Delta Electronics PPMN3U SUB 1G module User Manual
Delta Electronics, Inc. SUB 1G module
User Manual
MyDeltaSolar DC1 and User Interface Aska Chiu 2018.09.13 'RZQORDG0\'HOWD6RODU$33 | Download APP MyDeltaSolar 1. This APP should collocate with data collector and Delta Inverter. 2. If inverter is not connected to cloud, you still can monitor inverter operation by APP. Where can search for MyDeltaSolar APP? - QR Code : Please scan the QR code to DSC cloud (web). - IOS system : Please search “MyDeltaSolar” in App store. - Android system : Please search “MyDeltaSolar” in Google Play. QR Code Delta Confidential IOS Android https://itunes.apple.com/ng/app/myd eltasolar/id1271609228?mt=8 https://play.google.com/store/apps/de tails?id=com.mydeltasolar_1_0_0.app &hl=zh-TW &UHDWHDQHZDFFRXQW | User & Plant Register Of Cloud Login Login : Use MyDeltaSolar Service terms and conditions : 1. Please fill in user e-mail & password. You must need a MyDeltaSolar account in order to use our *If you have registered, the mobile will cloud services. Delta may collect your personal data and E-mail@example.com protect your privacy when you use MyDeltaSolar service. By remember account info. Then please fill in password. using MyDletaSolar service, you agree that Delta can use such data and monitor your inverter’s status if necessary. In some case, Delta employees, authorized contractors or 8-16 characters agents may need to use your account to analyze any issue and problem you have while using Delta solar inverter or Forget password Create account Language service. We restrict access to personal information to Delta 3. User have to check the box enable "Go to Register" button. to employees, contractors and agents who need to know that V1.15 2. Please click “Create account” to create an user‘s account. information in order to process it for us, and who are subject Sign In to strict contractual confidentiality obligations and may be 4. Please click “Go to Register” to register. disciplined or terminated if they fail to meet these V1.19 Go to Register obligations. I had read and agree this declaration as above. Go to Register Delta Confidential Cloud Register & Plant Register | User & Plant Register Of Cloud - REGISTER : Cloud Register Aska.chiu@deltaww.com Cloud Register Aska.chiu@deltaww.com One account can register many plants. - USE CLOUD / DC1 : Yes -> Switch to cloud page. No -> Home page ( DC1 Monitor ). Plant 1 France If one country have multi-grid code, user have to choose the correct grid code. e.g. User choose France here : *The location will record in the cloud to service. Register Delta Confidential Register Please turn on DC1 | Connect to DC1 Wi-Fi Connection Procedure by APP 1. Turn on DC1. Delta-O1W14800005W0-DC1 2. Turn on Wi-Fi function of mobile device. (cell phone, tablet) 3. Search and choose DC1’ SSID (Delta-serial number-DC1). 4. Enter the default password “DELTASOL” to get DC1 connected. 5. Open MyDeltaSolar APP. Delta-O1W14800005W0-DC1 Turn on DC1. Inverter connected. Internet is success. Delta Confidential Change password | Network CHANGE DC1’S WI-FI PASSWORD Network CHANGE DC1’S WI-FI PASSWORD Connect to DC1 And Setting - CHANGE DC1’S PASSWORD : 1. Same as cloud account : The system enter user's password automatically. 2. Others : User can change password, and fill in “confirm password” to double confirm. *Change your password by using strong one what you don‘t use elsewhere immediately to protect your account. Change Password Data collector’s password has been updated! Please use the new password next time you login. OK - Connection (page 9-13) : If this data collector isn’t set up yet, APP will direct to this page and start the following set up procedure. - Network (page 14) : If user want this data collector uses delta cloud service, but it’s network connection is not set up yet. - Cloud (page 15) : If this data collector is completely set up, APP wilt direct to cloud page. Set Delta Confidential Set Please select country and grid code, then go to home page | Search Auto RS485 - Search Button : Connection Connection Wi-Fi Sub-1G Search Auto DC1 SETTING SET INV RS485 : France IEEE1547 Frequency : 915 925 MHz MHz Scan Frequency Wi-Fi GET INFO Grid Code Sub-1G SYNC TIME Select Sub-1G and click Search button to start DC1 setting process. -------------------------------------------If this data collector isn’t set up yet, APP will direct to this page and start the following set up procedure ( page 9-13 ). -------------------------------------------Grid Code : Select specific grid codes for utility. Will be written into inverters. Frequency : Select the desired frequency to scan for quality. Quality : 100 If the quality value is not 100, there might be some devises are using this frequency band. Communication may be disturbed by these devices. Block Setting Block : Connect to DC1 And Setting 1. Scan one frequency is 10 s. 2. Quality = 100 is OK to use. Quality < 100 has been used. 3. Sort : Good (top) Æ Bad (bottom) - Searching Inverters ... Block 1 - Every Data collector in same plant should be set an unique Block ID carefully. - Duplicated Block ID is not allowed. Search Inverters Delta Confidential Search Inverters and Set ID | Connection DC1 SETTING SET INV SYNC TIME Auto ID Select All Serial Number ID SNR RSSI DC1 SETTING SET INV GET INFO SYNC TIME Auto ID Select Select All All Serial Number ID SNR RSSI DE000000000801 -72 DE000000000801 -72 DE000000000802 -76 DE000000000802 -76 DE000000000803 -79 DE000000000803 -79 DE000000000804 -82 DE000000000804 -82 DE000000000805 -86 DE000000000805 -86 DE000000000806 -89 DE000000000806 -89 DE000000000807 -92 DE000000000807 -92 DE000000000808 -93 DE000000000808 -93 DE000000000809 -1 -96 DE000000000809 -1 -96 DE000000000810 -99 DE000000000810 -99 DE000000000811 -101 DE000000000811 -101 DE000000000812 -1 -103 DE000000000812 -1 -103 Refresh Confirm Inverters Confirm Inverter Delta Confidential - Select All : Connection GET INFO Connect to DC1 And Setting This button will select all inverters. When there are more than 25 inverters, the top most 25 inverters will be selected. - RSSI : Indicate the signal quality of every inverter. The larger is better. * The search result will be sorted by RSSI, the most recommended inverters will on the top of the list. Refresh Confirm Inverters Confirm Inverter Search Inverters and Set ID | Connection DC1 SETTING SET INV - Auto ID : Connection GET INFO SYNC TIME Auto ID Select Select All All DC1 SETTING SET INV Connect to DC1 And Setting GET INFO SYNC TIME This button will automatically assign an unique ID to every inverter which is selected. Auto ID Select Select All All Serial Number ID SNR RSSI Serial Number ID SNR RSSI DE000000000801 -72 DE000000000801 -72 DE000000000802 -76 DE000000000802 -76 DE000000000803 -79 DE000000000803 -79 DE000000000804 -82 DE000000000804 -82 DE000000000805 -86 DE000000000805 -86 DE000000000806 -89 DE000000000806 -89 DE000000000807 -92 DE000000000807 -92 DE000000000808 -93 DE000000000808 -93 DE000000000809 -1 -96 DE000000000809 -1 -96 DE000000000810 -99 DE000000000810 -99 DE000000000811 -101 DE000000000811 10 -101 DE000000000812 -1 -103 DE000000000812 11 -1 -103 Refresh Confirm Inverters Confirm Inverter Success Refresh Confirm Inverters Confirm Inverter Delta Confidential - Confirm Inverter: User cannot select more than 25 inverters, and duplicated ID is not allowed. Search Inverters and Set ID | Connection DC1 SETTING SET INV Connection GET INFO SYNC TIME DC1 SETTING Auto ID Select All Serial Number Select Select All All Serial Number ID SNR RSSI DE000000000801 -72 DE000000000802 -76 DE000000000803 -79 Confirm Inverter DE000000000804 3 & Set ID-82 AreDE000000000805 you sure you want to4 select 3and set -86 ID of these inverters? DE000000000806 -89 -92 *Unselected inverters will not be monitored by this data 6collector. DE000000000807 No DE000000000808 DE000000000809 Yes -93 -1 -96 DE000000000810 -99 DE000000000811 10 -101 DE000000000812 11 -1 -103 Refresh Confirm Inverters Confirm Inverter Delta Confidential Connect to DC1 And Setting SET INV GET INFO ID SNR RSSI SYNC TIME Status OK DE000000000801 -72 DE000000000802 -76 DE000000000803 -79 OK DE000000000804 -82 OK DE000000000805 -86 OK DE000000000806 -89 OK DE000000000807 -92 OK DE000000000808 -93 OK DE000000000809 -1 -96 OK DE000000000810 -99 OK DE000000000811 10 -101 OK DE000000000812 11 -1 -103 OK DE000000000813 12 -1 -105 OK OK : Set inverter ID success. Fail : Set inverter ID fail, need refresh. Success Refresh Confirm InvertersGet Info - Status : - Get Info All selected inverters need to be set ID successfully. 10 Search Inverters and Set ID | Connection DC1 SETTING SET INV Connection GET INFO Serial Number ID DE000000000801 -72 DE000000000802 -76 DE000000000803 -79 DE000000000804 DE000000000805 DE000000000806 SYNC TIME Status DC1 SETTING SET INV GET INFO SYNC TIME Status Serial Number ID DE000000000801 -72 DE000000000802 -76 OK DE000000000803 -79 OK -82 OK DE000000000804 -82 OK -86 OK DE000000000805 -86 OK -89 OK DE000000000806 -89 OK DE000000000807 -92 OK DE000000000807 -92 OK DE000000000808 -93 OK DE000000000808 -93 OK DE000000000809 -1 -96 OK DE000000000809 -1 -96 OK DE000000000810 -99 OK DE000000000810 -99 OK DE000000000811 10 -101 OK DE000000000811 10 -101 OK DE000000000812 11 -1 -103 OK DE000000000812 11 -1 -103 OK DE000000000813 12 -1 -105 OK DE000000000813 12 -1 -105 OK SNR RSSI Refresh Confirm InvertersSync time Delta Confidential Connect to DC1 And Setting OK SNR RSSI OK Refresh Confirm Inverters Next 11 After user choose an available Wi-Fi network, then pop-up the message | Network CLOUD REGISTER Specific SSID Network CONNECT TO INTERNET Scan Connect to Cloud - Search Internet : 1. User click “search” icon to search Wi-Fi access point. 