DewertOkin CU170 Control Unit User Manual 1
DewertOkin GmbH Control Unit 1
user manual
Quick Reference Guide to RF1058 / CU170 System overview Notice! Electrical components should be connected or disconnected only when the power supply cord is unplugged. Notice! There is a delay after the supply voltage is applied before the device actually turns on. Wait at least 2 seconds before commissioning. Components that can be connected: optional 11 12 13 13 14 15 1. CU170 2. RF1058 3. M1: e.g. DELTADRIVE DS2 4. M2: e.g. DELTADRIVE DZ 5. M3: e.g. DELTADRIVE DZ 6. M4: e.g. DELTADRIVE DZ 7. POWER SUPPLY PD12 8. Power cord 9. Massage motor US Version 10. Junction cable (for 4 massage motors) 11. Optional: POWER DOWN BOX 10 12. Optional: LED-Set with POWER BOX 14. Optional: USB SOCKET optional 13. Optional: Massage motor 16 15. Optional: USB CHARGER 17 16. Optional: Junction cable 17. Optional: Adapter cable 18 19 18. Optional: Junction cable 19. Optional: Synchronous cable 03.04.2017 Id-No. 84625(c) 1 / 12 Quick Reference Guide to RF1058 / CU170 CU170 Connections and functions 1. Connection for (POWER SUPPLY PD12, M1 and M2) 2. Connection socket for M3 3. Connection socket for M4 4. Connection socket for Massage motor 5. Multi-function port for optional accessories 6. Reset button / Pairing button / Pairing LED Technical specifications 03.04.2017 Id-No. 84625(c) Rated voltage 24-29V DC Current consumption max. 6.00A Mode of operation Duty Cycle 2min ON / 18min OFF Protection class III Protection degree IP20 Length x width x height 186mm x 120mm x 38mm Transport / storage temperature from -20°C to +50°C Operation temperature from +10°C to +40°C Relative humidity from 30% to 75% Air pressure from 800hPa to 1060hPa Altitude < 2000m 2 / 12 Quick Reference Guide to RF1058 / CU170 RF1058 11 10 14 13 17 16 19 20 Button 12 15 18 10 11 21 12 13 14 15 16 17 18 19 20 21 1 + 19 3 + 19 13 + 15 16 + 19 16 + 19 LED 03.04.2017 Acknowledgement: The floor lighting will blink twice and a "peep" tone will Function Drive M1 up (head) Drive M3 up (lift) Drive M2 up (foot) Drive M1 down (head) Drive M3 down (lift) Drive M2 down (foot) Drive M4 up (tilt) Drive M4 down (tilt) Head massage higher level Massage on/off Foot massage higher level Head massage lower level Massage wave Foot massage lower level Set memory Under Bed Light on/off Child safety lock on/off Position Flat Memory position Zero G Memory position TV Pairing System 1 Pairing System 2 Press + Release Press + Hold Reset memory position sound to signal the successful completion of the step. 1. Teach-in for the RF1058 or app To start using the RF1058 with a Bluetooth® device, the wireless link with the CU170 must first be established. In order to use a Bluetooth® device (a smart phone or tablet) with your system, you will first need to download and install the "OKIN" app for your device. a. Massage function slow medium fast Automatic teach-in Insert the power plug into a power outlet. The CU170 will be in pairing mode for 120sec which is divided as follows: During the first 60sec, an RF1058 can be discovered (the teach-in). During the next 60sec, a Bluetooth® device can be discovered. The floor lighting and the blue LED are illuminated during this teach-in phase for the RF1058. RF1058: Simultaneously press buttons 1 and 19. A successful pairing will be acknowledged. The floor lighting will switch off after the teach-in process for the RF1058 is finished. The blue LED for pairing with a Bluetooth® device starts flashing. The blue LED switches off when the Bluetooth® pairing process has timed out or when the device has connected successfully. A successful pairing will be acknowledged. If, during the RF1058 teach-in process, you press any button on an already paired RF1058, then it switches to the Bluetooth® teach-in mode. If the RF1058 or a Bluetooth® device is discovered during the pairing phase, then this pairing mode is