Digigram ES8AESV2 Audio Equipment User Manual ES881v2 1241v2 16161v2

Digigram Audio Equipment ES881v2 1241v2 16161v2

Manual

Download: Digigram ES8AESV2 Audio Equipment User Manual ES881v2 1241v2 16161v2
Mirror Download [FCC.gov]Digigram ES8AESV2 Audio Equipment User Manual ES881v2 1241v2 16161v2
Document ID776876
Application ID1Z8n5aqGSTDpyWmRAp3ZLg==
Document DescriptionManual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize154.35kB (1929351 bits)
Date Submitted2007-04-04 00:00:00
Date Available2007-04-05 00:00:00
Creation Date2007-03-13 09:54:36
Producing SoftwareAcrobat Distiller 7.0.5 (Windows)
Document Lastmod2007-03-13 11:02:48
Document TitleES881v2/1241v2/16161v2
Document CreatorAcrobat PDFMaker 7.0.7 pour Word
Document Author: JKR

ES 881V2
ES1241V2
ES16161V2
User’s Manual
Manuel Utilisateur
EtherSound ES881v2, ES1241v2 & ES16161v2
Ethernet Audio Bridges
Important Safety Information
read carefully before using this equipment!
Follow these instructions and keep them in a safe place! Keep in mind that damages due to failure to
observe the instructions contained in this manual are not covered by warranty.
Instructions importantes de sécurité
lire soigneusement avant d'utiliser l'équipement!
Lisez et suivez ces instructions. Conservez les pour consultation ultérieure! Les dommages dus au
non-respect des instructions contenues dans ce manuel ne sont pas couverts par la garantie.
Wichtige Sicherheitshinweise
vor Inbetriebnahme des Gerätes sorgfältig lesen!
Throughout this manual,
the lightning bolt triangle is
used to alert the user to the
risk of electric shock.
The
exclamation
point
triangle is used to alert the
user to important operating
or maintenance instructions.
Befolgen Sie die Anweisungen und bewahren Sie sie für spätere Fragen auf! Bei Schäden, die durch
Nichtbeachten dieser Bedienungsanleitung verursacht werden, erlischt der Garantieanspruch!
Do Not Open the Cabinet
There
are
no
user-serviceable
components inside this product.
Opening the cabinet may present a shock hazard,
and any modification to the product will void
your warranty. If it is necessary to open the device
for maintenance or advanced configuration
purposes, this is to be done by qualified personnel
only after disconnecting the power cord and
network cables!
Power supply
The device is to be connected only to a
power supply as specified in this
manual and marked on the equipment. This
equipment must be earthed!
Do not block any of the ventilation openings!
Humidity
To reduce the risk of fire or shock, do not expose
this device to rain or moisture. Do not place
objects filled with liquid on this device.
Installation Location
To ensure proper operation and to avoid safety
hazards, the device must be installed in a 19“ rack
mount chassis. If this is not possible, place it on a
firm and level surface. Avoid installation in
extremely hot or cold locations, or in an area that
is exposed to direct sunlight or heating
equipment. Avoid moist or humid locations.
Cleaning
Clean only with a soft, dry cloth. If necessary,
after disconnecting the unit’s cables, wipe it with a
soft cloth dampened with mild soapy water, then
with a fresh cloth with clean water. Wipe dry
immediately with a dry cloth. NEVER use
benzene, aerosol cleaners, thinner, alcohol or any
other volatile cleaning agent. Do not use abrasive
cleaners, which may damage the finish of metal or
other parts.
Refer all servicing to qualified service
personnel.
Servicing is required when the apparatus has been
damaged in any way, such as power supply cord
or plug is damaged, liquid has been spilled, the
apparatus has been exposed to rain or moisture,
does not operate normally, or has been dropped.
Moving the device
Before moving the unit, be certain to disconnect
any cables that connect with other components.
Ne pas ouvrir l’appareil
L'ouverture du coffret peut produire
un risque de choc électrique, et toute
modification du produit annule votre garantie. S'il
est nécessaire d'ouvrir l'appareil pour l'entretien
ou la configuration avancée, cela doit être fait par
du personnel qualifié, après avoir débranché le
cordon d'alimentation et les câbles réseaux !
Alimentation
Il est primordial de connecter
l'appareil
à
une
alimentation
électrique telle que spécifiée dans ce
manuel d´utilisateur et sur le matériel même.
Cet équipement doit être raccordé à la terre !
N'obstruer aucune ouverture de ventilation !
Humidité
Afin de réduire les risques de feu ou de choc,
n'exposez pas cet appareil à la pluie ou l'humidité.
Ne placez pas d´objet contenant un liquide sur
l'appareil.
Installation , mise en place
Afin d'assurer le fonctionnement correct et de
minimiser les risques potentiels liés à la sécurité,
l'appareil doit être installé dans une baie de
montage de type 19 pouces. Si cela ne vous est
pas possible, placez le sur une surface solide et
plane.
Evitez une installation dans des endroits très
chauds ou très froids ainsi que dans des lieux
exposés directement au soleil. Evitez les lieux
présentant un excès d'humidité.
Nettoyage
Nettoyez uniquement avec un chiffon doux et sec.
Si nécessaire, après avoir débranché le cordon
d´alimentation, essuyez-le avec un chiffon doux
humidifié avec de l´eau savonneuse puis rincez le
á l´aide d un chiffon propre et d´eau claire.
Séchez-le immédiatement avec un chiffon sec.
N'utilisez JAMAIS d´essence, de nettoyants en
aérosols, d´alcool ou tout autre agent nettoyant
volatile. N'utilisez pas de produits nettoyants
abrasifs qui pourraient endommager les finitions
métalliques ou d´autres pièces.
Réparation
Lorsque l'appareil a été endommagé quelle qu'en
soit la cause ou qu'il ne fonctionne pas
normalement, toute réparation doit être effectuée
par du personnel qualifié. Avant de transporter
l´unité, assurez-vous d´avoir bien déconnecté le
cordon d'alimentation ainsi que tous les câbles la
reliant à d´autres appareils.
Gerät nicht öffnen
Öffnen des Geräts kann eine
Gefährdung durch Stromschlag und
Erlöschen der Garantie zur Folge haben.
Reparaturarbeiten
und
Änderungen
der
Hardwarekonfiguration
dürfen
nur
von
qualifiziertem Personal nach entfernen der Stromund Netzwerkkabel durchgeführt werden.
Stromversorgung
Das Gerät darf nur mit der in dieser
Bedienungsanleitung und auf dem
Gerät angegebenen Stromversorgung
betrieben werden. Erdung ist zu gewährleisten!
Belüftungsschlitze nicht verdecken!
Wasser und Feuchtigkeit
Um Brand- oder Stromschlagrisiken zu
vermeiden, darf das Gerät nicht mit Feuchtigkeit
in Berührung kommen.
Aufbau des Geräts
Um den einwandfreien Betrieb zu gewährleisten
und Sicherheitsrisiken zu vermeiden, muss das
Gerät in einem 19-Zoll Baugruppenrahmen
montiert werden. Nur wenn dies nicht möglich
ist, stellen Sie das Gerät auf einen festen,
waagerechten Untergrund. Meiden Sie Standorten
in
den
Nähe
von
Wärmeoder
Feuchtigkeitsquellen
sowie
direkte
Sonneneinstrahlung.
Reinigen des Geräts
Säubern Sie das Gerät nur mit einem weichen,
trockenen Tuch. Bei Bedarf verwenden Sie ein mit
mildem Seifenwasser befeuchtetes Tuch, nachdem
Sie die Netzanschlusskabel aus der Steckdose
gezogen haben, anschliessend ein weiches, mit
klarem Wasser befeuchtetes Tuch. Trocken Sie
das Gerät sofort im Anschluss. Keinesfalls Benzol,
Verdünner oder sonstige starke Lösungsmittel
oder Scheuerreiniger verwenden, da hierdurch
das Gehäuse beschädigt werden könnte.
Lassen Sie etwaige Reparaturen nur von
qualifizierten Fachleuten durchführen!
Sollten das Netzkabel oder der Netzstecker
beschädigt sein, oder sollte das Gerät selbst
beschädigt worden sein (z. B. durch Eindringen
von Feuchtigkeit durch Fall auf den Boden), oder
sollte es nicht ordnungsgemäss funktionieren oder
eine deutliche Funktionsabweichung aufweisen,
so ist es von qualifizierten Fachleuten zu
reparieren.
