734W Wiegand Interface ModuleDescriptionThe 734W Wiegand Interface Module allows you to add WiFi network access control capability to XR100/XR500 panels using proximity or mag-stripe card readers.  The 734W provides a fast, safe and secure connection to your local WiFi network for AES encrypted TCP communication with the control panel and allows fast verication of user codes presented at the reader for door access.  The 734W operates at 12/24 Vdc from the power supply supporting the magnetic lock or door-strike at the door and provides a 10 Amp Form C relay contact for lock control.  Four input zones are provided to allow connection of nearby burglary devices.  For local annunciation, a programmable speaker and a variety of switched ground annunciators are provided to connect to sounders.  In addition, the 734W provides LEDs to indicate door strike, Wiegand inputs, and power to the module.The 734W provides a keypad programming connection to use a standard DMP LCD keypad for initial WiFi network setup.  Programming can be completed using the keypad or from the XR100/XR500 panel.Mounting the 734WThe 734W ships installed in a decorative, high-impact plastic housing that mounts directly to walls, backboards, or other at surfaces. For easy installation, the 734W housing back and ends have wire entrances.  The bottom contains multiple screw holes for mounting on single-gang switch boxes.  It is recommended to mount the 734W near the protected door.Magnetic Lock and Door Strike WiringYou can control door strikes and magnetic locks by using the Form C relay on the 734W module.  Use an additional power supply to power door strikes and magnetic locks.  Refer to Figures 2 and 3 for wiring information. 12/24 VDC PowerPower to the 734W module can be provided by a Listed 12 or 24 VDC power source connected to the J27 terminal block.  Figure 1: 734W Wiegand Interface ModuleFigure 2: 734W Magnetic Lock Wiring Figure 3: 734W Door Strike WiringINSTALLATION GUIDE
Digital Monitoring Products  734W Installation Guide2NO/C/NC (Dry Contact Relay)The 734W provides a Form C (SPDT) relay for controlling door strikes or magnetic locks.  The three relay terminals  marked NO C NC allow you to connect the device wiring to the relay for module control.  See Figures 2 and 3 for proper door strike and magnetic lock wiring.  The Form C relay draws up to 35mA of current and its contacts are rated for 10 Amps (resistive) at 12/24 VDC.  When connecting multiple locks to the Form C relay, the total current for all locks cannot exceed 10 Amps.  If the total current for all locks exceeds 10 Amps, problems may arise and an isolation relay may be needed. See the Isolation Relay section for information.Install the 333 Suppressor One Model 333 Suppressor is included with the 734W module.  Install the suppressor across the 734W Common (C) and Normally Open (NO) or Normally Closed (NC) terminals. If the device being controlled by the relay is connected to the NO and C terminals, install the suppressor on the NO and C terminals.  Conversely, if the device is connected to the NC and C terminals, install the 333 Suppressor on NC and C terminals.  The suppressor wire is non-polarized.  Install the suppressor as shown in Figure 4.   Isolation RelayThe Form C Relay can control a device that draws less than 10 Amps of current. If a device draws more than 10 Amp of current, or the sum of all devices controlled by the Form C Relay exceeds 10 Amps, an isolation relay must be used. Refer to Figures 5 and 6 for isolation relay wiring.Connection to ReaderThe 734W provides direct 12/24 VDC, 200mA output to the reader on the J9 Red terminal connection.  Figure 7 shows a reader with wire colors Red, White, Green, and Black.  The wire colors may be different for the reader being installed.  Connect the reader wires to J9 terminals 1, 2, 3, and 4.  As shown in Figure 7, the Green wire carries D0, or Data Zero, and the White wire carries D1, or Data One.  The Red wire carries 12/24 VDC, 200mA power limited output and the Black wire is ground.Status LEDsThe 734W provides two status LEDs. See Figure 1 for locations of the LEDs.•  The Red LED turns on for the duration of the door strike.  •  The Yellow LED turns on for one second to indicate a Wiegand read.  •  The Green LED is constant to indicate power.Figure 6: Isolation Relay with Door StrikeFigure 4: Model 333 Installation on the 734W ModuleFigure 5: Isolation Relay with Magnetic LockFigure 7: Card Reader Wiring
