in this section include: • Captive Portal Overview • Default Captive Portal Behavior and Settings • Configuring the Captive Portal (Web) • Configuring Captive Portal (CLI) • IEEE 802.1X Configuration Examples Captive Portal Overview A Captive Portal helps manage or restrict network access. Captive Portals are often used in locations that provide wired Internet access to customers, such as business centers and hotels. For example, a hotel might provide an Ethernet port in each room so that guests can connect to the Internet during their stay. The hotel might charge for Internet use, or the hotel might allow guests to connect only after they indicate that they have read and agree to the acceptable use policy. What Does Captive Portal Do? The Captive Portal feature allows you to require a user to enter login information on a custom Web page before gaining access to the network. When the user connects to the port and opens a browser, the user is presented with a welcome screen. To gain network access, the user must enter a username (for guest access) or a username and password (for authenticated access) and accept the terms of use. You can also configure the Captive Portal feature to redirect the user to another web page after successful authentication, for example your company home page. Configuring Port and System Security 543 Figure 19-13. Connecting to the Captive Portal RADIUS Server (Optional) Switch with Captive Portal Captive Portal User (Host) Default Captive Portal Welcome Screen (Displays in Captive Portal User’s Browser) The Captive Portal feature blocks hosts connected to the switch from accessing the network until user verification has been established. You can configure Captive Portal verification to allow access for both guest and authenticated users. Authenticated users must be validated against a database of authorized Captive Portal users before access is granted. The database can be stored locally on the switch or on a RADIUS server. Is the Captive Portal Feature Dependent on Any Other Feature? If you require RADIUS authentication, you must configure the RADIUS server information on the switch (see "Using RADIUS Servers to Control Management Access" on page 232). You must also configure the RADIUS attributes for Captive Portal users on the RADIUS server. For information about the RADIUS attributes to configure, see Table 19-5. For a list of RADIUS attributes that the switch supports, see "Which RADIUS Attributes Does the Switch Support?" on page 234. 544 Configuring Port and System Security You can configure the switch to send SNMP trap messages to any enabled SNMP Trap Receivers for several Captive Portal events, such as when a Captive Portal user has an authentication failure or when a Captive Portal user successfully connects to the network. If you enable the traps, the switch also writes a message to the trap log when the event occurs. To enable the Captive Portal traps, see "Configuring SNMP Notifications (Traps and Informs)" on page 351. What Factors Should Be Considered When Designing and Configuring a Captive Portal? Before enabling the Captive Portal feature, decide what type (or types) of authentication to require. Since the Dell Networking series switches support up to 10 different Captive Portal instances, you can configure one Captive Portal that requires a username and password and another that only requires the username. For each Captive Portal, you can customize the welcome screen, including the colors and logo. If you require authentication, consider the number of users that must exist in the user database. The local user database supports up to 128 users. If you need to support more than 128 authenticated users, you must use a remote RADIUS server for authentication. You can specify whether the captive portal uses HTTP or HTTPS as the protocol during the user verification process. HTTP does not use encryption during verification, and HTTPS uses the Secure Sockets Layer (SSL), which requires a certificate to provide encryption. The certificate is presented to the user at connection time. The initial Web page that a user sees when he or she connects to the Captive Portal can be customized. You can change the logo, color schemes, welcome messages, and all text on the page, including the field and button labels. The welcome page the user sees after a successful verification or authentication can also be customized. Configuring Port and System Security 545 Figure 19-14. Customized Captive Portal Welcome Screen How Does Captive Portal Work? When a port is enabled for Captive Portal, all the traffic coming onto the port from the unverified clients are dropped except for the ARP, DHCP, DNS and NETBIOS packets. These packets are allowed to be forwarded by the switch so that the unverified clients can get an IP address and are able to resolve the hostname or domain names. Data traffic from verified clients goes through as expected. If an unverified client opens a web browser and tries to connect to the network, the Captive Portal redirects all the HTTP/HTTPS traffic from the unverified clients to the authenticating server on the switch. A Captive Portal web page is sent back to the unverified client. If the verification mode for the Captive Portal associated with the port is Guest, the client can be verified without providing authentication information. If the verification mode is Local or RADIUS, the client must provide credentials that are compared against the information in the Local or RADIUS client database. After the user successfully provides the required information, the Captive Portal feature grants access to the network. What Captive Portal Pages Can Be Customized? You can customize the following three Captive Portal pages: • 546 Authentication Page —This page displays when a client attempts to connect to the network. You can customize the images, text, and colors that display on this page. Configuring Port and System Security • Logout Page — If the user logout mode is enabled, this page displays in a pop-up window after the user successfully authenticates. This window contains the logout button. • Logout Success Page — If the user logout mode is enabled, this page displays after a user clicks the logout button and successfully deauthenticates. Understanding User Logout Mode The User Logout Mode feature allows a user who successfully authenticates to the network through the captive portal to explicitly deauthenticate from the network. When User Logout Mode is disabled or the user does not specifically request logout, the connection status will remain authenticated until the Captive Portal deauthenticates the user based on the configured session timeout value. In order for the user logout feature to function properly, the client browser must have JavaScript enabled an must allow popup windows. Localizing Captive Portal Pages The Captive Portal localization feature allows you to create up to five language-specific web pages for each captive portal as long as all pages use the same verification type; either guest or authorized user web pages. This allows you to create pages in a variety of languages to accommodate a diverse group of users. To customize the pages that the user sees, click the language tab. By default, the English tab is available. The settings for the Authentication Page display. Configuring Port and System Security 547 Default Captive Portal Behavior and Settings Captive Portal is disabled by default. If you enable Captive Portal, no interfaces are associated with the default Captive Portal. After you associate an interface with the Captive Portal and globally enable the Captive Portal feature, a user who connects to the switch through that interface is presented with the Captive Portal Welcome screen shown in Figure 19-15. Figure 19-15. Default Captive Portal Welcome Screen The user types a name in the Username field, selects the Acceptance Use Policy check box, and clicks Connect to gain network access. By default, the user does not need to be defined in a database or enter a password to access the network because the default verification mode is Guest. Note that duplicate Username entries can exist in this mode because the client IP and MAC addresses are obtained for identification. Table 19-4 shows the default values for the Captive Portal feature. Table 19-4. Default Captive Portal Values Feature Value Global Captive Portal Operational Status Disabled Additional HTTP or HTTPS Ports Disabled Captive Portal can be configured to use an additional HTTP and/or HTTPS port (in support of Proxy networks). 548 Configuring Port and System Security Table 19-4. Default Captive Portal Values Feature Value Authentication Timeout 300 seconds Configured Captive Portals 1 Captive Portal Name Default Protocol Mode HTTP Verification Mode Guest URL Redirect Mode Off User Group 1-Default Session Timeout 86400 seconds Local Users None configured Interface associations None Interface status Not blocked If the Captive Portal is blocked, users cannot gain access to the network through the Captive Portal. Use this function to temporarily protect the network during unexpected events, such as denial of service attacks. Supported Captive Portal users 1024 Supported local users 128 Supported Captive Portals 10 Configuring Port and System Security 549 Configuring the Captive Portal (Web) This section provides information about the OpenManage Switch Administrator pages for configuring and monitoring Captive Portal settings on a Dell Networking N2000, N3000, and N4000 series switches. For details about the fields on a page, click at the top of the page. Captive Portal Global Configuration Use the Captive Portal Global Configuration page to control the administrative state of the Captive Portal feature and configure global settings that affect all captive portals configured on the switch. To display the Captive Portal Global Configuration page, click System → Captive Portal → Global Configuration. Figure 19-16. Captive Portal Global Configuration Captive Portal Configuration Use the Captive Portal Configuration page to view summary information about captive portals on the system, add a captive portal, and configure existing captive portals. The switch supports 10 Captive Portal configurations. Captive Portal configuration 1 is created by default and cannot be deleted. Each captive portal configuration can have unique guest or group access modes and a customized acceptance use policy that displays when the client connects. 550 Configuring Port and System Security To display the Captive Portal Configuration page, click System → Captive Portal → Configuration. Figure 19-17. Captive Portal Configuration From the Captive Portal Configuration page, click Add to create a new Captive Portal instance. Figure 19-18. Add Captive Portal Configuration Configuring Port and System Security 551 From the Captive Portal Configuration page, click Summary to view summary information about the Captive Portal instances configured on the switch. Figure 19-19. Captive Portal Summary Customizing a Captive Portal The procedures in this section customize the pages that the user sees when he or she attempts to connect to (and log off of) a network through the captive portal. These procedures configure the English version of the Default captive portal. To configure the switch: 1 From the Captive Portal Configuration page click the (English) tab.The settings for the Authentication Page display, and the links to the Captive Portal customization appear. 2 Click Download Image to download one or more custom images to the switch. You can use a downloaded custom image for the branding logo (default: Dell logo) on the Authentication Page and Logout Success page, the account image (default: blue banner with keys) on the Authentication Page, and the background image (default: blank) on the Logout Success Page. NOTE: The image to download must be accessible from your local system. The image should be 5 KB max, 200x200 pixels, GIF or JPG format. 552 Configuring Port and System Security Figure 19-20. Captive Portal Download Image Page 3 Make sure Download is selected in the Available Images menu, and click Browse. 4 Browse to the directory where the image to be downloaded is located and select the image. 5 Click Apply to download the selected file to the switch. 6 To customize the Authentication Page, which is the page that a user sees upon attempting to connect to the network, click the Authentication Page link. Configuring Port and System Security 553 Figure 19-21. Captive Portal Authentication Page 7 Select the branding image to use and customize other page components such as the font for all text the page displays, the page title, and the acceptance use policy. 8 Click Apply to save the settings to the running configuration or click Preview to view what the user will see. To return to the default views, click Clear. 554 Configuring Port and System Security 9 Click the Logout Page link to configure the page that contains the logout window. NOTE: You can configure the Logout Page settings only if the User Logout Mode is selected on the Configuration page. The User Logout Mode allows an authenticated client to deauthenticate from the network. Figure 19-22. Captive Portal Logout Page 10 Customize the look and feel of the Logout Page, such as the page title and logout instructions. 11 Click Apply to save the settings to the running configuration or click Preview to view what the user will see. To return to the default views, click Clear. 12 Click the Logout Success Page link to configure the page that contains the logout window. A user is required to logout only if the User Logout Mode is selected on the Configuration page. Figure 19-23. Captive Portal Logout Success Page Configuring Port and System Security 555 13 Customize the look and feel of the Logout Page, such as the background image and successful logout message. 14 Click Apply to save the settings to the running configuration or click Preview to view what the user will see. To return to the default views, click Clear. Local User You can configure a portal to accommodate guest users and authorized users. Guest users do not have assigned user names and passwords. Authorized users provide a valid user name and password that must first be validated against a local database or RADIUS server. Authorized users can gain network access once the switch confirms the user’s credentials. By default, each Captive Portal instance contains the default group. The default group can be renamed, or a different group can be created and assigned to each Captive Portal instance. A Captive Portal instance can be associated to one user group only. A user, however, can be assigned to multiple groups. The Local User page allows you to add authorized users to the local database, which can contain up to 128 user entries. You can also add and delete users from the local database from the Local User page. To display the Local User page, click System → Captive Portal → Local User. Figure 19-24 shows the Local User page after a user has been added. If no users have been added to the switch, many of the fields do not display on the screen. NOTE: Multiple user groups can be selected by holding the CTRL key down while clicking the desired groups. 556 Configuring Port and System Security Figure 19-24. Local User Configuration From the Local User page, click Add to add a new user to the local database. Figure 19-25. Add Local User Configuring Port and System Security 557 From the Local User page, click Show All to view summary information about the local users configured in the local database. Figure 19-26. Captive Portal Local User Summary To delete a configured user from the database, select the Remove check box associated with the user and click Apply. Configuring Users in a Remote RADIUS Server You can use a remote RADIUS server client authorization. You must add all users to the RADIUS server. The local database does not share any information with the remote RADIUS database. Table 19-5 indicates the RADIUS attributes you use to configure authorized captive portal clients. The table indicates both RADIUS attributes and vendor-specific attributes (VSA). VSAs are denoted in the Attribute column and are comma delimited (vendor ID, attribute ID). Table 19-5. Captive Portal User RADIUS Attributes Attribute Number Description Range Usage User-Name 1 User name to be authorized 1-32 characters Required None User-Password 2 User password 8-64 characters Required None 558 Configuring Port and System Security Default Table 19-5. Captive Portal User RADIUS Attributes Attribute Number Description Range Usage Default Session-Timeout 27 Logout once Integer session timeout is (seconds) reached (seconds). If the attribute is 0 or not present then use the value configured for the captive portal. Optional 0 Dell-CaptivePortal-Groups 6231, 127 A commaString delimited list of group names that correspond to the configured CP instance configurations. Optional None. The default group is used if not defined here User Group You can assign Local Users to User Groups that you create. If the Verification Mode is Local or RADIUS, you assign a User Group to a Captive Portal Configuration. All users who belong to the group are permitted to access the network through this portal. The User Group list is the same for all Captive Portal configurations on the switch. To display the User Group page, click System → Captive Portal → User Group. Configuring Port and System Security 559 Figure 19-27. User Group From the User Group page, click Add to configure a new user group. Figure 19-28. Add User Group From the User Group page, click Show All to view summary information about the user groups configured on the switch. Figure 19-29. 560 Captive Portal User Group Summary Configuring Port and System Security To delete a configured group, select the Remove check box associated with the group and click Apply. Interface Association From the Interface Association page, you can associate a configured captive portal with specific interfaces. The captive portal feature only runs on the interfaces that you specify. A captive portal can have multiple interfaces associated with it, but an interface can be associated to only one Captive Portal at a time. To display the Interface Association page, click System → Captive Portal → Interface Association. Figure 19-30. Captive Portal Interface Association NOTE: When you associate an interface with a Captive Portal, the interface is disabled in the Interface List. Each interface can be associated with only one Captive Portal at a time. Configuring Port and System Security 561 Captive Portal Global Status The Captive Portal Global Status page contains a variety of information about the Captive Portal feature. From the Captive Portal Global Status page, you can access information about the Captive Portal activity and interfaces. To display the Global Status page, click System → Captive Portal → Status → Global Status. Figure 19-31. Captive Portal Global Status Captive Portal Activation and Activity Status The Captive Portal Activation and Activity Status page provides information about each Captive Portal configured on the switch. The Captive Portal Activation and Activity Status page has a drop-down menu that contains all captive portals configured on the switch. When you select a captive portal, the activation and activity status for that portal displays. To display the Activation and Activity Status page, click System → Captive Portal → Status → Activation and Activity Status. 562 Configuring Port and System Security Figure 19-32. Captive Portal Activation and Activity Status NOTE: Use the Block and Unblock buttons to control the blocked status. If the Captive Portal is blocked, users cannot gain access to the network through the Captive Portal. Use this function to temporarily protect the network during unexpected events, such as denial of service attacks. Interface Activation Status The Interface Activation Status page shows information for every interface assigned to a captive portal instance. To display the Interface Activation Status page, click System → Captive Portal → Interface Status → Interface Activation Status. Configuring Port and System Security 563 Figure 19-33. Interface Activation Status Interface Capability Status The Interface Capability Status page contains information about interfaces that can have CPs associated with them. The page also contains status information for various capabilities. Specifically, this page indicates what services are provided through the Captive Portal to clients connected on this interface. The list of services is determined by the interface capabilities. To display the Interface Capability Status page, click System → Captive Portal → Interface Status → Interface Capability Status. Figure 19-34. 564 Interface Capability Status Configuring Port and System Security Client Summary Use the Client Summary page to view summary information about all authenticated clients that are connected through the captive portal. From this page, you can manually force the captive portal to disconnect one or more authenticated clients. The list of clients is sorted by client MAC address. To display the Client Summary page, click System → Captive Portal → Client Connection Status → Client Summary. Figure 19-35. Client Summary To force the captive portal to disconnect an authenticated client, select the Remove check box next to the client MAC address and click Apply. To disconnect all clients from all captive portals, click Delete All. Client Detail The Client Detail page shows detailed information about each client connected to the network through a captive portal. To display the Client Detail page, click System → Captive Portal → Client Connection Status → Client Detail. Configuring Port and System Security 565 Figure 19-36. Client Detail Captive Portal Interface Client Status Use the Interface Client Status page to view clients that are authenticated to a specific interface. To display the Interface Client Status page, click System → Captive Portal → Client Connection Status → Interface Client Status. Figure 19-37. Interface - Client Status Captive Portal Client Status Use the Client Status page to view clients that are authenticated to a specific Captive Portal configuration. To display the Client Status page, click System → Captive Portal → Client Connection Status → Client Status. 566 Configuring Port and System Security Figure 19-38. Captive Portal - Client Status Configuring Port and System Security 567 Configuring Captive Portal (CLI) This section provides information about the commands you use to create and configure Captive Portal settings. For more information about the commands, see the Dell Networking N2000, N3000, and N4000 Series Switches CLI Reference Guide at support.dell.com/manuals. Configuring Global Captive Portal Settings Beginning in Privileged EXEC mode, use the following commands to configure global Captive Portal settings. Command Purpose configure Enter global configuration mode. captive-portal Enter Captive Portal mode. http port port-num (Optional) Configure an additional HTTP port for Captive Portal to monitor. Use this command on networks that use an HTTP proxy server. port-num — The port number to monitor (Range: 1–65535, excluding ports 80, 443, and the configured switch management port). https port port-num (Optional) Configure an additional HTTPS port for Captive Portal to monitor. Use this command on networks that use an HTTPS proxy server. port-num — The port number to monitor Range: 1–65535, excluding ports 80, 443, and the configured switch management port). authentication timeout timeout (Optional) Configure the number of seconds the user has to enter valid credentials into the verification page. If the user exceeds the configured timeout, the verification page needs to be served again in order for the client to gain access to the network. timeout — The authentication timeout (Range: 60–600 seconds). enable 568 Globally enable the Captive Portal feature. Configuring Port and System Security Command Purpose CTRL + Z Exit to Privileged EXEC mode. show captive-portal [status] View the Captive Portal administrative and operational status. Use the status keyword to view additional global Captive Portal information and summary information about all configured Captive Portal instances. Creating and Configuring a Captive Portal Beginning in Privileged EXEC mode, use the following commands to create a Captive Portal instance and configure its settings. Command Purpose configure Enter global configuration mode. captive-portal Enter Captive Portal mode. configuration cp-id Enter the captive portal instance mode cp-id — The Captive Portal instance (Range: 1–10). The Captive Portal configuration identified by CP ID 1 is the default CP configuration. name string Add a name to the Captive Portal instance. string — CP configuration name (Range: 1–32 characters). protocol {http | https} Specify whether to use HTTP or HTTPs during the Captive Portal user verification process. verification {guest | local | radius} Specify how to process user credentials the user enters on the verification page. • guest — Allows access for unauthenticated users (users that do not have assigned user names and passwords). • local — Authenticates users against a local user database. • radius — Authenticates users against a remote RADIUS database. radius-auth-server name Specify the name of the RADIUS server to use for RADIUS verification. Use the commands described in "Using RADIUS Servers to Control Management Access" on page 232 to configure RADIUS server settings for the switch. Configuring Port and System Security 569 Command Purpose user-logout (Optional) Enable user logout mode to allow an authenticated client to deauthenticate from the network. If this option is clear or the user does not specifically request logout, the client connection status remains authenticated until the CP deauthenticates the user, for example by reaching the idle timeout or session timeout values. redirect (Optional) Enable the redirect mode for a Captive Portal configuration so that the user is redirected to a specific Web page after the verification or authentication process. When the redirect mode is not enabled, the user sees the Captive Portal welcome page after the verification or authentication process. redirect-url url (Optional) Specify the web page that the users sees after successful verification or authentication through the Captive Portal. url — The URL for redirection (Range: 1–512 characters). group group-number (For Local and RADIUS verification) Configure the group number associated with this Captive Portal configuration. By default, only the default group exists. To assign a different user group to the Captive Portal instance, you must first configure the group. group-number — The number of the group to associate with this configuration (Range: 1–10) session-timeout timeout (Optional) Enter the number of seconds to wait before terminating a session. A user is logged out once the session timeout is reached. You can also set the session timeout for each user if the Captive Portal requires authentication. timeout — Session timeout. 0 indicates timeout not enforced (Range: 0–86400 seconds) interface interface Associate an interface with this Captive Portal. ( The interface variable includes the interface type and number, for example tengigabitethernet 1/0/3. enable 570 Enable the Captive Portal instance. Configuring Port and System Security Command Purpose block (Optional) Block all traffic for a Captive Portal configuration. If the Captive Portal is blocked, users cannot gain access to the network through the Captive Portal. Use this function to temporarily protect the network during unexpected events, such as denial of service attacks. CTRL + Z Exit to Privileged EXEC mode. show captive-portal configuration cp-id [status | interface] View summary information about a Captive Portal instance. • cp-id — The Captive Portal instance (Range: 1–10). • status — View additional information about the Captive Portal instance. • interface — View information about the interface(s) associated with the specified Captive Portal. show captive-portal interface configuration cp-id status View information about the interfaces associated with the specified Captive Portal instance. cp-id — The Captive Portal instance (Range: 1–10). NOTE: To return the default Captive Portal instance to its default values, use the clear command in the Captive Portal Instance mode. You must also use the no interface interface command to remove any associated interfaces from the instance. Configuring Captive Portal Groups and Users Beginning in Privileged EXEC mode, use the following commands to create a Captive Portal group. You can use the default group, or you can create a new group. Command Purpose configure Enter global configuration mode. captive-portal Enter Captive Portal mode. Configuring Port and System Security 571 Command Purpose user group group-id [name name] Configure a group. Each Captive Portal that requires authentication has a group associated with it. Only the users who are members of that group can be authenticated if they connect to the Captive Portal. • group-id — Group ID (Range: 1–10). • name — Group name (Range: 1–32 characters). user user-id name name Create a new user for the local user authentication database. • user-id —User ID (Range: 1–128). • name —user name (Range: 1–32 characters). user user-id password Configure the password for the specified user. • user-id —User ID (Range: 1–128). • password —User password (Range: 8–64 characters). password user user-id group group- Associate a group with a Captive Portal user. A user can be id associated with more than one group. • user-id — User ID (Range: 1–128). • group-id — Group ID (Range: 1–10). user user-id sessiontimeout timeout Enter the number of seconds to wait before terminating a session for the specified user. The user is logged out once the session timeout is reached. • user-id — User ID (Range: 1–128). • timeout — Session timeout. 0 indicates timeout not enforced (Range: 0–86400 seconds) user group group-id (Optional) Move all of the users in a group to a different moveusers new-group-id group. This command removes the users from the group specified by group-id. • group-id — Group ID (Range: 1–10). • new-group-id — Group ID (Range: 1–10). CTRL + Z Exit to Privileged EXEC mode. show captive-portal user View summary information about all users configured in [user-id] the local database. Specify the user ID to view additional information about a user. user-id — User ID (Range: 1–128). 572 Configuring Port and System Security Command Purpose clear captive portal users (Optional) Delete all captive portal user entries from the local database. Managing Captive Portal Clients The commands in this section are all executed in Privileged EXEC mode. Use the following commands to view and manage clients that are connected to a Captive Portal. Command Purpose show captive-portal configuration [cp-id] client status Display information about the clients authenticated to all Captive Portal configurations or a to specific configuration. cp-id — The Captive Portal instance (Range: 1–10). show captive-portal Display information about clients authenticated on all interface interface client interfaces or no a specific interface. status interface — Specific Ethernet interface, such as gi1/0/8. show captive-portal client [macaddr] status Display client connection details or a connection summary for connected Captive Portal users. macaddr — The MAC address of the client. captive-portal client Deauthenticate a specific captive portal client. deauthenticate macaddr macaddr — The MAC address of the client. Configuring Port and System Security 573 Captive Portal Configuration Example The manager of a resort and conference center needs to provide wired Internet access to each guest room at the resort and in each conference room. Due to legal reasons, visitors and guests must agree to the resort’s acceptable use policy to gain network access. Additionally, network access from the conference rooms must be authenticated. The person who rents the conference room space receives a list username and password combinations upon arrival. Hotel employees have their own Captive Portal. The network administrator for the resort and conference center decides to configure the three Captive Portals Table 19-6 describes. Table 19-6. Captive Portal Instances Captive Portal Name Description Guest Free Internet access is provided in each guest room, but guests must enter a name and agree to the acceptable use policy before they can gain access. The manager wants guests to be redirected to the resort’s home web page upon successful verification. No logout is required. Conference Because physical access to the conference rooms is less secure than access to each guest room, the manager wants to ensure that people who connect to the network through a port in a conference room are authenticated. The Conference Captive Portal uses the local database for authentication. Employee To gain network access, resort employees must enter a username and password that is stored on a RADIUS server. Configuration Overview The following steps provide an overview of the process you use to configure the Captive Portal feature. To configure the switch: 1. If you plan to use a RADIUS server for authentication, configure the RADIUS server settings on the switch. 2. If authentication is required, configure the user groups to associate with each Captive Portal. 3. Create (add) the Captive Portals. 574 Configuring Port and System Security 4. Configure the Captive Portal settings for each Captive Portal, such as the verification mode. 5. Associate interfaces with the Captive Portal instances. 6. Download the branding images, such as the company logo, to the switch. The images you download must be accessible from the switch, either on the system you use to manage the switch or on a server that is on the same network as the switch. NOTE: You must use the web interface to download images. 7. Customize the authentication, logout, and logout success web pages that a Captive Portal user will see. Dell recommends that you use Use Dell OpenManage Administrator to customize the Captive Portal authentication, logout, and logout success pages. A Preview button is available to allow you to see the pages that a Captive Portal user will see. 8. If you use the local database for user authentication, configure the users on the switch. 9. If you use a RADIUS server for authentication, add the users to the database on the RADIUS server. 10. Associate interfaces with the Captive Portal instances. 11. Globally enable Captive Portal. Detailed Configuration Procedures Use the following steps to perform the Captive Portal configuration: 1. Configure the RADIUS server information on the switch. In this example, the RADIUS server IP address is 192.168.2.188, and the RADIUS server name is luxury-radius. console#configure console(config)#radius-server host 192.168.12.182 console(Config-auth-radius)#name luxury-radius console(Config-auth-radius)#exit 2. Configure the Captive Portal groups. Configuring Port and System Security 575 console(config)#captive-portal console(config-CP)#user group 2 name Conference console(config-CP)#user group 3 name Employee console(config-CP)#exit 3. Configure the Guest Captive Portal. console(config)#captive-portal console(config-CP)#configuration 2 console(config-CP 2)#name Guest console(config-CP 2)#redirect console(config-CP 2)#redirect-url http://www.luxuryresorturl.com console(config-CP 2)#interface te1/0/1 console(config-CP 2)#interface te1/0/2 ... console(config-CP 2)#interface te1/0/4 console(config-CP 2)#exit 4. Configure the Conference Captive Portal. console(config-CP)#configuration 3 console(config-CP 3)#name Conference console(config-CP 3)#verification local console(config-CP 3)#group 2 console(config-CP 4)#interface te1/0/825 ... console(config-CP 4)#interface te1/0/1533 console(config-CP 3)#exit 5. Configure the Employee Captive Portal. console(config-CP)#configuration 4 console(config-CP 4)#name Employee console(config-CP 4)#verification radius console(config-CP 4)#group 3 console(config-CP 4)#interface te1/0/1834 ... console(config-CP 4)#interface te1/0/2240 console(config-CP 4)#exit 576 Configuring Port and System Security 6. Use the web interface to customize the Captive Portal pages that are presented to users when they attempt to connect to the network. NOTE: Captive Portal page customization is supported only through the Web interface. For information about customizing the Captive Portal pages, see "Customizing a Captive Portal" on page 552. 7. Add the Conference users to the local database. console(config-CP)#user 1 name EaglesNest1 console(config-CP)#user 1 password Enter password (8 to 64 characters): ********* Re-enter password: ********* console(config-CP)#user 1 group 2 Continue entering username and password combinations to populate the local database. 8. Add the User-Name, User-Password, Session-Timeout, and Dell-CaptivePortal-Groups attributes for each employee to the database on the RADIUS server. 9. Globally enable the Captive Portal. console(config-CP)#enable Configuring Port and System Security 577 Authentication Manager Overview The Authentication Manager supports the hierarchical configuration of host authentication methods on an interface. Dell switches support the following host authentication methods: • IEEE 802.1x • MAC Authentication Bypass • Captive portal Using the Authentication Manager, the administrator can configure an authentication method list on a per-port basis. Authentication can be enabled or disabled. If authentication is disabled, then no authentication method is applied and the port is provided with open access. The default behavior is that authentication is disabled for all ports. The configured authentication methods are attempted in the configured order. If an authentication method times out, then the next configured method is attempted. If an authentication method fails, then the next method is not attempted and authentication begins again from the first method. If all the methods fail, then the Authentication Manager starts a timer for reauthentication. Failure in this context means that host authentication was attempted and the host was unable to successfully authenticate. At the expiry of the timer, the Authentication Manager starts the authentication process again from the first method in the list. The Authentication Manager supports configuring a priority for each authentication method on a port. The authentication priority allows a higher priority method (not currently running) to interrupt an authentication in progress with a lower-priority method. If a client is already authenticated, an interrupt from a higher-priority method can cause a client previously authenticated using a lower priority method to reauthenticate. By default, Dell switches are configured with a method list that contains the methods (in order) Dot1x, MAB, and captive portal (web-auth) as the default methods for all the ports. Dell switches restrict the configuration such that no method is allowed to follow the captive portal method, if configured. 578 Configuring Port and System Security When a client is connected to a port, the switch tries to authenticate the user/client using the methods in configuration order. If any authentication method times out (an error), then the next authentication method is tried. If all authentication methods configured for the port error out, the switch starts a timer whose value is equal to the authentication restart timer. At the expiry of the timer, the switch restarts the authentication process from the first method. This timer starts only when all of the authentication methods error out. The authentication manager controls only the order in which the authentication methods are executed. The switch administrator is responsible for implementing the required configuration for the respective methods to authenticate successfully. Authentication Restart Authentication restarts from the first configured method on any of the following events: • Link flap • Authentication fails for all configured methods • Authentication priority (802.1X packet received when a lower priority method is active) 802.1X Interaction By default, 802.1X drops all traffic prior to successful 802.1X (or MAB) authentication. If captive portal is configured as a method, authentication allows certain traffic types, such as DHCP or DNS, access to the network during the captive portal method invocation. Authentication Priority The default authentication priority of a method is equivalent to its position in the order of the authentication list. If authentication method priorities are not configured, then the relative priorities (first is highest) are in the same order as that of the per-port based authentication list. Configuring Port and System Security 579 Authentication priority allows a higher-priority method (not currently running) to interrupt an authentication in progress with a lower-priority method. Alternatively, if the client is already authenticated, an interrupt from a higher-priority method can cause a client, which was previously authenticated using a lower-priority method, to reauthenticate. For example, if a client is already authenticated using a method other than 802.1X (MAB or captive portal) and 802.1X has higher priority than the authenticated method, and if an 802.1X frame is received, then the existing authenticated client is removed and the authentication process begins again from the first method in the order. If 802.1X has a lower priority than the authenticated method, then the client is not removed and the 802.1X frames are ignored. If administrator changes the priority of the methods, then all the users who are authenticated using a lower-priority method are forced to reauthenticate. If an authentication session is in progress and the administrator changes the order of the authentication methods, then the configuration will take effect for the next session onwards. Configuration Example—802.1X and MAB In this scenario, the authentication manager selects the first authentication method, 802.1X. If authentication using 802.1X is successful, then the client is allowed network access. If authentication using 802.1X errors out, then authentication manager selects the next authentication method: MAB. If authentication using MAB returns an error, then the port is unauthorized. The authentication manager will start a timer to re-authenticate the client. At the expiry of the timer, the authentication manager restarts authentication by selecting the 802.1X method. console#configure console(config)#radius-server host 10.10.10.10 console(Config-radius)#name BigRadius console(Config-radius)#primary console(Config-radius)#usage 802.1x console(Config-radius)#exit console(config)#radius-server key thatsyoursecret-keepit-keepit console(config)#authentication enable console(config)#aaa authentication dot1x default radius console(config)#dot1x system-auth-control console(config)#interface te1/0/4 console(config-if-Te1/0/4)#authentication order dot1x mab 580 Configuring Port and System Security console(config-if-Te1/0/4)#dot1x reauthentication console(config-if-Te1/0/4)#dot1x port-control mac-based console(config-if-Te1/0/4)#dot1x mac-auth-bypass console(config-if-Te1/0/4)#exit Configuring Port and System Security 581 Denial of Service Denial of Service (DoS) refers to the exploitation of a variety of vulnerabilities which would interrupt the service of a host or make a network unstable. Use the Denial of Service page to configure settings to help prevent DoS attacks. DoS protection is disabled by default. To display the Denial of Service page, click System → Management Security → Denial of Service in the navigation panel. Figure 19-39. 582 Denial of Service Configuring Port and System Security 20 Configuring Access Control Lists This chapter describes how to configure Access Control Lists (ACLs), including IPv4, IPv6, and MAC ACLs. This chapter also describes how to configure time ranges that can be applied to any of the ACL types. The topics covered in this chapter include: • ACL Overview • ACL Configuration Details • Policy Based Routing • Configuring ACLs (Web) • Configuring ACLs (CLI) • ACL Configuration Examples ACL Overview Access Control Lists (ACLs) are a collection of rules that provide security by blocking selected packets from ingressing the switch. ACLs are implemented in hardware and processed at line rate for the front-panel ports. A reduced functionality set of ACLs is implemented in firmware for the OOB port. ACLs can also provide traffic rate limiting and decide which types of traffic are forwarded or blocked. ACLs can reside in a firewall router, a router connecting two internal networks, or a Layer 3 switch, such as a Dell Networking N2000, N3000, and N4000 series switches. You can also create an ACL that limits access to the management interfaces based on the connection method (for example, Telnet or HTTP) and/or the source IP address. The Dell Networking series switches support ACL configuration in both the ingress and egress direction. Egress ACLs provide the capability to implement security rules on the egress flows (traffic leaving a port) rather than the ingress flows (traffic entering a port). Ingress and egress ACLs can be applied to any physical port, port-channel (LAG), or VLAN routing port. Configuring Access Control Lists 583 Depending on whether an ingress or egress ACL is applied to a port, when the traffic enters (ingress) or leaves (egress) a port, the ACL compares the criteria configured in its rules, in list order, to the fields in a packet or frame to check for matching conditions. The ACL processes the traffic based on the actions contained in the rules. ACL rules are processed in list order, from the first to the last rule in the list. If a matching rule is found, the rule action is taken and no subsequent rules in the list are processed for that packet. Frequently matched rules should be placed near or at the front of the list. A list must have at least one permit entry or all traffic is denied (dropped). Egress ACLs filter switched traffic only. Packets generated by the switch are sent regardless of any egress ACL deny rules. NOTE: The last access group configured is terminated by an implicit deny all rule, which drops any packet not matching a preceding rule. You can set up ACLs to control traffic at Layer 2, Layer 3, or Layer 4. MAC ACLs operate on Layer 2. IP ACLs operate on Layers 3 and 4. Dell Networking series switches support both IPv4 and IPv6 ACLs. What Are MAC ACLs? MAC ACLs are Layer 2 ACLs. You can configure the rules to inspect the following fields of a packet: • Source MAC address • Source MAC mask • Destination MAC address • Destination MAC mask • VLAN ID • Class of Service (CoS) (802.1p) • EtherType L2 ACLs can apply to one or more interfaces. Multiple access lists can be applied to a single interface; sequence number determines the order of execution. 584 Configuring Access Control Lists MAC access list actions include CoS queue assignment, mirroring, redirection to another port, and logging, as well as the usual permit and deny actions. What Are IP ACLs? IP ACLs classify for Layers 3 and 4 on IPv4 or IPv6 traffic. Each ACL is a set of up to 100 rules applied to inbound or outbound traffic. IP ACLs support logging, redirect, mirroring, and drop. The following fields may be specified in the permit or deny rules. • Destination IP with wildcard mask • Destination L4 port • Every protocol or a specific protocol • IP DSCP • IP precedence • IP TOS • TCP flags • Source IP with wildcard mask • Source L4 port, with eq, ne, gt, and lt operators and ranges (IP/TCP/UDP packets only) • Destination layer 4 port, with eq, ne, gt, and lt operators and ranges (IP/TCP/UDP packets only) What Is the ACL Redirect Function? The redirect function allows traffic that matches a permit rule to be redirected to a specific physical port or LAG instead of processed on the original port. A packet that is redirected does not go through the normal forwarding process. It is sent to the redirect target port. The redirect function and mirror function are mutually exclusive. In other words, you cannot configure a given ACL rule with both mirror and redirect attributes. What Is the ACL Mirror Function? ACL mirroring provides the ability to mirror traffic that matches a permit rule to a specific physical port or LAG. Mirroring is similar to the redirect function, except that in flow-based mirroring a copy of the permitted traffic is Configuring Access Control Lists 585 delivered to the mirror interface while the packet itself is forwarded normally through the device. You cannot configure a given ACL rule with both mirror and redirect attributes. Using ACLs to mirror traffic is considered to be flow-based mirroring since the traffic flow is defined by the ACL classification rules. This is in contrast to port mirroring, where all traffic encountered on a specific interface is replicated on another interface. What Is ACL Logging ACL Logging provides a means for counting the number of “hits” against an ACL rule. When you configure ACL Logging, you augment the ACL deny rule specification with a "log" parameter that enables hardware hit count collection and reporting. The switch uses a fixed five minute logging interval, at which time trap log entries are written for each ACL logging rule that accumulated a non-zero hit count during that interval. You cannot configure the logging interval. What Are Time-Based ACLs? The time-based ACL feature allows the switch to dynamically apply an explicit ACL rule within an ACL for a predefined time interval by specifying a time range on a per-rule basis within an ACL, so that the time restrictions are imposed on the ACL rule. With a time-based ACL, you can define when and for how long an individual rule of an ACL is in effect. To apply a time to an ACL, first you define a specific time interval and then apply it to an individual ACL rule so that it is operational only during the specified time range, for example, during a specified time period or on specified days of the week. A time range can be absolute (specific time) or periodic (recurring). If an absolute and periodic time range entry are defined within the same time range, the periodic timer is active only when the absolute timer is active. NOTE: Adding a conflicting periodic time range to an absolute time range will cause the time range to become inactive. For example, consider an absolute time range from 8:00 AM Tuesday March 1st 2011 to 10 PM Tuesday March 1st 2011. Adding a periodic entry using the 'weekend' keyword will cause the time-range to become inactive because Tuesdays are not on the weekend. 586 Configuring Access Control Lists A named time range can contain up to 10 configured time ranges. Only one absolute time range can be configured per time range. During the ACL configuration, you can associate a configured time range with the ACL to provide additional control over permitting or denying a user access to network resources. Benefits of using time-based ACLs include: • Providing more control over permitting or denying a user access to resources, such as an application (identified by an IP address/mask pair and a port number). • Providing control of logging messages. Individual ACL rules defined within an ACL can be set to log traffic only at certain times of the day so you can simply deny access without needing to analyze many logs generated during peak hours. What Are the ACL Limitations? There are two hardware matching engines visible to the Dell switch administrator: the ingress processor and the egress processor. Each of these processors has different limits and actions. The ingress matching engine processes packets on ingress to the switch and can apply actions such as applying CoS processing, diverting to a different port, etc. The egress matching engine processes packets after they are switched and queued for egress and supports policies such as rewriting the DSCP or CoS values, as well as the normal permit (forward) and deny (drop) actions. ACLs operate by matching on specific fields within packets. Various match conditions (operators) are supported (e.g., equal, less than, not equal, etc.), along with masks that support selection of all or a portion of a field. Each field to be matched is assigned to a matching engine (slice). A slice is defined by an offset into the packet that is compared against a set of matching values and masks along with an associated action (ACEs). Each Dell Networking switch series supports a fixed number of slices and each slice supports a fixed number of matching criteria (values and masks). Slices operate in parallel to perform the configured matching operations. An ACL with a different offset requires the use of a new hardware slice but multiple matching values can be specified for a single slice (e.g., an IPv4 destination address with a 32-bit mask is 192.168.21.1 or 192.168.12.3). Slices can also be joined together to match widths larger than 32 bits or they can be concatenated to provide a larger number of matching values with a single offset. In general, ACLs that match Configuring Access Control Lists 587 on less than 32 bits will be expanded internally to match on 32 bits with a variable mask. This allows other ACLs using the same offset to utilize the same slice with potentially different masks and match values. The user interface limits for ACLs are 1023 rules per access list and 100 access lists. The switch automatically combines slices to operate in parallel over greater field widths (e.g., IPv6 source address) or combines slices to supply more match conditions (IPv4 destination address equal to multiple ranges of addresses). In the case of a match condition specifying a 128-bit IPv6 address, additional slices are assigned to operate in parallel on specific portions of the address. This reduces the overall number of slices available to match on other key fields. The switch attempts to assign slices to match conditions in an optimal manner; however, combinations of match conditions can reduce the maximum number of ACLs that can be configured to fewer than the published limits. As an example, the smallest IPv6 QoS match will take 6 slices from the switch. The N4000 switches support the following hardware limits: • 2047 ingress rules and 1023 egress rules, for a total of 3072 rules. • The hardware has 10 ingress slices and 4 egress slices, with 4 ingress slices having a depth of 128 rules, and 6 ingress slices having a depth of 256 rules. The egress slices have a depth of 256 rules. The N3000 switches support the following hardware limits: • 3072 ingress rules and 1024 egress rules, for a total of 4096 rules. • The hardware has 14 ingress slices and 4 egress slices, with the 14 ingress slices having a depth of 256 rules. The egress slices have a depth of 256 rules. The N2000 switches support the following hardware limits: • 1024 ingress rules and 512 egress rules, for a total of 1536 rules. • The hardware has 14 ingress slices and 4 egress slices, with the 14 ingress slices having a depth of 256 rules. The egress slices have a depth of 256 rules. The software limits are shown in Table 20-1: 588 Configuring Access Control Lists Table 20-1. ACL Software Limits Limitation N2000 N3000 N4000 Maximum Number of ACLs (any type) 100 100 100 Maximum Number Configurable Rules per List 1023 1023 1023 Maximum ACL Rules per Interface 1024 ing/ and Direction (IPv4/L2) 512 egr 3072 ing/ 1024 egr 2047 ing/ 1023 egr Maximum ACL Rules per Interface 512 ing/ and Direction (IPv6) 256 egr 1021 ing/ 512 egr 1021 ing/ 512 egr Maximum ACL Rules (systemwide) 2048 4096 3072 Maximum VLAN interfaces with ACLs applied 24 24 24 Maximum ACL Logging Rules (system-wide) 128 128 128 Please note the following additional limitations on ingress and egress ACLs: • You can configure mirror or redirect attributes for a given ACL rule, but not both. • The Dell Networking series switches support a limited number of counter resources, so it may not be possible to log every ACL rule. You can define an ACL with any number of logging rules, but the number of rules that are actually logged cannot be determined until the ACL is applied to an interface. Furthermore, hardware counters that become available after an ACL is applied are not retroactively assigned to rules that were unable to be logged (the ACL must be disassociated from the interface and then reassociated). Rules that are unable to be logged are still active in the ACL for purposes of permitting or denying a matching packet. If console logging is enabled and the severity is set to a numerically lower severity than the console severity setting, a log entry may appear on the screen. Configuring Access Control Lists 589 • The order of the rules is important: when a packet matches multiple rules, the first rule takes precedence. Once a packet has matched a rule, the corresponding action is taken and no further attempts to match the packet are made. Also, once you define an ACL for a given port, all traffic not specifically permitted by the ACL is denied access. • Egress (out) ACLs only affect switched/routed traffic. They have no effect on packets generated locally by the switch, e.g., LACPDUs or spanning tree BPDUs. • Ingress ACLs filter packets before they are processed by the switching fabric. Egress ACLs filter packets after they have been processed by the switching fabric. • User-defined ingress ACLs are prioritized before system ACLs. Userdefined ingress ACLs that match control plane packets such as BPDUs interfere with switch operation. • Port ranges are not supported for egress ACLs for either IPv4 or IPv6 ACLs. • The fragments and routing keywords are not supported for egress IPv6 ACLs. The fragments keywords is not supported on IPv4 egress ACLs. • On the N4000 switches, the IPv6 ACL routing keyword is not supported when any IPv6 address is specified. The routing keyword is not support for IPv4 ACLs. • On the N4000 switches, the IPv6 ACL fragment keyword matches only on the first two IPv6 extension headers for the fragment header (next header code 44). If the fragment header appears in the third or subsequent header, it is not matched • On the N2000 and N3000 switches, the IPv6 ACL fragment keyword matches only on the first IPv6 extension header (next header code 44). If the fragment header appears in the second or subsequent header, it is not matched. • The IPv6 ACL routing keyword matches only on the first IPv6 extension header (next header code 43). If the fragment header appears in the second or subsequent header, it is not matched. NOTE: The actual number of ACLs and rules supported depends on the resources consumed by other processes and configured features running on the switch. 590 Configuring Access Control Lists ACL Configuration Details How Are ACLs Configured? To configure ACLs, follow these steps: 1 Create a MAC ACL by specifying a name. 2 Create an IP ACL by specifying a number. 3 Add new rules to the ACL. 4 Configure the match criteria for the rules. 5 Apply the ACL to one or more interfaces. Editing Access Lists When editing access lists, new entries are added to the end of the list. There is an implicit deny all statement at the end of every access-group that is not shown and is not editable. To insert a rule in the middle of an ACL, you must delete the list, and then add the rules again, in order, with the newly included entry. One way to manage this process is to show the running config, copy the access list to an editor, edit the list offline, delete the access list on the switch, and then paste the updated access list back into the switch console. NOTE: When configuring access lists, complete checks are made only when the access list is applied to an active interface. It is recommended that you configure and test an access list on an active (up) interface prior to deploying it on links in the production network. If an ACL is configured on an interface that is not up, error messages regarding ACL resource allocation may be logged when the interface is brought up. Preventing False ACL Matches Be sure to specify ACL access-list, permit, and deny rule criteria as fully as possible to avoid false matches. This is especially important in networks with protocols that have different frame or EtherType values. For example, L3 ACL rules that specify a TCP or UDP port value should also specify the TCP or UDP protocol. MAC ACL rules that specify an EtherType value for the frame should also specify a source or destination MAC address wherever possible. Configuring Access Control Lists 591 In general, any rule that specifies matching on an upper-layer protocol field should also include matching constraints for as many of the lower-layer as where possible. For example, a rule to match packets directed to the wellknown UDP port number 22 (SSH) should also include matching constraints on the IP protocol field (protocol=0x11 or UDP) and the source or destination IP address. Table 20-2 lists commonly-used EtherTypes numbers: Table 20-2. Common EtherType Numbers EtherType Protocol 0x0800 Internet Protocol version 4 (IPv4) 0x0806 Address Resolution Protocol (ARP) 0x0842 Wake-on LAN Packet 0x8035 Reverse Address Resolution Protocol (RARP) 0x8100 VLAN tagged frame (IEEE 802.1Q) 0x86DD Internet Protocol version 6 (IPv6) 0x8808 MAC Control 0x8809 Slow Protocols (IEEE 802.3) 0x8870 Jumbo frames 0x888E EAP over LAN (EAPOL – 802.1x) 0x88CC Link Layer Discovery Protocol 0x8906 Fibre Channel over Ethernet 0x9100 Q in Q Figure 20-3 lists commonly-used IP protocol numbers: Table 20-3. Common IP Protocol Numbers IP Protocol Number Protocol 0x00 IPv6 Hop-by-hop option 0x01 ICMP 0x02 IGMP 0x06 TCP 592 Configuring Access Control Lists Table 20-3. Common IP Protocol Numbers (Continued) IP Protocol Number Protocol 0x08 EGP 0x09 IGP 0x11 UDP Using IP and MAC Address Masks Masks are used with IP and MAC addresses to specify what should be considered in the address for a match. Masks are expanded internally into a bit mask and are applied bit-wise in the hardware even though they are entered in decimal or hexadecimal format. Masks need not have contiguous 0 or 1 bits. A 0 bit value in the mask indicates that the address field in the packet being compared must match the address bit exactly. A 1 value in the mask indicates a wildcard or don't care value, i.e. the access bits are not compared and match any possible value. For example, an IP address of 3.3.3.3 with a mask of 0.0.0.0 indicates that the ACL matches on all four bytes of the IP address. Likewise, a MAC address of 68:94:23:AD:F3:18 with a mask of 00:00:00:00:00:ff indicates that the first five bytes must match (e.g., 68:94:23:AD:F3) and the last byte may take on any value from 0x00 to 0xff (0–255) and still be considered a match. The following ACL equivalents are noted: Address Mask Equivalent Address 0.0.0.0 255.255.255.255 any x.x.x.x host x.x.x.x 0:0:0:0:0:0 ff:ff:ff:ff:ff:ff any Configuring Access Control Lists 593 Policy Based Routing Overview In contemporary inter-networks, network administrators often need to implement packet routing according to specific organizational policies. Policy Based Routing (PBR) exactly fits this purpose. PBR provides a flexible mechanism to implement solutions where organizational constraints dictate that traffic be routed through specific network paths. PBR does not affect route redistribution that occurs via routing protocols. PBR is a true routing solution. The packet TTL is decremented in PBRrouted packets. The destination MAC is rewritten in PBR routed packets. ARP lookups are sent when required for unresolved next hop addresses. PBR routed packets are routed via routing table lookups. Routes must exist in the routing table for PBR next-hop and default next-hop rules. Configuring PBR consists of installing a route-map with match and set commands, and then applying the corresponding route-map to the interface. IP routing must be enabled on the interfaces and globally. PBR is applied to inbound traffic on IP routing interfaces. Enabling the feature causes the router to analyze packets entering the interface using a route-map. A VLAN can only have one associated route-map, but the administrator can configure multiple route-map entries in the route-map with different sequence numbers. Packets entering the interface are filtered by a user-selected ACL. Packets that are allowed by the ACL are evaluated in order of increasing sequence number until a viable routing destination is found. Other actions may also be specified. If no action is executed, packets are routed via normal routing table lookup. ACLs present in a route-map’s match clauses inherit the ordering of the containing route-map sequence number. Therefore, it is recommended that ACLs used in route-map match clauses be independent of ACLs used in access-groups in order to preserve access-group ordering. A route-map rule may be configured as a permit or deny rule. If the rule is marked as deny, traditional destination-based routing is performed on the packet meeting the ACL match criteria. If the rule is marked as permit, and if the packet meets the ACL match criteria, then the action specified by the set commands in the route-map statement are evaluated. If no active route is found in the route-map, the packet is forwarded using traditional destination594 Configuring Access Control Lists based routing. If the network administrator instead wants to drop a packet that does not match the specified criteria, a set statement must be configured to route the packet to interface null0 as the last entry in the route-map. Deny route-maps forward packets with matching ACL criteria using normal route table lookups. If an associated ACL rule is marked as deny, traditional destination-based routing is performed on the packet meeting the match criteria. A set clause is required in a deny route map for it to be processed. Route-maps may specify multiple packet attributes in match statements. These attributes can be matched through a “match” clause based on the length of the packet or a “match” clause linked with an ACL. The following packet attributes are supported to classify L3 routed traffic for PBR: • • • MAC access list (match mac-list) – Source MAC address – 802.1p priority IP access list (match ip address) – Source or destination IP address – Source or destination TCP/UDP port L3 packet length in the IP header (match length) The Policy Based Routing feature overrides the normal routing decisions taken by the router and attempts to route the packet using the criteria in the set clause: • List of next hop IP addresses — The set ip next-hop command checks for the next-hop address in the routing table, and if the next-hop address is present and active in the routing table, then the policy routes the ACL matching packets to the next hop. If the next hop is not present in the routing table, the command uses the normal routing table to route the packet. Non-matching packets are routed using the normal routing table. The IP address must specify an adjacent next-hop router in the path toward the destination to which the packets should be routed. The first available IP address associated with a currently active routing entry is used to route the packets. This type of rule takes priority over explicit routing entries in the routing table, but not default routing entries. Configuring Access Control Lists 595 • List of default next hop IP addresses — The set ip default next-hop command checks the list of destination IP addresses in the routing table and, if there is no explicit route for the packet's destination address in the routing table, the next-hop destinations in the rule are evaluated, and packets are routed to the first available next hop. Packets that do not match are routed using the routing table default. A default route in the routing table is not considered an explicit route for an unknown destination address. This type of rule takes priority over default entries in the routing table but is processed after explicit routing table entries. • IP precedence — Packets matching the criteria have their IP precedence rewritten. The IP precedence value is the four ToS bits in the IP packet header. Limitations Set Clause Required Route-map deny/permit statements without “set” clauses are ignored. No Implicit “deny all” Rule When an access-group is applied to an interface, an implicit rule of “deny all” is applied after the last access-group on the interface. When match rules in an ACL associated with a permit route-map are successful, the packets are considered as candidates to be routed according to the set clauses specified in the route-map. If none of the permit rules match, then the packet is routed by the standard L3 routing process. The implicit “deny all” rule is not applicable to ACLs associated with “permit” route-maps. Black Holes Possible If the next hop specified by a policy based rule is not reachable, packets matching the rule are routed using the routing table. If the routing table does not supply a route to the destination, then the packets are lost. If a set interface Null0 clause is present in the policy map, the packets are dropped. The set interface null0 command can also be used to drop undesirable or unwanted traffic, i.e., to create a black hole route. 596 Configuring Access Control Lists Resource-Sharing Between ACLs and PBR ACLs associated with a route-map and general ACLs share the same hardware resources. If PBR consumes the maximum number of HW resources on an interface or system-wide, general purpose ACLs cannot be configured and vice versa. Hardware allocation is performed on a first-come, first-serve basis. Counter Support for Route-map ACL A counter is associated with each ACL rule associated with a route-map. The counter indicates how many packets were policy routed. There is no provision to nondestructively clear these counters from the UI. Counters associated with a route-map statement are cleared when the route-map is removed from the VLAN. The hardware does not support both a counter and a rate-limit. Therefore, the system does not support configuring ACLs with a rate-limit being used for PBR. Priority of ACL/PBR Rules When Applied to Hardware Each ACL normally is associated with a sequence number that indicates the order in which an ACL needs to be applied when multiple ACLs are applied on a single VLAN. The sequence number or priority indicates the order in which ACLs (and corresponding rules associated with ACLs) are applied. When an ACL is used in a route-map's “match” clause, it is applied to hardware with the same priority as if it were an independent ACL, but with the exception of the implicit “deny all” rule. A route-map may have multiple statements with different sequence numbers associated with each ACL entry. In this case, the ACL inherits the sequence number of the route-map entry. Therefore, it is advisable to segregate ACLs used in route-maps from ACLs applied directly to interfaces. ACL Resource Usage When a route-map defines a “match” rule associated with an ACL, except for the implicit routing behavior mentioned above, the resource consumption is the same as if a normal ACL is applied on an interface. Rules consumed by an ACL corresponding to a route-map “match” clause share hardware resources with the ACL component. Certain resources cannot be shared. For example, the rate-limit clause cannot be utilized in a PBR ACL, as the hardware cannot support both a counter (allocated by every PBR route-map) and a rate limit. Resources are not consumed until the route-map is associated with an Configuring Access Control Lists 597 interface. Changes to an existing route-map associated with an interface (or to the associated ACLs) do not take effect until the route-map is reapplied to the interface. ACL Resource Sharing An ACL rule contains match and action attributes. For example, an ACL rule may have a match clause on the source IP address and action attributes independent of PBR, such as queue assignment, as shown below: ip access-list example-1 permit ip 1.1.1.1 0.0.0.255 any assign-queue 2 permit every exit Actions specified in the “set” clauses of a route-map utilize the hardware entries of the corresponding ACL. This sharing does not consume additional hardware resources, as DNOS supports multiple actions in an ACL rule. However, if conflicting actions are specified, an error is thrown. Locally Generated Packets Policy Based Routing does not affect locally generated packets, i.e. packets generated by protocols running on the switch. Route-Map Changes Require Reapply Once a route-map has been applied to an interface (e.g., using the ip policy route-map command), changes to the ACL or route-map do not take effect on the interface until one of the following activities is completed: • The route-map is removed from the interface and reapplied. • The router is reloaded. Examples See "Policy Based Routing Examples" on page 640. 598 Configuring Access Control Lists Configuring ACLs (Web) This section provides information about the OpenManage Switch Administrator pages for configuring and monitoring ACLs on a Dell Networking N2000, N3000, and N4000 series switches. For details about the fields on a page, click at the top of the page. IP ACL Configuration Use the IP ACL Configuration page to add or remove IP-based ACLs. To display the IP ACL Configuration page, click Switching → Network Security → Access Control Lists → IP Access Control Lists → Configuration in the navigation panel. Figure 20-1. IP ACL Configuration Adding an IPv4 ACL To add an IPv4 ACL: 1 Open the IP ACL Configuration page. 2 Click Add to display the Add IP ACL page. 3 Specify an ACL name. Configuring Access Control Lists 599 Figure 20-2. Add IP ACL 4 Click Apply. Removing IPv4 ACLs To delete an IPv4 ACL: 1 From the IP ACL Name menu on the IP ACL Configuration page, select the ACL to remove. 2 Select the Remove checkbox. 3 Click Apply. Viewing IPv4 ACLs To view configured ACLs, click Show All from the IP ACL Configuration page. Figure 20-3. View IPv4 ACLs 600 Configuring Access Control Lists IP ACL Rule Configuration Use the IP ACL Rule Configuration page to define rules for IP-based ACLs. The access list definition includes rules that specify whether traffic matching the criteria is forwarded normally or discarded. Additionally, you can specify to assign traffic to a particular queue, filter on some traffic, change VLAN tag, shut down a port, and/or redirect the traffic to a particular port. NOTE: There is an implicit deny all rule at the end of an ACL list. This means that if an ACL is applied to a packet and if none of the explicit rules match, then the final implicit "deny all" rule applies and the packet is dropped. To display the IP ACL Rule Configuration page, click Switching → Network Security → Access Control Lists → IP Access Control Lists → Rule Configuration in the navigation panel. Configuring Access Control Lists 601 Figure 20-4. IP ACL - Rule Configuration Removing an IP ACL Rule To delete an IP ACL rule: 1 From the Rule ID menu, select the ID of the rule to delete. 2 Select the Remove option near the bottom of the page. 3 Click Apply to remove the selected rule. 602 Configuring Access Control Lists MAC ACL Configuration Use the MAC ACL Configuration page to define a MAC-based ACL. To display the MAC ACL Configuration page, click Switching → Network Security → Access Control Lists → MAC Access Control Lists → Configuration in the navigation panel. Figure 20-5. MAC ACL Configuration Adding a MAC ACL To add a MAC ACL: 1 Open the MAC ACL Configuration page. 2 Click Add to display the Add MAC ACL page. 3 Specify an ACL name. Figure 20-6. Add MAC ACL 4 Click Apply. Configuring Access Control Lists 603 Renaming or Removing MAC ACLs To rename or delete a MAC ACL: 1 From the MAC ACL Name menu on the MAC ACL Configuration page, select the ACL to rename or remove. 2 To rename the ACL, select the Rename checkbox and enter a new name in the associated field. 3 To remove the ACL, select the Remove checkbox. 4 Click Apply. Viewing MAC ACLs To view configured ACLs, click Show All from the MAC ACL Configuration page. 604 Configuring Access Control Lists MAC ACL Rule Configuration Use the MAC ACL Rule Configuration page to define rules for MAC-based ACLs. The access list definition includes rules that specify whether traffic matching the criteria is forwarded normally or discarded. A default deny all rule is the last rule of every list. To display the MAC ACL Rule Configuration page, click Switching → Network Security → Access Control Lists → MAC Access Control Lists → Rule Configuration in the navigation panel. Figure 20-7. MAC ACL Rule Configuration Removing a MAC ACL Rule To delete a MAC ACL rule: 1 From the Rule ID menu, select the ID of the rule to delete. 2 Select the Remove option near the bottom of the page. 3 Click Apply to remove the selected rule. Configuring Access Control Lists 605 IPv6 ACL Configuration Use the IPv6 ACL Configuration page to add or remove IP-based ACLs. To display the IP ACL Configuration page, click Switching → Network Security → Access Control Lists → IPv6 Access Control Lists → IPv6 ACL Configuration in the navigation panel. Figure 20-8. IPv6 ACL Configuration Adding an IPv6 ACL To add an IPv6 ACL: 1 Open the IPv6 ACL Configuration page. 2 Click Add to display the Add IPv6 ACL page. 3 Specify an ACL name. Figure 20-9. Add IPv6 ACL 4 Click Apply. 606 Configuring Access Control Lists Removing IPv6 ACLs To delete an IPv6 ACL: 1 From the IPv6 ACL Name menu on the IPv6 ACL Configuration page, select the ACL to remove. 2 Select the Remove checkbox. 3 Click Apply. Viewing IPv6 ACLs To view configured ACLs, click Show All from the IPv6 ACL Configuration page. The IPv6 ACL Table page displays. IPv6 ACL Rule Configuration Use the IPv6 ACL Rule Configuration page to define rules for IPv6-based ACLs. The access list definition includes rules that specify whether traffic matching the criteria is forwarded normally or discarded. Additionally, you can specify to assign traffic to a particular queue, filter on some traffic, change VLAN tag, shut down a port, and/or redirect the traffic to a particular port. By default, no specific value is in effect for any of the IPv6 ACL rules. There is an implicit deny all rule at the end of an ACL list. This means that if an ACL is applied to a packet and if none of the explicit rules match, then the final implicit deny all rule applies and the packet is dropped. To display the IPv6 ACL Rule Configuration page, click Switching → Network Security → Access Control Lists → IPv6 Access Control Lists → Rule Configuration in the navigation menu. Configuring Access Control Lists 607 Figure 20-10. IPv6 ACL - Rule Configuration Removing an IPv6 ACL Rule To delete an IPv6 ACL rule: 1 From the Rule ID menu, select the ID of the rule to delete. 2 Select the Remove option near the bottom of the page. 3 Click Apply to remove the selected rule. 608 Configuring Access Control Lists ACL Binding Configuration When an ACL is bound to an interface, all the rules that have been defined are applied to the selected interface. Use the ACL Binding Configuration page to assign ACL lists to ACL Priorities and Interfaces. From the web interface, you can configure the ACL rule in the ingress or egress direction so that the ACLs implement security rules for packets entering or exiting the port. You can apply ACLs to any physical (including 10 Gb) interface, LAG, or routing port. To display the ACL Binding Configuration page, click Switching → Network Security → Access Control Lists → Binding Configuration in the navigation panel. Figure 20-11. ACL Binding Configuration Configuring Access Control Lists 609 Time Range Entry Configuration Use the Time Range Entry Configuration page to define time ranges to associate with ACL rules. To display the Time Range Entry Configuration page, click System → Time Synchronization → Time Range Configuration in the navigation panel. The following image shows the page after at least one time range has been added. Otherwise, the page indicates that no time ranges are configured, and the time range configuration fields are not displayed. Figure 20-12. Time Range Configuration NOTE: A time-range parameter in an ACL that is referred to by a route-map statement is active only during the time range specified. When the ACL is not active (outside the time range), the route-map simply treats the ACL as a “no match”. Adding a Time Range To configure a time range: 1 From the Time Range Entry Configuration page, click Add. 2 Specify a name to identify the time range. 610 Configuring Access Control Lists Figure 20-13. Add a Time Range 3 Click Apply. 4 Click Configuration to return to the Time Range Entry Configuration page. 5 In the Time Range Name field, select the name of the time range to configure. 6 Specify an ID for the time range. You can configure up to 10 different time range entries to include in the named range. However, only one absolute time entry is allowed per time range. 7 Configure the values for the time range entry. 8 Click Apply. 9 To add additional entries to the named time range, repeat step 5 through step 8. Configuring Access Control Lists 611 Configuring ACLs (CLI) This section provides information about the commands you use to create and configure ACLs. For more information about the commands, see the Dell Networking N2000, N3000, and N4000 Series Switches CLI Reference Guide at support.dell.com/manuals. Configuring an IPv4 ACL Beginning in Privileged EXEC mode, use the following commands to create an IPv4 ACL, configure rules for the ACL, and bind the ACL to an interface. NOTE: The ip access-group command can be issued in Global Configuration mode or Interface configuration mode. If it is applied in Global Configuration mode, the ACL binding is applied to all interfaces. If it is applied in Interface Configuration mode, it is applied only to the specified interfaces within the mode. Command Purpose configure Enter global configuration mode. access-list name Create an extended ACL and enter IPv4 access-list configuration mode. 612 Configuring Access Control Lists Command Purpose {deny | permit} {every | {{ipv4-protocol | 0-255 | every} {srcip srcmask | any | host srcip} [{range {portkey | startport} {portkey | endport} | {eq | neq | lt | gt} {portkey | 0-65535} ] {dstip dstmask | any | host dstip} [{range {portkey | startport} {portkey | endport} | {eq | neq | lt | gt} {portkey | 0-65535}] [flag [+fin | -fin] [+syn | -syn] [+rst | -rst] [+psh | -psh] [+ack | ack] [+urg | -urg] [established]] [icmptype icmp-type [icmpcode icmp-code] | icmpmessage icmp-message] [igmp-type igmp-type] [fragments] [precedence precedence | tos tos [tosmask] | dscp dscp]}} [time-range time-range-name] [log] [assign-queue queue-id] [{mirror | redirect} unit/slot/port] [ratelimit rate burst-size] Enter the permit and deny conditions for the extended ACL. • {deny | permit}–Specifies whether the IP ACL rule permits or denies the matching traffic. • {ipv4-protocol | number| every }—Specifies the protocol to match for the IP ACL rule. – IPv4 protocols: eigrp, gre, icmp, igmp, ip, ipinip, ospf, tcp, udp, pim – Every: Match any protocol (don’t care) • srcip srcmask | any | host srcip—Specifies a source IP address and netmask to match for the IP ACL rule. – Specifying “any” implies specifying srcip as “0.0.0.0” and srcmask as “255.255.255.255” for IPv4. – Specifying “host A.B.C.D” implies srcip as “A.B.C.D” and srcmask as “0.0.0.0”. • [{{eq | neq | lt | gt} {portkey | number} | range startport endport}]—Specifies the layer 4 destination port match condition for the IP ACL rule. A destination port number, which ranges from 0-65535, can be entered, or a portkey, which can be one of the following keywords: domain, echo, ftp, ftp-data, http, smtp, snmp, telnet, tftp, and www. Each of these keywords translates into its equivalent destination port number. – When “range” is specified, IP ACL rule matches only if the layer 4 port number falls within the specified portrange. The startport and endport parameters identify the first and last ports that are part of the port range. They have values from 0 to 65535. The ending port must have a value equal or greater than the starting port. The starting port, ending port, and all ports in between will be part of the layer 4 port range. Configuring Access Control Lists 613 Command Purpose continued – When “eq” is specified, IP ACL rule matches only if the layer 4 port number is equal to the specified port number or portkey. – When “lt” is specified, IP ACL rule matches if the layer 4 destination port number is less than the specified port number or portkey. It is equivalent to specifying the range as 0 to . – When “gt” is specified, IP ACL rule matches if the layer 4 destination port number is greater than the specified port number or portkey. It is equivalent to specifying the range as to 65535. – When “neq” is specified, IP ACL rule matches only if the layer 4 destination port number is not equal to the specified port number or portkey. – IPv4 TCP port names: bgp, domain, echo, ftp, ftpdata, http, smtp, telnet, www, pop2, pop3 – IPv4 UDP port names: domain, echo, ntp, rip, snmp, tftp, time, who • dstip dstmask | any | host dstip—Specifies a destination IP address and netmask for match condition of the IP ACL rule. – Specifying “any” implies specifying dstip as “0.0.0.0” and dstmask as “255.255.255.255”. – Specifying “host A.B.C.D” implies dstip as “A.B.C.D” and dstmask as “0.0.0.0”. • [precedence precedence | tos tos [tosmask] | dscp dscp]—Specifies the TOS for an IP/TCP/UDP ACL rule depending on a match of precedence or DSCP values using the parameters dscp, precedence, or tos tosmask. 614 Configuring Access Control Lists Command Purpose continued • flag [+fin | -fin] [+syn | -syn] [+rst | -rst] [+psh | psh] [+ack | -ack] [+urg | -urg] [established]— Specifies that the IP/TCP/UDP ACL rule matches on the TCP flags. – Ack – Acknowledgement bit – Fin – Finished bit – Psh – push bit – Rst – reset bit – Syn – Synchronize bit – Urg – Urgent bit – When “+” is specified, a match occurs if specified flag is set in the TCP header. – When “-” is specified, a match occurs if specified flag is *NOT* set in the TCP header. – When “established” is specified, a match occurs if either the RST or ACK bits are set in the TCP header. – This option is visible only if protocol is “tcp”. • [icmp-type icmp-type [icmp-code icmp-code] | icmpmessage icmp-message] —Specifies a match condition for ICMP packets. – When icmp-type is specified, IP ACL rule matches on the specified ICMP message type, a number from 0 to 255. – When icmp-code is specified, IP ACL rule matches on the specified ICMP message code, a number from 0 to 255. – Specifying icmp-message implies both icmp-type and icmp-code are specified. – ICMP message is decoded into corresponding ICMP type and ICMP code within that ICMP type. This option is visible only if the protocol is “icmp”. – IPv4 ICMP message types: echo echo-reply hostredirect mobile-redirect net-redirect net-unreachable redirect packet-too-big port-unreachable sourcequench router-solicitation router-advertisement timeexceeded ttl-exceeded unreachable Configuring Access Control Lists 615 Command Purpose continued • igmp-type igmp-type—When igmp-type is specified, IP ACL rule matches on the specified IGMP message type (i.e., a number from 0 to 255). • fragments—Specifies the rule matches packets that are non-initial fragments (fragment bit asserted). Not valid for rules that match L4 information such as TCP port number since that information is carried in the initial packet. This keyword is visible only if the protocol is IP, TCP, or UDP. • log—Specifies that this rule is to be logged. • time-range time-range-name—Allows imposing time limitation on the ACL rule as defined by the parameter time-range-name. If a time range with the specified name does not exist and the ACL containing this ACL rule is applied to an interface or bound to a VLAN, then the ACL rule is applied immediately. If a time range with specified name exists and the ACL containing this ACL rule is applied to an interface or bound to a VLAN, then the ACL rule is applied when the time-range with specified name becomes active. The ACL rule is removed when the time-range with specified name becomes inactive. • assign-queue queue-id—Specifies the assign-queue, which is the queue identifier to which packets matching this rule are assigned. • {mirror | redirect} unit/slot/ port—Specifies the mirror or redirect interface which is the unit/slot/port to which packets matching this rule are copied or forwarded, respectively. • rate-limit rate burst-size—Specifies the allowed rate of traffic as per the configured rate in kbps, and burst-size in kbytes. – Rate – the committed rate in kilobits per second – Burst-size – the committed burst size in Kilobytes. 616 Configuring Access Control Lists Command Purpose interface interface (Optional) Enter interface configuration mode for the specified interface. The interface variable includes the interface type and number, for example tengigabitethernet 1/0/3. You can also specify a range of interfaces with the interface range command, for example, interface range tengigabitethernet 1/0/8-12 configures interfaces 8, 9, 10, 11, and 12. ip access-group name direction seqnum Bind the specified ACL to an interface. NOTE: To apply this ACL to all interfaces, issue the command in Global Configuration mode. • name — Access list name. (Range: Valid IP access-list name up to 31 characters in length) • direction — Direction of the ACL. (Range: In or out. Default is in.) • seqnum — Precedence for this interface and direction. A lower sequence number has higher precedence. Range: 1 – 4294967295. Default is1. CTRL + Z Exit to Privileged EXEC mode. show ip access-lists [name] Display all IPv4 access lists and all of the rules that are defined for the IPv4 ACL. Use the optional name parameter to identify a specific IPv4 ACL to display. Configuring Access Control Lists 617 Configuring a MAC ACL Beginning in Privileged EXEC mode, use the following commands to create an MAC ACL, configure rules for the ACL, and bind the ACL to an interface. Command Purpose configure Enter global configuration mode. mac access-list extended Create a named MAC ACL. This command also enters name MAC Access List Configuration mode. If a MAC ACL with this name already exists, this command enters the mode to update the existing ACL. {deny | permit} {srcmac srcmacmask | any} {dstmac dstmacmask | any | bpdu} [{ethertypekey | 0x0600-0xFFFF } [vlan eq 0-4093] [cos 0-7] [secondary-vlan eq 04093] [secondary-cos 07] [log] [time-range time-range-name] [assign-queue queue-id] [{mirror |redirect} interface] Specify the rules (match conditions) for the MAC access list. • srcmac — Valid source MAC address in format xxxx.xxxx.xxxx. • srcmacmask — Valid MAC address bitmask for the source MAC address in format xxxx.xxxx.xxxx. • any — Packets sent to or received from any MAC address • dstmac — Valid destination MAC address in format xxxx.xxxx.xxxx. • destmacmask — Valid MAC address bitmask for the destination MAC address in format xxxx.xxxx.xxxx. • bpdu — Bridge protocol data unit • ethertypekey — Either a keyword or valid four-digit hexadecimal number. (Range: Supported values are appletalk, arp, ibmsna, ipv4, ipv6, ipx, mplsmcast, mplsucast, Netbios, novell, pppoe, rarp.) • 0x0600-0xFFFF — Specify custom EtherType value (hexadecimal range 0x0600-0xFFFF) • vlan eq — VLAN number. (Range 0-4093) • cos — Class of service. (Range 0-7) • log — Specifies that this rule is to be logged. • time-range-name — Specifies the named time range to associate with the ACL rule. 618 Configuring Access Control Lists Command continued Purpose – When “gt” is specified, IPv6 ACL rule matches if the layer 4 destination port number is greater than the specified port number or portkey. It is equivalent to specifying the range as to 65535. – When “neq” is specified, IPv6 ACL rule matches only if the layer 4 destination port number is not equal to the specified port number or portkey. – IPv6 TCP port names: bgp, domain, echo, ftp, ftpdata, http, smtp, telnet, www, pop2, pop3 – IPv6 UDP port names: domain, echo, ntp, rip, snmp, time, who • destination-ipv6-prefix/prefix-length | any | host destination-ipv6-address—Specifies a destination IP address and netmask for match condition of the IP ACL rule. – For IPv6 ACLs, “any” implies 0::/128 prefix and a mask of all ones. – Specifying host implies prefix length as “/128” and a mask of 0::/128. • [precedence precedence | tos tos [tosmask] | dscp dscp]—Specifies the TOS for an IP/TCP/UDP ACL rule depending on a match of precedence or DSCP values using the parameters dscp, precedence, or tos tosmask. • flag [+fin | -fin] [+syn | -syn] [+rst | -rst] [+psh | psh] [+ack | -ack] [+urg | -urg] [established]—Specifies that the IP/TCP/UDP ACL rule matches on the TCP flags. – When “+” is specified, a match occurs if specified flag is set in the TCP header. – When “-” is specified, a match occurs if specified flag is *NOT* set in the TCP header. – When “established” is specified, a match occurs if specified either RST or ACK bits are set in the TCP header. Configuring Access Control Lists 619 Command Purpose continued – – – – – – – This option is visible only if the protocol is tcp. Ack – Acknowledgement bit Fin – Finished bit Psh – push bit Rst – reset bit Syn – Synchronize bit Urg – Urgent bit • [icmp-type icmp-type [icmp-code icmp-code] | icmpmessage icmp-message]—Specifies a match condition for ICMP packets. – When icmp-type is specified, IP ACL rule matches on the specified ICMP message type, a number from 0 to 255. – When icmp-code is specified, IP ACL rule matches on the specified ICMP message code, a number from 0 to 255. – Specifying icmp-message implies both icmp-type and icmp-code are specified. – ICMP message is decoded into corresponding ICMP type and ICMP code within that ICMP type. This option is visible only if the protocol is “icmpv6”. – ICMPv6 message types: destination-unreachable echoreply echo-request header hop-limit mld-query mldreduction mld-report nd-na nd-ns next-header noadmin no-route packet-too-big port-unreachable router-solicitation router-advertisement routerrenumbering time-exceeded unreachable – The icmpv6 message types are available only if the protocol is icmpv6. • fragments—Specifies the rule matches packets that are non-initial fragments (fragment bit asserted). Not valid for rules that match L4 information such as TCP port number since that information is carried in the initial packet. IPv6 fragments contain an IPv6 Fragment extension header. 620 Configuring Access Control Lists Command Purpose continued • routing—Specifies that IP ACL rule matches on routed packets. Routed packets contain an IPv6 “routing” extension header. • log—Specifies that this rule is to be logged. • time-range time-range-name—Allows imposing time limitation on the ACL rule as defined by the parameter time-range-name. If a time range with the specified name does not exist and the ACL containing this ACL rule is applied to an interface or bound to a VLAN, then the ACL rule is applied immediately. If a time range with specified name exists and the ACL containing this ACL rule is applied to an interface or bound to a VLAN, then the ACL rule is applied when the time-range with specified name becomes active. The ACL rule is removed when the time-range with specified name becomes inactive. • assign-queue queue-id—Specifies the assign-queue, which is the queue identifier to which packets matching this rule are assigned. • {mirror | redirect} unit/slot/ port—Specifies the mirror or redirect interface which is the unit/slot/port to which packets matching this rule are copied or forwarded, respectively. • rate-limit rate burst-size—Specifies the allowed rate of traffic as per the configured rate in kbps, and burst-size in kbytes. – Rate – the committed rate in kilobits per second – Burst-size – the committed burst size in Kilobytes. interface interface (Optional) Enter interface configuration mode for the specified interface. The interface variable includes the interface type and number, for example tengigabitethernet 1/0/3. You can also specify a range of interfaces with the interface range command, for example, interface range tengigabitethernet 1/0/8-12 configures interfaces 8, 9, 10, 11, and 12. Configuring Access Control Lists 621 Command Purpose mac access-group name Bind the specified MAC ACL to an interface. direction seqnum NOTE: To apply this ACL to all interfaces, issue the command in Global Configuration mode. • name — Access list name. (Range: Valid MAC access-list name up to 31 characters in length) • direction — Direction of the ACL. (Range: In or out. Default is in.) • seqnum — Precedence for this interface and direction. A lower sequence number has higher precedence. Range: 1 – 4294967295. Default is1. CTRL + Z Exit to Privileged EXEC mode. show mac access-lists [name] Display all MAC access lists and all of the rules that are defined for the MAC ACL. Use the optional name parameter to identify a specific MAC ACL to display. 622 Configuring Access Control Lists Configuring an IPv6 ACL Beginning in Privileged EXEC mode, use the following commands to create an IPv6 ACL, configure rules for the ACL, and bind the ACL to an interface. Command Purpose configure Enter global configuration mode. ipv6 traffic-filter name Create an extended IPv6 ACL. This command also enters IPv6 Access List Configuration mode. If an IPv6 ACL with this name already exists, this command enters the mode to update the existing ACL. Configuring Access Control Lists 623 Command Purpose {deny | permit} {ipv6protocol | number | every} {source-ipv6prefix/prefix-length | any | host source-ipv6address} [{range {portkey | startport} {portkey | endport} | {eq | neq | lt | gt} {portkey | 0-65535}] {destination-ipv6prefix/prefix-length | any | host destination-ipv6address} [{range {portkey | startport} {portkey | endport} | {eq | neq | lt | gt} {portkey | 0-65535}] [flag [+fin | -fin] [+syn | -syn] [+rst | -rst] [+psh | -psh] [+ack | ack] [+urg | -urg] [established]] [flowlabel value] [icmp-type icmp-type [icmp-code icmp-code] | icmpmessage icmp-message] [routing] [fragments] [dscp dscp]}} [log] [assign-queue queue-id] [{mirror | redirect} unit/slot/port] [ratelimit rate burst-size] • {deny | permit}–Specifies whether the IP ACL rule permits or denies the matching traffic. • {ipv6-protocol | number| every }—Specifies the protocol to match for the IP ACL rule. – IPv4 protocols: icmpv6, ipv6, tcp and udp – Every: Match any protocol (don’t care) 624 • source-ipv6-prefix/prefixlength | any | host src-ipv6address—Specifies a source IP address and netmask to match for the IP ACL rule. – For IPv6 ACLs, “any” implies a 0::/128 prefix and a mask of all ones. – Specifying “host X::X” implies a prefix length as “/128” and a mask of 0::/128. • [{range {portkey | startport} {portkey | endport} | {eq | neq | lt | gt} {portkey | 0-65535}]—Specifies the layer 4 destination port match condition for the IP/TCp/UDP ACL rule. A destination port number, which ranges from 0-65535, can be entered, or a portkey, which can be one of the following keywords: bgp, domain, echo, ftp, ftp-data, http, ntp, pop2, pop3, rip, smtp, snmp, telnet, tftp, telnet, time, who and www. Each of these keywords translates into its equivalent destination port number. – When “range” is specified, IPv6 ACL rule matches only if the layer 4 port number falls within the specified portrange. The startport and endport parameters identify the first and last ports that are part of the port range. They have values from 0 to 65535. The ending port must have a value equal or greater than the starting port. The starting port, ending port, and all ports in between will be part of the layer 4 port range. – When “eq” is specified, IPv6 ACL rule matches only if the layer 4 port number is equal to the specified port number or portkey. – When “lt” is specified, IPv6 ACL rule matches if the layer 4 destination port number is less than the specified port number or portkey. It is equivalent to specifying the range as 0 to . Configuring Access Control Lists Command Purpose (Continued) • destination ipv6 prefix — IPv6 prefix in IPv6 global address format. • flow label value — The value to match in the Flow Label field of the IPv6 header (Range 0–1048575). • dscp dscp — Specifies the TOS for an IPv6 ACL rule depending on a match of DSCP values using the parameter dscp. • log — Specifies that this rule is to be logged. • time-range-name — Specifies the named time range to associate with the ACL rule. • assign-queue queue-id — Specifies particular hardware queue for handling traffic that matches the rule. • mirror interface — Allows the traffic matching this rule to be copied to the specified interface. • redirect interface — This parameter allows the traffic matching this rule to be forwarded to the specified interface. interface interface (Optional) Enter interface configuration mode for the specified interface. The interface variable includes the interface type and number, for example tengigabitethernet 1/0/3. You can also specify a range of interfaces with the interface range command, for example, interface range tengigabitethernet 1/0/8-12 configures interfaces 8, 9, 10, 11, and 12. ipv6 traffic-filter name Bind the specified IPv6 ACL to an interface. direction [sequence seq- NOTE: To apply this ACL to all interfaces, issue the command num] in Global Configuration mode. • name — Access list name. (Range: Valid IPv6 access-list name up to 31 characters in length) • direction — Direction of the ACL. (Range: In or out. Default is in.) • seqnum — Precedence for this interface and direction. A lower sequence number has higher precedence. Range: 1 – 4294967295. Default is1. Configuring Access Control Lists 625 Command Purpose CTRL + Z Exit to Privileged EXEC mode. show ipv6 access-lists [name] Display all IPv6 access lists and all of the rules that are defined for the IPv6 ACL. Use the optional name parameter to identify a specific IPv6 ACL to display. Configuring a Time Range Beginning in Privileged EXEC mode, use the following commands to create a time range and configure time-based entries for the time range. Command Purpose configure Enter global configuration mode. time-range name Create a named time range and enter the Time-Range Configuration mode for the range. absolute {[start time date] [end time date ]} Configure a nonrecurring time entry for the named time range. • start time date — Time and date the ACL rule starts going into effect. The time is expressed in a 24-hour clock, in the form of hours:minutes. For example, 8:00 is 8:00 am and 20:00 is 8:00 pm. The date is expressed in the format day month year. If no start time and date are specified, the configuration statement is in effect immediately. • end time date — Time and date the ACL rule is no longer in effect. 626 Configuring Access Control Lists Command Purpose periodic {days-of-theConfigure a recurring time entry for the named time week time} to {[days-of- range. the-week ] time} • days-of-the-week —The first occurrence indicates the starting day(s) the ACL goes into effect. The second occurrence is the ending day(s) when the ACL rule is no longer in effect. If the end days-of-the-week are the same as the start, they can be omitted This variable can be any single day or combinations of days: Monday, Tuesday, Wednesday, Thursday, Friday, Saturday, Sunday. Other possible values are: – daily -- Monday through Sunday – weekdays -- Monday through Friday – weekend -- Saturday and Sunday • time — Time the ACL rule starts going into effect (first occurrence) or ends (second occurrence). The time is expressed in a 24-hour clock, in the form of hours:minutes. CTRL + Z Exit to Privileged EXEC mode. show time-range [name] View information about all configured time ranges, including the absolute/periodic time entries that are defined for each time range. Use the name variable to view information about the specified time range. Configuring Access Control Lists 627 ACL Configuration Examples This section contains the following examples: • "Basic Rules" on page 628 • "Internal System ACLs" on page 629 • "Complete ACL Example" on page 629 • "Advanced Examples" on page 633 • "Policy Based Routing Examples" on page 640 NOTE: None of these ACL rules are applicable to the OOB interface. Basic Rules • Inbound rule allowing all packets: permit every Administrators should be cautious when using the permit every rule in an access list, especially when using multiple access lists. All packets match a permit every rule and no further processing is done on the packet. This means that a permit every match in an access list will skip processing subsequent rules in the current or subsequent access-lists and allow all packets not previously denied by a prior rule. • Inbound rule to drop all packets: As the last rule in a list, this rule is redundant as an implicit "deny every" is added after the end of the last access-group configured on an interface. deny every Administrators should be cautious when using the deny every rule in an access list, especially when using multiple access lists. When a packet matches a rule, no further processing is done on the packet. This means that a deny every match in an access list will skip processing subsequent rules in the current or subsequent access-lists and drop all packets not previously allowed by a prior rule. • 628 Inbound rule allowing access FROM hosts with IP addresses ranging from 10.0.46.0 to 10.0.47.254: Configuring Access Control Lists permit ip 10.0.46.0 0.0.1.255 any • Inbound rule allowing access TO hosts with IP addresses ranging from 10.0.48.0 to 10.0.49.254: permit ip any 10.0.48.0 0.0.1.255 As the last rule in an administrator-defined list, the narrower scope of this inbound rule has no effect other than to possibly interfere with switch operations. The system installs an implicit deny every rule after the end of the last access group bound to an interface: deny ip any any Internal System ACLs The switch installs a number of internal ACLS to trap packets to the CPU for processing. Examples of these types of packets are spanning tree BPDUs, IEEE 802.1x EAPOL packets, iSCSI packets, IP source guard packets, LLPF packets, LLDP packets, IEEE 802.1AD packets, etc. These internal ACLs are generally configured at the lowest priority (higher numerically) so that the switch administrator, through the use of ACLs, can override the default switch behavior. Some of the system rules are installed when the administrator enables specific protocols; other rules are always present and may have their behaviors altered by enabling or disabling protocols. For example, spanning tree BPDUs, LLDP packets, and IEEE 802.1X packets are never forwarded by the switch. Complete ACL Example The following example is a complete inbound ACL that allows access for hosts connected to gi1/0/1 with IP address in 10.1.1.x range to send IP packets to 192.168.0.X hosts on gi1/0/2. IP packets not from 10.1.1.x addresses or not addressed to 192.168.0.x hosts are dropped. Packets with protocols other than IP, DNS, ARP, or ICMP are dropped. Allowing ICMP supports the 10.1.1.x hosts in reliably receiving and initiating TCP connections and pinging through the switch. This example also allows ARP and DNS packets to any destination and is suitable for an L2 switch. mac access-list extended Allow-ARP permit any any arp exit Configuring Access Control Lists 629 ip access-list Allow-10-1-1-x permit ip 10.1.1.0 0.0.0.255 192.168.0.0 0.0.0.255 permit icmp 10.1.1.0 0.0.0.255 any permit ip 0.0.0.0 255.255.255.255 any permit udp any any eq domain exit interface gi1/0/1 mac access-group Allow-ARP in 10 ip access-group Allow-10-1-1-x in 20 exit Another list on the 192.168.0.x network attached port (gi1/0/2) is configured for this example. Because the two access lists are complementary/end-to-end, it is necessary to allow ICMP packets to travel between the attached hosts. ip access-list Allow-192-168-0-x permit ip 192.168.0.0 0.0.0.255 10.1.1.0 0.0.0.255 permit icmp 192.168.0.0 0.0.0.255 any permit udp any any eq domain exit interface gi1/0/2 mac access-group Allow-ARP in 10 ip access-group Allow-192-168-0-x in 20 exit Consider the following inbound rules that allow Telnet connections and UDP traffic from the 192.168.0.x network to host 10.1.1.23: ip access-list Host10-1-1-23 ! Permit Telnet traffic from 192.168.0.X network to host 10.1.1.23 permit tcp 192.168.0.0 0.0.0.255 host 10.1.1.23 eq telnet ! Permit TCP traffic from 192.168.0.X network to host 10.1.1.23 permit tcp 192.168.0.0 0.0.0.255 host 10.1.1.23 ! Permit UDP traffic from 192.168.0.X network to host 10.1.1.23 permit udp 192.168.0.0 0.0.0.255 host 10.1.1.23 ! Permit IP traffic from 192.168.0.X network to 10.1.1.x network permit ip 192.168.0.0 0.0.0.255 10.1.1.23 0.0.0.255 In the above list, the fourth rule allows all IP packets between the network and host. The narrower scope of the first three rules is redundant, as all IP traffic, including TCP and UDP, is permitted by the fourth rule. The 630 Configuring Access Control Lists following list has corrected rules that allow Telnet and UDP packets only and rely on the implicit "deny all" after the end of the last access group to deny other traffic. ip access-list Host10-1-1-23 ! Permit Telnet traffic from 192.168.0.X network to host 10.1.1.23 permit tcp 192.168.0.0 0.0.0.255 host 10.1.1.23 eq telnet ! Permit UDP traffic from 192.168.0.X network to host 10.1.1.23 permit udp 192.168.0.0 0.0.0.255 host 10.1.1.23 ACLs support TCP and UDP port matching using operators: ip access-list Host10-1-1-23 ! Permit Telnet traffic from 192.168.0.X network to host 10.1.1.23 permit tcp 192.168.0.0 0.0.0.255 host 10.1.1.23 eq telnet ! Permit UDP traffic from 192.168.0.X network to host 10.1.1.23 permit udp 192.168.0.0 0.0.0.255 host 10.1.1.23 ip access-list Host10-1-1-23 ! Permit Telnet traffic from 192.168.0.X network to host 10.1.1.23 permit tcp 192.168.0.0 0.0.0.255 host 10.1.1.23 eq telnet ! Permit UDP traffic from 192.168.0.X network to host 10.1.1.23 permit udp 192.168.0.0 0.0.0.255 host 10.1.1.23 The range operator is inclusive of the specified port parameters. ACLs support TCP flags. If multiple flags are set (+flag) in a single rule, only packets with the all the same flags asserted are matched (logical AND). Likewise, if multiple flags are cleared (–flag) in a single rule, only packets with the same flags cleared are matched. The established keyword matches TCP packets with either the RST or ACK bits set (logical OR). Flags that are neither set nor cleared in the rule are not checked in the ACL (don't care or wildcard). ip access-list Host10-1-1-23 ! Permit Telnet traffic from 192.168.0.X network to host 10.1.1.23 permit tcp 192.168.0.0 0.0.0.255 host 10.1.1.23 eq telnet ! Permit UDP traffic from 192.168.0.X network to host 10.1.1.23 permit udp 192.168.0.0 0.0.0.255 host 10.1.1.23 The following is an example rule to match TCP packets with the PUSH flag asserted AND the RESET flag cleared. The other flags bits are "don't care": ip access-list Host10-1-1-23 Configuring Access Control Lists 631 ! Permit Telnet traffic from 192.168.0.X network to host 10.1.1.23 permit tcp 192.168.0.0 0.0.0.255 host 10.1.1.23 eq telnet ! Permit UDP traffic from 192.168.0.X network to host 10.1.1.23 permit udp 192.168.0.0 0.0.0.255 host 10.1.1.23 ACLs may also contain a number of shorthand qualifiers for protocols and IP, TCP, and UDP port numbers, as shown below. Note that not all of these qualifiers make sense in the context of any given port number; e.g., ftp and ftp-data only make sense in the context of the IP or UDP protocols, while an HTTP port number only makes sense in terms of the TCP or IP protocols. Refer to RFC 1700 or iana.org/protocols for a list of protocol numbers. ip access-list Host10-1-1-23 ! Permit Telnet traffic from 192.168.0.X network to host 10.1.1.23 permit tcp 192.168.0.0 0.0.0.255 host 10.1.1.23 eq telnet ! Permit UDP traffic from 192.168.0.X network to host 10.1.1.23 permit udp 192.168.0.0 0.0.0.255 host 10.1.1.23 ip access-list Host10-1-1-23 ! Permit Telnet traffic from 192.168.0.X network to host 10.1.1.23 permit tcp 192.168.0.0 0.0.0.255 host 10.1.1.23 eq telnet ! Permit UDP traffic from 192.168.0.X network to host 10.1.1.23 permit udp 192.168.0.0 0.0.0.255 host 10.1.1.23 ip access-list Host10-1-1-23 ! Permit Telnet traffic from 192.168.0.X network to host 10.1.1.23 permit tcp 192.168.0.0 0.0.0.255 host 10.1.1.23 eq telnet ! Permit UDP traffic from 192.168.0.X network to host 10.1.1.23 permit udp 192.168.0.0 0.0.0.255 host 10.1.1.23 To bind an access-list to an interface, use the access-group command. The in parameter specifies that the ACL is applied to ingress packets. The out parameter specifies that the ACL is applied to egress packets not generated by the switch/router. If no in/out parameter is specified, the access list default is to apply the ACL to ingress packets. ip access-list Host10-1-1-23 ! Permit Telnet traffic from 192.168.0.X network to host 10.1.1.23 permit tcp 192.168.0.0 0.0.0.255 host 10.1.1.23 eq telnet ! Permit UDP traffic from 192.168.0.X network to host 10.1.1.23 permit udp 192.168.0.0 0.0.0.255 host 10.1.1.23 632 Configuring Access Control Lists Multiple access lists can be configured on an interface. The processing order is determined by the last parameter on the access-group command where the lowest sequence number is processed first, followed by the next higher sequence number, etc. In this example, access list Host10-1-1-21 is processed first, followed by Host1-1-23: ip access-list Host10-1-1-23 ! Permit Telnet traffic from 192.168.0.X network to host 10.1.1.23 permit tcp 192.168.0.0 0.0.0.255 host 10.1.1.23 eq telnet ! Permit UDP traffic from 192.168.0.X network to host 10.1.1.23 permit udp 192.168.0.0 0.0.0.255 host 10.1.1.23 Advanced Examples Configuring a Time-Based ACL The following example configures an ACL that denies HTTP traffic from 8:00 pm to 12:00 pm and 1:00 pm to 6:00 pm on weekdays and from 8:30 am to 12:30 pm on weekends. The ACL affects all hosts connected to ports that are members of VLAN 100. The ACL permits VLAN 100 members to browse the Internet only during lunch and after hours. To configure the switch: 1 Create a time range called work-hours. console#config console(config)#time-range work-hours 2 Configure an entry for the time range that applies to the morning shift Monday through Friday. console(config-time-range)#periodic weekdays 8:00 to 12:00 3 Configure an entry for the time range that applies to the afternoon shift Monday through Friday. console(config-time-range)#periodic weekdays 13:00 to 18:00 4 Configure an entry for the time range that applies to Saturday and Sunday. console(config-time-range)#periodic weekend 8:30 to 12:30 console(config-time-range)#exit Configuring Access Control Lists 633 5 Create an ACL named web-limit that denies HTTP traffic during the work-hours time range. console(config)#ip access-list web-limit console(config-ip-acl)#deny tcp any any eq http time-range work-hours console(config-ip-acl)#permit every 6 Enter interface configuration mode for VLAN 100 and apply the ACL to ingress traffic. console(config)#interface vlan 100 console(config-if-vlan100)#ip access-group weblimit in console(config-if-vlan100)#exit console(config)#exit 7 Verify the configuration. console(config)#show ip access-lists web-limit IP ACL Name: web-limit Rule Number: 1 Action......................................... Match All...................................... Protocol....................................... Source IP Address.............................. Destination IP Address......................... Destination Layer 4 Operator................... Destination L4 Port Keyword.................... deny FALSE 6(tcp) any any Equal To 80(www/http) Rule Number: 2 Action......................................... permit Match All...................................... TRUE Denying FTP Traffic This example drops incoming FTP setup and data traffic on interfaces gi1/0/24 to 48. This example is suitable for configuration on a switch or a router: ip access-list deny-ftp ! deny tcp any any eq ftp deny tcp any any eq ftp-data permit every exit 634 Configuring Access Control Lists interface range gi1/0/24-48 ip access-list deny-ftp in exit Allow FTP Traffic Only to an FTP Server This ACL limits traffic from a router to a directly connected FTP server (172.16.0.5) on gi1/0/11. Notice that this is an “out” ACL. Traffic to the router from the FTP server is not affected by this rule. Traffic from the router to the FTP server is limited to ICMP and packets destined to the FTP ports. There is no need to add permit rules for all the protocols the router can send to the host (e.g., ARP, ICMP, LLDP, etc.), as internally generated packets are not limited by ACLs. Routing must be enabled to process ARPs or they must be allowed by an explicit rule. We allow ICMP from remote hosts so that the FTP server can receive ICMP feedback from clients utilizing the FTP service. A better implementation would narrow the scope of the ICMP to eliminate ICMP messages not required for the FTP service, e.g., echo, echo-reply, redirect, timestamp, etc. ip access-list allow-ftp-server permit tcp any host 172.16.0.5 eq ftp-data flag established permit tcp any host 172.16.0.5 eq ftp permit icmp any any exit interface gi1/0/11 ip access-group allow-ftp-server out exit Block Incoming Pings ip access-list no-ping deny icmp any any icmp-message echo permit every exit interface gi1/0/1 ip access-group no-ping in exit Block Incoming Pings and Responses This example configures an ACL that blocks incoming pings and ping responses. Since packets generated by the CPU are not affected by ACLs, to block pinging from the switch we add a rule to block the ping responses. Configuring Access Control Lists 635 ip access-list no-ping deny icmp any any icmp-message echo deny icmp any any icmp-message echo-reply permit every exit interface gi1/0/1 ip access-group no-ping in exit Block RFC 1918 Addresses This ACL may be useful on connections to ISPs to block traffic from nonroutable addresses. ip access-list no-private-internet deny ip 10.0.0.0. 