Document TitleDigi XBee3 Cellular LTE Cat 1 Smart Modem User Guide
Document Author: Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide

Digi XBee3® Cellular LTE Cat 1
Smart Modem
User Guide
Revision history—90002253
Revision
Date
Description
January 2018
Initial release of the document.
Trademarks and copyright
Digi, Digi International, and the Digi logo are trademarks or registered trademarks in the United
States and other countries worldwide. All other trademarks mentioned in this document are the
property of their respective owners.
© 2018 Digi International Inc. All rights reserved.
Disclaimers
Information in this document is subject to change without notice and does not represent a
commitment on the part of Digi International. Digi provides this document “as is,” without warranty of
any kind, expressed or implied, including, but not limited to, the implied warranties of fitness or
merchantability for a particular purpose. Digi may make improvements and/or changes in this manual
or in the product(s) and/or the program(s) described in this manual at any time.
Warranty
To view product warranty information, go to the following website:
www.digi.com/howtobuy/terms
Send comments
Documentation feedback: To provide feedback on this document, send your comments to
techcomm@digi.com.
Customer support
Digi Technical Support: Digi offers multiple technical support plans and service packages to help our
customers get the most out of their Digi product. For information on Technical Support plans and
pricing, contact us at +1 952.912.3444 or visit us at www.digi.com/support.
Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide
Contents
Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide
Applicable firmware and hardware
SIM cards
Getting started with the XBee Smart Modem Development Kit
Identify the kit contents
XBIB-U-DEV reference
Cellular service
Connect the hardware
Configure the device using XCTU
Add a device
Check for cellular registration and connection
Update to the latest firmware
Send an SMS message to a phone
Debugging
Connect to the ELIZA server
Debugging
Connect to the echo server
Debugging
Connect to the Daytime server
Debugging
Connect to a TCP/IP address
Debugging
Perform a (GET) HTTP request
Debugging
Get started with MQTT
Example: MQTT connect
Send a connect packet
Example: send messages (publish) with MQTT
Example: receive messages (subscribe) with MQTT
Use MQTT over the XBee Cellular Modem with a PC
Get started with CoAP
CoAP terms
CoAP quick start example
Configure the device
Example: manually perform a CoAP request
Example: use Python to generate a CoAP message
Configure the XBee Smart Modem using Digi Remote Manager
Create a Remote Manager account
Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide
11
12
13
14
15
15
16
16
18
19
20
21
22
23
24
25
26
27
28
29
30
30
32
34
34
35
39
39
39
40
40
41
44
44
Get the XBee Smart Modem IMEI number
Add a XBee Smart Modem to Remote Manager
Update the firmware
Software libraries
44
44
45
45
Get started with MicroPython
About MicroPython
Why use MicroPython
MicroPython on the XBee Smart Modem
Use XCTU to enter the MicroPython environment
Use the MicroPython Terminal in XCTU
Example: hello world
Example: turn on an LED
Example: code a request help button
Enter MicroPython paste mode
Catch a button press
Send a text (SMS) when the button is pressed
Add the time the button was pressed
Exit MicroPython mode
Other terminal programs
Tera Term for Windows
Use picocom in Linux
47
47
47
47
48
48
48
49
50
50
52
53
54
54
54
55
Technical specifications
Interface and hardware specifications
RF characteristics
Networking specifications
Power requirements
Power consumption
Electrical specifications
Regulatory approvals
58
58
58
58
59
59
60
Hardware
Mechanical drawings
Pin signals
Pin connection recommendations
RSSI PWM
SIM card
The Associate LED
62
62
63
64
64
64
Antenna recommendations
Antenna connections
Antenna placement
67
68
Design recommendations
Cellular component firmware upgrades
USB Direct design
Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide
70
70
Power supply considerations
Add a capacitor to the RESET line
Heat considerations and testing
Heat sink guidelines
Add a fan to provide active cooling
70
70
71
71
73
Cellular connection process
Connecting
Cellular network
Data network connection
Data communication with remote servers (TCP/UDP)
Disconnecting
SMS encoding
75
75
75
75
75
76
Modes
Select an operating mode
Transparent operating mode
API operating mode
Bypass operating mode
Enter Bypass operating mode
Leave Bypass operating mode
Restore cellular settings to default in Bypass operating mode
USB direct mode
Enable USB direct mode
Command mode
Enter Command mode
Send AT commands
Apply command changes
Make command changes permanent
Exit Command mode
78
79
79
79
79
80
80
80
80
80
81
81
82
82
82
Sleep modes
About sleep modes
Normal mode
Pin sleep mode
Cyclic sleep mode
Cyclic sleep with pin wake up mode
Airplane mode
Connected sleep mode
The sleep timer
MicroPython sleep behavior
84
84
84
84
84
84
84
85
85
Serial communication
Serial interface
Serial data
UART data flow
Serial buffers
CTS flow control
RTS flow control
Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide
87
87
87
87
88
88
AT commands
MicroPython commands
PS (Python Startup)
PY (MicroPython Command)
Special commands
AC (Apply Changes)
FR (Force Reset)
RE command
WR command
Cellular commands
PH (Phone Number)
S# (ICCID)
IM (IMEI)
MN (Operator)
MV (Modem Firmware Version)
DB (Cellular Signal Strength)
AN (Access Point Name)
OA (Operating APN)
AM (Airplane Mode)
DV (Antenna Diversity)
Network commands
IP (IP Protocol)
TL (SSL/TLS Protocol Version)
TM (IP Client Connection Timeout)
TS (IP Server Connection Timeout)
DO (Device Options)
EQ (Device Cloud FQDN)
Addressing commands
SH (Serial Number High)
SL (Serial Number Low)
DL (Destination Address)
P# (Destination Phone Number)
N1 (DNS Address)
N2 (DNS Address)
DE (Destination Port)
TD (Text Delimiter)
MY (Module IP Address)
LA (Lookup IP Address of FQDN)
OD (Operating Destination Address)
C0 (Source Port)
Serial interfacing commands
BD (Baud Rate)
NB (Parity)
SB (Stop Bits)
RO (Packetization Timeout)
FT (Flow Control Threshold)
AP (API Enable)
I/O settings commands
D0 (DIO0/AD0)
D1 (DIO1/AD1)
D2 (DIO2/AD2)
D3 (DIO3/AD3)
D4 (DIO4)
D5 (DIO5/ASSOCIATED_INDICATOR)
Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide
90
90
90
91
91
91
92
92
92
92
92
93
93
93
93
93
94
94
94
95
95
95
95
96
96
96
97
97
97
97
97
98
98
98
98
99
99
99
99
100
100
101
101
101
101
102
102
102
103
103
104
104
105
D6 (DIO6/RTS)
D7 (DIO7/CTS)
D8 (DIO8/SLEEP_REQUEST)
P0 (DIO10/PWM0 Configuration)
P1 (DIO11/PWM1 Configuration)
P2 (DIO12 Configuration)
PD (Pull Direction)
PR (Pull-up/down Resistor Enable)
M0 (PWM0 Duty Cycle)
I/O sampling commands
TP (Temperature)
Sleep commands
SM (Sleep Mode)
SP (Sleep Period)
ST (Wake Time)
SO (Sleep Options)
Command mode options
CC (Command Sequence Character)
CT (Command Mode Timeout)
GT (Guard Times)
Firmware version/information commands
VR (Firmware Version)
VL (Verbose Firmware Version)
HV (Hardware Version)
AI (Association Indication)
HS (Hardware Series)
CK (Configuration CRC)
Diagnostic interface commands
DI (Device Cloud Indicator)
CI (Protocol/Connection Indication)
Execution commands
NR (Network Reset)
!R (Modem Reset)
IS (Force Sample)
105
105
106
107
107
108
108
109
109
110
110
110
110
111
111
111
112
112
112
112
112
112
113
113
113
114
114
114
114
114
116
116
117
117
Operate in API mode
API mode overview
Use the AP command to set the operation mode
API frame format
API operation (AP parameter = 1)
API operation with escaped characters (AP parameter = 2)
Frame descriptions
AT Command - 0x08
Transmit (TX) SMS - 0x1F
Transmit (TX) Request: IPv4 - 0x20
AT Command Response - 0x88
Transmit (TX) Status - 0x89
Modem Status - 0x8A
Receive (RX) Packet: SMS - 0x9F
Receive (RX) Packet: IPv4 - 0xB0
Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide
120
120
120
120
121
124
124
125
126
127
128
129
130
131
Socket behavior
Supported sockets
Secure Sockets Layer (SSL) certificate checking
Socket timeouts
Socket limits in API mode
Enable incoming TCP connections
API mode behavior for outgoing TCP and SSL connections
API mode behavior for outgoing UDP data
API mode behavior for incoming TCP connections
API mode behavior for incoming UDP data
Transparent mode behavior for outgoing TCP and SSL connections
Transparent mode behavior for outgoing UDP data
Transparent mode behavior for incoming TCP connections
Transparent mode behavior for incoming UDP connections
133
133
133
133
133
134
134
135
135
135
136
136
136
Troubleshooting
Cannot find the serial port for the device
Condition
Solution
Correct a macOS Java error
Condition
Solution
Unresponsive cellular component in Bypass mode
Condition
Solution
Not on expected network after APN change
Condition
Solution
Syntax error at line 1
Solution
Error Failed to send SMS
Solution
138
138
138
140
140
140
141
141
141
142
142
142
142
142
142
142
Regulatory information
Modification statement
Interference statement
FCC Class B digital device notice
RF exposure
FCC-approved antennas
Bluetooth antennas
Dipole antennas
Flex PCB antennas
Cellular antennas
Labeling requirements for the host device
Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide
144
144
144
145
145
145
145
145
146
146
Digi XBee3 Cellular LTE Cat 1 Smart Modem User
Guide
The XBee Smart Modem is an embedded Long-Term Evolution (LTE) Category 1 cellular module that
provides original equipment manufacturers (OEMs) with a simple way to integrate cellular
connectivity into their devices.
The XBee Smart Modem enables OEMs to quickly integrate cutting edge 4G cellular technology into
their devices and applications without dealing with the painful, time-consuming, and expensive FCC
and carrier end-device certifications.
With the full suite of standard XBee API frames and AT commands, existing XBee customers can
seamlessly transition to this new device with only minor software adjustments. When OEMs add the
XBee Smart Modem to their product, they create a future-proof design with flexibility to switch
between wireless protocols or frequencies as needed.
You can read some frequently asked questions here.
Applicable firmware and hardware
This manual supports the following firmware:
n 310xx
It supports the following hardware:
n XB3-C-A1-UT-xxx
SIM cards
The XBee Smart Modem requires a 4FF (Nano) size SIM card. The SIM interface supports both 1.8 V
and 3 V SIM types.
Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide
Getting started with the XBee Smart Modem
Development Kit
This section describes how to connect the hardware in the XBee Smart Modem Development Kit, and
provides some examples you can use to communicate with the device.
Identify the kit contents
XBIB-U-DEV reference
Cellular service
Connect the hardware
Configure the device using XCTU
Send an SMS message to a phone
Connect to the ELIZA server
Connect to the echo server
Connect to the Daytime server
Connect to a TCP/IP address
Perform a (GET) HTTP request
Get started with MQTT
Get started with CoAP
Configure the XBee Smart Modem using Digi Remote Manager
Software libraries
Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide
11
12
13
14
15
18
20
22
24
26
28
30
39
44
45
10
Getting started with the XBee Smart Modem Development Kit
Identify the kit contents
Identify the kit contents
The Developer's kit includes the following:
One XBIB-U-DEV board
One 12 V power supply
Two cellular antennas with U.FL connectors
One USB cable
One XBee Smart Modem
One SIM card
Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide
11
Getting started with the XBee Smart Modem Development Kit
XBIB-U-DEV reference
XBIB-U-DEV reference
This picture shows the XBee USB development board and the table that follows explains the callouts
in the picture.
Number Item
Description
Programming header Header used to program XBee Programmable devices.
Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide
12
Getting started with the XBee Smart Modem Development Kit
Cellular service
Number Item
Description
Advanced users only—voids the warranty. Depopulate R31 to
power the device using V+ and GND from J2 and J5. You can
connect sense lines to S+ and S- for sensing power supplies.
Self power module
CAUTION: Voltage is not regulated. Applying the incorrect
voltage can cause fire and serious injury.1
Current testing
Depopulating R31 allows a current probe to be inserted across P6
terminals. The current though P6/R31 powers the device only.
Other supporting circuitry is powered by a different trace.
Loopback jumper
Populating P8 with a loopback jumper causes serial transmissions
both from the device and from the USB to loopback.
DC barrel plug: 6-20 V Greater than 500 mA loads require a DC supply for correct
operation. Plug in the external power supply prior to the USB
connector to ensure that proper USB communications are not
interrupted.
LED indicator
USB
RSSI indicator
User buttons
10
Reset button
11
SPI power
Connect to the power board from 3.3 V.
12
SPI
Only used for surface-mount devices.
13
Indicator LEDs
DS5: ON/SLEEP
DS2: DIO12, the LED illuminates when driven low.
DS3: DIO11, the LED illuminates when driven low.
DS4: DIO4, the LED illuminates when driven low.
14
Through-hole XBee
sockets
15
20-pin header
Yellow: Modem sending serial/UART data to host.
Green: Modem receiving serial/UART data from host.
Red: Associate.
Connected to DIO lines for user implementation.
Maps to standard through-hole XBee pins.
Cellular service
The XBee Cellular kit includes six months of free cellular service.
1Powering the board with J2 and J5 without R31 removed can cause shorts if the USB or barrel plug power are
connected. Applying too high a voltage destroys electronic circuitry in the device and other board components
and/or can cause injury.
Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide
13
Getting started with the XBee Smart Modem Development Kit
Connect the hardware
Connect the hardware
1. The XBee Smart Modem should already be plugged into the XBIB-U-DEV board.
2. The SIM card should be already be inserted into the XBee Smart Modem. If not, install the
SIM card into the XBee Smart Modem.
WARNING! Never insert or remove the SIM card while the device is powered!
3. Connect the antennas to the XBee Smart Modem by aligning the U.FL connectors carefully,
then firmly pressing straight down to seat the connector. You should hear a snap when the
antenna attaches correctly. U.FL is fragile and is not designed for multiple insertions, so
exercise caution when connecting or removing the antennas. We recommend using a U.FL
removal tool.
4. Plug the 12 V power supply to the power jack on the development board.
Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide
14
Getting started with the XBee Smart Modem Development Kit
Configure the device using XCTU
5. Connect the USB cable from a PC to the USB port on the development board. The computer
searches for a driver, which can take a few minutes to install.
Configure the device using XCTU
XBee Configuration and Test Utility (XCTU) is a multi-platform program that enables users to interact
with Digi radio frequency (RF) devices through a graphical interface. The application includes built-in
tools that make it easy to set up, configure, and test Digi RF devices.
XCTU does not work directly over an SPI interface.
For instructions on downloading and using XCTU, see the XCTU User Guide.
Note If you are on a macOS computer and encounter problems installing XCTU, see Correct a macOS
Java error.
Add a device
These instructions show you how to add the XBee Smart Modem to XCTU. If XCTU does not find your
serial port, see Cannot find the serial port for the device.
1. Launch XCTU
2. Click the Discover radio modules button
3. In the Discover radio devices dialog, select the serial ports where you want to look for XBee
modules, and click Next.
4. In the Set port parameters window, maintain the default values and click Finish.
5. As XCTU locates radio modules, they appear in the Discovering radio modules dialog box.
If your module could not be found, XCTU displays the Could not find any radio module dialog
providing possible reasons why the module could not be added.
Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide
15
Getting started with the XBee Smart Modem Development Kit
Configure the device using XCTU
Check for cellular registration and connection
In the following examples, proper cellular network registration and address assignment must occur
successfully. The LED on the development board blinks when the XBee Smart Modem is registered to
the cellular network; see The Associate LED. If the LED remains solid, registration has not occurred
properly. Registration can take several minutes.
Note Make sure you are in an area with adequate cellular network reception or the XBee Smart
Modem will not make the connection.
In addition to the LED confirmation, you can check the AT commands below in XCTU to check the
registration and connection. To view these commands:
1. Open XCTU and Add a device.
2. Click the Configuration working mode
button.
3. Select a device from the Radio Modules list. XCTU displays the current firmware settings for
that device.
4. On the Configuration toolbar, click the Default button
to load the default values
established by the firmware, and click Yes to confirm.
The relevant commands are:
n AI (Association Indication) reads zero when the device successfully registers to the cellular
network. If it reads 0x23 it is connecting to the Internet; 0x22 means it is registering to the
cellular network.
MY (Module IP Address) should display a valid IP address. If it reads 0.0.0.0, it has not
registered yet.
Note To search for an AT command in XCTU, use the search box.
Update to the latest firmware
Firmware is the program code stored in the device's persistent memory that provides the control
program for the device. Use XCTU to update the firmware.
1. Click the Configuration working modes button
2. Select a local XBee module from the Radio Modules list.
3. Click the Update firmware button
The Update firmware dialog displays the available and compatible firmware for the selected
XBee module.
4. Select the product family of the XBee module, the function set, and the latest firmware version.
Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide
16
Getting started with the XBee Smart Modem Development Kit
Configure the device using XCTU
5. Click Update. A dialog displays update progress. Click Show details for details of the firmware
update process.
See How to update the firmware of your modules in the XCTU User Guide for more information.
Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide
17
Getting started with the XBee Smart Modem Development Kit
Send an SMS message to a phone
Send an SMS message to a phone
The XBee Smart Modem can send and receive Short Message Service (SMS) transmissions (text
messages) while in Transparent mode. This allows you to send and receive text messages to and from
an SMS capable device such as a mobile phone.
The following table explains the AT commands that you use in this example.
Command
Value
Description
AP (API Enable)
Set the device's API mode to Transparent mode.
IP (IP Protocol)
Set the expected transmission mode to SMS communication.
P#
 on using this command.
TD (Text Delimiter) D (0x0D)
The text delimiter to be used for Transparent mode, as an ASCII hex
code. No information is sent until this character is entered, unless
the maximum number of characters has been reached. Set to zero
to disable text delimiter checking. Set to D for a carriage return.
PH (Module's SIM
phone number)
The value that represents your device's phone number as supplied
by the SIM card. This is used to send text messages to the device
from another cellular device.
Read
only
1. Ensure that the device is set up correctly with the SIM card installed and the antennas
connected as described in Connect the hardware.
2. Open XCTU and Add a device.
3. Click the Configuration working mode
button.
4. Select a device from the Radio Modules list. XCTU displays the current firmware settings for
that device.
5. To switch to SMS communication, in the IP field, select 2 and click the Write button
6. To enter your cell phone number, in the P# field, type the  and click
the Write button. Type the phone number using only numbers, with no dashes. You can use the
+ prefix if necessary. The target phone number is the phone number you wish to send a text to.
7. In the TD field, type D and click the Write button.
8. Note the number in the PH field; it is the XBee Smart Modem phone number, which you see
when it sends an SMS to your phone.
Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide
18
Getting started with the XBee Smart Modem Development Kit
9. Click the Consoles working mode button
Send an SMS message to a phone
on the toolbar to open a serial console to the
device. For instructions on using the Console, see the AT console topic in the XCTU User Guide.
10. Click the Open button
to open a serial connection to the device.
11. Click in the left pane of the Console log, type hello world and press Enter. The XBee Smart
Modem sends the message to the destination phone number set by the P# command.
12. When the phone receives the text, you can see that the sender's phone number matches the
value reported by the XBee Smart Modem with the PH command.
13. On the phone, reply with the text connect with confidence and the XBee Smart Modem
outputs this reply from the UART.
Debugging
If you experience problems with the settings in this example, you can load the default settings in
XCTU:
1. On the Configuration toolbar, click the Default button
to load the default values
established by the firmware, and click Yes to confirm.
2. Factory settings are loaded but not written to the device. To write them, click the Write button
on the toolbar.
Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide
19
Getting started with the XBee Smart Modem Development Kit
Connect to the ELIZA server
Connect to the ELIZA server
You can use the XBee Smart Modem to chat with the ELIZA Therapist Bot. ELIZA is an artificial
intelligence (AI) bot that emulates a therapist and can perform simple conversations.
The following table explains the AT commands that you use in this example.
At command
Value
Description
IP (IP Protocol)
Set the expected transmission mode to TCP
communications.