EtherSound ES881v2, ES1241v2 & ES16161v2
Ethernet Audio Bridges
TABLE OF CONTENTS
INFORMATION FOR THE USER ............................................................................................................................................................. 3
KEY FEATURES........................................................................................................................................................................................................ 5
OVERVIEW .................................................................................................................................................................................................................... 5
Contents of this package ...........................................................................................................................................................................................5
The ES881v2, ES1241v2, and ES16161v2 front panels.................................................................................................................................6
ES881v2, ES1241v2, and ES16161v2 back panels .........................................................................................................................................7
INSTALLATION ....................................................................................................................................................................................................... 9
Before mounting devices in a rack… .....................................................................................................................................................................9
Internal settings.....................................................................................................................................................................................................9
Connecting your EtherSound device........................................................................................................................................................................9
Power supply..........................................................................................................................................................................................................9
Network ..................................................................................................................................................................................................................9
Example 1: bi-directional point-to-point transmission of eight audio channels............................................................................9
Example 2: more complex architectures................................................................................................................................................9
Synchronization .................................................................................................................................................................................................. 10
Connecting a computer to manage the EtherSound network............................................................................................................... 10
Audio ..................................................................................................................................................................................................................... 10
GPIO...................................................................................................................................................................................................................... 10
Serial port (RS232 on DB9) ........................................................................................................................................................................... 11
Remote set-up by means of configuration software ................................................................................................................................ 11
Firmware update ....................................................................................................................................................................................................... 11
SPECIFICATIONS .................................................................................................................................................................................................12
Configuration .............................................................................................................................................................................................................. 12
Inputs/outputs ............................................................................................................................................................................................................ 12
Connectivity................................................................................................................................................................................................................. 12
Synchronization.......................................................................................................................................................................................................... 12
APPENDIX A: GPIO CONNECTORS .................................................................................................................................................13
General Purpose Inputs (GPIs)............................................................................................................................................................................... 13
GPI #1 .................................................................................................................................................................................................................. 13
GPI #1 .................................................................................................................................................................................................................. 13
GPI #3 & GPI #4 .............................................................................................................................................................................................. 13
GPI optocoupler specifications ....................................................................................................................................................................... 14
General Purpose Outputs (GPOs)......................................................................................................................................................................... 14
GPO relay specifications................................................................................................................................................................................... 14
APPENDIX B: SETTING THE INTERNAL JUMPER ............................................................................................................15
Jumper location on the main board ..................................................................................................................................................................... 15
Select sampling frequency............................................................................................................................................................................... 16
APPENDIX C: ES16161V2 WIRING OF THE DIGITAL INPUTS AND OUTPUTS ..................................17
The double Sub-D connectors................................................................................................................................................................................ 17
Default pinout ............................................................................................................................................................................................................ 17
Default I/O assignment.................................................................................................................................................................................... 18
Modify I/O group assignment ................................................................................................................................................................................ 18
Distribution of the signals ....................................................................................................................................................................................... 18
Connector localization on motherboard and connector board ............................................................................................................. 18
Ribbon cables linking motherboard and connector board...................................................................................................................... 19
Signals................................................................................................................................................................................................................... 19
Signal routing towards the external connectors ........................................................................................................................................ 19
APPENDIX D: GLOSSARY ..........................................................................................................................................................................20
EtherSound ES881v2, ES1241v2 & ES16161v2
Ethernet Audio Bridges
INFORMATION FOR THE USER
This equipment has been tested and found to comply with the limits for a CLASS B digital device, pursuant to Part 15 of the FCC
Rules and with the following European and international Standards for:
Electrical safety:
Electromagnetic Compatibility:
Europe : EN60950, 3rd edition
European Directive 73/23/CEE “Low Voltage Directive“
International: IEC 60950, 3rd edition
Europe: EN55022:1998 + A1:2000, Class B / EN55024 : 1998 + A1:2001
European Directive 89/336/CEE on electromagnetic compatibility
International: CISPR22:1997 + A1:2000 CLASS B
United states: FCC rules-Part 15 Class B ( digital device )
In order to guarantee compliance with the above standards in an installation, the following must be done:
the provided cables must not be modified.
·
·
additional cables used must have their respective shield connected to each extremity.
The limits specified in the standards are designed to provide reasonable protection against harmful interference in a residential
installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with
the instruction, may cause harmful interference to radio communications. However, there is no guarantee that interference will not
occur in a particular installation.
If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment
off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
* reorient or relocate the receiving antenna.
* increase the separation between the equipment and the receiver.
* connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
* consult the dealer or an experienced audio/television technician for help.
Note:
Connecting this device to peripheral devices that do not comply with CLASS B requirements or using an unshielded peripheral data
cable could also result in harmful interference to radio or television reception. The user is cautioned that any changes or modifications
not expressly approved by the party responsible for compliance could void the user’s authority to operate this equipment. To ensure
that the use of this product does not contribute to interference, it is necessary to use shielded I/O cables.
French version / version française p. 22
Copyright 2007 Digigram. All rights reserved.
No portion of this manual may be reproduced without prior written consent from Digigram. The copyright protection claimed here includes
photocopying, translation and/or reformatting of the information contained in this manual.
While every effort has been made to ensure accuracy, Digigram is not responsible for errors and omissions, and reserves the right to make improvements
or changes in the products and programs described without notice.
Digigram, EtherSound, ES881v2, ES1241v2, and ES16161v2 are registered trademarks or trademarks of Digigram S.A.. All other trademarks are property of
their respective holders.
D
You have just acquired a Digigram EtherSound audio bridge
and we congratulate you!
Digigram EtherSound ES881v2 / ES1241v2 / ES16161v2 are equipped with AES/EBU interfaces including
hardware sample rate converters (SRC). They allow the realization of flexible and powerful EtherSound
networks.
The manual at hand will guide through installation and operation. For any software related issue, please
refer to the specific documentation provided in its on-line help.
For more information on EtherSound networks and wiring recommendations please consult the document
‘Creating EtherSound Networks’ (English), available on the enclosed CD-ROM or on our web site.
KEY FEATURES
ES881v2:
• 4 AES/EBU digital stereo inputs with hardware sample rate converters, inserted into 8 EtherSound channels
• 4 AES/EBU digital stereo outputs, extracted from 8 EtherSound channels
ES1241v2:
• 2 AES/EBU digital stereo inputs with hardware sample rate converters, inserted into 4 EtherSound channels
• 6 AES/EBU digital stereo outputs, extracted from 12 EtherSound channels
ES16161v2:
•
•
•
•
•
•
•
•
8 AES/EBU digital stereo inputs with hardware sample rate converters, inserted into 16 EtherSound channels
8 AES/EBU digital stereo outputs, extracted from 16 EtherSound channels
1 Word Clock input
1 Word Clock output
1 RJ45 port for control and management
19“ 1 RU enclosure
Remote control and management via ‘EScontrol’ software
XLR connectors
(ES16161v2: 4 Sub-D 25-pin connectors)
OVERVIEW
Contents of this package
The package consists of the following components:
•
•
•
•
•
one ES881v2, ES1241v2 or ES16161v2 1U 19 inch rack device
a power cord
counterparts for the GPIO terminal blocks
the User’s Manual at hand
a CD-Rom with configuration and control software
EtherSound ES881v2, ES1241v2 & ES16161v2
Ethernet Audio Bridges
The ES881v2, ES1241v2, and ES16161v2 front panels
1. Device status group (two yellow LEDs):
ES CLOCK
The first LED is called “ES CLOCK”. It shines when the device is the ‘Clock Source’ of the EtherSound
network and provides the clock for the entire network (see document on EtherSound for more details on
the ‘Clock Source’ concept)
EXT SYNC
The second diode is called “EXT SYNC”, indicating that the device synchronizes its clock on an external
one.
2. Network status group
These four green diodes light up when the devices are connected to the EtherSound network; as soon as a
network activity is detected, they start to flash indicating an activity on the two Ethernet ports (“IN” and
“OUT”); RX flashing means that data are received while TX flashing means that data are transmitted.
3. Power
This LED simply shows that the device is up and running!
D
ES881v2, ES1241v2, and ES16161v2 back panels
1. Audio connectors
On ES881v2, four male XLR-3 connectors are used to output eight EtherSound channels on four AES/EBU
stereo outputs, four female XLR-3 connectors to input four AES/EBU stereo inputs onto eight EtherSound
channels.
On ES1241v2, six male XLR-3 connectors are used to output twelve EtherSound channels on six stereo
AES/EBU stereo outputs, two female XLR-3 connectors to input two AES/EBU stereo inputs onto four
EtherSound channels.
On ES16161v2, two female Sub-D 25-pin connectors are used to output sixteen EtherSound channels on
eight stereo AES/EBU stereo outputs, two female Sub-D 25-pin connectors to input eight AES/EBU stereo
inputs onto sixteen EtherSound channels.
2. Network connectors
These two NeutrikTM EtherConTM RJ45 connectors allow of a steady and reliable connection to the EtherSound
network. The “IN” port receives the descending EtherSound stream (‘downstream’, coming from the ‘Clock
Source’) while the “OUT” port receives the ascending EtherSound stream (‘upstream’) and transmits it to the
“IN” port; for more details on the concepts of ‘upstream’ and ‘downstream’ please refer to the document
‘EtherSound Overview’, available on the enclosed CD-ROM and on our web site.
EtherSound ES881v2, ES1241v2 & ES16161v2
Ethernet Audio Bridges
3. GPIO connectors
These terminal blocks allow setup of external control and monitoring devices through configurable and
protected General Purpose Inputs and Outputs. See dedicated GPIO chapter for details.
Note: the GPIO port is managed by configuration software only.
4. Serial port
RS232 interface on DB9.
Note: The RS232 serial port management requires specific software.
5. Word clock synchronization
Two female BNC connectors, ‘Word Clock In’ and ‘Word Clock Out’, allow synchronization with an
external clock. For more details see the corresponding chapter.