automatically ended. The floor lighting and the blue LED switch off. Repeat the automatic teach-in process. First, remove the plug from the power supply. Then wait 60sec and insert the plug back into the power supply. You can now start the new teach-in process. When operating a system in parallel, you must execute the teach-in processes for the CU170s sequentially. First, connect the CU170 to the power supply. Then execute the teach-in process for the first RF1058 or Bluetooth® device. Then execute the teach-in for the second device. Note! Id-No. 84625(c) Only commission one system at a time. Never configure multiple systems simultaneously 3 / 12 Quick Reference Guide to RF1058 / CU170 b. Manuel teach-in The system must be connected to the power supply. 3. Quickly press the Reset/Pairing button twice on the CU170 (button 6). The floor lighting and the green pairing LED will illuminate. The CU170 is now in pairing mode for 120 seconds, which is divided as follows: During the first 60 seconds, an RF1058 can be discovered (the teach-in). During the next 60 seconds, a Bluetooth® device can be discovered. The floor lighting and the blue LED are illuminated during this teach-in phase for the RF1058. RF1058: Simultaneously press buttons 1 and 19. A successful pairing will be acknowledged. The floor lighting will switch off after the teach-in process for the RF1058 is finished. The blue LED for pairing with a Bluetooth® device starts flashing. The blue LED switches off when the Bluetooth® pairing process has timed out or when the device has connected successfully. A successful pairing will be acknowledged. If, during the RF1058's teach-in process, you press any button on an already paired RF1058, then it switches to the Bluetooth® teach-in mode. If the RF1058 or a Bluetooth® device is discovered during the pairing phase, then this pairing mode is automatically ended. The floor lighting and the blue LED switch off. When operating a system in parallel, you must execute the teach-in processes for the CU170s sequentially. First, connect the CU170 to the power supply. Then execute the teach-in process for the first RF1058 or Bluetooth® device. Then execute the teach-in for the second device. Note! 2. Only commission one system at a time. Never configure multiple systems simultaneously. Locking or enabling the RF1058 Press and hold button 18 for about three seconds: this will either enable or lock the RF1058. A successful pairing will be acknowledged. Adjusting the intensity of the massage To turn the massage function (head and foot end) on or off, press button 11 on the RF1058. If the massage function is turned off, it can be activated by pressing button 10, 12, 13 or 15. If the massage function is turned on, it can be deactivated, starting from the lowest intensity, by pressing button 13 or 15. The massage intensity is changed through 4 steps each time one of the buttons 10, 12, 13 or 15 is pressed. Press the WAVE button 14 to switch between the three interval levels. This is then indicated by the LEDs above the massage function on the RF1058. 4. Execute a reference movement The referencing must be execute in the following scenarios: The initial commissioning A change in hardware After the battery-powered electrical reset function has been execute. The CU170 has a positional feedback feature. A referencing movement must first be carried out before this feature can function properly. Press and hold the reset/pairing button (6) on the CU170 until the end position has been reached. A successful pairing will be acknowledged. 5. Saving the memory positions You can save two different memory positions on the buttons "ZGRAV / TV" as follows: Move to the desired position using buttons 1 to 9. Press and hold button 16 (SET) for one second. Within three seconds, press button 20 (ZGRAV) or button 21 (TV) in order to save the position, this is confirmed by a "beep" signal. The desired position is now saved on buttons 20 or 21. You can overwrite the saved memory position at any time by repeating this process. 