Integrated Dell™ Remote Access
Controller 6 (iDRAC6) Enterprise
for Blade Servers
Version 2.0

User Guide

w w w. d e l l . c o m | s u p p o r t . d e l l . c o m

Notes and Cautions
NOTE: A NOTE indicates important information that helps you make better use of
your computer.
CAUTION: A CAUTION indicates potential damage to hardware or loss of data if
instructions are not followed.

___________________
Information in this document is subject to change without notice.
© 2009 Dell Inc. All rights reserved.
Reproduction of these materials in any manner whatsoever without the written permission of Dell Inc.
is strictly forbidden.
Trademarks used in this text: Dell, the DELL logo, Dell OpenManage, and PowerEdge, are trademarks
of Dell Inc.; Microsoft, Windows, Windows Server, MS-DOS, Windows Vista, ActiveX and Active
Directory are either trademarks or registered trademarks of Microsoft Corporation in the United States
and/or other countries; Red Hat and Linux are registered trademarks of Red Hat, Inc.; Novell and SUSE
are registered trademarks of Novell Corporation. Intel is a registered trademark of Intel Corporation;
UNIX is a registered trademark of The Open Group in the United States and other countries.
Copyright 1998-2006 The OpenLDAP Foundation. All rights reserved. Redistribution and use in source
and binary forms, with or without modification, are permitted only as authorized by the OpenLDAP Public
License. A copy of this license is available in the file LICENSE in the top-level directory of the distribution
or, alternatively, at www.OpenLDAP.org/license.html. OpenLDAP is a registered trademark of the
OpenLDAP Foundation. Individual files and/or contributed packages may be copyrighted by other parties
and subject to additional restrictions. This work is derived from the University of Michigan LDAP v3.3
distribution. This work also contains materials derived from public sources. Information about OpenLDAP
can be obtained at www.openldap.org/. Portions Copyright 1998-2004 Kurt D. Zeilenga. Portions
Copyright 1998-2004 Net Boolean Incorporated. Portions Copyright 2001-2004 IBM Corporation.
All rights reserved. Redistribution and use in source and binary forms, with or without modification,
are permitted only as authorized by the OpenLDAP Public License. Portions Copyright 1999-2003
Howard Y.H. Chu. Portions Copyright 1999-2003 Symas Corporation. Portions Copyright 1998-2003
Hallvard B. Furuseth. All rights reserved. Redistribution and use in source and binary forms, with or
without modification, are permitted provided that this notice is preserved. The names of the copyright
holders may not be used to endorse or promote products derived from this software without their specific
prior written permission. This software is provided "as is'' without express or implied warranty. Portions
Copyright (c) 1992-1996 Regents of the University of Michigan. All rights reserved. Redistribution and
use in source and binary forms are permitted provided that this notice is preserved and that due credit is
given to the University of Michigan at Ann Arbor. The name of the University may not be used to endorse
or promote products derived from this software without specific prior written permission. This software
is provided "as is'' without express or implied warranty. Other trademarks and trade names may be used
in this document to refer to either the entities claiming the marks and names or their products. Dell Inc.
disclaims any proprietary interest in trademarks and trade names other than its own.
March 2009

Rev. A00

Contents

1

iDRAC6 Enterprise Overview .

. . . . . . . . .

27

. . . . . . . . . . . . .

28

. . . . . . . . . . . . . . .

29

iDRAC6 Management Features
iDRAC6 Security Features .

iDRAC6 Firmware Improvements
Supported Platforms

. . . . . . . . . . . .

30

. . . . . . . . . . . . . . . . . .

30

Supported Operating Systems .
Supported Web Browsers .

. . . . . . . . . . . . .

30

. . . . . . . . . . . . . . .

31

Supported Remote Access Connections
iDRAC6 Ports

. . . . . . . .

32

. . . . . . . . . . . . . . . . . . . . . .

33

Other Documents You May Need

2

. . . . . . . . . . . .

Configuring iDRAC6 Enterprise
Before You Begin

34

. . . . . . . .

37

. . . . . . . . . . . . . . . . . . . .

37

. . . . . . . . . . .

38

. . . . . . . . . . . . . . . . . . .

41

Interfaces for Configuring iDRAC6
Configuration Tasks

. . . . . . . .

41

. . . . . . . . . . .

41

. . . . . . . . . . . . . .

42

Configure the Management Station
Configure iDRAC6 Networking
Configure iDRAC6 Users

Configure Active Directory .

. . . . . . . . . . . .

Configure IP Filtering and IP Blocking

. . . . . . .

Contents

42
42

3

Configure Platform Events

. . . . . . . . . . . . .

Enabling or Disabling Local Configuration
Access . . . . . . . . . . . . . . . . . .
Configure iDRAC6 Services

. . . . .

43

. . . . . . . . . . . .

43

. . . . . .

44

. . . . . . . . . . . . . .

44

Configure Secure Sockets Layer (SSL)
Configure Virtual Media

Configure a VFlash Media Card

. . . . . . . . . .

Install the Managed Server Software

. . . . . . .

Configure the Managed Server for the
Last Crash Screen Feature . . . . . . .

44
44

Configuring Networking Using the CMC
Web Interface . . . . . . . . . . . . . .

. . . . . . . .

45

Launching the iDRAC6 Web-based
Interface From the CMC . . . . . .

. . . . . . . .

45

Configuring Networking for iDRAC6

. . . . . . . .

47

. . . . . . . . .

48

. . . . . . . . . . . . . . .

48

Updating iDRAC6 Firmware

Downloading the Firmware or
Update Package . . . . . . .

. . . . . . . . . . .

Executing the Firmware Update

. . . . . . . . . .

Using the DOS Update Utility

49

. . . . . . . . .

51
52

. . . . . . . . . . .

53

. . . . . . . . . . . .

56

Verifying the Digital Signature
Clear Your Browser’s Cache

49

. . . . . . . . . . . .

Using the iDRAC6 Web Interface .

Updating the USC Repair Package

Contents

44

. . . . . .

Viewing FlexAddress Mezzanine Card
Fabric Connections . . . . . . . . . .

4

43

. . . . . . . . . . .

57

Configuring iDRAC6 For Use With IT Assistant .
Using the iDRAC6 Configuration Utility to
Enable Discovery and Monitoring . . . .

3

. . . .

57

. . . . .

58

Using the iDRAC6 Web Interface to
Enable Discovery and Monitoring .

. . . . . . . .

58

Using IT Assistant to View iDRAC6
Status and Events . . . . . . . . .

. . . . . . . .

60

. . . . . . . . .

61

. . . . . . . . . . .

61

Configuring the Management
Station . . . . . . . . . . . . . . . . . .
Management Station Set Up Steps

Management Station Network Requirements

. . . . .

61

. . . . . . . .

62

. . . . . . . . . . . .

62

Configuring a Supported Web Browser
Opening Your Web Browser

Configuring Your Web Browser to Connect
to the Web Interface . . . . . . . . . . . .
Adding iDRAC6 to the List of
Trusted Domains . . . . . .

. . . .

62

. . . . . . . . . . . .

65

Viewing Localized Versions of the
Web Interface . . . . . . . . . .
Setting the Locale in Linux

. . . . . . . . .

65

. . . . . . . . . . . . .

67

. . . . .

68

. . . . .

69

. . . . . . . . . . . .

70

. . . . . . . . . . . . . . . . .

70

Disabling the Whitelist Feature in Firefox
Installing a Java Runtime Environment (JRE)
Installing Telnet or SSH Clients .
Telnet with iDRAC6

Configuring the Backspace Key
For Telnet Sessions . . . . . .
SSH With iDRAC6
Installing a TFTP Server

. . . . . . . . . .

70

. . . . . . . . . . . . . . . . .

71

. . . . . . . . . . . . . . . . .

72

Installing Dell OpenManage IT Assistant

. . . . . . .

Contents

73

5

4

Configuring the Managed Server

. . . . . .

Installing the Software on the Managed Server

. . . .

75

. . . . . .

76

. . . . . . . . . . .

77

Configuring the Managed Server to Capture
the Last Crash Screen . . . . . . . . . . . .
Disabling the Windows Automatic
Reboot Option . . . . . . . . . . .

5

Configuring iDRAC6 Enterprise
Using the Web Interface . . . . .

. . . . . . . .

79

. . . . . . . . . . . . . .

80

Logging In

. . . . . . . . . . . . . . . . . . . . .

80

Logging Out

. . . . . . . . . . . . . . . . . . . . .

81

Accessing the Web Interface

Using Multiple Browser Tabs and
Windows . . . . . . . . . . . . .
Configuring the iDRAC6 NIC .

. . . . . . . . .

81

. . . . . . . . . . . . . .

82

Configuring the Network and
IPMI LAN Settings . . . . . .

. . . . . . . . . . .

Configuring Platform Events .

85

. . . . . . . . . . . . . .

87

Configuring Platform Event Filters (PEF)

. . . . . .

88

Configuring Platform Event Traps (PET)

. . . . . .

88

. . . . . . . . . . . . .

89

. . . . . . . . . . . . . . .

90

Configuring E-Mail Alerts
Configuring IPMI Over LAN

Adding and Configuring iDRAC6 Users

. . . . . . . . .

Securing iDRAC6 Communications Using SSL
and Digital Certificates . . . . . . . . . . . .
Secure Sockets Layer (SSL)

91

. . . . .

94

. . . . . . . . . . . .

95

Certificate Signing Request (CSR)

Contents

82

. . . . . .

Configuring IP Filtering and IP Blocking

6

75

. . . . . . . . .

95

Accessing the SSL Main Menu

Generating a New Certificate Signing
Request . . . . . . . . . . . . . . . .

. . . . . . .

97

. . . . . . . . . .

98

. . . . . . . . . . . .

99

Uploading a Server Certificate .
Viewing a Server Certificate

Configuring and Managing Active
Directory Certificates . . . . . . .

. . . . . .

101

. . . . . . . . . . .

104

. . . . . . . . . . . .

105

. . . . . . . . . . . . . .

105

Uploading an Active Directory
CA Certificate . . . . . . . .
Viewing an Active Directory
CA Certificate . . . . . . .

Enabling Local Configuration Access

. . . . . . .

105

Disabling Local Configuration Access

. . . . . . .

106

. . . . . . . . . . . . . .

106

. . . . . . . . . . . . . . .

109

Configuring iDRAC6 Services
Updating iDRAC6 Firmware

Updating iDRAC6 Firmware
Using the CMC . . . . . . .

6

100

. . . . . . . . . . .

Configuring Active Directory (Standard
Schema and Extended Schema) . . . .

Enabling or Disabling Local
Configuration Access . . . .

96

. . . . . . . . . .

111

. . . . . . . . . . . .

Using iDRAC6 With Microsoft
Active Directory . . . . . . . . . .
Prerequisites for Enabling Active
Directory Authentication for iDRAC6

. . . . . . . .

113

. . . . . . . . . .

Supported Active Directory Authentication
Mechanisms . . . . . . . . . . . . . . . . .

. . . . . .

Contents

114

114

7

Extended Schema Active Directory Overview
Extending the Active Directory Schema

. . . . .

115

. . . . . .

115

. . . . . . .

115

Overview of the iDRAC6 Schema
Extensions . . . . . . . . . . . .

. . . . . . . . .

116

Active Directory Object Overview

. . . . . . . . .

116

. . . . . . . . . .

118

Active Directory Schema Extensions

Accumulating Privileges Using
Extended Schema . . . . . . .

Configuring Extended Schema Active
Directory to Access iDRAC6 . . . . .

. . . . . . .

Installing the Dell Extension to the Active
Directory Users and Computers Snap-In
Adding iDRAC6 Users and Privileges to
Active Directory . . . . . . . . . . . .

. . . . .

125

. . . . . .

126

Configuring Active Directory With Extended
Schema Using the iDRAC6 Web-Based
Interface . . . . . . . . . . . . . . . . . . .
Configuring Active Directory With
Extended Schema Using RACADM

. . .

128

. . . . . . . .

130

Standard Schema Active Directory Overview
Single Domain Versus Multiple Domain
Scenarios . . . . . . . . . . . . . . . .

132

. . . . . .

134

. . . . . . .

134

Configuring Active Directory With
Standard Schema Using the iDRAC6
Web-Based Interface . . . . . . . .

. . . . . . .

134

. . . . . . . .

137

. . . . . . . . . . . . . . .

139

Testing Your Configurations

Enabling SSL on a Domain Controller .

. . . . . . . . .

Exporting the Domain Controller Root
CA Certificate to iDRAC6 . . . . . . .
Importing the iDRAC6 Firmware
SSL Certificate . . . . . . . . .
Contents

. . . . .

Configuring Standard Schema Active
Directory to Access iDRAC6 . . . . .

Configuring Active Directory With
Standard Schema Using RACADM .

8

119

140

. . . . . . .

140

. . . . . . . . . .

141

Using Active Directory to Log In to iDRAC6
Frequently Asked Questions

. . . . . .

142

. . . . . . . . . . . . . .

143

Active Directory Log In Issues

. . . . . .

146

. . . . . . . . .

146

. . . . . . . . . . . . . . . . . . .

147

Extended and Standard Schema .
Miscellaneous

7

Viewing the Configuration and
Health of the Managed Server
System Summary

149

. . . . . . . . . . . . . .

Integrated Dell Remote Access
Controller 6 - Enterprise . . . .

149
149

. . . . . . . . . .

150

. . . . . . . . . . . . . . . . . .

151

. . . . . . . . . . . . . . . . . . . . . .

151

. . . . . . . . . . . . . . . . . . . . . . .

151

. . . . . . . . . . . . . . . . . . . . . . . .

151

WWN/MAC Summary
System Health
iDRAC6

Batteries

. . . . . . . . . . . . . . . . . . . . . .

Voltages

152

. . . . . . . . . . . . . . . . . . .

152

. . . . . . . . . . . . . . . . . . . . . .

152

Temperatures

. . . . . . . . . . . . . . . . .

152

. . . . . . . . . . . . . . . . . . . . . . . . .

152

Power Monitoring
CPU

. . . . . . .

. . . . . . . . . . . . . . . . . . . .

Main System Enclosure

CMC

143

. . . . . . . . . . .

Active Directory Certificate Validation .

POST

. . . . . . . . . . . . . . . . . . . . . . . .

Misc Health

. . . . . . . . . . . . . . . . . . . .

Contents

153
153

9

8

Power Monitoring and Power
Management . . . . . . . . . . . . .
Configuring and Managing Power
Power Monitoring

155

. . . . . . . . . . . . . . . . . . . .

156

. . . . . . . . . . . . .

156

. . . . . . . . . . . . . . . . . . . .

158

Viewing Power Budget

. . . . . . . . . . . . . . .

159

. . . . . . . . . . . . . . . . . . . . . .

160

Executing Power Control
Operations on the Server .

9

. . . . . . . . . . . . .

Configuring and Using Serial
Over LAN . . . . . . . . . . . . . . . .
Enabling Serial Over LAN in the BIOS

Using Serial Over LAN (SOL)

. . . . . . . . . . .

164

. . . . . . . . . . . . . .

167

. . . . . . . . . .

167

. . . . . . . . . . . . . .

168

. . . . .

168

. . . . . .

168

. . . . . . . . . . . . . . .

169

Model for Redirecting SOL Over IPMItool
Disconnecting SOL session in SM-CLP
Using SOL over PuTTY

Using SOL over Telnet with Linux

. . . . . . . . .

Using SOL over IPMItool

170

. . . . . . .

170

. . . . . . . . . . . . . .

171

Using SOL over OpenSSH with Linux .
Opening SOL with SOL proxy

Contents

163
163

Model for Redirecting SOL Over
Telnet or SSH . . . . . . . . . .
Model for the SOL Proxy

. . . . . . . .

160

. . . . . . . . .

Configuring Serial Over LAN in the
iDRAC6 Web GUI . . . . . . . . . .

10

158

. . . . . . . . .

Viewing Power Budget Threshold
Power Control

155

. . . . . . . . . . .

Viewing Power Monitoring
Power Budgeting

. . . . . . . .

. . . . . . . . . . . .

171

Operating System Configuration

. . . . . . . .

177

. . . . . . . . . . . . .

182

Linux Enterprise Operating System
Windows 2003 Enterprise

10 Using GUI Console Redirection .
Overview

177

. . . . . . . . . . . .

. . . . . .

185
185

. . . . . . . . . . . . . . . . . . . . . . . .

Using Console Redirection

Supported Screen Resolutions and
Refresh Rates . . . . . . . . . . .

186

. . . . . . . .

Configuring the Management Station

186

. . . . . . .

Configuring Console Redirection and
Virtual Media in the iDRAC6 Web Interface

. . . .

187

. . . . .

189

. . . . . . . . . . . . . . . . .

191

Opening a Console Redirection Session .
Using the Video Viewer

185

. . . . . . . . . . . . . . .

Synchronizing the Mouse Pointers

. . . . . . .

195

. . . . . . . . . . . . . .

196

Disabling or Enabling Local Console .
Frequently Asked Questions

11 Configuring a VFlash Media Card
for Use With iDRAC6 . . . . . . . . . .
Installing a VFlash Media Card

. . . . .

201

. . . . . . . . . . . . .

Removing a VFlash Media Card

. . . . . . . . . .

Configuring the VFlash Media Card Using the
iDRAC6 Web Interface . . . . . . . . . . . .
Enabling or Disabling the VFlash
Media Card . . . . . . . . . . . .

201
202

. . . . .

202

. . . . . . . . .

202

. . . . . . . .

203

. . . . . . . . . . . . . . .

203

Formatting the VFlash Media Card .
Uploading Disk Image

194

. . . . . . . .

Viewing the VFlash Key Size

. . . . . . . . . . . .

Contents

203

11

Configuring the VFlash Media Card
Using RACADM . . . . . . . . . .

. . . . . . . . . . .

Enabling or Disabling the VFlash
Media Card . . . . . . . . . . .

. . . . . . . . . .

Formatting the VFlash Media Card

12 Configuring and Using
Virtual Media . . . . . . . .
Overview .

. . . . . . . . .

. . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . .

Windows-Based Management Station

205
205
206
207

. . . . . . . . . . . . . . .

208

. . . . . . . . . . . . . . . . .

209

Booting From Virtual Media

. . . . . . . . . . . .

211

Installing Operating Systems
Using Virtual Media . . . .

. . . . . . . . . . . .

212

Using Virtual Media When the Server’s
Operating System Is Running . . . . . .
Frequently Asked Questions

. . . . . .

212

. . . . . . . . . . . . . .

213

13 Using the Local RACADM
Command Line Interface .
Using the RACADM Command
RACADM Subcommands

. . . . . . . . . . .

219

. . . . . . . . . . . . .

219

. . . . . . . . . . . . . . . .

220

Using the RACADM Utility to Configure iDRAC6
Displaying Current iDRAC6 Settings

. . . .

221

. . . . . . . .

221

. . . . . .

222

. . . . . . . . . . . . . .

223

Managing iDRAC6 Users with RACADM
Adding an iDRAC6 User

Contents

204

. . . . . .

Configuring Virtual Media .

12

204

. . . . . . . .

Linux-Based Management Station .

Running Virtual Media .

204

Enabling an iDRAC6 User With Permissions .

. . .

224

. . . . . . . . . . . . .

224

. . . . . . . . . . . . . . .

225

Removing an iDRAC6 User
Testing E-mail Alerting

Testing the iDRAC6 SNMP
Trap Alert Feature . . . .

225

. . . . . . . . . . . . .

Configuring iDRAC6 Network Properties

. . . . .

225

. . . . . . . . . . . .

227

Configuring PEF

. . . . . . . . . . . . . . . . . .

229

Configuring PET

. . . . . . . . . . . . . . . . . .

229

Configuring IPMI Over LAN

Configuring IP Filtering (IP Range) .

. . . . . . . .

231

Configuring IP Filtering .

. . . . . . . . . . . . . .

232

Configuring IP Blocking

. . . . . . . . . . . . . .

234

Configuring iDRAC6 Telnet and
SSH Services Using Local RACADM .
Using an iDRAC6 Configuration File

. . . . . . .

236

. . . . . . . . . .

236

Creating an iDRAC6 Configuration File .
Configuration File Syntax

. . . . . .

237

. . . . . . . . . . . . .

237

Modifying the iDRAC6 IP Address in a
Configuration File . . . . . . . . . . .

. . . .

240

. . . . . . . . . . . . . .

241

Loading the Configuration File Into iDRAC6
Configuring Multiple iDRACs

14 Using iDRAC6 Enterprise
SM-CLP Command Line Interface
System Management With SM-CLP .

243
243

. . . . . . . . . . . . . . . .

244

. . . . . . . . . . . . . . . . . . . .

244

Navigating the MAP Address Space
Targets

. . . .

. . . . . . . . . .

iDRAC6 SM-CLP Support
SM-CLP Features

239

. . . . . .

. . . . . . . . . .

247

. . . . . . . . . . . . . . . . . . . . . . .

248

Contents

13

Using the Show Verb

. . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . .

249

. . . . . . . . . . . . . . .

249

Using the -display Option .
Using the -level Option

. . . . . . . . . . . . . .

249

. . . . . . . . . . . . . . .

250

Using the -output Option
iDRAC6 SM-CLP Examples

. . . . . . . . . . . .

250

. . . . . . . . . . . . . . . . .

251

Server Power Management
SEL Management .

MAP Target Navigation

. . . . . . . . . . . . . .

Setting the iDRAC6 IP Address,
Subnet Mask, and Gateway Address

. . . . . . .

Updating iDRAC6 Firmware Using SM-CLP

15 Deploying Your Operating
System Using iVMCLI . . .
Before You Begin

. . . . . . . . . . . . . . . . . . . .

Network Requirements .

253
255

257
257

. . . . . . . . . . .

257
257

. . . . . . . . . . . . .

Creating an Image File for Linux Systems

258

. . . . .

258

. . . . . . . . . . . . .

258

. . . . . . . . . . . . . . . .

258

Creating an Image File for
Windows Systems . . . .
Preparing for Deployment

253

. . . . . . . . . . . . . .

Creating a Bootable Image File

Configuring the Remote Systems .
Deploying the Operating System

Contents

. . . .

. . . . . . . . . . .

Remote System Requirements

14

249

. . . . . . . . .

258

. . . . . . . . . . . .

259

Using the Virtual Media Command
Line Interface Utility . . . . . . .

260

. . . . . . . . . . . .

261

. . . . . . . . . . . . . .

262

. . . . . . . . . . . . . . . .

262

Installing the iVMCLI Utility
Command Line Options .
iVMCLI Parameters

. . . . . . . . . . .

iVMCLI Operating System Shell Options

16 Using the iDRAC6
Configuration Utility
Overview

265

. . . . .

. . . . . . . . . . . . . . .

267
267

. . . . . . . . . . . . . . . . . . . . . . . .

Starting the iDRAC6 Configuration Utility

. . . . . . .

268

. . . . . . . .

268

. . . . . . . . . . . . . . . . . . . .

269

Using the iDRAC6 Configuration Utility .
iDRAC6 LAN

IPMI Over LAN

LAN Parameters

272

. . . . . . . . . . . .
. . . . . . . . . .

272

. . . . . . . . . . . . . .

273

. . . . . . . . . . . . . . . . . .

273

System Services Configuration
LAN User Configuration
System Event Log Menu

274

. . . . . . . . . . . . . .

Exiting the iDRAC6 Configuration Utility

17 Recovering and Troubleshooting
the Managed Server . . . . . . . . . .
Safety First–For You and Your System
Trouble Indicators

270

. . . . . . . . . . . . . . . . . .

Virtual Media Configuration

Reset to Default

269

. . . . . . . . . . . . . . . . . . .

274

. . . . . .

. . . . .

275

. . . . . . . . .

275

. . . . . . . . . . . . . . . . . . . .

276

LED Indicators

. . . . . . . . . . . . . . . . . . .

Other Trouble Indicators

276

. . . . . . . . . . .

277

. . . . . . . . . . . . . .

277

Hardware Trouble Indicators

Contents

15

Problem Solving Tools .

. . . . . . . . . . . . . . . . .

Checking the System Health

. . . . . . . . . . . .
. . . . . . .

279
279

Viewing the Last System Crash Screen

. . . . . .

281

. . . . . . . .

282

. . . . . . . . . . . . . .

290

Checking the Server Status Screen
for Error Messages . . . . . . . . .
Viewing System Information

. . . . . . . . . . . .

Identifying the Managed Server in
the Chassis . . . . . . . . . . . . .
Using the Diagnostics Console .

. . . . . . . .

293
294

. . . . . .

Troubleshooting and Frequently Asked Questions

A RACADM Subcommand Overview

. . . . .

296

301
301

. . . . . . . . . . . . . . . . . . . . . . . . . .

302

getconfig

. . . . . . . . . . . . . . . . . . . . . . . . .

304

getssninfo

. . . . . . . . . . . . . . . . . . . . . . . .

306

getsysinfo

. . . . . . . . . . . . . . . . . . . . . . . .

307

getractime

. . . . . . . . . . . . . . . . . . . . . . . .

310

setniccfg

. . . . . . . . . . . . . . . . . . . . . . . . .

311

getniccfg

. . . . . . . . . . . . . . . . . . . . . . . . .

312

getsvctag .
racreset
Contents

. . .

295

. . . . . . . . . . . . . . . . . . . . . . . . . . .

config

16

291

. . . . . . . . . .

Managing Power on a Remote System

help

280

. . . .

Viewing the Most Recent Boot Sequences

Viewing the iDRAC6 Log

278

. . . . . . . . . . . . .

Checking the System Event Log (SEL)
Checking the Post Codes .

278

. . . . . . . . . . . . . . . . . . . . . . . .

313

. . . . . . . . . . . . . . . . . . . . . . . . .

313

racresetcfg

. . . . . . . . . . . . . . . . . . . . . . .

314

serveraction

. . . . . . . . . . . . . . . . . . . . . . .

315

getraclog

. . . . . . . . . . . . . . . . . . . . . . . .

316

clrraclog

. . . . . . . . . . . . . . . . . . . . . . . . .

317

getsel

. . . . . . . . . . . . . . . . . . . . . . . . . .

317

clrsel .

. . . . . . . . . . . . . . . . . . . . . . . . . .

319

gettracelog
sslcsrgen

. . . . . . . . . . . . . . . . . . . . . . .

319

. . . . . . . . . . . . . . . . . . . . . . . .

321

sslcertupload

. . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . .

323

. . . . . . . . . . . . . . . . . . . . . . .

324

. . . . . . . . . . . . . . . . . . . . . . . .

326

. . . . . . . . . . . . . . . . . . . . . . . . .

328

sslcertdownload
sslcertview
testemail .
testtrap .

322

vmdisconnect
clrasrscreen

. . . . . . . . . . . . . . . . . . . . . .

329

. . . . . . . . . . . . . . . . . . . . . . .

329

localconredirdisable

. . . . . . . . . . . . . . . . . .

329

vmkey

. . . . . . . . . . . . . . . . . . . . . . . . . .

330

version

. . . . . . . . . . . . . . . . . . . . . . . . . .

330

Contents

17

B iDRAC6 Enterprise Property
Database Group and
Object Definitions . . . . . . . .
Displayable Characters
idRacInfo .

. . . . . . . . .

. . . . . . . . . . . . . . . . .

331

. . . . . . . . . . . . . . . . . . . . . . . .

331

idRacProductInfo (Read Only)

. . . . . . . . . . .

idRacDescriptionInfo (Read Only)
idRacBuildInfo (Read Only) .

332

. . . . . . . . . . .

332
333

. . . . . . . . . . . . . .

333

. . . . . . . . . . . . . . .

333

. . . . . . . . . . . . . . . . . . . . . . .

334

idRacName (Read Only)
idRacType (Read Only)
cfgOobSnmp

cfgOobSnmpAgentCommunity
(Read/Write) . . . . . . . . .

. . . . . . . . . . .

cfgLanNetworking .

334

. . . . . .

334

. . . . . . . . . . . . . . . . . . .

335

cfgOobSnmpAgentEnable (Read/Write)

cfgDNSDomainNameFromDHCP
(Read/Write) . . . . . . . . . . .

. . . . . . . . .

335

. . . . . . . .

335

. . . . . . . . . .

336

cfgDNSDomainName (Read/Write)
cfgDNSRacName (Read/Write)

cfgDNSRegisterRac (Read/Write)

. . . . . . . . .
. . . . .

336
337

. . . . . . . . . . .

337

. . . . . . . . . . . .

338

cfgDNSServer1 (Read/Write)
cfgDNSServer2 (Read/Write)
cfgNicEnable (Read/Write) .

336

. . . . . . . . . . .

cfgDNSServersFromDHCP (Read/Write) .

cfgNicIpAddress (Read/Write)

. . . . . . . . . . .

338

cfgNicNetmask (Read/Write)

. . . . . . . . . . .

338

cfgNicGateway (Read/Write)

. . . . . . . . . . .

339

cfgNicUseDhcp (Read/Write)

. . . . . . . . . . .

339

cfgNicMacAddress (Read Only)

Contents

332

. . . . . . . . .

. . . . . . . . . . . .

idRacVersionInfo (Read Only)

18

331

. . . . . . . . . .

340

cfgUserAdmin

. . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . .

340

. . . . . . . . . .

341

cfgUserAdminIndex (Read Only) .
cfgUserAdminIpmiLanPrivilege
(Read/Write) . . . . . . . . . .

cfgUserAdminPrivilege (Read/Write)

. . . . . . .

342

. . . . . . .

343

. . . . . . . . . . . . . . .

343

cfgUserAdminPassword (Write Only)

. . . . . . . . . . . . . .

344

. . . . . . . . . . . . . . . . . . . . . .

344

cfgUserAdminSolEnable
cfgEmailAlert

cfgEmailAlertIndex (Read Only)

. . . . . . . . . .

cfgEmailAlertAddress

. . . . . . . . .

344
345

. . . . . . . . . . . . .

345

. . . . . . . . . . . . . . . .

345

cfgEmailAlertCustomMsg
cfgSessionManagement

344

. . . . . . . . . . . . . . .

cfgEmailAlertEnable (Read/Write)

cfgSsnMgtConsRedirMaxSessions
(Read/Write) . . . . . . . . . . . .

. . . . . . . .

cfgSsnMgtSshIdleTimeout (Read/Write)

346

. . .

346

. . . . .

346

cfgSsnMgtWebserverTimeout (Read/Write)

. . . .

347

. . . . . . . . . . . . . . . . . . . . . . . . .

348

cfgSsnMgtTelnetIdleTimeout (Read/Write)
cfgSerial

341

. . . . . .

cfgUserAdminUserName (Read/Write)
cfgUserAdminEnable .

340

cfgSerialSshEnable (Read/Write)

. . . . . . . . .
. . . . . . . .

348

. . . . . . . . . . . . . . . . . . . . .

348

cfgSerialTelnetEnable (Read/Write)
cfgRemoteHosts

cfgRhostsSmtpServerIpAddr (Read/Write)
cfgUserDomain

348

. . . .

349

. . . . . . . . . . . . . . . . . . . . .

349

cfgUserDomainIndex (Read Only)

. . . . . . . . .

cfgUserDomainName (Read/Write)

. . . . . . . .

Contents

349
349

19

cfgServerPower

. . . . . . . . . . . . . . . . . . . . .
. . . . . . . .

350

. . . . . . . . .

350

cfgServerPowerStatus (Read Only)
cfgServerPowerServerAllocation
(Read Only) . . . . . . . . . . . .

cfgServerPowerActualPowerConsumption
(Read Only) . . . . . . . . . . . . . . . . .

. . . .

350

. . . . .

351

. . . . . .

351

. . . . . . . .

351

cfgServerPowerPeakPowerConsumption
(Read Only) . . . . . . . . . . . . . . . .
cfgServerPowerPeakPowerTimestamp
(Read Only) . . . . . . . . . . . . . . .
cfgServerPowerConsumptionClear
(Write Only) . . . . . . . . . . . . .

cfgServerPowerCapWatts (Read Only)

. . . . . .

352

cfgServerPowerCapBtuhr (Read Only) .

. . . . . .

352

. . . . .

352

. . . . . . . . . . . . . . . . . . . . . .

353

cfgServerPowerCapPercent (Read Only)
cfgRacTuning

cfgRacTuneHttpPort (Read/Write)

. . . . . . . . .

353

cfgRacTuneHttpsPort (Read/Write)

. . . . . . . .

353

. . . . . . . . . . . .

354

cfgRacTuneIpRangeAddr .

. . . . . . . . . . . . .

354

cfgRacTuneIpRangeMask

. . . . . . . . . . . . .

354

. . . . . . . . . . . . . .

355

cfgRacTuneIpRangeEnable

cfgRacTuneIpBlkEnable

cfgRacTuneIpBlkFailCount

. . . . . . . . . . . . .
. . . . . . . . . . .

355

cfgRacTuneIpBlkPenaltyTime

. . . . . . . . . . .

356

. . . . . . . . .

356

. . . . .

356

cfgRacTuneTelnetPort (Read/Write)

. . . . . . . .

357

cfgRacTuneConRedirEncryptEnable
(Read/Write) . . . . . . . . . . . .

. . . . . . . .

357

cfgRacTuneConRedirEnable (Read/Write)

. . . . . .

357

. . . . . . . . . .

358

cfgRacTuneConRedirPort (Read/Write)
cfgRacTuneConRedirVideoPort
(Read/Write) . . . . . . . . . .

cfgRacTuneAsrEnable (Read/Write)

Contents

355

cfgRacTuneIpBlkFailWindow

cfgRacTuneSshPort (Read/Write)

20

350

. . . . . . . .

358

cfgRacTuneWebserverEnable
(Read/Write) . . . . . . . . .

. . . . . . . . . . .

358

cfgRacTuneLocalServerVideo
(Read/Write) . . . . . . . . .

. . . . . . . . . . .

359

cfgRacTuneLocalConfigDisable
(Read/Write) . . . . . . . . . .
ifcRacManagedNodeOs .

. . . . . . . . . .

359

. . . . . . . . . . . . . . . .

360

. . . . . . . .

360

. . . . . . . . .

360

. . . . . . . . . . . . . . . . . . . . .

360

ifcRacMnOsHostname (Read Only)
ifcRacMnOsOsName (Read Only)
cfgRacSecurity

cfgSecCsrCommonName (Read/Write)

. . . . . .

cfgSecCsrOrganizationName (Read/Write)

. . . . .

361
361

. . . . . . . .

362

cfgSecCsrLocalityName (Read/Write) .
cfgSecCsrCountryCode (Read/Write)
cfgSecCsrEmailAddr (Read/Write) .

. . . . . . .

362

. . . . . . . .

362

. . . . . . . . . .

363

. . . . . . . . . . . . . . . . . . . . . .

363

cfgSecCsrKeySize (Read/Write)
cfgRacVirtual

361

. . . . . .

cfgSecCsrOrganizationUnit (Read/Write)
cfgSecCsrStateName (Read/Write)

361

. . . .

cfgVirMediaAttached (Read/Write)

. . . . . . . .

363

cfgVirMediaBootOnce (Read/Write) .

. . . . . . .

364

cfgVirMediaKeyEnable (Read/Write)

. . . . . . .

364

. . . . . . . . .

365

. . . . . . . . . . . . . . . . . . .

365

cfgFloppyEmulation (Read/Write)
cfgActiveDirectory

. . . . . . . . . .

365

. . . . . . . . . . .

366

. . . . . . . . . . . . .

366

cfgADRacDomain (Read/Write)
cfgADRacName (Read/Write)
cfgADEnable (Read/Write)

cfgADAuthTimeout (Read/Write) .

. . . . . . . . .

366

cfgADDomainController1 (Read/Write)

. . . . . .

367

cfgADDomainController2 (Read/Write)

. . . . . .

367

cfgADDomainController3 (Read/Write)

. . . . . .

367

Contents

21

cfgADGlobalCatalog1 (Read/Write)

. . . . . . . .

368

cfgADGlobalCatalog2 (Read/Write)

. . . . . . . .

368

cfgADGlobalCatalog3 (Read/Write)

. . . . . . . .

368

. . . . . . . . . . . . . .

369

cfgADType (Read/Write)

. . . . .

369

. . . . . . . . . . . . . . . . . . .

369

cfgADCertValidationEnable (Read/Write)
cfgStandardSchema

cfgSSADRoleGroupIndex (Read Only)

. . . . . . .

cfgSSADRoleGroupName (Read/Write)

. . . . . .

370

. . . .

370

. . . . . . . . . . . . . . . . . . . . . . . .

371

cfgSSADRoleGroupPrivilege (Read/Write)

cfgIpmiSolEnable (Read/Write)

. . . . . . . . . .

cfgIpmiSolBaudRate (Read/Write)

. . . . . . . . .

cfgIpmiSolMinPrivilege (Read/Write)

. . . . . . .

373

. . . . . . . . . . . . . . . . . . . . . . . .

373

. . . . . . . . . .

cfgIpmiLanPrivLimit (Read/Write)

. . . . . . . . .

cfgIpmiEncryptionKey (Read/Write)

373
373

. . . . . . .

374

. . . . . . . .

374

cfgIpmiLanAlertEnable (Read/Write) .

. . . . .

374

. . . . . . . . . . . . . . . . . . . . . . . .

375

cfgIpmiPetCommunityName (Read/Write)

Contents

372
372

cfgIpmiLanEnable (Read/Write)

22

372

. . .

cfgIpmiSolSendThreshold (Read/Write)

cfgIpmiPef

371

. . . . . .

cfgIpmiSolAccumulateInterval (Read/Write)

cfgIpmiLan

370

. . . . .

cfgSSADRoleGroupDomain (Read/Write)

cfgIpmiSol

369

cfgIpmiPefName (Read Only)

. . . . . . . . . . .

375

cfgIpmiPefIndex (Read Only)

. . . . . . . . . . . .

375

cfgIpmiPefAction (Read/Write)

. . . . . . . . . .

376

cfgIpmiPefEnable (Read/Write)

. . . . . . . . . .

376

cfgIpmiPet

376

. . . . . . . . . . . . . . . . . . . . . . . .

cfgIpmiPetIndex (Read/Write)

. . . . .

377

. . . . . . .

377

cfgIpmiPetAlertDestIpAddr (Read/Write)
cfgIpmiPetAlertEnable (Read/Write) .

C iDRAC6 SM-CLP Property Database
/system1/sp1/account<1-16>
userid (Read Only)

376

. . . . . . . . . . .

. . .

379

. . . . . . . . . . . . . .

379

. . . . . . . . . . . . . . . . .

379

username (Read/Write)

. . . . . . . . . . . . . .

oemdell_ipmilanprivileges (Read/Write) .
password (Write Only)

380

. . . . . . . . . . . . . . .

380

. . . . . . . . . . . . .

381

. . . . . . . . . . . . . .

381

enabledstate (Read/Write)
solenabled (Read/Write)

. . . .

381

. . . . . . . . . . . . . . . .

383

oemdell_extendedprivileges (Read/Write)
/system1/sp1/enetport1/*

379

. . . . .

macaddress (Read Only)

. . . . . . . . . . . . . .
. . . . . .

383

. . . . . . . . .

383

. . . . . . . . . . . . . .

384

/system1/sp1/enetport1/lanendpt1/ipendpt1
oemdell_nicenable (Read/Write)
ipaddress (Read/Write)

subnetmask (Read/Write)

. . . . . . . . . . . . .

384

. . . . . . . . . .

384

. . . . . . . . . . . . . .

385

oemdell_usedhcp (Read/Write)
committed (Read/Write)

383

/system1/sp1/enetport1/lanendpt1/
ipendpt1/dnsendpt1 . . . . . . . .

. . . . . . . . . . .

oemdell_domainnamefromdhcp
(Read/Write) . . . . . . . . . .

. . . . . . . . . .

385

. . . . . .

386

. . . . . . .

386

. . . . . . . .

386

oemdell_dnsdomainname (Read/Write)
oemdell_dnsregisterrac (Read/Write)
oemdell_dnsracname (Read/Write)

385

oemdell_serversfromdhcp (Read/Write)

. . . . .

Contents

387

23

/system1/sp1/enetport1/lanendpt1/
ipendpt1/dnsendpt1/remotesap1 .

. . . . . . . . . . .
. . . . . . . . . .

387

. . . . . . . . . . .

388

dnsserveraddress (Read/Write)
/system1/sp1/enetport1/lanendpt1/
ipendpt1/dnsendpt1/remotesap2 .

. . . . . . . . . .

388

. . . . . . . . . . .

388

dnsserveraddress (Read/Write)
/system1/sp1/enetport1/lanendpt1/
ipendpt1/remotesap1 . . . . . . .

. . . . . . .

388

. . . . . . . . . . . . . . . .

388

defaultgatewayaddress (Read/Write)
/system1/sp1/group<1-5>

oemdell_groupname (Read/Write)

. . . . . . . . .

oemdell_groupdomain (Read/Write)

. . . . . . . .

. . . . . . . . . . .

390

. . . . . . . . . . . . .

390

oemdell_adracname (Read/Write)

. . . . . . . . .

391

. . . . . . .

391

. . . . . . . . . . .

392

oemdell_adrootdomain (Read/Write)
oemdell_timeout (Read/Write)

. . . . . . . .

392

. . . . . . . . . .

392

oemdell_schematype (Read/Write)
oemdell_adspecifyserverenable
(Read/Write) . . . . . . . . . .

. . . .

393

. . . . . .

393

. . . . . . . . . .

393

. . . . . . . . . . . .

393

oemdell_addomaincontroller (Read/Write)
oemdell_adglobalcatalog (Read/Write)
/system1/sp1/oemdell_racsecurity1
commonname (Read/Write)

391

. . . . . . . .

oemdell_adracdomain (Read/Write)

organizationname (Read/Write)

. . . . . . . . . .

394

. . . . . . . .

394

. . . . . . . . .

395

oemdell_localityname (Read/Write)
oemdell_statename (Read/Write)

394

. . . . . .

oemdell_organizationunit (Read/Write)

Contents

389
389

/system1/sp1/oemdell_adservice1
enabledstate (Read/Write)

389

. . . . . . .

oemdell_groupprivilege (Read/Write)

24

387

oemdell_countrycode (Read/Write)

. . . . . . . .

395

. . . . . . .

395

. . . . . . . . . . .

396

/system1/sp1/oemdell_ssl1

. . . . . . . . . . . . . . .

396

generate (Read/Write)

. . . . . . . . . . . . . . .

396

oemdell_emailaddress (Read/Write)
oemdell_keysize (Read/Write)

oemdell_status (Read Only)

. . . . . . . . . .

397

. . . . . . . . . . .

397

. . . . . . . . . . . . .

397

oemdell_certtype (Read / Write)
/system1/sp1/oemdell_vmservice1
enabledstate (Read/Write)

396

. . . . . . . . . . . .

oemdell_singleboot (Read/Write)

398

. . . . . . . . .

oemdell_floppyemulation (Read/Write)

398

. . . . . .
. . . . .

399

portnumber (Read/Write)

. . . . . . . . . . . . .

399

portnumber (Read/Write)

. . . . . . . . . . . . .

400

/system1/sp1/oemdell_vmservice1/tcpendpt1

oemdell_sslenabled (Read Only) .

D RACADM and SM-CLP
Equivalencies . . . . . . .

400

. . . . . . . . .

. . . . . . . . . . . . .

401

Glossary . . . . . . . . . . . . . . . . . . . . . . . . . . . . 413
Index

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

423

Contents

25

26

Contents

iDRAC6 Enterprise Overview
The Integrated Dell™ Remote Access Controller (iDRAC6) is a systems
management hardware and software solution that provides remote
management capabilities, crashed system recovery, and power control
functions for Dell PowerEdge™ systems.
iDRAC6 uses an integrated System-on-Chip microprocessor for the remote
monitor/control system, and co-exists on the system board with the managed
PowerEdge server. The server operating system is concerned with executing
applications; iDRAC6 is concerned with monitoring and managing the
server’s environment and state outside of the operating system.
You can configure iDRAC6 to send you an e-mail or Simple Network
Management Protocol (SNMP) trap alert for warnings or errors. To help you
diagnose the probable cause of a system crash, iDRAC6 can log event data
and capture an image of the screen when it detects that the system has
crashed.
Managed servers are installed in a Dell M1000e system enclosure (chassis)
with modular power supplies, cooling fans, and a chassis management
controller (CMC). The CMC monitors and manages all components
installed in the chassis. A redundant CMC can be added to provide hot
failover if the primary CMC fails. The chassis provides access to iDRAC6
devices through its LCD display, local console connections, and its Web
interface.
All network connections to iDRAC6 are through the CMC network interface
(CMC RJ45 connection port labelled "Gb"). The CMC routes traffic to the
iDRAC6 devices on its servers through a private, internal network. This
private management network is outside of the server’s data path and outside
of the operating system’s control—that is, out-of-band. The managed servers’
inband network interfaces are accessed through I/O modules (IOMs) installed
in the chassis.

iDRAC6 Enterprise Overview

27

The iDRAC6 network interface is disabled by default. It must be configured
before iDRAC6 is accessible. After iDRAC6 is enabled and configured on the
network, it can be accessed at its assigned IP address with the iDRAC6 Web
interface, telnet or SSH, and supported network management protocols,
such as Intelligent Platform Management Interface (IPMI).

iDRAC6 Management Features
iDRAC6 provides the following management features:

28

•

Dynamic Domain Name System (DDNS) registration

•

Remote system management and monitoring using a Web interface,
the local RACADM command line interface via console redirection,
and the SM-CLP command line over a telnet/SSH connection

•

Support for Microsoft Active Directory® authentication — Centralizes
iDRAC6 user IDs and passwords in Active Directory using the standard
schema or an extended schema

•

Console Redirection — Provides remote system keyboard, video,
and mouse functions

•

Virtual Media — Enables a managed server to access a local media drive on
the management station or ISO CD/DVD images on a network share

•

Monitoring — Provides access to system information and status of
components

•

Access to system logs — Provides access to the system event log,
the iDRAC6 log, and the last crash screen of the crashed or unresponsive
system that is independent of the operating system state

•

Dell OpenManage™ software integration — Enables you to launch the
iDRAC6 Web interface from Dell OpenManage Server Administrator
or IT Assistant

•

Boot capture — Provides up to three boot capture screens for later
debugging

•

iDRAC6 alert — Alerts you to potential managed node issues through an
e-mail message or SNMP trap

•

Remote power management — Provides remote power management
functions, such as shutdown and reset, from a management console

iDRAC6 Enterprise Overview

•

Single Sign-On from CMC Web interface — Once you log into CMC,
you can access any IDRAC6 in the chassis without having to log in again

•

One-To-Many Firmware Update — Enables automated update of more
than one iDRAC6 without operator intervention

•

Intelligent Platform Management Interface (IPMI) support

•

Secure Sockets Layer (SSL) encryption — Provides secure remote system
management through the Web interface

•

Password-level security management — Prevents unauthorized access to a
remote system

•

Role-based authority — Provides assignable permissions for different
systems management tasks

iDRAC6 Security Features
iDRAC6 provides the following security features:
•

User authentication through Microsoft Active Directory (optional) or
hardware-stored user IDs and passwords

•

Role-based authority, which enables an administrator to configure specific
privileges for each user

•

User ID and password configuration through the Web interface, SM-CLP,
and local RACADM

•

SM-CLP and Web interfaces, which support 128-bit and 40-bit encryption
(for countries where 128 bit is not acceptable), using the SSL 3.0 standard

•

Session time-out configuration (in seconds) through the Web interface or
SM-CLP

•

Configurable IP ports (where applicable)
NOTE: Telnet does not support SSL encryption.

•

Secure Shell (SSH), which uses an encrypted transport layer for higher
security

•

Login failure limits per IP address, with login blocking from the IP address
when the limit is exceeded

•

Limited IP address range for clients connecting to iDRAC6

iDRAC6 Enterprise Overview

29

iDRAC6 Firmware Improvements
In addition, important improvements have been made to the code:
•

Major improvements in Active Directory lookup performance

•

Improved responsiveness of TCP-IP networking stack

•

Improved health status interface between iDRAC6 and CMC

•

Security improvements using multiple third-party analysis tools

Supported Platforms
iDRAC6 supports the following PowerEdge systems in the Dell PowerEdge
M1000e system enclosure:
•

PowerEdge M610

•

PowerEdge M710

See the iDRAC6 Readme file located on the Dell Support website at
support.dell.com/manuals for the latest supported platforms.

Supported Operating Systems
Table 1-1 lists the operating systems that support iDRAC6.
See the Dell Systems Software Support Matrix located on the Dell Support
website at support.dell.com/manuals for the latest information.

30

iDRAC6 Enterprise Overview

Table 1-1.

Supported Operating Systems

Operating System
Family

Operating System

Microsoft®
Windows®

Microsoft Windows Server® 2003 R2 Standard and Enterprise
(32-bit x86) Editions with SP2
Microsoft Windows Server 2003 Web, Standard and Enterprise
(32-bit x86) Editions with SP2
Microsoft Windows Server 2003 Standard and Enterprise (x64)
Editions with SP2
Microsoft Windows Storage Server 2003 R2 Express, Workgroup,
Standard, and Enterprise x64 Editions
Microsoft Windows Server 2008 Web, Standard, and Enterprise
(32-bit x86) Editions
Microsoft Windows Server 2008 Web, Standard, Enterprise and
Datacenter (x64) Editions
MS HyperV 2008

NOTE: When installing Windows Server 2003 with Service Pack 1,
be aware of changes to DCOM security settings. For more
information, see article 903220 from the Microsoft Support website
at support.microsoft.com/kb/903220.
Enterprise Linux WS, ES, and AS (version 4) (x86 and x86_64)
Red Hat®
Enterprise Linux® Enterprise Linux 5 (x86 and x86_64)
SUSE® Linux

Enterprise Server 10 (Gold) (x86_64)

VMware

ESX 3.5 U4

Supported Web Browsers
Table 1-2 lists the Web browsers that are supported as iDRAC6 clients.
See the iDRAC6 Readme file and the Dell Systems Software Support Matrix
located on the Dell Support website at support.dell.com/manuals for the
latest information.
NOTE: Due to serious security flaws, support for SSL 2.0 has been discontinued.
For your browser to work properly, you must enable SSL 3.0.

iDRAC6 Enterprise Overview

31

Table 1-2.

Supported Web Browsers

Operating System

Supported Web Browser

Windows

Internet Explorer® 6.0 with Service Pack 2 (SP2) for Windows
XP and Windows 2003 R2 SP2 only
Internet Explorer 7.0 for Windows Vista®, Windows XP,
Windows 2003 R2 SP2, and Windows Server 2008 only
Mozilla Firefox 2.0/3.0 for Windows (Java vKVM/vMedia
console only)

Linux

Mozilla Firefox 2.0/3.0 on Red Hat Enterprise Linux 4 and 5
(32-bit or 64-bit) and SUSE Linux Enterprise Server 10 (32-bit
or 64-bit)

Supported Remote Access Connections
Table 1-3 lists the connection features.
Table 1-3.

Supported Remote Access Connections

Connection

Features

iDRAC6 NIC

• 10Mbps/100Mbs/1Gbps Ethernet via CMC Gb Ethernet port
• DHCP support
• SNMP traps and e-mail event notification
• Support for SM-CLP (telnet or SSH) command shell for
operations such as iDRAC6 configuration, system boot, reset,
power on, and shutdown commands
• Support for IPMI utilities, such as IPMItool and ipmish

32

iDRAC6 Enterprise Overview

iDRAC6 Ports
Table 1-4 lists the ports on which iDRAC6 listens for connections. Table 1-5
identifies the ports that iDRAC6 uses as a client. This information is required
when opening firewalls for remote access to an iDRAC6.
Table 1-4.

iDRAC6 Server Listening Ports

Port Number

Function

22*

Secure Shell (SSH)

23*

Telnet

80*

HTTP

443*

HTTPS

623

RMCP/RMCP+

3668*, 3669*

Virtual Media Service

3770*, 3771*

Virtual Media Secure Service

5900*

Console Redirection keyboard/mouse

5901*

Console Redirection video

* Configurable port

Table 1-5.

iDRAC6 Client Ports

Port Number

Function

25

SMTP

53

DNS

68

DHCP-assigned IP address

69

TFTP

162

SNMP trap

636

LDAPS

3269

LDAPS for global catalog (GC)

iDRAC6 Enterprise Overview

33

Other Documents You May Need
In addition to this User Guide, the following documents provide additional
information about the setup and operation of iDRAC6 in your system:
•

The iDRAC6 online help provides information about using the
Web interface.

•

The Dell Chassis Management Controller Firmware Version 2.0 User Guide
and the Dell Chassis Management Controller Firmware Version 2.0
Administrator Reference Guide provide information about using the
controller that manages all modules in the chassis containing your
PowerEdge server.

•

The Dell OpenManage IT Assistant User’s Guide provides information
about using IT Assistant.

•

The Dell OpenManage Server Administrator User’s Guide provides
information about installing and using Server Administrator.

•

The Dell Update Packages User’s Guide provides information about
obtaining and using Dell Update Packages as part of your system
update strategy.

•

The Dell Unified Server Configurator User’s Guide provides information on
installing and running the Unified Server Configurator.

The following system documents are also available to provide more
information about the system in which iDRAC6 is installed:

34

•

The safety instructions that came with your system provide important
safety and regulatory information. For additional regulatory information,
see the Regulatory Compliance home page at www.dell.com/
regulatory_compliance. Warranty information may be included within
this document or as a separate document.

•

The Getting Started Guide provides an overview of system features,
setting up your system, and technical specifications.

•

The Hardware Owner’s Manual provides information about system
features and describes how to troubleshoot the system and install or
replace system components.

•

Systems management software documentation describes the features,
requirements, installation, and basic operation of the software.

iDRAC6 Enterprise Overview

•

Operating system documentation describes how to install (if necessary),
configure, and use the operating system software.

•

Documentation for any components you purchased separately provides
information to configure and install these options.

•

Updates are sometimes included with the system to describe changes to
the system, software, and/or documentation.
NOTE: Always read the updates first because they often supersede
information in other documents.

•

Release notes or readme files may be included to provide last-minute
updates to the system or documentation or advanced technical reference
material intended for experienced users or technicians.

iDRAC6 Enterprise Overview

35

36

iDRAC6 Enterprise Overview

Configuring iDRAC6 Enterprise
This section provides information about how to establish access to iDRAC6
and to configure your management environment to use iDRAC6.

Before You Begin
Gather the following items prior to configuring iDRAC6:
•

Dell Chassis Management Controller Firmware User Guide

•

Dell Systems Management Tools and Documentation DVD

The Dell Systems Management Tools and Documentation DVD includes the
following components:
•

DVD root — Contains the Dell Systems Build and Update Utility,
which provides server setup and system installation information

•

SYSMGMT — Contains the systems management software products
including Dell OpenManage Server Administrator

•

DOCS — Contains documentation for systems management software
products, peripherals, and RAID controllers

•

SERVICE — Contains the tools you need to configure your system, and
delivers the latest diagnostics and Dell-optimized drivers for your system

For more information, see the Server Administrator User’s Guide,
the IT Assistant User’s Guide, and the Unified Server Configurator User Guide
available on the Dell Support website at support.dell.com\manuals.

Configuring iDRAC6 Enterprise

37

Interfaces for Configuring iDRAC6
You can configure iDRAC6 using the iDRAC6 Configuration Utility,
the iDRAC6 Web interface, the local RACADM CLI, or the SM-CLP CLI.
The local RACADM CLI is available after you have installed the operating
system and the Dell OpenManage software on the managed server. Table 2-1
describes these interfaces.
For greater security, access to iDRAC6 configuration through the iDRAC6
Configuration Utility or Local RACADM CLI can be disabled by means of a
RACADM command (see "RACADM Subcommand Overview") or from the
GUI (see "Enabling or Disabling Local Configuration Access").
NOTE: Using more than one configuration interface at the same time may generate
unexpected results.
Table 2-1. Configuration Interfaces
Interface

Description

iDRAC6 Configuration
Utility

Accessed at boot time, the iDRAC6
Configuration Utility is useful when installing
a new PowerEdge server. Use it for setting up
the network and basic security features and
for enabling other features.

iDRAC6 Web Interface

The iDRAC6 Web interface is a browser-based
management application that you can use to
interactively manage iDRAC6 and monitor the
managed server. It is the primary interface for
day-to-day tasks, such as monitoring system
health, viewing the system event log,
managing local iDRAC6 users, and launching
the CMC Web interface and console
redirection sessions.

CMC Web Interface

In addition to monitoring and managing the
chassis, the CMC Web interface can be used to
view the status of a managed server, configure
iDRAC6 network settings, and to start, stop,
or reset the managed server.

38

Configuring iDRAC6 Enterprise

Table 2-1.

Configuration Interfaces (continued)

Interface

Description

Chassis LCD Panel

The LCD panel on the chassis containing
iDRAC6 can be used to view the high-level
status of the servers in the chassis.
During initial configuration of the CMC,
the configuration wizard allows you to enable
DHCP configuration of iDRAC6 networking.

Local RACADM

The local RACADM command line interface
runs on the managed server. It is accessed from
either the iKVM or a console redirection
session initiated from the iDRAC6
Web interface. RACADM is installed on
the managed server when you install
Dell OpenManage Server Administrator.
RACADM commands provide access to nearly
all iDRAC6 features. You can inspect sensor
data, system event log records, and the current
status and configuration values maintained in
iDRAC6. You can alter iDRAC6 configuration
values, manage local users, enable and disable
features, and perform power functions such as
shutting down or rebooting the managed
server.

iVMCLI

The iDRAC6 Virtual Media Command Line
Interface (iVM-CLI) provides the managed
server access to media on the management
station. It is useful for developing scripts to
install operating systems on multiple
managed servers.

Configuring iDRAC6 Enterprise

39

Table 2-1. Configuration Interfaces (continued)
Interface

Description

SM-CLP

SM-CLP is the Server Management
Workgroup Server Management-Command
Line Protocol (SM-CLP) implementation
incorporated in iDRAC6. The SM-CLP
command line is accessed by logging in to
iDRAC6 using telnet or SSH.
SM-CLP commands implement a useful
subset of the local RACADM commands.
The commands are useful for scripting since
they can be executed from a management
station command line. The output of
commands can be retrieved in well-defined
formats, including XML, facilitating scripting
and integration with existing reporting and
management tools.
See "RACADM and SM-CLP Equivalencies"
for a comparison of the RACADM and
SM-CLP commands.

IPMI

IPMI defines a standard way for embedded
management subsystems, such as iDRAC6,
to communicate with other embedded systems
and management applications.
You can use the iDRAC6 Web interface,
SM-CLP, or RACADM commands to configure
IPMI Platform Event Filters (PEF) and
Platform Event Traps (PET).
PEF causes iDRAC6 to perform specific
actions (for example, rebooting the managed
server) when it detects a condition. PET
instructs iDRAC6 to send e-mail or IPMI alerts
when it detects specified events or conditions.
You can also use standard IPMI tools such as
IPMItool and ipmish with iDRAC6 when you
enable IPMI Over LAN.

40

Configuring iDRAC6 Enterprise

Configuration Tasks
This section is an overview of the configuration tasks for the management
station, iDRAC6, and the managed server. The tasks to be performed include
configuring iDRAC6 so that it can be used remotely, configuring iDRAC6
features you want to use, installing the operating system on the managed
server, and installing management software on your management station and
the managed server.
The configuration tasks that can be used to perform each task are listed
beneath the task.
NOTE: Before performing configuration procedures in this guide, the CMC and I/O
modules must be installed in the chassis and configured, and the PowerEdge server
must be physically installed in the chassis.

Configure the Management Station
Set up a management station by installing the Dell OpenManage software,
a Web browser, and other software utilities. See "Configuring the
Management Station."

Configure iDRAC6 Networking
Enable the iDRAC6 network and configure IP, netmask, gateway, and DNS
addresses.
NOTE: Access to iDRAC6 configuration through the iDRAC6 Configuration Utility
or Local RACADM CLI can be disabled by means of a RACADM command
(see "RACADM Subcommand Overview") or from the GUI (see "Enabling or Disabling
Local Configuration Access").
NOTE: Changing the iDRAC6 network settings terminates all current network
connections to iDRAC6.
NOTE: The option to configure the server using the LCD panel is available only
during the CMC initial configuration. Once the chassis is deployed, the LCD panel
cannot be used to reconfigure iDRAC6.
NOTE: The LCD panel can be used to enable DHCP to configure the iDRAC6
network. If you want to assign static addresses, you must use the iDRAC6
Configuration Utility or the CMC Web interface.

Configuring iDRAC6 Enterprise

41

•

Chassis LCD Panel — See the Dell Chassis Management Controller
Firmware User Guide

•

iDRAC6 Configuration Utility — See "Using the iDRAC6 Configuration
Utility"

•

CMC Web interface — See "Configuring Networking Using the CMC
Web Interface"

•

RACADM — See "cfgLanNetworking"

Configure iDRAC6 Users
Set up the local iDRAC6 users and permissions. iDRAC6 holds a table of
sixteen local users in firmware. You can set usernames, passwords, and roles
for these users.
•

iDRAC6 Configuration Utility (configures administrative user only) —
See "LAN User Configuration"

•

iDRAC6 Web interface — See "Adding and Configuring iDRAC6 Users"

•

RACADM — See "Adding an iDRAC6 User"
NOTE: When using iDRAC6 in an Active Directory environment, the user names you
create must conform to the Active Directory naming convention in force.

Configure Active Directory
In addition to the local iDRAC6 users, you can use Microsoft® Active
Directory® to authenticate iDRAC6 user logins.
For more information, see "Using iDRAC6 With Microsoft Active Directory."
NOTE: When using iDRAC6 in an Active Directory environment, be sure your user
names conform to the Active Directory naming convention in force.

Configure IP Filtering and IP Blocking
In addition to user authentication, you can prevent unauthorized access by
rejecting connection attempts from IP addresses outside of a defined range
and by temporarily blocking connections from IP addresses where
authentication has failed multiple times within a configurable timespan.