0.255.255.255 any deny ip 192.168.0.0 0.0.255.255 any deny ip 172.16.0.0 0.15.255.255 any permit every exit interface port-channel 1 access-group no-private-internet in exit Assign Packets to a CoS Queue Assign a range of source or destination TCP ports to CoS queue 3 to provide elevated service. Two rules are necessary to handle packets that have source or destination ports outside the range. ip access-list elevated-cos permit tcp any range 49152 65535 any assign-queue 3 permit tcp any any range 49152 65535 assign-queue 3 permit every exit ip access-group elevated-cos in 25 Schedule Forwarding of Packets to a Different Port This ACL L2 forwards matching packets to a different port based on a time schedule. This is not equivalent to Policy-Based Forwarding, as the TTL in the packet is not decremented, nor is a new destination MAC address written into the packet. time-range work-hours 636 Configuring Access Control Lists periodic weekdays 07:30 to 18:00 exit ip access-list redirect-traffic permit ip any 172.16.1.0 255.255.255.0 redirect te1/0/1 time-range work-hours permit every exit ip access-group redirect-traffic in 30 Rate Limit WWW Traffic (Diffserv) This ACL creates a Diffserv policy to rate-limit WWW packets. Limit and burst values require tuning for local traffic patterns and link speeds. Compare this to the next example. class-map match-all rate-limit-control ipv4 match protocol tcp match srcl4port www exit policy-map rate-limit-policy in class rate-limit-control police-simple 9216 128 conform-action transmit violate-action drop exit exit interface te1/0/1 service-policy in rate-limit-policy exit Rate limit WWW traffic (ACL) This example creates an ACL to rate-limit WWW traffic ingressing the switch on te1/0/1. Initial and established values require tuning for local traffic patterns and link speeds. Note that this ACL applies to traffic sent to the switch IP address as well as traffic forwarded by the switch (in rule). Permit rules with a rate-limit parameter do not require a following deny rule as matching packets exceeding the rate limit are discarded. Compare this with the example above. ip access-list rate-limit-www permit tcp any any eq www flag established rate-limit 9216 128 permit tcp any any eq www rate-limit 1024 64 permit every exit Configuring Access Control Lists 637 interface te1/0/1 ip access-group rate-limit-www in exit Rate Limit In-Band Management Traffic The following is an example of rate limiting in-band management traffic on an L2 switch. The first two rules rate limit Telnet and SSH (22) traffic for established connections. The third and fourth rules set specific limits for inbound Telnet and SSH connection requests (third and fourth rules). Setting the control plane mode on the access group limits the requests to those packets transferred to the CPU and does not affect packets transiting the switching silicon. Likewise, because this is internally an egress ACL, it rate limits packets egressing the silicon to the CPU and does not affect packets that are routed in software due to L3 table lookup failures, nor does it affect packets sent to the CPU via the system rules, as they are applied on ingress. The established connection rate limit parameters are 1024 Kbits/second and a burst of 128 Kbytes. The non-established rate limits are 12 Kbytes/second with a 2 Kbyte burst. ip access-list rate-limit-inband-mgmt permit tcp any any eq telnet flag established rate-limit 1024 128 permit tcp any any eq 22 flag established rate-limit 1024 128 permit tcp any any eq telnet rate-limit 12 2 permit tcp any any eq 22 rate-limit 12 2 permit every exit ip access-group rate-limit-inband-mgmt control-plane ! ! Block fragmented traffic from being sent to the CPU. ! ip access-list no-frag-inband-mgmt deny tcp any any fragments deny udp any any fragments deny ip any any fragments permit every exit ip access-group no-frag-inband-mgmt control-plane 638 Configuring Access Control Lists A Consolidated DoS Example This example includes some ACL rules to consider to reduce DoS attacks on the switch. It does not represent a complete DoS suite. A firewall with deep packet inspection capabilities should be used for true DoS protection. NOTE: The rate limits below should be adjusted to match the expected rates of traffic coming to the CPU. ip access-list reduce-dos-attacks ! ! Rate limit echo requests ! permit icmp any any icmp-message echo rate-limit 32 64 ! ! Deny telnet and rate-limit SSH to the CPU ! deny tcp any any eq telnet flag established permit tcp any any eq 22 flag established rate-limit 1024 128 deny tcp any any eq telnet permit tcp any any eq 22 rate-limit 12 2 ! ! Rate limit TCP opens ! permit tcp any any flag +syn rate-limit 8 2 ! ! Rate limit TCP closes ! permit tcp any any flag +fin rate-limit 8 2 ! ! Block TCP/UDP/IP frag attacks ! deny ip any any fragments ! ! Limit SNMP (should set source address to management stations) ! Must be tuned for SNMP walks. May need to adjust the SNMP client ! retry count or timeout. ! permit udp any any eq snmp rate-limit 1024 128 ! ! Allow other traffic types to come to CPU ! permit every exit ip access-group reduce-dos-attacks control-plane ! Configuring Access Control Lists 639 ! Further limit inbound traffic on in-band management ports. ! Allow only VLAN 99 SSH and TFTP, no telnet, HTTP, HTTPS, or SNMP. ! The management access list actions are performed by the switch ! firmware in addition to the access list actions performed by ! the switching silicon, e.g. reduce-dos-attacks. Note that ! the switch forces TFTP accesses to use the well-known TFTP port ! number 69. ! management access-list mgmt-blocks permit vlan 99 service ssh permit vlan 99 service tftp deny vlan 99 permit service any exit ! Create an in-band Management VLAN (99), assign it to two ports (gi1/0/47 ! and gi1/0/48), and add both ACLs and Management ACLs to ALL ports ! in global config mode. vlan 99 exit interface vlan 99 ip address dhcp exit interface gi1/0/47-48 switchport access vlan 99 exit management access-class mgmt-blocks line ssh login authentication default exit crypto key generate rsa crypto key generate dsa ip ssh server Policy Based Routing Examples ACL That Matches All IP Packets ip access-list match-all permit ip any any exit 640 Configuring Access Control Lists Route-Map with Scheduled Redirection of RFC 1918 Addresses to a Different NextHop time-range work-hours periodic weekdays 07:30 to 18:00 exit ip access-list subnet-172-16 permit ip any 172.16.0.0 0.15.255.255 time-range work-hours exit ip access-list subnet-192-168 permit ip any 192.168.0.0 0.0.255.255 time-range work-hours exit ip access-list subnet-10-0 permit ip any 10.0.0.0 0.255.255.255 time-range work-hours exit route-map redirect-vlan12 permit 32 match ip address subnet-172-16 subnet-192-168 subnet-10-0 set ip next-hop 12.1.13.1 set ip next-hop 12.1.14.1 exit Complete Example of Policy Based Routing on VLAN Routing Interfaces In this example, an L3 router with four VLAN routing interfaces (VLAN 10, VLAN 20, VLAN 30 and VLAN 40) is configured. Each of these interfaces is connected to L2 switches. Traffic sent to host 2.2.2.2 from host 1.1.1.2 on VLAN interface 10 is normally routed over VLAN interface 20. The steps to override the normal routing decision and policy route traffic from VLAN interface 10 to VLAN interface 30 are described following the figure. Configuring Access Control Lists 641 Figure 20-14. Policy Based Routing on VLAN Interfaces Example Layer 3 Switch L2 Switch VLAN 10 Physical Port 1/0/2 VLAN Interface 10 1.1.1.1/24 Physical Port 1/0/4 VLAN Interface 20 2.2.2.1/24 Physical Port 1/0/24 VLAN Interface 40 4.4.4.3/24 Physical Port 1/0/22 L2 Switch VLAN Interface 30 3.3.3.1/24 L2 Switch VLAN 20 VLAN 40 L2 Switch VLAN 30 Create VLANs 10, 20, 30 and 40 vlan 10,20,30,40 exit Add VLAN Membership to Physical Ports Also, configure the native VLAN on the corresponding interfaces: interface gi1/0/2 switchport mode trunk switchport trunk allowed vlan remove 1 switchport trunk native vlan 10 exit interface gi 1/0/4 switchport mode trunk swithport trunk allowed vlan remove 1 switchport trunk native vlan 20 exit interface gi1/0/22 switchport mode trunk switch trunk allowed vlan remove 1 switch trunk native vlan 30 exit 642 Configuring Access Control Lists interface gi 1/0/24 switchport mode trunk switchport trunk native vlan 40 switchport trunk allowed vlan remove 1 Enable Routing on Each VLAN Interface interface vlan 10 ip address 1.1.1.1 exit interface vlan 20 ip address 2.2.2.1 exit interface vlan 30 ip address 3.3.3.1 exit interface vlan 40 ip address 4.4.4.3 exit 255.255.255.0 255.255.255.0 255.255.255.0 255.255.255.0 Enable IP Routing (Global Configuration) ip routing In this configuration, traffic from host 1.1.1.2 to host 2.2.2.2 is routed from VLAN routing interface 10 to VLAN routing interface 20 using the directly connected subnets as they appear in the routing table. Configure Policy Routing To policy-route such traffic to VLAN routing interface 30, the following additional steps should be performed: 1 Create an access-list matching all incoming IP traffic from host 1.1.1.1 destined to host 2.2.2.2: ip access-list Match-ip-1_1_1_2-to-2_2_2_2 permit ip host 1.1.1.2 host 2.2.2.2 exit There is no need to add a ’permit every’ rule, as would be configured in a normal access list, as this ACL will only be used for PBR. The default for Configuring Access Control Lists 643 PBR is to route non-matching traffic or traffic which is addressed to a nonconnected interface normally. 2 Create a route-map and add match/set rules to the route-map: route-map Redirect_to_3_3_3_3 permit 100 match ip address Match-ip-1_1_1_2-to-2_2_2_2 set ip next-hop 3.3.3.3 exit 3 Assign the route-map to VLAN routing interface 10: interface vlan 10 ip policy route-map Redirect_to_3_3_3_3 exit Traffic matching ACL Match-ip-1_1_1_2-to-2_2_2_2 is now policy-routed to VLAN interface 30 when an interface in VLAN 30 is connected via policy Redirect_to_3_3_3_3. Counters are incremented in the “show route-map” command indicating that traffic is being policy routed. console(config)#show route-map Redirect_to_3_3_3_3 route-map "Redirect_to_3_3_3_3" permit 10 Match clauses: ip address (access-lists) : match-subnet-1_1_1_X Set clauses: ip next-hop 3.3.3.3 Policy routing matches: 19922869 packets, 1275063872 bytes 644 Configuring Access Control Lists Configuring VLANs 21 This chapter describes how to configure VLANs, including port-based VLANs, protocol-based VLANs, double-tagged VLANs, subnet-based VLANs, and Voice VLANs. The topics covered in this chapter include: • VLAN Overview • Default VLAN Behavior • Configuring VLANs (Web) • Configuring VLANs (CLI) • VLAN Configuration Examples VLAN Overview By default, all switchports on a Dell Networking N2000, N3000, and N4000 series switches are in the same broadcast domain. This means when one host connected to the switch broadcasts traffic, every device connected to the switch receives that broadcast. All ports in a broadcast domain also forward multicast and unknown unicast traffic to the connected host. Large broadcast domains can result in network congestion, and end users might complain that the network is slow. In addition to latency, large broadcast domains are a greater security risk since all hosts receive all broadcasts. Virtual Local Area Networks (VLANs) allow you to divide a broadcast domain into smaller, logical networks. Like a bridge, a VLAN switch forwards traffic based on the Layer 2 header, which is fast, and like a router, it partitions the network into logical segments, which provides better administration, security, and management of multicast traffic. Network administrators have many reasons for creating logical divisions, such as department or project membership. Because VLANs enable logical groupings, members do not need to be physically connected to the same switch or network segment. Some network administrators use VLANs to segregate traffic by type so that the time-sensitive traffic, like voice traffic, has Configuring VLANs 645 priority over other traffic, such as data. Administrators also use VLANs to protect network resources. Traffic sent by authenticated clients might be assigned to one VLAN, while traffic sent from unauthenticated clients might be assigned to a different VLAN that allows limited network access. When one host in a VLAN sends a broadcast, the switch forwards traffic only to other members of that VLAN. For traffic to go from a host in one VLAN to a host in a different VLAN, the traffic must be forwarded by a layer 3 device, such as a router. VLANs work across multiple switches and switch stacks, so there is no requirement for the hosts to be located near each other to participate in the same VLAN. NOTE: Dell Networking series switches support VLAN routing. When you configure VLAN routing, the switch acts as a layer 3 device and can forward traffic between VLANs. For more information, see "What Are VLAN Routing Interfaces?" on page 1021. Each VLAN has a unique number, called the VLAN ID. The Dell Networking series switches support a configurable VLAN ID range of 1–4093. A VLAN with VLAN ID 1 is configured on the switch by default. VLAN 1 is named default, which cannot be changed. However, you can associate names with any other VLANs that you create. In a tagged frame, the VLAN is identified by the VLAN ID in the tag. In an untagged frame, the VLAN identifier is the Port VLAN ID (PVID) specified for the port that received the frame. For information about tagged and untagged frames, see "VLAN Tagging" on page 649. The Dell Networking series switches support adding individual ports and Link Aggregation Groups (LAGs) as VLAN members. Figure 21-1 shows an example of a network with three VLANs that are department-based. The file server and end stations for the department are all members of the same VLAN. 646 Configuring VLANs Figure 21-1. Simple VLAN Topology Router Engineering VLAN 100 Switch Payroll VLAN 300 Tech Pubs VLAN 200 In this example, each port is manually configured so that the end station attached to the port is a member of the VLAN configured for the port. The VLAN membership for this network is port-based or static. Dell Networking series switches also support VLAN assignment based on any of the following criteria: • MAC address of the end station • IP subnet of the end station • Protocol of the packet transmitted by the end station Configuring VLANs 647 Table 21-1 provides an overview of the types of VLANs you can use to logically divide the network. Table 21-1. VLAN Assignment VLAN Assignment Description Port-based (Static) This is the most common way to assign hosts to VLANs. The port where the traffic enters the switch determines the VLAN membership. IP Subnet Hosts are assigned to a VLAN based on their IP address. All hosts in the same subnet are members of the same VLAN. MAC-Based The MAC address of the device determines the VLAN assignment. This type of VLAN is useful when a host might not always connect to the network through the same port but needs to be on the same VLAN. Protocol Protocol-based VLANs were developed to separate traffic based on the protocol type before IP traffic became the de facto standard in the LAN. Use a protocol-based VLAN on networks where you might have a group of hosts that use IPX or another legacy protocol. With protocol-based VLANs, you can segregate traffic based on the EtherType value in the frame. Switchport Modes You can configure each port on a Dell Networking N2000, N3000, and N4000 series switches to be in one of the following modes: 648 • Access — Access ports are intended to connect end-stations to the system, especially when the end-stations are incapable of generating VLAN tags. Access ports support a single VLAN (the PVID). Packets received untagged are processed as if they are tagged with the access port PVID. Packets received that are tagged with the PVID are also processed. Packets received that are tagged with a VLAN other than the PVID are dropped. If the VLAN associated with an access port is deleted, the PVID of the access port is set to VLAN 1. VLAN 1 may not be deleted. • Trunk — Trunk-mode ports are intended for switch-to-switch links. Trunk ports can receive both tagged and untagged packets. Tagged packets received on a trunk port are forwarded on the VLAN contained in the tag if the trunk port is a member of the VLAN. Untagged packets received on a Configuring VLANs trunk port are forwarded on the native VLAN. Packets received on another interface belonging to the native VLAN are transmitted untagged on a trunk port. • General — General ports can act like access or trunk ports or a hybrid of both. VLAN membership rules that apply to a port are based on the switchport mode configured for the port. Table 21-2 shows the behavior of the three switchport modes. Table 21-2. Switchport Mode Behavior Mode VLAN Membership Frames Accepted Frames Sent Ingress Filtering Access One VLAN Untagged/ Tagged Untagged Always On Trunk All VLANs that exist in Untagged/ the system (default) Tagged Tagged and Untagged Always On General As many as desired Tagged or Untagged On or Off Tagged or Untagged When a port is in General mode, all VLAN features are configurable. When ingress filtering is on, the frame is dropped if the port is not a member of the VLAN identified by the VLAN ID in the tag. If ingress filtering is off, all tagged frames are forwarded. The port decides whether to forward or drop the frame when the port receives the frame. VLAN Tagging Dell Networking series switches support IEEE 802.1Q tagging. Ethernet frames on a tagged VLAN have a 4-byte VLAN tag in the header. VLAN tagging is required when a VLAN spans multiple switches, which is why trunk ports transmit and receive only tagged frames. NOTE: A stack of switches behaves as a single switch, so VLAN tagging is not required for packets traversing different stack members. Configuring VLANs 649 Tagging may be required when a single port supports multiple devices that are members of different VLANs. For example, a single port might be connected to an IP phone, a PC, and a printer (the PC and printer are connected via ports on the IP phone). IP phones are typically configured to use a tagged VLAN for voice traffic, while the PC and printers typically use the untagged VLAN. Trunk ports can receive tagged and untagged traffic. Untagged traffic is tagged internally with the native VLAN. Native VLAN traffic received untagged is transmitted untagged on a trunk port. By default, trunk ports are members of all existing VLANs and will automatically participate in any newly created VLANs. The administrator can restrict the VLAN membership of a trunk port. VLAN membership for tagged frames received on a trunk port is configured separately from the membership of the native VLAN. To configure a trunk port to accept frames only for a single VLAN, both the native VLAN and the tagged VLAN membership settings must be configured. If the native VLAN for a trunk port is deleted, the trunk port drops untagged packets. Access ports accept untagged traffic and traffic tagged with the access port PVID. Untagged ingress traffic is considered to belong to the VLAN identified by the PVID. If the PVID for an access port is deleted, the PVID is set to VLAN 1. GVRP The GARP VLAN Registration Protocol (GVRP) helps to dynamically manage VLAN memberships on trunk ports. When GARP is enabled, switches can dynamically register (and de-register) VLAN membership information with other switches attached to the same segment. Information about the active VLANs is propagated across all networking switches in the bridged LAN that support GVRP. You can configure ports to forbid dynamic VLAN assignment through GVRP. The operation of GVRP relies upon the services provided by the Generic Attribute Registration Protocol (GARP). GVRP can create up to 1024 VLANs. For information about GARP timers, see "What Are GARP and GMRP?" on page 810. 650 Configuring VLANs Double-VLAN Tagging For trunk ports, which are ports that connect one switch to another switch, the Dell Networking series switches support double-VLAN tagging. This feature allows service providers to create Virtual Metropolitan Area Networks (VMANs). With double-VLAN tagging, service providers can pass VLAN traffic from one customer domain to another through a metro core in a simple and cost-effective manner. By using an additional tag on the traffic, the switch can differentiate between customers in the MAN while preserving an individual customer’s VLAN identification when the traffic enters the customer’s 802.1Q domain. With the introduction of this second tag, customers are no longer required to divide the 4-byte VLAN ID space to send traffic on a Ethernet-based MAN. In short, every frame that is transmitted from an interface has a double-VLAN tag attached, while every packet that is received from an interface has a tag removed (if one or more tags are present). In Figure 21-2, two customers share the same metro core. The service provider assigns each customer a unique ID so that the provider can distinguish between the two customers and apply different rules to each. When the configurable EtherType is assigned to something different than the 802.1Q (0x8100) EtherType, it allows the traffic to have added security from misconfiguration while exiting the metro core. For example, if the edge device on the other side of the metro core is not stripping the second tag, the packet would never be classified as a 802.1Q tag, so the packet would be dropped rather than forwarded in the incorrect VLAN. Configuring VLANs 651 Figure 21-2. Double VLAN Tagging Network Example Voice VLAN The Voice VLAN feature enables switch ports to carry voice traffic with defined priority. When multiple devices, such as a PC and an IP phone, are connected to the same port, you can configure the port to use one VLAN for voice traffic and another VLAN for data traffic. Voice over IP (VoIP) traffic is inherently time-sensitive: for a network to provide acceptable service, the transmission rate is vital. The priority level enables the separation of voice and data traffic coming onto the port. A primary benefit of using Voice VLAN is to ensure that the sound quality of an IP phone is safeguarded from deteriorating when the data traffic on the port is high. The switch uses the source MAC address of the traffic traveling through the port to identify the IP phone data flow. The Voice VLAN feature can be enabled on a per-port basis. This feature supports a configurable voice VLAN DSCP value. This value is later retrieved by LLDP when the LLDPDU is transmitted, if LLDP has been enabled on the port and the required TLV is configured for the port. 652 Configuring VLANs Identifying Voice Traffic Some VoIP phones contain full support for IEEE 802.1X. When these phones are connected to a port that uses 802.1X port-based authentication, these phones authenticate and receive their VLAN information from LLDP-MED. However, if a VoIP phone has limited support for 802.1X authentication it might try to authenticate and fail. A phone with no 802.1X support would not attempt to authenticate at all. Instead of placing these phones on an unauthenticated or guest VLAN, the switch can automatically direct the VoIP traffic to the Voice VLAN without manual configuration. The switch identifies the device as a VoIP phone by one of the following protocols: • Cisco Discovery Protocol (CDP) or Industry Standard Discovery Protocol (ISDP) for Cisco VoIP phones • DHCP vendor-specific options for Avaya VoIP phones • LLDP-MED for most VoIP phones NOTE: By default, ISDP is enabled globally and per-interface on the switch. LLDP-MED is disabled on each interface by default. Port-based authentication using 802.1X is also disabled on each port by default. After the VoIP phone receives its VLAN information, all traffic is tagged with the VLAN ID of the Voice VLAN. The phone is considered to be authorized to send traffic but not necessarily authenticated. Segregating Traffic with the Voice VLAN You can configure the switch to support Voice VLAN on a port that is connecting the VoIP phone. Both of the following methods segregate the voice traffic and the data traffic in order to provide better service to the voice traffic. • When a VLAN is associated with the Voice VLAN port, then the VLAN ID information is passed onto the VoIP phone using either the LLDP-MED or the CPD mechanism, depending on how the phone is identified: if it is identified via CDP, then the VLAN assignment is via CDP and if it is identified via LLDP-MED, then the VLAN assignment is via LLDP-MED. By this method, the voice data coming from the VoIP phone is tagged with the exchanged VLAN ID. Untagged data arriving on the switch is given the Configuring VLANs 653 default PVID of the port, and the voice traffic is received tagged with the predefined VLAN. As a result, both kinds of traffic are segregated in order to provide better service to the voice traffic. • When a dot1p priority is associated with the Voice VLAN port instead of a VLAN ID, then the priority information is passed onto the VoIP phone using the LLDP-MED or CDP mechanism. By this method, the voice data coming from the VoIP phone is tagged with VLAN 0 and with the exchanged priority; thus regular data arriving on the switch is given the default priority of the port (default 0), and the voice traffic is received with a higher priority. You can configure the switch to override the data traffic CoS. This feature can override the 802.1 priority of the data traffic packets arriving at the port enabled for Voice VLAN. Therefore, any rogue client that is also connected to the Voice VLAN port does not deteriorate the voice traffic. Voice VLAN and LLDP-MED The interactions with LLDP-MED are important for Voice VLAN: • LLDP-MED notifies the Voice VLAN component of the presence and absence of a VoIP phone on the network. • The Voice VLAN component interacts with LLDP-MED for applying VLAN ID, priority, and tag information to the VoIP phone traffic. Private VLANs Private VLANs partition a standard VLAN domain into two or more subdomains. Each subdomain is defined by a primary VLAN and a secondary VLAN. The primary VLAN ID is the same for all subdomains that belong to a particular private VLAN instance. The secondary VLAN ID differentiates the subdomains from each other and provides layer 2 isolation between ports on the same private VLAN. The following types of VLANs can be configured in a private VLAN: • 654 Primary VLAN—Forwards the traffic from the promiscuous ports to isolated ports, community ports and other promiscuous ports in the same private VLAN. Only one primary VLAN can be configured per private VLAN. All ports within a private VLAN share the same primary VLAN. Configuring VLANs • Isolated VLAN—A secondary VLAN. It carries traffic from isolated ports to promiscuous ports. Only one isolated VLAN can be configured per private VLAN. • Community VLAN—A secondary VLAN. It forwards traffic between ports which belong to the same community and to the promiscuous ports. There can be multiple community VLANs per private VLAN. A port may be designated as one of the following types in a private VLAN: • Promiscuous port—A port associated with a primary VLAN that is able to communicate with all interfaces in the private VLAN, including other promiscuous ports, community ports and isolated ports. • Host port—A port associated with a secondary VLAN that can either communicate with the promiscuous ports in the VLAN and with other ports in the same community (if the secondary VLAN is a community VLAN) or can communicate only with the promiscuous ports (if the secondary VLAN is an isolated VLAN). Private VLANs may be configured across a stack and on physical and portchannel interfaces. Private VLAN Usage Scenarios Private VLANs are typically implemented in a DMZ for security reasons. Servers in a DMZ are generally not allowed to communicate with each other but they must communicate to a router, through which they are connected to the users. Such servers are connected to host ports, and the routers are attached to promiscuous ports. Then, if one of the servers is compromised, the intruder cannot use it to attack another server in the same network segment. The same traffic isolation can be achieved by assigning each port with a different VLAN, allocating an IP subnet for each VLAN, and enabling layer 3 routing between them. In a private VLAN domain, on the other hand, all members can share the common address space of a single subnet, which is associated with a primary VLAN. So, the advantage of the private VLANs feature is that it reduces the number of consumed VLANs, improves IP addressing space utilization, and helps to avoid layer 3 routing. Configuring VLANs 655 Figure 21-3 shows an example Private VLAN scenario, in which five hosts (HA through H-E) are connected to a stack of switches (SW1, SW2). The switch stack is connected to router R1. Port references shown are with reference to the stack. Figure 21-3. Private VLAN Domain R1 TE1/1/1 SW1 Gi1/0/10 H-A SW2 Gi1/0/12 Gi1/0/11 H-B H-C Gi2/0/10 H-D Gi2/0/11 H-E Promiscuous Ports An endpoint connected to a promiscuous port is allowed to communicate with any endpoint within the private VLAN. Multiple promiscuous ports can be defined for a single private VLAN domain. In the configuration shown in Figure 21-3, the port connected from SW1 to R1 (TE1/1/1) is configured as a promiscuous port. It is possible to configure a port-channel as a promiscuous port in order to provide a level of redundancy on the private VLAN uplink. 656 Configuring VLANs Isolated Ports An endpoint connected to an isolated port is allowed to communicate with endpoints connected to promiscuous ports only. Endpoints connected to adjacent isolated ports cannot communicate with each other. Community Ports An endpoint connected to a community port is allowed to communicate with the endpoints within a community and can also communicate with any configured promiscuous port. The endpoints that belong to one community cannot communicate with endpoints that belong to a different community, or with endpoints connected to isolated ports. Private VLAN Operation in the Switch Stack and Inter-switch Environment The Private VLAN feature is supported in a stacked switch environment. The stack links are transparent to the configured VLANs; thus, there is no need for special private VLAN configuration beyond what would be configured for a single switch. Any private VLAN port can reside on any stack member. To enable private VLAN operation across multiple switches that are not stacked, trunk ports must be configured between the switches to transport the private VLANs. The trunk ports must be configured with the promiscuous, isolated, and community VLANs. Trunk ports must also be configured on all devices separating the switches. In regular VLANs, ports in the same VLAN switch traffic at L2. However, for a private VLAN, the promiscuous port forwards received traffic to secondary ports in the VLAN (isolated and community). Community ports forward received traffic to the promiscuous ports and other community ports using the same secondary VLAN. Isolated ports transmit received traffic to the promiscuous ports only. The ports to which the broadcast traffic is forwarded depend on the type of port on which the traffic was received. If the received port is a host port, traffic is broadcast to all promiscuous and trunk ports. If the received port is a community port, the broadcast traffic is forwarded to all promiscuous, trunk, and community ports in the same secondary VLAN. A promiscuous port broadcasts traffic to other promiscuous ports, isolated ports, and community ports. Configuring VLANs 657 Table 21-3. Forwarding Rules for Traffic in Primary VLAN To From promiscuous community 1 community 2 isolated stack (trunk) promiscuous allow allow allow allow allow community 1 N/A N/A N/A N/A N/A community 2 N/A N/A N/A N/A N/A isolated N/A N/A N/A N/A N/A stack (trunk) allow allow allow allow allow Table 21-4. Forwarding Rules for Traffic in Community 1 VLAN To From promiscuous community 1 community 2 isolated stack (trunk) promiscuous N/A N/A N/A N/A N/A community 1 allow allow deny deny allow community 2 N/A N/A N/A N/A N/A isolated N/A N/A N/A N/A N/A stack (trunk) allow allow deny deny allow Table 21-5. Forwarding Rules for Traffic in Isolated VLAN To 658 From promiscuous community 1 community 2 isolated stack (trunk) promiscuous N/A N/A N/A N/A N/A community 1 N/A N/A N/A N/A N/A community 2 N/A N/A N/A N/A N/A isolated allow deny deny deny allow stack (trunk) allow deny deny deny Allow Configuring VLANs Limitations and Recommendations • Only a single isolated VLAN can be associated with a primary VLAN. Multiple community VLANs can be associated with a primary VLAN. • Trunk and general modes are not supported on private VLAN ports. • Do not configure access ports using the VLANs participating in any of the private VLANs. • Multiple primary VLANs may be configured. Each primary VLAN must be unique and each defines a separate private VLAN domain. The operator must take care to use only the secondary VLANs associated with the primary VLAN of a domain. • Private VLANs cannot be enabled on a preconfigured interface. The interface must physically exist in the switch. • Secondary (community and isolated) VLANS are associated to the same multiple spanning tree instance as the primary VLAN. • GVRP/MVRP cannot be enabled after the private VLAN is configured. The administrator will need to disable both before configuring the private VLAN. • DHCP snooping can be configured on the primary VLAN. If it is enabled for a secondary VLAN, the configuration does not take effect if a primary VLAN is already configured. • If IP source guard is enabled on private VLAN ports, then DHCP snooping must be enabled on the primary VLAN. • Do not configure private VLAN ports on interfaces configured for voice VLAN. • If static MAC addresses are added for the host port, the same static MAC address entry must be added to the associated primary VLAN. This does not need to be replicated for dynamic MAC addresses. • A private VLAN cannot be enabled on a management VLAN. • A private VLAN cannot be enabled on the default VLAN. • VLAN routing can be enabled on private VLANs. It is not very useful to enable routing on secondary VLANs, as the access to them is restricted. However, primary VLANs can be enabled for routing. Configuring VLANs 659 • It is recommended that the private VLAN IDs be removed from the trunk ports connected to devices that do not participate in the private VLAN traffic. Private VLAN Configuration Example See "Configuring a Private VLAN" on page 711. Additional VLAN Features The Dell Networking series switches also support the following VLANs and VLAN-related features: 660 • VLAN routing interfaces — See "Configuring Routing Interfaces" on page 1021. • Guest VLAN — See "Configuring Port and System Security" on page 503. Configuring VLANs Default VLAN Behavior One VLAN is configured on the Dell Networking series switches by default. The VLAN ID is 1, and all ports are included in the VLAN as access ports, which are untagged. This means when a device connects to any port on the switch, the port forwards the packets without inserting a VLAN tag. If a device sends a tagged frame to a port with a VLAN ID other than 1, the frame is dropped. Since all ports are members of this VLAN, all ports are in the same broadcast domain and receive all broadcast and multicast traffic received on any port. When you create a new VLAN, all trunk ports are members of the VLAN by default. The configurable VLAN range is 2–4093. VLANs 4094 and 4095 are reserved for internal system use. Ports in trunk and access mode have the default behavior shown in Table 21-2 and cannot be configured with different tagging or ingress filtering values. When you add a VLAN to a port in general mode, the VLAN has the behavior shown in Table 21-6. Table 21-6. General mode Default Settings Feature Default Value Frames accepted Untagged Incoming untagged frames are classified into the VLAN whose VLAN ID is the currently configured PVID. Frames sent Untagged Ingress Filtering On PVID 1 Configuring VLANs 661 Table 21-7 shows the default values or maximum values for VLAN features. Table 21-7. Additional VLAN Default and Maximum Values Feature Value Default VLAN VLAN 1 VLAN Name No VLAN name is configured except for VLAN 1, whose name “default” cannot be changed. VLAN Range 2–4093 Switchport mode Access Double-VLAN tagging Disabled If double-VLAN tagging is enabled, the default EtherType value is 802.1Q Maximum number of configurable MAC-to-VLAN bindings 128 Maximum number of 64 configurable IP Subnet-to-VLAN bindings GVRP Disabled If GVRP is enabled, the default per-port parameters are: • GVRP State: Disabled • Dynamic VLAN Creation: Enabled • GVRP Registration: Enabled Number of dynamic VLANs 1024 that can be assigned through GVRP Voice VLAN Disabled Voice VLAN DSCP value 46 Voice VLAN authentication mode Enabled 662 Configuring VLANs Configuring VLANs (Web) This section provides information about the OpenManage Switch Administrator pages for configuring and monitoring VLANs on a Dell Networking N2000, N3000, and N4000 series switches. For details about the fields on a page, click at the top of the page. VLAN Membership Use the VLAN Membership page to create VLANs and define VLAN groups stored in the VLAN membership table. To display the VLAN Membership page, click Switching → VLAN → VLAN Membership in the navigation panel. The VLAN Membership tables display which Ports and LAGs are members of the VLAN, and whether they’re tagged (T), untagged (U), or forbidden (F). The tables have two rows: Static and Current. Only the Static row is configurable. The Current row is updated either dynamically through GVRP or when the Static row is changed and Apply is clicked. There are two tables on the page: • Ports — Displays and assigns VLAN membership to ports. To assign membership, click in Static for a specific port. Each click toggles between U, T, and blank. See Table 21-8 for definitions. • LAGs — Displays and assigns VLAN membership to LAGs. To assign membership, click in Static for a specific LAG. Each click toggles between U, T, and blank. See Table 21-8 for definitions. Table 21-8. VLAN Port Membership Definitions Port Control Definition T Tagged: the interface is a member of a VLAN. All packets forwarded by the interface in this VLAN are tagged. The packets contain VLAN information. U Untagged: the interface is a VLAN member. Packets forwarded by the interface in this VLAN are untagged. F Forbidden: indicates that the interface is forbidden from becoming a member of the VLAN. This setting is primarily for GVRP, which enables dynamic VLAN assignment. Configuring VLANs 663 Table 21-8. VLAN Port Membership Definitions Port Control Definition Blank Blank: the interface is not a VLAN member. Packets in this VLAN are not forwarded on this interface. To perform additional port configuration, such as making the port a trunk port, use the Port Settings page. Figure 21-4. VLAN Membership Adding a VLAN To create a VLAN: 1 Open the VLAN Membership page. 2 Click Add to display the Add VLAN page. 3 Specify a VLAN ID and a VLAN name. 664 Configuring VLANs Figure 21-5. Add VLAN 4 Click Apply. Configuring Ports as VLAN Members To add member ports to a VLAN: 1 Open the VLAN Membership page. 2 From the Show VLAN menu, select the VLAN to which you want to assign ports. 3 In the Static row of the VLAN Membership table, click the blank field to assign the port as an untagged member. Figure 21-6 shows 10-Gigabit Ethernet ports 8–10 being added to VLAN 300. Configuring VLANs 665 Figure 21-6. Add Ports to VLAN 4 Click Apply. 5 Verify that the ports have been added to the VLAN. 666 Configuring VLANs In Figure 21-7, the presence of the letter U in the Current row indicates that the port is an untagged member of the VLAN. Figure 21-7. Add Ports to VLAN Configuring VLANs 667 VLAN Port Settings Use the VLAN Port Settings page to add ports to an existing VLAN and to configure settings for the port. If you select Trunk or Access as the Port VLAN Mode, some of the fields are not configurable because of the requirements for that mode. NOTE: You can add ports to a VLAN through the table on the VLAN Membership page or through the PVID field on the Port Settings page. The PVID is the VLAN that untagged received packets are assigned to. To include a general-mode port in multiple VLANs, use the VLAN Membership page. To display the Port Settings page, click Switching → VLAN → Port Settings in the navigation panel. Figure 21-8. VLAN Port Settings From the Port Settings page, click Show All to see the current VLAN settings for all ports. You can change the settings for one or more ports by clicking the Edit option for a port and selecting or entering new values. 668 Configuring VLANs Figure 21-9. VLAN Settings for All Ports VLAN LAG Settings Use the VLAN LAG Settings page to map a LAG to a VLAN and to configure specific VLAN settings for the LAG. To display the LAG Settings page, click Switching → VLAN → LAG Settings in the navigation panel. Figure 21-10. VLAN LAG Settings Configuring VLANs 669 From the LAG Settings page, click Show All to see the current VLAN settings for all LAGs. You can change the settings for one or more LAGs by clicking the Edit option for a port and selecting or entering new values. Figure 21-11. 670 VLAN LAG Table Configuring VLANs Bind MAC to VLAN Use the Bind MAC to VLAN page to map a MAC address to a VLAN. After the source MAC address and the VLAN ID are specified, the MAC to VLAN configurations are shared across all ports of the switch. The MAC to VLAN table supports up to 128 entries. To display the Bind MAC to VLAN page, click Switching → VLAN → Bind MAC to VLAN in the navigation panel. Figure 21-12. Bind MAC to VLAN From the Bind MAC to VLAN page, click Show All to see the MAC addresses that are mapped to VLANs. From this page, you can change the settings for one or more entries or remove an entry. Figure 21-13. MAC-VLAN Bind Table Configuring VLANs 671 Bind IP Subnet to VLAN Use the Bind IP Subnet to VLAN page to assign an IP Subnet to a VLAN. The IP Subnet to VLAN configurations are shared across all ports of the switch. There can be up to 64 entries configured in this table. To display the Bind IP Subnet to VLAN page, click Switching → VLAN → Bind IP Subnet to VLAN in the navigation panel. Figure 21-14. Bind IP Subnet to VLAN From the Bind IP Subnet to VLAN page, click Show All to see the IP subnets that are mapped to VLANs. From this page, you can change the settings for one or more entries or remove an entry. Figure 21-15. 672 Subnet-VLAN Bind Table Configuring VLANs GVRP Parameters Use the GVRP Parameters page to enable GVRP globally and configure the port settings. To display the GVRP Parameters page, click Switching → VLAN → GVRP Parameters in the navigation panel. Figure 21-16. GVRP Parameters From the GVRP Parameters page, click Show All to see the GVRP configuration for all ports. From this page, you can change the settings for one or more entries. NOTE: Per-port and per-LAG GVRP Statistics are available from the Statistics/RMON page. For more information, see "Monitoring Switch Traffic" on page 407. Configuring VLANs 673 Figure 21-17. 674 GVRP Port Parameters Table Configuring VLANs Protocol Group Use the Protocol Group page to configure which EtherTypes go to which VLANs, and then enable certain ports to use these settings. Protocol-based VLANs are most often used in situations where network segments contain hosts running multiple protocols. To display the Protocol Group page, click Switching → VLAN → Protocol Group in the navigation panel. Figure 21-18. Protocol Group Configuring VLANs 675 Adding a Protocol Group To add a protocol group: 1 Open the Protocol Group page. 2 Click Add to display the Add Protocol Group page. 3 Create a name for the group and associate a VLAN with the group. Figure 21-19. Add Protocol Group 4 Click Apply. 5 Click Protocol Group to return to the main Protocol Group page. 6 From the Group ID field, select the group to configure. 7 In the Protocol Settings table, select the protocol and interfaces to associate with the protocol-based VLAN. In Figure 21-20, the Protocol Group 1 (named IPX) is associated with the IPX protocol and ports 14–16. Ports 20-22 are selected in Available Ports list. After clicking the right arrow, they will be added to the Selected Ports list. 676 Configuring VLANs Figure 21-20. Configure Protocol Group 8 Click Apply. 9 Click Show All to see the protocol-based VLANs and their members. Figure 21-21. Protocol Group Table Configuring VLANs 677 Double VLAN Global Configuration Use the Double VLAN Global Configuration page to specify the value of the EtherType field in the first EtherType/tag pair of the double-tagged frame. To display the Double VLAN Global Configuration page, click Switching → VLAN → Double VLAN → Global Configuration in the navigation panel. Figure 21-22. 678 Double VLAN Global Configuration Configuring VLANs Double VLAN Interface Configuration Use the Double VLAN Interface Configuration page to specify the value of the EtherType field in the first EtherType/tag pair of the double-tagged frame. To display the Double VLAN Interface Configuration page, click Switching → VLAN → Double VLAN → Interface Configuration in the navigation panel. Figure 21-23. Double VLAN Interface Configuration To view a summary of the double VLAN configuration for all interfaces and to edit settings for one or more interfaces, click Show All. Configuring VLANs 679 Figure 21-24. 680 Double VLAN Port Parameter Table Configuring VLANs Voice VLAN Use the Voice VLAN Configuration page to configure and view voice VLAN settings that apply to the entire system and to specific interfaces. To display the page, click Switching → VLAN → Voice VLAN → Configuration in the navigation panel. Figure 21-25. Voice VLAN Configuration NOTE: IEEE 802.1X must be enabled on the switch before you disable voice VLAN authentication. Voice VLAN authentication can be disabled in order to allow VoIP phones that do not support authentication to send and receive unauthenticated traffic on the Voice VLAN. Configuring VLANs 681 Configuring VLANs (CLI) This section provides information about the commands you use to create and configure VLANs. For more information about the commands, see the Dell Networking N2000, N3000, and N4000 Series Switches CLI Reference Guide at support.dell.com/manuals. Creating a VLAN Beginning in Privileged EXEC mode, use the following commands to configure a VLAN and associate a name with the VLAN. Command Purpose configure Enter global configuration mode. vlan {vlan-id |vlanrange} Create a new VLAN or a range of VLANs and enter the interface configuration mode for the specified VLAN or VLAN range. • vlan-id—A valid VLAN IDs (Range: 2–4093). • vlan-range — A list of valid VLAN IDs to be added. List separate, non-consecutive VLAN IDs separated by commas (without spaces); use a hyphen to designate a range of IDs. (Range: 2–4093) name string Add a name to the specified VLAN. string — Comment or description to help identify a specific VLAN (Range: 1–32 characters). CTRL + Z Exit to Privileged EXEC mode. show vlan [id vlan-id | name vlan-name] Display VLAN information. • vlan-id — A valid VLAN ID. (Range: 1–4093) • vlan-name — A valid VLAN name string. (Range: 1–32 characters) Configuring a Port in Access Mode Beginning in Privileged EXEC mode, use the following commands to configure an access mode VLAN interface and, optionally, assign the interface to a VLAN. When a port is in access mode, it can only be a member of one VLAN and will accept tagged packets with the access VLAN ID or untagged 682 Configuring VLANs packets. Untagged packets are treated as belonging to the access VLAN. Packets received with a VLAN ID other than the access VLAN ID are discarded. When you configure an interface as an access mode port, the interface is automatically made a member of VLAN 1 and removed from all other VLAN memberships. You can configure each interface separately, or you can configure a range of interfaces with the same settings. Command Purpose configure Enter global configuration mode. interface interface Enter interface configuration mode for the specified interface. The interface variable includes the interface type and number, for example tengigabitethernet 1/0/3. You can also specify a range of interfaces with the interface range command, for example, interface range tengigabitethernet 1/0/8-12 configures interfaces 8, 9, 10, 11, and 12. switchport mode access Configure the interface as an access mode VLAN interface. Access mode VLANs accept tagged or untagged packets for the access VLAN only. switchport access vlan Configure the interface as a member of the specified VLAN. By default, access mode ports are members of VLAN 1. vlan-id vlan-id — A valid VLAN ID of the VLAN to which the port is configured. (Range: 1–4093) CTRL + Z Exit to Privileged EXEC mode. show interfaces switchport interface Display information about the VLAN settings configured for the specified interface. Configuring a Port in Trunk Mode Beginning in Privileged EXEC mode, use the following commands to configure an interface as a layer 2 trunking interface, which connects two switches. Trunk mode ports support traffic tagged with different VLAN IDs. Untagged received traffic is switched in the native VLAN. A trunk port is Configuring VLANs 683 automatically configured as a member of all VLANs. You can remove them from membership in specific VLANs. By default, the native VLAN for a trunk port is VLAN 1. Command Purpose configure Enter global configuration mode. interface interface Enter interface configuration mode for the specified interface. The interface variable includes the interface type and number, for example tengigabitethernet 1/0/3. You can also specify a range of interfaces with the interface range command, for example, interface range tengigabitethernet 1/0/8-12 configures interfaces 8, 9, 10, 11, and 12. switchport mode trunk 684 Configure the interface as a tagged layer 2 VLAN interface. Configuring VLANs Command Purpose switchport trunk Set the list of allowed VLANs that can receive and send {allowed vlan vlantraffic on this interface in tagged format when in trunking list|native vlan vlan-id} mode. • allowed vlan-list — Set the list of allowed VLANs that can receive and send traffic on this interface in tagged format when in trunking mode. Separate non-consecutive VLAN IDs with a comma and no spaces. Use a hyphen to designate a range of IDs. The vlan-list format is all | [add | remove | except] vlanatom [vlan-atom...] where: • all—Specifies all VLANs from 1 to 4093. This keyword is not allowed on commands that do not permit all VLANs in the list to be set at the same time. • add—Adds the list of VLANs to the allowed set. • remove—Removes the list of VLANs from the allowed set. Removing the native VLAN from a trunk port forces the port to allow tagged packets only. • except—Allows all VLANs other than those in the list. • vlan-atom —Either a single VLAN number from 1 to 4093 or a continuous range of VLANs described by two VLAN numbers, the lesser one first, separated by a hyphen. • native vlan-id— The untagged VLAN. Untagged packets received on this interface are switched in the native VLAN. Transmitted packets in this VLAN are sent untagged. CTRL + Z Exit to Privileged EXEC mode. show interfaces switchport interface Display information about the VLAN settings configured for the specified interface. The interface variable includes the interface type and number. Configuring VLANs 685 Configuring a Port in General Mode Beginning in Privileged EXEC mode, use the following commands to configure an interface with full 802.1q support and configure the VLAN membership information for the interface. Except when noted as required (for example, when configuring MAB, Voice VLAN, or 802.1x), it is recommended that operators use either trunk or access mode. Command Purpose configure Enter global configuration mode. interface interface Enter interface configuration mode for the specified interface. The interface variable includes the interface type and number, for example tengigabitethernet 1/0/3. You can also specify a range of interfaces with the interface range command, for example, interface range tengigabitethernet 1/0/8-12 configures interfaces 8, 9, 10, 11, and 12. switchport mode general Configure the interface as a tagged and an untagged layer 2 VLAN interface. switchport general allowed vlan [add|remove] vlan-list {tagged|untagged} Configure the VLAN membership for the port. You can also use this command to change the egress tagging for packets without changing the VLAN assignment. • add vlan-list — List of VLAN IDs to add. Separate nonconsecutive VLAN IDs with a comma and no spaces. Use a hyphen to designate a range of IDs. (Range: 1–4093) • remove vlan-list — List of VLAN IDs to remove. Separate nonconsecutive VLAN IDs with a comma and no spaces. Use a hyphen to designate a range of IDs. • tagged — Sets the port to transmit tagged packets for the VLANs. If the port is added to a VLAN without specifying tagged or untagged, the default is untagged. • untagged — Sets the port to transmit untagged packets for the VLANs. 686 Configuring VLANs Command Purpose switchport general pvid (Optional) Set the port VLAN ID. Untagged traffic that enters the switch through this port is tagged with the PVID. vlan-id vlan-id — PVID. The selected PVID assignment must be to an existing VLAN. (Range: 1–4093). Entering a PVID value does not remove the previous PVID value from the list of allowed VLANs. switchport general acceptable-frame-type tagged-only (Optional) Specifies that the port will only accept tagged frames. Untagged frames are dropped at ingress. switchport general ingress-filtering disable (Optional) Turn off ingress filtering so that all received tagged frames are forwarded whether or not the port is a member of the VLAN in the tag. CTRL + Z Exit to Privileged EXEC mode. show interfaces switchport interface Display information about the VLAN settings configured for the specified interface. The interface variable includes the interface type and number. Configuring VLANs 687 Configuring VLAN Settings for a LAG The VLAN mode and memberships settings you configure for a port are also valid for a LAG (port-channel). Beginning in Privileged EXEC mode, use the following commands to configure the VLAN mode for a LAG. Once you specify the switchport mode settings for a LAG, you can configure other VLAN memberships settings that are valid that the switchport mode. Command Purpose configure Enter global configuration mode. interface port-channel Enter interface configuration mode for the specified interface. channel-id channel-id — Specific port-channel. (Range 1–48). You can also specify a range of LAGs with the interface range port-channel command, for example, interface range portchannel 4-8. switchport mode [access|general|trunk] Configure the interface as an untagged layer 2 VLAN interface. CTRL + Z Exit to Privileged EXEC mode. show interfaces Display information about the VLAN settings configured switchport port-channel for the specified LAG. channel-id 688 Configuring VLANs Configuring Double VLAN Tagging Beginning in Privileged EXEC mode, use the following commands to configure an interface to send and accept frames with double VLAN tagging. DVLAN uplink interfaces must be configured for tagging (trunk mode) for double tags to be observed on frames egressing the interface. DVLAN uplink interfaces should be configured to accept tagged frames for the DVLAN or outer VLAN. Ensure that the native VLAN on the uplink port is set to the DVLAN ID. MAC address learning on DVLAN enabled ports occurs on the DVLAN uplink port's native VLAN. Enabling DVLAN tunneling configures all ports in the system as access ports except those configured as uplink ports. Access ports must be configured with the uplink ports native VLAN as their PVID. Command Purpose configure Enter global configuration mode. vlan 100 Configure the DVLAN (outer) VLAN. exit Exit VLAN configuration mode interface interface Enter interface configuration mode for the specified interface. The interface variable includes the interface type and number, for example tengigabitethernet 1/0/3. You can also specify a range of interfaces with the interface range command, for example, interface range tengigabitethernet 1/0/8-12 configures interfaces 8, 9, 10, 11, and 12. switchport mode trunk Configure the interface as tagging. switchport trunk native vlan 100 Configure MAC learning on the DVLAN VLAN mode dvlan-tunnel Enable Double VLAN Tunneling on the uplink (service provider) interface. exit Exit to global configuration mode Configuring VLANs 689 Command Purpose dvlan-tunnel ethertype {802.1Q | vman | custom <0-65535>} [primary-tpid] Configure the EtherType to use for uplink or access interfaces. • 802.1Q — Configures the EtherType as 0x8100 (default). • vman — Configures the EtherType as 0x88A8. • custom — Custom configures the EtherType for the DVLAN tunnel. The value must be 0-65535. • primary-tpid — Configure the primary (outer) TPID. If this parameter is not present, the inner TPID is configured. Only a single outer TPID may be configured for a switch. The inner VLAN TPID can be configured on all interfaces or on individual interfaces. CTRL + Z Exit to Privileged EXEC mode. show dvlan-tunnel Display all interfaces enabled for Double VLAN Tunneling show dvlan-tunnel interface {interface | all} Display detailed information about Double VLAN Tunneling for the specified interface or all interfaces. 690 Configuring VLANs Configuring MAC-Based VLANs Beginning in Privileged EXEC mode, use the following commands to associate a MAC address with a configured VLAN. The VLAN does not need to be configured on the system to associate a MAC address with it. You can create up to 256 VLAN to MAC address associations. Command Purpose configure Enter global configuration mode. vlan 10 Enter VLAN 10 configuration mode. vlan association mac Associate a MAC address with a VLAN. mac-address • mac-address — MAC address to associate. (Range: Any MAC address in the format xxxx.xxxx.xxxx or xx:xx:xx:xx:xx:xx) CTRL + Z Exit to Privileged EXEC mode. show vlan association mac [mac-address] Display the VLAN associated with a specific configured MAC address. If no MAC address is specified, the VLAN associations of all the configured MAC addresses are displayed. Configuring VLANs 691 Configuring IP-Based VLANs Beginning in Privileged EXEC mode, use the following commands to associate an IP subnet with a configured VLAN. The VLAN does not need to be configured on the system to associate an IP subnet with it. You can create up to 256 VLAN to MAC address associations. Command Purpose configure Enter global configuration mode. vlan 10 Enter VLAN 10 configuration mode. vlan association subnet Associate an IP subnet with a VLAN. ip-address subnet-mask vlanid • ip-address — Source IP address. (Range: Any valid IP address) • subnet-mask — Subnet mask. (Range: Any valid subnet mask) • vlanid — VLAN to associated with subnet. (Range: 14093) CTRL + Z Exit to Privileged EXEC mode. show vlan association subnet [ip-address ip- Display the VLAN associated with a specific configured IPAddress and netmask. If no IP Address and net mask are specified, the VLAN associations of all the configured IPsubnets are displayed. mask ] 692 Configuring VLANs Configuring a Protocol-Based VLAN Beginning in Privileged EXEC mode, use the following commands to create and name a protocol group, and associate VLANs with the protocol group. When you create a protocol group, the switch automatically assigns it a unique group ID number. The group ID is used for both configuration and script generation to identify the group in subsequent commands. A protocol group may have more than one interface associated with it, but each interface and protocol combination can be associated with one group only. If adding an interface to a group causes any conflicts with protocols currently associated with the group, adding the interface(s) to the group fails and no interfaces are added to the group. Ensure that the referenced VLAN is created prior to the creation of the protocol-based group except when GVRP is expected to create the VLAN. Command Purpose configure Enter global configuration mode. vlan protocol group Create a new protocol group. exit Exit to Privileged EXEC mode. show port protocol all Obtain the group ID for the newly configured group. configure Enter global configuration mode. name vlan protocol group add Add any EtherType protocol to the protocol-based VLAN protocol groupid groups identified by groupid. A group may have more than ethertype value one protocol associated with it. Each interface and protocol combination can be associated with one group only. If adding a protocol to a group causes any conflicts with interfaces currently associated with the group, this command fails and the protocol is not added to the group. • groupid — The protocol-based VLAN group ID. • protocol — The protocol you want to add. The ethertype can be any valid number in the range 0x0600-0xffff. Configuring VLANs 693 Command Purpose protocol vlan group all (Optional) Add all physical interfaces to the protocolbased group identified by groupid. You can add individual interfaces to the protocol-based group as shown in the next two commands. groupid groupid — The protocol-based VLAN group ID. interface interface Enter interface configuration mode for the specified interface. interface — Specific interface type and number, such as gi1/0/8. protocol vlan group groupid Add the physical unit/port interface to the protocol-based group identified by groupid. groupid — The protocol-based VLAN group ID. exit Exit to global configuration mode. vlan 5 Enter VLAN 5 configuration mode. protocol group groupid Attach a VLAN ID to the protocol-based group identified by groupid. A group may only be associated with one VLAN at a time. However, the VLAN association can be changed. vlanid • groupid — The protocol-based VLAN group ID, which is automatically generated when you create a protocolbased VLAN group with the vlan protocol group command. To see the group ID associated with the name of a protocol group, use the show port protocol all command. • vlanid — A valid VLAN ID. CTRL + Z Exit to Privileged EXEC mode. show port protocol [all| Display the Protocol-Based VLAN information for either groupid] the entire system or for the indicated group. 694 Configuring VLANs Configuring GVRP Beginning in Privileged EXEC mode, use the following commands to enable GVRP on the switch and on an interface, and to configure various GVRP settings. Command Purpose configure Enter global configuration mode. gvrp enable Enable GVRP on the switch. interface interface Enter interface configuration mode for the specified port or LAG. The interface variable includes the interface type and number, for example tengigabitethernet 1/0/3 or portchannel 3. You can also specify a range of interfaces with the interface range command, for example, interface range tengigabitethernet 1/0/8-12 configures interfaces 8, 9, 10, 11, and 12. gvrp enable Enable GVRP on the interface. switchport general forbidden vlan {add vlan-list|remove vlanlist} (Optional) Forbids dynamically adding the VLANs specified by the remove parameter to a port. To revert to allowing the addition of specific VLANs to the port, use the add parameter of this command. add vlan-list — List of valid VLAN IDs to remove from the forbidden list. Separate nonconsecutive VLAN IDs with a switchport trunk allowed comma and no spaces. Use a hyphen to designate a range vlan {add vlan-list | of IDs. remove vlan-list} remove vlan-list — List of valid VLAN IDs to add to the forbidden list. Separate nonconsecutive VLAN IDs with a comma and no spaces. Use a hyphen to designate a range of IDs. —and— gvrp registration-forbid (Optional) Deregister all VLANs on a port and prevent any dynamic registration on the port. gvrp vlan-creationforbid (Optional) Disable dynamic VLAN creation. exit Exit to global configuration mode. Configuring VLANs 695 Command Purpose vlan makestatic vlan-id (Optional) Change a dynamically created VLAN (one that is created by GVRP registration) to a static VLAN (one that is permanently configured and defined). vlan-id — Valid vlan ID. Range is 2-4093. CTRL + Z Exit to Privileged EXEC mode. show gvrp configuration Display GVRP configuration information. Timer values are displayed. Other data shows whether GVRP is enabled and which ports are running GVRP. show vlan 696 Display the VLAN configuration, including the VLAN configuration type and the associated ports. Configuring VLANs Configuring Voice VLANs Beginning in Privileged EXEC mode, use the following commands to enable the Voice VLAN feature on the switch and on an interface. Command Purpose configure Enter global configuration mode. voice vlan Enable the voice VLAN capability on the switch. interface interface Enter interface configuration mode for the specified interface. interface — Specific interface, such as gi1/0/8. You can also specify a range of interfaces with the interface range command, for example, interface range gi1/0/8-12 enters Interface Configuration mode for ports 8–12. voice vlan {vlanid | Enable the voice vlan capability on the interface. dot1p priority | none | • vlanid —The voice VLAN ID. untagged | data priority {trust | untrust} | auth • priority —The Dot1p priority for the voice VLAN on the port. {enable | disable} | dscp value} • trust—Trust the dot1p priority or DSCP values contained in packets arriving on the voice vlan port. • untrust—Do not trust the dot1p priority or DSCP values contained in packets arriving on the voice vlan port. • auth {enable | disable} — Use enable to allow voice traffic on unauthorized voice vlan port. Use disable to prevent voice traffic on an Unauthorized voice vlan port • dscp value —The DSCP value (Range: 0–64). CTRL + Z Exit to Privileged EXEC mode. show voice vlan [interface {interface |all}] Display voice VLAN configuration information for the switch, for the specified interface, or for all interfaces. Configuring VLANs 697 VLAN Configuration Examples This section contains the following examples: • Configuring VLANs Using Dell OpenManage Administrator • Configuring VLANs Using the CLI • Configuring a Voice VLAN NOTE: For an example that shows how to use a RADIUS server to provide VLAN information, see "Controlling Authentication-Based VLAN Assignment" on page 530. For an example that shows how to allow the switch to dynamically create RADIUS-assigned VLANS, see "Allowing Dynamic VLAN Creation of RADIUS-Assigned VLANs" on page 534. This example assumes that network administrator wants to create the VLANs in Table 21-9: Table 21-9. Example VLANs VLAN ID VLAN Name VLAN Type Purpose 100 Engineering Port-based All employees in the Engineering department use this VLAN. Confining this department’s traffic to a single VLAN helps reduce the amount of traffic in the broadcast domain, which increases bandwidth. 200 Marketing Port-based All employees in the Marketing department use this VLAN. 300 Sales MAC-based The sales staff works remotely but occasionally comes to the office. Since these employees do not have assigned work areas, they typically plug their laptops into a network port in an available cubicle, office, or conference room. 400 Payroll Port-based 698 Configuring VLANs The payroll department has sensitive traffic and needs its own VLAN to help keep that traffic private. Figure 21-26 shows the network topology for this example. As the figure shows, there are two switches, two file servers, and many hosts. One switch has an uplink port that connects it to a layer 3 device and the rest of the corporate network. Figure 21-26. Network Topology for Port-Based VLAN Configuration LAN/WAN Switch 1 VLAN 400 Payroll Payroll Server Switch 2 VLAN 100 Engineering VLAN 200 Marketing Payroll Hosts Marketing Hosts Shared File Engineering Server Hosts The network in Figure 21-26 has the following characteristics: • Each connection to a host represents multiple ports and hosts. • The Payroll and File servers are connected to the switches through a LAG. • Some of the Marketing hosts connect to Switch 1, and some connect to Switch 2. • The Engineering and Marketing departments share the same file server. • Because security is a concern for the Payroll VLAN, the ports and LAG that are members of this VLAN will accept and transmit only traffic tagged with VLAN 400. • The Sales staff might connect to a port on Switch 1 or Switch 2. Configuring VLANs 699 Table 21-10 shows the port assignments on the switches. Table 21-10. Switch Port Connections Port/LAG Function Switch 1 1 Connects to Switch 2 2–15 Host ports for Payroll 16–20 Host ports for Marketing LAG1 (ports 21–24) Connects to Payroll server Switch 2 1 Connects to Switch 1 2–10 Host ports for Marketing 11–30 Host ports for Engineering LAG1 (ports 35–39) Connects to file server LAG2 (ports 40–44) Uplink to router. 700 Configuring VLANs Configuring VLANs Using Dell OpenManage Administrator This example shows how to perform the configuration by using the webbased interface. Configure the VLANs and Ports on Switch 1 Use the following steps to configure the VLANs and ports on Switch 1. None of the hosts that connect to Switch 1 use the Engineering VLAN (VLAN 100), so it is not necessary to create it on that switch. To configure Switch 1: 1 Create the Marketing, Sales, and Payroll VLANs. a From the Switching → VLAN → VLAN Membership page, click Add. b In the VLAN ID field, enter 200. c In the VLAN Name field, enter Marketing. d Click Apply. Figure 21-27. e Add VLANs Repeat steps b–d to create VLANs 300 (Sales) and 400 (Payroll). 2 Assign ports 16–20 to the Marketing VLAN. a From the Switching → VLAN → VLAN Membership page, select 200-Marketing from the Show VLAN field. b In the Static row, click the space for ports 13–16 so the U (untagged) displays for each port. Configuring VLANs 701 Figure 21-28. VLAN Membership - VLAN 200 3 Click Apply. 4 Assign ports 2–15 and LAG1 to the Payroll VLAN. a From the Switching → VLAN → VLAN Membership page, select 400-Payroll from the Show VLAN field. b In the Static row, click the space for ports 2–15 and LAG 1 so the U (untagged) displays for each port, and then click Apply. 5. Configure LAG 1 to be in general mode and specify that the LAG will accept tagged or untagged frames, but that untagged frames will be transmitted tagged with PVID 400. a. From the Switching → VLAN → LAG Settings page, make sure Po1 is selected. b. Configure the following settings: c. 702 • Port VLAN Mode — General • PVID — 400 • Frame Type — AdmitAll Click Apply. Configuring VLANs Figure 21-29. LAG Settings 6 Configure port 1 as a trunk port. a From the Switching → VLAN → Port Settings page, make sure port Gi1/0/1 is selected. b From the Port VLAN Mode field, select Trunk. c Click Apply. Figure 21-30. Trunk Port Configuration 7 From the Switching → VLAN → VLAN Membership page, verify that port 1 is marked as a tagged member (T) for each VLAN. Figure 21-31 shows VLAN 200, in which port 1 is a tagged member, and ports 13–16 are untagged members. Configuring VLANs 703 Figure 21-31. Trunk Port Configuration 8 Configure the MAC-based VLAN information. a Go to the Switching → VLAN → Bind MAC to VLAN page. b In the MAC Address field, enter a valid MAC address, for example 00:1C:23:55:E9:8B. c In the Bind to VLAN field, enter 300, which is the Sales VLAN ID. d Click Apply. Figure 21-32. e Trunk Port Configuration Repeat steps b–d to add additional MAC address-to-VLAN information for the Sales department. 9 To save the configuration so that it persists across a system reset, use the following steps: 704 a Go to the System → File Management→ Copy Files page b Select Copy Configuration and ensure that Running Config is the source and Startup Config is the destination. c Click Apply. Configuring VLANs Configure the VLANs and Ports on Switch 2 Use the following steps to configure the VLANs and ports on Switch 2. Many of the procedures in this section are the same as procedures used to configure Switch 1. For more information about specific procedures, see the details and figures in the previous section. To configure Switch 2: 1. Create the Engineering, Marketing, Sales, and Payroll VLANs. Although the Payroll hosts do not connect to this switch, traffic from the Payroll department must use Switch 2 to reach the rest of the network and Internet through the uplink port. For that reason, Switch 2 must be aware of VLAN 400 so that traffic is not rejected by the trunk port. 2. Configure LAG 1 as a general port so that it can be a member of multiple VLANs. a. From the Switching → VLAN → LAG Settings page, make sure Po1 is selected. b. From the Port VLAN Mode field, select General. c. Click Apply. 3. Configure port 1 as a trunk port. 4. Configure LAG2 as a trunk port. 5. Assign ports 1–10 to VLAN 200 as untagged (U) members. 6. Assign ports 11–30 to VLAN 100 as untagged (U) members. 7. Assign LAG1 to VLAN 100 and 200 as a tagged (T) member. 8. Assign port 1 and LAG2 to VLAN 100, VLAN 200, VLAN 300, and VLAN 400 as a tagged (T) member. 9. Configure the MAC-based VLAN information. 10. If desired, copy the running configuration to the startup configuration. Configuring VLANs 705 Configuring VLANs Using the CLI This example shows how to perform the same configuration by using CLI commands. Configure the VLANs and Ports on Switch 1 Use the following steps to configure the VLANs and ports on Switch 1. None of the hosts that connect to Switch 1 use the Engineering VLAN (VLAN 100), so it is not necessary to create it on that switch. To configure Switch 1: 1. Create VLANs 200 (Marketing), 300 (Sales), and 400 (Payroll), and associate the VLAN ID with the appropriate name. console#configure console(config)#vlan 200,300,400 console(config)#vlan 200 console(config-vlan200)#name Marketing console(config-vlan200)#exit console(config)#vlan 300 console(config-vlan300)#name Sales console(config-vlan300)#exit console(config)#vlan 400 console(config-vlan400)#name Payroll console(config-vlan400)#exit 2. Assign ports 16–20 to the Marketing VLAN. console(config)#interface range tengigabitEthernet 1/0/16-20 console(config-if)#switchport mode access console(config-if)#switchport access vlan 200 console(config-if)#exit 3. Assign ports 2–15 to the Payroll VLAN console(config)#interface range tengigabitEthernet 1/0/2-15 console(config-if)#switchport mode access console(config-if)#switchport access vlan 400 console(config-if)#exit 706 Configuring VLANs 4. Assign LAG1 to the Payroll VLAN and specify that frames will always be transmitted tagged with a VLAN ID of 400. By default, all VLANs are members of a trunk port. console(config)#interface port-channel 1 console(config-if-Po1)#switchport mode trunk console(config-if-Po1)#switchport trunk native vlan 400 console(config-if-Po1)#exit 5. Configure port 1 as a trunk port and add VLAN 200, VLAN 300, and VLAN 400 as members. All VLANs are added to trunk ports by default, including those created after the trunk port has been created. console(config)#interface tengigabitEthernet 1/0/1 console(config-if-Te1/0/1)#switchport mode trunk console(config-if-Te1/0/1)#exit 6. Configure the MAC-based VLAN information. The following commands show how to associate a system with a MAC address of 00:1C:23:55:E9:8B with VLAN 300. Repeat the vlan association mac command to associate additional MAC addresses with VLAN 300. console(config)#vlan 10 console(config-vlan10)#vlan association mac 00:1C:23:55:E9:8B 300 console(config-vlan10)#exit console(config)#exit 7. To save the configuration so that it persists across a system reset, use the following command: console#copy running-config startup-config Configuring VLANs 707 8. View the VLAN settings. console#show vlan VLAN ----1 Name --------Default 200 Marketing 300 400 Sales Payroll Ports -----------Po1-1248, Te1/0/2-15, Te1/0/21-24 Te1/1/1-2 Te1/0/1, Te1/0/16-20 Te1/0/1 Te1/0/1-15 Type --------Default Authorization ------------Required Static Required Static Static Required Required 9. View the VLAN membership information for a port. console#show interfaces switchport te1/0/1 Port: Te1/0/1 VLAN Membership mode:Trunk Mode Operating parameters: PVID: 1 Ingress Filtering: Enabled Acceptable Frame Type: VLAN Only Default Priority: 0 GVRP status:Disabled Protected:Disabled Port Te1/0/1 is member in: VLAN ---200 300 400 708 Name Egress rule ----------------- ----------Marketing Tagged Sales Tagged Payroll Tagged Configuring VLANs Type -------Static Static Static Configure the VLANs and Ports on Switch 2 Use the following steps to configure the VLANs and ports on Switch 2. Many of the procedures in this section are the same as procedures used to configure Switch 1. For more information about specific procedures, see the details and figures in the previous section. To configure Switch 2: 1. Create the Engineering, Marketing, Sales, and Payroll VLANs. Although the Payroll hosts do not connect to this switch, traffic from the Payroll department must use Switch 2 to reach the rest of the network and Internet through the uplink port. For that reason, Switch 2 must be aware of VLAN 400 so that traffic is not rejected by the trunk port. 2. Configure ports 2-10 as access ports and add VLAN 200 to the ports. 3. Configure ports 11–30 as access ports and add VLAN 100 to the ports. 4. Configure LAG 1 as a general port so that it can be a member of multiple untagged VLANs and add VLAN 100 and VLAN 200 to the LAG. 5. Configure port 1 and LAG 2 trunk ports and add VLAN 100, VLAN 200, VLAN 300, and VLAN 400 to the port and LAG. 6. Configure the MAC-based VLAN information. 7. If desired, copy the running configuration to the startup configuration. 8 View VLAN information for the switch and ports. Configuring VLANs 709 Configuring a Voice VLAN The commands in this example create a VLAN for voice traffic with a VLAN ID of 25. Port 10 is set to an 802.1Q VLAN. In in this example, there are multiple devices connected to port 10, so the port must be in general mode in order to enable MAC-based 802.1X authentication. Next, Voice VLAN is enabled on the port with the Voice VLAN ID set to 25. Finally, Voice VLAN authentication is disabled on port 10 because the phone connected to that port does not support 802.1X authentication. All other devices are required to use 802.1X authentication for network access. For more information about 802.1X authentication, see "Configuring Port and System Security" on page 503. NOTE: In an environment where the IP phone uses LLDP-MED to obtain configuration information, an additional step to enable LLDP-MED on the interface would be required by issuing the lldp med command in Interface Configuration mode. To configure the switch: 1 Create the voice VLAN. console#configure console(config)#vlan 25 console(config-vlan25)#exit 2 Enable the Voice VLAN feature on the switch. console(config)#voice vlan 3 Configure port 10 to be in general mode. console(config)#interface gi1/0/10 console(config-if-Gi1/0/10)#switchport mode general 4 Enable port-based 802.1X authentication on the port. This step is required only if there are multiple devices that use port-based authentication connected to the port. console(config-if-Gi1/0/10)#dot1x port-control mac-based 5 Enable the voice VLAN feature on the interface console(config-if-Gi1/0/10)#voice vlan 25 710 Configuring VLANs 6 Disable authentication for the voice VLAN on the port. This step is required only if the voice phone does not support port-based authentication. console(config-if-Gi1/0/10)#voice vlan auth disable 7 Exit to Privileged Exec mode. console(config-if-Gi1/0/10)# 8 View the voice VLAN settings for port 10. console#show voice vlan interface gi1/0/10 Interface............................. Voice VLAN Interface Mode............. Voice VLAN ID......................... Voice VLAN COS Override............... Voice VLAN DSCP Value................. Voice VLAN Port Status................ Voice VLAN Authentication............. Gi1/0/10 Enabled 25 False 46 Disabled Disabled Configuring a Private VLAN 1 Configure the VLANs and their roles: This example configures VLAN 100 as the primary VLAN, secondary VLAN 101 as the community VLAN and secondary VLANs 102 and 103 as the isolated VLANs: switch# configure switch(config)# vlan 100 switch(config-vlan-100)# switch(config-vlan-100)# switch(config)# vlan 101 switch(config-vlan-101)# switch(config-vlan-101)# switch(config)# vlan 102 switch(config-vlan-102)# switch(config-vlan-102)# switch(config)# vlan 103 switch(config-vlan-103)# switch(config-vlan-103)# private-vlan primary exit private-vlan community exit private-vlan isolated exit private-vlan isolated exit 2 Associate the community and isolated VLANs with the primary VLAN. switch(config)# vlan 100 Configuring VLANs 711 switch(config-vlan-100)# private-vlan association 101-102 switch(config-vlan-100)# exit This completes the configuration of the private VLAN. The only remaining step is to assign the ports to the private VLAN. 3 Assign the router connected port to the primary VLAN: console(config)#interface te1/1/1 console(config-if-Te1/1/1)#switchport mode private-vlan promiscuous console(config-if-Te1/1/1)#switchport private-vlan mapping 100 101-102 console(config-if-Te1/1/1)#exit 4 Assign the community VLAN ports: console(config)#interface gi1/0/11 console(config-if-Gi1/0/11)#switchport mode private-vlan host console(config-if-Gi1/0/11)#switchport private-vlan hostassociation 100 101 console(config-if-Gi1/0/11)#interface gi1/0/12 console(config-if-Gi1/0/12)#switchport mode private-vlan host console(config-if-Gi1/0/12)#switchport private-vlan hostassociation 100 101 5 Assign the isolated VLAN ports: console(config)#interface gi1/0/10 console(config-if-Gi1/0/10)#switchport mode private-vlan host console(config-if-Gi1/0/10)#switchport private-vlan hostassociation 100 102 console(config-if-Gi1/0/10)#interface gi2/0/10 console(config-if-Gi2/0/10)#switchport mode private-vlan host console(config-if-Gi2/0/10)#switchport private-vlan hostassociation 100 102 console(config-if-Gi2/0/10)#interface gi2/0/11 console(config-if-Gi2/0/11)#switchport mode private-vlan host console(config-if-Gi2/0/11)#switchport private-vlan hostassociation 100 102 6 Show the configuration: console(config)#show vlan private-vlan type VLAN ---100 101 102 712 Type ----------------------primary community isolated Configuring VLANs 103 isolated console#show vlan private-vlan Primary VLAN Secondary VLAN Community ------------ -------------- ------------------100 102 101 console(config)#show vlan VLAN ----1 100 101 102 Name Ports ----------- ------------default Po1-128, Te1/1/1, Gi1/0/1-10, Gi1/0/13-24 VLAN0100 Te1/1/1, Gi1/0/11-12 VLAN0101 Gi1/0/11 VLAN0102 Gi1/0/12 Type ------------Default Static Static Static Configuring VLANs 713 714 Configuring VLANs 22 Configuring the Spanning Tree Protocol This chapter describes how to configure the Spanning Tree Protocol (STP) settings on the switch. The topics covered in this chapter include: • STP Overview • RSTP-PV • Default STP Values • Configuring Spanning Tree (Web) • Configuring Spanning Tree (CLI) • STP Configuration Examples STP Overview STP is a layer 2 protocol that provides a tree topology for switches on a bridged LAN. STP allows a network to have redundant paths without the risk of network loops. STP uses the spanning tree algorithm to provide a single path between end stations on a network. Dell Networking series switches support Classic STP, Multiple STP, and Rapid STP. What Are Classic STP, Multiple STP, and Rapid STP? Classic STP provides a single path between end stations, avoiding and eliminating loops. Multiple Spanning Tree Protocol (MSTP) supports multiple instances of Spanning Tree to efficiently channel VLAN traffic over different interfaces. Each instance of the Spanning Tree behaves in the manner specified in IEEE 802.1w, Rapid Spanning Tree (RSTP), with slight modifications in the working but not the end effect (chief among the effects, is the rapid Configuring the Spanning Tree Protocol 715 transitioning of the port to Forwarding). The difference between the RSTP and the traditional STP (IEEE 802.1d) is the ability to configure and recognize full-duplex connectivity and ports which are connected to end stations, resulting in rapid transitioning of the port to the Forwarding state and the suppression of Topology Change Notifications. MSTP is compatible with both RSTP and STP. It behaves appropriately when connected to STP and RSTP bridges. A MSTP bridge can be configured to behave entirely as a RSTP bridge or a STP bridge. How Does STP Work? The switches (bridges) that participate in the spanning tree elect a switch to be the root bridge for the spanning tree. The root bridge is the switch with the lowest bridge ID, which is computed from the unique identifier of the bridge and its configurable priority number. When two switches have an equal bridge ID value, the switch with the lowest MAC address is the root bridge. After the root bridge is elected, each switch finds the lowest-cost path to the root bridge. The port that connects the switch to the lowest-cost path is the root port on the switch. The switches in the spanning tree also determine which ports have the lowest-path cost for each segment. These ports are the designated ports. Only the root ports and designated ports are placed in a forwarding state to send and receive traffic. All other ports are put into a blocked state to prevent redundant paths that might cause loops. Both internal and external path costs can be configured. For STP, RSTP, and the MSTP CIST, only the external path costs are utilized in the lowest path cost calculation. The internal path cost is used by the MST instances. To determine the root path costs and maintain topology information, switches that participate in the spanning tree use Bridge Protocol Data Units (BPDUs) to exchange information. 716 Configuring the Spanning Tree Protocol How Does MSTP Operate in the Network? In the following diagram of a small 802.1d bridged network, STP is necessary to create an environment with full connectivity and without loops. Figure 22-1. Small Bridged Network Assume that Switch A is elected to be the Root Bridge, and Port 1 on Switch B and Switch C are calculated to be the root ports for those bridges, Port 2 on Switch B and Switch C would be placed into the Blocking state. This creates a loop-free topology. End stations in VLAN 10 can talk to other devices in VLAN 10, and end stations in VLAN 20 have a single path to communicate with other VLAN 20 devices. Configuring the Spanning Tree Protocol 717 Figure 22-2 shows the logical single STP network topology. Figure 22-2. Single STP Topology For VLAN 10 this single STP topology is fine and presents no limitations or inefficiencies. On the other hand, VLAN 20's traffic pattern is inefficient. All frames from Switch B will have to traverse a path through Switch A before arriving at Switch C. If the Port 2 on Switch B and Switch C could be used, these inefficiencies could be eliminated. MSTP does just that, by allowing the configuration of MSTIs based upon a VLAN or groups of VLANs. In this simple case, VLAN 10 could be associated with Multiple Spanning Tree Instance (MSTI)1 with an active topology similar to Figure 22-2 and VLAN 20 could be associated with MSTI 2 where Port 1 on both Switch A and Switch B begin discarding and all others forwarding. This simple modification creates an active topology with a better distribution of network traffic and an increase in available bandwidth. 718 Configuring the Spanning Tree Protocol The logical representation of the MSTP environment for these three switches is shown in Figure 22-3. Figure 22-3. Logical MSTP Environment Configuring the Spanning Tree Protocol 719 In order for MSTP to correctly establish the different MSTIs as above, some additional changes are required. For example, the configuration would have to be the same on each and every bridge. That means that Switch B would have to add VLAN 10 to its list of supported VLANs (shown in Figure 22-3 with a *). This is necessary with MSTP to allow the formation of Regions made up of all switches that exchange the same MST Configuration Identifier. It is within only these MST Regions that multiple instances can exist. It will also allow the election of Regional Root Bridges for each instance. One common and internal spanning tree (CIST) Regional Root for the CIST and an MSTI Regional Root Bridge per instance will enable the possibility of alternate paths through each Region. Above Switch A is elected as both the MSTI 1 Regional Root and the CIST Regional Root Bridge, and after adjusting the Bridge Priority on Switch C in MSTI 2, it would be elected as the MSTI 2 Regional Root. To further illustrate the full connectivity in an MSTP active topology, the following rules apply: 1 Each Bridge or LAN is in only one Region. 2 Every frame is associated with only one VID. 3 Frames are allocated either to the IST or MSTI within any given Region. 4 The internal spanning tree (IST) and each MSTI provides full and simple connectivity between all LANs and Bridges in a Region. 5 All Bridges within a Region reach a consistent agreement as to which ports interconnect that Region to a different Region and label those as Boundary Ports. 6 At the Boundary Ports, frames allocated to the CIST or MSTIs are forwarded or not forwarded alike. 7 The CIST provides full and simple connectivity between all LANs and Bridges in the network. 720 Configuring the Spanning Tree Protocol MSTP with Multiple Forwarding Paths Consider the physical topology shown in Figure 22-4. It might be assumed that MSTI 2 and MSTI 3 would follow the most direct path for VLANs 20 and 30. However, using the default path costs, this is not the case. MSTI operates without considering the VLAN membership of the ports. This results in unexpected behavior if the active topology of an MSTI depends on a port that is not a member of the VLAN assigned to the MSTI and the port is selected as root port. In this configuration, port TE 1/0/11 is selected as the root port and ports TE1/0/12 and TE1/0/13 are blocked. To resolve the issue, set the port path cost of the directly connected links to allow the MSTIs to connect directly. Figure 22-4. MSTP with Multiple Forwarding Paths Configuring the Spanning Tree Protocol 721 What are the Optional STP Features? The Dell Networking series switches support the following optional STP features: • BPDU flooding • PortFast • BPDU filtering • Root guard • Loop guard • BPDU protection BPDU Flooding The BPDU flooding feature determines the behavior of the switch when it receives a BPDU on a port that is disabled for spanning tree. If BPDU flooding is configured, the switch will flood the received BPDU to all the ports on the switch which are similarly disabled for spanning tree. Port Fast The PortFast feature reduces the STP convergence time by allowing edge ports that are connected to end devices (such as a desktop computer, printer, or file server) to transition to the forwarding state without going through the listening and learning states. BPDU Filtering Ports that have the PortFast feature enabled continue to transmit BPDUs. The BPDU filtering feature prevents PortFast-enabled ports from sending BPDUs. If BPDU filtering is configured globally on the switch, the feature is automatically enabled on all operational PortFast-enabled ports. These ports are typically connected to hosts that drop BPDUs. However, if an operational edge port receives a BPDU, the BPDU filtering feature disables PortFast and allows the port to participate in the spanning tree calculation. Enabling BPDU filtering on a specific port prevents the port from sending BPDUs and allows the port to drop any BPDUs it receives. 722 Configuring the Spanning Tree Protocol Root Guard Root guard is another way of controlling the spanning-tree topology other than setting the bridge priority or path costs. Root guard ensures that a port does not become a root port or a blocked port. When a switch is elected as the root bridge, all ports are assigned roles as designated ports unless two or more ports of the root bridge are connected in a loop. If the switch receives a superior STP BPDU on a root-guard enabled port, the root guard feature moves the port to a root-inconsistent spanning-tree state. No traffic is forwarded across the port, but it continues to receive BPDUs, discards received traffic, and is included in the active topology. Essentially, this is equivalent to the IEEE 802.1D listening state. By not transitioning the port on which the superior BPDU has been received to the forwarding state (designated role), root guard helps maintain the existing spanning-tree topology. When the STP mode is configured as MSTP, the port may be a designated port in one MSTI and an alternate port in the CIST, etc. Root guard is a per port (not a per port instance command) configuration, so all the MSTP instances this port participates in should not be expected to take on a root role. Loop Guard Loop guard protects a network from forwarding loops induced by BPDU packet loss. The reasons for failing to receive packets are numerous, including heavy traffic, software problems, incorrect configuration, and unidirectional link failure. When a non-designated port no longer receives BPDUs, the spanning tree algorithm considers the link to be loop free and transitions the link from blocking to forwarding. Once in the forwarding state, the link may create a loop in the network. Enabling loop guard prevents such accidental loops. When a port is no longer receiving BPDUs and the max age timer expires, the port is moved to a loopinconsistent blocking state. In the loop-inconsistent blocking state, traffic is not forwarded so the port behaves as if it is in the blocking state; that is, it discards received traffic, does not learn MAC addresses, and is not part of the active topology. The port will remain in this state until it receives a BPDU. It will then transition through the normal spanning tree states based on the information in the received BPDU. Configuring the Spanning Tree Protocol 723 NOTE: Loop Guard should be configured only on non-designated ports. These include ports in alternate or backup roles. Root ports and designated ports should not have loop guard enabled so that they can forward traffic. BPDU Protection When the switch is used as an access layer device, most ports function as edge ports that connect to a device such as a desktop computer or file server. The port has a single, direct connection and is configured as an edge port to implement the fast transition to a forwarding state. When the port receives a BPDU packet, the system sets it to non-edge port and recalculates the spanning tree, which causes network topology flapping. In normal cases, these ports do not receive any BPDU packets. However, someone may forge BPDU to maliciously attack the switch and cause network flapping. BPDU protection can be enabled in RSTP to prevent such attacks. When BPDU protection is enabled, the switch disables an edge port that has received BPDU and notifies the network manager about it. RSTP-PV Dell Networking switches support both Rapid Spanning Tree Per VLAN (RSTP-PV) and Spanning Tree Per VLAN (STP-PV) with a high degree of interoperability with other vendor implementations, such as Cisco's PVST+ and RPVST+. RSTP-PV is the IEEE 802.1w (RSTP) standard implemented per VLAN. A single instance of rapid spanning tree (RSTP) runs on each configured VLAN. Each RSTP instance on a VLAN has a root switch. The RSTP-PV protocol state machine, port roles, port states, and timers are similar to those defined for RSTP. RSTP-PV embeds the DRC and IndirectLink Fast Rapid Convergence (IRC) features, which cannot be disabled. STP-PV is the IEEE 802.1s (STP) standard implemented per VLAN. The STP-PV-related state machine, roles, and timers are similar to those defined for STP. STP-PV does not have the DirectLink Rapid Convergence (DRC) or IndirectLink Rapid Convergence (IRC) features enabled by default. These features can be enabled by the switch administrator. 724 Configuring the Spanning Tree Protocol The switch spanning tree configuration is global in nature. Enabling RSTPPV disables other spanning tree modes on the switch. The switch cannot operate with some ports configured to operate in standard spanning tree mode and others to operate in RSTP-PV mode. However, RSTP-PV has fallback modes for compatibility with standards-based versions of spanning tree. Access Ports—For an access port, normal IEEE BPDUs will be received and sent, though STP-PV or RSTP-PV is enabled on the switch. BPDUs received on the access port will be associated with the CST instance. Trunk Ports—If the native VLAN on an IEEE 802.1Q trunk is VLAN 1: • VLAN 1 STP BPDUs are sent to the IEEE STP MAC address (0180.c200.0000), untagged. • VLAN 1 STP BPDUs are also sent to the SSTP MAC address, untagged. • Non-VLAN 1 STP BPDUs are sent to the SSTP MAC address (also called the Shared Spanning Tree Protocol [SSTP] MAC address, 0100.0ccc.cccd), tagged with a corresponding IEEE 802.1Q VLAN tag. If the native VLAN on an IEEE 802.1Q trunk is not VLAN 1: • VLAN 1 STP BPDUs are sent to the SSTP MAC address, tagged with a corresponding IEEE 802.1Q VLAN tag. • VLAN 1 STP BPDUs are also sent to the IEEE STP MAC address on the Native VLAN of the IEEE 802.1Q trunk, untagged. • Non-VLAN 1 STP BPDUs are sent to the SSTP MAC address, tagged with a corresponding IEEE 802.1Q VLAN tag. DirectLink Rapid Convergence The DirectLink Rapid Convergence (DRC) feature is designed for an accesslayer switch that has redundant blocked uplinks. It operates on ports blocked by spanning tree. DRC can be configured for the entire switch; it cannot be enabled for individual VLANs. The DRC feature is based on the concept of an uplink group. An uplink group consists of all the ports that provide a path to the root bridge (the root port and any blocked ports). If the root port fails, the blocked port with next lowest cost from the uplink group is selected and immediately put in the forwarding state without going through the standard spanning tree listening and learning states. Configuring the Spanning Tree Protocol 725 To accelerate convergence time once DRC has switched over to a new root port, STP-PV transmits dummy packets out the new root port, with the source MAC addresses taken from its forwarding table. The destination address is an SSTP MAC address that ensures that the packet is flooded on the whole network. The packets update the forwarding tables on the other upstream switches. The rate at which the dummy multicasts are sent can be configured by the administrator. RSTP-PV has a different mechanism adopted from IEEE 802.1w that handles the update of the forwarding database and the fast transition to a new uplink. DRC can be enabled on RSTP-PV enabled switches but has no effect. DRC is disabled when the administrator modifies the spanning-tree priority of a VLAN and is re-enabled only when the default priority is restored. DRC and Link Up Events In the event of failure of the primary uplink, a replacement uplink is immediately selected from the uplink group and put into the forwarding state. If another port is enabled that, in accordance with STP rules, should become the primary uplink (root port), the switch delays migrating to the new port for twice the forwarding delay. The purpose of this delay is two-fold: • Stability—If the primary uplink is flapping, reenabling the link immediately can introduce additional instability into the network. • Reduced Traffic Loss—DRC moves a port into the forwarding state as soon as it is up, but the connected port obeys the usual STP rules; i.e. it goes through the listening and learning stages, which take 15 seconds each by default. Delaying the switchover allows the connected port to go to through the listening and learning states while the switch is still transmitting packets on the original uplink. The optimal behavior is to keep the current uplink active and hold the new port in the blocked state for twice the forwarding delay. 726 Configuring the Spanning Tree Protocol IndirectLink Rapid Convergence Feature To handle indirect link failure, the STP standard requires that a switch passively wait for “max_age” seconds once a topology change has been detected. IndirectLink Rapid Convergence (IRC) handles these failures in two phases: • Rapid detection of an indirect link failure. Tracking the inferior BPDUs that a designated bridge detects when it transmits a direct link failure indicates that a failure has occurred elsewhere in the network. • Performing an immediate check if the BPDU information stored on a port is still valid. This is implemented with a new protocol data unit (PDU) and the Root Link Query message (RLQ). Receiving an inferior BPDU on a port from the designated bridge indicates that one of the following has occurred on the designated bridge: • The path to the root has been lost and the switch starts to advertise a root with a numerically higher bridge ID (worse root) than the local switch. • The path cost to the root has increased above the path cost of the local switch. IEEE 802.1s behavior is to ignore inferior BPDUs. IRC retains the inferior BPDUs sent by the designated bridge and processes them to determine if a failure has occurred on the path to the root. In this case, it must age-out at least one port. This process occurs only in the case that a bridge in the network detects a direct link failure. The switch tracks inferior BPDUs sent by the designated bridge only, since this is the BPDU that is stored for the port. If, for instance, a newly inserted bridge starts to send inferior BPDUs, it does not start the IRC feature. Similar to DRC, the IEEE 802.1w standard incorporated the IRDC feature. RSTP-PV enabled switches allow IRC to be enabled or disabled, but ignore the setting as the RSTP-PV state machines already implement IRC. Reacting to Indirect Link Failures When an inferior BPDU is received on a non-designated port, phase 2 of IRC processing starts. An RLQ PDU is transmitted on all non-designated ports except the port where the inferior BPDU was received and self-looped ports. This action is intended to verify that the switch can still receive from the root Configuring the Spanning Tree Protocol 727 on ports that should have a path to the root. The port where the switch received the inferior BPDU is excluded because it already failed; self-looped and designated ports are eliminated as they do not have a path to the root. Figure 22-5. IRC Flow Inferior BDPU received. Are there other non-self-looped non-designated ports? No Connectivity to root is lost. Recompute spanning-tree. Yes -> Send RLQ query on non-designated ports. Negative: Root lost on this port Wait for RLQ responses. No Age-out the BPDU for this port. Have received response for every RLQ sent? No Yes Yes: Can still reach root on a port. Yes Connectivity to root still exists – age out port with inferior BPDU. Have received response for every RLQ sent? No Are all RLQ responses negative? No, end processing Upon receiving a negative RLQ response on a port, the port has lost connection to the root and the switch ages-out its BPDU. If all other nondesignated ports received a negative answer, the switch has lost the root and restarts the STP calculation. If the response confirms the switch can still access the root bridge via a particular port, it immediately ages-out the port on which the inferior BPDU was received. If the switch only received responses with a root different from the original root, it has lost the root port and restarts the STP calculation immediately. 728 Configuring the Spanning Tree Protocol Interoperability Between STP-PV and RSTP-PV Modes STP-PV is derived from 802.1D and RSTP-PV is derived from 802.1w. The fallback mechanism is the same as between a standard 802.1D switch and a standard 802.1w switch. When a lower protocol version BPDU is received on a switch that runs a higher protocol version, the latter falls back to the lower version after its migration delay timer expires. For example, an RSTP-PV switch, when connected to STP-PV switch, falls back to the STP-PV protocol after the migration delay timer expires. Interoperability With IEEE Spanning Tree Protocols When a switch configured with RSTP-PV receives IEEE standard RSTP BPDUs on a port, it responds with two versions of BPDUs on the port: SSTP formatted BPDUs and IEEE standard STP BPDUs. The IEEE standard BPDUs are processed by the peer switch running MSTP/RSTP, and the SSTP format BPDUs are flooded across the MSTP/RSTP domain. Figure 22-6. RSTP-PV and IEEE Spanning Tree Interoperability IEEE BPDUs for VLAN1 (untagged) IEEE BPDUs for VLAN1 (untagged) RSTP-PV SSTP BPDUs for VLAN1 (untagged) IEEE SSTP BPDUs for other VLANs (tagged) Common Spanning Tree There are differences between the ways that MSTP and RSTP-PV map spanning tree instances to VLANs: RSTP-PV creates a spanning tree instance for each VLAN, and MSTP maps one or more VLANs to each MST instance. Where an RSTP-PV region is connected to an MSTP region, the set of RSTPPV instances does not generally match the set of MST instances. Therefore, the RSTP-PV region and the MSTP region communicate with each other on a single common spanning tree instance. For the MSTP region, the MSTP instance communicates to the RSTP-PV region using the CIST. For the RSTP-PV region, switches use the VLAN 1 RSTP-PV instance as the common spanning tree. On the link between the Configuring the Spanning Tree Protocol 729 RSTP-PV region and the MSTP region, the RSTP-PV switch sends VLAN1 BPDUs in IEEE standard format, so they can be interpreted by the MSTP peers. Similarly, the RSTP-PV switch processes incoming MSTP BPDUs as though they were BPDUs for the VLAN 1 RSTP-PV instance. If the RSTP-PV switch ports connected to the MSTP switches are configured with a native VLAN, the RSTP-PV switches are able to detect IEEE standard format BPDUs arriving from peer switches, incorporate them into the common spanning tree that operates in the native VLAN (VLAN 1), and transmit untagged STP or RSTP packets to the STP/RSTP peers, in addition to the SSTP format BPDUs. SSTP BPDUs Flooding Across MST (CST) Regions In addition to the IEEE standard RSTP or STP BPDUs that the RSTP-PV switch sends to the MSTP (or RSTP or STP) region, the switch sends SSTP format BPDUs for VLAN 1 untagged. The MSTP switch does not interpret the SSTP BPDUs as standard BPDUs because they do not use the standard destination MAC address, so it makes no spanning tree decisions based on them. Instead, it floods the SSTP BPDUs over all ports in the corresponding VLAN. These SSTP BPDUs may be multicast over the MSTP region to other RSTP-PV switches, which use them to maintain the VLAN 1 spanning tree topology across the MSTP (non-RSTP-PV) switches. The RSTP-PV switches also send SSTP format BPDUs for the other (nonVLAN 1) RSTP-PV instances into the MSTP region, tagged with the VID of their associated VLANs. These SSTP packets are also be multicast by the switches in the MSTP region, and will reach any other RSTP-PV regions connected to the MSTP region. The switches in the remote RSTP-PV regions receive and process them as normal RSTP-PV BPDUs. Thus, RSTP-PV instances are transparently expanded across the MSTP region and their spanning trees span the MSTP region. For RSTP-PV, the MSTP region is treated as a single hub. Interoperability with RSTP In Figure 22-7: 730 • SW1 and SW2 are Dell Networking switches running RSTP-PV with default bridge priority 32768. • SW3 is a Dell Networking switch running RSTP with default bridge priority 32768. Configuring the Spanning Tree Protocol Figure 22-7. RSTP-PV and RSTP Interoperability Root for VLAN2 and 3 1/0/1 1/0/1 SW1 SW2 1/0/1 1/0/2 1/0/3 1/0/4 VLAN1 VLAN2 VLAN3 SW3 Root for VLAN1 SW3 sends IEEE STP BPDUs to the IEEE multicast MAC address as untagged frames. These BPDUs are processed by the VLAN 1 STP instance on the RSTP-PV switch as part of the VLAN 1 STP instance. The RSTP-PV side sends IEEE STP BPDUs corresponding to the VLAN 1 STP to the IEEE MAC address as untagged frames across the link. At the same time, SSTP BPDUs are sent as untagged frames. IEEE switches simply flood the SSTP BPDUs throughout VLAN 1. This facilitates RSTP-PV connectivity in case there are other RSTP-PV switches connected to the IEEE STP domain. For non-native VLANs (VLANs 2–4093), the RSTP-PV switch sends SSTP BPDUs, tagged with their VLAN number. The VLAN STP instances are multicast across the RSTP region, as if it were a hub switch. Configuring the Spanning Tree Protocol 731 The VLAN 1 STP instance of SW1 and SW2 are joined with the STP instance running in SW3. VLANs 2 and 3 consider the path across SW3 as another segment linking SW1 and SW2, and their SSTP information is multicast across SW3. The bridge priority of SW1 and SW2 for VLAN1 instance is 32769 (bridge priority + VLAN identifier). The bridge priority of SW3 is 32768, per the IEEE 802.w standard. SW3 is selected as Root Bridge for the VLAN1 instance that is CST, and SW1 is selected as Root Bridge for VLAN2 and VLAN3 (based on the low MAC address of SW1). Interoperability with MSTP RSTP-PV runs an individual RSTP instance for each VLAN. MSTP maps VLANs to MSTIs, so one-to-one mapping between VLAN and STP instance is not possible. MSTP runs multiple MSTIs inside a region and maps them to the CIST on the border ports. The interoperability model must ensure that internal MSTIs are aware of changes to any of the RSTP-PV trees. Therefore, the simplest way to ensure the correct behavior is to join ALL RSTP-PV trees to the CST. Connecting RSTP-PV trees to the CST ensures that changes in any of the RSTP-PV STP instances will affect the CST and all MSTIs. This approach ensures that no changes go unnoticed and no black holes occur in a single VLAN. As with IEEE STP, every tree in the RSTP-PV domain views the MSTP regions as virtual bridges with multiple boundary ports. A topology change in any of RSTP-PV trees will affect the CST and propogate through every MSTI instance in all MSTP regions. This behavior, consequently, makes the MSTP topology less stable. The MSTP implementation simulates RSTP-PV by replicating CIST BPDUs on the link facing the RSTP-PV domain and sending those BPDUs on ALL VLANs active on the trunk. The MSTP switch processes IEEE STP VLAN 1 BPDUs received from the RSTP-PV domain using the CIST instance. The RSTP-PV+ domain interprets the MSTP domain as an RSTP-PV bridge with all per-VLAN instances claiming the CIST Root as the root of their individual spanning tree. For the common STP Root elected between MSTP and RSTPPV, two options are possible: 732 Configuring the Spanning Tree Protocol The MSTP domain contains the root bridge for ALL VLANs. This implies that the CIST Root Bridge ID is configured to be better than any RSTPPV STP root Bridge ID. If there is only one MSTP region connected to the RSTP-PV domain, then all boundary ports on the virtual-bridge will be unblocked and used by RSTP-PV. This is the only supported topology, as the administrator can manipulate uplink costs on the RSTP-PV side and obtain optimal traffic engineering results. In Figure 22-8, VLANs 2 and 3 have their STP costs configured to select different uplinks connected to the MSTP region's boundary ports. Since the CIST Root is inside the MSTP region, both boundary ports are non-blocking designated and the load balancing scheme operates as expected. Figure 22-8. MSTP and RSTP-PV Interoperability CIST Root MSTP Region Boundary Port 1 Boundary Port 2 VLAN 2 STP × VLAN 3 STP × • PVST+ Bridge Configuring the Spanning Tree Protocol 733 • The alternative is that the RSTP-PV domain contains the root bridges for ALL VLANs. This is only true if all RSTP-PV root bridges’ Bridge IDs for all VLANs are better than the MSTP CIST Root Bridge ID. This is not a supported topology, because all MSTIs map to CIST on the border link, and it is not possible to load-balance the MSTIs as they enter the RSTPPV domain. The Dell Networking RSTP-PV implementation does not support the second option. The MSTP domain must contain the bridge with the best Bridge ID to ensure that the CIST Root is also the root for all RSTP-PV trees. In any other case, the MSTP border switch will place the ports that receive superior BPDUs from the RSTP-PV region in the root-inconsistent state. To resolve this issue, ensure that the RSTP-PV domain does not have any bridges with Bridge IDs better than the CIST Root Bridge ID. Native VLAN Inconsistent State This occurs if a trunk port receives an untagged SSTP BPDU with a VLAN type, length, value (TLV) that does not match the VLAN where the BPDU was received. In this case, the port transitions to the blocked state. Configuration Examples See "RSTP-PV Access Switch Configuration Example" on page 756. 734 Configuring the Spanning Tree Protocol Default STP Values Spanning tree is globally enabled on the switch and on all ports and LAGs. Table 22-1 summarizes the default values for STP. Table 22-1. STP Defaults Parameter Default Value Enable state Enabled (globally and on all ports) Spanning tree mode RSTP (Classic STP, STP-PV, RSTP-PV and MSTP are disabled) Switch priority 32768 BPDU flooding Disabled PortFast mode Disabled PortFast BPDU filter Disabled Loop guard Disabled BPDU protection Disabled Spanning tree port priority 128 Maximum-aging time 20 seconds Forward-delay time 15 seconds Maximum hops 20 Spanning tree transmit hold count 6 MSTP region name MAC address of switch MSTP included VLANs 1 Configuring the Spanning Tree Protocol 735 Configuring Spanning Tree (Web) This section provides information about the OpenManage Switch Administrator pages for configuring and monitoring STP settings on a Dell Networking N2000, N3000, and N4000 series switches. For details about the fields on a page, click at the top of the page. STP Global Settings The STP Global Settings page contains fields for enabling STP on the switch. To display the STP Global Settings page, click Switching → Spanning Tree → Global Settings in the navigation panel. 736 Configuring the Spanning Tree Protocol Figure 22-9. Spanning Tree Global Settings Configuring the Spanning Tree Protocol 737 STP Port Settings Use the STP Port Settings page to assign STP properties to individual ports. To display the STP Port Settings page, click Switching → Spanning Tree → STP Port Settings in the navigation panel. Figure 22-10. 738 STP Port Settings Configuring the Spanning Tree Protocol Configuring STP Settings for Multiple Ports To configure STP settings for multiple ports: 1 Open the STP Port Settings page. 2 Click Show All to display the STP Port Table. Figure 22-11. Configure STP Port Settings 3 For each port to configure, select the check box in the Edit column in the row associated with the port. 4 Select the desired settings. 5 Click Apply. Configuring the Spanning Tree Protocol 739 STP LAG Settings Use the STP LAG Settings page to assign STP aggregating ports parameters. To display the STP LAG Settings page, click Switching → Spanning Tree → STP LAG Settings in the navigation panel. Figure 22-12. STP LAG Settings Configuring STP Settings for Multiple LAGs To configure STP settings on multiple LAGS: 1 Open the STP LAG Settings page. 2 Click Show All to display the STP LAG Table. 740 Configuring the Spanning Tree Protocol Figure 22-13. Configure STP LAG Settings 3 For each LAG to configure, select the check box in the Edit column in the row associated with the LAG. 4 Select the desired settings. 5 Click Apply. Rapid Spanning Tree Rapid Spanning Tree Protocol (RSTP) detects and uses network topologies that allow a faster convergence of the spanning tree without creating forwarding loops. To display the Rapid Spanning Tree page, click Switching → Spanning Tree → Rapid Spanning Tree in the navigation panel. Figure 22-14. Rapid Spanning Tree Configuring the Spanning Tree Protocol 741 To view RSTP Settings for all interfaces, click the Show All link. The Rapid Spanning Tree Table displays. Figure 22-15. 742 RSTP Settings Configuring the Spanning Tree Protocol MSTP Settings The Multiple Spanning Tree Protocol (MSTP) supports multiple instances of Spanning Tree to efficiently channel VLAN traffic over different interfaces. MSTP is compatible with both RSTP and STP; a MSTP bridge can be configured to behave entirely as a RSTP bridge or a STP bridge. To display the MSTP Settings page, click Switching → Spanning Tree → MSTP Settings in the navigation panel. Figure 22-16. MSTP Settings Configuring the Spanning Tree Protocol 743 Viewing and Modifying the Instance ID for Multiple VLANs To configure MSTP settings for multiple VLANS: 1 Open the MSTP Settings page. 2 Click Show All to display the MSTP Settings Table. Figure 22-17. Configure MSTP Settings 3 For each Instance ID to modify, select the check box in the Edit column in the row associated with the VLAN. 4 Update the Instance ID settings for the selected VLANs. 5 Click Apply. 744 Configuring the Spanning Tree Protocol MSTP Interface Settings Use the MSTP Interface Settings page to assign MSTP settings to specific interfaces. To display the MSTP Interface Settings page, click Switching → Spanning Tree → MSTP Interface Settings in the navigation panel. Figure 22-18. MSTP Interface Settings Configuring MSTP Settings for Multiple Interfaces To configure MSTP settings for multiple interfaces: 1 Open the MSTP Interface Settings page. 2 Click Show All to display the MSTP Interface Table. 3 For each interface to configure, select the check box in the Edit column in the row associated with the interface. 4 Update the desired settings. 