734W Installation Guide   Digital Monitoring Products3Zone TerminalsTerminals 5-11 on J9 connect grounded zones 1 through 3.  These zones have a grounded side and cannot be used for re-initiating devices.  Zones 2 and 3 can also be used for access control with Zone 2 providing a bypass option and Zone 3 providing Request to Exit functionality.  Zone 4 terminals provide a non-powered Class B, Style A zone. Use the supplied, DMP Model 311 1K Ohm End-of-Line resistors on each zone.  Refer to the panel programming guide for programming instructions.Zone # Recommended Device Residential Fire Devices?1Any burglary device No2Door Contact No3REX (PIR or Button) No4Any device YesAnnunciator HeaderThe 4-pin J26 header located on the far right of the circuit board is used to wire the Armed Status, Remote Annunciation, and the Remote LED Control. The open collectors will supply a ground for a maximum current of 50mA @ 30 VDC. Connect a Model 300 4-wire harness to the 4-pin header for connection of the following indicators:--AS (Armed Status)Armed Status provides an unsupervised switched ground for a visual or audible armed status indicator that turns on when the burglary areas are armed, such as SYSTEM ON or ALL SYSTEM ON.  Connect the wire from the 4-wire harness to an Armed Status output. --RA (Remote Annunciation)Remote Annunciation provides an unsupervised switched ground for a remote annunciator that turns on when the Model 734W on-board piezo turns on.  Connect the wire from the 4-wire harness to a remote annunciator.  The remote annunciator silences when the RA restores.  The remote annunciator (RA) switched ground will operate even if the speaker is programmed not to operate. --LC (Remote LED Control)Remote LED Control provides an unsupervised switched ground for a visual indicator that turns on when the Model 734W relay activates.  Connect the wire from the 4-wire harness to an LED.  The LED turns on for the duration the door strike relay is on. HID readers optionally provide a connection for LED reader control.Auxiliary Outputs 1 & 2The 734W controls Auxiliary Outputs 1 and 2 when the Activate Zone 2 Bypass programming option is enabled and the Zone 2 Bypass Time is set. When the door contact (Zone 2) is opened while the door strike is activated, the Zone 2 Bypass Time starts. If the door has not closed at the end of the timer, Aux Output 1 is turned on and the timer starts again. If the door is still open at the end of the second timer, Aux Output 2 is turned on. Aux Outputs 1 and 2 turn off when the door contact  is closed. Use the Model 431 Relay Harness for connection of Output 1 and Output 2 as shown in Table 1.Reset HeaderThe reset header is located just above and to the right of the WiFi network connector (see Figure 1) and is used to reset the 734W module. To reset the module when rst installing the system, install the reset jumper before applying power to the module. After connecting the power, remove the reset jumper. To reset the module while the system is operational, for example, prior to reprogramming, install the reset jumper without powering down the system. Remove the reset jumper after one or two seconds.PROG (Programming)The 734W module is programmable from a 32-character keypad set to address one. For 12 Volt applications, connect the keypad to the module using a Model 330 4-wire harness.  For 24 Volt applications, connect the keypad to the module using the included WR-0235 4-wire programming harness with in-line resistor. Do not connect a keypad using a Model 330 harness if using a 24 volt power supply! Damage to the keypad could occur.While programming the 734W module with a keypad, advance to the next programming option by pressing the CMD key.  Return to the previous programming option or erase an incorrect entry by pressing the Back Arrow key.  Make a selection by pressing the Select key below the option you wish to select.  While in programming mode no 734W communication with the panel can occur.Figure 8: 734W Zone TerminalsRemote Audible AnnunciatorArmed Status OutputOutput 2Output 1Remote LED ControlFigure 9: 734W Annunicator OutputsForm C Relays (J2)Output Color Code–Model 431 HarnessOutput 2   N/O   Orange/WhiteOutput 2  Com  White/GrayOutput 2  N/C  Violet/WhiteOutput 1  N/O  OrangeOutput 1  Com  GrayOutput 1  N/C  VioletTable 1: Harness Wiring
