Dell Server Management Pack Version 4 1 For Microsoft System Center Operations Manager Users Manual 4.1 User's Guide

2014-11-13

: Dell Dell-Server-Management-Pack-Version-4-1-For-Microsoft-System-Center-Operations-Manager-Users-Manual-117881 dell-server-management-pack-version-4-1-for-microsoft-system-center-operations-manager-users-manual-117881 dell pdf

Open the PDF directly: View PDF PDF.
Page Count: 72

DownloadDell Dell-Server-Management-Pack-Version-4-1-For-Microsoft-System-Center-Operations-Manager-Users-Manual- Server Management Pack Version 4.1 For Microsoft System Center Operations Manager User's Guide  Dell-server-management-pack-version-4-1-for-microsoft-system-center-operations-manager-users-manual
Open PDF In BrowserView PDF
book.book Page 1 Wednesday, December 8, 2010 7:33 PM

Dell Server Management Pack
Suite Version 4.1 For Microsoft
System Center Operations
Manager 2007 SP1/R2, System
Center Essentials 2007 SP1/
2010

User’s Guide

book.book Page 2 Wednesday, December 8, 2010 7:33 PM

Notes and Cautions
NOTE: A NOTE indicates important information that helps you make better use of
your computer.
CAUTION: A CAUTION indicates either potential damage to hardware or loss of
data and tells you how to avoid the problem.

____________________
Information in this document is subject to change without notice.
© 2010 Dell Inc. All rights reserved.
Reproduction of these materials in any manner whatsoever without the written permission of Dell Inc.
is strictly forbidden.
Trademarks used in this text: Dell™, the DELL logo, PowerEdge™, PowerVault™, and
OpenManage™ are trademarks of Dell Inc. Broadcom® is a registered trademark of Broadcom
Corporation. Intel® is a registered trademark of Intel Corporation in the United States and/or other
countries. Microsoft®, Windows®, Windows Server®, and Windows Vista® are either trademarks or
registered trademarks of Microsoft Corporation in the United States. Other trademarks and trade
names may be used in this publication to refer to either the entities claiming the marks and names or
their products. Dell Inc. disclaims any proprietary interest in trademarks and trade names other than
its own. Dell is not responsible for the availability of external websites or their contents.
December 2010

book.book Page 3 Wednesday, December 8, 2010 7:33 PM

Contents
1

Introduction .

. . . . . . . . . . . . . . . . . . . . . . .

Contents of the Management Pack Suite

. . . . . . . . .

What is New in Dell Server Management Pack
Suite Version 4.1 . . . . . . . . . . . . . . . . .
Key Features of Dell Server Management
Pack Suite . . . . . . . . . . . . . . . . .

2

7

. . . . .

8

. . . . . . . .

9

About Dell Server Management Pack Suite v4.1
Supported Dell Devices

7

. . . .

11

. . . . . . . . . . . . . . . . .

13

Supported Operating Systems .

. . . . . . . . . . . . .

14

Supported Firmware Versions

. . . . . . . . . . . . .

15

. . . . . . . . . . . . . . . . . . . .

17

Getting Started

Management Server (MS) Requirements

. . . . . . . .

17

Software Requirements

. . . . . . . . . . . . . .

17

Discovery Requirements

. . . . . . . . . . . . . .

18

. . . . . . . . . . . . . . .

18

Security Configuration

Chassis Modular Server Correlation
Requirement . . . . . . . . . . . . .
Managed System Requirements
Dell System Requirements

. . . . . . .

19

. . . . . . . . . . . .

19

. . . . . . . . . . . . .

19

Configuring Management Server Action
Account With Normal User Privilege . .

. . . . .

Contents

21

3

book.book Page 4 Wednesday, December 8, 2010 7:33 PM

Dell CMC/DRAC MC Requirements

. . . . . . . .

Installing the Dell Server Management Pack
Suite v4.1 . . . . . . . . . . . . . . . . . . . .
Pre-import Tasks

21

. . . . .

21

. . . . . . . . . . . . . . . . . .

21

Importing the Management Packs

. . . . . . . . .

Post-Import Tasks for the Dell Server Management
Pack Suite v4.1 . . . . . . . . . . . . . . . . . . .

. .

22
23

Configuring the Dell Chassis Management Controller
Management Pack for Discovering Server Modules
and Chassis Slot Summary . . . . . . . . . . . . . 23
Creating Advanced Power Control and LED
Identification Tasks . . . . . . . . . . . . .

. . . .

24

. . . . . .

26

. . . . . . .

26

. . . . . . . . . . . . . . . .

26

Upgrading From the Previous Management
Packs . . . . . . . . . . . . . . . . . . . .
From Dell Server Management Pack
Suite v4.0 . . . . . . . . . . . . . . .
Post Upgrade Tasks

From Dell Server Management Pack 3.x

. . . . . .

Uninstalling the Dell Server Management Pack
Suite v4.1 . . . . . . . . . . . . . . . . . . . . .
Deleting the Management Packs

. . . .

27

. . . . . . . . .

27

Before deleting the Dell CMC Management
Pack 4.1 . . . . . . . . . . . . . . . . . . .
Access Privileges

3

. . . .

28

. . . . . . . . . . . . . . . . . . . .

29

Understanding Dell Server Management
Pack Suite Operations . . . . . . . . . . . . . . 31
Overview .

. . . . . . . . . . . . . . . . . . . . . . . .

Web Console .

. . . . . . . . . . . . . . . . . . . . . .

Discovery and Grouping

4

27

Contents

. . . . . . . . . . . . . . . . .

31
31
32

book.book Page 5 Wednesday, December 8, 2010 7:33 PM

Discovering a Dell System

. . . . . . . . . . . . .

Discovering DRAC and CMC Devices

. . . . . . .

Dell Hardware Discovery and Grouping

. . . . . .

Objects Discovered by Dell Server Management
Pack . . . . . . . . . . . . . . . . . . . . . . .
Monitoring .

33
34

.

35

. . . . . . . . . . . . . . . . . . . . . . .

37

Alerts View

. . . . . . . . . . . . . . . . . . . . .

Diagram View
State View

38

. . . . . . . . . . . . . . . . . . .

39

. . . . . . . . . . . . . . . . . . . . .

49

Performance and Power Monitoring Views
Tasks .

32

. . . .

49

. . . . . . . . . . . . . . . . . . . . . . . . . .

51

Dell Modular and Monolithic Systems Tasks

. . .

52

Dell Remote Access Controller (DRAC) Tasks

. . .

56

Dell Chassis Management Controller (CMC)
Tasks . . . . . . . . . . . . . . . . . . . . .

. . .

56

. . . . . . . . . . . . . . . . . . . . . . . . .

57

Reports .

. . . . . . . .

57

. . . . . . . . . . . . . . . .

58

OpenManage Windows Event Log .
BIOS Configuration .

Firmware and Driver Versions
RAID Configuration .

. . . . . . . . . . .

58

. . . . . . . . . . . . . . . .

58

Customizing the Dell Server Management Pack
Suite . . . . . . . . . . . . . . . . . . . . . . .
Unit Monitors .

. . . .

59

. . . . . . . . . . . . . . . . . . .

59

Object Discoveries
Rules

. . . . . . . . . . . . . . . . .

64

. . . . . . . . . . . . . . . . . . . . . . . .

64

Contents

5

book.book Page 6 Wednesday, December 8, 2010 7:33 PM

4

Related Documentation and
Resources . . . . . . . . . . . . . .

. . . . . . . . . .

Microsoft Guidelines for Performance and
Scalability for Operations Manager 2007 SP1/R2 .

67

. . .

67

Other Documents You May Need

. . . . . . . . . . . .

67

Obtaining Technical Assistance

. . . . . . . . . . . .

68

. . . . . . . . . . . . . . . . . . .

72

A Appendix A- Issues and
Resolutions 69
Known Limitations

6

Contents

book.book Page 7 Wednesday, December 8, 2010 7:33 PM

1

Introduction

The integration of the Dell Server Management Pack Suite v4.1 with
Microsoft Systems Center Operations Manager (SCOM) 2007 SP1/R2,
System Center Essentials (SCE) 2007 SP1/ 2010 environment allows you to
manage, monitor, and ensure the availability of your Dell devices.
CAUTION: Perform the procedures in this document only if you have proper
knowledge and experience in using Microsoft Windows operating system and the
Systems Center Operations Manager 2007 SP1/R2, System Center Essentials 2007
SP1/2010, to avoid data corruption and/or data loss.
NOTE: Read the Management Pack’s readme files, which contain the latest
information about software and management server requirements, in addition to
information about known issues. The readme files are posted to the Systems
Management documentation page on the Dell Support website at
support.dell.com/manuals. The readme files are also packaged in the selfextracting executable Dell_Server_Management_Pack_Suite_v4.1_A00.exe file.
NOTE: All references to Systems Center Operations Manager (SCOM) 2007 SP1/R2
in this document are also applicable to System Center Essentials (SCE) 2007
SP1/2010.

Contents of the Management Pack Suite
The Dell Server Management Pack Suite v4.1 consists of the following:
Management Packs:
•

Dell.WindowsServer.Scalable.mp

•

Dell.WindowsServer.Detailed.mp

•

Dell.OutOfBand.CMC.mp

•

Dell.OutOfBand.DRAC.mp

Utilities:
•

Dell.Connections.HardwareLibrary.mp (Base Folder utility)

•

Dell.WindowsServer.InformationalAlertsOn.mp

•

Dell.ChassisModularServer.Correlation.mp

Introduction

7

book.book Page 8 Wednesday, December 8, 2010 7:33 PM

Documentation:
•

DellMPv41_Readme

•

DellMPv41_CMC_Readme

•

DellMPv41_DRAC_Readme

•

DellMPv41_Server_Readme

The four Management Pack files, three utilities, and readme files are packaged
in a self-extracting executable
Dell_Server_Management_Pack_Suite_v4.1_A00.exe file. You can download the
executable from the Dell Support website at support.dell.com.

What is New in Dell Server Management Pack
Suite Version 4.1
Table 1-1. New Features and Functionalities
New Feature

Functionality

Discovery and
monitoring of server
network interface cards

Supports:
• In-band discovery and monitoring of Physical and
Teamed network interfaces for Broadcom and Intel
network interface cards (NICs).
• Display of enriched properties and attributes of network
interface cards on systems running Server Administrator
versions 6.2.0.1 - 6.4.
• Performance graphs for physical and teamed network
interfaces for Server Administrator version 6.2.0.1 and
above.
• Linkup and linkdown alerts in Network Interfaces Alerts
view.
• Correlation of physical and teamed network interfaces
for Server Administrator version 6.2.0.1 and above in the
Dell Modular Systems and Dell Monolithic Systems
Diagram Views.

Discovery and
monitoring of
iDRAC vFlash Cards

8

Introduction

Supports in-band discovery and monitoring of
iDRAC vFlash card and iDRAC network interface
under Dell systems.

book.book Page 9 Wednesday, December 8, 2010 7:33 PM

Table 1-1.

New Features and Functionalities (continued)

New Feature

Functionality

Discovery and
monitoring – Chassis
Management

Supports:
• Discovery of server modules and chassis slot summary
for CMC and DRAC/MC Chassis.
• Correlation of Dell Servers with Server Modules of CMC
and DRAC/MC Chassis in the Chassis Management
Controller Diagram View.

Additional Traps

Supports:
• All new traps introduced in Server Administrator
versions 6.2.0.1 - 6.4.
• Platform Event Traps (PET) for DRAC and iDRAC.