5 Click Apply. Configuring the Spanning Tree Protocol 745 Configuring Spanning Tree (CLI) This section provides information about the commands you use to configure STP settings on the switch. For more information about the commands, see the Dell Networking N2000, N3000, and N4000 Series Switches CLI Reference Guide at support.dell.com/manuals. Configuring Global STP Bridge Settings Beginning in Privileged EXEC mode, use the following commands to configure the global STP settings for the switch, such as the priority and timers. Command Purpose configure Enter global configuration mode. spanning-tree Enable spanning tree on the switch. spanning tree mode {stp Specify which spanning tree mode to use on the switch. | rstp |mst} spanning-tree priority Specify the priority of the bridge. (Range: 0–61440). The switch with the lowest priority value is elected as the root switch. spanning-tree max-age Specify the switch maximum age time, which indicates the amount of time in seconds a bridge waits before implementing a topological change. Valid values are from (6 to 40) seconds. spanning-tree forwardtime seconds Specify the switch forward delay time, which indicates the amount of time in seconds a bridge remains in a listening and learning state before forwarding packets. Valid values are from (4 to 30) seconds. priority seconds spanning-tree max-hops Configure the maximum number of hops for the Spanning tree. Valid values are from (6 to 40). hops spanning-tree transmit hold-count [value] Set the maximum number of BPDUs that a bridge is allowed to send within a hello time window (2 seconds). The range for value is 1–10. CTRL + Z Exit to Privileged EXEC mode. 746 Configuring the Spanning Tree Protocol Command Purpose show spanning-tree [detail] [active | blockedports] View information about spanning tree and the spanning tree configuration on the switch. Configuring Optional STP Features Beginning in Privileged EXEC mode, use the following commands to configure the optional STP features on the switch or on specific interfaces. Command Purpose configure Enter global configuration mode. spanning-tree bpdu flooding Allow the flooding of BPDUs received on non-spanningtree ports to all other non-spanning-tree ports. spanning-tree portfast Enable PortFast on all switch ports. spanning-tree portfast bpdufilter default Prevent ports configured in PortFast mode from sending BPDUs. spanning-tree loopguard Enable loop guard on all ports. default spanning-tree bpduprotection Enable BPDU protection on the switch. interface interface Enter interface configuration mode for the specified interface. The interface variable includes the interface type and number, for example tengigabitethernet 1/0/3 or portchannel 4. You can also specify a range of interfaces with the interface range command, for example, interface range tengigabitethernet 1/0/8-12 configures interfaces 8, 9, 10, 11, and 12. The range keyword is also valid for LAGs (portchannels). spanning-tree autoportfast Set the port to auto portfast mode. This enables the port to become a portfast port if it does not see any BPDUs for 3 seconds. spanning-tree guard {root | loop | none} Enable loop guard or root guard (or disable both) on the interface. Configuring the Spanning Tree Protocol 747 Command Purpose spanning-tree tcnguard Prevent the port from propagating topology change notifications. CTRL + Z Exit to Privileged EXEC mode. show spanning-tree summary View various spanning tree settings and parameters for the switch. Configuring STP Interface Settings Beginning in Privileged EXEC mode, use the following commands to configure the STP settings for a specific interface. Command Purpose configure Enter global configuration mode. interface interface Enter interface configuration mode for the specified interface. The interface variable includes the interface type and number, for example tengigabitethernet 1/0/3 or portchannel 4. You can also specify a range of interfaces with the interface range command, for example, interface range tengigabitethernet 1/0/8-12 configures interfaces 8, 9, 10, 11, and 12. The range keyword is also valid for LAGs (portchannels). spanning-tree disable Disable spanning tree on the port. spanning-tree portpriority priority Specify the priority of the port. (Range: 0–240). spanning-tree cost cost Specify the spanning tree path cost for the port. (Range: 0–200,000,000). The default cost is 0, which signifies that the cost is automatically calculated based on port speed. CTRL + Z Exit to Privileged EXEC mode. show spanning-tree View spanning tree configuration information for the specified port or LAG (port-channel). interface 748 The priority value is used to determine which ports are put in the forwarding state and which ports are put in the blocking state. A port with a lower priority value is more likely to be put into a forwarding state. Configuring the Spanning Tree Protocol Configuring MSTP Switch Settings Beginning in Privileged EXEC mode, use the following commands to configure MSTP settings for the switch. Command Purpose configure Enter global configuration mode. spanning-tree mst configuration Enable configuring an MST region by entering the multiple spanning tree (MST) mode. name string Define the MST configuration name revision version Identify the MST configuration revision number. instance instance-id {add | remove} vlan Map VLANs to an MST instance. vlan-range • instance-ID — ID of the MST instance. (Range: 1-4094) • vlan-range — VLANs to be added to the existing MST instance. To specify a range of VLANs, use a hyphen. To specify a series of VLANs, use a comma. (Range: 1-4093) exit Return to global configuration mode. spanning-tree mst instance-id priority Set the switch priority for the specified spanning tree instance. priority • instance-id — ID of the spanning tree instance. (Range: 1-4094) • priority — Sets the switch priority for the specified spanning tree instance. This setting affects the likelihood that the switch is selected as the root switch. A lower value increases the probability that the switch is selected as the root switch. (Range: 0-61440) CTRL + Z Exit to Privileged EXEC mode. show spanning-tree mst- View multiple spanning tree configuration information. configuration show spanning-tree instance instance-id View information about the specified MSTI. Configuring the Spanning Tree Protocol 749 Configuring MSTP Interface Settings Beginning in Privileged EXEC mode, use the following commands to configure MSTP settings for the switch. Command Purpose configure Enter global configuration mode. interface interface Enter interface configuration mode for the specified interface. The interface variable includes the interface type and number, for example tengigabitethernet 1/0/3 or port-channel 4. You can also specify a range of interfaces with the interface range command, for example, interface range tengigabitethernet 1/0/8-12 configures interfaces 8, 9, 10, 11, and 12. The range keyword is also valid for LAGs (portchannels). spanning-tree mst 0 Set the external cost for the common spanning tree. (Range: 0–200000000) external-cost cost spanning-tree mst Configure the path cost for MST calculations. If a loop occurs, instance-id cost cost the spanning tree considers path cost when selecting an interface to put in the forwarding state. • instance-ID — ID of the spanning -tree instance. (Range: 14094) • cost — The port path cost. (Range: 0–200,000,000) spanning-tree mst instance-id portpriority priority Specify the priority of the port. The priority value is used to determine which ports are put in the forwarding state and which ports are put in the blocking state. A port with a lower priority value is more likely to be put into a forwarding state. • instance-ID — ID of the spanning tree instance. (Range: 14094) • priority — The port priority. (Range: 0–240 in multiples of 16) CTRL + Z Exit to Privileged EXEC mode. show spanning-tree interface instance View MST configuration information for the specified port or LAG (port-channel) and instance. instance-id 750 Configuring the Spanning Tree Protocol STP Configuration Examples This section contains the following examples: • STP Configuration Example • MSTP Configuration Example • RSTP-PV Access Switch Configuration Example STP Configuration Example This example shows a LAN with four switches. On each switch, ports 1, 2, and 3 connect to other switches, and ports 4–20 connect to hosts (in Figure 22-19, each PC represents 17 host systems). Configuring the Spanning Tree Protocol 751 Figure 22-19. STP Example Network Diagram Of the four switches in Figure 22-19, the administrator decides that Switch A is the most centrally located in the network and is the least likely to be moved or redeployed. For these reasons, the administrator selects it as the root bridge for the spanning tree. The administrator configures Switch A with the highest priority and uses the default priority values for Switch B, Switch C, and Switch D. For all switches, the administrator also configures ports 4–17 in Port Fast mode because these ports are connected to hosts and can transition directly to the Forwarding state to speed up the connection time between the hosts and the network. 752 Configuring the Spanning Tree Protocol The administrator also configures Port Fast BPDU filtering and Loop Guard to extend STP’s capability to prevent network loops. For all other STP settings, the administrator uses the default STP values. To configure the switch: 1 Connect to Switch A and configure the priority to be higher (a lower value) than the other switches, which use the default value of 32768. console#config console(config)#spanning-tree priority 8192 2 Configure ports 4–20 to be in Port Fast mode. console(config)#interface range gi1/0/4-20 console(config-if)#spanning-tree portfast console(config-if)#exit 3 Enable Loop Guard on ports 1–3 to help prevent network loops that might be caused if a port quits receiving BPDUs. console(config)#interface range gi1/0/1-3 console(config-if)#spanning-tree guard loop console(config-if)#exit 4 Enable Port Fast BPDU Filter. This feature is configured globally, but it affects only Port Fast-enabled access ports. console(config)#spanning-tree portfast bpdufilter default 5 Repeat step 2 through step 4 on Switch B, Switch C, and Switch D to complete the configuration. MSTP Configuration Example This example shows how to configure IEEE 802.1s Multiple Spanning Tree (MST) protocol on the switches shown in Figure 22-20. Configuring the Spanning Tree Protocol 753 Figure 22-20. MSTP Configuration Example To make multiple switches be part of the same MSTP region, make sure the STP operational mode for all switches is MSTP. Also, make sure the MST region name and revision level are the same for all switches in the region. To configure the switches: 1 Create VLAN 10 (Switch A and Switch B) and VLAN 20 (all switches). NOTE: Even Switch B does not have any ports that are members of VLAN 10, this VLAN must be created to allow the formation of MST regions made up of all bridges that exchange the same MST Configuration Identifier. It is only within these MST Regions that multiple instances can exist. console#configure console(config)#vlan 10,20 console(config-vlan10,20)#exit console(config-vlan)#exit 2 Set the STP operational mode to MSTP. console(config)#spanning-tree mode mst 3 Create MST instance 10 and associate it to VLAN 10. console(config)#spanning-tree mst configuration 754 Configuring the Spanning Tree Protocol console(config-mst)#instance 10 add vlan 10 4 Create MST instances 20 and associate it to VLAN 20. console(config-mst)#instance 20 add vlan 20 5 Change the region name so that all the bridges that want to be part of the same region can form the region. console(config-mst)#name dell console(config-mst)#exit 6 (Switch A only) Configure Switch A to be the root bridge of the spanning tree (CIST Regional Root) by configuring a higher root bridge priority. console(config)#spanning-tree priority 8192 7 (Switch A only) Make Switch A the Regional Root for MSTI 1 by configuring a higher priority for MST ID 10. console(config)#spanning-tree mst 10 priority 12288 8 (Switch A only) Change the priority of MST ID 20 to ensure Switch C is the Regional Root bridge for this MSTI. console(config)#spanning-tree mst 20 priority 61440 console(config)#spanning-tree priority 8192 9 (Switch C only) Change the priority of port 1 to force it to be the root port for MST 20. console(config)#interface gi1/0/1 console(config-if-Gi1/0/1)#spanning-tree mst 20 port-priority 64 console(config-if-Gi1/0/1)#exit Configuring the Spanning Tree Protocol 755 RSTP-PV Access Switch Configuration Example In this configuration, all 1G ports are presumed to be connected to host machines, and the two 10G uplink ports are connected to an aggregationlayer switch with a total L2 network diameter of 4. The aggregation-layer switch can be a single switch or multiple switches, running either RSTP-PV or MSTP. For fastest convergence during failover scenarios, it is recommended that the uplink switches be configured in RSTP-PV mode. Three VLANs are configured in addition to VLAN 1. Te1/0/1 is configured to be the primary uplink port and Te1/0/2 is configured to be the backup uplink. 1 Configure VLANs 2 through 4 and return to Global Config mode. console#configure console(config)#vlan 2-4 console(config-vlan2-4)#exit 2 Enable RSTP-PV. console(config)#spanning-tree mode rapid-pvst 3 Configure for a maximum network diameter of 4. console(config)#spanning-tree vlan 1-4 max-age 16 4 Configure access and trunk ports console(config)#interface range gi1/0/1-48 console(config-if)#switchport mode access console(config-if)exit console(config)#interface range te1/0/1-2 console(config-if)#switchport mode trunk console(config-if)#exit 5 Configure interface te1/0/1 as the preferred uplink. console(config)#interface te1/0/1 console(config-if)#spanning-tree port-priority 112 console(config-if)#exit 6 Assign ports to VLANs. console(config)#interface range gi1/0/1-12 console(config-if)#switchport access vlan 1 console(config-if)#exit console(config)#interface range gi1/0/1-12 console(config-if)#switchport access vlan 2 756 Configuring the Spanning Tree Protocol console(config-if)#exit console(config)#interface range gi1/0/1-12 console(config-if)#switchport access vlan 3 console(config-if)#exit console(config)#interface range gi1/0/1-12 console(config-if)#switchport access vlan 4 console(config-if)#exit Configuring the Spanning Tree Protocol 757 RSTP-PV Aggregation Layer Switch Configuration Example In this configuration example, two aggregation-layer switches are configured. Ports 1–4 are configured in a LAG connecting the two aggregation-layer switches. Ports 12–24 are configured as down-links to twelve access layer switches configured as in the previous example. Down-links to the accesslayer switches have physical diversity; there is one downlink to each of the twelve access-layer switches from each of the paired aggregation-layer switches. The uplink ports to the network core are configured as LAGs to provide link redundancy. It is presumed that the core links connect to a router running RSTP-PV. The configuration for the two aggregation-layer switches is identical, except for the diversity configuration noted below. For forwarding diversity, the even numbered switch is made the root for the even-numbered VLANs. The odd numbered switch is made the root for the odd-numbered VLANs. 1 Create VLANs 2 through 4: console#configure console(config)#vlan 2-4 console(config-vlan2-4)#exit 2 Enable RSTP-PV: console(config)#spanning-tree mode rapid-pvst 3 Configure for a max network diameter of 4: console(config)#spanning-tree vlan 1-4 max-age 16 4 Configure one downlink trunk port per downlink switch: console(config)#interface range te1/0/12-24 console(config-if-Te1/0/12-24)#switchport mode trunk exit 5 Configure forwarding diversity for the even numbered switches: console(config)#spanning-tree vlan 2,4 root primary console(config)#spanning-tree vlan 1,3 root secondary 6 Configure forwarding diversity for the odd numbered switches: 758 Configuring the Spanning Tree Protocol console(config)#spanning-tree vlan 1,3 root primary console(config)#spanning-tree vlan 2,4 root secondary 7 Configure two uplink ports per uplink switch: console(config)#interface range fo1/0/1-2 console(config-if-fo1/0/1-2)#channel-group 1 mode active console(config-if-fo1/0/1-2)#exit 8 Configure peer switch links: console(config)#interface range te1/0/1-4 console(config-if-te1/0/1-4)#channel-group 2 mode active console(config-if-te1/0/1-4)#exit 9 Configure the uplinks into a port channel: console(config)#interface port-channel 1 console(config-if-port-channel 1)#switchport mode trunk console(config-if-port-channel 1)#exit 10 Configure the peer links into a port channel and prefer to go to the core router or access switches directly, i.e. block the peer link unless it is needed: console(config)#interface port-channel 1 console(config-if-port-channel 1)#switchport mode trunk console(config-if-port-channel 1)#spanning-tree port-priority 144 console(config-if-port-channel 1)#exit Configuring the Spanning Tree Protocol 759 760 Configuring the Spanning Tree Protocol 23 Discovering Network Devices This chapter describes the Industry Standard Discovery Protocol (ISDP) feature and the Link Layer Discovery Protocol (LLDP) feature, including LLDP for Media Endpoint Devices (LLDP-MED). The topics covered in this chapter include: • Device Discovery Overview • Default IDSP and LLDP Values • Configuring ISDP and LLDP (Web) • Configuring ISDP and LLDP (CLI) • Device Discovery Configuration Examples Device Discovery Overview The switch software includes two different device discovery protocols: IDSP and LLDP. These protocols allow the switch to broadcast information about itself and to learn information about neighboring devices. What Is ISDP? The Industry Standard Discovery Protocol (ISDP) is a proprietary Layer 2 network protocol that inter-operates with Cisco devices running the Cisco Discovery Protocol (CDP). ISDP is used to share information between neighboring devices. The switch software participates in the CDP protocol and is able to both discover and be discovered by other CDP-supporting devices. What is LLDP? LLDP is a standardized discovery protocol defined by IEEE 802.1AB. It allows stations residing on an 802 LAN to advertise major capabilities physical descriptions, and management information to physically adjacent devices allowing a network management system (NMS) to access and display this information. Discovering Network Devices 761 LLDP is a one-way protocol; there are no request/response sequences. Information is advertised by stations implementing the transmit function, and is received and processed by stations implementing the receive function. The transmit and receive functions can be enabled/disabled separately on each switch port. What is LLDP-MED? LLDP-MED is an extension of the LLDP standard. LLDP-MED uses LLDP's organizationally-specific Type- Length-Value (TLV) extensions and defines new TLVs that make it easier for a VoIP deployment in a wired or wireless LAN/MAN environment. It also makes mandatory a few optional TLVs from LLDP and recommends not transmitting some TLVs. The TLVs only communicate information; these TLVs do not automatically translate into configuration. An external application may query the MED MIB and take management actions in configuring functionality. Why are Device Discovery Protocols Needed? The device discovery protocols are used primarily in conjunction with network management tools to provide information about network topology and configuration, and to help troubleshoot problems that occur on the network. The discovery protocols can also facilitate inventory management within a company. LLDP and the LLDP-MED extension are vendor-neutral discovery protocols that can discover devices made by numerous vendors. LLDP-MED is intended to be used on ports that connect to VoIP phones. Additional applications for LLDP-MED include device location (including for Emergency Call Service/E911) and Power over Ethernet management. ISDP interoperates with the Cisco-proprietary CDP protocol and is most effective in an environment that contains many Cisco devices. 762 Discovering Network Devices Default IDSP and LLDP Values ISDP and LLDP are globally enabled on the switch and enabled on all ports by default. By default, the switch transmits and receives LLDP information on all ports. LLDP-MED is disabled on all ports. Table 23-1 summarizes the default values for ISDP. Table 23-1. ISDP Defaults Parameter Default Value ISDP Mode Enabled (globally and on all ports) ISDPv2 Mode Enabled (globally and on all ports) Message Interval 30 seconds Hold Time Interval 180 seconds Device ID none Device ID Format Capability Serial Number, Host Name Device ID Format Serial Number Table 23-2 summarizes the default values for LLDP. Table 23-2. LLDP Defaults Parameter Default Value Transmit Mode Enabled on all ports Receive Mode Enabled on all ports Transmit Interval 30 seconds Hold Multiplier 4 Reinitialization Delay 2 seconds Notification Interval 5 seconds Transmit Management Information Disabled Notification Mode Disabled Included TLVs None Discovering Network Devices 763 Table 23-3 summarizes the default values for LLDP-MED. Table 23-3. LLDP-MED Defaults Parameter Default Value LLDP-MED Mode Disabled on all ports Config Notification Mode Disabled on all ports Transmit TVLs MED Capabilities Network Policy 764 Discovering Network Devices Configuring ISDP and LLDP (Web) This section provides information about the OpenManage Switch Administrator pages for configuring and monitoring IDSP and LLDP/LLDPMED on a Dell Networking N2000, N3000, and N4000 series switches. For details about the fields on a page, click at the top of the page. ISDP Global Configuration From the ISDP Global Configuration page, you can configure the ISDP settings for the switch, such as the administrative mode. To access the ISDP Global Configuration page, click System → ISDP → Global Configuration in the navigation panel. Figure 23-1. ISDP Global Configuration Discovering Network Devices 765 ISDP Cache Table From the ISDP Neighbor Table page, you can view information about other devices the switch has discovered through the ISDP. To access the ISDP Neighbor Table page, click System → ISDP → Neighbor Table in the navigation panel. Figure 23-2. ISDP Neighbor Table 766 Discovering Network Devices ISDP Interface Configuration From the ISDP Interface Configuration page, you can configure the ISDP settings for each interface. If ISDP is enabled on an interface, it must also be enabled globally in order for the interface to transmit ISDP packets. If the ISDP mode on the ISDP Global Configuration page is disabled, the interface will not transmit ISDP packets, regardless of the mode configured on the interface. To access the ISDP Interface Configuration page, click System → ISDP → Interface Configuration in the navigation panel. Figure 23-3. ISDP Interface Configuration To view view the ISDP mode for multiple interfaces, click Show All. Figure 23-4. ISDP Interface Summary Discovering Network Devices 767 ISDP Statistics From the ISDP Statistics page, you can view information about the ISDP packets sent and received by the switch. To access the ISDP Statistics page, click System → ISDP → Statistics in the navigation panel. Figure 23-5. ISDP Statistics 768 Discovering Network Devices LLDP Configuration Use the LLDP Configuration page to specify LLDP parameters. Parameters that affect the entire system as well as those for a specific interface can be specified here. To display the LLDP Configuration page, click Switching → LLDP → Configuration in the navigation panel. Figure 23-6. LLDP Configuration Discovering Network Devices 769 To view the LLDP Interface Settings Table, click Show All. From the LLDP Interface Settings Table page, you can view and edit information about the LLDP settings for multiple interfaces. Figure 23-7. LLDP Interface Settings Table 770 Discovering Network Devices LLDP Statistics Use the LLDP Statistics page to view LLPD-related statistics. To display the LLDP Statistics page, click Switching → LLDP → Statistics in the navigation panel. Figure 23-8. LLDP Statistics Discovering Network Devices 771 LLDP Connections Use the LLDP Connections page to view the list of ports with LLDP enabled. Basic connection details are displayed. To display the LLDP Connections page, click Switching → LLDP → Connections in the navigation panel. Figure 23-9. LLDP Connections 772 Discovering Network Devices To view additional information about a device connected to a port that has been discovered through LLDP, click the port number in the Local Interface table (it is a hyperlink), or click Details and select the port with the connected device. Figure 23-10. LLDP Connection Detail Discovering Network Devices 773 LLDP-MED Global Configuration Use the LLDP-MED Global Configuration page to change or view the LLDP-MED parameters that affect the entire system. To display the LLDP-MED Global Configuration page, click Switching→ LLDP → LLDP-MED → Global Configuration in the navigation panel. Figure 23-11. 774 LLDP-MED Global Configuration Discovering Network Devices LLDP-MED Interface Configuration Use the LLDP-MED Interface Configuration page to specify LLDP-MED parameters that affect a specific interface. To display the LLDP-MED Interface Configuration page, click Switching → LLDP → LLDP-MED → Interface Configuration in the navigation panel. Figure 23-12. LLDP-MED Interface Configuration To view the LLDP-MED Interface Summary table, click Show All. Figure 23-13. LLDP-MED Interface Summary Discovering Network Devices 775 LLDP-MED Local Device Information Use the LLDP-MED Local Device Information page to view the advertised LLDP local data for each port. To display the LLDP-MED Local Device Information page, click Switching→ LLDP→ LLDP-MED→ Local Device Information in the navigation panel. Figure 23-14. LLDP-MED Local Device Information LLDP-MED Remote Device Information Use the LLDP-MED Remote Device Information page to view the advertised LLDP data advertised by remote devices. To display the LLDP-MED Remote Device Information page, click Switching→ LLDP→ LLDP-MED→ Remote Device Information in the navigation panel. Figure 23-15. 776 LLDP-MED Remote Device Information Discovering Network Devices Configuring ISDP and LLDP (CLI) This section provides information about the commands you use to manage and view the device discovery protocol features on the switch. For more information about these commands, see the Dell Networking N2000, N3000, and N4000 Series Switches CLI Reference Guide at support.dell.com/manuals. Configuring Global ISDP Settings Beginning in Privileged EXEC mode, use the following commands to configure ISDP settings that affect the entire switch. Command Purpose configure Enter Global Configuration mode. isdp enable Administratively enable ISDP on the switch. isdp advertise-v2 Allow the switch to send ISDPv2 packets. isdp holdtime time Specify the number of seconds the device that receives ISDP packets from the switch should store information sent in the ISDP packet before discarding it. isdp timer time Specify the number of seconds to wait between sending new ISDP packets. exit Exit to Privileged EXEC mode. show isdp View global ISDP settings. Discovering Network Devices 777 Enabling ISDP on a Port Beginning in Privileged EXEC mode, use the following commands to enable ISDP on a port. Command Purpose configure Enter Global Configuration mode. interface interface Enter interface configuration mode for the specified interface. isdp enable Administratively enable ISDP on the switch. exit Exit to Global Config mode. exit Exit to Privileged Exec mode. show isdp interface all View the ISDP mode on all interfaces. Viewing and Clearing ISDP Information Beginning in Privileged EXEC mode, use the following commands to view and clear the contents of the ISDP table and to view and clear ISDP statistics. Command Purpose deviceid} show isdp entry {all | View information about all entries or a specific entry in the ISDP table. show isdp neighbors View the neighboring devices discovered through ISDP. clear isdp table Clear all entries, including discovered neighbors, from the ISDP table. show isdp traffic View ISDP statistics. clear isdp counters Reset all ISDP statistics to zero. 778 Discovering Network Devices Configuring Global LLDP Settings Beginning in Privileged EXEC mode, use the following commands to configure LLDP settings that affect the entire switch. Command Purpose configure Enter Global Configuration mode. lldp notificationinterval interval Specify how often, in seconds, the switch should send remote data change notifications. lldp timers [interval Configure the timing for local data transmission on ports transmit-interval] [hold enabled for LLDP. hold-value] [reinit reinit- • transmit-interval — The interval in seconds at which to delay] transmit local data LLDP PDUs. (Range: 5–32768 seconds) • hold-value — Multiplier on the transmit interval used to set the TTL in local data LLDP PDUs. (Range: 2–10) • reinit-delay — The delay in seconds before reinitialization. (Range: 1–10 seconds) exit Exit to Privileged EXEC mode. show lldp View global LLDP settings. Configuring Port-based LLDP Settings Beginning in Privileged EXEC mode, use the following commands to configure per-port LLDP settings. Command Purpose configure Enter Global Configuration mode. interface interface Enter interface configuration mode for the specified Ethernet interface. lldp transmit Enable the LLDP advertise (transmit) capability. lldp receive Enable the LLDP receive capability so that the switch can receive LLDP Protocol Data Units (LLDP PDUs) from other devices. lldp transmit-mgmt Include the transmission of local system management address information in the LLDP PDUs. Discovering Network Devices 779 Command Purpose lldp notification Enable remote data change notifications on the interface. lldp transmit-tlv [sysdesc][sys-name][syscap][port-desc] Specify which optional type-length-value settings (TLVs) in the 802.1AB basic management set will be transmitted in the LLDP PDUs. • sys-name — Transmits the system name TLV • sys-desc — Transmits the system description TLV • sys-cap — Transmits the system capabilities TLV • port desc — Transmits the port description TLV exit Exit to Global Config mode. exit Exit to Privileged EXEC mode. show lldp interface all View LLDP settings for all interfaces. Viewing and Clearing LLDP Information Beginning in Privileged EXEC mode, use the following commands to view transmitted and received LLDP information and to view and clear LLDP statistics. Command Purpose show lldp local-device {all | interface | detail interface} View LLDP information advertised by all ports or the specified port. Include the keyword detail to see additional information. show lldp remote-device View LLDP information received by all ports or by the {all | interface | detail specified port. Include the keyword detail to see additional interface} information. clear lldp remote-data Delete all LLDP information from the remote data table. show lldp statistics View LLDP traffic statistics. clear lldp statistics Reset the LLDP statistics counters to zero. 780 Discovering Network Devices Configuring LLDP-MED Settings Beginning in Privileged EXEC mode, use the following commands to configure LLDP-MED settings that affect the entire switch. Command Purpose configure Enter Global Configuration mode. lldp med faststartrepeatcount Specifies the number of LLDP PDUs that will be transmitted when the protocol is enabled. interface interface Enter interface configuration mode for the specified Ethernet interface. lldp med Enable LLDP-MED on the interface. lldp med confignotification Allow the port to send topology change notifications. count lldp med transmit-tlv Specify which optional TLVs in the LLDP MED set are [capabilities] [network- transmitted in the LLDP PDUs. policy] [location] [inventory] exit Exit to Global Config mode. exit Exit to Privileged EXEC mode. show lldp med View global LLDP-MED settings. show lldp med interface View LLDP-MED settings for all ports or for the specified {all | interface} port. Discovering Network Devices 781 Viewing LLDP-MED Information Beginning in Privileged EXEC mode, use the following commands to view information about the LLDP-MED Protocol Data Units (PDUs) that are sent and have been received. Command Purpose show lldp med localdevice detail interface View LLDP information advertised by the specified port. show lldp remote-device View LLDP-MED information received by all ports or by {all | interface | detail the specified port. Include the keyword detail to see interface} additional information. Device Discovery Configuration Examples This section contains the following examples: • Configuring ISDP • Configuring LLDP Configuring ISDP This example shows how to configure ISDP settings on the switch. To configure the switch: 1 Specify the number of seconds that a remote device should keep the ISDP information sent by the switch before discarding it. console#configure console(config)#isdp holdtime 60 2 Specify how often, in seconds, the ISDP-enabled ports should transmit information. console(config)#isdp timer 45 3 Enable ISDP on interface 1/0/3. console(config)#interface tengigabitEthernet1/0/3 console(config-if-Te1/0/3)#isdp enable 4 Exit to Privileged EXEC mode and view the LLDP settings for the switch and for interface 1/0/3. console(config-if-Te1/0/3)# 782 Discovering Network Devices console#show isdp Timer....................................45 Hold Time................................60 Version 2 Advertisements.................Enabled Neighbors table time since last change...00 days 00:00:00 Device ID................................none Device ID format capability..............Serial Number, Host Name Device ID format.........................Serial Number console#show isdp interface te1/0/3 Interface --------------Te1/0/3 Mode ---------Enabled Configuring LLDP This example shows how to configure LLDP settings for the switch and to allow 10-Gigabit Ethernet port 1/0/3 to transmit all LLDP information available. To configure the switch: 1 Configure the transmission interval, hold multiplier, and reinitialization delay for LLDP PDUs sent from the switch. console#configure console(config)#lldp timers interval 60 hold 5 reinit 3 2 Enable port 1/0/3 to transmit and receive LLDP PDUs. console(config)#interface TengigabitEthernet1/0/3 console(config-if-Te1/0/3)#lldp transmit console(config-if-Te1/0/3)#lldp receive 3 Enable port 1/0/3 to transmit management address information in the LLDP PDUs and to send topology change notifications if a device is added or removed from the port. console(config-if-Te1/0/3)#lldp transmit-mgmt console(config-if-Te1/0/3)#lldp notification 4 Specify the TLV information to be included in the LLDP PDUs transmitted from port 1/0/3. console(config-if-Te1/0/3)#lldp transmit-tlv sysname sys-desc sys-cap port-desc 5 Set the port description to be transmitted in LLDP PDUs. Discovering Network Devices 783 console(config-if-Te1/0/3)#description “Test Lab Port” 6 Exit to Privileged EXEC mode. console(config-if-Te1/0/3)# 7 View global LLDP settings on the switch. console#show lldp LLDP Global Configuration Transmit Interval..................... Transmit Hold Multiplier.............. Reinit Delay.......................... Notification Interval................. 60 seconds 5 3 seconds 5 seconds 8 View summary information about the LLDP configuration on port 1/0/3. console#show lldp interface te1/0/3 LLDP Interface Configuration Interface --------Te1/0/3 Link -----Down Transmit -------Enabled Receive -------Enabled Notify -------Enabled TLVs ------0,1,2,3 Mgmt ---Y TLV Codes: 0- Port Description, 1- System Name 2- System Description, 3- System Capabilities 9 View detailed information about the LLDP configuration on port 1/0/3. console#show lldp local-device detail te1/0/3 LLDP Local Device Detail Interface: Te1/0/3 Chassis ID Subtype: MAC Address Chassis ID: 00:1E:C9:AA:AA:07 Port ID Subtype: Interface Name Port ID: Te1/0/3 System Name: console System Description: Dell Networking N3048 784 Discovering Network Devices Port Description: Test Lab Port System Capabilities Supported: bridge, router System Capabilities Enabled: bridge Management Address: Type: IPv4 Address: 192.168.2.1 Discovering Network Devices 785 786 Discovering Network Devices 24 Configuring Port-Based Traffic Control This chapter describes how to configure features that provide traffic control through filtering the type of traffic or limiting the speed or amount of traffic on a per-port basis. The features this section describes includes flow control, storm control, protected ports, and Link Local Protocol Filtering (LLPF), which is also known as Cisco Protocol Filtering. The topics covered in this chapter include: • Port-Based Traffic Control Overview • Default Port-Based Traffic Control Values • Configuring Port-Based Traffic Control (Web) • Configuring Port-Based Traffic Control (CLI) • Port-Based Traffic Control Configuration Example Port-Based Traffic Control Overview Table 24-1 provides a summary of the features this chapter describes. Table 24-1. Port-Based Traffic Control Features Feature Description Flow control Allows traffic transmission between a switch port and another Ethernet device to be paused for a specified period of time when congestion occurs. Storm control Limits the amount of broadcast, unknown unicast, and multicast frames accepted and forwarded by the switch. Protected ports Prevents traffic from flowing between members of the same protected port group. LLPF Filters proprietary protocols that should not normally be relayed by a bridge. Configuring Port-Based Traffic Control 787 The Priority Flow Control (PFC) feature, which is available on the N4000 switches only, provides a way to distinguish which traffic on a physical link is paused when congestion occurs based on the priority of the traffic. For more information, see "Configuring Data Center Bridging Features" on page 983. What is Flow Control? IEEE 802.3 Annex 31B flow control allows nodes that transmit at slower speeds to communicate with higher speed switches by requesting that the higher speed switch refrain from sending packets. Transmissions are temporarily halted to prevent buffer overflows. Enabling the flow control feature allows Dell Networking series switches to process pause frames received from connected devices. Dell Networking switches do not transmit pause frames. Flow control is supported only on ports that are configured for full-duplex mode of operation. What is Storm Control? A LAN storm is the result of an excessive number of broadcast, multicast, or unknown unicast messages simultaneously transmitted across a network by a single port. Forwarded message responses can overload network resources and cause network congestion. The storm control feature allows the switch to measure the incoming broadcast, multicast, and/or unknown unicast packet rate per port and discard packets when the rate exceeds the defined threshold. Storm control is enabled per interface, by defining the packet type and the rate at which the packets are transmitted. For each type of traffic (broadcast, multicast, or unknown unicast) you can configure a threshold level, which is expressed as a percentage of the total available bandwidth on the port. If the ingress rate of that type of packet is greater than the configured threshold level the port drops the excess traffic until the ingress rate for the packet type falls below the threshold. The actual rate of ingress traffic required to activate storm-control is based on the size of incoming packets and the hard-coded average packet size of 512 bytes - used to calculate a packet-per-second (pps) rate - as the forwardingplane requires PPS versus an absolute rate Kbps. For example, if the 788 Configuring Port-Based Traffic Control configured limit is 10%, this is converted to ~25000 PPS, and this PPS limit is set in the hardware. You get the approximate desired output when 512 bytes packets are used. What are Protected Ports? The switch supports up to three separate groups of protected ports. Traffic can flow between protected ports belonging to different groups, but not within the same group. A port can belong to only one protected port group. You must remove an interface from one group before adding it to another group. Port protection occurs within a single switch. Protected port configuration does not affect traffic between ports on two different switches. No traffic forwarding is possible between two protected ports. What is Link Local Protocol Filtering? The Link Local Protocol Filtering (LLPF) feature can help troubleshoot network problems that occur when a network includes proprietary protocols running on standards-based switches. LLPF allows Dell Networking N2000, N3000, and N4000 series switches to filter out various Cisco proprietary protocol data units (PDUs) and/or ISDP packets if problems occur with these protocols running on standards-based switches. If certain protocol PDUs cause unexpected results, LLPF can be enabled to prevent those PDUs from being processed by the switch. The LLPF feature can be configured per-port to block any combination (or all) of the following PDUs: • Industry Standard Discovery Protocol (ISDP) • VLAN Trunking Protocol (VTP) • Dynamic Trunking Protocol (DTP) • UniDirectional Link Detection (UDLD) • Port Aggregation Protocol (PAgP) • Shared Spanning Tree Protocol (SSTP) Configuring Port-Based Traffic Control 789 Access Control Lists (ACLs) and LLPF can exist on the same interface. However, the ACL rules override the LLPF rules when there is a conflict. Similarly, DiffServ and LLPF can both be enabled on an interface, but DiffServ rules override LLPF rules when there is a conflict. If Industry Standard Discovery Protocol (ISDP) is enabled on an interface, and the LLPF feature on an interface is enabled and configured to drop ISDP PDUs, the ISDP configuration overrides the LLPF configuration, and the ISDP PDUs are allowed on the interface. Default Port-Based Traffic Control Values Table 24-2 lists the default values for the port-based traffic control features that this chapter describes. Table 24-2. Default Port-Based Traffic Control Values Feature Default Flow control Enabled Storm control Disabled Protected ports None LLPF No protocols are blocked 790 Configuring Port-Based Traffic Control Configuring Port-Based Traffic Control (Web) This section provides information about the OpenManage Switch Administrator pages to use to control port-based traffic on a Dell Networking N2000, N3000, and N4000 series switches. For details about the fields on a page, click at the top of the page. Flow Control (Global Port Parameters) Use the Global Parameters page for ports to enable or disable flow control support on the switch. To display the Global Parameters page, click Switching → Ports → Global Parameters in the navigation menu. Figure 24-1. Global Port Parameters Configuring Port-Based Traffic Control 791 Storm Control Use the Storm Control page to enable and configure the storm control feature. To display the Storm Control interface, click Switching → Ports → Storm Control in the navigation menu. Figure 24-2. Storm Control Configuring Storm Control Settings on Multiple Ports To configure storm control on multiple ports: 1 Open the Storm Control page. 2 Click Show All to display the Storm Control Settings Table. 3 In the Ports list, select the check box in the Edit column for the port to configure. 4 Select the desired storm control settings. 792 Configuring Port-Based Traffic Control Figure 24-3. Storm Control 5 Click Apply. Configuring Port-Based Traffic Control 793 Protected Port Configuration Use the Protected Port Configuration page to prevent ports in the same protected ports group from being able to see each other’s traffic. To display the Protected Port Configuration page, click Switching → Ports → Protected Port Configuration in the navigation menu. Figure 24-4. Protected Port Configuration Configuring Protected Ports To configure protected ports: 1 Open the Protected Ports page. 2 Click Add to display the Add Protected Group page. 3 Select a group (0–2). 4 Specify a name for the group. 794 Configuring Port-Based Traffic Control Figure 24-5. Add Protected Ports Group 5 Click Apply. 6 Click Protected Port Configuration to return to the main page. 7 Select the port to add to the group. 8 Select the protected port group ID. Figure 24-6. Add Protected Ports 9 Click Apply. 10 To view protected port group membership information, click Show All. Configuring Port-Based Traffic Control 795 Figure 24-7. View Protected Port Information 11 To remove a port from a protected port group, select the Remove check box associated with the port and click Apply. LLPF Configuration Use the LLPF Interface Configuration page to filter out various proprietary protocol data units (PDUs) and/or ISDP if problems occur with these protocols running on standards-based switches. To display the LLPF Interface Configuration page, click Switching → Network Security → Proprietary Protocol Filtering → LLPF Interface Configuration the navigation menu. 796 Configuring Port-Based Traffic Control Figure 24-8. LLPF Interface Configuration To view the protocol types that have been blocked for an interface, click Show All. Figure 24-9. LLPF Filtering Summary Configuring Port-Based Traffic Control 797 Configuring Port-Based Traffic Control (CLI) This section provides information about the commands you use to configure port-based traffic control settings. For more information about the commands, see the Dell Networking N2000, N3000, and N4000 Series Switches CLI Reference Guide at support.dell.com/manuals. Configuring Flow Control and Storm Control Beginning in Privileged EXEC mode, use the following commands to configure the flow control and storm control features. Command Purpose configure Enter global configuration mode. flowcontrol Globally enable flow control. interface interface Enter interface configuration mode for the specified interface. The interface variable includes the interface type and number, for example tengigabitethernet 1/0/3. You can also specify a range of interfaces with the interface range command, for example, interface range tengigabitethernet 1/0/8-12 configures interfaces 8, 9, 10, 11, and 12. storm-control broadcast Enable broadcast storm recovery mode on the interface and (optionally) set the threshold. [level rate] rate — threshold as percentage of port speed. The percentage is converted to a PacketsPerSecond value based on a 512 byte average packet size. storm-control multicast Enable multicast storm recovery mode on the interface [level rate] and (optionally) set the threshold. rate — threshold as percentage of port speed. The percentage is converted to a PacketsPerSecond value based on a 512 byte average packet size. storm-control unicast [level rate] Enable unknown unicast storm recovery mode on the interface and (optionally) set the threshold. rate — threshold as percentage of port speed. The percentage is converted to a PacketsPerSecond value based on a 512 byte average packet size. 798 Configuring Port-Based Traffic Control Command Purpose CTRL + Z Exit to Privileged EXEC mode. show interfaces detail interface Display detailed information about the specified interface, including the flow control status. show storm-control View whether 802.3x flow control is enabled on the switch. show storm-control [interface | all] View storm control settings for all interfaces or the specified interface. Configuring Protected Ports Beginning in Privileged EXEC mode, use the following commands to add a name to a protected port group and add ports to the group. Command Purpose configure Enter global configuration mode. switchport protected groupid name name Specify a name for one of the three protected port groups. • groupid — Identifies which group the port is to be protected in. (Range: 0-2) • name — Name of the group. (Range: 0-32 characters) interface interface Enter interface configuration mode for the specified interface. The interface variable includes the interface type and number, for example tengigabitethernet 1/0/3. switchport protected Add the interface to the specified protected port group. CTRL + Z Exit to Privileged EXEC mode. show switchport protected View protected group and port information. groupid Configuring Port-Based Traffic Control 799 Configuring LLPF Beginning in Privileged EXEC mode, use the following commands to configure LLPF settings. Command Purpose configure Enter global configuration mode. interface interface Enter interface configuration mode for the specified interface. The interface variable includes the interface type and number, for example tengigabitethernet 1/0/3. You can also specify a range of interfaces with the interface range command, for example, interface range tengigabitethernet 1/0/8-12 configures interfaces 8, 9, 10, 11, and 12. service-acl input Use the appropriate keyword, or combination of keywords {blockcdp | blockvtp | to block any (or all) of the following PDUs on the blockdtp | blockudld | interface: blockpagp | blocksstp | • VTP blockall} • DTP • UDLD • PAgP • SSTP • All CTRL + Z Exit to Privileged EXEC mode. show service-acl interface {interface | all} View information about the blocked PDUs on the specified interface or all interfaces. 800 Configuring Port-Based Traffic Control Port-Based Traffic Control Configuration Example The commands in this example configure storm control, LLPF, and protected port settings for various interfaces on the switch. The storm control configuration in this example sets thresholds on the switch so that if broadcast traffic occupies more than 10% on the bandwidth on any physical port, the interface blocks the broadcast traffic until the measured amount of this traffic drops below the threshold. The LLPF configuration in this example disables all PAgP and VTP PDUs from being forwarded on any switch port or LAG. The protected port configuration in this example prevents the clients connected to ports 3, 4, and 9 from being able to communicate with each other. To configure the switch: 1 Configure storm control for broadcast traffic on all physical interfaces. console(config)#interface range te1/0/1-24 console(config-if)#storm-control broadcast level 10 2 Configure LLPF to block PAgP and VTP PDUs on all physical interfaces. console(config-if)#service-acl blockpagp blockvtp console(config-if)#exit 3 Specify a name for protected port group 0. console(config)#protected 0 name clients 4 Add the ports to the protected port group. console(config)#interface te1/0/3 console(config-if-Te1/0/3)#switchport protected 0 console(config-if-Te1/0/3)#exit console(config)#interface te1/0/4 console(config-if-Te1/0/4)#switchport protected 0 console(config-if-Te1/0/4)#exit console(config)#interface te1/0/9 console(config-if-Te1/0/9)#switchport protected 0 console(config-if-Te1/0/9)#exit console(config)#exit Configuring Port-Based Traffic Control 801 5 Verify the configuration. console#show storm-control te1/0/1 Bcast Bcast Mcast Mcast Ucast Ucast Intf Mode Level Mode Level Mode Level ------ ------- ------- ------- ------- ------- ------Te1/0/1 Enable 10 Enable 5 Disable 5 console#show service-acl interface te1/0/1 Protocol --------------CDP VTP DTP UDLD PAGP SSTP ALL Mode ---------Disabled Enabled Disabled Disabled Enabled Disabled Disabled console#show switchport protected 0 Name......................................... "clients" Member Ports: Te1/0/1, Te1/0/2, Te1/0/3, Te1/0/4, Te1/0/9 802 Configuring Port-Based Traffic Control 25 Configuring L2 Multicast Features This chapter describes the layer 2 multicast features on the Dell Networking series switches. The features this chapter describes include bridge multicast flooding and forwarding, Internet Group Management Protocol (IGMP) snooping, Multicast Listener Discovery (MLD) snooping, and Multicast VLAN Registration (MVR). The topics covered in this chapter include: • L2 Multicast Overview • Snooping Switch Restrictions • Default L2 Multicast Values • Configuring L2 Multicast Features (Web) • Configuring L2 Multicast Features (CLI) • Case Study on a Real-World Network Topology L2 Multicast Overview Multicast traffic is traffic from one source that has multiple destinations. The L2 multicast features on the switch help control network flooding of Ethernet multicast and IP multicast traffic by keeping track of multicast group membership. It is essential that a multicast router be connected to a Dell Networking layer 2 multicast switch for IGMP/MLD snooping to operate properly. The presence of a multicast router allows the snooping switch to relay IGMP reports to the router and to forward multicast data sources to the multicast router as well as restrict flooding of multicast sources in a VLAN. Multicast Flooding and Forwarding Flooding behavior is to send incoming multicast packets to all ports in the VLAN other than the ingress port. Forwarding behavior is to send incoming multicast packets to selected ports in the VLAN. Forwarding behavior is Configuring L2 Multicast Features 803 desirable as it reduces the network load by sending packets only to other hosts/switches/routers that have indicated an interest in receiving the multicast. If L2 snooping is not enabled, multicast packets are flooded in the ingress VLAN. What Are the Multicast Bridging Features? The Dell Networking series switches support multicast forwarding and multicast flooding. For multicast traffic, the switch uses a database called the Layer 2 Multicast Forwarding Database (MFDB) to make forwarding decisions for packets that arrive with a multicast destination MAC address. By limiting multicasts to only certain ports in the switch, traffic is prevented from going to parts of the network where that traffic is unnecessary. When a packet enters the switch, the destination MAC address is combined with the VLAN ID, and a search is performed in the Layer 2 MFDB. If no match is found, then the packet is flooded. If a match is found, then the packet is forwarded only to the ports that are members of that multicast group within the VLAN. Multicast traffic destined to well-known (reserved) multicast IP addresses (control plane traffic) is always flooded to all ports in the VLAN. The wellknown IP multicast addresses are 224.0.0.x for IPv4 and FF0x:: for IPv6. Multicast data traffic is flooded to all ports in the VLAN if no multicast router ports have been identified. Once a multicast router port is identified, multicast data traffic is forwarded to the multicast router ports. The MFDB is populated by snooping the membership reports sent to the multicast routers. This causes multicast data traffic to be forwarded to any hosts joining the multicast group. What Is L2 Multicast Traffic? L3 IP multicast traffic is traffic that is destined to a host group. Host groups are identified by class D IPv4 addresses, which range from 224.0.1.0 to 239.255.255.255, or by FF0x:: or FF3x:: IPv6 addresses. In contrast to L3 multicast traffic, L2 multicast traffic is identified by the MAC address, i.e., the range 01:00:5e:00:00:00 to 01:00:5e:7f:ff:ff:ff for IPv4 multicast traffic or 33:33:xx:xx:xx:xx for IPv6 multicast traffic. 804 Configuring L2 Multicast Features When a packet with a broadcast or multicast destination MAC address is received, the switch will flood a copy into each of the remaining network segments in accordance with the IEEE MAC Bridge standard. Eventually, the packet is made accessible to all nodes connected to the network. This approach works well for broadcast packets that are intended to be seen or processed by all connected nodes. In the case of multicast packets, however, this approach could lead to less efficient use of network bandwidth, particularly when the packet is intended for only a small number of nodes. Packets will be flooded into network segments where no node has any interest in receiving the packet. What Is IGMP Snooping? IGMP snooping allows the switch to snoop on IGMP exchanges between hosts and multicast routers and perform multicast forwarding within a VLAN. The IGMP snooping feature complies with RFC 4541. When a switch “sees” an IGMP report from a host for a given multicast address, the switch adds the host's interface/VLAN to the L2 multicast group forwarding table and floods the report to all ports in the VLAN. When the switch sees a leave message for the group, it removes the host interface/VLAN from the L2 multicast group forwarding table. IGMP snooping learns about multicast routers by listening for the following messages: • An IGMP query packet. • PIMv1 (IGMP type 0x14) packets with destination IP address 224.0.0.13. • DVMRP (IGMP type 0x13) packets with destination IP address 224.0.0.4. • PIMv2 (IP protocol type 0x67) packets with destination IP address 224.0.0.13. Group addresses that fall into the range 224.0.0.x are never pruned by IGMP snooping—they are always flooded to all ports in the VLAN. Note that this flooding is based on the IP address, not the corresponding 01-00-5e-00-00-xx MAC address. When a multicast router is discovered, its interface is added to the interface distribution list for all multicast groups in the VLAN. If a switch is connected to a multicast source and no client, the switch filters the traffic from that group to all interfaces in the VLAN. If the switch sees an IGMP join from a host in the same VLAN, then it forwards the traffic to the host. Likewise, if Configuring L2 Multicast Features 805 the switch sees a multicast router in the VLAN, it forwards the group to the multicast router and does not flood in the VLAN. There is a user option to cause the switch to flood multicast sources in the VLAN if no multicast clients are present. By default, dynamically discovered multicast routers are aged out every five minutes. The user can control whether or not multicast routers age out. If all multicast routers age out, the switch floods the VLAN with any received multicast groups. Multicast routers send an IGMP query every 60 seconds. This query is intercepted by the switch and forwarded to all ports in the VLAN. All hosts that are members of the group answer that query. The switch intercepts the replies and forwards only one report per group from all of the received responses. In summary: • IGMP snooping controls the flooding/forwarding behavior for multicast groups. Multicast data is flooded in the VLAN until a multicast router port is identified. • IGMP snooping is enabled by default • IGMP snooping forwards multicast sources to multicast routers by default • Reserved multicast IP addresses (224.0.0.x) are always flooded to all ports in the VLAN • Unregistered multicast traffic may be flooded in the VLAN by a user configuration option. NOTE: It is strongly recommended that operators enable MLD snooping if IGMP snooping is enabled and vice-versa. This is because both IGMP snooping and MLD snooping utilize the same forwarding table and not enabling both may cause unwanted pruning of protocol packets utilized by other protocols, e.g. OSPFv3. NOTE: IGMP snooping (and IGMP querier) validates IGMP packets. As part of the validation, IGMP checks for the router alert option. If other devices in the network do not send IGMP packets with the router alert option, IGMP snooping (and snoooping querier) will discard the packet. Use the no ip igmp snooping router-alert-check command to disable checking for the router alert option. 806 Configuring L2 Multicast Features IGMP Snooping Querier When PIM and IGMP are enabled in a network with IP multicast routing, the IP multicast router acts as the IGMP querier. However, if the IP-multicast traffic in a VLAN needs to be Layer 2 switched only, an IP-multicast router is not required. The IGMP snooping querier can perform the role of generating IGMP queries that would normally be performed by the multicast router. NOTE: Without an IP-multicast router on a VLAN, you must configure another switch as the IGMP querier so that it can send queries. When IGMP snooping querier is enabled, the querier switch sends out periodic IGMP queries that trigger IGMP report messages from the hosts that want to receive IP multicast traffic. The IGMP snooping feature listens to these IGMP reports to identify multicast router ports. If there is another querier in the network and the local querier is in election mode, then the querier with the lower IP address is elected and the other querier stops querying. If the local querier is not in election mode and another querier is detected, the local querier stops querying. What Is MLD Snooping? In IPv4, Layer 2 switches use IGMP snooping to limit the flooding of multicast traffic by dynamically configuring the multicast forwarding database so that multicast data traffic is forwarded to only those ports associated with a multicast router or host that has indicated an interest in receiving a particular multicast group. In IPv6, MLD snooping performs a similar function. With MLD snooping, IPv6 multicast data is selectively forwarded to a list of ports that want to receive the data instead of being flooded to all ports in a VLAN. This list is constructed in the MFDB by snooping IPv6 multicast control packets. MLD snooping floods multicast data packets until a multicast router port has been identified. MLD snooping forwards unregistered multicast data packets to IPv6 multicast routers. MLD snooping discovers multicast routers by listening for MLD queries and populates the MFDB. MLD Snooping learns of multicast routers by listening for the following packets: • MLD query packets Configuring L2 Multicast Features 807 • PIMv2 hello packets with destination IP address as FF02::D Dynamically learned multicast routers are timed out after an adminstratorconfigurable period of time. MLD is a protocol used by IPv6 multicast routers to discover the presence of multicast listeners (nodes wishing to receive IPv6 multicast packets) on its directly-attached links and to discover which multicast packets are of interest to neighboring nodes. MLD is derived from IGMP; MLD version 1 (MLDv1) is equivalent to IGMPv2, and MLD version 2 (MLDv2) is equivalent to IGMPv3. MLD is a subprotocol of Internet Control Message Protocol version 6 (ICMPv6), and MLD messages are a subset of ICMPv6 messages. The switch snoops both MLDv1 and MLDv2 protocol packets and forwards IPv6 multicast data based on destination IPv6 multicast MAC addresses (33:33::). The switch floods multicast control plane traffic addressed to the permanently assigned (well-known) multicast address FF0x::/8 to all ports in the VLAN, except for MLD packets, which are handled according the MLD snooping rules. NOTE: It is strongly recommended that users enable IGMP snooping if MLD snooping is enabled and vice-versa. This is because both IGMP snooping and MLD snooping utilize the same forwarding table, and not enabling both may cause unwanted pruning of protocol packets utilized by other protocols, e.g. OSPFv2. What Is Multicast VLAN Registration? IGMP snooping helps limit multicast traffic when member ports are in the same VLAN; however, when ports belong to different VLANs, a copy of the multicast stream is sent to each VLAN that has member ports in the multicast group. MVR eliminates the need to duplicate the multicast traffic when multicast group member ports belong to different VLANs. MVR uses a dedicated multicast VLAN to forward multicast traffic over the L2 network. Only one MVLAN can be configured per switch, and it is used only for certain multicast traffic, such as traffic from an IPTV application, to avoid duplication of multicast streams for clients in different VLANs. Clients can dynamically join or leave the mutlicast VLAN without interfering with their membership in other VLANs. MVR, like IGMP snooping, allows a layer 2 switch to listen to IGMP messages to learn about multicast group membership. 808 Configuring L2 Multicast Features There are two types of MVR ports: source and receiver. • Source port is the port where multicast traffic is flowing to. It has to be the member of so called multicast VLAN. • Receiver port is the port where listening host is connected to the switch. It can be the member of any VLAN, except multicast VLAN. There are two configured learning modes of the MVR operation: dynamic and compatible. • In the dynamic mode MVR learns existent multicast groups by parsing the IGMP queries from router on source ports and forwarding the IGMP joins from the hosts to the router. • In the compatible mode MVR does not learn multicast groups, but they have to be configured by administrator and protocol does not forward joins from the hosts to the router. To work in this mode the IGMP router has to be configured to transmit required multicast streams to the network with the MVR switch. Enabling MVR and IGMP on the Same Interface MVR and IGMP snooping operate independently and can both be enabled on an interface. When both MVR and IGMP snooping are enabled, MVR listens to the IGMP join and report messages for static multicast group information, and IGMP snooping manages dynamic multicast groups. When Are L3 Multicast Features Required? In addition to L2 multicast features, the switch suports IPv4 and IPv6 multicast features. You configure the IPv4/IPv6 multicast features if the switch functions as a multicast router that can route multicast traffic between VLAN routing interfaces. In this case, you must enable a multicast routing protocol on the switch, such as PIM-SM. For information about L3 multicast features, see "Managing IPv4 and IPv6 Multicast" on page 1337. If the switch functions as a multicast router, it is possible to enable IGMP so that IGMP forwards multicast traffic for directly connected hosts between VLANs. It is recommended that IGMP snooping and MLD snooping be disabled in L3 multicast routed networks. Configuring L2 Multicast Features 809 NOTE: If a multicast source is connected to a VLAN on which both L3 multicast and IGMP snooping are enabled, the multicast source is forwarded to the mrouter ports that have been discovered when the multicast source is first seen. If a new mrouter is later discovered on a different port, the multicast source data is not forwarded to the new port. Likewise, if an existing mrouter times out or stops querying, the multicast source data continues to be forwarded to the original mrouter port. If a host in the VLAN subsequently joins or leaves the group, the list of mrouter ports is not updated for the multicast source and the forwarding of the multicast source is not adjusted. The workaround to this limitation is to disable IGMP/MLD snooping and avoid the use of multi-access VLANs in L3 multicast routed topologies. NOTE: If MVR is enabled, IP Multicast should be disabled. Multicast routing and MVR cannot coexist on a switch. For information about configuring Dell Networking N2000, N3000, and N4000 series switches as a multicast router that also performs IGMP snooping, see "Configuring Multicast VLAN Routing With IGMP and PIMSM" on page 1417. What Are GARP and GMRP? Generic Attribute Registration Protocol (GARP) is a general-purpose protocol that registers any network connectivity or membership-style information. GARP defines a set of switches interested in a given network attribute, such as VLAN ID or multicast address. Dell Networking series switches can use GARP functionality for two applications: • GARP VLAN Registration Protocol (GVRP) to help dynamically manage VLAN memberships on trunk ports. • GARP Multicast Registration Protocol (GMRP) to help control the flooding of multicast traffic by keeping track of group membership information. GVRP and GMRP use the same set of GARP Timers to specify the amount of time to wait before transmitting various GARP messages. 810 Configuring L2 Multicast Features GMRP is similar to IGMP snooping in its purpose, but IGMP snooping is more widely used. GMRP must be running on both the host and the switch to function properly and IGMP/MLD snooping must be disabled on the switch, as IGMP snooping and GMRP cannot simultaneously operate within the same VLAN. Configuring L2 Multicast Features 811 Snooping Switch Restrictions Partial IGMPv3 and MLDv2 Support The IGMPv3 and MLDv2 protocols allow multicast listeners to specify the list of hosts from which they want to receive the traffic. However the Dell Networking snooping switch does not track this information. IGMPv3/MLDv2 Report messages that have the group record type CHANGE_TO_INCLUDE_MODE with a null source list are treated as Leave messages. All other report messages are treated as IGMPv2/MLDv1 Report messages. MAC Address-Based Multicast Group The L2 multicast forwarding table consists of the Multicast group MAC address filtering entries. For IPv4 multicast groups, 16 IP multicast group addresses map to the same multicast MAC address. For example, 224.1.1.1 and 225.1.1.1 map to the MAC address 01:00:5E:01:01:01, and IP addresses in the range [224-239].3.3.3 map to 01:00:5E:03:03:03. As a result, if a host requests 225.1.1.1, then it might receive multicast traffic of group 226.1.1.1 as well. IGMP/MLD Snooping in a Multicast Router IGMP/MLD snooping is a Layer 2 feature and is achieved by using the L2 multicast forwarding table. If a multicast source is connected to a VLAN on which both L3 multicast and IGMP/MLD snooping are enabled, the multicast source is forwarded to the mrouter ports that have been discovered when the multicast source is first seen. If a new mrouter is later discovered on a different port, the multicast source data is not forwarded to the new port. Likewise, if an existing mrouter times out or stops querying, the multicast source data continues to be forwarded to the original mrouter port. If a host in the VLAN subsequently joins or leaves the group, the list of mrouter ports is not updated for the multicast source, and the forwarding of the multicast source is not adjusted. The workaround to this limitation is to disable IGMP/MLD snooping and avoid the use of multi-access VLANs in L3 multicast routing topologies. 812 Configuring L2 Multicast Features Topologies Where the Multicast Source Is Not Directly Connected to the Querier If the multicast source is not directly connected to a multicast querier, the multicast stream is forwarded to any router ports on the switch (within the VLAN). Because multicast router queries are flooded to all ports in the VLAN, intermediate IGMP snooping switches will receive the multicast stream from the multicast source and forward it to the multicast router. Using Static Multicast MAC Configuration If configuring static multicast MAC group addresses on a port in a VLAN, it is necessary to configure all ports in the VLAN over which it is desired that the group traffic flow (both host and router) on all switches. IGMP snooping does not dynamically add ports to a VLAN for a multicast group when a static entry is configured for that group in the VLAN. This restriction applies to both multicast router-connected ports and host-connected ports. IGMP Snooping and GMRP IGMP snooping and GMRP are not compatible. Only one of IGMP snooping or GMRP should be configured to filter multicast groups for any VLAN. Simultaneous operation of GMRP and IMGP snooping is not supported and will lead to undesirable results, such as flooding in the VLAN due to the inability to identify multicast router ports. Configuring L2 Multicast Features 813 Default L2 Multicast Values Details about the L2 multicast are in Table 25-1. Table 25-1. L2 Multicast Defaults Parameter Default Value IGMP Snooping mode Enabled MLD Snooping mode Enabled Bridge multicast group None configured IGMP/MLD snooping Enabled on all VLANs IGMP/MLD snooping auto-learn Disabled IGMP/MLD snooping host timeout 260 seconds IGMP/MLD snooping multicast router timeout 300 seconds IGMP/MLD snooping leave timeout 10 seconds IGMP snooping querier Disabled IGMP version v2 MLD version v1 IGMP/MLD snooping querier query interval 60 seconds IGMP/MLD snooping querier expiry interval 60 seconds IGMP/MLD snooping VLAN querier Disabled VLAN querier election participate mode Disabled Snooping Querier VLAN Address 0.0.0.0 MVR running Disabled MVR multicast VLAN 1 MVR max multicast groups 256 MVR Global query response time 5 tenths of a second MVR Mode Compatible GARP Leave Timer 60 centiseconds GARP Leave All Timer 1000 centiseconds GARP Join Timer 20 centiseconds 814 Configuring L2 Multicast Features Table 25-1. L2 Multicast Defaults (Continued) Parameter Default Value GMRP Disabled globally and per-interface Configuring L2 Multicast Features 815 Configuring L2 Multicast Features (Web) This section provides information about the OpenManage Switch Administrator pages for configuring and monitoring L2 multicast features on a Dell Networking N2000, N3000, and N4000 series switches. For details about the fields on a page, click at the top of the page. Multicast Global Parameters Use the Multicast Global Parameters page to enable or disable IGMP snooping, or MLD snooping on the switch. To display the Multicast Global Parameters page, click Switching → Multicast Support → Global Parameters in the navigation menu. Figure 25-1. Multicast Global Parameters NOTE: It is strongly recommended that users enable IGMP snooping if MLD snooping is enabled and vice-versa. This is because both IGMP snooping and MLD snooping utilize the same forwarding table, and not enabling both may cause unwanted pruning of protocol packets utilized by other protocols, e.g. OSPFv2. 816 Configuring L2 Multicast Features Bridge Multicast Group Use the Bridge Multicast Group page to create new multicast service groups or to modify ports and LAGs assigned to existing multicast service groups. Attached interfaces display in the Port and LAG tables and reflect the manner in which each is joined to the Multicast group. To display the Bridge Multicast Group page, click Switching → Multicast Support → Bridge Multicast Group in the navigation menu. Figure 25-2. Bridge Multicast Group Understanding the Port and LAG Member Tables The Bridge Multicast Group tables display which Ports and LAGs are members of the multicast group, and whether they’re static (S), dynamic (D), or forbidden (F). The tables have two rows: Static and Current. Only the Static row is accessible from this page. The Current row is updated when the Static row is changed and Apply is clicked. The Bridge Multicast Group page contains two editable tables: • Unit and Ports — Displays and assigns multicast group membership to ports. To assign membership, click in Static for a specific port. Each click toggles between S, F, and blank. See Table 25-2 for definitions. • LAGs — Displays and assigns multicast group membership to LAGs. To assign membership, click in Static for a specific LAG. Each click toggles between S, F, and blank. See Table 25-2 for definitions. Configuring L2 Multicast Features 817 Table 25-2 contains definitions for port/LAG IGMP management settings. Table 25-2. Port/LAG IGMP Management Settings Port Control Definition D Dynamic: Indicates that the port/LAG was dynamically joined to the Multicast group (displays in the Current row). S Static: Attaches the port to the Multicast group as a static member in the Static row. Displays in the Current row once Apply is clicked. F Forbidden: Indicates that the port/LAG is forbidden entry into the Multicast group in the Static row. Displays in the Current row once Apply is clicked. Blank Blank: Indicates that the port is not attached to a Multicast group. Adding and Configuring Bridge Multicast Address Groups To configure a bridge multicast group: 1 From the Bridge Multicast Group page, click Add. The Add Bridge Multicast Group page displays. Figure 25-3. Add Bridge Multicast Group 2 Select the ID of the VLAN to add to the multicast group or to modify membership for an existing group. 3 For a new group, specify the multicast group IP or MAC address associated with the selected VLAN. 818 Configuring L2 Multicast Features 4 In the Bridge Multicast Group tables, assign a setting by clicking in the Static row for a specific port/LAG. Each click toggles between S, F, and blank. (not a member). 5 Click Apply. The bridge multicast address is assigned to the multicast group, ports/LAGs are assigned to the group (with the Current rows being updated with the Static settings), and the switch is updated. Removing a Bridge Multicast Group To delete a bridge multicast group: 1 Open the Bridge Multicast Group page. 2 Select the VLAN ID associated with the bridge multicast group to be removed from the drop-down menu. The Bridge Multicast Address and the assigned ports/LAGs display. 3 Check the Remove check box. 4 Click Apply. The selected bridge multicast group is removed, and the device is updated. Configuring L2 Multicast Features 819 MRouter Status Use the MRouter Status page to display the status of dynamically learned multicast router interfaces. To access this page, click Switching → Multicast Support → MRouter Status in the navigation panel. Figure 25-4. MRouter Status 820 Configuring L2 Multicast Features General IGMP Snooping Use the General IGMP snooping page to configure IGMP snooping settings on specific ports and LAGs. To display the General IGMP snooping page, click Switching → Multicast Support → IGMP Snooping → General in the navigation menu. Figure 25-5. General IGMP Snooping Modifying IGMP Snooping Settings for Multiple Ports, LAGs, or VLANs To modify the IGMP snooping settings: 1 From the General IGMP snooping page, click Show All. The IGMP Snooping Table displays. 2 Select the Edit checkbox for each Port, LAG, or VLAN to modify. In Figure 25-6, 2 and 3 are to be modified. Configuring L2 Multicast Features 821 Figure 25-6. Edit IGMP Snooping Settings 3 Edit the IGMP snooping fields as needed. 4 Click Apply. The IGMP snooping settings are modified, and the device is updated. Copying IGMP Snooping Settings to Multiple Ports, LAGs, or VLANs To copy IGMP snooping settings: 1 From the General IGMP snooping page, click Show All. The IGMP Snooping Table displays. 2 Select the Copy Parameters From checkbox. 3 Select a Unit/Port, LAG, or VLAN to use as the source of the desired parameters. 4 Select the Copy To checkbox for the Unit/Ports, LAGs, or VLANs that these parameters will be copied to. In Figure 25-7, the settings for VLAN 21 will be copied to ports 3 and 5. 822 Configuring L2 Multicast Features Figure 25-7. Copy IGMP Snooping Settings 5 Click Apply. The IGMP snooping settings are modified, and the device is updated. Configuring L2 Multicast Features 823 Global Querier Configuration Use the Global Querier Configuration page to configure IGMP snooping querier settings, such as the IP address to use as the source in periodic IGMP queries when no source address has been configured on the VLAN. To display the Global Querier Configuration page, click Switching → Multicast Support → IGMP Snooping → Global Querier Configuration in the navigation menu. Figure 25-8. Global Querier Configuration 824 Configuring L2 Multicast Features VLAN Querier Use the VLAN Querier page to specify the IGMP snooping querier settings for individual VLANs. To display the VLAN Querier page, click Switching → Multicast Support → IGMP Snooping → VLAN Querier in the navigation menu. Figure 25-9. VLAN Querier Adding a New VLAN and Configuring its VLAN Querier Settings To configure a VLAN querier: 1 From the VLAN Querier page, click Add. The page refreshes, and the Add VLAN page displays. Figure 25-10. Add VLAN Querier 2 Enter the VLAN ID and, if desired, an optional VLAN name. Configuring L2 Multicast Features 825 3 Return to the VLAN Querier page and select the new VLAN from the VLAN ID menu. 4 Specify the VLAN querier settings. 5 Click Apply. The VLAN Querier settings are modified, and the device is updated. To view a summary of the IGMP snooping VLAN querier settings for all VLANs on the switch, click Show All. Figure 25-11. 826 Add VLAN Querier Configuring L2 Multicast Features VLAN Querier Status Use the VLAN Querier Status page to view the IGMP snooping querier settings for individual VLANs. To display the VLAN Querier Status page, click Switching → Multicast Support → IGMP Snooping → VLAN Querier Status in the navigation menu. Figure 25-12. IGMP Snooping VLAN Querier Status Configuring L2 Multicast Features 827 MFDB IGMP Snooping Table Use the MFDB IGMP Snooping Table page to view the multicast forwarding database (MFDB) IGMP Snooping Table and Forbidden Ports settings for individual VLANs. To display the MFDB IGMP Snooping Table page, click Switching → Multicast Support → IGMP Snooping → MFDB IGMP Snooping Table in the navigation menu. Figure 25-13. 828 MFDB IGMP Snooping Table Configuring L2 Multicast Features MLD Snooping General Use the MLD Snooping General page to add MLD members. To access this page, click Switching → Multicast Support → MLD Snooping → General in the navigation panel. Figure 25-14. MLD Snooping General Modifying MLD Snooping Settings for VLANs To configure MLD snooping: 1 From the General MLD snooping page, click Show All. The MLD Snooping Table displays. Configuring L2 Multicast Features 829 Figure 25-15. MLD Snooping Table 2 Select the Edit checkbox for each VLAN to modify. 3 Edit the MLD snooping fields as needed. 4 Click Apply. The MLD snooping settings are modified, and the device is updated. 830 Configuring L2 Multicast Features Copying MLD Snooping Settings to VLANs To copy MLD snooping settings: 1 From the General MLD snooping page, click Show All. The MLD Snooping Table displays. 2 Select the Copy Parameters From checkbox. 3 Select a VLAN to use as the source of the desired parameters. 4 Select the Copy To checkbox for the VLANs that these parameters will be copied to. 5 Click Apply. The MLD snooping settings are modified, and the device is updated. MLD Snooping Global Querier Configuration Use the MLD Snooping Global Querier Configuration page to configure the parameters for the MLD snooping querier. To display the Global Querier Configuration page, click Switching → Multicast Support → MLD Snooping → Global Querier Configuration in the navigation menu. Figure 25-16. MLD Snooping Global Querier Configuration Configuring L2 Multicast Features 831 MLD Snooping VLAN Querier Use the MLD Snooping VLAN Querier page to specify the MLD snooping querier settings for individual VLANs. To display the MLD Snooping VLAN Querier page, click Switching → Multicast Support → MLD Snooping → VLAN Querier in the navigation menu. Figure 25-17. MLD Snooping VLAN Querier Adding a New VLAN and Configuring its MLD Snooping VLAN Querier Settings To configure an MLD snooping VLAN querier: 1 From the VLAN Querier page, click Add. The page refreshes, and the Add VLAN page displays. Figure 25-18. 832 Add MLD Snooping VLAN Querier Configuring L2 Multicast Features 2 Enter the VLAN ID and, if desired, an optional VLAN name. 3 Return to the VLAN Querier page and select the new VLAN from the VLAN ID menu. 4 Specify the VLAN querier settings. 5 Click Apply. The VLAN Querier settings are modified, and the device is updated. To view a summary of the IGMP snooping VLAN querier settings for all VLANs on the switch, click Show All. Figure 25-19. Add VLAN Querier Configuring L2 Multicast Features 833 MLD Snooping VLAN Querier Status Use the VLAN Querier Status page to view the MLD snooping querier settings for individual VLANs. To display the VLAN Querier Status page, click Switching → Multicast Support → MLD Snooping → VLAN Querier Status in the navigation menu. Figure 25-20. 834 MLD Snooping VLAN Querier Status Configuring L2 Multicast Features MFDB MLD Snooping Table Use the MFDB MLD Snooping Table page to view the MFDB MLD snooping table settings for individual VLANs. To display the MFDB MLD Snooping Table page, click Switching → Multicast Support → MLD Snooping → MFDB MLD Snooping Table in the navigation menu. Figure 25-21. MFDB MLD Snooping Table Configuring L2 Multicast Features 835 MVR Global Configuration Use the MVR Global Configuration page to enable the MVR feature and configure global parameters. To display the MVR Global Configuration page, click Switching → MVR Configuration → Global Configuration in the navigation panel. Figure 25-22. 836 MVR Global Configuration Configuring L2 Multicast Features MVR Members Use the MVR Members page to view and configure MVR group members. To display the MVR Members page, click Switching → MVR Configuration → MVR Members in the navigation panel. Figure 25-23. MVR Members Adding an MVR Membership Group To add an MVR membership group: 1 From the MVR Membership page, click Add. The MVR Add Group page displays. Figure 25-24. MVR Member Group 2 Specify the MVR group IP multicast address. 3 Click Apply. Configuring L2 Multicast Features 837 MVR Interface Configuration Use the MVR Interface Configuration page to enable MVR on a port, configure its MVR settings, and add the port to an MVR group. To display the MVR Interface Configuration page, click Switching → MVR Configuration → MVR Interface Configuration in the navigation panel. Figure 25-25. MVR Interface Configuration To view a summary of the MVR interface configuration, click Show All. Figure 25-26. MVR Interface Summary Adding an Interface to an MVR Group To add an interface to an MVR group: 1 From the MVR Interface page, click Add. 838 Configuring L2 Multicast Features Figure 25-27. MVR - Add to Group 2 Select the interface to add to the MVR group. 3 Specify the MVR group IP multicast address. 4 Click Apply. Removing an Interface from an MVR Group To remove an interface from an MVR group: 1 From the MVR Interface page, click Remove. Figure 25-28. MVR - Remove from Group 2 Select the interface to remove from an MVR group. 3 Specify the IP multicast address of the MVR group. 4 Click Apply. Configuring L2 Multicast Features 839 MVR Statistics Use the MVR Statistics page to view MVR statistics on the switch. To display the MVR Statistics page, click Switching → MVR Configuration → MVR Statistics in the navigation panel. Figure 25-29. 840 MVR Statistics Configuring L2 Multicast Features GARP Timers The Timers page contains fields for setting the GARP timers used by GVRP and GMRP on the switch. To display the Timers page, click Switching → GARP → Timers in the navigation panel. Figure 25-30. GARP Timers Configuring GARP Timer Settings for Multiple Ports To configure GARP timers on multiple ports: 1 Open the Timers page. 2 Click Show All to display the GARP Timers Table. Configuring L2 Multicast Features 841 Figure 25-31. Garp Timers Table 3 For each port or LAG to configure, select the check box in the Edit column in the row associated with the port. 4 Specify the desired timer values. 5 Click Apply. 842 Configuring L2 Multicast Features Copying GARP Timer Settings From One Port to Others To copy GARP timer settings: 1 Select the Copy Parameters From check box, and select the port or LAG with the settings to apply to other ports or LAGs. 2 In the Ports or LAGs list, select the check box(es) in the Copy To column that will have the same settings as the port selected in the Copy Parameters From field. 3 Click Apply to copy the settings. GMRP Parameters Use the GMRP Parameters page to configure the administrative mode of GMRP on the switch and on each port or LAG. To display the GMRP Parameters page, click Switching → GARP → GMRP Parameters in the navigation panel. Figure 25-32. GMRP Parameters Configuring GMRP Parameters on Multiple Ports To configure GMRP settings: 1 Open the GMRP Parameters page. 2 Click Show All to display the GMRP Port Configuration Table. Configuring L2 Multicast Features 843 Figure 25-33. GMRP Port Configuration Table 3 For each port or LAG to configure, select the check box in the Edit column in the row associated with the port. 4 Specify the desired timer values. 5 Click Apply. 844 Configuring L2 Multicast Features Copying Settings From One Port or LAG to Others To copy GMRP settings: 1 Select the Copy Parameters From check box, and select the port or LAG with the settings to apply to other ports or LAGs. 2 In the Ports or LAGs list, select the check box(es) in the Copy To column that will have the same settings as the port selected in the Copy Parameters From field. 3 Click Apply to copy the settings. MFDB GMRP Table Use the MFDB GMRP Table page to view all of the entries in the Multicast Forwarding Database that were created for the GMRP To display the MFDB GMRP Table page, click Switching → GARP → MFDB GMRP Table in the navigation panel. Figure 25-34. MFDB GMRP Table Configuring L2 Multicast Features 845 Configuring L2 Multicast Features (CLI) This section provides information about the commands you use to configure L2 multicast settings on the switch. For more information about the commands, see the Dell Networking N2000, N3000, and N4000 Series Switches CLI Reference Guide at support.dell.com/manuals. Because L3 IP multicast (PIM/IGMP) utilizes a separate forwarding database from L2 multicast, it is recommended that L3 multicast features, including PIM and IGMP, be disabled on L2 multicast enabled switches. Configuring Layer 2 Multicasting Beginning in Privileged EXEC mode, use the following commands to configure MAC address table features. Command Purpose configure Enter global configuration mode. mac address-table static Register a MAC-layer Multicast address in the bridge mac-multicast-address table. vlan vlan-id interface • mac-multicast-address — MAC multicast address in the interface-id format xxxx.xxxx.xxxx or xx:xx:xx:xx:xx:xx. • interface-id — A physical interface or port-channel. mac address-table multicast forbidden address vlan vlan-id {mac-multicast-address | ip-multicast-address} {add | remove} interface interface-list Forbid adding a specific Multicast address to specific ports. • mac-multicast-address — MAC multicast address in the format xxxx.xxxx.xxxx. • ip- multicast-address — IP multicast address. • add — Adds ports to the group. If no option is specified, this is the default option. • remove — Removes ports from the group. • interface-list — Specifies the interface type (portchannel, gigabitethernet, tengigabitethernet) and number. Separate nonconsecutive interfaces with a comma and no spaces; use a hyphen to designate a range of ports. exit 846 Exit to Privileged EXEC mode. Configuring L2 Multicast Features Command Purpose show mac address-table multicast [vlan vlan-id] [address mac-multicastaddress | ip-multicastaddress] [format ip | mac]] View entries in the multicast MAC address table. The show mac address-table multicast command shows only multicast addresses. Multicast address are shown along with unicast addresses if the multicast keyword is not used. Configuring IGMP Snooping on VLANs Beginning in Privileged EXEC mode, use the following commands to configure IGMP snooping settings on VLANs. Command Purpose configure Enter global configuration mode. ip igmp snooping vlan Enable IGMP snooping on the specified VLAN. ip igmp snooping vlan Specify the host time-out value for the specified VLAN. If an IGMP report for a multicast group is not received in the number of seconds specified by the seconds value, this port is deleted from the VLAN member list of that multicast group. This command also enables IGMP snooping on the VLAN. vlan-id vlan-id groupmembershipinterval seconds ip igmp snooping vlan Specify the leave time-out value for the VLAN. If an IGMP report for a multicast group is not received within the number of seconds configured with this command after an IGMP leave was received from a specific interface, the current port is deleted from the VLAN member list of that multicast group. ip igmp snooping vlan Enables IGMP snooping immediate-leave mode on the vlan-id last-memberquery-interval seconds vlan-id immediate-leave specified VLAN. Enabling immediate-leave allows the switch to immediately remove the layer 2 LAN interface from its forwarding table entry upon receiving an IGMP leave message for that multicast group without first sending out MAC-based general queries to the interface. Configuring L2 Multicast Features 847 Command Purpose ip igmp snooping vlan vlan-id mcrtexpiretime Specify the multicast router time-out value for to associate with a VLAN. This command sets the number of seconds to wait to age out an automatically-learned multicast router port. CTRL + Z Exit to Privileged EXEC mode. show ip igmp snooping groups Shows IGMP snooping configuration on all VLANs. show ip igmp snooping vlan vlan-id View the IGMP snooping settings on the VLAN. seconds Configuring IGMP Snooping Querier Beginning in Privileged EXEC mode, use the following commands to configure IGMP snooping querier settings on the switch and on VLANs. Command Purpose configure Enter global configuration mode. ip igmp snooping querier Enable the IGMP snooping querier on the switch or on [vlan vlan-id] [address the VLAN specified with the vlan-id parameter. ip-address] Use the optional ip-address parameter to specify the IP address that the snooping querier switch should use as the source address when generating periodic queries. ip igmp snooping querier Set the IGMP snooping querier query interval time, which query-interval interval- is the amount of time in seconds that the switch waits count before sending another periodic query. The range is 1–1800 seconds. ip igmp snooping querier Set the IGMP snooping querier timer expiration period. This is the time period, in seconds, that the switch timer expiry seconds remains in non-querier mode after it has discovered that there is a multicast querier in the network. ip igmp snooping querier Set the IGMP version of the query that the switch sends version version periodically. The version range is 1–2. ip igmp snooping querier Enable the IGMP snooping querier on the specified VLAN. vlan-id 848 Configuring L2 Multicast Features Command Purpose ip igmp snooping querier Allow the IGMP snooping querier to participate in the election participate vlan- querier election process when it discovers the presence of id another querier in the VLAN. When this mode is enabled, if the snooping querier finds that the other querier source address is more than the snooping querier address, it stops sending periodic queries. If the snooping querier wins the election, then it continues sending periodic queries and the other querier ceases sending queries. Use of election mode is not recommended when multicast routers are present in the network. CTRL + Z Exit to Privileged EXEC mode. show ip igmp snooping querier [detail |vlan vlan-id] View IGMP snooping querier settings configured on the switch, on all VLANs, or on the specified VLAN. Configuring MLD Snooping on VLANs Beginning in Privileged EXEC mode, use the following commands to configure MLD snooping settings on VLANs. Command Purpose configure Enter global configuration mode. ipv6 mld snooping vlan Enable MLD snooping on the specified VLAN. ipv6 mld snooping vlan Specify the host time-out value for the specified VLAN. If an MLD report for a multicast group is not received in the number of seconds specified by the seconds value, this VLAN is deleted from the member list of that multicast group. vlan-id vlan-id groupmembershipinterval seconds ipv6 mld snooping vlan- Specify the leave time-out value for the VLAN. If an MLD id last-listener-queryreport for a multicast group is not received within the number of seconds configured with this command after interval seconds an MLD leave was received from a specific interface, the current port is deleted from the VLAN member list of that multicast group. Configuring L2 Multicast Features 849 Command Purpose ipv6 mld snooping vlan Enables MLD snooping immediate-leave mode on the vlan-id immediate-leave specified VLAN. Enabling immediate-leave allows the switch to immediately remove the layer 2 LAN interface from its forwarding table entry upon receiving an MLD leave message for that multicast group without first sending out MAC-based general queries to the interface. vlan-id mcrtexpiretime seconds ipv6 mld snooping vlan Specify the multicast router time-out value for to associate with a VLAN. This command sets the number of seconds to wait to age out an automatically-learned multicast router port. CTRL + Z Exit to Privileged EXEC mode. show ipv6 mld snooping View the MLD snooping settings on the VLAN. vlan vlan-id Configuring MLD Snooping Querier Beginning in Privileged EXEC mode, use the following commands to configure MLD snooping querier settings on the switch and on VLANs. Command Purpose configure Enter global configuration mode. ipv6 mld snooping querier Enable the MLD snooping querier on the switch. ipv6 mld snooping querier vlan vlan-id [address ipv6-address] Enable the MLD snooping querier on VLAN specified with the vlan-id parameter. 850 Use the optional ip-address parameter to specify the IP address that the snooping querier switch should use as the source address when generating periodic queries. Configuring L2 Multicast Features Command Purpose ipv6 mld snooping querier election participate vlan-id Allow the MLD snooping querier to participate in the querier election process when it discovers the presence of another querier in the VLAN. When this mode is enabled, if the snooping querier finds that the other querier source address is more than the snooping querier address, it stops sending periodic queries. If the snooping querier wins the election, then it continues sending periodic queries. Use of election mode is not recommended when multicast routers are present in the network. exit Exit to Global Configuration mode. ipv6 mld snooping querier address ipv6- Specify the IP address that the snooping querier switch should use as the source address when generating periodic queries. ipv6 mld snooping querier query-interval Set the MLD snooping querier query interval time, which is the amount of time in seconds that the switch waits before sending another periodic query. The range is 1–1800 seconds. ipv6 mld snooping querier timer expiry Set the MLD snooping querier timer expiration period. This is the time period, in seconds, that the switch remains in non-querier mode after it has discovered that there is a multicast querier in the network. exit Exit to Privileged EXEC mode. address interval-count seconds show ipv6 mld snooping View MLD snooping querier settings configured on the switch, on all VLANs, or on the specified VLAN. querier [detail |vlan vlan-id] Configuring MVR Beginning in Privileged EXEC mode, use the following commands to configure MVR features on the switch. Command Purpose configure Enter global configuration mode. mvr Enable MVR on the switch. mvr vlan vlan-id Set the VLAN to use as the multicast VLAN for MVR. Configuring L2 Multicast Features 851 Command Purpose mvr querytime time Set the MVR query response time. The value for time is in units of tenths of a second. mvr mode {compatible | Specify the MVR mode of operation. dynamic} mvr group mcast-address Add an MVR membership group. [groups] • mcast-address—The group IP multicast address • group—Specifies the number of contiguous groups interface interface Enter interface configuration mode for the specified port. The interface variable includes the interface type and number, for example tengigabitethernet 1/0/3. You can also specify a range of ports with the interface range command, for example, interface range tengigabitethernet 1/0/8-12 configures interfaces 8, 9, 10, 11, and 12. mvr Enable MVR on the port. mvr immediate Enable MVR immediate leave mode on the port. mvr type {source | receiver} Specify the MVR port type. mvr vlan vlan-id group mcast-address Allow the port to participate in the specified MVR group. The vlan-id parameter is the ID of the MVR multicast VLAN. CTRL + Z Exit to Privileged EXEC mode. show ip dhcp snooping [interfaces] View the DHCP snooping global and per port configuration. show ip dhcp snooping binding [{static | dynamic}] [interface port] [vlan vlan-id] View the entries in the DHCP snooping bindings database. show mvr View information about the administrative mode of MVR. show mvr members View information about MVR groups and their members. interface show mvr interface View information about the MVR configuration for a specific port. show mvr traffic View information about IGMP traffic in the MVR table. 852 Configuring L2 Multicast Features Configuring GARP Timers and GMRP Beginning in Privileged EXEC mode, use the following commands to configure the GARP timers and to control the administrative mode GMRP on the switch and per-interface. Command Purpose configure Enter global configuration mode. garp timer {join | leave | Adjust the GARP application join, leave, and leaveall GARP timer values leaveall} timer_value The timer_value variable is in centiseconds. The range is 10-100 for join, 20-600 for leave, and 200-6000 for leaveall. gmrp enable Enable GMRP globally on the switch. interface interface Enter interface configuration mode for the specified port or LAG. The interface variable includes the interface type and number, for example tengigabitethernet 1/0/3. For a LAG, the interface type is port-channel. You can also specify a range of ports with the interface range command, for example, interface range tengigabitethernet 1/0/8-12 configures interfaces 8, 9, 10, 11, and 12. gmrp enable Enable GMRP on the interface or range of interfaces. exit Exit to Global Config mode. exit Exit to Privileged EXEC mode. show gmrp configuration View the administrative status of GMRP on the switch and all interfaces. Configuring L2 Multicast Features 853 Case Study on a Real-World Network Topology Multicast Snooping Case Study Figure 25-35 shows the topology that the scenarios in this case study use. Figure 25-35. Case Study Topology The topology in Figure 25-35 includes the following elements: 854 • Snooping Switches: D1, D2, D3 with IGMP snooping enabled on VLANs 10, 20 • Multicast Router: D4 with PIM-SM enabled and IGMP snooping disabled on VLANs 10, 20 • Multicast Listeners: Client A-G Configuring L2 Multicast Features • Multicast Sources: Server A – 239.20.30.40, Server B – 239.20.30.42 • Subnets: VLAN 10 – 192.168.10.x, VLAN 20 – 192.168.20.x • Mrouter ports: D3 – 1/0/20, D2 – PortChannel1, D1 – 1/0/15 Snooping Within a Subnet In the example network topology, the multicast source and listeners are in the same subnet VLAN 20 – 192.168.20.x/24. D4 sends periodic queries on VLAN 10 and 20, and these queries are forwarded to D1, D2, and D3 via trunk links. Snooping switches D1, D2, and D3 flood these queries in VLANs 10 and 20 to clients G, F, and D, respectively. Multicast Source and Listener directly connected to a snooping switch: Server B  Client G 1 Client G sends a report for 239.20.30.42. 2 The report is forwarded to multicast router D4 via D1 – 1/0/15 and D3 – 1/0/20. 3 A forwarding entry is created by D1 for VLAN 20, 239.20.30.42 – 1/0/8, 1/0/15. 4 Client G receives the multicast stream from Server B. 5 D3 receives the multicast stream and it is forwarded to D4 because D4 is a multicast router. 6 Client D sends a report for 239.20.30.42. 7 The report is forwarded to multicast router D4 via D3 – 1/0/20. 8 A forwarding entry is created by D3 for VLAN 20, 239.20.30.42 – 1/0/6, 1/0/20. 9 Client D receives the multicast stream from Server B. 10 Client F does not receive the multicast stream because it did not respond to queries from D4. Multicast Source and Listener connected by intermediate snooping switches: Server B  Client D 1 Client D sends a report for 239.20.30.42. 2 The report is forwarded to multicast router D4 via D3 – 1/0/20. Configuring L2 Multicast Features 855 3 A forwarding entry is created by D3 for VLAN20, 239.20.30.42 – 1/0/6, 1/0/20. 4 Client D will receive the multicast stream from Server B because it is forwarded by D1 to D3 and then to D4 because D4 is a multicast router. Because the multicast stream is present on D3, a L2 forwarding entry is created on D3, where 239.20.30.42 is not a registered group. 5 Client F does not receive the multicast stream because it did not respond to queries from D4. Snooping Switch Interaction with a Multicast Router In the example network topology, consider Client B and Server A. Both are in the same subnet VLAN10 – 192.168.10.70/24. Server A is a source for multicast stream 239.20.30.40. D4 sends periodic queries on VLAN 10 and VLAN 20, and these queries reach D1, D2, and D3 via trunk links, which in turn forward them in VLAN 10 and VLAN 20 to reach their respective attached clients. PIM-SM is enabled and IGMP snooping is disabled on router D4, and IGMP snooping is enabled on D1, D2, and D3. Multicast Source and Listener directly connected to Multicast Router on the same routing VLAN: Server A  Client B 1 Because multicast routing is enabled on D4 VLAN 10, an IP multicast table entry is created to include D4 – 1/0/15, D4 – 1/0/20 as part of the L2 forwarding list members. 2 Client B sends a report for 239.20.30.40. 3 The IP multicast table entry is modified to include only D4 – 1/0/15 as the layer 2 forwarding list member. 4 Client B receives multicast data. 5 The multicast stream is not forwarded to D3 on trunk link 1/0/20 because no other clients requested this data. Multicast Source directly connected to Multicast Router, and Listener connected to a different routing VLAN via intermediate snooping switches: Server A  Client F Clients A, D and F are in the same subnet VLAN20 - 192.168.20.70/24. Server A is in a different subnet VLAN10 – 192.168.10.70/24. 1 Client F sends a report for 239.20.30.40. 856 Configuring L2 Multicast Features 2 A multicast forwarding entry is created on D2 VLAN20, 239.20.30.40 – 1/0/20, PortChannel1. 3 The Client F report message is forwarded to D3-PortChannel1 (multicast router attached port). 4 A multicast forwarding entry is created on D3 VLAN 20, 239.20.30.40 – PortChannel1, 1/0/20. 5 The Client F report message is forwarded to D4 via D3 – 1/0/20 (multicast router attached port). 6 An IP multicast routing entry is created on D4 VLAN 10 – VLAN 20 with the L3 outgoing port list as VLAN 20 – 1/0/20. 7 The multicast stream is routed to D3. 8 The multicast stream is forwarded to listener Client F using forwarding entries created on D3 and D2. 9 Clients A and D do not receive the Server A multicast stream because they did not send a report. Multicast Source connected to Multicast Router via intermediate snooping switches, and Listener directly connected to multicast router in a different routing interface: Server B  Client B Server A and Clients B, C, and E are on the same subnet VLAN10 – 192.168.10.70/24. Server B is in a different subnet VLAN20 – 192.168.20.70/24. 1 Client B sends a report for 239.20.30.42. 2 Multicast Router D4 learns group 239.20.30.42. 3 The administrator creates a static multicast forwarding entry on D1 VLAN 20, 239.20.30.42 – 1/0/15 and on D3 VLAN 20, 239.20.30.42 – 1/0/20. 4 The multicast stream from Server B reaches D4 via trunk links because it is a statically registered group on D1 and D3. D4 is a multicast router. 5 An IP multicast routing entry is created on D4 VLAN 20 – VLAN 10 with the L3 outgoing port list as VLAN 10 – 1/0/15. 6 Client B receives multicast data from Server B. 7 Server A and Clients C and E do not receive Server B data because no report messages were sent requesting Server B traffic. Configuring L2 Multicast Features 857 Multicast Source and Listener connected to Multicast Router via intermediate snooping switches and are part of different routing VLANs: Server B  Client E Clients E, B, and C are on the same subnet VLAN10 – 192.168.10.70/24. Server B is in a different subnet VLAN20 – 192.168.20.70/24. 1 Client E sends a report for 239.20.30.42. 2 A multicast forwarding entry is created on D2 VLAN10, 239.20.30.42 – 1/0/2, PortChannel 1. 3 The report from Client E is forwarded to D3 via D2 – PortChannel 1. 4 A multicast forwarding entry is created on D3 VLAN10, 239.20.30.42 – PortChannel 1, 1/0/20. 5 The report from Client E is forwarded to D4 via D3 – 1/0/20. 6 Multicast Router D4 learns group 239.20.30.42. 7 The multicast stream from Server B reaches D4 via trunk links because it is a multicast router. 8 An IP multicast routing entry is created on D4 VLAN 20 – VLAN 10 with the L3 outgoing port list as VLAN 10 – 1/0/20. 9 Client E receives multicast data from Server B. 10 Clients B and C do not receive Server B data because no report messages were sent requesting Server B traffic. 858 Configuring L2 Multicast Features 26 Configuring Connectivity Fault Management This chapter describes how to configure the Connectivity Fault Management feature, which is specified in IEEE 802.1ag (IEEE Standard for Local and Metropolitan Area Networks Virtual Bridged Local Area Networks Amendment 5: Connectivity Fault Management). This protocol, also known as Dot1ag, enables the detection and isolation of connectivity faults at the service level for traffic that is bridged over a metropolitan Ethernet LAN. This feature is supported only on the Dell Networking 4000 series switches. The topics covered in this chapter include: • Dot1ag Overview • Default Dot1ag Values • Configuring Dot1ag (Web) • Configuring Dot1ag (CLI) • Dot1ag Configuration Example Dot1ag Overview With the emergence of Ethernet as a Metropolitan and Wide-Area Networking technology, different operators often work together to provide end-to-end services to enterprise customers. This has driven the need of a new set of OAM (Operations, Administration, and Maintenance) Protocols. Service-Level Connectivity Fault Management (CFM) is the OAM protocol provision for end-to-end service-layer instances in carrier networks. CFM provides mechanisms to support the administrator in performing connectivity checks, fault detection, fault verification and isolation, and fault notification per service in the network domain of interest. Unlike Ethernet OAM (IEEE 802.3ah), where the faults are detected and notified on a single point-to-point Configuring Connectivity Fault Management 859 IEEE Std. 802.3 LAN, Dot1ag addresses fault diagnosis at the service layer across networks comprising multiple LANs, including LANs other than 802.3 media. How Does Dot1ag Work Across a Carrier Network? A typical metropolitan area network comprises operator, service provider, and customer networks. To suit this business model, CFM relies on a functional model of hierarchical maintenance domains (MDs). These domains are assigned a unique MD level. There is a maximum of 8 levels, which can be nested but cannot overlap. Each organization can have its own maintenance domain. The MD level limits administrator access to the appropriate domain. Figure 26-1 depicts three domains: the customer subscribes to the services of a provider, who, in turn, subscribes to the services of two operators. This scenario is a likely one, since no operator has complete coverage of a large region. A service instance would span the provider network covering one or more operators. Every domain has its own network management system. Dot1ag defines OAM services that operate across these domains (the vertical arrow) and within them (the horizontal arrow) Figure 26-1. Organization of Domains Access Links, 802.3ah Customer Site 1 Customer Site 2 Customer Provider Operator 1 802.1ag Operator 3 Operator 2 Entities at different levels have different responsibilities. For example, the lower level (operator) overlooks a subset of the network in detail and provides information about its status to its higher levels such as the provider level). 860 Configuring Connectivity Fault Management Higher levels have a broader, but less detailed, view of the network. As a result, a provider could include multiple operators, provided that the domains never intersect. The operator transparently passes frames from the customer and provider, and the customer does not see the operator frames. Multiple levels within a domain (say, operator) are supported for flexibility. What Entities Make Up a Maintenance Domain? Dot1ag defines three primary entities that make up the maintenance domain: Maintenance End Points (MEPs), Maintenance Intermediate Points (MIPs), and Maintenance Associations (MAs). MEPs, and MIPs MEPs and MIPs are software or sometimes hardware per-service entities where CFM functionalities are present. • MEPs define the boundary of a maintenance domain. They initiate and respond to CFM messages. MEPs prevent the leaking of CFM messages between domains (for example, among operators or between operators and customers). Each MEP has a configurable unique identifier (MEPID) in a maintenance domain. MEPs periodically issue Continuity Check Messages (CCM) to discover each other and issue SNMP traps to report connectivity losses or malformed or incorrect CCMs. A MEP can be defined as “down MEP” or an “up MEP”. A down MEPs reside in a bridge that transmits CFM PDUs towards, and receives them from, the direction of the LAN. An up MEP resides in a bridge that transmits CFM PDUs towards, and receives them from, the direction of the Bridge Relay Entity. NOTE: An entity at the boundary of maintenance domain that offers connectivity and other services to systems outside the domain is referred to as a Domain Service Access Point (DoSAP). A MEP is a type of DoSAP whose services relate to connectivity fault management. • MIPs are entities within a domain that enable the outer domain to achieve end-to-end connectivity checks. MIPs passively receive CFM messages and respond back to the originating MEP. Configuring Connectivity Fault Management 861 Figure 26-2 depicts two MEPs and the MIPs that connect them in a maintenance domain. Figure 26-2. Maintenance Endpoints and Intermediate Points Maintenance Associations An MA is a logical connection between one or more MEPs that enables monitoring a particular service instance. Each MA is associated with a unique SVLAN ID. An MA is identified by a maintenance association ID. All MEPs in the MA are assigned the maintenance identifier (MAID) for the association. An MD consists of one or more MAs at the same domain level. Figure 26-3 depicts one provider-level domain and two operator-level domains. Dot1ag operation for a service instance is indicated by the path that traverses the different domains to provide the end-to-end connectivity fault management for the service. 862 Configuring Connectivity Fault Management Figure 26-3. Provider View for Service Level OAM What is the Administrator’s Role? On the switch, the administrator configures the customer-level maintenance domains, associations, and endpoints used to participate in Dot1ag services with other switches connected through the provider network. The Administrator can also use utilities to troubleshoot connectivity faults when reported via SNMP traps. All the domains within the customer domain should use different domain levels. Configuration Tasks The administrator defines the maintenance domains by configuring the domain level (from 0–7) and a name. For each domain, the administrator defines maintenance associations that are specified by a SVLAN ID and an MA name. Then the administrator defines the switch ports that serve as MEPs for a service instance and as MIPs within a domain. Configuring Connectivity Fault Management 863 Troubleshooting Tasks In the event of a connectivity loss between MEPs, the administrator can perform path discovery, similar to traceroute, from one MEP to any MEP or MIP in a maintenance domain using Link Trace Messages (LTMs). The connectivity loss is narrowed down using path discovery and is verified using Loop-back Messages (LBMs), which are similar to ping operations in IP networks. Default Dot1ag Values Dot1ag service are disabled by default and no maintenance domains, associations, or endpoints are configured by default. Table 26-1 shows the global default values for Dot1ag. Table 26-1. Dot1ag Global Defaults Parameter Default Value CFM Admin Mode Disabled Archive Hold Time 600 seconds When you configure an association between a VLAN and a maintenance domain, the following default value applies: Table 26-2. MA Configuration Defaults Parameter Default Value Continuity Check Message (CCM) Interval 1 second When you associate endpoints with SVLAN IDs, the following default values apply and are configurable: Table 26-3. MEP Configuration Defaults Parameter Default Value MEP Active False Continuity Check Interval (CCI) Enabled True 864 Configuring Connectivity Fault Management Configuring Dot1ag (Web) This section provides information about the OpenManage Switch Administrator pages for configuring and monitoring Dot1ag features on a Dell Networking N2000, N3000, and N4000 series switches. For details about the fields on a page, click at the top of the page. Dot1ag Global Configuration Use the Global Configuration page to enable and disable the Dot1ag admin mode and to configure the time after which inactive RMEP messages are removed from the MEP database. To display the page, click Switching → Dot1ag → Global Configuration in the tree view. Figure 26-4. Dot1ag Global Configuration Dot1ag MD Configuration Use the MD Configuration page to configure maintenance domain levels and names. To display the page, click Switching → Dot1ag → MD Configuration in the tree view. Configuring Connectivity Fault Management 865 Figure 26-5. Dot1ag MD Configuration Dot1ag MA Configuration Use the MA Configuration page to associate a maintenance domain level with one or more VLAN ID, provide a name for each maintenance association (MA), and to set the interval between continuity check messages sent by MEPs for the MA. To display the page, click Switching → Dot1ag → MA Configuration in the tree view. Figure 26-6. Dot1ag MA Configuration 866 Configuring Connectivity Fault Management To add an MA, click the Add link at the top of the page. Dot1ag MEP Configuration Use the MEP Configuration page to define switch ports as Management End Points. MEPs are configured per domain and per VLAN. To display the page, click Switching → Dot1ag → MEP Configuration in the tree view. Figure 26-7. Dot1ag MEP Configuration Configuring Connectivity Fault Management 867 To add a MEP, click the Add link at the top of the page. A VLAN must be associated with the selected domain before you configure a MEP to be used within an MA (see the MA Configuration page). Dot1ag MIP Configuration Use the MIP Configuration page to define a switch port as an intermediate bridge for a selected domain. To display the page, click Switching → Dot1ag → MIP Configuration in the tree view. Figure 26-8. Dot1ag MIP Configuration 868 Configuring Connectivity Fault Management Dot1ag RMEP Summary Use the RMEP Summary page to view information on remote MEPs that the switch has learned through CFM PDU exchanges with MEPs on the switch. To display the page, click Switching → Dot1ag → RMEP Summary in the tree view. Figure 26-9. Dot1ag RMEP Summary Configuring Connectivity Fault Management 869 Dot1ag L2 Ping Use the L2 Ping page to generate a loopback message from a specified MEP. The MEP can be identified by the MEP ID or by its MAC address. To display the page, click Switching → Dot1ag → L2 Ping in the tree view. Figure 26-10. Dot1ag L2 Ping Dot1ag L2 Traceroute Use the L2 Traceroute page to generate a Link Trace message from a specified MEP. The MEP can be specified by the MAC address, or by the remote MEP ID. To display the page, click Switching → Dot1ag → L2 Traceroute in the tree view. 870 Configuring Connectivity Fault Management Figure 26-11. Dot1ag L2 Traceroute Dot1ag L2 Traceroute Cache Use the L2 Traceroute Cache page to view link traces retained in the link trace database. To display the page, click Switching → Dot1ag → L2 Traceroute Cache in the tree view. Figure 26-12. Dot1ag L2 Traceroute Cache Configuring Connectivity Fault Management 871 Dot1ag Statistics Use the Statistics page to view Dot1ag information for a selected domain and VLAN ID. To display the page, click Switching → Dot1ag → Statistics in the tree view. Figure 26-13. 