6. RJ45 ES control port
This port allows remote control and management of your network via an EtherSound management
software such as EScontrol.
7. Ground
Connect this ground bolt to the chassis of the mounting rack for a better grounding of the electronics, thus
ensuring immunity to electromagnetic interference.
8. Power supply
Power plug MUST be earthed properly.
D
INSTALLATION
Before mounting devices in a rack…
Internal settings
On ES881v2, ES1241v2, and ES16161v2 the local sampling frequency is switchable by means of a jumper
between 44.1 kHz and 48 kHz.
Preset default value is 48 kHz.
In case you need to change the default setting, please refer to appendix B of this manual.
Note: These operations require opening of the cabinet and shall be done by qualified personnel only.
Connecting your EtherSound device
It is recommended to establish all connections before powering up the device.
Power supply
Before plugging the power cord, make sure that:
• the power cord is not damaged
• the AC outlet used is properly earthed.
Just like for any other audio system, power the individual devices up following the audio path and power
down in the opposite direction.
Do not allow anything to rest on the power cable. Keep the power cable away from where people could trip
over it.
Network
The cable type most commonly used today is CAT5e. For more detailed information, please refer to the
document “Building ES Networks”, available on the enclosed CD-ROM and on our web site.
TM
TM
The network connections are established via two Neutrik EtherCon RJ45
receptacles. Connection is very easy: use the connector labeled “IN” to connect the
descending EtherSound stream (downstream, coming from the ‘Clock Source’), the
connector labeled “OUT” to connect the ascending EtherSound stream (‘upstream’).
TM
TM
The Neutrik EtherCon RJ45 provide secure connection through a latching
system. To disconnect the cable from the device, press the latch, then withdraw the
cable while maintaining the latch pushed.
Example 1: bi-directional point-to-point transmission of eight audio channels
This application is very easy with EtherSound ES881v2, ES1241v2, and ES16161v2.
Connect a standard Ethernet cable between the “OUT” port of the first Ethernet bridge to the “IN” port of the
second Ethernet bridge. Bring into line the EtherSound channels on the two devices (see the on-line help of
the configuration software).
Example 2: more complex architectures
System topology may be daisy chain, star, ring, or a combination of star and daisy chain. By default, the first
device in a network, such as an EtherSound ES881v2, provides the master clock for the entire network. This
device is called ‘Clock Source’. Note that in a ring configuration you must configure a device as Clock Source
(this is done by software, the device is then called ‘Preferred Clock Source’). Nevertheless, you have the
possibility to synchronize the ‘Clock Source’ device on an external clock by using the ‘Word Clock In’ input
and by then providing this clock to the EtherSound bridges downstream from the ‘Clock Source’ passing
through the ‘Word Clock Out’ outputs.
Connect the “OUT” port with the “IN” port of the following EtherSound device.
Repeat this step for each device in the network. The maximum distance between two devices is 100 meters
(≈330 feet). Intermediate switches or fiber optic links may be used to considerably increase this distance.
EtherSound ES881v2, ES1241v2 & ES16161v2
Ethernet Audio Bridges
Synchronization
ES881v2, ES1241v2, and ES16161v2 support several synchronization modes.
Synchronization via:
• the network (except in ‘Clock Source’ mode)
• the ‘AES In 1’ input
• the Word clock input
If the equipment is the Clock Source, it provides the clock for the network. It can be synchronized on the
internal clock, on the signal connected to the “AES In 1”, or on the signal connected to the Word Clock input.
In the last case, make sure to activate a frequency conversion stage (SRC) from the configuration software, if
the AES/EBU input signals are not synchronized on the Word Clock. Likewise, enabling the SRC is obligatory
in the case of synchronization on the internal clock.
When the device is not in ‘Clock Source’ mode, it is synchronized on the signal coming from the network:
•
the ‘Word Clock Out’ output allows synchronizing the devices connected on the ‘AES In 1’ inputs. In
this case it is not necessary to insert an SRC stage.
• If the devices connected to the AES/EBU inputs are not synchronized on the network, sample rate
conversion (SRC) is required.
Use the configuration software provided to set these parameters.
Connecting a computer to manage the EtherSound network
To connect a PC directly to an ES881v2, ES1241v2, or ES16161v2, it must be equipped with a network card.
Use an Ethernet cable to connect the network card to the RJ45 ‘Ethernet’ port of the Clock Source device.
You can as well access the Clock Source through a regular Ethernet network via the device’s RJ45 Ethernet
control port.
Audio
The pinout used on the XLRs is standard: pin 1 carries the signal ground, pin 2 carries the positive signal
(“hot”, +) and pin 3 carries the negative signal (“cold”, -).
GPIO
ES881v2, ES1241v2, and ES16161v2 are shipped with four GPIs and four GPOs on terminal blocks,
counterparts are supplied. For details see Appendix A.
D
Serial port (RS232 on DB9)
Pin # Description
not connected
RxD (received data)
TxD (transmitted data)
not connected
signal ground
not connected
RTS (request to send)
CTS (clear to send)
not connected
ES881v2, ES1241v2, and ES16161v2 dispose of a serial RS232 male port on the rear panel. Use this port to
connect any compatible device. For pinout allocation details, please refer to the figure and table above.
Note: The RS232 serial port management requires specific software.
Remote set-up by means of configuration software
Use of the configuration software allows for the management of all devices on the EtherSound network; for
software details, please refer to the on-line help file.
ES881v2, ES1241v2, and ES16161v2 are shipped with a CD-ROM containing the EtherSound driver and the
Digigram configuration software, EScontrol. To install this software, please refer to the CD-ROM delivered
with your EtherSound device.
ES881v2, ES1241v2, and ES16161v2 may also be managed through configuration software edited by
Digigram development partners.
To uninstall the software go to Add/Remove programs in the Windows Control Panel.
Firmware update
Digigram may decide to publish firmware updates. It may then become necessary to upgrade your devices. In
this case please refer to the respective documentation provided with the firmware upgrade tool.
10
EtherSound ES881v2, ES1241v2 & ES16161v2
Ethernet Audio Bridges
SPECIFICATIONS
Configuration
Size
1U 19” rack : 43.9 x 482.6 x 297.1 mm
Power supply
100 - 240 VAC, 47-63 Hz
switching-mode, automatic voltage detection
W ARNING: Do not open the power supply module. It contains hazardous
voltages.
There are no user-serviceable parts inside
Temp / humidity
(non-condensing)
Operating:
Storage:
Power consumption
at 240 V
at 100 V
0°C - 50°C / 0% - 95%
-5°C – 70°C / 0% - 95%
ES881v2:
0.06 A
0.12 A
ES1241v2:
0.06 A
0.12 A
ES16161v2:
0.07 A
0.14 A
∼3,1 kg (∼6.85 lbs)
Net weight
Inputs/outputs
EtherSound ES881v2 EtherSound ES1241v2 EtherSound ES16161v2
Digital audio
AES/EBU 3
4 stereo inputs
4 stereo outputs
2 stereo inputs
6 stereo outputs
8 stereo inputs
8 stereo outputs
With one hw sample rate converter per input,
conversion ratio 1:3 to 3:1, up to 96 kHz
110 Ω
Impedance
Sampling frequencies
available
48 kHz or 44.1 kHz
Frequency response
at 44.1 kHz
at 48 kHz
10 Hz-21 kHz +/- 0,1 dB
10 Hz-23 kHz +/- 0,1 dB
Connectivity
EtherSound ES881v2 EtherSound ES1241v2 EtherSound ES16161v2
Digital audio
EtherSound
Control
GPIO
Serial ports
4 female XLR-3 and
4 male XLR-3
2 female XLR-3 and
6 male XLR-3
4 female Sub-D 25
2 female EtherCon RJ45 compatible (connections “IN”/“OUT”)
1 RJ45
4 optocoupled inputs and 4 relay outputs on 8-point terminal blocks
1 RS232 on DB9
Synchronization
Clock source
If ‘Clock Source’ in an EtherSound network:
Internal, Word Clock or on ‘AES IN 1’ input
If not ‘Clock Source’: EtherSound network, Word Clock or on ‘AES IN 1’ input
(synchronized on the ‘Clock Source’ clock)
11
D
APPENDIX A: GPIO CONNECTORS
ES881v2, ES1241v2, and ES16161v2 feature four optocoupled GPIs and four relay GPOs.
GPIs allow sending commands to the EtherSound configuration software, GPOs can be
used by the EtherSound configuration software for remote control of external devices.
The GPIO pins are labeled 1 through 8 on the rear panel as illustrated.
General Purpose Inputs (GPIs)
Schematic diagrams show the particular design for each GPI. The GPI status can be either “1” or “0”. It is read
“0” as soon as the system connected to the GPI creates the current labeled “i” on the scheme. Otherwise it is
read “1”. Different GPI designs allow for multiple ways to establish this current, thus offering utmost flexibility
in system configuration to best meet your needs.
Note: Pin 2 delivering +5 V electric potential and pin 4 being connected to ground may also be used in the
configuration of other GPIs.
GPI #1
GPI #1 uses pins 1 & 2
Pin 2 delivers +5 V electric potential. This pin may serve as a source to create a
current flow for GPI #3 and GPI #4.