Remote Desktop Launch Supports launching of remote desktop for discovered Dell
systems from the Operations Manager Console

Key Features of Dell Server Management
Pack Suite
Dell Server Management Pack Suite v4.1provides these features for
management of Dell Windows systems and out-of-band Dell devices:
Table 1-2.

Features and Functionalities

Feature

Functionality

In-band Discovery and
Monitoring - Dell Systems

Supports in-band discovery and monitoring of:
• Dell PowerEdge and PowerVault Monolithic and
Modular systems running the supported Windows
operating system.
• Dell Remote Access Controllers (DRAC),
iDRAC and IPMI devices through in-band.

Introduction

9

book.book Page 10 Wednesday, December 8, 2010 7:33 PM

Table 1-2. Features and Functionalities (continued)
Feature

Functionality

Discovery and Monitoring Chassis Management

Supports:
• Out-of-band discovery and monitoring of Dell
Chassis Management Controllers (CMC) and
DRAC/ Modular Chassis (DRAC/MC) devices.
• Supports discovery of server modules and chassis
slot summary for CMC and DRAC/MC Chassis.
• Correlation of Dell Servers with Server Modules of
CMC and DRAC/MC Chassis.

Out-of-Band Discovery and
Monitoring - Dell Remote
Access Controllers (DRAC)

Supports:
• Out-of-band discovery and monitoring of Dell
Remote Access Controllers (DRAC) 4, DRAC 5,
and integrated DRAC.
• Additional Platform Event Traps (PET) for DRAC
and iDRAC.

Performance Monitoring

For Dell systems, supports:
• Power, temperature and network interface
statistics using Performance and Power
Monitoring Views.
• Performance graphs for physical and teamed
network interfaces for Server Administrator
version 6.2.0.1 and above.

Advanced Monitoring

• Provides flexibility in choosing the level of
instrumentation for Dell systems based on
scalability requirements.
• Detailed monitoring using Server Administrator
by enabling Informational Alerts.

10

Introduction

book.book Page 11 Wednesday, December 8, 2010 7:33 PM

Table 1-2.

Features and Functionalities (continued)

Feature

Functionality

Launching Dell Tools from
Operations Console

Supports:
• Launching Server Administrator Console
• Launching Dell Remote Access Console
• Launching Dell CMC Console
• Launching Dell Modular Chassis Remote Access
Console
• Launching Remote Desktop Console.

About Dell Server Management Pack Suite v4.1
Table below describes the management packs and utilities, and their
dependencies with each other:
Table 1-3.

Management Pack Functionality and Dependencies

Management
Pack/Utility

Description

Dependency

Base Folder Utility

Management Pack for defining the None
Dell Hardware Group and Dell
folder in the Monitoring pane of
the Operations Console.

Scalable Server MP

Management Pack for
instrumenting supported Dell
PowerEdge and PowerVault upto
component groups level.

Base Folder Utility 4.0

Detailed Server MP

Management Pack for
instrumenting supported Dell
PowerEdge and PowerVault upto
component level.

Base Folder Utility 4.0
Scalable Server MP 4.1

NOTE: Use this MP when you are
managing less than 300 nodes

Introduction

11

book.book Page 12 Wednesday, December 8, 2010 7:33 PM

Table 1-3. Management Pack Functionality and Dependencies (continued)
Management
Pack/Utility

Description

Informational-alertsOn Override Utility

Utility for detailed monitoring
Base Folder Utility 4.0
capability, by enabling Dell OMSA Scalable Server MP 4.1
Informational Alerts defined in
Scalable Server MP.

CMC MP

Management Pack for discovering
and monitoring CMC and
DRAC/MC Chassis.

Base Folder Utility 4.0

DRAC MP

Management Pack for discovering
and monitoring Dell Remote
Access Cards - DRAC4, DRAC5,
iDRAC Modular and iDRAC
Monolithic.

Base Folder Utility 4.0

Chassis Modular Server Management Pack for correlating
Correlation Utility
Dell Modular systems with CMC
and DRAC/MC Server Modules.

Base Folder Utility 4.0

This utility is supported only on
SCOM 2007 R2

Dependency

Scalable Server MP 4.1
CMC MP 4.1

NOTE: For correlation feature to

work, you must configure Run As
Accounts and enable CMC Slot
Discovery and/or DRACMC Slot
Discovery. For more information,
see Chassis Modular Server
Correlation Requirement.

NOTE: Import all dependencies first before importing the Management Pack. Delete the
Management Pack first before deleting the dependencies.

Comparison of Scalable Management Pack and Detailed Management Pack

Table 1-4 helps you understand the environment in which you can use
Scalable Management Pack (Scalable MP) and Detailed Management Pack
(Detailed MP) optimally.

12

Introduction

book.book Page 13 Wednesday, December 8, 2010 7:33 PM

Table 1-4.

Scalable Management Pack vs Detailed Management Pack

Property

Scalable Management
Pack

Detailed Management Pack

Component
Hierarchy

Scalable MP shows details
upto the component
groups and the presence
of iDRAC.

Detailed MP shows details upto
component level. Detailed MP
provides an additional level of
information about Memory,
Processors, Network Interfaces,
Storage Controllers, Disks and
Volumes, and so on. Additionally,
BIOS information is also shown

Scalability

You can use the Scalable
MP to monitor optimal
hardware inventory and
can scale above 300 servers
per management server

You can use the Detailed MP to
monitor detailed inventory and can
scale upto 300 servers per
management station

Reports

Only OpenManage
Windows Event log report
is available with this
Management Pack.

BIOS configuration, Firmware and
Driver version, and RAID
configuration reports are available
with this Management Pack.

Supported Dell Devices
The following Dell devices are supported for Dell Server Management Pack
Suite v4.1:
•

Dell PowerEdge systems - complete support for systems ranging from x8xx
to xx1x (both inclusive).

•

Dell PowerVault systems - complete support for systems ranging from x8xx
to xx1x (both inclusive).
NOTE: Both PowerEdge and PowerVault systems are supported with Detailed
Server Management Pack and Scalable Server Management Pack. The
updated list of supported platforms is available on the Dell Support website at
support.dell.com.

•

DRAC 4, DRAC 5, iDRAC 6 with DRAC Management Pack

•

CMC and DRAC/MC with CMC Management Pack.

For more information, see Feature Support Matrix.

Introduction

13

book.book Page 14 Wednesday, December 8, 2010 7:33 PM

Supported Operating Systems
Table below lists the Operating Systems supported on the management
server:
Table 1-5. Operating Systems Supported on the Management Server
Windows Version

Standard
Edition

Enterprise
Edition

Datacenter
Edition

Windows Server 2003 SP2

x86 and x64

x86 and x64

x86 and x64

Windows Server 2003 R2 SP2

x86 and x64

x86 and x64

x86 and x64

Windows Server 2008

x86 and x64

x86 and x64

x86 and x64

Windows Server 2008 SP2

x86 and x64

x86 and x64

x86 and x64

Windows Server 2008 R2

x64

x64

x64

The operating systems supported on the managed nodes are:

14

•

Windows Server 2003 SP2, x86 , x64 (Standard, Enterprise and
Datacenter Edition)

•

Windows Server 2003 SP2, x86, x64 (Standard, Enterprise and
Datacenter Edition)

•

Windows Server 2003 R2 SP2, x86, x64(Standard, Enterprise and
Datacenter Edition)

•

Windows Storage Server 2003 R2 SP2 x64

•

Windows Server 2003 Unified Data Storage x64

•

Windows Server 2008, x86, x64 (Standard, Enterprise and
Datacenter Edition)

•

Windows Server 2008 SP2, x86,x64 (Standard, Enterprise,
Datacenter Edition)

•

Windows Server 2008 R2, x64 (Standard, Enterprise and
Datacenter Edition)

•

Windows Server 2008 Small Business Server (Standard and
Premium Edition)

•

Windows Server 2008 Essential Business Server (Standard and
Premium Edition

Introduction

book.book Page 15 Wednesday, December 8, 2010 7:33 PM

•

Windows Unified Data Storage Server 2008 (Workgroup, Standard and
Premium Edition)

•

Windows Storage Server 2008 (Standard and Enterprise Edition)

•

Windows Server 2008 Unified Data Storage Server,

•

Windows Server 2008 HPC Edition

•

Microsoft Hyper-V Server 2008 x64

•

Windows Server 2008 Unified Data Storage Server x64
NOTE: For Windows Server 2008 operating systems, both SP1 and SP2 versions are
supported.

For the list of supported operating systems for the management server for
SCOM/SCE, see the Microsoft website at
http://technet.microsoft.com/hi-in/library/bb309428(en-us).aspx

Supported Firmware Versions
Table below lists the supported firmware versions for DRAC and CMC
devices.
Table 1-6.

Supported Firmware Versions for DRAC and CMC Devices

DRAC

CMC and DRAC/MC

iDRAC6 Modular: versions 2.3 and 3.0

CMC: versions 2.1 and above

iDRAC6 Monolithic: versions 1.5
and 1.54

DRAC/MC : versions 1.5 and above

xx0x iDRAC: versions 1.4 and 1.52
DRAC 5: versions 1.5 and 1.51
DRAC 4: versions 1.71 and 1.75

Introduction

15

book.book Page 16 Wednesday, December 8, 2010 7:33 PM

16

Introduction

book.book Page 17 Wednesday, December 8, 2010 7:33 PM

2

Getting Started
Management Server (MS) Requirements
Software Requirements
Table below lists the software requirements in the MS.
Table 2-1.

Pre-requisites for Software

Software

Purpose

OpenManage Server Administrator
(Server Administrator)

To discover and manage Dell systems, which host the
management server, discover Chassis Slot Summary
and Server Modules for CMC and DRAC/MC Chassis.

OR
DRAC Tools

To discover Chassis Slot Summary and Server Modules
for CMC and DRAC/MC Chassis.

BMC Management Utility version 2.0

To run the Remote Power Control tasks or the LED
Identification Control tasks on Dell-managed systems.

NOTE: The BMC Management Utility, OpenManage Server Administrator (Server
Administrator) and DRAC tools are available on the Dell Systems Management Tools
and Documentation media, or can be downloaded from support.dell.com.
NOTE: To discover managed systems with IPv6 attributes, you must enable and
configure IPv6 in the management server.
Table 2-2.

Feature Support Matrix

MS Configuration

8G

8G

9G, 10G, 11G 9G, 10G, 11G

Software

OMSA Drac Tools OMSA

Drac Tools

MS Discovered as Dell Server
CMC/DRAC MC Discovery
CMC and DRAC/MC Slot Discovery
Chassis Blade Correlation

Getting Started

17

book.book Page 18 Wednesday, December 8, 2010 7:33 PM

The Management Server Action Account needs the following additional
privileges on Dell systems for the features listed below.
Table 2-3. Management Server Action Account Privileges
Feature

User Privilege

Dell Monolithic server in-Band DRAC Admin or Power user
discovery and the corresponding DRAC
Console launch
Clear ESM Log

Admin or Power user
Alternatively, if the Management Server
Action Account has normal user privileges,
operators can, instead of selecting Use the
predefined Run as Account, enter task
credentials with Power User (or higher)
privileges to run the Clear ESM Logs task.

Discovery Requirements
•

For discovery of Windows systems on your network, perform Windows
Computers discovery.

•

For discovery of DRAC 4, DRAC 5, iDRAC 6, DRAC/MC, and CMC
out-of-band, perform network device discovery.