42

•

iDRAC6 Web interface — See "Configuring IP Filtering and IP Blocking"

•

RACADM — See "Configuring IP Filtering (IP Range)" and "Configuring
IP Blocking"
Configuring iDRAC6 Enterprise

Configure Platform Events
Platform events occur when iDRAC6 detects a warning or critical condition
from one of the managed server’s sensors.
Configure Platform Event Filters (PEF) to choose the events you want to
detect, such as rebooting the managed server, when an event is detected.
•

iDRAC6 Web interface — See "Configuring Platform Event Filters (PEF)"

•

RACADM — See "Configuring PEF"

Configure Platform Event Traps (PET) to send alert notifications to an
IP address, such as a management station with IPMI software or to send an
e-mail to a specified e-mail address.
•

iDRAC6 Web interface — See "Configuring Platform Event Traps (PET)"

•

RACADM — See "Configuring PET"

Enabling or Disabling Local Configuration Access
Access to critical configuration parameters, such as network configuration
and user privileges, can be disabled. Once disabled, the setting remains
persistent across reboots. Configuration write access is blocked for both the
Local RACADM program and the iDRAC6 Configuration Utility (at boot).
Web access to configuration parameters is unimpeded and configuration data
is always available for viewing. For information about the iDRAC6 Web
interface, see "Enabling or Disabling Local Configuration Access."
For cfgRacTuning commands, see "cfgRacTuning."

Configure iDRAC6 Services
Enable or disable iDRAC6 network services — such as telnet, SSH, and the
Web server interface — and reconfigure ports and other service parameters.
•

iDRAC6 Web interface — See "Configuring iDRAC6 Services"

•

RACADM — See "Configuring iDRAC6 Telnet and SSH Services Using
Local RACADM"

Configuring iDRAC6 Enterprise

43

Configure Secure Sockets Layer (SSL)
Configure SSL for the iDRAC6 Web server.
•

iDRAC6 Web interface — See "Secure Sockets Layer (SSL)"

•

RACADM — See "cfgRacSecurity," "sslcsrgen," "sslcertupload,"
"sslcertdownload," and "sslcertview"

Configure Virtual Media
Configure the virtual media feature so that you can install the operating
system on the PowerEdge server. Virtual media allows the managed server to
access media devices on the management station or ISO CD/DVD images on
a network share as if they were devices on the managed server.
•

iDRAC6 Web interface — See "Configuring and Using Virtual Media"

•

iDRAC6 Configuration Utility — See "Virtual Media Configuration"

Configure a VFlash Media Card
Install and configure a VFlash Media card for use with iDRAC6.
•

iDRAC6 Web interface — See "Configuring a VFlash Media Card for Use
With iDRAC6"

Install the Managed Server Software
Install the operating system on the PowerEdge server using virtual media and
then install the Dell OpenManage software on the managed PowerEdge
server and set up the last crash screen feature.
•

Console redirection — See "Installing the Software on the Managed Server"

•

iVMCLI — See "Using the Virtual Media Command Line Interface Utility"

Configure the Managed Server for the Last Crash Screen Feature
Set up the managed server so that iDRAC6 can capture the screen image after
an operating system crash or freeze.
•

44

Managed server — See "Configuring the Managed Server to Capture the
Last Crash Screen" and "Disabling the Windows Automatic Reboot Option"

Configuring iDRAC6 Enterprise

Configuring Networking Using the CMC Web
Interface
NOTE: You must have Chassis Configuration Administrator privilege to set up
iDRAC6 network settings from the CMC.
NOTE: The default CMC user is root and the default password is calvin.
NOTE: The CMC IP address can be found in the iDRAC6 Web interface by clicking
System→ Remote Access→ CMC. You can also launch the CMC Web interface
from this screen.

Launching the iDRAC6 Web-based Interface From the CMC
The CMC provides limited management of individual chassis components,
such as servers. For complete management of these individual components, the
CMC provides a launch point for the server’s iDRAC6 Web-based interface.
To launch iDRAC6 from the Servers screen:
1 Log in to the CMC Web interface.
2 In the system tree, select Servers.
The Servers Status screen appears.
3 Click the Launch iDRAC GUI icon for the server you want to manage.
You can also launch the iDRAC6 Web-based interface for a single server using
the Servers list in the system tree:
1 Log in to the CMC Web interface.
2 Expand Servers in the system tree.
All of the servers (1–16) appear in the expanded Servers list.
3 Click the server you want to view.
The Server Status screen for the server you selected displays.
4 Click the Launch iDRAC GUI icon.

Configuring iDRAC6 Enterprise

45

Single Sign-On

Using the single sign-on feature, you can launch the iDRAC6 Web-based
interface from the CMC without having to log in a second time. Single
sign-on policies are described below.
•

CMC user who has Server Administrator set under User Privileges will
automatically be logged in to the iDRAC6 Web-based interface using
single sign-on. After logging in, the user is automatically granted iDRAC6
Administrator privileges. This is true even if the same user does not have
an account on iDRAC6, or if the account does not have the
Administrator’s privileges.

•

CMC user who does not have Server Administrator set under
User Privileges, but has the same account on iDRAC6, will automatically
be logged in to iDRAC6 using single sign-on. Once logged in to the
iDRAC6 Web-based interface, this user is granted the privileges that were
created for the iDRAC6 account.
NOTE: In this context, "the same account" means that the user has the same
login name and password for CMC as for iDRAC6. A user who has the same
login name but a different password will not be recognized as a valid user.

•

CMC user who does not have Server Administrator set under User
Privileges, or the same account on iDRAC6, will not be automatically
logged in to iDRAC6 using single sign-on. This user is directed to the
iDRAC6 log in screen after clicking Launch iDRAC GUI.
NOTE: In this case, users may be prompted to log in to iDRAC6.
NOTE: If the iDRAC6 network LAN is disabled (LAN Enabled = No),
single sign-on is not available.

NOTE: If the server is removed from the chassis, the iDRAC6 IP address is
changed, or the iDRAC6 network connection experiences a problem,
then clicking the Launch iDRAC GUI icon may display an error screen.

46

Configuring iDRAC6 Enterprise

Configuring Networking for iDRAC6
1 Click the System→ Remote Access→ iDRAC.
2 Click the Network/Security tab:
To enable or disable Serial Over LAN:
a

Click Serial Over LAN.
The Serial Over LAN screen appears.

b

Select the Enable Serial Over LAN check box. You may also change
the Baud Rate and Channel Privilege Level Limit settings.

c

Click Apply.

To enable or disable IPMI Over LAN:
a

Click Network.
The Network Configuration screen appears.

b

Click IPMI LAN Settings.

c

Select the Enable IPMI Over LAN check box. You may also change
the Channel Privilege Level Limit and Encryption Key settings.

d

Click Apply.

To enable or disable DHCP:
a

Click Network.
The Network Configuration screen appears.

b

c

Click Network Settings.
•

To use DHCP for NIC IP address, select the Use DHCP (for NIC
IP Address) check box.

•

To use DHCP to obtain DNS server addresses, select the Use
DHCP to obtain DNS server addresses check box.

Click Apply.
NOTE: If you choose not to enable DHCP, you must enter the static
IP address, netmask, and default gateway for the server.

Configuring iDRAC6 Enterprise

47

Viewing FlexAddress Mezzanine Card Fabric
Connections
The M1000e includes FlexAddress, an advanced multilevel, multistandard
networking system. FlexAddress allows the use of persistent, chassis-assigned
World Wide Names and MAC addresses (WWN/MAC) for each managed
server port connection.
NOTE: In order to avoid errors that may lead to an inability to power on the
managed server, you must have the correct type of mezzanine card installed for
each port and fabric connection.
Configuration of the FlexAddress feature is performed using the CMC Web
interface. For more information on the FlexAddress feature and its configuration,
see your Dell Chassis Management Controller Firmware Version 2.0 User Guide.
After the FlexAddress feature has been enabled and configured for the chassis,
click System→ Properties→ WWN/MAC to view a list of installed mezzanine
cards, the fabrics and ports to which they are connected, the fabric port location,
type of fabric, and server-configured or chassis-assigned MAC addresses for each
installed embedded Ethernet and optional mezzanine card port.
To view a list of installed mezzanine cards, the type of mezzanine cards
installed, and if FlexAddress is configured, click System→ Properties→
Summary.

Updating iDRAC6 Firmware
Updating iDRAC6 firmware installs a new firmware image in flash memory.
You can update the firmware using any of the following methods:

48

•

SM-CLP load command

•

iDRAC6 Web interface

•

Dell Update Package (for Linux or Microsoft Windows)

•

DOS iDRAC6 Firmware update utility

•

CMC Web interface

Configuring iDRAC6 Enterprise

Downloading the Firmware or Update Package
Download the firmware from support.dell.com. The firmware image is available
in several different formats to support the different update methods available.
To update iDRAC6 firmware using the iDRAC6 Web interface or SM-CLP,
or to recover iDRAC6 using the CMC Web interface, download the binary
image, packaged as a self-extracting archive.
To update iDRAC6 firmware from the managed server, download the
operating system-specific Dell Update Package (DUP) for the operating
system running on the server whose iDRAC6 you are updating.
To update iDRAC6 firmware using the DOS iDRAC6 Firmware update
utility, download both the update utility and the binary image, which are
packaged in self-extracting archive files.

Executing the Firmware Update
NOTE: When the iDRAC6 firmware update begins, all existing iDRAC6 sessions
are disconnected and new sessions are not permitted until the update process
is completed.
NOTE: The chassis fans run at 100% during the iDRAC6 firmware update. When the
update is complete, normal fan speed regulation resumes. This is normal behavior,
designed to protect the server from overheating during a time when it cannot send
sensor information to the CMC.
To use a Dell Update Package for Linux or Microsoft Windows, execute the
operating-specific DUP on the managed server.
When using the SM-CLP load command, place the firmware binary image in
a directory where a Trivial File Transfer Protocol (TFTP) server can serve it to
iDRAC6. See "Updating iDRAC6 Firmware Using SM-CLP."
When using the iDRAC6 Web interface or the CMC Web interface, place
the firmware binary image on a disk that is accessible to the management
station from which you are running the Web interface. See "Updating
iDRAC6 Firmware."
NOTE: The iDRAC6 Web interface also allows you to reset iDRAC6 configuration to
the factory defaults.

Configuring iDRAC6 Enterprise

49

You can use the CMC Web interface or CMC RACADM to update the
iDRAC6 firmware. This feature is available both when iDRAC6 firmware is in
Normal mode, as well as when it is corrupted. See "Updating iDRAC6
Firmware Using the CMC."
NOTE: After the CMC updates iDRAC6 firmware, iDRAC6 generates new SHA1 and
MD5 keys for the SSL certificate. Because the keys are different from those in the
open Web browser, all browser windows that are connected to iDRAC6 must be
closed after the firmware update is complete. If the browser windows are not
closed, an Invalid Certificate error message is displayed.
NOTE: If you are rolling back iDRAC6 firmware to an earlier version, you must
delete the existing Internet Explorer ActiveX® browser plugin on any
Windows-based Management Station to allow the firmware to install a compatible
version of the ActiveX plugin. See "Deleting the ActiveX Plugin" for more
information.
Deleting the ActiveX Plugin

You must delete the existing Internet Explorer ActiveX browser plugin on any
Windows-based Management Station to allow the firmware to install a
compatible version of the ActiveX plugin.
To delete the ActiveX plugin in Internet Explorer 6:
1 Go to C:\WINDOWS\Downloaded Program Files.
2 Delete the file DELL IDRAC 11G AVCView.
To delete the ActiveX plugin in Internet Explorer 7:
1 Open Internet Explorer 7.
2 Press the  key to display the menu bar, if necessary.
3 Click Tools→ Manage Add-ons→ Enable or Disable Add-ons.
4 In the Manage Add-ons window, select Downloaded ActiveX Controls
(32-bit) from the Show drop-down menu.
5 In the Enabled list, click DELL IDRAC 11G AVCView, then click the
Delete button in the Delete ActiveX section.
6 Click OK.

50

Configuring iDRAC6 Enterprise

Using the iDRAC6 Web Interface
CAUTION: If iDRAC6 firmware becomes corrupted, as could occur if the iDRAC6
firmware update progress is interrupted before it completes, you can recover
iDRAC6 using the iDRAC6 Web interface.
NOTE: The firmware update, by default, retains the current iDRAC6 settings.
During the update process, you have the option to reset iDRAC6 configuration to the
factory defaults. If you set the configuration to the factory defaults, external
network access will be disabled when the update completes. You must enable and
configure the network using the iDRAC6 Configuration Utility.
1 Start the iDRAC6 Web interface.
2 In the system tree, select System→ Remote Access→ iDRAC.
3 Click the Update tab.
The Firmware Update screen appears.
NOTE: To update the firmware, iDRAC6 must be placed in an update mode.
Once in this mode, iDRAC6 will automatically reset, even if you cancel the
update process.

4 In the Upload (Step 1 of 4) section, click Browse to locate the firmware
image that you downloaded. You can also enter the path in the text field.
For example:
C:\Updates\V2.0\.
The default firmware image name is firmimg.imc.
5 Click Upload.
The file uploads to iDRAC6. This may take several minutes to complete.
NOTE: During the upload process, you abort the firmware upgrade process
by clicking Cancel. Clicking Cancel resets iDRAC6 to normal operating mode.

When the upload is complete, the Firmware Update - Validation (page 2
of 4) screen displays.
•

If the image file uploaded successfully and passed all verification checks,
a message appears indicating that the firmware image has been verified.

•

If the image did not upload successfully, or it did not pass the
verification checks, the firmware update returns to the Firmware
Update screen. You can try upgrading iDRAC6 again or click Cancel
to reset iDRAC6 to normal operating mode.
Configuring iDRAC6 Enterprise

51

NOTE: If you deselect the Preserve Configuration check box, iDRAC6 resets
to its default settings. In the default settings, the LAN is disabled, and you
cannot log in to the iDRAC6 Web interface. You must reconfigure the
LAN settings using the iDRAC6 Configuration Utility during BIOS POST.

6 By default, the Preserve Configuration option is enabled (checked) to preserve
the current settings on iDRAC6 after an upgrade. If you do not want the
settings to be preserved, clear the Preserve Configuration check box.
7 Click Begin Update to start the upgrade process. Do not interrupt the
upgrade process.
8 The Firmware Update - Updating (page 3 of 4) window, you will see the
status of the upgrade. The progress of the firmware upgrade operation,
measured in percentages, will appear in the Progress column.
9 Once the firmware update is complete, the Firmware Update - Update
Results (page 4 of 4) window will appear and iDRAC6 will reset
automatically. You must close the current browser window and reconnect
to iDRAC6 using a new browser window.

Using the DOS Update Utility
To update iDRAC6 firmware using the DOS update utility, boot the managed
server to DOS, and execute the idrac16d command. The syntax for the
command is:
idrac16d [-f] [-i=] [-l=]
When executed with no options, the idrac16d command updates iDRAC6
firmware using the firmware image file firmimg.imc in the current directory.
The options are as follows:

52

•

-f — Forces the update. The -f option can be used to downgrade the
firmware to an earlier image.

•

-i= — Specifies the file name of the firmware image.
This option is required if the firmware file name has been changed from
the default name firmimg.imc.

•

-l= — Logs output from the update activity. This option is
used for debugging.

Configuring iDRAC6 Enterprise

NOTE: If you enter incorrect arguments to the idrac16d command, or supply
the -h option, you may notice an additional option, -nopresconfig in the
usage output. This option is used to update the firmware without preserving any
configuration information. You should not use this option unless explicitly told to do
so by a Dell Support Representative, because it deletes all of your existing iDRAC6
configuration information such as IP addresses, users, and passwords.

Verifying the Digital Signature
A digital signature is used to authenticate the identity of the signer of a file
and to certify that the original content of the file has not been modified since
it was signed.
If you do not already have it installed on your system, you must install the
Gnu Privacy Guard (GPG) to verify a digital signature. To use the standard
verification procedure, perform the following steps:
1 Download the Dell Linux public GnuPG key, if you do not already have it,
by navigating to lists.us.dell.com and clicking the Dell Public GPG key
link. Save the file to your local system. The default name is linux-securitypublickey.txt.
2 Import the public key to your gpg trust database by running the following
command:
gpg --import 
NOTE: You must have your private key to complete the process.
3 To avoid a distrusted-key warning, change the trust level for the Dell
Public GPG key.
a

Enter the following command:
gpg --edit-key 23B66A9D

b

Within the GPG key editor, enter fpr. The following message
appears:
pub 1024D/23B66A9D 2001-04-16 Dell, Inc.
(Product Group) 
Primary key fingerprint: 4172 E2CE 955A 1776
A5E6 1BB7 CA77 951D 23B6 6A9D
If the fingerprint of your imported key is the same as above, you have a
correct copy of the key.

Configuring iDRAC6 Enterprise

53

c

While still in the GPG key editor, enter trust. The following menu
appears:
Please decide how far you trust this user to
correctly verify other users' keys (by looking
at passports, checking fingerprints from
different sources, etc.)
1
2
3
4
5
m

=
=
=
=
=
=

I don't know or won't say
I do NOT trust
I trust marginally
I trust fully
I trust ultimately
back to the main menu

Your decision?
d

Enter 5, then press . The following prompt appears:
Do you really want to set this key to ultimate
trust? (y/N)

e

Enter y  to confirm your choice.

f

Enter quit  to exit the GPG key editor.

You must import and validate the public key only once.
4 Obtain the package you need, for example the Linux DUP or selfextracting archive) and its associated signature file from the Dell Support
website at support.dell.com/support/downloads.
NOTE: Each Linux Update Package has a separate signature file, which is
shown on the same Web page as the Update Package. You need both the
Update Package and its associated signature file for verification. By default,
the signature file is named the same as the DUP filename with a .sign
extension. For example, the iDRAC6 firmware image has an associated .sign
file (IDRAC_FRMW_LX_2.0.BIN.sign), which is included in the self-extracting
archive with the firmware image (IDRAC_FRMW_LX_2.0.BIN). To download
the files, right-click on the download link and use the Save Target As…
file option.

54

Configuring iDRAC6 Enterprise

5 Verify the Update Package:
gpg --verify  
The following example illustrates the steps that you should follow to verify a
Dell PowerEdge™ M610 iDRAC Update Package:
1 Download the following two files from support.dell.com:
•

IDRAC_FRMW_LX_2.0.BIN.sign

•

IDRAC_FRMW_LX_2.0.BIN

2 Import the public key by running the following command line:
gpg --import 
The following output message appears:
gpg: key 23B66A9D: "Dell Computer Corporation
(Linux Systems Group) " not changed
gpg: Total number processed: 1
gpg: unchanged: 1
3 Set the GPG trust level for the Dell public key, if you haven’t done so
previously.
a

Enter the following command:
gpg --edit-key 23B66A9D

b

At the command prompt, enter the following commands:
fpr
trust

c

Enter 5, then press  to choose I trust ultimately
from the menu.

d

Enter y  to confirm your choice.

e

Enter quit  to exit the GPG key editor.

This completes validation of the Dell public key.

Configuring iDRAC6 Enterprise

55

4 Verify the PowerEdge M610 iDRAC package digital signature by running
the following command:
gpg --verify IDRAC_FRMW_LX_2.0.BIN.sign
IDRAC_FRMW_LX_2.0.BIN
The following output message appears:
gpg: Signature made Fri Jul 11 15:03:47 2008
CDT using DSA key ID 23B66A9D
gpg: Good signature from "Dell, Inc. (Product
Group) "
NOTE: If you have not validated the key as shown in step 3, you will receive
additional messages:

gpg: WARNING: This key is not certified with a
trusted signature!
gpg: There is no indication that the signature
belongs to the owner.
Primary key fingerprint: 4172 E2CE 955A 1776
A5E6 1BB7 CA77 951D 23B6 6A9D

Clear Your Browser’s Cache
To be able to use the features in the latest iDRAC6, you must clear the
browser’s cache to remove/delete any old Web pages that may be stored on
the system.
Internet Explorer 6

1 Start Internet Explorer.
2 Click Tools, and then click Internet Options.
The Internet Options window appears.
3 Click the General tab.
4 Under Temporary Internet files, click Delete Files.
The Delete Files window appears.
5 Click to check Delete all offline content, and then click OK.
6 Click OK to close the Internet Options window.

56

Configuring iDRAC6 Enterprise

Internet Explorer 7

1 Start Internet Explorer.
2 Click Tools, and then click Internet Options...
The Internet Options window appears.
3 Click the General tab.
4 Under Browsing history, click Delete...
The Delete Files window appears.
5 Click Delete files next to Temporary Internet Files.
6 Click Close, and then click OK to exit the Internet Options window.
Firefox

1 Start Firefox.
2 Click Edit→ Preferences.
3 Click the Privacy tab.
4 Click the Clear Cache Now.
5 Click Close.

Updating the USC Repair Package
See the Dell Unified Server Configurator User Guide for information on
updating the USC repair package from the iDRAC6 Web interface.

Configuring iDRAC6 For Use With IT Assistant
Dell OpenManage IT Assistant can discover managed devices that comply
with Simple Network Management Protocol (SNMP) v1and v2c and
Intelligent Platform Management Interface (IPMI) v2.0.
iDRAC6 complies with IPMI v2.0. This section describes the steps necessary
to configure iDRAC6 for discovery and monitoring by IT Assistant. There are
two ways to accomplish this: through the iDRAC6 Configuration Utility and
through the iDRAC6 graphical Web interface.

Configuring iDRAC6 Enterprise

57

Using the iDRAC6 Configuration Utility to Enable Discovery and
Monitoring
To set up iDRAC6 for IPMI discovery and alert trap sending at the iDRAC6
Configuration Utility level, restart your managed server (blade) and observe
its power-up using the iKVM and either a remote monitor and console
keyboard or a Serial over LAN (SOL) connection. When Press
 for Remote Access Setup displays, press .
When the iDRAC Configuration Utility screen appears, use the arrow keys
to scroll down.
1 Enable IPMI over LAN.
2 Enter your site's RMCP+ Encryption Key, if used.
NOTE: See your senior Network Administrator or CIO to discuss implementing
this option because it adds valuable security protection and must be implemented
site-wide in order to function properly.
3 At LAN Parameters, press  to enter the sub-screen. Use Up and
Down arrows to navigate.
4 Toggle LAN Alert Enabled to On using the spacebar.
5 Enter the IP address of your Management Station into Alert Destination 1.
6 Enter a name string into iDRAC6 Name with a consistent naming convention
across your data center. The default is iDRAC6-{Service Tag}.
Exit the iDRAC6 Configuration Utility by pressing , , and then
pressing  to save your changes. Your server will now boot into normal
operation, and it will be discovered during IT Assistant's next scheduled
Discovery pass.

Using the iDRAC6 Web Interface to Enable Discovery and Monitoring
IPMI Discovery can also be enabled through the remote Web interface:
1 Open a supported Web browser window.
2 Log in to the iDRAC6 Web-based interface using a login and password
with Administrator rights.
3 In the system tree, select System→ Remote Access→ iDRAC.
4 Click the Network/Security tab.
The Network Configuration screen appears.
58

Configuring iDRAC6 Enterprise

5 Click IPMI LAN Settings.
6 Ensure the Enable IPMI over LAN check box is selected (checked).
7 Select Administrator from the Channel Level Privileges drop-down
menu.
8 Enter your site's RMCP+ Encryption Key, if used.
9 Click Apply if you made any changes on this screen.
10 In the system tree, select System.
11 Click the Alert Management tab, and then click Platform Events.
The Platform Events screen appears, displaying a list of events for which
you can configure iDRAC6 to generate email alerts.
12 Enable email alerts for one or more events by selecting the check box in
the Generate Alerts column.
13 Click Apply if you made any changes on this screen.
14 Click Trap Settings.
The Platform Event Alert Destinations screen appears.
15 In the first available Destination IP Address field in the IPv4 Destination
List section, select the Enabled check box, and then enter the IP address
of your Management Station.
16 Click Apply if you made any changes on this screen.
You can now send a test trap by clicking the Send link in the Test Trap column.
Dell highly recommends that for security purposes you create a separate User
for IPMI commands with its own user name, IPMI over LAN privileges,
and password:
1 In the system tree, select System→ Remote Access→ iDRAC.
2 Click the Network Security tab, and then click Users.
The Users screen appears, displaying a list of all users (defined or
undefined).
3 Click the User ID of an undefined User.
The User Configuration screen for the selected User ID appears.
4 Select the Enable User check box, and then enter the user’s name
and password.
Configuring iDRAC6 Enterprise

59

5 In the IPMI LAN Privilege section, ensure that Maximum LAN User
Privilege Granted is set to Administrator.
6 Set other user privileges as needed.
7 Click Apply to save the new User settings.

Using IT Assistant to View iDRAC6 Status and Events
After discovery is complete, the iDRAC6 devices appear in the Servers
category of the ITA Devices detail screen, and iDRAC6 information can be
seen by clicking on the iDRAC6 name. This is different than DRAC5 systems,
where the management card shows up in the RAC group. This is due to the
fact that iDRAC6 uses IPMI discovery as opposed to SNMP.
iDRAC6 error and warning traps can now be seen in the primary Alert Log of
IT Assistant. They will show up in the Unknown category, but the trap
description and severity will be accurate.
For more information on using IT Assistant to manage your data center,
see the Dell OpenManage IT Assistant User's Guide.

60

Configuring iDRAC6 Enterprise

Configuring the Management
Station
A management station is a computer used to monitor and manage the
PowerEdge servers and other modules in the chassis. This section describes
software installation and configuration tasks that set up a management
station to work with iDRAC6 Enterprise. Before you begin configuring
iDRAC6, follow the procedures in this section to ensure that you have
installed and configured the tools you will need.

Management Station Set Up Steps
To set up your Management Station, perform the following steps:
1 Set up the management station network.
2 Install and configure a supported Web browser.
3 Install a Java Runtime Environment (JRE) (optional for Windows).
4 Install telnet or SSH clients, if required.
5 Install a TFTP server, if required.
6 Install Dell OpenManage IT Assistant (optional).

Management Station Network Requirements
To access iDRAC6, the management station must be on the same network as
the CMC RJ45 connection port labelled "GB1". It is possible to isolate the
CMC network from the network the managed server is on, so that your
management station may have LAN access to iDRAC6 but not to the
managed server.

Configuring the Management Station

61

Using the iDRAC6 console redirection feature (see "Configuring and Using
Serial Over LAN"), you can access the managed server’s console even if you
do not have network access to the server’s ports. You can also perform several
management functions on the managed server, such as rebooting the
computer, using iDRAC6 facilities. To access network and application services
hosted on the managed server, however, you may need an additional NIC in
the management computer.

Configuring a Supported Web Browser
The following sections provide instructions for configuring the supported
Web browsers for use with the iDRAC6 Web interface. For a list of supported
Web browsers, see "Supported Web Browsers."

Opening Your Web Browser
The iDRAC6 Web interface is designed to be viewed in a supported Web
browser at a minimum screen resolution of 800 pixels wide by 600 pixels high.
In order to view the interface and access all features, ensure that your
resolution is set to at least 800 by 600 pixels and/or resize your browser, as
needed.
NOTE: In some situations, most often during the first session after a firmware
update, users of Internet Explorer 6 may see the message Done, with errors
displayed in the browser status bar along with a partially rendered screen in the
main browser window. This error can also occur if you are experiencing
connectivity problems. This is a known issue with Internet Explorer 6. Close the
browser and start again.

Configuring Your Web Browser to Connect to the Web Interface
If you are connecting to the iDRAC6 Web interface from a management
station that connects to the Internet through a proxy server, you must
configure the Web browser to access the Internet from this server.
To configure the Internet Explorer Web browser to access a proxy server,
perform the following steps:
1 Open a Web browser window.
2 Click Tools, and click Internet Options.
The Internet Options window appears.

62

Configuring the Management Station

3 Select Tools→ Internet Options→ Security→ Local Network.
4 Click the Custom Level.
5 Select Medium-Low from the drop-down menu and click Reset. Click OK
to confirm. You will need to re-enter the Custom Level dialog by clicking
its button.
6 Then, scroll down to the section labeled ActiveX controls and plug-ins and
check each setting, as different versions of IE have differing settings in
Medium-Low state:
•

Automatic prompting for ActiveX controls: Enable

•

Binary and script behaviors: Enable

•

Download signed ActiveX controls: Prompt

•

Initialize and script ActiveX controls not marked as safe: Prompt

•

Run ActiveX controls and plug-ins: Enable

•

Script ActiveX controls marked safe for scripting: Enable

In the section on Downloads:
•

Automatic prompting for file downloads: Enable

•

File download: Enable

•

Font download: Enable

In the Miscellaneous section:
•

Allow META-REFRESH: Enable

•

Allow scripting of Internet Explorer Web browser control: Enable

•

Allow script-initiated windows without size or position constraints:
Enable

•

Don't prompt for client certificate selection when no certificates or
only one certificate exists: Enable

•

Launching programs and files in an IFRAME: Enable

•

Open files based on content, not file extension: Enable

•

Software channel permissions: Low safety

•

Submit nonencrypted form data: Enable

•

Use Pop-up Blocker: Disable

Configuring the Management Station

63

In the Scripting section:
•

Active scripting: Enable

•

Allow paste operations via script: Enable

•

Scripting of Java applets: Enable

7 Select Tools→ Internet Options→ Advanced.
8 Make sure the following items are checked or unchecked:
In the Browsing section:
•

Always send URLs as UTF-8: checked

•

Disable script debugging (Internet Explorer): checked

•

Disable script debugging: (Other): checked

•

Display a notification about every script error: unchecked

•

Enable Install On demand (Other): checked

•

Enable page transitions: checked

•

Enable third-party browser extensions: checked

•

Reuse windows for launching shortcuts: unchecked

In the HTTP 1.1 settings section:
•

Use HTTP 1.1: checked

•

Use HTTP 1.1 through proxy connections: checked

In the Java (Sun) section:
•

Use JRE 1.6.x_yz: checked (optional; version may differ)

In the Multimedia section:
•

Enable automatic image resizing: checked

•

Play animations in Web pages: checked

•

Play videos in Web pages: checked

•

Show pictures: checked

In the Security section:

64

•

Check for publishers' certificate revocation: unchecked

•

Check for signatures on downloaded programs: unchecked

Configuring the Management Station

•

Check for signatures on downloaded programs: checked

•

Use SSL 2.0: unchecked

•

Use SSL 3.0: checked

•

Use TLS 1.0: checked

•

Warn about invalid site certificates: checked

•

Warn if changing between secure and not secure mode: checked

•

Warn if forms submittal is being redirected: checked
NOTE: If you choose to alter any of the above settings, Dell recommends that
you learn and understand the consequences of doing so. For example, if you
choose to block pop-ups, portions of the iDRAC6 Web interface will not
function properly.

9 Click Apply, then OK.
10 Click the Connections tab.
11 Under Local Area Network (LAN) settings, click LAN Settings.
12 If the Use a proxy server box is selected, select the Bypass proxy server for
local addresses box.
13 Click OK twice.
14 Close and restart your browser to make sure all changes take effect.

Adding iDRAC6 to the List of Trusted Domains
When you access the iDRAC6 Web interface through the Web browser,
you may be prompted to add the iDRAC6 IP address to the list of trusted
domains if the IP address is missing from the list. When completed,
click Refresh or relaunch the Web browser to establish a connection to the
iDRAC6 Web interface.

Viewing Localized Versions of the Web Interface
The iDRAC6 Web interface is supported on the following operating system
languages:
•

English (en-us)

•

French (fr)

•

German (de)

Configuring the Management Station

65

•

Spanish (es)

•

Japanese (ja)

•

Simplified Chinese (zh-cn)

The ISO identifiers in parentheses denote the specific language variants
which are supported. Use of the interface with other dialects or languages is
not supported and may not function as intended. For some supported
languages, resizing the browser window to 1024 pixels wide may be necessary
in order to view all features.
The iDRAC6 Web interface is designed to work with localized keyboards for
the specific language variants listed above. Some features of the iDRAC6
Web interface, such as Console Redirection, may require additional steps to
access certain functions/letters. For more details on how to use localized
keyboards in these situations, see "Using the Video Viewer." Use of other
keyboards is not supported and may cause unexpected problems.
Internet Explorer 6.0 (Windows)

To view a localized version of the iDRAC6 Web interface in Internet Explorer,
perform the following steps:
1 Click the Tools menu and select Internet Options.
2 In the Internet Options window, click Languages.
3 In the Language Preference window, click Add.
4 In the Add Language window, select a supported language.
To select more than one language, press .
5 Select your preferred language and click Move Up to move the language to
the top of the list.
6 In the Language Preference window, click OK.
7 Click OK.
Firefox 2.0 (Linux or Windows)

To view a localized version of the iDRAC6 Web interface in Firefox 2.0,
perform the following steps:
1 Click Tools→ Options, and then click the Advanced tab.
2 Under Language, click Choose.
The Languages window appears.
66

Configuring the Management Station

3 In the Select a language to add... drop down menu, click to highlight a
supported language, and then click Add.
4 Click to select your preferred language, and then click Move Up until the
language appears a the top of the list.
5 Click OK to close the Languages window.
6 Click OK to close the Options window.

Setting the Locale in Linux
The console redirection viewer requires a UTF-8 character set to display
correctly. If your display is garbled, check your locale and reset the character
set if needed.
To set the character set on a Linux client with a Simplified Chinese GUI:
1 Open a command terminal.
2 Enter locale and press . Output similar to the following
output appears:
LANG=zh_CN.UTF-8
LC_CTYPE="zh_CN.UTF-8"
LC_NUMERIC="zh_CN.UTF-8"
LC_TIME="zh_CN.UTF-8"
LC_COLLATE="zh_CN.UTF-8"
LC_MONETARY="zh_CN.UTF-8"
LC_MESSAGES="zh_CN.UTF-8"
LC_PAPER="zh_CN.UTF-8"
LC_NAME="zh_CN.UTF-8"
LC_ADDRESS="zh_CN.UTF-8"
LC_TELEPHONE="zh_CN.UTF-8"
LC_MEASUREMENT="zh_CN.UTF-8"
LC_IDENTIFICATION="zh_CN.UTF-8"
LC_ALL=
3 If the values include zh_CN.UTF-8, no changes are required. If the
values do not include zh_CN.UTF-8, go to step 4.
4 Edit the /etc/sysconfig/i18n file with a text editor.

Configuring the Management Station

67

5 In the file, apply the following changes:
Current entry:
LANG="zh_CN.GB18030"
SUPPORTED="zh_CN.GB18030:zh_CH.GB2312:zh_CN:zh"
Updated entry:
LANG="zh_CN.UTF-8"
SUPPORTED="zh_CN.UTF8:zh_CN.GB18030:zh_CH.GB2312:zh_CN:zh"
6 Log out and then log in to the operating system.
When you switch from any other language, ensure that this fix is still valid.
If not, repeat this procedure.

Disabling the Whitelist Feature in Firefox
Firefox has a "whitelist" security feature that requires user permission to
install plugins for each distinct site that hosts a plugin. If enabled, the
whitelist feature requires you to install a console redirection viewer for each
iDRAC6 you visit, even though the viewer versions are identical.
To disable the whitelist feature and avoid unnecessary plugin installations,
perform the following steps:
1 Open a Firefox Web browser window.
2 In the address field, enter about:config and press .
3 In the Preference Name column, locate and double-click
xpinstall.whitelist.required.
The values for Preference Name, Status, Type, and Value change to
bold text. The Status value changes to user set and the Value value
changes to false.
4 In the Preferences Name column, locate xpinstall.enabled.
Ensure that Value is true. If not, double-click xpinstall.enabled to set
Value to true.

68

Configuring the Management Station

Installing a Java Runtime Environment (JRE)
NOTE: If you use the Internet Explorer browser, an ActiveX control is provided for
the console viewer. You can also use the Java console viewer with Internet
Explorer if you install a JRE and configure the console viewer in iDRAC6 Web
interface before you launch the viewer. See "Configuring Console Redirection and
Virtual Media in the iDRAC6 Web Interface" for more information.
You can choose to use the Java viewer instead before you launch the viewer.
If you use the Firefox browser you must install a JRE (or a Java Development
Kit [JDK]) to use the console redirection feature. The console viewer is a
Java application that is downloaded to the management station from the
iDRAC6 Web interface and then launched with Java Web Start on the
management station.
Go to java.sun.com to install a JRE or JDK. Version 1.6 (Java 6.0) or higher is
recommended.
The Java Web Start program is automatically installed with the JRE or JDK.
The file jviewer.jnlp is downloaded to your desktop and a dialog box prompts
you for what action to take. It may be necessary to associate the .jnlp
extension type with the Java Web Start application in your browser.
Otherwise, click Open with and then select the javaws application, which is
located in the bin subdirectory of your JRE installation directory.
NOTE: If the .jnlp file type is not associated with Java Web Start after installing JRE
or JDK, you can set the association manually. For Windows (javaws.exe) click
Start→ Control Panel→ Appearance and Themes→ Folder Options. Under the File
Types tab, highlight .jnlp under Registered file types, and then click Change. For
Linux (javaws), start Firefox, and click Edit→ Preferences→ Downloads, and then
click View and Edit Actions.
For Linux, once you have installed either JRE or JDK, add a path to the Java
bin directory to the front of your system PATH. For example, if Java is
installed in /usr/java, add the following line to your local .bashrc or /etc/
profile:
PATH=/usr/java/bin:$PATH; export PATH
NOTE: There may already be PATH-modification lines in the files. Ensure that the
path information you enter does not create conflicts.

Configuring the Management Station

69

Installing Telnet or SSH Clients
By default, the iDRAC6 telnet service is disabled and the SSH service is
enabled. Since telnet is an insecure protocol, you should use it only if you
cannot install an SSH client or your network connection is otherwise secured.
NOTE: There can be only one active telnet or SSH connection to iDRAC6 at a time.
When there is an active connection, other connection attempts are denied.

Telnet with iDRAC6
Telnet is included in Windows and Linux operating systems, and can be run
from a command shell. You may also choose to install a commercial or freely
available telnet client with more convenience features than the standard
version included with your operating system.
If your management station is running Windows XP SP1 or Windows 2003,
you may experience an issue with the characters in an iDRAC6 telnet
session.This issue may occur as a frozen login where the return key does not
respond and the password prompt does not appear.
To fix this issue, download hotfix 824810 from the Microsoft Support website
at support.microsoft.com. See Microsoft Knowledge Base article 824810 for
more information.
NOTE: The hotfix is needed only for Windows XP SP1 and Windows 2003.
Windows XP SP2 fixed the issue.

Configuring the Backspace Key For Telnet Sessions
Depending on the telnet client, using the  key may produce
unexpected results. For example, the session may echo ^h. However,
most Microsoft and Linux telnet clients can be configured to use the
 key.
To configure Microsoft telnet clients to use the  key,
perform the following steps:
1 Open a command prompt window (if required).
2 If you are not running a telnet session, enter:
telnet
If you are running a telnet session, press <]>.

70

Configuring the Management Station

3 At the prompt, enter:
set bsasdel
The following message appears:
Backspace will be sent as delete.
To configure a Linux telnet session to use the  key, perform the
following steps:
1 Open a shell and enter:
stty erase ^h
2 At the prompt, enter:
telnet

SSH With iDRAC6
Secure Shell (SSH) is a command line connection with the same capabilities
as a telnet session, but with session negotiation and encryption to improve
security. iDRAC6 supports SSH version 2 with password authentication.
SSH is enabled by default on iDRAC6.
You can use PuTTY (Windows) or OpenSSH (Linux) on a management
station to connect to the managed server’s iDRAC6. When an error occurs
during the login procedure, the ssh client issues an error message.
The message text is dependent on the client and is not controlled
by iDRAC6.
NOTE: OpenSSH should be run from a VT100 or ANSI terminal emulator on
Windows. Running OpenSSH at the Windows command prompt does not result in
full functionality (that is, some keys do not respond and no graphics are displayed).
Only one telnet or SSH session is supported at any given time. The session
timeout is controlled by the cfgSsnMgtSshIdleTimeout property as
described in "iDRAC6 Enterprise Property Database Group and Object
Definitions."
iDRAC6 SSH implementation supports multiple cryptography schemes,
as shown in Table 3-1.
NOTE: SSHv1 is not supported.

Configuring the Management Station

71

Table 3-1.

Cryptography Schemes

Scheme Type

Scheme

Asymmetric Cryptography

Diffie-Hellman DSA/DSS 512-1024 (random)
bits per NIST specification

Symmetric Cryptography

• AES256-CBC
• RIJNDAEL256-CBC
• AES192-CBC
• RIJNDAEL192-CBC
• AES128-CBC
• RIJNDAEL128-CBC
• BLOWFISH-128-CBC
• 3DES-192-CBC
• ARCFOUR-128

Message Integrity

• HMAC-SHA1-160
• HMAC-SHA1-96
• HMAC-MD5-128
• HMAC-MD5-96

Authentication

• Password

Installing a TFTP Server
NOTE: If you use only the iDRAC6 Web interface to transfer SSL certificates and
upload new iDRAC6 firmware, no TFTP server is required.
Trivial File Transfer Protocol (TFTP) is a simplified form of the File Transfer
Protocol (FTP). It is used with the SM-CLP and RACADM command line
interfaces to transfer files to and from iDRAC6.
The only times when you need to copy files to or from iDRAC6 are when you
update iDRAC6 firmware or install certificates on iDRAC6. If you choose to
use SM-CLP or RACADM when you perform these tasks, a TFTP server must
be running on a computer iDRAC6 can access by IP number or DNS name.

72

Configuring the Management Station

You can use the netstat -a command on Windows or Linux operating systems
to see if a TFTP server is already listening. Port 69 is the TFTP default port.
If no server is running, you have the following options:
•

Find another computer on the network running a TFTP service

•

If you are using Linux, install a TFTP server from your distribution

•

If you are using Windows, install a commercial or free TFTP server

Installing Dell OpenManage IT Assistant
Your system includes the Dell OpenManage System Management Software
Kit. This kit includes, but is not limited to, the following components:
•

Dell Systems Management Tools and Documentation DVD

•

Dell Support website and Readme files — Check Readme files and the
Dell Support website at support.dell.com for the most recent information
about your Dell products.

Use the Dell Systems Management Tools and Documentation DVD to install the
management console software, including Dell OpenManage IT Assistant,
on the management station. For instructions on installing this software,
see your Dell OpenManage Software Quick Installation Guide.

Configuring the Management Station

73

74

Configuring the Management Station

Configuring the Managed Server
This section describes tasks to set up the managed server to enhance
your remote management capabilities. These tasks include installing the
Dell Open Manage Server Administrator software and configuring the
managed server to capture the last crash screen.

Installing the Software on the Managed Server
The Dell management software includes the following features:
•

Local RACADM CLI — Allows you to configure and administer iDRAC6
from the managed server. It is a powerful tool for scripting configuration
and management tasks.

•

Server Administrator — Is required to use the iDRAC6 last-crash-screen
feature.

•

Server Administrator Instrumentation Service — Provides access to
detailed fault and performance information gathered by industry-standard
systems management agents and allows remote administration of
monitored systems, including shutdown, startup, and security.

•

Server Administration Storage Management Service — Provides storage
management information in an integrated graphical view.

•

Server Administrator Logs — Displays logs of commands issued to or by
the system, monitored hardware events, POST events, and system alerts.
You can view logs on the home page, print or save them as reports,
and send them by e-mail to a designated service contact.

Use the Dell Systems Management Tools and Documentation DVD to install
Server Administrator. For instructions on installing this software, see your
Quick Installation Guide.

Configuring the Managed Server

75

Configuring the Managed Server to Capture the
Last Crash Screen
iDRAC6 can capture the last crash screen so that you can view it in the Web
interface to help troubleshoot the cause of the managed server crash.
Follow these steps to enable the last crash screen feature.
1 Install the managed server software. For more information about installing
the managed server software, see the Dell OpenManage Server
Administrator User’s Guide.
2 If you are running Windows, ensure that Automatically Reboot is
deselected in the Windows Startup and Recovery Settings. See "Disabling
the Windows Automatic Reboot Option."
3 Enable the Last Crash Screen (disabled by default) in the iDRAC6
Web interface.
To enable the Last Crash Screen in the iDRAC6 Web interface,
click System→ Remote Access→ iDRAC→ Network/Security→ Services,
then check the Enable checkbox under the Automatic System Recovery
Agent Settings heading.
To enable the Last Crash Screen using local RACADM, open a command
prompt on the managed server and enter the following command:
racadm config -g cfgRacTuning -o
cfgRacTuneAsrEnable 1
4 In the Server Administrator Web-based interface, enable the Auto
Recovery timer and set the Auto Recovery action to Reset, Power Off,
or Power Cycle.
For information about how to configure the Auto Recovery timer, see the
Server Administrator User's Guide. To ensure that the last crash screen can
be captured, the Auto Recovery timer should be set to 60 seconds.
The default setting is 480 seconds.
The last crash screen is not available when the Auto Recovery action is set
to Shutdown or Power Cycle if the managed server is powered off.

76

Configuring the Managed Server

Disabling the Windows Automatic Reboot Option
To ensure that iDRAC6 can capture the last crash screen, disable the
Automatic Reboot option on managed servers running Windows Server or
Windows Vista.
1 Open the Windows Control Panel and double-click the System icon.
2 Click the Advanced tab.
3 Under Startup and Recovery, click Settings.
4 Deselect the Automatically Reboot check box.
5 Click OK twice.

Configuring the Managed Server

77

78

Configuring the Managed Server

Configuring iDRAC6 Enterprise
Using the Web Interface
iDRAC6 provides a Web interface that enables you to configure iDRAC6
properties and users, perform remote management tasks, and troubleshoot a
remote (managed) system for problems. For everyday systems management,
use the iDRAC6 Web interface. This chapter provides information about how
to perform common systems management tasks with the iDRAC6 Web
interface and provides links to related information.
Most Web interface configuration tasks can also be performed with local
RACADM commands or with SM-CLP commands.
Local RACADM commands are executed from the managed server. For more
information about local RACADM, see "Using the Local RACADM
Command Line Interface."
SM-CLP commands are executed in a shell that can be accessed remotely
with a telnet or SSH connection. For more information about SM-CLP,
see "Using iDRAC6 Enterprise SM-CLP Command Line Interface."

Configuring iDRAC6 Enterprise Using the Web Interface

79

Accessing the Web Interface
To access the iDRAC6 Web interface, perform the following steps:
1 Open a supported Web browser window.
See "Supported Web Browsers" for more information.
2 In the Address field, enter https:// and
press .
If the default HTTPS port number (port 443) has been changed, enter:
https://:
where iDRAC-IP-address is the IP address for iDRAC6 and port-number is
the HTTPS port number.
The iDRAC6 Login window appears.

Logging In
You can log in as either an iDRAC6 user or as a Microsoft® Active Directory®
user. The default user name and password are root and calvin, respectively.
You must have been granted Login to iDRAC privilege by the administrator
to log in to iDRAC6.
To log in, perform the following steps:
1 In the Username field, enter one of the following:
•

Your iDRAC6 user name.
The user name for local users is case sensitive. Examples are root,
it_user, or john_doe.

•

Your Active Directory user name.
You can use any of the following forms for Active Directory names:
\, /, or
@. They are not case sensitive. Examples are
dell.com\john_doe, or JOHN_DOE@DELL.COM. Alternatively,
you can enter the domain in the Domain field.

2 In the Password field, enter your iDRAC6 user password or Active
Directory user password. Passwords are case sensitive.
3 Click OK or press .
80

Configuring iDRAC6 Enterprise Using the Web Interface

Logging Out
1 In the upper-right corner of the main window, click Logout to close the
session.
2 Close the browser window.
NOTE: The Logout button does not appear until you log in.
NOTE: Closing the browser without gracefully logging out may cause the session
to remain open until it times out. It is strongly recommended that you click the
logout button to end the session; otherwise, the session may remain active until the
session timeout is reached.
NOTE: Closing the iDRAC6 Web interface within Internet Explorer using the close
button ("x") at the top right corner of the window may generate an application error.
To fix this issue, download the latest Cumulative Security Update for Internet
Explorer from the Microsoft Support website, located at support.microsoft.com.

Using Multiple Browser Tabs and Windows
Different versions of Web browsers exhibit different behaviors when opening
new tabs and windows. Each window is a new session, but each new tab is not.
Microsoft Internet Explorer 6 does not support tabs; therefore, each browser
window opened becomes a new iDRAC6 Web interface session. Internet
Explorer 7 has the option to open tabs as well as windows. Each tab inherits
the characteristics of the most recently opened tab. For example, if a user logs
in with Power User privileges on one tab, and then logs in as Administrator on
another tab, both open tabs then have Administrator privileges. Closing any
one tab expires all iDRAC6 Web interface tabs.
Tab behavior in Firefox 2 is the same as Internet Explorer 7; new tabs are new
sessions. Window behavior in Firefox is different. Firefox windows will
operate with the same privileges as the latest window opened. For example,
if one Firefox window is open with a Power User logged in and another
window is opened with Administrator privileges, both users will now have
Administrator privileges.

Configuring iDRAC6 Enterprise Using the Web Interface

81

Table 5-1.

User Privilege Behavior in Supported Browsers

Browser

Tab Behavior

Window Behavior

Microsoft Internet
Explorer 6

Not applicable

New session

Microsoft Internet
Explorer 7

From latest session opened New session

Firefox 2

From latest session opened From latest session opened

Configuring the iDRAC6 NIC
This section assumes that iDRAC6 has already been configured and is
accessible on the network. See "Configure iDRAC6 Networking" for help with
the initial iDRAC6 network configuration.

Configuring the Network and IPMI LAN Settings
NOTE: You must have Configure iDRAC6 privilege to perform the following steps.
NOTE: Most DHCP servers require a server to store a client identifier token in its
reservations table. The client (iDRAC, for example) must provide this token during
DHCP negotiation. iDRAC6 supplies the client identifier option using a one-byte
interface number (0) followed by a six-byte MAC address.
1 Click System→ Remote Access→ iDRAC.
2 Click the Network/Security tab.
The Network Configuration screen appears.
3 Configure network and IPMI LAN settings as needed. See Table 5-2 and
Table 5-3 for descriptions of the Network Settings and IPMI LAN
Settings options.
4 Click Apply.
5 Click the appropriate button to continue. See Table 5-4.

82

Configuring iDRAC6 Enterprise Using the Web Interface

Table 5-2.

Network Settings

Setting

Description

Enable NIC

When checked, indicates that the NIC is enabled and activates
the remaining controls in this group. When a NIC is disabled,
all communication to and from iDRAC6 via the network is
blocked.
The default is off.

MAC Address

Displays the Media Access Control (MAC) address that
uniquely identifies each node in a network. The MAC address
cannot be changed.

Use DHCP (For
NIC IP Address)

Prompts iDRAC6 to obtain an IP address for the NIC from the
Dynamic Host Configuration Protocol (DHCP) server.
Also deactivates the Static IP Address, Static Subnet Mask, and
Static Gateway controls.
The default is off.

Static IP Address

Allows you to enter or edit a static IP address for the iDRAC6
NIC. To change this setting, deselect the Use DHCP (For NIC
IP Address) checkbox.

Static Subnet Mask Allows you to enter or edit a subnet mask for the iDRAC6 NIC.
To change this setting, first deselect the Use DHCP (For NIC
IP Address) checkbox.
Static Gateway

Allows you to enter or edit a static gateway for the iDRAC6 NIC.
To change this setting, first deselect the Use DHCP (For NIC
IP Address) checkbox.

Use DHCP to
obtain DNS server
addresses

Enable DHCP to obtain DNS server addresses by selecting the
Use DHCP to obtain DNS server addresses checkbox. When
not using DHCP to obtain the DNS server addresses, provide
the IP addresses in the Static Preferred DNS Server and Static
Alternate DNS Server fields.
The default is off.

NOTE: When the Use DHCP to obtain DNS server addresses
checkbox is selected, IP addresses cannot be entered into the
Static Preferred DNS Server and Static Alternate DNS Server
fields.

Configuring iDRAC6 Enterprise Using the Web Interface

83

Table 5-2.

Network Settings (continued)

Setting

Description

Static Preferred
DNS Server

Allows the user to enter or edit a static IP address for the
preferred DNS server. To change this setting, first deselect the
Use DHCP to obtain DNS server addresses checkbox.

Static Alternate
DNS Server

Uses the secondary DNS server IP address when Use DHCP to
obtain DNS server addresses is not selected. Enter an IP address
of 0.0.0.0 if there is no alternate DNS server.

Register iDRAC
on DNS

Registers the iDRAC6 name on the DNS server.

DNS iDRAC
Name

Displays the iDRAC6 name only when Register iDRAC on DNS
is selected. The default name is idrac-service_tag, where
service_tag is the service tag number of the Dell server.
For example: idrac-00002.

Use DHCP for
DNS Domain
Name

Uses the default DNS domain name. When the box is not
selected and the Register iDRAC on DNS option is selected,
modify the DNS domain name in the DNS Domain Name field.

The default is Disabled.

The default is Disabled.

NOTE: To select the Use DHCP for DNS Domain Name checkbox,
also select the Use DHCP (For NIC IP Address) checkbox.
DNS Domain
Name

Table 5-3.

The default DNS Domain Name is blank. When the
Use DHCP for DNS Domain Name checkbox is selected,
this option is grayed out and the field cannot be modified.

IPMI LAN Settings

Setting

Description

Enable IPMI
Over LAN

When checked, indicates that the IPMI LAN channel is enabled.
The default is off.

Channel
Privilege Level
Limit

Configures the maximum privilege level, for the user, that can be
accepted on the LAN channel. Select one of the following options:
Administrator, Operator, or User. The default is Administrator.

Encryption Key Configures the encryption key: 0 to 20 hexadecimal characters
(with no blanks allowed). The default is blank.

84

Configuring iDRAC6 Enterprise Using the Web Interface

Table 5-4.

Network Configuration Buttons

Button

Description

Advanced Settings

Opens the Network Security screen, allowing the user to enter
IP Range, and IP Blocking attributes.

Print

Prints the Network Configuration values that appear on the
screen.

Refresh

Reloads the Network Configuration screen.

Apply

Saves any new settings made to the network configuration
screen.

NOTE: Changes to the NIC IP address settings will close all user
sessions and require users to reconnect to the iDRAC6 Web
interface using the updated IP address settings. All other changes
will require the NIC to be reset, which may cause a brief loss in
connectivity.

Configuring IP Filtering and IP Blocking
NOTE: You must have Configure iDRAC permission to perform the following steps.
1 Click System→ Remote Access→ iDRAC.
2 Click the Network/Security tab.
The Network Configuration screen appears.
3 Click Advanced Settings.
The Network Security screen appears.
4 Configure IP filtering and blocking settings as needed. See Table 5-5 for
descriptions of the IP filtering and blocking settings.
5 Click Apply.
6 Click the appropriate button to continue. See Table 5-6.

Configuring iDRAC6 Enterprise Using the Web Interface

85

Table 5-5.

Network Security Settings

Settings

Description

IP Range Enabled

Enables the IP Range checking feature, which defines a range of
IP addresses that can access iDRAC6. The default is off.

IP Range Address

Determines the acceptable IP subnet address. The default is
192.168.1.0.

IP Range Subnet
Mask

Defines the significant bit positions in the IP address.
The subnet mask should be in the form of a netmask, where the
more significant bits are all 1's with a single transition to all
zeros in the lower-order bits. The default is 255.255.255.0.

IP Blocking
Enabled

Enables the IP address blocking feature, which limits the
number of failed login attempts from a specific IP address for a
preselected time span. The default is off.

IP Blocking Fail
Count

Sets the number of login failures attempted from an IP address
before the login attempts are rejected from that address.
The default is 10.

IP Blocking Fail
Window

Determines the time span in seconds within which IP Block
Fail Count failures must occur to trigger the IP Block Penalty
Time. The default is 3600.

IP Blocking Penalty The time span in seconds that login attempts from an
Time
IP address with excessive failures are rejected. The default
is 3600.

Table 5-6.

Network Security Buttons

Button

Description

Print

Prints the Network Security values that appear on the screen.

Refresh

Reloads the Network Security screen.

Apply

Saves any new settings that you made to the Network
Security screen.

Go Back to
Network Page

Returns to the Network screen.

86

Configuring iDRAC6 Enterprise Using the Web Interface

Configuring Platform Events
Platform event configuration provides a mechanism for configuring iDRAC6
to perform selected actions on certain event messages. The actions include no
action, reboot system, power cycle system, power off system, and generate an
alert (Platform Event Trap [PET] and/or e-mail).
The filterable platform events are listed in Table 5-7.
.

Table 5-7.

Filterable Platform Events

Index

Platform Event

1

Battery Warning Assert

2

Battery Critical Assert

3

Discrete Voltage Critical Assert

4

Temperature Warning Assert

5

Temperature Critical Assert

6

Redundancy Degraded

7

Redundancy Lost

8

Processor Warning Assert

9

Processor Critical Assert

10

Processor Absent Assert

11

Event Log Critical Assert

12

Watchdog Critical Assert

When a platform event occurs (for example, a battery warning assert),
a system event is generated and recorded in the System Event Log (SEL).
If this event matches a platform event filter (PEF) that is enabled and you
have configured the filter to generate an alert (PET or e-mail), then a PET or
e-mail alert is sent to one or more configured destinations.
If the same platform event filter is also configured to perform an action
(such as rebooting the system), the action is performed.

Configuring iDRAC6 Enterprise Using the Web Interface

87

Configuring Platform Event Filters (PEF)
NOTE: Configure platform event filters before you configure the platform event
traps or e-mail alert settings.
1 Log in to the iDRAC6 Web interface.
2 Click System, and then click the Alert Management tab.
The Platform Events screen appears.
3 Select the Generate Alert check box beside each event for which you want
an alert generated.
NOTE: You can enable or disable alert generation for all events by selecting or
deselected the check box next to the Generate Alert column heading.
4 Select the radio button below the action you would like to enable for each
event. You can only select one action for each event.
5 Click Apply.
NOTE: Generate Alert must be enabled for an alert to be sent to any valid,
configured destination (PET or e-mail).

Configuring Platform Event Traps (PET)
NOTE: You must have Configure iDRAC permission to add or enable/disable an
SNMP alert. The following options will not be available if you do not have Configure
iDRAC permission.
1 Log in to the iDRAC6 Web interface.
2 Ensure that you followed the procedures in "Configuring Platform Event
Filters (PEF)."
3 Click System, and then click the Alert Management tab.
The Platform Events screen appears.
4 Click Trap Settings.
The Platform Event Alert Destinations screen appears.
5 Configure your PET destination IP address:
a

Select the Enable check box next to the Destination Number you
would like to activate.

b

Enter an IP address in the Destination IP Address box.
NOTE: The destination community string must be the same as the iDRAC6
community string.

88

Configuring iDRAC6 Enterprise Using the Web Interface

c

Click Apply.
NOTE: To successfully send a trap, configure the Community String value on
the Network Configuration screen. The Community String value indicates the
community string to use in a Simple Network Management Protocol (SNMP)
alert trap sent from iDRAC6. SNMP alert traps are transmitted by iDRAC6
when a platform event occurs. The default setting for the Community String is
Public.

d

To test the configured alert, click Send.

e

To add an additional destination IP address, repeat Step a through
Step d. You may specify up to four destination IP addresses.

Configuring E-Mail Alerts
1 Log in to the iDRAC6 Web interface.
2 Ensure that you followed the procedures in "Configuring Platform Event
Filters (PEF)."
3 Click System, and then click the Alert Management tab.
The Platform Events screen appears.
4 Click Email Alert Settings.
The Email Alert Settings screen appears.
5 Configure your e-mail alert destination.
a

Select the Enabled check box for the first undefined email alert.

b

Enter a valid email address in the Destination Email Address field.

c

Click Apply.
NOTE: To successfully send a test e-mail, the SMTP Server Address must be
configured in the SMTP (e-mail) Server Address Settings section of the Email
Alert Settings screen. The IP address of the SMTP Server communicates with
iDRAC6 to send e-mail alerts when a platform event occurs.

d

Click Send to test the configured e-mail alert (if desired).

e

To add an additional email alert destination, repeat Step a through
Step d. You may specify up to four email alert destinations.

Configuring iDRAC6 Enterprise Using the Web Interface

89

Configuring IPMI Over LAN
1 Log in to the iDRAC6 Web interface.
2 Configure IPMI over LAN:
a

Click System→ Remote Access→ iDRAC, and then click the
Network/Security tab.
The Network Configuration screen appears.

b

Click IPMI LAN Settings.

c

Select the Enable IPMI Over LAN check box.

d

Update the IPMI LAN channel privileges, if required:
NOTE: This setting determines the IPMI commands that can be executed
from the IPMI over LAN interface. For more information, see the IPMI 2.0
specifications.

Under IPMI LAN Settings, click the Channel Privilege Level Limit
drop-down menu, select Administrator, Operator, or User, and then
click Apply.
e

Set the IPMI LAN channel encryption key, if required.
NOTE: The iDRAC6 IPMI supports the RMCP+ protocol.
NOTE: The encryption key must consist of an even number of hexadecimal
characters with a maximum length of 20 characters.

Under IPMI LAN Settings in the Encryption Key field, enter the
encryption key.
f

Click Apply.

3 Configure IPMI Serial over LAN (SOL):
a

Click System→ Remote Access→ iDRAC, and then click the
Network/Security tab.
The Network Configuration screen appears.

90

b

Open the Serial Over LAN screen.

c

Select the Enable Serial Over LAN check box.

Configuring iDRAC6 Enterprise Using the Web Interface

d

Update the IPMI SOL baud rate, if needed, by selecting a data speed
from the Baud Rate drop-down menu.
NOTE: To redirect the serial console over the LAN, ensure that the SOL baud
rate is identical to your managed server’s baud rate.

e

Click Apply.