872 Dot1ag Statistics Configuring Connectivity Fault Management Configuring Dot1ag (CLI) This section provides information about the commands you use to configure Dot1ag settings on the switch. For more information about the commands, see the Dell Networking N2000, N3000, and N4000 Series Switches CLI Reference Guide at support.dell.com/manuals. Configuring Dot1ag Global Settings and Creating Domains Beginning in Privileged Exec mode, use the following commands to configure CFM settings and to view global status and domain information. CLI Command Description configure Enter global configuration mode. ethernet cfm enable Enables connectivity fault management services. ethernet cfm mep archivehold-time time Set the time interval (range: 1–65535 seconds) after which inactive RMEPs are removed. ethernet cfm cc level level vlan Configure the Continuity Check Message (CCM) vlan-id interval {1 | 10 | 60 | transmit interval for the specified VLAN. 600} ethernet cfm domain name level level Create a maintenance domain (MD) by assigning a name and level (0–7), and enter Maintenance Domain Config mode for that MD. service name vlan vlan-id Create a maintenance association (MA) within the current MD by associating it with a VLAN and naming the association (as a service instance). exit Exit to privileged Exec Mode show ethernet cfm domain brief Display the configured parameters in the Maintenance Domain. Configuring Connectivity Fault Management 873 Configuring MEP Information Beginning in Privileged Exec mode, use the following commands to configure the mode and view related settings. CLI Command Description configure Enter global configuration mode. interface interface Enter Interface Config mode for the specified interface, where interface is replaced by gigabitethernet unit/slot/port, or tengigabitethernet unit/slot/port. ethernet cfm mep enable level Define the port as a maintenance endpoint (MEP) level vlan vlan-id mpid mep-id and associate it with an SVLAN in a domain. When the MEP is enabled, it will generate CCM messages. ethernet cfm mep level level direction {up | down} mpid mep-id vlan vlan-id Enable a MEP at the specified level and direction. ethernet cfm mep active Set the administrative state of the MEP to active. ethernet cfm mip level level Create a MIP at the specified level on the interface. exit Exit to privileged Exec Mode show ethernet cfm maintenance–points Add the keywords local domain, local interface, local level, remote domain, or remote level to show information on local or remote endpoints. show ethernet cfm statistics Display statistics per MEP. 874 Configuring Connectivity Fault Management Dot1ag Ping and Traceroute Beginning in Privileged Exec mode, use the following commands to help identify and troubleshoot Ethernet CFM settings. CLI Command Description ping ethernet cfm mac mac- addr Generate a loopback message from the MEP with the specified MAC address. ping ethernet cfm remote–mpid mep-id Generate a loopback message from the MEP with the specified MEP ID. traceroute ethernet cfm mac mac-addr Generate a Link Trace message from the MEP with the specified MAC address. traceroute ethernet cfm remote–mpid mep-id Generate a Link Trace message from the MEP with the specified MEP ID. show ethernet cfm traceroute–cache Show the link trace database. Configuring Connectivity Fault Management 875 Dot1ag Configuration Example In the following example, the switch at the customer site is part of a Metro Ethernet network that is bridged to remote sites through a provider network. A service VLAN (SVID 200) identifies a particular set of customer traffic on the provider network. Figure 26-14. Dot1ag Configuration for a Metro Ethernet Customer Network To configure the switch: 1 Enable CFM globally on the switch, and then create a level-6 management domain named CustDom for end-to-end CFM on the Metro Ethernet network. VLAN 200 is associated with this domain. console#config console(config)#ethernet cfm enable console(config)#ethernet cfm domain CustDom level 6 console(config-cfm-mdomain)#service vlan vlan 200 console(config-cfm-mdomain)#exit 876 Configuring Connectivity Fault Management 2 Configure port 1/0/5 as an MEP for service VLAN 200 so that the port can exchange CFM PDUs with its counterpart MEPs on the customer network. The port is first configured as a MEP with MEP ID 20 on domain level 6 for VLAN 200. Then the port is enabled and activated as a MEP. console(config)#interface gigabitethernet 1/0/5 console(config-if-Gi1/0/5)#ethernet cfm mep level 6 direction down mpid 20 vlan 200 console(config-if-Gi1/0/5)#ethernet cfm mep enabled level 6 vlan 200 mpid 20 console(config-if-Gi1/0/5)#ethernet cfm mep active level 6 vlan 200 mpid 20 console(config-if-Gi1/0/5)#exit 3 On an intermediate switch, configure the MIP for the customer domain and enable CFM services on the CustDom domain to include local network devices. Configuring Connectivity Fault Management 877 878 Configuring Connectivity Fault Management 27 Snooping and Inspecting Traffic This chapter describes Dynamic Host Configuration Protocol (DHCP) Snooping, IP Source Guard (IPSG), and Dynamic ARP Inspection (DAI), which are layer 2 security features that examine traffic to help prevent accidental and malicious attacks on the switch or network. The topics covered in this chapter include: • Traffic Snooping and Inspection Overview • Default Traffic Snooping and Inspection Values • Configuring Traffic Snooping and Inspection (Web) • Configuring Traffic Snooping and Inspection (CLI) • Traffic Snooping and Inspection Configuration Examples Traffic Snooping and Inspection Overview DHCP Snooping is a security feature that monitors DHCP messages between a DHCP client and DHCP server to filter harmful DHCP messages and to build a bindings database. The IPSG and DAI features use the DHCP Snooping bindings database to help enforce switch and network security. IP Source Guard allows the switch to drop incoming packets that do not match a binding in the bindings database. Dynamic ARP Inspection allows the switch to drop ARP packets whose sender MAC address and sender IP address do not match an entry in the DHCP snooping bindings database. DHCP Snooping and IPSG are supported for both IPv4 and IPv6. DAI is supported for IPv4 only, as IPv6 does not use ARP. Snooping and Inspecting Traffic 879 What Is DHCP Snooping? Dynamic Host Configuration Protocol (DHCP) Snooping is a security feature that monitors DHCP messages between a DHCP client and DHCP server to accomplish the following tasks: • Filter harmful DHCP messages • Build a bindings database with entries that consist of the following information: • MAC address • IP address • VLAN ID • Client port Entries in the bindings database are considered to be authorized network clients. DHCP snooping can be enabled on VLANs, and the trust status (trusted or untrusted) is specified on individual physical ports or LAGS that are members of a VLAN. When a port or LAG is configured as untrusted, it could potentially be used to launch a network attack. DHCP servers must be reached through trusted ports. DHCP snooping enforces the following security rules: 880 • DHCP packets from a DHCP server (DHCPOFFER, DHCPACK, DHCPNAK, DHCPRELEASEQUERY) are dropped if they are received on an untrusted port. • DHCPRELEASE and DHCPDECLINE messages are dropped if the MAC addresses in the snooping database, but the binding's interface is other than the interface where the message was received. • On untrusted interfaces, the switch drops DHCP packets with a source MAC address that does not match the client hardware address. This is a configurable option. Snooping and Inspecting Traffic How Is the DHCP Snooping Bindings Database Populated? The DHCP snooping application uses DHCP messages to build and maintain the binding’s database. DHCP snooping creates a tentative binding from DHCP DISCOVER and REQUEST messages. Tentative bindings tie a client to a port (the port where the DHCP client message was received). Tentative bindings are completed when DHCP snooping learns the client’s IP address from a DHCP ACK message on a trusted port. DHCP snooping removes bindings in response to DECLINE, RELEASE, and NACK messages. The DHCP snooping application ignores the ACK messages as a reply to the DHCP Inform messages received on trusted ports. You can also enter static bindings into the binding database. When a switch learns of new bindings or loses bindings, the switch immediately updates the entries in the database. The switch also updates the entries in the binding file. The frequency at which the file is updated is based on a configurable delay, and the updates are batched. If the absolute lease time of the snooping database entry expires, that entry is removed. Make sure the system time is consistent across the reboots. Otherwise, the snooping entries will not expire properly. If a host sends a DHCP release while the switch is rebooting, when the switch receives the DHCP discovery or request, the client’s binding goes to the tentative binding as shown in Figure 27-1. Figure 27-1. DHCP Binding No Binding Discover Request Tentative Binding Release NACK Decline NACK Discover ACK Complete Binding The binding database includes data for clients only on untrusted ports. Snooping and Inspecting Traffic 881 DHCP Snooping and VLANs DHCP snooping forwards valid DHCP client messages received on nonrouting VLANs. The message is forwarded on all trusted interfaces in the VLAN. DHCP snooping can be configured on switching VLANs and routing VLANs. When a DHCP packet is received on a routing VLAN, the DHCP snooping application applies its filtering rules and updates the bindings database. If a client message passes filtering rules, the message is placed into the software forwarding path where it may be processed by the DHCP relay agent, the local DHCP server, or forwarded as an IP packet. DHCP Snooping Logging and Rate Limits The DHCP snooping application processes incoming DHCP messages. For DHCPRELEASE and DHCPDECLINE messages, the application compares the receive interface and VLAN with the client interface and VLAN in the bindings database. If the interfaces do not match, the application logs the event and drops the message. For valid client messages, DHCP snooping compares the source MAC address to the DHCP client hardware address. When there is a mismatch, DHCP snooping drops the packet and generates a log message if logging of invalid packets is enabled. If DHCP relay co-exists with DHCP snooping, DHCP client messages are sent to DHCP relay for further processing. To prevent DHCP packets from being used as a DoS attack when DHCP snooping is enabled, the snooping application enforces a rate limit for DHCP packets received on interfaces. DHCP rate limiting can be configured on both trused and untrusted interfaces. DHCP snooping monitors the receive rate on each interface separately. If the receive rate exceeds a configurable limit, DHCP snooping diagnostically disables the interface. Administrative intervention is necessary to enable the port, either by using the no shutdown command in Interface Config mode or on the Switching → Ports → Port Configuration page. Use the ip dhcp snooping limit none command to disable diagnostic disabling of the port due to DHCP snooping. 882 Snooping and Inspecting Traffic What Is IP Source Guard? IPSG is a security feature that filters IP packets based on source ID. This feature helps protect the network from attacks that use IP address spoofing to compromise or overwhelm the network. The source ID may be either the source IP address or a {source IP address, source MAC address} pair. You can configure: • Whether enforcement includes the source MAC address • Static authorized source IDs The DHCP snooping bindings database and static IPSG entries identify authorized source IDs. IPSG can be enabled on physical and LAG ports. If you enable IPSG on a port where DHCP snooping is disabled or where DHCP snooping is enabled but the port is trusted, all IP traffic received on that port is dropped depending on the admin-configured IPSG entries. IPSG and Port Security IPSG interacts with port security, also known as port MAC locking, (see "Port Security (Port-MAC Locking)" on page 539) to enforce the source MAC address. Port security controls source MAC address learning in the layer 2 forwarding database (MAC address table). When a frame is received with a previously unlearned source MAC address, port security queries the IPSG feature to determine whether the MAC address belongs to a valid binding. If IPSG is disabled on the ingress port, IPSG replies that the MAC is valid. If IPSG is enabled on the ingress port, IPSG checks the bindings database. If the MAC address is in the bindings database and the binding matches the VLAN the frame was received on, IPSG replies that the MAC is valid. If the MAC is not in the bindings database, IPSG informs port security that the frame is a security violation. In the case of an IPSG violation, port security takes whatever action it normally takes upon receipt of an unauthorized frame. Port security limits the number of MAC addresses to a configured maximum. If the limit n is less than the number of stations m in the bindings database, port security allows only n stations to use the port. If n > m, port security allows only the stations in the bindings database. For information about configuring the Port Security feature, see "Configuring Port and System Security" on page 503. Snooping and Inspecting Traffic 883 What is Dynamic ARP Inspection? Dynamic ARP Inspection (DAI) is a security feature that rejects invalid and malicious ARP packets. DAI prevents a class of man-in-the-middle attacks where an unfriendly station intercepts traffic for other stations by poisoning the ARP caches of its unsuspecting neighbors. The malicious attacker sends ARP requests or responses mapping another station’s IP address to its own MAC address. When DAI is enabled, the switch drops ARP packets whose sender MAC address and sender IP address do not match an entry in the DHCP snooping bindings database. You can optionally configure additional ARP packet validation. When DAI is enabled on a VLAN, DAI is enabled on the interfaces (physical ports or LAGs) that are members of that VLAN. Individual interfaces are configured as trusted or untrusted. The trust configuration for DAI is independent of the trust configuration for DHCP snooping. Optional DAI Features If the network administrator has configured the option, DAI verifies that the sender MAC address equals the source MAC address in the Ethernet header. There is a configurable option to verify that the target MAC address equals the destination MAC address in the Ethernet header. This check applies only to ARP responses, since the target MAC address is unspecified in ARP requests. You can also enable IP address checking. When this option is enabled, DAI drops ARP packets with an invalid IP address. The following IP addresses are considered invalid: • 0.0.0.0 • 255.255.255.255 • all IP multicast addresses • all class E addresses (240.0.0.0/4) • loopback addresses (in the range 127.0.0.0/8) DAI can also be configured to rate-limit ARP requests on untrusted interfaces. If the configured rate is exceeded, DAI diagnostically disables the port on which the rate limit was exceeded. Use the no shutdown command to 884 Snooping and Inspecting Traffic re-enable the port. DAI rate limiting cannot be enabled on trusted interfaces. Use the no ip arp inspection limit command to disable diagnostic disabling of untrused ports due to DAI. Why Is Traffic Snooping and Inspection Necessary? DHCP Snooping, IPSG, and DAI are security features that can help protect the switch and the network against various types of accidental or malicious attacks. It might be a good idea to enable these features on ports that provide network access to hosts that are in physically unsecured locations or if network users connect nonstandard hosts to the network. For example, if an employee unknowingly connects a workstation to the network that has a DHCP server, and the DHCP server is enabled, hosts that attempt to acquire network information from the legitimate network DHCP server might obtain incorrect information from the rogue DHCP server. However, if the workstation with the rogue DHCP server is connected to a port that is configured as untrusted and is a member of a DHCP Snoopingenabled VLAN, the port discards the DHCP server messages. Default Traffic Snooping and Inspection Values DHCP snooping is disabled globally and on all VLANs by default. Ports are untrusted by default. Table 27-1. Traffic Snooping Defaults Parameter Default Value DHCP snooping mode Disabled DHCP snooping VLAN mode Disabled on all VLANs Interface trust state Disabled (untrusted) DHCP logging invalid packets Disabled DHCP snooping rate limit 15 packets per second DHCP snooping burst interval 1 second DHCP snooping binding database storage Local DHCP snooping binding database write delay 300 seconds Snooping and Inspecting Traffic 885 Table 27-1. Traffic Snooping Defaults (Continued) Parameter Default Value Static DHCP bindings None configured IPSG mode Disabled on all interfaces IPSG port security Disabled on all interfaces Static IPSG bindings None configured DAI validate source MAC Disabled DAI validate destination MAC Disabled DAI validate IP Disabled DAI trust state Disabled (untrusted) DAI Rate limit Disabled DAI Burst interval 1 second DAI mode Disabled on all VLANs DAI logging invalid packets Disabled DAI ARP ACL None configured DAI Static flag Disabled (validation by ARP ACL and DHCP snooping binding database) 886 Snooping and Inspecting Traffic Configuring Traffic Snooping and Inspection (Web) This section provides information about the OpenManage Switch Administrator pages for configuring and monitoring DHCP snooping, IPSG, and DAI features on a Dell Networking N2000, N3000, and N4000 series switches. For details about the fields on a page, click at the top of the page. DHCP Snooping Configuration Use the DHCP Snooping Configuration page to control the DHCP Snooping mode on the switch and to specify whether the sender MAC Address for DHCP Snooping must be validated. To access the DHCP Snooping Configuration page, click Switching → DHCP Snooping → Global Configuration in the navigation panel. Figure 27-2. DHCP Snooping Configuration Snooping and Inspecting Traffic 887 DHCP Snooping Interface Configuration Use the DHCP Snooping Interface Configuration page to configure the DHCP Snooping settings on individual ports and LAGs. To access the DHCP Snooping Interface Configuration page, click Switching → DHCP Snooping → Interface Configuration in the navigation panel. Figure 27-3. DHCP Snooping Interface Configuration 888 Snooping and Inspecting Traffic To view a summary of the DHCP snooping configuration for all interfaces, click Show All. Figure 27-4. DHCP Snooping Interface Configuration Summary Snooping and Inspecting Traffic 889 DHCP Snooping VLAN Configuration Use the DHCP Snooping VLAN Configuration page to control the DHCP snooping mode on each VLAN. To access the DHCP Snooping VLAN Configuration page, click Switching → DHCP Snooping → VLAN Configuration in the navigation panel. Figure 27-5. DHCP Snooping VLAN Configuration To view a summary of the DHCP snooping status for all VLANs, click Show All. Figure 27-6. DHCP Snooping VLAN Configuration Summary 890 Snooping and Inspecting Traffic DHCP Snooping Persistent Configuration Use the DHCP Snooping Persistent Configuration page to configure the persistent location of the DHCP snooping database. The bindings database can be stored locally on the switch or on a remote system somewhere else in the network. The switch must be able to reach the IP address of the remote system to send bindings to a remote database. To access the DHCP Snooping Persistent Configuration page, click Switching → DHCP Snooping → Persistent Configuration in the navigation panel. Figure 27-7. DHCP Snooping Persistent Configuration Snooping and Inspecting Traffic 891 DHCP Snooping Static Bindings Configuration Use the DHCP Snooping Static Bindings Configuration page to add static DHCP bindings to the binding database. To access the DHCP Snooping Static Bindings Configuration page, click Switching → DHCP Snooping → Static Bindings Configuration in the navigation panel. Figure 27-8. DHCP Snooping Static Bindings Configuration To view a summary of the DHCP snooping status for all VLANs, click Show All. Figure 27-9. DHCP Snooping Static Bindings Summary To remove a static binding, select the Remove checkbox associated with the binding and click Apply. 892 Snooping and Inspecting Traffic DHCP Snooping Dynamic Bindings Summary The DHCP Snooping Dynamic Bindings Summary lists all the DHCP snooping dynamic binding entries learned on the switch ports. To access the DHCP Snooping Dynamic Bindings Summary page, click Switching → DHCP Snooping → Dynamic Bindings Summary in the navigation panel. Figure 27-10. DHCP Snooping Dynamic Bindings Summary Snooping and Inspecting Traffic 893 DHCP Snooping Statistics The DHCP Snooping Statistics page displays DHCP snooping interface statistics. To access the DHCP Snooping Statistics page, click Switching → DHCP Snooping → Statistics in the navigation panel. Figure 27-11. 894 DHCP Snooping Statistics Snooping and Inspecting Traffic IPSG Interface Configuration Use the IPSG Interface Configuration page to configure IPSG on an interface. To access the IPSG Interface Configuration page, click Switching → IP Source Guard → IPSG Interface Configuration in the navigation panel. Figure 27-12. IPSG Interface Configuration IPSG Binding Configuration Use the IPSG Binding Configuration page displays DHCP snooping interface statistics. To access the IPSG Binding Configuration page, click Switching → IP Source Guard → IPSG Binding Configuration in the navigation panel. Figure 27-13. IPSG Binding Configuration Snooping and Inspecting Traffic 895 IPSG Binding Summary The IPSG Binding Summary page displays the IPSG Static binding list and IPSG dynamic binding list (the static bindings configured in Binding configuration page). To access the IPSG Binding Summary page, click Switching → IP Source Guard → IPSG Binding Summary in the navigation panel. Figure 27-14. 896 IPSG Binding Summary Snooping and Inspecting Traffic DAI Global Configuration Use the DAI Configuration page to configure global DAI settings. To display the DAI Configuration page, click Switching → Dynamic ARP Inspection → Global Configuration in the navigation panel. Figure 27-15. Dynamic ARP Inspection Global Configuration Snooping and Inspecting Traffic 897 DAI Interface Configuration Use the DAI Interface Configuration page to select the DAI Interface for which information is to be displayed or configured. To display the DAI Interface Configuration page, click Switching → Dynamic ARP Inspection → Interface Configuration in the navigation panel. Figure 27-16. Dynamic ARP Inspection Interface Configuration To view a summary of the DAI status for all interfaces, click Show All. 898 Snooping and Inspecting Traffic Figure 27-17. DAI Interface Configuration Summary Snooping and Inspecting Traffic 899 DAI VLAN Configuration Use the DAI VLAN Configuration page to select the VLANs for which information is to be displayed or configured. To display the DAI VLAN Configuration page, click Switching → Dynamic ARP Inspection → VLAN Configuration in the navigation panel. Figure 27-18. Dynamic ARP Inspection VLAN Configuration To view a summary of the DAI status for all VLANs, click Show All. Figure 27-19. 900 Dynamic ARP Inspection VLAN Configuration Summary Snooping and Inspecting Traffic DAI ACL Configuration Use the DAI ACL Configuration page to add or remove ARP ACLs. To display the DAI ACL Configuration page, click Switching → Dynamic ARP Inspection → ACL Configuration in the navigation panel. Figure 27-20. Dynamic ARP Inspection ACL Configuration To view a summary of the ARP ACLs that have been created, click Show All. Figure 27-21. Dynamic ARP Inspection ACL Summary To remove an ARP ACL, select the Remove checkbox associated with the ACL and click Apply. DAI ACL Rule Configuration Use the DAI ARP ACL Rule Configuration page to add or remove DAI ARP ACL Rules. To display the DAI ARP ACL Rule Configuration page, click Switching → Dynamic ARP Inspection → ACL Rule Configuration in the navigation panel. Snooping and Inspecting Traffic 901 Figure 27-22. Dynamic ARP Inspection Rule Configuration To view a summary of the ARP ACL rules that have been created, click Show All. Figure 27-23. Dynamic ARP Inspection ACL Rule Summary To remove an ARP ACL rule, select the Remove checkbox associated with the rule and click Apply. DAI Statistics Use the DAI Statistics page to display the statistics per VLAN. To display the DAI Statistics page, click Switching → Dynamic ARP Inspection → Statistics in the navigation panel. 902 Snooping and Inspecting Traffic Figure 27-24. Dynamic ARP Inspection Statistics Snooping and Inspecting Traffic 903 Configuring Traffic Snooping and Inspection (CLI) This section provides information about the commands you use to configure DHCP snooping, IPSG, and DAI settings on the switch. For more information about the commands, see the Dell Networking N2000, N3000, and N4000 Series Switches CLI Reference Guide at support.dell.com/manuals. Configuring DHCP Snooping Beginning in Privileged EXEC mode, use the following commands to configure and view DHCP snooping settings. Command Purpose configure Enter global configuration mode. ip dhcp snooping Enable DHCP snooping on the switch. ipv6 dhcp snooping Enable IPv6 DHCP snooping on the switch. ip dhcp snooping verify Enable the verification of the source MAC address with mac-address the client MAC address in the received DHCP message. ip dhcp snooping loginvalid Enable the logging of DHCP messages filtered by the DHCP Snooping application. ip dhcp snooping binding mac-address vlan vlan-id ip-address interface interface Configure a static binding in the DHCP snooping static bindings database. • mac-address —The client's MAC address. • vlan-id —The number of the VLAN the client is authorized to use. • ip-address —The IP address of the client. • interface —The interface on which the client is authorized. The form is unit/port. ip dhcp snooping database {local | tftp://hostIP/filename} Configure the persistent storage location of the DHCP snooping database. • hostIP —The IP address of the remote host. • filename —The name of the file for the database on the remote host. 904 Snooping and Inspecting Traffic Command Purpose ip dhcp snooping database write-delay Configure the interval, in seconds, at which the DHCP Snooping database will be stored in persistent storage. The number of seconds can range from 15–86400. ip dhcp snooping limit {none | rate rate [burst interval seconds]} Configure the maximum rate of DHCP messages allowed on the switch at any given time. seconds • rate —The maximum number of packets per second allowed (Range: 0–300 pps). • seconds —The time allowed for a burst (Range: 1–15 seconds). interface interface Enter interface configuration mode for the specified port or LAG. The interface variable includes the interface type and number, for example tengigabitethernet 1/0/3. For a LAG, the interface type is port-channel. You can also specify a range of ports with the interface range command, for example, interface range tengigabitethernet 1/0/8-12 configures interfaces 8, 9, 10, 11, and 12. ip dhcp snooping trust Configure the interface (or range of interfaces) as a trusted port. DHCP server messages are not filtered on trusted ports. exit Exit to Global Configuration mode. vlan id interface [range] vlan Enter interface configuration mode for the specified VLAN or range of VLANs. CTRL + Z Exit to Privileged EXEC mode. show ip dhcp snooping [interfaces] View the DHCP snooping global and per port configuration. show ip dhcp snooping binding [{static | dynamic}] [interface port] [vlan vlan-id] View the entries in the DHCP snooping bindings database. show ip dhcp snooping database View information about the persistent database configuration. show ip dhcp snooping statistics View the DHCP snooping statistics. Snooping and Inspecting Traffic 905 Command Purpose clear ip dhcp snooping statistics Reset the DHCP snooping statistics to zero. Configuring IP Source Guard Beginning in Privileged EXEC mode, use the following commands to configure IPSG settings on the switch. Command Purpose configure Enter global configuration mode. interface interface Enter interface configuration mode for the specified port or LAG. The interface variable includes the interface type and number, for example tengigabitethernet 1/0/3. For a LAG, the interface type is port-channel. You can also specify a range of ports with the interface range command, for example, interface range tengigabitethernet 1/0/8-12 configures interfaces 8, 9, 10, 11, and 12. ip verify source [portsecurity] and ipv6 verify source [portsecurity] Enable IPSG on the port or LAG to prevent packet forwarding if the source IP address in the packet is not in the DHCP snooping binding database. Use the optional port-security keyword to also prevent packet forwarding if the sender MAC address is not in forwarding database table or the DHCP snooping binding database. NOTE: To enforce filtering based on the source MAC address, port security must also be enabled on the interface by using the port security command in Interface Configuration mode. exit Exit to Global Config mode. Configure a static binding for IPSG. ip verify binding mac_addr vlan vlan_id ipaddr interface interface and ipv6 verify binding mac_addr vlan vlan_id ipaddr interface interface 906 Snooping and Inspecting Traffic Command Purpose exit Exit to Privileged EXEC mode. show ip verify interface View IPSG parameters for a specific port or LAG. The interface parameter includes the interface type (gigabitethernet, tengigabitethernet, or port-channel) and number. show ip verify source [interface interface] View IPSG bindings configured on the switch or on a specific port or LAG. show ip source binding View IPSG bindings. interface Configuring Dynamic ARP Inspection Beginning in Privileged EXEC mode, use the following commands to configure DAI settings on the switch. Command Purpose configure Enter global configuration mode. ip arp inspection vlan vlan-range [logging] Enable Dynamic ARP Inspection on a single VLAN or a range of VLANs. Use the logging keyword to enable logging of invalid packets. ip arp inspection Enable additional validation checks like source MAC validate {[src-mac] [dst- address validation, destination MAC address validation, or mac] [ip]} IP address validation on the received ARP packets. Each command overrides the configuration of the previous command. For example, if a command enables source MAC address and destination validations and a second command enables IP address validation only, the source MAC address and destination MAC address validations are disabled as a result of the second command. • src-mac—For validating the source MAC address of an ARP packet. • dst-mac—For validating the destination MAC address of an ARP packet. • ip—For validating the IP address of an ARP packet. Snooping and Inspecting Traffic 907 Command Purpose arp access-list acl-name Create an ARP ACL with the specified name (1–31 characters) and enter ARP Access-list Configuration mode for the ACL. permit ip host sender-ip mac host sender-mac Configure a rule for a valid IP address and MAC address combination used in ARP packet validation. • sender-ip — Valid IP address used by a host. • sender-mac —Valid MAC address in combination with the above sender-ip used by a host. exit Exit to Global Config mode. ip arp inspection filter Configure the ARP ACL to be used for a single VLAN or a acl-name vlan vlan-range range of VLANs to filter invalid ARP packets. [static] Use the static keyword to indicate that packets that do not match a permit statement are dropped without consulting the DHCP snooping bindings. interface interface Enter interface configuration mode for the specified port or LAG. The interface variable includes the interface type and number, for example tengigabitethernet 1/0/3. For a LAG, the interface type is port-channel. You can also specify a range of ports with the interface range command, for example, interface range tengigabitethernet 1/0/8-12 configures interfaces 8, 9, 10, 11, and 12. ip arp inspection limit {none | rate pps [burst interval seconds ]} Configure the rate limit and burst interval values for an interface.Use the keyword none to specify that the interface is not rate limited for Dynamic ARP Inspection. • none — To set no rate limit. • pps — Packets per second (Range: 0–300). • seconds — The number of seconds (Range: 1–15). ip arp inspection trust Specify that the interface as trusted for Dynamic ARP Inspection. CTRL + Z Exit to Privileged EXEC mode. show ip arp inspection interfaces [interface] View the Dynamic ARP Inspection configuration on all the DAI-enabled interfaces or for the specified interface. 908 Snooping and Inspecting Traffic Command Purpose show ip arp inspection vlan [vlan-range ] View the Dynamic ARP Inspection configuration on the specified VLAN(s). This command also displays the global configuration values for source MAC validation, destination MAC validation and invalid IP validation. show ip arp inspection statistics [vlan vlanrange] View the statistics of the ARP packets processed by Dynamic ARP Inspection for the switch or for the specified VLAN(s). show arp access-list [acl- View all configured ARP ACL and their rules, or use the ACL name to view information about that ARP ACL only. name] Snooping and Inspecting Traffic 909 Traffic Snooping and Inspection Configuration Examples This section contains the following examples: • Configuring DHCP Snooping • Configuring IPSG Configuring DHCP Snooping In this example, DHCP snooping is enabled on VLAN 100. Ports 1-20 connect end users to the network and are members of VLAN 100. These ports are configured to limit the maximum number of DHCP packets with a rate limit of 100 packets per second. LAG 1, which is also a member of VLAN 100 and contains ports 21-24, is the trunk port that connects the switch to the data center, so it is configured as a trusted port. Figure 27-25. DHCP Snooping Configuration Topology The commands in this example also enforce rate limiting and remote storage of the bindings database. The switch has a limited amount of storage space in NVRAM and flash memory, so the administrator specifies that the DHCP snooping bindings database is stored on an external TFTP server. 910 Snooping and Inspecting Traffic To configure the switch: 1 Enable DHCP snooping on VLAN 100. console#config console(config)#ip dhcp snooping vlan 100 2 Configure LAG 1, which includes ports 21-24, as a trusted port. All other interfaces are untrusted by default. console(config)#interface port-channel 1 console(config-if-Po1)#ip dhcp snooping trust console(config-if-Po1)#exit 3 Enter interface configuration mode for all untrusted interfaces (ports 120) and limit the number of DHCP packets that an interface can receive to 100 packets per second. LAG 1 is a trusted port and keeps the default value for rate limiting (unlimited). console(config)#interface range gi1/0/1-20 console(config-if)#ip dhcp snooping limit rate 100 console(config-if)#exit 4 Specify that the DHCP snooping database is to be stored remotely in a file called dsDb.txt on a TFTP server with and IP address of 10.131.11.1. console(config)#ip dhcp snooping database tftp://10.131.11.1/dsDb.txt console(config)#exit 5 Enable DHCP snooping for the switch console(config)#ip dhcp snooping 6 View DHCP snooping information. console#show ip dhcp snooping DHCP snooping is Enabled DHCP snooping source MAC verification is enabled DHCP snooping is enabled on the following VLANs: 100 Interface ----------- Trusted ---------- Log Invalid Pkts ---------------- Snooping and Inspecting Traffic 911 Configuring IPSG This example builds on the previous example and uses the same topology shown in Figure 27-25. In this configuration example, IP source guard is enabled on ports 1-20. DHCP snooping must also be enabled on these ports. Additionally, because the ports use IP source guard with source IP and MAC address filtering, port security must be enabled on the ports as well. To configure the switch: 1 Enter interface configuration mode for the host ports and enable IPSG. console(config)#interface range gi1/0/1-20 console(config-if)#ip verify source port-security 2 Enable port security on the ports. console(config-if)#port security 3 View IPSG information. console#show ip verify source Interface Filter --------- ------Gi1/0/1 ip-mac Gi1/0/2 ip-mac Gi1/0/3 ip-mac Gi1/0/4 ip-mac Gi1/0/5 ip-mac --More-- or (q)uit 912 IP Address ---------192.168.3.45 192.168.3.40 192.168.3.33 192.168.3.18 192.168.3.49 Snooping and Inspecting Traffic MAC Address Vlan 00:1C:23:55:D4:8E 00:1C:23:12:44:B6 00:1C:23:AA:B8:01 00:1C:23:67:D3:CC 00:1C:23:55:1B:6E 100 100 100 100 100 28 Configuring Link Aggregation This chapter describes how to create and configure link aggregation groups (LAGs), which are also known as port-channels. The topics covered in this chapter include: • Link Aggregation • Multi-Switch LAG (MLAG) Link Aggregation Overview Link Aggregation allows one or more full-duplex Ethernet links of the same speed to be aggregated together to form a LAG. This allows the switch to treat the LAG as if it is a single link. The Dell Networking series switches support industry-standard LAGs that adhere to the IEEE 802.3ad specification. Assignment of interfaces to dynamic LAGs is based on a maximum of 144 interfaces assigned to dynamic LAGs, a maximum of 72 dynamic LAGs and a maximum of 8 interfaces per dynamic LAG. For example, 72 LAGs may be assigned 2 interfaces each, or 18 LAGs may be assigned 8 interfaces each. Each LAG can consist of up to eight 1 Gbps or eight 10 Gbps ports (or even eight 40 Gbps interfaces). When eight Gigabit Ethernet ports are configured as a LAG, the maximum bandwidth for the single, logical interface is 8 Gbps, and when eight 10 Gbps ports are configured as a LAG, the maximum bandwidth for the single, logical interface is 80 Gbps. Figure 28-1 shows an example of a switch in the wiring closet connected to a switch in the data center by a LAG that consists of four physical 10 Gbps links. The LAG provides full-duplex bandwidth of 40 Gbps between the two switches. Configuring Link Aggregation 913 Figure 28-1. LAG Configuration LAGs can be configured on stand-alone or stacked switches. In a stack of switches, the LAG can consist of ports on a single unit or across multiple stack members. When a LAG members span different units across a stack, and a unit fails, the remaining LAG members on the functional units continue to handle traffic for the LAG. Why Are Link Aggregation Groups Necessary? The primary purpose of LAGs is to increase the overall bandwidth between two switches. This is accomplished by effectively aggregating multiple ports together that act as a single, logical connection between the two switches. LAGs also provide redundancy. If a link fails, traffic is automatically redistributed across the remaining links. What Is the Difference Between Static and Dynamic Link Aggregation? Link aggregation can be configured as either dynamic or static. Dynamic configuration is supported using the IEEE 802.3ad standard, which is known as Link Aggregation Control Protocol (LACP). Static configuration is used when connecting a Dell Networking N2000, N3000, and N4000 series switches to an external Gigabit Ethernet switch that does not support LACP. One advantage of LACP is that the protocol enables the switch to confirm that the external switch is also configured for link aggregation. When using static configuration, a cabling or configuration mistake involving the N2000/N3000/N4000 switch or the external switch could go undetected and thus cause undesirable network behavior. Both static and dynamic LAGs (via LACP) can detect physical link failures within the LAG and continue forwarding traffic through the other connected links within that same LAG. LACP can also detect switch or port failures that do not result in loss of link. 914 Configuring Link Aggregation This provides a more resilient LAG. Best practices suggest using dynamic link aggregation instead of static link aggregation.When a port is added to a LAG as a static member, it neither transmits nor receives LACP PDUs. What is LAG Hashing? Dell Networking series switches support configuration of hashing algorithms for each LAG interface. The hashing algorithm is used to distribute traffic load among the physical ports of the LAG while preserving the per-flow packet order. Enhanced hashing mode is the recommended and default hashing mode for Dell Networking switches. The hashing algorithm uses various packet attributes to determine the outgoing physical port. The switch supports the following set of packet attributes to be used for hash computation: • Source MAC, VLAN, EtherType, and incoming port. • Destination MAC, VLAN, EtherType, and incoming port. • Source IP and Source TCP/UDP port numbers. • Destination IP and Destination TCP/UDP port numbers. • Source/Destination MAC, VLAN, EtherType, and incoming port. • Source/Destination IP and Source/Destination TCP/UDP port numbers. • Enhanced hashing mode Enhanced hashing mode has following advantages: • MODULO-N operation based on the number of ports in the LAG. • Packet attributes selection based on the packet type. For L2 packets, Source and Destination MAC address plus physical source port are used for hash computation. For IP packets, Source IP, Destination IP address, TCP/UDP ports, and physical source port are used. • Non-Unicast traffic and Unicast traffic is hashed using a common hash algorithm. • Excellent load balancing performance. Configuring Link Aggregation 915 How Do LAGs Interact with Other Features? From a system perspective, a LAG is treated just as a physical port, with the same configuration parameters for administrative enable/disable, spanning tree port priority, path cost as may be for any other physical port. VLAN When members are added to a LAG, they are removed from all existing VLAN membership. When members are removed from a LAG they are added back to the VLANs that they were previously members of as per the configuration file. Note that a port’s VLAN membership can still be configured when it's a member of a LAG. However this configuration is only actually applied when the port leaves the LAG. The LAG interface can be a member of a VLAN complying with IEEE 802.1Q. STP Spanning tree does not maintain state for members of a LAG, but does maintain state for the LAG interface. As far as STP is concerned, members of a LAG do not have individual link state. (Internally, the STP state of the LAG interface is replicated for the member links.) When members are deleted from a LAG they become normal links, and spanning tree maintains their individual link state information. Statistics Statistics are collected for LAGs in the same manner as they are collected for the physical ports, in addition to the statistics collected for individual members as per the 802.3ad MIB statistics. LAG Configuration Guidelines Ports to be aggregated must be configured so that they are compatible with the link aggregation feature and with the partner switch to which they connect. Ports to be added to a LAG must meet the following requirements: 916 • Interface must be a physical Ethernet link. • Each member of the LAG must be running at the same speed and must be in full duplex mode. Configuring Link Aggregation • The port cannot be a mirrored port The following are the interface restrictions • The configured speed of a LAG member cannot be changed. • An interface can be a member of only one LAG. Default Link Aggregation Values The LAGs on the switch are created by default, but no ports are members. Table 28-1 summarizes the default values for the MAC address table. Table 28-1. MAC Address Table Defaults Parameter Default Value LACP system priority 1 LACP port priority 1 LACP timeout Long LAG hash algorithm type Enhanced (7) Configuring Link Aggregation 917 Configuring Link Aggregation (Web) This section provides information about the OpenManage Switch Administrator pages for configuring and monitoring LAGs on a Dell Networking N2000, N3000, and N4000 series switches. For details about the fields on a page, click at the top of the page. LAG Configuration Use the LAG Configuration page to set the name and administrative status (up/down) of a LAG. To display the LAG Configuration page, click Switching → Ports → LAG Configuration in the navigation panel. Figure 28-2. LAG Configuration 918 Configuring Link Aggregation To view or edit settings for multiple LAGs, click Show All. LACP Parameters Dynamic link aggregation is initiated and maintained by the periodic exchanges of LACP PDUs. Use the LACP Parameters page to configure LACP LAGs. To display the LACP Parameters page, click Switching → Link Aggregation → LACP Parameters in the navigation panel. Configuring Link Aggregation 919 Figure 28-3. LACP Parameters Configuring LACP Parameters for Multiple Ports To configure LACP settings: 1 Open the LACP Parameters page. 2 Click Show All. The LACP Parameters Table page displays. 920 Configuring Link Aggregation Figure 28-4. LACP Parameters Table 3 Select the Edit check box associated with each port to configure. 4 Specify the LACP port priority and LACP timeout for each port. 5 Click Apply. LAG Membership Your switch supports 48 LAGs per system, and eight ports per LAG. Use the LAG Membership page to assign ports to static and dynamic LAGs. To display the LAG Membership page, click Switching → Link Aggregation → LAG Membership in the navigation panel. Configuring Link Aggregation 921 Figure 28-5. LAG Membership Adding a Port to a Static LAG To add a static LAG member: 1 Open the LAG Membership page. 2 Click in the LAG row to toggle the port to the desired LAG. The LAG number displays for that port. The LAG number increases each time you click until the number reaches the maximum LAG number and then returns to blank (no LAG assigned). 3 Click Apply. The port is assigned to the selected LAG, and the device is updated. Adding a LAG Port to a Dynamic LAG by Using LACP To add a dynamic LAG member: 1 Open the LAG Membership page. 2 Click in the LACP row to toggle the desired LAG port to L. NOTE: The port must be assigned to a LAG before it can be aggregated to an LACP. 3 Click Apply. The LAG port is added as a dynamic LAG member to the selected LAG. 922 Configuring Link Aggregation LAG Hash Configuration Use the LAG hash algorithm to set the traffic distribution mode on the LAG. You can set the hash type for each LAG. To display the LAG Hash Configuration page, click Switching → Link Aggregation → LAG Hash Configuration in the navigation panel. Figure 28-6. LAG Hash Configuration LAG Hash Summary The LAG Hash Summary page lists the channels on the system and their assigned hash algorithm type. To display the LAG Hash Summary page, click Switching → Link Aggregation → LAG Hash Summary in the navigation panel. Configuring Link Aggregation 923 Figure 28-7. LAG Hash Summary 924 Configuring Link Aggregation Configuring Link Aggregation (CLI) This section provides information about the commands you use to configure link aggregation settings on the switch. For more information about the commands, see the Dell Networking N2000, N3000, and N4000 Series Switches CLI Reference Guide at support.dell.com/manuals. Configuring LAG Characteristics Beginning in Privileged EXEC mode, use the following commands to configure a few of the available LAG characteristics. Many of the commands described in "Configuring Port Characteristics (CLI)" on page 496 are also applicable to LAGs. Command Purpose configure Enter global configuration mode. interface interface Enter interface configuration mode for the specified LAG. The interface variable includes the interface type, which is port-channel, and the LAG number, for example portchannel 3. You can also specify a range of LAGs with the interface range port-channel command, for example, interface range port-channel 3-6 configures LAGs 3, 4, 5, and 6. description description Configure a description for the LAG or range of LAGs minimum port-channel min-links Set the minimum number of links that must be up in order for the port-channel interface to be declared up. exit Exit to Global Config mode. CTRL + Z Exit to Privileged EXEC mode. show interfaces View the configured description for the specified LAG. description port-channel port-channel number show interfaces portchannel [port-channel number] View LAG information for the specified LAG or for all LAGs. Configuring Link Aggregation 925 Configuring Link Aggregation Groups Beginning in Privileged EXEC mode, use the following commands to add ports as LAG members and to configure the LAG hashing mode. Command Purpose configure Enter global configuration mode. interface interface Enter interface configuration mode for the specified port. The interface variable includes the interface type and number, for example tengigabitethernet 1/0/3. You can also specify a range of ports with the interface range command, for example, interface range tengigabitethernet 1/0/8-12 configures interfaces 8, 9, 10, 11, and 12. channel-group portchannel-number mode {on | auto} Add the port(s) to the LAG specified with the portchannel-number value. Use the auto keyword to add the port(s) as dynamic members, or use on to specify that the LAG membership is static. • port-channel-number — Number of a valid port-channel for the current port to join. • on — Forces the port to join a channel without LACP (static LAG). • active — Forces the port to join a channel with LACP (dynamic LAG). exit Exit to Global Config mode. interface port-channel Enter interface configuration mode for the specified LAG. number 926 You can also specify a range of LAGs to configure with the interface range port-channel command, for example, interface range port-channel 1-3,10 configures LAGs 1, 2, 3, and 10. Configuring Link Aggregation Command Purpose hashing-mode mode Set the hashing algorithm on the LAG. The mode value is a number from 1 to 7. The numbers correspond to the following algorithms: • 1 — Source MAC, VLAN, EtherType, source module, and port ID • 2 — Destination MAC, VLAN, EtherType, source module, and port ID • 3 — Source IP and source TCP/UDP port • 4 — Destination IP and destination TCP/UDP port • 5 — Source/destination MAC, VLAN, EtherType, and source MODID/port • 6 — Source/destination IP and source/destination TCP/UDP port • 7 — Enhanced hashing mode CTRL + Z Exit to Privileged EXEC mode. show interfaces portchannel [port-channel number] View LAG information for the specified LAG or for all LAGs. show statistics portchannel port-channel- View interface statistics for the specified LAG. number Configuring LACP Parameters Beginning in Privileged EXEC mode, use the following commands to configure system and per-port LACP parameters. Command Purpose configure Enter global configuration mode. lacp system-priority Set the Link Aggregation Control Protocol priority for the switch. the priority value range is 1–65535. value Configuring Link Aggregation 927 Command Purpose interface port-channel Enter interface configuration mode for the specified LAG. number You can also specify a range of LAGs to configure with the interface range port-channel command, for example, interface range port-channel 1-3,10 configures LAGs 1, 2, 3, and 10. lacp port-priority value Set the Link Aggregation Control Protocol priority for the port or range of ports. The priority value range is 1–65535. lacp timeout {long | short} Specify whether to wait a long or short time between LACP PDU transmissions. exit Exit to Privileged EXEC mode. show lacp interface View LACP parameters for an Ethernet interface or a LAG. The interface parameter includes the interface type (gigabitethernet, tengigabitethernet, or port-channel) and number. 928 Configuring Link Aggregation Link Aggregation Configuration Examples This section contains the following examples: • Configuring Dynamic LAGs • Configuring Static LAGs NOTE: The examples in this section show the configuration of only one switch. Because LAGs involve physical links between two switches, the LAG settings and member ports must be configured on both switches. Configuring Dynamic LAGs The commands in this example show how to configure a static LAG on a switch. The LAG number is 1, and the member ports are 1, 2, 3, 6, and 7. To configure the switch: 1 Enter interface configuration mode for the ports that are to be configured as LAG members. console(config)#interface range te1/0/1-3,te1/0/6-7 2 Add the ports to LAG 2 with LACP. console(config-if)#channel-group 1 mode active Configuring Link Aggregation 929 3 View information about LAG 1. console#show interfaces po1 Channel ------Po1 Ports Ch-Type Hash Type Min-links Local Prf ------------- ------- --------- --------- --------Active: Dynamic 7 1 Disabled Te1/0/1 Inactive: Te1/0/2, Te1/0/3, Te1/0/6, Te1/0/7 Hash Algorithm Type 1 - Source MAC, VLAN, EtherType, source module and port Id 2 - Destination MAC, VLAN, EtherType, source module and port Id 3 - Source IP and source TCP/UDP port 4 - Destination IP and destination TCP/UDP port 5 - Source/Destination MAC, VLAN, EtherType, source MODID/port 6 - Source/Destination IP and source/destination TCP/UDP port 7 - Enhanced hashing mode Configuring Static LAGs The commands in this example show how to configure a static LAG on a switch. The LAG number is 2, and the member ports are 10, 11, 14, and 17. To configure the switch: 1 Enter interface configuration mode for the ports that are to be configured as LAG members. console(config)#interface range te1/0/10-12, te1/0/14,te1/0/17 2 Add the ports to LAG 2 without LACP. console(config-if)#channel-group 2 mode on 930 Configuring Link Aggregation 3 View information about LAG 2. console#show interfaces po2 Channel ------Po1 Ports Ch-Type Hash Type Min-links Local Prf ------------- ------- --------- --------- --------Active: Static 7 1 Disabled Te1/0/1 Inactive: Te1/0/2, Te1/0/3, Te1/0/6, Te1/0/7 Hash Algorithm Type 1 - Source MAC, VLAN, EtherType, source module and port Id 2 - Destination MAC, VLAN, EtherType, source module and port Id 3 - Source IP and source TCP/UDP port 4 - Destination IP and destination TCP/UDP port 5 - Source/Destination MAC, VLAN, EtherType, source MODID/port 6 - Source/Destination IP and source/destination TCP/UDP port 7 - Enhanced hashing mode Configuring Link Aggregation 931 Multi-Switch LAG (MLAG) Overview In a typical L2 network, the Spanning Tree Protocol (STP) is deployed to avoid packet storms due to loops in the network. To perform this function, STP sets ports into either a forwarding state or a blocking state. Ports in the blocking state do not carry traffic. In the case of a topology change, STP reconverges to a new loop-free network and updates the port states. STP is relatively successful mitigating packet storms in the network, but redundant links in the network are blocked from carrying traffic by the spanning tree protocol. In some network deployments, redundant links between two switches are bundled together in a Link Aggregation Group (LAG) and appear as a single link in the spanning tree topology. The advantage is that all LAG member links can be in the forwarding state and a link failure can be recovered in milliseconds. This allows the bandwidth on the redundant links to be utilized. However, LAGs are limited to connecting multiple links between two partner switches, which leaves the switch as a single point of failure in the topology. Dell Networking MLAG extends the LAG bandwidth advantage across multiple Dell Networking switches connected to a LAG partner device. The LAG partner device is oblivious to the fact that it is connected over a LAG to two peer Dell Networking switches - instead, the two switches appear as a single switch to the partner. All links can carry data traffic across a physically diverse topology and in the case of a link or switch failure, traffic can continue to flow with minimal disruption. 932 Configuring Link Aggregation Deployment Scenarios MLAG is intended to support higher bandwidth utilization in scenarios where a redundant L2 network is desired. In such scenarios the effects of STP on link utilization are profound. Large percentages of links do not carry data because they are blocked and only a single path through the network carries traffic. Figure 28-8. STP Blocking SW4 × SW1 SW2 Traffic does not flow through SW2 due to spanning tree blocking the SW2/SW3 link. SW3 MLAG reduces some of the bandwidth shortcomings of STP in an L2 network. It provides a reduced convergence period when a port-channel link goes down and provides more bandwidth because all links can forward traffic. In the figure below, if SW1 and SW2 form an MLAG with SW3 and SW4, none of the links are blocked, which means traffic can flow over both links from SW4 through to SW1 and SW2 over both links from SW1 and SW2 to SW3. Configuring Link Aggregation 933 Figure 28-9. MLAG in an L2 Network SW4 MLAG Peer Link SW2 SW1 SW3 934 Configuring Link Aggregation Traffic flows on all available links. Definitions Refer to Figure 28-10 for the definitions that follow. Figure 28-10. MLAG Components L3 Network Virtual Link Peer-Link S4 P4 P2 P3 SW1 S2 S3 P1 SW2 S1 MLAG LAG A MLAG switches: MLAG aware switches running Dell Networking OS switch firmware. No more than two MLAG aware switches can pair to form one end of the LAG. Stacked switches do not support MLAGs. In the above figure, SW1 and SW2 are MLAG peer switches. These two switches form a single logical end point for the MLAG from the perspective of switch A. MLAG interfaces: MLAG functionality is a property of port-channels. Portchannels configured as MLAGs are called MLAG interfaces. Administrators can configure multiple instances of MLAG interfaces on the peer MLAG switches. Port-channel limitations and capabilities like min-links and maximum number of ports supported per LAG also apply to MLAG interfaces. Configuring Link Aggregation 935 MLAG member ports: Ports on the peer MLAG switches that are part of the MLAG interface (P1 on SW1 and S1 on SW2). Non-redundant ports: Ports on either of the peer switches that are not part of the MLAG (ports P4 and S4). MLAG interfaces and non-redundant ports cannot be members of the same VLAN, i.e. a VLAN may contain MLAG interfaces or a VLAN may contain non-redundant ports, but not both. MLAG peer-link: A link between the two MLAG peer switches (ports P2,P3,S2,S3). Only one peer-link can be configured per device. The peer-link is crucial for the operation of the MLAG component. A port-channel must be configured as the peer-link. All VLANs configured on MLAG interfaces must be configured on the peer-link as well. MLAG Dual Control Plane Detection link: A virtual link that is used to advertise the Dual Control Plane Detection Protocol (DCPDP) packets between the two MLAG switches (ports P4, S4). DCPDP is optional but should be used with caution. The protocol is used as a secondary means of detecting the presence of the peer switch in the network. The DCPDP protocol must not be configured on MLAG interfaces. Configuration Consistency The administrator must ensure that the neighboring devices connected to MLAG switches perceive the two switches as a single spanning tree and Link Aggregation Control Protocol (LACP) entity. To achieve this end, the following configuration settings must be identical for MLAG links on the MLAG peer switches: 1 Link aggregation 936 – Hashing mode – Minimum links – Static/dynamic LAG – LACP parameters • Actor parameters • Admin key • Collector max-delay • Partner parameters Configuring Link Aggregation 2 STP The default STP mode for Dell Networking switches is RSTP. VLANs cannot be configured to contain both MLAG ports and non-MLAG (nonredundant) ports. Only RSTP or MSTP are supported with MLAG. STPPV and RSTP-PV are not supported with MLAG. The following STP configuration parameters must be the identical on both MLAG peers. – Spanning-tree version (RSTP or MSTP) – Bpdufilter – Bpduflood – Auto-edge – TCN-guard – Cost – Edgeport – STP Version – STP MST VLAN configuration – STP MST instance configuration (MST instance ID/port priority/port cost/mode) – Root guard – Loop guard 3 Port-channel interface The following port-channel attributes must be identical for MLAG portchannels: – Port-channel mode – Link speed – Duplex mode – MTU – Bandwidth – VLAN configuration Configuring Link Aggregation 937 The administrator should also ensure that the following are identical before enabling MLAG: – FDB entry aging timers – Static MAC entries. – ACL configuration 4 Interface Configuration – PFC configuration – CoS queue assignments 5 VLAN configuration – MLAG VLANs must span the MLAG topology and be configured on both MLAG peers. This means that every MLAG VLAN must connect to two partner LAGs. – VLAN termination of an MLAG VLAN on an MLAG peer is not supported. 6 Switch firmware versions Except during firmware upgrade, the peer switch firmware versions must be identical, as subtle differences between versions may cause instability. The administrator must ensure that the above configuration items are configured identically on the MLAG interfaces on both of the MLAG peers before enabling the MLAG feature. If the configuration settings are not in sync, the MLAG behavior is undefined. Once the above configuration is in place and consistent, the two switches will form an MLAG that operates in the desired manner. The MLAG may form even if the configuration is not consistent, however, it may not operate consistently in all situations. 938 Configuring Link Aggregation Operation in the Network Below is a sample MLAG topology and discussion: Figure 28-11. Example MLAG Topology C C1 C2 VLAN 10 MLAG3 Peer-Link P5 P P1 P3,P4 S5 S3,S4 P2 S1 MLAG 1 S S2 MLAG 2 A B In Figure 28-11: 1 VLAN 10 spans the MLAG network. 2 P and S are MLAG-aware peer devices. P stands for primary and S stands for secondary. The roles are elected after the DUTs exchange keep-alive messages. The two devices are connected with a peer-link {P3/P4–S3/S4}. Ports P1, S1 are members of MLAG1 and ports P2, S2 are members of MLAG2. 3 A port-channel must be configured as the peer-link. In Figure 28-11, P3, P4 and S3, S4 are the port-channel ports that form the peer-link. 4 MLAG devices select the roles based on keep-alive messages that run over the peer-link. 5 A, B, and C are MLAG-unaware devices. 6 A, B, and C are partner devices that form an MLAG with P and S. On A, B, and C, the aggregation is a regular LAG. 7 MLAG links are shown in blue. Configuring Link Aggregation 939 Supported topologies and the way traffic is handled in these topologies is explained in the following sections. The MLAG component uses the keep-alive protocol to select a primary and a secondary device. The primary switch owns the MLAG member ports on the secondary device. It handles the control plane functionality of supported protocols for the MLAG member ports on the secondary. Peer-Link The peer-link is a crucial for MLAG operation. The peer-link must be configured on a port-channel interface. Only one peer-link aggregation group is allowed per peer switch and this peer-link is shared by all instances of MLAG running on the two peer switches. The peer-link must NOT have spanning tree enabled. The peer-link is used for the following purposes: • To transport keep-alive messages to the peer. • To sync FDB entries learned on MLAG interfaces between the two MLAG peer switches. • To forward STP BPDUs and LACPDUs received on secondary MLAG member ports to the primary MLAG switch. • To send interface events related to MLAG interface and member ports that occur on the secondary switch to the primary switch. • To transfer MLAG control information between the primary and secondary MLAG switches. • Support a redundant forwarding plane in the case that all member ports of an MLAG interface are down on an MLAG peer. In this case, traffic received on the peer switch destined to the MLAG peer with the downed ports is sent over the peer-link to the peer MLAG switch for forwarding to the partner switch. The peer-link is not utilized for partner traffic unless all LAG links connected to an MLAG partner on a single MLAG peer are disrupted. It is strongly recommended that the MLAG peer LAG consist of multiple physical links with sufficient bandwidth to carry all traffic expected to be carried by either of the MLAG peers. 940 Configuring Link Aggregation The MLAG component internally configures filters so that traffic ingressing a peer-link is blocked from egress on the peer MLAG switch. The filters are modified when there is a failure of all the MLAG member interfaces on an MLAG switch and traffic must egress through selected ports on the MLAG peer. These filters block incoming traffic on all VLANs configured on the peer link, not just those configured as part of an MLAG. Therefore, there is no connectivity between non-redundant ports across the peer-link. Control Plane Election in MLAG Switches The MLAG component uses the keep-alive protocol to select a primary and a secondary switch. The keep-alive protocol is mandatory. The selection of the primary switch is non-preemptive and is not configurable. Once elected, the primary switch owns the MLAG member ports on the secondary device. It handles the control plane functionality of supported protocols for the MLAG member ports on the secondary switch. Protocol status is not sent from the primary to the secondary switch. Always use the management interface on the primary switch to examine MLAG status. Peer-Link Keep-alive Protocol MLAG peers exchange keep-alive packets over the peer-link. The keep-alive protocol is L2-based. Keep-alive messages are used for electing roles and to inform the MLAG peer that the MLAG switch is alive and functioning properly. The keep-alive protocol sends messages with an Ether-type of 0x88E8 addressed to destination MAC 01:00:B5:00:00:00. Dual Control Plane Detection Protocol The MLAG component may optionally run the Dual Control Plane Detection Protocol (DCPDP) to detect the presence of the peer switch independently of the keep-alive protocol running on the peer link. The Dual Control Plane Detection Protocol is a UDP-based L3 protocol. DCPDP may be configured on a routed VLAN that does not contain any MLAG port-channel interfaces. When enabled, the DCPDP sends an L3 control plane detection message to the peer once every second. The message is unidirectional and contains the senders MAC address in the payload. The state of the primary and secondary MLAG switches is maintained on both MLAG peers. DCPDP runs over an IP interface when enabled. Configuring Link Aggregation 941 DCPDP and Peer Link Failures DCPDP is intended to provide a secondary layer of protection against peer link failures. If the peer-link goes down but the DCPDP protocol is enabled and remains up, the MLAG links on the MLAG secondary peer are disabled. If the peer-link is restored, a new primary switch is elected, the primary switch assumes control over the secondary peer, and the MLAG links are brought up. In the case where there are no keep-alive messages detected from the peer and DCPDP is disabled, but both peer units remain up, two primary switches result, each with a unique MAC address, and each operating over its part of the former MLAG. In this situation, the selection of dynamic or static LAGs determines the MLAG behavior. On a peer-link failure with DCPDP disabled and the MLAG configured with dynamic LAGs to the partners, traffic forwarding continues through the primary MLAG switch. LACP running on the partner device detects that the port-channel connected to the secondary MLAG switch is sending LACPDUs with a different system ID and brings down the links connected to secondary MLAG peer. This behavior reduces or eliminates spanning tree reconvergence due to the MLAG switches sending BPDUs with different bridge IDs to the partner switch. On a peer-link failure with DCPDP disabled and the MLAG configured with static LAGs to the partners, traffic forwarding continues through both the primary and secondary MLAG switches. Spanning tree sends BPDUs with different bridge IDs to the partner switch, resulting in serial spanning tree reconvergence. For this reason, dynamic MLAGs are strongly recommended. L2 Configuration Steps This section describes how to configure two MLAG peers in a basic L2 switching configuration with the default spanning-tree configuration. 1 Enable MLAG globally and create the MLAG VLANs: feature vpc vlan 10-17 exit 2 Configure the keep-alive protocol: a 942 Configure the device priority using the role command, if desired. This should be configured differently for each of the MLAG peers. Configuring Link Aggregation b Configure the timeout interval, if desired. vpc domain 1 role 10 exit Modifications to priority and timeout interval are effective only before the keep-alive protocol is enabled. Once enabled, MLAG switches contest in an election to select the primary and secondary switch. The election is non-preemptive. 3 Configure the peer-link. On each MLAG peer: • Configure a port-channel as the peer-link for the MLAG devices. It is recommended that the administrator use dynamic LAGs as portchannels. • It is strongly recommended that the MLAG peer LAG consist of multiple physical links with sufficient bandwidth to carry all MLAG traffic expected to be carried by either MLAG peer. • Disable spanning tree on the peer-link. • Enable trunking on the peer-link. Remove any non-MLAG VLANs from the peer-link trunk port. VLANs cannot be configured to contain both MLAG ports and non-MLAG (non-redundant) ports. • Ensure that the peer-link has a native VLAN configured. • Optionally, configure UDLD on the peer-link to detect and shut down unidirectional links. • Associate the port-channel with physical links. interface port-channel 1 description "MLAG-Peer-Link" spanning-tree disable switchport mode trunk vpc peer-link exit interface range te1/0/1-2 channel-group 1 mode active description "MLAG-Peer-Link" udld enable udld port aggressive exit Configuring Link Aggregation 943 When the peer-link is configured, the MLAG component disables learning on the port-channel configured as the peer-link. 4 Configure DCPDP (optional): a Configure a VLAN routing interface and assign a local IP address (different from the peer address). b Configure the peer-switch IP address (the destination IP address) c If needed, configure the UDP port number to send and receive the protocol messages. d Configure the source IP address e Enable the protocol. The protocol starts running if MLAG is globally enabled. vlan 100 interface vlan 100 ip address 192.168.0.2 255.255.255.0 exit vpc domain 1 peer-keepalive destination 192.168.0.1 source 192.168.0.2 peer detection enable exit 5 Configure the MLAG partner interfaces: Configure a port-channel as an MLAG interface and assign to a VPC. Each MLAG must have a unique VPC ID and the VPC configuration must be identical on both switches. The port-channels on the MLAG peer must be assigned to the same VPC ID. However, the member ports for the portchannel may be different. The administrator must ensure that the portchannel configuration on both the switches is in sync before enabling MLAG. After the MLAG interfaces are enabled, the MLAG interfaces are operationally disabled for a brief period while the MLAG component exchanges information regarding the port members that constitute the port-channel on each device. Once this information is populated on both devices, the MLAG interfaces are operationally enabled and traffic forwarding on MLAG interfaces is allowed. The secondary switch forwards all BPDUs/LACPDUs received on the port members of the MLAG interface to the primary switch over the peer-link. Events related to MLAG interface and their port members are forwarded 944 Configuring Link Aggregation to the primary switch for handling. FDB entries learned on MLAG interfaces are synced between the two devices. interface range gi1/0/1-4 channel-group 2 mode active exit interface range gi1/0/5-8 channel-group 3 mode active exit interface port-channel 2 switchport mode trunk vpc 1 exit interface port-channel 3 switchport mode trunk vpc 2 exit Switch Firmware Upgrade Procedure MLAG supports minimally intrusive firmware upgrade of the MLAG peer switches. In most cases, protocols with retransmission capability, e.g., TCP, will experience a limited interruption of service. Network operators must ensure that the aggregate bandwidth in use on the MLAG can be supported on a single MLAG peer. Use the show vpc brief command to determine which switch is the primary switch. This procedure upgrades the standby switch first, followed by the primary switch. Following this order reduces the reconvergence time to the minimum. Upgrade Steps Disable DCPDP if enabled: 1 On the secondary switch, disable DCPDP if enabled and save the configuration. 2 On the primary switch, disable DCPDP if enabled and save the configuration. Upgrade the MLAG standby switch: 1 On the MLAG standby switch, shut down the MLAG-enabled physical links (not the port-channel). Configuring Link Aggregation 945 2 On the MLAG standby switch, shut down the MLAG peer-link. 3 Copy the new firmware to the standby switch, activate it, and reboot the switch. 4 Re-enable the peer-link, if disabled, and ensure that it is up. Re-enable the MLAG-associated physical ports. 5 Wait until traffic is re-established on the standby switch. Repeat the upgrade procedure on the MLAG primary peer: 1 On MLAG primary switch, shut down the MLAG enabled physical links. 2 On MLAG primary switch, shut down the MLAG peer-link. 3 Copy the new firmware to the primary switch, activate it, and reboot the switch. 4 Re-enable the peer link, if disabled, and ensure that it is up. Re-enable the MLAG-associated physical ports. 5 Verify that traffic is re-established on the primary switch after the reconvergence. At this point, the switch firmware is upgraded and the MLAG is fully functional. Static Routing on MLAG Interfaces MLAG interfaces can be enabled as L3 VLANs; that is, they can be assigned IP addresses. Static inter-VLAN routing is NOT supported on MLAG VLANs on the MLAG peers, and every MLAG VLAN must terminate on two MLAG partners. There is no support for routing protocols such as OSPF, RIP, etc. on MLAG interfaces. VRRP can be configured on these routing interfaces to provide Virtual IP/Virtual MAC redundancy. Routing is supported only on the edge of the MLAG towards the partner network, in support of implementing a subnet per VLAN towards which the partner network can route. The interior MLAG VLANs, and especially the MLAG peer links, must be configured for switching and must span the MLAG topology. MLAGs and Routing MLAG is supported as a replacement for spanning tree in L2 switched network topologies. When connecting to routed networks, the links/VLANs on the router must be part of the MLAG domain, and the links/VLANs leading to the rest of the L2 network or to L3 hosts must be part of the 946 Configuring Link Aggregation MLAG domain for the MLAG feature to automatically utilize the peer-link to forward packets around failures. MLAG VLANs may have IP addresses assigned, but MLAG VLANs cannot be used to route across MLAG or nonredundant VLANs, as the MLAG feature does not correlate failures in one VLAN with another VLAN to unblock packets crossing the MLAG peer-link. Recommended L3 Connectivity The topology shown in Figure 28-12 uses the MLAG switches as L2 switches. All VLANs traverse the MLAG topology from the top switches/routers to the bottom switches/routers. The LAGs for each VLAN host are in a separate VPC. The router sees the port-channel as a single logical interface with multiple VLANs. This topology is highly recommended as it utilizes MLAG in the scenario for which it was intended (redundant full-bandwidth replacement for spanning tree) and allows the MLAG peers to detect failures and unblock the appropriate VLANs on the peer link so that traffic flow can continue unimpeded. Figure 28-12. Recommended L3 Connectivity L3 Router Failed Link MLAG VLAN 10, 20, 30 Peer-Link MLAG Router Peer MLAG Router Peer MLAGs VLAN 10 Host VLAN 20 Host VLAN 30 Host Configuring Link Aggregation 947 Alternative Recommended L3 Connectivity The loop-free topology shown in Figure 28-13 uses the MLAG switches as L2 switches in an EOR role. The single VLAN traverses the MLAG topology from the top router to the bottom storage and servers. Multiple VLANs in different VPCs may be used to isolate clusters of storage/servers from each other. This topology is highly recommended, as it utilizes MLAG in the scenario for which it was intended (redundant full-bandwidth replacement for spanning tree in a fully L2 topology) and allows the MLAG peers to detect failures and unblock the appropriate VLANs on the peer link so that traffic flow can continue unimpeded. The lower pair of switches connects clusters of storage and servers in a TOR role in support of devices that do not support link aggregation. Switching between the storage and the servers within the rack proceeds in the normal manner and remains isolated on the lower switch pair that is not part of the MLAG domain. Traffic entering or exiting the rack proceeds over the EOR MLAG. Figure 28-13. Alternative Recommended L3 Connectivity Router MLAG MLAG Peer Switch MLAG Peer Switch MLAG Switch (not part of MLAG domain) Storage 948 MLAG Switch (not part of MLAG domain) Server Configuring Link Aggregation Server Storage L3 VLAN Termination on MLAG Not Supported In the “two-armed” fully routed scenario shown in Figure 28-14, both the routed network and the switched network are in the MLAG. Switched traffic to and from the upstream network is automatically unblocked over the peerlink when an MLAG link fails. But, because the failed link is part of an L3 port-channel (with a unique VLAN), the peer-link does not automatically unblock the downstream routed VLANs (which are not correlated with the upstream MLAG VLANs) across the peer link. Specifically, MLAG does not correlate the failure in VLAN 30 with VLAN 20. This leads to a black hole. Adding a backup routed link solves the black hole issue, but it also makes the MLAG solution unnecessary. L3-routed VLAN termination on the MLAG peers is not supported—VLANs must extend across the MLAG peers to two MLAG partners. Figure 28-14. L3 VLAN Termination on MLAG, Example 1 Router Failed Link MLAG VLAN 30 Peer-Link MLAG Router Peer MLAG Router Peer MLAG VLAN 20 Switched Network Only Configuring Link Aggregation 949 In the scenario shown in Figure 28-15(similar to the previous scenario), the downstream router is not configured with port-channel and uses ECMP or some other load sharing scheme to send packets to routed MLAG peers. MLAG cannot react appropriately to a link failure on the upstream router because the VLANs are routed across the MLAG peers. MLAG cannot logically connect the failure on VLAN 30 with orphan VLAN 20. Consequently, MLAG does not unblock VLAN 20 from traversing the peer link. The downstream router continues to send packets on VLAN 20 to the MLAG peer with the failed link. But because routed VLAN 20 is not part of the MLAG, packets remain blocked when transiting the MLAG peer link. L3 routed VLANs termination on the MLAG peers is not supported—VLANs must extend across the MLAG peers. Figure 28-15. L3 VLAN Termination on MLAG, Example 2 Router Failed Link MLAG VLAN 30 Peer-Link MLAG Router Peer MLAG Router Peer VLAN 20 Router Degenerate Routing Topology In a “one-armed” topology, the MLAG is partnered with a single router or switch. The router is configured with a LAG toward the MLAG peer switches and has an IP address configured on the router LAG. The peer switches may be configured with VRRP and have IP addresses assigned to both the routed VLANs. If a multi-tier MLAG topology is used below the MLAG peers, these switches must not have L3 port-channels configured as part of the MLAG. An additional backup routed link between the MLAG peers is required to handle 950 Configuring Link Aggregation the case where a link from the router to one of the MLAG peers fails. Static routes must be added to the primary and secondary MLAG peers to route traffic addressed to the connected router across the backup routed link in the case of a failure of an MLAG link to the router. This is not a recommended topology, as the same scenario can be achieved without the use of MLAG by simply configuring the middle switches as routers and using ECMP to load-balance across the links to the redundant router pair. In this type of solution, MLAG adds no value, as the redundancy is provided by L3 routing, not by the MLAG. Figure 28-16. Degenerate Routing Topology Router VLAN 30 IP address 192.168.30.1/24 VLAN 30 MLAG Failed Link Peer-Link VLAN 10 IP address 192.168.10.1/24 16 IP route 192.168.30.1 192.168.20.1 200 8 VLAN 10 IP address 192.168.10.2/24 route 192.168.30.1 192.168.10.1 200 IP rout VLAN 20 VLAN 20 Router or Switch In the one-armed scenario in Figure 28-16, the MLAG cannot associate the failure of the VLAN 30 link with VLAN 20. Traffic from the routed or switched network towards the upstream router is routed over the backup router link when the MLAG link fails solely based on the routing configuration. Traffic from the upstream router on VLAN 30 to the switched/routed network is handled by the MLAG failover scenario and is switched across the peer-link on VLAN 30, but it could just as easily be handled by L3 routing. Configuring Link Aggregation 951 Virtual Router Redundancy Protocol If VRRP is enabled on a VLAN that has an MLAG port as its member, both VRRP routers become VRRP masters operationally in the VLAN. This is to allow load balancing of the northbound L3 traffic on the MLAG. Since the peer-link is a member of the same routing VLANs as all MLAGs, both the primary and secondary MLAG routers see VRRP advertisements sent by the other router. The internal switch packet filters are modified to drop VRRP advertisement packets if they are received on a VLAN that has an MLAG as its member. This ensures that both MLAG devices become VRRP Masters. Consider the scenario in Figure 28-17. Figure 28-17. MLAG with VRRP R1 P A S S2 B When L3 data is received by the MLAG primary switch destined to A, P would trigger an ARP request to learn A's MAC address. In this case, the ARP request originated by P would have its interface MAC address as the source MAC address (MAC-P, for example) and interface IP address as the source IP address. If the ARP reply from A, with destination MAC address as MAC-P, is hashed to S, the packet will be forwarded by S to P over the peer-link so that P can learn A's MAC address. This requires that the virtual IP address of the VRRP “routers” be different from the physical IP of either of the MLAG peers. This is to ensure that packets generated by either of the MLAG peers is 952 Configuring Link Aggregation transmitted with the source MAC address as the physical MAC address and not the virtual MAC address. In the example in Figure 28-17, if the virtual MAC address is used as the source MAC address in the ARP from P to A, then S will consume the packet, as it is operationally a VRRP master too. The packet is forwarded to P if the physical MAC address is used. Note that the VLANs connecting A and B to the MLAG peers are extended to R1. P and S do not actually route packets. Within the MLAG domain, packets are switched only. Caveats and Limitations Traffic to and from non-redundant ports is filtered and never crosses the MLAG peer-link, and such ports/VLANs need to obtain connectivity via an alternative other than the MLAG-connected ports/VLANs. Port-channel numbers within a VPC must be identical. MLAG non-redundant ports do not run spanning tree and should be used and connected with caution. It is recommended that these ports be configured and used as routing interfaces on point-to-point links and only configured with VLANs that are not part of the MLAG domain. MLAG peer switches must be the same model and have the same port count and module occupancy (if modules are used in the MLAG domain). Specifically, a port referred to on the secondary must be present on the master to be accepted for configuration. This is due to the table sizes (ARP, FDB, etc.), where the primary switch may learn more MAC addresses than the secondary switch and then, upon failover, the secondary will not be able to forward traffic to all of the addresses supported by the primary switch. It is a requirement of a port-channel that the link members operate at the same duplex and speed settings. In addition, copper ports have larger latencies than fiber ports. If fiber and copper ports are aggregated together, packets sent over the fiber ports would arrive significantly sooner at the destination than packets sent over the copper ports. This can cause significant issues in the receiving device, as it would be required to buffer a potentially large number of frames. Devices unable to buffer the requisite number of frames will show excessive frame discard. Routing is not supported across multiple MLAGs (i.e., in two-tier topology). This is a fundamental limitation of MLAG, which is intended as a replacement for other, less efficient L2 topologies. Should a multitier L3 topology be desired, other well established and well understood techniques, Configuring Link Aggregation 953 such as ECMP and redundant router pairs, will allow a L3 routed network to utilize bandwidth efficiently. L3 routing is capable of routing packets around failed links and failed routers. Spanning tree (and LACP) PDUs are proxied from the secondary MLAG peer to the MLAG primary switch. This implies that at least two spanning tree roots will exist in the MLAG network. Spanning tree on the secondary switch shows as the root bridge because, in a properly configured network, it will have no ports attached. In an improperly configured network, one in which orphan ports and orphan port VLANs are configured on one or both MLAG switches, three root bridges may appear in the network: the root bridge for the MLAG member ports/VLANs on the primary switch, the port-less root bridge on the secondary switch, and the root bridge for the orphan ports/VLANs that are not part of the MLAG. Careful planning may be required when configuring the network to ensure that orphan ports are isolated on the MLAG peers, and segregating the MLAG VLANs from the non-MLAG VLANs to not cross the peer link can reduce the number of root bridges in the network to two. The peer link requires a native VLAN to be configured. This is a limitation of the peer-link keep alive protocol. On primary switch failover, the secondary switch flushes the FDB MAC addresses and uses its own MAC address in spanning tree BPDUs and in the LACP actor ID. This will cause LACP to rebuild the link aggregation group followed by spanning tree reconvergence. MLAG-supported protocols are active only on the MLAG primary switch. The protocols are proxied from the secondary peer switch to the primary switch. The primary switch receives state information from the secondary peer switch and programs the secondary peer hardware. It does not send protocol state information to the secondary peer. This leads to a number of seemingly inconsistent behaviors if these facts are ignored: 954 • MLAG port-channel state is maintained on the primary peer only. The MLAG secondary peer has accurate state for the member links, but not for an MLAG port-channel. The operator can shut down a MLAG portchannel only from the primary MLAG peer. • Shutting down a MLAG port-channel on the primary peer shuts down the port-channel on both the primary and secondary MLAG peers. Configuring Link Aggregation • Shutting down a MLAG port-channel on the secondary MLAG peer has no effect. The operator can shut down the individual links instead. • The spanning tree status is only shown correctly on the primary MLAG peer. • The secondary switch shows the spanning tree status as root. This is because there are no ports belonging to spanning tree on the secondary switch. MLAG ports on the secondary switch belong to the spanning tree running on the primary switch. • On a failover from the primary MLAG peer to the secondary MLAG peer, the ports are made members of the secondary MLAG peer switch's spanning tree and spanning tree reconvergence occurs. The forwarding database and ARP cache are flushed and relearned. • MLAG (VPC) status only shows correctly on the primary MLAG peer and does not show correctly on the secondary MLAG peer. Status is not forwarded from the primary MLAG peer to the secondary MLAG peer. The Dell Networking MLAG solution is not peer-compatible with other vendor's multichassis LAG solutions. Dell Networking switches configured for MLAG cannot peer with another vendor switch. IGMP snooping is not supported on MLAG-enabled switches. Disable IGMP snooping before enabling MLAG. MLAG interfaces and non-redundant ports cannot be members of the same VLAN; i.e., a VLAN may contain MLAG interfaces or a VLAN may contain non-redundant ports, but not both. The Dell Networking MLAG solution supports MSTP and RSTP spanning tree modes only. Spanning tree may also be disabled on the MLAG peers. STP-PV and RSTP-PV are not supported in the MLAG solution. Only two switches are supported as MLAG peers. These switches may not be stacked with other switches. The MLAG peer switches synchronize the state of spanning tree, the L2 forwarding cache, and other protocols to support reduced convergence times during MLAG link and MLAG switch failures. The synchronized state is only available on the MLAG primary switch. Table 28-1 indicates which switch features synchronize their state across the MLAG peers. Configuring Link Aggregation 955 • An N/A entry indicates that state synchronization is not required (usually for a link local protocol) and the feature can be configured on an MLAG VLAN or MLAG-associated links. In some cases, it may be necessary to configure an N/A feature identically on the MLAG peer switches for it to work properly; e.g., port mirroring for an MLAG link must be configured on both MLAG peer switches to capture the conversation from the MLAG partner switch. • A Yes entry indicates that the feature may be configured on an MLAG VLAN and will synchronize state across the MLAG peers. The configuration for features marked Yes must be identical on both switches. MLAG does not synchronize configuration with the MLAG peer. • A No entry indicates that the switch feature does not synchronize state across the MLAG peers and the feature may not be configured on an MLAG VLAN. Table 28-2. MLAG State Synchronization Per Feature Components MLAG State Synchronization Support DOT1Q Yes Protocol Based VLANs/802.1v No GARP No GVRP No GMRP No DOT1P No Unauthenticated VLAN No Voice VLAN No Guest VLAN No MAC Authentication Bypass No Broadcast Storm Recovery No DOT3AD Yes LAG Hashing Yes Port Mirroring N/A MAC Filter N/A 956 Configuring Link Aggregation Table 28-2. MLAG State Synchronization Per Feature (Continued) Components MLAG State Synchronization Support MFDB No IGMP/MLD Snooping No DOT1Qbb No DOT1S Yes Loop Guard No FDB Yes MACLOCK No DVLAN No DOT1AB No IP Subnet-based VLANs N/A MACVLAN N/A Protected Port No DHCP Snooping No IP Source Guard No Dynamic ARP Inspection No Auto-Negotiation N/A L2-Relay No MRP No MMRP No DOT1AS No 802.1qav No DOT1AG No ACL N/A DiffServ N/A COS N/A ACL Logging N/A Flow-based port mirroring N/A Configuring Link Aggregation 957 Table 28-2. MLAG State Synchronization Per Feature (Continued) Components MLAG State Synchronization Support VOIP No iSCSI No DOT1AD No DOT3AH No DCBX N/A ETS N/A FIP Snooping No MVRP No Management ACL No UDLD N/A Private VLAN No LLPF No Port Aggregator No EAV No MSRP No MVR No Class-Based VLAN No DHCP Filtering No EASY_ACL No Media VLAN No PBVLAN No VLAN-Rate Limit No Flow Control N/A LLDP N/A Jumbo Frames N/A 958 Configuring Link Aggregation Basic Configuration Example This example shows the configuration of the two MLAG peers and a single MLAG partner in the simplest possible configuration. No MLAG peer priorities are configured, nor is UDLD enabled on the peer-link. DCPDP is not enabled. The default spanning tree configuration is used and spanningtree is disabled on the peer link. MLAG Peer A !Current Configuration: !System Description "Dell Networking N3024F, 6.0.0.0, Linux 3.6.5858bcf6e" !System Software Version 6.0.0.0 ! configure vlan 10 exit hostname "MLAG-Peer-A" slot 1/0 2 ! Dell Networking N3024F stack member 1 2 ! N3024F exit ! interface Gi1/0/23 channel-group 2 mode active description "MLAG-Partner-Link" exit ! interface Te1/0/1 channel-group 1 mode active description "MLAG-Peer-Link" exit ! interface port-channel 1 description "MLAG-Peer-Link" spanning-tree disable switchport mode trunk vpc peer-link exit ! interface port-channel 2 switchport mode trunk switchport trunk native vlan 10 vpc 1 Configuring Link Aggregation 959 exit snmp-server engineid local 800002a203001ec9dec52b snmp-server agent boot count 2 feature vpc vpc domain 1 peer-keepalive enable exit exit MLAG Peer B !Current Configuration: !System Description "Dell Networking N3024F, 6.0.0.0, Linux 3.6.5858bcf6e" !System Software Version 6.0.0.0 ! configure vlan 10 exit hostname "MLAG-Peer-B" slot 1/0 2 ! Dell Networking N3024F stack member 1 2 ! N3024F exit ! interface Gi1/0/23 channel-group 2 mode active description "MLAG-Partner-Link" exit ! interface Te1/0/1 channel-group 1 mode active description "MLAG-Peer-Link" exit ! interface port-channel 1 description "MLAG-Peer-Link" spanning-tree disable switchport mode trunk vpc peer-link exit ! interface port-channel 2 switchport mode trunk switchport trunk native vlan 10 960 Configuring Link Aggregation vpc 1 exit snmp-server engineid local 800002a203001ec9dec513 snmp-server agent boot count 3 feature vpc vpc domain 1 peer-keepalive enable exit exit MLAG Partner !Current Configuration: !System Description "Dell Networking N2048, 6.0.0.0, Linux 3.6.5858bcf6e" !System Software Version 6.0.0.0 ! configure hostname "LAG-SW" slot 1/0 5 ! Dell Networking N2048 stack member 1 8 ! N2048 exit interface vlan 1 ip address dhcp exit ! interface Gi1/0/1 channel-group 1 mode active exit ! interface Gi1/0/2 channel-group 1 mode active exit ! interface port-channel 1 switchport mode trunk exit snmp-server engineid local 800002a203001ec9deb777 snmp-server agent boot count 3 exit Configuring Link Aggregation 961 Status Reporting The status outputs of the various VPC commands are self-explanatory. Both the configured and operational status is shown in the outputs. Additional commands are shown below that may be useful in troubleshooting MLAG configuration or operational issues. All of the commands below are run on the MLAG primary switch except as noted otherwise. MLAG-Peer-A(config)#show vpc brief VPC admin status............................... Keep-alive admin status........................ VPC operational status......................... Self role...................................... Peer role...................................... Peer detection admin status.................... Enabled Enabled Enabled Primary Secondary Disabled Peer-Link details ----------------Interface...................................... Peer-link admin status......................... Peer-link STP admin status..................... Configured VLANs............................... Egress tagged VLANs............................ Po1 Enabled Disabled 1,10 10 VPC Details ----------Number of VPCs configured...................... 1 Number of VPCs operational..................... 1 VPC id# 1 ----------Interface...................................... Po2 Configured VLANs............................... 1,10 VPC interface state............................ Active Local Members ----------------Gi1/0/23 Status -----Up Peer Members ---------------Gi1/0/23 Status -----Up 962 Configuring Link Aggregation LAG-SW(config)#show vpc role Self ---Keep-alive admin status........................ Keep-alive operational status.................. Priority....................................... System MAC address............................. Time-out....................................... VPC admin status............................... VPC role....................................... Disabled Disabled 100 001E.C9DE.B777 5 Disabled None Peer ---Priority....................................... 0 VPC role....................................... None System MAC address............................. 0000.0000.0000 LAG-SW(config)#show vpc peer-keepalive Peer IP address................................ Source IP address.............................. UDP port....................................... Peer detection................................. Peer detection operational status.............. Peer is detected............................... 0.0.0.0 0.0.0.0 50000 Disabled Down False MLAG-Peer-A(config)#show interfaces status po1 Port Description Channel ------- -----------------------------Po1 MLAG-Peer-Link Operational State.............................. Up Admin Mode..................................... Enabled Port Channel Flap Count........................ 1 Member Ports --------Te1/0/1 Device/ Timeout ------------actor/long partner/long Port Speed -----10000 Port Active -----True Flap Count -----1 Configuring Link Aggregation 963 MLAG-Peer-A(config)#show interfaces status po2 Port Description Channel ------- -----------------------------Po2 Operational State.............................. Up Admin Mode..................................... Enabled Port Channel Flap Count........................ 0 Member Ports --------Gi1/0/23 Device/ Timeout ------------actor/long partner/long Port Speed -----1000 Port Active -----True Flap Count -----0 MLAG-Peer-A(config)#show interfaces utilization po1 Port Load Rx bits/s Rx packets/s Tx bits/s Tx packets/s Channel Interval --------- -------- --------------- -------------- --------------- ------------Po1 300 792 1 1192 2 MLAG-Peer-A(config)#show vpc role Self ---Keep-alive admin status........................ Keep-alive operational status.................. Priority....................................... System MAC address............................. Timeout........................................ VPC state...................................... VPC role....................................... Enabled Enabled 100 001E.C9DE.C52B 5 Primary Primary Peer ---Priority....................................... 100 964 Configuring Link Aggregation VPC role....................................... Secondary System MAC address............................. 001E.C9dE.C513 MLAG-Peer-B#show vpc statistics peer-link Peer Peer Peer Peer Peer Peer Peer Peer Peer Peer Peer Peer Peer Peer Peer Peer Peer Peer link link link link link link link link link link link link link link link link link link control messages transmitted......... control messages Tx errors........... control messages Tx timeout.......... control messages ACK transmitted..... control messages ACK Tx errors....... control messages received............ data messages transmitted............ data messages Tx errors.............. data messages Tx timeout............. data messages received............... BPDU's transmitted to peer........... BPDU's Tx errors..................... BPDU's received from peer............ BPDU's Rx errors..................... LACPDU's tranmsitted to peer......... LACPDU's Tx errors................... LACPDU's received from peer.......... LACPDU's Rx errors................... 95 0 0 37 0 37 777 0 0 878 2 0 11 0 775 0 867 0 MLAG-Peer-B#show vpc statistics peer-keepalive Total transmitted.............................. Tx successful.................................. Tx errors...................................... Total received................................. Rx successful.................................. Rx Errors...................................... Timeout counter................................ 15545 15545 0 15542 15542 0 0 Configuring Link Aggregation 965 A Complete Example The following example configures eight VLANs (10–17) across two VPCs. VPC 1 is connected to an N2048 over two links (gi1/0/23-24) over portchannel 2 on each MLAG peer. Interfaces Te1/0/1-2 on each MLAG peer connect to each other on port-channel 1 utilizing LACP. UDLD is enabled on the two MLAG peer-links and the timers are configured to the minimum values. DCPDP is enabled on routed VLAN 100 (interface gi1/0/8 on each MLAG peer). VLAN 100 is excluded from any MLAG interface, including the peer-link. VPC 2 is connected to a legacy Cisco 3750 over port-channel 3 on each MLAG peer, and is also running LACP. The Cisco configuration is shown for completeness. Spanning tree instance 0 is configured for VLAN 1. Spanning tree instance 1 is configured for VLANs 10–17. The Cisco 3750 acts as the root bridge for the topology. MLAG Peer A Configuration !Current Configuration: !System Description "Dell Networking N3024F, 6.0.0.0, Linux 3.6.5858bcf6e" !System Software Version 6.0.0.0 ! configure vlan 10-17,100 exit hostname "MLAG-Peer-A" slot 1/0 2 ! Dell Networking N3024F stack member 1 2 ! N3024F exit interface vlan 100 ip address 192.168.0.1 255.255.255.0 exit spanning-tree mode mst spanning-tree mst configuration instance 1 add vlan 10-17 exit udld enable udld message time 7 udld timeout interval 9 ! 966 Configuring Link Aggregation interface Gi1/0/1 channel-group 3 mode active description "Old-Iron-Partner-Link" exit ! interface Gi1/0/8 switchport access vlan 100 exit ! interface Gi1/0/23 channel-group 2 mode active description "MLAG-Partner-Link" exit ! interface Gi1/0/24 channel-group 2 mode active description "MLAG-Partner-Link" exit ! interface Te1/0/1 channel-group 1 mode active description "MLAG-Peer-Link" udld enable udld port aggressive exit ! interface Te1/0/2 channel-group 1 mode active description "MLAG-Peer-Link" udld enable udld port aggressive exit ! interface port-channel 1 description "MLAG-Peer-Link" spanning-tree disable switchport mode trunk switchport trunk allowed vlan 1-99,101-4093 vpc peer-link exit ! interface port-channel 2 switchport mode trunk switchport trunk allowed vlan 1-99,101-4093 vpc 1 exit Configuring Link Aggregation 967 ! interface port-channel 3 description "Old-Iron-Partner-Link" switchport mode trunk switchport trunk allowed vlan 1-99,101-4093 vpc 2 exit snmp-server engineid local 800002a203001ec9dec52b snmp-server agent boot count 2 feature vpc vpc domain 1 peer-keepalive enable peer-keepalive destination 192.168.0.2 source 192.168.0.1 peer detection enable exit exit MLAG Peer B Configuration !Current Configuration: !System Description "Dell Networking N3024F, 6.0.0.0, Linux 3.6.5858bcf6e" !System Software Version 6.0.0.0 ! configure vlan 10-17,100 exit hostname "MLAG-Peer-B" slot 1/0 2 ! Dell Networking N3024F stack member 1 2 ! N3024F exit interface vlan 100 ip address 192.168.0.2 255.255.255.0 exit spanning-tree mode mst spanning-tree mst configuration instance 1 add vlan 10-17 exit udld enable udld message time 7 udld timeout interval 9 ! interface Gi1/0/1 channel-group 3 mode active 968 Configuring Link Aggregation description "Old-Iron-Partner-Link" exit ! interface Gi1/0/8 switchport access vlan 100 exit ! interface Gi1/0/23 channel-group 2 mode active description "MLAG-Partner-Link" exit ! interface Gi1/0/24 channel-group 2 mode active description "MLAG-Partner-Link" exit ! interface Te1/0/1 channel-group 1 mode active description "MLAG-Peer-Link" udld enable udld port aggressive exit ! interface Te1/0/2 channel-group 1 mode active description "MLAG-Peer-Link" udld enable udld port aggressive exit ! interface port-channel 1 description "MLAG-Peer-Link" spanning-tree disable switchport mode trunk switchport trunk allowed vlan 1-99,101-4093 vpc peer-link exit ! interface port-channel 2 switchport mode trunk switchport trunk allowed vlan 1-99,101-4093 vpc 1 exit ! interface port-channel 3 Configuring Link Aggregation 969 description "Old-Iron-Partner-Link" switchport mode trunk switchport trunk allowed vlan 1-99,101-4093 vpc 2 exit snmp-server engineid local 800002a203001ec9dec513 snmp-server agent boot count 3 feature vpc vpc domain 1 peer-keepalive enable peer-keepalive destination 192.168.0.1 source 192.168.0.2 peer detection enable exit exit MLAG Partner Configuration !Current Configuration: !System Description "Dell Networking N2048, 6.0.0.0, Linux 3.6.5858bcf6e" !System Software Version 6.0.0.0 ! configure hostname "LAG-SW" slot 1/0 5 ! Dell Networking N2048 stack member 1 8 ! N2048 exit interface vlan 1 ip address dhcp exit spanning-tree mode mst spanning-tree mst configuration instance 1 add vlan 10-17 exit ! interface Gi1/0/1 channel-group 1 mode active exit ! interface Gi1/0/2 channel-group 1 mode active exit ! interface Gi1/0/3 970 Configuring Link Aggregation channel-group 1 mode active exit ! interface Gi1/0/4 channel-group 1 mode active exit ! interface port-channel 1 switchport mode trunk exit snmp-server engineid local 800002a203001ec9deb777 snmp-server agent boot count 3 exit Cisco 3750 MLAG Partner Configuration Current configuration : 1913 bytes ! version 12.2 no service pad service timestamps debug datetime msec service timestamps log datetime msec no service password-encryption service unsupported-transceiver ! hostname Switch ! boot-start-marker boot-end-marker ! ! no aaa new-model switch 1 provision ws-c3750g-24ts system mtu routing 1500 ip subnet-zero ! ! spanning-tree mode mst spanning-tree extend system-id ! spanning-tree mst configuration instance 1 vlan 10-17 ! ! vlan internal allocation policy ascending Configuring Link Aggregation 971 ! ! interface Port-channel1 switchport trunk encapsulation dot1q switchport mode trunk ! interface GigabitEthernet1/0/1 ! interface GigabitEthernet1/0/2 ! interface GigabitEthernet1/0/3 ! interface GigabitEthernet1/0/4 ! interface GigabitEthernet1/0/5 ! interface GigabitEthernet1/0/6 ! interface GigabitEthernet1/0/7 ! interface GigabitEthernet1/0/8 ! interface GigabitEthernet1/0/9 ! interface GigabitEthernet1/0/10 ! interface GigabitEthernet1/0/11 ! interface GigabitEthernet1/0/12 ! interface GigabitEthernet1/0/13 ! interface GigabitEthernet1/0/14 ! interface GigabitEthernet1/0/15 ! interface GigabitEthernet1/0/16 ! interface GigabitEthernet1/0/17 ! interface GigabitEthernet1/0/18 ! interface GigabitEthernet1/0/19 ! interface GigabitEthernet1/0/20 ! 972 Configuring Link Aggregation interface GigabitEthernet1/0/21 ! interface GigabitEthernet1/0/22 ! interface GigabitEthernet1/0/23 ! interface GigabitEthernet1/0/24 ! interface GigabitEthernet1/0/25 description "MLAG-Peer-Link" switchport trunk encapsulation dot1q switchport mode trunk channel-group 1 mode active ! interface GigabitEthernet1/0/26 description "MLAG-Peer-Link" switchport trunk encapsulation dot1q switchport mode trunk channel-group 1 mode active ! interface GigabitEthernet1/0/27 ! interface GigabitEthernet1/0/28 ! interface Vlan1 no ip address ! ip classless ip http server ip http secure-server ! ! control-plane ! ! line con 0 line vty 5 15 ! end Configuring Link Aggregation 973 Status Reporting The following shows the status of various components of the switches in the above configuration. The switch prompts identify the switch on which the status is shown. To obtain accurate status, the commands below are run on the primary MLAG switch unless noted otherwise. Spanning Tree Status Old-Iron-3750#show spanning-tree MST0 Spanning tree enabled protocol mstp Root ID Priority 32768 Address 0013.c4bd.f080 This bridge is the root Hello Time 2 sec Max Age 20 sec Bridge ID Priority Address Hello Time Forward Delay 15 sec 32768 (priority 32768 sys-id-ext 0) 0013.c4bd.f080 2 sec Max Age 20 sec Forward Delay 15 sec Interface Role Sts Cost Prio.Nbr Type ------------------- ---- --- --------- -------- ------------------------------Po1 Desg FWD 10000 128.488 P2p Bound(STP) MST1 Spanning tree enabled protocol mstp Root ID Priority 32769 Address 0013.c4bd.f080 This bridge is the root Hello Time 2 sec Max Age 20 sec Bridge ID Priority Address Hello Time Forward Delay 15 sec 32769 (priority 32768 sys-id-ext 1) 0013.c4bd.f080 2 sec Max Age 20 sec Forward Delay 15 sec Interface Role Sts Cost Prio.Nbr Type ------------------- ---- --- --------- -------- ------------------------------Po1 Desg FWD 10000 128.488 P2p Bound(STP) 974 Configuring Link Aggregation LAG-SW#show spanning-tree Spanning tree Enabled BPDU flooding Disabled Portfast BPDU filtering Disabled mode mst CST Regional Root: 80:00:00:1E:C9:DE:B7:77 Regional Root Path Cost: 0 ###### MST 0 Vlan Mapped: 1 ROOT ID Priority 32768 Address 0013.C4BD.F080 Path Cost 5000 Root Port Po1 Hello Time 2 Sec Max Age 20 sec Forward Delay 15 sec Bridge Max Hops 20 Bridge ID Priority 32768 Address 001E.C9DE.B777 Hello Time 2 Sec Max Age 20 sec Forward Delay 15 sec TxHoldCount 6 sec Name --------Gi1/0/1 Gi1/0/2 Gi1/0/3 Gi1/0/4 Gi1/0/5 Gi1/0/6 Gi1/0/7 Gi1/0/8 Gi1/0/9 Gi1/0/10 Gi1/0/11 Gi1/0/12 Gi1/0/13 Gi1/0/14 Gi1/0/15 Gi1/0/16 Gi1/0/17 Gi1/0/18 Gi1/0/19 Gi1/0/20 Gi1/0/21 Gi1/0/22 State -------Enabled Enabled Enabled Enabled Enabled Enabled Enabled Enabled Enabled Enabled Enabled Enabled Enabled Enabled Enabled Enabled Enabled Enabled Enabled Enabled Enabled Enabled Prio.Nbr --------128.1 128.2 128.3 128.4 128.5 128.6 128.7 128.8 128.9 128.10 128.11 128.12 128.13 128.14 128.15 128.16 128.17 128.18 128.19 128.20 128.21 128.22 Cost --------0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Sts ---DIS DIS DIS DIS DIS DIS DIS DIS DIS DIS DIS DIS DIS DIS DIS DIS DIS DIS DIS DIS DIS DIS Role ----Disb Disb Disb Disb Disb Disb Disb Disb Disb Disb Disb Disb Disb Disb Disb Disb Disb Disb Disb Disb Disb Disb RestrictedPort -------------No No No No No No No No No No No No No No No No No No No No No No Configuring Link Aggregation 975 Gi1/0/23 Gi1/0/24 Gi1/0/25 Gi1/0/26 Gi1/0/27 Gi1/0/28 Gi1/0/29 Gi1/0/30 Gi1/0/31 Gi1/0/32 Gi1/0/33 Gi1/0/34 Gi1/0/35 Gi1/0/36 Gi1/0/37 Gi1/0/38 Gi1/0/39 Gi1/0/40 Gi1/0/41 Gi1/0/42 Gi1/0/43 Gi1/0/44 Gi1/0/45 Gi1/0/46 Gi1/0/47 Gi1/0/48 Te1/0/1 Te1/0/2 Tw1/0/1 Tw1/0/2 Po1 Po2 Po3 Po4 Po5 Po6 Po7 Po8 Po9 Po10 Po11 Po12 Po13 Po14 Po15 Po16 976 Enabled Enabled Enabled Enabled Enabled Enabled Enabled Enabled Enabled Enabled Enabled Enabled Enabled Enabled Enabled Enabled Enabled Enabled Enabled Enabled Enabled Enabled Enabled Enabled Enabled Enabled Enabled Enabled Enabled Enabled Enabled Enabled Enabled Enabled Enabled Enabled Enabled Enabled Enabled Enabled Enabled Enabled Enabled Enabled Enabled Enabled 128.23 128.24 128.25 128.26 128.27 128.28 128.29 128.30 128.31 128.32 128.33 128.34 128.35 128.36 128.37 128.38 128.39 128.40 128.41 128.42 128.43 128.44 128.45 128.46 128.47 128.48 128.49 128.50 128.51 128.52 96.650 96.651 96.652 96.653 96.654 96.655 96.656 96.657 96.658 96.659 96.660 96.661 96.662 96.663 96.664 96.665 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 5000 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Configuring Link Aggregation DIS DIS DIS DIS DIS DIS DIS DIS DIS DIS DIS DIS DIS DIS DIS DIS DIS DIS DIS DIS DIS DIS DIS DIS DIS DIS DIS DIS DIS DIS FWD DIS DIS DIS DIS DIS DIS DIS DIS DIS DIS DIS DIS DIS DIS DIS Disb Disb Disb Disb Disb Disb Disb Disb Disb Disb Disb Disb Disb Disb Disb Disb Disb Disb Disb Disb Disb Disb Disb Disb Disb Disb Disb Disb Disb Disb Root Disb Disb Disb Disb Disb Disb Disb Disb Disb Disb Disb Disb Disb Disb Disb No No No No No No No No No No No No No No No No No No No No No No No No No No No No No No No No No No No No No No No No No No No No No No Po17 Po18 Po19 Po20 Po21 Po22 Po23 Po24 Po25 Po26 Po27 Po28 Po29 Po30 Po31 Po32 Po33 Po34 Po35 Po36 Po37 Po38 Po39 Po40 Po41 Po42 Po43 Enabled Enabled Enabled Enabled Enabled Enabled Enabled Enabled Enabled Enabled Enabled Enabled Enabled Enabled Enabled Enabled Enabled Enabled Enabled Enabled Enabled Enabled Enabled Enabled Enabled Enabled Enabled 96.666 96.667 96.668 96.669 96.670 96.671 96.672 96.673 96.674 96.675 96.676 96.677 96.678 96.679 96.680 96.681 96.682 96.683 96.684 96.685 96.686 96.687 96.688 96.689 96.690 96.691 96.692 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 DIS DIS DIS DIS DIS DIS DIS DIS DIS DIS DIS DIS DIS DIS DIS DIS DIS DIS DIS DIS DIS DIS DIS DIS DIS DIS DIS Disb Disb Disb Disb Disb Disb Disb Disb Disb Disb Disb Disb Disb Disb Disb Disb Disb Disb Disb Disb Disb Disb Disb Disb Disb Disb Disb No No No No No No No No No No No No No No No No No No No No No No No No No No No MLAG-Peer-A#show spanning-tree Spanning tree Enabled BPDU flooding Disabled Portfast BPDU filtering Disabled mode mst CST Regional Root: 80:00:00:13:C4:BD:F0:80 Regional Root Path Cost: 200 ###### MST 0 Vlan Mapped: 1, 100 ROOT ID Priority 32768 Address 0013.C4BD.F080 Path Cost 0 Root Port Po3 Hello Time 2 Sec Max Age 20 sec Forward Delay 15 sec Bridge Max Hops 20 Bridge ID Priority 32768 Address 001E.C9DE.C52B Configuring Link Aggregation 977 Hello Time 2 Sec Max Age 20 sec Forward Delay 15 sec TxHoldCount 6 sec Name --------Gi1/0/1 Gi1/0/2 Gi1/0/3 Gi1/0/4 Gi1/0/5 Gi1/0/6 Gi1/0/7 Gi1/0/8 Gi1/0/9 Gi1/0/10 Gi1/0/11 Gi1/0/12 Gi1/0/13 Gi1/0/14 Gi1/0/15 Gi1/0/16 Gi1/0/17 Gi1/0/18 Gi1/0/19 Gi1/0/20 Gi1/0/21 Gi1/0/22 Gi1/0/23 Gi1/0/24 Te1/0/1 Te1/0/2 Tw1/0/1 Tw1/0/2 Po1 Po2 Po3 Po4 State -------Enabled Enabled Enabled Enabled Enabled Enabled Enabled Enabled Enabled Enabled Enabled Enabled Enabled Enabled Enabled Enabled Enabled Enabled Enabled Enabled Enabled Enabled Enabled Enabled Enabled Enabled Enabled Enabled Disabled Enabled Enabled Enabled Prio.Nbr --------128.1 128.2 128.3 128.4 128.5 128.6 128.7 128.8 128.9 128.10 128.11 128.12 128.13 128.14 128.15 128.16 128.17 128.18 128.19 128.20 128.21 128.22 128.23 128.24 128.25 128.26 128.27 128.28 96.650 96.651 96.652 96.653 Cost --------0 0 0 0 0 0 0 20000 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 5000 200 0 Sts ---DIS DIS DIS DIS DIS DIS DIS FWD DIS DIS DIS DIS DIS DIS DIS DIS DIS DIS DIS DIS DIS DIS DIS DIS DIS DIS DIS DIS FWD FWD FWD DIS Role ----Disb Disb Disb Disb Disb Disb Disb Desg Disb Disb Disb Disb Disb Disb Disb Disb Disb Disb Disb Disb Disb Disb Disb Disb Disb Disb Disb Disb Disb Desg Root Disb RestrictedPort -------------No No No No No No No No No No No No No No No No No No No No No No No No No No No No No No No No MLAG Status MLAG-Peer-A#show vpc brief VPC config Mode................................ Enabled Keepalive config mode.......................... Enabled VPC operational Mode........................... Enabled 978 Configuring Link Aggregation Self Role...................................... Primary Peer Role...................................... Secondary Peer detection................................. Peer detected, VPC Operational Peer-Link details ----------------Interface...................................... Po1 Peer link status............................... UP Peer-link STP Mode............................. Disabled Configured Vlans............................... 1,10,11,12,13,14,15,16,17 Egress tagging................................. 10,11,12,13,14,15,16,17 VPC Details ----------Number of VPCs configured...................... 2 Number of VPCs operational..................... 2 VPC id# 1 ----------Interface...................................... Po2 Configured Vlans............................... 1,10,11,12,13,14,15,16,17 VPC Interface State............................ Active Local MemberPorts ----------------Gi1/0/23 Gi1/0/24 Status -----UP UP Peer MemberPorts ---------------Gi1/0/23 Gi1/0/24 Status -----UP UP VPC id# 2 ----------Interface...................................... Po3 Configured Vlans............................... 1,10,11,12,13,14,15,16,17 VPC Interface State............................ Active Configuring Link Aggregation 979 MLAG-Peer-A#show vpc 1 VPC id# 1 ----------------Config mode.................................... Enabled Operational mode............................... Enabled Port channel................................... Po2 Local MemberPorts ----------------Gi1/0/23 Gi1/0/24 Status -----UP UP Peer MemberPorts ---------------Gi1/0/23 Gi1/0/24 Status -----UP UP MLAG-Peer-A#show vpc 2 VPC id# 2 ----------------Config mode.................................... Enabled Operational mode............................... Enabled Port channel................................... Po3 Local MemberPorts ----------------Gi1/0/1 Status -----UP Peer MemberPorts ---------------Gi1/0/1 Status -----UP MLAG-Peer-A#show vpc peer-keepalive Peer IP address................................ Source IP address.............................. UDP port....................................... Peer detection................................. Peer detection operational status.............. Peer is detected............................... 980 Configuring Link Aggregation 192.168.0.2 192.168.0.1 50000 Enabled Up TRUE MLAG-Peer-A#show vpc statistics peer-keepalive Total transmitted.............................. Tx successful.................................. Tx errors...................................... Total received................................. Rx successful.................................. Rx Errors...................................... Timeout counter................................ 