Security Configuration
Applicable to — Dell CMC MP
To discover Chassis Slot Summary and Server Modules for CMC and
DRAC/MC Chassis, you need to configure the applicable Run As Accounts and
link them to the Dell CMC Login Account or DRAC/MC Login Account Run
As Profiles. For more information, see Configuring the Dell Chassis
Management Controller Management Pack for Discovering Server Modules and
Chassis Slot Summary

18

Getting Started

book.book Page 19 Wednesday, December 8, 2010 7:33 PM

Chassis Modular Server Correlation Requirement
In a distributed SCOM environment where you have a
Multiple Management Server — Single Management Group scenario,
you must enable server proxy on the management server where you
discover and monitor the CMC and/or DRAC/MC chassis.
To enable the proxy agent:
1 In the SCOM console, click Administration.
2 In the Administration pane, click Management Servers.
3 Select the management server where you have discovered CMC and/or
DRAC/MC devices.
4 Right-click and then select Properties.
5 In the Management Server Properties dialog box, click the Security tab.
6 Select the check box to allow the server to act as a proxy and discover
managed objects on other computers.
7 Click OK.
NOTE: The Chassis Modular Server Correlation feature is available only on SCOM
2007 R2. You must enable CMC Slot Discovery and DRAC/MC Slot Discovery for the
correlation feature to work.

Managed System Requirements
Dell System Requirements
The requirements for managed systems are:
•

Install Server Administrator (including the Server Administrator Storage
Management Service.)

Getting Started

19

book.book Page 20 Wednesday, December 8, 2010 7:33 PM

Table 2-4 lists the Server MP features and the corresponding supported
OMSA versions.
Table 2-4.

Server Administrator Version and Supported Feature

Server Administrator Version

5.5 6.1 6.2

6.2.0.1 6.3

6.4

Discovery, inventory and monitoring of
Dell Windows servers
Basic network interface attributes
Enriched network interface attributes
Monitoring iDRAC

(*)

(*)

(*): iDRAC firmware version >=1.54

NOTE: If a system has Server Administrator version lesser than 5.5, it is grouped
under Unmanaged and monitoring is disabled.
NOTE: If you want to upgrade or uninstall Server Administrator on the managed
system, the Alerts View of the managed system may display the following error:
Script or Executable failed to run. If managed system is not
a management server, then switch the system to the Maintenance Mode till the
upgrade/uninstall completes. If the managed system is the management server, you
may manually close the alerts after the upgrade/uninstall is complete.
NOTE: In-Band discovery of iDRAC takes place when the iDRAC firmware version
is greater than or equal to 1.54 and OMSA version is greater than or equal to 6.3.
NOTE: Enable and run the WMI service.

20

•

Install the DRAC agent using the Dell Systems Management Tools and
Documentation media, if Dell Remote Access Controller (DRAC) is
installed on your Dell system.

•

Configure a valid IP address for your BMC and ensure network
connectivity for Advanced power control and LED identification tasks
to work.

Getting Started

book.book Page 21 Wednesday, December 8, 2010 7:33 PM

Configuring Management Server Action Account With
Normal User Privilege
To configure the management server action account:
1 Install SCOM 2007 SP1/R2 and System Center Essentials 2007 SP1/2010
on the management server, with Management Server Action Account as a
Domain user (non Domain Administrator.)
2 Install Operations Manager Agent on the managed system (Auto Agent
Push/ Manual Install).
3 Add the Management Server Action Account (as described in step1 Domain User) as part of the local admin group for Agent install to work.
4 Initiate discovery and monitoring of managed system and demote the
Management Server Action Account from the Local Admin group. Reboot
to make sure that the user is not an administrator/power user.
5 Import the Dell Management Pack on the management server.
The management pack rediscovers the managed systems depending on the
discovery cycle time.

Dell CMC/DRAC MC Requirements
Enable RACADM on CMC/DRAC MC chassis for slot discovery and
correlation to work. For more information, see the Command Line Reference
Guide for iDRAC6 and CMC available at support.dell.com/manuals.

Installing the Dell Server Management Pack
Suite v4.1
Before importing any management pack, import the dependent management
packs first. For MP dependencies, see Table 1-3.

Pre-import Tasks
NOTE: If Dell Server Management Packs 3.x are already present in SCOM,
delete them before you perform the steps below.
NOTE: If Dell Server Management Packs 4.0 are already present in SCOM, you do
not need to delete the Management Packs. You can directly upgrade the
management packs to version 4.1 if you follow the steps given below.

Getting Started

21

book.book Page 22 Wednesday, December 8, 2010 7:33 PM

To import the management packs or utilities, use the SCOM Import
Management Pack wizard:
1 Download the management packs or utilities from the Dell Support
website at support.dell.com.
2 Copy the downloaded file,
Dell_Server_Management_Pack_Suite_v4.1_A00.exe to a temporary
folder on your local system. For example, C:\Temp.
3 Run the Dell_Server_Management_Pack_Suite_v4.1_A00.exe and extract
the management packs or utilities. By default, the files are extracted to
C:\Dell Management Packs\Server Mgmt Suite\4.1.

Importing the Management Packs
To import the management packs:
1 Launch System Center Operations Manager Operations Console or
System Center Essentials Console.
2 From the navigation pane, click Administration.
3 Expand Administration, right-click Management Packs, and select Import
Management Packs.
4 Click Add. Select the Add from disk option.
5 Type or browse to the location of the Management Pack/utility files where
you extracted the Dell Server Management Pack Suite 4.1. If you had
chosen to extract the files in the default directory, then the management
packs are available under C:\Dell Management Packs\Server Mgmt
Suite\4.1.
6 Select the Management Pack/utility you want to import, and click Open.
The Import Management Packs screen appears with the selected
Management Packs/utilities displayed in the Import List.
NOTE: If any of the management packs of Dell Server Management Pack
Suite v4.0, then you must upgrade them in the same import session.
7 Click Install.

22

Getting Started

book.book Page 23 Wednesday, December 8, 2010 7:33 PM

Post-Import Tasks for the Dell Server
Management Pack Suite v4.1
You must perform the following post-import tasks after you import the
management packs:
1 Configure CMC MP 4.1 for discovering Chassis Slots Summary and Server
Modules. For more information, see Configuring the Dell Chassis
Management Controller Management Pack for Discovering Server
Modules and Chassis Slot Summary.
2 Create Advanced Power Control and LED Identification tasks. For more
information, see Creating Advanced Power Control and LED
Identification Tasks.

Configuring the Dell Chassis Management Controller Management Pack
for Discovering Server Modules and Chassis Slot Summary
Create Run As Profiles and Run As Accounts to select users with privileges
that are needed to discover CMC and DRAC/MC server modules and chassis
slot summary.
1 Create a Simple Run As Account that has privileges to connect to the
CMC and/or DRAC/MC chassis. You can also create a Simple Run As
Account with Active Directory (AD) user credentials when the CMC
and/or DRAC/MC Chassis is configured to work with AD. You can also use
Basic or Digest Run As Account types for configuring the user credentials.
2 Associate the CMC Chassis and DRAC/MC Chassis Run As accounts
with the Dell CMC Login Account and Dell DRAC/MC Login Account
Run As Profile included in the Dell CMC MP4.1. Target the configuration
with respect to the Dell CMC or Dell DRAC/MC class respectively. For
SCOM 2007 R2/SCE 2010, you can select the More Secure option in Run
As Account configuration, so that you can selectively distribute the
configuration to specific management servers.

Getting Started

23

book.book Page 24 Wednesday, December 8, 2010 7:33 PM

3 To enable server module and chassis slot summary discovery for CMC,
enable the Dell CMC Slot Discovery rule. It is disabled by default.
4 To enable server module and free slot discovery for DRAC/MC, enable the
Dell DRAC/MC Slot Discovery rule.
NOTE: After the slot discovery, if you remove the link between RunAsAccount
with RunAsProfile, or disable the slot-discovery workflow, the discovered
slots remain with old data.

Creating Advanced Power Control and LED Identification Tasks
Advanced power Control and LED Identification Tasks use the default
BMC credentials, operating system and BMU install path (C:\Program
Files\Dell\SysMgt\bmc), that cannot be modified.
If your systems deviate from these, install BMU 2.0 or later on the
management server and create new console tasks in the Authoring pane
targeted on BMC for Dell Server.
CAUTION: The below steps require you to create a task and give the password

in plaintext. If BMC is not installed on the box, the SCOM Console may display
an error that displays the entire command in a dialog box, and reveals the
password. If you export the created override management pack containing this
task to a disk, you can open the exported management pack in a common text
editor or SCOM Authoring Console and the view the password in plain text.
Create a new task only if absolutely required and consider the above security
aspects before you proceed.

To create a new task:
1 In the Authoring pane, right-click Tasks under Management Pack Objects,
and select Create new task.
2 In the Task Type screen, select Command line under Console Tasks.
3 Select the destination management pack and click Next.
4 Type Task name, Description, and select Dell Windows Server as the
Task Target and click Next.
The Command Line screen appears.
5 Type the path of the application ipmitool.exe (the path where BMU was
installed on the management server) in the Application field. For
example, C:\Program
Files\Dell\SysMgt\bmc\ipmitool.exe (default BMU Path
24

Getting Started

book.book Page 25 Wednesday, December 8, 2010 7:33 PM

may differ based on your operating system language.) For the two LED
identification tasks, the application path is C:\Program
Files\Dell\SysMgt\bmc\ipmish.exe (default BMU Path may
differ based on your operating system language.)
6 For power control tasks, in the Parameters field, enter the command line
parameters in the following format:
•

Type -I lan -H and then choose the Remote Access IP with IPMI
capability from the drop-down menu.

•

Type -U  -P  -k 


•

Replace  with one of the following options:
•

power status (for Check Power Status task)

•

power on (for Power On task)

•

power soft (for Power Off Gracefully task)

•

power off (for Forced Power Off task)

•

power cycle (for Power Cycle task)

•

power reset (for Power Reset task)

•

identify on (for LED Identification On task)

•

identify off (for LED Identification Off task)

A sample command line parameter entry:
-I lan -H $Target/Property[Type=
"Dell.WindowsServer.Server"]/RemoteAccessIP$ -U
root -P  -k  power status
7 For LED on or off tasks, enter the command line parameters in
following format:
•

Type -ip and choose the Remote Access IP with IPMI
capability from drop-down menu.

•

Type -u  -p  -k 
.

8 Click Create to create the task and repeat this procedure for each new
BMC task.

Getting Started

25

book.book Page 26 Wednesday, December 8, 2010 7:33 PM

Upgrading From the Previous Management Packs
Upgrade happens only when you import the upgraded management packs to
the Operations Console. Follow the steps provided in Installing the Dell
Server Management Pack Suite v4.1 to upgrade the new management packs.
This section also includes certain Post Upgrade Tasks, that you need to
perform.

From Dell Server Management Pack Suite v4.0
You can upgrade from Dell Server Management Pack Suite v4.0 to Dell Server
Management Pack Suite v4.1.
NOTE: If any of the management packs of Dell Server Management Pack Suite v4.0
are present on the Management Server, then you must upgrade them to v4.1 in the
same import session.

Post Upgrade Tasks
If you upgrade from Dell Server Management Pack Suite v4.0 to Dell Server
Management Pack Suite v4.1, the Servers state view does not display the
Network Interfaces Group, and iDRAC columns. To see these columns you
must personalize the view and add the columns.
To personalize the view:
1 On the Operations Console, select Servers State view and right-click on
the Servers pane.
2 Select Personalize View from the menu. The Personalize View screen is
displayed.
3 Select Network Interfaces Group, and iDRAC.
4 Click the Up arrow to move the order of the columns so that they are
displayed after the Name column.
5 Close the Personalize View screen.