Switching the GPI state to 0:
Pin 1 is to be connected to ground to establish the “i” current, typically by
connecting it to pin 4.
GPI #1
GPI #3 uses pins 1 & 4
Switching the GPI state to 0:
Pin 3 is to be connected to ground to establish the “i” current, typically by
connecting it to pin 4.
GPI #3 & GPI #4
GPI #3 uses pins 5 & 6, GPI #4 uses pins 7 & 8.
Switching the GPI state to 0:
A current flow is to be established from pin 6 to pin 5 (GPI #3) or from pin 8 to
pin 7 (GPI #4).
GPI optocoupler specifications
12
EtherSound ES881v2, ES1241v2 & ES16161v2
Ethernet Audio Bridges
minimum
current i min to switch GPI
0,5 mA
Maximum current i max supported
50 mA
i calculation rule (GPi #3 & #4)
i (mA) = Vin - 1,2
3,3
Maximum voltage V in supported
50 Vdc
Maximum reverse voltage V in supported
6V
General Purpose Outputs (GPOs)
The ES8 GPOs are relay outputs. They feature two pins each and are all configured the same way. Pins 1 & 2
belong to GPO #1, 3 & 4 to GPO #2, 5 & 6 to GPO #3, and 7 & 8 to GPO #4.
It responds to commands of configuration and management software sent via the Clock Source. If written at
“1”, the GPO closes the linked open collector. If written at “0”, the GPO opens the linked open collector.
GPO relay specifications
Maximum power switching capability
10 W
Maximum switching current
500 mAdc
Maximum carrying current
1 Adc
Maximum switching voltage
100 Vdc
Typical life expectancy (switching max power)
10 operations
13
D
APPENDIX B: SETTING THE INTERNAL JUMPER
These settings shall be executed by qualified personnel only!
Tools required:
•
•
•
a #1 Pozidriv screwdriver
an ESD-preventive wrist strap
a small flat blade screwdriver
Electrostatic discharge (ESD) can damage several components on the board. To avoid such damage in
handling the board, take the following precautions:
Bring the device and everything that contacts it to ground potential by providing a conductive surface and
discharge paths. As a minimum, observe these precautions:
• Disconnect all power and signal sources.
• Place the device on a grounded conductive work surface.
• Ground yourself via a grounding wrist strap or by holding a grounded object.
• Ground any tools that will contact the device.
• Unscrew the eight flat-head Pozidriv screws (four on top-side,
four on bottom-side) counterclockwise and open the cabinet.
Jumper location on the main board
Back panel
Front panel
14
EtherSound ES881v2, ES1241v2 & ES16161v2
Ethernet Audio Bridges
Select sampling frequency
This jumper allows for modification of the ES881v2, ES1241v2, and ES16161v2 sampling frequency. The
default value is preset to 48 kHz. It can be set to 44.1 kHz. Note that this setting is effective only if the device
is the Clock Source of the EtherSound network. In all other cases the sampling frequency is determined by the
incoming EtherSound stream (synchronized on the Clock Source clock). Modifications on devices other than
the Clock Source will be ignored.
15
D
APPENDIX C: ES16161V2
WIRING OF THE DIGITAL INPUTS AND OUTPUTS
The double Sub-D connectors
The audio signals on the inputs and outputs are available on the 25-pin Sub-D connectors on the back panel
of the device. Every connector is composed of two banks, each of those receiving four digital AES/EBU stereo
input or output signals. The ‘hot’ signals (+) are located on the upper pins of the Sub-D, the ‘cold’ signals (-)
on the lower pins. The diagram and the tables underneath show the default wiring:
Default pinout
Port 1
Pin #
10
11
12
13
Signal
Port 2
Pin #
AES/EBU IN 1+
AES/EBU IN 2+
AES/EBU IN 3+
AES/EBU IN 4+
NC
NC
NC
NC
NC
GND
NC
NC
NC
14
15
16
17
18
19
20
21
22
23
24
25
Signal
AES/EBU IN 1AES/EBU IN 2AES/EBU IN 3AES/EBU IN 4NC
NC
NC
NC
GND
NC
GND
GND
NC
Pin #
10
11
12
13
Signal
NC
NC
NC
NC
NC
GND
NC
NC
NC
Port 3
Pin #
10
11
12
13
16
Signal
Pin #
AES/EBU OUT 1+
AES/EBU OUT 2+
AES/EBU OUT 3+
AES/EBU OUT 4+
14
15
16
17
18
19
20
21
22
23
24
25
NC
NC
NC
NC
NC
GND
NC
NC
NC
Pin #
AES/EBU IN 5+
AES/EBU IN 6+
AES/EBU IN 7+
AES/EBU IN 8+
14
15
16
17
18
19
20
21
22
23
24
25
Signal
AES/EBU IN 5AES/EBU IN 6AES/EBU IN 7AES/EBU IN 8NC
NC
NC
NC
GND
NC
GND
GND
NC
Port 4
Signal
NC
NC
NC
NC
AES/EBU OUT 1AES/EBU OUT 2AES/EBU OUT 3AES/EBU OUT 4GND
NC
GND
GND
NC
Pin #
10
11
12
13
Signal
Pin #
AES/EBU OUT 5+
AES/EBU OUT 6+
AES/EBU OUT 7+
AES/EBU OUT 8+
14
15
16
17
18
19
20
21
22
23
24
25
NC
NC
NC
NC
NC
GND
NC
NC
NC
Signal
NC
NC
NC
NC
AES/EBU OUT 5AES/EBU OUT 6AES/EBU OUT 7AES/EBU OUT 8GND
NC
GND
GND
NC
EtherSound ES881v2, ES1241v2 & ES16161v2
Ethernet Audio Bridges
Default I/O assignment
Digital AES/EBU stereo inputs
Inputs 1 to 4
Inputs 5 to 8
Outputs 1 to 4
Outputs 5 to 8
Port
Port 1 Bank A
Port 2 Bank A
Port 3 Bank B
Port 4 Bank B
Modify I/O group assignment
Distribution of the signals
Within each group of four AES/EBU stereo inputs or outputs the signals are allotted as follows:
Digital AES/EBU
Bank A
Bank B
stereo I/Os
+ signal
- signal
+ signal
- signal
Inputs/outputs 1 or 5
14
18
Inputs/outputs 2 or 6
15
19
Inputs/outputs 3 or 7
16
20
Inputs/outputs 4 or 8
17
21
Ground
10, 22, 24, 25
Connector localization on motherboard and connector board
17
D
Ribbon cables linking motherboard and connector board
The diagram shows the default configuration
Signals
Digital AES/EBU stereo inputs
Inputs 1 to 4
Inputs 5 to 8
Outputs 1 to 4
Outputs 5 to 8
Port
J11
J4
J71
J10
on connector board
on motherboard
on connector board
on motherboard
To change the assignment of any group of four inputs or four outputs, just reposition the ribbon cables of the
HE connectors on the connector board.
Signal routing towards the external connectors
Internal connector (connector board) External Sub-D 25 Connector
J1R
Port 1 Bank A
J1L
Port 1 Bank B
J2R
Port 2 Bank A
J2L
Port 2 Bank B
J3R
Port 3 Bank A
J3L
Port 3 Bank B
J4R
Port 4 Bank A
J4L
Port 4 Bank B
18
EtherSound ES881v2, ES1241v2 & ES16161v2
Ethernet Audio Bridges
APPENDIX D: GLOSSARY
AUDIO CHANNEL
An audio channel is a single mono audio signal. By extension, an audio channel is one of the 64 slots of an
EtherSound frame, i.e. a signal sampled at 48 kHz or 44.1 kHz with a 24-bit resolution.
CLOCK SOURCE
The first EtherSound device in the network is called the Clock Source. As well as being a source of audio for
the network, the Clock Source provides the commands and the clock for audio channel synchronization.
The Clock Source may also serve as the link between the EtherSound network and configuration software
running on an external computer, connected to its Ethernet IN port.
DAISY CHAIN
The daisy chain is a network topology where all devices are linked “serially”.
Clock
Source
GPIO
General Purpose Inputs Outputs. Each ES8 device has four GPIs and four GPOs. GPOs can be fully
configured to remotely control external devices. GPIs can be used to receive commands from external devices.
19
D
RING
A ring topology may be opted for to benefit from the redundancy that this architecture provides and thus to
further increase reliability. This topology is to be considered an extension of the daisy-chain topology, where
the last device is physically connected back to the first.
The ‘Preferred Clock Source’ is designated by the network administrator.
Preferred Clock
Source
•
In case of a cable failure, the first device after this failure automatically switches to Clock Source
operation. The network remains completely functional, there is no audio channel loss.
•
In case of a device failure, the same recovery mechanism applies, but - obviously - audio connected to
the failing device is missing.
STAR
Star is a network topology where all devices are connected to a same unit (a switch in the following picture)
that is handling all the communications.
Clock
Source
Switch 1
Switch 2
SWITCH
Device to connect two segments of a Local Area Network. Seeking greater filtering and forwarding speeds,
efforts were made to decrease the amount of time required to determine if a packet should be filtered or
forwarded (’latency’) by only examining the address information contained at the start of the Ethernet frame.