20908 20908 0 20835 20835 0 1 MLAG-Peer-A#show vpc statistics peer-link Peer Peer Peer Peer Peer Peer Peer Peer Peer Peer Peer Peer Peer Peer Peer Peer Peer Peer link link link link link link link link link link link link link link link link link link control messages transmitted......... control messages Tx errors........... control messages Tx timeout.......... control messages ACK transmitted..... control messages ACK Tx errors....... control messages received............ data messages transmitted............ data messages Tx errors.............. data messages Tx timeout............. data messages received............... BPDU's transmitted to peer........... BPDU's Tx errors..................... BPDU's received from peer............ BPDU's Rx errors..................... LACPDU's tranmsitted to peer......... LACPDU's Tx errors................... LACPDU's received from peer.......... LACPDU's Rx errors................... 75 0 0 119 0 119 1294 0 0 1886 11 0 751 0 1283 0 1135 0 Configuring Link Aggregation 981 982 Configuring Link Aggregation 29 Configuring Data Center Bridging Features This chapter describes how to manage the features developed for use in data center environments but often used in a variety of 10G applications. NOTE: The data center fatures described in this chapter are available on the Dell Networking N4000 switches only. The topics covered in this chapter include: • Data Center Bridging Technology Overview • Priority Flow Control (PFC) • DCB Capability Exchange (DCBX) • Enhanced Transmission Selection (ETS) Data Center Bridging Technology Overview The Dell Networking N4000 switches support Data Center Bridging (DCB) features to increase the reliability of Ethernet-based networks in the data center. The N4000 switches support PFC, ETS, and DCBX capability exchange, with the ability to autoconfigure from a peer switch. The Ethernet enhancements that DCB provides are well suited for iSCSI applications. Table 29-1 provides a summary of the features this chapter describes. Table 29-1. Data Center Features Feature Description PFC Provides a way to distinguish which traffic on a physical link is paused when congestion occurs based on the priority of the traffic. Configuring Data Center Bridging Features 983 Table 29-1. Data Center Features (Continued) Feature Description DCBx Allows DCB devices to exchange configuration information, using type-length-value (TLV) information elements over LLDP, with directly connected peers. ETS Supports the ETS configuration and Application Priority TLVs, which are accepted from auto-upstream devices and propagated to auto-downstream devices. The N4000 switches support the automatic configuration of the switch with received ETS parameters. Default DCB Values Table 29-2 lists the default values for the DCB features that this chapter describes. Table 29-2. Default Port-Based Traffic Control Values Feature Default PFC Disabled, no priority classifications are configured. DCBx version Auto detect 984 Configuring Data Center Bridging Features Priority Flow Control Ordinarily, when flow control is enabled on a physical link, it applies to all traffic on the link. When congestion occurs, the hardware sends pause frames that temporarily suspend traffic flow to help prevent buffer overflow and dropped frames. PFC provides a means of pausing individual priorities within a single physical link. By pausing the congested priority or priorities independently, protocols that are highly loss-sensitive can share the same link with traffic that has different loss tolerances. This feature is used in networks where the traffic has differing loss tolerances. For example, Fibre Channel traffic is highly sensitive to traffic loss. If a link contains both loss-sensitive data and other less loss-sensitive data, the losssensitive data should use a no-drop priority that is enabled for flow control. Priorities are differentiated by the priority field of the IEEE 802.1Q VLAN header, which identifies an IEEE 802.1p priority value. These priority values must be mapped to internal class-of-service (CoS) values. The PFC feature allows you to specify the CoS values that should be paused (due to greater loss sensitivity) instead of dropped when congestion occurs on a link. Unless configured as no-drop, all CoS priorities are considered nonpausable (“drop”) when priority-based flow control is enabled until no-drop is specifically turned on. PFC Operation and Behavior PFC uses a control packet newly defined in IEEE 802.1Qbb and, therefore, is not compatible with IEEE 802.3 Annex 31B flow control. An interface that is configured for PFC is automatically disabled for flow control. When PFC is disabled on an interface, the flow control configuration for the interface becomes active. Any IEEE 802.3 Annex 31B link-layer flow-control frames received on a PFC configured interface are ignored. Each priority is configured as either drop or no-drop. If a priority that is designated as no-drop is congested, the priority is paused. Drop priorities do not participate in pause. You must configure the same no-drop priorities and enable VLAN tagging for the no-drop priorities across the network to ensure end-to-end lossless behavior. Configuring Data Center Bridging Features 985 Operator configuration of PFC is used only when the port is configured in a manual role. When interoperating with other equipment in a manual role, the peer equipment must be configured with identical PFC priorities and VLAN assignments. Interfaces not enabled for PFC ignore received PFC frames. Ports configured in auto-upstream or auto-downstream roles receive their PFC configuration from the configuration source and ignore any manually configured information. When using links in a port-channel, PFC must be configured on all of the individual links in the port-channel, as it operates on a link-local basis. NOTE: This feature is configurable on physical full duplex interfaces only. To enable PFC on a LAG interface, the member interfaces must have the same configuration. When PFC is disabled, the interface defaults to the IEEE 802.3 Annex 31B flow control setting for the interface. PFC is disabled by default. If you enable priority-based flow control for a particular priority value on an interface, ensure that VLAN tagging is enabled on the interface so that the 802.1p priority values are carried through the network (see "VLAN Tagging" on page 649). Additionally, make sure that 802.1p priority values are mapped to CoS values (see "Configuring Class-of-Service" on page 1313). If DCBX is enabled, the manually configured PFC parameters (no-drop priorities) must match the peers PFC parameters. If they do not match, PFC will not be operationally enabled and the port will continue to operate in the configured legacy flow control mode (IEEE 802.3 Annex 31B mode or none). PFC can be configured using the web interface and the command line interface. Configuring PFC Using the Web Interface This section provides information about the OpenManage Switch Administrator pages to use to view and configure PFC on N4000 series switches. For details about the fields on a page, click at the top of the page. 986 Configuring Data Center Bridging Features PFC Configuration Page Use the PFC Configuration page to enable priority flow control on one or more interfaces and to configure which priorities are subject to being paused to prevent data loss. To display the PFC Configuration page, click Switching → PFC → PFC Configuration in the navigation menu. Figure 29-1. PFC Configuration PFC Statistics Page Use the PFC Statistics page to view the PFC statistics for interfaces on the switch. To display the PFC Statistics page, click Switching → PFC → PFC Statistics in the navigation menu. Configuring Data Center Bridging Features 987 Figure 29-2. PFC Statistics Configuring PFC Using the CLI Beginning in Privileged EXEC mode, use the following commands to configure PFC. NOTE: If DCBx is enabled and the switch is set to autoconfigure from a DCBX peer, configuring PFC is not necessary because the DCBx protocol automatically configures the PFC parameters. Command Purpose configure Enter global configuration mode. 988 Configuring Data Center Bridging Features Command Purpose interface interface Enter interface configuration mode for the specified interface. The interface variable includes the interface type and number, for example tengigabitethernet 1/0/3. You can also specify a range of interfaces with the interface range command, for example, interface range tengigabitethernet 1/0/8-12 configures interfaces 8, 9, 10, 11, and 12. datacenter-bridging priority-flow-control mode on Enter the Data Center Bridging mode. PFC commands are issued from within this mode. Enable PFC on the interface(s) NOTE: It is unnecessary to set the priority flow control to enable if the lldp dcbx port-role auto-down or lldp dcbx portrole auto-up command has already been applied. priority-flow-control Use the no-drop option to enable the priority group for priority priority-id {drop lossless behavior. To enable lossy behavior, use the drop | no-drop} form of the command. priority-id — Specify the IEEE 802.1p priority value (range: 0–7) NOTE: Only two queues can be set to no-drop at one time. CTRL + Z Exit to Privileged EXEC mode. Display the datacenter-bridging configuration, status and show interfaces counters for a given interface. datacenter-bridging [interface | port-channel port-channel-id] Clear all PFC statistics or the PFC statistics for the clear priority-flowcontrol statistics specified interface. [interface | port-channel port-channel-id] Configuring Data Center Bridging Features 989 PFC Configuration Example The network in this example handles both data and voice traffic. Because the voice traffic is time sensitive, it requires a higher priority than standard data traffic. The voice traffic uses VLAN 100 and has an 802.1p priority of 5, which is mapped to hardware queue 4. IP phones are connected to ports 3, 5, and 10, so PFC is enabled on these ports with 802.1p priority 5 traffic as no-drop. The configuration also enables VLAN tagging so that the 802.1p priority is identified. This example assumes the voice VLAN (VLAN 100) has already been configured. The administrator may need to perform other configuration steps to ensure suitable network operation, including configuring the bandwidth allocation for the drop and no-drop priorities or to enable or disable the DCBX protocol. CAUTION: All ports may be briefly shutdown when modifying either flow control (FC) or PFC settings. PFC uses a control packet defined in 802.1Qbb and is not compatible with IEEE 802.3 Annex 31B flow control. 1 Map 802.1p priority 5 to traffic class 4. The following command changes the priority to traffic class mapping to be one-to-one, based upon the default switch settings. For lossless service, a priority must be mapped oneto-one to a traffic class. For more information about traffic classes, see "Configuring Class-of-Service" on page 1313. For a complete example of manually configuring a N4000 switch for iSCSI with PFC, refer to "iSCSI Optimization Configuration Examples" on page 473. console#configure console(config)#classofservice dot1p-mapping 5 4 2 Enter Interface Configuration mode for ports 3, 5, and 10, and then enter Data Center Bridging mode for these ports. console(config)#interface range te1/0/3, te1/0/5, te1/0/10 console(config-if)#datacenter-bridging 3 Enable PFC and configure traffic marked with 802.1p priority 5 to be paused rather than dropped when congestion occurs. console(config-dcb)#priority-flow-control mode on console(config-dcb)#priority-flow-control priority 5 no-drop 990 Configuring Data Center Bridging Features console(config-dcb)#exit 4 Enable VLAN tagging on the ports so the 802.1p priority is identified. Trunk mode can also be enabled on port-channels. console(config-if)#switchport mode trunk console(config-if)#exit Configuring Data Center Bridging Features 991 DCB Capability Exchange The Data Center Bridging Exchange Protocol (DCBx) is used by DCB devices to exchange configuration information with directly connected peers. DCBx uses type-length-value (TLV) information elements over LLDP to exchange information, so LLDP must be enabled on the port to enable the information exchange. By default, LLDP is enabled on all ports. For more information, see "Discovering Network Devices" on page 761. The main objective of DCBx is to perform the following operations: • Discovery of DCB capability in a peer: DCBx is used to learn about the capabilities of the peer device. It is a means to determine if the peer device supports a particular feature such as PFC. • DCB feature misconfiguration detection: DCBx can be used to detect misconfiguration of a feature between the peers on a link. Misconfiguration detection is feature-specific because some features may allow asymmetric configuration. • Peer configuration of DCB features: DCBx can be used by a device to perform configuration of DCB features in its peer device if the peer device is willing to accept configuration. For discussion and examples of configuring iSCSI with DCBX, refer to "Configuring iSCSI Optimization" on page 459. The DCBx protocol supports the propagation of configuration information for the following features: • Enhanced Transmission Selection (ETS) • Priority-based Flow Control (PFC) • Application Priorities These features use DCBx to send and receive device configuration and capability information to the peer DCBx device. The Application Priorities information is simply captured from the peer and potentially propagated to other peers by the DCBx component, as well as being configured when iSCSI is enabled on an operationally active PFC port. DCBX information is carried over LLDP, which is a link-local protocol. When configuring links in a port-channel to use DCBX, the DCBX settings should be the same for all links in the port-channel. 992 Configuring Data Center Bridging Features Interoperability with IEEE DCBx To be interoperable with legacy industry implementations of the DCBx protocol, The Dell Networking N4000 switches use a hybrid model to support both the IEEE version of DCBx (IEEE 802.1Qaz) and legacy DCBx versions. The N4000 switch automatically detects whether a peer is operating with either of the two CEE DCBx versions or the IEEE standard DCBx version (the default mode). You can also configure DCBx to manually select one of the legacy versions or IEEE standard mode. In auto-detect mode, the switch starts operating in IEEE DCBx mode on a port, and if it detects a legacy DCBx device based on the OUI of the organization TLV, then the switch changes its DCBx mode on that port to support the version detected. There is no timeout mechanism to move back to IEEE mode. If the DCBx peer times out, multiple peers are detected, the link is reset (link down/up) or if commanded by the operator, DCBx resets its operational mode to IEEE. The interaction between the DCBx component and other components remains the same irrespective of the operational mode it is executing. For instance, the DCBx component interacts with PFC to get needed information to pack the TLVs to be sent out on the interface. Based on the operational control mode of the port, DCBx packs it in the proper frame format. DCBx and Port Roles The behavior of each port is dependent on its operational mode and that of other ports in the stack. The port mode is a DCBx configuration item that is passed to the DCBx clients to control the processing of their configuration information. There are four port roles: 1 Manual 2 Auto-Upstream 3 Auto-Downstream 4 Configuration Source Ports operating in the manual role do not have their configuration affected by peer devices or by internal propagation of configuration. These ports have their operational mode, traffic classes, and bandwidth information specified Configuring Data Center Bridging Features 993 explicitly by the operator. These ports advertise their configuration to their peer if DCBx is enabled on that port. Incompatible peer configurations are logged and counted with an error counter. The default operating mode for each port is manual. A port that is set to manual mode sets the willing bit for DCBx client TLVs to false. Manuallyconfigured ports never internally propagate or accept internal or external configuration from other ports; in other words, a manual configuration discards any automatic configuration. Manually-configured ports may notify the operator of incompatible configurations if client configuration exchange over DCBx is enabled. Manually configured ports are always operationally enabled for DCBx clients, regardless of whether DCBx is enabled. Operationally enabled means that the port reports that it is able to operate using the current configuration. A port operating in the auto-upstream role advertises a configuration, but is also willing to accept a configuration from the link-partner and propagate it internally to the auto-downstream ports, as well as receive configuration propagated internally by other auto-upstream ports. Specifically, the willing parameter is enabled on the port and the recommendation TLV is sent to the peer and processed if received locally. The first auto-upstream port to successfully accept a compatible configuration becomes the configuration source. The configuration source propagates its configuration to other autoupstream and auto-downstream ports. Only the configuration source may propagate configuration to other ports internally. Auto-upstream ports that receive internally propagated information ignore their local configuration and utilize the internally propagated information. Peer configurations received on auto-upstream ports other than the configuration source result in one of two possibilities. If the configuration is compatible with the configuration source, then the DCBx client becomes operationally active on the upstream port. If the configuration is not compatible with the configuration source, then a message is logged indicating an incompatible configuration, an error counter is incremented, and the DCBx client is operationally disabled on the port. The expectation is that the network administrator configures the upstream devices appropriately so that all such devices advertise a compatible configuration. A port operating in the auto-downstream role advertises a configuration but is not willing to accept one from the link partner. However, the port will accept a configuration propagated internally by the configuration source. Specifically, 994 Configuring Data Center Bridging Features the willing parameter is disabled on auto-downstream. By default, autodownstream ports have the recommendation TLV parameter enabled. Autodownstream ports that receive internally propagated information ignore their local configuration and utilize the internally propagated information. Autodownstream ports propagate PFC, ETS, and application priority information received from the configuration source. In the Configuration Source role, the port has been manually selected to be the configuration source. Configuration received over this port is propagated to the other auto configuration ports, however, no automatic election of a new configuration source port is allowed. Events that cause selection of a new configuration source are ignored. The configuration received over the configuration source port is maintained until cleared by the operator (set the port to the manual role). Since it is not possible to configure the port role for a port-channel, it is recommended that the individual links have an identical port role configured on all links in the port-channel (auto-up or auto-down). Since only one port in the system can be configured as the configuration source, configuring interfaces as auto-up is a preferable alternative to a config-source setting. Configuration Source Port Selection Process When an auto-upstream or auto-downstream port receives a configuration from a peer, the DCBx client first checks if there is an active configuration source. If there is a configuration source already selected, the received configuration is checked against the local port operational values as received from the configuration source, and if compatible, the client marks the port as operationally enabled. If the configuration received from the peer is determined to not be compatible, a message is logged, an error counter is incremented and the DCBx clients become operationally disabled on the port. Operationally disabled means that PFC will not operate over the port. The port continues to keep link up and exchanges DCBx packets. If a compatible configuration is later received, the DCBx clients will become operationally enabled. If there is no configuration source, a port may elect itself as the configuration source on a first-come, first-serve basis from the set of eligible ports. A port is eligible to become the configuration source if the following conditions are true: • No other port is the configuration source. Configuring Data Center Bridging Features 995 • The port role is auto-upstream. • The port is enabled with link up and DCBx enabled. • The port has negotiated a DCBx relationship with the partner. • The switch is capable of supporting the received configuration values, either directly or by translating the values into an equivalent configuration. Whether or not the peer configuration is compatible with the configured values is NOT considered. The newly elected configuration source propagates DCBx client information to the other ports and is internally marked as being the port over which configuration has been received. Configuration changes received from the peer over the configuration source port are propagated to the other auto configuration ports. Ports receiving auto configuration information from the configuration source ignore their current settings and utilize the configuration source information. When a configuration source is selected, all auto-upstream ports other than the configuration source are marked as willing disabled. To reduce flapping of configuration information, if the configuration source port is disabled, disconnected, or loses LLDP connectivity, the system clears the selection of configuration source port (if not manually selected) and enables the willing bit on all auto-upstream ports. The configuration on the auto configuration ports is not cleared (configuration holdover). If the user wishes to clear the configuration on the system in this scenario, the user can put the configuration source port into manual mode. When a new port is selected as the configuration source, it is marked as the configuration source, the DCBx configuration is refreshed on all auto configuration ports, and each port may begin configuration negotiation with their peer again (if any information has changed). Disabling DCBX If it is desired to disable DCBX, the network operator can use the following commands to eliminate the transmission of DCBX TLVs in the LLDP frames on an interface: no lldp tlv-select dcbxp application-priority no lldp tlv-select dcbxp congestion-notification no lldp tlv-select dcbxp ets-config 996 Configuring Data Center Bridging Features no lldp tlv-select dcbxp ets-recommend no lldp tlv-select dcbxp pfc These commands eliminate only the DCBX TLVs from use by LLDP. They do not otherwise affect any manually configured DCBX capabilities or the normal operation of LLDP. Configuring DCBx You can use the CLI to configure DCBX on N4000 switches. Beginning in Privileged EXEC mode, use the following commands to configure DCBx. Command Purpose configure Enter global configuration mode. lldp dcbx version {auto | cin | cee | ieee} Optionally configure the administrative version for the DCBx protocol: • auto—Automatically select the version based on the peer response (default) • cin—Force the mode to Cisco-Intel-Nuova. (DCBx 1.0) • cee—Force the mode to CEE (DCBx 1.06) • ieee—Force the mode to IEEE 802.1Qaz lldp tlv-select dcbxp [pfc | applicationpriority] Enable LLDP to send specific DCBx TLVs if LLDP is enabled to transmit on the given interface. Entering the command with no parameters enables transmission of all TLVs. • pfc—Transmit the PFC configuration TLV • application-priority—Transmit the application priority TLV interface interface Enter interface configuration mode for the specified interface. The interface variable includes the interface type and number, for example tengigabitethernet 1/0/3. You can also specify a range of interfaces with the interface range command, for example, interface range tengigabitethernet 1/0/8-12 configures interfaces 8, 9, 10, 11, and 12. Configuring Data Center Bridging Features 997 Command Purpose lldp tlv-select dcbxp [pfc | applicationpriority] Override the global configuration for the LLDP DCBx TLVs on this interface. Entering the command with no parameters enables transmission of all TLVs. • pfc—Transmit the PFC configuration TLV. • application-priority—Transmit the application priority TLV. lldp dcbx port-role Configure the DCBx port role on the interface: {auto-up |auto-down | • auto-up—Advertises a configuration, but is also willing to manual | configurationaccept a configuration from the link-partner and source} propagate it internally to the auto-downstream ports as well as receive configuration propagated internally by other auto-upstream ports. These ports have the willing bit enabled. These ports should be connected to FCFs. • auto-down—Advertises a configuration but is not willing to accept one from the link partner. However, the port will accept a configuration propagated internally by the configuration source. These ports have the willing bit set to disabled. Selection of a port based upon compatibility of the received configuration is suppressed. These ports should be connected to a trusted FCF. • manual—Ports operating in the Manual role do not have their configuration affected by peer devices or by internal propagation of configuration. These ports will advertise their configuration to their peer if DCBx is enabled on that port. The willing bit is set to disabled on manual role ports. • configuration-source—In this role, the port has been manually selected to be the configuration source. Configuration received over this port is propagated to the other auto configuration ports. Selection of a port based upon compatibility of the received configuration is suppressed. These ports should be connected to a trusted FCF. These ports have the willing bit enabled. CTRL + Z 998 Exit to Privileged EXEC mode. Configuring Data Center Bridging Features Command Purpose Display the interface TLV configuration for all interfaces show lldp tlv-select interface {all |interface} or for the specified interface. show lldp dcbx interface Display the interface TLV configuration for all interfaces {all status |interface or for the specified interface. [detail]} Enhanced Transmission Selection Networks classify and prioritize traffic to provide different service characteristics to end user traffic flows. Administrators may wish to guarantee or limit bandwidth for certain traffic, ensure lossless behavior for other traffic, and control the queue discipline/drop characteristics for best-effort traffic. Additionally, it is desirable for a switch to support sharing bandwidth among bursty sources while still enabling prioritization of time-sensitive or management traffic that requires minimum latency. Enhanced transmission selection (ETS) provides uniform management for sharing bandwidth between congestion managed and traditional classes on a single bridged network. Using priority-based processing and weight allocations, Traffic Class Groups (TCGs) carrying different types of traffic such as LAN, SAN, and management traffic can be configured to provide minimum bandwidth guarantees, unused bandwidth sharing, and lossless or best-effort transmit characteristics. Dell Networking N4000 switches support strict priority and Weighted Deficit Round Robin (WDRR) scheduling with up to two lossless traffic classes. WDRR schedules traffic based on average bandwidth consumed vs. frame counts. ETS Operation The normal (default) operation of Dell Networking switches, when uncongested, is that packets are scheduled for output in the order in which they are received, that is, using FIFO scheduling. The class of service (CoS) mechanism enables the administrator to schedule packets for output ahead of other packets when the switch is congested, choose which type of packets to drop when the switch is congested, and assign a minimum bandwidth guarantee to ensure scheduling fairness. These mechanisms operate at the CoS queue level; that is, the minimum bandwidth guarantees are made across all configured CoS queues. Configuring Data Center Bridging Features 999 NOTE: Minimum bandwidth guarantees and scheduling mechanisms apply only when the switch is congested. When the switch is not congested, packets egress the switch as soon as they are received. ETS provides a second level of scheduling for packets selected for transmission by the CoS scheduler. ETS operates at the traffic class group (TCG) level and supports sharing of bandwidth across TCGs, bandwidth assignment for each TCG, and queue discipline (drop behavior) for each TCG. N4000 switches support three TCGs internally, up to two of which may be configured as lossless. When a packet arrives on an ingress port, it is forwarded to the appropriate CoS queue based upon the dot1p mapping. The dot1p mapping maps the user priority contained in the received VLAN Priority Tag to the traffic class or uses the default port assignment. A traffic class identifies a particular CoS queue. If the ingress port is configured to use 802.1p CoS mapping and the port is configured to trust the user priority value in the received frame, then the frame is forwarded to the appropriate CoS queue per its 802.1p user priority value. At the first level of egress scheduling, each of the configured attributes of a CoS queue, namely scheduler algorithm, min-bandwidth and drop mechanism, are honored, and the packet is either dropped or forwarded to next level. Only frames selected by the first level scheduler are forwarded to the second level. Strict priority traffic classes are serviced first in order of traffic class number. A strict priority traffic class is one that is configured as strict priority or has a traffic class group weight of 0 (unlimited bandwidth). Within a strict priority traffic class, frames are serviced (as determined by the traffic class number) in CoS queue priority order from the highest (6) to the lowest (0). Each traffic class has an internal weight equal to the traffic class number plus one. After the strict priority traffic classes have been serviced, the remaining traffic classes are serviced according to their internal weight. For example, if CoS queues 0, 1, and 2 have an equal offered load toward a congested output port, CoS queue 2 will receive 3/6 of the bandwidth, CoS queue 1 will receive 2/6 of the bandwidth, and CoS queue 0 will receive 1/6 of the bandwidth. 1000 Configuring Data Center Bridging Features The minimum bandwidth setting can be used to override the strict priority and weighted settings. The highest numbered strict priority queue will receive no more bandwidth than 100 percent minus the sum of the minimum bandwidth percentages assigned to the other queues. If used, it is recommended that minimum bandwidth percentages only be set high enough to ensure a minimum level of service for any queue; i.e., the sum of the minimum bandwidth percentages is a fraction of 100%. This ensures that the system can respond to bursts in traffic. Setting the minimum bandwidths such that they sum to 100% effectively sets the scheduler such that no queue can exceed its minimum bandwidth percentage when congestion occurs. NOTE: CoS queue 7 is reserved for internal traffic. Non-strict priority CoS queues are serviced with WDRR scheduling using the bandwidth available after strict priority traffic is serviced. Each CoS queue in the first level scheduler is mapped to one of the three traffic class groups in the second level scheduler. There, frames are serviced using the TCG configuration. The minimum bandwidth guarantee is first calculated across the TCGs. Strict priority TCGs are scheduled first but have their bandwidth reduced by the minimum bandwidth guarantees configured on other TCGs. Strict priority TCGs are scheduled from highest numbered TCG to lowest. When all TCGs have met their minimum bandwidth limits (or the queues are empty), TCGs that have not met their maximum bandwidth limit are scheduled. Once the limits for a TCG are satisfied (maximum bandwidth, no frames available for transmission, etc.), the scheduler moves to the next TCG. If no minimum or maximum bandwidth limits are configured, TCGs are serviced by the second-level scheduler using the configured TCG weights to define the relative bandwidth allocation among the TCGs. When an egress port is congested, packets are selected for discard using the configured taildrop or WRED discipline. Minimum TCG bandwidth, maximum TCG bandwidth, and TCG weights are metered to within approximately 3% of the link bandwidth. In the case that all TCGs are configured as strict priority, inter-TCG scheduling reverts to Weighted Deficit Round Robin scheduling based on the configured TCG weights. Configuring Data Center Bridging Features 1001 Commands This section provides information about the commands you use to manually configure and monitor ETS. For more information about the commands, see the Dell Networking N2000, N3000, and N4000 Series Switches CLI Reference Guide at support.dell.com/manuals. On N4000 switches, the following steps are not required if using the DCBX protocol to obtain ETS configuration from an auto-configuration source. For information on configuring iSCSI and DCBX, refer to "Configuring iSCSI Optimization" on page 459. Command Purpose classofservice trafficclass-group Maps the internal Traffic Class to an internal Traffic Class Group (TCG). The Traffic Class can range from 0-6, although the actual number of available traffic classes depends on the platform. traffic-class-group maxbandwidth Specifies the maximum transmission bandwidth limit for each TCG as a percentage of the interface rate. Also known as rate shaping, this has the effect of smoothing temporary traffic bursts over time so that the transmitted traffic rate is bound. traffic-class-group minbandwidth Specifies the minimum transmission bandwidth guaranteed for each TCG before processing frames from lower numbered TCGs on an interface. traffic-class-group strict Activates the strict priority scheduler mode for each specified TCG. traffic-class-group weight Specifies the scheduling weight for each TCG. The scheduler attempts to balance the traffic selected for transmission from the TCGs such that, when the switch is congested, traffic is selected from the round robin configured TCGs in proportion to their weights. show classofservice traffic-class-group Displays the Traffic Class to Traffic Class Group mapping. show interfaces trafficclass-group Displays the Traffic Class to Traffic Class Group mapping 1002 Configuring Data Center Bridging Features ETS Configuration Example This example configures four classes of traffic: Best effort traffic CoS Queue 0 for untagged and VLAN-tagged frames with VPTs 0, 1, and 2 Lossless iSCSI traffic CoS Queues 1 & 2 for VLAN tagged frames with VPTs 3 & 4 respectively Expedited traffic CoS Queue 3 on VLAN tagged frames with VPTs 5, 6, and 7 1. Enable Trust Mode on an Interface The following command enables the use of the dot1p priority of the incoming packet. It may be configured on a single interface, a range of interfaces or all interfaces. By default, ports are configured to trust the incoming user priority. console(config-if-Te1/0/1)#classofservice trust dot1p To show the configured trust mode on an interface, use the following command: console#show classofservice trust tengigabitethernet 1/0/1 Class of Service Trust Mode: Dot1P 2. Map Dot1p Priority to CoS Queues This step maps dot1p priorities to the CoS queues. This mapping places the incoming packet in the selected CoS queue based on the dot1p priority. It may be configured on a single interface, a range of interfaces, or all interfaces. To ensure lossless behavior, the dot1p priority must be mapped one to one to a CoS queue for the lossless priorities. Up to two lossless priorities may be configured on N4000 switches. CoS queue 7 is reserved by the system and is not assignable. It is generally recommended that the administrator utilize CoS queues 0-3 as CoS queues 4-6 may be utilized by the system for other types of system traffic, e.g. routing protocol PDU handling. Frames with different user priorities assigned to a single CoS queue receive equal treatment. This example maps user priorities 0, 1, and 2 to CoS queue 0 (background or best effort traffic), user priorities 3 and 4 to CoS queues 1 and 2 (iSCSI traffic), and all other priorities to CoS queue 2 (low latency and network control traffic). Configuring Data Center Bridging Features 1003 console(config-if-Te1/0/2)#classofservice console(config-if-Te1/0/2)#classofservice console(config-if-Te1/0/2)#classofservice console(config-if-Te1/0/2)#classofservice console(config-if-Te1/0/2)#classofservice console(config-if-Te1/0/2)#classofservice console(config-if-Te1/0/2)#classofservice console(config-if-Te1/0/2)#classofservice dot1p-mapping dot1p-mapping dot1p-mapping dot1p-mapping dot1p-mapping dot1p-mapping dot1p-mapping dot1p-mapping 0 1 2 3 4 5 6 7 0 0 0 1 2 3 3 3 To show dot1p priority for an interface, use the following command: console#show classofservice dot1p-mapping tengigabitethernet 1/0/1 User Priority ------------0 1 2 3 4 5 6 7 Traffic Class ------------0 0 0 1 2 3 3 3 3. Configure Minimum Bandwidth on the CoS Queues (optional) This step configures the minimum bandwidth guarantee for each CoS queue when the switch is congested. If the switch is not congested, this setting has no effect. The min-bandwidth setting guarantees that any particular CoS queue is serviced often enough to ensure that the offered load can achieve the minimum transfer rate. The bandwidth is measured internally as bytes transferred per second. The minimum bandwidth setting is enforced on the egress queue; it does not rate-limit incoming frames. The minimum bandwidth setting is configured as a percentage of the total bandwidth and must be less than or equal to 100%. It may be configured on a single interface, a range of interfaces, or all interfaces. The minimum bandwidth setting on the CoS queues comes in to play when there is congestion among the CoS queues belonging to a single TCG. This is an optional setting and is not generally required, as the secondary scheduler has the capability of guaranteeing minimum bandwidth for a TCG. If this value is set, the sum of the individual minimum bandwidths of the CoS queues belonging to any TCG should be set to the same value as the minimum bandwidth value of the TCG in the secondary scheduler, or no minimum bandwidth value should be configured for the TCG. 1004 Configuring Data Center Bridging Features CAUTION: Sharing of bandwidth among CoS Queues is disabled if the sum of the minimum bandwidth settings equals 100%. console(config-if-Te1/0/1)#cos-queue min-bandwidth 20 35 35 10 0 0 0 4. Configure the Scheduler Mode for the CoS Queues This step enables strict priority scheduling on one or more CoS queues (traffic classes). Strict priority scheduling ensures that packets assigned to a higher CoS queue number are serviced before packets assigned to lower CoS queue numbers. The strict priority setting does not restrict frame ingress. Use the 'no' command to disable strict priority mode scheduling. It is recommended that all queues enabled for strict priority scheduling be assigned to a single strict-priority-enabled TCG other than TCG0. The following example sets CoS queue (traffic class) number 3 to be serviced with strict priority: console(config-if-Te1/0/1)#cos-queue strict 3 To show the minimum bandwidth and scheduler modes for CoS queues, use the following command. console#show interfaces cos-queue tengigabitethernet 1/0/1 Interface...................................... Te1/0/1 Interface Shaping Rate......................... 0 kbps WRED Decay Exponent............................ 9 Queue Id -------0 1 2 3 4 5 6 Min. Bandwidth -------------20 35 35 10 0 0 0 Scheduler Type -------------Weighted Weighted Weighted Strict Weighted Weighted Weighted Queue Management Type --------------------Tail Drop Tail Drop Tail Drop Tail Drop Tail Drop Tail Drop Tail Drop 5. Map the CoS Queues to TCGs In this step, CoS queues are mapped to Traffic Class Groups (TCGs). Since TCGs are serviced from highest numbered TCG to lowest, higher priority traffic should be assigned to higher numbered TCGs. In general, strict Configuring Data Center Bridging Features 1005 priority traffic (typically control plane or low bandwidth, low latency traffic) is assigned the highest numbered TCG. It is recommended that WDRR queues be assigned to TCG0. The mapping may be configured on a single interface, a range of interfaces, or all the interfaces. It is required that TCGs always be assigned in order from 0 to 2. It is further recommended that the operator always utilize consecutive TCGs starting with TCG 0; for example, use TCG 0 and 1 vs. TCG 0 and 2 only. This example assigns best effort traffic to TCG 0, lossless traffic to TCG 1, and expedited service traffic to TCG 2. console(config-if-Te1/0/1)# console(config-if-Te1/0/1)# console(config-if-Te1/0/1)# console(config-if-Te1/0/1)# classofservice classofservice classofservice classofservice traffic-class-group traffic-class-group traffic-class-group traffic-class-group 0 1 2 3 0 1 1 2 To show the CoS queue to TCG mapping, use the following command: console#show classofservice traffic-class-group tengigabitethernet 1/0/1 Traffic Class Traffic Class Group -----------------------------0 0 1 1 2 1 3 2 4 0 5 0 6 0 6. Set the Weight for Each TCG This step configures the scheduling weight for each TCG. The weight percentage configures the scheduler to ensure that each TCG is nominally serviced in the ratio specified. Each WDRR TCG should be assigned a nonzero weight. Weights may be configured on a single interface, a range of interfaces, or all interfaces, and must sum to 100%. It is recommended that strict priority TCGs be assigned a weight of 0%, since they are processed first and ignore the configured TCG weight. 1006 Configuring Data Center Bridging Features It is recommended that the sum of minimum bandwidth percentages configured on the CoS queues mapped to any TCG be less than or equal to that of the weight percentage configured for the TCG, so that packets are not dropped due to the congestion in the TCG. In example below, the TCG0 and TCG1 are allocated 30% and 70% of the bandwidth remaining after servicing TCG2 (strict priority) traffic. TCG2 traffic is handled with strict priority but can only consume up to 100% minus the sum of the minimum bandwidths of TCG0 and TCG1 (60%). console(config-if-Te1/0/1)#traffic-class-group weight 30 70 0 7. Set the Minimum Bandwidth for Each TCG (optional) In this step, the minimum bandwidth is configured for each TCG while in congestion. The minimum bandwidth setting ensures that a TCG is serviced during congestion even if a higher priority TCG has an offered load greater than 100% minus the minimum bandwidth assigned to the other TCGs. The minimum bandwidth is enforced on the egress TCG regardless of the scheduling mode and does not directly affect incoming traffic. The minimum bandwidth for a TCG is configured as a percentage of the total bandwidth, and the configured minimum bandwidths may sum to less than 100%. The sum may not exceed 100%. Minimum bandwidth may be configured on a single interface, a range of interfaces, or all interfaces. It is recommended that the minimum bandwidth for a TCG be configured to be less than or equal to the weight of the TCG. CAUTION: Sharing of bandwidth among TCGs is disabled if the sum of the minumum bandwidth settings equals 100%. console(config-if-Te1/0/1)#traffic-class-group min-bandwidth 10 50 0 8. Set the Maximum Bandwidth for each TCG (optional) In this step, the maximum bandwidth for each TCG is configured. The bandwidth allowed for the TCG will never exceed the maximum bandwidth configured, even if configured for strict priority. This limit is configured as a percentage of the total bandwidth and is used to shape egress traffic bursts to no greater than the configured value. The maximum bandwidth may be configured on a single interface, range of interfaces or all interfaces. When configured to be 0, unlimited bandwidth is allowed on the TCG. Configuring Data Center Bridging Features 1007 It is recommended that the maximum bandwidth be configured to be greater than the minimum bandwidth or the weight or be configured to 0 (unlimited burst size). console(config-if-Te1/0/1)#traffic-class-group max-bandwidth 50 90 20 9. Set the Scheduler Modes for the TCGs This step enables strict priority scheduling on TCGs. Strict priority scheduling on multiple TCGs prioritizes traffic from the highest numbered TCG for transmission first. Strict priority scheduling on a single TCG selects that TCG for transmission before the WDRR TCGs. Use the 'no' command to disable strict priority scheduling. It is recommended that all CoS queues enabled for strict priority scheduling be assigned to a single TCG other than TCG0. This scheme allows a larger number of priorities to be configured as strict priorities. console(config-if-Te1/0/1)#traffic-class-group strict 2 To show the weight, minimum bandwidth, maximum bandwidth, and scheduler modes of the TCGs, use the following command: console#show interfaces traffic-class-group tengigabitethernet 1/0/1 Interface...................................... Te1/0/1 Traffic Class Group -----------0 1 2 1008 Min. Bandwidth --------10 50 0 Max Bandwidth -----------50 90 20 Weight -----30 70 0 Configuring Data Center Bridging Features Scheduler Type -------------Weighted Round Robin Weighted Round Robin Strict ETS Theory of Operation First Level of Scheduling To understand the first level of scheduling, consider Table 29-1. Assume that we have eight ingress ports, each one receiving line rate traffic with one dot1p priority each. The table shows the mapping of dot1p priorities to the cosqueues, the min-bandwidth settings, and scheduler modes. Table 29-3. First Level of Scheduling Dot1p Priority CoS Queue CoS Minbandwidth Scheduler TCG Input to TCG 0 0 10 WRR 0 100% of pri0 1 1 10 WRR 1 10% each of 2 2 10 Strict 1 pri1, pri3 and 3 3 10 WRR 1 80% of pri2 4 4 15 WRR 2 25% each 5 5 15 WRR 2 of pri4, pri5 6 6 30 WRR 2 and 50% of 7 6 – – – pri6/pri7 In this scenario, the input to the TCGs is as follows: • All of the pri0 traffic reaches the TCG0. This is because there is no other priority contending for the same TCG. The minimum bandwidth setting on the CoS queue does not have any effect. • TCG1 would receive 10% each of pri1 and pri3 and 80% of pri2. Even though strict mode is enabled for pri2, the minimum bandwidth of pri1 and pri3 is first honored before applying strict mode on pri2. • TCG2 receives 25% each of pri4 and pri5 traffic and the other 50% can be of pri6 or pri7. This is based on the minimum bandwidth ratio, which is 15:15:30, converted to 1:1:2. Configuring Data Center Bridging Features 1009 Second Level of Scheduling To consolidate different traffic classes within different traffic types in a typical DCB environment, ETS provides an operational model for prioritization and bandwidth allocation for traffic. Figure 29-3 illustrates a typical example that consolidates three traffic types on a single 10GE link. For consolidation to be effective all traffic types must be serviced according to their requirements. For instance, SAN traffic must be guaranteed to be lossless, and the server cluster traffic (IPC) should be guaranteed a sufficiently high priority to meet the requirement of low latency. Figure 29-3. Converged Link on the DCB Environment In this example, to ensure that the server cluster traffic has low latency, it may be assigned to a TCG—say, TCG0—and a strict mode of scheduling is enabled on this group (weight set to 0%). SAN traffic can be assigned to TCG1 and LAN to TCG2. The TCG1 and TCG2 can be set to a weight of 50% each. With these configurations, Figure 29-3 illustrates how the load is managed at different times. When the offered load is 3 Gbps for each traffic type at time t1, the allocated bandwidth for TCG1 and TCG2 is 3.5 Gbps each. All traffic types, including IPC, SAN, and LAN, are allowed to be transmitted, since the offered load is under the allocated bandwidth. 1010 Configuring Data Center Bridging Features At time t2, a burst of LAN traffic is incoming at the rate of 4 Gbps, this burst is allowed to borrow the unused 0.5 Gbps bandwidth from SAN TCG and transmitted since the offered load of SAN is only 3 Gbps. At time t3, when the offered load of IPC falls to 2 Gbps and the bursty LAN traffic is at 6 Gbps, the available bandwidth for SAN and LAN is 4 Gbps each according to the TCG weights, which are set as 50% each. However, ETS allows the LAN traffic to borrow unused bandwidth from SAN traffic, and then 5 Gbps of LAN traffic is transmitted. Recommendations and Notes Lossless traffic must map user priorities one-to-one onto CoS queues. Lossless traffic must always be carried within a VLAN-tagged frame to differentiate it from untagged best-effort LAN control traffic, such as ARP and LLDP. Strict-priority CoS queues may starve other CoS queues of traffic if the offered load of the strict-priority CoS queues equals or exceeds the available capacity of the egress interfaces. It is recommended that either a CoS-queuelevel min-bandwidth setting be utilized to ensure a minimum amount of bandwidth is processed on the non-strict-priority queues if there is a possibility that the strict priority traffic is not limited in bandwidth by some other means. It is recommended that the sum of the minimum bandwidth percentages allocated to the group of CoS queues mapped to a single TCG be less than or equal to the weight percentage, so that packets are not dropped due to the congestion in the TCG. The maximum bandwidth for a TCG should always be configured to be greater than the minimum bandwidth or the weight of the TCG. In the case where all TCGs are configured as strict priority, inter-TCG scheduling is Weighted Deficit Round Robin, using the configured weights. Configuring CoS queues with a total maximum bandwidth that is less than the corresponding TCG weight will result in bandwidth being wasted in the secondary scheduler. Configuring CoS queues with a total minimum bandwidth that is greater than the corresponding TCG weight will flood the secondary scheduler and result in the minimum bandwidth parameter effectively overriding the TCG weight setting. Configuring Data Center Bridging Features 1011 Traffic is passed across stacking links using WDRR for all CoS queues. This will affect the observed behavior of ETS on egress ports scheduling traffic from over-subscribed stacking links. The three supported traffic class groups support an industry standard configuration such that one traffic class group offers lossless service (PFC enabled using WRR); one traffic class group contains priorities which are best effort (PFC disabled using WRR); and one traffic class group offers an expedited service (utilizes strict priority). When auto configuration is enabled on ports using ETS, the traffic classes are combined according to the above. Internally, the DCBX TCG mapping is restricted to using three TCGs regardless of the number of TCGs advertised by the configuration source, with the strict priority traffic mapped onto TCG 2, lossless traffic mapped onto TCG1, and all other traffic mapped onto TCG0. For ETS to be operational in a manually configured environment, the following minimum steps must be performed: 1 Configure the CoS queue to Traffic Class Group mapping for the egress ports. 2 Enable the appropriate scheduling algorithm for each TCG. 3 Configure the weight percentage for each TCG. Variation on the Example Configuration This example configures three classes of traffic and utilizes the secondary (ETS) scheduler only: • Best effort traffic: CoS Queue 0 for untagged and VLAN tagged frames with VPTs: 0, 1, and 2 • Lossless iSCSI: CoS Queue 1, VLAN tagged frames with VPT equal to 3 • Expedited Traffic: CoS Queue 2, VLAN tagged frames with VPTs: 4, 5, 6, 7 console(config-if-Te1/0/2)#classofservice console(config-if-Te1/0/2)#classofservice console(config-if-Te1/0/2)#classofservice console(config-if-Te1/0/2)#classofservice console(config-if-Te1/0/2)#classofservice console(config-if-Te1/0/2)#classofservice console(config-if-Te1/0/2)#classofservice console(config-if-Te1/0/2)#classofservice console(config-if-Te1/0/1)#classofservice console(config-if-Te1/0/1)#classofservice 1012 Configuring Data Center Bridging Features dot1p-mapping 0 0 dot1p-mapping 1 0 dot1p-mapping 2 0 dot1p-mapping 3 1 dot1p-mapping 4 2 dot1p-mapping 5 2 dot1p-mapping 6 2 dot1p-mapping 7 2 traffic-class-group 0 0 traffic-class-group 1 1 console(config-if-Te1/0/1)#classofservice traffic-class-group 2 2 console(config-if-Te1/0/1)#traffic-class-group weight 30 70 0 console(config-if-Te1/0/1)#traffic-class-group strict 2 N4000 Operation When DCBx is enabled on manually configured ports, it is not necessary for the ETS parameters to match, regardless of the version of DCBX negotiated or configured. Configuration mismatches are logged. In auto configuration mode, ETS parameters from the configuration source are checked (Max TCs 3 and bandwidth equal to 100%) and if the system is capable of performing the configuration, it is accepted and propagated as received to the other auto-configuration ports. The ETS Recommendation TLVs are preferred over the ETS Configuration TLVs. Auto-configuration via DCBX overrides manually configured ETS parameters for auto-configured ports, however, manual configuration is restored should the port be placed back into the manual port role. The ETS parameters received via DCBX are modified and applied to the system via the DCBX Mapping function as follows (references are to the 802.1Qaz parameters): • Like traffic classes are combined up to the limits of the system; e.g., no more than 2 lossless CoS queues may be configured. • The Priority Assignment Table (user priority to CoS queue mapping) is utilized by the system to map user priorities to the traffic classes (CoS queues). • The TSA Assignment Table is converted to use 3 TCGs internally. Priorities with like characteristics are combined into TCGs, i.e. strict priority traffic is combined into a TCG, lossless traffic is combined into a TCG, etc. Generally, strict priority traffic is mapped onto TCG 2, lossless traffic is mapped onto TCG1 and best effort traffic is mapped onto TCG0. • The bandwidths from the TC Bandwidth Table are summed based on the internal TCG mapping and are used to set the TCG weights. Other switches may assign bandwidth to strict priority queues. This bandwidth is counted in the sum to ETS 100% validation check, however, internally the weight for strict priority queues is ignored and they are configured for unlimited bandwidth. An implication of this assignment is that the percentage of bandwidth that may be consumed by a WDRR TCG after Configuring Data Center Bridging Features 1013 processing strict priority traffic is skewed to be the bandwidth of the individual TCG divided by the sum of the weights of all WDRR configured TCGs. The administrator may configure other parameters to work in conjunction with the received DCBX configuration, e.g. min-bandwidth per CoS queue and minimum or maximum bandwidth per TCG. 1014 Configuring Data Center Bridging Features 30 Managing the MAC Address Table This chapter describes the L2 MAC address table the switch uses to forward data between ports. The topics covered in this chapter include: • MAC Address Table Overview • Default MAC Address Table Values • Managing the MAC Address Table (Web) • Managing the MAC Address Table (CLI) MAC Address Table Overview The MAC address table keeps track of the MAC addresses that are associated with each port to allow the switch to forward unicast traffic through the appropriate port. This table is sometimes called the bridge table or the forwarding database. How Is the Address Table Populated? The MAC address table can contain two types of addresses: • Static: The address has been manually configured and does not age out. • Dynamic: The address has been automatically learned by the switch and can age out when it is not in use. Static addresses are configured by the administrator and added to the table. Dynamic addresses are learned by examining information in the Ethernet frame. When a frame arrives on a port, the switch looks at the frame header to learn the source MAC address of the frame, then adds the address, VLAN ID, and the ingress port to the MAC address table. The address table is constantly updated as new addresses are learned, and unused addresses age out. A frame that has a destination MAC address that matches an entry in the table is forwarded immediately to the associated port(s)/VLAN(s). Managing the MAC Address Table 1015 What Information Is in the MAC Address Table? Each entry in the address table, whether it is static or dynamic, includes the MAC address, the VLAN ID associated with the MAC address, and the interface on which the address was learned or configured. Each port can maintain multiple MAC addresses, and a MAC address can be associated with multiple VLANs. How Is the MAC Address Table Maintained Across a Stack? The MAC address table is synchronized across all stack members. When a member joins the stack, its previous MAC address table is overwritten by the table maintained by the stack. Default MAC Address Table Values Table 30-1 summarizes the default values for the MAC address table. Table 30-1. MAC Address Table Defaults Parameter Default Value Aging time 300 seconds Dynamic addresses Enabled (automatically learned) Static addresses None configured 1016 Managing the MAC Address Table Managing the MAC Address Table (Web) This section provides information about the OpenManage Switch Administrator pages to use to manage the MAC address table on a Dell Networking N2000, N3000, and N4000 series switches. For details about the fields on a page, click at the top of the page. Static Address Table Use the Static Address Table page to view MAC addresses that have been manually added to the MAC address table and to configure static MAC addresses. To display the Static Address Table page, click Switching → Address Tables → Static Address Table in the navigation panel. Figure 30-1. Static MAC Address Adding a Static MAC Address To add a static MAC address: 1 Open the Static MAC Address page. 2 Click Add. The Add Static MAC Address page displays. Managing the MAC Address Table 1017 Figure 30-2. Adding Static MAC Address 3 Select the interface to associate with the static address. 4 Specify the MAC address and an associated VLAN ID. 5 Click Apply. The new static address is added to the Static MAC Address Table, and the device is updated. 1018 Managing the MAC Address Table Global Address Table The Global Address Table page contains fields for querying information in the dynamic address table, including the interface type, MAC addresses, VLAN, and table sorting key. Packets forwarded to an address stored in the address table are forwarded directly to those ports. The Global Address Table also contains information about the aging time before a dynamic MAC address is removed from the table. To display the Global Address Table, click Switching → Address Tables → Global Address Table in the navigation panel. Figure 30-3. Global Address Table Managing the MAC Address Table 1019 Managing the MAC Address Table (CLI) This section provides information about the commands you use to manage the MAC address table on the switch. For more information about the commands, see the Dell Networking N2000, N3000, and N4000 Series Switches CLI Reference Guide at support.dell.com/manuals. Managing the MAC Address Table Beginning in Privileged EXEC mode, use the following commands to add a static MAC address to the table, control the aging time for dynamic addresses, and view entries in the MAC address table. Command Purpose configure Enter global configuration mode. mac address-table static Add a static MAC source address to the MAC address table. mac-address vlan vlan-id • mac-address — A valid MAC address in the format interface interface xxxx.xxxx.xxxx. • vlan-id —A valid VLAN. • interface — A valid port or LAG, including the interface type and number. mac address-table aging-time {0 | 101000000} Specify the number of seconds that must pass before an unused dynamically-learned MAC address is removed from the MAC address table. A value of 0 disables the aging time for the MAC address table. exit Exit to Privileged EXEC mode. show mac address-table View information about the entries in the MAC address [static | dynamic] table. Use the keywords static or dynamic to specify the address type to view. For dynamic entries, you can use the clear mac addresstable command to remove entries from the table. show mac address-table View information about the MAC addresses that have been configured or learned on the switch, a specific VLAN, or an {vlan vlan | interface interface [vlan vlan-id]} interface (Ethernet port or LAG/port-channel). show mac address-table View information about the number of addresses that have been configured or learned on the switch, a specific VLAN, count [{vlan vlan-id or an interface (Ethernet port or LAG/port-channel). |interface interface}] 1020 Managing the MAC Address Table 31 Configuring Routing Interfaces This chapter describes the routing (layer 3) interfaces the Dell Networking series switches support, which includes VLAN routing interfaces, loopback interfaces, and tunnel interfaces. The topics covered in this chapter are: • Routing Interface Overview • Default Routing Interface Values • Configuring Routing Interfaces (Web) • Configuring Routing Interfaces (CLI) For information about configuring IPv6 characteristics on routing interfaces, see "Configuring IPv6 Routing" on page 1241. For configuration examples that configure VLAN routing interfaces, see "IP Routing Configuration Example" on page 1084 in the Configuring IP Routing chapter. For a configuration example that includes tunnel and loopback interface creation, see "Interconnecting an IPv4 Backbone and Local IPv6 Network" on page 1187. Routing Interface Overview Routing interfaces are logical interfaces that can be configured with an IP address. Routing interfaces provide a means of transmitting IP packets between subnets on the network. What Are VLAN Routing Interfaces? VLANs divide a single physical network (broadcast domain) into separate logical networks. To forward traffic across VLAN boundaries, a layer 3 device, such as router, is required. Dell Networking series switches can act as layer 3 devices when you configure VLAN routing interfaces. VLAN routing interfaces make it possible to transmit traffic between VLANs while still containing broadcast traffic within VLAN boundaries. The configuration of VLAN routing interfaces makes inter-VLAN routing possible. Configuring Routing Interfaces 1021 For each VLAN routing interface you can assign a static IP address, or you can allow a network DHCP server to assign a dynamic IP address. When a port is enabled for bridging (L2 switching) rather than routing, which is the default, all normal bridge processing is performed for an inbound packet, which is then associated with a VLAN. Its MAC Destination Address (MAC DA) and VLAN ID are used to search the MAC address table. If routing is enabled for the VLAN, and the MAC DA of an inbound unicast packet is that of the internal router interface, the packet is routed. An inbound multicast packet is forwarded to all ports in the VLAN, plus the internal bridge-router interface, if it was received on a routed VLAN. Since a port can be configured to belong to more than one VLAN, VLAN routing might be enabled for all of the VLANs on the port or for only some of the VLANs on the port. VLAN Routing can be used to allow more than one physical port to reside on the same subnet. It could also be used when a VLAN spans multiple physical networks, or when additional segmentation or security is required. What Are Loopback Interfaces? A loopback interface is a logical interface that is always up and, because it cannot go down, allows the switch to have a stable IP address that other network devices and protocols can use to reach the switch. The loopback can provide the source address for sent packets. NOTE: In this context, loopback interfaces should not be confused with the loopback IP address, usually 127.0.0.1, assigned to a host for handling self-routed packets. The loopback interface does not behave like a network switching port. Specifically, there are no neighbors on a loopback interface; it is a pseudodevice for assigning local addresses so that the other layer 3 devices can communicate with the switch by using the loopback IP address. The loopback interface is always up and can receive traffic from any of the existing active interfaces. Thus, given reachability from a remote client, the address of the loopback can be used to communicate with the switch through various services such as Telnet and SSH. In this way, the IP address on a loopback behaves identically to any of the local addresses of the VLAN routing interfaces in terms of the processing of incoming packets. 1022 Configuring Routing Interfaces What Are Tunnel Interfaces? Tunnels are a mechanism for transporting a packet across a network so that it can be evaluated at a remote location or tunnel endpoint. The tunnel, effectively, hides the packet from the network used to transport the packet to the endpoint. This allows for the transmission of packets that the transport network cannot process directly, such as in one of the following cases: • The packet protocol is not supported. • The packet is in an incompatible addressing space. • The packet is encrypted. Dell Networking series switches support tunnels to encapsulate IPv6 traffic in IPv4 tunnels to provide functionality to facilitate the transition of IPv4 networks to IPv6 networks. The switch supports two types of tunnels: configured (6-in-4) and automatic (6-to-4). Configured tunnels have an explicit configured endpoint and are considered to be point-to-point interfaces. Automatic tunnels determine the endpoint of the tunnel from the destination address of packets routed into the tunnel. These tunnels correspond to Non-Broadcast Multi-Access (NBMA) interfaces. A configured tunnel interface has a single tunnel associated with it, while an automatic tunnel interface has an infinite number of tunnels (limited only by the address encoding scheme). Because tunnels are used as logical interfaces, you can define static routes that reference the tunnels. Additionally, dynamic routing can be configured to use the tunnels. Configuring Routing Interfaces 1023 Why Are Routing Interfaces Needed? The routing interfaces this chapter describes have very different applications and uses, as this section describes. If you use the switch as a layer 2 device that handles switching only, routing interface configuration is not required. When the switch is used as a layer 2 device, it typically connects to an external layer 3 device that handles the routing functions. VLAN Routing VLAN routing is required when the switch is used as a layer 3 device. VLAN routing must be configured to allow the switch to forward IP traffic between subnets and allow hosts in different networks to communicate. In Figure 31-1 the Dell Networking switch is configured as an L3 device and performs the routing functions for hosts connected to the L2 switches. For Host A to communicate with Host B, no routing is necessary. These hosts are in the same VLAN. However, for Host A in VLAN 10 to communicate with Host C in VLAN 20, the Dell Networking switch must perform inter-VLAN routing. Figure 31-1. Inter-VLAN Routing 1024 Configuring Routing Interfaces Loopback Interfaces When packets are sent to the loopback IP address, the network should be able to deliver the packets as long as any physical interface on the switch is up. There are many cases where you need to send traffic to a switch, such as in switch management. The loopback interface IP address is a good choice for communicating with the switch in these cases because the loopback interface cannot go down when the switch is powered on and operational. Tunnel Interface Tunnels can be used in networks that support both IPv6 and IPv4. The tunnel allows non-contiguous IPv6 networks to be connected over an IPv4 infrastructure. Configuring Routing Interfaces 1025 Default Routing Interface Values By default, no routing interfaces are configured. When you create a VLAN, no IP address is configured, and DHCP is disabled. After you configure an IP address on a VLAN or loopback interface, the VLAN interface is available for L3 routing (if enabled) and is capable of resolved ARPs and responding to pings, and the interface has the default configuration shown in Table 31-1. Most interface configuration parameters are not applicable to loopback interfaces, so you cannot change the default values. However, when you create a loopback interface, the default values are similar to those of VLAN routing interfaces, as Table 31-1 shows. Table 31-1. VLAN Routing Interface and Loopback Interface Defaults Parameter Default Value Forward Net Directed Broadcasts Disabled Encapsulation Type Ethernet (N/A for loopbacks) Proxy Arp Enabled Local Proxy Arp Disabled IP MTU 1500 Bandwidth Not configured. Destination Unreachables Enabled ICMP Redirects Enabled When you create a tunnel, it has the default values shown in Table 31-2 Table 31-2. Tunnel Interface Defaults Parameter Default Value Tunnel mode 6-in-4 configured Link Local Only Mode Disabled Source address None Destination address 0.0.0.0 1026 Configuring Routing Interfaces Configuring Routing Interfaces (Web) This section provides information about the OpenManage Switch Administrator pages for configuring and monitoring VLAN routing interfaces, loopback interfaces, and tunnels on a Dell Networking N2000, N3000, and N4000 series switches. For details about the fields on a page, click at the top of the page. IP Interface Configuration Use the IP Interface Configuration page to update IP interface data for this switch. The IP interface configuration includes the ability to configure the bandwidth, Destination Unreachable messages, and ICMP Redirect messages. To display the page, click Routing → IP → IP Interface Configuration in the navigation panel. Figure 31-2. IP Interface Configuration Configuring Routing Interfaces 1027 DHCP Lease Parameters Use the DHCP Lease Parameters page to view information about the network information automatically assigned to an interface by the DHCP server. To display the page, click Routing → IP → DHCP Lease Parameters in the navigation panel. Figure 31-3. DHCP Lease Parameters VLAN Routing Summary Use the VLAN Routing Summary page to view summary information about VLAN routing interfaces configured on the switch. To display the page, click Routing → VLAN Routing → Summary in the navigation panel. 1028 Configuring Routing Interfaces Figure 31-4. VLAN Routing Summary Tunnel Configuration Use the Tunnels Configuration page to create, configure, or delete a tunnel. To display the page, click Routing → Tunnels → Configuration in the navigation panel. Figure 31-5. Tunnel Configuration Configuring Routing Interfaces 1029 Tunnels Summary Use the Tunnels Summary page to display a summary of configured tunnels. To display the page, click Routing → Tunnels → Summary in the navigation panel. Figure 31-6. Tunnels Summary 1030 Configuring Routing Interfaces Loopbacks Configuration Use the Loopbacks Configuration page to create, configure, or remove loopback interfaces. You can also set up or delete a secondary address for a loopback. To display the page, click Routing → Loopback Interfaces → Loopback Interfaces Configuration in the navigation panel. Figure 31-7. Loopback Configuration Configuring Routing Interfaces 1031 Loopbacks Summary Use the Loopbacks Summary page to display a summary of configured loopback interfaces on the switch. To display the page, click Routing → Loopback Interfaces → Loopback Interfaces Summary in the navigation panel. Figure 31-8. Loopbacks Summary 1032 Configuring Routing Interfaces Configuring Routing Interfaces (CLI) This section provides information about the commands you use to configure VLAN routing interfaces, loopbacks, and tunnels on the switch. For more information about the commands, see the Dell Networking N2000, N3000, and N4000 Series Switches CLI Reference Guide at support.dell.com/manuals. Configuring VLAN Routing Interfaces (IPv4) Beginning in Privileged EXEC mode, use the following commands to configure a VLAN as a routing interface and set the IP configuration parameters. Command Purpose configure Enter Global Configuration mode. interface vlan vlan-id Enter Interface Configuration mode for the specified VLAN. ip address {dhcp | none |ip_address subnet_mask [secondary]} Configure the IP address. Use the dhcp keyword to enable the DHCP client and obtain an IP address from a network DHCP server. Use none to release the address obtained from the DHCP server. Use ip_address and subnet_mask to assign a static IP address. If you configure a static address, you can use the secondary keyword to specify that the address is a secondary IP address. ip netdirbcast Enable the forwarding of network-directed broadcasts. encapsulation {ethernet | Configure the link-layer encapsulation type for the snap} packet. Routed frames are always ethernet encapsulated when a frame is routed to a VLAN. ip proxy-arp Enable proxy ARP on the interface. Without proxy ARP, the switch responds to an ARP request only if the target IP address is an address configured on the interface where the ARP request arrived. This command is not available in interface range mode. Configuring Routing Interfaces 1033 Command Purpose ip local-proxy-arp Enable local proxy ARP on the interface to allow the switch to respond to ARP requests for hosts on the same subnet as the ARP source. bandwidth size Set the configured bandwidth on this interface to communicate the speed of the interface to higher level protocols. OSPF uses the bandwidth value to compute link cost. The range is 1–10000000. ip unreachables Allow the switch to send ICMP Destination Unreachable messages in response to packets received on the interface. ip redirects Allow the switch to send ICMP Redirect messages in response to packets received on the interface. exit Exit to Global Config mode. ip_address ip default-gateway Configure the default gateway. All switch interfaces use the same default gateway. exit Exit to Privileged EXEC mode. show dhcp lease [interface View information about the DHCP leases acquired for all interfaces or for the specified interface. interface] For a VLAN, the interface_string parameter is vlan followed by the VLAN ID, with no space, for example vlan10. show ip interface vlan vlan- View the IP interface configuration information for the specified routing VLAN. id 1034 Configuring Routing Interfaces Configuring Loopback Interfaces Beginning in Privileged EXEC mode, use the following commands to configure a loopback interface. Command Purpose configure Enter Global Configuration mode. interface loopback Create the loopback interface and enter Interface Configuration mode for the specified loopback interface. ip address ip_address subnet_mask [secondary] Configure a static IP address and subnet mask. Use the secondary keyword to specify that the address is a secondary IP address. CTRL + Z Exit to Privileged EXEC mode. loopback-id show ip interface loopback View interface configuration information for the specified loopback interface. loopback-id Configuring Routing Interfaces 1035 Configuring Tunnels Beginning in Privileged EXEC mode, use the following commands to configure a loopback interface. NOTE: For information about configuring the IPv6 interface characteristics for a tunnel, see "Configuring IPv6 Routing" on page 1241. Command Purpose configure Enter Global Configuration mode. interface tunnel tunnel-id Create the tunnel interface and enter Interface Configuration mode for the specified tunnel. tunnel mode ipv6ip [6to4] Specify the mode of the tunnel. If you use the 6to4 keyword, the tunnel is an automatic tunnel. If you omit the keyword, the tunnel is a point-to-point (configured) tunnel. ipv6 enable Enable IPv6 on this interface using the Link Local address. tunnel source {ipv4addr | vlan vlan-id} Specify the source transport address of the tunnel, either, which can be an IPv4 address or a VLAN routing interface. ipv4addr tunnel destination Specify the destination transport IPv4 address of the tunnel. CTRL + Z Exit to Privileged EXEC mode. show interfaces tunnel [tunnel-id] View configuration information for all tunnels or for the specified tunnel. 1036 Configuring Routing Interfaces 32 Configuring DHCP Server and Relay Settings This chapter describes how to configure the switch to dynamically assign network information to hosts by using the Dynamic Host Configuration Protocol (DHCP). The topics covered in this chapter include: • DHCP Overview • Default DHCP Server Values • Configuring the DHCP Server (Web) • Configuring the DHCP Server (CLI) • DHCP Server Configuration Examples DHCP Overview DHCP is generally used between clients and servers for the purpose of assigning IP addresses, gateways, and other network settings such as DNS and SNTP server information. DHCP Snooping is a security feature that monitors DHCP messages between a DHCP client and DHCP server. It filters harmful DHCP messages and builds a bindings database of (MAC address, IP address, VLAN ID, port) tuples that are specified as authorized. DHCP snooping can be enabled globally and on specific VLANs. For information about DHCP Snooping, see "Snooping and Inspecting Traffic" on page 879. Dell Networking switches support a DHCP client for obtaining the switch address from the network, an IPv4 DHCP server for serving IPv4 addresses to DHCP clients in the network, L2 and L3 DHCP relay for relaying IPv4 address assignments from network-based DHCP servers to clients in the same or different subnets, and DHCP snooping for protecting the switch and DHCP clients from certain security risks. Configuring DHCP Server and Relay Settings 1037 How Does DHCP Work? When a host connects to the network, the host’s DHCP client broadcasts a message requesting information from any DHCP server that receives the broadcast. One or more DHCP servers respond to the request. The response includes the requested information, such as the IP address, subnet mask, and default gateway IP address. The client accepts an offer from one of the servers, and the server sends an acknowledgment to the client to confirm the transaction. Figure 32-1. Message Exchange Between DHCP Client and Server DH C PD ISC O V ER (broadcast) DH C PO FFE R (unicast) ` DH C PR EQ U ES T (broadcast) D HC PA CK (unicast) DHCP Client DHCP Server (Dell Networking Switch) The DHCP server maintains one or more set of IP addresses the and other configuration information available, by request, to DHCP clients. Each set of information is known as an address pool. After a client leases an IP address from the DHCP server, the server adds an entry to its database. The entry is called a binding. What are DHCP Options? DHCP options are collections of data with type codes that indicate how the options should be used. Options can specify information that is required for the DHCP protocol, IP stack configuration parameters for the client, information allowing the client to rendezvous with DHCP servers, and so on. When a client broadcasts a request for information, the request includes the option codes that correspond to the information the client wants the DHCP server to supply. The Web pages and CLI commands to configure DHCP server settings include many predefined options for the information that is most commonly requested by DHCP clients. For example, DHCP client 1038 Configuring DHCP Server and Relay Settings discover requests typically include options for the IP address (option 50), subnet mask (option 1), default gateway (option 3), and DNS server (option 6). These options are predefined. For options that are not predefined, you can enter the option code and specify the data type along with the data that the switch should include in DHCP offers. RFC2132 specifies many of the DHCP options. Additional options are described in later RFCs. How is DHCP Option 82 Used? The Dell Networking Operating System (DNOS) supports insertion of DHCP Option 82 information into DHCP messages relayed to DHCP servers. The Dell Networking switch can be configured to insert either the Circuit ID or the Remote ID or both. When enabled, the Circuit ID contains the port identifier over which the DHCP request was received. The Remote ID is configurable by the administrator on a per-switch basis. Consider a network with multiple DHCP servers, where the administrator wishes to serve addresses from a specific server based on the switch and port to which the user station is connected. User traffic is served on VLAN 10 or 20. The administrator globally enables DHCP relay and configures DHCP relay on the end-user ports of each switch as follows: console(config)#dhcp l2relay console(config)#interface range gi1/0/1-24 console(config-if)#dhcp l2relay console(config-if)#exit Then, the administrator configures the remote-id and circuit-id: console(config)#dhcp l2relay circuit-id vlan 10,20 console(config)# dhcp l2relay remote-id "Switch A" vlan 10,20 Finally, the administrator configures the uplink for DHCP relay and sets the interface to trust Option 82 information received on the interface: console(config)#dhcp l2relay console(config)#interface range te1/0/1 console(config-if)#dhcp l2relay console(config-if)#dhcp l2relay trust console(config-if)#exit Configuring DHCP Server and Relay Settings 1039 The administrator is using a Microsoft DHCP server. Microsoft DHCP servers do not have native support for DHCP Option 82, but it can be added using the DhcpServerCalloutEntry API to retrieve the information via the DhcpHandleOptionsHook configured on the switches. Adding Option 82 support enables choosing whether or not a particular DHCP server should respond to the DHCP request, and whether it should only respond to requests from a particular switch (as identified by the remote-id) and port (as identified by the circuit-id). For further information and an example, follow this web link: http://blogs.technet.com/b/teamdhcp/archive/2009/07/06/dhcp-server-calloutapi-usage.aspx For Linux-based systems, which natively support option 82, a configuration to serve two private pools (Pool1 and Pool2) and one public pool of DHCP addresses based upon the remote-id and circuit-id might look like the following: dhcpd.conf file: class "Pool1" { match option agent.remote-id; match option agent.circuit-id; } subclass "Pool1" "Switch A" "Gi1/0/1"; subclass "Pool1" "Switch A" "Gi1/0/2"; subclass "Pool1" "Switch A" "Gi1/0/3"; class "Pool2" { match option agent.remote-id; match option agent.circuit-id; } subclass "Pool2" "Switch B" "Gi1/0/1"; subclass "Pool2" "Switch B" "Gi1/0/2"; subclass "Pool2" "Switch B" "Gi1/0/3"; shared-network Public { subnet 10.1.222.0 netmask 255.255.254.0 { pool { deny members of "Pool1"; deny members of "Pool2"; option routers 10.1.222.1; 1040 Configuring DHCP Server and Relay Settings option subnet-mask 255.255.254.0; option domain-name-servers 10.1.218.3, 10.1.219.3; range dynamic-bootp 10.1.222.3 10.1.222.254; range dynamic-bootp 10.1.223.3 10.1.223.254; default-lease-time 21600; max-lease-time 43200; } } subnet 10.2.109.192 netmask 255.255.255.224 { pool { allow members of "Pool1"; range 10.2.109.194 10.2.109.222; option routers 10.2.109.193; option subnet-mask 255.255.255.224; option domain-name-servers 10.1.218.3,10.1.219.3; default-lease-time 21600; max-lease-time 43200; } } subnet 10.2.109.224 netmask 255.255.255.224 { pool { allow members of "Pool2"; range 10.2.109.226 10.2.109.254; option routers 10.2.109.225; option subnet-mask 255.255.255.224; option domain-name-servers 10.1.218.3,10.1.219.3; default-lease-time 21600; max-lease-time 43200; } } } } What Additional DHCP Features Does the Switch Support? The switch software includes a DHCP client that can request network information from a DHCP server on the network during the initial system configuration process. For information about enabling the DHCP client, see "Setting the IP Address and Other Basic Network Information" on page 147. If the switch is functioning as a Layer 3 device, the Layer 3 DHCP Relay Agent can relay DHCP messages between DHCP clients and DHCP servers that are located in different IP subnets. Configuring DHCP Server and Relay Settings 1041 The DHCP Layer 2 Relay feature permits Layer 3 Relay agent functionality in Layer 2 switched networks. The switch supports L2 DHCP relay configuration on individual ports, link aggregation groups (LAGs) and VLANs. For information about Layer 2 and Layer 3 DHCP Relay, see "Configuring L2 and L3 Relay Features" on page 1087. Default DHCP Server Values By default, the DHCP server is disabled, and no address pools are configured. You must create at least one address pool and enable the DHCP server to allow the switch to dynamically assign network information to hosts with DHCP clients that broadcast requests. The DHCP server can lease a maximum of 256 addresses. 1042 Configuring DHCP Server and Relay Settings Configuring the DHCP Server (Web) This section provides information about the OpenManage Switch Administrator pages for configuring and monitoring the DHCP server on a Dell Networking N2000, N3000, and N4000 series switches. For details about the fields on a page, click at the top of the page. DHCP Server Network Properties Use the Network Properties page to define global DHCP server settings and to configure addresses that are not included in any address pools. To display the Network Properties page, click Routing → IP → DHCP Server → Network Properties in the navigation panel. Figure 32-2. DHCP Server Network Properties Configuring DHCP Server and Relay Settings 1043 Adding Excluded Addresses To exclude an address: 1 Open the Network Properties page. 2 Click Add Excluded Addresses to display the Add Excluded Addresses page. 3 In the From field, enter the first IP address to exclude from any configured address pool. 4 If the address in the From field is the only address to exclude, or if the excluded addresses are non-contiguous, leave the To field as the default value of 0.0.0.0. Otherwise, enter the last IP address to excluded from a contiguous range of IP addresses. In Figure 32-3, the From field contains the IP address 192.168.2.1, and the To field contains the IP address 192.168.2.5. This means that the following IP addresses are not available for lease: • 192.168.2.1 • 192.168.2.2 • 192.168.2.3 • 192.168.2.4 • 192.168.2.5 Figure 32-3. Add Excluded Addresses 5 Click Apply. 1044 Configuring DHCP Server and Relay Settings Deleting Excluded Addresses To remove an excluded address: 1 Open the Network Properties page. 2 Click Delete Excluded Addresses to display the Delete Excluded Addresses page. 3 Select the check box next to the address or address range to delete. Figure 32-4. Delete Excluded Addresses 4 Click Apply. Address Pool Use the Address Pool page to create the pools of IP addresses and other network information that can be assigned by the server. To display the Address Pool page, click Routing → IP → DHCP Server → Address Pool in the navigation panel. Configuring DHCP Server and Relay Settings 1045 Figure 32-5. Address Pool Adding a Network Pool To create and configure a network pool: 1 Open the Address Pool page. 2 Click Add Network Pool to display the Add Network Pool page. 3 Assign a name to the pool and complete the desired fields. In Figure 32-6, the network pool name is Engineering, and the address pool contains all IP addresses in the 192.168.5.0 subnet, which means a client that receives an address from the DHCP server might lease an address in the range of 192.168.5.1 to 192.168.5.254. 1046 Configuring DHCP Server and Relay Settings Figure 32-6. Add Network Pool The Engineering pool also configures clients to use 192.168.5.1 as the default gateway IP address and 192.168.1.5 and 192.168.2.5 as the primary and secondary DNS servers. NOTE: The IP address 192.168.5.1 should be added to the global list of excluded addresses so that it is not leased to a client. 4 Click Apply. Adding a Static Pool To create and configure a static pool of IP addresses: 1 Open the Address Pool page. 2 Click Add Static Pool to display the Add Static Pool page. 3 Assign a name to the pool and complete the desired fields. Configuring DHCP Server and Relay Settings 1047 In Figure 32-7, the Static pool name is Lab, and the name of the client in the pool is LabHost1. The client’s MAC address is mapped to the IP address 192.168.11.54, the default gateway is 192.168.11.1, and the DNS servers the client will use have IP addresses of 192.168.5.100 and 192.168.2.5. Figure 32-7. Add Static Pool 4 Click Apply. 1048 Configuring DHCP Server and Relay Settings Address Pool Options Use the Address Pool Options page to view manually configured options. You can define options when you create an address pool, or you can add options to an existing address pool. To display the Address Pool Options page, click Routing → IP → DHCP Server → Address Pool Options in the navigation panel. Figure 32-8. Address Pool Options Defining DHCP Options To configure DHCP options: 1 Open the Address Pool page. 2 Select the Add Options check box. 3 Select the check box that corresponds to the value type (ASCII, Hexadecimal, or IP address). 4 Specify the value(s) in the corresponding field. Figure 32-9 shows an example of adding the SMTP server IP address. The option code for the SMTP server is 69, and the IP address of the SMTP server is 192.168.10.15. Configuring DHCP Server and Relay Settings 1049 Figure 32-9. Add DHCP Option 5 Click Apply. 6 To verify that the option has been added to the address pool, open the Address Pool Options page. 1050 Configuring DHCP Server and Relay Settings Figure 32-10. View Address Pool Options DHCP Bindings Use the DHCP Bindings page to view information about the clients that have leased IP addresses from the DHCP server. To display the DHCP Bindings page, click Routing → IP → DHCP Server → DHCP Bindings in the navigation panel. Figure 32-11. DHCP Bindings Configuring DHCP Server and Relay Settings 1051 DHCP Server Reset Configuration Use the Reset Configuration page to clear the client bindings for one or more clients. You can also reset bindings for clients that have leased an IP address that is already in use on the network. To display the Reset Configuration page, click Routing → IP → DHCP Server → Reset Configuration in the navigation panel. Figure 32-12. Reset DHCP Bindings DHCP Server Conflicts Information Use the Conflicts Information page to view information about clients that have leased an IP address that is already in use on the network. To display the Conflicts Information page, click Routing → IP → DHCP Server → Conflicts Information in the navigation panel. Figure 32-13. 1052 DHCP Server Conflicts Information Configuring DHCP Server and Relay Settings DHCP Server Statistics Use the Server Statistics page to view general DHCP server statistics, messages received from DHCP clients, and messages sent to DHCP clients. To display the Server Statistics page, click Routing → IP → DHCP Server → Server Statistics in the navigation panel. Figure 32-14. DHCP Server Statistics Configuring DHCP Server and Relay Settings 1053 Configuring the DHCP Server (CLI) This section provides information about the commands you use to configure and monitor the DHCP server and address pools. For more information about the commands, see the Dell Networking N2000, N3000, and N4000 Series Switches CLI Reference Guide at support.dell.com/manuals. Configuring Global DHCP Server Settings Beginning in Privileged EXEC mode, use the following commands to configure settings for the DHCP server. Command Purpose configure Enter Global Configuration mode. service dhcp Enable the DHCP server. ip dhcp ping packets Specify the number, in a range from 2-10, of packets a DHCP server sends to a pool address as part of a ping operation. ip dhcp conflict logging Enable conflict logging on DHCP server ip dhcp bootp automatic Enable the allocation of the addresses to the BootP client. ip dhcp excludedaddress lowaddress [highaddress] Specify the IP addresses that a DHCP server should not assign to DHCP clients. You can specify a single IP address, or you can specify a contiguous range by using both the low-address and high-address variables. exit Exit to Privileged EXEC mode. show ip dhcp global configuration Verify the global DHCP server configuration. 1054 Configuring DHCP Server and Relay Settings Configuring a Dynamic Address Pool Beginning in Privileged EXEC mode, use the following commands to create an address pool with network information that is dynamically assigned to hosts with DHCP clients that request the information. Command Purpose configure Enter Global Configuration mode. ip dhcp pool name Create a DHCP address pool and enters DHCP pool configuration mode. network network-ip [mask | prefixlength] Configure the subnet number and mask for a DHCP address pool. Clients requesting an IP address can be assigned any non-excluded IP address within this network. lease [duration] | infinite}] Specify the duration of the lease for an IP address that is assigned from a DHCP server to a DHCP client. • duration— Days the lease is valid. You can optionally specify the hours and minutes after specifying the days. • infinite — 60 day lease default-router address1 [address2....address8] Specify the list of default gateway IP addresses to be assigned to the DHCP client. dns-server address1 [address2....address8] Specify the list of DNS server IP addresses to be assigned to the DHCP client. domain-name domain Specify the domain name for a DHCP client. option code {ascii string Manually configure DHCP options. | hex string1 [string2...string8] | ip address1 [address2...address8]} CTRL + Z Exit to Privileged EXEC mode. show ip dhcp pool configuration {name | all} View the settings for the specified address pool or for all configured address pools. Configuring DHCP Server and Relay Settings 1055 Configuring a Static Address Pool Beginning in Privileged EXEC mode, use the following commands to create a static address pool and specify the network information for the pool. The network information configured in the static address pool is assigned only to the host with the hardware address or client identifier that matches the information configured in the static pool. Command Purpose configure Enter Global Configuration mode. ip dhcp pool name Create a DHCP address pool and enters DHCP pool configuration mode. client-name name Specify the DHCP client name. hardware-address mac [type] Specify the hardware address of the client in the static pool. • mac—MAC address of the hardware platform of the client consisting of 6 bytes in dotted hexadecimal format. • type — Indicates the protocol of the hardware platform. It is 1 for Ethernet and 6 for IEEE 802. client-identifier uniqueidentifier Specify the unique identifier for a DHCP client. The unique-identifier is a valid notation in hexadecimal format. In some systems, such as Microsoft DHCP clients, the client identifier is required instead of hardware addresses. The unique-identifier is a concatenation of the media type and the MAC address. For example, the Microsoft client identifier for Ethernet address c819.2488.f177 is 01c8.1924.88f1.77 where 01 represents the Ethernet media type. host address [mask | prefix-length] Specify the IP address and (optionally) network mask for a manual binding to a DHCP client. lease [duration] | infinite}] Specify the duration of the lease for an IP address that is assigned from a DHCP server to a DHCP client. • duration— Days the lease is valid. You can optionally specify the hours and minutes after specifying the days. • infinite — 60 day lease 1056 Configuring DHCP Server and Relay Settings Command Purpose default-router address1 [address2....address8] Specify the list of default gateway IP addresses to be assigned to the DHCP client. dns-server address1 [address2....address8] Specify the list of DNS server IP addresses to be assigned to the DHCP client. domain-name domain Specify the domain name for a DHCP client. option code {ascii string Manually configure DHCP options. | hex string1 [string2...string8] | ip address1 [address2...address8]} CTRL + Z Exit to Privileged EXEC mode. show ip dhcp pool configuration {name | all} View the settings for the specified address pool or for all configured address pools. Monitoring DHCP Server Information Beginning in Privileged EXEC mode, use the following commands to view bindings, conflicts, and statistics, and to clear the information. Command Purpose show ip dhcp binding [address] View the current binding information in the DHCP server database. Specify the IP address to view a specific binding. clear ip dhcp binding {address | *} Delete an automatic address binding from the DHCP server database. Use * to clear all bindings. show ip dhcp conflict [address] View the current binding conflicts in the DHCP server database. Specify the IP address to view a specific conflict. clear ip dhcp conflict {address | *} Clear an address conflict from the DHCP Server database. Use * to clear all conflicts. show ip dhcp server statistics View DHCP server statistics. clear ip dhcp server statistics Reset all DHCP server statistics to zero. Configuring DHCP Server and Relay Settings 1057 DHCP Server Configuration Examples This section contains the following examples: • Configuring a Dynamic Address Pool • Configuring a Static Address Pool Configuring a Dynamic Address Pool The commands in this example create an address pool that dynamically assigns network information to hosts with DHCP clients that broadcast DHCP messages. The hosts are assigned an IP address from the 192.168.5.0 network. The IP addresses 192.168.5.1–192.168.5.20, and 192.168.5.100 are excluded from the address pool. To configure the switch: 1 Enable the DHCP service and create an address pool named “Engineering”, and then enter into DHCP pool configuration mode for the pool. console#configure console(config)#service dhcp console(config)#ip dhcp pool Engineering 2 Specify the IP addresses that are available in the pool. console(config-dhcp-pool)#network 192.168.5.0 255.255.255.0 3 Specify the IP address to use as the default gateway. console(config-dhcp-pool)#default-router 192.168.5.1 4 Specify the primary and secondary DNS servers the hosts will use. console(config-dhcp-pool)#dns-server 192.168.5.10 console(config-dhcp-pool)#dns-server 192.168.5.11 5 Specify the domain name to be assigned to clients that lease an address from this pool. console(config-dhcp-pool)#domain-name engineering.dell.com console(config-dhcp-pool)#exit 1058 Configuring DHCP Server and Relay Settings 6 In Global Configuration mode, add the addresses to exclude from the pool. Clients will not be assigned these IP addresses. console(config)#ip dhcp excluded-address 192.168.5.1 192.168.5.20 console(config)#ip dhcp excluded-address 192.168.5.100 7 Enable the DHCP server on the switch. console(config)#service dhcp console(config)#exit 8 View DHCP server settings. console#show ip dhcp global configuration Service DHCP...................Enable Number of Ping Packets.........2 Excluded Address...............192.168.2.1 to 192.168.2.20 1.2.2.2 to 1.5.5.5 192.168.5.1 to 192.168.5.20 192.168.5.100 to 192.168.5.100 Conflict Logging...............Enable Bootp Automatic................Disable 9 View information about all configured address pools. console#show ip dhcp pool configuration all Pool: Engineering Pool Type.......................... Network............................ Lease Time......................... DNS Servers........................ Default Routers.................... Domain Name........................ Network 192.168.5.0 255.255.255.0 1 days 0 hrs 0 mins 192.168.5.11 192.168.5.1 engineering.dell.com Configuring DHCP Server and Relay Settings 1059 Configuring a Static Address Pool The commands in this example create an address pool that assigns the address 192.168.2.10 to the host with a MAC address of 00:1C:23:55:E9:F3. When this hosts sends a DHCP message requesting network information, the switch will offer the information configured in this example, which includes a custom DHCP option to assign the SMTP server IP address. To configure the switch: 1 Enable the DHCP service and create an address pool named “Tyler PC”, and then enter into DHCP pool configuration mode for the pool. console#configure console(config)#serive dhcp console(config)#ip dhcp pool "Tyler PC" 2 Specify the IP addresses that are available in the pool. console(config-dhcp-pool)#hardware-address 00:1C:23:55:E9:F3 3 Specify the IP address and subnet mask to assign to the client. console(config-dhcp-pool)#host 192.168.2.10 255.255.255.0 4 Specify the IP address to use as the default gateway. console(config-dhcp-pool)#default-router 192.168.2.1 5 Specify the primary and secondary DNS servers the hosts will use. console(config-dhcp-pool)#dns-server 192.168.2.100 console(config-dhcp-pool)#dns-server 192.168.5.101 6 Specify the domain name to be assigned to clients that lease an address from this pool. console(config-dhcp-pool)#domain-name executive.dell.com 7 Specify the option that configures the SMTP server IP address to the host. console(config-dhcp-pool)#option 69 ip 192.168.1.33 1060 Configuring DHCP Server and Relay Settings console(config-dhcp-pool)#exit 8 View information about the static address pool. console#show ip dhcp pool configuration "Tyler PC" Pool: Tyler PC Pool Type..........................Static Client Name........................TylerPC Hardware Address.................. 00:1c:23:55:e9:f3 Hardware Address Type..............ethernet Host.............................. 192.168.2.10 255.255.255.0 Lease Time........................ 1 days 0 hrs 0 mins DNS Servers....................... 192.168.2.101 Default Routers................... 192.168.2.1 Domain Name....................... executive.dell.com Option............................ 69 ip 192.168.1.33 Configuring DHCP Server and Relay Settings 1061 1062 Configuring DHCP Server and Relay Settings Configuring IP Routing 33 This chapter describes how to configure routing on the switch, including global routing settings, Address Resolution Protocol (ARP), router discovery, and static routes. The topics covered in this chapter include: • IP Routing Overview • Default IP Routing Values • Configuring IP Routing Features (Web) • Configuring IP Routing Features (CLI) • IP Routing Configuration Example IP Routing Overview The Dell Networking series switches are multilayer switches that support static and dynamic routing. Table 33-1 describes some of the general routing features that you can configure on the switch. Table 33-1. IP Routing Features Feature Description ICMP message control You can configure the type of ICMP messages that the switch responds to as well as the rate limit and burst size. Default gateway The switch supports a single default gateway. A manually configured default gateway is more preferable than a default gateway learned from a DHCP server. ARP table The switch maintains an ARP table that maps an IP address to a MAC address. You can create static ARP entries in the table and manage various ARP table settings such as the aging time of dynamically-learned entries. Configuring IP Routing 1063 Table 33-1. IP Routing Features (Continued) Feature Description ICMP Router Discovery Protocol (IRDP) Hosts can use IRDP to identify operational routers on the subnet. Routers periodically advertise their IP addresses. Hosts listen for these advertisements and discover the IP addresses of neighboring routers. Routing table entries You can configure the following route types in the routing table: • Default: The default route is the route the switch will use to send a packet if the routing table does not contain a longer matching prefix for the packet's destination. • Static: A static route is a route that you manually add to the routing table. • Static Reject: Packets that match a reject route are discarded instead of forwarded. The router may send an ICMP Destination Unreachable message. Route preferences 1064 Configuring IP Routing The common routing table collects static, local, and dynamic (routing protocol) routes. When there is more than one route to the same destination prefix, the routing table selects the route with the best (lowest) route preference. Default IP Routing Values Table 33-2 shows the default values for the IP routing features this chapter describes. Table 33-2. IP Routing Defaults Parameter Default Value Default Time to Live 64 Routing Mode Disabled globally and on each interface ICMP Echo Replies Enabled ICMP Redirects Enabled ICMP Rate Limit Interval 1000 milliseconds ICMP Rate Limit Burst Size 100 Maximum Next Hops 4 Global Default Gateway None Dynamic ARP Entry Age Time 1200 seconds Automatic Renewal of Dynamic ARP Entries Disabled ARP Response Timeout 1 second ARP Retries 4 Maximum Static ARP Entries 128 IRDP Advertise Mode Disabled IRDP Advertise Address 224.0.0.1 IRDP Maximum Advertise Interval 600 seconds IRDP Minimum Advertise Interval 450 seconds IRDP Advertise Lifetime 1800 seconds IRDP Preference Level 0 Configuring IP Routing 1065 Table 33-2. IP Routing Defaults (Continued) Parameter Default Value Route Preference Values Preference values are as follows: • Local—0 • Static—1 • OSPF Intra—110 • OSPF Inter—110 • OSPF External—110 • RIP—120 ARP Table The router maintains an ARP table that associates a MAC address and outgoing port with an IP address and VLAN. The ARP table is dynamically updated with the host MAC address and outgoing port information. ARP entries are associated with the VLAN on which the IP address or route is known. The router broadcasts an ARP request in the associated VLAN for any unknown MAC address to which it needs to route packets. The router also refreshes an ARP entry by sending an ARP request before a dynamically learned ARP entry times out and updates the ARP table if a response is received. Host or VM movement within the same VLAN (L2 topology change) does not trigger an ARP refresh. Only if the ARP entry is timed out or the port associated with the ARP entry goes down does the ARP entry get refreshed. If the traffic to a host is bidirectional, it will result in the host ARP entry pointing to the new port. Any gratuitous ARP request sent by a host or VM results in an ARP entry update (including a change in the MAC address and outgoing port). 1066 Configuring IP Routing Configuring IP Routing Features (Web) This section provides information about the OpenManage Switch Administrator pages for configuring and monitoring IPv4 routing features on a Dell Networking N2000, N3000, and N4000 series switches. For details about the fields on a page, click at the top of the page. IP Configuration Use the Configuration page to configure routing parameters for the switch as opposed to an interface. The IP configuration settings allow you to enable or disable the generation of various types of ICMP messages. To display the page, click Routing → IP → Configuration in the navigation panel. Figure 33-1. IP Configuration Configuring IP Routing 1067 IP Statistics The IP statistics reported on the Statistics page are as specified in RFC 1213. To display the page, click Routing → IP → Statistics in the navigation panel. Figure 33-2. IP Statistics 1068 Configuring IP Routing ARP Create Use the Create page to add a static ARP entry to the Address Resolution Protocol table. To display the page, click Routing → ARP → Create in the navigation panel. Figure 33-3. ARP Create Configuring IP Routing 1069 ARP Table Configuration Use the Table Configuration page to change the configuration parameters for the Address Resolution Protocol Table. You can also use this screen to display the contents of the table. To display the page, click Routing → ARP → Table Configuration in the navigation panel. Figure 33-4. ARP Table Configuration 1070 Configuring IP Routing Router Discovery Configuration Use the Configuration page to enter or change router discovery parameters. To display the page, click Routing → Router Discovery → Configuration in the navigation panel. Figure 33-5. Router Discovery Configuration Configuring IP Routing 1071 Router Discovery Status Use the Status page to display router discovery data for each interface. To display the page, click Routing → Router Discovery → Status in the navigation panel. Figure 33-6. Router Discovery Status 1072 Configuring IP Routing Route Table Use the Route Table page to display the contents of the routing table. To display the page, click Routing → Router → Route Table in the navigation panel. Figure 33-7. Route Table Configuring IP Routing 1073 Best Routes Table Use the Best Routes Table page to display the best routes from the routing table. To display the page, click Routing → Router → Best Routes Table in the navigation panel. Figure 33-8. Best Routes Table 1074 Configuring IP Routing Route Entry Configuration Use the Route Entry Configuration page to add new and configure router routes. To display the page, click Routing → Router → Route Entry Configuration in the navigation panel. Figure 33-9. Route Entry Configuration Adding a Route and Configuring Route Preference To configure routing table entries: 1 Open the Route Entry Configuration page. Configuring IP Routing 1075 Figure 33-10. Router Route Entry and Preference Configuration 2 Next to Route Type, use the drop-down box to add a Default, Static, or Static Reject route. The fields to configure are different for each route type. • Default — Enter the default gateway address in the Next Hop IP Address field. • Static — Enter values for Network Address, Subnet Mask, Next Hop IP Address, and Preference. • Static Reject — Enter values for Network Address, Subnet Mask, and Preference. 3 Click Apply. The new route is added to the routing table. 1076 Configuring IP Routing Configured Routes Use the Configured Routes page to display the routes that have been manually configured. NOTE: For a static reject route, the next hop interface value is Null0. Packets to the network address specified in static reject routes are intentionally dropped. To display the page, click Routing → Router → Configured Routes in the navigation panel. Figure 33-11. Configured Routes To remove a configured route, select the check box in the Remove column of the route to delete, and click Apply. Configuring IP Routing 1077 Route Preferences Configuration Use the Route Preferences Configuration page to configure the default preference for each protocol (for example 60 for static routes). These values are arbitrary values that range from 1 to 255, and are independent of route metrics. Most routing protocols use a route metric to determine the shortest path known to the protocol, independent of any other protocol. To display the page, click Routing → Router → Route Preferences Configuration in the navigation panel. Figure 33-12. 1078 Router Route Preferences Configuration Configuring IP Routing Configuring IP Routing Features (CLI) This section provides information about the commands you use to configure IPv4 routing on the switch. For more information about the commands, see the Dell Networking N2000, N3000, and N4000 Series Switches CLI Reference Guide at support.dell.com/manuals. Configuring Global IP Routing Settings Beginning in Privileged EXEC mode, use the following commands to configure various global IP routing settings for the switch. Command Purpose configure Enter global configuration mode. ip routing Globally enable IPv4 routing on the switch. ip icmp echo-reply Allow the switch to generate ICMP Echo Reply messages. ip icmp error-interval burst-interval [burstsize] Limit the rate at which IPv4 ICMP error messages are sent. • burst-interval — How often the token bucket is initialized (Range: 0–2147483647 milliseconds). • burst-size — The maximum number of messages that can be sent during a burst interval (Range: 1–200). ip redirects Allow the switch to generate ICMP Redirect messages. ip default-gateway ip- address Configure the global default gateway for the switch. The gateway configured here takes precedence over a default gateway assigned by a network DHCP server. exit Exit to Privileged EXEC mode. show ip brief View the global IP settings for the switch. Configuring IP Routing 1079 Adding Static ARP Entries and Configuring ARP Table Settings Beginning in Privileged EXEC mode, use the following commands to configure static ARP entries in the ARP cache and to specify the settings for the ARP cache. Command Purpose configure Enter global configuration mode. arp ip-address hardware- Create a static ARP entry in the ARP table. address • ip-address — IP address of a device on a subnet attached to an existing routing interface. • hardware-address — A unicast MAC address for that device. arp timeout seconds Configure the ARP entry ageout time. arp resptime seconds Configure the ARP request response timeout. arp retries integer Configure the ARP count of maximum requests for retries. The range is 1–10. arp cachesize integer Configure the maximum number of entries in the ARP cache. arp dynamicrenew Allow the ARP component to automatically renew dynamic ARP entries when they age out. exit Exit to Privileged EXEC mode. show arp [brief] View the user-configured (static) ARP entries. The static entries display regardless of whether they are reachable over an interface. Use the brief keyword to view only the ARP table settings. clear arp-cache [gateway] Remove all dynamic ARP entries from the ARP cache. Include the keyword gateway to remove gateway entries as well. clear arp-cache management Remove all dynamic ARP entries from the ARP cache that were learned on the management interface. arp purge ip-address Remove the specified IP address from the ARP cache. This command removes dynamic and gateway ARP entries only. 1080 Configuring IP Routing Configuring Router Discovery (IRDP) Beginning in Privileged EXEC mode, use the following commands to configure IRDP settings. Command Purpose configure Enter global configuration mode. interface interface Enter interface configuration mode for the specified VLAN routing interface. The interface variable includes the interface type (vlan) and number, for example vlan 100. ip irdp Enable IRDP on the interface. ip irdp address ip-address Configure the address that the interface uses to send the router discovery advertisements. The allowed addresses are 224.0.0.1 (all-hosts IP multicast address) or 255.255.255.255 (limited broadcast address) ip irdp holdtime seconds Configure the value of the holdtime field of the router advertisement sent from this interface. ip irdp maxadvertinterval Configure the maximum time allowed between sending router advertisements from the interface. seconds ip irdp minadvertinterval Configure the minimum time allowed between sending seconds router advertisements from the interface. ip irdp preference integer Configure the preference of the address as a default router address relative to other router addresses on the same subnet. exit Exit to Global Config mode. exit Exit to Privileged EXEC mode. show ip irdp [vlan vlan-id] View the router discovery information for all interfaces, or for a specified interface. Configuring IP Routing 1081 Configuring Route Table Entries and Route Preferences Beginning in Privileged EXEC mode, use the following commands to configure IRDP settings. Command Purpose configure Enter global configuration mode. Configure the default route. ip route default nextHopRtr [preference ] • nextHopRtr — IP address of the next hop router. • preference — Specifies the preference value (administrative distance) of an individual static route. (Range: 1-255) ip route ip-addr {subnetmask | prefix length } {nextHopRtr | null} [preference ] Configure a static route. Use the keyword null instead of the next hop router IP address to configure a static reject route. • ip-address — IP address of destination interface. • subnet-mask — Subnet mask of destination interface. • prefix-length — Length of prefix. Must be preceded with a forward slash (/). (Range: 0-32 bits) • nextHopRtr — IP address of the next hop router. • null — Specifies that the route is a static reject route. • preference — Specifies the preference value (administrative distance) of an individual static route. (Range: 1-255) ip route distance integer Set the default distance (preference) for static routes. Lower route preference values are preferred when determining the best route. exit Exit to Privileged EXEC mode. 1082 Configuring IP Routing Command Purpose show ip route [ip-address [mask | prefix-length] [longer-prefixes] | protocol] View the routing table. • ip-address — Specifies the network for which the route is to be displayed and displays the best matching bestroute for the address. • mask — Subnet mask of the IP address. • prefix-length — Length of prefix, in bits. Must be preceded with a forward slash (‘/’). (Range: 0-32 bits) • longer-prefixes — Indicates that the ip-address and subnet-mask pair becomes the prefix, and the command displays the routes to the addresses that match that prefix. • protocol — Specifies the protocol that installed the routes. (Range: connected, ospf, rip, static) show ip route configured View the configured routes, whether they are reachable or not. show ip route summary View summary information about the routing table. show ip protocols View the parameters and current state of the active routing protocols. show ip route preferences View detailed information about the route preferences. Configuring IP Routing 1083 IP Routing Configuration Example In this example, the Dell Networking switches are L3 switches with VLAN routing interfaces. VLAN routing is configured on Dell Networking Switch A and Dell Networking Switch B. This allows the host in VLAN 10 to communicate with the server in VLAN 30. A static route to the VLAN 30 subnet is configured on Switch A. Additionally, a default route is configured on Switch A so that all traffic with an unknown destination is sent to the backbone router through port 24, which is a member of VLAN 50. A default route is configured on Dell Networking Switch B to use Switch A as the default gateway. The hosts use the IP address of the VLAN routing interface as their default gateway. This example assumes that all L2 VLAN information, such as VLAN creation and port membership, has been configured. Figure 33-13. 