26

Getting Started

book.book Page 27 Wednesday, December 8, 2010 7:33 PM

From Dell Server Management Pack 3.x
You cannot upgrade from Dell Server Management Pack 3.x to Dell Server
Management Pack Suite 4.1. You must delete the corresponding previous
version of Dell Server MP and then install Dell Server Management Pack
Suite v4.1 on Systems Center Operations Manager. For information on the
steps to import Dell Server Management Pack Suite v4.1 see Installing the
Dell Server Management Pack Suite v4.1.
NOTE: Ensure you delete Dell Server Management Pack 3.x
(Dell.Connections.001.mp) prior to importing any of the Management Packs that are
a part of the Dell Server Management Pack Suite v4.1.
CAUTION: If you delete the Dell Management Packs 3.x, you may loose all the
monitoring data you have collected so far from the Operations Database.

Uninstalling the Dell Server Management Pack
Suite v4.1
Before you uninstall the management packs, you must first delete the
dependent management packs and overrides if any and then delete the
specific management packs. For more information on dependencies, see
Table 1-3.

Deleting the Management Packs
To delete any of the Management Packs or utilities:
1 Select Administration Management Packs in the Systems Center
Operations Manager 2007 Operations Console.
2 Select the Dell Management Pack/utility you want to delete from the
Management Packs pane.
3 Right-click the selected Dell Management Pack/utility and click Delete.
After deleting a Management Pack/utility, Dell recommends closing and
reopening the SCOM Console.
NOTE: Deleting any of the Management Packs may affect the scope of
some user roles.

Getting Started

27

book.book Page 28 Wednesday, December 8, 2010 7:33 PM

Before deleting the Dell CMC Management Pack 4.1
Dell CMC management pack includes two Run As Profiles for CMC and
DRAC/MC respectively. All Run As Accounts associations that you create get
added to the Microsoft.SystemCenter.SecureReferenceOverride
management pack. Deleting the CMC management pack with similar Run As
Account association having dependencies with
Microsoft.SystemCenter.SecureReferenceOverride, would result in conflicts.
To delete CMC management pack:
1 Launch System Center Operations Manager Operations Console or
System Center Essentials Console.
2 From the navigation pane, click Administration.
3 Expand Administration, right click Management Packs
4 Select Microsoft.SystemCenter.SecureReferenceOverride MP, click Export
and save it as a local file.
5 Delete the Microsoft.SystemCenter.SecureReferenceOverride MP.
6 Edit the saved MP in the SCOM Authoring Console by deleting the
following overrides and references:
–

Navigate to Health Model and select Overrides.

–

Delete all overrides with Dell.ModularChassis.CMC or
Dell.ModularChassis.DRACMC references.

–

Open the File menu, select Management Pack Properties, to launch
the Microsoft.SystemCenter.SecureReferenceOverride Properties
screen.

–

Click the References Tab, and delete the Dell.OutOfBand.CMC
reference.

–

Open File menu and select Save.

7 Re-import the edited Microsoft.SC.SecureReferenceOverride MP.

28

Getting Started

book.book Page 29 Wednesday, December 8, 2010 7:33 PM

Access Privileges
Operations Console access privileges are handled internally by SCOM.
This can be setup using the User Roles option under Administration  Security
feature on the SCOM console. The profile assigned to you determines what
actions you can perform. For more information on security considerations, see
the Microsoft Operations Manager 2007 SP1/ Microsoft Systems Centre
Essentials SP1 R2/Microsoft Systems Center Essentials 2010 online help
available with System Center Essentials 2010.

Getting Started

29

book.book Page 30 Wednesday, December 8, 2010 7:33 PM

30

Getting Started

book.book Page 31 Wednesday, December 8, 2010 7:33 PM

3

Understanding Dell Server
Management Pack Suite Operations
Overview
This chapter describes the various operations that you can perform on
Microsoft Systems Center Operations Manager (SCOM) or Systems Center
Essentials (SCE) using the Dell Server Management Pack Suite version 4.1.
The Dell Server Management Pack Suite version 4.1 enables you to:
1 Discover and group the Windows servers, Dell Modular Chassis, Dell
Remote Access Controllers (DRAC), Chassis Management Controllers
(CMC), and integrated DRAC (iDRAC). For more information, see
Discovery and Grouping.
2 Monitor the discovered Dell systems and network devices. For more
information, see Monitoring.
3 Perform various tasks on the discovered Dell systems and network devices.
For more information, see Tasks.
4 Create pre-canned reports for OpenManage Windows Event Log, Dell Server
BIOS, Firmware, and RAID configuration. For more information, see Reports.
5 Customize discovery, monitoring, and event processing of the discovered
Dell systems and devices. For more information, see Customizing the Dell
Server Management Pack Suite.

Web Console
The Web console server enables you to monitor and manage your Dell
devices with Dell Server Management Pack Suite using a browser instead of
the Operations Console. You can use the Web console server without
installing the Operations console.
Using the Web console has the following limitations:
•

Provides only the Monitoring feature for all Management Packs

•

Administration, Authoring, and Reporting are not available
Understanding Dell Server Management Pack Suite Operations

31

book.book Page 32 Wednesday, December 8, 2010 7:33 PM

•

Personalize view is not available

•

Only first 200 alerts are displayed in the Alert view

•

For the Server Management Pack:

•

•

Displays only Clear ESM Log task

•

Information alerts are suppressed even after importing
Information-On override utility

For the DRAC and CMC Management Packs:
•

Console launch tasks are not available

Discovery and Grouping
Dell Windows systems are discovered through the SCOM Agent
Management infrastructure. Dell systems that do not have
Dell OpenManage Server Administrator installed, or have Server
Administrator earlier than 5.5 are grouped as Dell Unmanaged.
To discover Dell devices, the devices must appear in the Agent Managed
view under the Administration section of the Operations Console.

Discovering a Dell System
To discover a Dell system:
1 Log on to the system with an account that has the SCOM Administrators
role, for the SCOM Management Group.
2 In the Operations Console, click Administration.
3 At the bottom of the navigation pane, click Discovery Wizard.
The Computer and Device Management Wizard is launched.

32

Understanding Dell Server Management Pack Suite Operations

book.book Page 33 Wednesday, December 8, 2010 7:33 PM

4 Select Windows Computers and click Next.
5 To discover Dell Modular and Monolithic systems, select Automatic
Computer Discovery and click Next.
a

Provide user account details on the Administrator Account screen and
click Discover. The Discovery Progress page appears.

b

On the Select Objects to Manage page, select the devices you want to
manage and click Next.

c

On the Summary screen, specify the path for Agent Installation
Directory, specify the credentials for Agent Action Account,
and click Finish.

NOTE: Dell windows systems that do not have the instrumentation component
running and Server Administrator lesser than 5.5 installed are grouped under Dell
Unmanaged systems.

Discovering DRAC and CMC Devices
To discover Dell DRAC and CMC devices:
1 Follow steps 1 to 3 as described under Discovering a Dell System.
2 Select Network Devices in the Computer and Device Management
Wizard screen, and click Next.
3 Type the Start and End of the IP address range that you want to scan,
type the SNMP Community, and select the SNMP version.
4 Click Discover. The Discovery Progress page appears.
5 On the Select Objects to Manage page, select the devices you want to
manage and click Next.
6 Click Finish.
NOTE: You can override the discovery intervals from the Authoring pane of the
Operations console. To override the discovery intervals for iDRAC 6 modular, modify
the discovery interval period for both the discoveries - DRAC5/iDRAC Discovery
and Dell Integrated Remote Access (Modular) Discovery.

Understanding Dell Server Management Pack Suite Operations

33

book.book Page 34 Wednesday, December 8, 2010 7:33 PM

Dell Hardware Discovery and Grouping
Table 3-1 lists the details of the hardware discovery and grouping by the
Dell Server Management Pack suite.
Table 3-1. Dell Hardware Discovery and Grouping
Classification

Group Name on SCOM Console Hardware Type

Windows Servers

• Dell Monolithic Servers.
• Dell Modular Servers.

Dell Modular
Chassis Remote
Access

Dell Chassis Management
Controllers (parent group):
• Dell Modular Chassis
Remote Access (child
group).

Dell PowerEdge and
PowerVault systems running
OpenManage Server
Administrator (version 5.5 and
above).
CMC, DRAC/MC instances
on the network, chassis slot
summary and server modules
for CMC and DRAC/MC.

• Dell CMCs (child group).
Dell Remote Access
Controllers

Dell Remote Access
Controllers (parent group):
• Dell Remote Access 4
(child group).

DRAC 4, DRAC 5, iDRAC
modular, and iDRAC 6
monolithic instances.

• Dell Remote Access 5
(child group).
• Dell Integrated Remote
Access Modular (child
group).
• Dell Integrated Remote
Access Monolithic (child
group).

NOTE: Dell Remote Access Controller Management Pack does not support the
discovery of xx0x iDRAC modular controller out-of-band systems due to iDRAC hardware
limitation. To manage iDRAC xx0x modular controller, use Scalable Server Management
Pack where xx0x iDRAC would be discovered in-band as a part of the Server Inventory.

34

Understanding Dell Server Management Pack Suite Operations

book.book Page 35 Wednesday, December 8, 2010 7:33 PM

Objects Discovered by Dell Server Management Pack
Table 3-2. Dell Object Discoveries
Discovery Object

Description

Dell Server Detailed BIOS Discovery

Discovers BIOS object for each Dell System.

Dell Server Discovery

Classifies your Dell System and populates the
basic attributes.

Dell Server Hardware Components
Discovery

Discovers hardware components at a group
level (Sensors, Processor, Memory, and Power
Supplies) and attributes (such as launch
points for OpenManage Server Administrator,
DRAC, Remote Access IP with IPMI
capability, and so on) for your Dell system.

Dell OpenManage Software Services
Discovery

Discovers the objects for Dell OpenManage
Server Administrator Windows services and
the WMI.

Dell Server Detailed Memory
Discovery

Discovers memory instances for your Dell
system.

Dell Server Detailed Power Supply
Discovery

Discovers power supply instances for your
Dell system.

Dell Server Detailed Processor
Discovery

Discovers processor instances for your Dell
system.

Dell Server Detailed Storage
Discovery

Discovers the complete storage hierarchy for
your Dell system.

Dell Server Network Interface
Discovery

Discovers the network interface instances of
your Dell system.

Dell Windows Server Detailed
Discovers the physical and teamed network
Network Interfaces Discovery Module interface instances of your Dell system.
Dell Windows Server Network
Interfaces Group Discovery Module

Discovers the Network Interfaces Group.

Dell CMC Discovery

Discovers all supported Dell CMCs.

Dell CMC Slot Discovery

Discovers all supported Dell CMC server
modules and chassis slot summary.

Dell CMC Chassis to Modular Server Discovers the correlation between the CMC
Correlation Discovery
Chassis and the Dell modular systems.

Understanding Dell Server Management Pack Suite Operations

35

book.book Page 36 Wednesday, December 8, 2010 7:33 PM

Table 3-2. Dell Object Discoveries (continued)
Discovery Object

Description

Dell DRAC/MC Chassis to Modular
Server Correlation Discovery

Discovers the correlation between
DRAC/MC chassis and Dell modular
systems.

Dell DRAC/MC Discovery

Discovers all supported Dell DRAC/MCs.

Dell DRAC/MC Slot Discovery

Discovers all supported Dell DRAC/MC
server modules and chassis slot summary.

Dell Integrated Remote Access
Modular Group Discovery

Discovers the Dell Integrated Remote Access
Modular Group and populates with Dell
Integrated Remote Access Controllers
(Modular).