2. Please choose an available Wi-Fi access point. Status - Register Fail : The message box would indicate the reason why register was failed. Cloud Register Cloud register success! Press ok to go to cloud page. Register Fail Please connect to internet and push the 'status' button to check what happened. If you cannot solve the problem please contact your local Installer. OK OK -------------------------------------------If user want this data collector uses delta cloud service, but it’s network connection is not set up yet. Show this page. -------------------------------------------- Show Password Please fill in the Wi-Fi’s password, then click “Connect” button. Delta Confidential 12 Connect to MyDeltaSolar cloud | Use MyDeltaSolar Service terms and conditions : Connect to Cloud Cloud You must need a MyDeltaSolar account in order to use our cloud services. Delta may collect your personal data and protect your privacy when you use MyDeltaSolar service. By using MyDletaSolar service, you agree that Delta can use such data and monitor your inverter’s status if necessary. In some case, Delta employees, authorized contractors or agents may need to use your account to analyze any issue and problem you have while using Delta solar inverter or service. We restrict access to personal information to Delta TOTAL ENERGY : 0.1 kWh employees, contractors and agents who need to know that information in order to process it for us, and who are subject to strict contractual confidentiality obligations and may be disciplined or terminated if they fail to meet these obligations. France 0 kWh Delta Confidential 13 Antenna Type Delta Part No. 0990236424 Frequency Range 868~928 MHz Impedance VSWR 50Ω ≤2.5 Radiation Gain ≤2.0 Omni 2.0 dBi 14 Delta Confidential 0990242124 1.5 dBi For All device (15.21) Warning: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user authority to operate the equipment. For mobile device 1. To comply with FCC RF exposure compliance requirements, a separation distance of at least 20 cm must be maintained between the antenna of this device and all persons. (Not including low power device (below 20mW)) 2. This Transmitter must not be co-located or operating in conjunction with any other antenna or transmitter For Class B digital device or peripheral or cordless phone (15.105) This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: 䕺 Reorient or relocate the receiving antenna. 䕺 Increase the separation between the equipment and receiver. 䕺 Connect the equipment into an outlet on a circuit different from that to which the receiver is needed. 15 for help. 䕺 Consult the dealer or an experienced radio/TV technician Delta Confidential This device is intended only for OEM integrators under the following conditions: 1) The antenna must be installed such that 20 cm is maintained between the antenna and users. For laptop installations, the antenna must be installed to ensure that the proper spacing is maintained in the event the users places the device in their lap during use (i.e. positioning of antennas must be placed in the upper portion of the LCD panel only to ensure 20 cm will be maintained if the user places the device in their lap for use) and 2) The transmitter module may not be co-located with any other transmitter or antenna. As long as the 2 conditions above are met, further transmitter testing will not be required. However, the OEM integrator is still responsible for testing their end-product for any additional compliance requirements required with this module installed (for example, digital device emissions, PC peripheral requirements, etc.). IMPORTANT NOTE: In the event that these conditions can not be met (for example certain laptop configurations or co-location with another transmitter), then the FCC authorization is no longer considered valid and the FCC ID can not be used on the final product. In these circumstances, the OEM integrator will be responsible for re-evaluating the end product (including the transmitter) and obtaining a separate FCC authorization. End Product Labeling This transmitter module is authorized only for use in devices where the antenna may be installed such that 20 cm may be maintained between the antenna and users (for example access points, routers, wireless ASDL modems, certain laptop configurations, and similar equipment). The final end product must be labeled in a visible area with the following: "Contains TX FCC ID: 2ARTOPPMN3U 16 Delta Confidential Un-license band: This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. 17 Delta Confidential Smarter. Greener. Together. To learn more about Delta, please visit www.deltaww.com.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : Yes Author : RICK.CY.CHANG Create Date : 2019:02:13 11:09:47+08:00 Modify Date : 2019:02:13 11:16:14+08:00 XMP Toolkit : Adobe XMP Core 5.4-c005 78.147326, 2012/08/23-13:03:03 Format : application/pdf Creator : RICK.CY.CHANG Title : Microsoft PowerPoint - MyDeltaSolar_Sub1G_EndUser.pptx Metadata Date : 2019:02:13 11:16:14+08:00 Creator Tool : PScript5.dll Version 5.2.2 Producer : Acrobat Distiller 10.0.0 (Windows) Document ID : uuid:df5a5299-9bc7-4d3d-8c06-fec519de382c Instance ID : uuid:3a22a925-3e17-4087-9f64-3b9f5b906650 Page Count : 18EXIF Metadata provided by EXIF.tools