1084 IP Routing Example Topology Configuring IP Routing Configuring Dell Networking Switch A To configure Switch A. 1 Enable routing on the switch. console#configure console(config)#ip routing 2 Assign an IP address to VLAN 10. This command also enables IP routing on the VLAN. console(config)#interface vlan 10 console(config-if-vlan10)#ip address 192.168.10.10 255.255.255.0 console(config-if-vlan10)#exit 3 Assign an IP address to VLAN 20. console#configure console(config)#interface vlan 20 console(config-if-vlan20)#ip address 192.168.20.20 255.255.255.0 console(config-if-vlan20)#exit 4 Assign an IP address to VLAN 50. console#configure console(config)#interface vlan 50 console(config-if-vlan50)#ip address 192.168.50.50 255.255.255.0 console(config-if-vlan50)#exit 5 Configure a static route to the network that VLAN 30 is in, using the IP address of the VLAN 20 interface on Switch B as the next hop address. console(config)#ip route 192.168.30.0 255.255.255.0 192.168.20.25 6 Configure the backbone router interface as the default gateway. console(config)#ip route default 192.168.50.2 Configuring IP Routing 1085 Configuring Dell Networking Switch B To configure Switch B: 1 Enable routing on the switch. console#configure console(config)#ip routing 2 Assign an IP address to VLAN 20. This command also enables IP routing on the VLAN. console#configure console(config)#interface vlan 20 console(config-if-vlan20)#ip address 192.168.20.25 255.255.255.0 console(config-if-vlan20)#exit 3 Assign an IP address to VLAN 30. This command also enables IP routing on the VLAN. console#configure console(config)#interface vlan 30 console(config-if-vlan30)#ip address 192.168.30.30 255.255.255.0 console(config-if-vlan30)#exit 4 Configure the VLAN 20 routing interface on Switch A as the default gateway so that any traffic with an unknown destination is sent to Switch A for forwarding. console(config)#ip route default 192.168.20.20 1086 Configuring IP Routing Configuring L2 and L3 Relay Features 34 This chapter describes how to configure the L2 DHCP Relay, L3 DHCP Relay, and IP Helper features on Dell Networking series switches. The topics covered in this chapter include: • L2 and L3 Relay Overview • Default L2/L3 Relay Values • Configuring L2 and L3 Relay Features (Web) • Configuring L2 and L3 Relay Features (CLI) • Relay Agent Configuration Example L2 and L3 Relay Overview When a DHCP client and server are in the same IP subnet, they can directly connect to exchange IP address requests and replies. However, buying and maintaining a DHCP server on each subnet can be expensive and is often impractical. The relay features on the Dell Networking series switches can help enable communication between DHCP clients and DHCP servers that reside in different subnets. Configuring L3 DHCP relay also enables the bootstrap protocol (BOOTP) relay. What Is L3 DHCP Relay? Network infrastructure devices can be used to relay packets between a DHCP client and server on different subnets. Such a device, an Layer 3 Relay agent, is often a router or L3 switch. The L3 relay agent must have an IP interface on the client subnets and, if it does not have an IP interface on the server’s subnet, it should be able to route traffic toward the server’s subnet. The Dell Networking DHCP Relay Agent enables DHCP clients and servers to exchange DHCP messages across different subnets. The relay agent receives the requests from the clients, and checks the valid hops and giaddr Configuring L2 and L3 Relay Features 1087 fields in the DHCP request. If the number of hops is greater than the configured number, the agent discards the packet. If the giaddr field is zero, the agent must fill in this field with the IP address of the interface on which the request was received. The agent unicasts the valid packets to all configured DHCP servers. Each server responds with a unicast BOOTREPLY addressed to the relay agent closest to the client as indicated by giaddr field. Upon reception of the BOOTREPLY from the server, the agent forwards this reply as broadcast or unicast on the interface where the BOOTREQUEST arrived. This interface can be identified by the giaddr field or option 82. The Dell Networking N2000, N3000, and N4000 series switches DHCP component also supports DHCP relay agent options to identify the client interface. If configured, the relay agent inserts these options when forwarding the request to the server and removes them when sending the reply to the clients. If an interface has more than one IP address, the relay agent uses the primary IP address configured as its relay agent IP address. What Is L2 DHCP Relay? In Layer 2 switched networks, there may be one or more infrastructure devices (for example, a switch) between the client and the L3 Relay agent/DHCP server. In this instance, some of the client device information required by the L3 Relay agent may not be included in the DHCP packets sent by the DHCP client. In this case, an L2 Relay agent can be used to add the information that the L3 Relay Agent and DHCP server need to perform their roles in address and configuration and assignment. Before it relays DHCP requests from clients, the switch can add a Circuit ID and a Remote ID. These IDs provide information about the circuit and port number connected to the client. This information is added as suboptions in the DHCP Option 82 packets as defined in sections 3.1 and 3.2 of RFC3046. The switch removes this option from packets that it relays from L3 Relay agents/DHCP servers to clients. These sub-options may be used by the DHCP server to affect how it treats the client and also may be used by the relay agent to limit broadcast replies to the specific circuit or attachment point of the client. 1088 Configuring L2 and L3 Relay Features Enabling L2 Relay on VLANs You can enable L2 DHCP relay on a particular VLAN. The VLAN is identified by a service VLAN ID (S-VID), which a service provider uses to identify a customer’s traffic while traversing the provider network to multiple remote sites. The switch uses the VLAN membership of the switch port client (the customer VLAN ID, or C-VID) to perform a lookup a corresponding S-VID. If the S-VID is enabled for DHCP Relay, then the packet can be forwarded. If the C-VID does not correspond to an S-VID that is enabled for DHCP Relay, then the switch will not relay the DHCP request packet. What Is the IP Helper Feature? The IP Helper feature provides the ability for a router to forward configured UDP broadcast packets to a particular IP address. This allows applications to reach servers on non-local subnets. This is possible even when the application is designed to assume a server is always on a local subnet or when the application uses broadcast packets to reach the server (with the limited broadcast address 255.255.255.255, or a network directed broadcast address). You can configure relay entries globally and on routing interfaces. Each relay entry maps an ingress interface and destination UDP port number to a single IPv4 address (the helper address). Multiple relay entries may be configured for the same interface and UDP port, in which case the relay agent relays matching packets to each server address. Interface configuration takes priority over global configuration. If the destination UDP port for a packet matches any entry on the ingress interface, the packet is handled according to the interface configuration. If the packet does not match any entry on the ingress interface, the packet is handled according to the global IP helper configuration. You can configure discard relay entries. Discard entries are used to discard packets received on a specific interface when those packets would otherwise be relayed according to a global relay entry. Discard relay entries may be configured on interfaces, but are not configured globally. Additionally, you can configure which UDP ports are forwarded. Certain UDP port numbers can be selected from the web interface or specified by name in the CLI, but you can also configure a relay entry with any UDP port number. You may configure relay entries that do not specify a destination UDP port. The relay agent assumes that these entries match packets with the UDP destination ports listed in Table 34-1 (the list of default ports). Configuring L2 and L3 Relay Features 1089 Table 34-1. Default Ports - UDP Port Numbers Implied By Wildcard Protocol UDP Port Number IEN-116 Name Service 42 DNS 53 NetBIOS Name Server 137 NetBIOS Datagram Server 138 TACACS Server 49 Time Service 37 DHCP 67 Trivial File Transfer Protocol 69 The system limits the total number of relay entries to four times the maximum number of routing interfaces (512 relay entries). There is no individual limit to the number of relay entries on an individual interface, and no individual limit to the number of servers for a given {interface, UDP port} pair. The system limit applies in these cases. Certain configurable DHCP relay options do not apply to relay of other protocols. You may optionally set a maximum hop count or minimum wait time using the bootpdhcprelay maxhopcount and bootpdhcprelay minwaittime commands. The relay agent relays DHCP packets in both directions. It relays broadcast packets from the client to one or more DHCP servers, and relays packets to the client that the DHCP server unicasts back to the relay agent. For other protocols, the relay agent only relays broadcast packets from the client to the server. Packets from the server back to the client are assumed to be unicast directly to the client. Because there is no relay in the return direction for protocols other than DHCP, the relay agent retains the source IP address from the original client packet. The relay agent uses a local IP address as the source IP address of relayed DHCP client packets. When a switch receives a broadcast UDP packet on a routing interface, the relay agent verifies that the interface is configured to relay to the destination UDP port. If so, the relay agent unicasts the packet to the configured server IP addresses. Otherwise, the relay agent verifies that there is a global 1090 Configuring L2 and L3 Relay Features configuration for the destination UDP port. If so, the relay agent unicasts the packet to the configured server IP addresses. Otherwise the packet is not relayed. NOTE: If the packet matches a discard relay entry on the ingress interface, the packet is not forwarded, regardless of the global configuration. The relay agent relays packets that meet only the following conditions: • The destination MAC address must be the all-ones broadcast address (FF:FF:FF:FF:FF:FF). • The destination IP address must be the limited broadcast address (255.255.255.255) or a directed broadcast address for the receive interface. • The IP time-to-live (TTL) must be greater than 1. • The protocol field in the IP header must be UDP (17). • The destination UDP port must match a configured relay entry. Configuring L2 and L3 Relay Features 1091 Table 34-2 shows the most common protocols and their UDP port numbers and names that are relayed. Table 34-2. UDP Port Allocations UDP Port Number Acronym Application 7 Echo Echo 11 SysStat Active User 15 NetStat NetStat 17 Quote Quote of the day 19 CHARGEN Character Generator 20 FTP-data FTP Data 21 FTP FTP 37 Time Time 42 NAMESERVER Host Name Server 43 NICNAME Who is 53 DOMAIN Domain Name Server 69 TFTP Trivial File Transfer 111 SUNRPC Sun Microsystems Rpc 123 NTP Network Time 137 NetBiosNameService NT Server to Station Connections 138 NetBiosDatagramService NT Server to Station Connections 139 NetBios SessionServiceNT Server to Station Connections 161 SNMP Simple Network Management 162 SNMP-trap Simple Network Management Traps 513 who Unix Rwho Daemon 514 syslog System Log 525 timed Time Daemon 1092 Configuring L2 and L3 Relay Features Default L2/L3 Relay Values By default L2 DHCP relay is disabled. L3 relay (UDP) is enabled, but no UDP destination ports or server addresses are defined on the switch or on any interfaces. Table 34-3. L2/L3 Relay Defaults Parameter Default Value L2 DHCP Relay Admin Mode Disabled globally and on all interfaces and VLANs Trust Mode Disabled on all interfaces Circuit ID Disabled on all VLANs Remote ID None configured L3 DHCP Relay UDP Relay Mode (IP Helper) Enabled Hop Count 4 Minimum Wait Time 0 seconds Circuit ID Option Mode Disabled Circuit ID Check Mode Enabled Information Option-Insert Disabled on all VLAN interfaces Information Check-Reply Enabled on all VLAN interfaces Configuring L2 and L3 Relay Features 1093 Configuring L2 and L3 Relay Features (Web) This section provides information about the OpenManage Switch Administrator pages for configuring and monitoring L2 and L3 relay features on a Dell Networking N2000, N3000, and N4000 series switches. For details about the fields on a page, click at the top of the page. DHCP Relay Global Configuration Use this page to enable or disable the switch to act as a DHCP Relay agent. This functionality must also be enabled on each port you want this service to operate on (see "DHCP Relay Interface Configuration" on page 1095). The switch can also be configured to relay requests only when the VLAN of the requesting client corresponds to a service provider’s VLAN ID that has been enabled with the L2 DHCP relay functionality (see "DHCP Relay VLAN Configuration" on page 1098). To access this page, click Switching → DHCP Relay → Global Configuration in the navigation panel. Figure 34-1. DHCP Relay Global Configuration 1094 Configuring L2 and L3 Relay Features DHCP Relay Interface Configuration Use this page to enable L2 DHCP relay on individual ports. NOTE: L2 DHCP relay must also be enabled globally on the switch. To access this page, click Switching → DHCP Relay → Interface Configuration in the navigation panel. Figure 34-2. DHCP Relay Interface Configuration To view a summary of the L2 DHCP relay configuration on all ports and LAGS, click Show All. Configuring L2 and L3 Relay Features 1095 Figure 34-3. DHCP Relay Interface Summary 1096 Configuring L2 and L3 Relay Features DHCP Relay Interface Statistics Use this page to display statistics on DHCP Relay requests received on a selected port. To access this page, click Switching → DHCP Relay → Interface Statistics in the navigation panel. Figure 34-4. DHCP Relay Interface Statistics Configuring L2 and L3 Relay Features 1097 DHCP Relay VLAN Configuration Use this page to enable and configure DHCP Relay on specific VLANs. To access this page, click Switching → DHCP Relay → VLAN Configuration in the navigation panel. Figure 34-5. DHCP Relay VLAN Configuration To view a summary of the L2 DHCP relay configuration on all VLANs, click Show All. Figure 34-6. DHCP Relay VLAN Summary DHCP Relay Agent Configuration Use the Configuration page to configure and display a DHCP relay agent. 1098 Configuring L2 and L3 Relay Features To display the page, click Routing → BOOTP/DHCP Relay Agent → Configuration in the navigation panel. Figure 34-7. DHCP Relay Agent Configuration Configuring L2 and L3 Relay Features 1099 IP Helper Global Configuration Use the Global Configuration page to add, show, or delete UDP Relay and Helper IP configuration To display the page, click Routing → IP Helper → Global Configuration in the navigation panel. Figure 34-8. IP Helper Global Configuration Adding an IP Helper Entry To configure an IP helper entry: 1. Open the IP Helper Global Configuration page. 2. Click Add to display the Add Helper IP Address page: 1100 Configuring L2 and L3 Relay Features Figure 34-9. Add Helper IP Address 3. Select a UDP Destination port name from the menu or enter the UDP Destination Port ID. Select the Default Set to configure for the relay entry for the default set of protocols. NOTE: If the DefaultSet option is specified, the device by default forwards UDP Broadcast packets for the following services: IEN-116 Name Service (port 42), DNS (port 53), NetBIOS Name Server (port 137), NetBIOS Datagram Server (port 138), TACACS Server (Port 49), and Time Service (port 37). 4. Enter the IP address of the server to which the packets with the given UDP Destination Port will be relayed. 5. Click Apply. The UDP/Helper Relay is added and the device is updated. Configuring L2 and L3 Relay Features 1101 IP Helper Interface Configuration Use the Interface Configuration page to add, show, or delete UDP Relay and Helper IP configuration for a specific interface. To display the page, click Routing → IP Helper → Interface Configuration in the navigation panel. Figure 34-10. IP Helper Interface Configuration Adding an IP Helper Entry to an Interface To add an IP helper entry to an interface: 1. Open the IP Helper Interface Configuration page. 2. Click Add to display the Add IP Helper Address page: 1102 Configuring L2 and L3 Relay Features Figure 34-11. Add Helper IP Address 3. Select the interface to use for the relay. 4. Select a UDP Destination port name from the menu or enter the UDP Destination Port ID. Select the Default Set to configure for the relay entry for the default set of protocols. NOTE: If the DefaultSet option is specified, the device by default forwards UDP Broadcast packets for the following services: IEN-116 Name Service (port 42), DNS (port 53), NetBIOS Name Server (port 137), NetBIOS Datagram Server (port 138), TACACS Server (Port 49), and Time Service (port 37). 5. Choose whether to discard (True) or keep (False) packets arriving on the given interface with the given destination UDP port. 6. Enter the IP address of the server to which the packets with the given UDP Destination Port will be relayed. 7. Click Apply. The UDP/Helper Relay is added to the interface and the device is updated. Configuring L2 and L3 Relay Features 1103 IP Helper Statistics Use the Statistics page to view UDP Relay Statistics for the switch. To display the page, click Routing → IP Helper → Statistics in the navigation panel. Figure 34-12. 1104 IP Helper Statistics Configuring L2 and L3 Relay Features Configuring L2 and L3 Relay Features (CLI) This section provides information about the commands you use to configure L2 and L3 relay features on the switch. For more information about the commands, see the Dell Networking N2000, N3000, and N4000 Series Switches CLI Reference Guide at support.dell.com/manuals. Configuring L2 DHCP Relay Beginning in Privileged EXEC mode, use the following commands to configure switch and interface L2 DHCP relay settings. Command Purpose configure Enter global configuration mode. dhcp l2relay Globally enable L2 DHCP relay on the switch interface interface Enter interface configuration mode for the specified port or LAG. The interface variable includes the interface type and number, for example tengigabitethernet 1/0/3. For a LAG, the interface type is port-channel. You can also specify a range of ports with the interface range command, for example, interface range tengigabitethernet 1/0/8-12 configures interfaces 8, 9, 10, 11, and 12. dhcp l2relay Enable L2 DHCP relay on the port(s) or LAG(s). dhcp l2relay trust Configure the interface(s) to mandate Option-82 on receiving DHCP packets. exit Exit to Global Configuration mode. dhcp l2relay vlan vlan- Enable the L2 DHCP Relay agent for a set of VLANs. All DHCP packets which arrive on interfaces in the configured VLAN are subject to L2 Relay processing. dhcp l2relay circuit-id vlan vlan-range Enable setting the DHCP Option 82 Circuit ID for a VLAN. When enabled, the interface number is added as the Circuit ID in DHCP option 82. range Configuring L2 and L3 Relay Features 1105 Command Purpose dhcp l2relay remote-id Enable setting the DHCP Option 82 Remote ID for a remoteId vlan vlan-range VLAN. When enabled, the supplied string is used for the Remote ID in DHCP Option 82. The remoteId variable is a string to be used as the remote ID in the Option 82 (Range: 1 - 128 characters). exit Exit to Privileged EXEC mode. show dhcp l2relay all View L2 DHCP relay settings on the switch. View L2 DHCP relay settings for all interfaces or for the show dhcp l2relay interface [all | interface] specified interface. show dhcp l2relay vlan vlan-range View L2 DHCP relay settings for the specified VLAN show dhcp l2relay stats View the number of DHCP packets processed and relayed interface [all | interface] by the L2 relay agent. To reset the statistics to 0, use the clear dhcp l2relay statistics interface [all | interface] command. show dhcp l2relay agent- View the DHCP L2 Relay Option-82 configuration for the option vlan vlan-id specified VLAN. show dhcp l2relay circuit-id vlan vlan-id View the DHCP L2 Relay circuit ID configuration for the specified VLAN. show dhcp l2relay remote-id vlan vlan-id View the DHCP L2 Relay remote ID configuration for the specified VLAN. 1106 Configuring L2 and L3 Relay Features Configuring L3 Relay (IP Helper) Settings Beginning in Privileged EXEC mode, use the following commands to configure switch and interface L3 DHCP relay and IP helper settings. Command Purpose configure Enter global configuration mode. ip helper enable Use this command to enable the IP helper feature. It is enabled by default. ip helper-address serveraddress [dest-udp-port | dhcp | domain | isakmp | mobile-ip | nameserver | netbiosdgm | netbios-ns | ntp | pim-auto-rp | rip | tacacs | tftp | time] Configure the relay of certain UDP broadcast packets received on any interface. Specify the one of the protocols defined in the command or the UDP port number. interface vlan vlan-id Enter interface configuration mode for the specified VLAN routing interface. • server-address — The IPv4 unicast or directed broadcast address to which relayed UDP broadcast packets are sent. The server address cannot be an IP address configured on any interface of the local router. • dest-udp-port — A destination UDP port number from 0 to 65535. You can also specify a range of VLAN routing interfaces with the interface range vlan command, for example, interface range vlan 10,20,30 configures VLAN interfaces 10, 20, and 30. NOTE: All VLANs must be configured as VLAN routing interfaces. Configuring L2 and L3 Relay Features 1107 Command Purpose ip helper-address {server-address | discard} [dest-udp-port | dhcp | domain | isakmp | mobile-ip | nameserver | netbiosdgm | netbios-ns | ntp | pim-auto-rp | rip | tacacs | tftp | time] Configure the relay of certain UDP broadcast packets received on the VLAN routing interface(s). This command takes precedence over an ip helper-address command given in global configuration mode. Specify the one of the protocols defined in the command or the UDP port number. • server-address — The IPv4 unicast or directed broadcast address to which relayed UDP broadcast packets are sent. The server address cannot be an IP address configured on any interface of the local router. • dest-udp-port — A destination UDP port number from 0 to 65535. exit Exit to Global Config mode. exit Exit to Privileged EXEC mode. show ip helper-address [vlan vlan-id] View IP helper (L3 relay) settings for all interfaces or for the specified VLAN routing interface. show ip helper statistics View the number of DHCP and other UDP packets processed and relayed by the UDP relay agent. To reset the statistics to 0, use the clear ip helper statistics command. 1108 Configuring L2 and L3 Relay Features Relay Agent Configuration Example The example in this section shows how to configure the L3 relay agent (IP helper) to relay and discard various protocols. Figure 34-13. L3 Relay Network Diagram DHCP Server 192.168.40.22 DNS Server 192.168.40.43 DHCP Server 192.168.40.35 SNMP Server 192.168.23.1 VLAN 30 L3 Switch ` DHCP Clients VLAN 10 ` ` ` VLAN 20 (No DHCP) This example assumes that multiple VLAN routing interfaces have been created, and configured with IP addresses. To configure the switch: 1 Relay DHCP packets received on VLAN 10 to 192.168.40.35 console#config console(config)#interface vlan 10 console(config-if-vlan10)#ip helper-address 192.168.40.35 dhcp Configuring L2 and L3 Relay Features 1109 2 Relay DNS packets received on VLAN 10 to 192.168.40.43 console(config-if-vlan10)#ip helper-address 192.168.40.35 domain console(config-if-vlan10)#exit 3 Relay SNMP traps (port 162) received on VLAN 20 to 192.168.23.1 console(config)#interface vlan 20 console(config-if-vlan20)#ip helper-address 192.168.23.1 162 4 The clients on VLAN 20 have statically-configured network information, so the switch is configured to drop DHCP packets received on VLAN 20 console(config-if-vlan20)#ip helper-address discard dhcp console(config-if-vlan20)#exit 5 DHCP packets received from clients in any VLAN other than VLAN 10 and VLAN 20 are relayed to 192.168.40.22. NOTE: The following command is issued in Global Configuration mode, so it applies to all interfaces except VLAN 10 and VLAN 20. IP helper commands issued in Interface Configuration mode override the commands issued in Global Configuration Mode. console(config)#ip helper-address 192.168.40.22 dhcp 6 Verify the configuration. console#show ip helper-address IP helper is enabled I/F ---Vl10 Vl10 Vl20 Vl20 Any 1110 UDP Port -------domain dhcp dhcp 162 dhcp Discard ----No No Yes No No Hit Count --------0 0 0 0 0 Configuring L2 and L3 Relay Features Server Address --------------192.168.40.43 192.168.40.35 192.168.23.1 192.168.40.22 35 Configuring OSPF and OSPFv3 This chapter describes how to configure Open Shortest Path First (OSPF) and OSPFv3. OSPF is a dynamic routing protocol for IPv4 networks, and OSPFv3 is used to route traffic in IPv6 networks. The protocols are configured separately within the software, but their functionality is largely similar for IPv4 and IPv6 networks. NOTE: In this chapter references to OSPF apply to OSPFv2 and OSPFv3 unless otherwise noted. NOTE: N2000 switches do not support OSPF. The topics covered in this chapter include: • OSPF Overview • OSPF Feature Details • Default OSPF Values • Configuring OSPF Features (Web) • Configuring OSPFv3 Features (Web) • Configuring OSPF Features (CLI) • Configuring OSPFv3 Features (CLI) • OSPF Configuration Examples Configuring OSPF and OSPFv3 1111 OSPF Overview OSPF is an Interior Gateway Protocol (IGP) that performs dynamic routing within a network. Dell Networking series switches support two dynamic routing protocols: OSPF and Routing Information Protocol (RIP). Unlike RIP, OSPF is a link-state protocol. Larger networks typically use the OSPF protocol instead of RIP. What Are OSPF Areas and Other OSPF Topology Features? The top level of the hierarchy of an OSPF network is known as an OSPF domain. The domain can be divided into areas. Routers within an area must share detailed information on the topology of their area, but require less detailed information about the topology of other areas. Segregating a network into areas enables limiting the amount of route information communicated throughout the network. Areas are identified by a numeric ID in IP address format n.n.n.n (note, however, that these are not used as actual IP addresses). For simplicity, the area can be configured and referred to in normal integer notation. For example, Area 20 is identified as 0.0.0.20 and Area 256 as 0.0.1.0. The area identified as 0.0.0.0 is referred to as Area 0 and is considered the OSPF backbone. All other OSPF areas in the network must connect to Area 0 directly or through a virtual link. The backbone area is responsible for distributing routing information between non-backbone areas. A virtual link can be used to connect an area to Area 0 when a direct link is not possible. A virtual link traverses an area between the remote area and Area 0. A stub area is an area that does not accept external LSAs (LSAs generated by redistributing routes) that were learned from a protocol other than OSPF or were statically configured. These routes typically send traffic outside the AS. Therefore, routes from a stub area to locations outside the AS use the default gateway. A virtual link cannot be configured across a stub area. A Not So Stubby Area can import limited external routes only from a connected ASBR. 1112 Configuring OSPF and OSPFv3 What Are OSPF Routers and LSAs? When a Dell Networking switch is configured to use OSPF for dynamic routing, it is considered to be an OSPF router. OSPF routers keep track of the state of the various links they send data to. Routers exchange OSPF link state advertisements (LSAs) with other routers. External LSAs provide information on static routes or routes learned from other routing protocols. OSPF defines various router types: • Backbone routers have an interface in Area 0. • Area border routers (ABRs) have interfaces in multiple areas. • Internal routers have all their interfaces in a single OSPF area. • Autonomous system boundary routers (ASBRs) redistribute routes from other protocols and originate external LSAs. How Are Routes Selected? OSPF determines the best route using the route metric and the type of the OSPF route. The following order is used for choosing a route if more than one type of route exists: 1 Intra-area (the destination prefix is in the same area as the router computing the route) 2 Inter-area (the destination is not in the same area as the router computing the route 3 External Type 1 4 External Type 2 How Are OSPF and OSPFv3 Different? OSPFv3 is the Open Shortest Path First routing protocol for IPv6. It is similar to OSPFv2 in its concept of a link state database, intra/inter area, and AS external routes and virtual links. It differs from its IPv4 counterpart in a number of respects. Peering is done through link-local addresses, and the protocol is link rather than network centric; and addressing semantics have been moved to leaf LSAs. Configuring OSPF and OSPFv3 1113 OSPF Feature Details This section provides details on the following OSPF features: • Max Metric • Static Area Range Cost • LSA Pacing • LSA Pacing Max Metric RFC 3137 introduced stub router behavior to OSPFv2. As a stub, a router can inform other routers that it is not available to forward data packets. This can be useful if OSPF has run out of resources (for example, memory) to compute a complete routing table, or to avoid routing transients as OSPF learns its neighbors and a complete set of routes at startup. Thus, OSPF can enter stub router mode either automatically (as a result of a resource condition) or by configuration. When OSPF enters stub router mode, it re-originates its router LSAs and sets the metric on each of its non-stub links to the maximum value, 0xFFFF. Whenever OSPF originates a router LSA while in stub router mode, it sets the metrics in this way. Stub router mode is global and applies to router LSAs for all areas. Other routers prefer alternate paths that avoid the stub router; however, if no alternate path is available, another router may compute a transit route through a stub router. Because the stub router does not adjust the metric for stub links in its router LSA, routes to destinations on these networks are unaffected. Thus, stub router mode does not affect management connections to the router, even if the router and management station depend on OSPF routes to communicate with each other. The feature supports two modes of operation. The network administrator can put OSPF in stub router mode. OSPF remains in stub router mode until the network administrator takes OSPF out of stub router mode. Alternatively, the network administrator can configure OSPF to start in stub router mode for a configurable period of time after the router boots up. On a stack, the startup period also applies when a unit takes over as the management unit. The clear configuration command also restarts OSPF in stub router 1114 Configuring OSPF and OSPFv3 mode. OSPF does not begin in stub router mode when OSPF is globally enabled. If the operator wants to avoid routing transients when he enables or configures OSPF, he can manually set OSPF in stub router mode. If OSPF is in startup stub router mode and encounters a resource limitation that would normally cause OSPF to become a stub router, OSPF cancels the timer to exit startup stub router and remains in stub router mode until the network administrator takes action. The network administrator can optionally configure OSPF to override the metric in summary LSAs while in stub router mode. The option applies to both type 3 and type 4 summary LSAs. When a router is in stub router mode, all its virtual links are down. This is because the cost to the virtual neighbor is guaranteed to be greater than or equal to 0xFFFF. RFC 2328 section 15 states that: “...a virtual link whose underlying path has cost greater than hexadecimal 0xffff (the maximum size of an interface cost in a router-LSA) should be considered non-operational.” To configure a router for stub router mode, use the max-metric routerlsa command in Global Router Configuration mode. The following example sets the router to start in stub router mode on a restart and remain in stub router mode for 5 minutes: ABR-R0(config)#router ospf ABR-R0(config-router)#max-metric router-lsa on-startup 300 The following example sets the router to advertise the metric in type 3 and type 4 summary LSAs as 32768 for 5 minutes after a restart, after which time the router will exit stub router mode and advertise the full set of LSAs: ABR-R0(config)#router ospf ABR-R0(config-router)#max-metric router-lsa on-startup 300 summarylsa 32768 The following example causes the router to exit stub router mode, whether entered automatically due to resource constraints or due to configuration by the operator. Virtual links are enabled when the router exits stub router mode. ABR-R0(config)#router ospf ABR-R0(config-router)#no max-metric router-lsa Configuring OSPF and OSPFv3 1115 Static Area Range Cost This feature allows a network operator to configure a fixed OSPF cost that is always advertised when an area range is active. This feature applies to both OSPFv2 and OSPFv3. An OSPF domain can be divided into areas to limit the processing required on each router. Area Border Routers (ABRs) advertise reachability across area boundaries. It is common to summarize the set of prefixes that an ABR advertises across an area boundary. RFC 2328 specifies that when an ABR originates a type 3 LSA for an active area range, the cost in the LSA is set to “the largest cost of any of the component networks.” Thus, when an area's topology changes in a way that increases the largest cost, the type 3 LSA must be re-originated. In some cases, advertising the change in cost may be less important than preventing the topology change from propagating outside the area (thus causing routers in other areas to process and flood a changed LSA and rerun their routing table calculations). For this reason, it is common to give the network administrator the option of configuring the cost for an area range. When a static cost is configured, the cost advertised in the type 3 LSA does not depend on the cost of the component networks. Thus, topology changes within an area do not propagate outside the area, resulting in greater stability within the OSPF domain. Dell Networking switches also use area ranges to summarize type 7 LSAs when they are translated to type 5 LSAs. The cost option may be configured on area ranges used for type 7 to type 5 translation. If an area range is configured for type 3 summarization and the static cost is set to the maximum value, 16,777,215, the range is not advertised. Setting this static cost is equivalent to configuring a range with the not-advertise option. A summary LSA with this metric (LSInfinity) cannot be advertised, according to RFC 2328 section 12.4.3. This behavior is consistent with the industry standard. If an area range is configured for type 7 to type 5 translation, a type 5 LSA is sent if the metric is set to 16,777,215; however, other routers will not compute a route from a type 5 LSA with this metric. See "Configuring the Static Area Range Cost" on page 1190 for a configuration example. 1116 Configuring OSPF and OSPFv3 LSA Pacing OSPF refreshes each self-originated LSA every 30 minutes. Because a router tends to originate many LSAs at the same time, either at startup or when adjacencies are formed or when routes are first learned, LSA refreshes tend to be grouped. Further, Area Border Routers (ABRs) attached to the same area tend to originate summary LSAs into the area at the same time. This behavior leads to periodic bursts of LS Update packets. Update bursts can lead to high CPU utilization, packet loss, and retransmission, if a receiver cannot absorb all packets in a burst. These losses occur primarily in two places: 1) at the Class of Service (CoS) queue where the hardware queues packets to the CPU, and 2) when a message buffer is allocated for an incoming packet. This feature makes changes to OSPFv2 to improve the efficiency of LSA flooding, with the expectation that the improvements will greatly reduce or eliminate the packet drops caused by bursts in OSPF control packets. The changes are as follows: • Introduce LSA transmit pacing, limiting the rate of LS Update packets that OSPF can send • Introduce LSA refresh groups, so that OSPF efficiently bundles LSAs into LS Update packets when periodically refreshing self-originated LSAs To configure LSA transmit pacing, use the timers pacing flood command in router config mode: ABR-R0(config)#router ospf ABR-R0(config-router)#timers pacing flood 50 This will cause LSA Update packets to be sent at no less than a 50 millisecond interval. When OSPF refreshes LSAs, it considers all self-originated LSAs whose age is from 1800 to 1800 plus the pacing group size. Grouping LSAs for refresh allows OSPF to combine refreshed LSAs into a minimal number of LS Update packets. Minimizing the number of Update packets makes LSA distribution more efficient. To configure an LSA Refresh window, use the timers pacing lsa-group command in router-config mode: ABR-R0(config)#router ospf ABR-R0(config-router)#timers pacing lsa-group 300 This sets the LSA Refresh window to 2100 seconds or about 35 minutes. Configuring OSPF and OSPFv3 1117 Flood Blocking OSPF is a link state routing protocol. Routers describe their local environment in Link State Advertisements (LSAs), which are distributed throughout an area or OSPF domain. Through this process, each router learns enough information to compute a set of routes consistent with the routes computed by all other routers. Normally, OSPF floods an LSA on all interfaces within the LSA's flooding scope. Flooding ensures that all routers receive all LSAs. A router normally receives a duplicate copy of each LSA once on each interface in the LSA's flooding scope. The duplicate deliveries make OSPF LSA distribution robust, but in highly interconnected networks, can cause a lot of buffer and CPU usage. Buffer and CPU use can be reduced by selectively blocking LSA flooding on some interfaces, while ensuring that LSAs are flooded on enough interfaces to guarantee delivery of all LSAs to all routers. When enabling flood blocking, the network administrator must ensure there is sufficient LSA flooding even when there are router and link failures. This feature enables a network administrator to disable LSA flooding on an interface. Flood blocking only affects flooding of LSAs with area or AS (i.e., domain-wide) scope. Such LSAs are expected to be flooded to neighbors on other, unblocked interfaces, and eventually reach neighbors on blocked interfaces. An LSA with interface flooding scope cannot be blocked; there is no other way for interface-scope LSAs to reach neighbors on the blocked interface. Allowing interface-scope LSAs on blocked interfaces allows graceful restart to work, even if the restarting router has neighbors on flood blocked interfaces. When an interface is blocked, LSAs with area or AS scope are not sent to any neighbor on that interface. When flood blocking is enabled, OSPF does not advertise any LSAs with area or AS scope in its database description packets sent to neighbors on a blocked interface. When OSPF receives an LSA from a neighbor and the local database copy is newer than the received LSA, OSPF normally sends the newer LSA directly to the neighbor. If the neighbor is on a blocked interface, OSPF neither acknowledges the LSA nor sends the newer LSA. Instead, OSPF expects that the neighbor will receive the newer LSA indirectly. Flooding is enabled by default. 1118 Configuring OSPF and OSPFv3 Flood blocking cannot be enabled on virtual interfaces. While the feature could be allowed on virtual interfaces, it is less likely to be used on a virtual interface, since virtual interfaces are created specifically to allow flooding between two backbone routers. So the option of flood blocking on virtual interfaces is not supported. See "Configuring Flood Blocking" on page 1195 for a configuration example. Configuring OSPF and OSPFv3 1119 Default OSPF Values OSPF is globally enabled by default. To make it operational on the router, you must configure a router ID and enable OSPF on at least one interface. Table 35-1 shows the global default values for OSPF and OSPFv3. Table 35-1. OSPF/OSPFv3 Global Defaults Parameter Default Value Router ID None Admin Mode Enabled RFC 1583 Compatibility Enabled (OSPFv2 only) ABR Status Enabled Opaque LSA Status Enabled (OSPFv2 only) Exit Overflow Interval Not configured SPF Delay Time 5 (OSPFv2 only) SPF Hold Time 10 (OSPFv2 only) External LSDB Limit None Default Metric Not configured Maximum Paths 4 AutoCost Reference Bandwidth 100 Mbps Default Passive Setting Disabled Default Information Originate Disabled Non-Stop Forwarding (NSF) Support Disabled 1120 Configuring OSPF and OSPFv3 Table 35-2 shows the per-interface default values for OSPF and OSPFv3. Table 35-2. OSPF Per-Interface Defaults Parameter Default Value Admin Mode Disabled Advertise Secondaries Enabled (OSPFv2 only) Router Priority 1 Retransmit Interval 5 seconds Hello Interval 10 seconds Dead Interval 40 seconds LSA Ack Interval 1 second Interface Delay Interval 1 second MTU Ignore Disabled Passive Mode Disabled Network Type Broadcast Authentication Type None (OSPFv2 only) Metric Cost Not configured Configuring OSPF and OSPFv3 1121 Configuring OSPF Features (Web) This section provides information about the OpenManage Switch Administrator pages for configuring and monitoring OSPF features on a Dell Networking N2000, N3000, and N4000 series switches. For details about the fields on a page, click at the top of the page. OSPF Configuration Use the Configuration page to enable OSPF on a router and to configure the related OSPF settings. To display the page, click Routing → OSPF → Configuration in the navigation panel. Figure 35-1. OSPF Configuration 1122 Configuring OSPF and OSPFv3 OSPF Area Configuration The Area Configuration page lets you create a Stub area configuration and NSSA once you’ve enabled OSPF on an interface through Routing → OSPF → Interface Configuration. At least one router must have OSPF enabled for this web page to display. To display the page, click Routing → OSPF → Area Configuration in the navigation panel. If a Stub Area has been created, the fields in the Stub Area Information are available. If a NSSA has been created, the fields in the NSSA Area Information are available. Figure 35-2. OSPF Area Configuration Configuring OSPF and OSPFv3 1123 Configuring an OSPF Stub Area To configure the area as an OSPF stub area, click Create Stub Area. The pages refreshes, and displays additional fields that are specific to the stub area. Figure 35-3. OSPF Stub Area Configuration Use the Delete Stub Area button to remove the stub area. 1124 Configuring OSPF and OSPFv3 Configuring an OSPF Not-So-Stubby Area To configure the area as an OSPF not-so-stubby area (NSSA), click NSSA Create. The pages refreshes, and displays additional fields that are specific to the NSSA. Figure 35-4. OSPF NSSA Configuration Use the NSSA Delete button to remove the NSSA area. Configuring OSPF and OSPFv3 1125 OSPF Stub Area Summary The Stub Area Summary page displays OSPF stub area detail. To display the page, click Routing → OSPF → Stub Area Summary in the navigation panel. Figure 35-5. OSPF Stub Area Summary 1126 Configuring OSPF and OSPFv3 OSPF Area Range Configuration Use the Area Range Configuration page to configure and display an area range for a specified NSSA. To display the page, click Routing → OSPF → Area Range Configuration in the navigation panel. Figure 35-6. OSPF Area Range Configuration Configuring OSPF and OSPFv3 1127 OSPF Interface Statistics Use the Interface Statistics page to display statistics for the selected interface. The information is displayed only if OSPF is enabled. To display the page, click Routing → OSPF → Interface Statistics in the navigation panel. Figure 35-7. OSPF Interface Statistics 1128 Configuring OSPF and OSPFv3 OSPF Interface Configuration Use the Interface Configuration page to configure an OSPF interface. To display the page, click Routing → OSPF → Interface Configuration in the navigation panel. Figure 35-8. OSPF Interface Configuration Configuring OSPF and OSPFv3 1129 OSPF Neighbor Table Use the Neighbor Table page to display the OSPF neighbor table list. When a particular neighbor ID is specified, detailed information about a neighbor is given. The information below is only displayed if OSPF is enabled. To display the page, click Routing → OSPF → Neighbor Table in the navigation panel. Figure 35-9. OSPF Neighbor Table 1130 Configuring OSPF and OSPFv3 OSPF Neighbor Configuration Use the Neighbor Configuration page to display the OSPF neighbor configuration for a selected neighbor ID. When a particular neighbor ID is specified, detailed information about a neighbor is given. The information below is only displayed if OSPF is enabled and the interface has a neighbor. The IP address is the IP address of the neighbor. To display the page, click Routing → OSPF → Neighbor Configuration in the navigation panel. Figure 35-10. OSPF Neighbor Configuration Configuring OSPF and OSPFv3 1131 OSPF Link State Database Use the Link State Database page to display OSPF link state, external LSDB table, and AS opaque LSDB table information. To display the page, click Routing → OSPF → Link State Database in the navigation panel. Figure 35-11. OSPF Link State Database OSPF Virtual Link Configuration Use the Virtual Link Configuration page to create or configure virtual interface information for a specific area and neighbor. A valid OSPF area must be configured before this page can be displayed. To display the page, click Routing → OSPF → Virtual Link Configuration in the navigation panel. 1132 Configuring OSPF and OSPFv3 Figure 35-12. OSPF Virtual Link Creation After you create a virtual link, additional fields display, as the Figure 35-13 shows. Figure 35-13. OSPF Virtual Link Configuration Configuring OSPF and OSPFv3 1133 OSPF Virtual Link Summary Use the Virtual Link Summary page to display all of the configured virtual links. To display the page, click Routing → OSPF → Virtual Link Summary in the navigation panel. Figure 35-14. 1134 OSPF Virtual Link Summary Configuring OSPF and OSPFv3 OSPF Route Redistribution Configuration Use the Route Redistribution Configuration page to configure redistribution in OSPF for routes learned through various protocols. You can choose to redistribute routes learned from all available protocols or from selected ones. To display the page, click Routing → OSPF → Route Redistribution Configuration in the navigation panel. Figure 35-15. OSPF Route Redistribution Configuration Configuring OSPF and OSPFv3 1135 OSPF Route Redistribution Summary Use the Route Redistribution Summary page to display OSPF Route Redistribution configurations. To display the page, click Routing → OSPF → Route Redistribution Summary in the navigation panel. Figure 35-16. 1136 OSPF Route Redistribution Summary Configuring OSPF and OSPFv3 NSF OSPF Configuration Use the NSF OSPF Configuration page to configure the non-stop forwarding (NSF) support mode and to view NSF summary information for the OSPF feature. NSF is a feature used in switch stacks to maintain switching and routing functions in the event of a stack unit failure. For information about NSF, see "What is Nonstop Forwarding?" on page 178 in the Managing a Switch Stack chapter. To display the page, click Routing → OSPF → NSF OSPF Configuration in the navigation panel. Figure 35-17. NSF OSPF Configuration Configuring OSPF and OSPFv3 1137 Configuring OSPFv3 Features (Web) This section provides information about the OpenManage Switch Administrator pages for configuring and monitoring OSPFv3 features on a Dell Networking N2000, N3000, and N4000 series switches. For details about the fields on a page, click at the top of the page. OSPFv3 Configuration Use the Configuration page to activate and configure OSPFv3 for a switch. To display the page, click IPv6 → OSPFv3 → Configuration in the navigation panel. Figure 35-18. 1138 OSPFv3 Configuration Configuring OSPF and OSPFv3 OSPFv3 Area Configuration Use the Area Configuration page to create and configure an OSPFv3 area. To display the page, click IPv6 → OSPFv3 → Area Configuration in the navigation panel. Figure 35-19. OSPFv3 Area Configuration Configuring OSPF and OSPFv3 1139 Configuring an OSPFv3 Stub Area To configure the area as an OSPFv3 stub area, click Create Stub Area. The pages refreshes, and displays additional fields that are specific to the stub area. Figure 35-20. OSPFv3 Stub Area Configuration Use the Delete Stub Area button to remove the stub area. 1140 Configuring OSPF and OSPFv3 Configuring an OSPFv3 Not-So-Stubby Area To configure the area as an OSPFv3 not-so-stubby area (NSSA), click Create NSSA. The pages refreshes, and displays additional fields that are specific to the NSSA. Figure 35-21. OSPFv3 NSSA Configuration Use the Delete NSSA button to remove the NSSA area. Configuring OSPF and OSPFv3 1141 OSPFv3 Stub Area Summary Use the Stub Area Summary page to display OSPFv3 stub area detail. To display the page, click IPv6 → OSPFv3 → Stub Area Summary in the navigation panel. Figure 35-22. 1142 OSPFv3 Stub Area Summary Configuring OSPF and OSPFv3 OSPFv3 Area Range Configuration Use the Area Range Configuration page to configure OSPFv3 area ranges. To display the page, click IPv6 → OSPFv3 → Area Range Configuration in the navigation panel. Figure 35-23. OSPFv3 Area Range Configuration Configuring OSPF and OSPFv3 1143 OSPFv3 Interface Configuration Use the Interface Configuration page to create and configure OSPFv3 interfaces. To display the page, click IPv6 → OSPFv3 → Interface Configuration in the navigation panel. Figure 35-24. 1144 OSPFv3 Interface Configuration Configuring OSPF and OSPFv3 OSPFv3 Interface Statistics Use the Interface Statistics page to display OSPFv3 interface statistics. Information is only displayed if OSPF is enabled. To display the page, click IPv6 → OSPFv3 → Interface Statistics in the navigation panel. Figure 35-25. OSPFv3 Interface Statistics Configuring OSPF and OSPFv3 1145 OSPFv3 Neighbors Use the Neighbors page to display the OSPF neighbor configuration for a selected neighbor ID. When a particular neighbor ID is specified, detailed information about that neighbor is given. Neighbor information only displays if OSPF is enabled and the interface has a neighbor. The IP address is the IP address of the neighbor. To display the page, click IPv6 → OSPFv3 → Neighbors in the navigation panel. Figure 35-26. 1146 OSPFv3 Neighbors Configuring OSPF and OSPFv3 OSPFv3 Neighbor Table Use the Neighbor Table page to display the OSPF neighbor table list. When a particular neighbor ID is specified, detailed information about a neighbor is given. The neighbor table is only displayed if OSPF is enabled. To display the page, click IPv6 → OSPFv3 → Neighbor Table in the navigation panel. Figure 35-27. OSPFv3 Neighbor Table Configuring OSPF and OSPFv3 1147 OSPFv3 Link State Database Use the Link State Database page to display the link state and external LSA databases. The OSPFv3 Link State Database page has been updated to display external LSDB table information in addition to OSPFv3 link state information. To display the page, click IPv6 → OSPFv3 → Link State Database in the navigation panel. Figure 35-28. 1148 OSPFv3 Link State Database Configuring OSPF and OSPFv3 OSPFv3 Virtual Link Configuration Use the Virtual Link Configuration page to define a new or configure an existing virtual link. To display this page, a valid OSPFv3 area must be defined through the OSPFv3 Area Configuration page. To display the page, click IPv6 → OSPFv3 → Virtual Link Configuration in the navigation panel. Figure 35-29. OSPFv3 Virtual Link Configuration Configuring OSPF and OSPFv3 1149 After you create a virtual link, additional fields display, as the Figure 35-30 shows. Figure 35-30. 1150 OSPFv3 Virtual Link Configuration Configuring OSPF and OSPFv3 OSPFv3 Virtual Link Summary Use the Virtual Link Summary page to display virtual link data by Area ID and Neighbor Router ID. To display the page, click IPv6 → OSPFv3 → Virtual Link Summary in the navigation panel. Figure 35-31. OSPFv3 Virtual Link Summary Configuring OSPF and OSPFv3 1151 OSPFv3 Route Redistribution Configuration Use the Route Redistribution Configuration page to configure route redistribution. To display the page, click IPv6 → OSPFv3 → Route Redistribution Configuration in the navigation panel. Figure 35-32. 1152 OSPFv3 Route Redistribution Configuration Configuring OSPF and OSPFv3 OSPFv3 Route Redistribution Summary Use the Route Redistribution Summary page to display route redistribution settings by source. To display the page, click IPv6 → OSPFv3 → Route Redistribution Summary in the navigation panel. Figure 35-33. OSPFv3 Route Redistribution Summary Configuring OSPF and OSPFv3 1153 NSF OSPFv3 Configuration Use the NSF OSPFv3 Configuration page to configure the non-stop forwarding (NSF) support mode and to view NSF summary information for the OSPFv3 feature. NSF is a feature used in switch stacks to maintain switching and routing functions in the event of a stack unit failure. For information about NSF, see "What is Nonstop Forwarding?" on page 178 in the Managing a Switch Stack chapter. To display the page, click Routing → OSPFv3 → NSF OSPFv3 Configuration in the navigation panel. Figure 35-34. 1154 NSF OSPFv3 Configuration Configuring OSPF and OSPFv3 Configuring OSPF Features (CLI) This section provides information about the commands you use to configure and view OSPF settings on the switch. This section does not describe all available show commands. For more information about all available OSPF commands, see the Dell Networking N2000, N3000, and N4000 Series Switches CLI Reference Guide at support.dell.com/manuals. Configuring Global OSPF Settings Beginning in Privileged EXEC mode, use the following commands to configure various global OSPF settings for the switch. Command Purpose configure Enter global configuration mode. router ospf Enter OSPF configuration mode. router-id ip-address Set the 4-digit dotted-decimal number that uniquely identifies the router. auto-cost referencebandwidth ref_bw Set the reference bandwidth used in the formula to compute link cost for an interface: link cost = ref_bw÷interface bandwidth The ref_bw variable is the reference bandwidth in Mbps (Range: 1–4294967). capability opaque Allow OSPF to store and flood opaque LSAs. An opaque LSA is used for flooding user defined information within an OSPF router domain. compatible rfc1583 (Optional) Enable compatibility with RFC 1583. If all OSPF routers in the routing domain are capable of operating according to RFC 2328, OSPF 1583 compatibility mode should be disabled. Configuring OSPF and OSPFv3 1155 Command Purpose Control the advertisement of default routes. default-information originate [always] • always — Normally, OSPF originates a default route only [metric metric-value] if a default route is redistributed into OSPF (and default[metric-type type-value] information originate is configured). When the always option is configured, OSPF originates a default route, even if no default route is redistributed. • metric-value — The metric (or preference) value of the default route. (Range: 1–16777214) • type-value — The value is either 1 or 2: External type-1 route or External type-2 route. default-metric metric- value Set a default for the metric of distributed routes (Range: 1–16777214). distance ospf {external | Set the preference values of OSPF route types in the inter-area | intra-area } router. distance The range for the distance variable is 1–255. Lower route preference values are preferred when determining the best route. enable Enable OSPF. exit-overflow-interval Specify the exit overflow interval for OSPF as defined in RFC 1765. seconds The interval is the number of seconds after entering overflow state that a router will wait before attempting to leave the overflow state. (Range: 0–2147483647) external-lsdb-limit limit Configure the external LSDB limit for OSPF as defined in RFC 1765. If the value is –1, then there is no limit. The limit variable is the maximum number of non-default AS external-LSAs allowed in the router's link-state database. (Range: 1 to 2147483647) maximum-paths integer Set the number of paths that OSPF can report for a given destination (Range: 1–4). 1156 Configuring OSPF and OSPFv3 Command Purpose passive-interface default Configure OSPF interfaces as passive by default. This command overrides any interface-level passive mode settings.OSPF does not form adjacencies on passive interfaces but does advertise attached networks as stub networks. timers spf delay-time hold-time Specify the SPF delay and hold time. • delay-time — SPF delay time. (Range: 0–65535 seconds) • hold-time — SPF hold time. (Range: 0–65535 seconds) exit Exit to Global Configuration mode. exit Exit to Privileged EXEC mode. show ip ospf View OSPF global configuration and status. show ip ospf statistics View OSPF routing table calculation statistics. clear ip ospf Reset specific OSPF states. If no parameters are specified, [{configuration | OSPF is disabled and then re-enabled. redistribution | counters | neighbor [interface vlan vlan-id [neighbor-id]]}] Configuring OSPF and OSPFv3 1157 Configuring OSPF Interface Settings Beginning in Privileged EXEC mode, use the following commands to configure per-interface OSPF settings. Command Purpose configure Enter global configuration mode. interface vlan vlan-id Enter Interface Configuration mode for the specified VLAN. ip ospf area area-id [secondaries none] Enables OSPFv2 on the interface and sets the area ID of an interface. This command supersedes the effects of network area command. The area-id variable is the ID of the area (Range: IP address or decimal from 0 –4294967295) Use the secondaries none keyword to prevent the interface from advertising its secondary addresses into the OSPFv2 domain. ip ospf priority number- Set the OSPF priority for the interface. The number-value value variable specifies the priority of an interface (Range: 0 to 255). The default priority is 1, which is the highest router priority. A value of 0 indicates that the router is not eligible to become the designated router on this network. ip ospf retransmitinterval seconds Set the OSPF retransmit interval for the interface. The seconds variable is the number of seconds between link-state advertisements for adjacencies belonging to this router interface. This value is also used when retransmitting database descriptions and link-state request packets. Valid values range from 0 to 3600 seconds (1 hour). ip ospf hello-interval seconds Set the OSPF hello interval for the interface. This parameter must be the same for all routers attached to a network. The seconds variable indicates the number of seconds to wait before sending Hello packets from the interface. (Range: 1–65535). 1158 Configuring OSPF and OSPFv3 Command Purpose ip ospf dead-interval Set the OSPF dead interval for the interface. seconds The seconds variable indicates the number of seconds a router waits to see a neighbor router's Hello packets before declaring that the router is down (Range: 1–65535). This parameter must be the same for all routers attached to a network. This value should be some multiple of the Hello Interval. ip ospf transmit-delay seconds Set the OSPF Transit Delay for the interface. The seconds variable sets the estimated number of seconds it takes to transmit a link state update packet over this interface. (Range: 1–3600 seconds) ip ospf mtu-ignore Disable OSPF MTU mismatch detection on the received database description. ip ospf network {broadcast | point-topoint} Set the OSPF network type on the interface to broadcast or point-to-point. OSPF selects a designated router and originates network LSAs only for broadcast networks. No more than two OSPF routers may be present on a pointto-point link. ip ospf authentication {none | {simple key} | {encrypt key key-id}} Set the OSPF Authentication Type and Key for the specified interface. • encrypt — MD5 encrypted authentication key. • key — Authentication key for the specified interface. (Range: 8 bytes or less if the authentication type is simple and 16 bytes or less if the type is encrypt.) • key-id — Authentication key identifier for the authentication type encrypt. (Range: 0–25) ip ospf cost interface- cost bandwidth bw Set the metric cost of the interface. The interface-cost variable specifies the cost (link-state metric) of the OSPF interface. (Range: 1–65535) Set the interface bandwidth used in the formula to compute link cost for an interface: link cost = ref_bw÷interface bandwidth The bw variable is the interface bandwidth (Range: 1–10000000 Kbps). Configuring OSPF and OSPFv3 1159 Command Purpose exit Exit to Global Configuration Mode router ospf Enter OSPF configuration mode. passive-interface vlan Make an interface passive to prevent OSPF from forming an adjacency on an interface. OSPF advertises networks attached to passive interfaces as stub networks. vlan-id network ip-address Enable OSPFv2 on interfaces whose primary IP address wildcard-mask area area- matches this command, and make the interface a member id of the specified area. • ip-address — Base IPv4 address of the network area. • wildcard-mask — The network mask indicating the subnet. • area-id — The ID of the area (Range: IP address or decimal from 0–4294967295). exit Exit to Global Config mode. exit Exit to Privileged EXEC mode. show ip ospf interface [vlan vlan-id] View summary information for all OSPF interfaces configured on the switch or for the specified routing interface. show ip ospf interface stats vlan vlan-id View per-interface OSPF statistics. Configuring Stub Areas and NSSAs Beginning in Privileged EXEC mode, use the following commands to configure OSPF stub areas and NSSAs. Command Purpose configure Enter global configuration mode. router ospf Enter OSPF configuration mode. area area-id stub Create a stub area for the specified area ID. area area-id stub nosummary Prevent Summary LSAs from being advertised into the stub area. 1160 Configuring OSPF and OSPFv3 Command Purpose area area-id default-cost integer Configure the metric value (default cost) for the type 3 summary LSA sent into the stub area. Range: 1–16777215) area area-id nssa Create an NSSA for the specified area ID. area area-id nssa nosummary Configure the NSSA so that summary LSAs are not advertised into the NSSA. area area-id nssa Configure the translator role of the NSSA. translator-role {always | • always — The router assumes the role of the translator candidate} when it becomes a border router. • candidate — The router can participate in the translator election process when it attains border router status. area area-id nssa translator-stab-intv Configure the translator stability interval of the NSSA. area area-id nssa defaultinformation-originate [metric metric-value] [metric-type metric-typevalue] Configure the metric value and type for the default route advertised into the NSSA. The metric type can be comparable (nssa-external 1) or non-comparable (nssaexternal 2). area area-id nssa no-redistribution Prevent learned external routes from being redistributed to the NSSA. exit Exit to Global Config mode. exit Exit to Privileged EXEC mode. integer The integer variable is the period of time that an elected translator continues to perform its duties after it determines that its translator status has been deposed by another router. (Range: 0–3600) show ip ospf area area-id View the configuration and status of an OSPF area. Configuring OSPF and OSPFv3 1161 Configuring Virtual Links Beginning in Privileged EXEC mode, use the following commands to configure OSPF Virtual Links. Command Purpose configure Enter global configuration mode. router ospf Enter OSPF configuration mode. area area-id virtual-link Create the OSPF virtual interface for the specified areaid and neighbor router. The neighbor-id variable is the IP address of the neighboring router. area area-id virtual-link router-id [authentication [message-digest | null]] [[authentication-key key] | [message-digest-key keyid md5 key]] Create the OSPF virtual interface for the specified areaid and neighbor router. neighbor-id Use the optional parameters to configure authentication for the virtual link. If the area has not been previously created, it is created by this command. If the area already exists, the virtual-link information is added or modified. • authentication—Specifies authentication type. • message-digest—Specifies that message-digest authentication is used. • null—No authentication is used. Overrides password or message-digest authentication if configured for the area. • md5—Use MD5 Encryption for an OSPF Virtual Link • key—Authentication key for the specified interface. (Range: 8 bytes or less if the authentication type is simple and 16 bytes or less if the type is encrypt.) • key-id—Authentication key identifier for the authentication type encrypt. (Range: 0-255) area area-id virtual-link neighbor-id retransmitinterval seconds 1162 Set the OSPF retransmit interval for the virtual link interface. The seconds variable is the number of seconds to wait between retransmitting LSAs if no acknowledgement is received. (Range: 0–3600) Configuring OSPF and OSPFv3 Command Purpose area area-id virtual-link Set the OSPF hello interval for the virtual link. neighbor-id hello-interval The seconds variable indicates the number of seconds to seconds wait before sending Hello packets from the virtual interface. (Range: 1–65535). Set the OSPF dead interval for the virtual link. area area-id virtual-link neighbor-id dead-interval The seconds variable indicates the number of seconds to seconds wait before the virtual interface is assumed to be dead. (Range: 1–65535) area area-id virtual-link neighbor-id transmitdelay seconds Set the OSPF Transit Delay for the interface. The seconds variable is the number of seconds to increment the age of the LSA before sending, based on the estimated time it takes to transmit from the interface. (Range: 0–3600) exit Exit to Global Config mode. exit Exit to Privileged EXEC mode. show ip ospf virtual-link brief View summary information about all virtual links configured on the switch. Configuring OSPF and OSPFv3 1163 Configuring OSPF Area Range Settings Beginning in Privileged EXEC mode, use the following commands to configure an OSPF area range. Command Purpose configure Enter global configuration mode. router ospf Enter OSPF configuration mode. area area-id range Configure a summary prefix for routes learned in a given area. ip-address mask {summarylink | nssaexternallink} [advertise |not-advertise] • area-id — Identifies the OSPF NSSA to configure. (Range: IP address or decimal from 0–4294967295) • ip-address — IP address. • subnet-mask — Subnet mask associated with IP address. • summarylink — Specifies a summary link LSDB type. • nssaexternallink — Specifies an NSSA external link LSDB type. • advertise — Advertisement of the area range. • not-advertise — Suppresses advertisement of the area range. exit Exit to Global Config mode. exit Exit to Privileged EXEC mode. show ip ospf range View information about the area ranges for the specified area-id. area-id Configuring OSPF Route Redistribution Settings Beginning in Privileged EXEC mode, use the following commands to configure OSPF route redistribution settings. Command Purpose configure Enter global configuration mode. router ospf Enter OSPF configuration mode. 1164 Configuring OSPF and OSPFv3 Command Purpose distribute-list Specify the access list to filter routes received from the static | connected} switch. For information about the commands you use to configure ACLs, see "Configuring ACLs (CLI)" on page 612. accesslistname out {rip | source protocol. The ACL must already exist on the • accesslistname — The name used to identify an existing ACL. • rip — Apply the specified access list when RIP is the source protocol. • static — Apply the specified access list when packets come through the static route. • connected — Apply the specified access list when packets come from a directly connected route. redistribute {rip | static | Configure OSPF to allow redistribution of routes from the specified source protocol/routers. connected} [metric integer] [metric-type {1 | • rip — Specifies RIP as the source protocol. 2}] [tag integer] [subnets] • static — Specifies that the source is a static route. • connected — Specifies that the source is a directly connected route. • metric — Specifies the metric to use when redistributing the route. (Range: 0–16777214) • metric-type 1 — Type 1 external route. • metric-type 2 — Type 2 external route. • tag — Value attached to each external route. (Range: 0–4294967295) • subnets—Unless this keyword is configured, OSPF distributes only class A, class B, and class C prefixes. exit Exit to Global Config mode. exit Exit to Privileged EXEC mode. show ip ospf View OSPF configuration and status information, including route distribution information. Configuring OSPF and OSPFv3 1165 Configuring NSF Settings for OSPF Beginning in Privileged EXEC mode, use the following commands to configure the non-stop forwarding settings for OSPF. Command Purpose configure Enter global configuration mode. router ospf Enter OSPF configuration mode. nsf [ietf ] helper strict-lsa- Require that an OSPF helpful neighbor exit helper mode checking whenever a topology change occurs. Use the ietf keyword to distinguish the IETF standard implementation of graceful restart from other implementations. nsf [ietf ] restart-interval Configure the length of the grace period on the restarting router. seconds The seconds keyword is the number of seconds that the restarting router asks its neighbors to wait before exiting helper mode. The restarting router includes the restart interval in its grace LSAs (range 1–1800 seconds) nsf helper [planned-only] Allow OSPF to act as a helpful neighbor for a restarting router. Include the planned-only keyword to indicate that OSPF should only help a restarting router performing a planned restart. nsf [ietf] [planned-only] Enable a graceful restart of OSPF. • ietf — This keyword is used to distinguish the IETF standard implementation of graceful restart from other implementations. Since the IETF implementation is the only one supported, this keyword is optional. • planned-only — This keyword indicates that OSPF should only perform a graceful restart when the restart is planned (i.e., when the restart is a result of the initiate failover command). 1166 Configuring OSPF and OSPFv3 Configuring OSPFv3 Features (CLI) This section provides information about the commands you use to configure OSPFv3 settings on the switch. For more information about the commands and about additional show commands, see the Dell Networking N2000, N3000, and N4000 Series Switches CLI Reference Guide at support.dell.com/manuals. Configuring Global OSPFv3 Settings Beginning in Privileged EXEC mode, use the following commands to configure various global OSPFv3 settings for the switch. Command Purpose configure Enter global configuration mode. ipv6 router ospf Enter OSPFv3 configuration mode. router-id ip-address Set the 4-digit dotted-decimal number that uniquely identifies the router. auto-cost referencebandwidth ref_bw Set the reference bandwidth used in the formula to compute link cost for an interface: link cost = ref_bw÷interface bandwidth The ref_bw variable is the reference bandwidth in Mbps (Range: 1–4294967). Control the advertisement of default routes. default-information originate [always] • always — Normally, OSPFv3 originates a default route [metric metric-value] only if a default route is redistributed into OSPFv3 (and [metric-type type-value] default-information originate is configured). When the always option is configured, OSPFv3 originates a default route, even if no default route is redistributed. • metric-value — The metric (or preference) value of the default route. (Range: 1–16777214) • type-value — The value is either 1 or 2: External type-1 route or External type-2 route. default-metric metric- value Set a default for the metric of distributed routes. (Range: 1–16777214). Configuring OSPF and OSPFv3 1167 Command Purpose distance ospf {external | Set the preference values of OSPFv3 route types in the inter-area | intra-area } router. distance The range for the distance variable is 1–255. Lower route preference values are preferred when determining the best route. enable Enable OSPFv3. exit-overflow-interval Specify the exit overflow interval for OSPFv3 as defined in RFC 1765. seconds The interval is the number of seconds after entering overflow state that a router will wait before attempting to leave the overflow state. (Range: 0–2147483647) external-lsdb-limit limit Configure the external LSDB limit for OSPFv3 as defined in RFC 1765. If the value is -1, then there is no limit. The limit variable is the maximum number of non-default AS external-LSAs allowed in the router's link-state database. (Range: –1 to 2147483647) maximum-paths maxpaths Set the number of paths that OSPFv3 can report for a given destination. (Range: 1–4.) passive-interface default Configure OSPFv3 interfaces as passive by default. This command overrides any interface-level passive mode settings. OSPFv3 does not form adjacencies on passive interfaces but does advertise attached networks as stub networks. exit Exit to Global Configuration mode. exit Exit to Privileged EXEC mode. show ipv6 ospf View OSPFv3 global configuration and status. Reset specific OSPFv3 states. If no parameters are clear ipv6 ospf specified, OSPFv3 is disabled and then re-enabled. [{configuration | redistribution | counters | neighbor [interface vlan vlan-id [neighbor-id]]}] 1168 Configuring OSPF and OSPFv3 Configuring OSPFv3 Interface Settings Beginning in Privileged EXEC mode, use the following commands to configure per-interface OSPFv3 settings. Command Purpose configure Enter global configuration mode. interface vlan vlan-id Enter Interface Configuration mode for the specified VLAN. ipv6 ospf areaid area-id Enables OSPFv3 on the interface and sets the area ID of an interface. This command supersedes the effects of network area command. The area-id variable is the ID of the area (Range: IP address or decimal from 0 –4294967295) ipv6 ospf priority number-value Set the OSPFv3 priority for the interface. The numbervalue variable specifies the priority of an interface (Range: 0 to 255). The default priority is 1, which is the highest router priority. A value of 0 indicates that the router is not eligible to become the designated router on this network. ipv6 ospf retransmitinterval seconds Set the OSPFv3 retransmit interval for the interface. The seconds variable is the number of seconds between link-state advertisements for adjacencies belonging to this router interface. This value is also used when retransmitting database descriptions and link-state request packets. Valid values range from 0 to 3600 seconds (1 hour). ipv6 ospf hello-interval seconds Set the OSPFv3 hello interval for the interface. This parameter must be the same for all routers attached to a network. The seconds variable indicates the number of seconds to wait before sending Hello packets from the interface. (Range: 1–65535). Configuring OSPF and OSPFv3 1169 Command Purpose ipv6 ospf dead-interval Set the OSPFv3 dead interval for the interface. seconds The seconds variable indicates the number of seconds a router waits to see a neighbor router's Hello packets before declaring that the router is down (Range: 1–65535). This parameter must be the same for all routers attached to a network. This value should be some multiple of the Hello Interval. ipv6 ospf transmit-delay Set the OSPFv3 Transit Delay for the interface. seconds The seconds variable sets the estimated number of seconds it takes to transmit a link state update packet over this interface. (Range: 1–3600 seconds) ip ospf mtu-ignore Disable OSPFv3 MTU mismatch detection on received database description packets. ipv6 ospf network {broadcast | point-topoint } Set the OSPFv3 network type on the interface to broadcast or point-to-point. OSPFv3 selects a designated router and originates network LSAs only for broadcast networks. No more than two OSPFv3 routers may be present on a point-to-point link. ipv6 ospf cost interface- Set the metric cost of the interface. cost The interface-cost variable specifies the cost (link-state metric) of the OSPFv3 interface. (Range: 1–65535) bandwidth bw Set the interface bandwidth used in the formula to compute link cost for an interface: link cost = ref_bw÷interface bandwidth The bw variable is the interface bandwidth (Range: 1–10000000 Kbps). exit Exit to Global Configuration Mode ipv6 router ospf Enter OSPFv3 configuration mode. vlan-id | tunnel tunnelid} passive-interface {vlan Make an interface passive to prevent OSPFv3 from forming an adjacency on an interface. OSPFv3 advertises networks attached to passive interfaces as stub networks. exit Exit to Global Config mode. exit Exit to Privileged EXEC mode. 1170 Configuring OSPF and OSPFv3 Command Purpose show ipv6 ospf interface View summary information for all OSPFv3 interfaces [interface-type interface- configured on the switch or for the specified routing number] interface. show ipv6 ospf interface View per-interface OSPFv3 statistics. stats interface-type interface-number Configuring Stub Areas and NSSAs Beginning in Privileged EXEC mode, use the following commands to configure OSPFv3 stub areas and NSSAs. Command Purpose configure Enter global configuration mode. ipv6 router ospf Enter OSPFv3 configuration mode. area area-id stub Create a stub area for the specified area ID. area area-id stub nosummary Prevent Summary LSAs from being advertised into the stub area. area area-id default-cost Configure the metric value (default cost) for the type 3 summary LSA sent into the stub area. Range: 1–16777215) cost Configuring OSPF and OSPFv3 1171 Command Purpose area area-id nssa [noCreate and configure an NSSA for the specified area ID. redistribution] [default- • metric-value—Specifies the metric of the default route information-originate advertised to the NSSA. (Range: 1–16777214) [metric metric-value] [metric-type metric-type- • metric-type-value—The metric type can be one of the following : value]] [no-summary] [translator-role role] • A metric type of nssa-external 1 (comparable) [translator-stab-intv • A metric type of nssa-external 2 (non-comparable) interval] • no-summary—Summary LSAs are not advertised into the NSSA • role—The translator role where role is one of the following : • always—The router assumes the role of the translator when it becomes a border router. • candidate—The router to participate in the translator election process when it attains border router status. • interval—The period of time that an elected translator continues to perform its duties after it determines that its translator status has been deposed by another router. (Range: 0–3600) area area-id nssa no-redistribution Prevent learned external routes from being redistributed to the NSSA. exit Exit to Global Config mode. exit Exit to Privileged EXEC mode. show ipv6 ospf area area- Show configuration and status of an OSPF area. id 1172 Configuring OSPF and OSPFv3 Configuring Virtual Links Beginning in Privileged EXEC mode, use the following commands to configure OSPFv3 Virtual Links. Command Purpose configure Enter global configuration mode. ipv6 router ospf Enter OSPFv3 configuration mode. area area-id virtual-link Create the OSPFv3 virtual interface for the specified area-id and neighbor router. The neighbor-id variable is the IP address of the neighboring router. area area-id virtual-link neighbor-id retransmitinterval seconds Set the OSPFv3 retransmit interval for the virtual link interface. neighbor-id The seconds variable is the number of seconds to wait between retransmitting LSAs if no acknowledgement is received. (Range: 0–3600) area area-id virtual-link Set the OSPFv3 hello interval for the virtual link. neighbor-id hello-interval The seconds variable indicates the number of seconds to seconds wait before sending Hello packets from the virtual interface. (Range: 1–65535). Set the OSPFv3 dead interval for the virtual link. area area-id virtual-link neighbor-id dead-interval The seconds variable indicates the number of seconds to seconds wait before the virtual interface is assumed to be dead. (Range: 1–65535) area area-id virtual-link neighbor-id transmitdelay seconds Set the OSPFv3 Transit Delay for the interface. The seconds variable is the number of seconds to increment the age of the LSA before sending, based on the estimated time it takes to transmit from the interface. (Range: 0–3600) exit Exit to Global Config mode. exit Exit to Privileged EXEC mode. show ipv6 ospf virtuallink brief View summary information about all virtual links configured on the switch. Configuring OSPF and OSPFv3 1173 Configuring an OSPFv3 Area Range Beginning in Privileged EXEC mode, use the following commands to configure an OSPFv3 area range. Command Purpose configure Enter global configuration mode. ipv6 router ospf Enter OSPFv3 configuration mode. area area-id range ipv6- Configure a summary prefix for routes learned in a given area. prefix/prefix-length {summarylink | • area-id — Identifies the OSPFv3 NSSA to configure. nssaexternallink} (Range: IP address or decimal from 0–4294967295) [advertise |not-advertise] • ipv6-prefix/prefix-length — IPv6 address and prefix length. • summarylink — Specifies a summary link LSDB type. • nssaexternallink — Specifies an NSSA external link LSDB type. • advertise — Advertisement of the area range. • not-advertise — Suppresses advertisement of the area range. exit Exit to Global Config mode. exit Exit to Privileged EXEC mode. show ipv6 ospf range area- View information about the area ranges for the specified area-id. id 1174 Configuring OSPF and OSPFv3 Configuring OSPFv3 Route Redistribution Settings Beginning in Privileged EXEC mode, use the following commands to configure OSPFv3 route redistribution settings. Command Purpose configure Enter global configuration mode. ipv6 router ospf Enter OSPFv3 configuration mode. redistribute {static | Configure OSPFv3 to allow redistribution of routes from connected} [metric the specified source protocol/routers. metric] [metric-type {1 | • static — Specifies that the source is a static route. 2}] [tag tag] • connected — Specifies that the source is a directly connected route. • metric — Specifies the metric to use when redistributing the route. (Range: 0–16777214) • metric-type 1 — Type 1 external route. • metric-type 2 — Type 2 external route. • tag — Value attached to each external route, which might be used to communicate information between ASBRs. (Range: 0–4294967295) exit Exit to Global Config mode. exit Exit to Privileged EXEC mode. show ipv6 ospf View OSPFv3 configuration and status information, including information about redistributed routes. Configuring OSPF and OSPFv3 1175 Configuring NSF Settings for OSPFv3 Beginning in Privileged EXEC mode, use the following commands to configure the non-stop forwarding settings for OSPFv3. Command Purpose configure Enter global configuration mode. ipv6 router ospf Enter OSPFv3 configuration mode. nsf [ietf ] helper strict-lsa- Require that an OSPFv3 helpful neighbor exit helper checking mode whenever a topology change occurs. Use the ietf keyword to distinguish the IETF standard implementation of graceful restart from other implementations. nsf [ietf ] restart-interval Configure the length of the grace period on the restarting seconds router. The seconds keyword is the number of seconds that the restarting router asks its neighbors to wait before exiting helper mode. The restarting router includes the restart interval in its grace LSAs (range 1–1800 seconds) nsf helper [planned-only] Allow OSPFv3 to act as a helpful neighbor for a restarting router. Include the planned-only keyword to indicate that OSPFv3 should only help a restarting router performing a planned restart. nsf [ietf] [planned-only] Enable a graceful restart of OSPFv3. • ietf — This keyword is used to distinguish the IETF standard implementation of graceful restart from other implementations. Since the IETF implementation is the only one supported, this keyword is optional. • planned-only — This keyword indicates that OSPF should only perform a graceful restart when the restart is planned (i.e., when the restart is a result of the initiate failover command). 1176 Configuring OSPF and OSPFv3 OSPF Configuration Examples This section contains the following examples: • Configuring an OSPF Border Router and Setting Interface Costs • Configuring Stub and NSSA Areas for OSPF and OSPFv3 • Configuring a Virtual Link for OSPF and OSPFv3 Configuring an OSPF Border Router and Setting Interface Costs This example shows how to configure the Dell Networking switch as an OSPF border router. The commands in this example configure the areas and interfaces on Border Router A shown in Figure 35-35. Figure 35-35. OSPF Area Border Router Area 0 Backbone Area Internal Router VLAN 50 192.150.2.1 Border Router A VLAN 80 192.150.3.1 VLAN 70 192.150.2.2 Border Router B VLAN 90 192.150.4.1 Area 2 Area 3 Configuring OSPF and OSPFv3 1177 To Configure Border Router A: 1 Enable routing on the switch. console#configure console(config)#ip routing 2 Create VLANS 70, 80, and 90 and assign them to interfaces. console(config)#vlan 70,80,90 console(config-vlan70,80,90)#interface gi1/0/1 console(config-if-Gi1/0/1)#switchport access vlan 70 console(config-if-Gi1/0/1)#interface gi1/0/2 console(config-if-Gi1/0/2)#switchport access vlan 80 console(config-if-Gi1/0/1)#interface gi1/0/3 console(config-if-Gi1/0/2)#switchport access vlan 90 3 Assign IP addresses for VLANs 70, 80 and 90. console(config)#interface vlan 70 console(config-if-vlan70)#ip address 192.150.2.2 255.255.255.0 console(config-if-vlan70)#exit console(config)#interface vlan 80 console(config-if-vlan80)#ip address 192.150.3.1 255.255.255.0 console(config-if-vlan80)#exit console(config)#interface vlan 90 console(config-if-vlan90)#ip address 192.150.4.1 255.255.255.0 console(config-if-vlan90)#exit 4 Enable OSPF on the switch and specify a router ID. console(config)#router ospf console(config-router)#router-id 192.150.9.9 console(config-router)#exit 1178 Configuring OSPF and OSPFv3 5 Configure the OSPF area ID, priority, and cost for each interface. NOTE: OSPF is globally enabled by default. To make it operational on the router, you configure OSPF for particular interfaces and identify which area the interface is associated with. console(config)#interface vlan 70 console(config-if-vlan70)#ip ospf area 0.0.0.0 console(config-if-vlan70)#ip ospf priority 128 console(config-if-vlan70)#ip ospf cost 32 console(config-if-vlan70)#exit console(config)#interface vlan 80 console(config-if-vlan80)#ip ospf area 0.0.0.2 console(config-if-vlan80)#ip ospf priority 255 console(config-if-vlan80)#ip ospf cost 64 console(config-if-vlan80)#exit console(config)#interface vlan 90 console(config-if-vlan90)#ip ospf area 0.0.0.2 console(config-if-vlan90)#ip ospf priority 255 console(config-if-vlan90)#ip ospf cost 64 console(config-if-vlan90)#exit Configuring OSPF and OSPFv3 1179 Configuring Stub and NSSA Areas for OSPF and OSPFv3 In this example, Area 0 connects directly to two other areas: Area 1 is defined as a stub area and Area 2 is defined as an NSSA area. NOTE: OSPFv2 and OSPFv3 can operate concurrently on a network and on the same interfaces (although they do not interact). This example configures both protocols simultaneously. Figure 35-36 illustrates this example OSPF configuration. Figure 35-36. 1180 OSPF Configuration—Stub Area and NSSA Area Configuring OSPF and OSPFv3 Switch A is a backbone router. It links to an ASBR (not defined here) that routes traffic outside the AS. To configure Switch A: 1 Globally enable IPv6 and IPv4 routing: console#configure console(config)#ipv6 unicast-routing console(config)#ip routing 2 Create VLANs 6 and 12 and assign them to interfaces. console(config)#vlan 6,12 console(config-vlan6,12)#interface gi1/0/1 console(config-if-Gi1/0/1)#switchport access vlan 6 console(config-if-Gi1/0/1)#interface gi1/0/2 console(config-if-Gi1/0/2)#switchport access vlan 12 3 Configure IP and IPv6 addresses on VLAN routing interface 6. console(config-if)#interface vlan 6 console(config-if-vlan6)#ip address 10.2.3.3 255.255.255.0 console(config-if-vlan6)#ipv6 address 3000:2:3::/64 eui64 4 Associate the interface with area 0.0.0.0 and enable OSPFv3. console(config-if-vlan6)#ip ospf area 0.0.0.0 console(config-if-vlan6)#ipv6 ospf console(config-if-vlan6)#exit 5 Configure IP and IPv6 addresses on VLAN routing interface 12. console(config)#interface vlan 12 console(config-if-vlan12)#ip address 10.3.100.3 255.255.255.0 console(config-if-vlan12)#ipv6 address 3000:3:100::/64 eui64 6 Associate the interface with area 0.0.0.0 and enable OSPFv3. console(config-if-vlan12)#ip ospf area 0.0.0.0 console(config-if-vlan12)#ipv6 ospf Configuring OSPF and OSPFv3 1181 console(config-if-vlan12)#exit 7 Define the OSPF and OSPFv3 router IDs for the switch: console(config)#ipv6 router ospf console(config-rtr)#router-id 3.3.3.3 console(config-rtr)#exit console(config)#router ospf console(config-router)#router-id 3.3.3.3 console(config-router)#exit Switch B is a ABR that connects Area 0 to Areas 1 and 2. To configure Switch B: 1 Configure IPv6 and IPv4 routing. The static routes are included for illustration only: Redistributed static routes, like routes distributed from other protocols, are not injected into stub areas such as Area 1: console#configure console(config)#ipv6 unicast-routing console(config)#ipv6 route 3000:44:44::/64 3000:2:3::210:18ff:fe82:c14 console(config)#ip route 10.23.67.0 255.255.255.0 10.2.3.3 2 Create VLANs 5, 10, and 17. console(config)#vlan 5,10,17 console(config-vlan5,10,17)#interface gi1/0/1 console(config-if-Gi1/0/1)#switchport access vlan 5 console(config-if-Gi1/0/1)#interface gi1/0/2 console(config-if-Gi1/0/2)#switchport access vlan 10 console(config-if-Gi1/0/1)#interface gi1/0/3 console(config-if-Gi1/0/2)#switchport access vlan 17 3 On VLANs 5, 10, and 17, configure IPv4 and IPv6 addresses and enable OSPFv3. For IPv6, associate VLAN 5 with Area 0, VLAN 10 with Area 1, and VLAN 17 with Area 2. 1182 Configuring OSPF and OSPFv3 console(config)#interface vlan 5 console(config-if-vlan5)#ip address 10.2.3.2 255.255.255.0 console(config-if-vlan5)#ipv6 address 3000:2:3::/64 eui64 console(config-if-vlan5)#ipv6 ospf console(config-if-vlan5)#ipv6 ospf areaid 0 console(config-if-vlan5)#exit console(config)#interface vlan 10 console(config-if-vlan10)#ip address 10.1.2.2 255.255.255.0 console(config-if-vlan10)#ipv6 address 3000:1:2::/64 eui64 console(config-if-vlan10)#ipv6 ospf console(config-if-vlan10)#ipv6 ospf areaid 1 console(config-if-vlan10)#exit console(config)#interface vlan 17 console(config-if-vlan17)#ip address 10.2.4.2 255.255.255.0 console(config-if-vlan17)#ipv6 address 3000:2:4::/64 eui64 console(config-if-vlan17)#ipv6 ospf console(config-if-vlan17)#ipv6 ospf areaid 2 console(config-if-vlan17)#exit 4 For IPv4: Configure the router ID, define an OSPF router, and define Area 1 as a stub., and define Area 2 as an NSSA. console(config)#router ospf console(config-router)#router-id 2.2.2.2 console(config-router)#area 0.0.0.1 stub console(config-router)#area 0.0.0.2 nssa 5 For IPv4: Enable OSPF for IPv4 on VLANs 10, 5, and 17 by globally defining the range of IP addresses associated with each interface, and then associating those ranges with Areas 1, 0, and 2, respectively. console(config-router)#network 10.1.2.0 0.0.0.255 area 0.0.0.1 console(config-router)#network 10.2.3.0 0.0.0.255 area 0.0.0.0 Configuring OSPF and OSPFv3 1183 console(config-router)#network 10.2.4.0 0.0.0.255 area 0.0.0.2 6 For IPv4: Configure a metric cost to associate with static routes when they are redistributed via OSPF: console(config-router)#redistribute static metric 1 subnets console(config-router)#exit 7 For IPv6: Define an OSPF router. Define Area 1 as a stub and area 2 as a Not-So-Stubby-Area (NSSA). Configure a metric cost to associate with static routes when they are redistributed via OSPF: console(config)#ipv6 router ospf console(config-rtr)#router-id 2.2.2.2 console(config-rtr)#area 0.0.0.1 stub console(config-rtr)#area 0.0.0.2 nssa console(config-rtr)#redistribute static metric 105 metric-type 1 console(config-rtr)#exit Configuring a Virtual Link for OSPF and OSPFv3 In this example, Area 0 connects directly to Area 1. A virtual link is defined that traverses Area 1 and connects to Area 2. This example assumes other OSPF settings, such as area and interface configuration, have already been configured. Figure 35-37 illustrates the relevant components in this example OSPF configuration. 1184 Configuring OSPF and OSPFv3 Figure 35-37. OSPF Configuration—Virtual Link Switch B is an ABR that directly connects Area 0 to Area 1. Note that in the previous example, Switch B connected to a stub area and an NSSA. Virtual links cannot be created across stub areas or NSSAs. The following commands define a virtual link that traverses Area 1 to Switch C (5.5.5.5). To configure Switch B: 1 Configure the virtual link to Switch C for IPv4. console#configure console(config)#router ospf console(config-router)#area 0.0.0.1 virtual-link 5.5.5.5 console(config-router)#exit 2 Configure the virtual link to Switch C for IPv6. console#configure console(config)#ipv6 router ospf console(config-rtr)#area 0.0.0.1 virtual-link 5.5.5.5 console(config-rtr)#exit Configuring OSPF and OSPFv3 1185 Switch C is a ABR that enables a virtual link from the remote Area 2 in the AS to Area 0. The following commands define a virtual link that traverses Area 1 to Switch B (2.2.2.2). To configure Switch C: 1 For IPv4, assign the router ID, create the virtual link to Switch B, and associate the VLAN routing interfaces with the appropriate areas. console(config)#router ospf console(config-router)#area 0.0.0.1 virtual-link 2.2.2.2 console(config-router)#exit 2 For IPv6, assign the router ID and create the virtual link to Switch B. console(config)#ipv6 router ospf console(config-rtr)#area 0.0.0.1 virtual-link 2.2.2.2 console(config-rtr)#exit 1186 Configuring OSPF and OSPFv3 Interconnecting an IPv4 Backbone and Local IPv6 Network In Figure 35-38, two Dell Networking L3 switches are connected as shown in the diagram. The VLAN 15 routing interface on both switches connects to an IPv4 backbone network where OSPF is used as the dynamic routing protocol to exchange IPv4 routes. OSPF allows device 1 and device 2 to learn routes to each other (from the 20.20.20.x network to the 10.10.10.x network and vice versa). The VLAN 2 routing interface on both devices connects to the local IPv6 network. OSPFv3 is used to exchange IPv6 routes between the two devices. The tunnel interface allows data to be transported between the two remote IPv6 networks over the IPv4 network. Figure 35-38. IPv4 and IPv6 Interconnection Example To configure Switch A: 1 Create the VLANs. console(config)#vlan 2,15 console(config-vlan70,80,90)#interface te1/0/1 console(config-if-Te1/0/1)#switchport mode trunk console(config-if-Te1/0/1)#interface gi1/0/1 console(config-if-Gi1/0/1)#switchport access vlan 2 2 Enable IPv4 and IPv6 routing on the switch. console(config)#ip routing console(config)#ipv6 unicast-routing 3 Set the OSPF router ID. console(config)#router ospf console(config-router)#router-id 1.1.1.1 console(config-router)#exit Configuring OSPF and OSPFv3 1187 4 Set the OSPFv3 router ID. console(config)#ipv6 router ospf console(config-rtr)#router-id 1.1.1.1 console(config-rtr)#exit 5 Configure the IPv4 address and OSPF area for VLAN 15. console(config)#interface vlan 15 console(config-if-vlan15)#ip address 20.20.20.1 255.255.255.0 console(config-if-vlan15)#ip ospf area 0.0.0.0 console(config-if-vlan15)#exit 6 Configure the IPv6 address and OSPFv3 information for VLAN 2. console(config)#interface vlan 2 console(config-if-vlan2)#ipv6 address 2020:1::1/64 console(config-if-vlan2)#ipv6 ospf console(config-if-vlan2)#ipv6 ospf network point-to-point console(config-if-vlan2)#exit 7 Configure the tunnel. console(config)#interface tunnel 0 console(config-if-tunnel0)#ipv6 address 2001::1/64 console(config-if-tunnel0)#tunnel mode ipv6ip console(config-if-tunnel0)#tunnel source 20.20.20.1 console(config-if-tunnel0)#tunnel destination 10.10.10.1 console(config-if-tunnel0)#ipv6 ospf console(config-if-tunnel0)#ipv6 ospf network point-to-point console(config-if-tunnel0)#exit 8 Configure the loopback interface. The switch uses the loopback IP address as the OSPF and OSPFv3 router ID. console(config)#interface loopback 0 console(config-if-loopback0)#ip address 1.1.1.1 255.255.255.0 console(config-if-loopback0)#exit console(config)#exit 1188 Configuring OSPF and OSPFv3 To configure Switch B: 1 Create the VLANs. console(config)#vlan 2,15 console(config-vlan70,80,90)#interface te1/0/1 console(config-if-Te1/0/1)#switchport mode trunk console(config-if-Te1/0/1)#interface gi1/0/1 console(config-if-Gi1/0/1)#switchport access vlan 2 2 Enable IPv4 and IPv6 routing on the switch. console(config)#ip routing console(config)#ipv6 unicast-routing 3 Set the OSPF router ID. console(config)#router ospf console(config-router)#router-id 2.2.2.2 console(config-router)#exit 4 Set the OSPFv3 router ID. console(config)#ipv6 router ospf console(config-rtr)#router-id 2.2.2.2 console(config-rtr)#exit 5 Configure the IPv4 address and OSPF area for VLAN 15. console(config)#interface vlan 15 console(config-if-vlan15)#ip address 10.10.10.1 255.255.255.0 console(config-if-vlan15)#ip ospf area 0.0.0.0 console(config-if-vlan15)#exit 6 Configure the IPv6 address and OSPFv3 information for VLAN 2. console(config)#interface vlan 2 console(config-if-vlan2)#ipv6 address 2020:2::2/64 console(config-if-vlan2)#ipv6 ospf console(config-if-vlan2)#ipv6 ospf network point-to-point console(config-if-vlan2)#exit 7 Configure the tunnel. console(config)#interface tunnel 0 console(config-if-tunnel0)#ipv6 address 2001::2/64 console(config-if-tunnel0)#tunnel mode ipv6ip console(config-if-tunnel0)#tunnel source 10.10.10.1 console(config-if-tunnel0)#tunnel destination 20.20.20.1 console(config-if-tunnel0)#ipv6 ospf console(config-if-tunnel0)#ipv6 ospf network point-to-point console(config-if-tunnel0)#exit Configuring OSPF and OSPFv3 1189 8 Configure the loopback interface. The switch uses the loopback IP address as the OSPF and OSPFv3 router ID. console(config)#interface loopback 0 console(config-if-loopback0)#ip address 2.2.2.2 255.255.255.0 console(config-if-loopback0)#exit console(config)#exit Configuring the Static Area Range Cost Figure 35-39 shows a topology for the configuration that follows. Figure 35-39. Static Area Range Cost Example Topology R3 Area 0 VLAN 103 ABR R0 VLAN 101 R1 VLAN 102 VLAN 104 Area 1 1 Configure R0. terminal length 0 config hostname ABR-R0 line console exec-timeout 0 exit vlan 101-103 exit ip routing router ospf router-id 10.10.10.10 1190 Configuring OSPF and OSPFv3 R2 network 172.20.0.0 0.0.255.255 area 0 network 172.21.0.0 0.0.255.255 area 1 area 1 range 172.21.0.0 255.255.0.0 summarylink timers spf 3 5 exit interface vlan 101 ip address 172.21.1.10 255.255.255.0 ip ospf hello-interval 1 ip ospf dead-interval 4 ip ospf network point-to-point exit interface te1/0/21 switchport mode trunk description “R1” exit interface vlan 102 ip address 172.21.2.10 255.255.255.0 ip ospf hello-interval 1 ip ospf dead-interval 4 ip ospf network point-to-point exit interface te1/0/22 description “R2” switchport mode trunk exit interface vlan 103 ip address 172.20.1.10 255.255.255.0 ip ospf hello-interval 1 ip ospf dead-interval 4 ip ospf network point-to-point exit interface te1/0/23 switchport mode trunk description “R3” exit exit 2 Configure R1. terminal length 0 config hostname R1 line console exec-timeout 0 exit vlan 101,104 exit Configuring OSPF and OSPFv3 1191 ip routing router ospf router-id 1.1.1.1 network 172.21.0.0 0.0.255.255 area 1 timers spf 3 5 exit interface vlan 101 ip address 172.21.1.1 255.255.255.0 routing ip ospf hello-interval 1 ip ospf dead-interval 4 ip ospf network point-to-point exit interface te1/0/21 switchport mode trunk exit interface vlan 104 ip address 172.21.3.1 255.255.255.0 routing ip ospf hello-interval 1 ip ospf dead-interval 4 ip ospf network point-to-point exit interface te1/0/22 switchport mode trunk exit interface loopback 0 ip address 172.21.254.1 255.255.255.255 exit exit 3 Configure R2. terminal length 0 config line console serial timeout 0 exit ip routing router ospf router-id 2.2.2.2 network 172.21.0.0 0.0.255.255 area 1 timers spf 3 5 exit vlan 102,104 exit interface vlan 102 1192 Configuring OSPF and OSPFv3 ip address 172.21.2.2 255.255.255.0 routing ip ospf hello-interval 1 ip ospf dead-interval 4 ip ospf network point-to-point exit interface te1/0/21 switchport mode trunk exit interface vlan 104 ip address 172.21.3.2 255.255.255.0 routing ip ospf hello-interval 1 ip ospf dead-interval 4 ip ospf network point-to-point exit interface te1/0/22 switchport mode trunk exit interface loopback 0 ip address 172.21.254.2 255.255.255.255 exit exit 4 R3 config: terminal length 0 config line console serial timeout 0 exit ip routing router ospf router-id 3.3.3.3 network 172.21.0.0 0.0.255.255 area 0 timers spf 3 5 exit vlan 103 exit interface vlan 103 ip address 172.21.1.1 255.255.255.0 routing ip ospf hello-interval 1 ip ospf dead-interval 4 ip ospf network point-to-point exit interface te1/0/21 Configuring OSPF and OSPFv3 1193 switchport mode trunk exit interface loopback 0 ip address 172.21.254.2 255.255.255.255 exit exit Discussion With no area range cost specified, the range uses auto cost: (ABR-R0) #show ip ospf range 1 Prefix 172.21.0.0 Subnet Mask 255.255.0.0 Type S Action Advertise Cost Auto Active Y (ABR-R0) #show ip ospf database summary Network Summary States (Area 0.0.0.0) LS Age: 644 LS options: (E-Bit) LS Type: Network Summary LSA LS Id: 172.21.0.0 (network prefix) Advertising Router: 10.10.10.10 LS Seq Number: 0x80000002 Checksum: 0x8ee1 Length: 28 Network Mask: 255.255.0.0 Metric: 2 Min—The cost can be set to 0, the minimum value. OSPF re-advertises the summary LSA with a metric of 0: (ABR-R0) (config-router)#area 1 range 172.21.0.0 255.255.0.0 summarylink advertise cost ? <0-16777215> Set area range cost (ABR-R0) (config-router)#area 1 range 172.21.0.0 255.255.0.0 summarylink advertise cost 0 (ABR-R0) #show ip ospf range 1 Prefix 172.21.0.0 Subnet Mask 255.255.0.0 Type S Action Advertise (ABR-R0) #show ip ospf 0 database summary Network Summary States (Area 0.0.0.0) 1194 Configuring OSPF and OSPFv3 Cost 0 Active Y LS Age: 49 LS options: (E-Bit) LS Type: Network Summary LSA LS Id: 172.21.0.0 (network prefix) Advertising Router: 10.10.10.10 LS Seq Number: 0x80000003 Checksum: 0x78f8 Length: 28 Network Mask: 255.255.0.0 Metric: 0 The cost can be set to the maximum value, 16,777,215, which is LSInfinity. Since OSPF cannot send a type 3 summary LSA with this metric (according to RFC 2328), the summary LSA is flushed. The individual routes are not readvertised. Configuring Flood Blocking Figure 35-40 shows an example topology for flood blocking. The configuration follows. Figure 35-40. Flood Blocking Topology R3 VLAN 103 R0 VLAN 101 R1 VLAN 102 VLAN 104 R2 1 Configure R0: terminal length 0 config hostname R0 line console Configuring OSPF and OSPFv3 1195 exec-timeout 0 exit vlan 101-103 exit ip routing router ospf router-id 10.10.10.10 network 172.20.0.0 0.0.255.255 area 0 network 172.21.0.0 0.0.255.255 area 0 timers spf 3 5 exit interface vlan 101 ip address 172.21.1.10 255.255.255.0 ip ospf hello-interval 1 ip ospf dead-interval 4 ip ospf network point-to-point exit interface te1/0/21 switchport mode trunk description “R1” exit interface vlan 102 ip address 172.21.2.10 255.255.255.0 ip ospf hello-interval 1 ip ospf dead-interval 4 ip ospf network point-to-point exit interface te1/0/22 description “R2” switchport mode trunk exit interface vlan 103 ip address 172.20.1.10 255.255.255.0 ip ospf hello-interval 1 ip ospf dead-interval 4 ip ospf network point-to-point exit interface te1/0/23 switchport mode trunk description “R3” exit exit 2 Configure R1: terminal length 0 1196 Configuring OSPF and OSPFv3 config hostname R1 line console exec-timeout 0 exit vlan 101,104 exit ip routing router ospf router-id 1.1.1.1 network 172.21.0.0 0.0.255.255 area 0 timers spf 3 5 exit interface vlan 101 ip address 172.21.1.1 255.255.255.0 routing ip ospf hello-interval 1 ip ospf dead-interval 4 ip ospf network point-to-point exit interface te1/0/21 switchport mode trunk exit interface vlan 104 ip address 172.21.3.1 255.255.255.0 routing ip ospf hello-interval 1 ip ospf dead-interval 4 ip ospf network point-to-point exit interface te1/0/22 switchport mode trunk exit interface loopback 0 ip address 172.21.254.1 255.255.255.255 exit exit 3 Configure R2: terminal length 0 config line console serial timeout 0 exit ip routing Configuring OSPF and OSPFv3 1197 router ospf router-id 2.2.2.2 network 172.21.0.0 0.0.255.255 area 0 timers spf 3 5 exit vlan 102,104 exit interface vlan 102 ip address 172.21.2.2 255.255.255.0 routing ip ospf hello-interval 1 ip ospf dead-interval 4 ip ospf network point-to-point exit interface te1/0/21 switchport mode trunk exit interface vlan 104 ip address 172.21.3.2 255.255.255.0 routing ip ospf hello-interval 1 ip ospf dead-interval 4 ip ospf network point-to-point exit interface te1/0/22 switchport mode trunk exit interface loopback 0 ip address 172.21.254.2 255.255.255.255 exit exit 4 Configure R3: terminal length 0 config line console serial timeout 0 exit ip routing router ospf router-id 3.3.3.3 network 172.21.0.0 0.0.255.255 area 0 timers spf 3 5 exit vlan 103 1198 Configuring OSPF and OSPFv3 exit interface vlan 103 ip address 172.21.1.1 255.255.255.0 routing ip ospf hello-interval 1 ip ospf dead-interval 4 ip ospf network point-to-point exit interface te1/0/21 switchport mode trunk exit interface loopback 0 ip address 172.21.254.2 255.255.255.255 exit exit Discussion With flood blocking disabled on all interfaces, sending a T3 summary LSA from R3 to R0 will cause R0 to forward the LSA on its interface to R1. Enabling flood blocking on R0's interface to R1 will inhibit this behavior. (R0)(config-if-vlan101)ip ospf database-filter all out A trace on the R3-R0 link shows that the LSA is actually flooded from R1 to R0, since R1 received the LSA via R2. Even though R1 does not receive this LSA directly from R0, it still correctly computes the route through the R0: (R1) #show ip route console#show ip route Route Codes: R - RIP Derived, O - OSPF Derived, C - Connected, S - Static B - BGP Derived, E - Externaly Derived, IA - OSPF Inter Area E1 - OSPF External Type 1, E2 - OSPF External Type 2 N1 - OSPF NSSA External Type 1, N2 - OSPF NSSA External Type 2 O IA 100.0.0.0/24 [110/2] via 172.21.1.10, 00h:01m:35s, 0/25 OSPF also blocks external LSAs on the blocked interface. Stopping and restarting R3's OSPF protocol causes R3 to re-originate its router LSA. R0 does not send R3's router LSA on the blocked interface. With flood blocking enabled on the R0 interface, if the link from R0 to R1 bounces, R0 Database Description packets do not include any LSAs. However, database synchronization still occurs (through R2) and R1 computes the correct routes after the link is restored. Configuring OSPF and OSPFv3 1199 1200 Configuring OSPF and OSPFv3 Configuring RIP 36 This chapter describes how to configure Routing Information Protocol (RIP) on the switch. RIP is a dynamic routing protocol for IPv4 networks. The topics covered in this chapter include: • RIP Overview • Default RIP Values • Configuring RIP Features (Web) • Configuring RIP Features (CLI) • RIP Configuration Example RIP Overview RIP is an Interior Gateway Protocol (IGP) that performs dynamic routing within a network. Dell Networking series switches support two dynamic routing protocols: OSPF and Routing Information Protocol (RIP). Unlike OSPF, RIP is a distance-vector protocol and uses UDP broadcasts to maintain topology information and hop counts to determine the best route to transmit IP traffic. RIP is best suited for small, homogenous networks. How Does RIP Determine Route Information? The routing information is propagated in RIP update packets that are sent out both periodically and in the event of a network topology change. On receipt of a RIP update, depending on whether the specified route exists or does not exist in the route table, the router may modify, delete or add the route to its route table. RIP uses hop count, which is the number of routers an IP packet must pass through, to calculate the best route for a packet. A route with a low hop count is preferred over a route with a higher hop count. A directly-connected route has a hop-count of 0. With RIP, the maximum number of hops from source to destination is 15. Packets with a hop count greater than 15 are dropped because the destination network is considered unreachable. Configuring RIP 1201 What Is Split Horizon? RIP uses a technique called split horizon to avoid problems caused by including routes in updates sent to the router from which the route was originally learned. With simple split horizon, a route is not included in updates sent on the interface on which it was learned. In split horizon with poison reverse, a route is included in updates sent on the interface where it was learned, but the metric is set to infinity. What RIP Versions Are Supported? There are two versions of RIP: • • RIP-1 defined in RFC 1058 – Routes are specified by IP destination network and hop count – The routing table is broadcast to all stations on the attached network RIP-2 defined in RFC 1723 – Route specification is extended to include subnet mask and gateway – The routing table is sent to a multicast address, reducing network traffic – An authentication method is used for security The Dell Networking series switches support both versions of RIP. You may configure a given port: • To receive packets in either or both formats • To transmit packets formatted for RIP-1 or RIP-2 or to send RIP-2 packets to the RIP-1 broadcast address • To prevent any RIP packets from being received • To prevent any RIP packets from being transmitted 1202 Configuring RIP Default RIP Values RIP is globally enabled by default. To make it operational on the router, you configure and enable RIP for particular VLAN routing interfaces. Table 36-1 shows the global default values for RIP. Table 36-1. RIP Global Defaults Parameter Default Value Admin Mode Enabled Split Horizon Mode Simple Auto Summary Mode Disabled Host Routes Accept Mode Enabled Default Information Originate Disabled Default Metric None configured Route Redistribution Disabled for all sources. Table 36-2 shows the per-interface default values for RIP. Table 36-2. RIP Per-Interface Defaults Parameter Default Value Admin Mode Disabled Send Version RIPv2 Receive Version Both Authentication Type None Configuring RIP 1203 Configuring RIP Features (Web) This section provides information about the OpenManage Switch Administrator pages for configuring and monitoring RIP features on a Dell Networking N2000, N3000, and N4000 series switches. For details about the fields on a page, click at the top of the page. RIP Configuration Use the Configuration page to enable and configure or disable RIP in Global mode. To display the page, click Routing → RIP → Configuration in the navigation panel. Figure 36-1. RIP Configuration 1204 Configuring RIP RIP Interface Configuration Use the Interface Configuration page to enable and configure or to disable RIP on a specific interface. To display the page, click Routing → RIP → Interface Configuration in the navigation panel. Figure 36-2. RIP Interface Configuration Configuring RIP 1205 RIP Interface Summary Use the Interface Summary page to display RIP configuration status on an interface. To display the page, click Routing → RIP → Interface Summary in the navigation panel. Figure 36-3. RIP Interface Summary 1206 Configuring RIP RIP Route Redistribution Configuration Use the Route Redistribution Configuration page to configure the RIP Route Redistribution parameters. The allowable values for each fields are displayed next to the field. If any invalid values are entered, an alert message is displayed with the list of all the valid values. To display the page, click Routing → RIP → Route Redistribution Configuration in the navigation panel. Figure 36-4. RIP Route Redistribution Configuration NOTE: Static reject routes are not redistributed by RIP. For a static reject route, the next hop interface value is Null0. Packets to the network address specified in static reject routes are intentionally dropped. Configuring RIP 1207 RIP Route Redistribution Summary Use the Route Redistribution Summary page to display Route Redistribution configurations. To display the page, click Routing → RIP → Route Redistribution Summary in the navigation panel. Figure 36-5. RIP Route Redistribution Summary 1208 Configuring RIP Configuring RIP Features (CLI) This section provides information about the commands you use to configure RIP settings on the switch. For more information about the commands, see the Dell Networking N2000, N3000, and N4000 Series Switches CLI Reference Guide at support.dell.com/manuals. Configuring Global RIP Settings Beginning in Privileged EXEC mode, use the following commands to configure various global RIP settings for the switch. NOTE: RIP is enabled by default. The Global RIP Settings are optional. Command Purpose configure Enter global configuration mode. router rip Enter OSPF configuration mode. split-horizon {none | Set the RIP split horizon mode. simple | poison} • none — RIP does not use split horizon to avoid routing loops. • simple — RIP uses split horizon to avoid routing loops. • poison — RIP uses split horizon with poison reverse (increases routing packet update size). auto-summary Enable the RIP auto-summarization mode. no hostroutesaccept Prevent the switch from accepting host routes. default-information originate Control the advertisement of default routes. default-metric metric- Set a default for the metric of distributed routes. value The metric-value variable is the metric (or preference) value of the default route. (Range: 1–15) enable Reset the default administrative mode of RIP in the router (active) CTRL + Z Exit to Privileged EXEC mode. show ip rip View various RIP settings for the switch. Configuring RIP 1209 Configuring RIP Interface Settings Beginning in Privileged EXEC mode, use the following commands to configure per-interface RIP settings. Command Purpose configure Enter global configuration mode. interface vlan vlan-id Enter Interface Configuration mode for the specified VLAN. ip rip Enable RIP on the interface. ip rip send version {rip1 Configure the interface to allow RIP control packets of the rip1c | rip2 |none} specified version(s) to be sent. ip rip receive version {rip1 | rip2 | both | none} Configure the interface to allow RIP control packets of the specified version(s) to be received. ip rip authentication {none | {simple key} | {encrypt key key-id} set the RIP Version 2 Authentication Type and Key for the interface. • key — Authentication key for the specified interface. (Range: 16 bytes or less) • encrypt — Specifies the Ethernet unit/port of the interface to view information. • key-id — Authentication key identifier for authentication type encrypt. (Range: 0-255) exit Exit to Global Configuration Mode exit Exit to Privileged Exec mode. show ip rip interface vlan View RIP configuration information for the specified routing interface. vlan-id show ip rip interface brief 1210 Configuring RIP View summary information about the RIP configuration on all interfaces. Configuring Route Redistribution Settings Beginning in Privileged EXEC mode, use the following commands to configure an OSPF area range and to configure route redistribution settings. Command Purpose configure Enter global configuration mode. router rip Enter RIP configuration mode. distribute-list Specify the access list to filter routes received from the static | connected} switch. For information about the commands you use to configure ACLs, see "Configuring ACLs (CLI)" on page 612. accesslistname out {ospf | source protocol. The ACL must already exist on the • accesslistname — The name used to identify an existing ACL. • ospf — Apply the specified access list when OSPF is the source protocol. • static — Apply the specified access list when packets come through the static route. • connected — Apply the specified access list when packets come from a directly connected route. redistribute {static | connected} [metric integer] Configure RIP to allow redistribution of routes from the specified source protocol/routers. • static — Specifies that the source is a static route. • connected — Specifies that the source is a directly connected route. • metric — Specifies the metric to use when redistributing the route. Range: 1-15. Configuring RIP 1211 Command Purpose redistribute ospf [metric Configure RIP to allow redistribution of routes from the metric] [match [internal] OSPF. [external 1] [external 2] • ospf— Specifies OSPF as the source protocol. [nssa-external 1] [nssa• metric — Specifies the metric to use when external 2]] redistributing the route. Range: 1-15. • internal — Adds internal matches to any match types presently being redistributed. • external 1 — Adds routes imported into OSPF as Type1 external routes into any match types presently being redistributed. • external 2 — Adds routes imported into OSPF as Type2 external routes into any match types presently being redistributed. • nssa-external 1 — Adds routes imported into OSPF as NSSA Type-1 external routes into any match types presently being redistributed. • nssa-external 2 — Adds routes imported into OSPF as NSSA Type-2 external routes into any match types presently being redistributed. distance rip integer Set the route preference value of RIP in the router. Lower route preference values are preferred when determining the best route. exit Exit to Global Config mode. exit Exit to Privileged Exec mode. show ip rip View information about the RIP route distribution configuration. 