Dell Remote Access Group Discovery Discovers the Dell Remote Access Group and
populates with Dell Remote Access
Controllers.
Dell Integrated Remote Access
Monolithic Group Discovery

Discovers the Dell Integrated Remote Access
Monolithic Group and Dell Integrated
Remote Access Controllers (Monolithic).

Dell Remote Access 4 Group
Discovery

Discovers the Dell Remote Access 4 Group
and Dell Remote Access 4 Controllers.

Dell Remote Access 5 Group
Discovery

Discovers the Dell Remote Access 5 Group
with Dell Remote Access 5 Controllers.

Dell Integrated Remote Access
Modular Discovery

Discovers the Chassis Name and Chassis
Service Tag of Dell Integrated Remote Access
Controllers for Modular systems.

DRAC5/iDRAC Discovery

Discovers all supported Dell Remote Access 5
Controllers and Integrated Remote Access
Controllers.

DRAC4 Discovery

Discovers all supported Dell Remote Access 4
Controllers.

Dell Unmanaged Server Group
Discovery

Discovers Dell systems that are not being
monitored either due to the absence of Dell
instrumentation, or has a lower version of
instrumentation than the required version.

36

Understanding Dell Server Management Pack Suite Operations

book.book Page 37 Wednesday, December 8, 2010 7:33 PM

Monitoring
The Dell Server Management Pack Suite v4.1 enables you to monitor the
discovered Dell systems and network devices. The Severity Level Indicators
help you to monitor the health of your Dell devices on the network.
Monitoring of Dell devices includes the following tasks:
•

Process events raised by Dell OpenManage Server Administrator (Server
Administrator) agents running on Dell Modular and Monolithic systems
and display the alerts on the Operations Console

•

Monitor Health of Dell Modular and Monolithic systems and their
components both at regular intervals and on occurrence of events

•

Process SNMP trap and knowledge base for CMC, DRAC/MC, and Dell
Remote Access Controllers

•

Monitor Health of CMC, DRAC/MC, and Dell Remote Access Controllers
- both at regular intervals of six hours and on occurrence of SNMP traps

You can monitor the Dell systems and devices through the various views that
the Dell Server Management Pack Suite provides on the SCOM console. The
different views are:
•

Alerts View

•

Diagram View

•

State View

•

Performance and Power Monitoring Views

Severity Level Indicators

Table 3-3 lists the icons that indicate the severity levels of the status of the
discovered Dell devices on the Operations Console.
Table 3-3. Severity Level Indicators
Icon

Severity Level
Normal/OK. The component is working as expected.
Warning/Noncritical. A probe or other monitoring device has detected
a reading for the component that is above or below the acceptable level.
The component may still be functioning, but it could fail.
The component may also be functioning in an impaired state.
Understanding Dell Server Management Pack Suite Operations

37

book.book Page 38 Wednesday, December 8, 2010 7:33 PM

Table 3-3. Severity Level Indicators (continued)
Icon

Severity Level
Critical/Failure/Error.The component has either failed or failure is
imminent. The component requires immediate attention and may need
to be replaced. Data loss may have occurred.
The health status is not applicable for the specific component.
The service is unavailable.

Alerts View
This view is available for managing hardware and storage events from
Dell Windows systems, Dell CMC and DRAC/MC, Network Interfaces,
and Dell Remote Access devices.
The Dell Server Management Pack Suite displays the following alerts and
traps:
•

Alerts for events received from Dell OpenManage Server Administrator for
Dell PowerEdge and PowerVault systems.

•

Link Up/Link Down alerts for events received from Broadcom and Intel
network interface cards for Dell PowerEdge systems.

•

Informational alerts if you import the
Dell.WindowsServer.InformationalAlertsOn.mp.
Informational alerts are turned off by default. You need to turn them on
after importing Dell.WindowsServer.InformationalAlertsOn.mp.

38

•

SNMP Traps sent by DRAC 4, DRAC 5, iDRAC 6, DRAC/MC, and CMC
devices.

•

Platform Event Traps (PET) for Dell systems.

Understanding Dell Server Management Pack Suite Operations

book.book Page 39 Wednesday, December 8, 2010 7:33 PM

Viewing Alerts on the Operations Console

To view Alerts on the Operations Console:
1 Launch the Operations Console and click Monitoring.
2 Click Dell Alerts Views.
The following individual Alerts Views are displayed:
•

CMC — displays SNMP traps from the discovered CMC devices

•

Network Interface Alerts — displays the Link up and Link down alerts
from the discovered NICs.

•

DRAC/MC — displays events and SNMP traps from the discovered
DRAC/MC devices

•

PET Traps — displays platform event traps from discovered
Dell systems

•

Remote Access — displays SNMP traps from DRAC 4, DRAC 5,
iDRAC 6 devices.

•

Server — displays Server Administrator alerts from Dell systems,
Link up and Link down alerts from the NICs on Dell systems.

3 Select any of the Alerts Views.
The right pane of each of the individual Alerts Views displays alerts that
meet the criteria you specify, such as alert severity, resolution state,
or alerts that are assigned to you.
4 Select an alert to view the details in the Alert Details pane.
When you select an alert listed in any of the Alerts Views, the associated tasks
appear in the Actions pane. For more information on the tasks, see Tasks.
NOTE: The Remote Access view displays DRAC 4, DRAC 5, and iDRAC 6 alerts.

Diagram View
The Diagram view offers a hierarchical and graphical representation of all
Dell Windows systems, Dell CMC and DRAC/MC, and Dell Remote Access
devices that the Dell Server Management Pack Suite manages. The Diagram
view displays realistic icons for the various components modeled by the Dell
Server Management Pack Suite.

Understanding Dell Server Management Pack Suite Operations

39

book.book Page 40 Wednesday, December 8, 2010 7:33 PM

To view the diagrams on the Operations Console:
1 Launch the Operations Console and click Monitoring.
2 In the Monitoring pane on the left side, navigate to the Dell folder to
display the following views:
•

Chassis Management Controllers Group Diagram View

•

Complete Diagram View

•

Dell Modular Systems Diagram View

•

Dell Monolithic Systems Diagram View

•

Remote Access Controllers Group Diagram View

3 Select any of the Diagram Views.
The right pane displays the hierarchical and graphical representation of
the selected Dell device.
4 Select a component in the diagram to view its details in the Detail View
pane.
Complete Diagram View

Figure 3-1 represents the complete diagram view under Dell Hardware group.
Figure 3-1. Dell Complete Diagram View- Detailed Management Pack

40

Understanding Dell Server Management Pack Suite Operations

book.book Page 41 Wednesday, December 8, 2010 7:33 PM

The Complete Diagram View offers a graphical representation of all
Dell devices that SCOM/SCE manages and allows you to expand and verify
the status of individual devices and their components in the diagram. You can
view details for:
•

Modular and Monolithic Systems

•

Chassis Management Controllers and DRAC/MC Devices

•

Remote Access Controllers
NOTE: The Dell Hardware Group is defined in the Base Management Pack.

Modular and Monolithic Systems

The Diagram view under the Monolithic and Modular systems offers the
following details:
•

Physical and teamed network interfaces

•

Memory

•

Power Supply (only monolithic systems)

•

Sensors

•

Processors

•

Dell OpenManage Software services

•

Storage controller

•

BIOS object (only inventory)

•

iDRAC
NOTE: You can launch device/component specific tasks from the Actions pane of
the Operations Console. For more information, see Tasks.

Understanding Dell Server Management Pack Suite Operations

41

book.book Page 42 Wednesday, December 8, 2010 7:33 PM

Dell Modular Systems Diagram View

Figure 3-2 represents diagram view of the Dell Modular systems.
Figure 3-2. Dell Modular Systems Diagram - Detailed Management Pack

The Dell Modular Systems Diagram View offers a graphical representation of
all Dell Modular Systems and allows you to expand and verify the status of
individual devices and their components in the diagram.

42

Understanding Dell Server Management Pack Suite Operations

book.book Page 43 Wednesday, December 8, 2010 7:33 PM

Dell Monolithic Systems Diagram View

Figure 3-3 represents the diagram view of the Dell Monolithic systems.
Figure 3-3. Dell Monolithic Systems Diagram - Detailed Management Pack

The Dell Monolithic Systems Diagram View offers a graphical
representation of all Dell Monolithic Systems and allows you to expand and
verify the status of individual devices and their components in the diagram.

Understanding Dell Server Management Pack Suite Operations

43

book.book Page 44 Wednesday, December 8, 2010 7:33 PM

Dell Server Instance Diagram

Select a Dell system, from the Dell Modular System or Dell Monolithic
System Diagram views, to view the diagram specific to that particular system.
Figure 3-4. Dell Server Instance Diagram - Detailed Management Pack

System-specific diagrams illustrate and indicate the status of the following
components:
•

Memory

•

Power supply (only for Monolithic servers)

•

Processors

•

Sensors

•

OpenManage services

•

Network Interfaces

•

Storage Controllers

•

BIOS Objects

•

iDRAC

The Detailed Management Pack displays memory, processors, and power
supply components in detail.

44

Understanding Dell Server Management Pack Suite Operations

book.book Page 45 Wednesday, December 8, 2010 7:33 PM

Storage Controller Component Hierarchy

Expand the Storage component in any Dell System instance diagram view,
to view the status and health of components like Physical Disks, Connectors,
and Virtual Disks. Each Connector instance contains the Sensors and
Physical Disk components. However, there are no sensors for the backplane.
Network Interfaces Component Hierarchy

The Network Interfaces group is created only when an Intel or Broadcom
network interface card is present on the Dell Windows Server and is enabled.
Network interfaces are grouped under Physical Interfaces and Teamed
Interfaces. If you disable a network interface, it is removed from management
in the next discovery cycle.
A reference relationship is created between a Teamed network interface and
its associated Physical network interfaces. You can view the reference
relationship only when you enable the Enable Correlation attribute of Dell
Windows Server Physical and Teamed Relationship Discovery.
To enable the Enable Correlation attribute:
1 In the Authoring tab, Authoring anagement Pack Objects Object
Discoveries
2 Click Change Scope at the top of the screen.
3 Click View all targets radio button and type Dell at the Look for field.
4 Check Teamed Network Interface instance (Basic) and Teamed Network
Interface instance (Enriched) and click OK.
5 Right-click Dell Windows Server Physical and Teamed Relationship
Discovery Rule Overrides Override the Object Discovery for all
objects of class: Teamed Network Interface instance (Enriched).
In the Override Properties pop-up page, check Enable Correlation and set the
Override Value to True and click OK.
The status roll-up of network interfaces on the Diagram view is displayed only
up to the Network Interfaces group level. For example, if the remaining
components of the Dell system are normal and only one or more of the
network interfaces are critical or noncritical, then the Dell system displays the
Normal icon, and the Network Interfaces group displays the Critical or
Warning icon.

Understanding Dell Server Management Pack Suite Operations

45

book.book Page 46 Wednesday, December 8, 2010 7:33 PM

For the status roll-up to be displayed at the server level, you must enable the
Network Interfaces Group to Dell Server Health Roll up dependency
monitor.
To enable the monitor:
1 Click the Authoring tab on the Operations Console.
2 Click Monitors and on the left pane and select the Network Interfaces
Group monitor on the right pane.
3 Click Entity Health Availability.
4 Right-click on Network Interfaces Group to Dell Server Health Roll up
and select Overrides Enable the Monitor from the menu options.
Figure 3-5. Network Interfaces Diagram View

46

Understanding Dell Server Management Pack Suite Operations

book.book Page 47 Wednesday, December 8, 2010 7:33 PM

Chassis Management Controllers Group Diagram View

Figure 3-6 represents the Chassis Management Controller Group Diagram
view.
Figure 3-6. Chassis Management Controllers Group Diagram

The Chassis Management Controllers Group diagram view offers a graphical
representation of all Dell CMC, DRAC/MC devices, and their inventory.
For CMC discovery, see, Discovering DRAC and CMC Devices. CMCs are
discovered under Modular Chassis.
For discovered CMC and DRAC/MC chassis, you can view the occupied and
free slot summary in the Chassis Slots Summary.
If slot names are modified on CMC and DRAC/MC chassis, they are reflected
in the diagram view.
The Chassis Management Controllers Group diagram also displays the
correlation of Dell servers with the server modules of CMC and DRAC/MC
chassis. The Dell system is visible under the slot in the diagram.