The term ‘Ethernet Switch’ now is used for multiple-port-devices, which are able to filter and forward packets
at nearly the speed of Ethernet (‘wire speed’) regardless of the technique.
20
EtherSound ES881v2, ES1241v2 & ES16161v2
Ethernet Audio Bridges
Your notes:
21
EtherSound ES881v2, ES1241v2 & ES16161v2
Passerelles Audio Ethernet
TABLE DES MATIERES
INFORMATION IMPORTANTE..............................................................................................................................................................23
CARACTERISTIQUES PRINCIPALES ................................................................................................................................................24
PRESENTATION ...................................................................................................................................................................................................24
Contenu........................................................................................................................................................................................................................ 24
Faces avant d’ES881v2 et d’ES1241v2 ............................................................................................................................................................. 25
Faces arrière d'ES881v2, ES1241v2et ES16161v2 ....................................................................................................................................... 26
INSTALLATION .....................................................................................................................................................................................................28
Avant de monter les appareils dans une baie................................................................................................................................................... 28
Paramétrages internes ..................................................................................................................................................................................... 28
Connexion de votre rack EtherSound.................................................................................................................................................................. 28
Alimentation ........................................................................................................................................................................................................ 28
Réseau .................................................................................................................................................................................................................. 28
Exemple 1 : transmission point à point bi-directionnelle de huit canaux audio ....................................................................... 28
Exemple 2 : architectures plus complexes.......................................................................................................................................... 28
Synchronisation................................................................................................................................................................................................... 29
Connexion d’un ordinateur pour la gestion d’un réseau EtherSound.................................................................................................. 29
Audio ..................................................................................................................................................................................................................... 29
GPIO (entrées/sorties Tout Ou Rien)............................................................................................................................................................ 29
Port série (RS232 sur DB9)............................................................................................................................................................................ 30
Réglage à distance au moyen du logiciel de configuration..................................................................................................................... 30
Mise à jour du micrologiciel.................................................................................................................................................................................... 30
SPECIFICATIONS .................................................................................................................................................................................................31
Configuration .............................................................................................................................................................................................................. 31
Entrées/sorties............................................................................................................................................................................................................ 31
Connectivité................................................................................................................................................................................................................. 31
Synchronisation .......................................................................................................................................................................................................... 31
ANNEXE A : CONNECTEURS GPIO (TOUT OU RIEN) ..................................................................................................32
General Purpose Inputs (GPIs)............................................................................................................................................................................... 32
GPI n°1................................................................................................................................................................................................................. 32
GPI n°2................................................................................................................................................................................................................. 32
GPIs n°3 & n°4.................................................................................................................................................................................................. 32
Caractéristiques des optocoupleurs des GPIs............................................................................................................................................. 33
General Purpose Outputs (GPOs)......................................................................................................................................................................... 33
Caractéristiques des relais des GPOs........................................................................................................................................................... 33
ANNEXE B : PARAMETRAGE DES CAVALIERS INTERNES ....................................................................................34
Localisation des cavaliers sur la carte principale.............................................................................................................................................. 34
Fréquence d’échantillonnage .......................................................................................................................................................................... 35
ANNEXE C : ES16161V2 CABLAGE DES ENTREES ET SORTIES NUMERIQUES..................................36
Les double-connecteurs Sub-D............................................................................................................................................................................... 36
Brochage par défaut................................................................................................................................................................................................. 36
Assignation des E/S par défaut...................................................................................................................................................................... 37
Changer l'assignation des groupes d’E/S ............................................................................................................................................................ 37
Répartition des signaux ........................................................................................................................................................................................... 37
Localisation des connecteurs sur la carte mère et la carte connecteurs............................................................................................ 37
Nappes de connexion entre carte mère et carte connecteurs.............................................................................................................. 38
Signaux ................................................................................................................................................................................................................. 38
Transfert des signaux vers les connecteurs externes............................................................................................................................... 38
ANNEXE D : GLOSSAIRE .............................................................................................................................................................................39
22
EtherSound ES881v2, ES1241v2 & ES16161v2
Passerelles Audio Ethernet
INFORMATION IMPORTANTE
Cet appareil a été testé et est conforme aux normes suivantes :
Sécurité électrique:
Compatibilité électromagnétique:
Europe : EN60950, 3rd edition
European Directive 73/23/CEE “Low Voltage Directive”
International: IEC 60950, 3rd edition
Europe: EN55022:1998 + A1:2000, Class B / EN55024 : 1998 + A1:2001
European Directive 89/336/CEE on electromagnetic compatibility
International: CISPR22:1997 + A1:2000 CLASS B
United states: FCC rules-Part 15 Class B
Pour assurer une conformité aux standards énumérés ci-dessus, les règles suivantes doivent être observées :
- les câbles utilisés doivent avoir leur blindage respectif relié à chaque extrémité.
Copyright 2005 Digigram. Tous droits réservés.
Aucune partie de ce manuel ne peut être reproduite sans l’accord préalable de Digigram. Cette réserve inclut la photocopie, la traduction et/ou la remise
en forme de l’information contenue dans ce manuel.
Digigram ne peut être tenu responsable pour toute erreur ou omission et se réserve le droit d’apporter des modifications et des améliorations sans
préavis.
Digigram and the Digigram logo, EtherSound, ES881v2, ES1241v2 et ES16161v2 sont des marques déposées ou des marques commerciales de Digigram
S.A.. Toutes les autres marques sont la propriété des sociétés respectives.
La technologie EtherSound est protégée par des brevets et des demandes de brevets internationaux, y compris, mais pas limitée à :
WO 03/023759, FR 2 829 655, USA 2003/0050989
23
D
Vous venez d’acquérir une passerelle audio Digigram EtherSound et nous
vous en félicitons !
Digigram EtherSound ES881v2 / ES1241v2 / ES16161v2 sont équipés d’interfaces AES/EBU avec
convertisseur de fréquences matériels (SRC). Ils permettent la réalisation de réseaux EtherSound souples et
puissants.
Le manuel présent vous guidera dans les étapes d’installation et de l’opération. Pour tout aspect lié au
logiciel, veuillez vous rapporter à la documentation spécifique fournie dans son aide en ligne.
Pour plus d’information sur les réseaux EtherSound et les conseils de câblage, veuillez consulter le document
‘Creating EtherSound Networks’ (anglais), disponible sur le CD-ROM ou sur notre site web.
CARACTERISTIQUES PRINCIPALES
ES881v2 :
•
4 entrées AES/EBU stéréo numériques avec convertisseurs matériels de fréquence d’échantillonnage
(8 canaux EtherSound)
• 4 sorties AES/EBU stéréo numériques (8 canaux EtherSound)
ES1241v2 :
•
2 entrées AES/EBU stéréo numériques avec convertisseurs matériels de fréquence d’échantillonnage
(4 canaux EtherSound)
• 6 sorties AES/EBU stéréo numériques (12 canaux EtherSound)
ES16161v2 :
•
•
•
•
•
•
•
•
8 entrées AES/EBU stéréo numériques avec convertisseurs matériels de fréquence d’échantillonnage
(16 canaux EtherSound)
8 sorties AES/EBU stéréo numériques (16 canaux EtherSound)
1 entrée Word Clock
1 sortie Word Clock
1 port RJ45
Boîtier 19“ 1 RU
Gestion à distance par logiciel ‘ESControl’
Connecteurs XLR (ES16161v2 : 4 Sub-D 25)
PRESENTATION
Contenu
Dans l’emballage vous disposez:
•
•
•
•
•
24
d’un appareil ES881v2, ES1241v2 ou ES16161v2 au format rack 1U 19 pouces
d’un cordon d’alimentation
de contre-fiches pour borniers GPIO
de ce manuel d’utilisateur
d’un CDROM qui contient le logiciel de configuration et de gestion
EtherSound ES881v2, ES1241v2 & ES16161v2
Passerelles Audio Ethernet
Faces avant d’ES881v2 et d’ES1241v2
1. Statut de l’appareil (deux diodes électroluminescentes jaunes):
ES CLOCK
La première diode s’appelle “ ES CLOCK”. Elle s’allume quand l’appareil est la ‘Source d’Horloge’ du réseau
EtherSound et qu’il fournit l’horloge pour tout le réseau EtherSound (voir le document sur EtherSound,
disponible en anglais sur notre site web, pour plus de détails sur le concept de ‘Source d’Horloge’).
EXT SYNC
La deuxième diode s’appelle “ EXT SYNC”, elle indique que l’horloge de l’appareil est synchronisée sur une
horloge externe.
2. Activité réseau
Ces quatre diodes vertes s’allument quand les appareils sont branchés au réseau EtherSound; dès qu’une
activité réseau est constatée, elles se mettent à clignoter indiquant une activité sur les deux ports Ethernet
(“IN” et “OUT”); RX clignotant signale que des données sont reçues tandis que TX clignotant signale que
des données sont transmises.
3.
Alimentation
Cette diode montre simplement que l’appareil est en service !
25
D
Faces arrière d'ES881v2, ES1241v2et ES16161v2
1. Connecteurs audio
Sur ES881v2, quatre connecteurs XLR-3 mâles sont utilisés pour restituer huit canaux EtherSound sur
quatre sorties stéréo au format AES/EBU, quatre connecteurs XLR-3 femelles pour insérer huit canaux
EtherSound sur quatre entrées au format AES/EBU.