Adding and Configuring iDRAC6 Users
To manage your system with iDRAC6 and maintain system security, create
unique users with specific administrative permissions (or role-based authority).
To add and configure iDRAC6 users, perform the following steps:
NOTE: You must have Configure iDRAC permission to perform the following steps.
1 Click System→ Remote Access→ iDRAC and then click the Network/
Security tab.
2 Open the Users screen to configure users.
The Users screen displays each user’s User ID, State, Username,
IPMI LAN Privileges, iDRAC Privileges, and Serial Over LAN.
NOTE: User-1 is reserved for the IPMI anonymous user and is not configurable.
3 In the User ID column, click a user ID number.
4 On the User Configuration screen, configure the user’s properties and
privileges.
Table 5-8 describes the General settings for configuring an iDRAC6 user
name and password.
Table 5-9 describes the IPMI LAN Privileges for configuring the user’s
LAN privileges.
Table 5-10 describes the User Group permissions for the IPMI LAN
Privileges and the iDRAC User Privileges settings.
Table 5-11 describes the iDRAC Group permissions. If you add an iDRAC
User Privilege to the Administrator, Power User, or Guest User, the
iDRAC Group will change to the Custom group.
5 When completed, click Apply.
6 Click the appropriate button to continue. See Table 5-12.

Configuring iDRAC6 Enterprise Using the Web Interface

91

Table 5-8.

General Properties

Property

Description

User ID

Contains one of 16 preset User ID numbers. This field
cannot be edited.

Enable User

When checked, indicates that the user’s access to
iDRAC6 is enabled. When unchecked, user access
is disabled.

Username

Specifies an iDRAC6 user name with up to 16 characters.
Each user must have a unique user name.

NOTE: User names on iDRAC6 cannot include the / (forward
slash) or . (period) characters.

NOTE: If the user name is changed, the new name will not
appear in the user interface until the next user login.
Change Password

Enables the New Password and Confirm New Password
fields. When unchecked, the user’s Password cannot be
changed.

New Password

Enables editing the iDRAC6 user’s password. Enter a
Password with up to 20 characters. The characters will
not display.

Confirm New Password

Re-enter the iDRAC6 user’s password to confirm.

Table 5-9.

IPMI LAN User Privileges

Property

Description

Maximum LAN User
Privilege Granted

Specifies the user’s maximum privilege on the IPMI LAN
channel to one of the following user groups: None,
Administrator, Operator, or User.

Enable Serial Over LAN

Allows the user to use IPMI Serial Over LAN.
When checked, this privilege is enabled.

92

Configuring iDRAC6 Enterprise Using the Web Interface

Table 5-10.

iDRAC6 User Privileges

Property

Description

iDRAC Group

Specifies the user’s maximum iDRAC6 user privilege as
one of the following: Administrator, Power User, Guest
User, Custom, or None.
See Table 5-11 for iDRAC6 Group permissions.

Login to iDRAC

Enables the user to log in to iDRAC6.

Configure iDRAC

Enables the user to configure iDRAC6.

Configure Users

Enables the user to allow specific users to access the
system.

Clear Logs

Enables the user to clear the iDRAC6 logs.

Execute Server Control
Commands

Enables the user to execute RACADM commands.

Access Console
Redirection

Enables the user to run Console Redirection.

Access Virtual Media

Enables the user to run and use Virtual Media.

Test Alerts

Enables the user to send test alerts (e-mail and PET) to a
specific user.

Execute Diagnostic
Commands

Enables the user to run diagnostic commands.

Table 5-11.

iDRAC6 Group Permissions

User Group

Permissions Granted

Administrator

Login to iDRAC, Configure iDRAC, Configure Users, Clear
Logs, Execute Server Control Commands, Access Console
Redirection, Access Virtual Media, Test Alerts, Execute
Diagnostic Commands

Power User

Login to iDRAC, Clear Logs, Execute Server Control
Commands, Access Console Redirection, Access Virtual
Media, Test Alerts

Guest User

Login to iDRAC

Configuring iDRAC6 Enterprise Using the Web Interface

93

Table 5-11. iDRAC6 Group Permissions (continued)
User Group

Permissions Granted

Custom

Selects any combination of the following permissions: Login to
iDRAC, Configure iDRAC, Configure Users, Clear Logs,
Execute Server Action Commands, Access Console
Redirection, Access Virtual Media, Test Alerts, Execute
Diagnostic Commands

None

No assigned permissions

Table 5-12. User Configuration Buttons
Button

Action

Print

Prints the User Configuration values that appear on the
screen.

Refresh

Reloads the User Configuration screen.

Apply

Saves any new settings made to the user configuration.

Go Back To Users
screen

Returns to the Users screen.

Securing iDRAC6 Communications Using SSL and
Digital Certificates
This section provides information about the following data security features
that are incorporated in iDRAC6:

94

•

Secure Sockets Layer (SSL)

•

Certificate Signing Request (CSR)

•

Accessing the SSL main menu

•

Generating a new CSR

•

Uploading a server certificate

•

Viewing a server certificate

Configuring iDRAC6 Enterprise Using the Web Interface

Secure Sockets Layer (SSL)
iDRAC6 includes a Web server that is configured to use the industry-standard
SSL security protocol to transfer encrypted data over a network. Built upon
public-key and private-key encryption technology, SSL is a widely accepted
technology for providing authenticated and encrypted communication
between clients and servers to prevent eavesdropping across a network.
An SSL-enabled system can perform the following tasks:
•

Authenticate itself to an SSL-enabled client

•

Allow the client to authenticate itself to the server

•

Allow both systems to establish an encrypted connection

The encryption process provides a high level of data protection. iDRAC6
employs the 128-bit SSL encryption standard, the most secure form of
encryption generally available for Internet browsers in North America.
The iDRAC6 Web server has a Dell self-signed SSL digital certificate
(Server ID) by default. To ensure high security over the Internet, replace the
Web server SSL certificate with a certificate signed by a well-known
certificate authority. To initiate the process of obtaining a signed certificate,
you can use the iDRAC6 Web interface to generate a Certificate Signing
Request (CSR) with your company’s information. You can then submit the
generated CSR to a CA such as VeriSign or Thawte.

Certificate Signing Request (CSR)
A CSR is a digital request to a Certificate Authority (CA) for a secure server
certificate. Secure server certificates allow clients of the server to trust the
identity of the server they have connected to and to negotiate an encrypted
session with the server.
A Certificate Authority is a business entity that is recognized in the
IT industry for meeting high standards of reliable screening, identification,
and other important security criteria. Examples of CAs include Thawte and
VeriSign. After the CA receives a CSR, they review and verify the information
the CSR contains. If the applicant meets the CA’s security standards, the
CA issues a digitally-signed certificate that uniquely identifies that applicant
for transactions over networks and on the Internet.

Configuring iDRAC6 Enterprise Using the Web Interface

95

After the CA approves the CSR and sends the certificate, upload the
certificate to the iDRAC6 firmware. The CSR information stored on iDRAC6
firmware must match the information contained in the certificate.

Accessing the SSL Main Menu
1 Click System→ Remote Access→ iDRAC, then click the Network/
Security tab.
2 Click SSL to open the SSL Main Menu screen.
Use the SSL Main Menu screen to generate a CSR to send to a CA. The CSR
information is stored on the iDRAC6 firmware.
Table 5-13 describes the options available when generating a CSR.
Table 5-14 describes the available buttons on the SSL Main Menu screen.
Table 5-13. SSL Main Menu Options
Field

Description

Generate a New
Certificate Signing
Request (CSR)

Select the option and click Next to open the Generate
Certificate Signing Request (CSR) screen.

NOTE: Each new CSR overwrites any previous CSR on the
firmware. For a CA to accept your CSR, the CSR in the
firmware must match the certificate returned from the CA.

Upload Server
Certificate

Select the option and click Next to open the Certificate
Upload screen and upload the certificate sent to you by
the CA.

NOTE: Only X509, Base 64-encoded certificates are accepted
by iDRAC6. DER-encoded certificates are not accepted.
View Server Certificate Select the option and click Next to open the View Server
Certificate screen and view an existing server certificate.

96

Configuring iDRAC6 Enterprise Using the Web Interface

Table 5-14.

SSL Main Menu Buttons

Button

Description

Print

Prints the SSL Main Menu values that appear on
the screen.

Refresh

Reloads the SSL Main Menu screen.

Next

Processes the information on the SSL Main Menu screen
and continues to the next step.

Generating a New Certificate Signing Request
NOTE: Each new CSR overwrites any previous CSR data stored in the firmware.
The CSR in the firmware must match the certificate returned from the CA.
Otherwise, iDRAC6 will not accept the certificate.
1 On the SSL Main Menu screen, select Generate a New Certificate
Signing Request (CSR) and click Next.
2 On the Generate Certificate Signing Request (CSR) screen, enter a value
for each CSR attribute.
Table 5-15 describes the Generate Certificate Signing Request (CSR)
screen options.
3 Click Generate to create the CSR.
4 Click Download to save the CSR file to your local computer.
5 Click the appropriate button to continue. See Table 5-16.
Table 5-15.

Generate Certificate Signing Request (CSR) Options

Field

Description

Common Name

The exact name being certified (usually the Web server's
domain name, for example, www.xyzcompany.com).
Only alphanumeric characters, hyphens, underscores,
and periods are valid. Spaces are not valid.

Organization Name

The name associated with this organization (for example,
XYZ Corporation). Only alphanumeric characters,
hyphens, underscores, periods and spaces are valid.

Configuring iDRAC6 Enterprise Using the Web Interface

97

Table 5-15. Generate Certificate Signing Request (CSR) Options (continued)
Field

Description

Organization Unit

The name associated with an organizational unit, such as a
department (for example, Information Technology).
Only alphanumeric characters, hyphens, underscores,
periods, and spaces are valid.

Locality

The city or other location of the entity being certified
(for example, Round Rock). Only alphanumeric characters
and spaces are valid. Do not separate words using an
underscore or other character.

State Name

The state or province where the entity who is applying
for a certification is located (for example, Texas).
Only alphanumeric characters and spaces are valid. Do not
use abbreviations.

Country Code

The name of the country where the entity applying for
certification is located.

Email

The e-mail address associated with the CSR. Enter the
company’s e-mail address, or any e-mail address associated
with the CSR. This field is optional.

Uploading a Server Certificate
Table 5-16. Generate Certificate Signing Request (CSR) Buttons
Button

Description

Print

Prints the Generate Certificate Signing Request values
that appear on the screen.

Refresh

Reloads the Generate Certificate Signing Request screen.

Generate

Generates a CSR and then prompts the user to save it to a
specified directory.

Download

Downloads the certificate to the local computer.

Go Back to SSL Main
Menu

Returns the user to the SSL Main Menu screen.

98

Configuring iDRAC6 Enterprise Using the Web Interface

1 In the SSL Main Menu screen, select Upload Server Certificate and click
Next.
The Certificate Upload screen appears.
2 In the File Path field, enter the path to the certificate or click Browse to
navigate to the certificate file.
NOTE: The File Path value displays the file path of the certificate you are uploading.
You must enter the file path, which includes the full path and the complete file name
and file extension.
3 Click Apply.
4 Click the appropriate button to continue. See Table 5-17.
Table 5-17.

Certificate Upload Buttons

Button

Description

Print

Prints the values that appear on the Certificate Upload screen

Refresh

Reloads the Certificate Upload screen

Apply

Applies the certificate to iDRAC6 firmware

Go Back to SSL Main Returns the user to the SSL Main Menu screen
Menu

Viewing a Server Certificate
1 On the SSL Main Menu screen, select View Server Certificate and click Next.
Table 5-18 describes the fields and associated descriptions listed in the
Certificate window.
2 Click the appropriate button to continue. See Table 5-19.
Table 5-18.

Certificate Information

Field

Description

Serial Number

Certificate serial number

Subject Information

Certificate attributes entered by the subject

Issuer Information

Certificate attributes returned by the issuer

Valid From

Issue date of the certificate

Valid To

Expiration date of the certificate
Configuring iDRAC6 Enterprise Using the Web Interface

99

Table 5-19. View Server Certificate Buttons
Button

Description

Print

Prints the View Server Certificate values that appear
on the screen.

Refresh

Reloads the View Server Certificate screen.

Go Back to SSL Main Menu

Return to the SSL Main Menu screen.

Configuring and Managing Active Directory
Certificates
NOTE: You must have Configure iDRAC permission to configure Active Directory
and upload, download, and view an Active Directory certificate.
NOTE: For more information about Active Directory configuration and how to
configure Active Directory with the standard schema or an extended schema,
see "Using iDRAC6 With Microsoft Active Directory."
To access the Active Directory Main Menu:
1 Click System→ Remote Access→ iDRAC, and then click the Network/
Security tab.
2 Click Active Directory to open the Active Directory Main Menu screen.
Table 5-20 lists the Active Directory Main Menu options.
3 Click the appropriate button to continue. See Table 5-20.
Table 5-20. Active Directory Main Menu Options
Field

Description

Configure Active
Directory

Configures the Active Directory ROOT Domain Name,
Active Directory Authentication Timeout, Active Directory
Schema Selection, iDRAC Name, iDRAC Domain Name,
Role Groups, Group Name, and Group Domain settings.

Upload Active
Directory CA
Certificate

Uploads an Active Directory certificate to iDRAC6.

View Active Directory
CA Certificate

Displays an Active Directory Certificate that has been
uploaded to iDRAC6.

100

Configuring iDRAC6 Enterprise Using the Web Interface

Table 5-21.

Active Directory Main Menu Buttons

Button

Definition

Print

Prints the Active Directory Main Menu values that appear
on the screen.

Refresh

Reloads the Active Directory Main Menu screen.

Next

Processes the information on the Active Directory Main
Menu screen and continues to the next step.

Configuring Active Directory (Standard Schema and Extended Schema)
1 On the Active Directory Main Menu screen, select Configure Active
Directory and click Next.
2 On the Active Directory Configuration screen, enter the Active
Directory settings.
Table 5-22 describes the Active Directory Configuration and
Management settings.
3 Click Apply to save the settings.
4 Click the appropriate button to continue. See Table 5-23.
5 To configure the Role Groups for Active Directory Standard Schema,
click on the individual Role Group (1-5). See Table 5-24 and Table 5-25.
NOTE: To save the settings on the Active Directory Configuration screen,
click Apply before proceeding to the Custom Role Group screen.
Table 5-22.

Active Directory Configuration Settings

Setting

Description

Enable Active
Directory

When checked, enables Active Directory. The default is
disabled.

ROOT Domain Name The Active Directory ROOT domain name. This default
is blank.
The name must be a valid domain name consisting of x.y,
where x is a 1-254 character ASCII string with no spaces
between characters, and y is a valid domain type such as
com, edu, gov, int, mil, net, or org. The default is blank.

Configuring iDRAC6 Enterprise Using the Web Interface

101

Table 5-22. Active Directory Configuration Settings (continued)
Setting

Description

Timeout

The time, in seconds, to wait for Active Directory queries to
complete. Minimum value is equal to or greater than
15 seconds. The default value is 120.

Use Standard Schema

Uses standard schema with Active Directory.

Use Extended Schema Uses the extended schema with Active Directory.
iDRAC Name

The name that uniquely identifies iDRAC6 in Active
Directory. This default is blank.
The name must be a 1-254 character ASCII string with no
spaces between characters.

iDRAC Domain Name The DNS name of the domain, where the Active Directory
iDRAC6 object resides. This default is blank.
The name must be a valid domain name consisting of x.y,
where x is a 1-254 character ASCII string with no spaces
between characters, and y is a valid domain type such as
com, edu, gov, int, mil, net, or org.
Role Groups

The list of role groups associated with iDRAC6.
To change the settings for a role group, click their role group
number, in the role groups list.

Group Name

The name that identifies the role group in the Active
Directory associated with iDRAC6. This default is blank.

Group Domain

The domain type where the Role Group resides.

Table 5-23. Active Directory Configuration Buttons
Button

Description

Print

Prints the Active Directory Configuration values that
appear on the screen.

Refresh

Reloads the Active Directory Configuration screen.

Apply

Saves any new settings made to the Active Directory
Configuration screen.

Go Back to Active
Returns to the Active Directory Main Menu screen.
Directory Main Menu

102

Configuring iDRAC6 Enterprise Using the Web Interface

Table 5-24.

Role Group Privileges

Setting

Description

Role Group Privilege Level

Specifies the user’s maximum iDRAC6 user
privilege as one of the following:
Administrator, Power User, Guest User, None,
or Custom.
See Table 5-25 for Role Group permissions.

Login to iDRAC

Allows the group log in access to iDRAC6.

Configure iDRAC

Allows the group permission to configure
iDRAC6.

Configure Users

Allows the group permission to configure
users.

Clear Logs

Allows the group permission to clear logs.

Execute Server Control Commands Allows the group permission to execute server
control commands.
Access Console Redirection

Allows the group access to Console
Redirection.

Access Virtual Media

Allows the group access to Virtual Media.

Test Alerts

Allows the group to send test alerts (e-mail and
PET) to a specific user.

Execute Diagnostic Commands

Allows the group permission to execute
diagnostic commands.

Table 5-25.

Role Group Permissions

Property

Description

Administrator

Login to iDRAC, Configure iDRAC,
Configure Users, Clear Logs, Execute Server
Control Commands, Access Console
Redirection, Access Virtual Media,
Test Alerts, Execute Diagnostic Commands

Power User

Login to iDRAC, Clear Logs, Execute Server
Control Commands, Access Console
Redirection, Access Virtual Media, Test Alerts

Configuring iDRAC6 Enterprise Using the Web Interface

103

Table 5-25. Role Group Permissions (continued)
Property

Description

Guest User

Login to iDRAC

Custom

Selects any combination of the following
permissions: Login to iDRAC, Configure
iDRAC, Configure Users, Clear Logs, Execute
Server Action Commands, Access Console
Redirection, Access Virtual Media, Test
Alerts, Execute Diagnostic Commands

None

No assigned permissions

Uploading an Active Directory CA Certificate
1 On the Active Directory Main Menu screen, select Upload Active
Directory CA Certificate and click Next.
2 On the Certificate Upload screen, enter the file path of the certificate in
the File Path field, or click Browse to navigate to the certificate file.
NOTE: The File Path value displays the file path of the certificate you are uploading.
You must enter the file path, which includes the full path and the complete file name
and file extension.
Ensure that the domain controller’s SSL certificates have been signed by the
same Certificate Authority and that this Certificate is available on the
management station accessing iDRAC6.
3 Click Apply.
4 Click the appropriate button to continue. See Table 5-26.
Table 5-26. Certificate Upload Buttons
Button

Description

Print

Prints the Certificate Upload values that appear on
the screen

Refresh

Reloads the Certificate Upload screen

Apply

Applies the certificate to iDRAC6 firmware

Go Back to Active
Returns to the Active Directory Main Menu screen
Directory Main Menu

104

Configuring iDRAC6 Enterprise Using the Web Interface

Viewing an Active Directory CA Certificate
Use the Active Directory Main Menu screen to view a CA server certificate
for iDRAC6.
1 On the Active Directory Main Menu screen, select View Active Directory
CA Certificate and click Next.
Table 5-27 describes the fields and associated descriptions listed in the
Certificate window.
2 Click the appropriate button to continue. See Table 5-28.
Table 5-27.

Active Directory CA Certificate Information

Field

Description

Serial Number

Certificate serial number.

Subject Information

Certificate attributes entered by the subject.

Issuer Information

Certificate attributes returned by the issuer.

Valid From

Certificate issue date.

Valid To

Certificate expiration date.

Table 5-28.

View Active Directory CA Certificate Buttons

Button

Description

Print

Prints the Active Directory CA Certificate values that
appear on the screen.

Refresh

Reloads the Active Directory CA Certificate screen.

Go Back to Active
Returns the user to the Active Directory Main Menu
Directory Main Menu screen.

Enabling or Disabling Local Configuration Access
NOTE: The default setting for local configuration access is Enabled.

Enabling Local Configuration Access
1 Click System→ Remote Access→ iDRAC→ Network/Security.
2 Under Local Configuration, click to uncheck Disable iDRAC local USER
Configuration Updates to enable access.
Configuring iDRAC6 Enterprise Using the Web Interface

105

3 Click Apply.
4 Click the appropriate button to continue. See Table 5-34.

Disabling Local Configuration Access
1 Click System→ Remote Access→ iDRAC→ Network/Security.
2 Under Local Configuration, click to check Disable iDRAC local USER
Configuration Updates to disable access.
3 Click Apply.
4 Click the appropriate button to continue. See Table 5-34.

Configuring iDRAC6 Services
NOTE: To modify these settings, you must have Configure iDRAC permission.
NOTE: When you apply changes to services, the changes take effect immediately.
Existing connections may be terminated without warning.
NOTE: There is a known issue with the Telnet client supplied with Microsoft
Windows communicating with a BMU. Use another Telnet client such as
HyperTerminal or PuTTY.
1 Click System→ Remote Access→ iDRAC, and then click the Network/
Security tab.
2 Click Services to open the Services configuration screen.
3 Configure the following services, as required:
•

Web server — see Table 5-29 for Web server settings

•

SSH — see Table 5-30 for SSH settings

•

Telnet — see Table 5-31 for telnet settings

•

SNMP Agent — see Table 5-32 for SNMP Agent settings

•

Automated System Recovery Agent — see Table 5-33 for Automated
System Recovery Agent settings

4 Click Apply.
5 Click the appropriate button to continue. See Table 5-34.

106

Configuring iDRAC6 Enterprise Using the Web Interface

Table 5-29.

Web Server Settings

Setting

Description

Enabled

Enables or disables the iDRAC6 Web server.
When checked, indicates that the Web server is enabled.
The default value is enabled.

Max Sessions

The maximum number of simultaneous sessions allowed
for this system. This field is not editable. There can be four
simultaneous sessions.

Current Sessions

The number of current sessions on the system, less than or
equal to the Max Sessions. This field is not editable.

Timeout

The time, in seconds, that a connection is allowed to
remain idle. The session is cancelled when the timeout is
reached. Changes to the timeout setting take affect
immediately and will reset the Web server. Timeout range is
60 to 10800 seconds. The default is 1800 seconds.

HTTP Port Number

The port on which iDRAC6 listens for a browser
connection. The default is 80.

HTTPS Port Number

The port on which iDRAC6 listens for a secure browser
connection. The default is 443.

Table 5-30.

SSH Settings

Setting

Description

Enabled

Enables or disables SSH. When checked, the checkbox
indicates that SSH is enabled.

Max Sessions

The maximum number of simultaneous sessions allowed
for this system. Only one session is supported.

Active Sessions

The number of current sessions on the system.

Timeout

The secure shell idle timeout, in seconds. Timeout range is
60 to 10800 seconds. Enter 0 seconds to disable the
Timeout feature. The default is 1800.

Port Number

The port on which iDRAC6 listens for an SSH connection.
The default is 22.

Configuring iDRAC6 Enterprise Using the Web Interface

107

Table 5-31. Telnet Settings
Setting

Description

Enabled

Enables or disables telnet. When checked, telnet is
enabled. The default value is disabled.

Max Sessions

The maximum number of simultaneous sessions allowed
for this system. Only one session is supported.

Active Sessions

The number of current sessions on the system.

Timeout

The telnet idle timeout, in seconds. Timeout range is 60 to
10800 seconds. Enter 0 seconds to disable the Timeout
feature. The default is 1800.

Port Number

The port on which iDRAC6 listens for a telnet connection.
The default is 23.

Table 5-32. SNMP Agent
Setting

Description

Enabled

Enables or disables email alerts.

SNMP Community
Name

The name of the community that contains the IP address
for the SNMP Alert destination. The Community Name
may be up to 31 non-blank characters in length.
Default=public.

Table 5-33. Automated System Recovery Agent Setting
Setting

Description

Enabled

Enables the Automated System Recovery Agent.

Table 5-34. Services Buttons
Button

Description

Print

Prints the Services screen.

Refresh

Refreshes the Services screen.

Apply Changes

Applies the Services screen settings.

108

Configuring iDRAC6 Enterprise Using the Web Interface

Updating iDRAC6 Firmware
NOTE: If iDRAC6 firmware becomes corrupted, as could occur if the iDRAC6
firmware update progress is interrupted before it completes, you can recover
iDRAC6 using the CMC. See your CMC Firmware User Guide for instructions.
NOTE: The firmware update, by default, retains the current iDRAC6 settings.
During the update process, you have the option to reset iDRAC6 configuration to the
factory defaults. If you set the configuration to the factory defaults external network
access will be disabled when the update completes. You must enable and configure
the network using the iDRAC6 Configuration Utility or the CMC Web interface.
1 Start the iDRAC6 Web interface.
2 Click System→ Remote Access→ iDRAC, then click the Update tab.
NOTE: To update the firmware, iDRAC6 must be placed in an update mode.
Once in this mode, iDRAC6 will automatically reset, even if you cancel the
update process.

3 On the Firmware Update screen, click Next to start the update process.
4 In the Firmware Update - Upload (page 1 of 4) window, click Browse,
or enter the path to the firmware image that you downloaded.
For example:
C:\Updates\V2.0\.
The default firmware image name is firmimg.imc.
5 Click Next.
•

The file will be uploaded to iDRAC6. This may take several minutes
to complete.
OR

•

You can click Cancel at this time, if you would like to end the
firmware upgrade process. Clicking Cancel will reset iDRAC6 to
normal operating mode.

Configuring iDRAC6 Enterprise Using the Web Interface

109

6 In the Firmware Update - Validation (page 2 of 4) window, you will see
the results of the validation performed on the image file you uploaded.
•

If the image file uploaded successfully and passed all verification
checks, a message will appear indicating that the firmware image has
been verified.
OR

•

If the image did not upload successfully, or it did not pass the
verification checks, the firmware update will return to the Firmware
Update - Upload (page 1 of 4) window. You can attempt to upgrade
iDRAC6 again or click Cancel to reset iDRAC6 to normal operating
mode.

NOTE: If you deselect the Preserve Configuration checkbox, iDRAC6 will be reset
to its default settings. In the default settings, the LAN is disabled. You will not be
able to log in to the iDRAC6 Web interface. You will have to reconfigure the LAN
settings using the CMC Web interface or iKVM using the iDRAC6 Configuration
Utility during BIOS POST.
7 By default the Preserve Configuration checkbox is checked, to preserve
the current settings on iDRAC6 after an upgrade. If you do not want the
settings to be preserved, deselect the Preserve Configuration checkbox.
8 Click Begin Update to start the upgrade process. Do not interrupt the
upgrade process.
9 In the Firmware Update - Updating (page 3 of 4) window, you will see the
status of the upgrade. The progress of the firmware upgrade operation,
measured in percentages, will appear in the Progress column.
10 Once the firmware update is complete, the Firmware Update - Update
Results (page 4 of 4) window will appear and iDRAC6 will reset
automatically. You must close the current browser window and reconnect
to iDRAC6 using a new browser window.

110

Configuring iDRAC6 Enterprise Using the Web Interface

Updating iDRAC6 Firmware Using the CMC
Typically, iDRAC6 firmware is updated using iDRAC6 utilities, such as the
iDRAC6 Web interface or operating system specific update packages
downloaded from support.dell.com.
You can use the CMC Web interface or CMC RACADM to update the
iDRAC6 firmware. This feature is available both when iDRAC6 firmware is in
Normal mode, as well as when it is corrupted. See "Updating iDRAC6
Firmware Using the CMC."]
NOTE: See the Chassis Management Controller Firmware User Guide for
instructions for using the CMC Web interface.
To update iDRAC6 firmware, perform the following steps:
1 Download the latest iDRAC6 firmware to your management computer
from support.dell.com.
2 Log in to the CMC Web-based interface.
3 Click Chassis in the system tree.
4 Click the Update tab. The Updatable Components screen appears.
5 Click server-n, where n is the number of the server whose iDRAC6 you
want to update.
6 Click Browse, navigate to the iDRAC6 firmware image you downloaded,
and then click Open.
7 Click Begin Firmware Update.
After the firmware image file has been uploaded to the CMC, iDRAC6 will
update itself with the image.

Configuring iDRAC6 Enterprise Using the Web Interface

111

112

Configuring iDRAC6 Enterprise Using the Web Interface

Using iDRAC6 With Microsoft
Active Directory
A directory service maintains a common database of all information needed for
controlling users, computers, printers, etc. on a network. If your company already
uses the Microsoft® Active Directory® service software, you can configure the
software to provide access to iDRAC6, allowing you to add and control iDRAC6
user privileges to your existing users in your Active Directory software.
NOTE: Using Active Directory to recognize iDRAC6 users is supported on the
Microsoft Windows 2000, Windows Server 2003, and Windows Server 2008
operating systems.
Table 6-1 shows the nine iDRAC6 Active Directory user privileges.
Table 6-1.

iDRAC6 User Privileges

Privilege

Description

Login to iDRAC

Enables the user to log in to iDRAC6

Configure iDRAC

Enables the user to configure iDRAC6

Configure Users

Enables the user to allow specific users to access
the system

Clear Logs

Enables the user to clear the iDRAC6 logs

Execute Server Control
Commands

Enables the user to execute RACADM commands

Access Console Redirection

Enables the user to run Console Redirection

Access Virtual Media

Enables the user to run and use Virtual Media

Test Alerts

Enables the user to send test alerts (e-mail and PET)
to a specific user

Execute Diagnostic Commands Enables the user to run diagnostic commands

Using iDRAC6 With Microsoft Active Directory

113

Prerequisites for Enabling Active Directory
Authentication for iDRAC6
To use the Active Directory authentication feature of iDRAC6, you must
have already deployed an Active Directory infrastructure. See the Microsoft
website for information on how to set up an Active Directory infrastructure,
if you don't already have one.
iDRAC6 uses the standard Public Key Infrastructure (PKI) mechanism to
authenticate securely into the Active Directory; therefore, you would also
require an integrated PKI into the Active Directory infrastructure.
See the Microsoft website for more information on the PKI setup.
To correctly authenticate to all the domain controllers, you also need to enable
the Secure Socket Layer (SSL) on all domain controllers that iDRAC6 connects
to. See "Enabling SSL on a Domain Controller" for more specific information.

Supported Active Directory Authentication
Mechanisms
You can use Active Directory to define user access on iDRAC6 through two
methods: you can use the extended schema solution, which Dell has
customized to add Dell-defined Active Directory objects. Or, you can use the
standard schema solution, which uses Active Directory group objects only.
See the sections that follow for more information about these solutions.
When using Active Directory to configure access to iDRAC6, you must
choose either the extended schema or the standard schema solution.
The advantages of using the extended schema solution are:
•

All of the access control objects are maintained in Active Directory.

•

Maximum flexibility is provided in configuring user access on different
iDRAC6 cards with varying privilege levels.

The advantage of using the standard schema solution is that no schema
extension is required because all of the necessary object classes are provided
by Microsoft’s default configuration of the Active Directory schema.

114

Using iDRAC6 With Microsoft Active Directory

Extended Schema Active Directory Overview
Using the extended schema solution requires the Active Directory schema
extension, as described in the following section.

Extending the Active Directory Schema
Important: The schema extension for this product is different from the previous
generations of Dell Remote Management products. You must extend the new
schema and install the new Active Directory Users and Computers Microsoft
Management Console (MMC) Snap-in on your directory. The old schema
does not work with this product.
NOTE: Extending the new schema or installing the new extension to Active Directory
User and Computer Snap-in has no impact on previous versions of the product.
The schema extender and Active Directory Users and Computers MMC
Snap-in extension are available on the Dell Systems Management Tools and
Documentation DVD. For more information, see "Extending the Active
Directory Schema" and "Installing the Dell Extension to the Active Directory
Users and Computers Snap-In." For further details on extending the schema
for iDRAC6 and installing the Active Directory Users and Computers MMC
Snap-in, see the Dell OpenManage Installation and Security User’s Guide
available on support.dell.com\manuals.
NOTE: When you create iDRAC6 Association Objects or iDRAC6 Device Objects,
be certain to select Dell Remote Management Object Advanced.

Active Directory Schema Extensions
The Active Directory data is a distributed database of Attributes and Classes.
The Active Directory schema includes the rules that determine the type of
data that can be added or included in the database. The user class is one
example of a Class that is stored in the database. Some example user class
attributes can include the user’s first name, last name, phone number, and so
on. Companies can extend the Active Directory database by adding their own
unique Attributes and Classes to solve environment-specific needs. Dell has
extended the schema to include the necessary changes to support remote
management Authentication and Authorization.
Each Attribute or Class that is added to an existing Active Directory Schema
must be defined with a unique ID. To maintain unique IDs across the
industry, Microsoft maintains a database of Active Directory Object
Using iDRAC6 With Microsoft Active Directory

115

Identifiers (OIDs) so that when companies add extensions to the schema,
they can be guaranteed to be unique and not to conflict with each other.
To extend the schema in Microsoft's Active Directory, Dell received unique
OIDs, unique name extensions, and uniquely linked attribute IDs for our
attributes and classes that are added into the directory service.
•

Dell extension is: dell

•

Dell base OID is: 1.2.840.113556.1.8000.1280

•

RAC LinkID range is: 12070 to 12079

Overview of the iDRAC6 Schema Extensions
To provide the greatest flexibility in the multitude of customer environments,
Dell provides a group of properties that can be configured by the user
depending on the desired results. Dell has extended the schema to include an
Association, Device, and Privilege property. The Association property is used
to link together the users or groups with a specific set of privileges to one or
more iDRAC6 devices. This model provides an Administrator maximum
flexibility over the different combinations of users, iDRAC6 privileges, and
iDRAC6 devices on the network without adding too much complexity.

Active Directory Object Overview
For each physical iDRAC6 device on the network that you want to integrate
with Active Directory for Authentication and Authorization, create at least
one Association Object and one iDRAC6 Device Object. You can create
multiple Association Objects, and each Association Object can be linked to as
many users, groups of users, or iDRAC6 Device Objects as required. The users
and iDRAC6 user groups can be members of any domain in the enterprise.
However, each Association Object can be linked (or, may link users, groups
of users, or iDRAC6 Device Objects) to only one Privilege Object.
This example allows an Administrator to control each user’s privileges on
specific iDRAC6 devices.
The iDRAC6 Device object is the link to the iDRAC6 firmware for querying
Active Directory for authentication and authorization. When iDRAC6 is added
to the network, the Administrator must configure iDRAC6 and its device
object with its Active Directory name so users can perform authentication and
authorization with Active Directory. Additionally, the Administrator must add
iDRAC6 to at least one Association Object in order for users to authenticate.
116

Using iDRAC6 With Microsoft Active Directory

Figure 6-1 illustrates that the Association Object provides the connection
that is needed for all of the Authentication and Authorization.
Figure 6-1. Typical Setup for Active Directory Objects

iDRAC
Association Object

User(s)
Group(s)

Privilege Object

iDRAC
Device Object(s)

You can create as many or as few association objects as required. However,
you must create at least one Association Object, and you must have one
iDRAC6 Device Object for each iDRAC6 device on the network that you
want to integrate with Active Directory for Authentication and Authorization
with iDRAC6.
The Association Object allows for as many or as few users and/or groups as
well as iDRAC6 Device Objects. However, the Association Object only
includes one Privilege Object per Association Object. The Association Object
connects the Users who have Privileges on the iDRAC6 devices.
The Dell extension to the ADUC MMC Snap-in only allows associating the
Privilege Object and iDRAC6 Objects from the same domain with the
Association Object. The Dell extension does not allow a group or an iDRAC6
object from other domains to be added as a product member of the
Association Object.
Users, user groups, or nested user groups from any domain can be added into
the Association Object. Extended Schema solutions support any user group
type and any user group nesting across multiple domains allowed by
Microsoft Active Directory.

Using iDRAC6 With Microsoft Active Directory

117

Accumulating Privileges Using Extended Schema
The Extended Schema Authentication mechanism supports Privilege
Accumulation from different privilege objects associated with the same user
through different Association Objects. In other words, Extended Schema
Authentication accumulates privileges to allow the user the super set of all
assigned privileges corresponding to the different privilege objects associated
with the same user.
Figure 6-2 provides an example of accumulating privileges using Extended
Schema.
Figure 6-2. Privilege Accumulation for a User
Domain 1

Domain 2
A01

Group1

User1

User2

A02

Priv1

Priv2

iDRAC1

iDRAC2

The figure shows two Association Objects—A01 and A02. User1 is associated
to iDRAC2 through both association objects. Therefore, User1 has
accumulated privileges that are the result of combining the privileges set for
objects Priv1 and Priv2 on iDRAC2.
For example, Priv1 has these privileges: Login, Virtual Media, and Clear Logs
and Priv2 has these privileges: Login to iDRAC, Configure iDRAC, and Test
Alerts. As a result, User1 now has the privilege set: Login to iDRAC,
Virtual Media, Clear Logs, Configure iDRAC, and Test Alerts, which is the
combined privilege set of Priv1 and Priv2.
118

Using iDRAC6 With Microsoft Active Directory

Extended Schema Authentication accumulates privileges to allow the user
the maximum set of privileges possible considering the assigned privileges of
the different privilege objects associated to the same user.
In this configuration, User1 has both Priv1 and Priv2 privileges on iDRAC2.
User1 has Priv1 privileges on iDRAC1 only. User2 has Priv1 privileges on both
iDRAC1 and iDRAC2. In addition, this figure shows that User1 can be in a
different domain and can be a member of a group.

Configuring Extended Schema Active Directory to Access iDRAC6
Before using Active Directory to access iDRAC6, configure the Active
Directory software and iDRAC6 by performing the following steps in order:
1 Extend the Active Directory schema (see "Extending the Active Directory
Schema").
2 Extend the Active Directory Users and Computers Snap-in (see "Installing
the Dell Extension to the Active Directory Users and Computers Snap-In").
3 Add iDRAC6 users and their privileges to Active Directory (see "Adding
iDRAC6 Users and Privileges to Active Directory").
4 Enable SSL on each of your domain controllers (see "Enabling SSL on a
Domain Controller").
5 Configure iDRAC6 Active Directory properties using either the iDRAC6
Web-based interface or the RACADM (see "Configuring Active Directory
With Extended Schema Using the iDRAC6 Web-Based Interface" or
"Configuring Active Directory With Extended Schema Using RACADM").
Extending your Active Directory schema adds a Dell organizational unit,
schema classes and attributes, and example privileges and association objects
to the Active Directory schema. Before you extend the schema, ensure that
you have Schema Admin privileges on the Schema Master Flexible Single
Master Operation (FSMO) Role Owner of the domain forest.
You can extend your schema using one of the following methods:
•

Dell Schema Extender utility

•

LDIF script file

If you use the LDIF script file, the Dell organizational unit will not be added
to the schema.

Using iDRAC6 With Microsoft Active Directory

119

The LDIF files and Dell Schema Extender are located on your Dell Systems
Management Tools and Documentation DVD in the following respective
directories:
•

DVD drive:\SYSMGMT\ManagementStation\support\OMActiveDirectory_
Tools\Remote_Management_Advanced\LDIF_Files

•

:\SYSMGMT\ManagementStation\support\OMActiveDirecto
ry_Tools\Remote_Management_Advanced\Schema Extender

To use the LDIF files, see the instructions in the readme included in the
LDIF_Files directory. To use the Dell Schema Extender to extend the Active
Directory Schema, see "Using the Dell Schema Extender."
You can copy and run the Schema Extender or LDIF files from any location.
Using the Dell Schema Extender

CAUTION: The Dell Schema Extender uses the SchemaExtenderOem.ini file.
To ensure that the Dell Schema Extender utility functions properly, do not modify
the name of this file.
1 In the Welcome screen, click Next.
2 Read and understand the warning and click Next.
3 Select Use Current Log In Credentials or enter a user name and password
with schema administrator rights.
4 Click Next to run the Dell Schema Extender.
5 Click Finish.
The schema is extended. To verify the schema extension, use the MMC
and the Active Directory Schema Snap-in to verify that the following exist:
•

Classes (see Table 6-2 through Table 6-7)

•

Attributes (Table 6-8)

See your Microsoft documentation for details about using the MMC and
the Active Directory Schema Snap-in.

120

Using iDRAC6 With Microsoft Active Directory

Table 6-2.

Class Definitions for Classes Added to the Active Directory Schema

Class Name

Assigned Object Identification Number (OID)

delliDRACDevice

1.2.840.113556.1.8000.1280.1.7.1.1

delliDRACAssociation 1.2.840.113556.1.8000.1280.1.7.1.2
dellRAC4Privileges

1.2.840.113556.1.8000.1280.1.1.1.3

dellPrivileges

1.2.840.113556.1.8000.1280.1.1.1.4

dellProduct

1.2.840.113556.1.8000.1280.1.1.1.5

Table 6-3.

dellRacDevice Class

OID

1.2.840.113556.1.8000.1280.1.7.1.1

Description

Represents the Dell iDRAC6 device. iDRAC6 must be
configured as delliDRACDevice in Active Directory.
This configuration enables iDRAC6 to send Lightweight
Directory Access Protocol (LDAP) queries to Active Directory.

Class Type

Structural Class

SuperClasses

dellProduct

Attributes

dellSchemaVersion
dellRacType

Table 6-4.

delliDRACAssociationObject Class

OID

1.2.840.113556.1.8000.1280.1.7.1.2

Description

Represents the Dell Association Object. The Association Object
provides the connection between the users and the devices.

Class Type

Structural Class

SuperClasses

Group

Attributes

dellProductMembers
dellPrivilegeMember

Using iDRAC6 With Microsoft Active Directory

121

Table 6-5.

dellRAC4Privileges Class

OID

1.2.840.113556.1.8000.1280.1.1.1.3

Description

Defines the privileges (Authorization Rights) for iDRAC6

Class Type

Auxiliary Class

SuperClasses

None

Attributes

dellIsLoginUser
dellIsCardConfigAdmin
dellIsUserConfigAdmin
dellIsLogClearAdmin
dellIsServerResetUser
dellIsConsoleRedirectUser
dellIsVirtualMediaUser
dellIsTestAlertUser
dellIsDebugCommandAdmin

Table 6-6.

dellPrivileges Class

OID

1.2.840.113556.1.8000.1280.1.1.1.4

Description

Used as a container Class for the Dell Privileges (Authorization Rights).

Class Type

Structural Class

SuperClasses

User

Attributes

dellRAC4Privileges

Table 6-7.

dellProduct Class

OID

1.2.840.113556.1.8000.1280.1.1.1.5

Description

The main class from which all Dell products are derived.

Class Type

Structural Class

SuperClasses

Computer

Attributes

dellAssociationMembers

122

Using iDRAC6 With Microsoft Active Directory

Table 6-8.

List of Attributes Added to the Active Directory Schema

Attribute Name/Description

Assigned OID/Syntax Object Identifier

Single
Valued

dellPrivilegeMember

1.2.840.113556.1.8000.1280.1.1.2.1

FALSE

List of dellPrivilege Objects that
belong to this Attribute.

Distinguished Name (LDAPTYPE_DN
1.3.6.1.4.1.1466.115.121.1.12)

dellProductMembers

1.2.840.113556.1.8000.1280.1.1.2.2

List of dellRacDevice and
DelliDRACDevice Objects that
belong to this role. This attribute
is the forward link to the
dellAssociationMembers
backward link.

Distinguished Name (LDAPTYPE_DN
1.3.6.1.4.1.1466.115.121.1.12)

FALSE

Link ID: 12070
dellIsLoginUser

1.2.840.113556.1.8000.1280.1.1.2.3

TRUE

TRUE if the user has Login rights Boolean (LDAPTYPE_BOOLEAN
on the device.
1.3.6.1.4.1.1466.115.121.1.7)
dellIsCardConfigAdmin

1.2.840.113556.1.8000.1280.1.1.2.4

TRUE if the user has Card
Configuration rights on
the device.

Boolean (LDAPTYPE_BOOLEAN
1.3.6.1.4.1.1466.115.121.1.7)

dellIsUserConfigAdmin

1.2.840.113556.1.8000.1280.1.1.2.5

TRUE if the user has User
Configuration rights on the
device.

Boolean (LDAPTYPE_BOOLEAN
1.3.6.1.4.1.1466.115.121.1.7)

delIsLogClearAdmin

1.2.840.113556.1.8000.1280.1.1.2.6

TRUE

TRUE

TRUE

TRUE if the user has Log Clearing Boolean (LDAPTYPE_BOOLEAN
rights on the device.
1.3.6.1.4.1.1466.115.121.1.7)
dellIsServerResetUser

1.2.840.113556.1.8000.1280.1.1.2.7

TRUE

TRUE if the user has Server Reset Boolean (LDAPTYPE_BOOLEAN
rights on the device.
1.3.6.1.4.1.1466.115.121.1.7)
dellIsConsoleRedirectUser

1.2.840.113556.1.8000.1280.1.1.2.8

TRUE if the user has Console
Redirection rights on the device.

Boolean (LDAPTYPE_BOOLEAN
1.3.6.1.4.1.1466.115.121.1.7)

Using iDRAC6 With Microsoft Active Directory

TRUE

123

Table 6-8.

List of Attributes Added to the Active Directory Schema (continued)

Attribute Name/Description

Assigned OID/Syntax Object Identifier

Single
Valued

dellIsVirtualMediaUser

1.2.840.113556.1.8000.1280.1.1.2.9

TRUE

TRUE if the user has Virtual
Media rights on the device.

Boolean (LDAPTYPE_BOOLEAN
1.3.6.1.4.1.1466.115.121.1.7)

dellIsTestAlertUser

1.2.840.113556.1.8000.1280.1.1.2.10

TRUE if the user has Test Alert
User rights on the device.

Boolean (LDAPTYPE_BOOLEAN
1.3.6.1.4.1.1466.115.121.1.7)

dellIsDebugCommandAdmin

1.2.840.113556.1.8000.1280.1.1.2.11

TRUE if the user has Debug
Command Admin rights on
the vdevice.

Boolean (LDAPTYPE_BOOLEAN
1.3.6.1.4.1.1466.115.121.1.7)

dellSchemaVersion

1.2.840.113556.1.8000.1280.1.1.2.12

The Current Schema Version is
used to update the schema.

Case Ignore String
(LDAPTYPE_CASEIGNORESTRING
1.2.840.113556.1.4.905)

dellRacType

1.2.840.113556.1.8000.1280.1.1.2.13

TRUE

TRUE

TRUE

TRUE

This attribute is the Current RAC Case Ignore String
(LDAPTYPE_CASEIGNORESTRING
Type for the delliDRACDevice
1.2.840.113556.1.4.905)
object and the backward link to
the dellAssociationObjectMembers
forward link.

dellAssociationMembers

1.2.840.113556.1.8000.1280.1.1.2.14

List of

Distinguished Name (LDAPTYPE_DN

dellAssociationObjectMembers that 1.3.6.1.4.1.1466.115.121.1.12)
belong to this Product. This

attribute is the backward link to
the dellProductMembers linked
attribute.
Link ID: 12071

124

Using iDRAC6 With Microsoft Active Directory

FALSE

Installing the Dell Extension to the Active Directory Users and
Computers Snap-In
When you extend the schema in Active Directory, you must also extend the
Active Directory Users and Computers Snap-in so the administrator can
manage iDRAC6 devices, Users and User Groups, iDRAC6 Associations,
and iDRAC6 Privileges.
When you install your systems management software using the Dell Systems
Management Tools and Documentation DVD, you can extend the Snap-in by
selecting the Active Directory Users and Computers Snap-in option during
the installation procedure. See the Dell OpenManage Software Quick
Installation Guide for additional instructions about installing systems
management software. For 64-bit Windows Operating Systems, the Snap-in
installer is located under:
:\SYSMGMT\ManagementStation\support\OMActiveDirect
ory_SnapIn64
For more information about the Active Directory Users and Computers
Snap-in, see your Microsoft documentation.
Installing the Administrator Pack

You must install the Administrator Pack on each system that is managing the
Active Directory iDRAC6 Objects. If you do not install the Administrator
Pack, you cannot view the Dell iDRAC6 Object in the container.
See "Opening the Active Directory Users and Computers Snap-In" for more
information.
Opening the Active Directory Users and Computers Snap-In

To open the Active Directory Users and Computers Snap-in:
1 If you are logged in to the domain controller, click Start Admin Tools→
Active Directory Users and Computers.
If you are not logged in to the domain controller, you must have the
appropriate Microsoft Administrator Pack installed on your local system. To
install this Administrator Pack, click Start→ Run, enter MMC, and press Enter.
The MMC appears.
2 In the Console 1 window, click File (or Console on systems running
Windows 2000).
Using iDRAC6 With Microsoft Active Directory

125

3 Click Add/Remove Snap-in.
4 Select the Active Directory Users and Computers Snap-in and click Add.
5 Click Close and click OK.

Adding iDRAC6 Users and Privileges to Active Directory
Using the Dell-extended Active Directory Users and Computers Snap-in, you
can add iDRAC6 users and privileges by creating iDRAC6, Association, and
Privilege objects. To add each object type, perform the following procedures:
•

Create an iDRAC6 device Object

•

Create a Privilege Object

•

Create an Association Object

•

Add objects to an Association Object

Creating an iDRAC6 Device Object

1 In the MMC Console Root window, right-click a container.
2 Select New→ Dell Remote Management Object Advanced.
The New Object window appears.
3 Enter a name for the new object. The name must be identical to the
iDRAC6 name that you will enter in Step A of "Configuring Active
Directory With Extended Schema Using the iDRAC6 Web-Based
Interface."
4 Select iDRAC Device Object.
5 Click OK.
Creating a Privilege Object

NOTE: A Privilege Object must be created in the same domain as the related
Association Object.
1 In the Console Root (MMC) window, right-click a container.
2 Select New→ Dell Remote Management Object Advanced.
The New Object window appears.
3 Enter a name for the new object.
4 Select Privilege Object.
126

Using iDRAC6 With Microsoft Active Directory

5 Click OK.
6 Right-click the privilege object that you created, and select Properties.
7 Click the Remote Management Privileges tab and select the privileges
that you want the user or group to have (see Table 5-10).
Creating an Association Object

NOTE: The iDRAC6 Association Object is derived from Group and its scope is set to
Domain Local.
1 In the Console Root (MMC) window, right-click a container.
2 Select New→ Dell Remote Management Object Advanced.
This opens the New Object window.
3 Enter a name for the new object.
4 Select Association Object.
5 Select the scope for the Association Object.
6 Click OK.
Adding Objects to an Association Object

Using the Association Object Properties window, you can associate users or
user groups, privilege objects, and iDRAC6 devices or iDRAC6 device groups.
You can add groups of Users and iDRAC6 devices. The procedure for creating
Dell-related groups and non-Dell-related groups is identical.
Adding Users or User Groups

1 Right-click the Association Object and select Properties.
2 Select the Users tab and click Add.
3 Enter the user or User Group name and click OK.
Adding Privileges

1 Select the Privileges Object tab and click Add.
2 Enter the Privilege Object name and click OK.
Click the Privilege Object tab to add the privilege object to the association that
defines the user’s or user group’s privileges when authenticating to an iDRAC6
device. Only one privilege object can be added to an Association Object.
Using iDRAC6 With Microsoft Active Directory

127

Adding iDRAC6 Devices or iDRAC6 Device Groups

To add iDRAC6 devices or iDRAC6 device groups:
1 Select the Products tab and click Add.
2 Enter iDRAC6 devices or iDRAC6 device group name and click OK.
3 In the Properties window, click Apply and click OK.
Click the Products tab to add one iDRAC6 device connected to the network
that is available for the defined users or user groups. You can add multiple
iDRAC6 devices to an Association Object.

Configuring Active Directory With Extended Schema Using the iDRAC6
Web-Based Interface
1 Open a supported Web browser window.
2 Log in to the iDRAC6 Web-based interface.
3 In the system tree, select System→ Remote Access→ iDRAC.
The iDRAC Information screen appears.
4 Click the Network Security tab, and then click Active Directory.
The Active Directory Configuration and Management screen appears.
5 Scroll to the bottom of the screen and click Configure Active Directory.
The Step 1 of 4 Active Directory Configuration and Management screen
appears.
6 To validate the SSL certificate of your Active Directory servers, select the
Enable Certificate Validation check box under Certificate Settings.
If you don’t want to validate the SSL certificate of your Active Directory
servers, take no action, and skip to step 8.
7 Under Upload Active Directory CA Certificate, enter the file path of the
certificate or browse to find the certificate file, and then click Upload.
NOTE: You must enter the absolute file path, which includes the full path and
the complete file name and file extension.

The certificate information for the Active Directory CA certificate that you
uploaded appears in the Current Active Directory CA Certificate section.

128

Using iDRAC6 With Microsoft Active Directory

8 Click Next.
The Step 2 of 4 Active Directory Configuration and Management
screen appears.
9 Select the Enable Active Directory check box.
10 Click Add to enter the user domain name, enter the user domain name in
the text field, and then click OK.
11 Type the user domain name in the prompt and click OK. Note that this
step is optional. If you configure a list of user domains, the list will be
available in the Web-based interface login screen. You can choose from
the list, and then you only need to enter the user name.
12 In the Timeout field, enter the number of seconds you want iDRAC6 to
wait for Active Directory responses. The default is 120 seconds.
13 Enter the Domain Controller Server Address. You can enter up to three
Active Directory servers for login processing, but you must configure at
least one server by entering the IP address or the fully qualified domain
name (FQDN). iDRAC6 attempts to connect to each configured server
until a connection is established.
NOTE: The FQDN or IP address that you specify in this field should match the
Subject or Subject Alternative Name field of your domain controller
certificate if you have certificate validation enabled.

14 Click Next.
The Step 3 of 4 Active Directory Configuration and Management
screen appears.
15 Under Schema Selection, select the Extended Schema check box.
16 Click Next.
The Step 4 of 4 Active Directory Configuration and Management
screen appears.
17 Under Extended Schema Settings, enter the iDRAC6 name and iDRAC6
domain name to configure the iDRAC6 device object and its location in
Active Directory.
18 Click Finish to save your changes, and then Done.
The main Active Directory Configuration and Management appears.
Next, you must test the Active Directory settings you just configured.

Using iDRAC6 With Microsoft Active Directory

129

19 Scroll to the bottom of the screen and click Test Settings.
The Test Active Directory Settings screen appears.
20 Enter your iDRAC6 user name and password, and then click Start Test.
Test results and the test log display. For additional information, see
"Testing Your Configurations."
NOTE: You must have a DNS server configured properly on iDRAC6 to support
Active Directory log in. Navigate to the Network Configuration screen (click
System→ Remote Access→ iDRAC, and then click the Network/Security tab) to
configure DNS server(s) manually or use DHCP to get DNS server(s).
You have completed the Active Directory configuration with Extended Schema.

Configuring Active Directory With Extended Schema Using RACADM
Use the following commands to configure the iDRAC6 Active Directory
feature with Extended Schema using the RACADM command line interface
(CLI) tool instead of the Web-based interface.
1 Open a command prompt and enter the following RACADM commands:
racadm config -g cfgActiveDirectory -o cfgADEnable 1
racadm config -g cfgActiveDirectory -o cfgADType 1
racadm config -g cfgActiveDirectory -o
cfgADRacName 
racadm config -g cfgActiveDirectory -o
cfgADRacDomain 
racadm config -g cfgActiveDirectory -o
cfgDomainController1 
racadm config -g cfgActiveDirectory -o
cfgDomainController2 
racadm config -g cfgActiveDirectory -o
cfgDomainController3 

130

Using iDRAC6 With Microsoft Active Directory

NOTE: You must configure at least one of the three addresses. iDRAC6
attempts to connect to each of the configured addresses one-by-one until a
successful connection is made. With Extended Schema, these are the FQDN
or IP addresses of the domain controllers where this iDRAC6 device is
located. Global catalog servers are not used in extended schema mode at all.

If you want to disable the certificate validation during SSL handshake,
enter the following RACADM command:
racadm config -g cfgActiveDirectory -o
cfgADCertValidationEnable 0
In this case, you do not have to upload a CA certificate.
If you want to enforce the certificate validation during SSL handshake,
enter the following RACADM command:
racadm config -g cfgActiveDirectory -o
cfgADCertValidationEnable 1
In this case, you must upload a CA certificate using the following
RACADM command:
racadm sslcertupload -t 0x2 -f 
Using the following RACADM command may be optional. See "Importing
the iDRAC6 Firmware SSL Certificate" for additional information.
racadm sslcertdownload -t 0x1 -f 
2 If DHCP is enabled on iDRAC6 and you want to use the DNS provided by
the DHCP server, enter the following RACADM command:
racadm config -g cfgLanNetworking -o
cfgDNSServersFromDHCP 1
3 If DHCP is disabled in iDRAC6 or you want to manually input your DNS
IP address, enter the following RACADM commands:
racadm config -g cfgLanNetworking -o
cfgDNSServersFromDHCP 0
racadm config -g cfgLanNetworking -o cfgDNSServer1

racadm config -g cfgLanNetworking -o cfgDNSServer2

Using iDRAC6 With Microsoft Active Directory

131

4 If you want to configure a list of user domains so that you only need to
enter the user name during log in to the iDRAC6 Web-based interface,
enter the following command:
racadm config -g cfgUserDomain -o
cfgUserDomainName -i 
You can configure up to 40 user domains with index numbers between
1 and 40.
See "Using Active Directory to Log In to iDRAC6" for details about user
domains.
5 Press Enter to complete the Active Directory configuration with
Extended Schema.

Standard Schema Active Directory Overview
As shown in Figure 6-3, using standard schema for Active Directory
integration requires configuration on both Active Directory and iDRAC6.
Figure 6-3. Configuration of iDRAC6 with Microsoft Active Directory and
Standard Schema
Configuration on Active
Directory Side

Role
Group

Configuration on
iDRAC Side

Role
Group Name
and Domain
Name

User

132

Using iDRAC6 With Microsoft Active Directory

Role
Definition

On the Active Directory side, a standard group object is used as a role group.
A user who has iDRAC6 access will be a member of the role group. To give
this user access to a specific iDRAC6 card, the role group name and its
domain name need to be configured on the specific iDRAC6 card. Unlike the
extended schema solution, the role and the privilege level is defined on each
iDRAC6 card, not in the Active Directory. Up to five role groups can be
configured and defined in each iDRAC6. Table 6-9 shows the default role
group privileges.
Table 6-9.

Default Role Group Privileges

Role
Groups

Default Privilege Permissions Granted
Level

Bit Mask

Role
Group 1

Administrator

Login to iDRAC, Configure iDRAC,
Configure Users, Clear Logs,
Execute Server Control Commands,
Access Console Redirection,
Access Virtual Media, Test Alerts,
Execute Diagnostic Commands

0x000001ff

Role
Group 2

Operator

Login to iDRAC, Configure iDRAC,
Execute Server Control Commands,
Access Console Redirection,
Access Virtual Media, Test Alerts,
Execute Diagnostic Commands

0x000000f9

Role
Group 3

Read Only

Login to iDRAC

0x00000001

Role
Group 4

None

No assigned permissions

0x00000000

Role
Group 5

None

No assigned permissions

0x00000000

NOTE: The Bit Mask values are used only when setting Standard Schema with
the RACADM.

Using iDRAC6 With Microsoft Active Directory

133

Single Domain Versus Multiple Domain Scenarios
If all of the login users and role groups, as well as the nested groups, are in the
same domain, then only the domain controllers’ addresses must be configured
on iDRAC6. In this single domain scenario, any group type is supported.
If all of the login users and role groups, or any of the nested groups, are from
multiple domains, then Global Catalog server addresses are required to be
configured on iDRAC6. In this multiple domain scenario, all of the role
groups and nested groups, if any, must be Universal Group type.

Configuring Standard Schema Active Directory to Access iDRAC6
You must perform the following steps to configure Active Directory before an
Active Directory user can access iDRAC6:
1 On an Active Directory server (domain controller), open the Active
Directory Users and Computers Snap-in.
2 Create a group or select an existing group. The name of the group and the
name of this domain must be configured on iDRAC6 by using either the
Web-based interface or RACADM (see "Configuring Active Directory
With Standard Schema Using the iDRAC6 Web-Based Interface" or
"Configuring Active Directory With Standard Schema Using RACADM").
3 Add the Active Directory user as a member of the Active Directory group
to access iDRAC6.

Configuring Active Directory With Standard Schema Using the iDRAC6
Web-Based Interface
1 Open a supported Web browser window.
2 Log in to the iDRAC6 Web interface.
3 In the system tree, select System→ Remote Access→ iDRAC.
4 Click the Network Security tab, and then click Active Directory.
The Active Directory Configuration and Management screen appears.
5 Scroll to the bottom of the screen and click Configure Active Directory.
The Step 1 of 4 Active Directory Configuration and Management
screen appears.
6 Under Certificate Settings, select Enable Active Directory.
134

Using iDRAC6 With Microsoft Active Directory

7 Under Upload Active Directory CA Certificate, enter the file path of the
certificate or browse to find the certificate file, and then click Upload.
NOTE: You must enter the absolute file path, which includes the full path and
the complete file name and file extension.

The certificate information for the Active Directory CA certificate that you
uploaded appears in the Current Active Directory CA Certificate section.
8 Click Next.
The Step 2 of 4 Active Directory Configuration and Management
screen appears.
9 Select the Enable Active Directory check box.
10 Click Add to enter the user domain name, enter the user domain name in
the text field, and then click OK.
11 In the Timeout field, enter the number of seconds you want iDRAC6 to
wait for Active Directory responses. The default is 120 seconds.
12 Enter the Domain Controller Server Address. You can enter up to three
Active Directory servers for login processing, but you must configure at
least one server by entering the IP address or the fully qualified domain
name (FQDN). iDRAC6 attempts to connect to each configured server
until a connection is established.
13 Click Next.
The Step 3 of 4 Active Directory Configuration and Management
screen appears.
14 Under Schema Selection, select the Standard Schema check box.
15 Click Next.
The Step 4a of 4 Active Directory Configuration and Management
screen appears.
16 Under Standard Schema Settings, enter the Global Catalog
Server Address(es).
NOTE: The Global Catalog server is only required for standard schema when
the user accounts and role groups are in different domains. And, in this
multiple domain case, only the Universal Group can be used.