734W Installation Guide   Digital Monitoring Products4 Version Display When you connect the keypad to the 734W module, the version number and release      date display.•  Press keys 1, 2, 3, or 4 then the CMD key to show zone status of that zone. •  Press CMD key to enter the Diagnostic Menu.•  Press 6653 (PROG) then CMD to enter the Programming Menu.  Zone Status Display The status of the entered zone number displays. To display another zone, enter the      zone number followed by the CMD key.  Diagnostic Menu Select YES to display the Panel Communication Connect Status display.  Select NO to      return to Version Display. Connect Status To display the connection status of the 734W to the panel, select any top row key. Not Connected: The 734W cannot connect to the panel on the WiFi network. Bad Passphrase: The passphrase programmed in the 734W device does not match the      passphrase programmed in the panel. Device Not Programmed: The device number programmed in the 734W is not programmed as a    Device Number in the panel. Duplicate Device: There is another device on the WiFi network with the same device number. Transmit Time XXX: The speed in milliseconds in which the last message was sent and received    between the 734W and the panel. Programming Menu Press the CMD key to enter programming and display initialization options.    Initialization Options  These options can set the 734W module programming memory back to factory defaults        in preparation for programming. Press any select key to enter the initialization menu.   Initialization Communications Select YES to initialize the communication options back to factory defaults.  Select NO to    leave communication options unchanged. InitializeConrmOption After selecting YES to clear the Communication settings, the 734W displays SURE?  YES  NO    for conrmation to clear the memory.  This is a safeguard against accidentally erasing the    programming.  No memory is cleared from the programming until you answer YES to the    SURE? option.  Selecting NO leaves communication options unchanged.  Initialization Access Select YES to initialize the Access Options back to factory defaults.  Select NO to return to    the INITIALIZATION menu.    INITIALIZATION SURE?           YES  NO InitializeConrmOption After selecting YES to clear the Access Options, the 734W displays SURE?  YES  NO for      conrmation to clear the memory.  This is a safeguard against accidentally erasing the      programming.  No memory is cleared from the programming until you answer YES to the SURE?    option.  Selecting NO leaves communication options unchanged.734W   COMMUNICATION  Communication Menu Press any select key to enter the Communication menu. Press the CMD key to advance to    the Access Options menu. Press the back arrow to display the 734W Initialization menu.    INITIALIZATIONACCESS?      NO   YES734WVER  vvv  mm/dd/yy 734W DOOR ZONE: 2   -OPEN 734W REX ZONE: 3   -SHORT CONNECT  STATUS NOT  CONNECTED CONNECT  STATUS BAD  PASSPHRASE CONNECT  STATUS DEVICE NOT PROG CONNECT  STATUS XMIT TIME xxx mSMENU?        NO  YES CONNECT  STATUS DUPLICATE DEVICE  734W ZONE: 1   -OKAY  CONNECT  STATUS    INITIALIZATION  COMMS?    NO   YES  734W    INITIALIZATION   734WPROGRAMMERINITIALIZATION SURE?           YES  NO
734W Installation Guide   Digital Monitoring Products5 734W  DEVICE  NO:    7            734W Device Number Enter a device number from 2-16 for the 734W. The device number must also be      programmed as a device in the panel. Default is 7. 734W DHCP?      NO     YES  734W DHCP Select YES (fourth select key) to use dynamic IP address information for the 734W IP      Address, Subnet Mask, and Gateway Address. Select NO (third select key) to enter static    IP information. 734W  IP  ADDRESS:  192.168.0.201  734W IP Address Enter the IP address of the 734W. Default is 192.168.0.201. SUBNET  MASK:    255.255.255.0          Subnet Mask Enter the local subnet mask assigned to the  734W. Default is 255.255.255.0 GATEWAY ADDRESS:  192.168.0.1          Gateway Address Enter the local gateway address of the 734W. Default is 192.168.0.1 PANEL IP ADDR:  0.0.0.0         Panel IP Address Enter the IP address of the panel. Default is 0.0.0.0. Note: This IP address must match the address programmed in the panel at the Local IP      Address prompt in Network Options.  The DHCP programming in the panel must be set to NO. PANEL IP PORT:  2002            Panel IP Port Enter the port number that the 734W uses to send communication to the panel.  This must    be the same port that is programmed in 734W Listen Port in Network Options        programming of the panel. 734W  PASSPHRASE              734W Passphrase Enter an 8 to 16-character alphanumeric Passphrase to encrypt communication with the    panel.  The 734W Passphrase must match the 734W Passphrase entered in Network Options    programming of the panel.  