Understanding Dell Server Management Pack Suite Operations

47

book.book Page 48 Wednesday, December 8, 2010 7:33 PM

NOTE: Create RunAsAccount for CMC slots discovery with simple, basic, or digest
authentication only. For more information, see Configuring the Dell Chassis
Management Controller Management Pack for Discovering Server Modules and
Chassis Slot Summary.
NOTE: Only one set of credentials is considered for discovering CMCs in SCOM
SP1 and SCE SP1. SCOM 2007 R2 and SCE 2010 allow greater flexibility where the
credentials can be specified for group or instance level.
NOTE: The iDRAC firmware of the Modular systems should be compatible with the
CMC firmware, failing which, the Service Tag is displayed as "Not Available" and the
Chassis-Blade correlation may not be possible.
CAUTION: The Chassis Modular Server Correlation Utility discovers the
correlation between the Dell CMCs or DRAC/MCs discovered by the CMC
management pack and the Dell modular systems discovered by the Server
management pack. To discover the correlation, the utility queries the Root
Management Server (RMS). When you are monitoring a large number of chassis
and modular systems, the number of queries to the RMS increases and this results
in high CPU utilization on the management server that manages the CMCs or
DRAC/MCs. The CPU utilization comes down after the correlation is complete. This
behaviour occurs in every discovery cycle set in Dell CMC Chassis to Modular
Server Correlation Discovery or the Dell DRAC/MC Chassis to Modular Server
Correlation Discovery.
Remote Access Controllers Group Diagram View

Figure 3-7 represents the Remote Access Controllers Group Diagram
Figure 3-7. Remote Access Controllers Group Diagram

48

Understanding Dell Server Management Pack Suite Operations

book.book Page 49 Wednesday, December 8, 2010 7:33 PM

The Remote Access Controllers Group diagram view offers a graphical
representation of all DRAC 4, DRAC 5, and iDRAC 6 (modular and
monolithic) devices. Select a component in the diagram to view its details in
the Detail View pane.

State View
This view is available for managing Dell Windows systems, Dell CMC and
DRAC/MC, and Dell Remote Access devices. In the Operations Console
Dell State Views displays the status of each Dell device managed by
SCOM 2007 SP1/R2 on your network.
Select the device group for which you want to see the State view. For example,
click Servers to view the status of your Dell Monolithic and Modular systems.
You can view the status of the following groups:
•

CMC

•

Servers

•

DRAC 4

•

DRAC 5

•

DRAC/MC

•

iDRAC

The health of a component is derived by reviewing the unresolved alerts
associated with the component. Table 3-3 explains the various state
components that the Dell Server Management Pack Suite v4.1 uses with their
corresponding severity levels.

Performance and Power Monitoring Views
To view the performance and power monitoring on the Operations Console:
1 Launch the Operations Console and click Monitoring.
2 In the Monitoring pane on the left side, click DellPerformance and
Power Monitoring to display the following views:
•

Ambient Temperature

•

Amperage Per Power supply

•

Energy Consumption

•

Peak Amperage
Understanding Dell Server Management Pack Suite Operations

49

book.book Page 50 Wednesday, December 8, 2010 7:33 PM

•

Peak Power

•

Physical Network Interface

•

Power Consumption (in Watts)

•

Power Consumption (in BTU/hr)

•

Teamed Network Interface
NOTE: Power Monitoring is applicable for specific Dell Systems with Power
Monitoring capability for that particular attribute.
NOTE: Teamed and Physical network interface instances appear only when
detailed MP is present.

3 Select the counters from the individual performance views and select the
time range for which the values are required. The data collected is
represented in a graphical format for each system.
A unit monitor monitors the performance counter over two successive cycles
to check if it exceeds a threshold value. When the condition is breached,
the server changes state and generates an alert. This unit monitor is disabled
by default. You can override (enable and modify) the threshold values from
the Authoring pane of the Operations console, under Monitors for Dell
Windows Server objects.
For more information on performance information collection,
see Performance Collection Rules.

50

Understanding Dell Server Management Pack Suite Operations

book.book Page 51 Wednesday, December 8, 2010 7:33 PM

Tasks
Tasks are available in the Actions pane of the Operations Console. When you
select a device or a component in any of the Dell diagram views, the relevant
tasks appear in the Actions pane.
You can run all the tasks from the Diagram view, State view, or Alert view.
A summary of the Dell Tasks that you can perform using the
Dell Management Packs are explained in Table 3-4:
Table 3-4. Dell Tasks Using the Management Pack for SCOM 2007 SP1/R2
Dell Task

Description

Dell Modular and Monolithic System Tasks
Clear ESM Logs

Backs up the content of the Embedded System
Management (ESM) log and clear the ESM log file
for a selected system.

Launch Server Administrator

Launches the Dell OpenManage Server
Administrator.

Launch Remote Desktop

Launches remote desktop of the selected system.

Check Power Status

Checks the overall power status of the system.

Forced Power Off

Turns off the system's power without shutting down
the operating system.

Launch InBand Dell Remote
Access Console

Launches the DRAC console for the in-band
discovered DRAC.

Power Cycle

Turns off the power, and after a delay, turns it on
again.

Power Off Gracefully

Shuts down the operating system first, then turns
off the system's power.

Power On

Turns on the system power. This option is available
even if the system is on.

Power Reset

Turns off the system's power and turns it on again.

Turn LED Identification On

Turns on the Identify LED of the selected system
for 255 seconds.

Turn LED Identification Off

Turns off the Identify LED of the selected system.

DRAC4/DRAC5/iDRAC Tasks

Understanding Dell Server Management Pack Suite Operations

51

book.book Page 52 Wednesday, December 8, 2010 7:33 PM

Table 3-4. Dell Tasks Using the Management Pack for SCOM 2007 SP1/R2 (continued)
Dell Task

Description

Launch Dell RemoteAccess
Console

Launches the DRAC console for the discovered
DRAC.

Dell CMC, DRAC/MC Tasks
Launch Dell CMC Console

Launches the CMC console.

Launch Dell Modular Chassis
Remote Access Console

Launches the DRAC/MC Console.

Dell Modular and Monolithic Systems Tasks
Clear ESM Logs

The Server Administrator Embedded Server Management (ESM) log,
also referred to as the hardware log, maintains a list of all system events
generated by the hardware, such as error-correcting code (ECC), system reset
and boot, and probe threshold changes. You can refer to this log when
hardware errors appear or when the system is not functioning properly.
To run the Clear ESM Logs task:
1 In the Operations Console, navigate to a Diagram view, State view, or
Alert view.
2 Select the desired Dell system in any of the Diagram or State views or an
alert in the Alerts view.
3 Click Clear ESM Logs under Dell Windows Server Tasks in the Actions
pane. The Run Tasks window appears.
4 Click Run to clear the ESM logs of the device that you selected.
When you run the Clear ESM Logs task, the task execution screen
displays only the result of the task initiation and not the result of the
task execution. For example, the task execution screen may show a
success result even if the ESM logs are not cleared. This means that the
Clear ESM Logs task initiation was successful.

52

Understanding Dell Server Management Pack Suite Operations

book.book Page 53 Wednesday, December 8, 2010 7:33 PM

Launch Server Administrator

To launch Server Administrator from the Operations Console:
1 In the Operations Console, navigate to a Dell Diagram view, State view, or
Alert view.
2 Select the desired Dell system in any of the Diagram or State views or an
alert in the Alerts view.
3 Click Launch Server Administrator under Dell Windows Server Tasks in
the Actions pane.
NOTE: Dell Management Pack Tasks launch the Remote Console in Internet Explorer.
Launch Remote Desktop

To launch Remote Desktop from the Operations Console:
1 In the Operations Console, navigate to a Dell Diagram view, State view, or
Alert view.
2 Select the desired Dell system in any of the Diagram or State views or an
alert in the Alerts view.
3 Click Launch Remote Desktop under Dell Windows Server Tasks in the
Actions pane.
NOTE: Launching remote desktop is possible only if remote desktop is enabled
manually in the managed node.
Check Power Status

You can check the power status and allow power control tasks through the
IPMI shell.
To check the power status of a system:
1 In the Operations Console, navigate to a Dell Diagram view, State view, or
Alert view.
2 Select the desired Dell system in any of the Diagram or State views or an
alert in the Alerts view.
3 In the Actions pane, select Dell Windows Server Tasks  Check Power
Status.

Understanding Dell Server Management Pack Suite Operations

53

book.book Page 54 Wednesday, December 8, 2010 7:33 PM

Power Cycle

You can use this task to turn off the power to the Dell system, and after a
delay, turn it on again.
To run the power cycle:
1 In the Operations Console, navigate to a Dell Diagram view, State view, or
Alert view.
2 Select the desired Dell system in any of the Diagram or State views or an
alert in the Alerts view.
3 In the Actions pane, select Dell Windows Server Tasks Power Cycle.
Force Power Off

You can use this task to power off the system without shutting down the
operating system.
To power off the system:
1 In the Operations Console, navigate to a Dell Diagram view, State view, or
Alert view.
2 Select the desired Dell system in any of the Diagram or State views or an
alert in the Alerts view.
3 In the Actions pane, select Dell Windows Server Tasks Force Power Off.
Power Off Gracefully

You can use this task to shut down the operating system and power off the
system.
To power off the system gracefully
1 In the Operations Console, navigate to a Dell Diagram view, State view, or
Alert view.
2 Select the desired Dell system in any of the Diagram or State views or an
alert in the Alerts view.
3 In the Actions pane, select Dell Windows Server Tasks Power Off
Gracefully.

54

Understanding Dell Server Management Pack Suite Operations

book.book Page 55 Wednesday, December 8, 2010 7:33 PM

Power On

You can use this task to power on the server. This option is available even if
the system power is on.
To power on a system:
1 In the Operations Console, navigate to a Dell Diagram view, State view, or
Alert view.
2 Select the desired Dell system in any of the Diagram or State views or an
alert in the Alerts view.
3 In the Actions pane, select Dell Windows Server Tasks Power On.
Power Reset

You can use this task to turns power off and power on the system.
To reset the power of the system:
1 In the Operations Console, navigate to a Dell Diagram view, State view, or
Alert view.
2 Select the desired Dell system in any of the Diagram or State views or an
alert in the Alerts view.
3 In the Actions pane, select Dell Windows Server TasksPower Reset.
Turn LED Identification Off

You can use this task to turn off the LED identification of the selected
system.
To turn off LED identification:
1 In the Operations Console, navigate to a Dell Diagram view, State view, or
Alert view.
2 Select the desired Dell system in any of the Diagram or State views or an
alert in the Alerts view.
3 In the Actions pane, select Dell Windows Server Tasks Turn LED
Identification Off.
Turn LED Identification On

You can use this task to turn on the LED identification on the system.
To turn on LED identification:
Understanding Dell Server Management Pack Suite Operations

55

book.book Page 56 Wednesday, December 8, 2010 7:33 PM

1 In the Operations Console, navigate to a Dell Diagram view, State view, or
Alert view.
2 Select the desired Dell system in any of the Diagram or State views or an
alert in the Alerts view.
3 In the Actions pane, select Dell Windows Server Tasks Turn LED
Identification On.

