Dell Force10
S4820T System

Getting Started Guide
Publication Date: December 2012

Regulatory Model: S4820T

Notes, Cautions, and Warnings
NOTE: A NOTE indicates important information that helps you make better use
of your computer.
CAUTION: A CAUTION indicates potential damage to the hardware or loss
of data if you do not follow the instructions.
WARNING: A WARNING indicates a potential for property damage,
personal injury, or death.

If you purchased a Dell n Series computer, any references in this publication to
Microsoft Windows operating systems are not applicable.
____________________
Information in this publication is subject to change without notice.
© 2012 Dell Inc. All rights reserved.
Reproduction of these materials in any manner whatsoever without the written permission of Dell Inc.
is strictly forbidden.
Trademarks used in this text: Dell™, the DELL logo, Dell Precision™, OptiPlex™, Latitude™,
PowerEdge™, PowerVault™, PowerConnect™, OpenManage™, EqualLogic™, KACE™,
FlexAddress™ and Vostro™ are trademarks of Dell Inc. Intel®, Pentium®, Xeon®, Core™ and
Celeron® are registered trademarks of Intel Corporation in the U.S. and other countries. AMD® is a
registered trademark and AMD Opteron™, AMD Phenom™, and AMD Sempron™ are trademarks
of Advanced Micro Devices, Inc. Microsoft®, Windows®, Windows Server®, MS-DOS® and
Windows Vista® are either trademarks or registered trademarks of Microsoft Corporation in the United
States and/or other countries. Red Hat Enterprise Linux® and Enterprise Linux® are registered
trademarks of Red Hat, Inc. in the United States and/or other countries. Novell® is a registered
trademark and SUSE ™ is a trademark of Novell Inc. in the United States and other countries. Oracle®
is a registered trademark of Oracle Corporation and/or its affiliates. Citrix®, Xen®, XenServer® and
XenMotion® are either registered trademarks or trademarks of Citrix Systems, Inc. in the United States
and/or other countries. VMware®, Virtual SMP®, vMotion®, vCenter®, and vSphere® are registered
trademarks or trademarks of VMWare, Inc. in the United States or other countries.
Other trademarks and trade names may be used in this publication to refer to either the entities claiming
the marks and names or their products. Dell Inc. disclaims any proprietary interest in trademarks and
trade names other than its own.
Regulatory Model: S4820T
2012 - 12

P/N 0JF15T

Rev. A00

Contents
1

About this Guide .

. . . . . . . . . . . . . . . . . . . . . . . .

1

2

Introduction .

. . . . . . . . . . . . . . . . . . . . . . . . . . .

3

Product Description .

3

Hardware Overview
Fans

. . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Front Panel

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

System Status

4

. . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Installation .

. . . . . . . . . . . . . . . . . . . . . . . . . . . .

Unpacking the Switch

6
7
8

11
11

. . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . .

11
11

. . . . . . . . . . . . . . . . . . . . . . . . . . . .

12

Install an AC or DC Power Supply
Rack Mounting the Switch

. . . . . . . . . . . . . . . . . .

13

. . . . . . . . . . . . . . . . . . . . . .

14

Rack Mounting Safety Considerations.
Installing the Dell ReadyRails System .
Installing the Switch . . . . . . . . . .

5

5

. . . . . . . . . . . . . . . . . . . . . . . .

Package Contents
Unpacking Steps .
Power Supplies

3

. . . . . . . . . . . . .

14
15
19

. . . . . . . . . . . . . . . . . .

21

. . . . . . . . . . . . . . . . . . . . . . .

21

Technical Specifications .
Chassis Physical Design

. . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . .

21

. . . . . . . . . . . . . . . . . . . . . . . . .

22

Environmental Parameters
Power Requirements

. . . . . . . . . . . . .

DC Input Specification .

. . . . . . . . . . . . . . . . . . . . .

Contents

22

1

Contents
IEEE Standards .

6

. . . . . . . . . . . . . . . . . . . . . . . . . . . .

Performing the Initial Configuration

. . . . . . . . . . .

25

. . . . . . . . . . . . . . . . . . . . . . . .

25

. . . . . . . . . . . . . . . . . . . . . . . . . . . .