17 Click a Role Group button to add a role group.
The Step 4b of 4 Configure Role Group 1 screen appears.
Using iDRAC6 With Microsoft Active Directory

135

18 Enter the Group Name. The group name identifies the role group in the
Active Directory associated with iDRAC6.
19 Enter the Group Domain. The Group Domain is the fully qualified root
domain name for the forest.
20 In the Role Group Privileges section, set the group privileges. Refer to
Table 5-11 on page 93 for information on role group privileges.
NOTE: If you modify any of the permissions, the existing role group privilege
(Administrator, Power User, or Guest User) will change to either the Custom
Group or the appropriate role group privilege based on the permissions you
modified.

21 Click OK to save the role group settings.
An alert dialog appears, indicating that your settings are changed.
Click OK to return to the Step 4a of 4 Active Directory Configuration
and Management screen.
22 To add an additional role group, repeat step 17 through step 21.
23 Click Finish, and the click Done.
The main Active Directory Configuration and Management appears.
Next, you must test the Active Directory settings you just configured.
24 Scroll to the bottom of the screen and click Test Settings.
The Test Active Directory Settings screen appears.
25 Enter your iDRAC6 user name and password, and then click Start Test.
Test results and the test log display. For additional information,
see "Testing Your Configurations."
NOTE: You must have a DNS server configured properly on iDRAC6 to support
Active Directory login. Navigate to Remote Access→ Configuration→ Network
page to configure DNS server(s) manually or use DHCP to get DNS server(s).
You have completed the Active Directory configuration with Standard Schema.

136

Using iDRAC6 With Microsoft Active Directory

Configuring Active Directory With Standard Schema Using RACADM
Use the following commands to configure the iDRAC6 Active Directory
Feature with Standard Schema using the RACADM CLI instead of the
Web-based interface.
1 Open a command prompt and enter the following RACADM commands:
racadm config -g cfgActiveDirectory -o
cfgADEnable 1
racadm config -g cfgActiveDirectory -o cfgADType 2
racadm config -g cfgStandardSchema -i  -o
cfgSSADRoleGroupName 
racadm config -g cfgStandardSchema -i  -o
cfgSSADRoleGroupDomain 
racadm config -g cfgStandardSchema -i  -o
cfgSSADRoleGroupPrivilege 
NOTE: For Bit Mask Number values, see Table B-1.
racadm config -g cfgActiveDirectory -o
cfgDomainController1 
racadm config -g cfgActiveDirectory -o
cfgDomainController2 
racadm config -g cfgActiveDirectory -o
cfgDomainController3 
NOTE: Enter the FQDN of the domain controller, not the FQDN of the domain.
For example, enter servername.dell.com instead of dell.com.
NOTE: At least one of the 3 addresses is required to be configured. iDRAC6
attempts to connect to each of the configured addresses one-by-one until a
successful connection is made. With Standard Schema, these are the
addresses of the domain controllers where the user accounts and the role
groups are located.

Using iDRAC6 With Microsoft Active Directory

137

racadm config -g cfgActiveDirectory -o cfgGlobal
Catalog1 
racadm config -g cfgActiveDirectory -o cfgGlobal
Catalog2 
racadm config -g cfgActiveDirectory -o cfgGlobal
Catalog3 
NOTE: The Global Catalog server is only required for standard schema when
the user accounts and role groups are in different domains. And, in this
multiple domain case, only the Universal Group can be used.

NOTE: The FQDN or IP address that you specify in this field should match the
Subject or Subject Alternative Name field of your domain controller certificate
if you have certificate validation enabled.

If you want to disable the certificate validation during SSL handshake,
enter the following RACADM command:
racadm config -g cfgActiveDirectory -o
cfgADCertValidationEnable 0
In this case, no Certificate Authority (CA) certificate needs to be uploaded.
If you want to enforce the certificate validation during SSL handshake,
enter the following RACADM command:
racadm config -g cfgActiveDirectory -o
cfgADCertValidationEnable 1
In this case, you must also upload the CA certificate using the following
RACADM command:
racadm sslcertupload -t 0x2 -f 
Using the following RACADM command may be optional. See "Importing
the iDRAC6 Firmware SSL Certificate" for additional information.
racadm sslcertdownload -t 0x1 -f 

138

Using iDRAC6 With Microsoft Active Directory

2 If DHCP is enabled on iDRAC6 and you want to use the DNS provided by
the DHCP server, enter the following RACADM commands:
racadm config -g cfgLanNetworking -o
cfgDNSServersFromDHCP 1
3 If DHCP is disabled on iDRAC6 or you want manually to input your DNS
IP address, enter the following RACADM commands:
racadm config -g cfgLanNetworking -o
cfgDNSServersFromDHCP 0
racadm config -g cfgLanNetworking -o cfgDNSServer1

racadm config -g cfgLanNetworking -o cfgDNSServer2

4 If you want to configure a list of user domains so that you only need to
enter the user name when logging in to the Web-based interface, enter the
following command:
racadm config -g cfgUserDomain -o
cfgUserDomainName -i 
Up to 40 user domains can be configured with index numbers between
1 and 40.
See "Using Active Directory to Log In to iDRAC6" for details about
user domains.

Testing Your Configurations
If you want to verify whether your configuration works, or if you need to
diagnose the problem with your failed Active Directory log in, you can test
your settings from the iDRAC6 Web-based interface.
After you finish configuring settings in the iDRAC6 Web-based interface,
click Test Settings at the bottom of the screen. You will be required to enter a
test user's name (for example, username@domain.com) and password to run
the test. Depending on your configuration, it may take some time for all of
the test steps to complete and display the results of each step. A detailed test
log will display at the bottom of the results screen.

Using iDRAC6 With Microsoft Active Directory

139

If there is a failure in any step, examine the details in the test log to identify
the problem and a possible solution. For most common errors, see
"Frequently Asked Questions."
If you need to make changes to your settings, click the Active Directory tab
and change the configuration step-by-step.

Enabling SSL on a Domain Controller
When iDRAC6 authenticates users against an Active Directory domain
controller, it starts an SSL session with the domain controller. At this time,
the domain controller should publish a certificate signed by the Certificate
Authority (CA)—the root certificate of which is also uploaded into iDRAC6.
In other words, for iDRAC6 to authenticate to any domain controller—
whether it is the root or the child domain controller—that domain controller
should have an SSL-enabled certificate signed by the domain’s CA.
If you are using Microsoft Enterprise Root CA to automatically assign all your
domain controllers to an SSL certificate, perform the following steps to
enable SSL on each domain controller:
1 Enable SSL on each of your domain controllers by installing the SSL
certificate for each controller.
a

Click Start→ Administrative Tools→ Domain Security Policy.

b

Expand the Public Key Policies folder, right-click Automatic
Certificate Request Settings and click Automatic Certificate Request.

c

In the Automatic Certificate Request Setup Wizard, click Next and
select Domain Controller.

d

Click Next and click Finish.

Exporting the Domain Controller Root CA Certificate to iDRAC6
NOTE: If your system is running Windows 2000, the following steps may vary.
NOTE: If you are using a standalone CA, the following steps may vary.
1 Locate the domain controller that is running the Microsoft Enterprise
CA service.
2 Click Start→ Run.
3 In the Run field, enter mmc and click OK.
140

Using iDRAC6 With Microsoft Active Directory

4 In the Console 1 (MMC) window, click File (or Console on Windows 2000
systems) and select Add/Remove Snap-in.
5 In the Add/Remove Snap-In window, click Add.
6 In the Standalone Snap-In window, select Certificates and click Add.
7 Select Computer account and click Next.
8 Select Local Computer and click Finish.
9 Click OK.
10 In the Console 1 window, expand the Certificates folder, expand the
Personal folder, and click the Certificates folder.
11 Locate and right-click the root CA certificate, select All Tasks, and click
Export...
12 In the Certificate Export Wizard, click Next, and select No do not export
the private key.
13 Click Next and select Base-64 encoded X.509 (.cer) as the format.
14 Click Next and save the certificate to a directory on your system.
15 Upload the certificate you saved in step 14 to iDRAC6.
To upload the certificate using RACADM, see "Configuring Active
Directory With Standard Schema Using RACADM."
To upload the certificate using the Web-based interface, see "Configuring
Active Directory With Standard Schema Using the iDRAC6 Web-Based
Interface."

Importing the iDRAC6 Firmware SSL Certificate
NOTE: If the Active Directory Server is set to authenticate the client during an SSL
session initialization phase, you need to upload the iDRAC6 Server certificate to the
Active Directory Domain controller as well. This additional step is not required if the
Active Directory does not perform a client authentication during an SSL session’s
initialization phase.
Use the following procedure to import the iDRAC6 firmware SSL certificate
to all domain controller trusted certificate lists.
NOTE: If your system is running Windows 2000, the following steps may vary.
NOTE: If the iDRAC6 firmware SSL certificate is signed by a well-known CA and the
certificate of that CA is already in the domain controller's Trusted Root Certificate
Authority list, you are not required to perform the steps in this section.
Using iDRAC6 With Microsoft Active Directory

141

The iDRAC6 SSL certificate is the identical certificate used for the iDRAC6
Web server. All iDRAC6 controllers are shipped with a default self-signed
certificate.
To download the iDRAC6 SSL certificate, run the following RACADM
command:
racadm sslcertdownload -t 0x1 -f 
1 On the domain controller, open an MMC Console window and select
Certificates→ Trusted Root Certification Authorities.
2 Right-click Certificates, select All Tasks and click Import.
3 Click Next and browse to the SSL certificate file.
4 Install the iDRAC6 SSL Certificate in each domain controller’s Trusted
Root Certification Authority.
If you have installed your own certificate, ensure that the CA signing your
certificate is in the Trusted Root Certification Authority list. If the
Authority is not in the list, you must install it on all your Domain Controllers.
5 Click Next and select whether you would like Windows to automatically
select the certificate store based on the type of certificate, or browse to a
store of your choice.
6 Click Finish and click OK.

Using Active Directory to Log In to iDRAC6
You can use Active Directory to log in to iDRAC6 using one of the following
methods:
•

Web-based interface

•

Local RACADM

•

SSH or telnet console for SM-CLP CLI

The login syntax is the same for all three methods:

or
\ or /
where username is an ASCII string of 1–256 bytes.

142

Using iDRAC6 With Microsoft Active Directory

White space and special characters (such as \, /, or @) cannot be used in the
user name or the domain name.
NOTE: You cannot specify NetBIOS domain names, such as Americas, because
these names cannot be resolved.
If you log in from the Web-based interface and you have configured user
domains, the Web-based interface log in screen will list all the user domains in
the pull-down menu for your to choose. If you select a user domain from the
pull-down menu, you should only enter the user name. If you select
This iDRAC, you can still log in as an Active Directory user if you use the login
syntax described above in "Using Active Directory to Log In to iDRAC6."

Frequently Asked Questions
Active Directory Log In Issues
My Active Directory log in failed. What do I do?

iDRAC6 provides a diagnostic tool in the Web-based interface.
1 Log in as a local user with administrator privilege from the Web-based
interface.
2 In the system tree, select System→ Remote Access→ iDRAC.
3 Click the Network/Security tab, and then click the Active Directory sub-tab.
The Active Directory Configuration and Management screen appears.
4 Scroll to the bottom of the screen and click Test Settings.
The Test Active Directory Settings screen appears.
5 Enter a test user name and password, and then click Start Test.
iDRAC6 runs the tests step-by-step and displays the result for each step.
iDRAC6 also logs a detailed test result to help you resolve any problems.
If problems persist:
a

On the Test Settings screen, click the Active Directory sub-tab to return
to the Active Directory Configuration and Management screen.

b

Scroll to the bottom of the screen and click Configure Active Directory.

c

Change your user configuration, and run the test again until the test
user passes the authorization step.

Using iDRAC6 With Microsoft Active Directory

143

I enabled certificate validation but I failed my Active Directory log in. I ran the
diagnostics from the GUI and the test result shows the following error message:

ERROR: Can't contact LDAP server,
error:14090086:SSL
routines:SSL3_GET_SERVER_CERTIFICATE:certificate
verify failed: Please check the correct
Certificate Authority (CA) certificate has been
uploaded to iDRAC. Please also check if the iDRAC
date is within the valid period of the
certificates and if the Domain Controller Address
configured in iDRAC matches the subject of the
Directory Server Certificate.
What could the problem be and how do I fix it?

If certificate validation is enabled, iDRAC6 uses the uploaded CA certificate
to verify the directory server certificate when iDRAC6 establishes the SSL
connection with the directory server. The most common reasons for failing
certification validation are:

144

•

The iDRAC6 date is not within the valid period of the server certificate or
CA certificate. Check the iDRAC6 time and the valid period of
your certificate.

•

The Domain Controller Addresses configured in iDRAC6 do not match
the Subject or Subject Alternative Name of the directory server certificate.
–

If you are using an IP address, see "I'm using an IP address for a
Domain Controller Address, and I failed certificate validation. What's
the problem?".

–

If you are using FQDN, ensure you are using the FQDN of the domain
controller, and not the domain itself. For example, use
servername.example.com and not example.com.

Using iDRAC6 With Microsoft Active Directory

What should I check if I cannot log in to iDRAC6 using Active Directory?

First, diagnose the problem using the Test Settings feature. For directions,
see "My Active Directory log in failed. What do I do?"
Then, fix the specific problem indicated by the test results. For additional
information, see "Testing Your Configurations."
Most common issues are explained in this section. However, in general,
you should check the following:
1 Ensure that you use the correct user domain name during a log in and not
the NetBIOS name.
2 If you have a local iDRAC6 user account, log in to iDRAC6 using your
local credentials.
3 Check the following settings:
a

Navigate to the Active Directory Configuration and Management
screen. Select System→ Remote Access→ iDRAC, click the Network/
Security tab, and then click the Active Directory subtab.

b

Ensure that the Active Directory Enabled check box is checked.

c

If you enabled certificate validation, ensure that you have uploaded
the correct Active Directory root CA certificate to iDRAC6. The
certificate appears in the Active Directory CA Certificate area.
Ensure that the iDRAC6 time is within the valid period of the CA
certificate.

d

If you are using the Extended Schema, ensure that the iDRAC Name
and iDRAC Domain Name match your Active Directory environment
configuration.
If you are using the Standard Schema, ensure that the Group Name
and Group Domain Name match your Active Directory configuration.

e

Navigate to the Network Configuration screen. Select System→
Remote Access→ iDRAC, and then click Network/Security.
Ensure that the DNS settings are correct.

f

Check the Domain Controller SSL certificates to ensure that the
iDRAC6 time is within the valid period of the certificate.

Using iDRAC6 With Microsoft Active Directory

145

Active Directory Certificate Validation
I'm using an IP address for a Domain Controller Address, and I failed certificate
validation. What's the problem?

Check the Subject or Subject Alternative Name field of your domain controller
certificate. Usually Active Directory uses the hostname, not the IP address,
of the domain controller in the Subject or Subject Alternative Name field of
the domain controller certificate. You can fix the problem by taking any of
the following actions:
•

Configure the hostname (FQDN) of the domain controller as the domain
controller address(es) on iDRAC6 to match the Subject or Subject
Alternative Name of the server certificate.

•

Re-issue the server certificate to use an IP address in the Subject or
Subject Alternative Name field so it matches the IP address configured
in iDRAC6.

•

Disable certificate validation if you choose to trust this domain controller
without certificate validation during the SSL handshake.

Why does iDRAC6 enable certificate validation by default?

iDRAC6 enforces strong security to ensure the identity of the domain
controller that iDRAC6 connects to. Without certificate validation, a hacker
could spoof a domain controller and hijack the SSL connection. If you choose
to trust all the domain controllers in your security boundary without
certificate validation, you can disable it through the GUI or the CLI.

Extended and Standard Schema
I'm using extended schema in a multiple domain environment. How do I configure
the domain controller address(es)?

Use the host name (FQDN) or the IP address of the domain controller(s) that
serves the domain in which the iDRAC6 object resides.
Do I need to configure Global Catalog Address(es)?

If you are using extended schema, you cannot configure global catalog
addresses, because they are not used with extended schema.

146

Using iDRAC6 With Microsoft Active Directory

If you are using standard schema, and users and role groups are from different
domains, you must configure global catalog address(es). In this case, you can
use only Universal Group.
If you are using standard schema, and all the users and all the role groups are
in the same domain, you are not required to configure global catalog
address(es).
How does standard schema query work?

iDRAC6 connects to the configured domain controller address(es) first. If the
user and role groups reside in that domain, the privileges are saved.
If global controller address(es) is configured, iDRAC6 continues to query the
Global Catalog. If additional privileges are retrieved from the Global Catalog,
these privileges are accumulated.

Miscellaneous
Does iDRAC6 always use LDAP over SSL?

Yes. All the transportation is over secure port 636 and/or 3269.
During test setting, iDRAC6 does a LDAP CONNECT only to help isolate
the problem, but it does not do an LDAP BIND on an insecure connection.
Does iDRAC6 support the NetBIOS name?

Not in this release.

Using iDRAC6 With Microsoft Active Directory

147

148

Using iDRAC6 With Microsoft Active Directory

Viewing the Configuration and
Health of the Managed Server
System Summary
Click System→ Properties→ Summary to obtain information about the
Main System Enclosure and the Integrated Dell Remote Access Controller.

Main System Enclosure
System Information

This section of the iDRAC6 Web interface provides the following basic
information about the managed server:
•

Description — The model number or name of the managed server

•

BIOS Version — The version number of the managed server's BIOS

•

Service Tag — The Service Tag number of the managed server

•

Host Name — The DNS hostname associated with the managed server

•

OS Name — The name of the operating system installed on the
managed server

I/O Mezzanine Card

This section of the iDRAC6 Web interface provides the following
information about the I/O Mezzanine cards installed on the managed server:
•

Connection — Lists the I/O Mezzanine card(s) installed on the
managed server

•

Card Type — The physical type of the installed Mezzanine card/connection

•

Model Name — The model number, type, or description of the installed
Mezzanine card(s)
Viewing the Configuration and Health of the Managed Server

149

Integrated Storage Card

This section of the iDRAC6 Web interface provides information about the
integrated Storage Controller Card installed on the Managed Server:
•

Card Type — shows the model name of the installed storage card

Auto Recovery

This section of the iDRAC6 Web interface details the current mode of
operation of the Auto Recovery feature of the managed server as set by
Open Manage Server Administrator:
•

Recovery Action — Action to be performed when a system fault or hang is
detected. Available actions are No Action, Hard Reset, Power Down,
or Power Cycle.

•

Initial Countdown — The amount of time (in seconds) after a system
hang is detected at which time iDRAC6 performs a recovery action.

•

Present Countdown — The current value (in seconds) of the
countdown timer.

Integrated Dell Remote Access Controller 6 - Enterprise
iDRAC6 Information

This section of the iDRAC6 Web interface provides the following
information about iDRAC6 itself:

150

•

Date/Time — The current date and time (as of last page refresh) of iDRAC6

•

Firmware Version — The current version of iDRAC6 firmware installed on
the managed server

•

Firmware Updated — The date and time of the last successful iDRAC6
firmware update

•

Hardware Version — The version number of the primary planar
(circuit board) of the managed server

•

IP Address — The IP address associated with iDRAC6 (not the
managed server)

•

Gateway — The IP address of the network gateway configured for iDRAC6

•

Subnet Mask — The TCP/IP Subnet Mask configured for iDRAC6

•

MAC Address — The MAC address associated with the LOM (LAN on
Motherboard) Network Interface Controller of iDRAC6
Viewing the Configuration and Health of the Managed Server

•

DHCP Enabled — Enabled if iDRAC6 is set to fetch its IP address and
associated info from a DHCP server

•

Preferred DNS Address 1 — Set to the currently active primary DNS server

•

Alternate DNS Address 2 — Set to the alternate DNS server address
NOTE: This information is also available at iDRAC→ Properties→ iDRAC Information.

WWN/MAC Summary
Click System→ Properties→ WWN/MAC to view the current configuration
of installed I/O Mezzanine cards and their associated network fabrics. If the
FlexAddress feature is enabled, the globally assigned (Chassis-Assigned)
persistent MAC addresses supersede the hardwired values of each LOM.

System Health
Click System→ Properties→ Health to view important information about
the health of iDRAC6 and components monitored by iDRAC6. The Severity
column shows the status for each component. For a list of status icons and
their meaning, see Table 17-3. Click the component name in the Component
column for more detailed information about the component.
NOTE: Component information can also be obtained by clicking the component
name in the left pane of the window. Components remain visible in the left pane
independent of the tab/screen that is selected.

iDRAC6
The iDRAC6 Information screen lists a number of important details about
iDRAC6, such as health status, name, firmware revision, and network
parameters. Additional details are available by clicking the appropriate tab at
the top of the screen.

CMC
The CMC screen displays the health status, firmware revision, and IP address
of the Chassis Management Controller. You can also launch the CMC Web
interface by clicking the Launch the CMC Web Interface button. See the
Chassis Management Controller Firmware User Guide.

Viewing the Configuration and Health of the Managed Server

151

Batteries
The Batteries screen displays the status and values of the system board
coin-cell battery that maintains the Real-Time Clock (RTC) and CMOS
configuration data storage of the managed system.

Temperatures
The Temperature Probes Information screen displays the status and readings
of the on-board ambient temperature probe. Minimum and maximum
temperature thresholds for warning or failure states are shown, along with the
current health status of the probe.

Voltages
The Voltage Probes Information screen displays the status and reading of the
Voltage probes, providing such information as the status of the on-board
voltage rail and CPU core sensors.
NOTE: Depending on the model of your server, temperature thresholds for warning
or failure states and/or the health status of the probe may not be displayed.

Power Monitoring
The Power Monitoring screen enables you to view the following monitoring
and power statistics information:
•

Power Monitoring — Displays the amount of power being used (in watts)
by the server as reported by the System Board Current Monitor.

•

Power Tracking Statistics — Displays information about the amount of
power used by the system since the Measurement Start Time was last
reset.

•

Peak Statistics — Displays information about the peak amount of power
used by the system since the Measurement Start Time was last reset.

CPU
The CPU Information screen reports the health of each CPU on the
managed server. This health status is a roll-up of a number of individual
thermal, power, and functional tests.

152

Viewing the Configuration and Health of the Managed Server

POST
The Post Code screen displays the last system post code (in hexadecimal)
prior to booting the operating system of the managed server.

Misc Health
The Misc Health screen provides access to the following system logs:
•

System Event Log — Displays system-critical events that occur on the
managed system.

•

Post Code — Displays the last system post code (in hexadecimal) prior to
booting the operating system of the managed server.

•

Last Crash — Displays the most recent crash screen and time.

•

Boot Capture — Provides playback of the last three boot screens.
NOTE: This information is also available at System→ Properties→ Logs.

Viewing the Configuration and Health of the Managed Server

153

154

Viewing the Configuration and Health of the Managed Server

Power Monitoring and Power
Management
Dell™ PowerEdge™ systems incorporate many new and enhanced power
management features. The entire platform, from hardware to firmware to
systems management software, has been designed with a focus on power
efficiency, power monitoring, and power management.
PowerEdge systems provide many features for monitoring and managing power:
•

Power Monitoring: iDRAC6 collects a history of power measurements
and calculates running averages, peaks, and so on. Using the iDRAC6
Web-based interface, you can view the information on the Power
Monitoring screen. You can also view the information in graph form by
clicking Show Graph at the bottom of the Power Monitoring screen.
See "Power Control" for more information.

•

Power Budgeting: At boot, a system inventory enables a system power
budget of the current configuration to be calculated. See "Power
Monitoring" for more information.

•

Power Control: iDRAC6 enables you to remotely perform several
power management actions on the managed system. See "Power Control"
for more information.

Configuring and Managing Power
You can use the iDRAC6 Web-based interface and RACADM command line
interface (CLI) to manage and configure power controls on the PowerEdge
system. Specifically, you can:
•

View the power status of the server. See "Viewing Power Monitoring."

•

View power budget information for the server, including the minimum and
maximum potential power consumption. See "Viewing Power Budget."

Power Monitoring and Power Management

155

•

View power budget threshold for the server. See "Viewing Power Budget
Threshold."

•

Execute power control operations on the server (for example, power on,
power off, system reset, power cycle). See "Executing Power Control
Operations on the Server."

Power Monitoring
iDRAC6 monitors the power consumption in PowerEdge servers continuously.
iDRAC6 calculates the following power values and provides the information
through its Web-based interface or RACADM CLI:
•

Cumulative power

•

Average, minimum, and maximum power

•

Power consumption (also shown in graphs in the Web-based interface)

•

Power budget thresholds

Viewing Power Monitoring
Using the Web Interface

To view the power monitoring data:
1 Log in to the iDRAC6 Web interface.
2 In the system tree, select Power Monitoring.
The Power Monitoring screen appears, displaying the following information:
Power Monitoring

•

Status: A green check indicates that the power status is normal, Warning
indicates that a warning alert was issued, and Severe indicates a failure
alert was issued.

•

Probe Name: System Board System Level. This description indicates the
probe is being monitored by its location in the system.

•

Reading: The current power consumption in Watts.

Amperage

156

•

Location: System Board Current Monitor Current

•

Reading: The current power consumption in Amps
Power Monitoring and Power Management

Power Tracking Statistics

•

Statistic:
–

Cumulative System Power displays the current cumulative energy
consumption (in KWh) for the server. The value represents the total
energy used by the system. You can reset this value to 0 by clicking
Reset at the end of the table row.

–

System Peak Power specifies the system peak value in Watts within
the interval specified by the Measurement Start Time and Measure
Current Time. You can reset this value to 0 by clicking Reset at the
end of the table row.

–

System Peak Amperage specifies the system peak amperage within the
interval specified by the Measurement Start Time and Measure
Current Time. You can reset this value to 0 by clicking Reset at the
end of the table row.

•

Measurement Start Time displays the date and time recorded when the
system energy consumption value was last cleared and the new
measurement cycle began. For Cumulative System Power, System Peak
Amperage, and System Peak Power statistics, you can reset each value to 0
by clicking Reset at the end of the table row; however, it will persist
through a system reset or CMC failover operation.

•

Measurement Current Time for Cumulative System Power displays the
current date and time when the system energy consumption was
calculated for display. For System Peak Amperage and System Peak Power,
the Peak Time fields display the time when these peaks occurred.

•

Reading: The amount of power (in KWh) used since the counter was started.
NOTE: Power Tracking Statistics are maintained across system resets and so reflect
all activity in the interval between the stated Start and Finish Times.The Reset Max
Peaks button will reset to peak statistics value. In the next table, Power Consumption
data is not maintained across system resets and so will reset back to peak statistics
value. The power values displayed are cumulative averages over the respective time
interval (previous minute, hour, day and week). Since the Start to Finish time intervals
here may differ from those of the Power Tracking Statistics ones, peak power values
(Max Peak Watts versus Max Power Consumption) may differ.

Power Monitoring and Power Management

157

Power Consumption

•

Average Power Consumption: Average over previous minute, previous
hour, previous day and previous week.

•

Max Power Consumption and Min Power Consumption: The maximum
and minimum power consumptions observed within the given time interval.

•

Max Power Time and Min Power Time: The times (by minute, hour, day,
and week) when the maximum and minimum power consumptions occurred.

Show Graph

Click Show Graph to display graphs illustrating iDRAC6 power consumption
in Watts over the last hour, 24 hours, three days, and one week. Use the
drop-down menu provided above the graph to select the time period.
NOTE: Each data point plotted on the graphs represents the average of readings
over a 5 minute period. As a result, the graphs may not reflect brief fluctuations in
power or current consumption.

Power Budgeting
iDRAC6 can be configured to enforce the minimum and maximum power
threshold limits, as set by the CMC, for the current system configuration.
The Power Budget screen displays these power threshold limits, which cover the
range of AC power consumptions a thresholded system under heavy workload will
present to the datacenter. These limits are not configurable.

Viewing Power Budget
The server provides power budget status overviews of the power subsystem on the
Power Budget Information screen.
Using the Web Interface

NOTE: To perform power management actions, you must have Administrative
privilege.
1 Log in to the iDRAC6 Web-based interface.
2 In the system tree, select System.
3 Click the Power Management tab, and then click Power Budget.
The Power Budget Information screen appears.
158

Power Monitoring and Power Management

The Power Budget Information table displays the minimum and maximum
limits of power thresholds for the current system configuration. These cover
the range of AC power consumptions a thresholded system under heavy
workload will present to the datacenter.
•

Minimum Potential Power Consumption represents the lowest Power
Budget Threshold value.

•

Maximum Potential Power Consumption represents the highest Power
Budget Threshold value. This value is also the current system
configuration's absolute maximum power consumption.

Using RACADM

On a Managed Node, open a command line interface and enter:
racadm getconfig -g cfgServerPower
NOTE: For more information about cfgServerPower, including output details,
see "cfgServerPower."

Viewing Power Budget Threshold
Power Budget Threshold, if enabled, enforces power limits for the system.
System performance is dynamically adjusted to maintain power consumption
near the specified threshold.
NOTE: Power budget threshold is read-only and cannot be enabled or configured
in iDRAC6.
Actual power consumption may be less for light workloads and momentarily
exceed the threshold until performance adjustments have completed.
Using the Web-Based Interface

1 Log in to the iDRAC6 Web-based interface.
2 In the system tree, select System.
3 Click the Power Management tab, and then click Power Budget.
The Power Budget Information screen appears.
4 Click Power Budget Threshold.

Power Monitoring and Power Management

159

The Power Budget Threshold table displays the power limit information for
the system:
•

Enabled indicates whether the system enforces the power budget threshold.

•

Threshold in Watts and Threshold in BTU/hr display the limit in Watts
and BTU/hr, respectively.

•

Threshold Percentage displays the percentage of power range.

Using RACADM

On a Managed Node, open a command line interface and enter:
racadm getconfig -g cfgServerPower -o
cfgServerPowerCapWatts 
racadm getconfig -g cfgServerPower -o
cfgServerPowerCapBTUhr 
racadm getconfig -g cfgServerPower -o
cfgServerPowerCapPercent 
NOTE: For more information about cfgServerPower, including output details,
see "cfgServerPower."

Power Control
iDRAC6 enables you to remotely perform a power-on, reset, graceful shutdown,
non-masking interruption (NMI), or power cycle. Use the Power Control screen
to perform an orderly shutdown through the operating system when rebooting and
powering on or off.

Executing Power Control Operations on the Server
NOTE: To perform power management actions, you must have Chassis Control
Administrator privilege.
iDRAC6 enables you to remotely perform a power-on, reset, graceful shutdown,
NMI, or power cycle.
Using the Web Interface

1 Log in to the iDRAC6 Web interface.
2 In the system tree, select System.
160

Power Monitoring and Power Management

3 Click the Power Management tab.
The Power Control screen displays.
4 Select one of the following Power Control Operations by clicking its
radio button:
–

Power On System turns on the server (the equivalent of pressing the
power button when the server power is off). This option is disabled if
the system is already powered on.

–

Power Off System turns off the server. This option is disabled if the
system is already powered off.

–

NMI (Non-Masking Interrupt) generates an NMI to halt system
operation. An NMI sends a high-level interrupt to the operating
system, which causes the system to halt operation to allow for critical
diagnostic or troubleshooting activities.

–

Graceful Shutdown attempts to cleanly shutdown the operating
system, then powers off the system. Graceful shutdown requires an
ACPI (Advanced Configuration and Power Interface)-aware operating
system, which allows for system directed power management.

–

Reset System (warm boot) reboots the system without powering off.
This option is disabled if the system is already powered off.

–

Power Cycle System (cold boot) powers off and then reboots the system.
This option is disabled if the system is already powered off.

5 Click Apply.
A dialog box appears requesting confirmation.
6 Click OK to execute the power management action you selected.
Using RACADM

Open a Managed Node open command line interface text console to the server,
log in, and enter:
racadm serveraction 
where  is powerup, powerdown, powercycle, hardreset,
or powerstatus.
NOTE: For more information about serveraction, including output details,
see "serveraction."

Power Monitoring and Power Management

161

162

Power Monitoring and Power Management

Configuring and Using Serial
Over LAN
Serial Over LAN (SOL) is an IPMI feature that allows a managed server’s text
based console data that would traditionally be sent to the serial I/O port to be
redirected over the iDRAC’s dedicated Out of Band Ethernet management
network. The SOL out-of-band console enables system administrators to
remotely manage the blade server’s text-based console from any location with
network access. Benefits of SOL are as follows:
•

Remotely access operating systems with no timeout.

•

Diagnose host systems on Emergency Management Services (EMS) or
Special Administrator Console (SAC) for Windows or in a Linux shell.

•

View the progress of a blade server during POST and reconfigure the BIOS
setup program (while redirected to a serial port).

Enabling Serial Over LAN in the BIOS
To configure the server for Serial Over LAN, the following configuration steps
are required and will be explained in detail.
1 Configure Serial Over LAN in BIOS (disabled by default)
2 Configure iDRAC6 for Serial over LAN
3 Select a method to initialize Serial Over LAN (SSH, telnet, SOL Proxy, or
IPMI Tool)
4 Configure the OS for SOL

Configuring and Using Serial Over LAN

163

Serial communication is off by default in BIOS. In order to redirect the host
text console data to Serial over LAN, you must enable console redirection via
COM1. To change the BIOS setting, perform the following steps:
1 Boot the managed server.
2 Press  to enter the BIOS setup utility during POST.
3 Scroll down to Serial Communication and press .
In the pop-up window, the serial communication list is presented with the
following options:
•

Off

•

On without console redirection

•

On with console redirection via COM1

Use the arrow keys to navigate between options.
4 Ensure that On with console redirection via COM1 is enabled.
5 Ensure that the Failsafe Baud Rate is identical to SOL baud rate that is
configured on iDRAC. The default value for both the failsafe baud rate
and the iDRAC’s SOL baud rate setting is 115.2 kbps.
6 Enable the Redirection After Boot (the default value is DISABLED).
This option enables BIOS SOL redirection across subsequent reboots.
7 Save the changes and exit.
The managed server reboots.

Configuring Serial Over LAN in the iDRAC6
Web GUI
1 Open the Serial Over LAN Configuration screen by selecting System→
Remote Access→ iDRAC→ Network/Security→ Serial Over LAN.
2 Ensure the Enable Serial Over LAN option is selected (enabled). By
default it is enabled.
3 Update the IPMI SOL baud rate by selecting a data speed from the Baud
Rate drop-down menu. The options are 19.2 kbps, 57.6 kbps, and 115.2
kbps. The default value is 115.2 kbps.
NOTE: Ensure that the SOL baud rate is identical to the Failsafe Baud Rate
that was set in BIOS.

164

Configuring and Using Serial Over LAN

4 Click Apply if you have made any changes.
Table 9-1.

Serial Over LAN Configuration Settings

Setting

Description

Enable Serial
Over LAN

When selected, the checkbox indicates that Serial Over LAN is
enabled.

Baud Rate

Indicates the data speed. Select a data speed of 19.2 kbps, 57.6
kbps, or 115.2 kbps.

Table 9-2.

Serial Over LAN Configuration Buttons

Button

Description

Print

Prints the Serial Over LAN Configuration values that appear on
the screen.

Refresh

Reloads the Serial Over LAN Configuration screen.

Advanced
Settings

Opens the Serial Over LAN Configuration Advanced Settings
screen.

Apply

Supplies any new settings that you make while viewing the Serial
Over LAN Configuration screen.

5 Change the configuration on the Advanced Settings screen, if necessary.
Dell recommends using the default values. Advanced Settings allows you
to adjust SOL performance by changing the Character Accumulate
Interval and Character Send Threshold values. For optimal performance,
use the default settings of 10 milliseconds and 250 characters, respectively.

Configuring and Using Serial Over LAN

165

Table 9-3.

Serial Over LAN Configuration Advanced Settings

Setting

Description

Character
Accumulate
Interval

The typical amount of time iDRAC6 waits before sending a partial
SOL data packet. This parameter is specified in milliseconds and
increments by 10 milliseconds.

Character Send
Threshold

Specifies the number of characters per SOL data packet. As soon
as the number of characters accepted by iDRAC6 is equal to or
greater than the Character Send Threshold value, iDRAC6 starts
transmitting SOL data packets that contain numbers of characters
equal to or less than the Character Send Threshold value. If a
packet contains fewer characters than this value, it is defined to be
a partial SOL data packet.

NOTE: If you change these values to lower values, the console redirection
feature of SOL may experience a reduction in performance. Furthermore,
the SOL session must wait to receive an acknowledgement for each packet
before sending the next packet. As a result, the performance is
significantly reduced.
Table 9-4.

Serial Over LAN Configuration Advanced Settings Buttons

Button

Description

Print

Prints the Serial Over LAN Configuration Advanced
Settings values that appear on the screen.

Refresh

Reloads the Serial Over LAN Configuration Advanced
Settings screen.

Apply

Saves any new settings that you make while viewing the
Serial Over LAN Configuration Advanced Settings screen.

Go Back To Serial Over Returns the user to the Serial Over LAN Configuration
LAN Configuration
screen.
Page

6 Configure SSH/Telnet for SOL at System→ Remote Access→ iDRAC→
Network/Security→ Services.
NOTE: Each blade server only supports one active SOL session through
SSH or Telnet protocol.

166

Configuring and Using Serial Over LAN

NOTE: SSH protocol is enable by default. Telnet protocol is disabled
by default.

7 Click Services to open the SSH and Telnet Configuration screen.
NOTE: SSH and Telnet programs both provide access on a remote machine.
8 Click Enable on either SSH or Telnet as required.
9 Click Apply.
NOTE: SSH is a recommended method due to better security and
encryption mechanisms.

NOTE: SSH/Telnet session duration can be infinite as long as the timeout
value is set to 0. The default timeout value is 1800 seconds.

10 Enable iDRAC6 Out-of-Band interface (IPMI over LAN) by selecting
System→ Remote Access→ iDRAC→ Network/Security→ Network.
11 Enable the IPMI Over LAN option under IPMI LAN Settings.
IPMI Over LAN functionality is disabled by default.
12 Click Apply.

Using Serial Over LAN (SOL)
This section provides several methods to initialize a Serial-Over-LAN session
including a Telnet program, an SSH client, IPMItool, and SOL Proxy.
The purpose of Serial Over LAN feature is to redirect the serial port of the
managed server through iDRAC6 into the console of your management station.

Model for Redirecting SOL Over Telnet or SSH
Telnet (port 23)/ SSH (port 22) client ←→ WAN connection ←→
iDRAC6 server
The IPMI-based SOL over SSH/Telnet implementation eliminates the need for
an additional utility because the serial to network translation happens within the
iDRAC. The SSH or Telnet console that you use should be able to interpret and
respond to the data arriving from the managed server's serial port. The serial port
usually attaches to a shell that emulates an ANSI- or VT100- terminal. The serial
console is automatically redirected to your SSH or Telnet console. The SOL
redirection can then be started from the /system/soll target.
See "Installing Telnet or SSH Clients" for more information about using
Telnet and SSH clients with iDRAC.
Configuring and Using Serial Over LAN

167

Model for the SOL Proxy
Telnet Client (port 623) ←→ WAN connection ←→ SOL Proxy ←→
iDRAC6 server
When the SOL Proxy communicates with the Telnet client on a management
station, it uses the TCP/IP protocol. However, SOL proxy communicates with
the managed server's iDRAC6 over the RMCP/IPMI/SOL protocol, which is a
UDP-based protocol. Therefore if you communicate with your managed
system's iDRAC6 from SOL Proxy over a WAN connection, you may
experience network performance issues. The recommended usage model is to
have the SOL Proxy and the iDRAC6 server on the same LAN. The
management station with the Telnet client can then connect to the SOL
Proxy over a WAN connection. In this usage model, SOL Proxy will function
as desired.

Model for Redirecting SOL Over IPMItool
IPMItool ←→ WAN connection ←→ iDRAC6 server
The IPMI-based SOL utility, IPMItool, uses RMCP+ protocol delivered
using UDP datagrams to port 623. iDRAC6 requires this RMCP+ connection
to be encrypted. The encryption key (KG key) must contains characters of
zero or NULL that can be configured in the iDRAC6 Web GUI or in the
iDRAC6 Configuration Utility. You can also wipe out the encryption key by
pressing the backspace key so that iDRAC6 will provide NULL characters as
the encryption key by default. The advantage of using RMCP+ is improved
authentication, data integrity checks, encryption, and the ability to carry
multiple types of payloads. See "Using SOL over IPMItool" or the IPMItool
website for more information: http://ipmitool.sourceforge.net/
manpage.html.

Disconnecting SOL session in SM-CLP
When using SSH or Telnet protocols to access the Serial Over LAN
functionality, you first will be first connecting into the iDRAC’s SM-CLP
service, from which you will launch the SOL session with an SM-CLP
command (start /system1/sol1). Thus, users wanting to disconnect
an SOL session must first terminate the SOL session from SM-CLP.
Commands to disconnect a SOL session are utility oriented. Read this section
carefully. Only when a SOL session is terminated fully can you exit the utility.

168

Configuring and Using Serial Over LAN

When you are ready to quit SOL redirection from SM-CLP, press ,
, and then  (press the keys in sequence, one after the other).
The SOL session will close.
NOTE: If a SOL session is not closed successfully in the utility, more SOL sessions
may not be available. The way to resolve this situation is to delete the SMASH
console in the Web GUI under System→Remote Access→iDRAC→ Network/
Security→Sessions.

Using SOL over PuTTY
To start SOL from PuTTY on a Windows management station, follow
these steps:
NOTE: If required, you can change the default SSH/telnet timeout at System→
Remote Access→ iDRAC → Network/Security → Services.
1 Connect to iDRAC6 with the following command in the command
prompt:
putty.exe [-ssh | -telnet] @ 
NOTE: The port number is optional. It is required only when the port number is
reassigned.

2 Enter the following command in the SM-CLP prompt to start SOL:
start /system1/sol1
NOTE: This connects you to the managed server's serial port. The SM-CLP
commands are no longer available to you. You cannot return to SM-CLP once
you have started SOL. You must quit the SOL session using the command
sequence detailed in "Disconnecting SOL session in SM-CLP," and start a new
one to use SM-CLP.

Configuring and Using Serial Over LAN

169

Using SOL over Telnet with Linux
To start SOL from Telnet on a Linux management station, follow these steps:
NOTE: If required, you can change the default Telnet timeout at System→ Remote
Access→ iDRAC→ Network/Security→ Services.
1 Start a shell.
2 Connect to iDRAC6 with the following command:
telnet 
NOTE: If you have changed the port number for the Telnet service from the
default (port 23), add the port number to the end of the telnet command.

3 Input iDRAC's username and password in order to connect to iDRAC6
SM-CLP.
4 Enter the following command in the SM-CLP prompt to start SOL:
start /system1/sol1
5 To quit a SOL session from Telnet on Linux, press +] (hold down
the control key, press the right-square-bracket key, and then release).
A telnet prompt displays. Enter quit to exit telnet.

Using SOL over OpenSSH with Linux
OpenSSH is an open source utility for using the SSH protocol. To start SOL
from OpenSSH on a Linux management station, follow these steps:
NOTE: If required, you can change the default SSH session timeout at System→
Remote Access→ iDRAC→ Network/Security→ Services.
1 Start a shell.
2 Connect to iDRAC6 with the following command:
ssh  -l 
3 Enter the following command in the SM-CLP prompt to start SOL:
start /system1/sol1
NOTE: This connects you to the managed server's serial port. The SM-CLP
commands are no longer available to you. You cannot return to SM-CLP once
you have started SOL. You must quit the SOL session (refer to "Disconnecting
SOL session in SM-CLP" to close an active SOL session), and start a new one
to use SM-CLP.

170

Configuring and Using Serial Over LAN

Using SOL over IPMItool
The Dell Systems Management Tools and Documentation DVD provides
IPMItool, which can be installed on various operating systems. To start SOL
with IPMItool on a management station, follow these steps:
NOTE: If required, you can change the default SOL timeout at System→ Remote
Access→ iDRAC→ Network/Security→ Services.
1 Locate IPMItool.exe under the proper directory.
The default path in Windows is C:\Program Files\Dell\SysMgt\bmc.
2 Ensure the Encryption Key is all zeroes at System→ Remote Access→
iDRAC→ Network/Security→ Network→ IPMI LAN Settings.
3 Enter the following command in the Windows command prompt or in the
Linux shell prompt to start SOL from iDRAC:
ipmitool -H  -I lanplus -U
 -P  sol activate
This connects you to the managed server's serial port.
4 To quit a SOL session from IPMItool, press <~> and <.> (press the tilde
and period keys in sequence, one after the other). The SOL session will close.
NOTE: If a user does not terminate the SOL session correctly, enter the
following command to reboot iDRAC. Allow iDRAC6 1-2 minutes to complete
booting. See "RACADM Subcommand Overview" for more details.

racadm racreset

Opening SOL with SOL proxy
Serial-Over-LAN Proxy (SOL Proxy) is a telnet daemon that allows
LAN-based administration of remote systems using the Serial over LAN
(SOL) and IPMI protocols. Any standard telnet client application, such as
HyperTerminal on Microsoft Windows or telnet on Linux, can be used to
access the daemon's features. SOL can be used either in the menu mode or
command mode. The SOL protocol coupled with the remote system's BIOS
console redirection allows administrators to remotely view and change a
managed system's BIOS settings over a LAN. The Linux serial console and
Microsoft's EMS/SAC interfaces can also be accessed over a LAN using SOL.

Configuring and Using Serial Over LAN

171

NOTE: All versions of the Windows operating system include HyperTerminal
terminal emulation software. However, the included version does not provide many
functions required during console redirection. Instead, you can use any terminal
emulation software that supports VT100 or ANSI emulation mode. One example of a
full VT100 or ANSI terminal emulator that supports console redirection on your
system is HyperTerminal Private Edition 6.1 or later.
NOTE: See your system's User's Guide for more information about console
redirection, including hardware and software requirements and instructions for
configuring host and client systems to use console redirection.
NOTE: HyperTerminal and telnet settings must be consistent with the settings on the
managed system. For example, the baud rates and terminal modes should match.
NOTE: The Windows telnet command that is run from a MS-DOS® prompt
supports ANSI terminal emulation, and the BIOS needs to be set for ANSI emulation
to display all the screens correctly.

Before Using SOL proxy

Before using SOL proxy, see the Baseboard Management Controller Utilities
User's Guide to learn how to configure your management stations before
using SOL proxy. By default, BMC Management Utility is installed in the
following directory on Windows operating systems:
C:\Program Files\Dell\SysMgt\bmc
The installation program copies the files to the following locations on Linux
Enterprise Operating Systems:
/etc/init.d/SOLPROXY.cfg
/etc/SOLPROXY.cfg
/usr/sbin/dsm_bmu_solproxy32d
/usr/sbin/solconfig
/usr/sbin/ipmish

172

Configuring and Using Serial Over LAN

Initiating the SOL Proxy session
For Windows 2003

To start the SOL Proxy service on Windows system after installation, you can
reboot the system (SOL Proxy automatically starts on a reboot). Or, you can
start the SOL Proxy service manually by completing the following steps:
1 Right-click My Computer and click Manage.
The Computer Management window is displayed.
2 Click Services and Applications and then click Services.
Available services are displayed to the right.
3 Locate DSM_BMU_SOLProxy in the list of services and right-click to
start the service.
Depending on the console you use, there are different steps for accessing SOL
Proxy. Throughout this section, the management station where the SOL
Proxy is running is referred as the SOL Proxy Server.
For Linux

The SOL Proxy will start automatically during system startup. Alternatively,
you can go to directory /etc/init.d and use the following commands to
manage the SOL Proxy service:
solproxy status
dsm_bmu_solproxy32d start
dsm_bmu_solproxy32d stop
solproxy restart

Configuring and Using Serial Over LAN

173

Using Telnet with SOL Proxy

This assumes that the SOL Proxy service is already up and running on the
management station.
For Windows 2003:

1 Open a Command Prompt window on your management station.
2 Enter the telnet command in the command-line and provide
localhost as the IP address if the SOL Proxy server is running in the
same machine and the port number that you specified in the SOL Proxy
installation (the default value is 623). For example:
telnet localhost 623
For Linux:

1 Open a Linux shell on your management station.
2 Enter the telnet command and provide localhost as the IP address
of the SOL Proxy server and the port number that you specified in the
SOL Proxy installation (the default value is 623). For example:
telnet localhost 623
NOTE: Whether your host operating system is Windows or Linux, if the SOL Proxy
server is running on a different machine than your management station, input SOL
Proxy server IP address instead of localhost.
telnet  623
Using HyperTerminal with SOL Proxy

1 From the remote station, open HyperTerminal.exe.
2 Choose TCPIP(Winsock).
3 Enter host address localhost and port number 623.
Connecting to the Remote Managed System's BMC

After a SOL Proxy session is established successfully, you are presented with
the following choices:
1. Connect to the Remote Server's BMC
2. Configure the Serial-Over-LAN for the Remote
Server
174

Configuring and Using Serial Over LAN

3. Activate Console Redirection
4. Reboot and Activate Console Redirection
5. Help
6. Exit
NOTE: While multiple SOL sessions can be active at the same time, only one
console redirection session can be active at any given time for a managed system.
NOTE: To exit an active SOL session, use the <~><.> character sequence.
This sequence terminates SOL and returns you to the top-level menu.
1 Select option 1 in the main menu.
2 Enter the iDRAC IP Address of the remote managed system.
3 Provide the iDRAC6 Username and Password for iDRAC6 on the managed
system. The iDRAC6 username and password must be assigned and stored
in the iDRAC6 non-volatile storage.
NOTE: Only one SOL console redirection session with iDRAC6 is permitted at
one time.

NOTE: If required, extend SOL session duration to infinite by changing the
Telnet timeout value to zero in the iDRAC6 Web GUI under System→ Remote
Access→ iDRAC→ Network/Security→ Services.

4 Provide the IPMI encryption key if it was configured in the iDRAC.
NOTE: You can locate the IPMI encryption key in the iDRAC6 GUI on
System→ Remote Access→ iDRAC→ Network/Security→ Network→ IPMI
LAN Settings→ Encryption Key.

NOTE: The default IPMI encryption key is all zeros. If you press  for
the encryption option, iDRAC6 will use this default encryption key.

Configuring and Using Serial Over LAN

175

5 Select Configure the Serial-Over-LAN for the Remote Server (option 2)
in the main menu.
The SOL configuration menu appears. According to the current SOL
status, the content of the SOL configuration menu varies:
•

If SOL is already enabled, the current settings are displayed and you
are presented with three choices:
1. Disable Serial-Over-LAN
2. Change Serial-Over-LAN settings
3. Cancel

•

If SOL is enabled, ensure that the SOL baud rate is consistent with
the iDRAC's and the minimum iDRAC6 user privilege level of
administrator is required for activating console redirection.

•

If SOL is currently disabled, enter Y to enable SOL or N to keep
SOL disabled.

6 Select Activate Console Redirection (option 3) in the main menu
The remote managed system's text console is redirected to your
management station.
7 Select Reboot and Activate Console Redirection (option 4) in the main
menu (optional).
The power state of the remote managed system is confirmed. If power is
on, you are asked to decide between a graceful or forceful shutdown.
The power state is monitored until the state changes to On. Console
redirection begins, and the remote managed system text console is
redirected to your management station.
While the managed system reboots, you can enter BIOS system setup
program to view or configure BIOS settings.
8 Select Help (option 5) in the main menu to display a detailed description
for each option.
9 Select Exit (option 6) in the main menu to end your telnet session and
disconnect from SOL Proxy.
NOTE: If a user does not terminate the SOL session correctly, issue the
following command to reboot iDRAC. Allow iDRAC6 1-2 minutes to complete
booting. Refer to "RACADM Subcommand Overview" for more details.

racadm racreset
176

Configuring and Using Serial Over LAN

Operating System Configuration
Complete the steps below to configure generic Unix-like operating systems.
This configuration is based on default installations of Red Hat Enterprise Linux
5.0, SUSE Linux Enterprise Server 10 SP1, and Windows 2003 Enterprise.

Linux Enterprise Operating System
1 Edit the /etc/inittab file to enable hardware flow control and to allow users
to log in through the SOL console. Add the line below to the end of #Run
gettys in standard runlevels section.
7:2345:respawn:/sbin/agetty -h 115200 ttyS0 vt220
Example of original /etc/inittab:
______________________________________________________________
#
# inittab

This file describes how the INIT process should set up

#

the system in a certain run-level.

#
SKIP this part of file
# Run gettys in standard runlevels
1:2345:respawn:/sbin/migetty tty1
2:2345:respawn:/sbin/migetty tty1
3:2345:respawn:/sbin/migetty tty1
4:2345:respawn:/sbin/migetty tty1
5:2345:respawn:/sbin/migetty tty1
6:2345:respawn:/sbin/migetty tty1
# Run xdm in runlevel 5
x:5:respawn:/etc/X11/prefdm -nodaemon

______________________________________________________________

Configuring and Using Serial Over LAN

177

Example of modified /etc/inittab:
______________________________________________________________
#
# inittab

This file describes how the INIT process should set up

#

the system in a certain run-level.

#
SKIP this part of file
# Run gettys in standard runlevels
1:2345:respawn:/sbin/migetty tty1
2:2345:respawn:/sbin/migetty tty1
3:2345:respawn:/sbin/migetty tty1
4:2345:respawn:/sbin/migetty tty1
5:2345:respawn:/sbin/migetty tty1
6:2345:respawn:/sbin/migetty tty1
7:2345:respawn:/sbin/agetty -h ttyS0 115200 vt220
# Run xdm in runlevel 5
x:5:respawn:/etc/X11/prefdm -nodaemon

______________________________________________________________
2 Edit the /etc/securetty file to allow users to log in as root user through
the SOL console. Add the following line after console:
ttyS0

Example of original /etc/securetty:
______________________________________________________________
console
vc/1
vc/2
vc/3
vc/4

SKIP the rest of file

______________________________________________________________
178

Configuring and Using Serial Over LAN

Example of modified /etc/securetty:
______________________________________________________________
Console
ttyS0
vc/1
vc/2
vc/3
vc/4
SKIP the rest of file

______________________________________________________________
3 Edit the /boot/grub/grub.conf or /boot/grub/menu.list file to add boot
options for SOL:
a

b

Comment out the graphical display lines in the various Unix-like
operating systems:
•

splashimage=(had0,0)/grub/splash.xpm.gz in
RHEL 5

•

gfxmenu (hda0,5)/boot/message in SLES 10

Add the following line before the first title= … line:

# Redirect OS boot via SOL
c

Append the following entry to the first title= … line:

SOL redirection
d

Append the following text to the kernel/… line of the first title=
…:

console=tty1 console=ttyS0,115200
NOTE: /boot/grub/grub.conf in Red Hat Enterprise Linux 5 is a symbolic link to /
boot/grub/menu.list. You can change the settings in either one of them.

Configuring and Using Serial Over LAN

179

Example of original /boot/grub/grub.conf in RHEL 5:
______________________________________________________________
# grub.conf generated by anaconda
#
# Note that you do not have to return grub after making changes
to this
# file
# NOTICE: You have a /boot partition. This means that
#
eg.

all kernel and initrd paths are relative to /boot/,

#

root (hd0,0)

#
LogVol00

kernel /vmlinux-version ro root=/dev/VolGroup00/

#

initrd /initrd-version.img

#boot=/dev/sda
default=0
timeout=5
splashimage=(hd0,0)/grub/splash.xpm/gz
hiddenmenu
title Red Hat Enterprise Linux 5
root (hd0,0)
kernel /vmlinuz-2.6.18-8.el5 ro root=/dev/VolGroup00/
LogVol00 rhgb quiet
initrd /initrd-2.6.18-8.el5.img

______________________________________________________________
Example of modified /boot/grub/grub.conf:
______________________________________________________________
# grub.conf generated by anaconda
#
# Note that you do not have to return grub after making changes
to this
# file
# NOTICE: You have a /boot partition. This means that

180

Configuring and Using Serial Over LAN

#
eg.

all kernel and initrd paths are relative to /boot/,

#

root (hd0,0)

#
LogVol00

kernel /vmlinux-version ro root=/dev/VolGroup00/

#

initrd /initrd-version.img

#boot=/dev/sda
default=0
timeout=5
#splashimage=(hd0,0)/grub/splash.xpm/gz
hiddenmenu
# Redirect the OS boot via SOL
title Red Hat Enterprise Linux 5 SOL redirection
root (hd0,0)
kernel /vmlinuz-2.6.18-8.el5 ro root=/dev/VolGroup00/
LogVol00 rhgb quiet console=tty1 console=ttyS0,115200
initrd /initrd-2.6.18-8.el5.img

______________________________________________________________
Example of original /boot/grub/menu.list in SLES 10:
______________________________________________________________
#Modified by YaST2. Last modification on Sat Oct 11 21:52:09
UTC 2008
Default 0
Timeout 8
gfxmenu (hd0.5)/boot/message
###Don't change this comment - YaST2 identifier: Original name:
linux###
title SUSE Linux Enterprise Server 10 SP1
root (hd0,5)
kernel /boot/vmlinux-2.6.16-46-0.12-bigsmp root=/dev/disk/
by-id/scsi-35000c5000155c resume=/dev/sda5 splash=silent
showopts
initrd /boot/initrd-2.6.16.46-0.12-bigsmp

______________________________________________________________
Configuring and Using Serial Over LAN

181

Example of modified /boot/grub/menu.list in SLES 10:
______________________________________________________________
#Modified by YaST2. Last modification on Sat Oct 11 21:52:09
UTC 2008
Default 0
Timeout 8
#gfxmenu (hd0.5)/boot/message
###Don't change this comment - YaST2 identifier: Original name:
linux###
title SUSE Linux Enterprise Server 10 SP1 SOL redirection
root (hd0,5)
kernel /boot/vmlinux-2.6.16-46-0.12-bigsmp root=/dev/disk/
by-id/scsi-35000c5000155c resume=/dev/sda5 splash=silent
showopts console=tty1 console=ttyS0,115200
initrd /boot/initrd-2.6.16.46-0.12-bigsmp

______________________________________________________________

Windows 2003 Enterprise
1 Find out the boot entry ID by entering bootcfg in the Windows
command prompt. Locate the boot entry ID for the section with the OSfriendly name Windows Server 2003 Enterprise. Press  to display
the boot options on the management station.
2 Enable EMS at a Windows command prompt by entering:
bootcfg /EMS ON /PORT COM1 /BAUD 115200 /ID 
NOTE:  is the boot entry ID from step 1.
3 Press  to verify that the EMS console setting takes effect.

182

Configuring and Using Serial Over LAN

Example of original bootcfg setting:
______________________________________________________________
Boot Loader Settings
-------------------timeout:30
default:multi(0)disk(0)rdisk(0)partition(1)\WINDOWS
Boot Entries
-----------Boot entry ID:

1

Os Friendly Name: Winodws Server 2003, Enterprise
Path:

multi(0)disk(0)rdisk(0)partition(1)\WINDOWS

OS Load Options:
redirect

/nonexecute=optout /fastdetect /usepmtimer /

______________________________________________________________
Example of modified bootcfg setting:
______________________________________________________________
Boot Loader Settings
-------------------timeout:

30

default:

multi(0)disk(0)rdisk(0)partition(1)\WINDOWS

redirect:

COM1

redirectbaudrate:115200
Boot Entries
-----------Boot entry ID:

1

Os Friendly Name: Windows Server 2003, Enterprise
Path:

multi(0)disk(0)rdisk(0)partition(1)\WINDOWS

OS Load Options:
redirect

/nonexecute=optout /fastdetect /usepmtimer /

______________________________________________________________

Configuring and Using Serial Over LAN

183

184

Configuring and Using Serial Over LAN

Using GUI Console Redirection
This section provides information about using the iDRAC6 console
redirection feature.

Overview
The iDRAC6 console redirection feature enables you to remotely access local
consoles in graphic or text mode, allowing you to control one or more
iDRAC6-enabled systems from a single location.

Using Console Redirection
NOTE: When you open a console redirection session, the managed server does not
indicate that the console has been redirected.
The Console Redirection screen enables you to manage the remote system by
using the keyboard, video, and mouse on your local management station to
control the corresponding devices on a remote managed server. This feature
can be used in conjunction with the Virtual Media feature to perform remote
software installations.
The following rules apply to a console redirection session:
•

A maximum of two simultaneous console redirection sessions are supported.
Both sessions view the same managed server console simultaneously.

•

A console redirection session should not be launched from a Web browser
on the managed system.

•

A minimum available network bandwidth of 1 MB/sec is required.

If a second user requests a console redirection session, the first user is notified
and is given the option to refuse access, allow only video, or allow full shared
access. The second user is notified that another user has control. The first
user must respond within thirty seconds or full access is automatically granted
to the second user. During the time that two sessions are concurrently active,
Using GUI Console Redirection

185

each user sees a message in the upper-right corner of the screen that identifies
the other user with an active session. A third active session is not permitted.
If a third user requests a console redirection session, access is denied without
interruption to the first or second user’s session.
If the neither the first or second user has administrator privileges, termination
of the first user's active session automatically results in termination of the
second user's session.

Supported Screen Resolutions and Refresh Rates
Table 10-1 lists the supported screen resolutions and corresponding refresh
rates for a console redirection session that is running on the managed server.
Table 10-1. Supported Screen Resolutions and Refresh Rates
Screen Resolution

Refresh Rate (Hz)

720x400

70

640x480

60, 72, 75, 85

800x600

60, 70, 72, 75, 85

1024x768

60, 70, 72, 75, 85

1280x1024

60

Configuring the Management Station
To use Console Redirection on the management station, perform the
following procedures:
1 Install and configure a supported Web browser. See "Supported Web
Browsers" and "Configuring a Supported Web Browser."
2 If you are using Firefox or want to use the Java Viewer with Internet
Explorer, install a Java Runtime Environment (JRE). See "Installing a Java
Runtime Environment (JRE)."
3 Dell recommends that you configure your monitor display resolution to
1280x1024 pixels.
NOTE: If you have an active console redirection session and a lower resolution
monitor is connected to the iKVM, the server console resolution may reset if the
server is selected on the local console. If the server is running a Linux operating
system, an X11 console may not be viewable on the local monitor.
Pressing  at the iKVM will switch Linux to a text console.
186

Using GUI Console Redirection

Configuring Console Redirection and Virtual Media in the iDRAC6 Web
Interface
To configure console redirection in the iDRAC6 Web interface, perform the
following steps:
1 Click System and then click the Console tab.
2 Click Configuration to open the Console Redirection Configuration screen.
3 Configure the console redirection properties. Table 10-2 describes the
settings for console redirection.
4 When completed, click Apply.
5 Click the appropriate button to continue. See Table 10-3.
Table 10-2.