DL (Destination
Address)
52.43.121.77 The target IP address of the Eliza server.
DE (Destination Port)
0x2328
The target port number of the Eliza server.
To communicate with the ELIZA Therapist Bot:
1. Ensure that the device is set up correctly with the SIM card installed and the antennas
connected as described in Connect the hardware.
2. Open XCTU and Add a device.
3. Click the Configuration working mode
button.
4. Select a device from the Radio Modules list. XCTU displays the current firmware settings for
that device.
5. To switch to TCP communication, in the IP field, select 1 and click the Write button
6. To enter the destination address of the ELIZA Therapist Bot, in the DL field, type 52.43.121.77
and click the Write button.
7. To enter the destination IP port number, in the DE field, type 2328 and click the Write button.
8. Click the Consoles working mode button
on the toolbar to open a serial console to the
device. For instructions on using the Console, see the AT console topic in the XCTU User Guide.
9. Click the Open button
to open a serial connection to the device.
10. Click in the left pane of the Console log, then type in the Console to talk to the ELIZA Therapist
Bot. The following screenshot provides an example of this chat.
Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide
20
Getting started with the XBee Smart Modem Development Kit
Connect to the ELIZA server
Debugging
If you experience problems with the settings in this example, you can load the default settings in
XCTU:
1. On the Configuration toolbar, click the Default button
to load the default values
established by the firmware, and click Yes to confirm.
2. Factory settings are loaded but not written to the device. To write them, click the Write button
on the toolbar.
Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide
21
Getting started with the XBee Smart Modem Development Kit
Connect to the echo server
Connect to the echo server
This server echoes back the messages you type.
The following table explains the AT commands that you use in this example.
At
command
Value
Description
IP (IP
Protocol)
Set the expected transmission mode to TCP communications.
TD (Text
Delimiter)
D (0x0D)
The text delimiter to be used for Transparent mode, as an ASCII hex
code. No information is sent until this character is entered, unless the
maximum number of characters has been reached. Set to zero to
disable text delimiter checking. Set to D for a carriage return.
DL
52.43.121.77 The target IP address of the echo server.
(Destination
Address)
DE
0x2329
(Destination
Port)
The target port number of the echo server.
To communicate with the echo server:
1. Ensure that the device is set up correctly with the SIM card installed and the antennas
connected as described in Connect the hardware.
2. Open XCTU and Add a device.
3. Click the Configuration working mode
button.
4. Select a device from the Radio Modules list. XCTU displays the current firmware settings for
that device.
5. To switch to TCP communication, in the IP field, select 1 and click the Write button
6. To enable the XBee Smart Modem to recognize carriage return as a message delimiter, in the
TD field, type D and click the Write button.
7. To enter the destination address of the echo server, in the DL field, type 52.43.121.77 and click
the Write button.
8. To enter the destination IP port number, in the DE field, type 2329 and click the Write button.
Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide
22
Getting started with the XBee Smart Modem Development Kit
9. Click the Consoles working mode button
Connect to the echo server
on the toolbar to open a serial console to the
device. For instructions on using the Console, see the AT console topic in the XCTU User Guide.
10. Click the Open button
to open a serial connection to the device.
11. Click in the left pane of the Console log, then type in the Console to talk to the echo server.
The following screenshot provides an example of this chat.
Debugging
If you experience problems with the settings in this example, you can load the default settings in
XCTU:
1. On the Configuration toolbar, click the Default button
to load the default values
established by the firmware, and click Yes to confirm.
2. Factory settings are loaded but not written to the device. To write them, click the Write button
on the toolbar.
Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide
23
Getting started with the XBee Smart Modem Development Kit
Connect to the Daytime server
Connect to the Daytime server
The Daytime server reports the current Coordinated Universal Time (UTC) value responding to any
user input.
The following table explains the AT commands that you use in this example.
At
command
IP (IP
Protocol)
Value
Description
Set the expected transmission mode to TCP communications.
DL
52.43.121.77 The target IP of the Daytime server.
(Destination
Address)
DE
0x232A
(Destination
Port)
The target port number of the Daytime server.
TD (Text
Delimiter)
The text delimiter to be used for Transparent mode, as an ASCII hex
code. No information is sent until this character is entered, unless the
maximum number of characters has been reached. Set to zero to
disable text delimiter checking.
To communicate with the Daytime server:
1. Ensure that the device is set up correctly with the SIM card installed and the antennas
connected as described in Connect the hardware.
2. Open XCTU and Add a device.
3. Click the Configuration working mode
button.
4. Select a device from the Radio Modules list. XCTU displays the current firmware settings for
that device.
5. To switch to TCP communication, in the IP field, select 1 and click the Write button
6. To enter the destination address of the daytime server, in the DL field, type 52.43.121.77 and
click the Write button.
7. To enter the destination IP port number, in the DE field, type 232A and click the Write button.
8. To disable text delimiter checking, in the TD field, type 0 and click the Write button.
9. Click the Consoles working mode button
on the toolbar to open a serial console to the
device. For instructions on using the Console, see the AT console topic in the XCTU User Guide.
Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide
24
Getting started with the XBee Smart Modem Development Kit
10. Click the Open button
Connect to the Daytime server
to open a serial connection to the device.
11. Click in the left pane of the Console log, then type in the Console to query the Daytime server.
The following screenshot provides an example of this chat.
Debugging
If you experience problems with the settings in this example, you can load the default settings in
XCTU:
1. On the Configuration toolbar, click the Default button
to load the default values
established by the firmware, and click Yes to confirm.
2. Factory settings are loaded but not written to the device. To write them, click the Write button
on the toolbar.
Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide
25
Getting started with the XBee Smart Modem Development Kit
Connect to a TCP/IP address
Connect to a TCP/IP address
The XBee Smart Modem can send and receive TCP messages while in Transparent mode; see
Transparent operating mode.
You can use this example as a template for sending and receiving data from a user. The following table
explains the AT commands that you use in this example.
Command
Value
Description
IP (IP
Protocol)
Set the expected transmission mode to TCP communication.
DL
(Destination
IP Address)

The target IP address that you send and receive from. For example, a
data logging server’s IP address that you want to send
measurements to.
DE
(Destination
Port)
 This is represented as a hexadecimal value.
To connect to a TCP/IP address:
1. Ensure that the device is set up correctly with the SIM card installed and the antennas
connected as described in Connect the hardware.
2. Open XCTU and Add a device.
3. Click the Configuration working mode
button.
4. Select a device from the Radio Modules list. XCTU displays the current firmware settings for
that device.
5. In the IP field, select 1 and click the Write button
6. In the DL field, type the  and click the Write button. The target IP address
is the IP address that you send and receive from.
7. In the DE field, type the , converted to hexadecimal, and click the Write
button.
8. Exit Command mode; see Exit Command mode.
After exiting Command mode, any UART data sent to the device is sent to the destination IP address
and port number after the RO (Packetization Timeout) occurs.
Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide
26
Getting started with the XBee Smart Modem Development Kit
Connect to a TCP/IP address
Debugging
If you experience problems with the settings in this example, you can load the default settings in
XCTU:
1. On the Configuration toolbar, click the Default button
to load the default values
established by the firmware, and click Yes to confirm.
2. Factory settings are loaded but not written to the device. To write them, click the Write button
on the toolbar.
Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide
27
Getting started with the XBee Smart Modem Development Kit
Perform a (GET) HTTP request
Perform a (GET) HTTP request
You can use the XBee Smart Modem to perform a GET Hypertext Transfer Protocol (HTTP) request
using XCTU. This example uses http://httpbin.org/ as the target website that responds to the HTTP
request.
To perform a GET request:
1. Ensure that the device is set up correctly with the SIM card installed and the antennas
connected as described in Connect the hardware.
2. Open XCTU and Add a device.
3. Click the Configuration working mode
button.
4. Select a device from the Radio Modules list. XCTU displays the current firmware settings for
that device.
5. To enter the destination address of the target website, in the DL field, type httpbin.org and
click the Write button
6. To enter the HTTP request port number, in the DE field, type 50 and click the Write button.
Hexadecimal 50 is 80 in decimal.
7. To switch to TCP communication, in the IP field, select 1 and click the Write button.
8. To move into Transparent mode, in the AP field, select 0 and click the Write button.
9. Wait for the AI (Association Indication) value to change to 0 (Connected to the Internet).
10. Click the Consoles working mode button
on the toolbar.
11. From the AT console, click the Add new packet button
in the Send packets dialog. The
Add new packet dialog appears.
12. Enter the name of the data packet.
13. Type the following data in the ASCII input tab:
GET /ip HTTP/1.1
Host: httpbin.org
14. Click the HEX input tab and add 0A (zero A) after each 0D (zero D), and add an additional 0D 0A
at the end of the message body. For example, copy and past the following text into the HEX
input tab:
47 45 54 20 2F 69 70 20 48 54 54 50 2F 31 2E 31 0D 0A 48 6F 73 74 3A 20 68 74 74 70 62 69 6E
2E 6F 72 67 0D 0A 0D 0A
Note The HTTP protocol requires an empty line (a line with nothing preceding the CRLF) to terminate
the request.
15. Click Add packet.
16. Click the Open button
Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide
28
Getting started with the XBee Smart Modem Development Kit
Perform a (GET) HTTP request
17. Click Send selected packet.
18. A GET HTTP response from httpbin.org appears in the Console log.
Debugging
If you experience problems with the settings in this example, you can load the default settings in
XCTU:
1. On the Configuration toolbar, click the Default button
to load the default values
established by the firmware, and click Yes to confirm.
2. Factory settings are loaded but not written to the device. To write them, click the Write button
on the toolbar.
Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide
29
Getting started with the XBee Smart Modem Development Kit
Get started with MQTT
Get started with MQTT
MQ Telemetry Transport (MQTT) is a messaging protocol that is ideal for the Internet of Things (IoT)
due to a light footprint and its use of the publish-subscribe model. In this model, a client connects to a
broker, a server machine responsible for receiving all messages, filtering them, and then sending
messages to the appropriate clients.
The first two MQTT examples do not involve the XBee Smart Modem. They demonstrate using the
MQTT libraries because those libraries are required for Use MQTT over the XBee Cellular Modem with
a PC.
The examples in this guide assume:
n Some knowledge of Python.
An integrated development environment (IDE) such as PyCharm, IDLE or something similar.
The examples require:
n An XBee Smart Modem.
A compatible development board, such as the XBIB-U.
XCTU. See Configure the device using XCTU.
That you install Python on your computer. You can download Python from:
https://www.python.org/downloads/.
That you install the pyserial and paho-mqtt libraries to the Python environment. If you use
Python 2, install these libraries from the command line with pip install pyserial and pip
install paho-mqtt. If you use Python 3, use pip3 install pyserial and pip3 install paho-mqtt.
The full MQTT library source code, which includes examples and tests, which is available in the
paho-mqtt github repository at https://github.com/eclipse/paho.mqtt.python. To download this
repository you must have Git installed.
Example: MQTT connect
This example provides insight into the structure of packets in MQTT as well as the interaction
between the client and broker. MQTT uses different packets to accomplish tasks such as connecting,
subscribing, and publishing. You can use XCTU to perform a basic example of sending a broker a
connect packet and receiving the response from the server, without requiring any coding. This is a
good way to see how the client interacts with the broker and what a packet looks like. The following
table is an example connect packet:
Description
Hex value
CONNECT packet fixed header
byte 1
Control packet type
0x10
byte 2
Remaining length
0x10
CONNECT packet variable header
Protocol name
Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide
30
Getting started with the XBee Smart Modem Development Kit
Get started with MQTT
Description
Hex value
byte 1
Length MSB (0)
0x00
byte 2
Length LSB (4)
0x04
byte 3
(M)
0x4D
byte 4
(Q)
0x51
byte 5
(T)
0x54
byte 6
(T)
0x54
Level (4)
0x04
CONNECT flags byte, see the table below for the bits.
0X02
byte 9
Keep Alive MSB (0)
0X00
byte 10
Keep Alive LSB (60)
0X3C
byte 11
Length MSB (0)
0x00
byte 12
Length LSB (4)
0x04
byte 13
(D)
0x44
byte 14
(I)
0x49
byte 15
(G)
0x47
byte 16
(I)
0x49
Protocol level
byte 7
Connect flags
byte 8
Keep alive
Client ID
The following table describes the fields in the packet:
Field name
Description
Protocol Name The connect packet starts with the protocol name, which is MQTT. The length of
the protocol name (in bytes) is immediately before the name itself.
Protocol Level
Refers to the version of MQTT in use, in this case a value of 4 indicates MQTT
version 3.1.1.
Connect Flags
Indicate certain aspects of the packet. For simplicity, this example only sets the
Clean Session flag, which indicates to the client and broker to discard any previous
session and start a new one.
Keep Alive
How often the client pings the broker to keep the connection alive; in this example
it is set to 60 seconds.
Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide
31
Getting started with the XBee Smart Modem Development Kit
Get started with MQTT
Field name
Description
Client ID
The length of the ID (in bytes) precedes the ID itself. Each client connecting to a
broker must have a unique client ID. In the example, the ID is DIGI. When using the
Paho MQTT Python libraries, a random alphanumeric ID is generated if you do not
specify an ID.
The following table provides the CONNECT flag bits from byte 8, the CONNECT flags byte.
CONNECT Flag Bit(s)
Bit 7
User name flag
Password flag
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
Will retain
Will QoS
Will flag
Clean session
Reserved
Send a connect packet
Now that you know what a connect packet looks like, you can send a connect packet to a broker and
view the response. Open XCTU and click the Configuration working mode button.
1. Ensure that the device is set up correctly with the SIM card installed and the antennas
connected as described in Connect the hardware.
2. Open XCTU and click the Configuration working mode
button.
3. Add the XBee Smart Modem to XCTU; see Add a device.
4. Select a device from the Radio Modules list. XCTU displays the current firmware settings for
that device.
5. In the AP field, set Transparent Mode to [0] if it is not already and click the Write button.
6. In the DL field, type the IP address of the broker you wish to use. This example uses
198.41.30.241, which is the IP address for m2m.eclipse.org, a public MQTT broker.
7. In the DE field, type 75B and set the port that the broker uses. This example uses 75B, because
the default MQTT port is 1883 (0x75B).
8. Once you have entered the required values, click the Write button to write the changes to the
XBee Smart Modem.
Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide
32
Getting started with the XBee Smart Modem Development Kit
9. Click the Consoles working mode button
Get started with MQTT
on the toolbar to open a serial console to the
device. For instructions on using the Console, see the AT console topic in the XCTU User Guide.
10. Click the Open button
to open a serial connection to the device.
11. From the AT console, click the Add new packet button
in the Send packets dialog. The
Add new packet dialog appears.
12. Enter the name of the data packet. Name the packet connect_frame or something similar.
13. Click the HEX input tab and type the following (these values are the same values from the
table in Example: MQTT connect):
10 10 00 04 4D 51 54 54 04 02 00 3C 00 04 44 49 47 49
14. Click Add packet. The new packet appears in the Send packets list.
15. Click the packet in the Send packets list.
16. Click Send selected packet.
17. A CONNACK packet response from the broker appears in the Console log. This is a connection
acknowledgment; a successful response should look like this:
Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide
33
Getting started with the XBee Smart Modem Development Kit
Get started with MQTT
You can verify the response from the broker as a CONNACK by comparing it to the structure of a
CONNACK packet in the MQTT documentation, which is available at http://docs.oasisopen.org/mqtt/mqtt/v3.1.1/os/mqtt-v3.1.1-os.html#_Toc398718081).
Example: send messages (publish) with MQTT
A basic Python example of a node publishing (sending) a message is:
mqttc = mqtt.Client("digitest") # Create instance of client with client ID
“digitest”
mqttc.connect("m2m.eclipse.org", 1883) # Connect to (broker, port,
keepalive-time)
mqttc.loop_start() # Start networking daemon
mqttc.publish("digitest/test1", "Hello, World!") # Publish message to
“digitest /test1” topic
mqttc.loop_stop() # Kill networking daemon
Note You can easily copy and paste code from the online version of this Guide. Use caution with the
PDF version, as it may not maintain essential indentations.
This example imports the MQTT library, allowing you to use the MQTT protocol via APIs in the library,
such as the connect(), subscribe(), and publish() methods.
The second line creates an instance of the client, named mqttc. The client ID is the argument you
passed in: digitest (this is optional).
In line 3, the client connects to a public broker, in this case m2m.eclipse.org, on port 1883 (the default
MQTT port, or 8883 for MQTT over SSL). There are many publicly available brokers available, you can
find a list of them here: https://github.com/mqtt/mqtt.github.io/wiki/brokers.
Line 4 starts the networking daemon with client.loop_start() to handle the background
network/data tasks.
Finally, the client publishes its message Hello, World! to the broker under the topic
digitest/backlog/test1. Any nodes (devices, phones, computers, even microcontrollers) subscribed to
that same topic on the same broker receive the message.
Once no more messages need to be published, the last line stops the network daemon with
client.loop_stop().
Example: receive messages (subscribe) with MQTT
This example describes how a client would receive messages from within a specific topic on the
broker:
import paho.mqtt.client as mqtt
def on_connect(client, userdata, flags, rc): # The callback for when the
client connects to the broker
print("Connected with result code {0}".format(str(rc))) # Print result
of connection attempt
client.subscribe("digitest/test1") # Subscribe to the topic
“digitest/test1”, receive any messages published on it
def on_message(client, userdata, msg): # The callback for when a PUBLISH
message is received from the server.
print("Message received-> " + msg.topic + " " + str(msg.payload)) #
Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide
34
Getting started with the XBee Smart Modem Development Kit
Get started with MQTT
Print a received msg
client = mqtt.Client("digi_mqtt_test") # Create instance of client with
client ID “digi_mqtt_test”
client.on_connect = on_connect # Define callback function for successful
connection
client.on_message = on_message # Define callback function for receipt of a
message
# client.connect("m2m.eclipse.org", 1883, 60) # Connect to (broker, port,
keepalive-time)
client.connect('127.0.0.1', 17300)
client.loop_forever() # Start networking daemon
Note You can easily copy and paste code from the online version of this Guide. Use caution with the
PDF version, as it may not maintain essential indentations.
The first line imports the library functions for MQTT.
The functions on_connect and on_message are callback functions which are automatically called by
the client upon connection to the broker and upon receiving a message, respectively.
The on_connect function prints the result of the connection attempt, and performs the subscription.
It is wise to do this in the callback function as it guarantees the attempt to subscribe happens only
after the client is connected to the broker.
The on_message function prints the received message when it comes in, as well as the topic it was
published under.
In the body of the code, we:
n Instantiate a client object with the client ID digi_mqtt_test
Define the callback functions to use upon connection and upon message receipt
Connect to an MQTT broker at m2m.eclipse.org, on port 1883 (the default MQTT port, or 8883
for MQTT over SSL) with a keepalive of 60 seconds (this is how often the client pings the broker
to keep the connection alive).
The last line starts a network daemon that runs in the background and handles data transactions and
messages, as well as keeping the socket open, until the script ends.
Use MQTT over the XBee Cellular Modem with a PC
To use this MQTT library over an XBee Smart Modem, you need a basic proxy that transfers a payload
received via the MQTT client’s socket to the serial or COM port that the XBee Smart Modem is active
on, as well as the reverse; transfer of a payload received on the XBee Smart Modem’s serial or COM
port to the socket of the MQTT client. This is simplest with the XBee Smart Modem in Transparent
mode, as it does not require code to parse or create API frames, and not using API frames means
there is no need for them to be queued for processing.
1. To put the XBee Cellular Modem in Transparent mode, set AP to 0.
2. Set DL to the IP address of the broker you want to use.
3. Set DE to the port to use, the default is 1883 (0x75B). This sets the XBee Smart Modem to
communicate directly with the broker, and can be performed in XCTU as described in Example:
MQTT connect.
4. You can make the proxy with a dual-threaded Python script, a simple version follows:
Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide
35
Getting started with the XBee Smart Modem Development Kit
Get started with MQTT
import threading
import serial
import socket
def setup():
"""
This function sets up the variables needed, including the serial port,
and it's speed/port settings, listening socket, and localhost adddress.