25

Navigating CLI Modes .
Console Access

Default Configuration

. . . . . . . . . . . . . . . . . . . . . . . . .

Configure Layer 2 (Data Link) Mode.
Configure a Host Name

27

. . . . . . . . . . . . . . . . . . . . . . . .

27

. . . . . . . . . . . . . . . . . . . . .

Configure the Management Port IP Address
Configure the Management Route . . . . . .
Configure the Username and Password . . .

Create a Port-based VLAN.

28

. . . . . . . . . .

28
29
29

. . . . . . . . . . . . . . . . . . .

29

. . . . . . . . . . . . . . . . . . . . . .

30

Configure the Enable Password .

Assign Interfaces to a VLAN . . .
Assign an IP Address to a VLAN .

. . . . . . . . . .
. . . . . . . . . .

. . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . .

Connecting the S4820T to the Network .

Contents

27

. . . . . . . . . . . . . . . . .

Access the System Remotely

2

23

. . . . . . . . . . . . . . .

30
32
32

Contents

Contents

3

Contents

4

Contents

About this Guide
This document is intended as a Getting Started Guide to get new systems up and
running and ready for configuration. For complete installation and configuration
information, refer to the documents listed in Table 1-1.
Table 1-1. S4820T Documents
Information

Documentation

Hardware installation and power-up
instructions

Installing the S4820T System

Software configuration

FTOS Configuration Guide for the S4820T
System

Command line interface

FTOS Command Line Reference Guide for
the S4820T System

Latest updates

FTOS Release Notes for the S4820T System

About this Guide

1

2

About this Guide

1
Introduction
This document provides basic information about the S4820T switch,
including how to install the switch and perform the initial configuration. For
information about how to configure and monitor switch features, refer to the
User’s Configuration Guide, which is available on the Dell Support website at
support.dell.com/support.
This document contains the following sections:
•

Hardware Overview

•

Installation

•

Technical Specifications

•

Performing the Initial Configuration

Product Description
S4820T is a top-of-rack (ToR) switch/router product for copper connections to
10G servers and 40Gbps uplinks to the 40G switching fabric in the core. The
S4820T has 48 ports of 10GBase-T and four ports of 40Gbps with features and
functions similar to the S4810 product.
The S4820T switch runs the Dell Force10 Operating System (FTOS), providing
switching, bridging, and routing functionality for transmitting data, storage, and
server traffic.
In a data center network, the S4820T switch provides converged network
support and interoperates with Dell and third-party ToR devices. The switch
supports data center bridging (DCB) features and optimizes connectivity
between servers and storage devices using Fibre Channel over Ethernet
(FCoE) and Internet Small Computer System Interface (iSCSI) links.
By providing increased 40GbE bandwidth for device interconnection in a
shared network storage environment, with the possibility of splitting 40GbE
Quad Small Form-Factor Pluggable Plus (QSFP+) uplinks into 10GbE SFP+
connections, the S4820T switch is perfectly positioned to help transition a
data center with multiple speed requirements.

Introduction

3

The S4820T solution is optimized to provide 10Gbps throughput for distances
of up to:

4

•

330 feet (100 meters) over Cat6, 6A, and 7 shielded copper cable and
Cat6A UTP copper cable

•

181.5 feet (55 meters) over Cat6 UTP copper cable

Introduction

Hardware Overview
This section contains information about device characteristics and modular
hardware configurations for the S4820T switch.
The S4820T has the following physical dimensions:
•

434 x 460 x 43.5 mm (W x D x H).

•

17.09 x 18.11 x 1.71 inches (W x D x H).

The S4820T has a chassis design with 640Gbps switching bandwidth as listed
below:
•

S4820T = 48 port 10GBase-T + 4 port 40G QSFP+

The system also provides one RS-232 interface RJ-45 YOST console port and
a dedicated Ethernet service port for out-of-band (OOB) management
functions.
The S4820T has the following features:
•

Supports one universal serial bus (USB) port

•

Forty-eight 10Gbps ports

•

Four fixed 40Gbps QSFP ports for a 40Gbps transceiver

•

On-board high-performance central processing unit (CPU) system with
large memory, P2020/128 MB NOR Flash/2GB DDR III RAM.