Dell Remote Access Controller (DRAC) Tasks
Launch Dell Remote Access Console

You can use this task to launch the Dell Remote Access Console, if the DRAC
is installed on your Dell system.
To launch Dell Modular Chassis Remote Access Console:
1 In the Operations Console, navigate to a Dell Diagram view, State view,
or Alerts view.
2 Select the desired DRAC/iDRAC device in any of the Diagram or State
views or an alert in the Alerts view.
3 In the Actions pane, select SNMP Network Device Tasks Launch Dell
RemoteAccess Console.

Dell Chassis Management Controller (CMC) Tasks
Launch Dell CMC Console

You can use this task to launch the CMC Console.
1 In the Operations Console, navigate to the Dell Diagram view, State view
or Alerts view.
2 Select the CMC device in any of the Diagram or State views or an alert in
the Alerts view.
3 In the Actions pane, select SNMP Network Device Tasks Launch Dell
CMC Console.

56

Understanding Dell Server Management Pack Suite Operations

book.book Page 57 Wednesday, December 8, 2010 7:33 PM

Launch Dell Modular Chassis Remote Access Console

You can use this task to launch the DRAC/MC Console.
1 In the Operations Console, navigate to the Dell Diagram view, State view
or Alerts view.
2 Select the DRAC/MC device in any of the Diagram or State views or an
alert in the Alerts view.
In the Actions pane, select SNMP Network Device Tasks Launch Dell
Modular Chassis Remote Access Console.

Reports
The Reporting feature is available with the Dell Server Management Pack
Suite v4.1. It allows you to create pre-canned reports for OpenManage
Windows Event Log, Dell Server BIOS, Firmware, and RAID configuration.
Dell Server BIOS, Firmware, and RAID Configuration Reports are only
available in Detailed Server Management Pack. You cannot see these reports
if you choose to have only the Scalable Server Management Pack.
To access the Reporting feature perform the following steps:
1 Click Reporting in your Operations Console.
2 Expand Reporting in the navigation pane.
3 Click on Dell Windows Server Scalable Edition for the Windows Event
Log and click on Dell Windows Server Detail Edition for BIOS, firmware,
and RAID reports.
You can also access Reporting from the diagram view by clicking on the server
instance. The option for Dell Reports is located in the Actions pane under
the Dell System instance reports along with the default Microsoft reports.

OpenManage Windows Event Log
To create an OpenManage Windows Event Log:
1 Click on OpenManage Windows Event Log. Click Open in the
Actions pane.
2 Select a time period for which you want the report generated.
3 Click on Add Object or Add Group.

Understanding Dell Server Management Pack Suite Operations

57

book.book Page 58 Wednesday, December 8, 2010 7:33 PM

4 Click Search, to search for an object or group. Choose add (you can
add multiple objects). You can find the object in the selected object pane.
5 Choose the severity of the events whose report you want to generate.
6 Click Run. The OpenManage Windows Event Log report is generated.

BIOS Configuration
NOTE: You can create BMC reports only if BMU is installed on the Management

Server.

To create a report for the BIOS configuration:
1 Click on BIOS Configuration. Click Open in the Actions pane.
2 Select a time period for which you want the report generated.
3 Click on Add Object or Add Group.
4 Click Search, to search for an object or group. Choose add (you can add
multiple objects). You can find the selected object in the selected object pane.
5 Choose the required Properties.
6 Click Run. The BIOS configuration report is generated.

Firmware and Driver Versions
To create a report for Firmware and Driver Versions:
1 Click on Firmware and Driver Versions. Click Open on the Actions pane.
2 Select a time period for which you want the report generated.
3 Click on Add Object or Add Group.
4 Click Search, to search for an object or group. Choose add (you can add
multiple objects). You can find the selected object in the selected object pane.
5 Choose the required Properties.
6 Click Run. The Firmware and Driver versions report is generated.

RAID Configuration
To create a report for RAID Configuration:
1 Click on RAID Configuration. Click Open on the Actions pane.
2 Select a time period for which you want the report generated.

58

Understanding Dell Server Management Pack Suite Operations

book.book Page 59 Wednesday, December 8, 2010 7:33 PM

3 Click on Add Object or Add Group.
4 Click Search, to search for an object or group. Choose add (you can add
multiple objects). You can find the selected object in the selected object pane.
5 Choose the required Properties.
6 Click Run. The RAID configuration report is generated.

Customizing the Dell Server Management
Pack Suite
The Dell Server Management Pack Suite v4.1 allows you to customize
discovery, monitoring, and event processing of your Dell devices. You can
customize the following components of the Dell Management Packs:
•

Monitors — Monitors to assess various conditions that can occur in
monitored objects. The result of this assessment determines the health
state of a target and the alerts that are generated.

•

Object Discoveries — Object discoveries are used to find objects on a network
that need to be monitored.

•

Rules — Rules are used to collect data, such as events generated
by managed objects.
NOTE: See the Microsoft System Center Operations Manager 2007 SP1/ R2
documentation for more information.

Unit Monitors
You can customize the following parameters of the Dell Server Management
Pack Suite v4.1 unit monitors by using overrides:
•

Enabled: Allows you to enable or disable Monitors. You can choose the
Override Setting to be True or False.

•

Interval in Seconds: The frequency (in seconds) with which the
Dell Management Pack polls the Dell device to check the health
of a component.

Understanding Dell Server Management Pack Suite Operations

59

book.book Page 60 Wednesday, December 8, 2010 7:33 PM

The unit monitors can be:
•

Event Monitor: This Monitor is triggered by the event that the Dell
instrumentation logs in the Windows event log, indicating the health of
the corresponding object.

•

Unit Monitor: This Monitor is triggered by a periodic poll configured as
IntervalSeconds.

Table 3-5 illustrates the various Dell monitors and the applicable parameters
for your Dell devices.
Table 3-5. Dell Unit Monitors in Management Pack
Groups

Unit Monitor

Memory
Dell Server Memory Status

Event and Periodic

Memory Unit Instance
Detailed Memory Event Monitor

Event

Detailed Memory Unit Monitor

Periodic

OpenManage Software Services
DSM Connection Service Availability Status

Windows Service

DSM Data Manager Availability Status

Windows Service

DSM Event Manager Availability Status

Windows Service

DSM Shared Service Availability Status

Windows Service

DSM Storage Service Availability Status

Windows Service

WMI Service Availability Status

Windows Service

Power Supplies
Dell Server Power Supplies Status

Event and Periodic

Power Supplies Unit Instance
Detailed Power Supply

Event and Periodic

Processor
Dell Server Processors Status
Processor Unit Instance

60

Understanding Dell Server Management Pack Suite Operations

book.book Page 61 Wednesday, December 8, 2010 7:33 PM

Table 3-5. Dell Unit Monitors in Management Pack (continued)
Groups

Unit Monitor

Detailed Processor

Event and Periodic

Sensors
Dell Server Battery Status

Event and Periodic

Dell Server Current Status

Event and Periodic

Dell Server Fans Status

Event and Periodic

Dell Server Intrusion Sensor Status

Event and Periodic

Dell Server Temperature Sensor Status

Event and Periodic

Dell Server Voltage Sensor Status

Event and Periodic

Storage

Event and Periodic

Storage Connector Physical Disk Group

Event and Periodic

Storage Controller
Storage Controller Status

Event and Periodic

Storage Controller Connector Instance
Controller Connector Event Monitor

Event

Controller Connector Unit Monitor

Periodic

Storage Controller EMM Instance
Enclosure EMM Event Monitor

Event

Enclosure EMM Unit Monitor

Periodic

Storage Controller Enclosure Instance
Controller Enclosure Event Monitor

Event

Controller Enclosure Unit Monitor

Periodic

Storage Controller Physical Disk Instance
Controller Physical Disk Event Monitor

Event

Controller Physical Disk Unit Monitor

Periodic

Enclosure Physical Disk Event Monitor

Event

Enclosure Physical Disk Unit Monitor

Periodic

Storage Controller Power Supply Instance

Understanding Dell Server Management Pack Suite Operations

61

book.book Page 62 Wednesday, December 8, 2010 7:33 PM

Table 3-5. Dell Unit Monitors in Management Pack (continued)
Groups

Unit Monitor

Enclosure Power Supply Event Monitor

Event

Enclosure Power Supply Unit Monitor

Periodic

Storage Controller Sensors
Controller Sensor Event Monitor

Event

Controller Sensor Unit Monitor

Periodic

Storage Controller Virtual Disk Group

Event and Periodic

Storage Controller Virtual Disk Instance

Event and Periodic

Storage Enclosure Physical Disk Group

Event and Periodic

Storage Enclosure Sensors

Event and Periodic

Network Interfaces Group(Basic)
Global Network Interfaces (Basic) Connection
Status

Event and Periodic

Network Interfaces Group(Enriched)
Global Enriched Network Interfaces Status

Event and Periodic

Global Network Interfaces(Basic) Connection
Status

Event and Periodic

Physical Network Interface Instance (Basic)
Connection Status

Event and Periodic

Physical Network Interface Instance (Enriched)
Administrative Status

Event and Periodic

Connection Status

Event and Periodic

Link Status

Event and Periodic

Operational Status

Event and Periodic

Teamed Network Interface Instance(Basic)
Teamed Network Interface (Basic) Availability
Status

Event and Periodic

Teamed Network Interface Instance(Enriched)

62

Understanding Dell Server Management Pack Suite Operations

book.book Page 63 Wednesday, December 8, 2010 7:33 PM

Table 3-5. Dell Unit Monitors in Management Pack (continued)
Groups

Unit Monitor

Teamed Network Interface Instance(Enriched)
Administrative Status

Event and Periodic

Teamed Network Interface Instance(Enriched)
Connection Status

Event and Periodic

Teamed Network Interface Instance (Enriched) Link Event and Periodic
Status
Teamed Network Interface Instance(Enriched)
Operational Status

Event and Periodic

Teamed Network Interface Instance(Enriched)
Redundancy Status

Event and Periodic

CMC
Dell CMC Status

Event and Periodic

DRAC/MC
Dell DRAC/MC Status

Event and Periodic

Dell Remote Access Controller 4
Dell RemoteAccess Status

Event and Periodic

Dell Remote Access Controller 5
Dell RemoteAccess Status

Event and Periodic

iDRAC
Dell Server iDRAC Network Interface Monitor

Periodic

Dell RemoteAccess Status

Event and Periodic

iDRAC Modular
Dell RemoteAccess Status

Event and Periodic

iDRAC Monolithic
Dell RemoteAccess Status

Event and Periodic

Understanding Dell Server Management Pack Suite Operations

63

book.book Page 64 Wednesday, December 8, 2010 7:33 PM

Object Discoveries
You can customize the following Dell Management Pack discovery
parameters, using overrides:
Enabled: Allows you to enable or disable discoveries. You can choose the
Override Setting to be True or False.
Interval in Seconds: The frequency (in seconds) with which the Dell
Management Pack discovers the component instance and attributes of your
Dell device. The default value for this attribute is 24 hours (one day).