"""
global clisock, cliaddr, svrsock, ser
# Change this to the COM port your XBee Cellular module is using. On
# Linux, this will be /dev/ttyUSB#
comport = 'COM44'
# This is the default serial communication speed of the XBee Cellular
# module
comspeed = 115200
buffer_size = 4096 # Default receive size in bytes
debug_on = 0 # Enables printing of debug messages
toval = None # Timeout value for serial port below
# Serial port object for XBCell modem
ser = serial.Serial(comport,comspeed,timeout=toval)
# Listening socket (accepts incoming connection)
svrsock = socket.socket(socket.AF_INET,socket.SOCK_STREAM)
# Allow address reuse on socket (eliminates some restart errors)
svrsock.setsockopt(socket.SOL_SOCKET, socket.SO_REUSEADDR, 1)
clisock = None
cliaddr = None # These are first defined before thread creation
addrtuple = ('127.0.0.1', 17300) # Address tuple for localhost
# Binds server socket to localhost (allows client program connection)
svrsock.bind(addrtuple)
svrsock.listen(1) # Allow (1) connection
def ComReaderThread():
"""
This thread listens on the defined serial port object ('ser') for data
from the modem, and upon receipt, sends it out to the client over the
client socket ('clisock').
"""
global clisock
while (1):
resp = ser.read() ## Read any available data from serial port
print("Received {} bytes from modem.".format(len(resp)))
clisock.sendall(resp) # Send RXd data out on client socket
print("Sent {} byte payload out socket to client.".format(len
(resp)))
def SockReaderThread():
"""
This thread listens to the MQTT client's socket and upon receiving a
payload, it sends this data out on the defined serial port ('ser') to
the
modem for transmission.
"""
global clisock
Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide
36
Getting started with the XBee Smart Modem Development Kit
Get started with MQTT
while (1):
data = clisock.recv(4096) # RX data from client socket
# If the RECV call returns 0 bytes, the socket has closed
if (len(data) == 0):
print("ERROR - socket has closed. Exiting socket reader
thread.")
return 1 # Exit the thread to avoid a loop of 0-byte receptions
else:
print("Received {} bytes from client via socket.".format(len
(data)))
print("Sending payload to modem...")
bytes_wr = ser.write(data) # Write payload to modem via
UART/serial
print("Wrote {} bytes to modem".format(bytes_wr))
def main():
setup() # Setup the serial port and socket
global clisock, svrsock
if (not clisock): # Accept a connection on 'svrsock' to open 'clisock'
print("Awaiting ACCEPT on server sock...")
(clisock,cliaddr) = svrsock.accept() # Accept an incoming
connection
print("Connection accepted on socket")
# Make thread for ComReader
comthread = threading.Thread(target=ComReaderThread)
comthread.start() # Start the thread
# Make thread for SockReader
sockthread = threading.Thread(target=SockReaderThread)
sockthread.start() # Start the thread
main()
Note This script is a general TCP-UART proxy, and can be used for other applications or scripts that
use the TCP protocol. Its functionality is not limited to MQTT.
Note You can easily copy and paste code from the online version of this Guide. Use caution with the
PDF version, as it may not maintain essential indentations.
This proxy script waits for an incoming connection on localhost (127.0.0.1), on port 17300. After
accepting a connection, and creating a socket for that connection (clisock), it creates two threads,
one that reads the serial or COM port that the XBee Smart Modem is connected to, and one that
reads the socket (clisock), that the MQTT client is connected to.
With:
The proxy script running
The MQTT client connected to the proxy script via localhost (127.0.0.1)
The XBee Smart Modem connected to the machine via USB and properly powered
AP, DL, and DE set correctly
the proxy acts as an intermediary between the MQTT client and the XBee Smart Modem, allowing the
MQTT client to use the data connection provided by the device.
Think of the proxy script as a translator between the MQTT client and the XBee Smart Modem. The
following figure shows the basic operation.
Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide
37
Getting started with the XBee Smart Modem Development Kit
Get started with MQTT
The thread that reads the serial port forwards any data received onward to the client socket, and the
thread reading the client socket forwards any data received onward to the serial port. This is
represented in the figure above.
The proxy script needs to be running before running an MQTT publish or subscribe script.
1. With the proxy script running, run the subscribe example from Example: receive messages
(subscribe) with MQTT, but change the connect line from client.connect("m2m.eclipse.org",
1883, 60) to client.connect("127.0.0.1", port=17300, keepalive=20). This connects the
MQTT client to the proxy script, which in turn connects to a broker via the XBee Smart
Modem’s internet connection.
2. Run the publish example from Example: send messages (publish) with MQTT in a third Python
instance (while the publish script is running you will have three Python scripts running at the
same time).
The publish script runs over your computer’s normal internet connection, and does not use the XBee
Smart Modem. You are able to see your published message appear in the subscribe script’s output
once it is received from the broker via the XBee Smart Modem. If you watch the output of the proxy
script during this process you can see the receptions and transmissions taking place.
The proxy script must be running before you run the subscribe and publish scripts. If you stop the
subscribe script, the socket closes, and the proxy script shows an error. If you try to start the proxy
script after starting the subscribe script, you may also see a socket error. To avoid these errors, it is
best to start the scripts in the correct order: proxy, then subscribe, then publish.
Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide
38
Getting started with the XBee Smart Modem Development Kit
Get started with CoAP
Get started with CoAP
Constrained Application Protocol (CoAP) is based on UDP connection and consumes low power to
deliver similar functionality to HTTP. This guide contains information about sending GET, POST, PUT
and DELETE operations by using the Coap Protocol with XCTU and Python code working with the XBee
Smart Modem and Coapthon library (Python 2.7 only).
The Internet Engineering Task Force describes CoAP as:
The protocol is designed for machine-to-machine (M2M) applications such as smart energy and
building automation. CoAP provides a request/response interaction model between application
endpoints, supports built-in discovery of services and resources, and includes key concepts of
the Web such as URIs and Internet media types. CoAP is designed to easily interface with HTTP
for integration with the Web while meeting specialized requirements such as multicast
support, very low overhead, and simplicity for constrained environments (source).
CoAP terms
When describing CoAP, we use the following terms:
Term
Meaning
Method
COAP's method action is similar to the HTTP method. This guide discusses the GET,
POST, PUT and DELETE methods. With these methods, the XBee Smart Modem can
transport data and requests.
URI
URI is a string of characters that identifies a resource served at the server.
Token
A token is an identifier of a message. The client uses the token to verify if the received
message is the correct response to its query.
Payload
The message payload is associated with the POST and PUT methods. It specifies the
data to be posted or put to the URI resource
Message ID The message ID is also an identifier of a message. The client matches the message ID
between the response and query.
CoAP quick start example
The following diagram shows the message format for the CoAP protocol; see ISSN: 2070-1721 for
details:
This is an example GET request:
44 01 C4 09 74 65 73 74 B7 65 78 61 6D 70 6C 65
Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide
39
Getting started with the XBee Smart Modem Development Kit
Get started with CoAP
The following table describes the fields in the GET request.
Field
HEX
Bits
Meaning
Ver
44
01
Version 01, which is mandatory here.
00
Type 0: confirmable.
TKL
0100
Token length: 4.
Code
01
000 00001
Code: 0.01, which indicates the GET method.
Message ID
C4 09
2 Bytes equal
to hex at left
Message ID. The response message will have the
same ID. This can help out identification.
Token
74 65 73 74 4 Bytes equal
to hex at left
Token. The response message will have the same
token. This can help out identification.
Option delta
B7
1011
Delta option: 11 indicates the option data is Uri-Path.
0111
Delta length: 7 indicates there are 7 bytes of data
following as a part of this delta option.
Option length
Option value
65 78 61 6D 7 Bytes equal
70 6C 65
to hex at left
Example.
Configure the device
1. Ensure that the device is set up correctly with the SIM card installed and the antennas
connected as described in Connect the hardware.
2. Open XCTU and click the Configuration working mode
button.
3. Add the XBee Smart Modem to XCTU; see Add a device.
4. Select a device from the Radio Modules list. XCTU displays the current firmware settings for
that device.
5. To switch to UDP communication, in the IP field, select 0 and click the Write button
6. To set the target IP address that the XBee Smart Modem will talk to, in the DL field type
52.43.121.77and click the Write button
. A CoAP server is publicly available at address
52.43.121.77.
7. To set the XBee Smart Modem to send data to port 5683 in decimal, in the DE field, type 1633
and click the Write button.
8. To move into Transparent mode, in the AP field, select 0 and click the Write button.
9. Wait for the AI (Association Indication) value to change to 0 (Connected to the Internet). You
can click Read
to get an update on the AI value.
Example: manually perform a CoAP request
Follow the steps in Configure the device prior to this example. This example performs the CoAP
GET request:
Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide
40
Getting started with the XBee Smart Modem Development Kit
Method: GET
URI: example
Given message token: test
1. Click the Consoles working mode button
Get started with CoAP
on the toolbar to add a customized packet.
2. From the AT console, click the Add new packet button
in the Send packets dialog. The
Add new packet dialog appears.
3. Click the HEX tab and type the name of the data packet: GET_EXAMPLE.
4. Copy and past the following text into the HEX input tab:
44 01 C4 09 74 65 73 74 B7 65 78 61 6D 70 6C 65
This is the CoAP protocol message decomposed by bytes to perform a GET request on an
example URI with a token test.
5. Click Add packet.
6. Click the Open button
7. Click Send selected packet. The message is sent to the public CoAP server configured in
Configure the device. A response appears in the Console log. Blue text is the query, red text is
the response.
The payload is Get to uri: example, which specifies that this is a successful CoAP GET to URI end
example, which was specified in the query.
Click the Close button to terminate the serial connection.
Example: use Python to generate a CoAP message
This example illustrates how the CoAP protocol can perform GET/POST/PUT/DELETE requests
similarly to the HTTP protocol and how to do this using the XBee Smart Modem. In this example, the
XBee Smart Modem talks to a CoAP Digi Server. You can use this client code to provide an abstract
wrapper to generate a CoAP message that commands the XBee Smart Modem to talk to the remote
CoAP server.
Note It is crucial to configure the XBee Smart Modem settings. See Configure the device and follow
the steps. You can target the IP address to a different CoAP public server.
1. Install Python 2.7. The Installation guide is located at: https://www.python.org/downloads/.
2. Download and install the Coapthon library in the python environment from
https://pypi.python.org/pypi/CoAPthon.
3. Download these two .txt files: Coap.txt and CoapParser.txt. After you download them, open the
files in a text editor and save them as .py files.
4. In the folder that you place the Coap.py and CoapParser.py files, press Shift + right-click and
then click Open command window.
5. At the command prompt, type python Coap.py and press Enter to run the program.
Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide
41
Getting started with the XBee Smart Modem Development Kit
Get started with CoAP
6. Type the USB port number that the XBee Smart Modem is connected to and press Enter. Only
the port number is required, so if the port is COM19, type 19.
Note If you do not know the port number, open XCTU and look at the XBee Smart Modem in the Radio
Modules list. This view provides the port number and baud rate, as in the figure below where the baud
rate is 9600 b/s.
7. Type the baud rate and press Enter. You must match the device's current baud rate.
XCTU provides the current baud rate in the BD Baud Rate field. In this example you would type
9600.
8. Press Y if you want an auto-generated example. Press Enter to build your own CoAP request.
9. If you press Y it generates a message with:
Method: POST
URI: example
payload: hello world
token: test
The send and receive message must match the same token and message id. Otherwise, the client reattempts the connection by sending out the request.
In the following figure, the payload contains the server response to the query. It shows the results for
when you press Enter rather than Y.
Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide
42
Getting started with the XBee Smart Modem Development Kit
Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide
Get started with CoAP
43
Getting started with the XBee Smart Modem
Development Kit
Configure the XBee Smart Modem using Digi Remote
Manager
Configure the XBee Smart Modem using Digi Remote Manager
Use Digi Remote Manager (https://remotemanager.digi.com/) to perform the operations in this
section. Each operation requires that you enable Remote Manager with the DO command and that
you connect the XBee Smart Modem to an access point that has an external Internet connection to
allow access to Digi Remote Manager.
Note Digi is consolidating our cloud services, Digi Device Cloud and Digi Remote Manager®, under the
Remote Manager name. This phased process does not affect device functionality or the functionality
of the web services and other features. However, customers will find that some user interface and
firmware functionality mention both Device Cloud and Digi Remote Manager.
Create a Remote Manager account
Digi Remote Manager is an on-demand service with no infrastructure requirements. Remote devices
and enterprise business applications connect to Remote Manager through standards-based web
services. This section describes how to configure and manage an XBee using Remote Manager. For
detailed information on using Remote Manager, refer to the Remote Manager User Guide, available
via the Documentation tab in Remote Manager.
Before you can manage an XBee with Remote Manager, you must create a Remote Manager account.
To create a Remote Manager account:
1. Go to https://www.digi.com/products/cloud/digi-remote-manager.
2. Click 30 DAY FREE TRIAL/LOGIN.
3. Follow the online instructions to complete account registration. You can upgrade your
Developer account to a paid account at any time.
When you are ready to deploy multiple XBee Smart Modems in the field, upgrade your account to
access additional Remote Manager features.
Get the XBee Smart Modem IMEI number
Before adding an XBee to your Remote Manager account inventory, you need to determine the
International Mobile Equipment Identity (IMEI) number for the device. Use XCTU to view the IMEI
number by querying the IM parameter.
Add a XBee Smart Modem to Remote Manager
To add an XBee to your Remote Manager account inventory, follow these steps:
Go to https://remotemanager.digi.com/.
1. Log in to your account
2. Click Device Management > Devices.
3. Click Add Devices. The Add Devices dialog appears.
4. Select IMEI #, and type or paste the IMEI number of the XBee you want to add. The IM
(IMEI) command provides this number.
Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide
44
Getting started with the XBee Smart Modem Development Kit
Software libraries
5. Click Add to add the device. The XBee is added to your inventory.
6. Click OK to close the Add Devices dialog and return to the Devices view.
Update the firmware
XBee Smart Modem supports Remote Manager firmware updates. To perform a firmware update, use
the following steps.
1. Download the updated firmware file for your device from Digi's support site. This is a zip file
containing .ebin and .mxi files for import.
2. Unzip the file.
3. In your Remote Manager account, click Device Management > Devices.
4. Select the first device you want to update.
5. To select multiple devices (must be of the same type), press the Control key and select
additional devices.
6. Click More in the Devices toolbar and select Update Firmware from the Update category of
the More menu. The Update Firmware dialog appears.
7. Click Browse to select the .ebin file that you unzipped earlier.
8. Click Update Firmware. The updated devices automatically reboot when the updates are
complete.
Software libraries
One way to communicate with the XBee device is by using a software library. The libraries available
for use with the XBee Smart Modem include:
n XBee Java library
XBee Python library
The XBee Java Library is a Java API. The package includes the XBee library, its source code and a
collection of samples that help you develop Java applications to communicate with your XBee devices.
The XBee Python Library is a Python API that dramatically reduces the time to market of XBee
projects developed in Python and facilitates the development of these types of applications, making it
an easy process.
Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide
45
Get started with MicroPython
This guide provides an overview of how to use MicroPython with the XBee Smart Modem. For in-depth
information and more complex code examples, refer to the Digi MicroPython Programming Guide.
Continue with this guide for simple examples to get started using MicroPython on the XBee Smart
Modem.
About MicroPython
MicroPython on the XBee Smart Modem
Use XCTU to enter the MicroPython environment
Use the MicroPython Terminal in XCTU
Example: hello world
Example: turn on an LED
Example: code a request help button
Exit MicroPython mode
Other terminal programs
Use picocom in Linux
Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide
47
47
47
48
48
48
49
54
54
55
46
Get started with MicroPython
About MicroPython
About MicroPython
MicroPython is an open-source programming language based on Python 3, with much of the same
syntax and functionality, but modified to fit on small devices with limited hardware resources, such as
microcontrollers, or in this case, a cellular modem.
Why use MicroPython
MicroPython enables on-board intelligence for simple sensor or actuator applications using digital and
analog I/O. MicroPython can help manage battery life. Cryptic readings can be transformed into useful
data, excess transmissions can be intelligently filtered out, modern sensors and actuators can be
employed directly, and logic can glue inputs and outputs together in an intelligent way.
For more information about MicroPython, see www.micropython.org.
For more information about Python, see www.python.org.
MicroPython on the XBee Smart Modem
The XBee Smart Modem has MicroPython running on the device itself. You can access a MicroPython
prompt from the XBee Smart Modem when you install it in an appropriate development board (XBDB
or XBIB), and connect it to a computer via a USB cable.
Note MicroPython does not work with SPI.
The examples in this guide assume:
n You have XCTU on your computer. See Configure the device using XCTU.
You have a terminal program installed on your computer. We recommend using the Use the
MicroPython Terminal in XCTU. This requires XCTU 6.3.7 or higher.
You have an XBee Smart Modem installed in an appropriate development board such as an
XBIB-U-DEV or an XBIB-2.
Note Most examples in this guide require the XBIB-U-DEV board.
The XBee Smart Modem is connected to the computer via a USB cable and XCTU recognizes it.
The board is powered by an appropriate power supply, 12 VDC and at least 1.1 A.
Use XCTU to enter the MicroPython environment
To use the XBee Smart Modem in the MicroPython environment:
1. Use XCTU to add the device(s); see Configure the device using XCTU and Add a device.
2. The XBee Smart Modem appears as a box in the Radio Modules information panel. Each
module displays identifying information about itself.
3. Click this box to select the device and load its current settings.
4. To set the device's baud rate to 115200 b/s, in the BD field select 115200 [7] and click the
Write button
. We recommend using flow control to avoid data loss, especially when pasting
large amounts of code/text.
Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide
47
Get started with MicroPython
Use the MicroPython Terminal in XCTU
5. To put the XBee Smart Modem into MicroPython mode, in the AP field select MicroPython
REPL [4] and click the Write button
6. Note what COM port(s) the XBee Smart Modem is using, because you will need this information
when you use terminal communication.
Use the MicroPython Terminal in XCTU
You can use the MicroPython Terminal to communicate with the XBee Smart Modem when it is in
MicroPython mode.1 This requires XCTU 6.3.7 or higher. To enter MicroPython mode, follow the steps
in Use XCTU to enter the MicroPython environment. To use the MicroPython Terminal:
1. Click the Tools drop-down menu
and select MicroPython Terminal. The terminal opens.
2. Click Open.
3. In the Select the Serial/USB port area, click the COM port that the device uses.
4. Verify that the baud rate and other settings are correct.
5. Click OK. The Open icon changes to Close
, indicating that the device is properly connected.
You can now type or paste MicroPython code in the terminal.
Example: hello world
1. At the MicroPython >>> prompt, type the Python command: print("Hello, World!")
2. Press Enter to execute the command. The terminal echos back Hello, World!.
Example: turn on an LED
1. Note the DS4 LED on the XBIB board. The following image highlights it in a red box. The LED is
normally off.
1See Other terminal programs if you do not use the MicroPython Terminal in XCTU.
Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide
48
Get started with MicroPython
Example: code a request help button
2. At the MicroPython >>> prompt, type the commands below, pressing Enter after each one.
After entering the last line of code, the LED illuminates. Anything after a # symbol is a
comment, and you do not need to type it.
Note You can easily copy and paste code from the online version of this Guide. Use caution with the
PDF version, as it may not maintain essential indentations.
import machine
from machine import Pin
led = Pin("D4", Pin.OUT, value=0) # Makes a pin object set to output 0.
# One might expect 0 to mean OFF and 1 to mean ON, and this is normally the
case.
# But the LED we are turning on and off is setup as what is# known as
"active low".
# This means setting the pin to 0 allows current to flow through the LED and
then through the pin, to ground.
3. To turn it off, type the following and press Enter:
led.value(1)
You have successfully controlled an LED on the board using basic I/O!
Example: code a request help button
This example provides a fast, deep dive into MicroPython designed to let you see some of the powerful
things it can do with minimal code. It is not meant as a tutorial; for in-depth examples refer to the Digi
Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide
49
Get started with MicroPython
Example: code a request help button
MicroPython Programming Guide.
Many stores have help buttons in their aisles that a customer can press to alert the store staff that
assistance is required in that aisle. You can implement this type of system using the Digi XBee Smart
Modem, and this example provides the building blocks for such a system. This example, based on SMS
paging, can have many other uses such as alerting someone with a text to their phone if a water
sensor in a building detects water on the floor, or if a temperature sensor reports a value that is too
hot or cold relative to normal operation.