•

Temperature monitoring (TMP75)

•

Software-readable thermal monitor

•

Real time clock (RTC) support

•

Hot-plugging redundant power supply

•

Current monitoring for Power management

•

Removable fan that you can manage

•

Standard 1U chassis high

Hardware Overview

5

Fans
The S4820T has stock keeping units (SKUs) that support the following
configurations. Installation of the fans is done as part of the factory install based
on SKU type. The power supply units (PSUs) are to be installed at the customer
site (refer to Power Supplies).
•

AC PSU with fan airflow from I/O to PSU

•

AC PSU with fan airflow from PSU to I/O

•

DC PSU with fan airflow from I/O to PSU

•

DC PSU with fan airflow from PSU to I/O

All fans and PSUs in a configuration must be in the same airflow direction.
Should for some reason a mixed airflow configuration happen, the software is
designed to notify you of the invalid configuration.
Figure 1-1. S4820T Fan Modules
Fan Module 0

Grab Handles

6

Hardware Overview

Fan Module 1

Front Panel
Figure 1-2 shows the S4820T front panel.
Figure 1-2. S4820T Front Panel
10GBase-T Ports

USB 2.0 Port
QSFP+ Ports

The front panel includes:
•

48 fixed 10GBase-T and four fixed QSFP+ ports

•

One USB 2.0 port
NOTE: The light emitting diodes (LEDs) display for System is on the front panel.
The fan and power status indicators are on the back panel.

Hardware Overview

7

System Status
You can view S4820T status information in several ways, including LEDs and
boot menu options. You can also view status information through the
command line interface (CLI) show commands and with simple network
management protocol (SNMP). For more information about these options,
refer to the FTOS Command Line Reference Guide and FTOS Configuration
Guide for the S4820T System.
As shown in Figure 1-3, the S4820T includes LED displays on both the I/O and
PSU side of the chassis.
Figure 1-3. Port LEDs
1

System LED

3

2

5

4

6

7

6 7
1 - Locator LED (Blue)
2 - Stack LED (Blue/Green)
3 - Temp LED (Red)
4 - Diag LED (Green)
5 - FAN LED (Green/Red)
6 - Link LED (Green/Amber)
7 - Activity LED (Blinking
Green)

8

Hardware Overview

Table 1 lists the LED definitions for the S4820T system.
Table 1. System LED Displays
Feature
System LED

Detailed Description
• Solid blue –Normal
Operation

Comment
I/O side

• Blinking blue –Booting
• Solid red –Critical system
error
• Blinking red –Noncritical system error (fan
fail, power supply fail)
TEMP LED

• Off: Normal temperature PSU side
• Solid red –Overtemp
(Refer NOTE:)

DIAG LED

• Off –Normal operating

PSU side

• Solid green –System
Booting or Diagnostics
FAN LED

• Solid green –fan powered PSU side
and running at the
expected rpm
• Solid red –fan failed

STACK LED

• Solid blue –Switch in
stacking master mode

PSU side

• Solid green–Switch in
stacking slave mode
• Off – Switch in stand
alone mode
LOCATOR LED

• Blinking blue – locator
function is enabled

PSU side

• Solid blue – locator
function is disabled
NOTE: The system temperature threshold is 75°C. When one of the thermal
sensors exceeds this temperature, the TEMP LED turns RED.

Hardware Overview

9

Table 1-1. 10GBT Ethernet Port LEDs
Feature
Detailed Description
Link LED

• Off – No Link
• Solid green –Link on 10Gbps speed
• Solid Amber –Link on 100M or 1Gbps speeds

Activity LED

• Off – No Link
• Blinking green – Transmit/Receive is active

Table 1-2. QSFP+ Port LEDs
Feature
Detailed Description
Link LED

• Off – No Link
• Solid green –Link on 40Gbps speed
• Solid Amber –Link on other speeds

Activity LED

• Off – No Link
• Blinking green – Transmit/Receive is active

Table 1-3. OOB Ethernet Port LEDs
Feature
Detailed Description
Link LED

• Off – No Link
• Solid green –Link on 1Gbps speed
• Solid Amber –Link on 100M or 10M speeds

Activity LED

• Off – No Link
• Blinking green – Transmit/Receive is active

10

Hardware Overview

Installation
Unpacking the Switch
Package Contents
When unpacking each switch, make sure that the following items are
included:
•

One S4820T switch

•

One RJ-45 to DB-9 female cable

•

Two sets of rail kits (no tools required)

•

One PSU

•

One AC power cord (country/region specific)

•

Getting Started Guide

•

Safety and Regulatory Information

•

Warranty and Support Information

•

Software License Agreement

Unpacking Steps
NOTE: Before unpacking the switch, inspect the container and immediately
report any evidence of damage.
Step

Task

1

Place the container on a clean, flat surface and cut all straps securing the
container.