The Passphrase is blank by default. Note: A passphrase is required for communication to occur with the panel.   734W  ACCESS    OPTIONS        Access Options Press any select key to enter the Access Options menu. Press the CMD key to advance to the    Stop prompt. Press the back arrow to display the Communication menu.ACTIVATE ZONE 2BYPASS?  NO   YES  Activate Zone 2 Bypass Select YES to activate the Zone 2 Bypass operation.  Selecting NO allows standard zone    operation on Zone. Default setting is NO. If the door being released by the 734W module is    protected (contact installed), you can provide a programmable bypass entry/exit timer by    connecting its contact wiring to the 734W module Zone 2.  When the on-board Form C relay    activates and the user opens the door connected to Zone 2, the zone is delayed for the     number of seconds programmed in ZONE 2 BYPASS TIME allowing the user to enter/exit during    an armed period. If Zone 2 does not restore (door closed) within the programmed time, the piezo sounds  every    other second during the last ten seconds.  If Zone 2 restores prior to the end of the      programmed time, the piezo silences.  If the zone does not restore before the programmed    time, the 734W ends the bypass and indicates the open or short zone condition to the panel. ZONE 2 BYPASSTIME:   40  Zone 2 Bypass Time Enter the number of seconds to elapse before the Bypass Timer expires.  Range is from 20    to 250 seconds.  Press any top row select key to enter the number of seconds.  If the door    remains open when the timer expires a zone open/short is sent to the panel for Zone 2.     The default is 40 seconds. Figure 10 shows how the Bypass option works. 5 SecondStrike40-Second Zone 2 Bypassentry/exit timer.10 seconds beforethe bypass time expires,the device beeps ifthe door is still open.End of timer.40SecondsA zone open/short is indicated if the doorremains open.Figure 10: Zone 2 Bypass Timeline using default time
734W Installation Guide   Digital Monitoring Products6RELOCK ON ZONE 2CHANGE?  NO      YES  Relock on Zone 2 Change? Selecting YES turns the relay off when Zone 2 returns to normal during the bypass. Selecting    NO leaves the relay on when Zone 2 faults to an open or short condition during bypass.    Turning off the relay at Door Closed allows a long strike time to be automatically ended and    relocks the door. The default is NO.  ACTIVATE ZONE 3REX?  NO YES Activate Zone 3 Request to Exit  Selecting YES activates the Zone 3 Request to Exit (REX) option.    Selecting NO allows standard zone operation on Zone 3.  Default setting is NO.   You can  connect a PIR (or other motion sensing device) or a mechanical switch to Zone 3    to provide REX capability to the system.    When Zone 3 shorts, the on-board Form C relay activates for the programmed number of    seconds (see Zone 3 REX Strike Time).  During this time, the user can open the protected    door to start the programmed Zone 2 Bypass entry/exit timer.  After the programmed     number of seconds, the relay restores the door to its locked state.  The 734W module provides a bypass-only option for REX on Zone 3.  When Zone 3 OPENS    from a NORMAL state, only a bypass occurs: the on-board relay does not activate.  This    bypass-only option uses two methods of REX.  The rst REX device provides the programmed    bypass entry/exit timer.  The second REX, or manual device such as a door knob, unlocks    the door.    An example of the shunt-only conguration is a door to an ofce that is locked 24 hours    a day.  Users pass a REX motion detector positioned by the door to begin the programmed    exit timer.  Within the programmed number of seconds the user must then manually      activate a second device, such as a REX device or manual door knob, to unlock the door.  If    the door is opened after the programmed number of seconds, an open condition is indicated    to the panel. ZN  3  REX  STRIKETIME:   5  Zone 3 REX Strike Time Enter the number of REX seconds to elapse.  Range is from 5 to 250 seconds.  Press any    select key to enter the number of seconds.  The default is 5 seconds. ACTIVATE ONBOARDSPEAKER? NO    YES  Activate Onboard Speaker Select YES to enable the onboard speaker for local annunciation, such as alarm and trouble    annunciations.  Select NO to turn the speaker off for all operations.  This does not affect    remote annunciator open collector (RA) operation. The default is NO.    Card Options Typically, an access card contains data bits for a site code, a user code, and start/stop/    parity bits.  The starting position location and code length must be determined and programmed into the 734W Module.  