03.04.2017 Id-No. 84625(c) 4 / 12 Quick Reference Guide to RF1058 / CU170 6. Switching to automatic movements and factory settings 8. The buttons FLAT, ZGRAV and TV can be used for various saved positions. Press the respective button briefly (press and release) to move to that position. The button does not need to be held down. CAUTION! Only connect the electrical components when the power supply is switched off. Two systems can be moved and operated simultaneously (parallel mode) using one RF1058. Proceed as follows to establish communications: Deactivate (factory default) Press the Reset/Pairing button on the CU170 (button 6) to move both systems to their end positions. Execute the teach-in process first for system 1 (button 1 +19) and then for system 2 (button 3 +19). Note that the teach-in processes are always sequential. The teach-in should never be carried out on two systems at the same time. Press buttons 16 and 19 for about five seconds simultaneously, the The teach-in cannot be execute for a second RF1058 in this mode. Activate Press buttons 13 and 15 for about five seconds simultaneously, the Press + Release mode is activated. A successful pairing will be acknowledged. Press + Release mode is deactivated. The Press + Hold mode is activated. The memory positions of ZGRAV and TV are reset to factory default. A successful pairing will be acknowledged. 7. Moving two systems in parallel using remote radio signals Moving two systems in parallel using a sync cable CAUTION! Only connect the electrical components when the power supply is switched off. Two operating systems can be connected to each other using a sync cable at the multi-function port. In this way, they can be run simultaneously. Press the Reset/Pairing button on the CU170 (button 6) to move both systems to their end positions. Disconnect the power plug on both systems from the power socket. Connect both systems by connecting the proper synchronous cable to the multi-function port. Insert the mains plug from both systems into the power socket. Parallel operations are possible as soon as both systems are connected to the power supply. Both programmed RF remotes can be used to move the systems. 03.04.2017 9. Cleaning and care This system was designed so that it would be easy to clean. Be sure to unplug the power cord of the power socket before you begin cleaning it! Use a dry antistatic cloth to clean the system Be sure that you do not damage the connecting cables during the cleaning. 10. Disposal The system consists of electronic components, cables and metal and plastic parts. You should observe all corresponding national and regional environmental regulations when disposing of the system. The disposal of the end product is regulated in Germany by Elektro-G, internationally by the EU Directive 2011/65/EC (RoHS), or by any applicable national laws and regulations. (The end product is not regulated by the EU Directive 2012/19/EC (WEEE)). This system should not be disposed of with normal household waste! Id-No. 84625(c) 5 / 12 Quick Reference Guide to RF1058 / CU170 FCC WARNING This device complies Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Section 15.21 Information to user Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/ TV technician for help. IC WARNING This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that my cause undesired operation of the device. Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio exempts de licence. Lexploitation est autorisée aux deux conditions suivantes: (1) l’appareil ne diot pas produire de brouillage, et (2) l’utilisateur de lappareil diot accepter tout bouillage radioélectrique subi, méme si le brouillage est susceptible d’en compromettre le fonctionnement. 