2

Open the container or remove the container top.

3

Carefully remove the switch from the container and place it on a secure and
clean surface.

4

Remove all packing material.

5

Inspect the product and accessories for damage.

Installation

11

Power Supplies
The S4820T supports two hot-swappable power supplies units (PSUs) and fans
that provide cooling for the system. The S4820T supports AC and DC power
supplies with two air-flow directions (I/O to PSU and PSU to I/O). Two PSUs
are required for full redundancy, but the system will operate with a single PSU.
NOTE: If you use a single PSU, you must install a blank plate in the other PSU
slot. Dell Force10 recommends using power supply 1 (PSU1) as the blank plate
slot.

The PSUs are field replaceable. When running with full redundancy (two power
supplies installed and running), you can remove and replace one PSU while the
other PSU is running without disrupting traffic.
The S4820T does not support mixing PSU types. You cannot replace an AC
PSU with a DC PSU and you cannot replace an AC-R PSU with a DC-R PSU.
WARNING: Electrostatic discharge (ESD) damage can occur if components
are mishandled. Always wear an ESD-preventive wrist or heel ground strap
when handling the S4820T and its components.
CAUTION: To prevent electrical shock, ensure the S4820T is grounded
properly. If you do not ground your equipment correctly, excessive emissions
may result. Use a qualified electrician to ensure the power cables meet your
local electrical requirements.

Figure 1-4. S4820T Power Supply
PS0

12

Installation

PS1

Install an AC or DC Power Supply
To install an AC or DC power supply, follow these steps:

NOTE: The PSU slides into the slot smoothly. Do not force a PSU into a slot as
this may damage the PSU or the S4820T chassis.
NOTE: Ensure that the PSU is correctly installed. When the PSU is correctly
installed, the power connector is on the left side of the PSU and the status LED is at
the top of the PSU
NOTE: If you use a single PSU, you must install a blank plate in the other PSU
slot. Dell Force10 recommends using power supply 1 (PSU1) as the blank plate
slot.

Step

Task

1

Remove the PSU slot cover from the S4820T (PSU side of switch), either of the
two PSU slots may be selected.

2

Remove the PSU from the electro-static bag.

3

• Insert the PSU into the switch PSU slot (PSU exposed PCB edge connector
should be inserted first).
• The PSU slot is keyed such that the PSU can only be fully inserted in one
orientation.
• When the PSU is installed correctly it should snap into place and be flush with
the back of the switch.

4

Plug in the appropriate cord (AC 3 prong or DC wiring) from the switch PSU to
the external power source (either AC wall outlet or DC rack bus bar).

5

If you have a redundant PSU (2nd PSU), repeat steps 1 through 5 above using
the 2nd PSU slot on the S4820T switch.
NOTE: The system powers up as soon as the cables are connected between the
power supply and the power source.

Installation

13

Rack Mounting the Switch
You may either place the switch on the rack shelf or mount the switch directly
into a 19" wide, EIA-310-E- compliant rack (four-post, two-post, or threaded
methods). The Dell ReadyRails™ system is provided for 1U front-rack, and
two-post installations. The ReadyRails system includes two separately
packaged rail assemblies and two rails that are shipped attached to the sides
of the switch.
WARNING: This is a condensed reference. Read the safety instructions in your
Safety, Environmental, and Regulatory information booklet before you begin.
NOTE: The illustrations in this document are not intended to represent a specific

switch.

Rack Mounting Safety Considerations

14

•

Rack loading—Overloading or uneven loading of racks may result in shelf
or rack failure, causing damage to the equipment and possible personal
injury. Stabilize racks in a permanent location before loading begins.
Mount the components beginning at the bottom of the rack, then work to
the top. Do not exceed your rack load rating.