Enter MicroPython paste mode
In the following examples it is helpful to know that MicroPython supports paste mode, where you can
copy a large block of code from this user guide and paste it instead of typing it character by character.
To use paste mode:
1. Copy the code you want to run. For example, copy the following code that is the code from the
LED example:
from machine import Pin
led = Pin("D4", Pin.OUT, value=0)
Note You can easily copy and paste code from the online version of this Guide. Use caution with the
PDF version, as it may not maintain essential indentations.
2. In the terminal, at the MicroPython >>> prompt type Ctrl-+E to enter paste mode. The terminal
displays paste mode; Ctrl-C to cancel, Ctrl-D to finish.
3. The code appears in the terminal occupying four lines, each line starts with its line number and
three = symbols. For example line 1 starts with 1===.
4. If the code is correct, press Ctrl+D to run the code and you should once again see the DS4 LED
turn on. If you get a Line 1 SyntaxError: invalid syntax error, see Syntax error at line 1.
(If you wish to exit paste mode without running the code, for example, or if the code did not
copy correctly, press Ctrl+C to cancel and return to the normal MicroPython >>> prompt).
5. Next turn the LED off. Copy the code below:
from machine import Pin
led = Pin("D4", Pin.OUT, value=1)
print("DS4 LED now OFF!")
print("Paste Mode Successful!")
6. Press Ctrl+E to enter paste mode.
7. Press Ctrl + Shift + V or right-click in the Terminal and select Paste to paste the copied code.
8. If the code is correct, press Ctrl+D to run it. The LED should turn off and you should see two
confirmation messages print to the screen.
Catch a button press
For this part of the example, you write code that responds to a button press on the XBIB-U-DEV board
that comes with the XBee Smart Modem Development Kit. The code monitors the pin connected to
the button on the board labeled SW2.
Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide
50
Get started with MicroPython
Example: code a request help button
On the board you see DIO0 written below SW2, to the left of the button. This represents the pin that
the button is connected to.
In MicroPython, you will create a pin object for the pin that is connected to the SW2 button. When you
create the pin object, the DIO0 pin is called D0 for short.
The loop continuously checks the value on that pin and once it goes to 0 (meaning the button has been
pressed) a print() call prints the message Button pressed! to the screen.
At the MicroPython >>> prompt, copy the following code and enter it into MicroPython using paste
mode and then run it:
# Import the Pin module from machine, for simpler syntax.
from machine import Pin
# Create a pin object for the pin that the button "SW2" is connected to.
dio0 = Pin("D0", Pin.IN, Pin.PULL_UP)
# Give feedback to inform user a button press is needed.
print("Waiting for SW2 press...")
# Create a WHILE loop that checks for a button press.
while (True):
if (dio0.value() == 0): # Once pressed.
print("Button pressed!") # Print message once pressed.
break # Exit the WHILE loop.
# When you press SW2, you should see "Button pressed!" printed to the
screen.
# You have successfully performed an action in response to a button press!
Note You can easily copy and paste code from the online version of this Guide. Use caution with the
PDF version, as it may not maintain essential indentations.
Note If you have problems pasting the code, see Syntax error at line 1. For SMS failures, see Error
Failed to send SMS.
Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide
51
Get started with MicroPython
Example: code a request help button
Send a text (SMS) when the button is pressed
After creating a while loop that checks for a button press, add sending an SMS to your code. Instead of
printing Button pressed! to the screen, this code sends Button pressed to a cell phone as a text
(SMS) message.
To accomplish this, use the sms_send() method, which sends a string to a given phone number. It
takes the arguments in the order of
1. 
2. 
Before you run this part of the example, you must create a variable that holds the phone number of
the cell phone or mobile device you want to receive the SMS.
1. To do this, at the MicroPython >>> prompt, type the following command, replacing 1123456789
with the full phone number (no dashes, spaces, or other symbols) and press Enter:
ph = 1123456789
2. After you create this ph variable with your phone number, copy the code below and enter it
into MicroPython using paste mode and then run it.
from machine import Pin
import network # Import network module
import time
c = network.Cellular() # initialize cellular network parameter
dio0 = Pin("D0", Pin.IN, Pin.PULL_UP)
while not c.isconnected(): # While no network connection.
print("Waiting for connection to cell network...")
time.sleep(5)
print("Connected.")
# Give feedback to inform user a button press is needed.
print("Waiting for SW2 press...")
while (True):
if (dio0.value() == 0):
# When SW2 is pressed, the module will send an SMS
# message saying "Button pressed" to the given target cell phone
number.
try:
c.sms_send(ph, 'Button Pressed')
print("Sent SMS successfully.")
except OSError:
print("ERROR- failed to send SMS.")
# Exit the WHILE loop.
break
Note You can easily copy and paste code from the online version of this Guide. Use caution with the
PDF version, as it may not maintain essential indentations.
Note If you have problems pasting the code, see Syntax error at line 1. For SMS failures, see Error
Failed to send SMS.
Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide
52
Get started with MicroPython
Example: code a request help button
Add the time the button was pressed
After you add the ability to send an SMS to the code, add functionality to insert the time at which the
button was pressed into the SMS that is sent. To accomplish this:
1. Create a UDP socket with the socket() method.
2. Save the IP address and port of the time server in the addr variable.
3. Connect to the time server with the connect() method.
4. Send hello to the server to prompt it to respond with the current date and time.
5. Receive and store the date/time response in the buf variable.
6. Send an SMS in the same manner as before using the sms_send() method, except that you add
the time into the SMS message, such that the message reads: [Button pressed at: YYYY-MMDD HH:MM:SS]
To verify that your phone number is still in the memory, at the MicroPython >>> prompt, type ph and
press Enter.
If MicroPython responds with your number, copy the following code and enter it into MicroPython
using paste mode and then run it. If it returns an error, enter your number again as shown in Send a
text (SMS) when the button is pressed. With your phone number in memory in the ph variable, copy
the code below and enter it into MicroPython using paste mode and then run it.
from machine import Pin
import network
import usocket
import time
c = network.Cellular()
dio0 = Pin("D0", Pin.IN, Pin.PULL_UP)
while not c.isconnected(): # While no network connection.
print("Waiting for connection to cell network...")
time.sleep(5)
print("Connected.")
# Give feedback to inform user a button press is needed.
print("Waiting for SW2 press...")
while (1):
if (dio0.value() == 0):
# When button pressed, now the module will send "Button Press" AND
# the time at which it was pressed in an SMS message to the given
# target cell phone number.
socketObject = usocket.socket(usocket.AF_INET, usocket.SOCK_DGRAM)
# Connect the socket object to the web server specified in
"address".
addr = ("52.43.121.77", 10002)
socketObject.connect(addr)
bytessent = socketObject.send("hello")
print("Sent %d bytes on socket" % bytessent)
buf = socketObject.recv(1024)
# Send message to the given number. Handle error if it occurs.
try:
c.sms_send(ph, 'Button Pressed at: ' + str(buf))
print("Sent SMS successfully.")
except OSError:
print("ERROR- failed to send SMS.")
Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide
53
Get started with MicroPython
Exit MicroPython mode
# Exit the WHILE loop.
break
Note You can easily copy and paste code from the online version of this Guide. Use caution with the
PDF version, as it may not maintain essential indentations.
Now you have a system based on the XBee Smart Modem that sends an SMS in response to a certain
input, in this case a simple button press.
Note If you have problems pasting the code, see Syntax error at line 1. For SMS failures, see Error
Failed to send SMS.
Exit MicroPython mode
To exit MicroPython mode:
1. In the XCTU MicroPython Terminal, click the green Close button
2. Click Close at the bottom of the terminal to exit the terminal.
3. In XCTU's Configuration working mode
the Write button
, change AP API Enable to another mode and click
. We recommend changing to Transparent mode [0], as most of the
examples use this mode.
Other terminal programs
If you do not use the MicroPython Terminal in XCTU, you can use other terminal programs to
communicate with the XBee Smart Modem. If you use Microsoft Windows, follow the instructions for
Tera Term, if you use Linux, follow the instructions for picocom. To download these programs:
n Tera Term for Windows; see https://ttssh2.osdn.jp/index.html.en.
Picocom for Linux; see https://developer.ridgerun.com/wiki/index.php/Setting_up_Picocom_-_
Ubuntu and for the source code and in-depth information https://github.com/npatefault/picocom.
Tera Term for Windows
With the XBee Smart Modem in MicroPython mode (AP = 4), you can access the MicroPython prompt
using a terminal.
1. Open Tera Term. The Tera Term: New connection window appears.
2. Click the Serial radio button to select a serial connection.
3. From the Port: drop-down menu, select the COM port that the XBee Smart Modem is
connected to.
4. Click OK. The COMxx - Tera Term VT terminal window appears and Tera Term attempts to
connect to the device at a baud rate of 9600 b/s. The terminal will not allow communication
with the device since the baud rate setting is incorrect. You must change this rate as it was
Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide
54
Get started with MicroPython
Use picocom in Linux
previously set to 115200 b/s.
5. Click Setup and Serial Port. The Tera Term: Serial port setup window appears.
6. In the Tera Term: Serial port setup window, set the parameters to the following values:
Port: Shows the port that the XBee Smart Modem is connected on.
Baud rate: 115200
Data: 8 bit
Parity: none
Stop: 1 bit
Flow control: hardware
Transmit delay: N/A
7. Click OK to apply the changes to the serial port settings. The settings should go into effect
right away.
8. To verify that local echo is not enabled and that extra line-feeds are not enabled:
a. In Tera Term, click Setup and select Terminal.
b. In the New-line area of the Tera Term: Serial port setup window, click the
Receive drop-down menu and select CR if it does not already show that value.
c. Make sure the Local echo box is not checked.
9. Click OK.
10. Press Ctrl+B to get the MicroPython version banner and prompt.
Now you can type MicroPython commands at the >>> prompt.
Use picocom in Linux
With the XBee Smart Modem in MicroPython mode (AP = 4), you can access the MicroPython prompt
using a terminal.
Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide
55
Get started with MicroPython
Use picocom in Linux
Note The user must have read and write permission for the serial port the XBee Smart Modem is
connected to in order to communicate with the device.
1. Open a terminal in Linux and type picocom -b 115200 /dev/ttyUSB0. This assumes you have
no other USB-to-serial devices attached to the system.
2. Press Ctrl+B to get the MicroPython version banner and prompt. You can also press Enter to
bring up the prompt.
If you do have other USB-to-serial devices attached:
1. Before attaching the XBee Smart Modem, check the directory /dev/ for any devices named
ttyUSBx, where x is a number. An easy way to list these is to type: ls /dev/ttyUSB*. This
produces a list of any device with a name that starts with ttyUSB.
2. Take note of the devices present with that name, and then connect the XBee Smart Modem.
3. Check the directory again and you should see one additional device, which is the XBee Smart
Modem.
4. In this case, replace /dev/ttyUSB0 at the top with /dev/ttyUSB, where 
is the new number that appeared.
5. It should connect and show Terminal ready.
Now you can type MicroPython commands at the >>> prompt.
Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide
56
Technical specifications
Interface and hardware specifications
RF characteristics
Networking specifications
Power requirements
Power consumption
Electrical specifications
Regulatory approvals
Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide
58
58
58
58
59
59
60
57
Technical specifications
Interface and hardware specifications
Interface and hardware specifications
The following table provides the interface and hardware specifications for the device.
Specification
Value
Dimensions
2.438 x 3.294 cm (0.960 x 1.297 in)
Weight
5 g (0.18 oz)
Operating temperature
-40 to +80 °C
Antenna connector
U.FL for primary and secondary antennas
Digital I/O
13 I/O lines
ADC
4 10-bit analog inputs
RF characteristics
The following table provides the RF characteristics for the device.
Specification
Cellular value
BLE value
Modulation
LTE/4G – QPSK, 16 QAM
QPSK
Transmit power
23 dBm
9 dBm
Receive sensitivity
-102 dBm
-92 dBm
Over-the-air maximum data rate
10 Mb/s
2 Mb/s
Networking specifications
The following table provides the networking and carrier specifications for the device.
Specification
Value
Addressing options
TCP/IP and SMS
Carrier and technology
AT&T LTE Cat 1
Supported bands
2, 4 and 12
Security
SSL/TLS
Power requirements
The following table provides the power requirements for the device.
Specification
Value
Supply voltage range
3.0 to 5.5 VDC
Extended voltage range
2.7 to 5.5 VDC
Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide
58
Technical specifications
Power consumption
Power consumption
Specification
State
Average
current
Measured peak
current
2.4 GHz TX
Active transmit @ 3.3 V
70 mA
2.4 GHz RX
Active receive @ 3.3 V
30 mA
Cellular Tx+RX current
Active transmit, 23 dBm @ 3.3 V
860 mA
1020 mA
Cellular Tx+RX current
Active transmit, 23 dBm @ 5.0 V
555 mA
630 mA
Cellular TX Only
current
Active transmit, 23 dBm @ 3.3 V
680 mA
N/A
Cellular Rx + ACK
current
Active receive @ 3.3 V
530 mA
N/A
Cellular Rx + ACK
current
Active receive @ 5 V
360 mA
N/A
Cellular RX Only
current
Active receive @ 3.3 V
300 mA
N/A
Idle current
Idle/connected, listening @ 3.3
110 mA
N/A
Idle current
Idle/connected, listening @ 5 V
75 mA
N/A
Sleep current
Not connected, Deep
Sleep @ 3.3 V
12 µA
N/A
Electrical specifications
The following table provides the electrical specifications for the XBee Smart Modem.
Symbol
Parameter
Condition
VCCMAX Maximum limits
of VCC line
VDD_IO
Internal supply
voltage for I/O
While in deep sleep and
during initial power up
VDD_IO
Internal supply
voltage for I/O
In normal running mode
Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide
Min
Typical Max
Units
5.5
Min
(VCC0.3, 3.3)
3.3
3.3 V
59
Technical specifications
Regulatory approvals
Symbol
Parameter
Condition
Min
VI
Voltage on 5 V
tolerant pins
XBee pin 6
0.3
Min
(5.25,VDD_
IO+2)1
0.3
VDD_IO +
0.3
Other input pins
Typical Max
Units
VIL
Input low voltage
0.3*VDD_IO V
VIH
Input high
voltage
VOL
Voltage output
low
Sinking 3 mA VDD_IO = 3.3 V
VOH
Voltage output
high
Sourcing 3 mA VDD_IO = 3.3
I_IN
Input leakage
current
High Z state I/O connected
to Ground or VDD_IO
0.1
RPU
Internal pull-up
resistor
Enabled
40
kΩ
RPD
Internal pulldown resistor
Enabled
40
kΩ
0.7*VDD_
IO
0.2*VDD_IO V
0.8*VDD_
IO
100
nA
Regulatory approvals
The following table provides the regulatory and carrier approvals for the device.
Specification
Value
Model
XB3C1
United States
FCC ID: MCQ-XB3C1
Contains FCC ID:RI7XE866A1NA
Contains IC: 1846A-XB3C1
IC: 1846A-XB3C1
Contains IC: 5131A-XE866A1NA
Europe (CE)
N/A
RoHS
Lead-free and RoHS compliant
Australia
N/A
Verizon end-device certified
No
AT&T end-device certified
Yes
PTCRB end-device certified
Yes
1Pin 6 is also 5 V tolerant even when the XBee Smart Modem is not powered. We recommend only driving this
pin with 3.3 V for compatibility with other XBee products. The VBUS line is not used to enable/disable USB on
this product.
Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide
60
Hardware
Mechanical drawings
Pin signals
RSSI PWM
SIM card
The Associate LED
Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide
62
62
64
64
64
61
Hardware
Mechanical drawings
Mechanical drawings
The following figures show the mechanical drawings for the XBee Smart Modem. All dimensions are in
inches.
Pin signals
The pin locations are:
Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide
62
Hardware
Pin signals
The following table shows the pin assignments for the through-hole device. In the table, low-asserted
signals have a horizontal line above signal name.
Pin Name
Direction Default
Description
Pin Name
Direction
Description
Default
VCC
DOUT
Output
Output
UART Data Out
DIN / CONFIG
Input
Input
UART Data In
DIO12 / SPI_MISO
Either
Disabled Digital I/O 12 or SPI Slave Output line
RESET
Input
PWM0 / RSSI /
DIO10/USB_VBUS
Either
Output
DIO11/USB D+
Either
Disabled Digital I/O 11 or USB D+ line
USB D-
DTR / SLEEP_RQ/
DIO8
10
GND
11
DIO4 / SPI_MOSI
Either
Disabled Digital I/O 4 or SPI Slave Input Line
12
CTS / DIO7
Either
Output
Output Clear-to-Send Flow Control or Digital I/O 7
13
ON /SLEEP/DIO9
Output
Output
Module Status Indicator or Digital I/O 9
14
VREF
15
Associate / DIO5
Either
Output
16
RTS / DIO6
Either
Disabled Input Request-to-Send Flow Control, Digital I/O 6
17
AD3 / DIO3 / SPI_
SS
Either
Disabled Analog Input 3 or Digital I/O 3, SPI low enabled
select line
18
AD2 / DIO2 / SPI_
CLK
Either
Disabled Analog Input 2 or Digital I/O 2, SPI Clock line
19
AD1 / DIO1 / SPI_
ATTN
Either
Disabled Analog Input 1 or Digital I/O 1, SPI Attention line
output
20
AD0 / DIO0
Either
Input
Power supply
PWM Output 0 / RX Signal Strength Indicator /
Digital I/O 10
Direct USB D- line
Either
Disabled Pin Sleep Control Line or Digital I/O 8
Ground
Feature not supported on this device. Used on
other XBee devices for analog voltage reference.
Associated Indicator, Digital I/O 5
Analog Input 0, Digital I/O 0
Pin connection recommendations
The recommended minimum pin connections are VCC, GND, DIN, DOUT, RTS, DTR and RESET.
Firmware updates require access to these pins.
To ensure compatibility with future updates, make USB D+ and D- (pin 7 and pin 8) available in your
design.
Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide
63
Hardware
RSSI PWM
RSSI PWM
The XBee Smart Modem features an RSSI/PWM pin (pin 6) that, if enabled, adjusts the PWM output to
indicate the signal strength of the cellular connection. Use P0 (DIO10/PWM0 Configuration) to enable
the RSSI pulse width modulation (PWM) output on the pin. If P0 is set to 1, the RSSI/PWM pin outputs a
PWM signal where the frequency is adjusted based on the received signal strength of the cellular
connection.
The RSSI/PWM output is enabled continuously unlike other XBee products where the output is enabled
for a short period of time after each received transmission. If running on the XBIB development board,
DIO10 is connected to the RSSI LEDs, which may be interpreted as follows:
Number of LEDs turned
PWM duty cycle on
Received signal strength (dBm)
79.39% or more
-83 dBm or higher
62.42% to
79.39%
-93 to -83 dBm
45.45% to
62.42%
-103 to -93 dBm
Less than
45.45%
Less than -103 dBm, or no cellular network
connection
SIM card
The XBee Smart Modem uses a 4FF (Nano) size SIM card.
CAUTION! Never insert or remove SIM card while the power is on!
The Associate LED
The following table describes the Associate LED functionality. For the location of the Associate LED on
the XBIB-U development board, see number 6 on the XBIB-U-DEV reference.
LED status
Blink
timing
On, solid
Double blink
Meaning
Not joined to a mobile network.
½ second The last TCP/UDP/SMS attempt failed. If the LED has this pattern,
you may need to check DI (Device Cloud Indicator) or CI
(Protocol/Connection Indication) for the cause of the error.
Standard single blink 1 second
Normal operation.
The normal association LED signal alternates evenly between high and low as shown below:
Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide
64
Hardware
The Associate LED
Where the low signal means LED off and the high signal means LED on.
When CI is not 0 or 0xFF, the Associate LED has a different blink pattern that looks like this:
Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide
65
Antenna recommendations
Antenna connections
Antenna placement
Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide
67
68
66
Antenna recommendations
Antenna connections
Antenna connections
CAUTION! The XBee Smart Modem will not function properly with only the secondary
antenna port connected!
The XBee Smart Modem has two U.FL antenna ports; a primary on the upper left of the board and a
secondary port on the upper right, see the drawing below. You must connect the primary port and the
secondary port is optional. The secondary antenna improves receive performance in certain
situations, so we recommend it for best results.