Rules
Dell Systems Event Processing Rules

The Dell Management Pack processes rules from Server Administrator,
Server Administrator Storage Management events, DRAC, and CMC traps.
Server Administrator

All informational, warning, and critical events for Server Administrator have
a corresponding event processing rule.
Each of these rules are processed based on the following criteria:

64

•

Source Name = "Server Administrator"

•

Event ID = Actual event ID of the Server Administrator
instrumentation event

•

Severity = Severity of the actual event

•

Data Provider = Windows system event log

Understanding Dell Server Management Pack Suite Operations

book.book Page 65 Wednesday, December 8, 2010 7:33 PM

Storage Management

All informational, warning, and critical events for the Server Administrator
Storage Management Service have a corresponding event processing rule.
Each of these rules are processed based on the following criteria:
•

Source Name = "Server Administrator"

•

Event ID = Actual event ID of the Server Administrator Storage
Management Service event

•

Severity = Severity of the actual event

•

Data Provider = Windows system event log

DRAC / CMC / DRAC/MC

All informational, warning, and critical SNMP traps for the DRAC, CMC,
and DRAC/MC devices have a corresponding SNMP trap rule.
Each of these rules are processed based on the following criteria:
•

Source Name = "DRAC/CMC/DRAC/MC name/ip"

•

OID = Actual trap ID of the DRAC /CMC/DRAC/MC SNMP trap event

•

Severity = Severity of the actual event

•

Data Provider = SNMP trap

Performance Collection Rules

There are nine performance collection rules that collect information on the
following parameters:
•

Ambient Temperature

•

Amperage Per Power supply

•

Energy Consumption

•

Peak Amperage

•

Peak Power

•

Physical Network Interface

•

Power Consumption (Watts)

•

Power Consumption (in BTU/hr)

•

Teamed Network Interface

Understanding Dell Server Management Pack Suite Operations

65

book.book Page 66 Wednesday, December 8, 2010 7:33 PM

In the Operations Console, click DellPerformance and Power Monitoring
Views to view the performance information that is collected from Dell
Systems. This feature is available on installation of Scalable Server
Management Pack. By default this feature is disabled.
To enable this feature:
1 Open the Authoring pane in the Operations Console.
2 Select Rules.
3 Right-click the rule you want to enable.
For example, to enable information to be collected on Network Interface,
of all Dell Systems, perform step 4 to step 6 for the rules listed below:
•

Total Transmitted Packets

•

Received Bytes

•

Total Received Packets

•

Transmitted Bytes

4 Select Overrides  Override the rule  For all objects of class
5 Select Override and provide Override value as True.
6 Click Apply.
Alternatively, when the Detailed Server Management Pack is imported,
these disable Performance collection rules are enabled by default.
NOTE: Network Statistics are defined in Detailed MP only and are disabled by
default. Enable them manually.

66

Understanding Dell Server Management Pack Suite Operations

book.book Page 67 Wednesday, December 8, 2010 7:33 PM

Related Documentation and
Resources

4

This chapter gives the details of documents and references to help you work
with Dell Server Management Pack Suite v4.1

Microsoft Guidelines for Performance and
Scalability for Operations Manager 2007 SP1/R2
For optimal performance, deploy device-specific Dell Management Packs on
different management servers.
For information on Microsoft’s recommendations for scalability, see the
Microsoft website at
http://technet.microsoft.com/hi-in/library/bb735402(en-us).aspx
NOTE: Make sure that the Autogrow Option is enabled in Operations Manager
Data Warehouse and/ or Database for improved performance.

Other Documents You May Need
Besides this User's Guide, you may need to refer to the following guides
available on the Dell Support website at support.dell.com/manuals. On the
Manuals page, click Software Systems Management. Click the appropriate
product link on the right-side to access the documents.
•

Dell Integrated Remote Access Controller User’s Guide

•

Dell Chassis Management Controller User’s Guide

•

Dell OpenManage Installation and Security User's Guide

•

Dell OpenManage Software Quick Installation Guide

•

Dell OpenManage Server Administrator Compatibility Guide

•

Dell OpenManage Server Administrator CIM Reference Guide

•

Dell OpenManage Server Administrator Messages Reference Guide

Related Documentation and Resources

67

book.book Page 68 Wednesday, December 8, 2010 7:33 PM

•

Dell OpenManage Server Administrator Command Line Interface User's
Guide

•

Dell OpenManage Baseboard Management Controller Utilities User’s
Guide

•

Dell Remote Access Controller 4 User's Guide

•

Dell Remote Access Controller 5 User’s Guide

•

Dell Remote Access Controller Racadm User's Guide

•

Dell Life Cycle Controller User’s Guide

•

Dell Remote Access Controller/ Modular Chassis User's Guide

The Glossary provides information about the terms used in this document.
The Dell Systems Management Tools and Documentation DVD contains
a readme file for Server Administrator and additional readme files for
other systems management software applications found on the DVD.

Obtaining Technical Assistance
If at any time you do not understand a procedure described in this guide,
or if your product does not perform as expected, different types of help are
available. For more information see "Getting Help" in your system’s Hardware
Owner’s Manual.
Additionally, Dell Enterprise Training and Certification is available;
see www.dell.com/training for more information. This service might not be
offered in all locations.

68

Related Documentation and Resources

book.book Page 69 Wednesday, December 8, 2010 7:33 PM

A

Appendix A- Issues and Resolutions
Issues and Resolutions
The following table lists the known issues, resolutions, and where the issues
are applicable to.
Table A-1.

Issues and Resolutions

Issue

Resolution

Applicable To

Dell alerts not getting sorted
according to age

Check the registry on the
SCOM 2007 SP1,
machine that has this problem. SCE 2007 SP1
In some instances, when you
import an MP with changes to
the sort flags, it may not get
updated in the registry. If you
delete the settings for the view
in the registry, they are
recreated from the new MP
when you navigate to that view
again. You can also edit the sort
flags in the registry for the view.
Registry edit:
HKEY_CURRENT_USER\Sof
tware\Microsoft\Micro
soft Operations
Manager\3.0\Console\%
GUID.ViewTitle%AlertV
iew\Age
For sorting to be enable ensure
the keys IsSortable and
IsSorted are set to 1.

Appendix A- Issues and Resolutions

69

book.book Page 70 Wednesday, December 8, 2010 7:33 PM

Table A-1. Issues and Resolutions (continued)
Issue

Resolution

Under certain conditions,
alerts related to Handle Count
Threshold and Private Bytes
Threshold are displayed on the
Operations console of the
management server.

Microsoft KB968760 available SCOM 2007 SP1,
on the Microsoft support site SCE 2007 SP1
at support.microsoft.com
resolves this.

Under certain conditions, an
error message is displayed on
the Operations Console of the
management server with the
Event ID – 623 and Event
Source – Health Service ESE
Store.

Microsoft KB975057 available SCOM 2007 SP1,
on the Microsoft support site SCE 2007 SP1
at support.microsoft.com
resolves this.

The System Center Operations Microsoft KB951327,
Manager 2007 console may
KB951526 available on the
crash
Microsoft support site at
support.microsoft.com
resolves this.
You may experience one or
more of the following
situations:
The Web Console does
not open.

Applicable To

SCOM 2007 SP1,
SCE 2007 SP1

Microsoft KB954049 available SCOM 2007 SP1,
on the Microsoft support site SCE 2007 SP1
at support.microsoft.com
resolves this

The My Workspace page
does not display.
Performance and Power
Monitoring Views do not
display.
The reports do not appear as
expected in the Reporting
space of the Administration
console.

70

Microsoft KB954643 available SCOM 2007 SP1,
on the Microsoft support site SCE 2007 SP1
at support.microsoft.com
resolves this.

Appendix A- Issues and Resolutions

book.book Page 71 Wednesday, December 8, 2010 7:33 PM

Table A-1.

Issues and Resolutions (continued)

Issue

Resolution

Applicable To

In the Diagram view for Dell
network devices, the basic
attributes are displayed for the
Dell DRAC and CMC objects.

To resolve this issue, you can
view the detailed set of
attributes by clicking on the
objects in the State View.

Dell Remote Access
MP, Dell Chassis
Management
Controller MP.

The health of your Dell
system’s hardware log is not
monitored by the
Dell Management Pack.

You can view your Dell
system’s hardware log on the
Server Administrator.

Dell Scalable MP

• Make sure that OMSA or
Dell CMC MP
Server Modules and Chassis
DRAC Tools are installed on
Slot Summary Information are
the management server
not visible under CMC or
managing the CMC or
DRAC/MC
DRAC/MC.
• Make sure that you have
configured the
RunAsAccounts for CMC or
DRAC/MC devices and
associated them with "Dell
CMC Login Account" or
"Dell DRAC/MC Login
Account".
• Make sure that "Dell CMC
Slot Discovery" and "Dell
DRAC/MC Slot Discovery"
rules are enabled from the
Authoring pane of
Operations console.

Appendix A- Issues and Resolutions

71

book.book Page 72 Wednesday, December 8, 2010 7:33 PM

Known Limitations
Table A-2. Limitations in SCOM/SCE and Dell Server Management Pack Suite 4.1
Limitation

Applicable to

Security: Dell MP, Power Control and LED tasks SCOM/SCE and Dell Server
use only the default credentials. When you create Management Pack Suite.
a new task in the Authoring pane and view it, you
can see the username and the password you
specified. The credentials are not hidden when
you view the task
When using health explorer, some unit monitors SCOM/SCE and Dell Server
in Dell Management Pack (under Sensors and
Management Pack Suite.
OpenManage Services instances) may show green
status though the sub-instance does not exist.
This is because unit monitors cannot have an
Unavailable state when the target class is present
and the unit monitor has been executed.
Intrusion unit monitor status under sensors is only Dell Server Management Pack
Suite.
for chassis and does not include health of bezel
intrusion.

72

Appendix A- Issues and Resolutions



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.3
Linearized                      : No
Has XFA                         : No
Format                          : application/pdf
Creator                         : Dell Inc.
Title                           : Dell Server Management Pack Version 4.1 for Microsoft System Center Operations Manager User's Guide
Subject                         : User's Guide
Description                     : User's Guide
Producer                        : Acrobat Distiller 9.3.3 (Windows); modified using iTextSharp 5.1.3 (c) 1T3XT BVBA
Keywords                        : all-products#esuprt_electronics#esuprt_software#esuprt_client_sys_mgmt#dell srvr mgmt pck v4.1 for ms sys center opr mangr#dell-srvr-mgmt-pck-v4.1-for-ms-sys-center-opr-mangr#User's Guide
Create Date                     : 2010:12:08 11:10:37Z
Creator Tool                    : FrameMaker 7.1
Modify Date                     : 2013:12:24 12:23:21-06:00
Page Mode                       : UseOutlines
Page Count                      : 72
Author                          : Dell Inc.
Productcode                     : dell-srvr-mgmt-pck-v4.1-for-ms-sys-center-opr-mangr
Typecode                        : ug
Typedescription                 : User's Guide
Languagecodes                   : en-us
Sectioncode                     : 
Sectiondescription              : 
Publishdate                     : 2010-12-08 00:00:00
Expirydate                      : 9999-09-09 00:00:00
Manualurl                       : http://ftp.dell.com/manuals/all-products/esuprt_electronics/esuprt_software/esuprt_client_sys_mgmt/dell-srvr-mgmt-pck-v4.1-for-ms-sys-center-opr-mangr_User's Guide_en-us.pdf
Readytocopy                     : false
Futureproductindication         : Yes
Categorypathforfutureproducts   : all-products/esuprt_electronics/esuprt_software/esuprt_client_sys_mgmt
Businesskeywords                : 
Filesize                        : 1706
Creationdate                    : D:20101208111037Z
Moddate                         : D:20121107054816-06'00'
EXIF Metadata provided by EXIF.tools

Navigation menu