•

Power considerations—Connect only to the power source specified on the
unit. When multiple electrical components are installed in a rack, ensure
that the total component power ratings do not exceed the circuit
capabilities. Overloaded power sources and extension cords present fire
and shock hazards.

•

Elevated ambient temperature—If installed in a closed rack assembly, the
operating temperature of the rack environment may be greater than the
room ambient temperature. Use care not to exceed the 40°C maximum
ambient temperature of the switch.

•

Reduced air flow—Install the equipment in the rack so that the amount of
airflow required for safe operation of the equipment is not compromised.

•

Reliable earthing—Maintain reliable earthing of rack-mounted
equipment. Pay particular attention to the supply connections other than
the direct connections to the branch circuit, for example: use of power
strips.

•

Do not mount the equipment with the rear panel facing in the downward
position.
Installation

Installing the Dell ReadyRails System
The ReadyRails rack mounting system is provided to easily configure your
rack for installation of your switch. The ReadyRails system can be installed
using the 1U tool-less method or one of three possible 1U tooled methods
(two-post flush mount, two-post center mount, or four-post threaded).
1U Tool-less Configuration (Four-post Square Hole or Unthreaded Round
Hole):
1 With the ReadyRails flange ears facing outward, place one rail between the
left and right vertical posts. Align and seat the rear flange rail pegs in the
rear vertical post flange. In Figure 1-5, item 1 and its extractions show how
the pegs appear in both the square and unthreaded round holes.
Figure 1-5. 1U Tool-less Configuration

2 Align and seat the front flange pegs in the holes on the front side of the
vertical post. Refer to Figure 1-5, item 2.
3 Repeat this procedure for the second rail.
4 To remove each rail, pull on the latch release button on each flange ear and
unseat each rail. Refer to Figure 1-5, item 3.

Installation

15

Two-post Flush-mount Configuration:

1 For this configuration, you must remove the castings from the front side of
each ReadyRails assembly. Refer to Figure 1-6, item 1. Use a Torx driver to
remove the two screws from each front flange ear (on the switch side of the
rail) and remove each casting. Retain the castings for future rack
requirements. It is not necessary to remove the rear flange castings.
Figure 1-6. Two-post Flush-mount Configuration

2 Attach one rail to the front post flange with two user-supplied screws.
Refer to Figure 1-6, item 2.
3 Slide the plunger bracket forward against the vertical post and secure the
plunger bracket to the post flange with two user-supplied screws. Refer
to Figure 1-6, item 3.

16

Installation

4 Repeat this procedure for the second rail.
Two-post Center-mount Configuration:

1 Slide the plunger bracket rearward until it clicks into place and secure the
bracket to the front post flange with two user-supplied screws. Refer
to Figure 1-7, item 1.
Figure 1-7. Two-post Center-mount Configuration

2 Slide the back bracket towards the post and secure it to the post flange
with two user-supplied screws. Refer to Figure 1-7, item 2.
3 Repeat this procedure for the second rail.

Installation

17

Four-post Threaded Configuration:
1 For this configuration, you must remove the flange ear castings from each
end of the ReadyRails assemblies. Use a Torx driver to remove the two
screws from each flange ear and remove each casting. Refer to Figure 1-8,
item 1. Retain the castings for future rack requirements.
2 For each rail, attach the front and rear flanges to the post flanges with two
user-supplied screws at each end. Refer to Figure 1-8, item 2.
Figure 1-8. Four-post Threaded Configuration

18

Installation

Installing the Switch
You can mount the switch in the 1U front-rack or 1U two-post (flush and
center) configurations. The following is an example of a 1U front-rack
configuration. For the 1U two-post (flush and center) configurations, you can
slide the switch into the rails in the same manner as the four-post
configurations.
1U Front-rack Installation

You must configure the rails that are attached to the switch.
1 Attach the switch rails (inner chassis members) to the S4820T switch.
Figure 1-9, item 1 shows the detail for the front standoff with the locking
tab.
Figure 1-9. Attaching the Switch Rails

Installation

19

2 After both switch rails are installed, line them up on the previously
mounted Ready-Rails and slide the switch in until it is flush with front of
rack. About three inches prior to full insertion, the rail locking feature
engages to keep the switch from inadvertently sliding out of the rack and
falling.