Console Redirection Configuration Properties

Property

Description

Enabled

Click to enable or disable Console Redirection.
Checked indicates that Console Redirection is enabled.
Unchecked indicates that Console Redirection is disabled.
The default is enabled.

Max Sessions

Displays the maximum number of Console Redirection
sessions that are possible, 1 or 2. Use the drop-down
menu to change the maximum number of Console
Redirection sessions allowed. The default is 2.

Active Sessions

Displays the number of Active Console sessions.
This field is read-only.

Keyboard and Mouse Port The network port number used for connecting to the
Number
Console Redirection Keyboard/Mouse option.
This traffic is always encrypted. You may need to change
this number if another program is using the default port.
The default is 5900.
Video Port Number

The network port number used for connecting to the
Console Redirection Screen service. You may need to
change this setting if another program is using the
default port. The default is 5901.

Using GUI Console Redirection

187

Table 10-2. Console Redirection Configuration Properties (continued)
Property

Description

Video Encryption Enabled Checked indicates that video encryption is enabled.
All traffic going to the video port is encrypted.
Unchecked indicates that video encryption is disabled.
Traffic going to the video port is not encrypted.
The default is Encrypted. Disabling encryption can
improve performance on slower networks.
Mouse Mode

Choose Windows if the managed server is running on a
Windows operating system.
Choose Linux if your server is running on Linux.
Choose No Access if your server is not running on a
Windows or Linux operating system.

NOTE: You must select No Access Mouse Mode in
HyperV, Dell Diagnostics, or USC.
The default is Windows.
Console Plug-In Type for IE When using Internet Explorer on a Windows operating
system, you can choose from the following viewers:
ActiveX - The ActiveX Console Redirection viewer
Java - Java Console Redirection viewer

NOTE: Depending on your version of Internet Explorer,
additional security restrictions may need to be turned off
(see "Configuring and Using Virtual Media").

NOTE: You must have the Java runtime environment
installed on your client system to use the Java viewer.
Local Server Video
Enabled

Checked indicates that output to the iKVM monitor is
enabled during console redirection. Unchecked
indicates that the tasks you perform using Console
Redirection will not be visible on the managed server’s
local monitor.

NOTE: For information about using Virtual Media with Console Redirection, see
"Configuring and Using Virtual Media."

188

Using GUI Console Redirection

The buttons in Table 10-5 are available on the Console Redirection
Configuration screen.
Table 10-3.

Console Redirection Configuration Buttons

Button

Definition

Print

Prints the Console Redirection Configuration screen

Refresh

Reloads the Console Redirection Configuration screen

Apply

Saves any new settings made to the console redirection

Opening a Console Redirection Session
When you open a console redirection session, the Dell Virtual KVM Viewer
Application starts and the remote system’s desktop appears in the viewer.
Using the Virtual KVM Viewer Application, you can control the remote
system’s mouse and keyboard functions from your local management station.
To open a console redirection session in the Web interface, perform the
following steps:
1 Click System and then click the Console tab.
2 In the Console Redirection screen, use the information in Table 10-4 to
ensure that a console redirection session is available.
If you wish to reconfigure any of the property values displayed,
see "Configuring Console Redirection and Virtual Media in the iDRAC6
Web Interface."
Table 10-4.

Console Redirection Information

Property

Description

Console Redirection
Enabled

Yes/No

Video Encryption Enabled Yes/No
Max Sessions

Displays the maximum number of supported Console
Redirection sessions.

Current Sessions

Displays the current number of active console
redirection sessions.

Using GUI Console Redirection

189

Table 10-4. Console Redirection Information (continued)
Property

Description

Mouse Mode

Displays the mouse acceleration currently in effect.
Mouse Acceleration mode should be chosen based on
the type of operating system installed on the managed
server.

Console Plug-in Type

Shows the plug-in type currently configured.
ActiveX — An Active-X viewer will be launched.
Active-X viewer will only work on Internet Explorer
while running on a Windows Operating System.
Java — A Java viewer will be launched. The Java viewer
can be used on any browser including Internet Explorer.
If your client runs on an operating system other than
Windows, then you must use the Java Viewer. If you are
accessing iDRAC6 using Internet Explorer while
running on a Windows operating system, you may
choose either Active-X or Java as the plug-in type.

Local Server Video
Enabled

Checked indicates that output to the iKVM monitor is
enabled during console redirection. Unchecked ensures
that the tasks you perform using Console Redirection
will not be visible on the managed server’s local monitor.

NOTE: For information about using Virtual Media with Console Redirection,
see "Configuring and Using Virtual Media."
The buttons in Table 10-5 are available on the Console Redirection screen.
Table 10-5. Console Redirection Buttons
Button

Definition

Refresh

Reloads the Console Redirection Configuration screen

Launch Viewer

Opens a console redirection session on the targeted
remote system

Print

Prints the Console Redirection Configuration screen

190

Using GUI Console Redirection

3 If a console redirection session is available, click Launch Viewer.
NOTE: Multiple message boxes may appear after you launch the application.
To prevent unauthorized access to the application, you must navigate through
these message boxes within three minutes. Otherwise, you will be prompted
to relaunch the application.

NOTE: If one or more Security Alert windows appear in the following steps,
read the information in the window and click Yes to continue.

The management station connects to iDRAC6 and the remote system’s
desktop appears in the Dell Digital KVM Viewer Application.
4 Two mouse pointers appear in the viewer window: one for the remote
system and one for your local system. You must synchronize the two mouse
pointers so that the remote mouse pointer follows your local mouse
pointer. See "Synchronizing the Mouse Pointers."

Using the Video Viewer
The Video Viewer provides a user interface between the management station
and the managed server, allowing you to see the managed server’s desktop and
control its mouse and keyboard functions from your management station.
When you connect to the remote system, the Video Viewer starts in a
separate window.
The Video Viewer provides various control adjustments such as color mode,
mouse synchronization, snapshots, keyboard macros, and access to Virtual
Media. Click Help for more information on these functions.
When you start a console redirection session and the Video Viewer appears,
you may need to adjust the color mode and synchronize the mouse pointers.
Table 10-6 describes the menu options that are available for use in the viewer.

Using GUI Console Redirection

191

Table 10-6. Viewer Menu Bar Selections
Menu Item

Item

Description

Video

Pause

Temporarily pauses console redirection.

Resume

Resumes console redirection.

Refresh

Redraws the viewer screen image.

Capture
Captures the current remote system screen to a .bmp
Current Screen file on Windows or a .png file on Linux. A dialog box
is displayed that allows you to save the file to a
specified location.

Keyboard

Full Screen

To make the Video Viewer expand into full screen
mode, select Full Screen from the Video menu.

Exit

When you have finished using the Console and have
logged out (using the remote system's logout
procedure), select Exit from the Video menu to close
the Video Viewer window.

Hold Right Alt Select this item before typing keys you want to
Key
combine with the right  key.
Hold Left Alt
Key

Select this item before typing keys you want to
combine with the left  key.

Left Windows
Key

Select Hold Down before typing characters you want
to combine with the left Windows key. Select Press
and Release to send a left Windows key keystroke.

Right Windows Select Hold Down before typing characters you want
Key
to combine with the right Windows key. Select Press
and Release to send a right Windows key keystroke.

192

Using GUI Console Redirection

Table 10-6.
Menu Item

Viewer Menu Bar Selections (continued)
Item

Description

Macros

When you select a macro, or enter the hotkey
specified for the macro, the action is executed on the
remote system. The Video Viewer provides the
following macros:
• Ctrl-Alt-Del
• Alt-Tab
• Alt-Esc
• Ctrl-Esc
• Alt-Space
• Alt-Enter
• Alt-Hyphen
• Alt-F4
• PrtScn
• Alt-PrtScn
• F1
• Pause
• Alt+m

Mouse

Options

Keyboard
Pass-through

The Keyboard pass-through mode allows all keyboard
functions on the client to be redirected to the server.

Synchronize
Cursor

Synchronizes the cursor so that the mouse on the
client is redirected to the mouse on the server.

Hide Local
Cursor

Only the cursor from the KVM will be displayed.
Dell recommends this setting when running USC in
a vKVM.

Color Mode

Allows you to select a color depth to improve
performance over the network. For example, if you are
installing software from virtual media, you can choose
the lowest color depth (3-bit gray), so that less network
bandwidth is used by the console viewer leaving more
bandwidth for transferring data from the media.
The color mode can be set to 15-bit color, 7-bit color,
4-bit color, 4-bit gray, and 3-bit gray.

Using GUI Console Redirection

193

Table 10-6. Viewer Menu Bar Selections (continued)
Menu Item

Item

Description

Media

Virtual Media
Wizard

The Media menu provides access to the Virtual
Media Wizard, which allows you to redirect to a
device or image such as a:
• Floppy drive
• CD
• DVD
• Image in ISO format
• USB Flash drive
For information about the Virtual Media feature,
see "Configuring and Using Virtual Media."
You must keep the Console Viewer window active
when using Virtual Media.

Help

N/A

Activates the Help menu.

Synchronizing the Mouse Pointers
When you connect to a remote PowerEdge system using Console
Redirection, the mouse acceleration speed on the remote system may not
synchronize with the mouse pointer on your management station, causing
two mouse pointers to appear in the Video Viewer window.
To synchronize the mouse pointers click Mouse→ Synchronize cursor or
press .
The Synchronize cursor menu item is a toggle. Ensure that there is a check
mark next to the item in the menu so that the mouse synchronization is active.
When using Red Hat Enterprise Linux or Novell SUSE Linux, be sure to
configure the mouse mode for Linux before you launch the viewer. See
"Configuring Console Redirection and Virtual Media in the iDRAC6 Web
Interface" for help with configuration. The operating system’s default mouse
settings are used to control the mouse arrow in the iDRAC6 Console
Redirection screen.

194

Using GUI Console Redirection

Disabling or Enabling Local Console
You can configure iDRAC6 to disallow iKVM connections using the iDRAC6
Web interface. When the local console is disabled, a yellow status dot appears
in the list of servers (OSCAR) to indicate that the console is locked in
iDRAC6. When the local console is enabled, the status dot is green.
If you want to ensure that you have exclusive access to the managed server
console, you must disable the local console and reconfigure the Max Sessions
to 1 on the Console Redirection screen.
NOTE: The local console feature is supported on all x9xx PowerEdge systems
except PowerEdge SC1435 and 6950.
NOTE: By disabling (turning off) the local video on the server, the monitor,
keyboard, and mouse connected to the iKVM are disabled.
To disable or enable the local console, perform the following procedure:
1 On your management station, open a supported Web browser and log in to
iDRAC6. See "Accessing the Web Interface" for more information.
2 Click System, click the Console tab, and then click Configuration.
3 If you want to disable (turn off) local video on the server, in the Console
Redirect Configuration screen, uncheck Local Server Video Enabled and
then click Apply. The default value is Enabled (checked).
4 If you want to enable (turn on) local video on the server, in the Console
Redirect Configuration screen, check Local Server Video Enabled and
then click Apply.
The Console Redirection screen displays the status of the Local Server Video.

Using GUI Console Redirection

195

Frequently Asked Questions
Table 10-7 lists frequently asked questions and answers.
Table 10-7. Using Console Redirection: Frequently Asked Questions
Question

Answer

Can a new remote
console video session
be started when the
local video on the
server is turned off?

Yes.

Why does it take
It gives a local user an opportunity to take any action before
15 seconds to turn off the video is switched off.
the local video on the
server after requesting
to turn off the local
video?
Is there a time delay
when turning on the
local video?

No, once a local video turn ON request is received by
iDRAC6 the video is turned on instantly.

Can the local user also Yes, a local user can use the local RACADM CLI to turn off
turn off the video?
the video.
Can the local user also No. Once the local console is disabled, the local user’s
turn on the video?
keyboard and mouse are disabled and they are unable to
change any settings.
Does switching off the Yes.
local video also switch
off the local keyboard
and mouse?
Does turning off the
local console turn off
the video on the
remote console
session?

196

No, turning the local video on or off is independent of the
remote console session.

Using GUI Console Redirection

Table 10-7.

Using Console Redirection: Frequently Asked Questions (continued)

Question

Answer

What privileges are
Any user with iDRAC6 configuration privileges can turn the
needed for an iDRAC6 local console on or off.
user to turn on or off
the local server video?
How can I get the
current status of the
local server video?

The status is displayed on the Console Redirection
Configuration screen of the iDRAC6 Web interface.
The RACADM CLI command racadm getconfig –g
cfgRacTuning displays the status in the object
cfgRacTuneLocalServerVideo.
The status is also seen on the iKVM OSCAR display. When
the local console is enabled, a green status appears next to
the server name. When disabled, a yellow dot indicates that
the local console is locked by iDRAC6.

I cannot see the
bottom of the system
screen from the
Console Redirection
window.

Ensure that the management station’s monitor resolution is
set to 1280x1024.

The console window is The console viewer on Linux requires a UTF-8 character set.
garbled.
Check your locale and reset the character set if needed.
See "Setting the Locale in Linux" for more information.
Why do I get a blank
screen on the
managed server when
loading the
Windows 2000
operating system?

The managed server does not have the correct ATI video
driver. You must update the video driver by using the
Dell PowerEdge Installation and Server Management CD.

Using GUI Console Redirection

197

Table 10-7. Using Console Redirection: Frequently Asked Questions (continued)
Question

Answer

Why doesn’t the
mouse sync in DOS
when performing
Console Redirection?

The Dell BIOS is emulating the mouse driver as a PS/2
mouse. By design, the PS/2 mouse uses relative position for
the mouse pointer, which causes the lag in syncing. iDRAC6
has a USB mouse driver, which allows absolute position and
closer tracking of the mouse pointer. Even if iDRAC6 passes
the USB absolute mouse position to the Dell BIOS, the BIOS
emulation would convert it back to relative position and the
behavior would remain. To fix this problem, set the mouse
mode to No Access in the Console Redirection
configuration.

Why doesn’t the
Virtual KVM requires the USB mouse driver, but the USB
mouse sync under the mouse driver is available only under the X-Window operating
Linux text console?
system.
I am still having issues Ensure that the correct mouse is selected for your operating
with mouse
system before starting a console redirection session.
synchronization.
Ensure that Synchronize Mouse is checked in the Mouse
menu. Press  or select Mouse→ Synchronize
mouse to toggle mouse synchronization. When
synchronization is enabled, a check mark appears next to the
selection in the Mouse menu.
Why can't I use a
keyboard or mouse
while installing a
Microsoft® operating
system remotely by
using iDRAC6
Console Redirection?

When you remotely install a supported Microsoft operating
system on a system with Console Redirection enabled in the
BIOS, you receive an EMS Connection Message that requires
that you select OK before you can continue. You cannot use
the mouse to select OK remotely. You must either select OK
on the local system or restart the remotely managed server,
reinstall, and then turn Console Redirection off in the BIOS.
This message is generated by Microsoft to alert the user that
Console Redirection is enabled. To ensure that this message
does not appear, always turn off Console Redirection in the
BIOS before installing an operating system remotely.

198

Using GUI Console Redirection

Table 10-7.

Using Console Redirection: Frequently Asked Questions (continued)

Question

Answer

Why doesn’t the Num
Lock indicator on my
management station
reflect the status of
the Num Lock on the
remote server?

When accessed through iDRAC6, the Num Lock indicator
on the management station does not necessarily coincide
with the state of the Num Lock on the remote server. The
state of the Num Lock is dependent on the setting on the
remote server when the remote session is connected,
regardless of the state of the Num Lock on the management
station.

Why do multiple
You are configuring a console redirection session from the
Session Viewer
local system. This is not supported.
windows appear when
I establish a console
redirection session
from the local host?
If I am running a
No. If a local user accesses the system, you both have control
console redirection
of the system.
session and a local user
accesses the managed
server, do I receive a
warning message?
How much bandwidth Dell recommends a 5 MB/sec connection for good
do I need to run a
performance. A 1 MB/sec connection is required for minimal
console redirection
performance.
session?
What are the
minimum system
requirements for my
management station
to run console
redirection?

The management station requires an Intel Pentium III
500 MHz processor with at least 256 MB of RAM.

Using GUI Console Redirection

199

200

Using GUI Console Redirection

Configuring a VFlash Media Card for
Use With iDRAC6
The VFlash media card is a Secure Digital (SD) card that plugs into the
optional iDRAC6 Enterprise card slot at the back corner of the system.
It provides storage space that behaves like a common USB Flash Key device.

Installing a VFlash Media Card
NOTE: Dell-branded vFlash media is required for the virtual flash partition.
1 Remove the blade from the chassis.
2 Locate the VFlash media slot at the back corner of the system.
NOTE: You do not need to remove the blade cover to install or remove
the card.

Configuring a VFlash Media Card for Use With iDRAC6

201

3 With the label side facing up, insert the contact-pin end of the SD card
into the card slot on the module.
NOTE: The slot is keyed to ensure correct insertion of the card.
4 Press inward on the card to lock it into the slot.
5 Place the blade back in the chassis.

Removing a VFlash Media Card
To remove the VFlash media, push inward on the card to release it, and pull
the card from the card slot.

Configuring the VFlash Media Card Using the
iDRAC6 Web Interface
Enabling or Disabling the VFlash Media Card
NOTE: The VFlash Enable check box is active only if a VFlash card is present.
If card is not present, the following message displays:
SD Card not inserted. Please insert an SD card of
size greater than 256MB.
1 Ensure that the VFlash card has been installed.
2 Open a supported Web browser window.
3 Log in to the iDRAC6 Web interface.
4 In the system tree, select System.
5 Click the VFlash tab.
The VFlash screen appears.
6 Select the Enable VFlash check box to enable the VFlash Media Card.
To disable, deselect the check box.
7 Click Apply.

202

Configuring a VFlash Media Card for Use With iDRAC6

Formatting the VFlash Media Card
NOTE: The Format option is active only if a VFlash card is present.
1 Log in to the iDRAC6 Web interface.
2 In the system tree, select System.
3 Click the VFlash tab.
The VFlash screen appears.
4 Ensure that VFlash is disabled. The VFlash Enable check box should be
cleared (unchecked).
5 Click Format.
An alert box appears, warning that any existing image on the card will be
erased during formatting and requesting confirmation. Click OK to continue.
A status bar appears, indicating formatting progress.

Uploading Disk Image
1 Ensure the image file has the extension .img and that the image is not
larger than 256 MB.
NOTE: Though your VFlash card may be larger than 256 MB, only 256 MB is
accessible at this time.

2 Log in to the iDRAC6 Web interface.
3 In the system tree, select System.
4 Click the VFlash tab.
The VFlash screen appears.
5 Ensure that VFlash is disabled. The VFlash Enable check box should be
cleared (unchecked).
6 In the VFlash Drive section, enter the path to the image file or click
Browse to navigate to its location on your system.
Click Upload.
A status bar appears, indicating upload progress.

Viewing the VFlash Key Size
The Virtual Flash Key Size drop-down menu displays the current size setting.
Configuring a VFlash Media Card for Use With iDRAC6

203

Configuring the VFlash Media Card Using
RACADM
Enabling or Disabling the VFlash Media Card
Open a local console to the server, log in, and enter:
racadm cfgRacVirtual cfgVirMediaKeyEnable [ 1 or 0 ]
where 1 is enabled and 0 is disabled.
NOTE: For more information about cfgRacVirtual, including output details, see
"cfgRacVirtual."

Formatting the VFlash Media Card
Open a Telnet/SSH text console to the server, log in, and enter:
racadm vmkey reset
CAUTION: Formatting the VFlash media card deletes all existing data.
NOTE: For more information about vmkey, see "vmkey."

204

Configuring a VFlash Media Card for Use With iDRAC6

Configuring and Using Virtual Media
Overview
The Virtual Media feature, accessed through the console redirection viewer,
provides the managed server access to media connected to a remote system
on the network. Figure 12-1 shows the overall architecture of Virtual Media.
Figure 12-1.

Overall Architecture of Virtual Media

Managed Server

Management Station

Modular Server
Remote CD/DVD/USB

Network
Remote Floppy

Configuring and Using Virtual Media

205

Using Virtual Media, administrators can remotely boot their managed
servers, install applications, update drivers, or even install new operating
systems remotely from the virtual CD/DVD and diskette drives.
NOTE: Virtual media requires a minimum available network bandwidth of 128 Kbps.
Virtual media defines two devices for the managed server’s operating system
and BIOS: a floppy disk device and an optical disk device.
The management station provides the physical media or image file across the
network. When Virtual Media is connected, all virtual CD/floppy drive
access requests from the managed server are directed to the management
station across the network. Connecting Virtual Media appears the same as
inserting media into physical devices. When virtual media is not connected,
virtual devices on the managed server appear as two drives without media
installed in the drives.
Table 12-1 lists the supported drive connections for virtual floppy and virtual
optical drives.
NOTE: Changing Virtual Media while connected could stop the system
boot sequence.
Table 12-1. Supported Drive Connections
Supported Virtual Floppy Drive
Connections

Supported Virtual Optical Drive
Connections

Legacy 1.44 floppy drive with a 1.44
floppy diskette

CD-ROM, DVD, CDRW, combination
drive with CD-ROM media

USB floppy drive with a 1.44 floppy
diskette

CD-ROM/DVD image file in the ISO9660
format

1.44 floppy image

USB CD-ROM drive with CD-ROM media

USB removable disk (minimum size
128 MB)

Windows-Based Management Station
To run the Virtual Media feature on a management station running the
Windows operating system, install a supported version of Internet Explorer
with the ActiveX Control plug-in (see "Supported Web Browsers"). Set the
browser security to Medium or a lower setting to enable Internet Explorer to
download and install signed ActiveX controls.
206

Configuring and Using Virtual Media

Depending on your version of Internet Explorer, a custom security setting for
ActiveX may be required:
1 Start Internet Explorer.
2 Click Tools→ Internet Options, and then click the Security tab.
3 Under Select a Web content zone to specify its security settings, click to
select the desired zone.
4 Under Security level for this zone, click Custom Level.
The Security Settings window appears.
5 Under ActiveX controls and plugins, ensure that the following settings are
set to Enable:
•

Allow Scriptlets

•

Automatic prompting for ActiveX controls

•

Download signed ActiveX controls

•

Download unsigned ActiveX controls

6 Click OK to save any changes and close the Security Settings window.
7 Click OK to close the Internet Options window.
8 Restart Internet Explorer.
You must have administrator rights to install ActiveX. Before installing the
ActiveX control, Internet Explorer may display a security warning.
To complete the ActiveX control installation procedure, accept the ActiveX
control when Internet Explorer prompts you with a security warning.

Linux-Based Management Station
To run the virtual media feature on a management station running the Linux
operating system, install a supported version of Firefox. See "Supported Web
Browsers" for more information.
A Java Runtime Environment (JRE) is required is required to run the console
redirection plugin. You can download a JRE from java.sun.com. JRE
version 1.6 or above is recommended.

Configuring and Using Virtual Media

207

Configuring Virtual Media
1 Log in to the iDRAC6 Web interface.
2 Click the Console/Media tab.
3 Click Configuration, and then click Virtual Media.
The Console Redirection Configuration screen appears.
4 Click Virtual Media.
5 In the Virtual Media section, select values for the settings. See Table 12-2
for information on Virtual Media configuration values.
6 Click Apply to save your settings.
An alert dialog appears with the following message: You are about
to change device configuration. All existing
redirection sessions will be closed. Do you want
to continue?
7 Click OK to continue.
An alert dialog appears with the following message: Virtual Media
Configuration successfully set.
Table 12-2. Virtual Media Configuration Values
Attribute

Value

Attach Virtual Media

Attach — Immediately attaches Virtual Media to the
server.
Detach — Immediately detaches Virtual Media from
the server.
Auto-Attach — Attaches Virtual Media to the server
only when a virtual media session is started.

Maximum Sessions

Displays the maximum number of Virtual Media
sessions allowed. This value is always 1.

NOTE: Only one virtual media user session is allowed;
however, multiple devices can be attached in a single
session. See "Running Virtual Media."
Active Sessions

208

Displays the current number of Virtual Media sessions.

Configuring and Using Virtual Media

Table 12-2.

Virtual Media Configuration Values (continued)

Attribute

Value

Virtual Media Encryption
Enabled

Enables (checked) or disables (not checked)
encryption on Virtual Media connections.

Virtual Media Port Number

The network port number used for connecting to the
Virtual Media service without encryption.
Two consecutive ports starting from the port number
specified are used to connect to the Virtual Media
service. The port number following the specified port
must not be configured for any other iDRAC6 service.
The default is 3668.

Virtual Media SSL Port
Number

The network port number used for encrypted
connections to the Virtual Media service.
Two consecutive ports starting from the port number
specified are used to connect to the Virtual Media
service. The port number following the specified port
must not be configured for any other iDRAC6 service.
The default is 3670.

Floppy Emulation

Indicates whether the Virtual Media appears as a
floppy drive or as a USB key to the server. If Floppy
Emulation is checked, the Virtual Media device
appears as a floppy device on the server. If it is
unchecked, it appears as a USB Key drive.

Enable Boot Once

Enables (checked) or disables (not checked) the
boot-once option, which automatically terminates the
Virtual Media session after the server has booted once.
This option is useful for automated deployments.

Running Virtual Media
CAUTION: Do not issue a racreset command when running a Virtual Media
session. Otherwise, undesirable results may occur, including data loss.
NOTE: The Console Viewer window application must remain active while you
access the virtual media.
1 Open a supported Web browser on your management station.
2 Log in to the iDRAC6 Web interface.

Configuring and Using Virtual Media

209

3 Click the Console/Media tab.
The Console Redirection and Virtual Media screen appears.
To change the values of any of the displayed attributes, see "Configuring
Virtual Media."
NOTE: The Floppy Image File under Floppy Drive (if applicable) may appear,
as this device can be virtualized as a virtual floppy. You can select one optical
drive and one floppy at the same time, or a single drive.

NOTE: The virtual device drive letters on the managed server do not coincide
with the physical drive letters on the management station.

NOTE: Virtual Media may not function properly on Windows operating system
clients that are configured with Internet Explorer Enhanced Security.
To resolve this issue, see your Microsoft operating system documentation or
contact your administrator.

4 Click Launch Viewer.
NOTE: On Linux, the file jviewer.jnlp is downloaded to your desktop and a
dialog box will ask what to do with the file. Choose the option to Open with
program and then select the javaws application, which is located in the bin
subdirectory of your JRE installation directory.

The iDRACView application launches in a separate window.
5 Select Media → Virtual Media Wizard…
The Media Redirection Wizard appears.
6 View the Status window at the bottom of the Wizard screen. If media is
connected, you must disconnect it before connecting a different media
source. To disconnect media, click the Disconnect button next to the
media in the Status window.
7 Select the radio button next to the media types you want to connect.
You can select both the Floppy Image radio button and one of the radio
buttons in the CD/DVD Drive section.
To connect a floppy image or ISO image, enter the path to the image
location on your local computer, or click the Browse button to navigate to
the image location.

210

Configuring and Using Virtual Media

8 Click the Connect button next to each selected media type.
The media is connected and the Status window is updated.
9 Click Close.
Disconnecting Virtual Media

1 Select Media → Virtual Media Wizard…
The Media Redirection Wizard appears.
2 Click Disconnect next to the media you wish to disconnect.
The media is disconnected and the Status window is updated.
3 Click Close.

Booting From Virtual Media
The system BIOS enables you to boot from virtual optical drives or virtual
floppy drives. During POST, enter the BIOS setup window and verify that the
virtual drives are enabled and listed in the correct order.
To change the BIOS setting, perform the following steps:
1 Boot the managed server.
2 Press  to enter the BIOS setup window.
3 Scroll to the boot sequence and press .
In the pop-up window, the virtual optical drives and virtual floppy drives
are listed with the standard boot devices.
4 Ensure that the virtual drive is enabled and listed as the first device with
bootable media. If required, follow the on-screen instructions to modify
the boot order.
5 Save the changes and exit.
The managed server reboots.
The managed server attempts to boot from a bootable device based on the
boot order. If the virtual device is connected and a bootable media is
present, the system boots to the virtual device. Otherwise, the system
overlooks the device—similar to a physical device without bootable media.

Configuring and Using Virtual Media

211

Installing Operating Systems Using Virtual Media
This section describes a manual, interactive method to install the operating
system on your management station that may take several hours to complete.
A scripted operating system installation procedure using Virtual Media may
take fewer than 15 minutes to complete. See "Deploying the Operating
System" for more information.
1 Verify the following:
•

The operating system installation DVD/CD is inserted in the
management station’s DVD/CD drive.

•

The local DVD/CD drive is selected.

•

You are connected to the virtual drives.

2 Follow the steps for booting from the virtual media in the "Booting From
Virtual Media" section to ensure that the BIOS is set to boot from the
DVD/CD drive from which you are installing.
3 Follow the on-screen instructions to complete the installation.

Using Virtual Media When the Server’s Operating System Is Running
Windows-Based Systems

On Windows systems, the virtual media drives are automounted if they are
attached and configured with a drive letter.
Using the virtual drives from within Windows is similar to using your physical
drives. When you connect to the media using the Virtual Media wizard,
the media is available at the system by clicking the drive and browsing
its content.
Linux-Based Systems

Depending on the configuration of the software on your system, the virtual
media drives may not be automounted. If your drives are not automounted,
manually mount the drives using the Linux mount command.

212

Configuring and Using Virtual Media

Frequently Asked Questions
Table 12-3 lists frequently asked questions and answers.
Table 12-3.

Using Virtual Media: Frequently Asked Questions

Question

Answer

Sometimes, I notice my
Virtual Media client
connection drop. Why?

When a network time-out occurs, iDRAC6
firmware drops the connection, disconnecting the
link between the server and the Virtual Drive.
If the Virtual Media configuration settings are
changed in the iDRAC6 Web interface or by local
RACADM commands, any connected media is
disconnected when the configuration change
is applied.
To reconnect to the Virtual Drive, use the Virtual
Media wizard.

Which operating systems
support iDRAC6?

See "Supported Operating Systems" for a list of
supported operating systems.

Which Web browsers support
iDRAC6?

See "Supported Web Browsers" for a list of
supported Web browsers.

Why do I sometimes lose my
client connection?

• You can sometimes lose your client connection if
the network is slow or if you change the CD in the
client system CD drive. For example, if you
change the CD in the client system’s CD drive,
the new CD might have an autostart feature.
If this is the case, the firmware can time out and
the connection can be lost if the client system
takes too long before it is ready to read the CD.
If a connection is lost, reconnect from the
GUI and continue the previous operation.
• When a network timeout occurs, iDRAC6
firmware drops the connection, disconnecting the
link between the server and the Virtual Drive.
Also, someone may have altered the Virtual Media
configuration settings in the Web interface or by
entering RADACM commands. To reconnect to
the Virtual Drive, use the Virtual Media feature.

Configuring and Using Virtual Media

213

Table 12-3. Using Virtual Media: Frequently Asked Questions (continued)
Question

Answer

An installation of the Windows
operating system seems to take
too long. Why?

If you are installing the Windows operating system
using the Dell PowerEdge Installation and Server
Management CD and a slow network connection,
the installation procedure may require an extended
amount of time to access the iDRAC6 Web
interface due to network latency. While the
installation window does not indicate the
installation progress, the installation procedure is
in progress.

I am viewing the contents of a
floppy drive or USB memory key.
If I try to establish a Virtual
Media connection using the
same drive, I receive a
connection failure message and
am asked to retry. Why?

Simultaneous access to Virtual Floppy drives is not
allowed. Close the application used to view the
drive contents before you attempt to virtualize
the drive.

How do I configure my virtual
device as a bootable device?

On the managed server, access the BIOS Setup and
navigate to the boot menu. Locate the virtual CD,
Virtual Floppy, or Virtual Flash and change the
device boot order as needed. For example, to boot
from a CD drive, configure the CD drive as the
first drive in the boot order.

214

Configuring and Using Virtual Media

Table 12-3.

Using Virtual Media: Frequently Asked Questions (continued)

Question

Answer

What types of media can I boot iDRAC6 allows you to boot from the following
from?
bootable media:
• CDROM/DVD Data media
• ISO 9660 image
• 1.44 Floppy disk or floppy image
• A USB key that is recognized by the operating
system as a removable disk (minimum size 128
MB)
• A USB key image
How can I make my USB key
bootable?

Search support.dell.com for the Dell Boot Utility, a
Windows program you can use to make your Dell
USB key bootable.
You can also boot with a Windows 98 startup disk
and copy system files from the startup disk to your
USB key. For example, from the DOS prompt,
enter the following command:

sys a: x: /s
where x: is the USB key you want to make bootable.
You can also use the Dell boot utility to create a
bootable USB key. This utility is only compatible
with Dell-branded USB keys. To download the
utility, open a Web browser, navigate to the Dell
Support website located at support.dell.com,
and search for R122672.exe.

Configuring and Using Virtual Media

215

Table 12-3. Using Virtual Media: Frequently Asked Questions (continued)
Question

Answer

I cannot locate my Virtual
Floppy device on a system
running Red Hat® Enterprise
Linux® or the SUSE® Linux
operating system. My Virtual
Media is attached and I am
connected to my remote floppy.
What should I do?

Some Linux versions do not automount the Virtual
Floppy Drive and the Virtual CD drive in a similar
manner. To mount the Virtual Floppy Drive,
locate the device node that Linux assigns to the
Virtual Floppy Drive. Perform the following
steps to correctly find and mount the Virtual
Floppy Drive:
1 Open a Linux command prompt and run the
following command:
grep "Virtual Floppy" /var/log/
messages
2 Locate the last entry to that message and note the
time.
3 At the Linux prompt, run the following
command:
grep "hh:mm:ss" /var/log/messages
where:

hh:mm:ss is the time stamp of the message
returned by grep in step 1.
4 In step 3, read the result of the grep command
and locate the device name that is given to the
Dell Virtual Floppy.
5 Ensure that you are attached and connected to
the Virtual Floppy Drive.
6 At the Linux prompt, run the following
command:
mount /dev/sdx /mnt/floppy
where:

/dev/sdx is the device name found in step 4
/mnt/floppy is the mount point.

216

Configuring and Using Virtual Media

Table 12-3.

Using Virtual Media: Frequently Asked Questions (continued)

Question

Answer

What file system types are
supported on my Virtual
Floppy Drive?

Your Virtual Floppy Drive supports FAT16 or
FAT32 file systems.

When I performed a firmware
update remotely using the
iDRAC6 Web interface, my
virtual drives at the server were
removed. Why?

Firmware updates cause iDRAC6 to reset, drop the
remote connection, and unmount the virtual
drives. The drives will reappear when the iDRAC6
reset is complete.

Configuring and Using Virtual Media

217

218

Configuring and Using Virtual Media

Using the Local RACADM Command
Line Interface
The local RACADM command line interface (CLI) provides access to
iDRAC6 management features from the managed server. RACADM provides
access to the same features as the iDRAC6 Web interface. However,
RACADM can be used in scripts to ease configuration of multiple servers and
iDRACs, where the Web interface is more useful for interactive management.
Local RACADM commands do not use network connections to access
iDRAC6 from the managed server. This means that you can use local
RACADM commands to configure the initial iDRAC6 networking.
For more information about configuring multiple iDRACs, see "Configuring
Multiple iDRACs."
This section provides the following information:
•

Using RACADM from a command prompt

•

Configuring iDRAC6 using the racadm command

•

Using the RACADM configuration file to configure multiple iDRACs

Using the RACADM Command
You run RACADM commands locally (on the managed server) from a
command prompt or shell prompt.
Log in to the managed server, start a command shell, and enter local
RACADM commands in the following format:
racadm  -g  -o  
Without options, the RACADM command displays general use information.
To display the RACADM subcommand list, enter:
racadm help
Using the Local RACADM Command Line Interface

219

The subcommand list includes all commands that are supported by iDRAC6.
To get help for a subcommand, enter:
racadm help 
The command displays the syntax and command-line options for the
subcommand.

RACADM Subcommands
Table 13-1 provides a description of each RACADM subcommand that you
can run in RACADM. For a detailed listing of RACADM subcommands
including syntax and valid entries, see "RACADM Subcommand Overview."
Table 13-1. RACADM Subcommands
Command

Description

clrasrscreen

Clears the last crash (ASR) screen.

clrraclog

Clears the iDRAC6 log. After clearing, a single entry is made
to indicate the user and time that the log was cleared.

clrsel

Clears the managed server’s System Event Log entries.

config

Configures iDRAC6.

getconfig

Displays the current iDRAC6 configuration properties.

getniccfg

Displays the current IP configuration for the controller.

getraclog

Displays the iDRAC6 log.

getractime

Displays the iDRAC6 time.

getssninfo

Displays information about active sessions.

getsvctag

Displays service tags.

getsysinfo

Displays information about iDRAC6 and the managed server,
including IP configuration, hardware model, firmware
versions, and operating system information.

gettracelog

Displays the iDRAC6 trace log. If used with -i, the
command displays the number of entries in the iDRAC6
trace log.

help

Lists iDRAC6 subcommands.

help  Lists usage statement for the specified subcommand.

220

Using the Local RACADM Command Line Interface

Table 13-1.

RACADM Subcommands (continued)

Command

Description

localconredirdisable

Performs local kVM disable from the local system.

racreset

Resets iDRAC6.

racresetcfg

Resets iDRAC6 to the default configuration.

serveraction

Performs power management operations on the
managed server.

setniccfg

Sets the IP configuration for the controller.

sslcertdownload

Downloads a CA certificate.

sslcertupload

Uploads a CA certificate or server certificate to iDRAC6.

sslcertview

Views a CA certificate or server certificate in iDRAC6.

sslcsrgen

Generates and downloads the SSL CSR.

testemail

Forces iDRAC6 to send an e-mail over the iDRAC6 NIC.

testtrap

Forces iDRAC6 to send an SNMP alert over the
iDRAC6 NIC.

vmkey

Resets the virtual media key to the default size of 256MB.

Using the RACADM Utility to Configure iDRAC6
This section describes how to use RACADM to perform various iDRAC6
configuration tasks.

Displaying Current iDRAC6 Settings
The RACADM getconfig subcommand retrieves current configuration
settings from iDRAC6. The configuration values are organized into groups
containing one or more objects, and the objects have values.
See "iDRAC6 Enterprise Property Database Group and Object Definitions"
for a complete description of the groups and objects.
To display a list of all iDRAC6 groups, enter this command:
racadm getconfig -h

To display the objects and values for a particular group, enter this command:
racadm getconfig -g 

Using the Local RACADM Command Line Interface

221

For example, to display a list of all cfgLanNetworking group object settings,
enter the following command:
racadm getconfig -g cfgLanNetworking

Managing iDRAC6 Users with RACADM
NOTE: Use caution when using the racresetcfg command, as all configuration
parameters are reset to the original defaults. Any previous changes are lost.
NOTE: If you are configuring a new iDRAC6 or if you ran the racadm racresetcfg
command, the only current user is root with the password calvin.
NOTE: Users can be enabled and disabled over time. As a result, a user may have a
different index number on each iDRAC6.

NOTE: Users and groups created for Active Directory environments must conform
to the Active Directory naming convention.

You can configure up to 15 users in the iDRAC6 property database.
(A sixteenth user is reserved for the IPMI LAN user.) Before you manually
enable an iDRAC6 user, verify if any current users exist.
To verify if a user exists, enter the following command at the command prompt:
racadm getconfig -u 
OR
enter the following command once for each index from 1 to 16:
racadm getconfig -g cfgUserAdmin -i 
NOTE: You can also enter racadm getconfig -f  and view
the generated  file, which includes all users, as well as all other iDRAC6
configuration parameters.

Several parameters and object IDs are displayed with their current values.
Two objects of interest are:
# cfgUserAdminIndex=nn
cfgUserAdminUserName=

222

Using the Local RACADM Command Line Interface

If the cfgUserAdminUserName object has no value, that index number,
which is indicated by the cfgUserAdminIndex object, is available for use. If a
name appears after the =, that index is assigned to that user name.
NOTE: Users and groups created for Active Directory environments must conform
to the Active Directory naming convention.

Adding an iDRAC6 User
To add a new user to iDRAC6, perform the following steps:
1 Set the user name.
2 Set the password.
3 Set the Login to iDRAC6 user privilege.
4 Enable the user.
Example

The following example describes how to add a new user named "John" with a
"123456" password and login privileges to iDRAC6:
racadm config -g cfgUserAdmin -o cfgUserAdminUserName
-i 2 john
racadm config -g cfgUserAdmin -o cfgUserAdminPassword
-i 2 123456
racadm config -g cfgUserAdmin -o cfgUserPrivilege -i 2
0x00000001
racadm config -g cfgUserAdmin -o cfgUserAdminEnable
-i 2 1
To verify the new user, use one of the following commands:
racadm getconfig -u john
racadm getconfig –g cfgUserAdmin –i 2

Using the Local RACADM Command Line Interface

223

Enabling an iDRAC6 User With Permissions
To grant a user a specific administrative (role-based) permissions, set the
cfgUserAdminPrivilege property to a bitmask constructed from the values
show in Table 13-2:
Table 13-2. Bit Masks for User Privileges
User Privilege

Privilege Bit Mask

Login to iDRAC6

0x0000001

Configure iDRAC6

0x0000002

Configure Users

0x0000004

Clear Logs

0x0000008

Execute Server Control Commands

0x0000010

Access Console Redirection

0x0000020

Access Virtual Media

0x0000040

Test Alerts

0x0000080

Execute Debug Commands

0x0000100

For example, to allow the user Configure iDRAC, Configure Users, Clear
Logs, and Access Console Redirection privileges, add the values 0x00000002,
0x00000004, 0x00000008, and 0x00000010 to construct the bitmap
0x0000002E. Then enter the following command to set the privilege:
racadm config -g cfgUserAdmin -o
cfgUserAdminPrivilege -i 2 0x0000002E

Removing an iDRAC6 User
When using RACADM, users must be disabled manually and on an
individual basis. Users cannot be deleted by using a configuration file.
The following example illustrates the command syntax that can be used to
delete a RAC user:
racadm config -g cfgUserAdmin -o cfgUserAdminUserName
-i  ""

224

Using the Local RACADM Command Line Interface

A null string of double quote characters ("") instructs iDRAC6 to remove the
user configuration at the specified index and reset the user configuration to
the original factory defaults.

Testing E-mail Alerting
The iDRAC6 e-mail alert feature allows users to receive e-mail alerts when a
critical event occurs on the managed server. The following example shows
how to test the e-mail alert feature to ensure that iDRAC6 can properly send
e-mail alerts across the network.
racadm testemail -i 2
NOTE: Ensure that the SMTP and E-mail Alert settings are configured before
testing the e-mail alert feature. See "Configuring E-Mail Alerts" for more
information.

Testing the iDRAC6 SNMP Trap Alert Feature
The iDRAC6 SNMP trap alerting feature allows SNMP trap listener
configurations to receive traps for system events that occur on the
managed server.
The following example shows how a user can test the SNMP trap alert feature.
racadm testtrap -i 2
NOTE: Before you test the iDRAC6 SNMP trap alerting feature, ensure that the
SNMP and trap settings are configured correctly. See the testtrap and testemail
subcommand descriptions to configure these settings.

Configuring iDRAC6 Network Properties
To generate a list of available network properties, enter the following:
racadm getconfig -g cfgLanNetworking
To use DHCP to obtain an IP address, use the following command to write
the object cfgNicUseDhcp and enable this feature:
racadm config -g cfgLanNetworking -o cfgNicUseDHCP 1
The commands provide the same configuration functionality as the iDRAC6
Configuration Utility when you are prompted to press . For
more information about configuring network properties with the iDRAC6
Configuration Utility, see "iDRAC6 LAN."

Using the Local RACADM Command Line Interface

225

The following is an example of how the command may be used to configure
desired LAN network properties.
racadm config -g cfgLanNetworking -o cfgNicEnable 1
racadm config -g cfgLanNetworking -o cfgNicIpAddress
192.168.0.120
racadm config -g cfgLanNetworking -o cfgNicNetmask
255.255.255.0
racadm config -g cfgLanNetworking -o cfgNicGateway
192.168.0.120
racadm config -g cfgLanNetworking -o cfgNicUseDHCP 0
racadm config -g cfgLanNetworking -o
cfgDNSServersFromDHCP 0
racadm config -g cfgLanNetworking -o cfgDNSServer1
192.168.0.5
racadm config -g cfgLanNetworking -o cfgDNSServer2
192.168.0.6
racadm config -g cfgLanNetworking -o
cfgDNSRegisterRac 1
racadm config -g cfgLanNetworking -o cfgDNSRacName
RAC-EK00002
racadm config -g cfgLanNetworking -o
cfgDNSDomainNameFromDHCP 0
racadm config -g cfgLanNetworking -o cfgDNSDomainName
MYDOMAIN
NOTE: If cfgNicEnable is set to 0, the iDRAC6 LAN is disabled even if DHCP is
enabled.

226

Using the Local RACADM Command Line Interface

Configuring IPMI Over LAN
1 Configure IPMI over LAN by entering the following command:
racadm config -g cfgIpmiLan -o cfgIpmiLanEnable 1
NOTE: This setting determines the IPMI commands that can be executed from the
IPMI over LAN interface. For more information, see the IPMI 2.0 specifications.
a

Update the IPMI channel privileges by entering the following
command:
racadm config -g cfgIpmiLan -o
cfgIpmiLanPrivilegeLimit 
where  is one of the following:
•

2 (User)

•

3 (Operator)

•

4 (Administrator)

For example, to set the IPMI LAN channel privilege to 2 (User), enter
the following command:
racadm config -g cfgIpmiLan -o
cfgIpmiLanPrivilegeLimit 2
b

Set the IPMI LAN channel encryption key, if required, using a
command such as the following:
NOTE: The iDRAC6 IPMI supports the RMCP+ protocol. See the IPMI 2.0
specifications for more information.

racadm config -g cfgIpmiLan -o
cfgIpmiEncryptionKey 
where  is a 20-character encryption key in a valid
hexadecimal format.

Using the Local RACADM Command Line Interface

227

2 Configure IPMI Serial over LAN (SOL) using the following command:
racadm config -g cfgIpmiSol -o cfgIpmiSolEnable 1
NOTE: The IPMI SOL minimum privilege level determines the minimum
privilege required to activate IPMI SOL. For more information, see the IPMI 2.0
specification.
a

Update the IPMI SOL minimum privilege level using the following
command:
racadm config -g cfgIpmiSol -o
cfgIpmiSolMinPrivilege 
where  is one of the following:
•

2 (User)

•

3 (Operator)

•

4 (Administrator)

For example, to configure the IPMI privileges to 2 (User), enter the
following command:
racadm config -g cfgIpmiSol -o
cfgIpmiSolMinPrivilege 2
NOTE: To redirect the serial console over LAN, ensure that the SOL baud rate
is identical to your managed server’s baud rate.
b

Update the IPMI SOL baud rate using the following command:
racadm config -g cfgIpmiSol -o
cfgIpmiSolBaudRate 
where  is 19200, 57600, or 115200 bps.
For example:
racadm config -g cfgIpmiSol -o
cfgIpmiSolBaudRate 57600

c

Enable SOL by typing the following command at the command prompt.
NOTE: SOL can be enabled or disabled for each individual user.
racadm config -g cfgUserAdmin -o
cfgUserAdminSolEnable -i  2
where  is the user’s unique ID.

228

Using the Local RACADM Command Line Interface

Configuring PEF
You can configure the action you wish iDRAC6 to take for each platform alert.
Table 13-3 lists the possible actions and the value to identify them in RACADM.
Table 13-3.

Platform Event Action

Action

Value

No action

0

Power off

1

Reboot

2

Power Cycle

3

1 Configure PEF actions using the following command:
racadm config -g cfgIpmiPef -o cfgIpmiPefAction
-i  
where  is the PEF index (Table 5-7), and  is a
value from Table 13-3.
For example, to enable PEF to reboot the system and send an IPMI alert
when a processor critical event is detected, enter the following command:
racadm config -g cfgIpmiPef -o cfgIpmiPefAction
-i 9 2

Configuring PET
1 Enable global alerts using the following command:
racadm config -g cfgIpmiLan -o
cfgIpmiLanAlertEnable 1
2 Enable PET using the following command:
racadm config -g cfgIpmiPet -o
cfgIpmiPetAlertEnable -i  <0|1>
where  is the PET destination index and 0 or 1 disable PET or
enable PET, respectively.
For example, to enable PET with index 4, enter the following command:
racadm config -g cfgIpmiPet -o
cfgIpmiPetAlertEnable -i 4 1
Using the Local RACADM Command Line Interface

229

3 Configure your PET policy using the following command:
racadm config -g cfgIpmiPet -o
cfgIpmiPetAlertDestIPAddr -i  
where  is the PET destination index and  is the
destination IP address of the system that receives the platform event alerts.
4 Configure the Community Name string.
At the command prompt, enter:
racadm config -g cfgIpmiLan -o
cfgIpmiPetCommunityName 
where  is the PET Community Name.
Configuring E-mail Alerts

1 Enable global alerts by entering the following command:
racadm config -g cfgIpmiLan -o
cfgIpmiLanAlertEnable 1
2 Enable e-mail alerts by entering the following commands:
racadm config -g cfgEmailAlert -o
cfgEmailAlertEnable -i  <0|1>
where  is the e-mail destination index and 0 disables the e-mail
alert or 1 enables the alert. The e-mail destination index can be a value
from 1 through 4.
For example, to enable e-mail with index 4, enter the following command:
racadm config -g cfgEmailAlert -o
cfgEmailAlertEnable -i 4 1
3 Configure your e-mail settings by entering the following command:
racadm config -g cfgEmailAlert -o
cfgEmailAlertAddress -i 1 
where 1 is the e-mail destination index and  is the
destination e-mail address that receives the platform event alerts.

230

Using the Local RACADM Command Line Interface

4 To configure a custom message, enter the following command:
racadm config -g cfgEmailAlert -o
cfgEmailAlertCustomMsg -i  
where  is the e-mail destination index and  is
the custom message.
5 Test the configured e-mail alert, if desired, by entering the following
command:
racadm testemail -i 
where  is the e-mail destination index to test.

Configuring IP Filtering (IP Range)
IP address filtering (or IP Range Checking) allows iDRAC6 access only
from clients or management workstations whose IP addresses are within a
user-specified range. All other login requests are denied.
IP filtering compares the IP address of an incoming login to the IP address
range that is specified in the following cfgRacTuning properties:
•

cfgRacTuneIpRangeAddr

•

cfgRacTuneIpRangeMask

The cfgRacTuneIpRangeMask property is applied to both the incoming
IP address and to the cfgRacTuneIpRangeAddr properties. If the results are
identical, the incoming login request is allowed to access iDRAC6.
Logins from IP addresses outside this range receive an error.
The login proceeds if the following expression equals zero:
cfgRacTuneIpRangeMask & ( ^
cfgRacTuneIpRangeAddr)
where & is the bitwise AND of the quantities and ^ is the bitwise exclusiveOR.
See "cfgRacTuning" for a complete list of cfgRacTuning properties.

Using the Local RACADM Command Line Interface

231

Table 13-4. IP Address Filtering (IPRange) Properties
Property

Description

cfgRacTuneIpRangeEnable

Enables the IP range checking feature.

cfgRacTuneIpRangeAddr

Determines the acceptable IP address bit pattern,
depending on the 1’s in the subnet mask.
This property is bitwise anded with
cfgRacTuneIpRangeMask to determine the upper
portion of the allowed IP address. Any IP address that
contains this bit pattern in its upper bits is allowed to
log in. Logins from IP addresses that are outside this
range fail. The default values in each property allow
an address range from 192.168.1.0 to 192.168.1.255
to log in.

cfgRacTuneIpRangeMask

Defines the significant bit positions in the IP address.
The mask should be in the form of a netmask,
where the more significant bits are all 1’s with a
single transition to all zeros in the lower-order bits.

Configuring IP Filtering
To configure IP filtering in the Web interface, follow these steps:
1 Click System→ Remote Access→ iDRAC→ Network/Security.
2 On the Network Configuration screen, click Advanced Settings.
3 Check the IP Range Enabled checkbox and enter the IP Range Address
and IP Range Subnet Mask.
4 Click Apply.

232

Using the Local RACADM Command Line Interface

Following are examples using local RACADM to set up IP filtering.
NOTE: See "Using the Local RACADM Command Line Interface" for more
information about RACADM and RACADM commands.
1 The following RACADM commands block all IP addresses except
192.168.0.57:
racadm config -g cfgRacTuning -o
cfgRacTuneIpRangeEnable 1
racadm config -g cfgRacTuning -o
cfgRacTuneIpRangeAddr 192.168.0.57
racadm config -g cfgRacTuning -o
cfgRacTuneIpRangeMask 255.255.255.255
2 To restrict logins to a small set of four adjacent IP addresses (for example,
192.168.0.212 through 192.168.0.215), select all but the lowest two bits in
the mask, as shown below:
racadm config -g cfgRacTuning -o
cfgRacTuneIpRangeEnable 1
racadm config -g cfgRacTuning -o
cfgRacTuneIpRangeAddr 192.168.0.212
racadm config -g cfgRacTuning -o
cfgRacTuneIpRangeMask 255.255.255.252
The last byte of the range mask is set to 252, the decimal equivalent of
11111100b.
IP Filtering Guidelines

Use the following guidelines when enabling IP filtering:
•

Ensure that cfgRacTuneIpRangeMask is configured in the form of a
netmask, where all most significant bits are 1’s (which defines the subnet
in the mask) with a transition to all 0’s in the low-order bits.

•

Use the desired range’s base address as the value of
cfgRacTuneIpRangeAddr. The 32-bit binary value of this address should
have zeros in all the low-order bits where there are zeros in the mask.

Using the Local RACADM Command Line Interface

233

Configuring IP Blocking
IP blocking dynamically determines when excessive login failures occur from
a particular IP address and blocks (or prevents) the address from logging in to
iDRAC6 for a preselected time span.
The IP blocking features include:
•

The number of allowed login failures (cfgRacTuneIpBlkFailcount)

•

The time frame in seconds during which these failures must occur
(cfgRacTuneIpBlkFailWindow)

•

The amount of time in seconds that the blocked IP address is prevented
from establishing a session after the allowed number of failures is exceeded
(cfgRacTuneIpBlkPenaltyTime)

As login failures accumulate from a specific IP address, they are registered by
an internal counter. When the user logs in successfully, the failure history is
cleared and the internal counter is reset.
NOTE: When login attempts are refused from the client IP address, some SSH clients
may display the following message: ssh exchange identification:
Connection closed by remote host.

See "iDRAC6 Enterprise Property Database Group and Object Definitions"
for a complete list of cfgRacTune properties.
"Log In Retry Restriction (IP Blocking) Properties" lists the user-defined
parameters.
Table 13-5. Log In Retry Restriction (IP Blocking) Properties
Property

Definition

cfgRacTuneIpBlkEnable

Enables the IP blocking feature.
When consecutive failures
(cfgRacTuneIpBlkFailCount) from a single
IP address are encountered within a specific amount
of time (cfgRacTuneIpBlkFailWindow), all further
attempts to establish a session from that address are
rejected for a certain time span
(cfgRacTuneIpBlkPenaltyTime).

cfgRacTuneIpBlkFailCount

234

Sets the number of login failures from an IP address
before the login attempts are rejected.

Using the Local RACADM Command Line Interface

Table 13-5.

Log In Retry Restriction (IP Blocking) Properties (continued)

Property

Definition

cfgRacTuneIpBlkFailWindow

The time frame in seconds during which the failure
attempts are counted. When the failures exceed
this limit, they are dropped from the counter.

cfgRacTuneIpBlkPenaltyTime Defines the time span in seconds that login
attempts from an IP address with excessive failures
are rejected.

Enabling IP Blocking

The following example prevents a client IP address from establishing a session
for five minutes if that client has failed five login attempts in a one-minute
period of time.
racadm config -g cfgRacTuning -o
cfgRacTuneIpRangeEnable 1
racadm config -g cfgRacTuning -o
cfgRacTuneIpBlkFailCount 5
racadm config -g cfgRacTuning -o
cfgRacTuneIpBlkFailWindow 60
racadm config -g cfgRacTuning -o
cfgRacTuneIpBlkPenaltyTime 300
The following example prevents more than three failed attempts within one
minute, and prevents additional login attempts for an hour.
racadm config -g cfgRacTuning -o
cfgRacTuneIpBlkEnable 1
racadm config -g cfgRacTuning -o
cfgRacTuneIpBlkFailCount 3
racadm config -g cfgRacTuning -o
cfgRacTuneIpBlkFailWindow 60
racadm config -g cfgRacTuning -o
cfgRacTuneIpBlkPenaltyTime 360

Using the Local RACADM Command Line Interface

235

Configuring iDRAC6 Telnet and SSH Services Using Local RACADM
The telnet/SSH console can be configured locally (on the managed server)
using RACADM commands.
NOTE: You must have Configure iDRAC6 permission to execute the commands in
this section.
NOTE: When you reconfigure telnet or SSH settings in iDRAC6, any current
sessions are terminated without warning.
To enable telnet and SSH from the local RACADM, log in to the managed
server and enter the following commands at a command prompt:
racadm config -g cfgSerial -o cfgSerialTelnetEnable 1
racadm config -g cfgSerial -o cfgSerialSshEnable 1
To disable the telnet or SSH service, change the value from 1 to 0:
racadm config -g cfgSerial -o cfgSerialTelnetEnable 0
racadm config -g cfgSerial -o cfgSerialSshEnable 0
Enter the following command to change the telnet port number on iDRAC6:
racadm config -g cfgRacTuning -o cfgRacTuneTelnetPort

For example, to change the telnet port from the default 22 to 8022, enter this
command:
racadm config -g cfgRacTuning -o cfgRacTuneTelnetPort
8022
For a complete list of available RACADM CLI commands, see "Using the
Local RACADM Command Line Interface."

Using an iDRAC6 Configuration File
An iDRAC6 configuration file is a text file that contains a representation of
the values in the iDRAC6 database. You can use the RACADM getconfig
subcommand to generate a configuration file containing the current values
from iDRAC6. You can then edit the file and use the RACADM config -f
subcommand to load the file back into iDRAC6, or to copy the configuration
to other iDRACs.

236

Using the Local RACADM Command Line Interface

Creating an iDRAC6 Configuration File
The configuration file is a plain text file. You can use any valid file name;
however, the .cfg file extension is the recommended convention.
The configuration file can be:
•

Created with a text editor

•

Obtained from iDRAC6 with the RACADM getconfig subcommand

•

Obtained from iDRAC6 with the RACADM getconfig subcommand and
then edited

To obtain a configuration file, with the RACADM getconfig command,
enter the following command at a command prompt on the managed server:
racadm getconfig -f myconfig.cfg
This command creates the file myconfig.cfg in the current directory.

Configuration File Syntax
NOTE: Edit the configuration file with a plain text editor, such as Notepad on
Windows or vi on Linux. The racadm utility parses ASCII text only. Any formatting
confuses the parser and may corrupt the iDRAC6 database.
This section describes the format of the configuration file.
•

Lines that start with # are comments.
A comment must start in the first column of the line. A # character in any
other column is treated as a normal # character.
Example:
#

# This is a comment
[cfgUserAdmin]
cfgUserAdminPrivilege=4
•

Group entries must be surrounded by [ and ] characters.
The starting [ character denoting a group name must start in column one.
This group name must be specified before any of the objects in that group.
Objects that do not include an associated group name generate an error.

Using the Local RACADM Command Line Interface

237

The configuration data is organized into groups as defined in "iDRAC6
Enterprise Property Database Group and Object Definitions."
The following example displays a group name, object, and the object’s
property value.
Example:
[cfgLanNetworking] (group name)
cfgNicIpAddress=143.154.133.121 (object name)
•

Parameters are specified as object=value pairs with no white space between
the object, =, and value.
White space that is included after the value is ignored. White space inside
a value string remains unmodified. Any character to the right of the = is
taken as is (for example, a second =, or a #, [, ], and so forth).

•

The parser ignores an index object entry.
You cannot specify which index is used. If the index already exists, it is
either used or the new entry is created in the first available index for
that group.
The racadm getconfig -f  command places
a comment in front of index objects, allowing you to see the
included comments.
NOTE: You can create an indexed group manually using the following command:
racadm config -g  -o  -i  .

•

The line for an indexed group cannot be deleted from a configuration file.
You must remove an indexed object manually using the following
command:
racadm config -g  -o  -i
 ""
NOTE: A NULL string (identified by two "" characters) directs iDRAC6 to delete the
index for the specified group.

To view the contents of an indexed group, use the following command:
racadm getconfig -g  -i 

238

Using the Local RACADM Command Line Interface

•

For indexed groups the object anchor must be the first object after the [ ]
pair. The following are examples of the current indexed groups:
[cfgUserAdmin]
cfgUserAdminUserName=

•

If the parser encounters an indexed group, it is the value of the anchored
object that differentiates the various indexes.
The parser reads in all of the indexes from iDRAC6 for that group.
Any objects within that group are simple modifications when iDRAC6 is
configured. If a modified object represents a new index, the index is
created on iDRAC6 during configuration.

•

You cannot specify a desired index in a configuration file.
Indexes may be created and deleted, so over time the group may become
fragmented with used and unused indexes. If an index is present, it is
modified. If an index is not present, the first available index is used.
This method allows flexibility when adding indexed entries where you do
not need to make exact index matches between all the RACs being
managed. New users are added to the first available index. A configuration
file that parses and runs correctly on one iDRAC6 may not run correctly on
another if all indexes are full and you must add a new user.