Sur ES1241v2, six connecteurs XLR-3 mâles sont utilisés pour restituer douze canaux EtherSound sur six
sorties stéréo au format AES/EBU, deux connecteurs XLR-3 femelles pour insérer quatre canaux
EtherSound sur deux entrées au format AES/EBU.
Sur ES16161v2, deux connecteurs Sub-D 25 femelles sont utilisés pour restituer seize canaux EtherSound
sur huit sorties stéréo au format AES/EBU, deux connecteurs Sub-D 25 femelles pour insérer seize canaux
EtherSound sur huit entrées au format AES/EBU
2. Connecteurs réseau
TM
TM
Ces deux connecteurs Neutrik EtherCon RJ45 permettent un raccordement fiable au réseau
EtherSound. Le port “IN” reçoit le flux EtherSound “downstream” tandis que le port “OUT” reçoit le flux
EtherSound “upstream” pour le transférer au port “IN”; voir le document ’EtherSound Overview’ (disponible
en anglais uniquement) pour plus de détails sur les concepts d’amont (“upstream”) et d’aval
(“downstream”).
26
EtherSound ES881v2, ES1241v2 & ES16161v2
Passerelles Audio Ethernet
3. Connecteurs GPIO (Tout Ou Rien)
Ces borniers permettent l’installation de dispositifs externes de contrôle par des entrées/sorties Tout Ou
Rien configurables et protégées. Voir le chapitre consacré aux entrées/sorties Tout Ou Rien pour plus de
détails.
Note : les ports Tout Ou Rien sont utilisables uniquement via le logiciel de configuration.
4. Port série
Interface RS232 sur DB9.
Note : Un logiciel spécifique est requis pour utiliser le port RS232.
5. Sélecteur des canaux EtherSound
Ces deux roues codeuses décimales déterminent si l’attribution des canaux EtherSound aux entrées ou aux
sorties d’ES8 est faite localement ou à distance par logiciel de configuration.
6. RJ45 port de control ES
Ce port permet le contrôle et la gestion de votre réseau à l’aide d’un logiciel de gestion d’EtherSound tel
que EScontrol.
7. Mise à la masse
Connectez cette vis de masse au châssis de la baie de montage pour une meilleure mise à la masse de
l’électronique, assurant ainsi une bonne immunité aux interférences électromagnétiques.
8. Alimentation
La prise de courant DOIT être mise à la terre correctement.
27
D
INSTALLATION
Avant de monter les appareils dans une baie
Paramétrages internes
Sur ES881v2, ES1241v2 et ES16161v2, la fréquence d’échantillonnage locale est commutable par cavalier
entre 44.1 kHz et 48 kHz.
La valeur par défaut est de 48 kHz.
Si vous souhaitez modifier ce valeur, veuillez vous référer à l’annexe B de ce manuel.
Note : ces opérations requièrent l’ouverture du coffret et doivent être effectuées par du personnel qualifié uniquement.
Connexion de votre rack EtherSound
Il est recommandé d’établir tous les raccordements avant de mettre l’appareil sous tension.
Alimentation
Avant de brancher le cordon d’alimentation, assurez-vous que:
• le cordon d’alimentation n’est pas endommagé
• la prise de courant utilisée est convenablement mise à la terre.
Comme dans tout autre système audio, il est recommandé de mettre sous tension les différents appareils selon
l’ordre défini par le chemin du signal audio et de les mettre hors tension dans l’ordre inverse.
Ne rien laisser reposer sur le cordon d’alimentation. Tenez le cordon d’alimentation à l’écart de zones de
passage.
Réseau
Le type de câble plus couramment utilisé de nos jours est le CAT5e. Pour plus d’information, veuillez vous
reporter au document “Building ES Networks”, disponible sur notre site web (en anglais).
TM
TM
Les connexions réseau sont réalisées via deux embases Neutrik EtherCon RJ45. La
connexion est très simple : utilisez l’embase marquée “IN” pour connecter le flux
EtherSound descendant (downstream, provenant de la ‘Source d’Horloge’), l’embase
marquée “OUT” pour connecter le flux EtherSound ascendant (upstream).
TM
TM
Les Neutrik EtherCon RJ45 permettent une connexion sure grâce à un système de
verrouillage. Pour déconnecter le câble du dispositif, appuyer sur le cliquet et tirer
simultanément le câble.
Exemple 1 : transmission point à point bi-directionnelle de huit canaux audio
Cette application est très simple avec deux EtherSound ES881v2, ES1241v2 ou ES16161v2.
Connectez un câble Ethernet standard entre le port “OUT” de la première passerelle EtherSound et le port
“IN” de la deuxième passerelle EtherSound. Mettez en concordance les canaux EtherSound sur les deux
appareils (voir l’aide en ligne du logiciel de configuration).
Exemple 2 : architectures plus complexes
La topologie du système peut être en série (daisy chain), en étoile, en anneau, ou une combinaison d’étoile et
de série. Par défaut, le premier dispositif dans un réseau, tel qu’un EtherSound ES881v2, fournit l’horloge
maître pour le réseau entier. Cet appareil est appelé ‘Source d’Horloge’. Vous avez tout de même la possibilité
de synchroniser la Source d’Horloge sur une horloge externe en utilisant l’entrée ‘Word Clock In’ et d’ensuite
fournir cette horloge aux passerelles en aval de la Source d’Horloge en passant par les sorties ‘Word Clock Out’.
Connecter le port “OUT” avec le port “IN” de l’équipement EtherSound suivant.
Répéter cette étape autant de fois que nécessaire. La distance maximale entre deux équipements est de 100 m.
Des commutateurs interconnectés ou des fibres optiques peuvent considérablement augmenter cette distance.
28
EtherSound ES881v2, ES1241v2 & ES16161v2
Passerelles Audio Ethernet
Synchronisation
Plusieurs modes de synchronisation sont possibles avec l’ES881v2/ES1241v2/ES16161v2.
Synchronisation par :
• le réseau (hors mode ‘Source d’Horloge’)
• l’entrée ‘AES In 1’
• l’entrée Word Clock
Si l’équipement est ‘Source d’Horloge’, il fournit l‘horloge au réseau. Il peut être synchronisé sur l‘horloge
interne, ou sur le signal connecté sur l’entrée “AES In 1”, ou sur le signal connecté sur l’entrée Word Clock.
Dans ce dernier cas, il est nécessaire d’activer l’étage de conversion de fréquence matériel (SRC) par le logiciel
de configuration si les signaux AES/EBU d’entrée ne sont pas synchrones de l’horloge Word Clock. De même,
l’insertion du SRC est obligatoire en cas de synchronisation sur l’horloge interne.
Lorsque l’équipement n’est pas en mode ‘Source d’Horloge’, il est synchronisé sur le signal provenant du
réseau :
•
la sortie ‘Word Clock Out’ permet de synchroniser les équipements connectés en entrée ‘AES In 1’.
L’insertion de conversion de fréquence (SRC) n’est alors pas nécessaire.
• si les équipements connectés en entrée AES/EBU ne sont pas synchronisés sur le réseau, l’insertion du
SRC est requise.
Ces paramètres sont configurés à l’aide du logiciel de configuration fourni.
Connexion d’un ordinateur pour la gestion d’un réseau EtherSound
Pour connecter un PC directement à un ES881v2, ce PC doit être équipé d’une carte réseau. Utiliser un câble
Ethernet pour relier la carte réseau au port “IN” de la ‘Source d’Horloge’.
Vous pouvez aussi accéder à la ‘Source d’Horloge’ à travers un réseau Ethernet conventionnel.
Audio
Le brochage utilisé sur les XLR est standard : le point 1 est connecté à la masse, le point 2 au signal positif
(“point chaud”), et le point 3 au signal négatif (“point froid”).
GPIO (entrées/sorties Tout Ou Rien)
ES881v2, ES1241v2 et ES16161v2 sont livrés avec quatre GPIs et quatre GPOs sur prises borniers dont les
contreparties sont fournies. Voir annexe A pour plus de détails.
29
D
Port série (RS232 sur DB9)
Point Description
non connecté
RxD (received data)
TxD (transmitted data)
non connecté
masse des signaux
non connecté
RTS (request to send)
CTS (clear to send)
non connecté
ES881v2, ES1241v2 et ES16161v2 disposent d’un port série RS232 sur DB9 mâle sur le panneau arrière.
Utilisez ce port pour relier tout dispositif compatible. Pour le brochage détaillé, veuillez vous référer au dessin
et au tableau ci-dessus.
Note : Un logiciel spécifique est requis pour utiliser le port RS232.
Réglage à distance au moyen du logiciel de configuration
L’utilisation du logiciel de configuration permet la gestion de toutes les fonctionnalités des dispositifs et
réseaux EtherSound; pour plus de détails sur le logiciel, veuillez vous référer à son aide en ligne.
ES881v2, ES1241v2 et ES16161v2 sont livrés avec un CD-ROM contenant le pilote EtherSound et le logiciel
de configuration de Digigram, EScontrol. Pour procéder à l’installation, il est indispensable d’ajouter d’abord
le pilote EtherSound à votre système. Une fenêtre affiche les instructions que vous devez suivre pour réaliser
cette étape.