20

Installation

Technical Specifications
Operate the product at an ambient temperature not higher than 40°C.
Lithium Battery Caution: There is a danger of explosion if the battery is
incorrectly replaced.

Replace only with same or equivalent type. Dispose of the batteries according
to the manufacturer's instructions.

Chassis Physical Design
Parameter

Specifications

Height

1.71 inches (43.5 mm)

Width

17.09 inches (434 mm)

Depth

18.11 inches (460 mm)

Environmental Parameters
Parameter

Specifications

Operating temperature

32° to 104°F (0° to 40°C)

Operating humidity

10 to 85% (RH), non-condensing

Storage temperature

–40° to 158°F (–40° to 70°C)

Storage humidity

5 to 95% (RH), non-condensing

Maximum thermal output

419.7 BTU/hr

Technical Specifications

21

Power Requirements
Parameter

Specifications

Power supply

100–240 VAC 50/60 Hz

Maximum current draw per system

4 A @ 398.02watts/100vac
2 A @ 398.02watts/200vac

Maximum power consumption

398.02 Watts

Reliability

MTBF 355,178 hours

NOTE: The table below represents the DC PSU’s capabilities and does not
represent the S4820T operation.

DC Input Specification
The power supply operates within all specified limits over the following input
voltage range.

min/max input voltage range

−40.5V /−48V/ −60V

input power at full load

−40.5V/970W −48V/930W
−60V/950W (without fan)
−40.5V/980W −48V/940W
−60V/960W (with fan)

input current at full load

−40.5V/23.8A −48V/19.0A
−60V/15.6A (without fan)
−40.5V/24A −48V/19.2A
−60V/16.0A (with fan)

Start up VDC

39.0+/−1.5V

Start off VDC

37.5+/−1.5V

22

Technical Specifications

IEEE Standards
The S4820T switch complies with the following IEEE standards:
•802.1AB LLDP
•802.1ag Connectivity fault Management
•802.1D Bridging, STP
•802.1p L2 Prioritization
•802.1Q VLAN Tagging, Double VLAN Tagging, GVRP
•802.1s MSTP
•802.1w RSTP
•802.3ab Gigabit Ethernet (1000BASE-T)
•802.3ac Frame Extensions for VLAN Tagging
•802.3ad Link Aggregation with LACP
•802.3ae 10 Gigabit Ethernet (10GBASE-X)
•802.3ba 40 Gigabit Ethernet (40GBase-SR4, 40GBase-CR4) on optical ports
•802.3u Fast Ethernet (100BASE-TX)
•802.3x Flow Control
•802.3z Gigabit Ethernet (1000BASE-X)

Technical Specifications

23

24

Technical Specifications

2
Performing the Initial
Configuration
Navigating CLI Modes
The FTOS prompt changes to indicate the CLI mode. You must move linearly
through the command modes, with the exception of the end command which
takes you directly to EXEC Privilege mode and the exit command which moves
you up one command mode level.

Console Access
NOTE: Before starting this procedure, be sure you have a terminal emulation
program already installed on your PC.

The RS-232/RJ-45 console port is labeled on the upper right-hand side of the
S4820T system as you face the Input/Output (I/O) side of the chassis
(Figure 2-1).
Figure 2-1. RS-232/RJ-45 Console Port
RJ-45 Console Port

Performing the Initial Configuration

25

To set up the RS-232/RJ-45 console port, follow these steps:
Step

Task

1

Install an RJ-45 copper cable into the console port. Use a rollover cable to
connect the S4820T console port to a terminal server.

2

Connect the other end of the cable to the DTE terminal server.

3

Set the default terminal settings as follows:
• 9600 baud rate
• No parity
• 8 data bits
• 1 stop bit
• No flow control

Accessing the RJ-45 Console Port with a DB-9 Adapter

If the DTE has a DB-9 interface, you can connect to the console using an RJ-45
to DB-9 adapter along with the RJ-45 rollover cable. Table 2-1 lists the pin
assignments.
Table 2-1. Pin Assignments Between the Console and a DTE Terminal Server
Console Port

RJ-45 to RJ-45 Rollover Cable

RJ-45 to DB-9
Adapter

Terminal Server
Device

Signal

RJ-45 Pinout

RJ-45 Pinout

DB-9 Pin

Signal

RTS

1

8

8

CTS

NC

2

7

6

DSR

TxD

3

6

2

RxD

GND

4

5

5

GND

GND

5

4

5

GND

RxD

6

3

3

TxD

NC

7

2

4

DTR

CTS

8

1

7

RTS

26

Performing the Initial Configuration

Default Configuration
A version of FTOS is pre-loaded onto the S4820T system; however, the system is not
configured when you power up for the first time (except for the default host name, which
is FTOS). You must configure the system using the CLI.