Modifying the iDRAC6 IP Address in a Configuration File
When you modify the iDRAC6 IP address in the configuration file, remove all
unnecessary = entries. Only the actual variable group’s
label with "[" and "]" remains, including the two =
entries pertaining to the IP address change.
For example:
#
#

Object Group "cfgLanNetworking"

#
[cfgLanNetworking]
cfgNicIpAddress=10.35.10.110
cfgNicGateway=10.35.10.1

Using the Local RACADM Command Line Interface

239

This file will be updated as follows:
#
#

Object Group "cfgLanNetworking"

#
[cfgLanNetworking]
cfgNicIpAddress=10.35.9.143
# comment, the rest of this line is ignored
cfgNicGateway=10.35.9.1

Loading the Configuration File Into iDRAC6
The command racadm config -f  parses the
configuration file to verify that valid group and object names are present and
that syntax rules are followed. If the file is error-free the command then
updates the iDRAC6 database with the contents of the file.
NOTE: To verify the syntax only and not update the iDRAC6 database, add the -c
option to the config subcommand.
Errors in the configuration file are flagged with the line number and a
message that explains the problem. You must correct all errors before the
configuration file can update iDRAC6.
NOTE: Use the racresetcfg subcommand to reset the database and the iDRAC6 NIC
settings to the original default settings and remove all users and user
configurations. While the root user is available, other users’ settings are also reset
to the default settings.

Before you execute the racadm config -f  command,
you can run the racresetcfg subcommand to reset iDRAC6 to its default
settings. Ensure that the configuration file you will load includes all desired
objects, users, indexes, and other parameters.
To update iDRAC6 with the configuration file, execute the following
command at the managed server’s command prompt:
racadm config -f 
After the command has completed, you can execute the RACADM getconfig
subcommand to confirm that the update succeeded.

240

Using the Local RACADM Command Line Interface

Configuring Multiple iDRACs
Using a configuration file, you can configure other iDRACs with identical
properties. Follow these steps to configure multiple iDRACs:
1 Create the configuration file from the iDRAC6 settings you want to
replicate to the others. At a command prompt on the managed server,
enter the following command:
racadm getconfig -f 
where  is the name of a file to save the iDRAC6 properties,
such a myconfig.cfg.
See "Creating an iDRAC6 Configuration File" for more information.
NOTE: Some configuration files contain unique iDRAC6 information (such as the
static IP address) that must be modified before you export the file to other iDRACs.

2 Edit the configuration file you created in the previous step and remove or
comment-out any settings you do not want to replicate.
3 Copy the edited configuration file to a network drive where it is accessible
to each managed server whose iDRAC6 you want to configure.
4 For each iDRAC6 you want to configure:
a

Log in to the managed server and start a command prompt.

b

If you want to reconfigure iDRAC6 from the default settings, enter
the following command:
racadm racreset

c

Load the configuration file into iDRAC6 with the following
command:
racadm config -f 
where  is the name of the configuration file you created.
Include the full path if the file is not in the working directory.

d

Reset the iDRAC6 that was configured by entering the following
command:
racadm reset

Using the Local RACADM Command Line Interface

241

242

Using the Local RACADM Command Line Interface

Using iDRAC6 Enterprise
SM-CLP Command Line Interface
This section provides information about the Server Management Workgroup
(SMWG) Server Management-Command Line Protocol (SM-CLP) that is
incorporated in iDRAC6.
NOTE: This section assumes that you are familiar with the Systems Management
Architecture for Server Hardware (SMASH) Initiative and the SMWG SM-CLP
specifications. For more information on these specifications, see the Distributed
Management Task Force (DMTF) website at www.dmtf.org.
The iDRAC6 SM-CLP is a protocol driven by the DMTF and SMWG to
provide standards for systems management CLI implementations. Many
efforts are driven by a defined SMASH architecture that is targeted as a
foundation for more standardized systems management set of components.
The SMWG SM-CLP is a subcomponent of the overall SMASH efforts
driven by DMTF.
SM-CLP provides a subset of the functionality provided by the local
RACADM command line interface, but with a different access path. SM-CLP
executes within iDRAC6, while RACADM executes on the managed server.
Also, RACADM is a Dell proprietary interface, where SM-CLP is an industry
standard interface. See "RACADM and SM-CLP Equivalencies" for a
mapping of the RACADM and SM-CLP commands.

System Management With SM-CLP
The iDRAC6 SM-CLP enables you to manage the following system features
from a command line or script:
•

Server Power Management — Turn on, shutdown, or reboot the system

•

System Event Log (SEL) Management — Display or clear the SEL records

•

iDRAC6 user account management
Using iDRAC6 Enterprise SM-CLP Command Line Interface

243

•

Active Directory configuration

•

iDRAC6 LAN configuration

•

SSL Certificate Signature Request (CSR) generation

•

Virtual media configuration

•

Serial over LAN (SOL) redirection over Telnet or SSH

iDRAC6 SM-CLP Support
SM-CLP is hosted from iDRAC6 firmware, and supports telnet and SSH
connections. The iDRAC6 SM-CLP interface is based on the SM-CLP
Specification Version 1.0 provided by the DMTF organization.
The following sections provide an overview of the SM-CLP feature that is
hosted from iDRAC6.

SM-CLP Features
The SM-CLP specification provides a common set of standard SM-CLP verbs
that can be used for simple systems management through the CLI.
SM-CLP promotes the concept of verbs and targets to provide system
configuration capabilities through the CLI. The verb indicates the operation
to perform and the target determines the entity (or object) that runs the
operation.
The following is the syntax of the SM-CLP command line:
 [] [] []

244

Using iDRAC6 Enterprise SM-CLP Command Line Interface

Table 14-1 provides a list of the verbs the iDRAC6 CLI supports, the syntax of
each command, and a list of the options the verb supports.
Table 14-1.

Supported SM-CLP CLI Verbs

Verb

Description

cd

Navigates through the managed system address –default, –examine, –
help, –output, –version
space using the shell.

Options

Syntax:
cd [options] [target]
delete

Deletes an object instance.
Syntax:

–examine, –help, –
output, –version

delete [options] target
dump

Moves a binary image from the MAP to a URI. –destination, –examine,
dump -destination  [options] –help, –output, –
version
[target]

exit

Exits from the SM-CLP shell session.
Syntax:

–help, –output, –
version

exit [options]
help

Displays help for SM-CLP commands.
help

load

-examine, -help,
-output, -version

Moves a binary image to the MAP from a URI. –examine, –help, –
output, –source, –
version
load -source  [options]
[target]
Syntax:

reset

Resets the target.
Syntax:

–examine, –help, –
output, –version

reset [options] [target]
set

Sets the properties of a target
Syntax:

–examine, –help, –
output, –version

set [options] [target]
=

Using iDRAC6 Enterprise SM-CLP Command Line Interface

245

Table 14-1. Supported SM-CLP CLI Verbs (continued)
Verb

Description

Options

show

Displays the target properties, verbs, and
subtargets.

-all, -default, –display, –
examine, –help, –level,
–output, –version

Syntax:
show [options] [target]
=
start

Starts a target.
Syntax:

–examine, –force, –
help, –output, –version

start [options] [target]
stop

Shuts down a target.
Syntax:
stop [options] [target]

version

Displays the version attributes of a target.
Syntax:

–examine, –force, –
help, –output, –version,
–wait
–examine, –help, –
output, –version

version [options]

Table 14-2 describes the SM-CLP options. Some options have abbreviated
forms, as shown in the table.
Table 14-2. Supported SM-CLP Options
SM-CLP Option

Description

–all, –a

Instructs the verb to perform all possible functions.

-destination

Specifies the location to store an image in the dump
command.
Syntax:
-destination 

-display, -d

Filters the command output.
Syntax:
-display [,
]*

246

Using iDRAC6 Enterprise SM-CLP Command Line Interface

Table 14-2.

Supported SM-CLP Options (continued)

SM-CLP Option

Description

-examine, -x

Instructs the command processor to validate the command
syntax without executing the command.

–help, –h

Displays help for the verb.

–level, -l

Instructs the verb to operate on targets at additional levels
beneath the specified target.
Syntax:
-level 

–output, –o

Specifies the format for the output.
Syntax:
-output 

-source

Specifies the location of an image in a load command.
Syntax:
-source 

–version, –v

Displays the SMASH-CLP version number.

Navigating the MAP Address Space
NOTE: The slash (/) and backslash (\) are interchangeable in SM-CLP address
paths. However, a backslash at the end of a command line continues the command
on the next line and is ignored when the command is parsed.
Objects that can be managed with SM-CLP are represented by targets
arranged in a hierarchical space called the Manageability Access Point (MAP)
address space. An address path specifies the path from the root of the address
space to an object in the address space.
The root target is represented by a slash (/) or a backslash (\). It is the default
starting point when you log in to iDRAC6. Navigate down from the root using
the cd verb. For example to navigate to the third record in the System Event
Log (SEL), enter the following command:
->cd /system1/sp1/logs1/record3

Using iDRAC6 Enterprise SM-CLP Command Line Interface

247

Enter the cd verb with no target to find your current location in the address
space. The .. and . abbreviations work as they do in Windows and Linux:
.. refers to the parent level and . refers to the current level.

Targets
Table 14-3 provides a list of targets available through the SM-CLP.
Table 14-3. SM-CLP Targets
Target

Definition

/system1/

The managed system target.

/system1/sp1

The service processor.

/system1/sol1

Serial over LAN target.

/system1/sp1/account1 through /
system1/sp1/account16

The sixteen local iDRAC6 user accounts.
account1 is the root account.

/system1/sp1/enetport1

The iDRAC6 NIC MAC address.

/system1/sp1/enetport1/lanendpt1/
ipendpt1

The iDRAC6 IP, gateway, and netmask settings.

/system1/sp1/enetport1/lanendpt1/
ipendpt1/dnsendpt1

The iDRAC6 DNS server settings.

/system1/sp1/group1 through /
system1/sp1/group5

The Active Directory standard schema groups.

/system1/sp1/logs1

The log collections target.

/system1/sp1/logs1/record1

An individual SEL record instance on the
managed system.

/system1/sp1/logs1/records

The SEL target on the managed system.

/system1/sp1/oemdell_racsecurity1

Storage for parameters used to generate a
Certificate Signing Request.

/system1/sp1/oemdell_ssl1

SSL certificate request state.

/system1/sp1/oemdell_vmservice1

The virtual media configuration and state.

248

Using iDRAC6 Enterprise SM-CLP Command Line Interface

Using the Show Verb
To learn more about a target use the show verb. This verb displays the
target’s properties, sub-targets, and a list of the SM-CLP verbs that are
allowed at that location.

Using the -display Option
The show –display option allows you to limit the output of the command to
one or more of properties, targets, and verbs. For example, to display just the
properties and targets at the current location, use the following command:
show -d properties,targets /system1/sp1/account1
To list only certain properties, qualify them, as in the following command:
show -d properties=(userid,username) /system1/sp1/
account1
If you only want to show one property, you can omit the parentheses.

Using the -level Option
The show -level option executes show over additional levels beneath the
specified target. For example, if you want to see the username and userid
properties of the account1 through account16 targets beneath /system1/sp1,
you could enter the following command:
show -l 1 -d properties=(userid,username) /system1/
sp1/account*
To see all targets and properties in the address space, use the -l all option,
as in the following command:
show -l all -d properties /

Using the -output Option
The -output option specifies one of four formats for the output of SM-CLP
verbs: text, clpcsv, keyword, and clpxml.
The default format is text, and is the most readable output. The clpcsv
format is a comma-separated values format suitable for loading into a
spreadsheet program. The keyword format outputs information as a list of
keyword=value pairs one per line. The clpxml format is an XML document

Using iDRAC6 Enterprise SM-CLP Command Line Interface

249

containing a response XML element. The DMTF has specified the clpcsv and
clpxml formats and their specifications can be found on the DMTF website
at www.dmtf.org.
The following example shows how to output the contents of the SEL in XML:
show -l all -output format=clpxml /system1/sp1/logs1

iDRAC6 SM-CLP Examples
The following subsections provide examples for using the SM-CLP to
perform the following operations:
•

Server power management

•

SEL management

•

MAP target navigation

•

Display system properties

•

Setting the iDRAC6 IP address, subnet mask, and gateway address

For information on the use of the iDRAC6 SM-CLP interface, see "iDRAC6
SM-CLP Property Database."

Server Power Management
Table 14-4 provides examples of using SM-CLP to perform power
management operations on a managed server.
Table 14-4. Server Power Management Operations
Operation

Syntax

Logging in to
iDRAC6 using the
SSH interface

>ssh 192.168.0.120
>login: root
>password:

Power down the
server

->stop /system1
system1 has been stopped successfully

Power up the server ->start /system1
from a powered-off system1 has been started successfully
state
Reboot the server

250

->reset /system1
system1 has been reset successfully

Using iDRAC6 Enterprise SM-CLP Command Line Interface

SEL Management
Table 14-5 provides examples of using the SM-CLP to perform SEL-related
operations on the managed system.
Table 14-5.

SEL Management Operations

Operation

Syntax

Viewing the
SEL

->show /system1/sp1/logs1
Targets:
record1
record2
record3
record4
record5
Properties:
Description=IPMI SEL
MaxNumberOfRecords=512
CurrentNumberOfRecords=5
Verbs:
cd
delete
exit
help
show
version

Using iDRAC6 Enterprise SM-CLP Command Line Interface

251

Table 14-5. SEL Management Operations (continued)
Operation

Syntax

Viewing the
SEL record

->show /system1/sp1/logs1/record4
ufip=/system1/sp1/logs1/log1/record4
Properties:
Caption=Not defined
Description=Backplane Drive 0: drive slot
sensor for Backplane, drive presence was
asserted
ElementName=Not Supported
LogCreationClassName=CIM_RecordLog
LogName=IPMI SEL
CreationClassName=CIM_LogRecord
RecordID=4
MessageTimeStamp=16:37:10,January 13,2007
Verbs:
cd
exit
help
show
version

Clearing the
SEL

252

->delete /system1/sp1/logs1
All records deleted successfully

Using iDRAC6 Enterprise SM-CLP Command Line Interface

MAP Target Navigation
Table 14-6 provides examples of using the cd verb to navigate the MAP. In all
examples, the initial default target is assumed to be /.
Table 14-6.

Map Target Navigation Operations

Operation

Syntax

Navigate to the
system target and
reboot

->cd system1
->reset

NOTE: The current default target is /.
Navigate to the SEL ->cd system1
target and display the ->cd sp1
log records
->cd logs1
->show
->cd system1/sp1/logs1
->show
Display current target ->cd .
Move up one level

->cd ..

Exiting the shell

->exit

Setting the iDRAC6 IP Address, Subnet Mask, and Gateway Address
Using SM-CLP to update the iDRAC6 network properties is a two-part
process:
1 Set new values for the NIC properties at location /system1/sp1/enetport1/
lanendpt1/ipendpt1:
–

oemdell_nicenable — Set to 1 to enable iDRAC6 networking, 0 to
disable iDRAC6 networking

–

ipaddress — The IP address

–

subnetmask — The subnet mask

–

oemdell_usedhcp — Set to 1 to enable using DHCP to set the
ipaddress and subnetmask properties, 0 to set static values

2 Commit the new values by setting the committed property to 1.

Using iDRAC6 Enterprise SM-CLP Command Line Interface

253

Whenever the commit property has the value of 1, the current settings of the
properties are active. When you change any of the properties, the commit
property is reset to 0 to indicate that the values have not been committed.
NOTE: The commit property only affects the properties at the /system1/sp1/
enetport1/lanendpt1/ipendpt1 MAP location. All other SM-CLP commands take
effect immediately.
NOTE: If you use local RACADM to set the iDRAC6 network properties, your
changes take affect immediately because local RACADM does not depend upon a
network connection.
When you commit the changes, the new network settings take effect, which
causes your telnet or ssh session to be terminated. By introducing the commit
step, you can delay the termination of your session until you have completed
all of your SM-CLP commands.
Table 14-7 provides examples of setting the iDRAC6 properties using SM-CLP.
Table 14-7. Setting iDRAC6 Networking Properties with SM-CLP
Operation

Syntax

Navigate to the
->cd /system1/sp1/enetport1/lanendpt1/
iDRAC6 NIC
ipendpt1
properties location
Set the new IP
address

->set ipaddress=10.10.10.10

Set the subnet
mask

->set subnetmask=255.255.255.255

Turn on the DHCP ->set oemdell_usedhcp=1
flag
Enable the NIC

->set oemdell_nicenable=1

Commit the
changes

->set committed=1

254

Using iDRAC6 Enterprise SM-CLP Command Line Interface

Updating iDRAC6 Firmware Using SM-CLP
To update iDRAC6 firmware using SM-CLP, you must know the TFTP URI
for the Dell update package.
Follow these steps to update the firmware using SM-CLP:
1 Log in to iDRAC6 using telnet or SSH.
2 Check the current firmware version by entering the following command:
version
3 Enter the following command:
load -source tftp:/// /
system1/sp1
where  is the DNS name or IP address of your TFTP server
and  is the path to the update package on the TFTP server.
Your telnet or SSH session will be terminated. You may need to wait several
minutes for the firmware update to complete.
4 To verify that the new firmware was written, start a new telnet or SSH
session and re-enter the version command again.

Using iDRAC6 Enterprise SM-CLP Command Line Interface

255

256

Using iDRAC6 Enterprise SM-CLP Command Line Interface

Deploying Your Operating System
Using iVMCLI
The Integrated Virtual Media Command Line Interface (iVMCLI) utility is a
command-line interface that provides virtual media features from the
management station to iDRAC6 in the remote system. Using iVMCLI and
scripted methods, you can deploy your operating system on multiple remote
systems in your network.
This section provides information on integrating the iVMCLI utility into your
corporate network.

Before You Begin
Before using the iVMCLI utility, ensure that your targeted remote systems
and corporate network meet the requirements listed in the following sections.

Remote System Requirements
•

iDRAC6 is configured in each remote system.

Network Requirements
A network share must contain the following components:
•

Operating system files

•

Required drivers

•

Operating system boot image file(s)
The image file must be an operating system CD or a CD/DVD ISO image
with an industry-standard, bootable format.

Deploying Your Operating System Using iVMCLI

257

Creating a Bootable Image File
Before you deploy your image file to the remote systems, ensure that a
supported system can boot from the file. To test the image file, transfer the
image file to a test system using the iDRAC6 Web user interface and then
reboot the system.
The following sections provide specific information for creating image files
for Linux and Windows systems.

Creating an Image File for Linux Systems
Use the Data Duplicator (dd) utility to create a bootable image file for your
Linux system.
To run the utility, open a command prompt and enter the following:
dd if= of=
For example:
dd if=/dev/sdc0 of=mycd.img

Creating an Image File for Windows Systems
When choosing a data replicator utility for Windows image files, select a
utility that copies the image file and the CD/DVD boot sectors.

Preparing for Deployment
Configuring the Remote Systems
1 Create a network share that can be accessed by the management station.
2 Copy the operating system files to the network share.
3 If you have a bootable, preconfigured deployment image file to deploy the
operating system to the remote systems, skip this step.
If you do not have a bootable, preconfigured deployment image file, create
the file. Include any programs and/or scripts used for the operating system
deployment procedures.
For example, to deploy a Microsoft® Windows® operating system, the
image file may include programs that are similar to deployment methods
used by Microsoft Systems Management Server (SMS).
258

Deploying Your Operating System Using iVMCLI

When you create the image file, do the following:
•

Follow standard network-based installation procedures.

•

Mark the deployment image as "read only" to ensure that each target
system boots and executes the same deployment procedure.

4 Perform one of the following procedures:
•

Integrate IPMItool and the Virtual Media command line interface
(iVMCLI) into your existing operating system deployment
application. Use the sample ivmdeploy script as a guide to using
the utility.

•

Use the existing ivmdeploy script to deploy your operating system.

Deploying the Operating System
Use the iVMCLI utility and the ivmdeploy script included with the utility to
deploy the operating system to your remote systems.
Before you begin, review the sample ivmdeploy script included with the
iVMCLI utility. The script shows the detailed steps needed to deploy the
operating system to remote systems in your network.
The following procedure provides a high-level overview for deploying the
operating system on targeted remote systems.
1 List the iDRAC6 IP addresses of the remote systems that will be deployed
in the ip.txt text file, one IP address per line.
2 Insert a bootable operating system CD or DVD into the client media drive.
3 Run ivmdeploy at the command line.
To run the ivmdeploy script, enter the following command at the command
prompt:
ivmdeploy -r ip.txt -u  -p 
-c { | }
where:
•

 is the iDRAC6 user name—for example, root

•

 is the password for the iDRAC6 user—for example, calvin

Deploying Your Operating System Using iVMCLI

259

•

 is the path to an ISO9660 image of the operating system
installation CD or DVD

•

 is the path to the device containing the operating system
installation CD or DVD

The ivmdeploy script passes its command line options to the iVMCLI utility.
See "Command Line Options" for details about these options. The script
processes the -r option slightly differently than the iVMCLI -r option. If the
argument to the -r option is the name of an existing file, the script reads
iDRAC6 IP addresses from the specified file and runs the iVMCLI utility
once for each line. If the argument to the -r option is not a filename, then it
should be the address of a single iDRAC6. In this case, the -r works as
described for the iVMCLI utility.
The ivmdeploy script supports installation only from a CD/DVD or a CD/
DVD ISO9660 image. If you need to install from a floppy disk or a floppy disk
image, you can modify the script to use the iVMCLI -f option.

Using the Virtual Media Command Line
Interface Utility
The Virtual Media Command Line Interface (iVMCLI) utility is a scriptable
command-line interface that provides virtual media features from the
management station to iDRAC6.
The iVMCLI utility provides the following features:
NOTE: When virtualizing read-only image files, multiple sessions may share
the same image media. When virtualizing physical drives, only one session
can access a given physical drive at a time.

•

Removable media devices or image files that are consistent with the
Virtual Media plug-ins

•

Automatic termination when the iDRAC6 firmware boot once option
is enabled

•

Secure communications to iDRAC6 using Secure Sockets Layer (SSL)

Before you run the utility, ensure that you have Virtual Media user privilege
to iDRAC6.

260

Deploying Your Operating System Using iVMCLI

If your operating system supports administrator privileges or an operating
system-specific privilege or group membership, administrator privileges are
also required to run the iVMCLI command.
The client system’s administrator controls user groups and privileges,
thereby controlling the users who can run the utility.
For Windows systems, you must have Power User privileges to run the
iVMCLI utility.
For Linux systems, you can access the iVMCLI utility without administrator
privileges by using the sudo command. This command provides a centralized
means of providing non-administrator access and logs all user commands.
To add or edit users in the iVMCLI group, the administrator uses the visudo
command. Users without administrator privileges can add the sudo command
as a prefix to the iVMCLI command line (or to the iVMCLI script) to obtain
access to iDRAC6 in the remote system and run the utility.

Installing the iVMCLI Utility
The iVMCLI utility is located on the Dell Systems Management Tools and
Documentation DVD, which is included with your Dell OpenManage System
Management Software Kit. To install the utility, insert the DVD into your
system, and follow the on-screen instructions.
The Dell Systems Management Tools and Documentation DVD contains the
latest systems management software products, including diagnostics, storage
management, remote access service, and the RACADM utility. This DVD also
contains readme files, which provide the latest systems management software
product information.
The Dell Systems Management Tools and Documentation DVD also includes
ivmdeploy—a sample script that illustrates how to use the iVMCLI and
RACADM utilities to deploy software to multiple remote systems.
NOTE: The ivmdeploy script is dependent upon the other files that are present in its
directory when it is installed. If want to use the script from another directory, you
must copy all of the files with it.

Deploying Your Operating System Using iVMCLI

261

Command Line Options
The iVMCLI interface is identical on both Windows and Linux systems.
The utility uses options that are consistent with the RACADM utility
options. For example, an option to specify the iDRAC6 IP address requires
the same syntax for both RACADM and iVMCLI utilities.
The iVMCLI command format is as follows:
iVMCLI [parameter] [operating_system_shell_options]
Command-line syntax is case sensitive. See "iVMCLI Parameters" for more
information.
If the remote system accepts the commands and iDRAC6 authorizes the
connection, the command continues to run until either of the following
occurs:
•

The iVMCLI connection terminates for any reason.

•

The process is manually terminated using an operating system control.
For example, in Windows, you can use the Task Manager to terminate
the process.

iVMCLI Parameters
iDRAC6 IP Address

-r [:]
This parameter provides the iDRAC6 IP address and SSL port, which the
utility needs to establish a Virtual Media connection with the target iDRAC6.
If you enter an invalid IP address or DDNS name, an error message appears
and the command is terminated.
 is a valid, unique IP address or the iDRAC6 Dynamic
Domain Naming System (DDNS) name (if supported). If  is omitted, port 443 (the default port) is used. The optional SSL port is
not required unless you change the iDRAC6 default SSL port.
iDRAC6 User Name

-u 
This parameter provides the iDRAC6 user name that will run Virtual Media.

262

Deploying Your Operating System Using iVMCLI

The  must have the following attributes:
•

Valid user name

•

iDRAC6 Virtual Media User permission

If iDRAC6 authentication fails, an error message appears and the command is
terminated.
iDRAC6 User Password

-p 
This parameter provides the password for the specified iDRAC6 user.
If iDRAC6 authentication fails, an error message displays and the command
terminates.
Floppy/Disk Device or Image File

-f { | }
where  is a valid drive letter (for Windows systems) or a valid
device file name, including the mountable file system partition number, if
applicable (for Linux systems); and  is the filename and path of
a valid image file.
This parameter specifies the device or file to supply the virtual floppy/disk
media.
For example, an image file is specified as:
-f c:\temp\myfloppy.img (Windows system)
-f /tmp/myfloppy.img (Linux system)
If the file is not write-protected, Virtual Media may write to the image file.
Configure the operating system to write-protect a floppy image file that
should not be overwritten.
For example, a device is specified as:
-f a:\ (Windows system)
-f /dev/sdb4 # 4th partition on device /dev/sdb
(Linux system)
If the device provides a write-protection capability, use this capability to
ensure that Virtual Media will not write to the media.

Deploying Your Operating System Using iVMCLI

263

Omit this parameter from the command line if you are not virtualizing floppy
media. If an invalid value is detected, an error message displays and the
command terminates.
CD/DVD Device or Image File

-c { | }
where  is a valid CD/DVD drive letter (Windows systems) or
a valid CD/DVD device file name (Linux systems) and  is the
file name and path of a valid ISO-9660 image file.
This parameter specifies the device or file that will supply the virtual
CD/DVD-ROM media:
For example, an image file is specified as:
-c c:\temp\mydvd.img (Windows systems)
-c /tmp/mydvd.img (Linux systems)
For example, a device is specified as:
-c d:\ (Windows systems)
-c /dev/cdrom (Linux systems)
Omit this parameter from the command line if you are not virtualizing
CD/DVD media. If an invalid value is detected, an error message is listed and
the command terminates.
Specify at least one media type (floppy or CD/DVD drive) with the
command, unless only switch options are provided. Otherwise, an error
message displays and the command terminates and generates an error.
Version Display

-v
This parameter is used to display the iVMCLI utility version. If no other
non-switch options are provided, the command terminates without an error
message.

264

Deploying Your Operating System Using iVMCLI

Help Display

-h
This parameter displays a summary of the iVMCLI utility parameters. If no other
non-switch options are provided, the command terminates without error.
Manual Display

-m
This parameter displays a detailed “man page” for the iVMCLI utility,
including descriptions of all of the possible options.
Encrypted Data

-e
When this parameter is included in the command line, iVMCLI will use an
SSL-encrypted channel to transfer data between the management station and
iDRAC6 in the remote system. If this parameter is not included in the
command line, the data transfer is not encrypted.

iVMCLI Operating System Shell Options
The following operating system features can be used in the iVMCLI
command line:
•

stderr/stdout redirection — Redirects any printed utility output to a file.
For example, using the greater-than character (>) followed by a filename
overwrites the specified file with the printed output of the iVMCLI utility.
NOTE: The iVMCLI utility does not read from standard input (stdin). As a
result, stdin redirection is not required.

•

Background execution — By default, the iVMCLI utility runs in the
foreground. Use the operating system's command shell features to cause
the utility to run in the background. For example, under a Linux operating
system, the ampersand character (&) following the command causes the
program to be spawned as a new background process.

Deploying Your Operating System Using iVMCLI

265

The latter technique is useful in script programs, as it allows the script to
proceed after a new process is started for the iVMCLI command (otherwise,
the script would block until the iVMCLI program is terminated).
When multiple iVMCLI instances are started in this way, and one or more of
the command instances must be manually terminated, use the operating
system-specific facilities for listing and terminating processes.
iVMCLI Return Codes

0 = No error
1 = Unable to connect
2 = iVMCLI command line error
3 = RAC firmware connection dropped
English-only text messages are also issued to standard error output whenever
errors are encountered.

266

Deploying Your Operating System Using iVMCLI

Using the iDRAC6 Configuration
Utility
Overview
The iDRAC6 Configuration Utility is a pre-boot configuration environment
that allows you to view and set parameters for iDRAC6 and for the managed
server. Specifically, you can:
•

View the firmware revision numbers for iDRAC6 and primary backplane
firmware

•

Configure, enable, or disable the iDRAC6 local area network (LAN)

•

Enable or disable IPMI Over LAN

•

Configure LAN parameters

•

Enable, disable, or cancel System Services

•

Attach or detach the Virtual Media devices

•

Change the administrative username and password

•

Reset the iDRAC6 configuration to the factory defaults

•

View System Event Log (SEL) messages or clear messages from the log

The tasks you can perform using iDRAC6 Configuration Utility can also be
performed using other utilities provided by the iDRAC6 or Dell OpenManage
software, including the Web-based interface, the SM-CLP command line
interface, the local RACADM command line interface and, in the case
of basic network configuration, at the iDRAC6 LCD during initial
iDRAC6 configuration.

Using the iDRAC6 Configuration Utility

267

Starting the iDRAC6 Configuration Utility
You must use an iDRAC6 KVM-connected console to access the iDRAC6
Configuration Utility initially or after a resetting iDRAC6 to the
default settings.
1 At the keyboard connected to the iDRAC6 KVM console, press  to display the iDRAC6 KVM On Screen Configuration and
Reporting (OSCAR) menu. Use  and  to
highlight the slot containing your server, then press .
2 Turn on or restart the server by pressing the power button on the front of
the server.
3 When you see the message Press  for Remote
Access Setup within 5 sec....., immediately press
. The iDRAC6 Configuration Utility displays.
NOTE: If your operating system begins to load before you press ,
allow the system to finish booting, then restart your server and try again.
The first two lines of the Configuration Utility provide information about
iDRAC6 firmware and primary backplane firmware revisions. The revision
levels can be useful in determining whether a firmware upgrade is needed.
iDRAC6 firmware is the portion of the firmware concerned with external
interfaces, such as the Web-based interface, SM-CLP, and Web interfaces.
The primary backplane firmware is the portion of the firmware that interfaces
with and monitors the server hardware environment.

Using the iDRAC6 Configuration Utility
Beneath the firmware revision messages, the remainder of the iDRAC6
Configuration Utility is a menu of items that you can access by using the
up-arrow and down-arrow keys.

268

•

If a menu item leads to a submenu or an editable text field, press
 to access the item and  to leave it when you have
finished configuring it.

•

If an item has selectable values, such as Yes/No or Enabled/Disabled, press
the left-arrow or right-arrow keys or the spacebar to choose a value.

•

If an item is not editable, it appears in blue. Some items become editable
depending upon other selections you make.
Using the iDRAC6 Configuration Utility

•

The bottom line of the screen displays instructions for the current item.
You can press  to display help for the current item.

•

When you have finished using the iDRAC6 Configuration Utility,
press  to view the exit menu, where you can choose to save or
discard your changes or return to the utility.

The following sections describe the iDRAC6 Configuration Utility menu items.

iDRAC6 LAN
Use the left-arrow and right-arrow keys and the spacebar to select between
Enabled and Disabled.
The iDRAC6 LAN is disabled in the default configuration. The LAN must be
enabled to permit the use of iDRAC6 facilities, such as the Web-based
interface, telnet/SSH access to the SM-CLP command line interface, console
redirection, and virtual media.
If you choose to disable the LAN the following warning displays:
iDRAC Out-of-Band interface will be disabled if the
LAN Channel is OFF.
The message informs you that in addition to facilities that you access by
connecting to the iDRAC6 HTTP, HTTPS, telnet, or SSH ports directly,
out-of-band management network traffic, such as IPMI messages sent to
iDRAC6 from a management station, are not received when the LAN is
disabled. The local RACADM interface remains available and can be used to
reconfigure the iDRAC6 LAN.
Press any key to clear the message and continue.

IPMI Over LAN
Press the left-arrow and right-arrow keys and the spacebar to choose between
On and Off. When Off is selected, iDRAC6 will not accept IPMI messages
arriving over the LAN interface.
If you choose Off, the following warning displays:
iDRAC Out-of-Band interface will be disabled if IPMI
Over LAN is OFF.
Press any key to clear the message and continue. For an explanation of the
message, see "iDRAC6 LAN."
Using the iDRAC6 Configuration Utility

269

LAN Parameters
Press  to display the LAN Parameters submenu. When you have
finished configuring the LAN parameters, press  to return to the
previous menu.
Table 16-1. LAN Parameters
Item

Description

RMCP+
Encryption Key

Press  to edit the value,  when finished.
The RMCP+ Encryption key is a 40-character hexadecimal
string (characters 0-9, a-f, and A-F). RMCP+ is an IPMI
extension that adds authentication and encryption to IPMI.
The default value is a string of 40 zeroes.

IP Address Source

Select between DHCP and Static. When DHCP is selected,
the Ethernet IP Address, Subnet Mask, and Default Gateway
fields are obtained from a DHCP server. If no DHCP server is
found on the network, the fields are set to zeros.
When Static is selected, the Ethernet IP Address, Subnet
Mask, and Default Gateway items become editable.

Ethernet IP Address If the IP Address Source is set to DHCP, this field displays the
IP address obtained from DHCP.
If the IP Address Source is set to Static, enter the IP address
you wish to assign to the iDRAC.
The default is 192.168.0.120 plus the number of the slot
containing the server.
MAC Address

This is the non-editable MAC address of the iDRAC6 network
interface.

Subnet Mask

If the IP Address Source is set to DHCP, this field displays the
subnet mask address obtained from DHCP.
If the IP Address Source is set to Static, enter the subnet mask
for the iDRAC.
The default is 255.255.255.0.

270

Using the iDRAC6 Configuration Utility

Table 16-1.

LAN Parameters (continued)

Item

Description

Default Gateway

If the IP Address Source is set to DHCP, this field displays the
IP address of the default gateway obtained from DHCP.
If the IP Address Source is set to Static, enter the IP address of
the default gateway.
The default is 192.168.0.1.

LAN Alert Enabled Select On to enable the Platform Event Trap (PET) LAN alert.
Alert Policy Entry 1 Select Enable or Disable to activate the first alert destination.
Alert Destination 1 Enter the IP address where PET LAN alerts will be forwarded.
Host Name String

Press  to edit. Enter the name of the host for
PET alerts.

DNS Servers from
DHCP

Select On to retrieve DNS server addresses from a DHCP
service on the network. Select Off to specify the DNS server
addresses below.

DNS Server 1

If DNS Servers from DHCP is Off, enter the IP address of
the first DNS server.

DNS Server 2

If DNS Servers from DHCP is Off, enter the IP address of
the second DNS server.

Register iDRAC
Name

Select On to register the iDRAC6 name in the DNS service.
Select Off if you do not want users to be able to find the
iDRAC6 name in DNS.

iDRAC Name

If Register iDRAC Name is set to On, press  to edit
the Current DNS iDRAC Name text field. Press 
when you have finished editing the iDRAC6 name. Press
 to return to the previous menu. The iDRAC6 name
must be a valid DNS host name.

Domain Name from Select On if you want to obtain the domain name from a
DHCP
DHCP service on the network. Select Off if you want to specify
the domain name.
Domain Name

If Domain Name from DHCP is Off, press  to edit
the Current Domain Name text field. Press  when
you have finished editing. Press  to return to the
previous menu. The domain name must be a valid DNS
domain, for example mycompany.com.

Using the iDRAC6 Configuration Utility

271

Virtual Media Configuration
Virtual Media

Use the left-arrow and right-arrow keys to select Attached or Detached.
•

If you select Attached, the virtual media devices are attached to the USB
bus, making them available for use during Console Redirection sessions.

•

If you select Detached, users cannot access virtual media devices during
Console Redirection sessions.
NOTE: To use a USB Flash Drive with the Virtual Media feature, you must set USB
Flash Drive Emulation Type to Hard disk in the BIOS Setup Utility. Access the BIOS
Setup Utility by pressing  during server start-up. If USB Flash Drive Emulation
Type is set to Auto, the Flash Drive appears as a floppy drive to the system.

Virtual Flash

Use the left-arrow and right-arrow keys to select Enabled or Disabled.
•

Enable/Disable causes a Detach and an Attach of all Virtual Media
devices from the USB bus.

•

Disable causes the Virtual Flash to be removed and to become unavailable
for use.
NOTE: This field will be read-only if an SD card of a size larger than 256 MB is not
present on AMEA card slot.
NOTE: Dell-branded vFlash media is required for the virtual flash partition.

System Services Configuration
System Services

Use the left-arrow and right-arrow keys to select Enabled or Disabled. If
enabled, certain iDRAC6 features can be configured through the Unified
Server Configuration (USC). For more information, see the Unified Server
Configurator User Guide, available on the Dell Support Website at
support.dell.com.
NOTE: Modifying this option restarts the server when you Save and Exit to apply
the new settings.

272

Using the iDRAC6 Configuration Utility

Cancel System Services

Use the left-arrow and right-arrow keys to select Yes or No.
When you select Yes, all Unified Server Configurator sessions are closed,
and the server restarts when you Save and Exit to apply the new settings.

LAN User Configuration
The LAN user is the iDRAC6 administrator account, which is root by default.
Press  to display the LAN User Configuration submenu. When you
have finished configuring the LAN user, press  to return to the
previous menu.
Table 16-2.

Lan User Configuration Screen

Item

Description

Account Access

Select Enabled to enable the administrator account.
Select Disabled to disable the administrator account.

Account Privilege

Select between Admin, User, Operator, and No Access.

Account User Name Press  to edit the user name and press  when
you have finished. The default user name is root.
Enter Password

Enter the new password for the administrator account.
The characters are not echoed on the display as you enter them.

Confirm Password

Re-enter the new password for the administrator account.
If the characters you enter do not match the characters you
entered in the Enter Password field, a message displays and
you must re-enter the password.

Reset to Default
Use the Reset to Default menu item to reset all of iDRAC6 configuration
items to the factory defaults. This may be required, for example, if you have
forgotten the administrative user password or if you want to reconfigure
iDRAC6 from the default settings.
NOTE: In the default configuration, iDRAC6 networking is disabled. You cannot
reconfigure the iDRAC6 over the network until you have enabled the iDRAC6
network in the iDRAC6 Configuration Utility.

Using the iDRAC6 Configuration Utility

273

Press  to select the item. The following warning message appears:
Resetting to factory defaults will restore remote NonVolatile user settings. Continue?
< NO (Cancel)

>

< YES (Continue) >
To reset iDRAC6 to the defaults, select YES and press .

System Event Log Menu
The System Event Log Menu allows you to view System Event Log (SEL)
messages and to clear the log messages. Press  to display the System
Event Log Menu. The system counts the log entries and then displays the
total number of records and the most recent message. The SEL retains a
maximum of 512 messages.
To view SEL messages, select View System Event Log and press .
To navigate:
•

Use the left-arrow key to move to the previous (older) message and the
right-arrow key to move to the next (newer) message.

•

Enter a specific record number to jump to that record.

Press  to exit the System Event Log.
NOTE: You can only clear the SEL in the iDRAC6 Configuration Utility or in the
iDRAC6 Web-based interface.
To clear the SEL, select Clear the System Event Log and press .
When you have finished with the SEL menu, press  to return to the
previous menu.

Exiting the iDRAC6 Configuration Utility
When you have finished making changes to iDRAC6 configuration, press the
 key to display the Exit menu.
Select Save Changes and Exit and press  to retain your changes.
Select Discard Changes and Exit and press  to ignore any changes
you made.
Select Return to Setup and press  to return to the iDRAC6
Configuration Utility.
274

Using the iDRAC6 Configuration Utility

Recovering and Troubleshooting the
Managed Server
This section explains how to perform tasks related to diagnosing and
troubleshooting a remote managed server using iDRAC6 utilities. It contains
the following subsections:
•

Trouble indications — Helps you to find messages and other system
indications that can lead to a diagnosis of the problem

•

Problem-solving tools — Describes iDRAC6 tools that you can use to
troubleshoot your system

•

Troubleshooting and frequently asked questions — Answers to typical
situations you may encounter

Safety First–For You and Your System
To perform certain procedures in this section, you must work with the chassis,
the PowerEdge server, or other hardware modules. Do not attempt to service
the system hardware except as explained in this guide and elsewhere in your
system documentation.
CAUTION: Many repairs may only be done by a certified service technician. You
should only perform troubleshooting and simple repairs as authorized in your
product documentation, or as directed by online or telephone service and support
team. Damage due to servicing that is not authorized by Dell is not covered by your
warranty. Read and follow the safety instructions that came with the product.

Recovering and Troubleshooting the Managed Server

275

Trouble Indicators
This section describes indications that there may be a problem with
your system.

LED Indicators
LEDs on the chassis or on components installed in the chassis are generally
the first indicators of system trouble. The following components and modules
have status LEDs:
•

Chassis LCD display

•

Servers

•

Fans

•

CMCs

•

I/O modules

•

Power supplies

The single LED on the chassis LCD summarizes the status of all of the
components in the system. A solid blue LED on the LCD indicates that no
fault conditions have been detected in the system. A blinking amber LED on
the LCD indicates that one or more fault conditions have been detected.
If the chassis LCD has a blinking amber LED, you can use the LCD menu to
locate the component that has a fault. See the Dell CMC Firmware User
Guide for help using the LCD.
Table 17-1 describes the meanings of the LED on the PowerEdge Server:
Table 17-1. Server LED Indicators
LED indicator

Meaning

solid green

The server is powered on. Absence of the green LED means the
server is not powered on.

solid blue

iDRAC6 is healthy.

flashing amber

iDRAC6 has detected a fault condition or may be in the process
of updating firmware.

flashing blue

A user has activated the locator ID for this server.

276

Recovering and Troubleshooting the Managed Server

Hardware Trouble Indicators
Indications that a module has a hardware problem include the following:
•

Failure to power up

•

Noisy fans

•

Loss of network connectivity

•

Battery, temperature, voltage, or power monitoring sensor alerts

•

Hard drive failures

•

USB media failure

•

Physical damage caused by dropping, water, or other external stress

When these kinds of problems occur, you can try to correct the problem
using these strategies:
•

Reseat the module and restart it

•

Try inserting the module into a different bay in the chassis

•

Try replacing hard drives or USB keys

•

Reconnect or replace the power and network cables

If these steps do not correct the problem, consult the Hardware Owner’s
Manual for specific troubleshooting information for the hardware device.

Other Trouble Indicators
Table 17-2.

Trouble Indicators

Look for:

Action:

Alert messages from the systems
management software

See the systems management software
documentation.

Messages in the System Event Log

See "Checking the System Event Log
(SEL)."

Messages in the start-up POST codes

See "Checking the Post Codes."

Messages on the last crash screen

See "Viewing the Last System Crash
Screen."

Alert Messages on the Server Status
Screen in the LCD

See "Checking the Server Status Screen
for Error Messages."

Messages in the iDRAC6 Log

See "Viewing the iDRAC6 Log."

Recovering and Troubleshooting the Managed Server

277

Problem Solving Tools
This section describes iDRAC6 utilities you can use to diagnose problems
with your system, especially when you are trying to solve problems remotely.
•

Checking the system health

•

Checking the System Event Log for error messages

•

Checking the POST codes

•

Viewing the last crash screen

•

Checking the Server Status Screen on the LCD for Error Messages

•

Viewing the iDRAC6 log

•

Accessing system information

•

Identifying the managed server in the chassis

•

Using the diagnostics console

•

Managing power on a remote system

Checking the System Health
When you log in to the iDRAC6 Web interface, the first screen displayed
describes the health of the system components. Table 17-3 describes the
meaning of the system health indicators.
Table 17-3. System Health Indicators
Indicator Description
A green check mark indicates a healthy (normal) status condition.
A yellow triangle containing an exclamation point indicates a warning
(noncritical) status condition.
A red X indicates a critical (failure) status condition.
A question mark icon indicates that the status is unknown.

Click any component on the Health screen to see information about the
component. Sensor readings are displayed for batteries, temperatures,
voltages, and power monitoring, helping to diagnose some types of problems.
The iDRAC6 and CMC information screens provide useful current status and
configuration information.
278

Recovering and Troubleshooting the Managed Server

Checking the System Event Log (SEL)
The SEL Log screen displays messages for events that occur on the
managed server.
To view the System Event Log, perform the following steps:
1 Click System and then click the Logs tab.
2 Click System Event Log to display the System Event Log screen.
The System Event Log screen displays a system health indicator
(see Table 17-3), a time stamp, and a description of the event.
3 Click the appropriate System Event Log button to continue
(see Table 17-4).
Table 17-4.

SEL Buttons

Button

Action

Print

Prints the SEL in the sort order that it appears in the window.

Clear Log Clears the SEL.

NOTE: The Clear Log button appears only if you have Clear Logs permission.
Save As

Opens a pop-up window that enables you to save the SEL to a directory of
your choice.

NOTE: If you are using Internet Explorer and encounter a problem when
saving, be sure to download the Cumulative Security Update for Internet
Explorer, located on the Microsoft® Support website at
support.microsoft.com.
Refresh

Reloads the SEL screen.

Checking the Post Codes
The Post Codes screen displays the last system post code prior to booting the
operating system. Post codes are progress indicators from the system BIOS,
indicating various stages of the boot sequence from Power on Reset, and allow
you to diagnose any faults related to system boot-up.
NOTE: View the text for POST code message numbers in the LCD display or in the
Hardware Owner’s Manual.

Recovering and Troubleshooting the Managed Server

279

To view the Post Codes, perform the following steps:
1 Click System, the Logs tab, and then Post Codes.
The Post Codes screen displays a system health indicator (see Table 17-3),
a hexadecimal code, and a description of the code.
2 Click the appropriate Post Code button to continue (see Table 17-5).
Table 17-5. Post Code Buttons
Button

Action

Print

Prints the Post Codes screen.

Refresh

Reloads the Post Codes screen.

Viewing the Last System Crash Screen
NOTE: The last crash screen feature must be configured in the Server Administrator
and in the iDRAC6 Web interface. See "Configuring the Managed Server to Capture
the Last Crash Screen" for instructions on configuring this feature.

The Last Crash Screen screen displays the most recent crash screen, which
includes information about the events that occurred before the system crash.
The last system crash image is saved in the iDRAC6 persistent store and is
remotely accessible.
To view the Last Crash Screen screen, perform the following steps:
•

Click System, the Logs tab, and then Last Crash.

The Last Crash Screen screen provides the buttons shown in Table 17-6:
NOTE: The Save and Delete buttons do not appear if there is no saved crash screen.

280

Recovering and Troubleshooting the Managed Server

Table 17-6.

Last Crash Screen Buttons

Button

Action

Print

Prints the Last Crash Screen screen.

Save

Opens a pop-up window that enables you to save the Last Crash Screen to a
directory of your choice.

Delete

Deletes the Last Crash Screen screen.

Refresh Reloads the Last Crash Screen screen.

NOTE: Due to fluctuations in the Auto Recovery timer, the Last Crash Screen may
not be captured when the System Reset Timer is configured with a value that is too
high. The default setting is 480 seconds. Use Server Administrator or IT Assistant to
set the System Reset Timer to 60 seconds and ensure that the Last Crash Screen
functions properly. See "Configuring the Managed Server to Capture the Last Crash
Screen" for additional information.

Viewing the Most Recent Boot Sequences
If you experience boot problems, you can view the screen activity of what
happened during the last three boot sequences from the Boot Capture
screen. Playback of the boot screens occurs at a rate of 1 frame per second.
Table 17-7 lists the control actions available.
NOTE: You must have administrator privileges to view playback of the Boot Capture
sequences.
Table 17-7.

Boot Capture Options

Button/Option

Description

Select the boot
sequence

Allows you to select the boot sequence to load and play.
• Boot Capture 1 — Loads the most recent boot sequence.
• Boot Capture 2 — Loads the (second most recent) boot
sequence that occurred prior to Boot Capture 1.
• Boot Capture 3 — Loads the (third most recent) boot
sequence that occurred prior to Boot Capture 2.

Save As

Creates a compressed .zip file that contains all boot capture
images of the current sequence. The user must have
administrator privileges to perform this action.

Recovering and Troubleshooting the Managed Server

281

Table 17-7. Boot Capture Options (continued)
Button/Option

Description

Previous Screen

Takes you to previous screen, if any, in the replay console.

Play

Starts the screenplay from current screen in the replay console.

Pause

Pauses the screenplay on the current screen being displayed in
the replay console.

Stop

Stops the screenplay and loads the first screen of that boot
sequence.

Next Screen

Takes you to next screen, if any, in the replay console.

Print

Prints the Boot Capture image that appears on the screen.

Refresh

Reloads the Boot Capture screen.

Checking the Server Status Screen for Error Messages
When a flashing amber LED is lit, and a particular server has an error,
the main Server Status Screen on the LCD will highlight the affected server
in orange. Use the LCD navigation buttons to highlight the affected server,
then click the center button. Error and warning messages will be displayed on the
second line. The following table lists all of the error messages and their severity.
Table 17-8. Server Status Screen
Severity

Message

Cause

Warning

System Board Ambient Temp:
Temperature sensor for System
Board, warning event

Server ambient temperature
crossed a warning threshold

Critical

System Board Ambient Temp:
Temperature sensor for System
Board, failure event

Server ambient temperature
crossed a failure threshold

Critical

System Board CMOS Battery:
Battery sensor for System Board,
failed was asserted

CMOS battery is not present or
has no voltage

Warning

System Board System Level:
Current crossed a warning
Current sensor for System Board, threshold
warning event

282

Recovering and Troubleshooting the Managed Server

Table 17-8.

Server Status Screen (continued)

Severity

Message

Cause

Critical

System Board System Level:
Current crossed a failure
Current sensor for System Board, threshold
failure event

Critical

CPU : Voltage sensor for
CPU, state asserted
was asserted

Critical

System Board : Voltage sensor for
System Board, state asserted was
asserted

Critical

CPU : Voltage sensor for
CPU, state asserted
was asserted

Critical

CPU Status:
Processor sensor for
CPU Status:
CPU overheated
Processor sensor for
CPU, thermal tripped
was asserted

Critical

CPU Status:
Processor sensor for
CPU Status:
Processor sensor for
CPU, presence was
deasserted

Required CPU is missing or
not present

Critical

System Board Video Riser:
Required module was removed
Module sensor for System Board,
device removed was asserted

CPU failure

Recovering and Troubleshooting the Managed Server

283

Table 17-8. Server Status Screen (continued)
Severity

Message

Cause

Critical

Mezz B Status:
Add-in Card sensor for Mezz
B, install error
was asserted

Incorrect Mezzanine card
installed for IO fabric

Critical

Mezz C Status:
Add-in Card sensor for Mezz
C, install error
was asserted

Incorrect Mezzanine card
installed for I/O fabric

Critical

Backplane Drive :
Drive Slot sensor for Backplane,
drive removed

Storage drive was removed

Critical

Backplane Drive :
Drive Slot sensor for Backplane,
drive fault was asserted

Storage drive failed

Critical

System Board PFault Fail Safe:
This event is generated when
Voltage sensor for System Board, the system board voltages are
state asserted was asserted
not at normal levels

Critical

System Board OS Watchdog:
The iDRAC6 watchdog timer
Watchdog sensor for System
expired and no action is set
Board, timer expired was asserted

Critical

System Board OS Watchdog:
Watchdog sensor for System
Board, reboot was asserted

The iDRAC6 watchdog
detected that the system has
crashed (timer expired because
no response was received from
Host) and the action is set to
reboot

Critical

System Board OS Watchdog:
Watchdog sensor for System
Board, power off was asserted

The iDRAC6 watchdog
detected that the system has
crashed (timer expired because
no response was received from
Host) and the action is set to
power off

284

Recovering and Troubleshooting the Managed Server

Table 17-8.

Server Status Screen (continued)

Severity

Message

Cause

Critical

System Board OS Watchdog:
Watchdog sensor for System
Board, power cycle was asserted

The iDRAC6 watchdog
detected that the system has
crashed (timer expired because
no response was received from
Host) and the action is set to
power cycle

Critical

System Board SEL: Event Log
sensor for System Board, log full
was asserted

The SEL device detects that
only one entry can be added to
the SEL before it is full

Warning

ECC Corr Err: Memory sensor,
correctable ECC
(  ) was
asserted

Correctable ECC errors
reached a critical rate

Critical

ECC Uncorr Err: Memory sensor, An uncorrectable ECC error
uncorrectable ECC
was detected
(  ) was
asserted

Critical

I/O Channel Chk: Critical Event A critical interrupt is generated
sensor, I/O channel check NMI
in the I/O Channel
was asserted

Critical

PCI Parity Err: Critical Event
sensor, PCI PERR was asserted

Parity error was detected on the
PCI bus

Critical

PCI System Err: Critical Event
sensor, PCI SERR
( ) was asserted

PCI error detected by device

Critical

SBE Log Disabled: Event Log
Single bit error logging is
sensor, correctable memory error disabled when too many SBE
logging disabled was asserted
get logged

Critical

Logging Disabled: Event Log
All error logging is disabled
sensor, all event logging disabled
was asserted

Non-Recoverable CPU Protocol Err:
Processor sensor, transition to
non-recoverable was asserted

The processor protocol entered
a non-recoverable state

Recovering and Troubleshooting the Managed Server

285

Table 17-8. Server Status Screen (continued)
Severity

Message

Cause

Non-Recoverable CPU Bus PERR: Processor sensor, The processor bus PERR
transition to non-recoverable
entered a non-recoverable state
was asserted
Non-Recoverable CPU Init Err: Processor sensor,
transition to non-recoverable
was asserted

The processor initialization
entered a non-recoverable state

Non-Recoverable CPU Machine Chk: Processor
sensor, transition to
non-recoverable was asserted

The processor machine check
entered a non-recoverable state

Critical

Memory Spared: Memory sensor, Memory spare is no longer
redundancy lost
redundant
(  ) was
asserted

Critical

Memory Mirrored: Memory
sensor, redundancy lost
(  ) was
asserted

Mirrored memory is no longer
redundant

Critical

Memory RAID: Memory sensor,
redundancy lost
(  ) was
asserted

RAID Memory is no longer
redundant

Warning

Memory Added: Memory sensor, Added memory module was
presence (  ) removed
was deasserted

Warning

Memory Removed: Memory
sensor, presence (  ) was deasserted

Critical

Memory Cfg Err: Memory sensor, Memory configuration is
incorrect for the system
configuration error
(  ) was
asserted

Warning

Mem Redun Gain: Memory
sensor, redundancy degraded
(  ) was
asserted

286

Memory module was removed

Memory redundancy is
downgraded but not lost

Recovering and Troubleshooting the Managed Server

Table 17-8.

Server Status Screen (continued)

Severity

Message

Cause

Critical

PCIE Fatal Err: Critical Event
Fatal error is detected on the
sensor, bus fatal error was asserted PCIE bus

Critical

Chipset Err: Critical Event
sensor, PCI PERR was asserted

Warning

Mem ECC Warning: Memory
Correctable ECC errors have
sensor, transition to non-critical increased from a normal rate
from OK ( )
was asserted

Critical

Mem ECC Warning: Memory
Correctable ECC errors have
sensor, transition to critical from reached a critical rate
less severe (  )
was asserted

Critical

POST Err: POST sensor,
No memory installed

Critical

POST Err: POST sensor, Memory Memory detected but is not
configuration error
configurable

Critical

POST Err: POST sensor,
Unusable memory error

Memory configured but
not usable

Critical

POST Err: POST sensor,
Shadow BIOS failed

System BIOS shadow failure

Critical

POST Err: POST sensor,
CMOS failed

CMOS failure

Critical

POST Err: POST sensor,
DMA controller failed

DMA controller failure

Critical

POST Err: POST sensor,
Interrupt controller failed

Interrupt controller failure

Critical

POST Err: POST sensor,
Timer refresh failed

Timer refresh failure

Critical

POST Err: POST sensor,
Programmable interval
timer error

Programmable interval
timer error

Critical

POST Err: POST sensor,
Parity error

Parity error

Chip error is detected

No memory detected on board

Recovering and Troubleshooting the Managed Server

287

Table 17-8. Server Status Screen (continued)
Severity

Message

Cause

Critical

POST Err: POST sensor,
SIO failed

SIO failure

Critical

POST Err: POST sensor,
Keyboard controller failed

Keyboard controller failure

Critical

POST Err: POST sensor,
System management interrupt
initialization failed

System Management Interrupt
initialization failure

Critical

POST Err: POST sensor,
BIOS shutdown test failed

BIOS shutdown test failure

Critical

POST Err: POST sensor,
BIOS POST memory test failed

BIOS POST memory test
failure

Critical

POST Err: POST sensor,
Dell remote access controller
configuration failed

Dell Remote Access Controller
configuration failure

Critical

POST Err: POST sensor,
CPU configuration failed

CPU configuration failure

Critical

POST Err: POST sensor,
Incorrect memory configuration

Incorrect memory
configuration

Critical

POST Err: POST sensor,
POST failure

General failure after video

Critical

Hdwar version err: Version
Change sensor, hardware
incompatibility was asserted

Incompatible hardware was
detected

Critical

Hdwar version err: Version
Hardware is incompatible with
the firmware
Change sensor, hardware
incompatibility (BMC firmware)
was asserted

Critical

CPU and firmware not
Hdwar version err: Version
Change sensor, hardware
compatible
incompatibility (BMC firmware
and CPU mismatch) was asserted

288

Recovering and Troubleshooting the Managed Server

Table 17-8.

Server Status Screen (continued)

Severity

Message

Cause

Critical

Mem Overtemp: Memory sensor, Memory module overheating
correctable ECC  was asserted

Critical

Mem Fatal SB CRC: Memory
sensor, uncorrectable ECC
was asserted

South bridge memory failed

Critical

Mem Fatal NB CRC: Memory
sensor, uncorrectable ECC
was asserted

North bridge memory failed

Critical

WatchDog Timer: Watchdog
sensor, reboot was asserted

Watch dog timer caused
system to reboot

Critical

WatchDog Timer: Watchdog
Watch dog timer expired but
sensor, timer expired was asserted no action taken

Warning

Link Tuning: Version Change
sensor, successful software or
F/W change was deasserted

Failed to update link tuning
setting for proper NIC operation

Warning

Link Tuning: Version Change
sensor, successful hardware
change 
was deasserted

Failed to update link tuning
setting for proper NIC operation

Critical

LinkT/FlexAddr: Link Tuning
sensor, failed to program virtual
MAC address (Bus # Device #
Function #) was asserted

Flex address could not be
programmed for this device

Critical

LinkT/FlexAddr: Link Tuning
Option ROM does not support
sensor, device option ROM failed Flex address or linking tuning
to support link tuning or flex
address (Mezz )
was asserted

Critical

LinkT/FlexAddr: Link Tuning
Failed to obtain linking tuning
sensor, failed to get link tuning or or Flex address information
from BMC/iDRAC6
flex address data from BMC/
iDRAC6 was asserted

Recovering and Troubleshooting the Managed Server

289

Table 17-8. Server Status Screen (continued)
Severity

Message

Cause

Critical

LinkT/FlexAddr: Link Tuning
sensor, device option ROM failed
to support link tuning or flex
address (Mezz XX) was asserted

This event is generated when
the PCI device Option ROM
for a NIC does not support
link tuning or the Flex
addressing feature

Critical

LinkT/FlexAddr: Link Tuning
sensor, failed to program the
virtual MAC address
() was asserted

This event is generated when
the BIOS fails to program the
virtual MAC address on the
given NIC device

Critical

I/O Fatal Err: Fatal IO Group
sensor, fatal IO error
()

This event is generated in
association with a CPU IERR
and indicates which device
caused the CPU IERR

Warning

PCIE NonFatal Er: Non Fatal I/O This event is generated in
Group sensor, PCIe error
association with a CPU IERR
()

Viewing the iDRAC6 Log
The iDRAC6 Log is a persistent log maintained in iDRAC6 firmware.
The log contains a list of user actions (such as log in, log out, and security
policy changes) and alerts issued by iDRAC6. The oldest entries are
overwritten when the log becomes full.
Where the System Event Log (SEL) contains records of events that occur in
the managed server, the iDRAC Log contains records of events that occur in
iDRAC6.
To access the iDRAC Log, perform the following steps:
•

Click System→ Remote Access→ iDRAC and then click iDRAC Log.

The iDRAC Log provides the information in Table 17-9.

290

Recovering and Troubleshooting the Managed Server

Table 17-9.

iDRAC6 Log Information

Field

Description

Date/Time

The date and time (for example, Dec 19 16:55:47).
iDRAC6 sets its clock from the managed server’s clock. When iDRAC6
initially starts and is unable to communicate with the managed server,
the time is displayed as the string System Boot.

Source

The interface that caused the event.

Description A brief description of the event and the user name that logged in to
iDRAC6.

Using the iDRAC6 Log Buttons

The iDRAC Log screen provides the following buttons (see Table 17-10).
Table 17-10.

iDRAC6 Log Buttons

Button

Action

Print

Prints the iDRAC Log screen.

Clear Log

Clears the iDRAC Log entries.

NOTE: The Clear Log button only appears if you have Clear Logs
permission.
Save As

Opens a pop-up window that enables you to save the iDRAC Log to a
directory of your choice.

