Intrusion Alarm Systems | DS160 Series High Performance Request‑to‑exit Detectors
DS160 Series High Performance
Request‑to‑exit Detectors
www.boschsecurity.com
uDoor monitor with sounder alert
uSequential Logic Input (SLI)
uInternal vertical pointability
uWrap-around coverage pattern with precise pattern
control
uUp to 64 second adjustable latch time
The DS160 Series consists of the DS160 Detector
(light gray) and the DS161 Detector (black)
specifically designed for Request-to-exit (REX)
applications. With features such as timers, door
monitor with sounder alert, and pointable coverage,
the DS160 and DS161 have the flexibility to meet the
most stringent REX requirements. The exclusive
Sequential Logic Input (SLI) provides added security
that is not offered in any other REX device.
Functions
Sequential Logic Input (SLI)
The SLI terminal allows connection of a second device
to require sequential detection. This eliminates the
possibility that an object that is slid through the door
or underneath the door will activate the detector. This
input can also be used to lock the sensor if motion is
present outside the premises.
Door Monitor
The sensor can monitor a door contact to allow special
control of the internal relay. For example, if the door is
opened within the relay time period, the sensor can be
programmed to halt the timer. If the door is not
opened within a specific time period, the relay can be
programmed to deactivate.
Sounder Alert
An integrated sounder can be programmed to activate
if the door is left open too long. The sounder volume is
fully adjustable to 85 dB.
Keycard Input
The keycard input allows the sensor relay to be
controlled from an external source, such as an access
control system or card reader.
Certifications and approvals
Europe Complies with EN50131‑1 Grade 2
Region Certification
Australia RCM [DS160]
Europe CE 2004/108/EC EMC Directive;
2006/95/EC Low-Voltage Directive;
2011/65/EU Restriction of the use of
certain hazardous substances in electri-
cal and electronic equipment
USA UL ALVY: Access Control Systems Units
(UL294)
Installation/configuration notes
ALARM WILL
SOUND WHEN
DOOR IS
OPENED
3 m
(10 ft)
ALARM WILL
SOUND WHEN
DOOR IS
OPENED
1.2 m
(4 ft)
Front View
Mounted on wall above door and mounted on ceiling .
75 m (2.5 ft) in front of the door.
1.5 m
(5 ft)
3 m
(10 ft)
Side View
The higher that you mount the unit, the larger the
coverage area. Do not mount the DS160/DS161 more
than 4.6 m (15 ft) above the floor.
Side view of coverage pattern with the unit mounted at
4.6 m (15 ft) above the floor with the lens pointed
straight down.
.75 m
(2.5 ft)
1.5 m
(5 ft)
Side View
The higher that you mount the unit, the larger the
coverage area. Do not mount the DS160/DS161 more
than 4.6 m (15 ft) above the floor.
Side view of coverage pattern with the unit mounted at
4.6 m (15 ft) above the floor with the lens pointed
straight down.
Coverage Information
The coverage (detection area) varies depending on the
mounting height above the floor, angle of the lens, and
whether the unit is mounted on a wall above the door
or on the ceiling. The coverage is 2.4 m x 3 m (8 ft x
10 ft) The coverage patterns for the detector at a
height of 2.3 m (7.5 ft) are shown. The coverage
pattern increases or decreases with height and
detector alignment.
Notice
When you mount the unit on the wall and the lens
points straight down, some detection zones point
toward the wall and do not detect movement.
The diagrams depict views of the coverage pattern
with the detector mounted at 2.3 m (7.5 ft) above the
floor with the lens pointed straight down. Zones that
are pointed toward the wall are not shown.
Technical specifications
Environmental
Operating
Temperature:
-29°C to +49°C (-20°F to +120°F)
For UL Certificated installations, 0°C to
+49°C (+32°F to +120°F)
Radio Frequency
Interference (RFI)
Immunity:
No alarm or setup on critical frequencies in
the range from 26 MHz to 1000 MHz at
50 V/m
Complies with Environmental Class II (EN50130-5)
Mechanical
Dimensions: 4.5 cm x 17.1cm x 4.4 cm
(1.80 in. x 6.75 in. x 1.75 in.)
Material: High impact ABS plastic enclosure
Modes
Power Loss
Default:
Programmable fail-safe or fail-secure modes.
Timer: Programmable reset accumulative or non-reset
counting mode.
Electrical
Current Draw: 8 mA nominal standby current, 39 mA at 12 VDC in
alarm
Voltage: 12 VAC or VDC to 30 VAC or VDC
Alarm Output: Two Form C relay contacts each rated 1 A at 30 VAC
or VDC for resistive loads
2 | DS160 Series High Performance Request‑to‑exit Detectors
Indicators: 1 activation LED
Relay Latch
Time:
Adjustable from 0.5 sec to 64 sec.
Ordering information
DS160 Request‑to‑exit Detector
For use in request-to-exit (REX) applications. Provides
PIR 2.4 m x 3 m (8 ft x 10 ft) coverage, timers, door
monitor with sounder alert, and pointable coverage.
Order number DS160
DS161 Request‑to‑exit Detector
Black enclosure. For use in Request-to-EXit (REX)
applications. Provides PIR, 2.4 m x 3 m (8 ft x 10 ft)
coverage, timers, door monitor with sounder alert, and
pointable coverage.
Order number DS161
Accessories
TP160 Trim Plate
A light gray trim plate used when mounting the
detector over a standard single-gang box.
Order number TP160
TP161 Trim Plate
A black trim plate used when mounting the sensor
over a standard single-gang box.
Order number TP161
3 | DS160 Series High Performance Request‑to‑exit Detectors
Represented by:
North America: Europe, Middle East, Africa: Asia-Pacific: China: Latin America and Caribbean:
Bosch Security Systems, Inc.
130 Perinton Parkway
Fairport, New York, 14450, USA
Phone: +1 800 289 0096
Fax: +1 585 223 9180
security.sales@us.bosch.com
www.boschsecurity.us
Bosch Security Systems B.V.
P.O. Box 80002
5617 BA Eindhoven, The Netherlands
Phone: + 31 40 2577 284
Fax: +31 40 2577 330
emea.securitysystems@bosch.com
www.boschsecurity.com
Robert Bosch (SEA) Pte Ltd, Security
Systems
11 Bishan Street 21
Singapore 573943
Phone: +65 6571 2808
Fax: +65 6571 2699
apr.securitysystems@bosch.com
www.boschsecurity.asia
Bosch (Shanghai) Security Systems Ltd.
203 Building, No. 333 Fuquan Road
North IBP
Changning District, Shanghai
200335 China
Phone +86 21 22181111
Fax: +86 21 22182398
www.boschsecurity.com.cn
Robert Bosch Ltda Security Systems Division
Via Anhanguera, Km 98
CEP 13065-900
Campinas, Sao Paulo, Brazil
Phone: +55 19 2103 2860
Fax: +55 19 2103 2862
latam.boschsecurity@bosch.com
www.boschsecurity.com
© Bosch Security Systems 2016 | Data subject to change without notice