1212 Configuring RIP RIP Configuration Example This example includes four Dell Networking switches that use RIP to determine network topology and route information. The commands in this example configure Switch A shown in Figure 36-6. Figure 36-6. RIP Network Diagram To configure the switch: 1 Enable routing on the switch console#config console(config)#ip routing 2 Create VLANs 10, 20, and 30. console(config)#vlan 10,20,30 console(config-vlan10,20,30)#interface gi1/0/1 console(config-if-Gi1/0/1)#switchport access vlan 10 console(config-if-Gi1/0/1)#interface gi1/0/2 console(config-if-Gi1/0/2)#switchport access vlan 20 console(config-if-Gi1/0/2)#interface gi1/0/3 console(config-if-Gi1/0/3)#switchport access vlan 30 3 Assign an IP address and enable RIP on each interface. Additionally, the commands specify that each interface can receive both RIP-1 and RIP-2 frames but send only RIP-2 formatted frames. console(config)#interface vlan 10 Configuring RIP 1213 console(config-if-vlan10)#ip address 192.168.10.1 255.255.255.0 console(config-if-vlan10)#ip rip console(config-if-vlan10)#ip rip receive version both console(config-if-vlan10)#ip rip send version rip2 console(config-if-vlan10)#exit console(config)#interface vlan 20 console(config-if-vlan20)#ip address 192.168.20.1 255.255.255.0 console(config-if-vlan20)#ip rip console(config-if-vlan20)#ip rip receive version both console(config-if-vlan20)#ip rip send version rip2 console(config-if-vlan20)#exit console(config)#interface vlan 30 console(config-if-vlan30)#ip address 192.168.30.1 255.255.255.0 console(config-if-vlan30)#ip rip console(config-if-vlan30)#ip rip receive version both console(config-if-vlan30)#ip rip send version rip2 console(config-if-vlan30)#exit 4 Enable auto summarization of subprefixes when crossing classful boundaries. console(config)#router rip console(config-router)#auto-summary console(config-router)#exit console(config)#exit 5 Verify the configuration console#show ip rip RIP Admin Mode.......................... Split Horizon Mode...................... Auto Summary Mode....................... Host Routes Accept Mode................. Global route changes.................... Global queries.......................... Enable Simple Enable Enable 0 0 Default Metric.................... Not configured Default Route Advertise........... 0 console#show ip rip interface brief Interface IP Address ---------- -----------Vl1 0.0.0.0 1214 Configuring RIP Send Version --------RIP-2 Receive Version ------RIP-2 RIP Mode -------Disable Link State -----Down Vl10 Vl20 Vl30 192.168.10.1 192.168.10.1 192.168.10.1 RIP-2 RIP-2 RIP-2 Both Both Both Enable Enable Disable Configuring RIP Down Down Down 1215 1216 Configuring RIP 37 Configuring VRRP NOTE: This feature is not available on N2000 switches. This chapter describes how to configure Virtual Routing Redundancy Protocol (VRRP) on the switch. VRRP can help create redundancy on networks in which end-stations are statically configured with the default gateway IP address. The topics covered in this chapter include: • VRRP Overview • Default VRRP Values • Configuring VRRP Features (Web) • Configuring VRRP Features (CLI) • VRRP Configuration Example VRRP Overview The Virtual Router Redundancy (VRRP) protocol is designed to handle default router (L3 switch) failures by providing a scheme to dynamically elect a backup router. VRRP can help minimize black hole periods due to the failure of the default gateway router during which all traffic directed towards it is lost until the failure is detected. How Does VRRP Work? VRRP eliminates the single point of failure associated with static default routes by enabling a backup router to take over from a master router without affecting the end stations using the route. The end stations will use a virtual IP address that will be recognized by the backup router if the master router fails. Participating routers use an election protocol to determine which router is the master router at any given time. A maximum of 50 virtual routers may Configuring VRRP 1217 be configured. A given port may appear as more than one virtual router to the network, also, more than one port on a switch may be configured as a virtual router. With VRRP, a virtual router is associated with one or more IP addresses that serve as default gateways. In the event that the VRRP router controlling these IP addresses (formally known as the master) fails, the group of IP addresses and the default forwarding role is taken over by a Backup VRRP router. What Is the VRRP Router Priority? The VRRP router priority is a value from 1–255 that determines which router is the master. The greater the number, the higher the priority. If the virtual IP address is the IP address of a VLAN routing interface on one of the routers in the VRRP group, the router with IP address that is the same as the virtual IP address is the interface owner and automatically has a priority of 255. By default, this router is the VRRP master in the group. If no router in the group owns the VRRP virtual IP address, the router with the highest configured priority is the VRRP master. If multiple routers have the same priority, the router with the highest IP address becomes the VRRP master. If the VRRP master fails, other members of the VRRP group will elect a master based on the configured router priority values. For example, router A is the interface owner and master, and it has a priority of 255. Router B is configured with a priority of 200, and Router C is configured with a priority of 190. If Router A fails, Router B assumes the role of VRRP master because it has a higher priority. What Is VRRP Preemption? If preempt mode is enabled and a router with a higher priority joins the VRRP group, it takes over the VRRP master role if the current VRRP master is not the owner of the virtual IP address. The preemption delay controls how long to wait to determine whether a higher priority Backup router preempts a lower priority master. In certain cases, for example, during periods of network congestion, a backup router might fail to receive advertisements from the master. This could cause members in the VRRP group to change their states frequently, i.e. flap. The problem can be resolved by setting the VRRP preemption delay timer to a non-zero value. 1218 Configuring VRRP What Is VRRP Accept Mode? The accept mode allows the switch to respond to pings (ICMP Echo Requests) sent to the VRRP virtual IP address. The VRRP specification (RFC 3768) indicates that a router may accept IP packets sent to the virtual router IP address only if the router is the address owner. In practice, this restriction makes it more difficult to troubleshoot network connectivity problems. When a host cannot communicate, it is common to ping the host's default gateway to determine whether the problem is in the first hop of the path to the destination. When the default gateway is a virtual router that does not respond to pings, this troubleshooting technique is unavailable. In the Dell Networking switch VRRP feature, you can enable Accept Mode to allow the system to respond to pings that are sent to the virtual IP address. This capability adds support for responding to pings, but does not allow the VRRP master to accept other types of packets. The VRRP master responds to both fragmented and un-fragmented ICMP Echo Request packets. The VRRP master responds to Echo Requests sent to the virtual router's primary address or any of its secondary addresses. Members of the virtual router who are in backup state discard ping packets destined to VRRP addresses, just as they discard any Ethernet frame sent to a VRRP MAC address. When the VRRP master responds with an Echo Reply, the source IPv4 address is the VRRP address and source MAC address is the virtual router's MAC address. What Are VRRP Route and Interface Tracking? The VRRP Route/Interface Tracking feature extends VRRP capability to allow tracking of specific routes and interface IP states within the router that can alter the priority level of a virtual router for a VRRP group. VRRP interface tracking monitors a specific interface IP state within the router. Depending on the state of the tracked interface, the feature can alter the VRRP priority level of a virtual router for a VRRP group. NOTE: An exception to the priority level change is that if the VRRP group is the IP address owner, its priority is fixed at 255 and cannot be reduced through the tracking process. Configuring VRRP 1219 With standard VRRP, the backup router takes over only if the router goes down. With VRRP interface tracking, if a tracked interface goes down on the VRRP master, the priority decrement value is subtracted from the router priority. If the master router priority becomes less than the priority on the backup router, the backup router takes over. If the tracked interface becomes up, the value of the priority decrement is added to the current router priority. If the resulting priority is more than the backup router priority, the original VRRP master resumes control. VRRP route tracking monitors the reachability of an IP route. A tracked route is considered up when a routing table entry exists for the route and the route is accessible. When the tracked route is removed from the routing table, the priority of the VRRP router will be reduced by the priority decrement value. When the tracked route is added to the routing table, the priority will be incremented by the same. 1220 Configuring VRRP Default VRRP Values Table 37-1 shows the global default values for VRRP. Table 37-1. VRRP Defaults Parameter Default Value Admin Mode Disabled Virtual Router ID (VRID) None (Range 1-255) Preempt Mode Enabled Preempt Delay 0 Seconds Learn Advertisement Timer Interval Enabled Accept Mode Disabled Priority 100 Advertisement Interval 1 Authentication None Route Tracking No routes tracked Interface Tracking No interfaces tracked Configuring VRRP 1221 Configuring VRRP Features (Web) This section provides information about the OpenManage Switch Administrator pages for configuring and monitoring VRRP features on a Dell Networking N2000, N3000, and N4000 series switches. For details about the fields on a page, click at the top of the page. VRRP Configuration Use the Configuration page to enable or disable the administrative status of a virtual router. To display the page, click Routing → VRRP → Configuration in the navigation panel. Figure 37-1. VRRP Configuration 1222 Configuring VRRP VRRP Virtual Router Status Use the Router Status page to display virtual router status. To display the page, click Routing → VRRP → Router Status in the navigation panel. Figure 37-2. Virtual Router Status Configuring VRRP 1223 VRRP Virtual Router Statistics Use the Router Statistics page to display statistics for a specified virtual router. To display the page, click Routing → VRRP → Router Statistics in the navigation panel. Figure 37-3. Virtual Router Statistics 1224 Configuring VRRP VRRP Router Configuration Use the Configuration page to configure a virtual router. To display the page, click Routing → VRRP → Router Configuration → Configuration in the navigation panel. Figure 37-4. VRRP Router Configuration Configuring VRRP 1225 VRRP Route Tracking Configuration Use the Route Tracking Configuration page to view routes that are tracked by VRRP and to add new tracked routes. To display the page, click Routing → VRRP → Router Configuration → Route Tracking Configuration in the navigation panel. Figure 37-5. VRRP Route Tracking Configuration Configuring VRRP Route Tracking To configure VRRP route tracking: 1 From the Route Tracking Configuration page, click Add. The Add Route Tracking page displays. 1226 Configuring VRRP Figure 37-6. Add Route Tracking 2 Select the virtual router ID and VLAN routing interface that will track the route. 3 Specify the destination network address (track route prefix) for the route to track. Use dotted decimal format, for example 192.168.10.0. 4 Specify the prefix length for the tracked route. 5 Specify a value for the Priority Decrement to define the amount that the router priority will be decreased when a tracked route becomes unreachable. 6. Click Apply to update the switch. Configuring VRRP 1227 VRRP Interface Tracking Configuration Use the Interface Tracking Configuration page to view interfaces that are tracked by VRRP and to add new tracked interfaces. To display the page, click Routing → VRRP → Router Configuration → Interface Tracking Configuration in the navigation panel. Figure 37-7. VRRP Interface Tracking Configuration Configuring VRRP Interface Tracking To configure VRRP interface tracking: 1 From the Interface Tracking Configuration page, click Add. The Add Interface Tracking page displays. 1228 Configuring VRRP Figure 37-8. VRRP Interface Tracking Configuration 2 Select the virtual router ID and VLAN routing interface that will track the interface. 3 Specify the interface to track. 4 Specify a value for the Priority Decrement to define the amount that the router priority will be decreased when a tracked interface goes down. 5. Click Apply to update the switch. Configuring VRRP 1229 Configuring VRRP Features (CLI) This section provides information about the commands you use to configure VRRP settings on the switch. For more information about the commands, see the Dell Networking N2000, N3000, and N4000 Series Switches CLI Reference Guide at support.dell.com/manuals. Configuring VRRP Settings Beginning in Privileged EXEC mode, use the following commands to configure switch and interface VRRP settings. This set of commands also describes how to configure VRRP interface and route tracking. Command Purpose configure Enter global configuration mode. ip vrrp Enable the administrative mode of VRRP for the router (L3 switch). interface vlan vlan-id Enter Interface Configuration mode for the specified VLAN. vrrp vr-id Allow the interface to create in the VRRP group specified by the vr-id parameter, which is a number from 1–255. vrrp vr-id description (Optional) Create a text description that identifies the VRRP group. vrrp vr-id preempt [delay Enable the preemption mode value for the virtual router seconds] configured on a specified interface. You can optionally configure a preempt delay, which is the number of seconds the VRRP router waits before the VRRP router sends an advertisement to claim master ownership. vrrp vr-id accept-mode Allow the VRRP master to accept ping packets sent to one of the virtual router’s IP addresses. vrrp vr-id priority priority Set the priority value for the virtual router configured on the interface. vrrp vr-id ip ip-address [secondary] Set the virtual router IP address value for an interface. 1230 Configuring VRRP Command Purpose vrrp vr-id timers {learn | Configure the VRRP timer settings. advertise seconds} Use the keyword learn to enable VRRP to learn the advertisement timer interval of the master router. Use the keyword advertise to set the frequency, in seconds, that an interface on the specified virtual router sends a virtual router advertisement. vrrp vr-id authentication Set the authorization details value for the virtual router configured on a specified interface. {none | simple key} • vr-id — The virtual router identifier. (Range: 1-255) • none — Indicates authentication type is none. • simple — Authentication type is a simple text password. • key — The key for simple authentication. (Range: String values) vrrp vr-id mode Enable the virtual router configured on an interface, which starts the virtual router. vrrp vr-id track interface Specify an interface the virtual router (vr-id) on the vlan vlan-id [decrement interface will track. If the interface goes down, the virtual priority] router priority is decreased by the amount specified by the priority value. vrrp vr-id track ip route Specify a route that the virtual router (vr-id) on the interface will track. If the route to the destination network specified by the ip-address/prefix-length variable is removed from the routing table, the virtual router priority is decreased by the amount specified by the priority value. CTRL + Z Exit to Privileged EXEC mode. show vrrp [vr-id] View settings for all VRRP groups or for the specified VRRP group for the switch. show vrrp brief View a summary of interfaces configured to participate in VRRP groups. show vrrp interface {brief | vlan vlan-id [stats]} View information about VRRP settings configured on all interfaces or on the specified interface. If you specify an interface, use the keyword stats to view VRRP statistics for the interface. ip-address/prefix-length [decrement priority] Configuring VRRP 1231 VRRP Configuration Example This section contains the following VRRP examples: • VRRP with Load Sharing • VRRP with Route and Interface Tracking VRRP with Load Sharing In Figure 37-9, two L3 Dell Networking switches are performing the routing for network clients. Router A is the default gateway for some clients, and Router B is the default gateway for other clients. Figure 37-9. VRRP with Load Sharing Network Diagram 1232 Configuring VRRP This example configures two VRRP groups on each router. Router A is the VRRP master for the VRRP group with VRID 10 and the backup for VRID 20. Router B is the VRRP master for VRID 20 and the backup for VRID 10. If Router A fails, Router B will become the master of VRID 10 and will use the virtual IP address 192.168.10.1. Traffic from the clients configured to use Router A as the default gateway will be handled by Router B. To configure Router A: 1 Enable routing for the switch. console#config console(config)#ip routing 2 Create and configure the VLAN routing interface to use as the default gateway for network clients. This example assumes all other routing interfaces, such as the interface to the external network, have been configured. console(config)#interface vlan 10 console(config-if-vlan10)#ip address 192.168.10.1 255.255.255.0 console(config-if-vlan10)#exit 3 Enable VRRP for the switch. console(config)#ip vrrp 4 Assign a virtual router ID to the VLAN routing interface for the first VRRP group. console(config)#interface vlan 10 console(config-if-vlan10)#vrrp 10 5 Specify the IP address that the virtual router function will use. The router is the virtual IP address owner (the routing interface has the same IP address as the virtual IP address for the VRRP group), so the priority value is 255. console(config-if-vlan10)#vrrp 10 ip 192.168.10.1 6 Configure an optional description to help identify the VRRP group. console(config-if-vlan10)#vrrp 10 description master 7 Assign a virtual router ID to the VLAN routing interface for the second VRRP group. console(config-if-vlan10)#vrrp 20 8 Specify the IP address that the virtual router function will use. console(config-if-vlan10)#vrrp 20 ip 192.168.10.2 Configuring VRRP 1233 9 Configure an optional description to help identify the VRRP group. console(config-if-vlan10)#vrrp 20 description backup 10 Enable the VRRP groups on the interface. console(config-if-vlan10)#vrrp 10 mode console(config-if-vlan10)#vrrp 20 mode console(config-if-vlan10)#exit console(config)#exit The only difference between the Router A and Router B configurations is the IP address assigned to VLAN 10. On Router B, the IP address of VLAN 10 is 192.168.10.2. Because this is also the virtual IP address of VRID 20, Router B is the interface owner and VRRP master of VRRP group 20. To configure Router B: 1 Enable routing for the switch. console#config console(config)#ip routing 2 Create and configure the VLAN routing interface to use as the default gateway for network clients. This example assumes all other routing interfaces, such as the interface to the external network, have been configured. console(config)#interface vlan 10 console(config-if-vlan10)#ip address 192.168.10.2 255.255.255.0 console(config-if-vlan10)#exit 3 Enable VRRP for the switch. console(config)#ip vrrp 4 Assign a virtual router ID to the VLAN routing interface for the first VRRP group. console(config)#interface vlan 10 console(config-if-vlan10)#vrrp 10 5 Specify the IP address that the virtual router function will use. console(config-if-vlan10)#vrrp 10 ip 192.168.10.1 6 Configure an optional description to help identify the VRRP group. console(config-if-vlan10)#vrrp 10 description master 7 Assign a virtual router ID to the VLAN routing interface for the second VRRP group. console(config-if-vlan10)#vrrp 20 1234 Configuring VRRP 8 Specify the IP address that the virtual router function will use. The router is the virtual IP address owner of this address, so the priority value is 255 by default. console(config-if-vlan10)#vrrp 20 ip 192.168.10.2 9 Configure an optional description to help identify the VRRP group. console(config-if-vlan10)#vrrp 20 description backup 10 Enable the VRRP groups on the interface. console(config-if-vlan10)#vrrp 10 mode console(config-if-vlan10)#vrrp 20 mode console(config-if-vlan10)#exit console(config)#exit Troubleshooting VRRP When configuring VRRP, ensure that the L2 network facing the VRRP router is up. Both VRRP peers will show as being in the “Master” state until the layer 2 network is operational. Likewise, ensure that the link or path between the virtual routers is operational. If the link is not operational, one VR instance will show as “Master” and the other VR instance will show as “Initializing.” Check the spanning-tree state on the routed links. Routed links must show as forwarding. Disable spanning tree on the routed links if necessary to prevent spanning tree from blocking routed links. Configuring VRRP 1235 VRRP with Route and Interface Tracking In Figure 37-10, the VRRP priorities are configured so that Router A is the VRRP master, and Router B is the VRRP backup. Router A forwards IP traffic from clients to the external network through the VLAN 25 routing interface. The clients are configured to use the virtual IP address 192.168.10.15 as the default gateway. Figure 37-10. VRRP with Tracking Network Diagram Without VRRP interface or route tracking, if something happened to VLAN 25 or the route to the external network, as long as Router A remains up, it will continue to be the VRRP master even though traffic from the clients does not have a path to the external network. However, if the interface and/or route tracking features are configured, Router A can decrease its priority value when the problems occur so that Router B becomes the master. 1236 Configuring VRRP To configure Router A: 1 Enable routing for the switch. console#config console(config)#ip routing 2 Create and configure the VLAN routing interface to use as the default gateway for network clients. This example assumes all other routing interfaces, such as the interface to the external network, have been configured. console(config)#interface vlan 10 console(config-if-vlan10)#ip address 192.168.10.1 255.255.255.0 console(config-if-vlan10)#exit 3 Enable VRRP for the switch. console(config)#ip vrrp 4 Assign a virtual router ID to the VLAN routing interface for the VRRP group. console(config)#interface vlan 10 console(config-if-vlan10)#vrrp 10 5 Specify the IP address that the virtual router function will use. console(config-if-vlan10)#vrrp 10 ip 192.168.10.15 6 Configure the router priority. console(config-if-vlan10)#vrrp 10 priority 200 7 Enable preempt mode so that the router can regain its position as VRRP master if its priority is greater than the priority of the backup router. console(config-if-vlan10)#vrrp 10 preempt 8 Enable the VRRP groups on the interface. console(config-if-vlan10)#vrrp 10 mode console(config-if-vlan10)#exit 9 Track the routing interface VLAN 25 on VRID 10 so that if it goes down, the priority of VRID 10 on Router A is decreased by 10, which is the default decrement priority value. console(config-if-vlan10)#vrrp 10 track interface vlan 25 10 Track the route to the 192.168.200.0 network. If it becomes unavailable, the priority of VRID 10 on Router A is decreased by 10, which is the default decrement priority value. Configuring VRRP 1237 console(config-if-vlan10)#vrrp 10 track ip route 192.168.200.0/24 console(config-if-vlan10)#exit Router B is the backup router for VRID 10. The configured priority is 195. If the VLAN 25 routing interface or route to the external network on Router A go down, the priority of Router A will become 190 (or 180, if both the interface and router are down). Because the configured priority of Router B is greater than the actual priority of Router A, Router B will become the master for VRID 10. When VLAN 25 and the route to the external network are back up, the priority of Router A returns to 200, and it resumes its role as VRRP master. To configure Router B: 1 Enable routing for the switch. console#config console(config)#ip routing 2 Create and configure the VLAN routing interface to use as the default gateway for network clients. This example assumes all other routing interfaces, such as the interface to the external network, have been configured. console(config)#interface vlan 10 console(config-if-vlan10)#ip address 192.168.10.2 255.255.255.0 console(config-if-vlan10)#exit 3 Enable VRRP for the switch. console(config)#ip vrrp 4 Assign a virtual router ID to the VLAN routing interface for the VRRP group. console(config)#interface vlan 10 console(config-if-vlan10)#vrrp 10 5 Specify the IP address that the virtual router function will use. console(config-if-vlan10)#vrrp 10 ip 192.168.10.15 6 Configure the router priority. console(config-if-vlan10)#vrrp 10 priority 195 7 Enable preempt mode so that the router can regain its position as VRRP master if its priority is greater than the priority of the backup router. console(config-if-vlan10)#vrrp 10 preempt 1238 Configuring VRRP 8 Enable the VRRP groups on the interface. console(config-if-vlan10)#vrrp 10 mode console(config-if-vlan10)#exit console(config)#exit Configuring VRRP 1239 1240 Configuring VRRP Configuring IPv6 Routing 38 This chapter describes how to configure general IPv6 routing information on the switch, including global routing settings and IPv6 static routes. The topics covered in this chapter include: • IPv6 Routing Overview • Default IPv6 Routing Values • Configuring IPv6 Routing Features (Web) • Configuring IPv6 Routing Features (CLI) The Dell Networking series switches support additional features to help manage IPv6 networks, including OSPFv3, DHCPv6, and IPv6 multicast. For information about OSPFv3, see "Configuring OSPF and OSPFv3" on page 1111. For information about DHCPv6, see "Configuring DHCPv6 Server and Relay Settings" on page 1265. For information about IPv6 multicast, see "Managing IPv4 and IPv6 Multicast" on page 1337. For configuration examples that include IPv6 interface configuration, see "OSPF Configuration Examples" on page 1177 IPv6 Routing Overview IPv6 is the next generation of the Internet Protocol. With 128-bit addresses, versus 32-bit addresses for IPv4, IPv6 solves the address depletion issues seen with IPv4 and removes the requirement for Network Address Translation (NAT), which is used in IPv4 networks to reduce the number of globally unique IP addresses required for a given network. On the Dell Networking N2000, N3000, and N4000 series switches, IPv6 coexists with IPv4. As with IPv4, IPv6 routing can be enabled on loopback and VLAN interfaces. Each L3 routing interface can be used for IPv4, IPv6, or both. IP protocols running over L3 (for example, UDP and TCP) are common to both IPv4 and IPv6. Configuring IPv6 Routing 1241 How Does IPv6 Compare with IPv4? There are many conceptual similarities between IPv4 and IPv6 network operation. Addresses still have a network prefix portion (network) and a device interface specific portion (host). While the length of the network portion is still variable, most users have standardized on using a network prefix length of 64 bits. This leaves 64 bits for the interface specific portion, called an Interface ID in IPv6. Depending upon the underlying link addressing, the Interface ID can be automatically computed from the link (e.g., MAC address). Such an automatically computed Interface ID is called an EUI-64 identifier, which is the interface MAC address with ff:fe inserted in the middle. IPv6 packets on the network are of an entirely different format than traditional IPv4 packets and are also encapsulated in a different EtherType (86DD rather than 0800 which is used with IPv4). The details for encapsulating IPv6 in Ethernet frames are described in RFC2462. Unlike IPv4, IPv6 does not have broadcasts. There are two types of IPv6 addresses — unicast and multicast. Unicast addresses allow direct one-to-one communication between two hosts, whereas multicast addresses allow one-tomany communication. Multicast addresses are used as destinations only. Unicast addresses will have 00 through fe in the most significant octets and multicast addresses will have ff in the most significant octets. How Are IPv6 Interfaces Configured? In Dell Networking N2000, N3000, and N4000 series switches software, IPv6 coexists with IPv4. As with IPv4, IPv6 routing can be enabled on VLAN interfaces. Each L3 routing interface can be used for IPv4, IPv6, or both simultaneously. Neighbor Discovery (ND) protocol is the IPv6 replacement for Address Resolution Protocol (ARP) in IPv4. The IPv6 Neighbor Discovery protocol is described in detail in RFC4861. Router advertisement is part of the Neighbor Discovery process and is required for IPv6. As part of router advertisement, Dell Networking N2000, N3000, and N4000 series switches software supports stateless auto configuration of end nodes. The switch supports both EUI-64 interface identifiers and manually configured interface IDs. 1242 Configuring IPv6 Routing While optional in IPv4, router advertisement is mandatory in IPv6. Router advertisements specify the network prefix(es) on a link which can be used by receiving hosts, in conjunction with an EUI-64 identifier, to autoconfigure a host’s address. Routers have their network prefixes configured and may use EUI-64 or manually configured interface IDs. In addition to zero or more global addresses, each IPv6 interface also has an autoconfigured “link-local” address which is: • fe80::/10, with the EUI-64 address in the least significant bits. • Reachable only on the local VLAN — link-local addresses are never routed. • Not globally unique Next hop addresses computed by routing protocols are usually link-local addresses. During the period of transitioning the Internet to IPv6, a global IPv6 Internet backbone may not be available. One transition mechanism is to tunnel IPv6 packets inside IPv4 to reach remote IPv6 islands. When a packet is sent over such a link, it is encapsulated in IPv4 in order to traverse an IPv4 network and has the IPv4 headers removed at the other end of the tunnel. Default IPv6 Routing Values IPv6 is disabled by default on the switch and on all interfaces. Table 38-1 shows the default values for the IP routing features this chapter describes. Table 38-1. IPv6 Routing Defaults Parameter Default Value IPv6 Unicast Routing Mode Disabled IPv6 Hop Limit Unconfigured ICMPv6 Rate Limit Error Interval 1000 milliseconds ICMPv6 Rate Limit Burst Size 100 Interface IPv6 Mode Disabled Configuring IPv6 Routing 1243 Table 38-1. IPv6 Routing Defaults (Continued) Parameter Default Value IPv6 Router Route Preferences Local—0 Static—1 OSPFv3 Intra—110 OSPFv3 Inter—110 OSPFv3 External—110 Table 38-2 shows the default IPv6 interface values after a VLAN routing interface has been created. Table 38-2. IPv6 Interface Defaults Parameter Default Value IPv6 Mode Disabled DHCPv6 Client Mode Disabled Stateless Address AutoConfig Mode Disabled Routing Mode Enabled Interface Maximum Transmit Unit 1500 Router Duplicate Address Detection Transmits 1 Router Advertisement NS Interval Not configured Router Lifetime Interval 1800 seconds Router Advertisement Reachable Time 0 seconds Router Advertisement Interval 600 seconds Router Advertisement Managed Config Flag Disabled Router Advertisement Other Config Flag Disabled Router Advertisement Suppress Flag Disabled IPv6 Destination Unreachables Enabled 1244 Configuring IPv6 Routing Configuring IPv6 Routing Features (Web) This section provides information about the OpenManage Switch Administrator pages for configuring and monitoring IPv6 unicast routing features on a Dell Networking N2000, N3000, and N4000 series switches. For details about the fields on a page, click at the top of the page. Global Configuration Use the Global Configuration page to enable IPv6 forwarding on the router, enable the forwarding of IPv6 unicast datagrams, and configure global IPv6 settings. To display the page, click Routing → IPv6 → Global Configuration in the navigation panel. Figure 38-1. IPv6 Global Configuration Configuring IPv6 Routing 1245 Interface Configuration Use the Interface Configuration page to configure IPv6 interface parameters. This page has been updated to include the IPv6 Destination Unreachables field. To display the page, click Routing → IPv6 → Interface Configuration in the navigation panel. Figure 38-2. IPv6 Interface Configuration 1246 Configuring IPv6 Routing Interface Summary Use the Interface Summary page to display settings for all IPv6 interfaces. To display the page, click Routing → IPv6 → Interface Summary in the navigation panel. Figure 38-3. IPv6 Interface Summary Configuring IPv6 Routing 1247 IPv6 Statistics Use the IPv6 Statistics page to display IPv6 traffic statistics for one or all interfaces. To display the page, click Routing → IPv6 → IPv6 Statistics in the navigation panel. Figure 38-4. IPv6 Statistics 1248 Configuring IPv6 Routing IPv6 Neighbor Table Use the IPv6 Neighbor Table page to display IPv6 neighbor details for a specified interface. To display the page, click IPv6 → IPv6 Neighbor Table in the navigation panel. Figure 38-5. IPv6 Neighbor Table Configuring IPv6 Routing 1249 DHCPv6 Client Parameters Use the DHCPv6 Client Parameters page to view information about the network information automatically assigned to an interface by the DHCPv6 server. This page displays information only if the DHCPv6 client has been enabled on an IPv6 routing interface. To display the page, click Routing → IPv6 → DHCPv6 Client > Lease Parameters in the navigation panel. Figure 38-6. DHCPv6 Lease Parameters 1250 Configuring IPv6 Routing DHCPv6 Client Statistics Use the DHCPv6 Client Statistics page to view information about DHCPv6 packets received and transmitted on a DHCPv6 client interface. To display the page, click Routing → IPv6 → DHCPv6 Client > Statistics in the navigation panel. Figure 38-7. DHCPv6 Lease Parameters Configuring IPv6 Routing 1251 IPv6 Router Entry Configuration Use the IPv6 Route Entry Configuration page to configure information for IPv6 routes. To display the page, click Routing → IPv6 → IPv6 Routes → IPv6 Route Entry Configuration in the navigation panel. Figure 38-8. IPv6 Route Entry Configuration 1252 Configuring IPv6 Routing IPv6 Route Table Use the IPv6 Route Table page to display all active IPv6 routes and their settings. To display the page, click Routing → IPv6 → IPv6 Routes → IPv6 Route Table in the navigation panel. Figure 38-9. IPv6 Route Table Configuring IPv6 Routing 1253 IPv6 Route Preferences Use the IPv6 Route Preferences page to configure the default preference for each protocol. These values are arbitrary values in the range of 1 to 255 and are independent of route metrics. Most routing protocols use a route metric to determine the shortest path known to the protocol, independent of any other protocol. The best route to a destination is chosen by selecting the route with the lowest preference value. When there are multiple routes to a destination, the preference values are used to determine the preferred route. If there is still a tie, the route with the best route metric is chosen. To avoid problems with mismatched metrics, you must configure different preference values for each of the protocols. To display the page, click Routing → IPv6 → IPv6 Routes → IPv6 Route Preferences in the navigation panel. Figure 38-10. 1254 IPv6 Route Preferences Configuring IPv6 Routing Configured IPv6 Routes Use the Configured IPv6 Routes page to display selected IPv6 routes. NOTE: For a static reject route, the next hop interface value is Null0. Packets to the network address specified in static reject routes are intentionally dropped. To display the page, click Routing → IPv6 → IPv6 Routes → Configured IPv6 Routes in the navigation panel. Figure 38-11. Configured IPv6 Routes To remove a configured route, select the check box in the Delete column of the route to remove, and click Apply. Configuring IPv6 Routing 1255 Configuring IPv6 Routing Features (CLI) This section provides information about the commands you use to configure IPv6 routing on the switch. For more information about the commands, see the Dell Networking N2000, N3000, and N4000 Series Switches CLI Reference Guide at support.dell.com/manuals. Configuring Global IP Routing Settings Beginning in Privileged EXEC mode, use the following commands to configure various global IP routing settings for the switch. Command Purpose configure Enter global configuration mode. sdm prefer dual-ipv4and-ipv6 default Select a Switch Database Management (SDM) template to enable support for both IPv4 and IPv6. Changing the SDM template requires a system reload. ipv6 unicast-routing Globally enable IPv6 routing on the switch. ipv6 hop-limit limit Set the TTL value for the router. The valid range is 0 to 255. ipv6 icmp error-interval Limit the rate at which IPv4 ICMP error messages are sent. burst-interval [burstsize] • burst-interval — How often the token bucket is initialized (Range: 0–2147483647 milliseconds). • burst-size — The maximum number of messages that can be sent during a burst interval (Range: 1–200). exit 1256 Exit to Privileged EXEC mode. Configuring IPv6 Routing Configuring IPv6 Interface Settings Beginning in Privileged EXEC mode, use the following commands to configure IPv6 settings for VLAN, tunnel, or loopback interfaces. Command Purpose configure Enter Global Configuration mode. interface {vlan | tunnel | loopback} Enter Interface Configuration mode for the specified VLAN, tunnel, or loopback interface. ipv6 enable Enable IPv6 on the interface. Configuring an IPv6 address will automatically enable IPv6 on the interface. ipv6 address {autoconfig | dhcp | Configure the IPv6 address and network prefix length. Setting an IPv6 address enables IPv6 on the interface. You can also use the ipv6 enable command to enable IPv6 on the interface without setting an address. interface-id prefix/prefix-length [eui64]} Link-local, multicast, IPv4-compatible, and IPv4-mapped addresses are not allowed to be configured. Include the EUI-64 keyword to have the system add the 64bit interface ID to the address. You must use a network prefix length of 64 in this case. For VLAN interfaces, use the dhcp keyword to enable the DHCPv6 client and obtain an IP address form a network DHCPv6 server. ipv6 traffic-filter ACL Add an access-list filter to this interface. name ipv6 unreachables (VLAN interfaces only) Allow the interface to send ICMPv6 Destination Unreachable messages. The no ipv6 unreachables command suppresses the ICMPv6 unreachable messages for this interface. exit Exit the interface configuration mode. Configuring IPv6 Routing 1257 Configuring IPv6 Neighbor Discovery Use the following commands to configure IPv6 Neighbor Discovery settings. Command Purpose ipv6 nd prefix Configure parameters associated with network prefixes that the router advertises in its Neighbor Discovery advertisements. prefix/prefix-length [{valid-lifetime| infinite} {preferredlifetime| infinite}] [no-autoconfig] [offlink] • ipv6-prefix—IPv6 network prefix. • prefix-length—IPv6 network prefix length. • valid-lifetime—Valid lifetime of the router in seconds. (Range: 0–4294967295 seconds.) • infinite—Indicates lifetime value is infinite. • preferred-lifetime—Preferred-lifetime of the router in seconds. (Range: 0–4294967295 seconds.) • no-autoconfig—Do not use the prefix for auto configuration. • off-link—Do not use the prefix for onlink determination. ipv6 nd ra-interval maximum minimum Set the transmission interval between router Neighbor Discovery advertisements. • maximum — The maximum interval duration (Range: 4–1800 seconds). • minimum — The minimum interval duration (Range: 3 – (0.75 * maximum) seconds). ipv6 nd ra-lifetime seconds Set the value that is placed in the Router Lifetime field of the router Neighbor Discovery advertisements sent from the interface. The seconds value must be zero, or it must be an integer between the value of the router advertisement transmission interval and 9000 seconds. A value of zero means this router is not to be used as the default router. (Range: 0-9000). ipv6 nd suppress-ra Suppress router advertisement transmission on an interface. ipv6 nd dad attempts Set the number of duplicate address detection probes transmitted while doing Neighbor Discovery. value The range for value is 0–600. 1258 Configuring IPv6 Routing Command Purpose ipv6 nd ns-interval milliseconds Set the interval between router advertisements for advertised neighbor solicitations. The range is 1000 to 4294967295 milliseconds. ipv6 nd other-configflag Set the other stateful configuration flag in router advertisements sent from the interface. ipv6 nd managedconfig-flag Set the managed address configuration flag in router advertisements. When the value is true, end nodes use DHCPv6. When the value is false, end nodes automatically configure addresses. ipv6 nd reachabletime milliseconds Set the router advertisement time to consider a neighbor reachable after neighbor discovery confirmation. Configuring IPv6 Routing 1259 Configuring IPv6 Route Table Entries and Route Preferences Beginning in Privileged EXEC mode, use the following commands to configure IPv6 Static Routes. Command Purpose configure Enter global configuration mode. ipv6 route ipv6prefix/prefix-length {nexthop-address | interfacetype interface-number next-hop-address } [preference] Configure a static route.Use the keyword null instead of the next hop router IP address to configure a static reject route. • prefix/prefix-length—The IPv6 network prefix and prefix length that is the destination of the static route. Use the ::/0 form (unspecified address and zero length prefix) to specify a default route. • interface-type interface-number—Must be specified when using a link-local address as the next hop. The interface-type can be vlan or tunnel. • next-hop-address —The IPv6 address of the next hop that can be used to reach the specified network. A linklocal next hop address must have a prefix length of 128. The next hop address cannot be an unspecified address (all zeros), a multicast address, or a loopback address. If a link local next hop address is specified, the interface (VLAN or tunnel), must also be specified. • preference—Also known as Administrative Distance, a metric the router uses to compare this route with routes from other route sources that have the same network prefix. (Range: 1-255). Lower values have precedence over higher values. The default preference for static routes is 1. Routes with a preference of 255 are considered as “disabled” and will not be used for forwarding. Routes with a preference metric of 254 are used by the local router but will never be advertised to other neighboring routers. ipv6 route ipv6prefix/prefix-length null [preference] 1260 Configure a static reject route. IPv6 packets matching the reject route will be silently discarded. Configuring IPv6 Routing Command Purpose ipv6 route distance Set the default distance (preference) for static IPv6 routes. Lower route preference values are preferred when determining the best route. The default distance (preference) for static routes is 1. exit Exit to Global Config mode. integer Configuring IPv6 Routing 1261 IPv6 Show Commands Use the following commands in Privileged EXEC mode to view IPv6 configuration status and related data. Command Purpose show sdm prefer Show the currently active SDM template. show sdm prefer dualipv4-and-ipv6 default Show parameters for the SDM template. show ipv6 dhcp interface View information about the DHCPv6 lease acquired by vlan vlan-id the specified interface. show ipv6 interface {vlan View the IP interface configuration information for the | tunnel | loopback} specified IPv6 routing interface. interface-id show ipv6 brief View the global IPv6 settings for the switch. show ipv6 route [ipv6address | ipv6prefix/prefix-length | protocol | interface-type interface-number] [best] View the routing table. • ipv6-address—Specifies an IPv6 address for which the best-matching route would be displayed. • protocol—Specifies the protocol that installed the routes. Is one of the following keywords: connected, ospf, static. • ipv6-prefix/ prefix-length—Specifies an IPv6 network for which the matching route would be displayed. • interface-type interface-number—Valid IPv6 interface. Specifies that the routes with next-hops on the selected interface be displayed. • best—Specifies that only the best routes are displayed. If the connected keyword is selected for protocol, the best option is not available because there are no best or non-best connected routes. show ipv6 route summary View summary information about the IPv6 routing table. show ipv6 route preferences 1262 View detailed information about the IPv6 route preferences. Configuring IPv6 Routing IPv6 Static Reject and Discard Routes A static configured route with a next-hop of “null” causes any packet matching the route to disappear or vanish from the network. This type of route is called a “Discard” route if the router returns an ICMP “networkunreachable” message, or is called a “Reject” route if no ICMP message is returned. The Dell Networking series switches support “Reject” routes, where any packets matching the route network prefix silently disappear. A common use of a Reject route is to quickly discard packets that cannot be delivered because a valid route to the destination is not known. Without the Reject route, these undeliverable packets will continue to circulate through the network, following the default routes, until their TTL expires. Forwarding packets that cannot be delivered wastes bandwidth, particularly on expensive WAN connections. The Reject route will also suppress a type of “Denial of Service” (DoS) attack where an internal host sends large numbers of packets to unknown destinations, causing congestion of the WAN links. • ipv6 route ::/0 null 254 Use this in all routers except the ones with direct Internet connectivity. Routers with direct Internet connectivity should advertise a default route. The effect of this route is that when a router does not have connectivity to the Internet, the router will quickly discard packets that it cannot deliver. If the router learns a default route from another router, the learned route will have a lower distance metric and therefore a higher preference. Routes that are more specific (have more bits in the prefix) will have precedence over less specific routes. This will cause packets destined for non-existent networks to be quickly discarded. Also, because of the high distance metric (254), this route will never be advertised to any neighbor routers. • ipv6 route fc00::/7 null 254 This route covers the entire ULA (IPv6 private) address space. If you have networks configured in this address space, you will have more specific routes for those networks. The more specific routes (more bits of prefix) will have precedence over this route. Any destinations in this range not known via another, more specific route do not exist. The effect is that packets destined for private networks that do not exist in your network will be quickly discarded instead of being forwarded to the default route. Configuring IPv6 Routing 1263 • ipv6 route 2001::/16 null 254 ipv6 route 2002::/16 null 254 These address ranges are reserved and not reachable in the Internet. If for some reason you have local networks in this range, a more specific route will have precedence. Another use for the Reject route is to prevent internal hosts from communication with specific addresses or ranges of addresses. The effect is the same as an outgoing access-list with a “deny” statement. A route is generally more efficient than an access-list that performs the same function. If you need more fine-grained filtering, such as protocols or port numbers, use the access-list instead. 1264 Configuring IPv6 Routing 39 Configuring DHCPv6 Server and Relay Settings This chapter describes how to configure the switch to dynamically assign network information to IPv6 hosts by using the Dynamic Host Configuration Protocol for IPv6 (DHCPv6). The topics covered in this chapter include: • DHCPv6 Overview • Default DHCPv6 Server and Relay Values • Configuring the DHCPv6 Server and Relay (Web) • Configuring the DHCPv6 Server and Relay (CLI) • DHCPv6 Configuration Examples DHCPv6 Overview DHCP is a protocol that is generally used between clients and servers for the purpose of assigning IP addresses, gateways, and other networking definitions such as Domain Name System (DNS) and Network Time Protocol (NTP) parameters. However, IPv6 natively provides IP address auto configuration through IPv6 Neighbor Discovery Protocol (NDP) and through the use of Router Advertisement messages. Thus, the role of DHCPv6 within the network is different than that of DHCPv4 because DHCPv6 is not the primary source for IP address assignment. DHCPv6 server and client interactions are described by RFC 3315 [6]. There are many similarities between DHCPv6 and DHCPv4 interactions and options, but there are enough differences in the messages and option definitions that there is no DHCPv4 to DHCPv6 migration or interoperability. Configuring DHCPv6 Server and Relay Settings 1265 What Is a DHCPv6 Pool? DHCPv6 pools are used to specify information for DHCPv6 server to distribute to DHCPv6 clients. These pools are shared between multiple interfaces over which DHCPv6 server capabilities are configured. What Is a Stateless Server? DHCPv6 incorporates the notion of the stateless server, where DHCPv6 is not used for IP address assignment to a client; rather, it provides other networking information such as DNS or NTP information. The stateless server behavior is described by RFC 3736 [7], which simply contains descriptions of the portions of RFC 3315 that are necessary for stateless server behavior. In order for a router to drive a DHCPv6 client to utilize stateless DHCPv6, the other stateful configuration option must be configured for neighbor discovery on the corresponding IPv6 router interface. This, in turn, causes DHCPv6 clients to send the DHCPv6 Information Request message in response. A DHCPv6 server then responds by providing only networking definitions such as DNS domain name and server definitions, NTP server definitions, or SIP definitions. What Is the DHCPv6 Relay Agent Information Option? The DHCPv6 Relay Agent Information Option allows for various sub-options to be attached to messages that are being relayed by the local router to a DHCPv6 server. The DHCPv6+ server may in turn use this information in determining an address to assign to a DHCPv6 client.RFC 3315 also describes DHCPv6 Relay Agent interactions, which are very much like DHCPv4 Relay Agents. Additionally, there is a DHCPv6 Relay Agent Option described in RFC 4649, which employs very similar capabilities as those described by the DHCPv4 Relay Agent Option in RFC 2132. What Is a Prefix Delegation? With the larger address space inherent to IPv6, addresses within a network can be allocated more effectively in a hierarchical fashion. DHCPv6 introduces the notion of prefix delegation as described in RFC 3633 as a way for routers to centralize and delegate IP address assignment. Figure 39-1 depicts a typical network scenario where prefix delegation is used. 1266 Configuring DHCPv6 Server and Relay Settings Figure 39-1. DHCPv6 Prefix Delegation Scenario In Figure 39-1, the Dell Networking acts as the Prefix Delegation (PD) server and defines one or more general prefixes to allocate and assign addresses to hosts that may be utilizing IPv6 auto-address configuration or acting as DHCPv6 clients. DHCPv6 clients may request multiple IPv6 prefixes. Also, DHCPv6 clients may request specific IPv6 prefixes. If the configured DHCPv6 pool contains the specific prefix that a DHCPv6 client requests, then that prefix will be delegated to the client. Otherwise, the first available IPv6 prefix within the configured pool will be delegated to the client. Default DHCPv6 Server and Relay Values By default, the DHCPv6 server is disabled, and no address pools are configured. VLAN routing interfaces are not configured to perform DHCPv6 server or DHCPv6 relay functions. Configuring DHCPv6 Server and Relay Settings 1267 Configuring the DHCPv6 Server and Relay (Web) This section provides information about the OpenManage Switch Administrator pages for configuring and monitoring the DHCPv6 server on a Dell Networking N2000, N3000, and N4000 series switches. For details about the fields on a page, click at the top of the page. DHCPv6 Global Configuration Use the Global Configuration page to configure DHCPv6 global parameters. To display the page, click Routing → IPv6 → DHCPv6 Server → Global Configuration in the navigation panel. Figure 39-2. DHCPv6 Global Configuration 1268 Configuring DHCPv6 Server and Relay Settings DHCPv6 Pool Configuration Use the Pool Configuration page to set up a pool of DHCPv6 parameters for DHCPv6 clients. The pool is identified with a pool name and contains IPv6 addresses and domain names of DNS servers. To display the page, click Routing → IPv6 → DHCPv6 → Pool Configuration in the navigation panel. Figure 39-3 shows the page when no pools have been created. After a pool has been created, additional fields display. Figure 39-3. Pool Configuration Configuring a DHCPv6 Pool To configure the pool: 1 Open the Pool Configuration page. 2 Select Create from the Pool Name menu and type a name in the Pool Name text box. 3 Click Apply. Configuring DHCPv6 Server and Relay Settings 1269 Figure 39-4. Pool Configuration 4 From the DNS Server Address menu, select an existing DNS Server Address to associate with this pool, or select Add and specify a new server to add. 5 From the Domain Name menu, select an existing domain name to associate with this pool, or select Add and specify a new domain name. 6 Click Apply. 1270 Configuring DHCPv6 Server and Relay Settings Prefix Delegation Configuration Use the Prefix Delegation Configuration page to configure a delegated prefix for a pool. At least one pool must be created using DHCPv6 Pool Configuration before a delegated prefix can be configured. To display the page, click Routing → IPv6 → DHCPv6 → Prefix Delegation Configuration in the navigation panel. Figure 39-5. Prefix Delegation Configuration Configuring DHCPv6 Server and Relay Settings 1271 DHCPv6 Pool Summary Use the Pool Summary page to display settings for all DHCPv6 Pools. At least one pool must be created using DHCPv6 Pool Configuration before the Pool Summary displays. To display the page, click Routing → IPv6 → DHCPv6 → Pool Summary in the navigation panel. Figure 39-6. Pool Summary 1272 Configuring DHCPv6 Server and Relay Settings DHCPv6 Interface Configuration Use the DHCPv6 Interface Configuration page to configure a DHCPv6 interface. To display the page, click Routing → IPv6 → DHCPv6 → Interface Configuration in the navigation panel. The fields that display on the page depend on the selected interface mode. Figure 39-7. DHCPv6 Interface Configuration Configuring DHCPv6 Server and Relay Settings 1273 Figure 39-8 shows the screen when the selected interface mode is Server. Figure 39-8. DHCPv6 Interface Configuration - Server Mode Figure 39-9 shows the screen when the selected interface mode is Relay. Figure 39-9. DHCPv6 Interface Configuration - Relay Mode 1274 Configuring DHCPv6 Server and Relay Settings DHCPv6 Server Bindings Summary Use the Server Bindings Summary page to display all DHCPv6 server bindings. To display the page, click Routing → IPv6 → DHCPv6 → Bindings Summary in the navigation panel. Figure 39-10. Server Bindings Summary Configuring DHCPv6 Server and Relay Settings 1275 DHCPv6 Statistics Use the DHCPv6 Statistics page to display DHCPv6 statistics for one or all interfaces. To display the page, click Routing → IPv6 → DHCPv6 → Statistics in the navigation panel. Figure 39-11. 1276 DHCPv6 Statistics Configuring DHCPv6 Server and Relay Settings Configuring the DHCPv6 Server and Relay (CLI) This section provides information about the commands you use to configure and monitor the DHCP server and address pools. For more information about the commands, see the Dell Networking N2000, N3000, and N4000 Series Switches CLI Reference Guide at support.dell.com/manuals. Configuring Global DHCP Server and Relay Agent Settings Beginning in Privileged EXEC mode, use the following commands to configure settings for the DHCPv6 server. Command Purpose configure Enter Global Configuration mode. service dhcpv6 Enable the DHCPv6 server. ipv6 dhcp relay-agentinfo-opt option Configure a number to represent the DHCPv6 Relay Agent Information Option. The option parameter is an integer from 54–65535. ipv6 dhcp relay-agentinfo-remote-id-subopt suboption Configure a number to represent the DHCPv6 remote-ID sub-option The suboption parameter is an integer from 1–65535. exit Exit to Privileged EXEC mode. show ipv6 dhcp Verify the global DHCPv6 server configuration. Configuring a DHCPv6 Pool for Stateless Server Support Beginning in Privileged EXEC mode, use the following commands to create a pool and configure pool parameters for DHCPv6 clients that obtain IPv6 network information dynamically. Command Purpose configure Enter Global Configuration mode. ipv6 dhcp pool name Create a DHCPv6 pool and enter DHCPv6 pool configuration mode. dns-server ipv6-address Set up to eight IPv6 DNS server addresses to provide to a DHCPv6 client by the DHCPv6 server. Configuring DHCPv6 Server and Relay Settings 1277 Command Purpose domain-name domain Set up to five DNS domain names to provide to a DHCPv6 client by the DHCPv6 server. CTRL + Z Exit to Privileged EXEC mode. show ipv6 dhcp pool [name] View the settings for all DHCPv6 pools or for the specified pool. Configuring a DHCPv6 Pool for Specific Hosts Beginning in Privileged EXEC mode, use the following commands to create a pool and/or configure pool parameters for specific DHCPv6 clients. Command Purpose configure Enter Global Configuration mode. ipv6 dhcp pool name Create a DHCPv6 pool and enter DHCPv6 pool configuration mode. prefix-delegation ipv6prefix/prefix-length client-DUID [name hostname] [validlifetime {valid-lifetime | Define an IPv6 prefixes within a pool for distributing to specific DHCPv6 Prefix delegation clients. infinite}] [preferredlifetime {preferredlifetime | infinite}] • prefix/prefix-length—Delegated IPv6 prefix. • client-DUID—DHCP Unique Identifier for the client (e.g. 00:01:00:09:f8:79:4e:00:04:76:73:43:76'). • hostname—Client hostname used for logging and tracing. (Range: 0-31 characters.) The command allows spaces in the host name. • valid-lifetime—Valid lifetime for delegated prefix. (Range: 0-4294967295 seconds) or use the keyword infinite. • preferred-lifetime—Preferred lifetime for delegated prefix. (Range: 0-4294967295 seconds) or use the keyword infinite. CTRL + Z Exit to Privileged EXEC mode. show ipv6 dhcp pool View information about the DHCPv6 pools configured on the switch. 1278 Configuring DHCPv6 Server and Relay Settings Configuring DHCPv6 Interface Information Beginning in Privileged EXEC mode, use the following commands to configure an interface as a DHCPv6 server or a DHCPv6 relay agent. The server and relay functionality are mutually exclusive. In other words, a VLAN routing interface can be configured as a DHCPv6 server or a DHCPv6 relay agent, but not both. Command Purpose configure Enter Global Configuration mode. Enter interface configuration mode for a tunnel or VLAN interface {tunnel tunnel-id | vlan vlan-id} routing interface to configure as a DHCPv6 relay agent. ipv6 dhcp relay Configure the interface for DHCPv6 relay functionality. {destination relay• destination — Keyword that sets the relay server IPv6 address [interface vlan address. vlan-id] | interface vlan • relay-address — An IPv6 address of a DHCPv6 relay vlan-id} [remote-id server. {duid-ifid | userdefined-string}] • interface — Sets the relay server interface. • vlan-id — A valid VLAN ID. • [remote-id {duid-ifid | user-defined-string}] — The Relay Agent Information Option “remote ID” sub-option to be added to relayed messages. This can either be the special keyword duid-ifid, which causes the “remote ID” to be derived from the DHCPv6 server DUID and the relay interface number, or it can be specified as a userdefined string. exit Exit to Global Configuration Mode interface {tunnel Enter interface configuration mode for a tunnel or VLAN tunnel-id | vlan vlan-id} routing interface to configure with DHCPv6 server functionality. Configuring DHCPv6 Server and Relay Settings 1279 Command Purpose ipv6 dhcp server poolname [rapid-commit] [preference pref-value] Configure DHCPv6 server functionality on the interface. • pool-name — The name of the DHCPv6 pool containing stateless and/or prefix delegation parameters • rapid-commit — Is an option that allows for an abbreviated exchange between the client and server. • pref-value — Preference value—used by clients to determine preference between multiple DHCPv6 servers. (Range: 0-4294967295) CTRL + Z Exit to Privileged Exec Mode. show ipv6 dhcp interface View DHCPv6 information for all interfaces or for the [tunnel tunnel-id | vlan specified interface. vlan-id] Monitoring DHCPv6 Information Beginning in Privileged EXEC mode, use the following commands to view bindings, and statistics, and to clear the information. Command Purpose show ipv6 dhcp binding View the current binding information in the DHCP server database. Specify the IP address to view a specific binding. [address] show ipv6 dhcp statistics View DHCPv6 server and relay agent statistics. clear ipv6 dhcp statistics Reset all DHCPv6 server and relay agent statistics to zero. 1280 Configuring DHCPv6 Server and Relay Settings DHCPv6 Configuration Examples This section contains the following examples: • Configuring a DHCPv6 Stateless Server • Configuring the DHCPv6 Server for Prefix Delegation • Configuring an Interface as a DHCPv6 Relay Agent Configuring a DHCPv6 Stateless Server This example configures a DHCPv6 pool that will provide information for the DHCPv6 server to distribute to DHCPv6 clients that are members of VLAN 100. To define stateless information for the DHCPv6 server to distribute, multiple DNS domain names and DNS server addresses are defined within the pool. VLAN routing interface 100 is configured as a DHCPv6 server. Setting NDP on the interface to send the other-config-flag option allows the interface to prompt DHCPv6 clients to request only stateless server information. To configure the switch: 1 Enable the DHCPv6 feature. console#configure console(config)#service dhcpv6 2 Create the DHCPv6 pool and configure stateless information. console(config)#ipv6 dhcp pool my-pool console(config-dhcp6s-pool)#domain-name pengo.dell.com console(config-dhcp6s-pool)#domain-name dell.com console(config-dhcp6s-pool)#dns-server 2001:DB8:A328:22C::1 console(config-dhcp6s-pool)#dns-server 2001:DB8:A328:22C::2 3 Configure VLAN 100 as a routing interface and assign an IPv6 address. console(config)#interface vlan 100 console(config-if-vlan100)#ipv6 address 2001:DB8:A328:34B::/32 Configuring DHCPv6 Server and Relay Settings 1281 4 Configure the DHCPv6 server functionality on VLAN 100. Clients can use the preference value to determine which DHCPv6 server to use when multiple servers exist. console(config-if-vlan100)#ipv6 dhcp server mypool preference 10 console(config-if-vlan100)#ipv6 nd other-configflag console(config-if-vlan100)#exit Configuring the DHCPv6 Server for Prefix Delegation In this example, VLAN routing interface 200 is configured to delegate specific prefixes to certain DHCPv6 clients. The prefix-to-DUID mapping is defined within the DHCPv6 pool. To configure the switch: 1 Create the DHCPv6 pool and specify the domain name and DNS server information. console(config)#ipv6 dhcp pool my-pool2 console(config-dhcp6s-pool)#domain-name dell.com console(config-dhcp6s-pool)#dns-server 2001:DB8:A328:22C::1 2 Specify the prefix delegations for specific clients. The first two commands provide multiple prefixes to the same client. console(config-dhcp6s-pool)#prefix-delegation 2001:DB8:1000::/32 00:01:00:09:f8:79:4e:00:04:76:73:43:76 validlifetime 600 preferred-lifetime 400 console(config-dhcp6s-pool)#prefix-delegation 2001:DB8:1001::/32 00:01:00:09:f8:79:4e:00:04:76:73:43:76 validlifetime 600 preferred-lifetime 400 1282 Configuring DHCPv6 Server and Relay Settings console(config-dhcp6s-pool)#prefix-delegation 2001:DB8:1002::/32 00:01:00:09:f8:79:4e:00:04:76:73:43:76 validlifetime 600 preferred-lifetime 400 console(config-dhcp6s-pool)#exit 3 Configure the DHCPv6 server functionality on VLAN 200 and specify the pool to use for DHCPv6 clients. console(config)#interface vlan 200 console(config-if-vlan200)#ipv6 dhcp server mypool2 preference 20 Configuring an Interface as a DHCPv6 Relay Agent This example configures a VLAN routing interface as a DHCPv6 Relay. The command defines the destination address of the relay server and the interface used for reachability to the relay server. To configure the switch: 1 Create VLAN 300 and define its IPv6 address. console(config)#interface vlan 300 console(config-if-vlan300)#ipv6 address 2001:DB8:03a::/64 2 Configure the interface as a DHCPv6 relay agent and specify the IPv6 address of the relay server. The command also specifies that the route to the server is through the VLAN 100 routing interface. console(config-if-vlan300)#ipv6 dhcp relay destination FE80::250:A2FF:FEBF:A056 interface vlan 100 console(config-if-vlan300)#exit console(config)#exit 3 View the DHCPv6 configuration for VLAN 300. console#show ipv6 dhcp interface vlan 300 IPv6 Interface.......................... ...Vl300 Mode....................................... Relay Relay Address........... FE80::250:A2FF:FEBF:A056 Configuring DHCPv6 Server and Relay Settings 1283 Relay Interface Number.....................Vl100 Relay Remote ID............................ Option Flags............................... 1284 Configuring DHCPv6 Server and Relay Settings 40 Configuring Differentiated Services This chapter describes how to configure the Differentiated Services (DiffServ) feature. DiffServ enables traffic to be classified into streams and given certain QoS treatment in accordance with defined per-hop behaviors. The topics covered in this chapter include: • DiffServ Overview • Default DiffServ Values • Configuring DiffServ (Web) • Configuring DiffServ (CLI) • DiffServ Configuration Examples DiffServ Overview Standard IP-based networks are designed to provide “best effort” data delivery service. Best effort service implies that the network delivers the data in a timely fashion, although there is no guarantee that it will. During times of congestion, packets may be delayed, sent sporadically, or dropped. For typical Internet applications, such as email and file transfer, a slight degradation in service is acceptable and in many cases unnoticeable. Conversely, any degradation of service has undesirable effects on applications with strict timing requirements, such as voice or multimedia. Configuring Differentiated Services 1285 How Does DiffServ Functionality Vary Based on the Role of the Switch? How you configure DiffServ support in Dell Networking N2000, N3000, and N4000 series switches software varies depending on the role of the switch in your network: • Edge device: An edge device handles ingress traffic, flowing towards the core of the network, and egress traffic, flowing away from the core. An edge device segregates inbound traffic into a small set of traffic classes, and is responsible for determining a packet’s classification. Classification is primarily based on the contents of the Layer 3 and Layer 4 headers, and is recorded in the Differentiated Services Code Point (DSCP) added to a packet’s IP header. • Interior node: A switch in the core of the network is responsible for forwarding packets, rather than for classifying them. It decodes the DSCP in an incoming packet, and provides buffering and forwarding services using the appropriate queue management algorithms. Before configuring DiffServ on Dell Networking series switches, you must determine the QoS requirements for the network as a whole. The requirements are expressed in terms of rules, which are used to classify inbound or outbound traffic on a particular interface. What Are the Elements of DiffServ Configuration? During configuration, you define DiffServ rules in terms of classes, policies, and services: • Class: A class consists of a set of rules that identify which packets belong to the class. Inbound traffic is separated into traffic classes based on Layer 2, Layer 3, and Layer 4 header data. The class type All is supported; this specifies that every match criterion defined for the class must be true for a match to occur. • Policy: A policy defines the QoS attributes for one or more traffic classes. An attribute identifies the action taken when a packet matches a class rule. An example of an attribute is to mark a packet. The switch supports the ability to assign traffic classes to output CoS queues, and to mirror incoming packets in a traffic stream to a specific egress interface (physical port or LAG). 1286 Configuring Differentiated Services Dell Networking N2000, N3000, and N4000 series switches software supports the Traffic Conditioning Policy type which is associated with an inbound traffic class and specifies the actions to be performed on packets meeting the class rules: • – Marking the packet with a given DSCP, IP precedence, or CoS value. Traffic to be processed by the DiffServ feature requires an IP header if the system uses IP Precedence or IP DSCP marking. – Policing packets by dropping or re-marking those that exceed the class’s assigned data rate. – Counting the traffic within the class. Service: Assigns a policy to an interface for inbound traffic. NOTE: You can use an 802.1X authenticator or RADIUS server to dynamically assign DiffServ filters to ports when a host connects to a port and authenticates by using 802.1X. For more information, see "How Does the Authentication Server Assign DiffServ Filters?" on page 511 Default DiffServ Values Table 40-1 shows the global default values for DiffServ. Table 40-1. DiffServ Global Defaults Parameter Default Value DiffServ Enabled Classes None configured Policies None configured Services None configured Configuring Differentiated Services 1287 Configuring DiffServ (Web) This section provides information about the OpenManage Switch Administrator pages for configuring and monitoring DiffServ features on a Dell Networking N2000, N3000, and N4000 series switches. For details about the fields on a page, click at the top of the page. DiffServ Configuration Use the DiffServ Configuration page to display the DiffServ administrative mode setting as well as the current and maximum number of rows in each of the main DiffServ private MIB tables. To display the page, click Quality of Service → Differentiated Services → DiffServ Configuration in the navigation panel. Figure 40-1. DiffServ Configuration 1288 Configuring Differentiated Services Class Configuration Use the DiffServ Class Configuration page to add a new DiffServ class name, or to rename or delete an existing class. To display the page, click Quality of Service → Differentiated Services → Class Configuration in the navigation panel. Figure 40-2. DiffServ Class Configuration Adding a DiffServ Class To add a DiffServ class: 1 From the DiffServ Class Configuration page, click Add to display the Add Class page. Figure 40-3. Add DiffServ Class Configuring Differentiated Services 1289 2 Enter a name for the class and select the protocol to use for class match criteria. 3 Click Apply to add the new class. 4 To view a summary of the classes configured on the switch, click Show All. Figure 40-4. View DiffServ Class Summary Class Criteria Use the DiffServ Class Criteria page to define the criteria to associate with a DiffServ class. As packets are received, these DiffServ classes are used to identify packets. To display the page, click Quality of Service → Differentiated Services → Class Criteria in the navigation panel. 1290 Configuring Differentiated Services Figure 40-5. DiffServ Class Criteria Configuring Differentiated Services 1291 Policy Configuration Use the DiffServ Policy Configuration page to associate a collection of classes with one or more policy statements. To display the page, click Quality of Service → Differentiated Services → Policy Configuration in the navigation panel. Figure 40-6. DiffServ Policy Configuration Adding a New Policy Name To add a policy: 1 From the DiffServ Policy Configuration page, click Add to display the Add Policy page. 1292 Configuring Differentiated Services Figure 40-7. Add DiffServ Policy 2 Enter the new Policy Name. 3 Click Apply to save the new policy. 4 To view a summary of the policies configured on the switch, click Show All. Figure 40-8. View DiffServ Policies Configuring Differentiated Services 1293 Policy Class Definition Use the DiffServ Policy Class Definition page to associate a class to a policy, and to define attributes for that policy-class instance. To display the page, click Quality of Service → Differentiated Services → Policy Class Definition in the navigation panel. Figure 40-9. DiffServ Policy Class Definition To view a summary of the policy attributes, click Show All. 1294 Configuring Differentiated Services Figure 40-10. Policy Class Definition Packet Marking Traffic Condition Follow these steps to have packets that match the class criteria for this policy marked with a marked with either an IP DSCP, IP precedence, or CoS value: 1 Select Marking from the Traffic Conditioning drop-down menu on the DiffServ Policy Class Definition page. The Packet Marking page displays. Figure 40-11. Policy Class Definition - Attributes 2 Select IP DSCP, IP Precedence, or Class of Service to mark for this policyclass. 3 Select or enter a value for this field. 4 Click Apply to define the policy-class. Configuring Differentiated Services 1295 Policing Traffic Condition Follow these steps to perform policing on the packets that match this policy class: 1 Select Policing from the Traffic Conditioning drop-down menu on the DiffServ Policy Class Definition page to display the DiffServ Policy Policing page. Figure 40-12. Policy Class Definition - Policing The DiffServ Policy - Policing page displays the Policy Name, Class Name, and Policing Style. Select a value for the following fields: • Color Mode — The type of color policing used: Color Blind or Color Aware. • Conform Action Selector — The action taken on packets that are considered conforming (below the police rate). Options are Send, Drop, Mark CoS, Mark IP DSCP, Mark IP Precedence. • Violate Action — The action taken on packets that are considered non-conforming (above the police rate). Options are Send, Drop, Mark CoS, Mark IP DSCP, Mark IP Precedence. 2 Click Apply. The policy-class is defined, and the device is updated. 1296 Configuring Differentiated Services Service Configuration Use the DiffServ Service Configuration page to activate a policy on a port. To display the page, click Quality of Service → Differentiated Services → Service Configuration in the navigation panel. Figure 40-13. DiffServ Service Configuration To view a summary of the services configured on the switch, click Show All. Figure 40-14. DiffServ Service Summary Configuring Differentiated Services 1297 Service Detailed Statistics Use the DiffServ Service Detailed Statistics page to display packet details for a particular port and class. To display the page, click Quality of Service → Differentiated Services → Service Detailed Statistics in the navigation panel. Figure 40-15. 1298 DiffServ Service Detailed Statistics Configuring Differentiated Services Flow-Based Mirroring Use the Flow-Based Mirroring page to create a mirroring session in which the traffic that matches the specified policy and member class is mirrored to a destination port. To display the Flow-Based Mirroring page, click Switching → Ports → Traffic Mirroring → Flow-Based Mirroring in the navigation panel. Figure 40-16. Flow-Based Mirroring Configuring Differentiated Services 1299 Configuring DiffServ (CLI) This section provides information about the commands you use to configure DiffServ settings on the switch. For more information about the commands, see the Dell Networking N2000, N3000, and N4000 Series Switches CLI Reference Guide at support.dell.com/manuals. DiffServ Configuration (Global) Beginning in Privileged Exec mode, use the following commands in to configure the global DiffServ mode and view related settings. CLI Command Description configure Enter global configuration mode. diffserv Set the DiffServ operational mode to active. exit Exit to Privileged EXEC mode. show diffserv Display the DiffServ general information, which includes the current administrative mode setting as well as the current and maximum number of DiffServ components. DiffServ Class Configuration for IPv4 Beginning in Privileged Exec mode, use the following commands to configure DiffServ classes for IPv4 and view related information. CLI Command Description configure Enter global configuration mode. class-map match-all class-map- Define a new DiffServ class and enter Class-Map name Configuration mode for the specified class. NOTE: To enter Class-Map Configuration mode for a class that has already been created, use the classmap class-map-name command. match any Configure a match condition for all the packets. match class-map Add to the specified class definition the set of match conditions defined for another class. 1300 Configuring Differentiated Services CLI Command Description match cos Add to the specified class definition a match condition for the Class of Service value. match destination-address mac Add to the specified class definition a match condition based on the destination MAC address of a packet. match dstip Add to the specified class definition a match condition based on the destination IP address of a packet. match dstl4port Add to the specified class definition a match condition based on the destination layer 4 port of a packet using a single keyword, or a numeric notation. match ethertype Add to the specified class definition a match condition based on the value of the ethertype. match ip dscp Add to the specified class definition a match condition based on the value of the IP DiffServ Code Point (DSCP) field in a packet. match ip precedence Add to the specified class definition a match condition based on the value of the IP. match ip tos Add to the specified class definition a match condition based on the value of the IP TOS field in a packet. match protocol Add to the specified class definition a match condition based on the value of the IP Protocol field in a packet using a single keyword notation or a numeric value notation. match secondary-cos Configure a match condition based on a secondary COS value. match secondary-vlan Configure a match condition based on a secondary VLAN value. match source-address mac Add to the specified class definition a match condition based on the source MAC address of the packet. Configuring Differentiated Services 1301 CLI Command Description match srcip Add to the specified class definition a match condition based on the source IP address of a packet. match srcl4port Add to the specified class definition a match condition based on the source layer 4 port of a packet using a single keyword, a numeric notation, or a numeric range notation. match vlan Add to the specified class definition a match condition based on the value of the layer 2 VLAN Identifier field. DiffServ Class Configuration for IPv6 Beginning in Privileged Exec mode, use the following commands to configure DiffServ classes for IPv6 and view related information. CLI Command Description configure Enter global configuration mode. class-map match-all class-map- Define a new DiffServ class. name ipv6 match any Configure a match condition for all the packets. match class-map Add to the specified class definition the set of match conditions defined for another class. match dstip6 Add to the specified class definition a match condition based on the destination IPv6 address of a packet. match dstl4port Add to the specified class definition a match condition based on the destination layer 4 port of a packet using a single keyword, or a numeric notation. match ip6flowlbl Add to the specified class definition a match condition based on the IPv6 flow label of a packet. match ip dscp Add to the specified class definition a match condition based on the value of the IP DiffServ Code Point (DSCP) field in a packet. 1302 Configuring Differentiated Services CLI Command Description match protocol Add to the specified class definition a match condition based on the value of the IP Protocol field in a packet using a single keyword notation or a numeric value notation. match source-address mac Add to the specified class definition a match condition based on the source MAC address of the packet. match srcip6 Add to the specified class definition a match condition based on the source IPv6 address of a packet. match srcl4port Add to the specified class definition a match condition based on the source layer 4 port of a packet using a single keyword, a numeric notation, or a numeric range notation. DiffServ Policy Creation Beginning in Privileged Exec mode, use the following commands to configure DiffServ policies and view related information. CLI Command Description configure Enter global configuration mode. policy-map policy-name in Create a new DiffServ policy for ingress traffic and enter Policy Map Configuration mode for the policy. exit Exit to Privilege Exec mode. show policy-map Displays all configuration information for the specified policy. show policy-map interface in Displays policy-oriented statistics information for the specified interface. Configuring Differentiated Services 1303 DiffServ Policy Attributes Configuration Beginning in Privilege Exec mode, use the following commands to configure policy attributes and view related information. CLI Command Description configure Enter global configuration mode. policy-map policy-map-name Enter Policy Map Configuration mode for the specified policy. class class-name Create an instance of a class definition within the specified policy for the purpose of defining treatment of the traffic class through subsequent policy attribute statements. Also enters PolicyClass-Map Configuration mode for the policy-classmap instance. assign-queue queue-id Modify the queue ID (range: 0–6) to which the associated traffic stream is assigned. police-simple {datarate burstsize conform-action {drop | set-cos-transmit cos | set-prectransmit cos | set-dscptransmit dscpval | transmit} [violateaction {drop | set-costransmit cos | set-prectransmit cos | set-dscptransmit dscpval | transmit}]} Establish the traffic policing style for the specified class. The simple form of the police command uses a single data rate and burst size, resulting in two outcomes: conform and nonconform. • datarate — Data rate in kilobits per second (kbps). (Range: 1–4294967295) • burstsize — Burst size in Kbps (Range: 1–128) • conform action — Indicates what happens when the packet is conforming to the policing rule: it could be dropped, it could have its COS modified, it could have its IP precedence modified, or it could have its DSCP modified. The same actions are available for packets that do not conform to the policing rule. • cos — Class of Service value. (Range: 0–7) • dscpval — DSCP value. (Range: 0–63 or a keyword from this list, af11, af12, af13, af21, af22, af23, af31, af32, af33, af41, af42, af43, be, cs0, cs1, cs2, cs3, cs4, cs5, cs6, cs7, ef) 1304 Configuring Differentiated Services CLI Command Description conform-color class-map-name Specify the color class for color-aware policing. [exceed-color class-map-name] The action for the policy-class-map instance must be set to police-simple before issuing the conformcolor command. drop Specify that all packets for the associated traffic stream are to be dropped at ingress. mark cos cos-value Mark all packets for the associated traffic stream with the specified class of service value (range: 0–7) in the priority field of the 802.1p header. mark ip-dscp dscp-value Mark all packets for the associated traffic stream with the specified IP DSCP value. mark ip-precedence value Mark all packets for the associated traffic stream with the specified IP precedence value (range: 0–7). mirror interface | redirect Use mirror to mirror all packets for the associated traffic stream that matches the defined class to the specified destination port or LAG. interface Use redirect to specify that all incoming packets for the associated traffic stream are redirected to the specified destination port or LAG. exit Exit to Policy-Map Config mode. exit Exit to Global Config mode. exit Exit to Privilege Exec mode. show policy-map policy-map- Displays configuration information for the specified policy. name Configuring Differentiated Services 1305 DiffServ Service Configuration Beginning Privilege Exec mode, use the following commands to associate a policy with an interface and view related information. CLI Command Description configure Enter Global Configuration mode. service-policy {in | out} policy-map-name Attach a policy to an interface in the inbound or outbound direction. This command can be used in either Global Configuration mode (for all system interfaces) or Interface Configuration mode (for a specific interface). exit Exit to Privilege Exec mode. show diffserv service brief [in | out] Display all interfaces in the system to which a DiffServ policy has been attached. show diffserv service interface interface {in | out} Display policy service information for the specified interface, where interface is replaced by gigabitethernet unit/slot/port, tengigabitethernet unit/slot/port, or port-channel portchannel number. show service-policy {in | out} Display a summary of policy-oriented statistics information for all interfaces. 1306 Configuring Differentiated Services DiffServ Configuration Examples This section contains the following examples: • Providing Subnets Equal Access to External Network • DiffServ for VoIP Providing Subnets Equal Access to External Network This example shows how a network administrator can provide equal access to the Internet (or other external network) to different departments within a company. Each of four departments has its own Class B subnet that is allocated 25% of the available bandwidth on the port accessing the Internet. Figure 40-17. DiffServ Internet Access Example Network Diagram Internet Port 1/0/5 Outbound Source IP: 172.16.10.0 255.255.255.0 Layer 3 Switch 1/0/1 1/0/2 1/0/3 Finance 1/0/4 Development Marketing Source IP: 172.16.20.0 255.255.255.0 Test Source IP: 172.16.40.0 255.255.255.0 Source IP: 172.16.30.0 255.255.255.0 Configuring Differentiated Services 1307 The following commands show how to configure the DiffServ example depicted in Figure 40-17. 1 Enable DiffServ operation for the switch. console#config console(config)#diffserv 2 Create a DiffServ class of type all for each of the departments, and name them. Also, define the match criteria—Source IP address—for the new classes. console(config)#class-map match-all finance_dept console(config-classmap)#match srcip 172.16.10.0 255.255.255.0 console(config-classmap)#exit console(config)#class-map match-all marketing_dept console(config-classmap)#match srcip 172.16.20.0 255.255.255.0 console(config-classmap)#exit console(config)#class-map match-all test_dept console(config-classmap)#match srcip 172.16.30.0 255.255.255.0 console(config-classmap)#exit console(config)#class-map match-all development_dept console(config-classmap)#match srcip 172.16.40.0 255.255.255.0 console(config-classmap)#exit 3 Create a DiffServ policy for inbound traffic named internet_access, adding the previously created department classes as instances within this policy. This policy uses the assign-queue attribute to put each department's traffic on a different egress queue. This is how the DiffServ inbound policy connects to the CoS queue settings established below. console(config)#policy-map internet_access in console(config-policy-map)#class finance_dept console(config-policy-classmap)#assign-queue 1 console(config-policy-classmap)#exit console(config-policy-map)#class marketing_dept console(config-policy-classmap)#assign-queue 2 console(config-policy-classmap)#exit console(config-policy-map)#class test_dept console(config-policy-classmap)#assign-queue 3 console(config-policy-classmap)#exit 1308 Configuring Differentiated Services console(config-policy-map)#class development_dept console(config-policy-classmap)#assign-queue 4 console(config-policy-classmap)#exit console(config-policy-map)#exit 4 Attach the defined policy to 10-Gigabit Ethernet interfaces 1/0/1 through 1/0/4 in the inbound direction console(config)#interface tengigabitethernet 1/0/1 console(config-if-Te1/0/1)#service-policy in internet_access console(config-if-Te1/0/1)#exit console(config)#interface tengigabitethernet 1/0/2 console(config-if-Te1/0/2)#service-policy in internet_access console(config-if-Te1/0/2)#exit console(config)#interface tengigabitethernet 1/0/3 console(config-if-Te1/0/3)#service-policy in internet_access console(config-if-Te1/0/3)#exit console(config)#interface tengigabitethernet 1/0/4 console(config-if-Te1/0/4)#service-policy in internet_access console(config-if-Te1/0/4)#exit 5 Set the CoS queue configuration for the (presumed) egress 10-Gigabit Ethernet interface 1/0/1 such that each of queues 1, 2, 3 and 4 get a minimum guaranteed bandwidth of 25%. All queues for this interface use weighted round robin scheduling by default. The DiffServ inbound policy designates that these queues are to be used for the departmental traffic through the assign-queue attribute. It is presumed that the switch will forward this traffic to 10-Gigabit Ethernet interface 1/0/1 based on a normal destination address lookup for internet traffic. console(config)#interface tengigabitethernet 1/0/5 console(config-if-Te1/0/5)#cos-queue min-bandwidth 0 25 25 25 25 0 0 console(config-if-Te1/0/5)#exit console(config)#exit Configuring Differentiated Services 1309 DiffServ for VoIP One of the most valuable uses of DiffServ is to support Voice over IP (VoIP). VoIP traffic is inherently time-sensitive: for a network to provide acceptable service, a guaranteed transmission rate is vital. This example shows one way to provide the necessary quality of service: how to set up a class for UDP traffic, have that traffic marked on the inbound side, and then expedite the traffic on the outbound side. The configuration script is for Router 1 in the accompanying diagram: a similar script should be applied to Router 2. Figure 40-18. DiffServ VoIP Example Network Diagram ` Layer 3 Switch Operating as Router 1 Port 1/0/2 Port 1/0/3 Internet Layer 3 Switch Operating as Router 2 ` 1310 Configuring Differentiated Services The following commands show how to configure the DiffServ example depicted in Figure 40-18. 1 Set queue 6 on all ports to use strict priority mode. This queue shall be used for all VoIP packets. Activate DiffServ for the switch. console#config console(config)#cos-queue strict 6 console(config)#diffserv 2 Create a DiffServ classifier named class_voip and define a single match criterion to detect UDP packets. The class type match-all indicates that all match criteria defined for the class must be satisfied in order for a packet to be considered a match. console(config)#class-map match-all class_voip console(config-classmap)#match protocol udp console(config-classmap)#exit 3 Create a second DiffServ classifier named class_ef and define a single match criterion to detect a DiffServ code point (DSCP) of EF (expedited forwarding). This handles incoming traffic that was previously marked as expedited elsewhere in the network. console(config)#class-map match-all class_ef console(config-classmap)#match ip dscp ef console(config-classmap)#exit 4 Create a DiffServ policy for inbound traffic named pol_voip, then add the previously created classes 'class_ef' and 'class_voip' as instances within this policy. This policy handles incoming packets already marked with a DSCP value of EF (per class_ef definition), or marks UDP packets (per the class_voip definition) with a DSCP value of EF. In each case, the matching packets are assigned internally to use queue 6 of the egress port to which they are forwarded. console(config)#policy-map pol_voip in console(config-policy-map)#class class_ef console(config-policy-classmap)#assign-queue 6 console(config-policy-classmap)#exit console(config-policy-map)#class class_voip console(config-policy-classmap)#mark ip-dscp ef console(config-policy-classmap)#assign-queue 6 Configuring Differentiated Services 1311 console(config-policy-classmap)#exit console(config-policy-map)#exit 5 Attach the defined policy to an inbound service interface. console(config)#interface tengigabitethernet 1/0/1 console(config-if-Te1/0/1)#service-policy in pol_voip console(config-if-Te1/0/1)#exit console(config)#exit 1312 Configuring Differentiated Services Configuring Class-of-Service 41 This chapter describes how to configure the Class-of-Service (CoS) feature. The CoS queueing feature lets you directly configure certain aspects of switch queueing. This provides the desired QoS behavior for different types of network traffic when the complexities of DiffServ are not required. The priority of a packet arriving at an interface can be used to steer the packet to the appropriate outbound CoS queue through a mapping table. CoS queue characteristics that affect queue mapping, such as minimum guaranteed bandwidth, transmission rate shaping, etc., are user-configurable at the queue (or port) level. The topics covered in this chapter include: • CoS Overview • Default CoS Values • Configuring CoS (Web) • Configuring CoS (CLI) • CoS Configuration Example CoS Overview The CoS feature lets you give preferential treatment to certain types of traffic over others. To set up this preferential treatment, you can configure the ingress ports, the egress ports, and individual queues on the egress ports to provide customization that suits your environment. The level of service is determined by the egress port queue to which the traffic is assigned. When traffic is queued for transmission, the rate at which it is serviced depends on how the queue is configured and possibly the amount of traffic present in other queues for that port. Some traffic is classified for service (i.e., packet marking) before it arrives at the switch. If you decide to use these classifications, you can map this traffic to egress queues by setting up a CoS Mapping table. Configuring Class-of-Service 1313 Each ingress port on the switch has a default priority value (set by configuring VLAN Port Priority in the Switching sub-menu) that determines the egress queue its traffic gets forwarded to. Packets that arrive without a VLAN user priority, or packets from ports you’ve identified as “untrusted,” get forwarded according to this default. What Are Trusted and Untrusted Port Modes? Ports can be configured in “trusted” mode or “untrusted” mode with respect to ingress traffic. Ports in Trusted Mode When a port is configured in trusted mode, the system accepts at face value a priority designation encoded within packets arriving on the port. You can configure ports to trust priority designations based on one of the following fields in the packet header: • 802.1 Priority: values 0–7 • IP DSCP: values 0–63 A mapping table associates the designated field values in the incoming packet headers with a traffic class priority (actually a CoS traffic queue). Ports in Untrusted Mode If you configure an ingress port in untrusted mode, the system ignores any priority designations encoded in incoming packets, and instead sends the packets to a traffic queue based on the ingress port’s default priority. How Is Traffic Shaping Used on Egress Traffic? For unit/slot/port interfaces, you can specify a traffic shaping rate for the port (in Kbps) for egress traffic. The traffic shaping rate specifies an upper limit of the transmission bandwidth used. Once the traffic shaping rate has been reached, frames that exceeded the limit remain queued for transmission until the next scheduling slot. 1314 Configuring Class-of-Service How Are Traffic Queues Defined? For each queue, you can specify: • Minimum bandwidth guarantee—A percentage of the port’s maximum negotiated bandwidth reserved for the queue. Unreserved bandwidth can be utilized by lower-priority queues. If the sum of the minimum bandwidth is 100%, then there is no unreserved bandwidth and no sharing of bandwidth is possible. • Scheduler type—strict/weighted: – Strict priority scheduling gives an absolute priority based on CoS queue number, with traffic in the highest numbered queue sent first, then the next lowest numbered queue, and so on. Weighted queues are serviced after all strict priority queues have been serviced. – Weighted scheduling selects packets for transmission with a fixed weighting equal to the CoS queue number plus one. The weighted scheduler measures bandwidth based upon bytes vs. packet counts, offering a better granularity of scheduling. For example, if CoS queues 0, 1, and 2 have an equal offered load toward a congested output port, CoS queue 2 will receive 3/6 of the bandwidth, CoS queue 1 will receive 2/6 of the bandwidth, and CoS queue 0 will receive 1/6 of the bandwidth. The minimum bandwidth setting can be used to override the strict priority and weighted settings. The highest numbered strict priority queue will receive no more bandwidth than 100 percent minus the sum of the minimum bandwidths percentages assigned to the other queues. If used, it is recommended that minimum bandwidth percentages only be high enough to ensure a minimum level of service for any queue; i.e., the sum of the minimum bandwidth percentages is a small fraction of 100%. This ensures that the system can respond to bursts in traffic. Setting the minimum bandwidth percentages such that they sum to 100% effectively sets the scheduler such that sharing of bandwidth is disabled. Which Queue Management Methods Are Supported? The switch supports the following methods, configurable per-interfacequeue, for determining which packets are dropped when the queue is full: • Taildrop—Any packet forwarded to a full queue is dropped regardless of its priority. Configuring Class-of-Service 1315 • Weighted Random Early Detection (WRED)—Drops packets queued for transmission selectively based their drop precedence level. For each of four drop precedence levels on each WRED-enabled interface queue, you can configure the following parameters: – Minimum Threshold: A percentage of the total queue size below which no packets of the selected drop precedence level are dropped. – Maximum Threshold: A percentage of the total queue size above which all packets of the selected drop precedence level are dropped. – Drop Probability: When the queue depth is between the minimum and maximum thresholds, this value provides a scaling factor for increasing the number of packets of the selected drop precedence level that are dropped as the queue depth increases. The drop probability supports configuration in the range of 0 to 10%, and the discrete values 25%, 50%, and 75%. Values not listed are truncated to the next lower value in hardware. CoS Queue Usage CoS queue 7 is reserved by the system and is not assignable. It is generally recommended that the administrator utilize CoS queues 0 to 3, as CoS queues 4-6 may be used by the system for other types of system traffic, for example, routing protocol PDU handling. Default CoS Values Table 41-1 shows the global default values for CoS. Table 41-1. CoS Global Defaults Parameter Default Value Trust Mode 802.1p 802.1p CoS value to queue mapping 802.1p CoS Queue 0, 3 1 1, 2 0 4, 5 2 6, 7 3 1316 Configuring Class-of-Service Table 41-1. CoS Global Defaults Parameter Default Value IP DSCP value to queue mapping IP DSCP Queue 0–7, 24–31 1 8–23 0 32–47 2 48–63 3 Interface Shaping Rate 0 Kbps Minimum Bandwidth 0% Scheduler Type Weighted Queue Management Type Taildrop Drop Precedence Level 1 WRED Decay Exponent 9 WRED Minimum Threshold 40 WRED Maximum Threshold 100 WRED Drop Probability Scale 10 Configuring Class-of-Service 1317 Configuring CoS (Web) This section provides information about the OpenManage Switch Administrator pages for configuring and monitoring CoS features on a Dell Networking N2000, N3000, and N4000 series switches. For details about the fields on a page, click at the top of the page. Mapping Table Configuration Use the Mapping Table Configuration page to define how class of service is assigned to a packet. To display the page, click Quality of Service → Class of Service → Mapping Table Configuration in the navigation panel. CoS(802.1P) is the default mode, so this is the page that displays when Mapping Table Configuration is selected from the Class of Service menu page. Figure 41-1. Mapping Table Configuration — CoS (802.1P) 1318 Configuring Class-of-Service To display the Queue Mapping Table for the selected Trust Mode, click the Show All link at the top of the page. The following figure shows the queue mapping table when CoS (802.1p) is selected as the Trust Mode. Figure 41-2. DSCP Queue Mapping Table Configuring Class-of-Service 1319 Interface Configuration Use the Interface Configuration page to define the interface shaping rate for egress packets on an interface and the decay exponent for WRED queues defined on the interface. Each interface CoS parameter can be configured globally or per-port. A global configuration change is applied to all interfaces in the system. To display the Interface Configuration page, click Quality of Service → Class of Service → Interface Configuration in the navigation panel. Figure 41-3. Interface Configuration 1320 Configuring Class-of-Service Interface Queue Configuration Use the Interface Queue Configuration page to configure egress queues on interfaces. The settings you configure control the amount of bandwidth the queue uses, the scheduling method, and the queue management method. The configuration process is simplified by allowing each CoS queue parameter to be configured globally or per-port. A global configuration change is applied to the same queue ID on all ports in the system. To display the Interface Queue Configuration page, click Quality of Service → Class of Service → Interface Queue Configuration in the navigation panel. Figure 41-4. Interface Queue Configuration Configuring Class-of-Service 1321 To access the Interface Queue Status page, click the Show All link at the top of the page. Interface Queue Drop Precedence Configuration Use the Interface Queue Drop Precedence Configuration page to configure thresholds and scaling values for each of four drop precedence levels on a WRED-enabled interface queue. The settings you configure control the minimum and maximum thresholds and a drop probability scaling factor for the selected drop precedence level. These parameters can be applied to each drop precedence level on a perinterface-queue basis, or can be set globally for the same drop precedence level and queue ID on all interfaces. To display the Interface Queue Drop Precedence Configuration page, click Quality of Service → Class of Service → Interface Queue Drop Precedence Configuration in the navigation panel. 1322 Configuring Class-of-Service Figure 41-5. Interface Queue Drop Precedence Configuration To access the Interface Queue Drop Precedence Status page, click the Show All link at the top of the page. Configuring Class-of-Service 1323 Configuring CoS (CLI) This section provides information about the commands you use to configure CoS settings on the switch. For more information about the commands, see the Dell Networking N2000, N3000, and N4000 Series Switches CLI Reference Guide at support.dell.com/manuals. Mapping Table Configuration Beginning in Privileged Exec mode, use the following commands in to configure the CoS mapping tables. CLI Command Description configure Enter Global Configuration mode. interface interface Enter Interface Configuration mode, where interface is replaced by gigabitethernet unit/slot/port, tengigabitethernet unit/slot/port, or port-channel port-channel number. classofservice dotlp-mapping Map an 802.1p priority to an internal traffic class for a switch. You can also use this command in Global Configuration mode to configure the same mappings on all interfaces. classofservice trust {dot1p | ip-dscp | untrusted} Set the class of service trust mode of an interface. exit Exit to Global Config mode. exit Exit to Privilege Exec mode. show classofservice dotlpmapping Display the current Dot1p (802.1p) priority mapping to internal traffic classes for a specific interface. show classofservice ip-dscpmapping Display the current IP DSCP mapping to internal traffic classes for a specific interface. show classofservice trust Display the current trust mode setting for a specific interface. priority 1324 Configuring Class-of-Service CoS Interface Configuration Commands Beginning in Privileged Exec mode, use the following commands in to configure the traffic shaping and WRED exponent values for an interface. CLI Command Description configure Enter Global Configuration mode. interface interface Enter Interface Configuration mode, where interface is replaced by gigabitethernet unit/slot/port, tengigabitethernet unit/slot/port, or port-channel port-channel number. traffic-shape bw kbps Sets the upper limit on how much traffic can leave a port. The bw variable represents the shaping bandwidth value from 64 to 4294967295 kbps. random-detect exponential- Configure the WRED decay exponent (range: 0–15) weighting-constant exponent for the interface. The weighting constant exponent determines how much of the previous average queue length sample is added to the current average queue length. A value of 0 indicates that no weight is given to the previous sample and only the instantaneous rate is used. A value of 1 indicates that 1/2 of the difference between the instantaneous value and the previous value is added to the current value; a value of 2 implies that 1/4 of the difference is added, 3 implies 1/8 of the difference is added, etc. Interface Queue Configuration Beginning in Privileged Exec mode, use the following commands in to configure and view CoS interface queue settings. CLI Command Description configure Enter Global Configuration mode. interface interface Enter Interface Configuration mode, where interface is replaced by gigabitethernet unit/slot/port, tengigabitethernet unit/slot/port., or port-channel portchannel number. Configuring Class-of-Service 1325 CLI Command Description cos-queue min-bandwidth Specify the minimum transmission bandwidth (range: 0-100% in 1% increments) for each interface queue. cos-queue strict queue-id Activate the strict priority scheduler mode for each specified queue. The queue-id value ranges from 0 to 6. queue-id cos-queue random-detect Set the queue management type for the specified queue to WRED. The no version of this command resets the value to taildrop. exit Exit to Global Config mode. exit Exit to Privilege Exec mode. show interfaces cos-queue Display the class-of-service queue configuration for a specified interface or all interfaces. bw 1326 Configuring Class-of-Service Configuring Interface Queue Drop Probability Beginning in Privileged Exec mode, use the following commands in to configure characteristics of the drop probability and view related settings. The drop probability supports configuration in the range of 0 to 10%, and the discrete values 25%, 50%, and 75%. Values not listed are truncated to the next lower value in hardware. CLI Command Description configure Enter Global Configuration mode. interface interface Enter Interface Configuration mode, where interface is replaced by gigabitethernet unit/slot/port, tengigabitethernet unit/slot/port, or port-channel port-channel number. random-detect queue-parms queue-id [queue-id...] minthresh min1 min2 min3 min4 max-thresh max1 max2 max3 max4 drop-prob prob1 prob2 Configure the maximum and minimum thresholds for one or more queue IDs on a WRED-enabled interface queue. prob3 prob4 You can also use this command in Global Configuration mode to configure the same parameters for one or more queues on all interfaces. exit Exit to Global Config mode. exit Exit to Privilege Exec mode. show interfaces random-detect Display WRED parameters for an interface or all interfaces. Configuring Class-of-Service 1327 CoS Configuration Example Figure 41-6 illustrates the network operation as it relates to CoS mapping and queue configuration. Four packets arrive at the ingress port te1/0/10 in the order A, B, C, and D. port te1/0/10 is configured to trust the 802.1p field of the packet, which serves to direct packets A, B, and D to their respective queues on the egress port. These three packets utilize the 802.1p to CoS Mapping Table for port te1/0/10. In this example, the 802.1p user priority 3 is configured to send the packet to queue 5 instead of the default queue 3. Since packet C does not contain a VLAN tag, the 802.1p user priority does not exist, so port te1/0/10 relies on its default port priority (2) to direct packet C to egress queue 1. Figure 41-6. CoS Mapping and Queue Configuration 1328 Configuring Class-of-Service Continuing this example, the egress port te1/0/8 is configured for strict priority on queue 6, and a weighted scheduling scheme is configured for queues 5-0. Assuming queue 5 has a higher minimum bandwidth than queue 1 (relative bandwidth values are shown as a percentage, with 0% indicating the bandwidth is not guaranteed), the queue service order is 6 followed by 5 followed by 1. Assuming each queue transmits all packets shown in the diagram, the packet transmission order as seen on the network out of port te1/0/8 is B, A, D, C. Thus, packet B, with its strict priority scheduling, is transmitted ahead of the other packets at the egress port. The following commands configure port 10 (ingress interface) and port 8 (egress interface). 