03.04.2017 Id-No. 84625(c) DewertOkin GmbH Weststraße 1 32278 Kirchlengern Germany Phone: +49 (0)5223/979-0 Fax: +49 (0)5223/75182 http://www.dewertokin.de Info@dewertokin.de 6 / 12 Kurzanleitung RF1058 / CU170 Systemübersicht Achtung! Sie dürfen elektrische Komponenten nur bei gezogenem Netzstecker anschließen oder trennen . Achtung! Nach dem Herstellen der Spannungsversorgung schaltet das Gerät verzögert ein. Warten Sie vor der Inbetriebnahme min. 2 Sekunden. Anschließbare Komponenten optional 11 12 13 13 14 15 1. CU170 2. RF1058 3. M1: z.B. DELTADRIVE DS2 4. M2: z.B. DELTADRIVE DZ 5. M3: z.B. DELTADRIVE DZ 6. M4: z.B. DELTADRIVE DZ 7. POWER SUPPLY PD12 8. Netzzuleitung US Version 9. Massagemotor 10. Verteilerkabel (2x Massagemotor) 11. Optional: POWER DOWN BOX 10 12. Optional: LED-Set mit POWER BOX 14. Optional: USB SOCKET optional 13. Optional: Massagemotor 16 15. Optional: USB CHARGER 17 16. Optional: Verteilerkabel 17. Optional: Adapterkabel 18 19 18. Optional: Verteilerkabel 19. Optional: Synchronkabel 03.04.2017 Id-Nr. 84625(c) 7 / 12 Kurzanleitung RF1058 / CU170 CU170 Anschlüsse und Funktionen 1. Anschluss für (POWER SUPPLY PD12, M1 und M2) 2. Anschlussbuchse für M3 3. Anschlussbuchse für M4 4. Anschlussbuchse für Massagemotor 5. Multifunktions Port für optionales Zubehör 6. Reset-Taste / Pairing-Taste (Pairing LED) Technische Daten 03.04.2017 Id-Nr. 84625(c) Eingangsspannung 24-29V DC Stromaufnahme max. 6.00A Betriebsart Aussetzbetrieb AB 2 min. / 18 min. Schutzklasse III Schutzart IP20 Länge x Breite x Höhe 186mm x 120mm x 38mm Transport-/Lagertemperatur von -20°C bis +50°C Betriebstemperatur von +10°C bis +40°C Relative Luftfeuchte von 30% bis 75% Luftdruck von 800hPa bis 1060hPa Höhe < 2000m 8 / 12 Kurzanleitung RF1058 / CU170 Handsender RF1058 Taste 11 10 14 13 17 16 19 12 15 18 21 20 10 11 12 13 14 15 16 17 18 19 20 21 1 + 19 3 + 19 13 + 15 16 + 19 16 + 19 LED 03.04.2017 Quittierung: Ein erfolgreicher Abschluss des jeweiligen Vorgangs wird durch Funktion Antrieb M1 auf (Kopf) Antrieb M3 auf (Lift) Antrieb M2 auf (Fuß) Antrieb M1 ab (Kopf) Antrieb M3 ab (Lift) Antrieb M2 ab (Fuß) Antrieb M4 auf (Tilt) Antrieb M4 ab (Tilt) Massageintensität + (Kopf) Massage ein/aus Massageintensität + (Fuß) Massageintensität - (Kopf) Massage WAVE wechseln Massageintensität - (Fuß) Memoryspeichertaste (SET) Unterbettbeleuchtung ein/aus Kindersicherung ein/aus Position (Flat) Memoryposition (Zero G) Memoryposition (TV) Pairing System 1 Pairing System 2 Press + Release Press + Hold Werkseinstellung zurückstellen Massagefunktion langsam mittel schnell 2x blinken der UBB und ein „Piep“ Signal. signalisiert. 1. Handsender/App anlernen Zur Inbetriebnahme des RF1058 und eines Bluetooth® Gerät muss die Funkkommunikation mit der CU170 aufgebaut werden. Für das Verfahren Ihres Systems mit einem Bluetooth® Gerät (z.B: Smartphone / Tablet), laden Sie die „OKIN“ App von der entsprechenden Plattform herunter und installieren diese auf Ihrem Gerät. a. Automatisch anlernen Stecken Sie den Stecker der Spannungsversorgung in die Steckdose. Die CU170 befindet sich für 120sec im Pairing Modus, der teilt sich wie folgt auf: In den ersten 60sec kann ein RF1058 angelernt werden, in den zweiten 60sec ein Bluetooth® Gerät. Während der Anlernphase des RF1058 leuchten die UBB und die blaue LED. RF1058: Betätigen Sie gleichzeitig die Tasten 1 + 19. Ein erfolgreicher Abschluss wird quittiert. Nach Beendigung des Anlernvorgangs für den RF1058 erlischt die UBB. Die blaue LED zum Anlernen eines Bluetooth® Gerätes beginnt zu blinken. Ist das Anlernen für Bluetooth® Geräte abgelaufen oder ein Gerät verbunden, erlischt die blaue LED. Ein erfolgreicher Abschluss wird quittiert. Drücken Sie während der Anlernphase für den RF1058 an einem bereits angemeldeten RF1058 eine beliebige Taste, wird auf den Bluetooth® Anlernmodus gewechselt. Sind der RF1058 bzw. ein Bluetooth® Gerät innerhalb der Pairing Phase angelernt, wird der Pairing Modus automatisch beendet. Die UBB und die blaue LED werden ausgeschaltet. Wiederholung vom automatischen Anlernen: Zuerst ziehen Sie den Stecker von der Spannungsversorgung, warten Sie 60sec, und stecken Sie anschließend den Stecker wieder in die Spannungsversorgung. Sie können jetzt mit dem neuen Anlernvorgang beginnen. Bei einem System mit Parallelbetrieb müssen die CU170 nacheinander angelernt werden. 