NOTE: If you are using Internet Explorer and encounter a problem when
saving, be sure to download the Cumulative Security Update for Internet
Explorer, located on the Microsoft Support website at
support.microsoft.com.
Refresh

Reloads the iDRAC Log screen.

Viewing System Information
The System Summary screen displays information about the following system
components:
•

Main system enclosure

•

Integrated Dell Remote Access Controller

To access the system information, click System→ Properties.
Recovering and Troubleshooting the Managed Server

291

Main System Enclosure

Table 17-11 and Table 17-12 describe the main system enclosure properties.
Table 17-11. System Information Fields
Field

Description

Description

Provides a system description.

BIOS Version

Lists the system BIOS version.

Service Tag

Lists the system Service Tag number.

Host Name

Provides the host system’s name.

OS Name

Lists the operating system running on the system.

Table 17-12. Auto Recovery Fields
Field

Description

Recovery Action

When a system hang is detected, iDRAC6 can be configured to
perform one of the following actions: No Action, Hard Reset,
Power Down, or Power Cycle.

Initial Countdown The number of seconds after a system hang is detected at which
iDRAC6 will perform a Recovery Action.
Present Countdown The current value, in seconds, of the countdown timer.

Integrated Dell Remote Access Controller

Table 17-13 describes iDRAC6 properties.
Table 17-13. iDRAC6 Information Fields
Field

Description

Date/Time

Provides the current date and time on iDRAC6 in GMT.

Firmware Version

Lists the version of iDRAC6 firmware.

Firmware Updated Lists the date the firmware was last updated. The date is
displayed in UTC format, for example: Tue, 8 May 2007,
22:18:21 UTC.

292

Recovering and Troubleshooting the Managed Server

Table 17-13.

iDRAC6 Information Fields (continued)

Field

Description

IP Address

The 32-bit address that identifies the network interface.
The value is displayed in a dot separated format,
such as 143.166.154.127.

Gateway

The IP Address of the gateway that acts as a bridge to
other networks. This value is in a dot separated format,
such as 143.166.150.5.

Subnet Mask

The subnet mask identifies the parts of the IP Address that
make up the Extended Network Prefix and the Host Number.
The value is displayed in a dot separated format,
such as 255.255.0.0.

MAC Address

The Media Access Control (MAC) Address that uniquely
identifies each NIC in a network, for example 00-00-0c-ac-08.
This is a Dell-assigned ID and cannot be edited.

DHCP Enabled

Enabled indicates that the Dynamic Host Configuration
Protocol (DHCP) is enabled.
Disabled indicates that DHCP is not enabled.

Identifying the Managed Server in the Chassis
The PowerEdge M1000e chassis holds up to sixteen servers. To locate a
specific server in the chassis, you can use the iDRAC6 Web interface to turn
on a blue flashing LED on the server. When you turn on the LED, you can
specify the number of seconds that you want the LED to flash to ensure that
you can reach the chassis while the LED is still flashing. Entering 0 leaves the
LED flashing until you disable it.
To identify the server:
1 Click System→ Remote Access→ iDRAC→ Troubleshooting.
2 On the Identify screen, check Identify Server.
3 In the Identify Server Timeout field, enter the number of seconds that you
want the LED to blink. Enter 0 if you want the LED to remain flashing
until you disable it.
4 Click Apply.
A blue LED on the server will flash for the number of seconds you specified.

Recovering and Troubleshooting the Managed Server

293

If you entered 0 to leave the LED flashing, follow these steps to disable it:
1 Click System→ Remote Access→ iDRAC→ Troubleshooting.
2 On the Identify screen, uncheck Identify Server.
3 Click Apply.

Using the Diagnostics Console
iDRAC6 provides a standard set of network diagnostic tools (see Table 17-14)
that are similar to the tools included with Microsoft® Windows® or
Linux-based systems. Using the iDRAC6 Web interface, you can access the
network debugging tools.
To access the Diagnostics Console screen, perform the following steps:
1 Click System→ iDRAC→ Troubleshooting.
2 Click the Diagnostics tab.
Table 17-14 describes the commands that can be entered on the Diagnostics
Console screen. Enter a command and click Submit. The debugging results
appear in the Diagnostics Console screen.
Click the Clear button to clear the results displayed by the previous
command.
To refresh the Diagnostics Console screen, click Refresh.
Table 17-14. Diagnostic Commands
Command

Description

arp

Displays the contents of the Address Resolution Protocol (ARP)
table. ARP entries may not be added or deleted.

ifconfig

Displays the contents of the network interface table.

netstat

Prints the content of the routing table.

ping


Verifies that the destination IP address is reachable from iDRAC6
with the current routing-table contents. A destination IP address
must be entered in the field to the right of this option. An Internet
control message protocol (ICMP) echo packet is sent to the
destination IP address based on the current routing-table contents.

gettracelog

Displays the iDRAC6 trace log. See "gettracelog" for more
information.

294

Recovering and Troubleshooting the Managed Server

Managing Power on a Remote System
iDRAC6 enables you to remotely perform several power management actions
on the managed server. Use the Power Management screen to perform an
orderly shutdown through the operating system when rebooting and powering
on and off.
NOTE: You must have Execute Server Action Commands permission to perform
power management actions. See "Adding and Configuring iDRAC6 Users" for help
configuring user permissions.
1 Click System, then click the Power Management tab.
2 Select a Power Control Action, for example Reset System (warm boot).
Table 17-15 provides information about Power Control Actions.
3 Click Apply to perform the selected action.
4 Click the appropriate button to continue. See Table 17-15.
Table 17-15.

Power Control Actions

Power On
System

Turns on the system power (equivalent to pressing the power button
when the system power is off).

Powers Off
System

Turns off the system power (equivalent to pressing the power button
when the system power is on).

NMI
Sends a high-level interrupt to the operating system, which causes
(Non-Masking the system to halt operation to allow for critical diagnostic or
Interrupt)
troubleshooting activities.
Graceful
Shutdown

Attempts to cleanly shut down the operating system, then powers off
the system. It requires an ACPI (Advanced Configuration and Power
Interface) aware operating system, which allows for system directed
power management.

NOTE: A graceful shutdown of the server operating system may not be
possible when the server software stops responding, or if you are not
logged as an administrator at a local Windows console. In these cases,
you must specify a forced reboot instead of a graceful shutdown of
Windows. In addition, depending on the version of the Windows OS,
there might be a policy configured around the shutdown process that
modifies shutdown behavior when triggered from iDRAC6. See
Microsoft’s documentation for the local computer policy “Shutdown:
Allow system to be shut down without having to login.”

Recovering and Troubleshooting the Managed Server

295

Table 17-15. Power Control Actions (continued)
Reset System
(warm boot)

Reboots the system without powering off (warm boot).

Power Cycle
System

Powers off, then reboots the system (cold boot).

Table 17-16. Power Management Buttons
Button

Action

Print

Prints the Power Management values that appear on the screen.

Refresh

Reloads the Power Management screen.

Apply

Saves any new settings that you make while viewing the Power
Management screen.

Troubleshooting and Frequently Asked Questions
Table 17-17 contains frequently asked questions about troubleshooting
issues.
Table 17-17. Frequently Asked Questions/Troubleshooting
Question

Answer

The LED on the
server is blinking
amber.

Check the SEL for messages and then clear the SEL to stop the
blinking LED.
From the iDRAC6 Web interface:
• See "Checking the System Event Log (SEL)"
From SM-CLP:
• See "SEL Management"
From the iDRAC6 Configuration Utility:
• See "System Event Log Menu"

There is a
blinking blue
LED on the
server.

296

A user has activated the locator ID for the server. This is a signal
to help them identify the server in the chassis. See "Identifying
the Managed Server in the Chassis" for information about
this feature.

Recovering and Troubleshooting the Managed Server

Table 17-17.

Frequently Asked Questions/Troubleshooting (continued)

Question

Answer

How can I find
the IP address of
iDRAC6?

From the CMC Web interface:
1 Click Chassis→ Servers, then click the Setup tab.
2 Click Deploy.
3 Read the IP address for your server from the table that is
displayed.
From the iKVM:
• Reboot the server and enter the iDRAC6 Configuration Utility
by pressing .
OR
• Watch for the IP address to display during BIOS POST.
OR
• Select the "Dell CMC" console in the OSCAR to log in to the
CMC through a local serial connection.
CMC RACADM commands can be issued from this connection.
Refer to the CMC Firmware User Guide for a complete list of the
CMC RACADM subcommands.
You can also use the local RACADM getsysinfo command to view
the iDRAC6 IP address.
For example:
$ racadm getniccfg -m server-1
DHCP Enabled
IP Address
Subnet Mask
Gateway

=
=
=
=

1
192.168.0.1
255.255.255.0
192.168.0.1

From local RACADM:
1 Enter the following command at a command prompt:
racadm getsysinfo
From the LCD:
1 On the Main Menu, highlight Server and press the check button.
2 Select the server whose IP address you seek and press the
check button.

Recovering and Troubleshooting the Managed Server

297

Table 17-17. Frequently Asked Questions/Troubleshooting (continued)
Question

Answer

How can I find
the IP address of
the CMC?

From the iDRAC6 Web interface:
• Click System→ Remote Access→ CMC.
The CMC IP address is displayed on the Summary screen.
OR
• Select the "Dell CMC" console in the OSCAR to log in to the
CMC through a local serial connection. CMC RACADM
commands can be issued from this connection. Refer to the
CMC Firmware User Guide for a complete list of the CMC
RACADM subcommands.
$ racadm getniccfg -m chassis
NIC Enabled
DHCP Enabled
Static IP Address
Static Subnet Mask
Static Gateway
Current IP Address
Current Subnet Mask
Current Gateway
Speed
Duplex

=
=
=
=
=
=
=
=
=
=

1
1
192.168.0.120
255.255.255.0
192.168.0.1
10.35.155.151
255.255.255.0
10.35.155.1
Autonegotiate
Autonegotiate

The iDRAC6
network
connection is
not working.

• Ensure the LAN cable is connected to the CMC.

I inserted the
server into the
chassis and
pressed the
power button,
but nothing
happened.

• iDRAC6 requires about 30 seconds to initialize before the server
can power up. Wait for 30 seconds and then press the power
button again.

298

• Ensure the iDRAC6 LAN is enabled.

• Check the CMC power budget. The chassis power budget may
be exceeded.

Recovering and Troubleshooting the Managed Server

Table 17-17.

Frequently Asked Questions/Troubleshooting (continued)

Question

Answer

I have forgotten
the iDRAC6
administrative
user name and
password.

You must restore iDRAC6 to its default settings.
1 Reboot the server and press  when prompted to
enter the iDRAC6 Configuration Utility.
2 On the Configuration Utility menu, highlight Reset to Default
and press .
For more information, see "Reset to Default."

How can I change
the name of the
slot for my server?

1 Log in to the CMC Web interface.
2 Open the Chassis tree and click Servers.
3 Click the Setup tab.
4 Enter the new name for the slot in the row for your server.
5 Click Apply.

When starting a
console
redirection
session from the
iDRAC6 Web
interface,
an ActiveX
security popup
appears.
When I start a
console
redirection
session, the
viewer screen is
blank.

iDRAC6 may not be a trusted site from the client browser.
To prevent the security popup from appearing every time you
begin a console redirection session, add iDRAC6 to the trusted
site list:
1 Click Tools→ Internet Options…→ Security→ Trusted sites.
2 Click Sites and enter the IP address or the DNS name of iDRAC6.
3 Click Add.
If you have Virtual Media privilege but not Console Redirection
privilege, you are able to start the viewer so that you can access
the virtual media feature, but the managed server’s console
will not display.

Recovering and Troubleshooting the Managed Server

299

Table 17-17. Frequently Asked Questions/Troubleshooting (continued)
Question

Answer

iDRAC6 does not Remove and reinsert the server.
boot.
Check the CMC Web interface to see if iDRAC6 appears as an
upgradable component. If it does, follow the instructions in
"Updating iDRAC6 Firmware Using the CMC."
If this does not correct the problem, contact Technical Support.
When attempting
to boot the
managed server,
the power
indicator is green,
but there is no
POST or no video
at all.

300

This can happen if any of the following conditions is true:
• Memory is not installed or is inaccessible.
• The CPU is not installed or is inaccessible.
• The video riser card is missing or improperly connected.
Also, look for error messages in the iDRAC6 log from the iDRAC6
Web interface or from the LCD.

Recovering and Troubleshooting the Managed Server

RACADM Subcommand Overview
This section provides descriptions of the subcommands that are available in
the RACADM command line interface.

help
Table A-1 describes the help command.
Table A-1.

Help Command

Command

Definition

help

Lists all of the subcommands available to use with
racadm and provides a short description for each.

Synopsis
racadm help
racadm help 

Description
The help subcommand lists all of the subcommands that are available when
using the racadm command along with a one-line description. You may also
enter a subcommand after help to get the syntax for a specific subcommand.

Output
The racadm help command displays a complete list of subcommands.
The racadm help  command displays information for the
specified subcommand only.

Supported Interfaces
•

Local RACADM
RACADM Subcommand Overview

301

config
Table A-2 describes the config and getconfig subcommands.
Table A-2.

config/getconfig

Subcommand

Definition

config

Configures iDRAC6.

getconfig

Gets iDRAC6 configuration data.

Synopsis
racadm config [-c|-p] -f 
racadm config -g  -o  [-i
] 

Supported Interfaces
•

Local RACADM

Description
The config subcommand allows you to set iDRAC6 configuration parameters
individually or to batch them as part of a configuration file. If the data is
different, that iDRAC6 object is written with the new value.
Input

Table A-3 describes the config subcommand options.
Table A-3.

config Subcommand Options and Descriptions

Option Description
-f

The -f  option causes config to read the contents of the file
specified by  and configure iDRAC6. The file must contain data
in the format specified in "Configuration File Syntax" on page 237.

-p

The -p, or password, option directs config to delete the password entries
contained in the config file -f  after the configuration is complete.

-g

The -g , or group, option must be used with the -o option.
The  specifies the group containing the object that is to be set.

302

RACADM Subcommand Overview

Table A-3.

config Subcommand Options and Descriptions (continued)

Option Description
-o

The -o  , or object, option must be used with the -g
option. This option specifies the object name that is written with the
string .

-i

The -i , or index, option is only valid for indexed groups and can be
used to specify a unique group. The index is specified here by the index
value, not a "named" value.

-c

The -c, or check, option is used with the config subcommand and allows you
to parse the .cfg file to find syntax errors. If errors are found, the line number
and a short description of what is incorrect are displayed. Writes do not occur
to iDRAC6. This option is a check only.

Output

This subcommand generates error output upon encountering either of the
following:
•

Invalid syntax, group name, object name, index, or other invalid
database members

•

RACADM CLI failures

This subcommand returns an indication of how many configuration objects
that were written out of how many total objects were in the .cfg file.
Examples

•

racadm config -g cfgLanNetworking -o
cfgNicIpAddress 10.35.10.110
Sets the cfgNicIpAddress configuration parameter (object) to the value
10.35.10.110. This IP address object is contained in the group
cfgLanNetworking.

•

racadm config -f myrac.cfg
Configures or reconfigures iDRAC6. The myrac.cfg file may be created
with the getconfig command. The myrac.cfg file may also be edited
manually as long as the parsing rules are followed.
NOTE: The myrac.cfg file does not contain passwords. To include passwords
in the file, you must enter them manually. If you want to remove passwords
from the myrac.cfg file during configuration, use the -p option.
RACADM Subcommand Overview

303

getconfig
The getconfig subcommand allows you to retrieve iDRAC6 configuration
parameters individually, or all the iDRAC6 configuration groups may
be retrieved and saved into a file.
Input

Table A-4 describes the getconfig subcommand options.
NOTE: The -f option without a file specification will output the contents of the file to
the terminal screen.
Table A-4.

getconfig Subcommand Options

Option

Description

-f

The -f  option directs getconfig to write the entire iDRAC6
configuration to a configuration file. This file can then be used for batch
configuration operations using the config subcommand.

NOTE: The -f option does not create entries for the cfgIpmiPet and

cfgIpmiPef groups. You must set at least one trap destination to capture the
cfgIpmiPet group to the file.

-g

The -g , or group, option can be used to display the
configuration for a single group. The groupName is the name for the group
used in the racadm.cfg files. If the group is an indexed group, use the -i option.

-h

The -h, or help, option displays a list of all available configuration groups
that you can use. This option is useful when you do not remember exact
group names.

-i

The -i , or index, option is valid only for indexed groups and can
be used to specify a unique group. If -i  is not specified, a value of
1 is assumed for groups, which are tables that have multiple entries. The
index is specified by the index value, not a "named" value.

-o

The -o , or object, option specifies the object name that is
used in the query. This option can be used with the -g option.

-u

The -u , or user name, option can be used to display the
configuration for the specified user. The  option is the login
name for the user.

-v

The -v, or verbose, option displays additional details with the display of the
properties and is used with the -g option.

304

RACADM Subcommand Overview

Output

This subcommand generates error output upon encountering either of the
following:
•

Invalid syntax, group name, object name, index, or other invalid database
members

•

RACADM CLI transport failures

If errors are not encountered, this subcommand displays the contents of the
specified configuration.

Examples
•

racadm getconfig -g cfgLanNetworking
Displays all of the configuration properties (objects) that are contained in
the group cfgLanNetworking.

•

racadm getconfig -f myrac.cfg
Saves all group configuration objects from iDRAC6 to myrac.cfg.

•

racadm getconfig -h
Displays a list of the available configuration groups on iDRAC6.

•

racadm getconfig -u root
Displays the configuration properties for the user named root.

•

racadm getconfig -g cfgUserAdmin -i 2 -v
Displays the user group instance at index 2 with extensive information for
the property values.

Synopsis
racadm getconfig -f 
racadm getconfig -g  [-i ]
racadm getconfig -u 
racadm getconfig -h

Supported Interfaces
•

Local RACADM
RACADM Subcommand Overview

305

getssninfo
Table A-5 describes the getssninfo subcommand.
Table A-5.

getssninfo Subcommand

Subcommand

Definition

getssninfo

Retrieves session information for one or more
currently active or pending sessions from the Session
Manager's session table.

Synopsis
racadm getssninfo [-A] [-u  | *]

Description
The getssninfo command returns a list of users that are connected to
iDRAC6. The summary information provides the following information:
•

Username

•

IP address (if applicable)

•

Session type (for example, SSH or telnet)

•

Consoles in use (for example, Virtual Media or Virtual KVM)

Supported Interfaces
•

Local RACADM

Input
Table A-6 describes the getssninfo subcommand options.
Table A-6.

getssninfo Subcommand Options

Option Description
-A

The -A option eliminates the printing of data headers.

-u

The -u  user name option limits the printed output to only the
detail session records for the given user name. If an asterisk (*) symbol is
given as the user name, all users are listed. Summary information is not
printed when this option is specified.

306

RACADM Subcommand Overview

Examples
•

racadm getssninfo

Table A-7 provides an example of output from the racadm getssninfo
command.
Table A-7.

getssninfo Subcommand Output Example

User

IP Address

Type

Consoles

root

192.168.0.10

Telnet

Virtual KVM

•

racadm getssninfo -A
"root" 143.166.174.19 "Telnet" "NONE"

•

racadm getssninfo -A -u *
"root" "143.166.174.19" "Telnet" "NONE"

•

"bob" "143.166.174.19" "GUI" "NONE"

getsysinfo
Table A-8 describes the racadm getsysinfo subcommand.
Table A-8.

getsysinfo

Command

Definition

getsysinfo

Displays iDRAC6 information, system information,
and watchdog status information.

Synopsis
racadm getsysinfo [-d] [-s] [-w] [-A]

Description
The getsysinfo subcommand displays information related to iDRAC6, the
managed server, and the watchdog configuration.

Supported Interfaces
•

Local RACADM
RACADM Subcommand Overview

307

Input
Table A-9 describes the getsysinfo subcommand options.
Table A-9.

getsysinfo Subcommand Options

Option

Description

-d

Displays iDRAC6 information.

-s

Displays system information

-w

Displays watchdog information

-A

Eliminates the printing of headers/labels.

Output
The getsysinfo subcommand displays information related to iDRAC6, the
managed server, and the watchdog configuration.

Sample Output
RAC Information:
RAC Date/Time
Firmware Version
Firmware Build
Last Firmware Update

=
=
=
=

Wed Aug 22 20:01:33 2007
0.32
13661
Mon Aug 20 08:09:36 2007

Hardware Version
Current IP Address
Current IP Gateway
Current IP Netmask
DHCP Enabled
MAC Address
Current DNS Server 1
Current DNS Server 2
DNS Servers from DHCP
Register DNS RAC Name
DNS RAC Name
Current DNS Domain

=
=
=
=
=
=
=
=
=
=
=
=

NA
192.168.0.120
192.168.0.1
255.255.255.0
1
00:14:22:18:cd:f9
10.32.60.4
10.32.60.5
1
1
iDRAC-783932693338
us.dell.com

308

RACADM Subcommand Overview

System Information:
System Model
System BIOS Version
BMC Firmware Version
Service Tag
Host Name
OS Name
Power Status

=
=
=
=
=
=
=

Watchdog Information:
Recovery Action
Present countdown value
Initial countdown value

= None
= 0 seconds
= 0 seconds

PowerEdge M600
0.2.1
0.32
48192
dell-x92i38xc2n
OFF

Examples
•

racadm getsysinfo -A -s
"System Information:" "PowerEdge M600" "0.2.1"
"0.32" "48192" "dell-x92i38xc2n" "" "ON"

•

racadm getsysinfo -w -s

System Information:
System Model
System BIOS Version
BMC Firmware Version
Service Tag
Host Name
OS Name
Power Status
Watchdog Information:
Recovery Action
Present countdown value
Initial countdown value

= PowerEdge M600
= 0.2.1
= 0.32
= 48192
= dell-x92i38xc2n
=
= ON

= None
= 0 seconds
= 0 seconds

RACADM Subcommand Overview

309

Restrictions
The Hostname and OS Name fields in the getsysinfo output display accurate
information only if Dell OpenManage is installed on the managed server. If
OpenManage is not installed on the managed server, these fields may be
blank or inaccurate.

getractime
Table A-10 describes the getractime subcommand.
Table A-10. getractime
Subcommand

Definition

getractime

Displays the current time from the remote access
controller.

Synopsis
racadm getractime [-d]

Description
With no options, the getractime subcommand displays the time in a
common readable format.
With the -d option, getractime displays the time in the format,
yyyymmddhhmmss.mmmmmms, which is the same format returned by the
UNIX® date command.

Output
The getractime subcommand displays the output on one line.

Sample Output
racadm getractime
Thu Dec

8 20:15:26 2005

racadm getractime -d
20071208201542.000000
310

RACADM Subcommand Overview

Supported Interfaces
•

Local RACADM

setniccfg
Table A-11 describes the setniccfg subcommand.
Table A-11.

setniccfg

Subcommand

Definition

setniccfg

Sets the IP configuration for the controller.

Synopsis
racadm setniccfg -d
racadm setniccfg -s [  ]
racadm setniccfg -o [  ]

Description
The setniccfg subcommand sets the iDRAC6 IP address.
•

The -d option enables DHCP for the NIC (default is DHCP enabled).

•

The -s option enables static IP settings. The IP address, netmask, and
gateway can be specified. Otherwise, the existing static settings are used.
, , and  must be entered as dotseparated strings.
racadm setniccfg -s 192.168.0.120 255.255.255.0
192.168.0.1

•

The -o option disables the NIC completely. , ,
and  must be entered as dot-separated strings.
racadm setniccfg -o 192.168.0.120 255.255.255.0
192.168.0.1

Output
The setniccfg subcommand displays an appropriate error message if the
operation is not successful. If successful, a message is displayed.

RACADM Subcommand Overview

311

Supported Interfaces
•

Local RACADM

getniccfg
Table A-12 describes the getniccfg subcommand.
Table A-12. getniccfg
Subcommand

Definition

getniccfg

Displays the current IP configuration for iDRAC6.

Synopsis
racadm getniccfg

Description
The getniccfg subcommand displays the current NIC settings.

Sample Output
The getniccfg subcommand will display an appropriate error message if the
operation is not successful. Otherwise, on success, the output is displayed in
the following format:
NIC Enabled

= 1

DHCP Enabled

= 1

IP Address

= 192.168.0.1

Subnet Mask

= 255.255.255.0

Gateway

= 192.168.0.1

Supported Interfaces
•

312

Local RACADM

RACADM Subcommand Overview

getsvctag
Table A-13 describes the getsvctag subcommand.
Table A-13.

getsvctag

Subcommand

Definition

getsvctag

Displays a service tag.

Synopsis
racadm getsvctag

Description
The getsvctag subcommand displays the service tag of the host system.

Example
Enter getsvctag at the command prompt. The output is displayed as follows:
Y76TP0G
The command returns 0 on success and nonzero on errors.

Supported Interfaces
•

Local RACADM

racreset
Table A-14 describes the racreset subcommand.
Table A-14.

racreset

Subcommand

Definition

racreset

Resets iDRAC6.

NOTE: When you issue a racreset subcommand, iDRAC6 may require up to one
minute to return to a usable state.

Synopsis
racadm racreset

RACADM Subcommand Overview

313

Description
The racreset subcommand issues a reset to iDRAC6. The reset event is
written into the iDRAC6 log.

Examples
•

racadm racreset
Start the iDRAC6 soft-reset sequence.

Supported Interfaces
•

Local RACADM

racresetcfg
Table A-15 describes the racresetcfg subcommand.
Table A-15. racresetcfg
Subcommand

Definition

racresetcfg

Resets the entire RAC configuration to factory default values.

Synopsis
racadm racresetcfg

Supported Interfaces
•

Local RACADM

Description
The racresetcfg command removes all user-configured database property
entries. The database has default properties for all entries that are used to
restore iDRAC6 back to the default settings.
NOTE: This command deletes your current iDRAC6 configuration and resets
iDRAC6 configuration to the default settings. After reset, the default name and
password are root and calvin, respectively, and the IP address is 192.168.0.120 plus
the number of the slot the server inhabits in the chassis.

314

RACADM Subcommand Overview

serveraction
Table A-16 describes the serveraction subcommand.
Table A-16.

serveraction

Subcommand

Definition

serveraction

Executes a managed server reset or power-on/off/cycle.

Synopsis
racadm serveraction 

Description
The serveraction subcommand enables users to perform power management
operations on the host system. Table A-17 describes the serveraction power
control options.
Table A-17.

serveraction Subcommand Options

String

Definition



Specifies the action. The  string options are:
• powerdown — Powers down the managed server.
• powerup — Powers up the managed server.
• powercycle — Issues a power-cycle operation on the managed server.
This action is similar to pressing the power button on the system’s
front panel to power down and then power up the system.
• powerstatus — Displays the current power status of the server (ON,
or OFF).
• hardreset — Performs a reset (reboot) operation on the managed server.

Output
The serveraction subcommand displays an error message if the requested
operation could not be performed, or a success message if the operation
completed successfully.

RACADM Subcommand Overview

315

Supported Interfaces
•

Local RACADM

getraclog
Table A-18 describes the racadm getraclog command.
Table A-18. getraclog
Command

Definition

getraclog -i

Displays the number of entries in the iDRAC6 log.

getraclog

Displays the iDRAC6 log entries.

Synopsis
racadm getraclog -i
racadm getraclog [-A] [-o] [-c count] [-s startrecord] [-m]

Description
The getraclog -i command displays the number of entries in the iDRAC6 log.
NOTE: If no options are provided, the entire log is displayed.
The following options allow the getraclog command to read entries:
Table A-19. getraclog Subcommand Options
Option

Description

-A

Displays the output with no headers or labels.

-c

Provides the maximum count of entries to be returned.

-m

Displays one screen of information at a time and prompts the user to
continue (similar to the UNIX more command).

-o

Displays the output in a single line.

-s

Specifies the starting record used for the display.

316

RACADM Subcommand Overview

Output
The default output display shows the record number, time stamp, source, and
description. The timestamp begins at midnight, January 1 and increases until
the managed server boots. After the managed server boots, the managed
server’s system time is used for the timestamp.

Sample Output
Record:
Date/Time:
Source:
Description:

1
Dec 8 08:10:11
login[433]
root login from 143.166.157.103

Supported Interfaces
•

Local RACADM

clrraclog
Synopsis
racadm clrraclog

Description
The clrraclog subcommand removes all existing records from the iDRAC6
log. A new single record is created to record the date and time when the
log was cleared.

getsel
Table A-20 describes the getsel command.
Table A-20.

getsel

Command

Definition

getsel -i

Displays the number of entries in the System
Event Log.

getsel

Displays SEL entries.

RACADM Subcommand Overview

317

Synopsis
racadm getsel -i
racadm getsel [-E] [-R] [-A] [-o] [-c count] [-s
count] [-m]

Description
The getsel -i command displays the number of entries in the SEL.
The following getsel options (without the -i option) are used to read entries.
NOTE: If no arguments are specified, the entire log is displayed.
Table A-21. getsel Subcommand Options
Option

Description

-A

Specifies output with no display headers or labels.

-c

Provides the maximum count of entries to be returned.

-o

Displays the output in a single line.

-s

Specifies the starting record used for the display.

-E

Places the 16 bytes of raw SEL at the end of each line of output as a
sequence of hex values.

-R

Only the raw data is printed.

-m

Displays one screen at a time and prompts the user to continue (similar to
the UNIX more command).

Output
The default output display shows the record number, timestamp, severity, and
description.
For example:
Record:
1
Date/Time:
11/16/2005 22:40:43
Severity:
Ok
Description: System Board SEL: event log sensor for
System Board, log cleared was asserted

318

RACADM Subcommand Overview

Supported Interfaces
•

Local RACADM

clrsel
Synopsis
racadm clrsel

Description
The clrsel command removes all existing records from the System Event Log
(SEL).

Supported Interfaces
•

Local RACADM

gettracelog
Table A-22 describes the gettracelog subcommand.
Table A-22.

gettracelog

Command

Definition

gettracelog -i

Displays the number of entries in the iDRAC trace
log.

gettracelog

Displays the iDRAC trace log.

Synopsis
racadm gettracelog -i
racadm gettracelog [-A] [-o] [-c count] [-s
startrecord] [-m]

RACADM Subcommand Overview

319

Description
The gettracelog (without the -i option) command reads entries.
The following gettracelog entries are used to read entries:
Table A-23. gettracelog Subcommand options
Option

Description

-i

Displays the number of entries in the iDRAC trace log.

-m

Displays one screen at a time and prompts the user to continue
(similar to the UNIX more command).

-o

Displays the output in a single line.

-c

specifies the number of records to display.

-s

specifies the starting record to display.

-A

do not display headers or labels.

Output
The default output display shows the record number, timestamp, source, and
description. The timestamp begins at midnight, January 1 and increases until
the managed system boots. After the managed system boots, the managed
system’s system time is used for the timestamp.
For example:
Record:

1

Date/Time:

Dec

Source:

ssnmgrd[175]

8 08:21:30

Description: root from 143.166.157.103: session
timeout sid 0be0aef4

Supported Interfaces
•

320

Local RACADM

RACADM Subcommand Overview

sslcsrgen
Table A-24 describes the sslcsrgen subcommand.
Table A-24.

sslcsrgen

Subcommand

Description

sslcsrgen

Generates and downloads an SSL certificate signing
request (CSR) from the RAC.

Synopsis
racadm sslcsrgen [-g] [-f ]
racadm sslcsrgen -s

Description
The sslcsrgen subcommand can be used to generate a CSR and download the
file to the client’s local file system. The CSR can be used for creating a
custom SSL certificate that can be used for SSL transactions on the RAC.

Options
Table A-25 describes the sslcsrgen subcommand options.
Table A-25.

sslcsrgen Subcommand Options

Option

Description

-g

Generates a new CSR.

-s

Returns the status of a CSR generation process (generation in progress,
active, or none).

-f

Specifies the filename of the location, , where the CSR will
be downloaded.

NOTE: If the -f option is not specified, the filename defaults to sslcsr in your current
directory.
If no options are specified, a CSR is generated and downloaded to the local
file system as sslcsr by default. The -g option cannot be used with the -s
option, and the -f option can only be used with the -g option.

RACADM Subcommand Overview

321

The sslcsrgen -s subcommand returns one of the following status codes:
•

CSR was generated successfully.

•

CSR does not exist.

•

CSR generation in progress.
NOTE: Before a CSR can be generated, the CSR fields must be configured in the
RACADM cfgRacSecurity group. For example: racadm config -g
cfgRacSecurity -o cfgRacSecCsrCommonName MyCompany

Examples

racadm sslcsrgen -s
or
racadm sslcsrgen -g -f c:\csr\csrtest.txt

Supported Interfaces
•

Local RACADM

sslcertupload
Table A-26 describes the sslcertupload subcommand.
Table A-26. sslcertupload
Subcommand

Description

sslcertupload

Uploads a custom SSL server or CA certificate from
the client to iDRAC6.

Synopsis
racadm sslcertupload -t  [-f ]

322

RACADM Subcommand Overview

Options
Table A-27 describes the sslcertupload subcommand options.
Table A-27.

sslcertupload Subcommand Options

Option

Description

-t

Specifies the type of certificate to upload, either the CA certificate or
server certificate.
1 = server certificate
2 = CA certificate

-f

Specifies the file name of the certificate to be uploaded. If the file is not
specified, the sslcert file in the current directory is selected.

The sslcertupload command returns 0 when successful and returns a nonzero
number when unsuccessful.

Example
racadm sslcertupload -t 1 -f c:\cert\cert.txt

Supported Interfaces
•

Local RACADM

sslcertdownload
Table A-28 describes the sslcertdownload subcommand.
Table A-28.

sslcertdownload

Subcommand

Description

sslcertdownload

Downloads an SSL certificate from the RAC to the
client’s file system.

Synopsis
racadm sslcertdownload -t  [-f ]

RACADM Subcommand Overview

323

Options
Table A-29 describes the sslcertdownload subcommand options.
Table A-29. sslcertdownload Subcommand Options
Option

Description

-t

Specifies the type of certificate to download, either the Microsoft®
Active Directory® certificate or server certificate.
1 = server certificate
2 = Microsoft Active Directory certificate

-f

Specifies the file name of the certificate to be downloaded. If the -f
option or the filename is not specified, the sslcert file in the current
directory is selected.

The sslcertdownload command returns 0 when successful and returns a
nonzero number when unsuccessful.

Example
racadm sslcertdownload -t 1 -f c:\cert\cert.txt

Supported Interfaces
•

Local RACADM

sslcertview
Table A-30 describes the sslcertview subcommand.
Table A-30. sslcertview
Subcommand

Description

sslcertview

Displays the SSL server or CA certificate that exists
on iDRAC6.

Synopsis
racadm sslcertview -t  [-A]

324

RACADM Subcommand Overview

Options
Table A-31 describes the sslcertview subcommand options.
Table A-31.

sslcertview Subcommand Options

Option

Description

-t

Specifies the type of certificate to view, either the Microsoft Active
Directory certificate or server certificate.
1 = server certificate
2 = Microsoft Active Directory certificate

-A

Prevents printing headers/labels.

Output Example
racadm sslcertview -t 1
Serial Number

: 00

Subject Information:
Country Code (CC)
State (S)
Locality (L)
Organization (O)
Organizational Unit (OU)
Common Name (CN)

:
:
:
:
:
:

US
Texas
Round Rock
Dell Inc.
Remote Access Group
iDRAC default certificate

Issuer Information:
Country Code (CC)
State (S)
Locality (L)
Organization (O)
Organizational Unit (OU)
Common Name (CN)

:
:
:
:
:
:

US
Texas
Round Rock
Dell Inc.
Remote Access Group
iDRAC default certificate

RACADM Subcommand Overview

325

Valid From
Valid To

: Jul
: Jul

8 16:21:56 2005 GMT
7 16:21:56 2010 GMT

racadm sslcertview -t 1 -A
00
US
Texas
Round Rock
Dell Inc.
Remote Access Group
iDRAC default certificate
US
Texas
Round Rock
Dell Inc.
Remote Access Group
iDRAC default certificate
Jul 8 16:21:56 2005 GMT
Jul 7 16:21:56 2010 GMT

Supported Interfaces
•

Local RACADM

testemail
Table A-32 describes the testemail subcommand.
Table A-32. testemail configuration
Subcommand

Description

testemail

Tests the iDRAC6 e-mail alerting feature.

Synopsis
racadm testemail -i 

326

RACADM Subcommand Overview

Description
Sends a test e-mail from iDRAC6 to a specified destination.
Prior to executing the testemail command, ensure that the specified index in
the RACADM cfgEmailAlert group is enabled and configured properly.
Table A-33 provides an example of commands for the cfgEmailAlert group.
Table A-33.

testemail Configuration

Action

Command

Enable the alert

racadm config -g cfgEmailAlert -o
cfgEmailAlertEnable
-i 1 1

Set the destination
e-mail address

racadm config -g cfgEmailAlert -o
cfgEmailAlertAddress -i 1
user1@mycompany.com

Set the custom message racadm config -g cfgEmailAlert -o
that is sent to the
cfgEmailAlertCustomMsg -i 1 "This is a
destination e-mail
test!"
address
Ensure the SNMP IP
address is configured
properly

racadm config -g cfgRemoteHosts -o
cfgRhostsSmtpServerIpAddr -i
192.168.0.152

View the current e-mail
alert settings

racadm getconfig -g cfgEmailAlert -i

where  is a number from 1 to 4

Options
Table A-34 describes the testemail subcommand options.
Table A-34.

testemail Subcommand Option

Option

Description

-i

Specifies the index of the e-mail alert to
test.

Output
None.
RACADM Subcommand Overview

327

Supported Interfaces
•

Local RACADM

testtrap
Table A-35 describes the testtrap subcommand.
Table A-35. testtrap
Subcommand

Description

testtrap

Tests the iDRAC6 SNMP trap-alerting feature.

Synopsis
racadm testtrap -i 

Description
The testtrap subcommand tests the iDRAC6 SNMP trap-alerting feature by
sending a test trap from iDRAC6 to a specified destination trap listener on
the network.
Before you execute the testtrap subcommand, ensure that the specified index
in the RACADM cfgIpmiPet group is configured properly.
Table A-36 provides a list and associated commands for the cfgIpmiPet
group.
Table A-36. cfg e-mail Alert Commands
Action

Command

Enable the alert

racadm config -g cfgIpmiPet -o
cfgIpmiPetAlertEnable -i 1 1

Set the destination
e-mail IP address

racadm config -g cfgIpmiPet -o
cfgIpmiPetAlertDestIpAddr -i 1
192.168.0.110

View the current test trap racadm getconfig -g cfgIpmiPet -i
settings

where  is a number from 1 to 4

328

RACADM Subcommand Overview

Input

Table A-37 describes the testtrap subcommand options.
Table A-37.

testtrap Subcommand Options

Option

Description

-i

Specifies the index of the trap configuration to use for the test Valid
values are from 1 to 4.

Supported Interfaces
•

Local RACADM

vmdisconnect
Synopsis
racadm vmdisconnect

Description
The vmdisconnect subcommand disconnects any virtual media connections.

clrasrscreen
Synopsis
racadm clrasrscreen

Description
Clear the last crash (ASR) screen

localconredirdisable
Synopsis
racadm localconredirdisable [0, 1]

RACADM Subcommand Overview

329

Description
Perform local kVM disable from the local system

Legal Values
0 = Enable
1 = Disable

vmkey
Synopsis
racadm vmkey [ reset ]

Description
The vmkey subcommand resets the virtual media key to the default size of
256MB.

Legal Values
reset = Resets the key to the default size (256 MB)

version
Synopsis
racadm version

Description
Display the RACADM version

330

RACADM Subcommand Overview

iDRAC6 Enterprise Property
Database Group and Object
Definitions
The iDRAC6 property database contains the configuration information for
iDRAC6. Data is organized by associated object, and objects are organized by
object group. The IDs for the groups and objects that the property database
supports are listed in this section.
Use the group and object IDs with the RACADM utility to configure
iDRAC6. The following sections describe each object and indicate whether
the object is readable, writable, or both.
All string values are limited to displayable ASCII characters, except where
otherwise noted.

Displayable Characters
Displayable characters include the following set:
abcdefghijklmnopqrstuvwxwz
ABCDEFGHIJKLMNOPQRSTUVWXYZ
0123456789~`!@#$%^&*()_+-={}[]|\:";'<>,.?/

idRacInfo
This group contains display parameters to provide information about the
specifics of the iDRAC6 being queried.
One instance of the group is allowed. The following subsections describe the
objects in this group.

iDRAC6 Enterprise Property Database Group and Object Definitions

331

idRacProductInfo (Read Only)
Legal Values

String of up to 63 ASCII characters
Default

Integrated Dell Remote Access Controller
Description

A text string that identifies the product

idRacDescriptionInfo (Read Only)
Legal Values

String of up to 255 ASCII characters
Default

This system component provides a complete set of remote management
functions for Dell PowerEdge servers.
Description

A text description of the RAC type

idRacVersionInfo (Read Only)
Legal Values

String of up to 63 ASCII characters
Default

1
Description

A string containing the current product firmware version

332

iDRAC6 Enterprise Property Database Group and Object Definitions

idRacBuildInfo (Read Only)
Legal Values

String of up to 16 ASCII characters
Default

The current RAC firmware build version. For example, 05.12.06.
Description

A string containing the current product build version

idRacName (Read Only)
Legal Values

String of up to 15 ASCII characters
Default

iDRAC
Description

A user assigned name to identify this controller

idRacType (Read Only)
Legal Values

Product ID
Default

8
Description

Identifies the remote access controller type as iDRAC6

iDRAC6 Enterprise Property Database Group and Object Definitions

333

cfgOobSnmp
This group contains parameters to configure the SNMP agent and trap
capabilities of the iDRAC.
One instance of the group is allowed. The following subsections describe the
objects in this group.

cfgOobSnmpAgentCommunity (Read/Write)
Legal Values

String. Maximum length = 31
Default

public
Description

Specifies the SNMP Community Name used for SNMP traps

cfgOobSnmpAgentEnable (Read/Write)
Legal Values

1 (TRUE)
0 (FALSE)
Default

0
Description

Enables or disables the SNMP agent in the RAC

334

iDRAC6 Enterprise Property Database Group and Object Definitions

cfgLanNetworking
This group contains parameters to configure the iDRAC6 NIC.
One instance of the group is allowed. All objects in this group will require the
iDRAC6 NIC to be reset, which may cause a brief loss in connectivity. Objects
that change the iDRAC6 NIC IP address settings will close all active user
sessions and require users to reconnect using the updated IP address settings.

cfgDNSDomainNameFromDHCP (Read/Write)
Legal Values

1 (TRUE)
0 (FALSE)
Default

0
Description

Specifies that the iDRAC6 DNS domain name should be assigned from the
network DHCP server

cfgDNSDomainName (Read/Write)
Legal Values

String of up to 254 ASCII characters. At least one of the characters must be
alphabetic. Characters are restricted to alphanumeric, hyphens and periods.
NOTE: Microsoft® Active Directory® only supports Fully Qualified Domain Names
(FQDN) of 64 bytes or fewer.

Default

(blank)
Description

The DNS domain name. This parameter is only valid if
cfgDNSDomainNameFromDHCP is set to 0 (FALSE).

iDRAC6 Enterprise Property Database Group and Object Definitions

335

cfgDNSRacName (Read/Write)
Legal Values

String of up to 63 ASCII characters. At least one character must be
alphabetic.
NOTE: Some DNS servers only register names of 31 characters or fewer.
Default

idrac-service tag
Description

Displays the RAC name, which is idrac-service tag by default. This parameter
is only valid if cfgDNSRegisterRac is set to 1 (TRUE).

cfgDNSRegisterRac (Read/Write)
Legal Values

1 (TRUE)
0 (FALSE)
Default

0
Description

Registers the iDRAC6 name on the DNS server

cfgDNSServersFromDHCP (Read/Write)
Legal Values

1 (TRUE)
0 (FALSE)
Default

0

336

iDRAC6 Enterprise Property Database Group and Object Definitions

Description

Specifies that the DNS server IP addresses should be assigned from the
DHCP server on the network

cfgDNSServer1 (Read/Write)
Legal Values

A string representing a valid IP address. For example: 192.168.0.20.
Default

0.0.0.0
Description

Specifies the IP address for DNS server 1. This property is only valid if
cfgDNSServersFromDHCP is set to 0 (FALSE).
NOTE: cfgDNSServer1 and cfgDNSServer2 may be set to identical values while
swapping addresses.

cfgDNSServer2 (Read/Write)
Legal Values

A string representing a valid IP address. For example: 192.168.0.20.
Default

0.0.0.0
Description

Retrieves the IP address for DNS server 2. This parameter is only valid if
cfgDNSServersFromDHCP is set to 0 (FALSE).
NOTE: cfgDNSServer1 and cfgDNSServer2 may be set to identical values while
swapping addresses.

iDRAC6 Enterprise Property Database Group and Object Definitions

337

cfgNicEnable (Read/Write)
Legal Values

1 (TRUE)
0 (FALSE)
Default

0
Description

Enables or disables the iDRAC6 network interface controller. If the NIC is
disabled, the remote network interfaces to iDRAC6 will no longer be
accessible, and iDRAC6 will only be available through the local RACADM
interface.

cfgNicIpAddress (Read/Write)
NOTE: This parameter is only configurable if the cfgNicUseDhcp parameter is set
to 0 (FALSE).
Legal Values

A string representing a valid IP address. For example: 192.168.0.20.
Default

192.168.0.n
where n is 120 plus the server slot number
Description

Specifies the static IP address to assign to the RAC. This property is only valid
if cfgNicUseDhcp is set to 0 (FALSE).

cfgNicNetmask (Read/Write)
NOTE: This parameter is only configurable if the cfgNicUseDhcp parameter is set
to 0 (FALSE).

338

iDRAC6 Enterprise Property Database Group and Object Definitions

Legal Values

A string representing a valid subnet mask. For example: 255.255.255.0.
Default

255.255.255.0
Description

The subnet mask used for static assignment of the iDRAC6 IP address.
This property is only valid if cfgNicUseDhcp is set to 0 (FALSE).

cfgNicGateway (Read/Write)
NOTE: This parameter is only configurable if the cfgNicUseDhcp parameter is set
to 0 (FALSE).
Legal Values

A string representing a valid gateway IP address. For example: 192.168.0.1.
Default

192.168.0.1
Description

The gateway IP address used for static assignment of the RAC IP address.
This property is only valid if cfgNicUseDhcp is set to 0 (FALSE).

cfgNicUseDhcp (Read/Write)
Legal Values

1 (TRUE)
0 (FALSE)
Default

0

iDRAC6 Enterprise Property Database Group and Object Definitions

339

Description

Specifies whether DHCP is used to assign the iDRAC6 IP address. If this
property is set to 1 (TRUE), then the iDRAC6 IP address, subnet mask, and
gateway are assigned from the DHCP server on the network. If this property is
set to 0 (FALSE), the static IP address, subnet mask, and gateway is assigned
from the cfgNicIpAddress, cfgNicNetmask, and cfgNicGateway properties.

cfgNicMacAddress (Read Only)
Legal Values

A string representing the RAC NIC MAC address
Default

The current MAC address of the iDRAC6 NIC. For example,
00:12:67:52:51:A3.
Description

The iDRAC6 NIC MAC address

cfgUserAdmin
This group provides configuration information about the users who are
allowed to access the RAC through the available remote interfaces.
Up to 16 instances of the user group are allowed. Each instance represents the
configuration for an individual user.

cfgUserAdminIndex (Read Only)
Legal Values

This parameter is populated based on the existing instances
Default

1 – 16
Description

The unique index of a user
340

iDRAC6 Enterprise Property Database Group and Object Definitions

cfgUserAdminIpmiLanPrivilege (Read/Write)
Legal Values

2 (User)
3 (Operator)
4 (Administrator)
15 (No access)
Default

4 (User 2)
15 (All others)
Description

The maximum privilege on the IPMI LAN channel

cfgUserAdminPrivilege (Read/Write)
Legal Values

0x00000000 to 0x000001ff, and 0x0
Default

0x00000000
Description

This property specifies the role-based authority privileges allowed for the user.
The value is represented as a bit mask that allows for any combination of
privilege values. Table B-1 describes the user privilege bit values that can be
combined to create bit masks.
Table B-1.

Bit Masks for User Privileges

User Privilege

Privilege Bit Mask

Login to iDRAC6

0x0000001

Configure iDRAC6

0x0000002

Configure Users

0x0000004

iDRAC6 Enterprise Property Database Group and Object Definitions

341

Table B-1.

Bit Masks for User Privileges (continued)

User Privilege

Privilege Bit Mask

Clear Logs

0x0000008

Execute Server Control Commands

0x0000010

Access Console Redirection

0x0000020

Access Virtual Media

0x0000040

Test Alerts

0x0000080

Execute Debug Commands

0x0000100

Examples

Table B-2 provides sample privilege bit masks for users with one or
more privileges.
Table B-2.

Sample Bit Masks for User Privileges

User Privilege(s)

Privilege Bit Mask

The user is not allowed to access
iDRAC6.

0x00000000

The user may only login to
0x00000001
iDRAC6 and view iDRAC6 and
server configuration information.
The user may login to iDRAC6
and change configuration.

0x00000001 + 0x00000002 = 0x00000003

The user may login to RAC,
access virtual media, and access
console redirection.

0x00000001 + 0x00000040 + 0x00000080 =
0x000000C1

cfgUserAdminUserName (Read/Write)
Legal Values

String. Maximum length = 16
Default

(blank)

342

iDRAC6 Enterprise Property Database Group and Object Definitions

Description

The name of the user for this index. The user index is created by writing a
string into this name field if the index is empty. Writing a string of double
quotes ("") deletes the user at that index. You cannot change the name.
You must delete and then recreate the name. The string must not contain /
(forward slash), \ (backslash), . (period), @ (at symbol) or quotation marks.
NOTE: This property value must be unique among user names.

cfgUserAdminPassword (Write Only)
Legal Values

A string of up to 20 ASCII characters
Default

(blank)
Description

The password for this user. User passwords are encrypted and cannot be seen
or displayed after the property is written.

cfgUserAdminEnable
Legal Values

1 (TRUE)
0 (FALSE)
Default

0
Description

Enables or disables an individual user

iDRAC6 Enterprise Property Database Group and Object Definitions

343

cfgUserAdminSolEnable
Legal Values

1 (TRUE)
0 (FALSE)
Default

0
Description

Enables or disables Serial Over LAN (SOL) user access

cfgEmailAlert
This group contains parameters to configure the RAC e-mail alerting
capabilities.
The following subsections describe the objects in this group. Up to four
instances of this group are allowed.

cfgEmailAlertIndex (Read Only)
Legal Values

1–4
Default

This parameter is populated based on the existing instances.
Description

The unique index of an alert instance

cfgEmailAlertEnable (Read/Write)
Legal Values

1 (TRUE)
0 (FALSE)
344

iDRAC6 Enterprise Property Database Group and Object Definitions

Default

0
Description

Specifies the destination email address for email alerts. For example,
user1@company.com.

cfgEmailAlertAddress
Legal Values

E-mail address format, with a maximum length of 64 ASCII characters
Default

(blank)
Description

The e-mail address of the alert source

cfgEmailAlertCustomMsg
Legal Values

A string of up to 32 characters
Default

(blank)
Description

Specifies a custom message that is sent with the alert

cfgSessionManagement
This group contains parameters to configure the number of sessions that can
connect to iDRAC6.
One instance of the group is allowed. The following subsections describe the
objects in this group.

iDRAC6 Enterprise Property Database Group and Object Definitions

345

cfgSsnMgtConsRedirMaxSessions (Read/Write)
Legal Values

1–4
Default

4
Description

Specifies the maximum number of console redirection sessions allowed on
iDRAC6

cfgSsnMgtWebserverTimeout (Read/Write)
Legal Values

60 – 10800
Default

1800
Description

Defines the Web server time-out. This property sets the amount of time in
seconds that a connection is allowed to remain idle (there is no user input).
The session is cancelled if the time limit set by this property is reached.
Changes to this setting do not affect the current session; you must log out
and log in again to make the new settings effective.
An expired Web server session logs out the current session.

cfgSsnMgtSshIdleTimeout (Read/Write)
Legal Values

0 (No time-out)
60 – 10800

346

iDRAC6 Enterprise Property Database Group and Object Definitions

Default

1800
Description

Defines the secure shell idle time-out. This property sets the amount of time
in seconds that a connection is allowed to remain idle (there is no user input).
The session is cancelled if the time limit set by this property is reached.
Changes to this setting do not affect the current session; you must log out
and log in again to make the new settings effective.
An expired secure shell session displays the following error message only after
you press :
Warning: Session no longer valid, may have timed out
After the message appears, the system returns you to the shell that generated
the Secure Shell session.

cfgSsnMgtTelnetIdleTimeout (Read/Write)
Legal Values

0 (No timeout)
60 – 10800
Default

1800
Description

Defines the telnet idle time-out. This property sets the amount of time in
seconds that a connection is allowed to remain idle (there is no user input).
The session is cancelled if the time limit set by this property is reached.
Changes to this setting do not affect the current session (you must log out
and log in again to make the new settings effective).
An expired telnet session displays the following error message only after you
press :
Warning: Session no longer valid, may have timed out
After the message appears, the system returns you to the shell that generated
the telnet session.
iDRAC6 Enterprise Property Database Group and Object Definitions

347

cfgSerial
This group contains configuration parameters for iDRAC6 services.
One instance of the group is allowed. The following subsections describe the
objects in this group.

cfgSerialSshEnable (Read/Write)
Legal Values

1 (TRUE)
0 (FALSE)
Default

1
Description

Enables or disables the secure shell (SSH) interface on iDRAC6

cfgSerialTelnetEnable (Read/Write)
Legal Values

1 (TRUE)
0 (FALSE)
Default

0
Description

Enables or disables the telnet console interface on iDRAC6

cfgRemoteHosts
This group provides properties that allow configuration of the SMTP server
for e-mail alerts.

348

iDRAC6 Enterprise Property Database Group and Object Definitions

cfgRhostsSmtpServerIpAddr (Read/Write)
Legal Values

A string representing a valid SMTP server IP address. For example:
192.168.0.56.
Default

0.0.0.0
Description

The IP address of the network SMTP server. The SMTP server transmits
e-mail alerts from the RAC if the alerts are configured and enabled.

cfgUserDomain
This group is used to configure the Active Directory user domain names.
A maximum of 40 domain names can be configured at any given time.

cfgUserDomainIndex (Read Only)
Legal Values

1 – 40
Default


Description

Represents a specific domain

cfgUserDomainName (Read/Write)
Legal Values

A string of up to 255 characters
Default

(blank)
iDRAC6 Enterprise Property Database Group and Object Definitions

349

Description

Specifies the Active Directory user domain name

cfgServerPower
This group provides several power management features.

cfgServerPowerStatus (Read Only)
Legal Values

1 = TRUE
0 = FALSE
Default

0
Description

Represents the server power state, either ON or OFF

cfgServerPowerServerAllocation (Read Only)
Legal Values

String of up to 32 characters
Default

(blank)
Description

Represents the available power supply for server usage

cfgServerPowerActualPowerConsumption (Read Only)
Legal Values

String of up to 32 characters

350

iDRAC6 Enterprise Property Database Group and Object Definitions

Default

(blank)
Description

Represents the power consumed by the server at the current time

cfgServerPowerPeakPowerConsumption (Read Only)
Legal Values

String of up to 32 characters
Default

(blank)
Description

Represents the maximum power consumed by the server until the current
time

cfgServerPowerPeakPowerTimestamp (Read Only)
Legal Values

String of up to 32 characters
Default

(blank)
Description

Time when the maximum power consumption was recorded

cfgServerPowerConsumptionClear (Write Only)
Legal Values

0, 1

iDRAC6 Enterprise Property Database Group and Object Definitions

351

Default

0
Description

Resets the cfgServerPeakPowerConsumption property to 0 and the
cfgServerPeakPowerConsumptionTimestamp property to the current
iDRAC6 time

cfgServerPowerCapWatts (Read Only)
Legal Values

String of up to 32 characters
Default

(blank)
Description

Represents the server power threshold in Watts

cfgServerPowerCapBtuhr (Read Only)
Legal Values

String of up to 32 characters
Default

(blank)
Description

Represents the server power threshold in BTU/hr

cfgServerPowerCapPercent (Read Only)
Legal Values

String of up to 32 characters

352

iDRAC6 Enterprise Property Database Group and Object Definitions

Default

(blank)
Description

Represents the server power threshold in percentage

cfgRacTuning
This group is used to configure various iDRAC6 configuration properties,
such as valid ports and security port restrictions.

cfgRacTuneHttpPort (Read/Write)
Legal Values

10 – 65535
Default

80
Description

Specifies the port number to use for HTTP network communication with
the RAC

cfgRacTuneHttpsPort (Read/Write)
Legal Values

10 – 65535
Default

443
Description

Specifies the port number to use for HTTPS network communication with
iDRAC6

iDRAC6 Enterprise Property Database Group and Object Definitions

353

cfgRacTuneIpRangeEnable
Legal Values

1 (TRUE)
0 (FALSE)
Default

0
Description

Enables or disables the IP Address Range validation feature of iDRAC6

cfgRacTuneIpRangeAddr
Legal Values

An IP address-formatted string. For example, 192.168.0.44.
Default

192.168.1.1
Description

Specifies the acceptable IP address bit pattern in positions determined by the
1's in the range mask property (cfgRacTuneIpRangeMask)

cfgRacTuneIpRangeMask
Legal Values

Standard IP mask values with left-justified bits
Default

255.255.255.0
Description

An IP address-formatted string. For example, 255.255.255.0.