1 Configure the Trust mode for port 10. console#config console(config)#interface tengigabitethernet 1/0/10 console(config-if-Te1/0/10)#classofservice trust dot1p 2 For port 10, configure the 802.1p user priority 3 to send the packet to queue 5 instead of the default queue (queue 3). console(config-if-Te1/0/10)#classofservice dot1pmapping 3 5 3 For port 10, specify that untagged VLAN packets should have a default priority of 2. console(config-if-Te1/0/10)#vlan priority 2 console(config-if-Te1/0/10)#exit 4 For port 8, the egress port, configure a weighted scheduling scheme for queues 5-0. console(config)#interface tengigabitethernet 1/0/8 console(config-if-Te1/0/8)#cos-queue minbandwidth 0 0 5 5 10 20 40 5 Configure port 8 to have strict priority on queue 6: console(config-if-Te1/0/8)#cos-queue strict 6 To configure the CoS queues for lossless traffic when transporting iSCSI traffic, set the lossless traffic class to have a one-to-one mapping with the priority value. The following example illustrates how to change the dot1p Configuring Class-of-Service 1329 mapping from the switch defaults to support lossless1 transport of frames on CoS queue 4, with a 50% minimum bandwidth guarantee. Lossless traffic classes generally use the default WRR scheduling mode as opposed to strict priority, to avoid starving other traffic. For example, the following commands assign user priority 4 to CoS queue 4 and reserve 50% of the scheduler bandwidth to CoS queue 4. This implies that, when the switch is congested, the scehduler will service CoS queue 4 fifty percent of the time to the exclusion of all other CoS queues, including higher-priority CoS queues. classofservice dot1p-mapping 4 4 cos-queue min-bandwidth 0 0 0 0 50 0 0 1. Lossless behavior is guaranteed only when configured in conjunction with a congestion control mechanism such as PFC. 1330 Configuring Class-of-Service Configuring Auto VoIP 42 Voice over Internet Protocol (VoIP) allows you to make telephone calls using a computer network over a data network like the Internet. With the increased prominence of delay-sensitive applications (voice, video, and other multimedia applications) deployed in networks today, proper QoS configuration will ensure high-quality application performance. The Auto VoIP feature is intended to provide an easy classification mechanism for voice packets so that they can be prioritized above data packets in order to provide better QoS. Because Auto VoIP is limited to 16 sessions, Voice VLAN is the preferred solution for enterprises wishing to deploy a large scale voice service. The topics covered in this chapter include: • Auto VoIP Overview • Default Auto VoIP Values • Configuring Auto VoIP (Web) • Configuring Auto VoIP (CLI) Auto VoIP Overview The Auto VoIP feature explicitly matches VoIP streams in Ethernet switches and provides them with a better class of service than ordinary traffic. If you enable the Auto VoIP feature on an interface, the interface scans incoming traffic for the following call-control protocols: • Session Initiation Protocol (SIP) • H.323 • Skinny Client Control Protocol (SCCP) When a call-control protocol is detected the switch assigns the traffic in that session to the highest CoS queue, which is generally used for time-sensitive traffic. Configuring Auto VoIP 1331 Auto-VoIP is limited to 16 sessions and makes use of the switch CPU to classify traffic. It is preferable to use the Voice VLAN feature in larger enterprise environments as it uses the switching silicon to classify voice traffic onto a VLAN. How Does Auto-VoIP Use ACLs? Auto-VoIP borrows ACL lists from the global system pool. ACL lists allocated by Auto-VoIP reduce the total number of ACLs available for use by the network operator. Enabling Auto-VoIP uses one ACL list to monitor for VoIP sessions. Each monitored VoIP session utilizes two rules from an additional ACL list. This means that the maximum number of ACL lists allocated by Auto-VoIP is two. Default Auto VoIP Values Table 42-1 shows the global default value for Auto VoIP. Table 42-1. Auto VoIP Global Defaults Parameter Default Value Auto VoIP Disabled 1332 Configuring Auto VoIP Configuring Auto VoIP (Web) This section provides information about the OpenManage Switch Administrator pages for configuring and monitoring Auto VoIP features on a Dell Networking N2000, N3000, and N4000 series switches. For details about the fields on a page, click at the top of the page. Auto VoIP Global Configuration Use the Global Configuration page to enable or disable Auto VoIP on all interfaces. To display the Auto VoIP Global Configuration page, click Quality of Service → Auto VoIP → Global Configuration in the navigation menu. Figure 42-1. Auto VoIP Global Configuration Auto VoIP Interface Configuration Use the Interface Configuration page to enable or disable Auto VoIP on a particular interface. To display the Interface Configuration page, click Quality of Service → Auto VoIP → Interface Configuration in the navigation menu. Configuring Auto VoIP 1333 Figure 42-2. Auto VoIP Interface Configuration To display summary Auto VoIP configuration information for all interfaces, click the Show All link at the top of the page. Figure 42-3. Auto VoIP 1334 Configuring Auto VoIP Configuring Auto VoIP (CLI) This section provides information about the commands you use to configure Auto VoIP settings on the switch. For more information about the commands, see the Dell Networking N2000, N3000, and N4000 Series Switches CLI Reference Guide at support.dell.com/manuals. Mapping Table Configuration Beginning in Privileged Exec mode, use the following commands in to enable Auto VoIP and view its configuration. CLI Command Description configure Enter Global Configuration mode. switchport voice detect auto Enable the VoIP Profile on all the interfaces of the switch. You can also enter Interface Configuration mode and use the same command to enable it on a specific interface. exit Exit to Global Configuration Exec mode. exit Exit to Privilege Exec mode. show switchport voice Show the status of Auto-VoIP on all interfaces or on an interface, if one is specified. Configuring Auto VoIP 1335 1336 Configuring Auto VoIP 43 Managing IPv4 and IPv6 Multicast NOTE: This feature not available on N2000 switches. This chapter describes how to configure and monitor layer 3 multicast features for IPv4 and IPv6, including global IP and IPv6 multicast features as well as multicast protocols, including IGMP, DVMRP, and PIM for IPv4 and MLD and PIM for IPv6. The topics covered in this chapter include: • L3 Multicast Overview • Default L3 Multicast Values • Configuring General IPv4 Multicast Features (Web) • Configuring IPv6 Multicast Features (Web) • Configuring IGMP and IGMP Proxy (Web) • Configuring MLD and MLD Proxy (Web) • Configuring PIM for IPv4 and IPv6 (Web) • Configuring DVMRP (Web) • Configuring L3 Multicast Features (CLI) • L3 Multicast Configuration Examples L3 Multicast Overview IP Multicasting enables a network host (or multiple hosts) to send an IP datagram to multiple destinations simultaneously. The initiating host sends each multicast datagram only once to a destination multicast group address, and multicast routers forward the datagram only to hosts who are members of the multicast group. Multicast enables efficient use of network bandwidth because each multicast datagram needs to be transmitted only once on each network link, regardless of the number of destination hosts. Multicasting contrasts with IP unicasting, which sends a separate datagram to each Managing IPv4 and IPv6 Multicast 1337 recipient host. The IP routing protocols can route multicast traffic, but the IP multicast protocols handle the multicast traffic more efficiently with better use of network bandwidth. Applications that often send multicast traffic include video or audio conferencing, Whiteboard tools, stock distribution tickers, and IP-based television (IP/TV). What Is IP Multicast Traffic? IP multicast traffic is traffic that is destined to a host group. Host groups are identified by class D IP addresses, which range from 224.0.0.0 to 239.255.255.255. When a packet with a broadcast or multicast destination IP address is received, the switch will forward a copy into each of the remaining network segments in accordance with the IEEE MAC Bridge standard. Eventually, the packet is made accessible to all nodes connected to the network. This approach works well for broadcast packets that are intended to be seen or processed by all connected nodes. In the case of multicast packets, however, this approach could lead to less efficient use of network bandwidth, particularly when the packet is intended for only a small number of nodes. Packets will be flooded into network segments where no node has any interest in receiving the packet. The L3 multicast features on the switch help to ensure that only the hosts in the multicast group receive the multicast traffic for that group. Multicast applications send one copy of a packet, and address it to a group of receivers (Multicast Group Address) rather than to a single receiver (unicast address). Multicast depends on the network to forward the packets to only those networks and hosts that need to receive them. 1338 Managing IPv4 and IPv6 Multicast What Multicast Protocols Does the Switch Support? Multicast protocols are used to deliver multicast packets from one source to multiple receivers. Table 43-1 summarizes the multicast protocols that the switch supports. Table 43-1. Multicast Protocol Support Summary Protocol IPv4 or IPv6 For Communication Between IGMP IPv4 Host-to-L3 switch/router IGMP Proxy IPv4 Host-to-L3 switch/router MLD IPv6 Host-to-L3 switch/router MLD Proxy IPv6 Host-to-L3 switch/router PIM-SM IPv4 and IPv6 L3-switch/router-to-L3 switch/router PIM-DM IPv4 and IPv6 L3-switch/router-to-L3 switch/router DVMRP IPv4 L3-switch/router-to-L3 switch/router What Are the Multicast Protocol Roles? Hosts must have a way to identify their interest in joining any particular multicast group, and routers must have a way to collect and maintain group memberships. These functions are handled by the IGMP protocol in IPv4. In IPv6, multicast routers use the Multicast Listener Discover (MLD) protocol to maintain group membership information. Multicast routers must also be able to construct a multicast distribution tree that enables forwarding multicast datagrams only on the links that are required to reach a destination group member. Protocols such as DVMRP, and PIM handle this function. IGMP and MLD are multicast group discovery protocols that are used between the clients and the local multicast router. PIM-SM, PIM-DM, and DVMRP are multicast routing protocols that are used across different subnets, usually between the local multicast router and remote multicast router. Managing IPv4 and IPv6 Multicast 1339 When Is L3 Multicast Required on the Switch? Use the IPv4/IPv6 multicast feature on Dell Networking series switches to route multicast traffic between VLANs on the switch. If all hosts connected to the switch are on the same subnet, there is no need to configure the IP/IPv6 multicast feature. If the switch does not require L3 routing, you can use IGMP snooping or MLD snooping to manage port-based multicast group membership. For more information, see "What Is IGMP Snooping?" on page 805 and "What Is MLD Snooping?" on page 807. If the local network does not have a multicast router, you can configure the switch to act as the IGMP querier. For more information, see "IGMP Snooping Querier" on page 807. If the switch is configured as a L3 switch and handles inter-VLAN routing through static routes, OSPF, or RIP, and multicast traffic is transmitted within the network, enabling and configuring L3 multicast routing on the switch is recommended. Multicast packets locally routed into a VLAN by the router are flooded to all ports in the VLAN. Multicast packets ingressing a port that is a member of a routed VLAN are flooded to all ports in the VLAN other than the receiving port. It is strongly recommended that multicast routed VLANs only contain two ports, one on each connecting switch. A VLAN carrying multicast traffic should never traverse a multicast router, as ingress multicast traffic is L2switched across the VLAN, defeating the purpose of the multicast router. Determining Which Multicast Protocols to Enable IGMP is required on any multicast router that serves IPv4 hosts. IGMP is not required on inter-router links. MLD is required on any router that serves IPv6 hosts. MLD is not required on inter-router links. PIM-DM, PIM-SM, and DVMRP are multicast routing protocols that help determine the best route for IP (PIM and DVMRP) and IPv6 (PIM) multicast traffic. IGMP is automatically enabled whenever an IPv4 multicast routing protocol is enabled that requires it, i.e., PIM-SM, PIM-DM, and DVMRP via the CLI. Likewise, MLD is automatically enabled whenever an IPv6 multicast routing protocol is enabled that requires it (PIM-SM and PIM-DM) via the CLI. IGMP and MLD may not be separately enabled or disabled via the CLI. They may be separately enabled/disabled via the web. 1340 Managing IPv4 and IPv6 Multicast For more information about when to use PIM-DM, see "Using PIM-DM as the Multicast Routing Protocol" on page 1352. For more information about when to use PIM-SM, see "Using PIM-SM as the Multicast Routing Protocol" on page 1343. For more information about when to configure DVMRP, see "Using DVMRP as the Multicast Routing Protocol" on page 1354. Unless specifically required, IGMP/MLD snooping should be disabled on L3 multicast routers. What Is the Multicast Routing Table? Multicast capable/enabled routers forward multicast packets based on the routes in the Multicast Routing Information Base (MRIB). These routes are created in the MRIB during the process of building multicast distribution trees by the Multicast Protocols running on the router. Different IP Multicast routing protocols use different techniques to construct these multicast distribution trees. What Is IGMP? The Internet Group Management Protocol (IGMP) is used by IPv4 systems (hosts, L3 switches, and routers) to report their IP multicast group memberships to any neighboring multicast routers. The Dell Networking N2000, N3000, and N4000 series switches performs the multicast router role of the IGMP protocol, which means it collects the membership information needed by the active multicast routing protocol. IGMP is automatically enabled when PIM or DVMRP are enabled via the CLI. The Dell Networking N2000, N3000, and N4000 series switches also supports IGMP Version 3. Version 3 adds support for source filtering, which is the ability for a system to report interest in receiving packets only from specific source addresses, as required to support Source-Specific Multicast [SSM], or from all but specific source addresses, sent to a particular multicast address. Version 3 is designed to be interoperable with Versions 1 and 2. Understanding IGMP Proxy IGMP proxy enables a multicast router to learn multicast group membership information and forward multicast packets based upon the group membership information. The IGMP Proxy is capable of functioning only in certain topologies that do not require Multicast Routing Protocols (i.e., Managing IPv4 and IPv6 Multicast 1341 DVMRP, PIM-DM, and PIM-SM) and have a tree-like topology, as there is no support for features like reverse path forwarding (RPF) to correct packet route loops. The proxy contains many downstream interfaces and a unique upstream interface explicitly configured. It performs the host side of the IGMP protocol on its upstream interface and the router side of the IGMP protocol on its downstream interfaces. The IGMP proxy offers a mechanism for multicast forwarding based only on IGMP membership information. The router must decide about forwarding packets on each of its interfaces based on the IGMP membership information. The proxy creates the forwarding entries based on the membership information and adds it to the multicast forwarding cache (MFC) in order not to make the forwarding decision for subsequent multicast packets with same combination of source and group. What Is MLD? Multicast Listener Discovery (MLD) protocol enables IPv6 routers to discover the presence of multicast listeners, the hosts that wish to receive the multicast data packets, on its directly-attached interfaces. The protocol specifically discovers which multicast addresses are of interest to its neighboring nodes and provides this information to the active multicast routing protocol that makes decisions on the flow of multicast data packets. MLD is automatically enabled whenever IPv6 PIM is enabled on IPv6 interfaces via the CLI. The Multicast router sends General Queries periodically to request multicast address listeners information from systems on an attached network. These queries are used to build and refresh the multicast address listener state on attached networks. Multicast listeners respond to these queries by reporting their multicast addresses listener state and their desired set of sources with Current-State Multicast address Records in the MLD2 Membership Reports. The Multicast router also processes unsolicited Filter-Mode-Change records and Source-List-Change Records from systems that want to indicate interest in receiving or not receiving traffic from particular sources. The Dell Networking implementation of MLD v2 supports the multicast router portion of the protocol (i.e., not the listener portion). It is backwardcompatible with MLD v1. 1342 Managing IPv4 and IPv6 Multicast What Is PIM? The Protocol Independent Multicast protocol is a simple, protocolindependent multicast routing protocol. PIM uses an existing unicast routing table and a Join/Prune/Graft mechanism to build a tree. Dell Networking series switches support two types of PIM: sparse mode (PIM-SM) and dense mode (PIM-DM). PIM-SM is most effective in networks with a sparse population of multicast receivers. In contrast, PIM-DM is most effective in networks with densely populated multicast receivers. In other words, PIM-DM can be used if the majority of network hosts request to receive a multicast stream, while PIMSM might be a better choice in networks in which a small percentage of network hosts, located throughout the network, wish to receive the multicast stream. Using PIM-SM as the Multicast Routing Protocol PIM-SM is used to efficiently route multicast traffic to multicast groups that may span wide area networks and where bandwidth is constrained. PIM-SM uses shared trees by default and implements source-based trees for efficiency. PIM-SM assumes that no hosts want the multicast traffic unless they specifically ask for it. It initially creates a shared distribution tree centered on a defined “rendezvous point” (RP) through which source traffic is relayed to the ultimate receiver. Multicast traffic sources first send the multicast data to the RP, which in turn sends the data down the shared tree to the receivers. Shared trees centered on an RP do not necessarily provide the shortest or most optimal path. In such cases, a Dell Networking PIM-SM router adjacent to the host switches to the shortest path upon seeing the very first multicast data packet. Many IP multicast applications, such as those that handle real-time dissemination of financial information, require high performance. Multicast group membership management (IGMP), unicast routing protocols (OSPF, RIP), and multicast routing protocols are all required to enable end-to-end multicast capabilities. The RP is a critical function for PIM-SM deployments. RP redundancy is always recommended. In a shared-tree model, multicast traffic from the multicast source is routed via the RP. If the RP goes down, the multicast receivers do not receive traffic until the RP comes up again. In general, more than one RP is configured (for a group range) to provide RP redundancy. The PIM-SM router acting as a BSR advertises the list of Managing IPv4 and IPv6 Multicast 1343 candidate RPs to all the PIM routers in the network. Each PIM router then runs the RP selection algorithm to determine an RP for the given group range. All the interested PIMSM routers then initiate re-reception of traffic through this new RP, and the multicast traffic is rerouted via the new RP. This is to provide high availability to the multicast applications and help ensure that the multicast traffic is recovered quickly in such scenarios. PIM-SM Protocol Operation This section describes the workings of PIM-SM protocol per RFC 4601. The protocol operates essentially in three phases, as explained in the following sections. Phase-1: RP Tree Figure 43-1. PIM-SM Shared Tree Join • In this example, an active receiver (attached to leaf router at the bottom of the drawing) has joined multicast group “G”. • The leaf router (labeled DR above) knows the IP address of the Rendezvous Point (RP) for group G and sends a (*, G) Join for this group towards the RP. 1344 Managing IPv4 and IPv6 Multicast • This (*, G) Join travels hop-by-hop to the RP, building a branch of the Shared Tree that extends from the RP to the last-hop router directly connected to the receiver. • At this point, group “G” traffic can flow down the Shared Tree to the receiver. Phase-2: Register Stop Figure 43-2. PIM-SM Sender Registration—Part1 • As soon as an active source for group G sends a packet, the designated router (DR) that is attached to this source is responsible for “Registering” this source with the RP and requesting the RP to build a tree back to that router. • To do this, the source router encapsulates the multicast data from the source in a special PIM-SM message, called the Register message, and unicasts that data to the RP. • When the RP receives the Register message, it does two things: – It de-encapsulates the multicast data packet inside of the Register message and forwards it down the Shared Tree. Managing IPv4 and IPv6 Multicast 1345 – The RP sends a source group (S, G) Join back towards the source to create a branch of an (S, G) Shortest-Path Tree (SPT). This results in the (S, G) state being created in the entire router path along the SPT, including the RP. Figure 43-3. PIM-SM Sender Registration—Part 2 • As soon as the SPT is built from the Source router to the RP, multicast traffic begins to flow unencapsulated from source S to the RP. • Once this is complete, the RP Router will send a “Register Stop” message to the first-hop router to tell it to stop sending the encapsulated data to the RP. 1346 Managing IPv4 and IPv6 Multicast Phase 3: Shortest Path Tree Figure 43-4. PIM-SM SPT—Part 1 • PIM-SM has the capability for last-hop routers (i.e., routers with directly connected group members) to switch to the Shortest-Path Tree and bypass the RP. This switchover is based upon an implementation-specific function called SwitchToSptDesired(S,G) in the standard and generally takes a number of seconds to switch to the SPT. • In the above example, the last-hop router (at the bottom of the drawing) sends an (S, G) Join message toward the source to join the SPT and bypass the RP. • This (S, G) Join messages travels hop-by-hop to the first-hop router (i.e., the router connected directly to the source), thereby creating another branch of the SPT. This also creates (S, G) state in all the routers along this branch of the SPT. Managing IPv4 and IPv6 Multicast 1347 Figure 43-5. PIM-SM SPT—Part 2 • Finally, special (S, G) RP-bit Prune messages are sent up the Shared Tree to prune off this (S, G) traffic from the Shared Tree. If this were not done, (S, G) traffic would continue flowing down the Shared Tree resulting in duplicate (S, G) packets arriving at the receiver. 1348 Managing IPv4 and IPv6 Multicast Figure 43-6. PIM-SM SPT—Part 3 • At this point, (S, G) traffic is now flowing directly from the first -hop router to the last-hop router and from there to the receiver. Figure 43-7. PIM-SM SPT—Part 4 Managing IPv4 and IPv6 Multicast 1349 • At this point, the RP no longer needs the flow of (S, G) traffic since all branches of the Shared Tree (in this case there is only one) have pruned off the flow of (S, G) traffic. • As a result, the RP will send (S, G) Prunes back toward the source to shut off the flow of the now unnecessary (S, G) traffic to the RP. NOTE: This will occur if the RP has received an (S, G) RP-bit Prune on all interfaces on the Shared Tree. Figure 43-8. PIM-SM SPT—Part 5 • As a result of the SPT-Switchover, (S, G) traffic is now flowing only from the first-hop router to the last-hop router and from there to the receiver. Notice that traffic is no longer flowing to the RP. The PIM standard requires support for multi-hop RP in that a router running PIM can act as an RP even if it is multiple router hops away from the multicast source. This requires that the first-hop router perform encapsulation of the multicast data and forward it as unicast toward the RP. In practice, this encapsulation is almost always performed in software due to the complexity of the operation. Likewise, the RP must perform deencapsulation and forwarding of the multicast packets in software. This 1350 Managing IPv4 and IPv6 Multicast creates a performance problem in that it limits the number of packets that can be processed and places a high load on the CPUs in the first hop and RP routers, which can then adversely affect other router functions. Dell Networking Optimizations to PIM-SM Dell Networking switches perform the following optimizations to reduce the impact of multicast encapsulation/de-encapsulation and provide a higher level of multicast performance in the network. • Limiting the number of packets sent to the RP by the first-hop router. When a multicast data source (S) starts sending data destined for a multicast group (G), the first-hop router receives these packets and traps them to its local CPU. A Dell Networking first-hop router immediately blocks further data packets in the stream and prevents them from reaching the CPU. The first-hop router then unicast-encapsulates the first received data packet in the form of a PIM Register message and software forwards it to the RP. When a Dell Networking first-hop router subsequently receives the PIM Join from the RP, the block is replaced with a regular multicast forwarding entry so that subsequent data packets are forwarded in the hardware. If the initial Register message(s) does not reach the RP, or the PIM Join sent in response does not reach the first-hop router, then the data stream would never get forwarded. To solve this, the negative entry is timed out and removed after 3 seconds so that the process can be repeated until it succeeds. • In Phase 3—Shortest Path Tree, the last-hop router initiates a switchover to the SPT tree by sending a PIM (S,G) Join message towards the source as soon as it receives the first data packet via the (*,G) shared tree. Per the standard, this function is used to detect suboptimal routing of multicast traffic. Dell Networking multicast eliminates the SwitchToSptDesired(S,G) function and performs as if the SwitchToSptDesired(S,G) function always returns “true” as soon as it receives the first multicast packet instead of waiting for 30 seconds. • Dell Networking RPs do not wait to receive the native multicast data but immediately respond to the PIM (S,G) Join by sending a 'Register Stop' message to the source's first-hop router to inform it that it can stop Managing IPv4 and IPv6 Multicast 1351 sending the encapsulated Register messages. This removes the load from the CPU of the first-hop router and the RP, as they no longer need to encapsulate and de-encapsulate register messages with multicast data. These optimizations significantly reduce the load on first-hop routers and RPs to encapsulate/de-encapsulate PIM register messages and their associated multicast data. In addition, the switchover to the SPT is initiated immediately upon the first multicast packet reaching the last-hop router. This leads to significantly faster response times for receiving the full multicast stream directly from the first-hop router (as opposed to the typical bandwidth-limited stream traversing the RP). Using PIM-DM as the Multicast Routing Protocol Unlike PIM-SM, PIM-DM creates source-based shortest-path distribution trees that make use of reverse-path forwarding (RPF). PIM-DM assumes that when a sender starts sending data, all downstream routers and hosts want to receive a multicast datagram. PIM-DM initially floods multicast traffic throughout the network. Routers that do not have any downstream neighbors prune back the unwanted traffic. In addition to PRUNE messages, PIM-DM makes use of graft and assert messages. Graft messages are used whenever a new host wants to join the group. Assert messages are used to shutoff duplicate flows on the same multi-access network. There are two versions of PIM-DM. Version 2 does not use the IGMP message; instead, it uses a message that is encapsulated in an IP package, with protocol number 103. In Version 2, a Hello message is introduced in place of a query message. PIM-DM is appropriate for: • Densely distributed receivers • Few senders-to-many receivers (due to frequent flooding) • High volume of multicast traffic • Constant stream of traffic To minimize the repeated flooding of datagrams and subsequent pruning associated with a particular source-group (S,G) pair, PIM-DM uses a State Refresh message. This message is sent by the router(s) directly connected to the source and is propagated throughout the network. When received by a 1352 Managing IPv4 and IPv6 Multicast router on its RPF interface, the State Refresh message causes an existing prune state to be refreshed. State Refresh messages are generated periodically by the router directly attached to the source. What Is DVMRP? DVMRP is an interior gateway protocol that is suitable for routing multicast traffic within an autonomous system (AS). DVMRP should not be used between different autonomous systems due to limitations with hop count and scalability. NOTE: In addition to DVMRP, the switch supports the Protocol-Independent Multicast (PIM) sparse-mode (PIM-SM) and dense-mode (PIM-SM) routing protocol. Only one multicast routing protocol can be operational on the switch at any time. If you enable DVMRP, PIM must be disabled. Similarly, if PIM is enabled, DVMRP must be disabled. DVMRP exchanges probe packets with all its DVMRP-enabled routers, it establishes two-way neighboring relationships, and it builds a neighbor table. DVMRP exchanges report packets and creates a unicast topology table, with which it builds the multicast routing table. This table is used to route the multicast packets. Since every DVMRP router uses the same unicast routing protocol, routing loops are avoided. Understanding DVMRP Multicast Packet Routing DVMRP is based on RIP; it forwards multicast datagrams to other routers in the AS and constructs a forwarding table based on information it learns in response. More specifically, it uses this sequence. • A new multicast packet is forwarded to the entire multicast network, with respect to the time-to-live (TTL) of the packet. • The TTL restricts the area to be flooded by the message. • All routers that do not have members on directly-attached subnetworks send back Prune messages to the upstream router. • The branches that transmit a prune message are deleted from the delivery tree. • The delivery tree which is spanning to all the members in the multicast group, is constructed in the form of a DVMRP forwarding table. Managing IPv4 and IPv6 Multicast 1353 Using DVMRP as the Multicast Routing Protocol DVMRP is used to communicate multicast information between L3 switches or routers. If a Dell Networking N2000, N3000, and N4000 series switches handles inter-VLAN routing for IP traffic, including IP multicast traffic, multicast routing might be required on the switch. DVMRP is best suited for small networks where the majority of hosts request a given multicast traffic stream. DVMRP is similar to PIM-DM in that it floods multicast packets throughout the network and prunes branches where the multicast traffic is not desired. DVMRP was developed before PIM-DM, and it has several limitations that do not exist with PIM-DM. You might use DVMRP as the multicast routing protocol if it has already been widely deployed within the network. Microsoft Network Load Balancing Dell Networking switches support Microsoft Network Load Balancing (NLB) in unicast mode only. When using Microsoft NLB, ensure that the Cluster Operation Mode is configured to the default value of Unicast. 1354 Managing IPv4 and IPv6 Multicast Default L3 Multicast Values IP and IPv6 multicast is disabled by default. Table 43-2 shows the default values for L3 multicast and the multicast protocols. Table 43-2. L3 Multicast Defaults Parameter Default Value IPv4 Multicast Defaults L3 Multicast Admin Mode Disabled Maximum Multicast Routing Table Entries 2048 (1536 IPv4/512 IPv6) Switch sizes are as follows: N2000/N3000—1536 IPv4 / 512 IPv6 N4000 —512 IPv4 / 256 IPv6 Static Multicast Routes None configured Interface TTL Threshold 1 IGMP Defaults IGMP Admin Mode Disabled globally and on all interfaces IGMP Version v3 IGMP Robustness 2 IGMP Query Interval 125 seconds IGMP Query Max Response Time 100 seconds IGMP Startup Query Interval 31 seconds IGMP Startup Query Count 2 IGMP Last Member Query Interval 1 second IGMP Last Member Query Count 2 IGMP Proxy Interface Mode Disabled IGMP Proxy Unsolicited Report Interval 1 second MLD Defaults MLD Admin Mode Disabled globally and on all interfaces MLD Version v2 Managing IPv4 and IPv6 Multicast 1355 Table 43-2. L3 Multicast Defaults (Continued) Parameter Default Value MLD Query Interval 125 seconds MLD Query Max Response Time 10,000 milliseconds MLD Last Member Query Interval 1000 milliseconds MLD Last Member Query Count 2 MLD Proxy Interface Mode Disabled MLD Proxy Unsolicited Report Interval 1 second PIM Defaults PIM Protocol Disabled globally and on all interfaces PIM Hello Interval 30 seconds (when enabled on an interface) PIM-SM Join/Prune Interval 60 seconds (when enabled on an interface) PIM-SM BSR Border Disabled PIM-SM DR Priority 1 (when enabled on an interface) PIM Candidate Rendezvous Points (RPs) None configured PIM Static RP None configured PIM Source-Specific Multicast (SSM) Range None configured. Default SSM group address is 232.0.0.0/8 for IPv4 multicast and ff3x::/32 for IPv6 multicast. PIM BSR Candidate Hash Mask Length 30 (IPv4) 126 (IPv6) PIM BSR Candidate Priority 0 DVMRP Defaults DVMRP Admin Mode Disabled globally and on all interfaces DVMRP Version 3 DVMRP Interface Metric 1 1356 Managing IPv4 and IPv6 Multicast Configuring General IPv4 Multicast Features (Web) This section provides information about the OpenManage Switch Administrator pages for configuring and monitoring the L3 multicast features that are not protocol-specific on a Dell Networking N2000, N3000, and N4000 series switches. For details about the fields on a page, click at the top of the page. Multicast Global Configuration Use the Global Configuration page to configure the administrative status of Multicast Forwarding in the router, and to display global multicast parameters. To display the page, click IPv4 Multicast → Multicast → Global Configuration in the navigation panel. Figure 43-9. Multicast Global Configuration Managing IPv4 and IPv6 Multicast 1357 Multicast Interface Configuration Use the Interface Configuration page to configure the TTL threshold of a multicast interface. At least one VLAN routing interface must be configured on the switch before fields display on this page. To display the page, click IPv4 Multicast → Multicast → Interface Configuration in the navigation panel. Figure 43-10. 1358 Multicast Interface Configuration Managing IPv4 and IPv6 Multicast Multicast Route Table Use the Route Table page to view information about the multicast routes in the IPv4 multicast routing table. To display the page, click IPv4 Multicast → Multicast → Multicast Route Table Multicast Route Table Figure 43-11. Multicast Route Table Managing IPv4 and IPv6 Multicast 1359 Multicast Admin Boundary Configuration The definition of an administratively scoped boundary is a way to stop the ingress and egress of multicast traffic for a given range of multicast addresses on a given routing interface. Use the Admin Boundary Configuration page to configure a new or existing administratively scoped boundary. To see this page, you must have configured a valid routing interface and multicast. To display the page, click IPv4 Multicast → Multicast → Admin Boundary Configuration in the navigation panel. Figure 43-12. 1360 Multicast Admin Boundary Configuration Managing IPv4 and IPv6 Multicast Multicast Admin Boundary Summary Use the Admin Boundary Summary page to display existing administratively scoped boundaries. To display the page, click IPv4 Multicast → Multicast → Admin Boundary Summary in the navigation panel. Figure 43-13. Multicast Admin Boundary Summary Multicast Static MRoute Configuration Use the Static MRoute Configuration page to configure a new static entry in the Mroute table or to modify an existing entry. To display the page, click IPv4 Multicast → Multicast → Static MRoute Configuration in the navigation panel. Figure 43-14. Multicast Static MRoute Configuration Managing IPv4 and IPv6 Multicast 1361 Multicast Static MRoute Summary Use the Static MRoute Summary page to display static routes and their configurations. To display the page, click IPv4 Multicast → Multicast → Static MRoute Summary in the navigation panel. Figure 43-15. 1362 Multicast Static MRoute Summary Managing IPv4 and IPv6 Multicast Configuring IPv6 Multicast Features (Web) This section provides information about the OpenManage Switch Administrator pages for configuring and monitoring the IPv6 multicast features that are not protocol-specific on a Dell Networking N2000, N3000, and N4000 series switches. For details about the fields on a page, click at the top of the page. IPv6 Multicast Route Table Use the Multicast Route Table page to view information about the multicast routes in the IPv6 multicast routing table. To display the page, click IPv6 Multicast → Multicast → Multicast Route Table. Figure 43-16. IPv6 Multicast Route Table Managing IPv4 and IPv6 Multicast 1363 Configuring IGMP and IGMP Proxy (Web) This section provides information about the OpenManage Switch Administrator pages for configuring and monitoring the IGMP and IGMP proxy features on a Dell Networking N2000, N3000, and N4000 series switches. For details about the fields on a page, click at the top of the page. IGMP Global Configuration Use the Global Configuration page to set IGMP on the system to active or inactive. To display the page, click IPv4 Multicast → IGMP → Global Configuration in the navigation panel. Figure 43-17. 1364 IGMP Global Configuration Managing IPv4 and IPv6 Multicast IGMP Interface Configuration Use the Interface Configuration page to configure and/or display router interface parameters. You must configure at least one valid routing interface before you can access this page and configure IP Multicast IGMP. To display the page, click IPv4 Multicast → IGMP → Routing Interface → Interface Configuration in the navigation panel. Figure 43-18. IGMP Interface Configuration Managing IPv4 and IPv6 Multicast 1365 IGMP Interface Summary Use the Interface Summary page to display IGMP routing parameters and data. You must configure at least one IGMP router interface to access this page. To display the page, click IPv4 Multicast → IGMP → Routing Interface → Interface Summary in the navigation panel. Figure 43-19. IGMP Interface Summary IGMP Cache Information Use the Cache Information page to display cache parameters and data for an IP multicast group address. Group membership reports must have been received on the selected interface for data to display on the page. To display the page, click IPv4 Multicast → IGMP → Routing Interface → Cache Information in the navigation panel. 1366 Managing IPv4 and IPv6 Multicast Figure 43-20. IGMP Cache Information Managing IPv4 and IPv6 Multicast 1367 IGMP Interface Source List Information Use the Source List Information page to display detailed membership information for an interface. Group membership reports must have been received on the selected interface for data to display information. To display the page, click IPv4 Multicast → IGMP → Routing Interface → Source List Information in the navigation panel. Figure 43-21. 1368 IGMP Interface Source List Information Managing IPv4 and IPv6 Multicast IGMP Proxy Interface Configuration The IGMP Proxy is used by IGMP Router (IPv4 system) to enable the system to issue IGMP host messages on behalf of hosts that the system discovered through standard IGMP router interfaces. Thus, this feature acts as proxy to all hosts residing on its router interfaces. Use the Interface Configuration page to configure IGMP proxy for a VLAN interface. You must have configured at least one VLAN routing interface before configuring or displaying data for an IGMP proxy interface, and it should not be an IGMP routing interface. To display the page, click IPv4 Multicast → IGMP → Proxy Interface → Interface Configuration in the navigation panel. Figure 43-22. IGMP Proxy Interface Configuration Managing IPv4 and IPv6 Multicast 1369 IGMP Proxy Configuration Summary Use the Configuration Summary page to display proxy interface configurations by interface. You must have configured at least one VLAN routing interface configured before data displays on this page. To display the page, click IPv4 Multicast → IGMP → Proxy Interface → Configuration Summary in the navigation panel. Figure 43-23. 1370 IGMP Proxy Configuration Summary Managing IPv4 and IPv6 Multicast IGMP Proxy Interface Membership Info Use the Interface Membership Info page to display interface membership data for a specific IP multicast group address. You must have configured at least one VLAN routing interface before you can display interface membership information, and it should not be an IGMP routing interface. Also, if no group membership reports have been received on the selected interface, no data displays on this page. To display the page, click IPv4 Multicast → IGMP → Proxy Interface → Interface Membership Info in the navigation panel. Figure 43-24. IGMP Proxy Interface Membership Info Managing IPv4 and IPv6 Multicast 1371 Detailed IGMP Proxy Interface Membership Information Use the Interface Membership Info Detailed page to display detailed interface membership data. You must have configured at least one VLAN routing interface before you can display detailed interface membership information, and it should not be an IGMP routing interface. Also, if no group membership reports have been received on the selected interface you cannot display data. To display the page, click IPv4 Multicast → IGMP → Proxy Interface → Interface Membership Info Detailed in the navigation panel. Figure 43-25. 1372 IGMP Proxy Interface Membership Info Detailed Managing IPv4 and IPv6 Multicast Configuring MLD and MLD Proxy (Web) This section provides information about the OpenManage Switch Administrator pages for configuring and monitoring the MLD and MLD proxy features on a Dell Networking N2000, N3000, and N4000 series switches. For details about the fields on a page, click at the top of the page. MLD Global Configuration Use the Global Configuration page to administratively enable and disable the MLD service. To display the page, click IPv6 Multicast → MLD → Global Configuration in the navigation panel. Figure 43-26. MLD Global Configuration Managing IPv4 and IPv6 Multicast 1373 MLD Routing Interface Configuration Use the Interface Configuration page to enable selected IPv6 router interfaces to discover the presence of multicast listeners, the nodes who wish to receive the multicast data packets, on its directly attached interfaces. To access this page, click IPv6 Multicast → MLD → Routing Interface → Interface Configuration in the navigation panel. Figure 43-27. 1374 MLD Routing Interface Configuration Managing IPv4 and IPv6 Multicast MLD Routing Interface Summary Use the Interface Summary page to display information and statistics on a selected MLD-enabled interface. You must configure at least one IGMP VLAN routing interface to access this page. To access this page, click IPv6 Multicast → MLD → Routing Interface → Interface Summary in the navigation panel. Figure 43-28. MLD Routing Interface Summary MLD Routing Interface Cache Information The Interface Cache Information page displays cache parameters and data for an IP multicast group address that has been reported to operational MLD routing interfaces. You must configure at least one MLD VLAN routing interface to access this page. Also, group membership reports must have been Managing IPv4 and IPv6 Multicast 1375 received on the selected interface in order for data to be displayed here. To access this page, click IPv6 Multicast → MLD → Routing Interface → Cache Information in the navigation panel. Figure 43-29. MLD Routing Interface Cache Information MLD Routing Interface Source List Information The Interface Source List Information page displays detailed membership information for an interface. You must configure at least one MLD VLAN routing interface to access this page. Also, group membership reports must have been received on the selected interface in order for data to be displayed here. To access this page, click IPv6 Multicast → MLD → Routing Interface → Source List Information in the navigation panel. Figure 43-30. 1376 MLD Routing Interface Source List Information Managing IPv4 and IPv6 Multicast MLD Traffic The MLD Traffic page displays summary statistics on the MLD messages sent to and from the router. To access this page, click IPv6 Multicast → MLD → Routing Interface → MLD Traffic in the navigation panel. Figure 43-31. MLD Traffic Managing IPv4 and IPv6 Multicast 1377 MLD Proxy Configuration When you configure an interface in MLD proxy mode, it acts as a proxy multicast host that sends MLD membership reports on one VLAN interface for MLD Membership reports received on all other MLD-enabled VLAN routing interfaces. Use the Interface Configuration page to enable and disable ports as MLD proxy interfaces. To display this page, click IPv6 Multicast → MLD → Proxy Interface → Interface Configuration in the navigation panel. Figure 43-32. 1378 MLD Proxy Interface Configuration Managing IPv4 and IPv6 Multicast MLD Proxy Configuration Summary Use the Configuration Summary page to view configuration and statistics on MLD proxy-enabled interfaces. To display this page, click IPv6 Multicast → MLD → Proxy Interface → Configuration Summary in the navigation panel. Figure 43-33. MLD Proxy Configuration Summary Managing IPv4 and IPv6 Multicast 1379 MLD Proxy Interface Membership Information The Interface Membership Information page lists each IP multicast group for which the MLD proxy interface has received membership reports. To display this page, click IPv6 Multicast → MLD → Proxy interface → Interface Membership Info in the navigation panel. Figure 43-34. 1380 Interface Membership Information Managing IPv4 and IPv6 Multicast Detailed MLD Proxy Interface Membership Information The Interface Membership Information Detailed page provides additional information about the IP multicast groups for which the MLD proxy interface has received membership reports. To display this page, click IPv6 Multicast → MLD → Proxy Interface → Interface Membership Info Detailed in the navigation panel. Figure 43-35. Interface Membership Information—Detailed Managing IPv4 and IPv6 Multicast 1381 Configuring PIM for IPv4 and IPv6 (Web) This section provides information about the OpenManage Switch Administrator pages for configuring and monitoring PIM-SM and PIM-DM for IPv4 and IPv6 multicast routing on a Dell Networking N2000, N3000, and N4000 series switches. For details about the fields on a page, click at the top of the page. NOTE: The OpenManage Switch Administrator pages to configure IPv4 multicast routing and IPv6 multicast routing is very similar. The figures in this section show the IPv4 multicast configuration pages. To configure IPv6 multicast with PIM, use the pages available from the IPv6 Multicast → PIM menu. PIM Global Configuration Use the Global Configuration page to configure the administrative status of PIM-DM or PIM-SM on the switch. It is strongly recommended that IGMP be enabled on any switch on which IPv4 PIM is enabled and MLD be enabled on any switch for which IPv6 PIM is enabled. This ensures that the multicast router behaves as expected. The CLI behavior is different than the web interface. Enabling PIM on an IPv4 interface via the CLI automatically enables IGMP on the interface. Likewise, enabling PIM on an IPv6 interface via the CLI automatically enables MLD on the interface. To display the page, click IPv4 Multicast → PIM → Global Configuration or IPv6 Multicast → PIM → Global Configuration in the navigation panel. Figure 43-36. 1382 PIM-DM Global Configuration Managing IPv4 and IPv6 Multicast PIM Global Status Use the Global Status page to view the administrative status of PIM-DM or PIM-SM on the switch. To display the page, click IPv4 Multicast → PIM → Global Status or IPv6 Multicast → PIM → Global Status in the navigation panel. Figure 43-37. PIM Global Status Managing IPv4 and IPv6 Multicast 1383 PIM Interface Configuration Use the Interface Configuration page to configure specific VLAN routing interfaces with PIM. To display the page, click IPv4 Multicast → PIM → Interface Configuration or IPv6 Multicast → PIM → Interface Configuration in the navigation panel. Figure 43-38. 1384 PIM Interface Configuration Managing IPv4 and IPv6 Multicast PIM Interface Summary Use the Interface Summary page to display a PIM-enabled VLAN routing interface interface and its settings. To display the page, click IPv4 Multicast → PIM → Interface Summary or IPv6 Multicast → PIM → Interface Summary in the navigation panel. Figure 43-39. PIM Interface Summary Managing IPv4 and IPv6 Multicast 1385 Candidate RP Configuration The Candidate RP is configured on the Add Candidate RP page. Use the Candidate RP Configuration page to display and delete the configured rendezvous points (RPs) for each port using PIM. To access the page, click IPv4 Multicast → PIM → Candidate RP Configuration or IPv6 Multicast → PIM → Candidate RP Configuration. Figure 43-40. Candidate RP Configuration Adding a Candidate RP To add PIM Candidate rendezvous points (RPs) for each IP multicast group: 1 Open the Candidate RP Configuration page. 2 Click Add. The Add Candidate RP page displays. 1386 Managing IPv4 and IPv6 Multicast Figure 43-41. Add Candidate RP 3 Select the VLAN interface for which the Candidate RP is to be configured. 4 Enter the group address transmitted in Candidate-RP-Advertisements. 5 Enter the prefix length transmitted in Candidate-RP-Advertisements to fully identify the scope of the group which the router supports if elected as a Rendezvous Point. 6 Click Apply Changes. The new Candidate RP is added, and the device is updated. Managing IPv4 and IPv6 Multicast 1387 Static RP Configuration Use the Static RP Configuration page to display or remove the configured RP. The page also allows adding new static RPs by clicking the Add button. Only one RP address can be used at a time within a PIM domain. If the PIM domain uses the BSR to dynamically learn the RP, configuring a static RP is not required. However, you can configure the static RP to override any dynamically learned RP from the BSR. To access the page, click IPv4 Multicast → PIM → Static RP Configuration or IPv6 Multicast → PIM → Static RP Configuration. Figure 43-42. Static RP Configuration Adding a Static RP To add a static RP for the PIM router. 1 Open the Static RP Configuration page. 2 Click Add. The Add Static RP page displays. 1388 Managing IPv4 and IPv6 Multicast Figure 43-43. Add Static RP 3 Enter the IP address of the RP for the group range. 4 Enter the group address of the RP. 5 Enter the group mask of the RP. 6 Check the Override option to configure the static RP to override the dynamic (candidate) RPs learned for same group ranges. 7 Click Apply. The new Static RP is added, and the device is updated. Managing IPv4 and IPv6 Multicast 1389 SSM Range Configuration Use this page to display or remove the Source Specific Multicast (SSM) group IP address and group mask for the PIM router. To display the page, click IPv4 Multicast → PIM → SSM Range Configuration or IPv6 Multicast → PIM → SSM Range Configuration. Figure 43-44. SSM Range Configuration Adding an SSM Range To add the Source-Specific Multicast (SSM) Group IP Address and Group Mask (IPv4) or Prefix Length (IPv6) for the PIM router: 1 Open the SSM Range Configuration page. 2 Click Add. The Add SSM Range page displays. 1390 Managing IPv4 and IPv6 Multicast Figure 43-45. Add SSM Range 3 Click the Add Default SSM Range check box to add the default SSM Range. The default SSM Range is 232.0.0.0/8 for IPv4 multicast and ff3x::/32 for IPv6 multicast. 4 Enter the SSM Group IP Address. 5 Enter the SSM Group Mask (IPv4) or SSM Prefix Length (IPv6). 6 Click Apply. The new SSM Range is added, and the device is updated. Managing IPv4 and IPv6 Multicast 1391 BSR Candidate Configuration Use this page to configure information to be used if the interface is selected as a bootstrap router. To display the page, click IPv4 Multicast → PIM → BSR Candidate Configuration or IPv6 Multicast → PIM → BSR Candidate Configuration. Figure 43-46. 1392 BSR Candidate Configuration Managing IPv4 and IPv6 Multicast BSR Candidate Summary Use this page to display information about the configured BSR candidates. To display this page, click IPv4 Multicast → PIM → BSR Candidate Summary or IPv6 Multicast → PIM → BSR Elected Summary. Figure 43-47. BSR Elected Summary Managing IPv4 and IPv6 Multicast 1393 Configuring DVMRP (Web) This section provides information about the OpenManage Switch Administrator pages for configuring and monitoring DVMRP on a Dell Networking N2000, N3000, and N4000 series switches. For details about the fields on a page, click at the top of the page. DVMRP Global Configuration Use the Global Configuration page to configure global DVMRP settings. It is strongly recommended that IGMP be enabled on any switch on which DVMRP is enabled. The use cases for enabling DVMRP without IGMP are few, and enabling IGMP ensures that the multicast router behaves as expected. To display the page, click IPv4 Multicast → DVMRP → Global Configuration in the navigation panel. Figure 43-48. 1394 DVMRP Global Configuration Managing IPv4 and IPv6 Multicast DVMRP Interface Configuration Use the Interface Configuration page to configure a DVMRP VLAN routing interface. You must configure at least one router interface before you configure a DVMRP interface. Otherwise you see a message telling you that no router interfaces are available, and the configuration screen is not displayed. It is strongly recommended that IGMP be enabled on any interface on which DVMRP is enabled. This ensures that the multicast router behaves as expected. To display the page, click IPv4 Multicast → DVMRP → Interface Configuration in the navigation panel. Figure 43-49. DVMRP Interface Configuration Managing IPv4 and IPv6 Multicast 1395 DVMRP Configuration Summary Use the Configuration Summary page to display the DVMRP configuration and data for a selected interface. You must configure at least one VLAN routing interface before you can display data for a DVMRP interface. Otherwise you see a message telling you that no VLAN router interfaces are available, and the configuration summary screen is not displayed. To display the page, click IPv4 Multicast → DVMRP → Configuration Summary in the navigation panel. Figure 43-50. 1396 DVMRP Configuration Summary Managing IPv4 and IPv6 Multicast DVMRP Next Hop Summary Use the Next Hop Summary page to display the next hop summary by Source IP. To display the page, click IPv4 Multicast → DVMRP → Next Hop Summary in the navigation panel. Figure 43-51. DVMRP Next Hop Summary Managing IPv4 and IPv6 Multicast 1397 DVMRP Prune Summary Use the Prune Summary page to display the prune summary by Group IP. To display the page, click IPv4 Multicast → DVMRP → Prune Summary in the navigation panel. Figure 43-52. DVMRP Prune Summary DVMRP Route Summary Use the Route Summary page to display the DVMRP route summary. To display the page, click IPv4 Multicast → DVMRP → Route Summary in the navigation panel. Figure 43-53. 1398 DVMRP Route Summary Managing IPv4 and IPv6 Multicast Configuring L3 Multicast Features (CLI) This section provides information about the commands you use to configure general IPv4 multicast settings on the switch. For more information about the commands, see the Dell Networking N2000, N3000, and N4000 Series Switches CLI Reference Guide at support.dell.com/manuals. Configuring and Viewing IPv4 Multicast Information Beginning in Privileged EXEC mode, use the following commands to enable IPv4 multicast on the switch and to view and configure other general multicast settings. Command Purpose configure Enter global configuration mode. ip multicast Enable IPv4/IPv6 multicast on the switch. ip mroute source-address Create a static multicast route for a source range. mask rpf-address preference • source-address — The IP address of the multicast data source. • mask — The IP subnet mask of the multicast data source. • rpf-address — The IP address of the next hop towards the source. • preference — The cost of the route (Range: 1–255). interface vlan vlan-id Enter Interface Configuration mode for the specified VLAN. ip mcast boundary Add an administrative scope multicast boundary specified by the multicast group IP address (groupipaddr) and group IP subnet mask (mask) for which this multicast administrative boundary is applicable. groupipaddr mask The group IP address valid range is 239.0.0.0 to 239.255.255.255. ip multicast ttl-threshold ttlvalue Apply a Time to Live (TTL) value to the interface. The ttlvalue is the TTL threshold which is applied to the multicast data packets forwarded through the interface. Managing IPv4 and IPv6 Multicast 1399 Command Purpose exit Exit to Global Config mode. exit Exit to Privileged EXEC mode. show ip multicast View system-wide multicast information. show ip mcast boundary {vlan vlan-id | all} View all the configured administrative scoped multicast boundaries. show ip mcast mroute {detail | summary} View a summary or all the details of the multicast table. show mac address-table multicast [count] View information about the entries in the multicast address table. show ip mcast mroute View the multicast configuration settings such as flags, group groupipaddr {detail | timer settings, incoming and outgoing interfaces, RPF summary} neighboring routers, and expiration times of all the entries in the multicast mroute table containing the groupipaddr value. show ip mcast mroute source sourceipaddr {summary | groupipaddr} View the multicast configuration settings such as flags, timer settings, incoming and outgoing interfaces, RPF neighboring routers, and expiration times of all the entries in the multicast mroute table containing the sourceipaddr or sourceipaddr | groupipaddr pair value(s). show ip mcast mroute static View all the static routes configured in the static mcast [sourceipaddr ] table if it is specified or display the static route associated with the particular sourceipaddr. 1400 Managing IPv4 and IPv6 Multicast Configuring and Viewing IPv6 Multicast Route Information Beginning in Privileged EXEC mode, use the following commands to configure static IPv6 multicast routes on the switch and to view IPv6 multicast table information. Command Purpose configure Enter global configuration mode. ip multicast Enable IPv4/IPv6 multicast routing. ipv6 mroute source- Create a static multicast route for a source range. address/prefix-length rpf- • source-address/prefix-length — The IPv6 address of the address [interface vlan multicast data source. vlan-id] preference • rpf-address — The IPv6 address of the next hop towards the source. • vlan-id — If the rpf-address is a link-local address then the VLAN interface must also be specified. If the rpfaddress is a global address, then specifying the VLAN interface is not required. • preference — The cost of the route (Range: 1–255). exit Exit to Privileged EXEC mode. show ipv6 mroute {detail | summary} View a summary or all the details of the multicast table. show ipv6 mroute group View the multicast configuration settings such as flags, groupipaddr {detail | timer settings, incoming and outgoing interfaces, RPF summary} neighboring routers, and expiration times of all the entries in the multicast mroute table containing the groupipaddr value. show ipv6 mroute source View the multicast configuration settings such as flags, sourceipaddr {summary timer settings, incoming and outgoing interfaces, RPF | groupipaddr} neighboring routers, and expiration times of all the entries in the multicast mroute table containing the sourceipaddr or sourceipaddr | groupipaddr pair value(s). show ipv6 mroute static View all the static routes configured in the static mcast [sourceipaddr ] table if it is specified or display the static route associated with the particular sourceipaddr. Managing IPv4 and IPv6 Multicast 1401 Configuring and Viewing IGMP Beginning in Privileged EXEC mode, use the following commands to configure IGMP on the switch and on VLAN routing interfaces and to view IGMP information. Command Purpose configure Enter global configuration mode. ip multicast Enable IPv4/IPv6 multicast routing. ip igmp Enable IGMP on the switch. interface vlan vlan-id Enter Interface Configuration mode for the specified VLAN. ip igmp Enable IGMP on the interface. ip igmp version version Set the version of IGMP for an interface. The version variable can be 1, 2, or 3. ip igmp robustness robustness Configure the robustness that allows tuning of the interface, that is, tuning for the expected packet loss on a subnet. If a subnet is expected to have significant loss, the robustness variable may be increased for the interface. The range for robustness is 1–255. ip igmp query-interval seconds Configure the query interval for the specified interface. The query interval determines how fast IGMP HostQuery packets are transmitted on this interface. The range for seconds is 0–3600 seconds. ip igmp query-maxresponse-time seconds Configure the maximum response time interval for the specified interface. It is the maximum query response time advertised in IGMPv2 queries on this interface. The range for seconds is 0–25 seconds. ip igmp startup-queryinterval seconds Set the interval between general queries sent at startup on the interface. The range for seconds is 0–300 seconds. 1402 Managing IPv4 and IPv6 Multicast Command Purpose ip igmp startup-querycount count Set the number of queries sent out on startup —at intervals equal to the startup query interval for the interface. The range for count is 1–20. ip igmp last-memberquery-interval tenthsofseconds Configure the Maximum Response Time inserted in Group-Specific Queries which are sent in response to Leave Group messages. The range is 0–255 tenths of a second. ip igmp last-memberquery-count count Set the number of Group-Specific Queries sent before the router assumes that there are no local members on the interface. The range for count is 1–20. CTRL + Z Exit to Privileged EXEC mode. show ip igmp View system-wide IGMP information. show ip igmp interface [vlan vlan-id] View IGMP information for all interfaces or for the specified interface. show ip igmp interface stats [vlan vlan-id] View IGMP statistics for all interfaces or for the specified interface. show ip igmp groups [interface vlan vlan-id] View the registered multicast groups on the interface. show ip igmp membership View the list of interfaces that have registered in any multicast group. Managing IPv4 and IPv6 Multicast 1403 Configuring and Viewing IGMP Proxy Beginning in Privileged EXEC mode, use the following commands to configure the upstream VLAN routing interface as an IGMP proxy. The IGMP proxy issues host messages on behalf of the hosts that have been discovered on IGMP-enabled interfaces. The upstream interface is the interface closest to the root multicast router, which should be running IGMP. NOTE: Configure only the upstream interface as the IGMP proxy. IGMP should be enabled on all downstream interfaces. IP routing and IP multicast must be enabled on the switch for the IGMP proxy feature to operate. Command Purpose configure Enter global configuration mode. interface vlan vlan-id Enter Interface Configuration mode for the specified VLAN. ip igmp-proxy Configure the interface as an IGMP proxy interface. ip igmp-proxy reset-status (Optional) Reset the host interface status parameters of the IGMP Proxy. ip igmp-proxy unsolicit-rprtinterval seconds Configure the unsolicited report interval for the IGMP proxy interface. The range for seconds is 0–260 seconds. CTRL + Z Exit to Privileged EXEC mode. show ip igmp-proxy View a summary of the host interface status parameters. show ip igmp-proxy interface View a detailed list of the host interface status parameters. This command displays information only when IGMP Proxy is operational. show ip igmp-proxy groups View a table of information about multicast groups that IGMP Proxy reported. This command displays information only when IGMP Proxy is operational. 1404 Managing IPv4 and IPv6 Multicast Configuring and Viewing MLD Beginning in Privileged EXEC mode, use the following commands to configure MLD on the switch and on VLAN routing interfaces and to view IGMP information. Command Purpose configure Enter global configuration mode. ip multicast Enable IPv4/IPv6 multicast routing. ipv6 mld router Enable MLD on the switch. interface vlan vlan-id Enter Interface Configuration mode for the specified VLAN. ipv6 mld router Enable MLD on the interface. ipv6 mld version version Set the version of MLD for an interface. The version variable can be 1 or 2. ipv6 mld query-interval seconds Configure the query interval for the specified interface. The query interval determines how fast MLD Host-Query packets are transmitted on this interface. The range for seconds is 0–3600 seconds. ipv6 mld query-max-responsetime seconds Configure the maximum response time interval for the specified interface. It is the maximum query response time advertised in MLD queries on this interface. The range for seconds is 0–25 seconds. ipv6 mld last-member-queryinterval tenthsofseconds Set the last member query interval for the MLD interface, which is the value of the maximum response time parameter in the group-specific queries sent out of this interface. The range is 0–65535 milliseconds. ipv6 mld last-member-querycount count Set the number of listener-specific queries sent before the router assumes that there are no local members on the interface. The range for count is 1–20. CTRL + Z Exit to Privileged EXEC mode. Managing IPv4 and IPv6 Multicast 1405 Command Purpose show ipv6 mld interface [vlan vlan-id] View MLD information for all interfaces or for the specified interface. show ipv6 mld interface stats [vlan vlan-id] View MLD statistics for all interfaces or for the specified interface. show ipv6 mld groups [interface vlan vlan-id] View the registered multicast groups on the interface. show ipv6 mld membership View the list of interfaces that have registered in any multicast group. Configuring and Viewing MLD Proxy Beginning in Privileged EXEC mode, use the following commands to configure the upstream VLAN routing interface as an MLD proxy. The MLD proxy issues host messages on behalf of the hosts that have been discovered on the downstream MLD-enabled interfaces. The upstream interface is the interface closest to the root multicast router, which should be running IGMP. NOTE: Configure only the upstream interface as the MLD proxy. MLD should be enabled on all downstream interfaces. IPv6 routing must be enabled on the switch for the MLD proxy feature to operate. Command Purpose configure Enter global configuration mode. interface vlan vlan-id Enter Interface Configuration mode for the specified VLAN. ipv6 mld-proxy Configure the interface as an MLD proxy interface. ipv6 mld-proxy reset-status (Optional) Reset the host interface status parameters of the MLD Proxy. ipv6 igmp-proxy unsolicit-rprtinterval seconds Configure the unsolicited report interval for the MLD proxy interface. The range for seconds is 0–260 seconds. CTRL + Z 1406 Exit to Privileged EXEC mode. Managing IPv4 and IPv6 Multicast Command Purpose show ipv6 mld-proxy View a summary of the host interface status parameters. show ipv6 mld-proxy interface View a detailed list of the host interface status parameters. This command displays information only when MLD Proxy is operational. show ipv6 mld-proxy groups View a table of information about multicast groups that MLD Proxy reported. This command displays information only when MLD Proxy is operational. Configuring and Viewing PIM-DM for IPv4 Multicast Routing Beginning in Privileged EXEC mode, use the following commands to configure PIM-DM for IPv4 multicast routing on the switch and on VLAN routing interfaces and to view PIM-DM information. Command Purpose configure Enter global configuration mode. ip routing Enable ip routing. Routing is required for PIM to calculate where to prune the multicast trees. ip pim dense Enable PIM-DM on the switch. ip igmp Enable IGMP. IGMP is required for PIM to operate properly. ip multicast Enable IPv4/IPv6 multicast routing. interface vlan vlan-id Enter Interface Configuration mode for the specified VLAN. ip pim Enable PIM-DM on the interface. ip igmp Enable IGMP on the interface. IGMP is required for proper operation of PIMDM ip pim hello-interval seconds Specify the number of seconds (range: 0–65535) to wait between sending PIM hello messages on the interface. exit Exit to Privileged EXEC mode. show ip pim View system-wide PIM information. Managing IPv4 and IPv6 Multicast 1407 Command Purpose show ip pim interface vlan vlan-id View the PIM-DM information for the specified interface. show ip pim neighbor [interface vlan vlan-id | all] View a summary or all the details of the multicast table. Configuring and Viewing PIM-DM for IPv6 Multicast Routing Beginning in Privileged EXEC mode, use the following commands to configure PIM-DM for IPv6 multicast routing on the switch and on VLAN routing interfaces and to view PIM-DM information. Command Purpose configure Enter global configuration mode. ip routing Enable IP routing. Routing is required for PIM operation. ipv6 unicast-routing Enable IPv6 routing. IPv6 routing is required for the operation of PIM. ipv6 pim dense Enable PIM-DM on the switch. ip multicast Enable IPv6/IPv6 multicast routing. ip igmp Enable IGMP. IGMP is required for PIM to operate properly. interface vlan vlan-id Enter Interface Configuration mode for the specified VLAN. ipv6 pim Enable PIM on the interface. ipv6 enable Enable IPv6 on the VLAN. ipv6 mld router Enable MLD on the VLAN. MLD is required for PIM. ipv6 pim hello-interval seconds Specify the number of seconds (range: 0–65535) to wait between sending PIM hello messages on the interface. exit Exit to Privileged EXEC mode. show ipv6 pim View system-wide PIM information. 1408 Managing IPv4 and IPv6 Multicast Command Purpose show ipv6 pim interface vlan vlan-id View the PIM information for the specified interface. show ipv6 pim neighbor [interface vlan vlan-id | all] View a summary or all the details of the multicast table. Managing IPv4 and IPv6 Multicast 1409 Configuring and Viewing PIM-SM for IPv4 Multicast Routing Beginning in Privileged EXEC mode, use the following commands to configure PIM-SM for IPv4 multicast routing on the switch and on VLAN routing interfaces and to view PIM-SM information. Command Purpose configure Enter global configuration mode. ip routing Enable ip routing. Routing is required for PIM operation. ip pim sparse Enable PIM-SM as the multicast routing protocol on the switch. ip igmp Enable IGMP. ip multicast Enable IPv4/IPv6 multicast routing. ip pim bsr-candidate vlan Configure the switch to announce its candidacy as a bootstrap router (BSR). vlan-id hash-mask-length [priority] [interval interval] • vlan-id — A valid VLAN ID. • hash-mask-length — The length of a mask that is to be ANDed with the group address before the hash function is called. All groups with the same seed hash correspond to the same RP. For example, if this value is 24, only the first 24 bits of the group addresses matter. This allows you to get one RP for multiple groups. (Range 0–32 bits). • priority — The priority of the candidate BSR. The BSR with the higher priority is preferred. If the priority values are the same, the router with the higher IP address is the BSR. (Range 0–255). • interval — (Optional) Indicates the BSR candidate advertisement interval. The range is from 1 to 16383 seconds. The default value is 60 seconds. 1410 Managing IPv4 and IPv6 Multicast Command Purpose ip pim rp-candidate vlan Configure the router to advertise itself to the BSR vlan-id group-address group- router as a PIM candidate Rendezvous Point (RP) for mask [interval interval] a specific multicast group range. • vlan-id — A valid VLAN ID. • group-address — Group IP address supported by RP. • group-mask — Group subnet mask for group address. • interval — (Optional) Indicates the RP candidate advertisement interval. The range is from 1 to 16383 seconds. The default value is 60 seconds. ip pim rp-address rp-address (Optional) Statically configure the RP address for one group-address group-mask or more multicast groups. Only one RP address can be [override] used at a time within a PIM domain The optional keyword override indicates that if there is a conflict, the RP configured with this command prevails over the RP learned by BSR. ip pim ssm {default | group- Define the Source Specific Multicast (SSM) range of IP multicast addresses. address group-mask } • default — Defines the SSM range access list to 232.0.0.0/8. • group-address group-mask — defines the SSM range. interface vlan vlan-id Enter Interface Configuration mode for the specified VLAN. ip pim hello-interval seconds Specify the number of seconds (range: 0–65535) to wait between sending PIM hello messages on the interface. ip pim bsr-border Prevent bootstrap router (BSR) messages from being sent or received through the interface. ip pim dr-priority priority Set the priority value for which a router is elected as the designated router (DR). The election priority range is 0–2147483647. ip pim join-prune-interval Configure the interface join/prune interval for the PIM-SM router. The interval range is 0–18000 seconds. interval Managing IPv4 and IPv6 Multicast 1411 Command Purpose exit Exit to Global Config mode. exit Exit to Privileged EXEC mode. show ip pim View system-wide PIM information. show ip pim interface vlan View the PIM information for the specified interface. show ip pim neighbor [interface vlan vlan-id | all] View a summary or all the details of the multicast table. show ip pim rp-hash View the RP router being selected for the specified multicast group address from the set of active RP routers. The RP router for the group is selected by using a hash algorithm. show ip pim bsr-router [candidate | elected] View the bootstrap router (BSR) information. show ip pim rp mapping View group-to-RP mappings of which the router is aware (either configured or learned from the BSR) vlan-id groupaddr Configuring and Viewing PIM-SM for IPv6 Multicast Routing Beginning in Privileged EXEC mode, use the following commands to configure PIM-SM for IPv6 multicast routing on the switch and on VLAN routing interfaces and to view PIM-SM information. Command Purpose configure Enter global configuration mode. ip routing Enable IP routing. Routing is required for PIM operation. ipv6 unicast-routing Enable IPv6 routing. IPv6 routing is required for IPv6 PIM. ipv6 pim sparse Enable PIM-SM as the multicast routing protocol on the switch. ip mld router Enable MLD. MLD is required for the proper operation of IPv6 PIM. ip multicast Enable IPv4/IPv6 multicast. 1412 Managing IPv4 and IPv6 Multicast Command Purpose ipv6 pim bsr-candidate vlan Configure the switch to announce its candidacy as a bootstrap router (BSR) vlan-id hash-mask-length [priority] [interval interval] • vlan-id — A valid VLAN ID. • hash-mask-length — The length of a mask that is to be ANDed with the group address before the hash function is called. All groups with the same seed hash correspond to the same RP. For example, if this value is 24, only the first 24 bits of the group addresses matter. This allows you to get one RP for multiple groups. (Range 0–32 bits). • priority — The priority of the candidate BSR. The BSR with the higher priority is preferred. If the priority values are the same, the router with the higher IPv6 address is the BSR. (Range 0–255). • interval — (Optional) Indicates the BSR candidate advertisement interval. The range is from 1 to 16383 seconds. The default value is 60 seconds. ipv6 pim rp-candidate vlan Configure the router to advertise itself to the BSR vlan-id group-address/prefix- router as a PIM candidate Rendezvous Point (RP) for length [interval interval] a specific multicast group range. • vlan-id — A valid VLAN ID. • group-address/prefix-length— Group IPv6 address and prefix length supported by RP. • interval — (Optional) Indicates the RP candidate advertisement interval. The range is from 1 to 16383 seconds. The default value is 60 seconds. ipv6 pim rp-address rp- (Optional) Statically configure the RP address for one address group-address/prefix- or more multicast groups. Only one RP address can be used at a time within a PIM domain length [override] The optional keyword override indicates that if there is a conflict, the RP configured with this command prevails over the RP learned by BSR. Managing IPv4 and IPv6 Multicast 1413 Command Purpose ipv6 pim ssm {default | Define the Source Specific Multicast (SSM) range of group-address/prefix-length } IPv6 multicast addresses. • default — Defines the SSM range access list to FF3x::/32. • group-address/prefix-length — defines the SSM range. interface vlan vlan-id Enter Interface Configuration mode for the specified VLAN. ipv6 pim Enable PIM on the VLAN. ipv6 enable Enable IPv6 on the VLAN. ipv6 mld router Enable MLD on the VLAN. MLD is required for IPv6 PIM. ipv6 pim hello-interval Specify the number of seconds (range: 0–65535) to wait between sending PIM hello messages on the interface. ipv6 pim bsr-border Prevent bootstrap router (BSR) messages from being sent or received through the interface. ipv6 pim dr-priority priority Set the priority value for which a router is elected as the designated router (DR). The election priority range is 0–2147483647. seconds ipv6 pim join-prune-interval Configure the interface join/prune interval for the interval PIM-SM router. The interval range is 0–18000 seconds. exit Exit to Global Config mode. exit Exit to Privileged EXEC mode. show ipv6 pim View system-wide PIM information. show ipv6 pim interface vlan View the PIM information for the specified interface. vlan-id show ipv6 pim neighbor [interface vlan vlan-id | all] 1414 View a summary or all the details of the multicast table. Managing IPv4 and IPv6 Multicast Command Purpose show ipv6 pim rp-hash View the RP router being selected for the specified multicast group address from the set of active RP routers. The RP router for the group is selected by using a hash algorithm. show ipv6 pim bsr-router View the bootstrap router (BSR) information. show ipv6 pim rp mapping View group-to-RP mappings of which the router is aware (either configured or learned from the BSR) groupaddr Managing IPv4 and IPv6 Multicast 1415 Configuring and Viewing DVMRP Information Beginning in Privileged EXEC mode, use the following commands to configure DVMRP on the switch and on VLAN routing interfaces and to view DVMRP information. Command Purpose configure Enter global configuration mode. ip dvmrp Enable DVMRP on the switch. ip multicast Enable IP multicast. interface vlan vlan-id Enter Interface Configuration mode for the specified VLAN routing interface. ip dvmrp Enable DVMRP on the interface. ip dvmrp metric metric Configure the metric (range: 1–31) for an interface. This value is used in the DVMRP messages as the cost to reach this network. exit Exit to Privileged EXEC mode. show ip dvmrp interface View the multicast information for the specified interface. vlan vlan-id] show ip dvmrp neighbor View neighbor information for DVMRP. show ip dvmrp nexthop View the next hop information on outgoing interfaces for routing multicast datagrams. show ip dvmrp prune View the table that lists the router’s upstream prune information show ip dvmrp route View the multicast routing information for DVMRP. 1416 Managing IPv4 and IPv6 Multicast L3 Multicast Configuration Examples This section contains the following configuration examples: • Configuring Multicast VLAN Routing With IGMP and PIM-SM • Configuring DVMRP Configuring Multicast VLAN Routing With IGMP and PIM-SM This example describes how to configure a Dell Networking switch with two VLAN routing interfaces that route IP multicast traffic between the VLANs. PIM and IGMP are enabled on the switch and interfaces to manage the multicast routing. VLAN 10 is statically configured as the RP for the multicast group. NOTE: PIM does not require OSPF specifically; static routing or RIP could also be configured for unicast routing. The configuration in this example takes place on L3 switch A shown in Figure 43-54. The red arrows indicate the path that multicast traffic takes. L3 Switch A is configured as the RP for the PIM domain, so it is in charge of sending the multicast stream to L3 Switch B and L3 Switch C, and these switches forward the multicast data to the hosts that have requested to receive the data. Managing IPv4 and IPv6 Multicast 1417 Figure 43-54. IPv4 Multicast VLAN Routing Video Server L3 Switch A (PIM RP) Port 23 Port 24 L3 Switch B L3 Switch C IGMP Join IGMP Join ` ` ` VLAN 10 Members ` VLAN 20 Members In addition to multicast configuration, this example includes commands to configure STP and OSPF on L3 Switch A. STP is configured on the ports that connects the switch to other switches. OSPF is configured to route unicast traffic between the VLANs and PIM is enabled to rout multicast traffic between the two VLANs. Since IGMP snooping is enabled by default on all VLANs, no commands to enable it appear in the example below. To configure Switch A: 1 Create the two VLANs. IGMP/MLD Snooping is disabled globally. 1418 Managing IPv4 and IPv6 Multicast console#configure console(config)#no ip igmp snooping console(config)#no ipv6 mld snooping console(config)#vlan 10,20 console(config-vlan10,20)#exit 2 Configure port 23 and 24 as trunk ports. console(config)#interface te1/0/23 console(config-if-Te1/0/23)#switchport mode trunk console(config-if-Te1/0/23)#switchport trunk allowed vlan remove 10 console(config-if-Te1/0/23)#exit console(config)#interface te1/0/24 console(config-if-Te1/0/24)#switchport mode trunk console(config-if-Te1/0/24)#switchport trunk allowed vlan remove 20 console(config-if-Te1/0/24)#exit 3 Enable routing on the switch and configure the OSPF router ID. console(config)#ip routing console(config)#router ospf console(config-router)#router-id 3.3.1.1 console(config-router)#exit 4 Configure VLAN 10 as a VLAN routing interface and specify the OSPF area. When you assign an IP address to the VLAN, routing is automatically enabled. console(config)#interface vlan 10 console(config-if-vlan10)#ip address 192.168.10.4 255.255.255.0 console(config-if-vlan10)#ip ospf area 0 5 Enable IGMPv2 and PIM-SM on the VLAN routing interface. console(config-if-vlan10)#ip igmp console(config-if-vlan10)#ip igmp version 2 console(config-if-vlan10)#ip pim console(config-if-vlan10)#exit 6 Configure VLAN 20 as a VLAN routing interface and specify the OSPF area. console(config)#interface vlan 20 console(config-if-vlan20)#ip address 192.168.20.4 255.255.255.0 console(config-if-vlan20)#ip ospf area 0 7 Enable IGMPv2 and PIM-SM on the VLAN routing interface. console(config-if-vlan20)#ip igmp console(config-if-vlan10)#ip igmp version 2 console(config-if-vlan20)#ip pim Managing IPv4 and IPv6 Multicast 1419 console(config-if-vlan20)#exit 8 Globally enable IP multicast, IGMP, and PIM-SM on the switch. console(config)#ip multicast console(config)#ip igmp console(config)#ip pim sparse 9 Configure VLAN 10 as the RP and specify the range of multicast groups for PIM-SM to control. The 239.9.x.x address is chosen as it is a locally administered address that maps to MAC addresses that do not conflict with control plane protocols. console(config)#ip pim rp-address 192.168.10.4 239.9.0.0 255.255.0.0 1420 Managing IPv4 and IPv6 Multicast Configuring DVMRP The following example configures two DVMRP interfaces on the switch to enable inter-VLAN multicast routing. To configure the switch: 1 Globally enable IP routing and IP multicast. console#configure console(config)#ip routing console(config)#ip multicast 2 Globally enable IGMP so that this L3 switch can manage group membership information for its directly-connected hosts. Enabling IGMP is not required if there are no directly-connected hosts; however, it is recommended that it be enabled to ensure correct operation of multicast routing. Disable IGMP/MLD snooping. console(config)#ip igmp console(config)#no ip igmp snooping console(config)#no ipv6 mld snooping 3 Globally enable DVMRP. console(config)#ip dvmrp 4 Enable DVMRP and IGMP on VLAN routing interfaces 10 and 20. console(config)#interface vlan 10 console(config-if-vlan10)#ip address 192.168.10.1 255.255.255.0 console(config-if-vlan10)#ip dvmrp console(config-if-vlan10)#ip igmp console(config-if-vlan10)#exit console(config)#interface vlan 20 console(config-if-vlan20)#ip address 192.168.20.1 255.255.255.0 console(config-if-vlan20)#ip dvmrp console(config-if-vlan20)#ip igmp console(config-if-vlan20)#exit Managing IPv4 and IPv6 Multicast 1421 1422 Managing IPv4 and IPv6 Multicast A Feature Limitations and Platform Constants • Table A-1 lists the feature limitations and Table A-2 lists the platform constants for the Dell Networking switches. Table A-1. Feature Limitations Feature N2000 Series N3000 Series N4000 Series Base software features Link Dependency Max Groups 72 72 72 Number of monitor sessions 1 1 1 Max source ports in a session 624 624 816 Max Ether Stats entries 762 762 954 Max History entries 270 270 270 Max buckets per History entry 50 50 50 Max Alarm entries 32 32 32 Max Event entries 32 32 32 Max Log entries per Event entry 100 100 100 Management ACL (MACAL) Max Rules 64 64 64 Cut-through mode threshold (bytes) – – 768 Max Number of VPCs 127 127 127 Max Member ports per VPC 8 8 8 DCPDP UDP Port Number 50000 50000 50000 Switching features Port Mirroring RMON 1, 2, 3, 9 VPC Routing features Feature Limitations and Platform Constants 1423 Table A-1. Feature Limitations (Continued) Feature N2000 Series N3000 Series N4000 Series IP Helper Max entries 64 512 512 Max number of domains – – 8 Max number of MA's per domain – – 256 Max number of MA's – – 256 Max number of RMEP's – – 512 Max number LTR entries – – 256 HTTP Max Sessions 16 16 16 SSL/HTTPS Max Sessions 16 16 16 Max number of configured users 8 8 8 Max user name length 64 64 64 Max password length 64 64 64 Max number of IAS users (internal user database) 100 100 100 Max Count 5 5 5 Max methods per list 6 6 6 Max name length 15 15 15 Max Count 5 5 5 Max methods per list 6 6 6 Max name length 15 15 15 Metro Ethernet features Dot1ag Management features User management features User ID configuration Authentication login list Authentication Enable lists 1424 Feature Limitations and Platform Constants Table A-1. Feature Limitations (Continued) Feature N2000 Series N3000 Series N4000 Series Authentication HTTP lists Max Count 1 1 1 Max methods per list 6 6 6 Max name length 15 15 15 Max Count 1 1 1 Max methods per list 6 6 6 Max name length 15 15 15 Max Count 1 1 1 Max methods per list 6 6 6 Max name length 15 15 15 Max Count 5 5 5 Max methods per list 4 4 4 Max name length 20 20 20 Max Count 5 5 5 Max methods per list 4 4 4 Max name length 20 20 20 Max Count 5 5 5 Max methods per list 2 2 2 Max name length 15 15 15 Max Count 5 5 5 Max methods per list 1 1 1 Max name length 15 15 15 Authentication HTTPS lists Authentication Dot1x lists Authorization Exec lists Authorization Command lists Accounting Exec lists Accounting Commands lists Feature Limitations and Platform Constants 1425 Table A-1. Feature Limitations (Continued) Feature N2000 Series N3000 Series N4000 Series Login History 50 50 50 Max Monitored TCP Ports/IP Addresses 16 16 16 Max Sessions 1024 1024 252 Max Connections 1024 1024 252 Max physical units per stack 12 12 12 Max physical slots per unit 3 3 3 Max physical ports per slot 52 52 58 Max physical ports per unit 56 56 68 Max physical ports per stack 672 572 816 Max active stack ports per unit 2 2 8 QoS features iSCSI Stacking features 1426 Feature Limitations and Platform Constants Table A-2. Platform Constants Feature N2000 Series N3000 Series N4000 Series MAC addresses assigned per system 4 Reference CPU ARM Cortex ARM Cortex NetLogic A9 A9 XLP308L Reference CPU speed 1 GHz 1 GHz 1.2 GHz Reference RAM 1 Gbyte 1 Gbyte 2 Gbyte DDR3 Reference Flash 256 Mbyte 256 Mbyte 256 Mbyte Maximum number of remote Telnet connections 4 4 4 Maximum number of remote SSH connections 5 5 5 Number of MAC addresses supported 8192 16384 131072 Maximum Agetime in seconds 1000000 1000000 1000000 Number of VLANs 4096 4096 4096 Maximum VLAN ID 4093 4093 4093 Number of 802.1p traffic classes 7 7 7 Number of .1x clients per stack 2496 2496 2496 Number of .1x clients per port 64 64 64 Number of LAGs (max. lags/ports/max dynamic LAG ports per system 128/8/144 128/8/144 128/8/144 Maximum multiple spanning tree instances 15 15 15 Number of MAC-based VLANs supported 256 256 256 Number of network buffers 182 182 182 Number of records in log 400 400 400 4 4 IEEE 802.1x Feature Limitations and Platform Constants 1427 Table A-2. Platform Constants (Continued) Feature N2000 Series N3000 Series N4000 Series Static filter entries Unicast MAC and source port 1 1 1 Multicast MAC and source port 1 1 1 Multicast MAC and destination port (only) 1024 1024 2048 128 128 128 Max number of groups 128 128 128 Max protocols 16 16 16 1024 1024 2048 IGMPv3/MLDv2 HW entries when IP Multicast present 1024 1024 512 IGMPv3/MLDv2 HW entries when Routing w/o IP Multicast 4096 4096 2048 IGMPv3/MLDv2 HW entries when Switching only 8192 8192 4096 9216 9216 9216 Number of IP Source Guard stations 1020 1020 378 Number of DHCP snooping bindings 32768 32768 32768 1024 1024 Number of subnet-based VLANs supported Protocol-based VLANs Maximum MFDB entries IGMPv3/MLDv2 Snooping limits Jumbo frame support Max size supported Number of DHCP snooping static entries 1024 LLDP-MED 1428 Number of remote nodes 1296 1296 1632 LLDP Remote Management address buffers 1396 1396 1732 LLDP Unknown TLV address buffers 100 100 100 LLDP Organizationally Defined TLV buffers 8424 8424 10608 Feature Limitations and Platform Constants Table A-2. Platform Constants (Continued) Feature N2000 Series N3000 Series N4000 Series Port MAC locking Dynamic addresses per port 600 600 600 Static addresses per port 100 100 100 Number of samplers 672 672 816 Number of pollers 672 672 816 Number of receivers 8 8 8 Max Authentication servers 32 32 32 Max Accounting servers 32 32 32 512 12288 12288 IPv4 routes (–32 due to prefix length sharing) 256 8160 8160 IPv6 routes 128 4096 4096 RIP application route scaling 256 512 512 OSPF application route scaling N/A 8160 8160 256/128 1024/1024 1024/1024 Max OSPFv2 LSAs IPv4-only build IPv4/IPv6 build N/A N/A 37064 24680 36968 24680 OSPFv2 max neighbors N/A 400 400 Max OSPFv3 LSAs N/A 12488 12488 OSPFv2 max neighbors N/A 400 400 OSPFv3 max neighbors per interface N/A 100 100 sFlow RADIUS Number of routes (IPv4/IPv6) IPv4 only build (–32 due to prefix length sharing) IPv4/IPv6 build Number of static routes (IPv4/IPv6) OSPF Feature Limitations and Platform Constants 1429 Table A-2. Platform Constants (Continued) Feature N2000 Series N3000 Series N4000 Series Tunnels Number of configured v6-over-v4 tunnels N/A 8 8 Number of automatic (6to4) tunnels N/A 1 1 Number 6to4 next hops N/A 16 16 Max number of pools 16 16 16 Total max leases 256 256 256 Concurrent requests 16 16 16 Name server entries 8 8 8 Search list entries 6 6 6 Static host entries 64 64 64 Cache entries 128 128 128 Domain search list entries 32 32 32 Max number of pools 16 16 16 DNS domain names within a pool 5 5 5 DNS server addresses within a pool 8 8 8 Delegated prefix definitions within a pool 10 10 10 128 128 128 Device hardware capacity (v4/v6) 1024/512 16384/8192 8192/4086 IPv4-only build 1024 6144 6144 IPv4/IPv6 build (v4/v6) 1024/512 4096/1024 4096/1024 Static v4 ARP entries 128 128 128 Number of ECMP next hops per route 0 16 4 Number of ECMP groups 0 64 1024 DHCP server DNS client DHCPv6 Number of VLAN routing interfaces Number of ARP entries (Hosts) 1430 Feature Limitations and Platform Constants Table A-2. Platform Constants (Continued) Feature N2000 Series N3000 Series N4000 Series IP Multicast Number of IPv4/IPv6 Multicast Forwarding Entries N/A 2048 (1536 IPv4, 512 IPv6) 1024 (512 IPv4, 256 IPv6) IGMP Group Memberships per system N/A 2048 each for 2048 each for IPv4 and IPv4 and IPv6 IPv6 DVMRP Neighbors N/A 256 256 PIM-DM Neighbors N/A 256 256 PIM-SM Neighbors N/A 256 256 PIM-SM Static RP entries N/A 5 5 PIM-SM Candidate RP Group Range entries N/A 20 20 PIM-SM SSM range entries N/A 5 5 73 73 Maximum number of ACLs (any type) 100 100 100 Maximum number of configurable rules per list. 1023 1023 Maximum ACL Rules per Interface and 1023 ing., 1023 egr. Direction (IPv4/L2) 2048 ing., 1023 egr. 1023 ing., 1023 egr. Maximum ACL Rules per Interface and 1023 ing., 509 egr. Direction (IPv6) 1659 ing., 509 egr. 635 ing., 509 egr. 3914 3060 Maximum VLAN interfaces with ACLs 24 applied 24 24 Maximum ACL Logging Rules (system- 128 wide) 128 128 IGMP Sources processed per group per N/A message ACL limits Maximum ACL Rules (system-wide) 1023 3914 Feature Limitations and Platform Constants 1431 Table A-2. Platform Constants (Continued) Feature N2000 Series N3000 Series N4000 Series CoS Device Characteristics Configurable Queues per port (stacking/nonstacking) 7/8 7/8 7/8 Configurable Drop Precedence levels 3 3 3 Number of queues (stacking/nonstacking) 7/8 7/8 7/8 Max Rules per Class 13 13 13 Max Instances per Policy 12 12 12 Max Attributes per Instance 3 3 3 Max Service Interfaces (nonstacking/stacking) 184/800 184/800 196/944 Class Table 32 32 32 Class Rule Table 416 416 416 Policy Table 64 64 64 Policy Instance Table 768 768 768 Policy Attribute Table 2304 2304 2304 26 26 DiffServ Device Limits Max table entries Max Nested Class Reference Chain 26 Rule Count Datacenter Device Limits PFC number of lossless prioirities N/A N/A 2 ETS number of traffic class groups N/A N/A 3 AutoVoIP number of voice calls 16 16 16 Voice VLAN number of devices 672 672 816 1432 Feature Limitations and Platform Constants System Process Definitions B The following process/thread definitions are intended to assist the end user in troubleshooting switch issues. Only the most often seen threads/processes are listed here. Other processes or threads may be seen occasionally but are not a cause for concern. Table B-1. System Process Definitions Name Task Summary aclClusterTask ACL tasks aclEventTask aclLogTask ARP Timer ARP tasks autoInstTask Auto Install task - USB, etc. bcmATP-RX BCM system task: Acknowledged Transport Protocol bcmATP-TX bcmCNTR.0 BCM system task: SDK Statistics collection bcmDISC BCM system task: SDK Discovery task bcmDPC BCM system task: SDK DPC task bcmL2X.0 BCM system task: SDK L2 SOC shadow table maintenance bcmLINK.0 BCM system task: SDK Physical link status monitor bcmNHOP BCM system task: SDK transport Next Hop task bcmRLINK BCM system task:SDK Remote registration last bcmRPC BCM system task:SDK Remote registration last bcmRX BCM system task: SDK Control plane packet receiver/dispatcher bcmTUNQ BCM system task: SDK transport queueing task bcmTX BCM system task: SDK Control plane packet transmitter System Process Definitions 1433 Table B-1. System Process Definitions (Continued) Name Task Summary bcmXGS3AsyncTask BCM system task: SDK XGX3 hw task BootP Boot Loader boxs Req Box Services Request (temperature, power, fan) boxs Resp Box Services Response (temperature, power, fan) boxs Timer Box Services Response (temperature, power, fan) cdaFftpTask Code Distribution Administrator FTP task cdaStatusTask Code Distribution Administrator Status task cdaUpdateTask Code Distribution Administrator Update task cliWebIORedirectTask CLI Web IO Redirection Task cmgrInsertTask Card Manager Insertion Handler cmgrTask Card Manager Status (built-in and plug-in card configuration processing) Cnfgr_Thread Configurator (startup manager) CP Wired If Captive Portal cpuUtilMonitorTask CPU Utilities monitor DapiDebugTask Device API debug processing DHCP Server Processing Task DHCP Tasks DHCP snoop dhcpsPingTask DHCPv4 Client Task DHCPv6 Client Task DHCPv6 Server Task dnsRxTask DNS tasks dnsTask dosTask Denial of Service task dot1qTask VLAN routing task 1434 System Process Definitions Table B-1. System Process Definitions (Continued) Name Task Summary Dot1s transport task Spanning Tree tasks dot1s_helper_task dot1s_task dot1s_timer_task dot1xTask 802.1x authentication tasks dot1xTimerTask dot3ad_core_task Link aggregationt tasks dot3ad_core_ac_task dot3ad_helper_task dot3ad_timer_task dtlAddrTask Device Transform Layer - Silicon Integration Layer dtlTask dvmrpMapTask DVMRP Mapping Layer Dynamic ARP Inspection Dynamic ARP Inspection task EDB Entity MIB Processing task EDB Trap Entity MIB Trap task emWeb UI processing task envMonTask Environment Monitor (fans, power supplies, temperature, …) fdbTask Forwarding Data Base Manager fftpTask FTP processing gccp_t GARP Central Control Point task (dot 1d) System Process Definitions 1435 Table B-1. System Process Definitions (Continued) Name Task Summary hapiBpduTxTask High Level API - SDK Integration Layer hapiL2AsyncTask hapiL2FlushTask hapiL3AsyncTask hapiLinkStatusTask hapiMcAsyncTask hapiRxTask hapiTxTask hpcBroadRpcTask SDK Remote messaging task. ip6MapExceptionDataTask IP Stack ip6MapLocalDataTask ip6MapNbrDiscTask ip6MapProcessingTask ip6MapRadvdTask ipcom_sysl IpHelperTask ipMapForwardingTask ipMapProcessingTask ipnetd iscsiTask ISCSI task isdpTask ISDP task lldpTask LLDP task LOG System LOG processing LOGC System LOG processing MAC Age Task MAC address table aging MAC Send Task MAC address table learning macalTask Management ACL packet processing 1436 System Process Definitions Table B-1. System Process Definitions (Continued) Name Task Summary mcastMapTask Multicast Mapping Tasks mgmdMapTask mvrTask MVR Message Handler nim_t Network Interface Manager osapiMonTask System Task Monitor osapiTimer Application timer service osapiWdTask Hardware watchdog timer service OSPF mapping Task OSPF tasks OSPF Proto OSPFV3 mapping Task OSPFV3 recvmsg Task OSPFv3 Proto pimdmMapTask PIMDM task pimsmMapTask PIMSM task pingAsync Ping response processing pktRcvrTask Multicast control plane packet receiver/dispatch pmlTask Port MAC Locking management task portAggTask Port Aggregator task radius_rx_task RADIUS server tasks radius_task ripMapProcessingTask RIP Mapping layer RLIM cnfgr task VRRP configuration RLIM task VRRP message processing RMONTask RMON Statistics Collection serialInput Serial Input task sFlowTask sFlow task SimAddrConflictTask System Interface Manager Address Conflict Task System Process Definitions 1437 Table B-1. System Process Definitions (Continued) Name Task Summary simPts_task System Interface Manager (time zone, system name, service port config, file transfers, ...) SNMPCTTask SNMP Tasks SNMPSaveCfgTask SNMPTask SNMPTrapTask snoopTask IGMP/MLD Snooping packet processing SNTP SNTP tasks SNTPC spmTask Stack port manager - stacking control plane packet processing sshdEvTask SSH task ssltTask SSL task Stk Mgr Task Stack Manager Task tacacs_rx_task TACACS tasks tacacs_task tArpCallback ARP tasks tArpReissue tArpTimerExp ARP Timer Expiry tCpktSvc NSF Processing tCptvPrtl Captive portal control plane processing tDhcp6sTask DHCP Tasks tDhcpsTask tEmWeb Web page server tErfTask VxWorks Task tExcTask VxWorks Executive TimeRange Processing Task ACL Time Ranges tIomEvtMon 1438 CMC Communication System Process Definitions Table B-1. System Process Definitions (Continued) Name Task Summary tJobTask VxWorks Task tL7Timer0 System Timer tLogTask System LOG processing tNet0 VxWorks Network driver TransferTask TFTP Processing trapTask Trap handler tRipTask RIP Routing tRtrDiscProcessingTask Router Discovery packet processing tTffsPTask VxWorks True Flash File System driver tXbdService VxWorks flash file system load leveler usbFlashDriveTask USB Flash driver processing umCfgUpdateTask Stack Management: Unit Manager tasks umWorkerTask unitMgrTask USL Worker Task USL Message processing (primarily MAC address table CLI commands) UtilTask Mgmt. UI login/logout processing voipTask Voice Over IP VRRPdaemon VRRP task System Process Definitions 1439 1440 System Process Definitions Index Numerics 10GBase-T copper uplink module, 119 802.1p see CoS queuing address table. See MAC address table. administrative profiles, 213 defaults, 240 RADIUS authorization, 232 TACACS+ authorization, 228 alternate store and forward, 71 A Amber, 98, 110-111, 122-123 AAA, 207 ARP, 82 dynamic ARP inspection, 68 access lines, 239 access profiles, 63 accounting, 214 ACLs Auto-Voip usage, 1332 binding configuration, 609 CLI configuration, 612 configuration steps, 591 defined, 583 examples, 628 iSCSI usage, 461 limitations, 587 logging, 586 preventing false matches, 591 supported types, 67 web-based configuration, 599 ACLs. See also IP ACL, IPv6 ACL, and MAC ACL. active images, 368 ARP inspection. see DAI. ARP table configuring (CLI), 1080 configuring (web), 1070 authentication, 211 examples, 215 tiered, 578 authentication key, SNTP, 294 Authentication Manager, 578 authentication profiles, 63 authentication server filter assignments, 535 authorization, 212 administrative profiles, 213 examples, 227 RADIUS, 231 auto configuration auto save, 398 Index 1441 CLI configuration, 402 defaults, 400 defined, 389 DHCP, 405 configuration file, 395 image, 395 IP address, obtaining, 394 example, 403 files setup file, 392 USB, 390 files, managing, 398 IP address lookup, 391 MAC address lookup, 391 stopping, 398 using a USB device, 403 using DHCP, 393 web-based configuration, 401 auto image download DHCP, 405 USB, 403 auto install, 59 auto install. See auto configuration. auto negotiation, 72 auto save feature, 398 auto VoIP CLI configuration, 1335 defaults, 1332 understanding, 1331 web-based configuration, 1333 auto-provisioning, iSCSI, 463 Auto-VoIP and ACLs, 1332 1442 Index B back pressure, 72 banner, CLI, 315 baud rate, 120 BOOTP/DHCP relay agent, 83 BPDU filtering, 80, 722 flooding, 722 guard, 80 protection, 724 bridge multicast address groups, configuring, 818 bridge multicast group table, 817 bridge table, 1015 broadcast storm control. See storm control. C cable test, 243, 254 and green mode, 254, 484 captive portal, 65 CLI configuration, 568 client management, 573 configuring, 574 customizing pages, 546 defaults, 548 defined, 543 dependencies, 544 design considerations, 545 example, 574 localization, 547 understanding, 543, 546 user logout mode, 547 users, RADIUS server, 558 web-based configuration, 550 DHCP auto configuration, 395 downloading, 365 editing, 365 SNMP, 366 USB auto configuration, 392 USB device, 386 cards configuration, 301 supported, 303 configuration scripts, 365, 384 CDP, interoperability through ISDP, 60 Configuring, 1037 certificates, 363 CFM, 859 checkpointing, 179 Cisco protocol filtering, 76 CLI accessing the switch, 135 banner, 279 command completion, 140 command modes, 137 command prompt, 281 error messages, 141 negating commands, 140 configuration, saving the, 366 connectivity fault management. See IEEE 802.1ag. console port connecting to, 135 description, 120 Console Port Description, 94 copy, files, 374 commands abbreviated, 140 entering, 139 history buffer, 141 CoS and iSCSI, 460 and PFC, 985 CLI configuration, 1324 configuration example, 1328 defaults, 1316 defined, 1313 queue management methods, 1315 traffic queues, 1315 traffic shaping, 1314 trusted mode ports, 1314 untrusted mode ports, 1314 web-based configuration, 1318 Compellent storage arrays, 464 CoS queuing CLI banner, configuring, 315 clock, system, 292 command modes, CLI, 137 configuration file defined, 362 Index 1443 D DAI defaults, 885 optional features, 884 purpose, 885 understanding, 884 data center and DHCP snooping, 910 and NSF, 199 SDM template, 281 data center bridging exchange, 75 Data Center Bridging Exchange protocol, 992 date, setting, 311 daylight saving time, 280 DCBX and iSCSI, 464 DCBx, 992 default gateway, configuring, 149, 156 default VLAN, 163 DHCP client, 161 IP address configuration, 153 denial of service, 64, 582 device discovery protocols, 762 device view, 132 DHCP understanding, 1037 DHCP auto configuration dependencies, 399 1444 Index enabling, 405 monitoring, 398 process, 393 DHCP client, 1041 default VLAN, 161 OOB port, 161 DHCP relay, 76, 1041 CLI configuration, 1105 defaults, 1093 example, 1109 layer 2, 1088 layer 3, 1087 understanding, 1087 VLAN, 1089 web-based configuration, 1094 DHCP server, 57 address pool configuration, 1058 CLI configuration, 1054 defaults, 1042 examples, 1058 leases, 162 options, 1038 web-based configuration, 1043 DHCP snooping, 68, 1041 bindings database, 881 defaults, 885 example, 910 logging, 882 purpose, 885 understanding, 880 VLANs, 882 DHCPv6 client, 1250-1251 defined, 85 examples, 1281 pool, 1266 prefix delegation, 1266 relay agent, configuring, 1283 relay agent, understanding, 1266 stateless server configuring, 1281 stateless server, understanding, 1266 understanding, 1265 diffServ, 86 discovery, device, 761 document conventions, 52 domain name server, 157 domain name, default, 158 Dot1x, 66 dot1x authentication, 211 dhcpv6, 1265 double-VLAN tagging, 651 DHCPv6 pool stateless server support, 1277 downloading files, 370 DHCPv6 relay CLI configuration, 1277 defaults, 1267 web-based configuration, 1268 dual images, 58 DHCPv6 server CLI configuration, 1277 prefix delegation, 1282 web-based configuration, 1268 DVMRP, 89 defaults, 1355 example, 1421 understanding, 1353 web-based configuration, 1394 when to use, 1354 DHCPv6 server relay defaults, 1267 DiffServ and 802.1X, 511 and RADIUS, 511 and switch role, 1286 CLI configuration, 1300 defaults, 1287 elements, 1286 example, 1307 understanding, 1285 VoIP, 1310 web-based configuration, 1288 DSCP value and iSCSI, 461 dual IPv4 and IPv6 template, 281 Duplex mode, 94, 104 dynamic ARP inspection, 68 dynamic LAGs, 929 dynamic VLAN creation, 534 E EAP statistics, 422 email alert statistics, 266 email alerting, 276 Index 1445 and stacking, 366 downloading to the switch, 364 types, 359 uploading from the switch, 364 log messages, 272 enable authentication, 211 energy detect mode, 69, 478 Energy Efficient Ethernet, 69 energy savings, port, 478 enhanced transmission selection, 75, 999 EqualLogic and iSCSI, 463 error messages, CLI, 141 EtherType numbers, common, 592 exec authorization, 212 expansion slots, 284 filter assignments, authentication server, 535 filter, DiffServ, 511 firmware managing, 364 updating the stack, 177 upgrade example, 381 firmware synchronization, stacking, 177 Flashing Green, 99, 112, 124 failover, 62 flow control configuring, 798 default, 790, 984 port-based, 791 understanding, 788 failover, stacking, 179 flow-based mirroring, 1299 false matches, ACL, 591 forwarding database, 1015 and port security, 883 F FCoE configuring CoS queues for, 1329 file management CLI, 375 considerations, 364 copying, 374 purpose, 361 supported protocols, 363 web-based, 367 G GARP, 810 GARP and GVRP, 78 GMRP, 810 green Ethernet, 478, 483 file system, 367 green features, 69 files guest VLAN, 508 1446 Index VLAN guest, 533 GVRP, 650 statistics, 421 H Hardware description, 91, 102, 115 head of line blocking prevention, 71 health, system, 251 help, accessing web-based, 139 hierarchical authentication, 578 host name, 279 host name mapping, 148 I IAS database, 518 understanding, 511 users, 525 icons, web-based interface, 131 identification asset tag, 279 system contact, 279 system location, 279 system name, 279 IDSP defaults, 763 IEEE 802.1ag administrator, 863 carrier network, 860 configuration (CLI), 873 configuration (web), 865 defaults, 864 defining domains and ports, 863 example, 876 MEPs and MIPs, 861 troubleshooting tasks, 864 understanding, 859 IEEE 802.1d, 79 IEEE 802.1Q, 78 IEEE 802.1Qaz, 993 IEEE 802.1X, 66 and DiffServ, 511 authentication, 66 configuring, 525 defined, 504 monitor mode, 66, 509, 522 port authentication, 520 port states, 505 RADIUS-assigned VLANs, 523 reauthenticating ports, 514 VLAN assignment, 507 IEEE 802.1x authentication, 211 IEEE 802.3x. See flow control. IGMP, 89 defaults, 1355 understanding, 1341 web-based configuration, 1364 IGMP proxy, 89, 1341 Index 1447 IGMP snooping, 87 defaults, 814 querier, 88 querier, defined, 807 understanding, 805 image activating, 375 auto configuration, 395 auto install, 392 considerations, 364 defined, 359 downloading, 375 management, CLI, 375 management, web-based, 367 purpose, 361 default VLAN, 154, 163 OOB port, 163 IP helper, 83, 1089 IP multicast traffic layer 2, 804 layer 3, 1338 IP protocol numbers, common, 592 IP routing CLI configuration, 1079 defaults, 1065 example, 1084 understanding, 1063 web-based configuration, 1067 in-band management, 149 IP source guard, 67 interface, 1021 configuration mode, 481 loopback, 1022 OOB, 152 routing, 1021 CLI configuration, 1033 web configuration, 1027 routing defaults, 1026 supported types, 481 tunnel, 1023 IPSG and port security, 883 example, 912 purpose, 885 understanding, 883 internal authentication server, see IAS IP ACL configuration, 599 defined, 585 IP address configuring, 149 default, 151 1448 Index IPv4 and IPv6 networks, interconnecting, 1187 IPv4 multicast web-based configuration, 1357 IPv4 routing template, 281 IPv6 compared to IPv4, 1242 DHCP client, 1250-1251 DHCPv6, 85 OSPFv3, 85 routes, 85 static reject and discard routes, 1263 CLI configuration, 777 configuring, 778 enabling, 778 example, 782 understanding, 761 web-based configuration, 765 tunnel, 84 IPv6 ACL configuration, 606 IPv6 interface configuring, 1242 IPv6 management, 58 IPv6 multicast web-based configuration, 1363 IPv6 routing CLI configuration, 1256 defaults, 1243 features, 85 understanding, 1241 web-based configuration, 1245 IRDP, configuring, 1081 iSCSI ACL usage, 461 and Compellent storage arrays, 464 and CoS, 460 and DCBX, 464 and Dell EqualLogic arrays, 463 assigning flows, 460 CLI configuration, 471 defaults, 466 examples, 473 flow detection, 460 information tracking, 462 servers and a disk array, 473 understanding, 459 using, 460 web-based configuration, 467 ISDP and CDP, 60 J jumbo frames, 71 L LACP, 81 adding a LAG port, 922 CLI configuration, 927 web-based configuration, 920 LAG and STP, 916 CLI configuration, 925 defaults, 917 examples, 929 guidelines, configuration, 916 interaction with other features, 916 LACP, 81 purpose, 914 static and dynamic, 914 statistics, 436 threshold, minimum links, 925 understanding, 913 web-based configuration, 918 LAG hashing, 915 languages, captive portal, 547 Index 1449 LED 100/1000/10000Base-T port, 97, 109, 121 port, 119 SFP port, 97, 109, 121 system, 98, 110, 122 link aggregation group. See LAG. link dependencies CLI configuration, 497-498 creating, 489 example, 501 scenarios, 480 understanding, 479 web configuration, 489 link local protocol filtering, see LLPF LLDP CLI configuration, 777 defaults, 763 example, 783 understanding, 761 web-based configuration, 765 LLDP-MED and voice VLANs, 654 configuring, 781 understanding, 762 viewing information, 782 LLPF defaults, 790, 984 example, 801 understanding, 789 localization, captive portal, 547 locating the switch, 133 1450 Index locator LED enabling, 133, 267 log messages, 57 log server, remote, 260 logging ACL, 586 CLI configuration, 267 considerations, 247 defaults, 248 destination for log messages, 244 example, 274 file, 259 log message format, 246 operation logs, 245 severity levels, 245 system startup logs, 245 trap log, 343 web-based configuration, 249 loopback, 84 loopback interface configuring, 1035 purpose, 1025 understanding, 1022 low-power idle, 483 LSA, OSPF, 1113 M MAC ACL understanding, 584 MAC address table and port security, 883 contents, 1016 defaults, 1016 defined, 1015 dynamic, 1019 managing, CLI, 1020 populating, 1015 stacking, 1016 web-based management, 1017 MAC multicast support, 87 MAC port locking, 540 MAC-based 802.1X authentication understanding, 506 MAC-based VLAN, 648 mail server adding, 263 configuring, 271 email alert, 262 management access control using RADIUS, 232 access control using TACACS+, 237 management, in-band and out-of-band, 149 MD5, 283 MDI/MDIX, auto, 72 MEP, configuring, 874 MIB, SNMP, 323 Microsoft Network Load Balancing, 1354 mirror, ACL, 585 mirroring, flow-based, 1299 MLAG, 932 MLD, 90 defaults, 1355 understanding, 1342 web-based configuration, 1373 MLD snooping, 88 defaults, 814, 885 understanding, 807 VLAN configuration, 849 mode interface configuration, 481 monitor mode, IEEE 802.1X, 509 monitoring system information, 243 MSTP example, 753 operation in the network, 717 support, 79 understanding, 715 MTU, configuring, 497 MTU, management interface, 150 Multicast VLAN registration, 88 multicast DVMRP, 89 IGMP, 89 IGMP proxy, 89 IGMP snooping, 87 IPv4, 1357 layer 2, 87 configuring (CLI), 846 Index 1451 configuring (web), 816 defaults, 814 understanding, 803 when to use, 809 layer 3, 89 CLI configuration, 1399 defaults, 1355 examples, 1417 understanding, 1337 when to use, 1340 MAC layer, 87 MLD snooping, 88 protocols roles, 1339-1340 VLAN Routing with IGMP and PIM-SM, 1417 multicast bridging, 804, 846 multicast protocols, supported, 1339 multicast routing table, 1341 network information CLI configuration, 161 default, 151 defined, 147 example, 166 purpose, 148 web-based configuration, 152 network pool, DHCP, 1046 nonstop forwarding, see NSF NSF and DHCP snooping, 201 and routed access, 204 and the storage access network, 202 and VoIP, 200 in the data center, 199 network design considerations, 181 understanding, 178 multicast snooping, 854 multicast VLAN registration, 808 MVR adding an interface, 838 OAM, 859 OOB port, 119-120, 152 DHCP client, 161 OpenManage Switch Administrator, about, 127 N N2000 back panel, 95 N2000 Port Description, 91 N3000 back panel, 106 N3000 Port Description, 102 netinfo, 147 1452 O Index optical transceiver diagnostics, 255 OSPF, 82 areas, 1112 border router, 1177 CLI configuration, 1155 defaults, 1120 difference from OSPFv3, 1113 examples, 1177 flood blocking, 1118, 1195 LSA pacing, 1117 NSSA, 1180 static area range cost, 1116, 1190 stub area, 1180 stub routers, 1114 topology, 1112 trap flags, 341 understanding, 1112 web-based configuration, 1122 OSPFv3, 85 CLI configuration, 1167 difference from OSPF, 1113 global settings, 1167 interface settings, 1169 NSSA, 1180 stub area, 1180 trap flags, 342 web-based configuration, 1138 out of band port, IP address, 163 out-of-band management, 149 P password protecting management access, 63 strong, 63 PFC, 985 PIM defaults, 1355 IPv4 web-based configuration, 1382 IPv6 web-based configuration, 1382 PIM-DM, using, 1352 PIM-SM, using, 1343 SSM range, 1390 understanding, 1343 plug-in modules configuring, 284 PoE+, 285, 313 policy based routing (PBR), 594 port access control, 516 characteristics, 477 configuration examples, 500 configuring multiple, 487 defaults, 485 defined, 477 device view features, 132 example, 500 LEDs, 119 locking, 540 OOB, 119-120 power saving, 483 protected, 68, 794, 799 statistics, 435 traffic control, 787, 983 USB, 119 port characteristics CLI configuration, 496 web-based configuration, 486 port control, 515 port fast, STP, 722 Index 1453 Port LEDs, 97, 109, 121 Q port mirroring configuring, 437 mode, enabling, 412 understanding, 411 QoS CoS queuing diffserv, 86 port security configuring, 542 MAC-based, 66 understanding, 539 port-based flow control, 791 port-based traffic control, 787 CLI configuration, 798, 992 web-based configuration, 791 port-based VLAN, 648 port-channel. See LAG. port-MAC locking, 66 see port security power supplies, 120 power utilization reporting, 69 power, per-port saving modes, 483 QSFP module, 118 queues, CoS, 1315 R RADIUS, 64 and DiffServ, 511 authentication, 225 authorization, 231-232 for management access control, 232 supported attributes, 234 understanding, 232 RAM log, 258 real time clock, 280 redirect, ACL, 585 relay agent, DHCPv6, 1266 priority flow control, 985 relay, DHCP, 1087 priority-based flow control, 74, 985 remote logging, 270 private VLAN edge, 68 private VLANs, 654, 711 protected port defined, 789 example, 801 protocol filtering, Cisco, 76 protocol-based VLAN, 648 1454 Index RIP, 83 CLI configuration, 1209 defaults, 1203 determining route information, 1201 example, 1213 supported versions, 1202 understanding, 1201 web-based configuration, 1204 RMON, 60 CLI management, 439 defaults, 414 example, 449 understanding, 410 web-based configuration, 414 router discovery, 1081 router discovery protocol, 83 router, OSPF, 1113 routes IPv4, 1077 IPv6, 1255 selecting, 1113 Routing table, 83 routing defaults (IPv4), 1065 defaults (IPv6), 1243 example, 1084 IPv4, CLI configuration, 1079 IPv4, web-based configuration, 1067 IPv6, CLI configuration, 1256 IPv6, web-based configuration, 1245 understanding, 1063 routing interfaces CLI configuration, 1033 defaults, 1026 understanding, 1021 using, 1024 web-based configuration, 1027 routing table best routes, 1074 configuring, 1082 IPv6, 1260, 1262 RSPAN, 73, 411 RSTP understanding, 715 RSTP-PV, 724 running-config, saving, 366 S save, system settings, 366 SDM template configuration guidelines, 283 managing, 309 understanding, 281 SDM templates, 58 security port, defined, 539 port-based CLI configuration, 520 defaults, 511, 539 examples, 525 web-based configuration, 512 setup file format, auto configuration, 392 sFlow, 59 CLI management, 439 defaults, 414 example, 447 understanding, 407 web-based management, 414 Index 1455 SFP port LEDs, 97, 109, 121 SSL files, 363 SFP+ module, 118 SSM range, 1390 SFTP, managing files, 380 stacking adding a switch, 176 and NSF, 62 CLI configuration, 192 defaults, 182 defined, 171 design consideration, 181 failover, 62 failover, example, 195 failover, initiating, 179 features, 61 file management, 366 firmware synchronization, 177 firmware update, 177 MAC address table, 1016 MAC addresses, 181 NSF usage scenario, 195 preconfiguration, 197 purpose, 182 removing a switch, 177 standby, 178 switch compatibility, 174 web-based configuration, 184 slots, 284 SNMP CLI configuration, 345 defaults, 325 examples, 354 MIB, 323 purpose, 325 traps, 324 understanding, 323 uploading files, 366 web-based configuration, 327 SNMPv1 example, 354 SNMPv2 example, 354 SNMPv3 engine ID, 345 example, 355 SNTP authentication, 309 authentication key, 294 example, 319 server, 309 server configuration, 296 understanding, 283 software image, 359 spanning tree. See STP. split horizon, 1202 SSH files, 363 SSH/SSL, 64 1456 Index static reject route, 1064 statistics IPv6, 1248 statistics, Etherlike, 420 storage arrays and iSCSI, 463 storage arrays, Compellent, 464 storm control configuring, 798 default, 790, 984 example, 801 understanding, 788 STP and LAGs, 916 classic, 715 CLI configuration, 746 defaults, 735 defined, 715 examples, 751 loop guard, 723 MSTP, 79 optional features, 722 port fast, 722 port settings, 79 root guard, 723 RSTP, 79 understanding, 716 web-based configuration, 736 web-based configuration, 287 system LEDs, 119 system time, 283 T TACACS+, 63 authentication, 217 authorization, 227-228 management access control, 237 supported attributes, 238 understanding, 237 tagging, VLAN, 649 Telnet configuration options, 64 connecting to the switch, 136 TFTP, image download, 375 STP-PV, 724 tiered authentication, 578 subnet mask, configuring, 149 time domain reflectometry, 254 subnet-based VLAN, 648 time management, 56 summer time, 280 time range, 626 switchport modes, VLAN, 648 time zone, 300 switchport statistics, web view, 425 time, setting the system, 321 system health, monitoring, 249 traffic class queue, 460 system information CLI configuration, 307 default, 286 defined, 279 example, 315 purpose, 281 traffic control port based, 787, 983 time-based ACLs, 586 traffic inspection, 879 traffic monitoring, 407 traffic snooping, 879 Index 1457 traps OSPF, 341 trunk port and 802.1X authentication, 533, 535 trunking, 683 tunnel, 84 tunnel interfaces, 1023 U UDP relay, 83, 1089 uploading files, 372 USB auto configuration example, 403 files, 390-391 understanding, 390 USB flash drive, example, 386 USB port, 119 user security model, SNMP, 324 users authenticated, 515 captive portal, 556 IAS database, 511 USM, 324 VLAN, 916 authenticated and unauthenticated, 507 CLI configuration, 682 defaults, 661 double, 78 double-VLAN tagging, 651 dynamic, 508 example, 701, 706 guest, 78, 508, 534 IP subnet-based, 77 MAC-based, 77, 648 port-based, 77, 648 private, 654, 711 protocol-based, 77, 648 RADIUS-assigned, 534 routing, 82 routing interfaces, 1021, 1033 static, 648 support, 77 switchport modes, 648 trunk port, 683 understanding, 645 voice, 78, 653 voice traffic, 653 voice, example, 710 voice, understanding, 652 web-based configuration, 663 VLAN membership, defining, 663 V VLAN priority tag and iSCSI, 461 Ventilation System, 96 VLAN routing, 1021, 1024 ventilation system, 121 VLAN tagging, 649 virtual link, OSPF, 1184 1458 Index VLANs dynamically created, 534 RADIUS-assigned, 534 voice traffic, identifying, 653 voice VLAN, 653 and LLDP-MED, 654 example, 710 understanding, 652 VoIP, 86 VoIP and DiffServ, 1310 VoIP, auto, 1331 VRRP, 84 accept mode, 1219 CLI configuration, 1230 defaults, 1221 example, 1232 interface tracking, 1219 load sharing example, 1232 preemption, 1218 route and interface tracking example, 1236 route tracking, 1219 router priority, 1218 understanding, 1217 web-based configuration, 1222 W web-based configuration, 128 web-based interface, understanding, 129 writing to memory, 366 Index 1459 Index 1460


Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
Format                          : application/pdf
Creator                         : Dell Inc.
Subject                         : Deployment Guide9
Description                     : Deployment Guide9
Title                           : Dell Networking N2000 Series User's Guide
Producer                        : Acrobat Distiller 9.4.2 (Windows); modified using iTextSharp 5.1.3 (c) 1T3XT BVBA
Keywords                        : Servers, Storage, & Networking#Networking#Blade InterconnectsChassis SwitchesFixed Port SwitchesNetworking SoftwareWireless##networking n2000 series#networking-n2000-series#Deployment Guide9#Dell Networking N2000# N3000# and N4000 Series Switches
Create Date                     : 2014:01:14 13:17:32Z
Creator Tool                    : FrameMaker 10.0.2
Modify Date                     : 2014:06:18 18:00:50-05:00
Page Mode                       : UseOutlines
Page Count                      : 1460
Author                          : Dell Inc.
Businesskeywords                : Dell Networking N2000# N3000# and N4000 Series Switches
Categorypathforfutureproducts   : 
Creationdate                    : D:20140114131732Z
Expirydate                      : 9999-09-09 00:00:00
Filesize                        : 32449
Futureproductindication         : No
Isdeleted                       : False
Isrestricted                    : False
Languagecodes                   : en-us
Manualurl                       : ftp://ftp.dell.com/Manuals/all-products/esuprt_ser_stor_net/esuprt_networking/esuprt_net_fxd_prt_swtchs/networking-n2000-series_Deployment%20Guide9_en-us.pdf
Moddate                         : D:20140618151416-05'00'
Productcode                     : networking-n2000-series
Productpath                     : esuprt_net_fxd_prt_swtchs
Publishdate                     : 2014-06-18 00:00:00
Readytocopy                     : false
Typecode                        : dg9
Typedescription                 : Deployment Guide9
EXIF Metadata provided by EXIF.tools

Navigation menu