Configure Layer 2 (Data Link) Mode
Use the switchport command in INTERFACE mode to enable Layer 2 data
transmissions through an individual interface. You cannot configure switching
or Layer 2 protocols such as Spanning Tree Protocol (STP) on an interface
unless the interface has been set to Layer 2 mode.
To configure Layer 2 mode, follow these steps:
Step Task

Command Syntax

Command Mode

1

Enable the interface.

no shutdown

INTERFACE

2

Place the interface in
Layer 2 (switching)
mode.

switchport

INTERFACE

To view the interfaces in Layer 2 mode, use the show interfaces switchport
command in EXEC mode.

Configure a Host Name
The host name appears in the prompt. The default host name is FTOS. Host
names must start with a letter, end with a letter or digit, and must have
characters, letters, digits, and hyphens in the string.
To configure a host name, follow this step:
Task

Command Syntax

Command Mode

Create a new host name.

hostname name

CONFIGURATION

Performing the Initial Configuration

27

Access the System Remotely
You can configure the S4820T system to be accessed remotely by Telnet. The
system has a dedicated management port and a management routing table that is
separate from the IP routing table.
To access the system remotely, follow these steps:
Step

Task

1

Configure an IP address for the management port (Configure the Management
Port IP Address).

2

Configure a management route with a default gateway (Configure the
Management Route).

3

Configure a username and password (Configure the Username and Password).

Configure the Management Port IP Address
In order to access the system remotely, assign IP addresses to the management
ports.
To assign IP addresses to the management ports, follow these steps:
Step Task

28

Command Syntax

Command Mode

1

Enter INTERFACE
mode for the
Management port.

interface ManagementEthernet
slot/port

CONFIGURATION

2

Assign an IP address
to the interface.

ip address ip-address/mask

INTERFACE

3

Enable the interface.

no shutdown

INTERFACE

Performing the Initial Configuration

Configure the Management Route
Define a path from the S4820T to the network from which you are accessing the
S4820T remotely. Management routes are separate from IP routes and are used
to manage the S4820T through the management port.
To configure a management route, follow this step:
Task

Command Syntax

Configure a
management route ip-address/mask
management route to gateway
the network from
which you are
accessing the system.

Command Mode
CONFIGURATION

Configure the Username and Password
To access the system remotely, configure a system username and password.
To configure a username and password, follow this step:
Task

Command Syntax

Configure a username username username [encryption-type]
and password to
password
access the system
remotely.

Command Mode
CONFIGURATION

Configure the Enable Password
Access EXEC Privilege mode using the enable command. EXEC Privilege
mode is unrestricted by default. As a basic security measure, configure a
password. There are two types of enable passwords:
•

enable password—stores the password in the running/startup configuration
using a data encryption standard (DES)-encryption method.

•

enable secret—stores the running/startup configuration using a stronger,
MD5-encryption method.

Dell Force10 recommends using the enable secret password.

Performing the Initial Configuration

29

To configure the enable secret password, follow this step:
Task

Command Syntax

Command Mode

Create a password to
access EXEC
Privilege mode.

enable [password | secret] [level level]
[encryption-type] password

CONFIGURATION

Create a Port-based VLAN
The Default VLAN (VLAN 1) is part of the system startup configuration and
does not require configuration. To configure a port-based VLAN, you must
create the VLAN and then add physical interfaces or port channel (LAG)
interfaces to the VLAN.
To create a port-based VLAN, follow this step:
Task

Command Syntax

Configure a port-based VLAN (if the interface vlan vlan-id
vlan-id is different from the Default
VLAN ID) and enter INTERFACE
VLAN mode. After you create a
VLAN, you must assign interfaces in
Layer 2 mode to the VLAN to activate
the VLAN.