Select DMP to indicate the reader sends a 26-45 bit data string.  To select the DMP option,  press the rst Select key under DMP.   Default is DMP.Select CUSTOM if using a non-DMP card or user code length of 6 to 10 digits. Select ANY to allow all card reads to activate the door strike relay. The door strike relay is   activated for the length of time programmed in ZN 3 REX TIME. No user code information is   sent to the panel. Note: When set to DMP, the 734W converts 17 bits of the 26 to 45-bit data string into a    5-digit number.   WIEGAND CODELENGTH:   26 CustomCardDenitions When using a custom product, enter the total number of bits to be received in Wiegand    code including parity bits.    Press any top row Select key to enter a number between 0-255 to equal the number of bits.     Default is 26 bits. Site Code Position Enter the site code start position in the data string.  Press any Select Key to enter a number    between 0-255.  Default is 1.  Press the COMMAND key to save the entry.SITE CODEPOSITION:    1CARD OPTIONS:DMPCARD OPTIONS:DMP   CUSTOM  ANY01110101101101010001100111First BitReceivedPosition = 0Site CodePosition = 2Length = 8User CodePosition = 10Length = 16Last BitReceivedPosition = 25In this example the Wiegand Code Length = 26 bits.Figure 11: HID 26-bit Weigand Data Stream Bit Location
734W Installation Guide   Digital Monitoring Products7SITE CODELENGTH:     8 Site Code Length Enter the number of Site Code bits used.  Press any Select Key to enter a number between    1-16.  Default is 8.  Press the COMMAND key to save the entry.USER CODEPOSITION:  9  User Code Position Dene the User Code start bit position.  Press any Select Key to enter a number between    0-255.  Default is 9.  Press the COMMAND key to save the entry.USER CODELENGTH:   16  User Code Length Dene the total number of User Code bits used.  Press any Select Key to enter a number    between 1-255.  The default is 16.REQUIRE SITECODE:   NO      YES  Require Site Code Press the top row Select key under YES to use a site code and press the COMMAND key to    view the site code entry display. In addition to User Code verication, door access is only    granted when any one site code programmed at the SITE CODE ENTRY option matches the    site code received in the Wiegand string.  Site Code Display You can program up to eight ve-digit site codes.  Site code range is 1-65535.    SITE CODE 1 displays rst. Any previously programmed site code displays.  Default is 127.     To change the site code, press a select key, then enter the new code. Press the COMMAND    key to save and to display the next site code.  Site Codes 2-8 default to blank. NO. OF USER CODEDIGITS:    5  Number of User Code Digits The 734W module recognizes user codes from one to ten digits in length.  Press any top row    Select key to enter a user code digit length between 1-10 digits.  This number must match the    user code number length being programmed in the panel. Default is 5.    All bits are read and converted into a decimal number string. The number string is left    padded with '0' if needed for long user code lengths. When selecting '4' the right digit is    dropped and the next four sent.   Example:  # decoded      1234567    10 digits   0001234567 5 digits    34567 4 digits    3456    No Communication with Panel This option denes the relay action when communication with the panel has not occurred    for ve seconds.  Default is OFF. Press any top row Select key to change the default relay   action.   Choose the action required when the 734W cannot establish communication with the panel:  Press the rst Select key to choose OFF (Relay Always Off) — The relay does not turn on    when any Wiegand string is received.  OFF does not affect any REX operation.  If      communication is lost during a door strike, relay remains on for the door strike duration,    but turns off at the end of the door strike timer.  Press the second Select key to choose SITE (Accept Site Code) — Door access is granted    when the Wiegand site code string received matches any site code programmed at SITE    CODE 1-8.  For details refer back to the REQUIRE SITE CODE option.  Press the third Select key to choose ANY (Any Wiegand Read) — Door access is granted when   any Wiegand string is received.    Press the fourth Select key to choose ON (Relay Always On) — The relay is always on.    Press the COMMAND key to display the next action.    