1.te CU170 an die Spannungsversorgung anschließen und den 1.ten RF1058 / Bluetooth® Gerät anlernen, anschließen das 2.te System genauso anlernen. Achtung! Nehmen Sie immer nur ein System, nie mehrere Systeme gleichzeitig in Betrieb. Id-Nr. 84625(c) 9 / 12 Kurzanleitung RF1058 / CU170 b. Manuell einlernen. 3. Das System muss an die Spannungsversorgung angeschlossen sein. Betätigen Sie 2x kurz hintereinander die Reset / Pairing-Taste 6 an der CU170, die UBB und die Pairing LED (grün) leuchten. Die CU170 befindet sich für 120sec im Pairing Modus, der teilt sich wie folgt auf: In den ersten 60sec kann ein RF1058 angelernt werden, in den zweiten 60sec ein Bluetooth® Gerät. Während des Anlernen des RF1058 leuchten die UBB und die blaue LED. RF1058: Betätigen Sie gleichzeitig die Tasten 1 + 19. Ein erfolgreicher Abschluss wird quittiert. Nach Beendigung des Anlernvorgangs für den RF1058 erlischt die UBB. Die blaue LED zum Anlernen eines Bluetooth® Gerätes beginnt zu blinken. Ist das Anlernen für Bluetooth® Geräte abgelaufen oder ein Gerät verbunden, erlischt die blaue LED. Ein erfolgreicher Abschluss wird quittiert. Drücken Sie während der Anlernphase für den RF1058 an einem bereits angemeldeten RF1058 eine beliebige Taste, wird auf den Bluetooth® Anlernmodus gewechselt. Sind der RF1058 bzw. ein Bluetooth® Gerät innerhalb der Pairing Phase angelernt, wird der Pairing Modus automatisch beendet. Die UBB und die blaue LED werden ausgeschaltet. Bei einem System mit Parallelbetrieb müssen die CU170 nacheinander angelernt werden. 1.te CU170 an die Spannungsversorgung anschließen und den 1.ten RF1058 / Bluetooth® Gerät anlernen, anschließend das 2.te System genauso anlernen. Zum Ein- oder Ausschalten der Massage (Kopf und Fußseite) betätigen Sie die Taste 11 auf dem RF1058. Bei ausgeschalteter Massage kann diese mit der Taste 10, Taste 12, Taste 13 oder Taste 15 eingeschaltet werden. Bei eingeschalteter Massage kann diese mit der Taste 13 oder Taste 15, von der kleinsten Intensität ausgehend, ausgeschaltet werden. Die Massageinternsität wird 4 stufig bei jedem Tastendruck auf die Tasten 10, 12, 13 oder 15 geändert. Durch betätigen der WAVE-Taste 14 kann 3 stufig zwischen den verschiedenen Periodendauern gewechselt werden, diese werden durch die LED’s ober-halb der Massagefunktion im RF1058 angezeigt. 4. Erstinbetriebnahme Hardwareänderung Durchführung der elektrischen Rückstellfunktion mit Batteriespannung Die CU170 verfügt über eine Positionsrückmeldung, damit diese reibungslos funktioniert muss zuerst eine Referenzfahrt durchgeführt werden. Betätigen Sie die Reset / Pairing-Taste 6 an der CU170 bis die Endposition angefahren ist. Ein erfolgreicher Abschluss wird quittiert. 5. Handsender RF1058 sperren bzw. freigeben Durch betätigen der Taste 18 (ca. 3 sec halten) wird der RF1058 gesperrt bzw. freigegeben. Ein erfolgreicher Abschluss wird quittiert. 03.04.2017 Referenzfahrt durchführen Es muss eine Referenzfahrt durchführt werden bei, Achtung! Nehmen Sie immer nur ein System, nie mehrere Systeme gleichzeitig in Betrieb. 2. Einstellen der Massageintensität Id-Nr. 84625(c) Memorypositionen speichern Sie können 2 verschiedene Memorypositionen auf den Tasten „ZGRAV / TV“ wie folgt speichern: Fahren Sie die gewünschten Positionen mit den Tasten 1 bis 9 an. Betätigen Sie für 1 sec die Taste 16 (SET). Betätigen Sie innerhalb von 3 sec die Taste 20 (ZGRAV) oder Taste 21 (TV) zum Speichern der Position. Ein erfolgreicher Abschuss wird quittiert. Die gewünschte Position ist jetzt auf den Tasten 20 oder 21 gespeichert. Sie können eine gespeicherte Memoryposition durch Wiederholen des Vorgangs jederzeit überschreiben. 