Ensuite, lancez setup.exe sur un ordinateur relié à un réseau EtherSound. Un assistant InstallShield vous
guidera lors de la procédure d’installation.
ES881v2, ES1241v2 et ES16161v2 peuvent également être contrôlés par un logiciel de configuration édité par
des partenaires de développement de Digigram.
Aller dans Ajout/Suppression de programmes dans le panneau de configuration pour désinstaller le logiciel.
Mise à jour du micrologiciel
Digigram peut être amené à publier des mises à jour du microcode embarqué. Il peut alors être nécessaire de
mettre à jour vos appareils. Dans ce cas, veuillez vous référer à la documentation respective livrée avec l’outil
de mise à jour du micrologiciel.
30
EtherSound ES881v2, ES1241v2 & ES16161v2
Passerelles Audio Ethernet
SPECIFICATIONS
Configuration
Dimensions
Alimentation
1U 19“ rack: 43.9 x 482.6 x 297.1 mm
100 – 240 VAC, 47-63 Hz
alimentation à découpage, détection automatique de tension
AVERTIS SEMENT: Ne pas ouvrir le bloc d’alimentation. Tensions dangereuses
à l’intérieur. Ne contient aucune pièce que l’utilisateur puisse réparer
Température/humidité
(sans condensation)
En fonctionnement :
Stockage :
Consommation
à 240 V
à 100 V
0 °C – 50 °C / 0% - 95%
-5 °C – 70 °C / 0% - 95%
ES881v2:
0.06 A
0.12 A
ES1241v2:
0.06 A
0.12 A
ES16161v2:
0.07 A
0.14 A
∼3,1 kg (∼6.85 lbs)
Poids net
Entrées/sorties
EtherSound ES881v2 EtherSound ES1241v2 EtherSound ES16161v2
Audio numérique
AES/EBU 3
4 entrées stéréo
4 sorties stéréo
2 entrées stéréo
6 sorties stéréo
8 entrées stéréo
8 sorties stéréo
avec un convertisseur matériel de fréquence d’échantillonnage par entrée,
rapport de conversion 1:3 à 3:1, jusqu’à 96 kHz
110 Ω
Impédance
Fréquence
d’échantillonnage
48 kHz ou 44.1 kHz
Bande passante
à 44.1 kHz
à 48 kHz
10 Hz-21 kHz +/- 0,1 dB
10 Hz-23 kHz +/- 0,1 dB
Connectivité
EtherSound ES881v2 EtherSound ES1241v2 EtherSound ES16161v2
Audio numérique
EtherSound
Control
GPIO (entrées/sorties
Tout Ou Rien)
Port série
4 XLR-3 femelles et
4 XLR-3 mâles
2 XLR-3 femelles et
6 XLR-3 mâles
4 Sub-D 25 femelles
2 EtherCon femelles compatibles RJ45 (connexions “IN”/“OUT”)
14 RJ45
4 entrées optocouplées et 4 sorties relais sur borniers 8 points
1 RS232 sur DB9
Synchronisation
Source d’horloge
Si ‘Source d’Horloge’ dans un réseau EtherSound :
Interne, horloge Word Clock ou sur l’entrée ‘AES IN 1’
Si pas ‘Source d’Horloge’ : réseau EtherSound, horloge Word Clock ou sur
l’entrée AES IN 1 (synchrone avec l’horloge de la ‘Source d’Horloge’)
31
D
ANNEXE A : CONNECTEURS GPIO (TOUT OU RIEN)
ES881v2, ES1241v2 et ES16161v2 possèdent quatre GPIs optocouplés et quatre relais
GPOs. Les GPIs permettent d’envoyer des commandes au logiciel de configuration
EtherSound, les GPOs peuvent être utilisés par le logiciel de configuration EtherSound
pour la télécommande de dispositifs externes.
Les bornes des GPIOs sont marquées 1 à 8 sur le panneau arrière comme illustré.
General Purpose Inputs (GPIs)
Les schémas suivants décrivent la conception de chaque GPI. Le statut d’un GPI peut être soit à “1”, soit à “0” .
Il est lu à “0” dès que le système relié au GPI crée le courant marqué “i” sur le schéma. Sinon, le GPI est lu à
“1”. Les différentes conceptions des GPIs permettent d’établir ce courant de manières multiples, offrant une
grande flexibilité dans la configuration du système afin de satisfaire au mieux vos besoins.
Note: La borne 2 délivrant un potentiel électrique de +5 V et la borne 4 étant mise à la masse, elles peuvent
également être employées dans la configuration d’autres GPIs.
GPI n°1
Le GPI n°1 utilise les bornes 1 & 2
La borne 2 délivre un potentiel électrique de +5 V. Cette borne peut servir de
source pour créer un courant pour les GPI n°3 et GPI n°4.
Commutation du GPI à l’état 0:
Il suffit de relier la borne 1 à la masse pour établir le courant “i”, par exemple
en la reliant à la borne 4.
GPI n°2
Le GPI n°2 utilise les bornes 3 & 4
Commutation du GPI à l’état 0:
Il suffit de relier la borne 3 à la masse pour établir le courant “i”, par exemple
en la reliant à la borne 4.
GPIs n°3 & n°4
Le GPI n°3 utilise les bornes 5 & 6, le GPI n°4 utilise les bornes 7 & 8
Commutation du GPI à l’état 0:
Un courant électrique doit être établi de la borne 6 à la borne 5 (GPI n°3) ou de
la borne 8 à la borne 7 (GPI n°4).
32
EtherSound ES881v2, ES1241v2 & ES16161v2
Passerelles Audio Ethernet
Caractéristiques des optocoupleurs des GPIs
Courant minimum i min de commutation
0,5 mA
Courant maximum i max supporté
50 mA
Règle de calcul de i pour les GPIs n°3 et n°4
i (mA) = Vin - 1,2
3,3
Tension maximale V in supportée
50 Vdc
Tension inverse maximale V in supportée
6V
General Purpose Outputs (GPOs)
Les GPOs des ES8 sont des sorties relais. Ils comportent deux bornes chacun et sont tous configurés de la
même manière. Les bornes 1 & 2 appartiennent au GPO n°1, 3 & 4 au GPO n°2, 5 & 6 au GPO n°3, et 7 & 8
au GPO n°4.
Il répond aux commandes du logiciel de configuration EtherSound envoyés par la Source d’Horloge. S’il est
écrit à “1”, le GPO ferme le relais associé. S’il est écrit à “0”, le GPO ouvre le relais associé.
Caractéristiques des relais des GPOs
Puissance maximale commutable
10 W
Courant maximum commutable
500 mAdc
Courant traversant maximum
1 Adc
Tension maximale commutable
100 Vdc
Durée de vie type
(en commutant la puissance maximale)
10 opérations
33
D
ANNEXE B : PARAMETRAGE DES CAVALIERS INTERNES
Ces paramétrages doivent être effectués uniquement par du personnel qualifié !
Outils requis:
•
•
•
un tournevis Pozidriv n°1
un bracelet antistatique
un petit tournevis plat
Une décharge électrostatique (ESD) peut endommager plusieurs composants sur la carte. Pour
éviter de tels dommages en manipulant la carte, prenez les précautions suivantes:
Mettez le dispositif et tout ce qui entre en contact avec lui au potentiel de masse en présentant
une surface conductrice et des chemins de décharge. Au minimum, observez ces
précautions:
• Débranchez toutes les sources d’alimentation et de signal.
• Placez l’équipement sur une surface de travail conductrice mise à la masse.
• Mettez-vous au potentiel de masse à l’aide d’un bracelet antistatique ou en tenant un objet
mis à la masse.
• Mettez à la masse tous les outils qui entreront en contact avec l’équipement.
• Dévissez les huit vis à tête Pozidriv (quatre sur le dessus,
quatre sur le dessous) dans le sens contraire des aiguilles
d’une montre et ouvrez le coffret.
Localisation des cavaliers sur la carte principale
Face arrière
Face avant
34
EtherSound ES881v2, ES1241v2 & ES16161v2
Passerelles Audio Ethernet
Fréquence d’échantillonnage
Ce cavalier permet la sélection de la fréquence d’échantillonnage d’ES881v2, d’ES1241v2 et d’ES16161v2. La
valeur par défaut est réglée sur 48 kHz. Elle peut être ajustée à 44.1 kHz. Notez que ce réglage est effectif
seulement si l’unité EtherSound est la Source d’Horloge du réseau EtherSound. Dans tout autre cas la fréquence
d’échantillonnage est déterminée par le flux EtherSound entrant (synchronisé sur l’horloge de la Source
d’Horloge) ou synchronisé sur l’horloge Word Clock externe. Des modifications sur des dispositifs autres que
la Source d’Horloge seront ignorées.