Command Mode
CONFIGURATION

To view the configured VLANs, use the show vlan command in EXEC
Privilege mode.

Assign Interfaces to a VLAN
You can only assign interfaces in Layer 2 mode to a VLAN using the tagged and
untagged commands. To place an interface in Layer 2 mode, use the switchport
command.
You can designate Layer 2 interfaces as tagged or untagged. When you place an
interface in Layer 2 mode using the switchport command, the interface is
automatically designated untagged and placed in the Default VLAN.

30

Performing the Initial Configuration

To view which interfaces are tagged or untagged and to view which VLAN the
interfaces belong, use the show vlan command. To view just the interfaces that
are in Layer 2 mode, use the show interfaces switchport command in EXEC
Privilege mode or EXEC mode.
To tag frames leaving an interface in Layer 2 mode, you must assign that
interface to a port-based VLAN to tag it with that VLAN ID.
To tag interfaces, follow these steps:
Step Task

Command Syntax

Command Mode

1

Access the
interface vlan vlan-id
INTERFACE VLAN
mode of the VLAN to
which you want to
assign the interface.

CONFIGURATION

2

Enable an interface to tagged interface
include the IEEE
802.1Q tag header.

INTERFACE

Use the untagged command to move untagged interfaces from the Default
VLAN to another VLAN:
To move untagged interfaces, follow these steps:
Step Task

Command Syntax

Command Mode

1

Access the
interface vlan vlan-id
INTERFACE VLAN
mode of the VLAN to
which you want to
assign the interface.

CONFIGURATION

2

Configure an interface untagged interface
as untagged. This
command is available
only in VLAN
interfaces.

INTERFACE

Performing the Initial Configuration

31

Assign an IP Address to a VLAN
VLANs are a Layer 2 feature. For two physical interfaces on different VLANs
to communicate, you must assign an IP address to the VLANs to route traffic
between the two interfaces. The shutdown command in INTERFACE mode
does not affect Layer 2 traffic on the interface.
NOTE: You cannot assign an IP address to the Default VLAN, which, by default,
is VLAN 1. To assign another VLAN ID to the Default VLAN, use the default
vlan-id vlan-id command.

To assign an IP address to a VLAN, follow this step:
Task

Command Syntax

Configure an IP address ip address ip-address mask
and mask on the interface. [secondary]

Command Mode
INTERFACE

Connecting the S4820T to the Network
After you have completed the hardware installation and software configuration
for the S4820T system, you can connect to your company network by following
your company’s cabling requirements.

32

Performing the Initial Configuration

Printed in the U.S.A.

w w w. d e l l . c om | s u p p o r t . d e l l . c om



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : No
Language                        : en
Format                          : application/pdf
Creator                         : Dell Inc.
Title                           : Getting Started Guide for the S4820T System
Subject                         : Setup Guide
Description                     : Setup Guide
Producer                        : Acrobat Distiller 9.5.2 (Windows); modified using iTextSharp 5.1.3 (c) 1T3XT BVBA
Keywords                        : Servers, Storage and Networking#Force 10#force10 s4820#force10-s4820#Setup Guide#GSG# Getting Started# S4820T
Create Date                     : 2012:09:06 13:49:17Z
Creator Tool                    : FrameMaker 10.0.1
Modify Date                     : 2013:06:25 18:02:56-05:00
Page Mode                       : UseOutlines
Page Count                      : 39
Author                          : Dell Inc.
Productcode                     : force10-s4820
Typecode                        : sg
Typedescription                 : Setup Guide
Languagecodes                   : en-us
Publishdate                     : 2013-06-25 00:00:00
Expirydate                      : 9999-09-09 00:00:00
Manualurl                       : http://ftp.dell.com/manuals/all-products/esuprt_ser_stor_net/esuprt_force10/force10-s4820_Setup Guide_en-us.pdf
Readytocopy                     : false
Isdeleted                       : False
Businesskeywords                : GSG# Getting Started# S4820T
Futureproductindication         : No
Categorypathforfutureproducts   : 
Filesize                        : 536
Creationdate                    : D:20120906134917Z
Moddate                         : D:20130625130924-05'00'
EXIF Metadata provided by EXIF.tools

Navigation menu