See FCC-approved antennas for a list of approved antennas.
Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide
67
Antenna recommendations
Antenna placement
Connect the antenna cables as shown below.
WARNING! Cable directions matter. Do not cover the integrated antenna areas (the red
squares below) with cables. The left cable can travel up or down only.
Antenna placement
For optimal cellular reception, keep the antenna as far away from metal objects and other electronics
(including the XBee Smart Modem) as possible. Often, small antennas are desirable, but come at the
cost of reduced range and efficiency.
Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide
68
Design recommendations
Cellular component firmware upgrades
USB Direct design
Power supply considerations
Add a capacitor to the RESET line
Heat considerations and testing
Heat sink guidelines
Add a fan to provide active cooling
Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide
70
70
70
70
71
71
73
69
Design recommendations
Cellular component firmware upgrades
Cellular component firmware upgrades
Even if you do not plan to use the USB interface, we strongly recommend you provide a way to access
the USB to support direct firmware upgrades of the cellular modem.
One way to provide access to the USB interface is to connect XBee pins 6, 7, and 8, and 10 to an
unpopulated USB connector; see USB Direct design for more information. At a minimum you should
connect pins 7 and 8 to test points so they are easy to wire to a connector if necessary.
If you are using pins 6, 7, and 8 for other purposes you must provide a way to disconnect those
interfaces during USB operation, such as using zero ohm resistors.
USB Direct design
Connect USB data pins 7 and 8 (USB_D+ and USB_D- respectively) on the XBee Smart Modem to the
appropriate pins on the host processor or connector. You may optionally connect pin 6 to VBUS if you
want USB to be enabled based on whether your host is connected. Alternatively, you may configure
VBUS in software; see USB direct mode for more details. VBUS is only used as a reference, not for
powering anything on the XBee Smart Modem, so it may be routed as a standard signal trace.
The USB interface follows the USB 2.0 high speed specification and data lines must be designed as a
90 Ω differential pair. Both traces should be the same length and the overall trace length should be
kept as short as possible. If you are connecting to a USB connector then we recommend that you
employ an ESD suppressor appropriate for USB 2.0 HS (for example the Littelfuse PESD0402-140).
Other than the ESD suppressor, do not place additional components in the signal paths. The
suppressor is not needed if you are connecting to an on-board host processor.
Power supply considerations
When considering a power supply, use the following design practices.
1. Power supply ripple should be less than 75 mV peak to peak.
2. The power supply should be capable of providing a minimum of 1.5 A at 3.3 V (5 W). Keep in
mind that operating at a lower voltage requires higher current capability from the power
supply to achieve the 5 W requirement.
3. Place sufficient bulk capacitance on the XBee VCC pin to maintain voltage above the minimum
specification during inrush current. Inrush current is about 2 A during initial power up of cellular
communications and wakeup from sleep mode.
4. Place smaller high frequency ceramic capacitors very close to the XBee Smart Modem VCC pin
to decrease high frequency noise.
5. Use a wide power supply trace or power plane to ensure it can handle the peak current
requirements with minimal voltage drop. We recommend that the power supply and trace be
designed such that the voltage at the XBee VCC pin does not vary by more than 0.1 V between
light load (~0.5 W) and heavy load (~3 W).
Add a capacitor to the RESET line
In high EMI noise environments, we recommend adding a 10 nF ceramic capacitor very close to pin 5.
Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide
70
Design recommendations
Heat considerations and testing
Heat considerations and testing
The XBee Smart Modem may generate significant heat during sustained operation. In addition to
heavy data transfer, other factors that can contribute to heating include ambient temperature, air
flow around the device, and proximity to the nearest cellular tower (the XBee Smart Modem must
transmit at a higher power level when communicating over long distances). Overheating can cause
device malfunction and potential damage. In order to avoid this it is important to consider the
application the XBee Smart Modem is going into and mitigate heat issues if necessary. We recommend
that you perform thermal testing in your application to determine the resulting steady state
temperature of the XBee Smart Modem. Use TP (Temperature) to estimate the device temperature.
Convert the TP reading from hex format to decimal.
You also need to know the ambient temperature and the average current consumption during your
test. If you do not have a way to measure current consumption you can estimate it from the table in
the next section.
Use those results to approximate the maximum safe ambient temperature for the XBee Smart
Modem, TMAX,amb, with the following equation:
Where:
TXBee is the steady state temperature of the XBee Smart Modem that you measured during your test
(if using the TP command, be sure to convert from hex format to decimal).
Tamb,test is the ambient air temperature during your test.
IAVG,test is the average current measured during your test.
IMAX is the average current draw expected for your application when transmitting at maximum RF
power; see Power consumption.
Heat sink guidelines
Based on the results of your thermal testing you may find it is advisable or required to implement a
method of dissipating excess heat. This section explains how to employ a heat sink on top of the XBee
Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide
71
Design recommendations
Heat sink guidelines
Smart Modem.
A bolt-down style heat sink on top of the XBee Smart Modem provides the best performance. An
example part number is Advanced Thermal Solutions ATS-PCBT1084/ATS-PCB1084. You must use an
electrically non-conductive thermal gasket on top of the XBee device under the area that will be
covered by the heat sink. A thermal gasket such as Gap Pad® 2500S20 is suitable for this purpose. We
recommend using a gasket with thickness of at least 0.080 in to ensure that components on top of
the XBee device do not tear through the material when pressure is applied to the heat sink.
Install the SIM card prior to placement of the heat sink. Position the thermal gasket and heat sink
assembly on the top of the device so that it covers the entire section shown inside the blue box below
(covering the RF shield with thermal gasket is optional because the RF shield is allowed to directly
contact the heat sink). Do not cover the U.FL connectors.
When attaching to the host PCB, tighten the mounting hardware until the gasket is compressed at
least 25% and the heat sink is snug against the RF shield. Avoid overtightening. To prevent shorting,
check that the surface of the heat sink does not directly contact any of the XBee device components.
The following table provides a list of typical scenarios and the maximum ambient temperature at
which the XBee Smart Modem can be safely operated under that condition. These are provided only as
guidelines as your results will vary based on application. We recommend that you perform sufficient
testing, as explained in Heat considerations and testing, to ensure that the XBee Smart Modem does
not exceed temperature specifications.
Maximum safe
ambient temperature
Heat
sink
Peak data No
(boltconsumed heat down
(MB/hr)
sink style)
Average
current
consumption
(VCC = 3.3V)
Example application
Maximum
transmission
duty cycle
950 mA
Running video camera
500 to
2000
N/A
49 C
70 C
50% duty cycle
475 mA
Running low resolution
video camera
200 to 400 TBD
65 C
75 C
Scenario
Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide
Heat
sink
and
fan
72
Design recommendations
Add a fan to provide active cooling
Maximum safe
ambient temperature
Scenario
Average
current
consumption
(VCC = 3.3V)
Example application
Heat
sink
Peak data No
(boltconsumed heat down
(MB/hr)
sink style)
Heat
sink
and
fan
20% duty cycle
200 mA
Sending high resolution
photo less than once
per minute
50 to 150
TBD
74 C
78 C
Device awake,
limited
transmissions
170 mA
Updating traffic sign
1 to 10
TBD
75 C
80 C
Device primarily
asleep, very
limited
transmissions
20 mA
Small data
Less than
transmission/receptions 0.1
which occur once per
hour
80 C
80 C
80 C
Add a fan to provide active cooling
Another option for heat mitigation is to add a fan to your system to provide active cooling. You can use
a fan instead of or in addition to a heat sink. The XBee Smart Modem offers a fan control feature on
I/O pin DIO11 (pin 7). When the functionality is enabled, that line is pulled high to indicate when the fan
should be turned on. The line is pulled high when the device gets above 70 °C and the cellular
component is running, and turns off when the device drops below 65 °C.
To enable the functionality set P1 (DIO11/PWM1 Configuration) to 1. Note that the I/O pin is not
capable of driving a fan directly; you must implement a circuit to power the fan from a suitable power
source.
Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide
73
Cellular connection process
Connecting
Cellular network
Data network connection
Data communication with remote servers (TCP/UDP)
Disconnecting
SMS encoding
Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide
75
75
75
75
75
76
74
Cellular connection process
Connecting
Connecting
In normal operations, the XBee Smart Modem automatically attempts both a cellular network
connection and a data network connection on power-up. The sequence of these connections is as
follows:
Cellular network
1. The device powers on.
2. It looks for cellular towers.
3. It chooses a candidate tower with the strongest signal.
4. It negotiates a connection.
5. It completes cellular registration; the phone number and SMS are available.
Data network connection
1. The network enables the evolved packet system (EPS) bearer with an access point name
(APN). See AN (Access Point Name) if you have APN issues. You can use OA (Operating APN) to
query the APN value currently configured in the cellular component.
2. The device negotiates a data connection with the access point.
3. The device receives its IP configuration and address.
4. The AI (Association Indication) command now returns a 0 and the sockets become available.
Data communication with remote servers (TCP/UDP)
Once the data network connection is established, communication with remote servers can be
initiated in several ways:
n Transparent mode data sent to the serial port (see TD (Text Delimiter) and RO (Packetization
Timeout) for timing).
API mode: Transmit (TX) Request: IPv4 - 0x20 received over the serial connection.
Digi Remote Manager connectivity begins.
Data communication begins when:
1. A socket opens to the remote server.
2. Data is sent.
Data connectivity ends when:
1. The server closes the connection.
2. The TM timeout expires (see TM (IP Client Connection Timeout)).
3. The cellular network may also close the connection after a timeout set by the network
operator.
Disconnecting
When the XBee Smart Modem is put into Airplane mode or deep sleep is requested:
Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide
75
Cellular connection process
SMS encoding
1. Sockets are closed, cleanly if possible.
2. The cellular connection is shut down.
3. The cellular component is powered off.
Note We recommend entering Airplane mode before resetting or rebooting the device to allow the
cellular module to detach from the network.
SMS encoding
The XBee Smart Modem transmits SMS messages using the standard GSM 03.38 character set.1
Because this character set only provides 7 bits of space per character, the XBee Smart Modem
ignores the most significant bit of each octet in an SMS transmission payload.
The device converts incoming SMS messages to ASCII. Characters that cannot be represented in
ASCII are replaced with a space (' ', or 0x20 in hex). This includes emoji and other special characters.
1Also referred to as the GSM 7-bit alphabet.
Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide
76
Modes
Select an operating mode
Transparent operating mode
API operating mode
Bypass operating mode
USB direct mode
Command mode
Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide
78
79
79
79
80
80
77
Modes
Select an operating mode
Select an operating mode
The XBee Smart Modem interfaces to a host device such as a microcontroller or computer through a
logic-level asynchronous serial port. It uses a UART for serial communication with those devices.
The XBee Smart Modem supports three operating modes: Transparent operating mode, API operating
mode, and Bypass operating mode. The default mode is Transparent operating mode. Use the AP (API
Enable) command to select a different operating mode.
The following flowchart illustrates how the modes relate to each other.
Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide
78
Modes
Transparent operating mode
Transparent operating mode
Devices operate in this mode by default. The device acts as a serial line replacement when it is in
Transparent operating mode. The device queues all serial data it receives through the DIN pin for RF
transmission. When a device receives RF data, it sends the data out through the DOUT pin. You can set
the configuration parameters using Command mode.
The IP (IP Protocol) command setting controls how Transparent operating mode works for the XBee
Smart Modem.
Note Transparent operation is not available when using SPI.
API operating mode
API operating mode is an alternative to Transparent operating mode. API mode is a frame-based
protocol that allows you to direct data on a packet basis. The device communicates UART or SPI data
in packets, also known as API frames. This mode allows for structured communications with
computers and microcontrollers.
The advantages of API operating mode include:
n It is easier to send information to multiple destinations
The host receives the source address for each received data frame
You can change parameters without entering Command mode
Bypass operating mode
CAUTION! Bypass operating mode is an alternative to Transparent and API modes for
advanced users with special configuration needs. Changes made in this mode might
change or disable the device and we do not recommended it for most users.
In Bypass mode, the device acts as a serial line replacement to the cellular component. In this mode,
the XBee Smart Modem exposes all control of the cellular component's AT port through the UART. If
you use this mode, you must setup the cellular modem directly to establish connectivity. The modem
does not automatically connect to the network.
Note The cellular component can become unresponsive in Bypass mode. See Unresponsive cellular
component in Bypass mode for help in this situation.
When Bypass mode is active, most of the XBee Smart Modem's AT commands do not work. For
example, IM (IMEI) may never return a value, and DB does not update. In this configuration, the
firmware does not test communication with the cellular component (which it does by sending AT
commands). This is useful in case you have reconfigured the cellular component in a way that makes it
incompatible with the firmware. Bypass operating mode exists for users who wish to communicate
directly with the cellular component settings and do not intend to use XBee Smart Modem software
features such as API mode.
Command mode is available while in Bypass mode; see Enter Command mode for instructions.
Enter Bypass operating mode
To configure a device for Bypass operating mode:
Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide
79
Modes
USB direct mode
1. Set the AP (API Enable) parameter value to 5.
2. Send WR command to write the changes.
3. Send FR (Force Reset) to reboot the device.
4. After rebooting, enter Command mode and verify that Bypass operating mode is active by
querying AI (Association Indication) and confirming that it returns a value of 0x2F.
It may take a moment for Bypass operating mode to become active.
Leave Bypass operating mode
To configure a device to leave Bypass operating mode:
1. Set AP (API Enable) to something other than 5.
2. Send WR command to write the changes.
3. Send FR (Force Reset) to reboot the device.
4. After rebooting, enter Command mode and verify that Bypass operating mode is not active by
querying AI (Association Indication) and confirming that it returns a value other than 0x2F.
Restore cellular settings to default in Bypass operating mode
Send AT&F1 to reset the cellular component to its factory profile.
USB direct mode
This mode allows you to replace the cellular component with the XBee Smart Modem such that the
USB lines are the same through a configuration option.
Enable USB direct mode
Set P1 (DIO11/PWM1 Configuration) to 7 to enable USB direct mode. When set to 7 DIO11/PWM1 (pin
7) brings out the USB D+ signal of the cellular component. The USB D- signal is available on pin 8. With
these pins connected to a USB host a direct connection is made to the cellular component which is not
mediated by the XBee processor.
When in USB direct mode AI (Association Indication) returns 0x2B.
Command mode
Command mode is a state in which the firmware interprets incoming characters as commands. It
allows you to modify the device’s configuration using parameters you can set using AT commands.
When you want to read or set any parameter of the device when operating in Transparent mode, you
have to enter Command mode and send an AT command. Every AT command starts with the letters
AT followed by the two characters that identify the command and then by some optional configuration
values.
The three operating modes are controlled by the AP (API Enable) setting, but Command mode is
always available as a mode the XBee Smart Modem can enter while configured for any of the
operating modes.
Command mode is available on the UART interface in both Transparent and API modes. You cannot
use the SPI interface to enter Command mode.
Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide
80
Modes
Command mode
Enter Command mode
To get a device to switch into this mode, you must issue the following sequence: +++ within one
second. There must be at least one second preceding and following the +++ sequence. Both the
command character (CC) and the silence before and after the sequence (GT) are configurable. When
the device sees a full second of silence in the data stream (the guard time, GT) followed by the string
+++ (without Enter or Return) and another full second of silence, it knows to stop sending data and
start accepting commands locally.
Note Do not press Return or Enter after typing +++ because it will interrupt the guard time silence
and prevent you from entering Command mode.
When the device is in Command mode, it listens for user input and is able to receive AT commands on
the UART. If CT time (default is 10 seconds) passes without any user input, the device drops out of
Command mode and returns to the previous operating mode (Transparent, Bypass, API, Python, and
so forth).
You can customize the command character, the guard times and the timeout in the device’s
configuration settings. For more information, see CC (Command Sequence Character), CT (Command
Mode Timeout) and GT (Guard Times).
Troubleshooting
Failure to enter Command mode is often due to baud rate mismatch. Ensure that the baud rate of the
connection matches the baud rate of the device. By default, the BD parameter = 3 (9600 b/s).
There are two alternative ways to enter Command mode:
n A serial break for six seconds enters Command mode. The "break" command can be issued
from a serial console, and is often a button or menu item.
Asserting DIN (serial break) upon power up or reset enters Command mode. XCTU guides you
through a reset and automatically issues the break when needed.
Both of these methods temporarily set the device's baud rate to 9600 and return an OK on the UART
to indicate that Command mode is active. When Command mode exits, the device returns to normal
operation at the baud rate the BD parameter is set to.
Send AT commands
Once the device enters Command mode, use the syntax in the following figure to send AT commands.
Every AT command starts with the letters AT, which stands for "attention." The AT is followed by two
characters that indicate which command is being issued, then by some optional configuration values.
To read a parameter value stored in the device’s register, omit the parameter field.
The preceding example changes the IP protocol to SMS.
Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide
81
Modes
Command mode
Multiple AT commands
You can send multiple AT commands at a time when they are separated by a comma in Command
mode; for example, ATSH,SL.
Parameter format
Refer to the list of AT commands for the format of individual AT command parameters. Valid formats
for hexidecimal values include with or without a leading 0x for example FFFF or 0xFFFF.
Response to AT commands
When reading parameters, the device returns the current parameter value instead of an OK message.
Apply command changes
Any changes you make to the configuration command registers using AT commands do not take effect
until you apply the changes. For example, if you send the BD command to change the baud rate, the
actual baud rate does not change until you apply the changes. To apply changes:
1. Send the AC (Apply Changes) command.
or:
2. Exit Command mode.
Make command changes permanent
Issue a WR command command to save the changes. WR writes parameter values to non-volatile
memory so that parameter modifications persist through subsequent resets.
Exit Command mode
1. Send CN command followed by a carriage return.
or:
2. If the device does not receive any valid AT commands within the time specified by CT
(Command Mode Timeout), it returns to the mode that the device was last in.
Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide
82
Sleep modes
About sleep modes
Normal mode
Pin sleep mode
Cyclic sleep mode
Cyclic sleep with pin wake up mode
Airplane mode
Connected sleep mode
The sleep timer
MicroPython sleep behavior
Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide
84
84
84
84
84
84
84
85
85
83
Sleep modes
About sleep modes
About sleep modes
A number of low-power modes exist to enable devices to operate for extended periods of time on
battery power. Use SM (Sleep Mode) to enable these sleep modes.
Normal mode
Set SM to 0 to enter Normal mode.
Normal mode is the default sleep mode. If a device is in this mode, it does not sleep and is always
awake.
Devices in Normal mode are typically mains powered.
Pin sleep mode
Set SM to 1 to enter pin sleep mode.
Pin sleep allows the device to sleep and wake according to the state of the SLEEP_RQ pin (SLEEP_RQ).
When you assert SLEEP_RQ (high), the device finishes any transmit or receive operations, closes any
active connection, and enters a low-power state.
When you de-assert SLEEP_RQ (low), the device wakes from pin sleep.
Cyclic sleep mode
Set SM to 4 to enter Cyclic sleep mode.
Cyclic sleep allows the device to sleep for a specific time and wake for a short time to poll.
If you use the D7 command to enable hardware flow control, the CTS pin asserts (low) when the
device wakes and can receive serial data, and de-asserts (high) when the device sleeps.
Cyclic sleep with pin wake up mode
Set SM to 5 to enter Cyclic sleep with pin wake up mode.
This mode is a slight variation on Cyclic sleep mode (SM = 4) that allows you to wake a device
prematurely by de-asserting the SLEEP_RQ pin (SLEEP_RQ).
In this mode, you can wake the device after the sleep period expires, or if a high-to-low transition
occurs on the SLEEP_RQ pin.
Airplane mode
While not technically a sleep mode, airplane mode is another way of saving power. When set, the
cellular component of the XBee Smart Modem is fully turned off and no access to the cellular network
is performed or possible. Use AM (Airplane Mode) to configure this mode.
Connected sleep mode
XBee Smart Modem hardware part number XB3-C-A1-UT-xxx can enter Connected sleep mode.
Set bit 0 of SO (Sleep Options) for connected sleep. When bit 0 is set and the XBee Smart Modem goes
to sleep, instead of the cellular component shutting down, it enters a lower power consumption mode
that maintains registration with the cellular network. This allows significantly faster resumption of
communications when coming out of sleep at the cost of additional power used.
Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide
84
Sleep modes
The sleep timer
Connected sleep mode draws 9 mA during sleep and 11 mA average over time (including periodically
waking up to maintain connection).
The sleep timer
If the device receives serial or RF data in Cyclic sleep mode and Cyclic sleep with pin wake up modes
(SM = 4 or SM = 5), it starts a sleep timer (time until sleep).
n Use ST (Wake Time) to set the duration of the timer.
When the sleep timer expires the device returns to sleep.
MicroPython sleep behavior
When the XBee Smart Modem enters deep sleep mode, any MicroPython code currently executing is
suspended until the device comes out of sleep. When the XBee Smart Modem comes out of sleep
mode, MicroPython execution continues where it left off.
Upon entering deep sleep mode, the XBee Smart Modem closes any active UDP connections and turns
off the cellular component. As a result, any sockets that were opened in MicroPython prior to sleep
report as no longer being connected. This behavior appears the same as a typical socket
disconnection event will:
n socket.send raises OSError: ENOTCONN
socket.sendto raises OSError: ENOTCONN
socket.recv returns the empty string, the traditional end-of-file return value
socket.recvfrom returns an empty message, for example:
(b'', (
, ) ) The underlying UDP socket resources have been released at this point. Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide 85 Serial communication Serial interface Serial data UART data flow Serial buffers CTS flow control RTS flow control Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide 87 87 87 87 88 88 86 Serial communication Serial interface Serial interface The XBee Smart Modem interfaces to a host device through a serial port. The device can communicate through its serial port with: n Through logic and voltage compatible universal asynchronous receiver/transmitter (UART). Through a level translator to any serial device, for example, through an RS-232 or USB interface board. Through a serial peripheral interface (SPI) port. Serial data A device sends data to the XBee Smart Modem's UART through pin 3 DIN as an asynchronous serial signal. When the device is not transmitting data, the signals should idle high. For serial communication to occur, you must configure the UART of both devices (the microcontroller and the XBee Smart Modem) with compatible settings for the baud rate, parity, start bits, stop bits, and data bits. Each data byte consists of a start bit (low), 8 data bits (least significant bit first) and a stop bit (high). The following diagram illustrates the serial bit pattern of data passing through the device. The diagram shows UART data packet 0x1F (decimal number 31) as transmitted through the device. You can configure the UART baud rate, parity, and stop bits settings on the device with the BD, NB, and SB commands respectively. For more information, see Serial interfacing commands. In the rare case that a device has been configured with the UART disabled, you can recover the device to UART operation by holding DIN low at reset time. DIN forces a default configuration on the UART at 9600 baud and it brings the device up in Command mode on the UART port. You can then send the appropriate commands to the device to configure it for UART operation. If those parameters are written, the device comes up with the UART enabled on the next reset. UART data flow Devices that have a UART interface connect directly to the pins of the XBee Smart Modem as shown in the following figure. The figure shows system data flow in a UART-interfaced environment. Lowasserted signals have a horizontal line over the signal name. Serial buffers The XBee Smart Modem maintains internal buffers to collect serial and RF data that it receives. The serial receive buffer collects incoming serial characters and holds them until the device can process them. The serial transmit buffer collects the data it receives via the RF link until it transmits that data out the serial or SPI port. Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide 87 Serial communication CTS flow control CTS flow control We strongly encourage you to use flow control with the XBee Smart Modem to prevent buffer overruns. CTS flow control is enabled by default; you can disable it with D7 (DIO7/CTS). When the serial receive buffer fills with the number of bytes specified by FT (Flow Control Threshold), the device de-asserts CTS (sets it high) to signal the host device to stop sending serial data. The device re-asserts CTS when less than FT-32 bytes are in the UART receive buffer. Note Serial flow control is not possible when using the SPI port. RTS flow control If you set D6 (DIO6/RTS) to enable RTS flow control, the device does not send data in the serial transmit buffer out the DOUT pin as long as RTS is de-asserted (set high). Do not de-assert RTS for long periods of time or the serial transmit buffer will fill. Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide 88 AT commands MicroPython commands Special commands Cellular commands Network commands Addressing commands Serial interfacing commands I/O settings commands I/O sampling commands Sleep commands Command mode options Firmware version/information commands Diagnostic interface commands Execution commands Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide 90 91 92 95 97 100 102 110 110 112 112 114 116 89 AT commands MicroPython commands MicroPython commands The following commands relate to using MicroPython on the XBee Smart Modem. PS (Python Startup) Sets whether or not the XBee Smart Modem runs the stored Python code at startup. Range 0-1 Parameter Description Do not run stored Python code at startup. Run stored Python code at startup. Default PY (MicroPython Command) Interact with the XBee Smart Modem using MicroPython. PY is a command with sub-commands. These sub-commands are arguments to PY. PYC(Code Report) You can store compiled code in flash using the Ctrl-F command from the MicroPython REPL; refer to the Digi MicroPython Programming Guide. The PYC sub-command reports details of the stored code. In Command mode, it returns three lines of text, for example: source: 1662 bytes (hash=0xC3B3A813) bytecode: 619 bytes (hash=0x0900DBCE) compiled: 2017-05-09T15:49:44 The messages are: n source: the size of the source code used to generate the bytecode and its 32-bit hash. bytecode: the size of bytecode stored in flash and its 32-bit hash. A size of 0 indicates that there is no stored code. compiled: a compilation timestamp. A timestamp of 2000-01-01T00:00:00 indicates that the clock was not set during compilation. In API mode, PYC returns five 32-bit big-endian values: n source size source hash bytecode size bytecode hash timestamp as seconds since 2000-01-01T00:00:00 Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide 90 AT commands Special commands PYD (Delete Code) PYD interrupts any running code, erases any stored code and then does a soft-reboot on the MicroPython subsystem. PYV (Version Report) Report the MicroPython version. PY^ (Interrupt Program) Sends KeyboardInterrupt to MicroPython. This is useful if there is a runaway MicroPython program and you have filled the stdin buffer. You can enter Command mode (+++) and send ATPY^ to interrupt the program. Default N/A Special commands The following commands are special commands. AC (Apply Changes) Immediately applies new settings without exiting Command mode. Applying changes means that the device re-initializes based on changes made to its parameter values. Once changes are applied, the device immediately operates according to the new parameter values. This behavior is in contrast to issuing the WR (Write) command. The WR command saves parameter values to non-volatile memory, but the device still operates according to previously saved values until the device is rebooted or you issue the CN (Exit AT Command Mode) or AC commands. Parameter range N/A Default N/A FR (Force Reset) Resets the device. The device responds immediately with an OK and performs a reset 100 ms later. If you issue FR while the device is in Command Mode, the reset effectively exits Command mode. Note We recommend entering Airplane mode before resetting or rebooting the device to allow the cellular module to detach from the network. Parameter range N/A Default N/A Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide 91 AT commands Cellular commands RE command Restore device parameters to factory defaults. The RE command does not write restored values to non-volatile (persistent) memory. Issue the WR (Write) command after issuing the RE command to save restored parameter values to non-volatile memory. Parameter range N/A Default N/A WR command Writes parameter values to non-volatile memory so that parameter modifications persist through subsequent resets. Note Once you issue a WR command, do not send any additional characters to the device until after you receive the OK response. Parameter range N/A Default N/A Cellular commands The following AT commands are cellular configuration and data commands. PH (Phone Number) Reads the SIM card phone number. If PH is blank, the XBee Smart Modem is not registered to the network. Parameter range N/A Default Set by the cellular carrier via the SIM card S# (ICCID) Reads the Integrated Circuit Card Identifier (ICCID) of the inserted SIM. Parameter range N/A Default Set by the SIM card Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide 92 AT commands Cellular commands IM (IMEI) Reads the device's International Mobile Equipment Identity (IMEI). Parameter range N/A Default Set in the factory MN (Operator) Reads the network operator on which the device is registered. Parameter range N/A Default AT&T MV (Modem Firmware Version) Read the firmware version string for cellular component communications. See the related VR (Firmware Version) command. Parameter range N/A Default Set in the currently loaded firmware DB (Cellular Signal Strength) Reads the absolute value of the current signal strength to the cell tower in dB. If DB is blank, the XBee Smart Modem has not received a signal strength from the cellular component. Parameter range 0x71 - 0x33 (-113 dBm to -51 dBm) [read-only] Default N/A AN (Access Point Name) Specifies the packet data network that the modem uses for Internet connectivity. This information is provided by your cellular network operator. After you set this value, applying changes with AC (Apply Changes) or CN (Exit Command mode) triggers a network reset. Parameter range 1 - 100 ASCII characters Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide 93 AT commands Cellular commands Default OA (Operating APN) Reads the APN value currently configured in the cellular component. Parameter range ASCII characters Default N/A AM (Airplane Mode) When set, the cellular component of the XBee Smart Modem is fully turned off and no access to the cellular network is performed or possible. Parameter range 0-1 0 = Normal operation 1 = Airplane mode Default DV (Antenna Diversity) Set and read the antenna diversity setting of the cellular component. When enabled, the cellular component uses both antennas to improve receive sensitivity. This setting is applied only while the XBee Smart Modem is initializing the cellular component. After changing this setting, you must: 1. Use WR command to write all values to flash. 2. Use FR (Force Reset) to reset the device. 3. Wait for the cellular component to be initialized: AI (Association Indication) reaches 0x00. 4. Use FR to reset the device a second time. 5. Wait again for the cellular component to initialize: AI reaches 0x00. Parameter range 0-1 0 - diversity disabled 1 - diversity enabled Default Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide 94 AT commands Network commands Network commands The following commands are network commands. IP (IP Protocol) Sets or displays the IP protocol used for client and server socket connections in IP socket mode. Parameter range 0-4 Value Description 0x00 UDP 0x01 TCP 0x02 SMS 0x03 Reserved 0x04 SSL over TCP communication Default 0x01 TL (SSL/TLS Protocol Version) Sets the SSL/TLS protocol version used for the SSL socket. If you change the TL value, it does not affect any currently open sockets. The value only applies to subsequently opened sockets. Note Due to known vulnerabilities in prior protocol versions, we strongly recommend that you use the latest TLS version whenever possible. Range Value Description 0x00 SSL v3 0x01 TLS v1.0 0x02 TLS v1.1 0x03 TLS v1.2 Default 0x03 TM (IP Client Connection Timeout) The IP client connection timeout. If there is no activity for this timeout then the connection is closed. If TM is 0, the connection is closed immediately after the device sends data. Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide 95 AT commands Network commands If you change the TM value while in Transparent Mode, the current connection is immediately closed. Upon the next transmission, the TM value applies to the newly created socket. If you change the TM value while in API Mode, the value only applies to subsequently opened sockets. Parameter range 0 - 0xFFFF [x 100 ms] Default 0xBB8 (5 minutes) TS (IP Server Connection Timeout) The IP server connection timeout. If no activity for this timeout then the connection is closed. When set to 0 the connection is closed immediately after data is sent.] Parameter Range 10 - 0xFFFF; (x 100 ms) Default 3000 DO (Device Options) Enables and disables special features on the XBee Smart Modem according to the following table. Bit 0 - Remote Manager support If the XBee Smart Modem cannot establish a connection with Remote Manager , it waits 30 seconds before trying again. On each successive connection failure, the wait time doubles (60 seconds, 120, 240, and so on) up to a maximum of 1 hour. This time resets to 30 seconds once the connection to Remote Manager succeeds or if the device is reset. Bits 1 - 7 Reserved Range 0x00 - 0x07 Value Description 0x00 Disable Remote Manager support. 0x01 Enable Remote Manager support. Default 0x01 EQ (Device Cloud FQDN) Sets or display the fully qualified domain name of the Remote Manager server. Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide 96 AT commands Addressing commands Range From 0 through 63 ASCII characters. Default my.devicecloud.com Addressing commands The following AT commands are addressing commands. SH (Serial Number High) The upper digits of the unique International Mobile Equipment Identity (IMEI) assigned to this device. Parameter range 0 - 0xFFFFFFFF [read-only] Default N/A SL (Serial Number Low) The lower digits of the unique International Mobile Equipment Identity (IMEI) assigned to this device. Parameter range 0 - 0xFFFFFFFF [read-only] Default N/A DL (Destination Address) The destination IPv4 address or fully qualified domain name. To set the destination address to an IP address, the value must be a dotted quad, for example XXX.XXX.XXX.XXX. To set the destination address to a domain name, the value must be a legal Internet host name, for example remotemanager.digi.com Parameter range 0 - 128 ASCII characters Default 0.0.0.0 P# (Destination Phone Number) Sets or displays the destination phone number used for SMS when IP (IP Protocol) = 2. Phone numbers must be fully numeric, 7 to 20 ASCII digits, for example: 8889991234. Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide 97 AT commands Addressing commands P# allows international numbers with or without the + prefix. If you omit + and are dialing internationally, you need to include the proper International Dialing Prefix for your calling region, for example, 011 for the United States. Range 7 - 20 ASCII digits including an optional + prefix Default N/A N1 (DNS Address) Displays the IPv4 address of the primary domain name server. Parameter Range Read-only Default 0.0.0.0 (waiting on cellular connection) N2 (DNS Address) Displays the IPv4 address of the secondary domain name server. Parameter Range Read-only Default 0.0.0.0 (waiting on cellular connection) DE (Destination Port) Sets or displays the destination IP port number. Parameter range 0x0 - 0xFFFF Default 0x2616 TD (Text Delimiter) The ASCII character used as a text delimiter for Transparent mode. When you select a character, information received over the serial port in Transparent mode is not transmitted until that character is received. To use a carriage return, set to 0xD. Set to zero to disable text delimiter checking. Parameter range 0 - 0xFF Default 0x0 Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide 98 AT commands Addressing commands MY (Module IP Address) Reads the device's IP address. This command is read-only because the IP address is assigned by the mobile network. In API mode, the address is represented as the binary four byte big-endian numeric value representing the IPv4 address. In Transparent or Command mode, the address is represented as a dotted-quad string notation. Parameter range 0- 15 IPv4 characters Default 0.0.0.0 LA (Lookup IP Address of FQDN) Performs a DNS lookup of the given fully qualified domain name (FQDN) and outputs its IP address. When you issue the command in API mode, the IP address is formatted in binary four byte big-endian numeric value. In all other cases (for example, Command mode) the format is dotted decimal notation. Range Valid FQDN Default OD (Operating Destination Address) Read the destination IPv4 address currently in use by Transparent mode. The value is 0.0.0.0 if no Transparent IP connection is active. In API mode, the address is represented as the binary four byte big-endian numeric value representing the IPv4 address. In Transparent or Command mode, the address is represented as a dotted-quad string notation. Parameter range Default 0.0.0.0 C0 (Source Port) Set or get the port number used to provide the serial communication service. Data received by this port on the network is transmitted on the XBee Smart Modem's serial port. As long as a network connection is established to this port (for TCP) data received on the serial port is transmitted on the established network connection. IP (IP Protocol) sets the protocol used when UART is in Transparent or API mode. For more information on using incoming connections, see Socket behavior. Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide 99 AT commands Serial interfacing commands Parameter range 0 - 0xFFFF Value Description Disabled Non-0 Enabled on that port Default Serial interfacing commands The following AT commands are serial interfacing commands. BD (Baud Rate) Sets or displays the serial interface baud rate for communication between the device's serial port and the host. Modified interface baud rates do not take effect until the XBee Smart Modem exits Command mode or you issue AC (Apply Changes). The baud rate resets to default unless you save it with WR command or by clicking the Write module settings button in XCTU. Parameter range Standard baud rates: 0x1 - 0x8 Non-standard baud rates: 0x5B9 to 0x3D090 (250,000 b/s) Parameter Description 0x0 1200 b/s 0x1 2400 b/s 0x2 4800 b/s 0x3 9600 b/s 0x4 19200 b/s 0x5 38400 b/s 0x6 57600 b/s 0x7 115200 b/s 0x8 230400 b/s Default 0x3 (9600 b/s) Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide 100 AT commands Serial interfacing commands NB (Parity) Set or read the serial parity settings for UART communications. Parameter range 0x00 - 0x02 Parameter Description 0x00 No parity 0x01 Even parity 0x02 Odd parity Default 0x00 SB (Stop Bits) Sets or displays the number of stop bits for UART communications. Parameter range 0-1 Parameter Configuration One stop bit Two stop bits Default RO (Packetization Timeout) Set or read the number of character times of inter-character silence required before transmission begins when operating in Transparent mode. RF transmission also starts after 100 bytes (maximum packet size) are received in the DI buffer. Set RO to 0 to transmit characters as they arrive instead of buffering them into one RF packet. Set to FF for realtime typing by humans. Also, see TD (Text Delimiter). Parameter range 0 - 0xFF (x character times) Default FT (Flow Control Threshold) Set or display the flow control threshold. Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide 101 AT commands I/O settings commands The device de-asserts CTS when FT bytes are in the UART receive buffer. Parameter range 0x9D - 0x82D Default 0x681 AP (API Enable) The API mode setting. The device can format the RF packets it receives into API frames and send them out the UART. When API is enabled the UART data must be formatted as API frames because Transparent mode is disabled. See Modes for more information. Parameter range 0x00 - 0x05 Parameter Description 0x00 API disabled (operate in Transparent mode) 0x01 API enabled 0x02 API enabled (with escaped control characters) 0x03 N/A 0x04 MicroPython REPL 0x05 Bypass mode Default I/O settings commands The following AT commands are I/O settings commands. D0 (DIO0/AD0) Sets or displays the DIO0/AD0 configuration (pin 20). Parameter range 0, 2 - 5 Parameter Description Disabled N/A Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide 102 AT commands I/O settings commands Parameter Description Analog input Digital input Digital output, default low Digital output, default high Default D1 (DIO1/AD1) Sets or displays the DIO1/AD1 configuration (pin 19). Parameter range 0-6 Parameter Description Disabled SPI_ATTN ADC Digital input Digital output, low Digital output, high I2C SCL Default D2 (DIO2/AD2) Sets or displays the DIO2/AD2 configuration (pin 18). Parameter range 0-5 Description Disabled SPI_CLK Analog input Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide 103 AT commands I/O settings commands Description Digital input Digital output, default low Digital output, default high Default D3 (DIO3/AD3) Sets or displays the DIO3/AD3 configuration (pin 17). Parameter range 0-5 Parameter Description Disabled SPI_SSEL Analog input Digital input Digital output, default low Digital output, default high Default D4 (DIO4) Sets or displays the DIO4 configuration (pin 11). Parameter range 0, 1, 3 - 5 Parameter Description Disabled SPI_MOSI N/A Digital input Digital output, default low Digital output, default high Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide 104 AT commands I/O settings commands Default D5 (DIO5/ASSOCIATED_INDICATOR) Sets or displays the DIO5/ASSOCIATED_INDICATOR configuration (pin 15). Parameter range 0, 1, 3 - 5 Parameter Description Disabled Associated LED N/A Digital input Digital output, default low Digital output, default high Default D6 (DIO6/RTS) Sets or displays the DIO6/RTS configuration (pin 16). Parameter range 0, 1, 3 - 5 Parameter Description Disabled RTS flow control N/A Digital input Digital output, default low Digital output, default high Default D7 (DIO7/CTS) Sets or displays the DIO7/CTS configuration (pin 12). Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide 105 AT commands I/O settings commands Parameter range 0, 1, 3 - 5 Parameter Description Disabled CTS flow control N/A Digital input Digital output, default low Digital output, default high Default 0x1 D8 (DIO8/SLEEP_REQUEST) Sets or displays the DIO8/DTR/SLP_RQ configuration (pin 9). Parameter range 0, 1, 3 - 5 Parameter Description Disabled SLEEP_REQUEST input Digital input Digital output, default low Digital output, default high Default Sets or displays the DIO9/ON_SLEEP configuration (pin 13). Parameter range 0, 1, 3 - 5 Parameter Description Disabled ON/SLEEP output Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide 106 AT commands I/O settings commands Parameter Description Digital input Digital output, default low Digital output, default high Default P0 (DIO10/PWM0 Configuration) Sets or displays the PWM/DIO10 configuration (pin 6). This command enables the option of translating incoming data to a PWM so that the output can be translated back into analog form. Parameter range 0-5 Parameter Description Disabled RSSI PWM0 output PWM0 output Digital input Digital output, low Digital output, high Default P1 (DIO11/PWM1 Configuration) Sets or displays the DIO11 configuration (pin 7). Parameter range 0, 1, 3 - 6 Parameter Description Disabled Fan enable. Output is low when the XBee Smart Modem is sleeping, turning an attached fan off when the cellular component is in a power saving mode, and also during Airplane Mode Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide 107 AT commands I/O settings commands Parameter Description Digital input Digital output, default low Digital output, default high I2C SDA USB direct Default P2 (DIO12 Configuration) Sets or displays the DIO12 configuration (pin 4). Parameter range 0, 1, 3 - 5 Parameter Description Disabled SPI_MISO N/A Digital input Digital output, default low Digital output, default high Default PD (Pull Direction) The resistor pull direction bit field (1 = pull-up, 0 = pull-down) for corresponding I/O lines that are set by PR (Pull-up/down Resistor Enable). If the bit is not set in PR, the device uses PD. Note Resistors are not applied to disabled lines. See PR (Pull-up/down Resistor Enable) for bit mappings, which are the same. Parameter range 0x0 – 0x7FFF Default 0 – 0x7FFF Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide 108 AT commands I/O settings commands PR (Pull-up/down Resistor Enable) Sets or displays the bit field that configures the internal resistor status for the digital input lines. Internal pull-up/down resistors are not available for digital output pins, analog input pins, or for disabled pins. Use the PD command to specify whether the resistor is pull-up or pull-down. n If you set a PR bit to 1, it enables the pull-up/down resistor If you set a PR bit to 0, it specifies no internal pull-up/down resistor. The following table defines the bit-field map for both the PR and PD commands. Bit I/O line Module pin DIO4 pin 11 DIO3/AD3 pin 17 DIO2/AD2 pin 18 DIO1/AD1 pin 19 DIO0/AD0 pin 20 DIO6/RTS pin 16 DIO8/SLEEP_REQUEST pin 9 DIO14/DIN pin 3 DIO5/ASSOCIATE pin 15 DIO9/On/SLEEP pin 13 10 DIO12 pin 4 11 DIO10 pin 6 12 DIO11 pin 7 13 DIO7/CTS pin 12 14 DIO13/DOUT pin 17 Parameter range 0 - 0x7FFF (bit field) Default 0x7FFF M0 (PWM0 Duty Cycle) Sets the duty cycle of PWM0 (pin 6) for P0 = 2, where a value of 0x200 is a 50% duty cycle. Before setting the line as an output: 1. Enable PWM0 output (P0 (DIO10/PWM0 Configuration) = 2). 2. Apply the settings (use CN command or AC (Apply Changes)). Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide 109 AT commands I/O sampling commands The PWM period is 42.62 µs and there are 0x03FF (1023 decimal) steps within this period. When M0 = 0 (0% PWM), 0x01FF (50% PWM), 0x03FF (100% PWM), and so forth. Parameter range 0 - 0x3FF Default I/O sampling commands The following AT commands configure I/O sampling parameters. TP (Temperature) Displays the temperature of the XBee Smart Modem in degrees Celsius. The temperature value is displayed in 8-bit two’s compliment format. For example, 0x1A = 26 °C, and 0xF6 = -10 °C. Parameter range 0 - 0xFF which indicates degrees Celsius displayed in 8-bit two's compliment format. Default N/A Sleep commands The following AT commands are sleep commands. SM (Sleep Mode) Sets or displays the sleep mode of the device. The sleep mode determines how the device enters and exits a power saving sleep. Sleep mode is also affected by the SO command, option bit 6. See Sleep modes for more information about sleep modes. Parameter range 0, 1, 4, 5 Parameter Description Normal. In this mode the device never sleeps. Pin Sleep. In this mode the device honors the SLEEP_RQ pin. Set D8 (DIO8/SLEEP_REQUEST) to the sleep request function: 1. Cyclic Sleep. In this mode the device repeatedly sleeps for the value specified by SP and spends ST time awake. Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide 110 AT commands Sleep commands Parameter Description Cyclic Sleep with Pin Wake. In this mode the device acts as in Cyclic Sleep but does not sleep if the SLEEP_RQ pin is inactive, allowing the device to be kept awake or woken by the connected system. Default SP (Sleep Period) Sets or displays the time to spend asleep in cyclic sleep modes. In Cyclic sleep mode, the node sleeps with CTS disabled for the sleep time interval, then wakes for the wake time interval. Parameter range 0x1 - 0x83D600 (x 10 ms) Default 0x7530 (5 minutes) ST (Wake Time) Sets or displays the time to spend awake in cyclic sleep modes. Parameter range 0x1 - 0x36EE80 (x 1 ms) Default 0xEA60 (60 seconds) SO (Sleep Options) Set or read the sleep options bit field of a device. This command is a bitmask. Parameter range 0x0 - 0xFFFF Bit field: Bit Setting Meaning 0x00 0 Description Connected On compatible hardware, enters a lower power consumption mode sleep that maintains registration with the cellular network. Set all other option bits to 0. Default Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide 111 AT commands Command mode options Command mode options The following commands are Command mode option commands. CC (Command Sequence Character) The character value the device uses to enter Command mode. The default value (0x2B) is the ASCII code for the plus (+) character. You must enter it three times within the guard time to enter Command mode. To enter Command mode, there is also a required period of silence before and after the command sequence characters of the Command mode sequence (GT + CC + GT). The period of silence prevents inadvertently entering Command mode. Parameter range 0 - 0xFF Default 0x2B (the ASCII plus character: +) CT (Command Mode Timeout) Sets or displays the Command mode timeout parameter. If a device does not receive any valid commands within this time period, it returns to Idle mode from Command mode. Parameter range 2 - 0x1770 (x 100 ms) Default 0x64 (10 seconds) GT (Guard Times) Set the required period of silence before and after the command sequence characters of the Command mode sequence (GT + CC + GT). The period of silence prevents inadvertently entering Command mode. Parameter range 0x2 - 0x6D3 (x 1 ms) Default 0x3E8 (one second) Firmware version/information commands The following AT commands are firmware version/information commands. VR (Firmware Version) Reads the firmware version on a device. Parameter range 0 - 0xFFFF [read-only] Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide 112 AT commands Firmware version/information commands Default Set in firmware VL (Verbose Firmware Version) Shows detailed version information including the application build date and time. Parameter range N/A Default Set in firmware HV (Hardware Version) Display the hardware version number of the device. Parameter range 0 - 0xFFFF [read-only] Default Set in firmware AI (Association Indication) Reads the Association status code to monitor association progress. The following table provides the status codes and their meanings. Status code Meaning 0x00 Connected to the Internet. 0x22 Registering to cellular network. 0x23 Connecting to the Internet. 0x24 The cellular component is missing, corrupt, or otherwise in error. The cellular component requires a new firmware image. 0x25 Cellular network registration denied. 0x2A Airplane mode. 0x2B USB Direct active. 0x2F Bypass mode active. 0xFF Initializing. Parameter range 0 - 0xFF [read-only] Default N/A Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide 113 AT commands Diagnostic interface commands HS (Hardware Series) Read the device's hardware series number. Parameter range N/A Default Set in the firmware CK (Configuration CRC) Displays the cyclic redundancy check (CRC) of the current AT command configuration settings. Parameter range 0 - 0xFFFFFFFF Default N/A Diagnostic interface commands The following AT commands are diagnostic interface commands. DI (Device Cloud Indicator) Displays the current Remote Manager status for the XBee. Range Value Description 0x00 Connected 0x01 Before connection to the Internet 0x02 Remote Manager connection in progress 0x03 Disconnecting from Remote Manager 0x04 Not configured for Remote Manager Default N/A CI (Protocol/Connection Indication) Displays information regarding the last IP connection (when the IP command = 0, 1 or 4) or SMS transmission (when IP = 2). The value for this parameter resets to 0xFF when the device switches between IP (IP Protocol) modes. Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide 114 AT commands Diagnostic interface commands When IP is set to 0, 1, or 4 (UDP, TCP, over SSL over TCP), CI resets to 0xFF when you apply changes to any of the following settings: n DL (Destination Address) DE (Destination Port) TM (IP Client Connection Timeout) When IP is set to 2 (SMS), CI resets to 0xFF when P# (Destination Phone Number) is changed. The following table provides the parameter's meaning when IP = 0 for UDP connections. Parameter Description 0x00 The socket is open. 0x01 Tried to send but could not. 0x02 Invalid parameters (bad IP/host). 0x03 TCP not supported on this cellular component. 0x10 Not registered to the cell network. 0x11 Cellular component not identified yet. 0x12 DNS query lookup failure. 0x20 Bad handle. 0x21 User closed. 0x22 Unknown server - DNS lookup failed. 0x23 Connection lost. 0x24 Unknown. 0xFF No known status. The following table provides the parameter's meaning when IP = 1 or 4 for TCP connections. Parameter Description 0x00 The socket is open. 0x01 Tried to send but could not. 0x02 Invalid parameters (bad IP/host). 0x03 TCP not supported on this cellular component. 0x10 Not registered to the cell network. 0x11 Cellular component not identified yet. 0x12 DNS query lookup failure. 0x20 Bad handle. Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide 115 AT commands Execution commands Parameter Description 0x21 User closed. 0x22 No network registration. 0x23 No internet connection. 0x24 No server - timed out on connection. 0x25 Unknown server - DNS lookup failed. 0x26 Connection refused. 0x27 Connection lost. 0x28 Unknown. 0xFF No known status. The following table provides the parameter's meaning when IP = 2 for SMS connections. Parameter Description 0x00 SMS successfully sent. 0x01 SMS failed to send. 0x02 Invalid SMS parameters - check P# (Destination Phone Number). 0x03 SMS not supported. 0x10 No network registration. 0x11 Cellular component stack error. 0xFF No SMS state to report (no SMS messages have been sent). Parameter range 0 - 0xFF (read-only) Default Execution commands The location where most AT commands set or query register values, execution commands execute an action on the device. Execution commands are executed immediately and do not require changes to be applied. NR (Network Reset) NR resets the network layer parameters. The XBee Smart Modem responds immediately with an OK on the UART and then causes a network restart. If NR = 0, the XBee Smart Modem tears down any TCP/UDP sockets and resets Internet connectivity. Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide 116 AT commands Execution commands You can also send NR, which acts like NR = 0. Parameter range Default N/A !R (Modem Reset) Forces the cellular component to reboot. CAUTION! This command is for advanced users, and you should only use it if the cellular component becomes completely stuck while in Bypass mode. Normal users should never need to run this command. See the FR (Force Reset) command instead. Range N/A Default N/A IS (Force Sample) When run, IS reports the values of all of the enabled digital and analog input lines. If no lines are enabled for digital or analog input, the command returns an error. Command mode In Command mode, the response value is a multi-line format, individual lines are delimited with carriage returns, and the entire response terminates with two carriage returns. Each line is a series of ASCII characters representing a single number in hexadecimal notation. The interpretation of the lines is: n Number of samples. For legacy reasons this field always returns 1. Digital channel mask. A bit-mask of all I/O capable pins in the system. The bits set to 1 are configured for digital I/O and are included in the digital data value below. Pins D0 - D9 are bits 0 - 9, and P0 - P2 are bits 10 - 12. Analog channel mask. The bits set to 1 are configured for analog I/O and have individual readings following the digital data field. Digital data. The current digital value of all the pins set in the digital channel mask, only present if at least one bit is set in the digital channel mask. Analog data. Additional lines, one for each set pin in the analog channel mask. Each reading is a 10-bit ADC value for a 2.5 V voltage reference. API operating mode In API operating mode, IS immediately returns an OK response. Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide 117 AT commands Execution commands The API response is ordered identical to the Command mode response with the same fields present. Each field is a binary number of the size listed in the following table. Multi-byte fields are in big-endian byte order. Field Size Number of samples 1 byte Digital channel mask 2 bytes Analog chanel mask 1 byte Samples 2 bytes each Parameter range N/A Default N/A Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide 118 Operate in API mode API mode overview Use the AP command to set the operation mode API frame format Frame descriptions Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide 120 120 120 124 119 Operate in API mode API mode overview API mode overview As an alternative to Transparent operating mode, you can use API operating mode. API mode provides a structured interface where data is communicated through the serial interface in organized packets and in a determined order. This enables you to establish complex communication between devices without having to define your own protocol. The API specifies how commands, command responses and device status messages are sent and received from the device using the serial interface or the SPI interface. We may add new frame types to future versions of firmware, so build the ability to filter out additional API frames with unknown frame types into your software interface. Use the AP command to set the operation mode Use AP (API Enable) to specify the operation mode: AP command setting Description AP = 0 Transparent operating mode, UART serial line replacement with API modes disabled. This is the default option. AP = 1 API operation. AP = 2 API operation with escaped characters (only possible on UART). AP = 3 N/A AP = 4 MicroPython REPL AP = 5 Bypass mode. This mode is for direct communication with the underlying chip and is only for advanced users. The API data frame structure differs depending on what mode you choose. API frame format An API frame consists of the following: n Start delimeter Length Frame data Checksum API operation (AP parameter = 1) This is the recommended API mode for most applications. The following table shows the data frame structure when you enable this mode: Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide 120 Operate in API mode API frame format Frame fields Byte Description Start delimiter 0x7E Length 2-3 Most Significant Byte, Least Significant Byte Frame data 4 - number (n) API-specific structure Checksum n+1 1 byte Any data received prior to the start delimiter is silently discarded. If the frame is not received correctly or if the checksum fails, the XBee replies with a radio status frame indicating the nature of the failure. API operation with escaped characters (AP parameter = 2) Setting API to 2 allows escaped control characters in the API frame. Due to its increased complexity, we only recommend this API mode in specific circumstances. API 2 may help improve reliability if the serial interface to the device is unstable or malformed frames are frequently being generated. When operating in API 2, if an unescaped 0x7E byte is observed, it is treated as the start of a new API frame and all data received prior to this delimiter is silently discarded. For more information on using this API mode, see the Escaped Characters and API Mode 2 in the Digi Knowledge base. API escaped operating mode works similarly to API mode. The only difference is that when working in API escaped mode, the software must escape any payload bytes that match API frame specific data, such as the start-of-frame byte (0x7E). The following table shows the structure of an API frame with escaped characters: Frame fields Byte Description Start delimiter 1 0x7E Length 2-3 Most Significant Byte, Least Significant Byte Frame data 4-n API-specific structure Checksum n + 1 1 byte Characters escaped if needed Start delimiter field This field indicates the beginning of a frame. It is always 0x7E. This allows the device to easily detect a new incoming frame. Escaped characters in API frames If operating in API mode with escaped characters (AP parameter = 2), when sending or receiving a serial data frame, specific data values must be escaped (flagged) so they do not interfere with the data frame sequencing. To escape an interfering data byte, insert 0x7D and follow it with the byte to be escaped (XORed with 0x20). The following data bytes need to be escaped: n 0x7E: start delimiter 0x7D: escape character 0x11: XON 0x13: XOFF Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide 121 Operate in API mode API frame format To escape a character: 1. Insert 0x7D (escape character). 2. Append it with the byte you want to escape, XORed with 0x20. In API mode with escaped characters, the length field does not include any escape characters in the frame and the firmware calculates the checksum with non-escaped data. Example: escape an API frame To express the following API non-escaped frame in API operating mode with escaped characters: Frame Data Start delimiter Length Frame type Checksum Data 7E 00 0F 17 01 00 13 A2 00 40 AD 14 2E FF FE 02 4E 49 6D You must escape the 0x13 byte: 1. Insert a 0x7D. 2. XOR byte 0x13 with 0x20: 13 ⊕ 20 = 33 The following figure shows the resulting frame. Note that the length and checksum are the same as the non-escaped frame. Frame Data Start delimiter Length Frame type Checksum Data 7E 00 0F 17 01 00 7D 33 A2 00 40 AD 14 2E FF FE 02 4E 49 6D The length field has a two-byte value that specifies the number of bytes in the frame data field. It does not include the checksum field. Length field The length field is a two-byte value that specifies the number of bytes contained in the frame data field. It does not include the checksum field. Frame data This field contains the information that a device receives or will transmit. The structure of frame data depends on the purpose of the API frame: Frame data Length Data 0x7E MSB LSB ... n+1 Data Frame type is the API frame type identifier. It determines the type of API frame and indicates how the Data field organizes the information. Data contains the data itself. This information and its order depend on the what type of frame that the Frame type field defines. Multi-byte values are sent big-endian. Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide 122 Operate in API mode API frame format Calculate and verify checksums To calculate the checksum of an API frame: 1. Add all bytes of the packet, except the start delimiter 0x7E and the length (the second and third bytes). 2. Keep only the lowest 8 bits from the result. 3. Subtract this quantity from 0xFF. To verify the checksum of an API frame: 1. Add all bytes including the checksum; do not include the delimiter and length. 2. If the checksum is correct, the last two digits on the far right of the sum equal 0xFF. Example Consider the following sample data packet: 7E 00 0A 01 01 50 01 00 48 65 6C 6C 6F B8+ Byte(s) Description 7E Start delimeter 00 0A Length bytes 01 API identifier 01 API frame ID 50 01 Destination address low 00 Option byte 48 65 6C 6C 6F Data packet B8 Checksum To calculate the check sum you add all bytes of the packet, excluding the frame delimiter 7E and the length (the second and third bytes): 7E 00 0A 01 01 50 01 00 48 65 6C 6C 6F B8 Add these hex bytes: 01 + 01 + 50 + 01 + 00 + 48 + 65 + 6C + 6C + 6F = 247 Now take the result of 0x247 and keep only the lowest 8 bits which in this example is 0xC4 (the two far right digits). Subtract 0x47 from 0xFF and you get 0x3B (0xFF - 0xC4 = 0x3B). 0x3B is the checksum for this data packet. If an API data packet is composed with an incorrect checksum, the XBee Smart Modem will consider the packet invalid and will ignore the data. To verify the check sum of an API packet add all bytes including the checksum (do not include the delimiter and length) and if correct, the last two far right digits of the sum will equal FF. 01 + 01 + 50 + 01 + 00 + 48 + 65 + 6C + 6C + 6F + B8 = 2FF Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide 123 Operate in API mode Frame descriptions Frame descriptions The following sections describe the API frames. AT Command - 0x08 Description Use this frame to query or set parameters on the local device. Changes this frame makes to device parameters take effect after executing the AT command. Format The following table provides the contents of the frame. For details on frame structure, see API frame format. Field name Field Data value type Description Frame type 0x08 Byte Frame ID Byte Identifies the data frame for the host to correlate with a subsequent ACK. If set to 0, the device does not send a response. AT command Byte Command name: two ASCII characters that identify the AT command. Parameter value Byte If present, indicates the requested parameter value to set the given register. If no characters are present, it queries the register. Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide 124 Operate in API mode Frame descriptions Transmit (TX) SMS - 0x1F Description Transmit an SMS message. The frame allows international numbers with or without the + prefix. If you omit + and are dialing internationally, you need to include the proper International Dialing Prefix for your calling region, for example, 011 for the United States. Format The following table provides the contents of the frame. For details on frame structure, see API frame format. Field name Field value Data type Description Frame type 0x1F Byte Frame ID Byte Reference identifier used to match status responses. 0 disables the TX Status frame. Options Byte Reserved for future use. Phone number 20 byte string String representation of phone number terminated with a null (0x0) byte. Use numbers and the + symbol only, no other symbols or letters. Payload Variable Data to send as the body of the SMS message. (160 characters maximum) Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide 125 Operate in API mode Frame descriptions Transmit (TX) Request: IPv4 - 0x20 Description A TX Request message causes the device to transmit data in IPv4 format. A TX request frame for a new destination creates a network socket. After the network socket is established, data from the network that is received on the socket is sent out the device's serial port in the form of a Receive (RX) Packet frame. Format The following table provides the contents of the frame. For details on frame structure, see API frame format. Field name Field value Data type Description Frame type 0x20 Byte Frame ID Byte Reference identifier used to match status responses. 0 disables the TX Status frame. Destination address 32-bit big endian Destination port 16-bit big endian Source port 16-bit If the source port is 0, the device attempts to send the frame big endian data using an existing open socket with a destination that matches the destination address and destination port fields of this frame. If there is no matching socket, then the device attempts to open a new socket. If the source port is non-zero, the device attempts to send the frame data using an existing open socket with a source and destination that matches the source port, destination address, and destination port fields of this frame. If there is no matching socket, it returns an error. Protocol Byte 0 = UDP 1 = TCP 4 = SSL over TCP Transmit options Byte bitfield Bit fields are offset 0 Bit field 0 - 7. Bits 0, and 2-7 are reserved, bit 1 is not. BIT 1 = 1 - Terminate the TCP socket after transmission is complete 0 - Leave the socket open. Closed by timeout, see TM (IP Client Connection Timeout). Ignore this bit for UDP packets. All other bits are reserved and should be 0. Payload Variable Data to be transferred to the destination, may be up to 1500 bytes. Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide 126 Operate in API mode Frame descriptions AT Command Response - 0x88 Description A device sends this frame in response to an AT Command (0x08) frame. Some commands send back multiple frames. Format The following table provides the contents of the frame. For details on frame structure, see API frame format. Field name Field Data value type Frame type 0x88 Description Byte Frame ID Byte Identifies the data frame for the host to correlate with a subsequent ACK. If set to 0, the device does not send a response. AT command Byte Command name: two ASCII characters that identify the AT command. Byte 0 = OK 1 = ERROR 2 = Invalid command 3 = Invalid parameter Byte Register data in binary format. If the register was set, then this field is not returned. Status Parameter value ## Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide 127 Operate in API mode Frame descriptions Transmit (TX) Status - 0x89 Description Indicates the success or failure of a transmit operation. Format The following table provides the contents of the frame. For details on frame structure, see API frame format. Field name Field value Data type Description Frame type 0x89 Byte Frame ID Byte Refers to the frame ID specified in a previous transmit frame Status Byte Status code (see the table below) The following table shows the status codes. Code Description 0x0 Successful transmit 0x21 Failure to transmit to cell network 0x22 Not registered to cell network 0x2c Invalid frame values (check the phone number) 0x31 Internal error 0x32 Resource error (retry operation later) 0x74 Message too long 0x78 Invalid UDP port 0x79 Invalid TCP port 0x7A Invalid host address 0x7B Invalid data mode 0x80 Connection refused 0x81 Socket connection lost 0x82 No server 0x83 Socket closed 0x84 Unknown server 0x85 Unknown error Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide 128 Operate in API mode Frame descriptions Modem Status - 0x8A Description Cellular component status messages are sent from the device in response to specific conditions. Format The following table provides the contents of the frame. For details on frame structure, see API frame format. Field name Field value Data type Frame type 0x8A Byte Status ## Byte Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide Description 0 = Hardware reset or power up 1 = Watchdog timer reset 2 = Registered with cellular network 3 = Unregistered with cellular network 0x0E = Remote Manager connected 0x0F = Remote Manager disconnected 129 Operate in API mode Frame descriptions Receive (RX) Packet: SMS - 0x9F Description This XBee Smart Modem uses this frame when it receives an SMS message. Format The following table provides the contents of the frame. For details on frame structure, see API frame format. Field name Field value Data type Frame Type 0x9F Byte Description Phone number 20 byte string String representation of the phone number, padded out with null bytes (0x0). Payload Variable Body of the received SMS message. Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide 130 Operate in API mode Frame descriptions Receive (RX) Packet: IPv4 - 0xB0 Description The XBee Smart Modem uses this frame when it receives RF data on a network socket that is created by a TX request frame or configuring C0 (Source Port). Format The following table provides the contents of the frame. For details on frame structure, see API frame format. Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide 131 Socket behavior Supported sockets Secure Sockets Layer (SSL) certificate checking Socket timeouts Socket limits in API mode Enable incoming TCP connections API mode behavior for outgoing TCP and SSL connections API mode behavior for outgoing UDP data API mode behavior for incoming TCP connections API mode behavior for incoming UDP data Transparent mode behavior for outgoing TCP and SSL connections Transparent mode behavior for outgoing UDP data Transparent mode behavior for incoming TCP connections Transparent mode behavior for incoming UDP connections Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide 133 133 133 133 133 134 134 135 135 135 136 136 136 132 Socket behavior Supported sockets Supported sockets The XBee Smart Modem supports the following number of sockets: n 10 maximum: some combination of 6 TCP, 6 UDP, 6 SSL.1 Secure Sockets Layer (SSL) certificate checking Currently, the XBee Smart Modem is not capable of checking the certificate of the remote end of the socket connection. We will add this support in the future. This means that the device cannot authenticate the remote end of the connection. Although the connection is encrypted, there is no way to verify that the remote server is the expected server. Socket timeouts The XBee Smart Modem implicitly opens the socket any time there is data to be sent, and closes it according to the timeout settings. The TM (IP Client Connection Timeout) command controls the timeout settings. Socket limits in API mode There are a fixed number of sockets that can be created which varies by device variant and protocol. When a Transmit (TX) Request: IPv4 - 0x20 frame is sent to the XBee Smart Modem for a new destination, it creates a new socket. The exception to this is when using the UDP protocol with the C0 source port, which allows unlimited destinations on the socket created by C0 (Source Port). If no more sockets are available, the device sends back a Transmit (TX) Status - 0x89 frame with a Resource Error. The Resource Error resolves when an existing socket is closed. An existing socket may be closed when the socket times out (see TM (IP Client Connection Timeout) and TS (IP Server Connection Timeout)) or when the socket is closed via a TX request with the CLOSE flag set. Enable incoming TCP connections TCP establishes virtual connections between the XBee Smart Modem and other devices. You can enable the XBee Smart Modem to listen for incoming TCP connections. Listen means waiting for a connection request from any remote TCP and port.2 The following devices support incoming TCP connections: n Part number: XBC-V1-UT-001 (Digi XBee Cellular Verizon LTE Cat 1) Part number: XBC-M1-UT-001 (Digi XBee Cellular AT&T LTE Cat 1) Part number: XB3-C-A1-UT-xxx (Digi XBee3 Cellular AT&T LTE Cat 1) The XBee Smart Modem only supports incoming TCP connections, not UDP or SSL. To enable incoming connections in XCTU: 11 UDP socket is always reserved for DNS, so subtract 1 socket from the values above. 2See https://tools.ietf.org/html/rfc793. Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide 133 Socket behavior API mode behavior for outgoing TCP and SSL connections 1. Set AP (API Enable) to Transparent Mode [0]. 2. Set C0 (Source Port) to the value of the TCP port that the device listens on. 3. Click the Write button API mode behavior for outgoing TCP and SSL connections To initiate an outgoing TCP or SSL connection to a remote host, send a Transmit (TX) Request: IPv4 0x20 frame to the XBee Smart Modem's serial port specifying the destination address and destination port for the remote host; the data is optional and the source port is 0. If the connection is disconnected at any time, send a Transmit TX Request frame to trigger a new connection attempt. To send data over this connection use the Transmit (TX) Request: IPv4 - 0x20. The device sends a Transmit (TX) Status - 0x89 frame in reply to the Transmit TX Request indicating the status of the request. A status of 0 indicates the connection and/or data was successful and a non-zero value indicates a failure. Any data received on the connection is sent out the XBee Smart Modem's serial port as a Receive RX frame. A connection is closed when: n The remote end closes the connection. No data is sent or received for longer than the socket timeout set by TM (IP Client Connection Timeout). A Transmit TX Request is sent with the CLOSE flag set. API mode behavior for outgoing UDP data To send a UDP datagram to a remote host, send a Transmit (TX) Request: IPv4 - 0x20 frame to the XBee Smart Modem's serial port specifying the destination address and destination port of the remote host. If you use a source port of 0, the device creates a new socket for the purpose of sending to the remote host. The XBee Smart Modem supports a finite number of sockets, so if you need to send to many destinations: 1. The socket must be closed after use. or 2. You must use the socket specified by the C0 (Source Port) setting. To use the socket specified by the C0 setting, in the Transmit TX request frame use a source port that matches the value configured for the C0 setting. The device sends a Transmit (TX) Status - 0x89 frame in reply to the Transmit TX Request to indicate the status of the request. A status of 0 indicates the data was successfully sent out of the device and a non-zero value indicates a failure. Any data received on the UDP socket is sent out the XBee Smart Modem's serial port as a Receive (RX) Packet: IPv4 - 0xB0 frame. A UDP socket is closed when: n No data has been sent or received for longer than the socket timeout set by TM (IP Client Connection Timeout). A transmit TX Request is sent with the CLOSE flag set. Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide 134 Socket behavior API mode behavior for incoming TCP connections API mode behavior for incoming TCP connections For incoming connections and data in API mode, the XBee Smart Modem uses the C0 (Source Port) and IP (IP Protocol) settings to specify the listening port and protocol used. The XBee Smart Modem does not currently support the SSL protocol for incoming connections. When the IP setting is TCP the XBee Smart Modem allows multiple incoming TCP connections on the port specified by the C0 setting. Any data received on the connection is sent out the XBee Smart Modem's serial port as a Receive (RX) Packet: IPv4 - 0xB0 frame. To send data from the device over the connection, use the Transmit (TX) Request: IPv4 - 0x20 frame with the corresponding address fields received from the Receive RX frame. In other words: n Take the source address, source port, and destination port fields from the Receive (RX) frame and use those respectively as: The destination address, destination port, and source port fields for the Transmit (TX) Request frame. A connection is closed when: n The remote end closes the connection. No data has been sent or received for longer than the socket timeout set by TS (IP Server Connection Timeout). A Transmit (TX) Request frame is sent with the CLOSE flag set. API mode behavior for incoming UDP data When the IP (IP Protocol) setting is UDP, any data sent from a remote host to the XBee Smart Modem's network port specified by the C0 (Source Port) setting is sent out the XBee Smart Modem's serial port as a Receive (RX) Packet: IPv4 - 0xB0 frame. To send data from the XBee Smart Modem to the remote destination, use the Transmit (TX) Request: IPv4 - 0x20 frame with the corresponding address fields received from the Receive RX frame. In other words take the source address, source port, and destination port fields from the Receive (RX) frame and use those respectively as the destination address, destination port, and source port fields for the Transmit (TX) Request frame. Transparent mode behavior for outgoing TCP and SSL connections For Transparent mode, the IP (IP Protocol) setting specifies the protocol and the DL (Destination Address) and DE (Destination Port) settings specify the destination address used for outgoing data (UDP) and outgoing connections (TCP and SSL). To initiate an outgoing TCP or SSL connection to a remote host, send data to the XBee Smart Modem's serial port. If CI (Protocol/Connection Indication) reports a value of 0, then the connection was successfully established, otherwise the value of CI indicates why the connection attempt failed. Any data received over the connection is sent out the XBee Smart Modem's serial port. A connection is closed when: n The remote end closes the connection. No data has been sent or received for longer than the socket timeout set by TM (IP Client Connection Timeout). You make and apply a change to the IP, DL, or DE. Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide 135 Socket behavior Transparent mode behavior for outgoing UDP data Transparent mode behavior for outgoing UDP data To send outgoing UDP data to a remote host, send data to the XBee Smart Modem's serial port. If CI (Protocol/Connection Indication) reports a value of 0, the data was successfully sent; otherwise, the value of CI indicates why the data failed to be sent. The RO (Packetization Timeout) setting provides some control in how the serial data gets packetized before being sent to the remote host. The first send opens up a UDP socket used to send and receive data. Any data received by this socket is sent out the XBee Smart Modem's serial port. Transparent mode behavior for incoming TCP connections The C0 (Source Port) and IP (IP Protocol) settings specify the listening port and protocol used for incoming connections (TCP) and incoming data (UDP) in Transparent mode. SSL is not currently supported for incoming connections. When the IP setting is TCP and there is no existing connection to or from the XBee Smart Modem, the device accepts one incoming connection. Any data received on the connection is sent out the XBee Smart Modem's serial port. Any data sent to the XBee Smart Modem's serial port is sent over the connection. If the connection is disconnected, it discards pending data. Transparent mode behavior for incoming UDP connections When the IP (IP Protocol) setting is UDP any data sent from a remote host to the XBee Smart Modem's network port specified by C0 (Source Port) is sent out the XBee Smart Modem's serial port. Any data sent to the XBee Smart Modem's serial port is sent to the network destination specified by the DL (Destination Address) and DE (Destination Port) settings. If the DL and DE settings are unspecified or invalid, the XBee Smart Modem discards data sent to the serial port. Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide 136 Troubleshooting This section contains troubleshooting steps for the XBee Smart Modem. Cannot find the serial port for the device Correct a macOS Java error Unresponsive cellular component in Bypass mode Not on expected network after APN change Syntax error at line 1 Error Failed to send SMS Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide 138 140 141 142 142 142 137 Troubleshooting Cannot find the serial port for the device Cannot find the serial port for the device Condition In XCTU, the serial port that your device is connected to does not appear. Solution 1. Click the Discover radio modules button 2. Select all of the ports to be scanned. 3. Click Next and then Finish. A dialog notifies you of the devices discovered and their details. 4. Remove the development board from the USB port and view which port name no longer appears in the Discover radio devices list of ports. The port name that no longer appears is the correct port for the development board. Other reasons that the XBee Smart Modem is not discoverable include: Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide 138 Troubleshooting Cannot find the serial port for the device 1. If you accidentally have the loopback pins jumpered. 2. You may not be using an updated FTDI driver. a. This may require you to reboot your computer. b. Disconnect the power and USB from the XBIB-U-DEV board and reconnect it. Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide 139 Troubleshooting Correct a macOS Java error Correct a macOS Java error When you use XCTU on macOS computer, you may encounter a Java error. Condition When opening XCTU for the first time on a macOS computer, you may see the following error: Solution 1. Click More info to open a browser window. 2. Click Download to get the file javaforosx.dmg. 3. Double-click on the downloaded javaforosx.dmg. 4. In the dialog, double-click the JavaForOSX.pkg and follow the instructions to install Java. Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide 140 Troubleshooting Unresponsive cellular component in Bypass mode Unresponsive cellular component in Bypass mode When in Bypass mode, the XBee Smart Modem does not automatically reset or reboot the cellular component if it becomes unresponsive. Condition In Bypass mode, the XBee Smart Modem does not respond to commands. Solution 1. Query the AI (Association Indication) parameter to determine whether the cellular component is connected to the XBee Smart Modem software. If AI is 0x2F, Bypass mode should work. If not, look at the status codes in AI (Association Indication) for guidance. 2. You can send the !R (Modem Reset) command to reset only the cellular component. Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide 141 Troubleshooting Not on expected network after APN change Not on expected network after APN change Condition The XBee Smart Modem is not on the expected network after a change to the AN (Access Point Name) command. Solution Send ATNR0 to reset Internet connectivity. See NR (Network Reset) for more information. Syntax error at line 1 You may get a syntax error at line 1 error after pasting example MicroPython code and pressing Ctrl+D. Solution This commonly happens when you accidentally type a character at the beginning of line 1 before pasting the code. Error Failed to send SMS In MicroPython, you consistently get Error Failed to send SMS messages. Solution Your device cannot connect to the cell network. The reason may be: 1. The antenna is improperly or loosely connected. 2. The device is at a location where cellular service cannot reach. If the device is connected to the network, the red LED blinks about twice in a second. If it is not connected it does not blink; see The Associate LED. 3. You SIM card is out of SMS text quota. 4. The device is not getting enough current, for example if power is being supplied only by USB to the XBIB development board, rather than using an additional external power supply. Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide 142 Regulatory information Modification statement Interference statement FCC Class B digital device notice RF exposure FCC-approved antennas Labeling requirements for the host device Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide 144 144 144 145 145 146 143 Regulatory information Modification statement Modification statement Digi International has not approved any changes or modifications to this device by the user. Any changes or modifications could void the user’s authority to operate the equipment. Digi International n’approuve aucune modification apportée à l’appareil par l’utilisateur, quelle qu’en soit la nature. Tout changement ou modification peuvent annuler le droit d’utilisation de l’appareil par l’utilisateur. Interference statement This device complies with Part 15 of the FCC Rules and Industry Canada license-exempt RSS standard (s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement. FCC Class B digital device notice This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: n Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. IMPORTANT: The RF module has been certified for mobile and base radio applications. If the module will be used for portable applications, the device must undergo SAR testing. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Re-orient or relocate the receiving antenna, Increase the separation between the equipment and receiver, Connect equipment and receiver to outlets on different circuits, or Consult the dealer or an experienced radio/TV technician for help. Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide 144 Regulatory information RF exposure RF exposure CAUTION! This equipment is approved for mobile and base station transmitting devices only. Antenna(s) used for this transmitter must be installed to provide a separation distance of at least 25 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. ATTENTION! Cet équipement est approuvé pour la mobile et la station base dispositifs d'émission seulement. Antenne(s) utilisé pour cet émetteur doit être installé pour fournir une distance de séparation d'au moins 25 cm à partir de toutes les personnes et ne doit pas être situé ou fonctionner en conjonction avec tout autre antenne ou émetteur. FCC-approved antennas The can be installed using antennas and cables constructed with non-standard connectors (RPSMA, RPTNC, and so forth) An adapter cable may be necessary to attach the XBee connector to the antenna connector. The modules are FCC approved for fixed base station and mobile applications for the channels indicated in the tables below. If the antenna is mounted at least 25 cm from nearby persons, the application is considered a mobile application. The antennas below have been approved for use with this module. Digi does not carry all of these antenna variants. Contact Digi Sales for available antennas. Bluetooth antennas The following tables cover the antennas that are approved for use with the Bluetooth radio. Integral antenna Part number Type (description) Gain Application 31000020-01 Integral antenna -2.5 dBi Fixed/Mobile Dipole antennas Part number Type (description) Gain Application A24-HASM-450 Dipole (Half-wave articulated RPSMA-4.5") 2.1 dBi Fixed/Mobile A24-HABUF-P5I Dipole (Half-wave bulkhead mount U.FL w/ 5" pigtail) 2.0 dBi Fixed/Mobile A24-HASM-525 Dipole (Half-wave articulated RPSMA-5.25") 2.0 dBi Fixed/Mobile Flex PCB antennas Part number Type (description) Gain Application FXP74.07.0100A Flexible PCB, U.FL w/ 100mm pigtail 4.0 dBi Fixed/Mobile Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide 145 Regulatory information Labeling requirements for the host device Cellular antennas Antenna gain must be below: Frequency band Gain Band 2 (1900 MHz) 9.70 dBi Band 4 (1700 MHz) 6.00 dBi Band 12 (700 MHz) 9.01 dBi Bande de fréquence Gain Band 2 (1900 MHz) 9.70 dBi Band 4 (1700 MHz) 6.00 dBi Band 12 (700 MHz) 9.01 dBi Labeling requirements for the host device The device shall be properly labeled to identify the product within the host device. The certification labels of the module shall be clearly visible at all times when installed in the host device, otherwise the host device must be labeled to display the FCC ID and IC of the module, preceded by the words "Contains transmitter module", or the word "Contains", or similar wording expressing the same meaning, as follows: Contains FCC ID: MCQ-XB3C1 Contains IC: 1846A-XB3C1 Contains FCC ID:RI7XE866A1NA Contains IC: 5131A-XE866A1NA L'appareil hôte doit être étiqueté comme il faut pour permettre l'identification des modules qui s'y trouvent. L'étiquettes de certification du module donné doit être posée sur l'appareil hôte à un endroit bien en vue en tout temps. En l'absence d'étiquette, l'appareil hôte doit porter une étiquette donnant le FCC ID et le IC du module, précédé des mots « Contient un module d'émission », du mot « Contient » ou d'une formulation similaire exprimant le même sens, comme suit: Contains FCC ID: MCQ-XB3C1 Contains IC: 1846A-XB3C1 Contains FCC ID:RI7XE866A1NA Contains IC: 5131A-XE866A1NA This Class B digital apparatus complies with Canadian ICES-003. Cet appareil numérique de classe B est conforme à la norme canadienne ICES-003. Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide 146

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
Page Count                      : 146
Page Mode                       : UseOutlines
Page Layout                     : SinglePage
Language                        : en-us
Producer                        : madbuild
Create Date                     : 2018:01:12 11:20:23-06:00
Modify Date                     : 2018:01:12 11:20:23-06:00
Title                           : Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide
Author                          : Digi XBee3 Cellular LTE Cat 1 Smart Modem User Guide
Subject                         : Digi XBee3 Cellular LTE Cat 1
Keywords                        : Digi, XBee3, Cellular, LTE, Cat, 1, Embedded, Modem
EXIF Metadata provided by EXIF.tools
FCC ID Filing: MCQ-XB3C1

Navigation menu