10 / 12 Kurzanleitung RF1058 / CU170 6. Umstellen auf automatisches Fahren und Werkseinstellung 8. Parallelfahrt von zwei Systemen mit Funk Sie können mit den Tasten „FLAT, ZGRAV und TV“ verschiedene, gespeicherte Positionen durch kurzes drücken (Press und Release) anfahren. Die Taste muss dafür nicht festgehalten werden. Hierzu verfahren Sie wie folgt: Achtung! Schließen Sie elektrische Komponenten nur im spannungsfreien Zustand an. Zwei Systeme können im Parallelfahrmodus mit einem RF1058 gleichzeitig verfahren und bedient werden. Aktivierung Fahren Sie mit der Reset / Pairing-Taste 6 der CU170 beide Systeme in die Endposition (untere Endlage der Antriebe). Lernen Sie zuerst System 1 (Taste 1 + 19) an und anschließend System 2 (Taste 3 + 19). Beachten Sie, das immer nur ein System nach dem anderen angelernt wird und nicht 2 Systeme zur gleichen Zeit. Drücken Sie gleichzeitig für ca. 5sec die Taste 13 und Taste 15 der Press + Release Modus ist aktiviert. Ein erfolgreicher Abschuss wird quittiert. Deaktivierung (Werkseinstellung) Drücken Sie gleichzeitig für ca. 5sec die Taste 16 und Taste 19 der Press + Release Modus ist deaktiviert. Der Press + Hold Modus wird aktiviert. Die Memorypositionen von ZGRAV und TV werden auf Werkseinstellung zurückgestellt. Ein erfolgreicher In diesem Modus kann kein 2ter. RF1058 angelernt werden. Abschuss wird quittiert. 7. Parallelfahrt von zwei Systemen mit Synchronkabel Achtung! Schließen Sie elektrische Komponenten nur im spannungsfreien Zustand an. Zwei in Betrieb genommene Systeme können über den Multifunktions-port durch Verwendung eines Synchronkabels miteinander verbunden und gleichzeitig verfahren werden. Fahren Sie mit der Reset / Pairing-Taste 6 der CU170 beide Systeme in die Endposition (untere Endlage der Antriebe). Entfernen Sie die Netzstecker beider Systemen aus der Steckdose. Verbinden Sie beide Systeme mit dem entsprechenden Synchron-kabel am Multifunktionsport. Stecken Sie die Netzstecker beider Systeme in die Steckdose. Ein Parallelbetrieb ist möglich, wenn beide Systeme an der Spannungsversorgung angeschlossen sind. Das Verfahren der Systeme funktioniert mit beiden angelernten Handsendern. 03.04.2017 Id-Nr. 84625(c) 11 / 12 Kurzanleitung RF1058 / CU170 9. Pflege und Reinigung Das System wurde so entworfen, dass dieses einfach zu reinigen ist. Ziehen Sie vor Beginn der Reinigung den Netzstecker der Spannungsversorgung aus der Steckdose! Reinigen Sie das System mit einem trockenen antistatischen Tuch. Achten Sie darauf, bei der Reinigung die Anschlussleitungen nicht zu beschädigen. 10. Entsorgung Das System enthält Elektronikbauteile, Kabel, Metalle, Kunststoffe usw. Das System ist gemäß den geltenden Umweltvorschriften des jeweiligen Landes zu entsorgen. Die Entsorgung des Produkts unterliegt in Deutschland dem Elektro-G, international der EU-Richtlinie 2011/65/EU (RoHS) oder den jeweiligen nationalen Gesetzgebungen. (Das Produkt unterliegt nicht der EU-Richtlinie 2012/19/EU (WEEE)). Das System darf nicht in den Hausmüll gelangen! DewertOkin GmbH Weststraße 1 32278 Kirchlengern Tel: +49 (0)5223/979-0 Fax: +49 (0)5223/75182 http://www.dewertokin.de Info@dewertokin.de 03.04.2017 Id-Nr. 84625(c) 12 / 12
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : No Tagged PDF : Yes XMP Toolkit : Adobe XMP Core 4.0-c321 44.398116, Tue Aug 04 2009 14:24:39 Create Date : 2017:04:03 11:12:56+02:00 Creator Tool : Microsoft® Word 2013 Modify Date : 2017:04:03 11:20:38+02:00 Metadata Date : 2017:04:03 11:20:38+02:00 Format : application/pdf Creator : V.Raab Title : 1 Producer : Microsoft® Word 2013 Document ID : uuid:e34da8de-ba30-404e-8ef7-fe7fd833a71b Instance ID : uuid:83a20ad8-6b3a-48a7-867d-ffba2fd8ec6e Page Count : 12 Language : de-DE Author : V.RaabEXIF Metadata provided by EXIF.tools