Press the rst Select key to choose LAST (Keep Last State) — The relay remains in the same    state and does not change when communication is lost. If communication is lost during a    door strike, the relay remains on for the door strike duration, but then returns to it's last    state prior to doing the door strike.734WSTOP Stop Press any select key to start the stop routine. When programming in complete, the Version    displays and the keypad can now be removed.FCC InformationElectronic EmissionThis device complies with CFR47 Part 15 of the FCC rules. Operation is subject to the following two conditions:(1) This device may not cause harmful interference, and(2) this device must accept any interference received, including interference that may cause undesired operation. NO COMM WITH PNL OFF  SITE  ANY  ON SITE CODE 1: (1 - 65,535)    127 SITE CODE 2: (1 - 65,535)    - SITE CODE 8: (1 - 65,535)    - NO COMM WITH PNL LAST
LT-1213 © 2012 Digital Monitoring Products, Inc.12055INTRUSION   •   FIRE   •  ACCESS   •  NETWORKS2500 North Partnership Boulevard800-641-4282www.dmp.comMade  in  the  USA Springeld,  Missouri  65803-8877FCC Frequency InterferenceThis equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to CFR47 Part 15.  These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a residential environment, not withstanding use in commercial, business and industrial environment.  This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.  There is no guarantee that interference will not occur in a particular installation.  If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: - Reorient or relocate the receiving antenna.- Increase the separation between the equipment and receiver.- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.- Consult the dealer or an experienced radio/TV technician for help.Changes or modications to this equipment not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.FCC Radiation ExposureTo comply with FCC Radio Frequency exposure requirements in section 1.1307, a minimum separation distance of 20 cm. is required between the antenna and all occupational persons, and a minimum separation distance of 20 cm. is required between the antenna and all public persons.Antenna InstallationWARNING: It is installer’s responsibility to ensure that when using the authorized antennas in the United States (or where FCC rules apply); only those antennas certied with the product are used.  The use of any antenna other than those certied with the product is expressly forbidden in accordance to FCC rules CFR47 part 15.204.  The installer should congure the output power level of antennas, according to country regulations and per antenna type.  Professional installation is required of equipment with connectors to ensure compliance with health and safety issues.Industry Canada InformationUnder Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum (or lesser) gain approved for the transmitter by Industry Canada.  To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for successful communication.This radio transmitter (identify the device by certication number, or model number if Category II) has been approved by Industry Canada to operate with the antenna provided with the maximum permissible gain and required antenna impedance.  Antenna types not included, having a gain greater than the maximum gain indicated for that type, are strictly prohibited for use with this device.This device complies with Industry Canada Licence-exempt RSS standard(s). Operation is subject to the following two conditions:(1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device.Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio exempts de licence. L’exploitation est autorisée aux deux conditions suivantes : (1) l’appareil ne doit pas produire de brouillage, et (2) l’utilisateur de l’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en compromettre le fonctionnement.SpecicationsPrimary Power  8.5 VDC to 28.5 VDCCurrent Draw   Standby 100mA    + 1.6mA per active zone Alarm   100mA    + 10mA with Annunciator ON    + 2mA per faulted zone Form C Relay  35mA at 12/24 VDC  Zones  5 VDC, 2mA maxDimensions  4.5” W x 2.75” H x 1.75” DCompatibilityXR100/XR500 Series panelsAccessoriesProximity Readers PP-6005B ProxPoint® Plus Proximity Reader MP-5365  MiniProx™ Proximity Reader PR-5455 ProxPro® II Proximity Reader MX-5375 MaxiProx® Proximity Reader TL-5395  ThinLine II® Proximity ReaderProximity Credentials 1306P   DMP Prox Patch 1306PW   Prox Patch™ 1326   ProxCard II® Card 1346   ProxKey II® Access Device 1351   ProxPass® 1386   ISOProx II® Card Listings and Approvals  FCC Part 15 ID: CCKPC0110  Industry Canada ID: 5251A-PC0110