35
D
ANNEXE C : ES16161V2
CABLAGE DES ENTREES ET SORTIES NUMERIQUES
Les double-connecteurs Sub-D
Les signaux audio sur les entrées sorties sont disponibles sur les connecteurs Sub-D 25 broches à l'arrière des
équipements. Chaque connecteur est composé de deux banques, chacune d’entre elle recevant quatre signaux
numériques stéréo AES/EBU d’entrée ou de sortie. Les signaux ‘chauds’ (+) sont situés sur les broches
supérieures d’un Sub-D, les ‘froids’ (-) sur les broches inférieures. Le schéma et les tableaux ci-dessous
montrent le câblage par défaut :
Brochage par défaut
Port 1
Pin #
10
11
12
13
Signal
Port 2
Pin #
AES/EBU IN 1+
AES/EBU IN 2+
AES/EBU IN 3+
AES/EBU IN 4+
NC
NC
NC
NC
NC
GND
NC
NC
NC
14
15
16
17
18
19
20
21
22
23
24
25
Signal
AES/EBU IN 1AES/EBU IN 2AES/EBU IN 3AES/EBU IN 4NC
NC
NC
NC
GND
NC
GND
GND
NC
Pin #
10
11
12
13
Signal
NC
NC
NC
NC
NC
GND
NC
NC
NC
Port 3
Pin #
10
11
12
13
36
Signal
Pin #
AES/EBU OUT 1+
AES/EBU OUT 2+
AES/EBU OUT 3+
AES/EBU OUT 4+
14
15
16
17
18
19
20
21
22
23
24
25
NC
NC
NC
NC
NC
GND
NC
NC
NC
Pin #
AES/EBU IN 5+
AES/EBU IN 6+
AES/EBU IN 7+
AES/EBU IN 8+
14
15
16
17
18
19
20
21
22
23
24
25
Signal
AES/EBU IN 5AES/EBU IN 6AES/EBU IN 7AES/EBU IN 8NC
NC
NC
NC
GND
NC
GND
GND
NC
Port 4
Signal
NC
NC
NC
NC
AES/EBU OUT 1AES/EBU OUT 2AES/EBU OUT 3AES/EBU OUT 4GND
NC
GND
GND
NC
Pin #
10
11
12
13
Signal
Pin #
AES/EBU OUT 5+
AES/EBU OUT 6+
AES/EBU OUT 7+
AES/EBU OUT 8+
14
15
16
17
18
19
20
21
22
23
24
25
NC
NC
NC
NC
NC
GND
NC
NC
NC
Signal
NC
NC
NC
NC
AES/EBU OUT 5AES/EBU OUT 6AES/EBU OUT 7AES/EBU OUT 8GND
NC
GND
GND
NC
EtherSound ES881v2, ES1241v2 & ES16161v2
Passerelles Audio Ethernet
Assignation des E/S par défaut
E/S numériques AES/EBU stéréo
Entrées 1 à 4
Entrées 5 à 8
Sorties 1 à 4
Sorties 5 à 8
Port
Port 1 Banque A
Port 2 Banque A
Port 3 Banque B
Port 4 Banque B
Changer l'assignation des groupes d’E/S
Répartition des signaux
Au sein de chaque groupe de quatre entrées ou sorties AES/EBU stéréo les signaux sont attribués comme suit :
E/S numériques
Banque A
Banque B
AES/EBU stéréo
Signal +
Signal Signal +
Signal Entrées/sorties 1 ou 5
14
18
Entrées/sorties 2 ou 6
15
19
Entrées/sorties 3 ou 7
16
20
Entrées/sorties 4 ou 8
17
21
Masse
10, 22, 24, 25
Localisation des connecteurs sur la carte mère et la carte connecteurs
37
D
Nappes de connexion entre carte mère et carte connecteurs
Le schéma représente la configuration par défaut
Signaux
E/S numériques AES/EBU stéréo
Entrées 1 à 4
Entrées 5 à 8
Sorties 1 à 4
Sorties 5 à 8
Port
J11
J4
J71
J10
sur carte connecteurs
sur carte mère
sur carte connecteurs
sur carte mère
Transfert des signaux vers les connecteurs externes
Pour changer l’assignation des groupes de quatre entrées ou quatre sorties, il suffit de changer les connexions
des connecteurs HE sur la carte connecteurs.
Connecteur interne
(carte connecteurs)
J1R
J1L
J2R
J2L
J3R
J3L
J4R
J4L
38
Connecteur externe
Sub-D 25
Port 1 Banque A
Port 1 Banque B
Port 2 Banque A
Port 2 Banque B
Port 3 Banque A
Port 3 Banque B
Port 4 Banque A
Port 4 Banque B
EtherSound ES881v2, ES1241v2 & ES16161v2
Passerelles Audio Ethernet
ANNEXE D : GLOSSAIRE
CANAL AUDIO (AUDIO CHANNEL)
Un canal audio est un signal audio mono simple. Par extension, un canal audio est un des 64 emplacements
de la trame EtherSound, c.à.d. un signal échantillonné à 48 kHz avec une résolution de 24 bits.
COMMUTATEUR (SWITCH)
Elément d’interconnexion de deux segments de réseaux locaux. En recherchant de plus grandes vitesses de
filtrage et de transmission, des efforts ont été faits pour réduire le temps requis pour déterminer si un paquet
doit être filtré ou expédié (’latence’) en examinant seulement l’information d’adresse au début de la trame
Ethernet. Le terme “commutateur Ethernet” est maintenant employé pour les appareils à ports multiples qui
peuvent filtrer et transmettre des paquets quasiment à la vitesse de l’Ethernet (“vitesse du câble”)
indépendamment de la technique utilisée.
DAISY CHAIN (branchement en série)
Se dit d’une topologie de réseau où tous les équipements sont reliés en série.
Source
d’Horloge
GPIO (entrées/sorties Tout Ou Rien)
General Purpose Inputs Outputs. ES881v2, ES1241v2 et ES16161v2 possèdent quatre GPIs et quatre GPOs
chacun. Les GPOs peuvent être configurés pour commander à distance des dispositifs externes. Les GPIs
peuvent être utilisés pour recevoir des commandes de dispositifs externes.
SOURCE D’HORLOGE
Le premier dispositif dans un réseau EtherSound est appelé la ‘Source d’Horloge’, typiquement un ES881v2.
Tout en pouvant être une source audio pour le réseau, la Source d’Horloge envoie les commandes et fournit
l’horloge maître pour la synchronisation des canaux audio.
En tant que Source d’Horloge, l’équipement peut également servir de lien entre le réseau EtherSound et le
logiciel de configuration sur un ordinateur externe relié au port Ethernet IN.
39
D
RING (ANNEAU)
Une topologie en anneau peut être utilisée afin de profiter de la redondance et donc d’augmenter la fiabilité.
Cette topologie doit être considérée comme une extension de la topologie en série, où le dernier appareil est
physiquement relié au premier. La Source d’Horloge prioritaire est désignée par l’administrateur du réseau via
le logiciel de contrôle EtherSound.
Preferred Clock
Source
•
En cas de dysfonctionnement d’un câble, le premier équipement suivant cette défaillance est alors
automatiquement élu Source d’Horloge prioritaire. Le réseau demeure entièrement fonctionnel, il n’y
aucune perte de canal audio.
•
En cas de dysfonctionnement d’un appareil, le même mécanisme de récupération s’applique, mais évidemment – l’audio reliée à l’appareil défectueux est manquant.
STAR (étoile)
L’étoile est une topologie de réseau où tous les dispositifs sont reliés à une même unité (un commutateur dans
l’image suivante) qui gère toutes les communications.
Source
d’Horloge
Switch 1
Switch 2
40
Digigram SA
(Serving Europe, Africa, Middle East, Latin America)
Parc de Pré Milliet
38330 Montbonnot-FRANCE
Tel: +33 (0)4 76 52 55 01
Fax: +33 (0)4 76 52 53 07
E-mail: sales@digigram.com
Digigram Inc.
(Serving North America)
2101 Wilson Boulevard, Suite 1004,
Arlington, VA 22201-USA
Tel: +1 703 875 9100
Fax: +1 703 875 9161
E-mail: input@digigram.com
Digigram Asia Pte Ltd.
(Serving Asia and Australia/Oceania)
350 Orchard Road
#19-07 Shaw House Singapore
238868-SINGAPORE
Tel: +65 6291 2234 - Fax: +65 6291 3433
E-mail: info_asia@digigram.com

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : No
Tagged PDF                      : No
XMP Toolkit                     : 3.1-702
Producer                        : Acrobat Distiller 7.0.5 (Windows)
Company                         : DIGIGRAM
Source Modified                 : D:20070207181412
Creator Tool                    : Acrobat PDFMaker 7.0.7 pour Word
Modify Date                     : 2007:03:13 11:02:48+01:00
Create Date                     : 2007:03:13 09:54:36+01:00
Metadata Date                   : 2007:03:13 11:02:48+01:00
Document ID                     : uuid:f3f7473f-26be-4a79-a799-ff84927b23aa
Instance ID                     : uuid:364f7bd2-72e2-46e1-99c4-9254b0663656
Version ID                      : 3
Format                          : application/pdf
Title                           : ES881v2/1241v2/16161v2
Creator                         : JKR
Subject                         : 
Headline                        : 
Has XFA                         : No
Page Count                      : 42
Page Layout                     : OneColumn
Author                          : JKR
EXIF Metadata provided by EXIF.tools
FCC ID Filing: IGTES8AESV2

Navigation menu