354

iDRAC6 Enterprise Property Database Group and Object Definitions

cfgRacTuneIpBlkEnable
Legal Values

1 (TRUE)
0 (FALSE)
Default

0
Description

Enables or disables the IP address blocking feature of the RAC

cfgRacTuneIpBlkFailCount
Legal Values

2 – 16
Default

5
Description

The maximum number of login failures to occur within the window
(cfgRacTuneIpBlkFailWindow) before login attempts from the IP address
are rejected

cfgRacTuneIpBlkFailWindow
Legal Values

10 – 65535
Default

60

iDRAC6 Enterprise Property Database Group and Object Definitions

355

Description

Defines the time span in seconds that the failed attempts are counted.
When failure attempts age beyond this limit, they are dropped from the count.

cfgRacTuneIpBlkPenaltyTime
Legal Values

10 – 65535
Default

300
Description

Defines the time span in seconds that session requests from an IP address
with excessive failures are rejected

cfgRacTuneSshPort (Read/Write)
Legal Values

1 – 65535
Default

22
Description

Specifies the port number used for the iDRAC6 SSH interface

cfgRacTuneConRedirEnable (Read/Write)
Legal Values

1 (TRUE)
0 (FALSE)
Default

1

356

iDRAC6 Enterprise Property Database Group and Object Definitions

Description

Enables or disables console redirection

cfgRacTuneTelnetPort (Read/Write)
Legal Values

1 – 65535
Default

23
Description

Specifies the port number used for the iDRAC6 telnet interface

cfgRacTuneConRedirEncryptEnable (Read/Write)
Legal Values

1 (TRUE)
0 (FALSE)
Default

1
Description

Encrypts the video in a console redirection session

cfgRacTuneConRedirPort (Read/Write)
Legal Values

1 – 65535
Default

5900

iDRAC6 Enterprise Property Database Group and Object Definitions

357

Description

Specifies the port to be used for keyboard and mouse traffic during console
redirection activity with iDRAC6

cfgRacTuneConRedirVideoPort (Read/Write)
Legal Values

1 – 65535
Default

5901
Description

Specifies the port to be used for video traffic during console redirection
activity with iDRAC6
NOTE: This object requires an iDRAC6 reset before it becomes active.

cfgRacTuneAsrEnable (Read/Write)
Legal Values

0 (FALSE)
1 (TRUE)
Default

1
Description

Enables or disables the iDRAC6 last-crash-screen capture feature
NOTE: This object requires an iDRAC6 reset before it becomes active.

cfgRacTuneWebserverEnable (Read/Write)
Legal Values

0 (FALSE)
1 (TRUE)
358

iDRAC6 Enterprise Property Database Group and Object Definitions

Default

1
Description

Enables and disables the iDRAC6 Web server. If this property is disabled,
iDRAC6 will not be accessible using client Web browsers. This property has
no effect on the telnet/SSH or local RACADM interfaces.

cfgRacTuneLocalServerVideo (Read/Write)
Legal Values

1 (Enables)
0 (Disables)
Default

1
Description

Enables (switches ON) or disables (switches OFF) the local server video

cfgRacTuneLocalConfigDisable (Read/Write)
Legal Values

0 (Enables)
1 (Disables)
Default

0
Description

Disables write access to iDRAC6 configuration data. The default is for access
to be enabled.
NOTE: Access can be disabled using the Local RACADM or the iDRAC6 Web
interface; however, once disabled, access can be re-enabled only through the
iDRAC6 Web interface.

iDRAC6 Enterprise Property Database Group and Object Definitions

359

ifcRacManagedNodeOs
This group contains properties that describe the Managed Server
operating system.
One instance of the group is allowed. The following subsections describe the
objects in this group.

ifcRacMnOsHostname (Read Only)
Legal Values

A string of up to 255 characters
Default

(blank)
Description

The host name of the managed server

ifcRacMnOsOsName (Read Only)
Legal Values

A string of up to 255 characters
Default

(blank)
Description

The operating system name of the managed server

cfgRacSecurity
This group is used to configure settings related to the iDRAC6 SSL certificate
signing request (CSR) feature. The properties in this group must be
configured before generating a CSR from iDRAC6.
See the RACADM sslcsrgen subcommand details for more information on
generating certificate signing requests.
360

iDRAC6 Enterprise Property Database Group and Object Definitions

cfgSecCsrCommonName (Read/Write)
Legal Values

A string of up to 254 characters
Default
Description

Specifies the CSR Common Name (CN)

cfgSecCsrOrganizationName (Read/Write)
Legal Values

A string of up to 254 characters
Default

(blank)
Description

Specifies the CSR Organization Name (O)

cfgSecCsrOrganizationUnit (Read/Write)
Legal Values

A string of up to 254 characters
Default

(blank)
Description

Specifies the CSR Organization Unit (OU)

cfgSecCsrLocalityName (Read/Write)
Legal Values

A string of up to 254 characters
iDRAC6 Enterprise Property Database Group and Object Definitions

361

Default

(blank)
Description

Specifies the CSR Locality (L)

cfgSecCsrStateName (Read/Write)
Legal Values

A string of up to 254 characters
Default

(blank)
Description

Specifies the CSR State Name (S)

cfgSecCsrCountryCode (Read/Write)
Legal Values

A two-character string
Default

(blank)
Description

Specifies the CSR Country Code (CC)

cfgSecCsrEmailAddr (Read/Write)
Legal Values

A string of up to 254 characters
Default

(blank)

362

iDRAC6 Enterprise Property Database Group and Object Definitions

Description

Specifies the CSR Email Address.

cfgSecCsrKeySize (Read/Write)
Legal Values

512
1024
2048
Default

1024
Description

Specifies the SSL asymmetric key size for the CSR

cfgRacVirtual
This group contains parameters to configure the iDRAC6 virtual media
feature. One instance of the group is allowed. The following subsections
describe the objects in this group.

cfgVirMediaAttached (Read/Write)
Legal Values

0 = Detach
1 = Attach
2 = Auto Attach
Default

0

iDRAC6 Enterprise Property Database Group and Object Definitions

363

Description

This object is used to attach virtual devices to the system via the USB bus.
When the devices are attached the server will recognize valid USB mass
storage devices attached to the system. This is equivalent to attaching a local
USB CDROM/floppy drive to a USB port on the system. When the devices
are attached you then can connect to the virtual devices remotely using the
iDRAC6 Web interface or the CLI. Setting this object to 0 will cause the
devices to detach from the USB bus.
NOTE: You must restart your system to enable all changes.

cfgVirMediaBootOnce (Read/Write)
Legal Values

1 (Enabled)
0 (Disabled)
Default

0
Description

Enables or disables the virtual media boot-once feature of iDRAC6. If this
property is enabled when the host server is rebooted, this feature will attempt
to boot from the virtual media devices—if the appropriate media is installed
in the device.

cfgVirMediaKeyEnable (Read/Write)
Legal Values

1 (TRUE)
0 (FALSE)
Default

0

364

iDRAC6 Enterprise Property Database Group and Object Definitions

Description

Enables or disables the virtual media key feature of the iDRAC

cfgFloppyEmulation (Read/Write)
Legal Values

1 (TRUE)
0 (FALSE)
Default

0
Description

When set to 0, the virtual floppy drive is recognized as a removable disk by
Windows operating systems. Windows operating systems will assign a drive
letter that is C: or higher during enumeration. When set to 1, the Virtual
Floppy drive will be seen as a floppy drive by Windows operating systems.
Windows operating systems will assign a drive letter of A: or B:.

cfgActiveDirectory
This group contains parameters to configure the iDRAC6 Active Directory
feature.

cfgADRacDomain (Read/Write)
Legal Values

Any printable text string with no white space. Length is limited to
254 characters.
Default

(blank)
Description

Active Directory Domain in which the DRAC resides

iDRAC6 Enterprise Property Database Group and Object Definitions

365

cfgADRacName (Read/Write)
Legal Values

Any printable text string with no white space. Length is limited to
254 characters.
Default

(blank)
Description

Name of iDRAC6 as recorded in the Active Directory forest

cfgADEnable (Read/Write)
Legal Values

1 (TRUE)
0 (FALSE)
Default

0
Description

Enables or disables Active Directory user authentication on iDRAC6. If this
property is disabled, local iDRAC6 authentication is used for user logins instead.

cfgADAuthTimeout (Read/Write)
NOTE: To modify this property, you must have Configure iDRAC permission.
Legal Values

15 – 300
Default

120

366

iDRAC6 Enterprise Property Database Group and Object Definitions

Description

Specifies the number of seconds to wait for Active Directory authentication
requests to complete before timing out.

cfgADDomainController1 (Read/Write)
Legal Values

Valid IP address or a fully qualified domain name (FQDN)
Default

No default value
Description

iDRAC6 uses the value you specify to search the LDAP server for user names.

cfgADDomainController2 (Read/Write)
Valid IP address or a fully qualified domain name (FQDN)
Default

No default value
Description

iDRAC6 uses the value you specify to search the LDAP server for user names.

cfgADDomainController3 (Read/Write)
Valid IP address or a fully qualified domain name (FQDN)
Default

No default value
Description

iDRAC6 uses the value you specify to search the LDAP server for user names.

iDRAC6 Enterprise Property Database Group and Object Definitions

367

cfgADGlobalCatalog1 (Read/Write)
Legal Values

Valid IP address or a fully qualified domain name (FQDN)
Default

No default value
Description

iDRAC6 uses the value you specify to search the Global Catalog server for
user names.

cfgADGlobalCatalog2 (Read/Write)
Legal Values

Valid IP address or a fully qualified domain name (FQDN)
Default

No default value
Description

iDRAC6 uses the value you specify to search the Global Catalog server for
user names.

cfgADGlobalCatalog3 (Read/Write)
Legal Values

Valid IP address or a fully qualified domain name (FQDN)
Default

No default value
Description

iDRAC6 uses the value you specify to search the Global Catalog server for
user names.

368

iDRAC6 Enterprise Property Database Group and Object Definitions

cfgADType (Read/Write)
Legal Values

1 = Enables Active Directory with the extended schema
2 = Enables Active Directory with the standard schema
Default

1
Description

Determines the schema type to use with Active Directory

cfgADCertValidationEnable (Read/Write)
Legal Values

1 (TRUE)
0 (FALSE)
Default

1
Description

Enables or disables Active Directory certificate validation

cfgStandardSchema
This group contains parameters to configure the Active Directory standard
schema settings.

cfgSSADRoleGroupIndex (Read Only)
Legal Values

1–5

iDRAC6 Enterprise Property Database Group and Object Definitions

369

Description

Index of the Role Group as recorded in the Active Directory

cfgSSADRoleGroupName (Read/Write)
Legal Values

Any printable text string with no white space. Length is limited to 254
characters.
Default

(blank)
Description

Name of the Role Group as recorded in the Active Directory forest

cfgSSADRoleGroupDomain (Read/Write)
Legal Values

Any printable text string with no white space. Length is limited to
254 characters.
Default

(blank)
Description

Active Directory Domain in which the Role Group resides

cfgSSADRoleGroupPrivilege (Read/Write)
Legal Values

0x00000000 to 0x000001ff
Default

(blank)

370

iDRAC6 Enterprise Property Database Group and Object Definitions

Description

Use the bit mask numbers in Table B-3 to set role-based authority privileges
for a Role Group.
Table B-3.

Bit Masks for Role Group Privileges

Role Group Privilege

Bit Mask

Login to iDRAC6

0x00000001

Configure iDRAC6

0x00000002

Configure Users

0x00000004

Clear Logs

0x00000008

Execute Server Control Commands

0x00000010

Access Console Redirection

0x00000020

Access Virtual Media

0x00000040

Test Alerts

0x00000080

Execute Debug Commands

0x00000100

cfgIpmiSol
This group is used to configure the Serial Over LAN (SOL) capabilities of
the system.

cfgIpmiSolEnable (Read/Write)
Legal Values

0 (FALSE)
1 (TRUE)
Default

1
Description

Enables or disables SOL

iDRAC6 Enterprise Property Database Group and Object Definitions

371

cfgIpmiSolBaudRate (Read/Write)
Legal Values

9600, 19200, 57600, 115200
Default

115200
Description

The baud rate for serial communication over LAN

cfgIpmiSolMinPrivilege (Read/Write)
Legal Values

2 (User)
3 (Operator)
4 (Administrator)
Default

4
Description

Specifies the minimum privilege level required for SOL access

cfgIpmiSolAccumulateInterval (Read/Write)
Legal Values

1 – 255
Default

10
Description

Specifies the typical amount of time that iDRAC6 waits before transmitting a
partial SOL character data packet. This value is 1-based 5ms increments.
372

iDRAC6 Enterprise Property Database Group and Object Definitions

cfgIpmiSolSendThreshold (Read/Write)
Legal Values

1 – 255
Default

255
Description

The SOL threshold limit value. Specifies the maximum number of bytes to
buffer before sending an SOL data packet.

cfgIpmiLan
This group is used to configure the IPMI over LAN capabilities of the system.

cfgIpmiLanEnable (Read/Write)
Legal Values

0 (FALSE)
1 (TRUE)
Default

0
Description

Enables or disables the IPMI over LAN interface

cfgIpmiLanPrivLimit (Read/Write)
Legal Values

2 (User)
3 (Operator)
4 (Administrator)

iDRAC6 Enterprise Property Database Group and Object Definitions

373

Default

4
Description

Specifies the maximum privilege level allowed for IPMI over LAN access

cfgIpmiLanAlertEnable (Read/Write)
Legal Values

0 (FALSE)
1 (TRUE)
Default

0
Description

Enables or disables global e-mail alerting. This property overrides all
individual e-mail alerting enable/disable properties.

cfgIpmiEncryptionKey (Read/Write)
Legal Values

A string of hexadecimal digits from 0 to 40 characters with no spaces
Default

0000000000000000000000000000000000000000
Description

The IPMI encryption key

cfgIpmiPetCommunityName (Read/Write)
Legal Values

A string up to 18 characters

374

iDRAC6 Enterprise Property Database Group and Object Definitions

Default

public
Description

The SNMP community name for traps

cfgIpmiPef
This group is used to configure the platform event filters available on the
managed server.
The event filters can be used to control policy related to actions that are
triggered when critical events occur on the managed server.

cfgIpmiPefName (Read Only)
Legal Values

A string up to 255 characters
Default

The name of the index filter
Description

Specifies the name of the platform event filter

cfgIpmiPefIndex (Read Only)
Legal Values

1 – 17
Default

The index value of a platform event filter object
Description

Specifies the index of a specific platform event filter

iDRAC6 Enterprise Property Database Group and Object Definitions

375

cfgIpmiPefAction (Read/Write)
Legal Values

0 (None)
1 (Power Down)
2 (Reset)
3 (Power Cycle)
Default

0
Description

Specifies the action that is performed on the managed server when the alert is
triggered

cfgIpmiPefEnable (Read/Write)
Legal Values

0 (FALSE)
1 (TRUE)
Default

1
Description

Enables or disables a specific platform event filter.

cfgIpmiPet
This group is used to configure platform event traps on the managed server.

cfgIpmiPetIndex (Read/Write)
Legal Values

1–4
376

iDRAC6 Enterprise Property Database Group and Object Definitions

Default

The appropriate index value
Description

Unique identifier for the index corresponding to the trap

cfgIpmiPetAlertDestIpAddr (Read/Write)
Legal Values

String representing a valid IP address. For example, 192.168.0.67.
Default

0.0.0.0
Description

Specifies the destination IP address for the trap receiver on the network.
The trap receiver receives an SNMP trap when an event is triggered on the
managed server.

cfgIpmiPetAlertEnable (Read/Write)
Legal Values

0 (FALSE)
1 (TRUE)
Default

1
Description

Enables or disables a specific trap

iDRAC6 Enterprise Property Database Group and Object Definitions

377

378

iDRAC6 Enterprise Property Database Group and Object Definitions

iDRAC6 SM-CLP Property Database
/system1/sp1/account<1-16>
This target provides configuration information about the local users who are
allowed to access the RAC through available remote interfaces. Up to 16
instances of the user group are allowed. Each instance <1-16> represents the
configuration for an individual local user.

userid (Read Only)
Legal values

1-16
Default

Depends on the account instance being accessed.
Description

Specifies the instance ID or the local user ID.

username (Read/Write)
Legal values

String. Maximum length = 16
Default

“”

iDRAC6 SM-CLP Property Database

379

Description

A text string that contains the name of the local user for this account.
The string must not contain a forward slash (/), period (.), at symbol (@),
or quotation marks ("). Deleting the user is done by deleting the account.
(delete account<1-16>).
NOTE: This property value must be unique among usernames.

oemdell_ipmilanprivileges (Read/Write)
Legal Values

2 (User)
3 (Operator)
4 (Administrator)
15 (No access)
Default

4 (User 2)
15 (All others)
Description

The maximum privilege on the IPMI LAN channel.

password (Write Only)
Legal Values

A text string between 4 and 20 characters in length.
Default

“”
Description

Holds the password for this local user. User passwords are encrypted and
cannot be seen or displayed after the property is written.

380

iDRAC6 SM-CLP Property Database

enabledstate (Read/Write)
Legal Values

0 (Disabled)
1 (Enabled)
Default

0
Description

Helps enable or disable an individual user.

solenabled (Read/Write)
Legal Values

0 (Disabled)
1 (Enabled)
Default

0
Description

Enables or disables Serial Over LAN (SOL) user access.

oemdell_extendedprivileges (Read/Write)
Legal Values

0x00000000 to 0x000001ff
Default

0x00000000

iDRAC6 SM-CLP Property Database

381

Description

Specifies the role-based authority privileges allowed for the user. The value is
represented as a bit mask that allows for any combination of privilege values.
Table C-1 describes the user privilege bit values that can be combined to
create bit masks.
Table C-1. Bit Masks for User Privileges
User Privilege

Privilege Bit Mask

Login to iDRAC6

0x0000001

Configure iDRAC6

0x0000002

Configure Users

0x0000004

Clear Logs

0x0000008

Execute Server Control Commands

0x0000010

Access Console Redirection

0x0000020

Access Virtual Media

0x0000040

Test Alerts

0x0000080

Execute Debug Commands

0x0000100

Examples

Table C-2 provides sample privilege bit masks for users with one or more
privileges.
Table C-2. Sample Bit Masks for User Privileges
User Privilege(s)

Privilege Bit Mask

The user is not allowed to access iDRAC6.

0x00000000

The user may only login to iDRAC6 and view
iDRAC6 and server configuration information.

0x00000001

The user may login to iDRAC6 and change
configuration.

0x00000001 + 0x00000002 =
0x00000003

The user may login to RAC, access virtual media, 0x00000001 + 0x00000040 +
and access console redirection.
0x00000080 = 0x000000C1

382

iDRAC6 SM-CLP Property Database

/system1/sp1/enetport1/*
This group contains parameters to configure the iDRAC6 NIC. One instance
of the group is allowed. All objects in this group require the iDRAC6 NIC to
be reset, which may cause a brief loss in connectivity. Objects that change the
iDRAC6 NIC IP address settings close all active user sessions and require
users to reconnect using the updated IP address settings.

macaddress (Read Only)
Legal Values

A string representing the RAC NIC MAC address.
Default

The current MAC address of the iDRAC6 NIC. For example,
00:12:67:52:51:A3.
Description

Holds the iDRAC6 NIC MAC address.

/system1/sp1/enetport1/lanendpt1/ipendpt1
oemdell_nicenable (Read/Write)
Legal Values

0 (Disabled)
1 (Enabled)
Default

0
Description

Enables or disables the iDRAC6 NIC. If the NIC is disabled, the remote
network interfaces to iDRAC6 become inaccessible, rendering iDRAC6
available only through the local RACADM interface.

iDRAC6 SM-CLP Property Database

383

ipaddress (Read/Write)
Legal Values

A string representing a valid IP address. For example: 192.168.0.20.
Default

192.168.0.n (where n is 120 plus the server slot number)
Description

Specifies the static IP address to assign to the RAC. This property is only valid
if oemdell_usedhcp is set to 0 (Disabled).

subnetmask (Read/Write)
Legal Values

A string representing a valid subnet mask. For example: 255.255.255.0.
Default

255.255.255.0
Description

The subnet mask used for static assignment of the iDRAC6 IP address. This
property is only valid if oemdell_usedhcp is set to 0 (Disabled).

oemdell_usedhcp (Read/Write)
Legal Values

0 (Disabled)
1 (Enabled)
Default

0

384

iDRAC6 SM-CLP Property Database

Description

Specifies whether DHCP is used to assign the iDRAC6 IP address. If this
property is set to 1 (Enabled), the iDRAC6 IP address, subnet mask,
and gateway are assigned from the DHCP server on the network. If this
property is set to 0 (Disabled), the static IP address, subnet mask, and
gateway gain values inserted manually by the user.

committed (Read/Write)
Legal Values

0 (Pending commit)
1 (Committed)
Default

1
Description

Enables the user to change the IP address and/or subnet mask without
terminating the current session. If this property is set to 1 (Committed), the
IP address and subnet mask are valid. A change in either the IP address or the
subnet mask automatically converts this property to 0 (Pending commit). For
the network settings to take effect, the property must be set back to 1.

/system1/sp1/enetport1/lanendpt1/ipendpt1/
dnsendpt1
oemdell_domainnamefromdhcp (Read/Write)
Legal Values

0 (Disabled)
1 (Enabled)
Default

0

iDRAC6 SM-CLP Property Database

385

Description

Specifies that the iDRAC6 DNS domain name should be assigned from the
network DHCP server.

oemdell_dnsdomainname (Read/Write)
Legal Values

A string of up to 254 ASCII characters. At least one of the characters must be
alphabetic.
Default

“”
Description

Holds the DNS domain name. This parameter is only valid if
oemdell_domainnamefromdhcp is set to 0 (Disabled).

oemdell_dnsregisterrac (Read/Write)
Legal Values

0 (Unregistered)
1 (Registered)
Default

0
Description

Registers the iDRAC6 name on the DNS server.

oemdell_dnsracname (Read/Write)
Legal Values

A string of up to 63 ASCII characters. At least one character must be
alphabetic.
NOTE: Some DNS servers only register names of up to 31 characters.
386

iDRAC6 SM-CLP Property Database

Default

rac-service tag
Description

Displays the RAC name, which is the RAC service tag by default.
This parameter is only valid if oemdell_dnsregisterrac is set to 1 (Registered).

oemdell_serversfromdhcp (Read/Write)
Legal Values

0 (Disabled)
1 (Enabled)
Default

0
Description

Specifies that the DNS server IP addresses should be assigned from the
DHCP server on the network.

/system1/sp1/enetport1/lanendpt1/ipendpt1/
dnsendpt1/remotesap1
dnsserveraddress (Read/Write)
Legal Values

A string representing a valid IP address. For example: 192.168.0.20.
Default

0.0.0.0
Description

Specifies the IP address for DNS Server 1. This property is only valid if
oemdell_serversfromdhcp is set to 0 (Disabled).

iDRAC6 SM-CLP Property Database

387

/system1/sp1/enetport1/lanendpt1/ipendpt1/
dnsendpt1/remotesap2
dnsserveraddress (Read/Write)
Legal Values

A string representing a valid IP address. For example: 192.168.0.20.
Default

0.0.0.0
Description

Specifies the IP address for DNS Server 2. This property is only valid if
oemdell_serversfromdhcp is set to 0 (Disabled).

/system1/sp1/enetport1/lanendpt1/ipendpt1/
remotesap1
defaultgatewayaddress (Read/Write)
Legal Values

A string representing a valid gateway IP address. For example: 192.168.0.1.
Default

192.168.0.1
Description

The gateway IP address used for static assignment of the RAC IP address.
This property is only valid if oemdell_usedhcp is set to 0 (Disabled).

/system1/sp1/group<1-5>
These groups contain parameters to configure the Active Directory standard
schema settings.

388

iDRAC6 SM-CLP Property Database

oemdell_groupname (Read/Write)
Legal Values

Any printable text string up to 254 characters with no blank spaces.
Default

“”
Description

Holds the name of the Role Group as recorded in the Active Directory forest.

oemdell_groupdomain (Read/Write)
Legal Values

Any printable text string up to 254 characters with no blank spaces.
Default

“”
Description

Holds the Active Directory domain in which the Role Group resides.

oemdell_groupprivilege (Read/Write)
Legal Values

0x00000000 to 0x000001ff
Default

“”
Description

Use the bit mask numbers in Table B-3 to set role-based authority privileges
for a Role Group.

iDRAC6 SM-CLP Property Database

389

Table C-3. Bit Masks for Role Group Privileges
Role Group

Privilege Bit Mask

Login to iDRAC6

0x00000001

Configure iDRAC6

0x00000002

Configure Users

0x00000004

Clear Logs

0x00000008

Execute Server Control
Commands

0x00000010

Access Console Redirection

0x00000020

Access Virtual Media

0x00000040

Test Alerts

0x00000080

Execute Debug Commands

0x00000100

/system1/sp1/oemdell_adservice1
This group contains parameters to configure the iDRAC6 Active Directory
feature.

enabledstate (Read/Write)
Legal Values

0 (Disabled)
1 (Enabled)
Default

0
Description

Enables or disables Active Directory user authentication on iDRAC6. If this
property is disabled, only local iDRAC6 authentication is used for user logins.

390

iDRAC6 SM-CLP Property Database

oemdell_adracname (Read/Write)
Legal Values

Any printable text string up to 254 characters with no blank spaces.
Default

""
Description

Name of iDRAC6 as recorded in the Active Directory forest.

oemdell_adracdomain (Read/Write)
Legal Values

Any printable text string up to 254 characters with no blank spaces.
Default

""
Description

The Active Directory Domain in which iDRAC6 resides.

oemdell_adrootdomain (Read/Write)
Legal Values

Any printable text string up to 254 characters with no blank spaces.
Default

""
Description

The root domain of the Domain Forest.

iDRAC6 SM-CLP Property Database

391

oemdell_timeout (Read/Write)
Legal Values

15 – 300
Default

120
Description

Specifies the number of seconds to wait for Active Directory authentication
requests to complete before timing out.

oemdell_schematype (Read/Write)
Legal Values

1 (Extended schema)
2 (Standard schema)
Default

1
Description

Determines the schema type to use with Active Directory.

oemdell_adspecifyserverenable (Read/Write)
Legal Values

0 (Disabled)
1 (Enabled)
Default

0
Description

Enables the user to specify an LDAP or a Global Catalog server.
392

iDRAC6 SM-CLP Property Database

oemdell_addomaincontroller (Read/Write)
Legal Values

A valid IP address or a fully qualified domain name (FQDN).
Default

“”
Description

Value specified by the user that iDRAC6 uses to search the LDAP server for
usernames.

oemdell_adglobalcatalog (Read/Write)
Legal Values

A valid IP address or an FQDN.
Default

No default value
Description

Value specified by the user that iDRAC6 uses to search the Global Catalog
server for usernames.

/system1/sp1/oemdell_racsecurity1
This group is used to configure settings related to the iDRAC6 SSL certificate
signing request (CSR) feature. All of the properties in this group must be
configured before generating a CSR from iDRAC6.

commonname (Read/Write)
Legal Values

A string of up to 254 characters.

iDRAC6 SM-CLP Property Database

393

Default

""
Description

Specifies the CSR Common Name.

organizationname (Read/Write)
Legal Values

A string of up to 254 characters.
Default

""
Description

Specifies the CSR Organization Name.

oemdell_organizationunit (Read/Write)
Legal Values

A string of up to 254 characters.
Default

""
Description

Specifies the CSR Organization Unit.

oemdell_localityname (Read/Write)
Legal Values

A string of up to 254 characters.
Default

""

394

iDRAC6 SM-CLP Property Database

Description

Specifies the CSR Locality.

oemdell_statename (Read/Write)
Legal Values

A string of up to 254 characters.
Default

""
Description

Specifies the CSR State Name.

oemdell_countrycode (Read/Write)
Legal Values

A string of up to 2 characters.
Default

""
Description

Specifies the CSR Country Code.

oemdell_emailaddress (Read/Write)
Legal Values

A string of up to 254 characters.
Default

""
Description

Specifies the CSR Email Address.

iDRAC6 SM-CLP Property Database

395

oemdell_keysize (Read/Write)
Legal Values

1024
2048
4096
Default

1024
Description

Specifies the SSL asymmetric key size for the CSR.

/system1/sp1/oemdell_ssl1
Contains parameters necessary to generate Certificate Signing Requests
(CSRs) and view certificates.

generate (Read/Write)
Legal Values

0 (Do not generate)
1 (Generate)
Default

0
Description

Generates a CSR when set to 1. Set the properties in the
oemdell_racsecurity1 target before generating a CSR.

oemdell_status (Read Only)
Legal values

CSR not found
CSR generated
396

iDRAC6 SM-CLP Property Database

Default

CSR not found
Description

Shows the status of the previous generate command issued, if any, during the
current session.

oemdell_certtype (Read / Write)
Legal values

SSL
AD
CSR
Default

SSL
Description

Specifies the type of certificate to be viewed (AD or SSL) and helps generate
a CSR with the help of the generate property.

/system1/sp1/oemdell_vmservice1
This group contains parameters to configure the iDRAC6 virtual media
feature.

enabledstate (Read/Write)
Legal Values

VMEDIA_DETACH
VMEDIA_ATTACH
VMEDIA_AUTO_ATTACH
Default

VMEDIA_ATTACH
iDRAC6 SM-CLP Property Database

397

Description

Used to attach virtual devices to the system via the USB bus, allowing the
server to recognize valid USB mass storage devices attached to the system.
This is equivalent to attaching a local USB CDROM/floppy drive to
a USB port on the system. When the devices are attached, you then can
connect to the virtual devices remotely using the iDRAC6 Web interface or
the CLI. Setting this property to 0 causes the devices to detach from the
USB bus.

oemdell_singleboot (Read/Write)
Legal Values

0 (Disabled)
1 (Enabled)
Default

0
Description

Enables or disables the virtual media boot-once feature of iDRAC6. If this
property is enabled when the host server is rebooted, the server attempts to
boot from the virtual media devices.

oemdell_floppyemulation (Read/Write)
Legal Values

0 (Disabled)
1 (Enabled)
Default

0

398

iDRAC6 SM-CLP Property Database

Description

When set to 0, the virtual floppy drive is recognized as a removable disk by
Windows operating systems. Windows operating systems will assign a drive
letter that is C: or higher during enumeration. When set to 1, the Virtual
Floppy drive will be seen as a floppy drive by Windows operating systems.
Windows operating systems will assign a drive letter of A: or B:

/system1/sp1/oemdell_vmservice1/tcpendpt1
portnumber (Read/Write)
Legal Values

1 – 65535
Default

3668
Description

Specifies the port number used for encrypted virtual media connections to
iDRAC6.

oemdell_sslenabled (Read Only)
Legal Value

FALSE
Default

FALSE
Description

Indicates that the port has SSL disabled.

iDRAC6 SM-CLP Property Database

399

portnumber (Read/Write)
Legal Values

1 – 65535
Default

3670
Description

Specifies the port number used for encrypted virtual media connections to
iDRAC6.

oemdell_sslenabled (Read Only)
Legal Value

TRUE
Default

TRUE
Description

Indicates that the port has SSL enabled.

400

iDRAC6 SM-CLP Property Database

RACADM and SM-CLP
Equivalencies
Table D-1 lists the RACADM groups and objects and, where they exist,
SM-SLP equivalent locations in the SM-CLP MAP.
Table D-1.

RACADM Groups/Objects and SM-CLP Equivalencies

RACADM Groups/Objects

SM-CLP

Description

idRacInfo

idRacName

String of up to 15 ASCII
characters. Default:
iDRAC.

idRacProductInfo

String of up to 63 ASCII
characters. Default:
Integrated Dell Remote
Access Controller.

idRacDescriptionInfo

String of up to 255
ASCII characters.
Default: This system
component provides a
complete set of remote
management functions
for Dell PowerEdge
servers

idRacVersionInfo

String of up to 63 ASCII
characters. Default: 1

idRacBuildInfo

String of up to 16 ASCII
characters.

idRacType

Default: 8

RACADM and SM-CLP Equivalencies

401

Table D-1.

RACADM Groups/Objects and SM-CLP Equivalencies (continued)

RACADM Groups/Objects

SM-CLP

Description

cfgActiveDirectory

/system1/sp1/
oemdell_adservice1

cfgADEnable

enablestate

0 to disable, 1 to enable
Default: 0

cfgADRacName

oemdell_adracname

String of up to
254 characters.

cfgADRacDomain

oemdell_adracdomain

String of up to
254 characters.

cfgADAuthTimeout

oemdell_timeout

15 to 300 seconds
Default: 120

cfgADType

oemdell_schematype

1 for standard schema,
2 for extended schema
Default: 1

cfgADDomainController

oemdell_addomaincontroller

DNS name or the
IP address of the
Domain Controller used
in the LDAP search

cfgADGlobalCatalog

oemdell_adglobalcatalog

DNS name or the
IP address of the global
catalog server used in the
LDAP search

/system1/sp1/group1 through
/system1/sp1/group5

RACADM — group
index ID (1-5)

cfgStandardSchema

cfgSSADRoleGroupIndex

SM-CLP — selected
with address path
cfgSSADRoleGroupName

oemdell_groupname

String of up to
254 characters

cfgSSADRoleGroupDomain

oemdell_groupdomain

String of up to
254 characters

cfgSSADRoleGroupPrivilege

oemdell_groupprivilege

Bit mask with values
between 0x00000000
and 0x000001ff

402

RACADM and SM-CLP Equivalencies

Table D-1.

RACADM Groups/Objects and SM-CLP Equivalencies (continued)

RACADM Groups/Objects

SM-CLP

cfgLanNetworking

/system1/sp1/enetport1

cfgNicMacAddress

macaddress

Description

The MAC address of the
interface. Not editable

/system1/sp1/enetport1/
lanendpt1/ipendpt1

cfgNicEnable

oemdell_nicenable

0 to disable NIC, 1 to
enable NIC
Default: 0

cfgNicUseDHCP

oemdell_usedhcp

0 to configure static
network addresses, 1 to
use DHCP
Default: 0

cfgNicIpAddress

ipaddress

The iDRAC6 IP address
Default: 192.168.0.120
plus the server slot
number.

cfgNicNetmask

subnetmask

Subnet mask for the
iDRAC6 network
Default: 255.255.255.0

committed

When group values
change, committed is set
to 0 to indicate that the
new values have not
been saved. Set the value
to 1 to save the new
configuration.
Default: 1

/system1/sp1/enetport1/lanendpt1/
ipendpt1/dnsendpt1

cfgDNSDomainName

oemdell_dnsdomainname

String of up to 250
ASCII characters. At
least one character must
be alphabetic.

cfgDNSDomainNameFromDHCP oemdell_domainnamefromdhcp Set to 1 to get domain
name from DHCP
Default: 0

RACADM and SM-CLP Equivalencies

403

Table D-1.

RACADM Groups/Objects and SM-CLP Equivalencies (continued)

RACADM Groups/Objects

SM-CLP

Description

cfgDNSRacName

oemdell_dnsracname

String of up to 63 ASCII
characters. At least one
character must be
alphabetic.
Default: iDRAC- plus
the Dell service tag.

cfgDNSRegisterRac

oemdell_dnsregisterrac

Set to 1 to register
iDRAC6 name in DNS
Default: 0

cfgDNSServersFromDHCP

oemdell_dnsserversfromdhcp

Set to 1 to get DNS
server addresses from
DHCP
Default: 0

/system1/sp1/enetport1/lanendpt1
/ipendpt1/dnsendpt1/remotesap1

cfgDNSServer1

dnsserveraddresses1

A string representing the
IP address of a DNS
Server

/system1/sp1/enetport1/lanendpt1/
ipendpt1/dnsendpt1/remotesap2

cfgDNSServer2

dnsserveraddresses2

A string representing the
IP address of a DNS
Server

/system1/sp1/enetport1/lanendpt1/
ipendpt1/remotesap1

cfgNicGateway

defaultgatewayaddress

cfgRacVirtual

/system1/sp1/oemdell_vmservice1

cfgFloppyEmulation

oemdell_floppyemulation

404

RACADM and SM-CLP Equivalencies

A string representing the
IP address of the default
gateway
Default: 192.168.0.1

Set to 1 to enable floppy
disk emulation
Default: 0

Table D-1.

RACADM Groups/Objects and SM-CLP Equivalencies (continued)

RACADM Groups/Objects

SM-CLP

Description

cfgVirMediaAttached

enabledstate

Set to 1 (RACADM)/
VMEDIA_ATTACH
(SM-CLP) to attach
media. Default: 1
(RACADM)/
VMEDIA_ATTACH
(SM-CLP)

cfgVirMediaBootOnce

oemdell_singleboot

Set to 1 to perform next
boot from selected
media
Default 0.

/system1/sp1/oemdell_vmservice1/
tcpendpt1

cfgVirAtapiSvrPort

oemdell_sslenabled

Set to 1 if SSL is enabled
for first virtual media
device, 0 if not.
Not editable

portnumber

Port to use for first
virtual media device
Default: 3668

/system1/sp1/oemdell_vmservice1/
tcpendpt2

oemdell_sslenabled

Set to 1 if SSL is enabled
for second virtual media
device, 0 if not.
Not editable

cfgVirAtapiSvrPortSsl

portnumber

Port to use for second
virtual media device
Default: 3670

cfgUserAdmin

/system1/sp1/account1 through /
system1/sp1/account16

cfgUserAdminEnable

enabledstate

Set to 1 to enable user
Default: 0

cfgUserAdminIndex

userid

User index, from 1 to 16

RACADM and SM-CLP Equivalencies

405

Table D-1.

RACADM Groups/Objects and SM-CLP Equivalencies (continued)

RACADM Groups/Objects

SM-CLP

Description

cfgUserAdminIpmiLanPrivilege

oemdell_ipmilanprivileges

2 (user), 3 (operator),
4 (administrator),
or 15 (No access)
Default: 4

cfgUserAdminPassword

password

A string of up to
20 ASCII characters

cfgUserAdminPrivilege

oemdell_extendedprivileges

Bit mask value between
0x00000000 and
0x000001ff
Default: 0x00000000

cfgUserAdminSolEnable

solenabled

Set to 1 to allow user to
use Serial over LAN
Default: 0

cfgUserAdminUserName

username

String of up to
16 characters

cfgEmailAlert

cfgEmailAlertAddress

E-mail destination
address, up to
64 characters

cfgEmailAlertCustomMsg

Message to send in
e-mail, up to
32 characters

cfgEmailAlertEnable

Set to 1 to enable the
e-mail alert
Default: 0

cfgEmailAlertIndex

Index of the e-mail alert
instance. Number from
1 to 4

cfgSessionManagement

cfgSsnMgtConsRedirMaxSessions

406

RACADM and SM-CLP Equivalencies

Number of concurrent
console redirection
sessions allowed (1 or 2)
Default: 2

Table D-1.

RACADM Groups/Objects and SM-CLP Equivalencies (continued)

RACADM Groups/Objects

SM-CLP

Description

cfgSsnMgtSshIdleTimeout

Number of seconds idle
before a SSH session
times out. 0 to disable
timeout or
60-1920 seconds
Default: 300

cfgSsnMgtTelnetIdleTimeout

Number of seconds idle
before a telnet session
times out. 0 to disable
timeout or
60-1920 seconds
Default: 300

cfgSsnMgtWebserverTimeout

Number of seconds idle
before a Web interface
session times out.
60-1920 seconds
Default: 300

cfgRacTuning

cfgRacTuneConRedirEnable

Set to 1 to enable
console redirection, 0 to
disable
Default:1

cfgRacTuneConRedirEncrypt
Enable

Set to 1 to enable
encryption of console
redirection network
traffic, 0 to disable
Default: 1

cfgRacTuneConRedirPort

Port to use for console
redirection
Default: 5900

cfgRacTuneConRedirVideoPort

Port to use for console
video redirection
Default: 5901

cfgRacTuneHttpPort

Port to use for Web
interface HTTP
Default: 80

RACADM and SM-CLP Equivalencies

407

Table D-1.

RACADM Groups/Objects and SM-CLP Equivalencies (continued)

RACADM Groups/Objects

SM-CLP

Description

cfgRacTuneHttpsPort

Port to use for secure
Web interface HTTPS
Default: 443

cfgRacTuneIpBlkEnable

Set to 1 to enable
IP blocking
Default: 0

cfgRacTuneIPBlkFailCount

Number of failed login
attempts to count before
blocking IP (2 to 16)
Default: 5

cfgRacTuneIpBlkFailWindow

Time span in seconds
during which to count
failed login attempts
(10 to 65535)
Default: 60

cfgRacTuneIpBlkPenaltyTime

Time span in seconds
that a blocked
IP remains blocked
(10 to 65535)
Default: 300

cfgRacTuneIpRangeAddr

Base IP address for
IP range filter
Default: 192.168.0.1

cfgRacTuneIpRangeEnable

Set to 1 to allow IP range
filtering
Default: 0

cfgRacTuneIpRangeMask

Bit mask applied to the
base address to select
valid IP addresses
Default: 255.255.255.0

cfgRacTuneLocalServerVideo

Set to 1 to enable local
iKVM console
Default: 1

cfgRacTuneSshPort

Port to use for the SSH
service
Default: 22

408

RACADM and SM-CLP Equivalencies

Table D-1.

RACADM Groups/Objects and SM-CLP Equivalencies (continued)

RACADM Groups/Objects

SM-CLP

Description

cfgRacTuneTelnetPort

Port to use for the telnet
service
Default: 23

cfgRacTuneWebserverEnable

Set to 1 to enable the
iDRAC6 Web interface
Default: 1

ifcRacManagedNodeOS

ifcRacMnOsHostname

Host name of the
managed server. String of
up to 255 characters

ifcRacMnOsOsName

Name of the managed
server operating system.
A string of up to
255 characters

cfgRacSecurity

/system1/sp1/oemdell_racsecurity1

cfgRacSecCsrCommonName

commonname

Active Directory
common name. String of
up to 254 characters

cfgRacSecCsrCountryCode

oemdell_countrycode

Active Directory country
code. Two characters

cfgRacSecCsrEmailAddr

oemdell_emailaddress

E-mail address to use for
Certificate Signing
Request. String of up to
254 characters

cfgRacSecCsrKeySize

oemdell_keysize

Length of encryption key
(512, 1024, or 2048)
Default: 1024

cfgRacSecCsrLocalityName

oemdell_localityname

Active Directory locality
name. String of up to
254 characters

cfgRacSecCsrOrganizationName

organizationname

Active Directory
organization name.
String of up to
254 characters

RACADM and SM-CLP Equivalencies

409

Table D-1.

RACADM Groups/Objects and SM-CLP Equivalencies (continued)

RACADM Groups/Objects

SM-CLP

Description

cfgRacSecCsrOrganizationUnit

oemdell_organizationunit

Active Directory
organization unit name.
String of up to
254 characters

cfgRacSecCsrStateName

oemdell_statename

Activity Directory state
name. String of up to
254 characters

cfgIpmiSol

cfgIpmiSolAccumulateInterval

Maximum number of
milliseconds to wait
before sending a partial
Serial over LAN packet
(1 to 255)
Default: 10

cfgIpmiSolBaudRate

Baud rate to use for
Serial over LAN (19200,
57600, 115200)
Default: 115200

cfgIpmiSolEnable

Set to 1 to enable Serial
over LAN feature
Default: 0

cfgIpmiSolSendThreshold

Maximum number of
characters to collect
before sending SOL data
(1 to 255)
Default: 255

cfgIpmiSolMinPrivilege

Minimum privilege
required to use SOL.
2 (user), 3 (operator),
or 4 (administrator)
Default: 4

cfgIpmiLan

cfgIpmiEncryptionKey

410

RACADM and SM-CLP Equivalencies

A string of 0 to 40
hexadecimal digits
Default:
00000000000000000000
00000000000000000000

Table D-1.

RACADM Groups/Objects and SM-CLP Equivalencies (continued)

RACADM Groups/Objects

SM-CLP

Description

cfgIpmiLanAlertEnable

Set to 1 to enable
IPMI LAN alerts
Default: 0

cfgIpmiLanEnable

Set to 1 to enable the
IPMI over LAN interface
Default: 0

cfgIpmiPetCommunityName

A string of up to
18 characters
Default: public

cfgIpmiPef

cfgIpmiPefAction

The action to take when
event is detected. 0
(none), 1 (power down),
2 (reset), 3 (power cycle)
Default: 0

cfgIpmiPefEnable

Set to 1 to enable
platform event filtering
Default: 0

cfgIpmiPefIndex

The index number of the
platform event filter.
(1 - 17)

cfgIpmiPefName

The name of the
platform event, a string
of up to 254 characters.
Not editable

cfgIpmiPet

cfgIpmiPetAlertDestIpAddr

IP address of the
platform event trap
receiver.
Default: 0.0.0.0

cfgIpmiPetAlertEnable

Set to 1 to enable the
platform event trap
Default: 1

cfgIpmiPetIndex

Index number (1-4) of
the platform event trap

RACADM and SM-CLP Equivalencies

411

Table D-2. RACADM Subcommands and SM-CLP Equivalencies
RACADM Subcommand

SM-CLP

Description

sslcsrgen -g

set /system1/sp1/oemdell_ssl1
oemdell_certtype=CSR

Generates and
downloads an SSL
Certificate Signing
Request (CSR)

set /system1/sp1/oemdell_ssl1
generate=1
dump -destination  /system1/sp1/
oemdell_ssl1
sslcsrgen -s

show /system1/sp1/oemdell_ssl1 Returns the status of a
oemdell_status
CSR generation process

sslcertupload -t 1

set /system1/sp1/oemdell_ssl1
oemdell_certtype=SSL
load -source  /
system1/sp1/oemdell_ssl1

sslcertupload -t 2

set /system1/sp1/oemdell_ssl1
oemdell_certtype=AD

sslcertdownload -t 1

set /system1/sp1/oemdell_ssl1
oemdell_certtype=SSL

Uploads the Active
Directory Certificate
load -source  /
system1/sp1/oemdell_ssl1

load -source  /
system1/sp1/oemdell_ssl1
sslcertdownload -t 2

412

Uploads the iDRAC6
Server Certificate onto
iDRAC6

set /system1/sp1/oemdell_ssl1
oemdell_certtype=AD

Downloads the iDRAC6
Sever Certificate from
iDRAC6

Downloads the Active
Directory Certificate
load -source  /
system1/sp1/oemdell_ssl1

RACADM and SM-CLP Equivalencies

Glossary
Active Directory

Active Directory is a centralized and standardized system that automates network
management of user data, security, and distributed resources, and enables
interoperation with other directories. Active Directory is designed especially for
distributed networking environments.
AGP

Abbreviation for accelerated graphics port, which is a bus specification that allows
graphics cards faster access to main system memory.
ARP

Acronym for Address Resolution Protocol, which is a method for finding a host’s
Ethernet address from its Internet address.
ASCII

Acronym for American Standard Code for Information Interchange, which is a
code representation used for displaying or printing letters, numbers, and other
characters.
BIOS

Acronym for basic input/output system, which is the part of system software that
provides the lowest-level interface to peripheral devices and which controls the
first stage of the system boot process, including installation of the operating
system into memory.
CMC

Abbreviation for enclosure Management Controller, which is the controller
interface between iDRAC6 and the managed system’s CMC.
bus

A set of conductors connecting the various functional units in a computer. Busses
are named by the type of data they carry, such as data bus, address bus, or PCI bus.

Glossary

413

CA

A certificate authority is a business entity that is recognized in the IT industry for
meeting high standards of reliable screening, identification, and other important
security criteria. Examples of CAs include Thawte and VeriSign. After the
CA receives your CSR, they review and verify the information the CSR contains.
If the applicant meets the CA’s security standards, the CA issues a certificate to
the applicant that uniquely identifies that applicant for transactions over
networks and on the Internet.
CD

Abbreviation for compact disc.
CHAP

Acronym for Challenge-Handshake Authentication Protocol, which is an
authentication method used by PPP servers to validate the identity of the
originator of the connection.
CIM

Acronym for Common Information Model, which is a protocol designed for
managing systems on a network.
CLI

Abbreviation for command-line interface.
CLP

Abbreviation for command-line protocol.
console redirection

Console redirection is a function that directs a managed server’s display screen,
mouse functions, and keyboard functions to the corresponding devices on a
management station. You may then use the management station’s system console
to control the managed server.
CSR

Abbreviation for Certificate Signing Request.
DHCP

Abbreviation for Dynamic Host Configuration Protocol, which is a protocol that
provides a means to dynamically allocate IP addresses to computers on a local
area network.

414

Glossary

DLL

Abbreviation for Dynamic Link Library, which is a library of small programs, any of
which can be called when needed by a larger program that is running in the system.
The small program that lets the larger program communicate with a specific
device such as a printer or scanner is often packaged as a DLL program (or file).
DDNS

Abbreviation for Dynamic Domain Name System.
DMTF

Abbreviation for Distributed Management Task Force.
DNS

Abbreviation for Domain Name System.
iDRAC6

Abbreviation for Dell Remote Access Controller 6 Enterprise.
DSU

Abbreviation for disk storage unit.
extended schema

A solution used with Active Directory to determine user access to iDRAC6;
uses Dell-defined Active Directory objects.
FQDN

Acronym for Fully Qualified Domain Names. Microsoft® Active Directory® only
supports FQDN of 64 bytes or fewer.
FSMO

Flexible Single Master Operation. It is Microsoft’s way of guaranteeing atomicity
of the extension operation.
GMT

Abbreviation for Greenwich Mean Time, which is the standard time common to
every place in the world. GMT nominally reflects the mean solar time along the
prime meridian (0 longitude) that runs through the Greenwich Observatory
outside of London, UK.
GPIO

Abbreviation for general purpose input/output.
Glossary

415

GRUB

Acronym for GRand Unified Bootloader, a new and commonly-used Linux loader.
GUI

Abbreviation for graphical user interface, which refers to a computer display
interface that uses elements such as windows, dialog boxes, and buttons as
opposed to a command prompt interface, in which all user interaction is displayed
and entered in text.
hardware log

Records events generated by iDRAC6 and the CMC.
iAMT

Intel® Active Management Technology — Delivers more secure systems
management capabilities whether or not the computer is powered up or turned
off, or the operating system is not responding.
ICMB

Abbreviation for Intelligent enclosure Management Bus.
ICMP

Abbreviation for Internet control message protocol.
ID

Abbreviation for identifier, commonly used when referring to a user identifier
(user ID) or object identifier (object ID).
iDRAC6

Acronym for integrated Dell Remote Access Controller 6, the integrated
System-on-Chip monitor/control system for the Dell 10G PowerEdge servers.
IP

Abbreviation for Internet Protocol, which is the network layer for TCP/IP.
IP provides packet routing, fragmentation, and reassembly.
IPMB

Abbreviation for intelligent platform management bus, which is a bus used in
systems management technology.

416

Glossary

IPMI

Abbreviation for Intelligent Platform Management Interface, which is a part of
systems management technology.
Kbps

Abbreviation for kilobits per second, which is a data transfer rate.
LAN

Abbreviation for local area network.
LDAP

Abbreviation for Lightweight Directory Access Protocol.
LED

Abbreviation for light-emitting diode.
LOM

Abbreviation for Local area network On Motherboard.
MAC

Acronym for media access control, which is a network sublayer between a network
node and the network physical layer.
MAC address

Acronym for media access control address, which is a unique address embedded
in the physical components of a NIC.
managed server

The managed server is the system in which iDRAC6 is embedded.
management station

The management station is a system that remotely accesses iDRAC6.
MAP

Abbreviation for Manageability Access Point.
Mbps

Abbreviation for megabits per second, which is a data transfer rate.

Glossary

417

MIB

Abbreviation for management information base.
MII

Abbreviation for Media Independent Interface.
NAS

Abbreviation for network attached storage.
NIC

Abbreviation for network interface card. An adapter circuit board installed in a
computer to provide a physical connection to a network.
OID

Abbreviation for Object Identifiers.
OSCAR

Acronym for On Screen Configuration and Reporting. OSCAR is the menu
displayed by the Avocent iKVM when you press . It allows you to
select the CMC console or the iDRAC6 console for a server installed in the CMC.
PCI

Abbreviation for Peripheral Component Interconnect, which is a standard
interface and bus technology for connecting peripherals to a system and for
communicating with those peripherals.
POST

Acronym for power-on self-test, which is a sequence of diagnostic tests that are
run automatically by a system when it is powered on.
PPP

Abbreviation for Point-to-Point Protocol, which is the Internet standard
protocol for transmitting network layer datagrams (such as IP packets) over
serial point-to-point links.
RAM

Acronym for random-access memory. RAM is general-purpose readable and
writable memory on systems and iDRAC6.

418

Glossary

RAM disk

A memory-resident program which emulates a hard drive. iDRAC6 maintains a
RAM disk in its memory.
RAC

Abbreviation for remote access controller.
ROM

Acronym for read-only memory, which is memory from which data may be read,
but to which data cannot be written.
RPM

Abbreviation for Red Hat® Package Manager, which is a package-management
system for the Red Hat Enterprise Linux® operating system that helps installation
of software packages. It is similar to an installation program.
SAC

Acronym for Microsoft’s Special Administration Console.
SAP

Abbreviation for Service Access Point.
SEL

Acronym for system event log.
SMI

Abbreviation for systems management interrupt.
SMTP

Abbreviation for Simple Mail Transfer Protocol, which is a protocol used to
transfer electronic mail between systems, usually over an Ethernet.
SMWG

Abbreviation for Systems Management Working Group.
SNMP trap

A notification (event) generated by iDRAC6 or the CMC that contains
information about state changes on the managed server or about potential
hardware problems.

Glossary

419

SSH

Abbreviation for Secure Shell.
SSL

Abbreviation for secure sockets layer.
standard schema

A solution used with Active Directory to determine user access to iDRAC6;
uses Active Directory group objects only.
TAP

Abbreviation for Telelocator Alphanumeric Protocol, which is a protocol used for
submitting requests to a pager service.
TCP/IP

Abbreviation for Transmission Control Protocol/Internet Protocol, which
represents the set of standard Ethernet protocols that includes the network layer
and transport layer protocols.
TFTP

Abbreviation for Trivial File Transfer Protocol, which is a simple file transfer
protocol used for downloading boot code to diskless devices or systems.
UPS

Abbreviation for uninterruptible power supply.
USB

Abbreviation for Universal Serial Bus.
UTC

Abbreviation for Universal Coordinated Time. See GMT.
VLAN

Abbreviation for Virtual Local Area Network.

420

Glossary

VNC

Abbreviation for virtual network computing.
VT-100

Abbreviation for Video Terminal 100, which is used by the most common terminal
emulation programs.
WAN

Abbreviation for wide area network.

Glossary

421

422

Glossary

Index
A

C

Active Directory
adding DRAC 5 users, 126
configuring access to the DRAC
5, 119
logging in to the DRAC 5, 142
managing certificates, 100
objects, 116
schema extensions, 115
using with extended schema, 115
using with standard schema, 132
using with the DRAC 5, 113

Certificate Signing Request.
See CSR

ActiveX
console redirection plug-in, 190
alert management. See PEF
arp command, diagnostics
console, 294
ASR
auto recovery action, 292
auto recovery timer, 76
configuring, 106
Automated System Recovery,
See ASR

certificates
Active Directory, 100
exporting the root CA
certificate, 140
SSL and digital, 94
uploading a server certificate, 98
viewing a server certificate, 99
chassis LCD panel, 39
Chassis Management Controller.
See CMC
CMC
about, 27
configuring iDRAC during
initialization, 41
IP address, locating, 45
CMC Web interface, 38
configuring iDRAC network
properties, 45
locating the iDRAC IP
address, 297
community string, SNMP, 375

B
boot once, enabling, 209
bootable image file
creating, 258

configuration file
creating, 237
configuring
task overview, 41-44

Index

423

configuring multiple iDRACs
with RACADM, 241
console redirection
configuring, 187
opening a session, 189
using, 163, 185
CSR
about, 95
generating, 97

D
diagnostics console, 294
digital signature, verify, 53-56
Distributed Management Task
Force (DMTF), 243

F
Firefox
tab behavior, 81
viewing localized version, 66
firewall, opening ports, 33
firmware
recovering with CMC, 51, 109
updating, 48
updating with SM-CLP, 251
updating with the web
interface, 109
frequently asked questions
using console redirection, 196
using the DRAC 5 with Active
Directory, 143
using Virtual Media, 213

documents you may need, 34
DOS update utility, 52

G

DRAC 5
configuring, 128, 134

gettracelog command,
diagnostics console, 294
group permissions
table of, 93

E
e-mail alerts
configuring with RACADM, 230
configuring with the web
interface, 89
extended schema
using with Active Directory, 115

424

Index

I
iDRAC
creating a configuration file, 237
log, viewing, 290
recovering firmware, 111
securing communications, 94
system information, 292
updating the firmware, 48

iDRAC configuration utility
configuring LAN user, 273
configuring network
properties, 270
iDRAC KVM
displaying OSCAR, 268
iDRAC service ports, 33
iDRAC6
resetting to factory defaults, 273
SSH, 71
iDRAC6 configuration utility, 38
configuring IPMI, 269
configuring network
properties, 269
configuring virtual media, 272
starting, 268
iDRAC6 web interface, 38, 51
ifconfig command, diagnostics
console, 294
iKVM
disabling during console
redirection, 195
finding the iDRAC IP
address, 297
viewing status of the local
console, 197
instrumentation
server, 75
Intelligent Platform
Management Interface.
See IPMI

IP address
CMC, locating, 45
IP blocking
configuring with RACADM, 234
configuring with the web
interface, 85
enabling, 235
IP filtering
configuring with RACADM, 231
configuring with the web
interface, 85
enabling, 232
IPMI, 40
configuring LAN properties, 82
configuring with RACADM, 227
configuring with the iDRAC6
configuration utility, 269
configuring with the web
interface, 90
iVMCLI, 39
iVMCLI utility
about, 257
deploying the operating
system, 259
operating system shell
options, 265
parameters, 262
return codes, 266
syntax, 262
using, 260
ivmdeploy script, 259

Internet Explorer
configuring, 62

Index

425

J
Java
console redirection
plug-in, 69, 190

K
key, verify, 54, 56

L
last crash screen
capturing on the managed
server, 76
viewing, 280
local RACADM, 39
localization, browser setup, 65
logs
iDRAC, 290
post codes, 279
See also SEL
server, 75
lost administrative
password, 273

M
Manageability Access Point.
See MAP
managed server
capturing the last crash screen, 76
configuring, 75

426

Index

management
storage, 75
management station
configuring, 61-69
configuring for console
redirection, 186
installing the software, 73
network requirements, 61
MAP
navigating
Media Redirection wizard, 210211
mouse pointer
synchronizing, 194
Mozilla Firefox
disabling whitelist, 68
supported versions, 68

N
netstat command, diagnostics
console, 294
network properties
configuring manually, 225
configuring with RACADM, 225
configuring with the CMC Web
interface, 45
configuring with the iDRAC
configuration utility, 270
configuring with the iDRAC6
configuration utility, 269
configuring with the Web
interface, 82

O

Platform Event Filter. See PEF

On Screen Configuration and
Reporting. See OSCAR

Platform Event Trap. See PET

OpenSSH, SSH client for
Linux, 71
operating system
installing (manual method), 212
installing (scripted method), 257
OSCAR
displaying, 268

platforms
supported, 30
ports
table of, 33
post codes, viewing, 279
power management
using SM-CLP, 250
using the web interface, 295

PET
configuring with RACADM, 229
configuring with the web
interface, 87-88, 229
filterable platform events
table, 87

property database groups
cfgActiveDirectory, 365
cfgEmailAlert, 344
cfgIpmiLan, 373
cfgIpmiPef, 375
cfgIpmiPet, 376
cfgIpmiSol, 371
cfgLanNetworking, 335
cfgRacSecurity, 360
cfgRacTuning, 353
cfgRacVirtual, 363
cfgSerial, 348
cfgSessionManagement, 345
cfgUserAdmin, 340
idRacInfo, 331
ifcRacManagedNodesOs, 360

ping command, diagnostics
console, 294

proxy server, web browser
configuration, 65

P
password
changing, 92
lost, 273
PEF
configuring with RACADM, 229
configuring with the web
interface, 88

public key, verify, 54, 56
PuTTY, Windows SSH client, 71

Index

427

R
RACADM
configuring e-mail alerts, 230
configuring IP blocking, 234
configuring IP filtering, 231
configuring IPMI, 227
configuring multiple
iDRACS, 241
configuring network
properties, 225
configuring PEF, 229
configuring PET, 229
configuring SOL, 228
configuring SSH service, 236
configuring telnet service, 236
subcommands, 301
using, 219
RACADM subcommands
clrraclog, 220, 317
clrsel, 220, 319
config, 76, 220, 302
getconfig, 197, 220, 237, 304
getniccfg, 220, 312
getraclog, 220, 316
getractime, 220, 310
getsel, 317
getssninfo, 220, 306
getsvctag, 220, 313
getsysinfo, 220, 307
gettracelog, 220, 319
help, 301
racreset, 221, 313

racresetcfg, 221, 314
serveraction, 221, 315
setniccfg, 221, 311
sslcertdownload, 221, 323
sslcertupload, 221, 322
sslcertview, 221, 324
sslcsrgen, 221, 321
testemail, 221, 326
testtrap, 221, 328
reboot option
disabling, 77
remote access connections
supported, 32
resetting iDRAC6 to
defaults, 273

S
safety, 275
screen resolutions, support, 186
scripts
ivmdeploy, 259
secure shell. See SSH
Secure Sockets Layer (SSL)
importing the firmware
certificate, 141
secure sockets layer. See SSL
security
using SSL and digital
certificates, 94
See RACADM

428

Index

SEL
managing with SM-CLP, 251
managing with the iDRAC6
configuration
utility, 273-274
managing with the web
interface, 279
server
instrumentation, 75
logs, 75
server certificate
uploading, 98
viewing, 99
server features, integrated
instrumentation, 75
logs, 75
Server Management Command
Line Protocol. See SM-CLP
server storage management, 75
services
configuring with the web
interface, 106
signature, verify, 53-56
Simple Network Management
Protocol. See SNMP
SM-CLP, 40
features, 244
navigating the MAP
output formats, 249
power management, 250
syntax, 244

targets, 249
updating iDRAC firmware, 251
using the show verb, 249
snap-in
installing the Dell extension, 125
SNMP
community string, 375
testing trap alert, 225
SOL
configuring with RACADM, 228
configuring with the web
interface, 90
SSH
client installation, 70
configuring iDRAC service with
RACADM, 236
configuring service with the web
interface, 106
OpenSSH software for Linux, 71
PuTTY client for Windows, 71
SSL
about, 95
standard schema
using with Active Directory, 132
System Event Log. See SEL
system health, viewing, 278
system information
iDRAC, 292
main system enclosure, 292
System Services Configuration
Unified Server Configurator, 272

Index

429

T
telnet
backspace configuration, 70
client installation, 70
configuring iDRAC service with
RACADM, 236
configuring iDRAC service with
the web interface, 106
TFTP server, installing, 72
Trivial File Transfer Protocol,
see TFTP
troubleshooting
indications, 276
trusted domains list, adding
iDRAC, 65

U
Unified Server Configurator, 272
System Services, 272
Update Packages
verifying the digital
signature, 53-56

utilities
dd, 258
iVMCLI, 257
video viewer, 191

V
verify
digital signature, 53-56
public key, 54, 56
video viewer
using, 191
virtual media
about, 205
booting, 211
command line, 260
configuring with the iDRAC6
configuration utility, 272
configuring with the web
interface, 208
installing the operating
system, 212
running, 209

USB flash drive emulation
type, 272

W

users
adding and configuring with the
web interface, 91
configuring LAN user with the
iDRAC configuration
utility, 273

web browser
configuring, 62
proxy server configuration, 65
supported browsers, 31

430

Index

web interface
accessing, 80
browser configuration, 62
configuring ASR service, 106
configuring e-mail alerts, 89
configuring iDRAC services, 106
configuring IP blocking, 85
configuring IP filtering, 85
configuring IPMI LAN
properties, 82, 90
configuring network
properties, 82
configuring PEF, 88
configuring PET, 87-88, 229
configuring SOL, 90
configuring telnet service, 106
configuring the SSH service, 106
configuring the web server
service, 106
logging in, 80
logging out, 81
updating firmware, 109
web server, iDRAC
configuring with the web
interface, 106

Index

431

432

Index


Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : No
Page Count                      : 432
Page Mode                       : UseOutlines
Format                          : application/pdf
Title                           : iDRAC6 Enterprise for Blade Servers Version 2.0 User Guide
Creator                         : Dell Inc.
Subject                         : User's Guide
Description                     : User's Guide
Producer                        : Acrobat Distiller 7.0.5 (Windows); modified using iTextSharp 5.1.3 (c) 1T3XT BVBA
Keywords                        : all-products#esuprt_electronics#esuprt_software#esuprt_ent_sys_mgmt#integrated dell remote access cntrllr 6 ent for blade srvr v2.0#integrated-dell-remote-access-cntrllr-6-ent-for-blade-srvr-v2.0#User's Guide
Modify Date                     : 2013:12:24 12:41:44-06:00
Create Date                     : 2009:03:18 11:04:06Z
Creator Tool                    : FrameMaker 7.1
Author                          : Dell Inc.
Productcode                     : integrated-dell-remote-access-cntrllr-6-ent-for-blade-srvr-v2.0
Typecode                        : ug
Typedescription                 : User's Guide
Languagecodes                   : en-us
Sectioncode                     : 
Sectiondescription              : 
Publishdate                     : 2009-03-24 00:00:00
Expirydate                      : 9999-09-09 00:00:00
Manualurl                       : http://ftp.dell.com/manuals/all-products/esuprt_electronics/esuprt_software/esuprt_ent_sys_mgmt/integrated-dell-remote-access-cntrllr-6-ent-for-blade-srvr-v2.0_User's Guide_en-us.pdf
Readytocopy                     : false
Futureproductindication         : yes
Categorypathforfutureproducts   : all-products/esuprt_electronics/esuprt_software/esuprt_ent_sys_mgmt
Businesskeywords                : 
Filesize                        : 3278
Moddate                         : D:20121107060906-06'00'
Creationdate                    : D:20090318110406Z
EXIF Metadata provided by EXIF.tools

Navigation menu